Utilitech PPSU33 Manual de usuario

Tipo
Manual de usuario
AB13579 1
ITEM #0435062
AUTOMATIC
SUBMERSIBLE PUMP
MODEL: PPSU33
Español p. 9_
PACAKGE CONTENTS
Part
Description
Quantity
A
Pump
1
B
Adaptor
1
ATTACH YOUR RECEIPT HERE
Serial Number ______________________ Purchase Date___________________________
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-866-994-4148, 8 a.m. 8 p.m., EST, Monday Friday.
A
B
Lowes.com
2
Lowes.com
TABLE OF CONTENTS
Specifications ................................................................................................................................... 2
Construction ..................................................................................................................................... 2
Safety information ............................................................................................................................ 3
Performance .................................................................................................................................... 4
Preparation ...................................................................................................................................... 5
Installation instructions ..................................................................................................................... 5
Operation instructions ...................................................................................................................... 6
Airlock .............................................................................................................................................. 6
Care and maintenance ..................................................................................................................... 7
Troubleshooting ............................................................................................................................... 7
Warranty .......................................................................................................................................... 8
SPECIFICATIONS
Power supply required ............................................................................................ 115 V, 60 Hz
Water temperature range ................................................................................. Max. 77°F (25°C)
Operation position .......................................................................................................... Vertical
Individual branch circuit required ..................................................................... 10-amp minimum
Operating water depth - beginning minimum .......................................... approximately 1-1/2 in.
Ending water level - max ........................................................................... approximately 1/4 in.
Discharge connection ......... 3/4 in. garden hose thread or 1-1/4 in. hose with included adaptor,
1 in. garden hose if attaching directly to the pump
Discharge hose diameter .............................................................................3/4 in. minimum I.D.
Discharge hose length ............................................. 50 ft. maximum recommended hose length
Motor ............................................ Permanent Split Capacitor, with thermal overload protection
Power cord .......................................................................................... SJTW, 18AWG/3C, 10 ft.
CONSTRUCTION
Motor housing ...........................................................................................Flame retardant nylon
Volute (Intake screen)..................................................................................... Reinforced nylon
Impeller ...................................................................................... Glass reinforced thermo plastic
3
Lowes.com
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install
the product. If you have any questions regarding the product, please call customer service at
1-866-994-4148, 8 a.m. - 8 p.m., EST, Monday - Friday.
WARNING
The pump will only turn on when water reaches approximately 1-1/2 in., and will turn off
automatically at approximately 1/4 in. of water remaining. Place the pump in the lowest
possible location so that water will flow toward the pump and turn the pump on.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do
not use in the presence of flammable or explosive vapors. Using this pump with or near
flammable liquids can cause an explosion or fire, resulting in property damage, serious
personal injury and/or death.
Always disconnect the pump from its power source before inspection.
Do not stand in water when the pump is connected. Do not handle pump with wet hands.
Do not touch the pump housing while it is operating, as the pump may be HOT and can cause
serious skin burns.
Do not disassemble the motor housing. This pump has NO repairable internal parts, and
disassembling may cause an oil leak or dangerous electrical wiring issues.
CAUTION
This submersible utility pump is designed for portable applications. It can drain or remove
water from the following: pits, sinks, window wells, basements, swimming pool covers, boats,
low spots in yards, or other flooded areas. This pump has not been tested or approved for use
in swimming pools or in salt-water marine areas.
This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free
service for many years when properly installed, maintained, and used. However, inadequate
electrical power to the pump, or blockage by ice, dirt, or debris may cause the pump to fail,
potentially bringing about additional water damage. To minimize the potential for water damage
due to pump failure, please read the section of this manual regarding common pump problems
and remedies or call 1-866-994-4148.
This pump is not designed to function as a permanently installed sump pump. It is also not
engineered to be run continuously as a “fountain” or “waterfall” pump. Because this pump has
an oil-filled motor, it should NOT be used in water containing fish. The pump should be used
with a 3/4 in. or larger inside diameter garden hose, or use with hose kit (Item #0313726).
For safety, the pump motor has an automatically resetting thermal protector that automatically
will turn off the pump if it becomes too hot. Overuse of this feature will damage the pump
and void the warranty.
Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow
the pump to operate normally. If the pump is plugged in, it may restart unexpectedly.
4
Lowes.com
Additional Safety Precautions
1. Know the pump applications, limitations, and potential hazards.
2. Make certain the electrical power source is adequate for the requirements of the pump.
3. ALWAYS disconnect the power to the pump and drain all water from the system before
servicing.
4. Secure the pump on a solid base to keep the pump vertical and above mud and sand during
operation to maximize pumping efficiency and prevent clogging and premature pump failure.
5. Secure the discharge hose before starting the pump. Pump torque may cause an unsecured
discharge hose to “whip”, possibly causing personal injury and/or property damage.
6. Before using the pump, check hose for holes or excess wear, which could cause leaks, and be
sure hose is not kinked or making sharp angles. A straight hose allows the pump to move the
greatest amount of water quickly.
7. Check that all hose connections are tight to minimize leaks.
8. Connect the pump DIRECTLY to a grounded, GFCI outlet.
9. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present
a life-threatening safety hazard if the insulation becomes damaged or the connection ends fall
into water.
10. Make certain the electrical circuit to the pump is protected by a 10-amp or larger fuse or circuit
breaker.
11. Periodically inspect pump and system components, to be sure pump inlets are free of mud,
sand, and debris. DISCONNECT PUMP FROM THE POWER SUPPLY BEFORE
INSPECTING.
12. Wear safety glasses at all times when working with pumps.
13. Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the
workplace, the Occupational Safety and Health Act (OSHA).
14. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an
approved 3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND
PIN UNDER ANY CIRCUMSTANCES. The 3-prong plug must be directly inserted into a
properly installed and grounded 3-prong, grounding-type receptacle. Do not use pump with a
2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a
GFCI outlet) installed in accordance with the National Electrical Code and local codes and
ordinances. All wiring should be performed by a qualified electrician.
15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking
the cord. Do not use damaged or worn cords.
PERFORMANCE
Model
HP
5 ft.
10 ft.
15 ft.
20 ft.
25 ft.
Maximum Lift
PPSU33
1/3
21
17
12
7
3
28 ft.
For best performance, the maximum recommended hose length is 50 ft. The pumping capacity or
water flow rate of any pump depends on several factors. The larger the inside diameter and the
shorter the length of hose, the less pressure that is lost (or the larger the flow rate). The maximum
pressure produced by this pump is about 13 PSI. If the hose runs uphill or is extra-long, use a
larger diameter hose or rigid pipe.
5
Lowes.com
PREPARATION
WARNING: Always use handle to lift pump. Never use power cord to lift pump. To avoid
skin burns, unplug and allow time for the pump to cool after periods of extended use.
Before beginning assembly of product, make sure all parts are present. Compare parts with
package contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated Assembly Time (New installation): 5 minutes
Materials Required for Assembly (not included): Garden Hose or Hose Kit (Item #0313726)
The pump should rest on a level, solid base.
Do not suspend the pump by the discharge hose or power cord.
Keep the pump inlet screen clear.
Do not install pump directly on sand or dirt. A minimum water level of 1-1/2 in. is required to
prime the pump.
INSTALLATION INSTRUCTIONS
1. Attach the included adaptor (B) to the threads of the pump (A).
Note: The adaptor (B) has a built-in check valve. The use of this
adaptor will prevent the backflow of water into the pump (A).
2. Connect either a 3/4 in. garden hose to the threads of the adaptor (B)
or clamp a 1-1/4 in. hose kit (Item #0313726, sold separately) to the
barbs of the adaptor (B).
Note: Be sure the garden hose end has a rubber washer to minimize
water leaks.
WARNING: Secure the discharge hose before plugging in the pump.
Pump torque may cause an unsecured discharge hose to “whip,
possibly causing personal injury and/or property damage.
2
B
B
A
A
6
Lowes.com
OPERATION INSTRUCTIONS
NOTICE: Make certain you unwind the garden hose completely. Kinks in the hose will restrict the
pump, preventing it from priming, which is the first step to pumping water. The water level must be
at approximately 1-1/2 in. for the pump to prime and operate.
1. Plug the pump (A) into a 115 volt GFCI power outlet.
WARNING: Do not let plug fall in water and do not stand in
water while the pump (A) is plugged in.
Automatic Operation
The pump (A) will only turn on if there is approximately 1-1/2 in. of water around the pump.
Water must make contact with the sensor probes of the pump in order for it to turn on.
When the pump (A) removes water down to approximately 1/4 in., the pump will run for an
additional 30 seconds and then turn off.
o Note: If the pump (A) does not turn off, remove the pump and check to make sure that
water or other debris is not still contacting the sensor probes.
The pump can remain plugged in and will automatically turn back on when water reaches
approximately 1-1/2 in. again.
AIRLOCK
This pump (A) is a centrifugal utility pump, designed to efficiently
remove water. However, it cannot move air. If air is trapped
inside the pump (a condition called “airlock”), the pump
cannot pump water out even though the pump is completely
submerged. This pump has an anti-airlock hole (see Fig. 1). Air
flows out through the anti-airlock hole, eliminating the airlock so that
the pump can operate properly. If debris blocks the anti-airlock hole,
unplug the pump, clean out the anti-airlock hole and restart the
pump. Alternately, drain the water out of the garden hose, keep
the end of the hose out of the water, and plug in the power
cord, restarting the pump.
CAUTION: This hole is for anti-airlock purposes. Leakage of air
or water is NORMAL. DO NOT BLOCK THIS HOLE!
A
Anti-
airlock
hole
On at 1-1/2 in.
Off at 1/4 in.
7
Lowes.com
CARE AND MAINTENANCE
Periodically unplug the pump, making certain your hands are dry, and you are not standing in
water. When the power is disconnected, inspect the pump inlets and remove all debris, then plug
pump back into the grounded (GFCI) outlet.
1. To clear a pump clogged with debris, first, UNPLUG
PUMP from electrical power. Then, referring to Fig. 1,
unscrew the stainless screws (1) and remove the
screen/volute (2) and the seal gasket (3) (NOTE: gasket
will likely remain connected to pump; if so, only remove
if it needs to be cleaned). Use a wrench (not included)
to remove the nut (4), then gently pry off the impeller
(5). Remove debris from around the motor shaft and
on/under the impeller (5). Reassemble.
Cleaning the sensor probes
Rarely, it is possible for the sensor probes to be covered with debris, and this can affect the
automatic performance of the pump. If the pump is not turning on when approximately 1-1/2 in.
of water is present or is not turning off when water has been removed, unplug the pump and
remove from the water. Remove the two stainless screws (6) and remove the sensor probe
housing (7). There will be metal probes inside this housing. Gently clean off these probes with
a small brush (not included) and dry the probes. Reassemble.
TROUBLESHOOTING
If you have any questions regarding the product, please call customer service at 1-866-994-4148,
8 a.m. - 8 p.m. (EST), Monday Friday.
Note: Do not disassemble the motor housing. This motor has NO repairable internal parts
and disassembling may cause an oil leak or dangerous electrical wiring issues.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Pump does
not start or
run
1. Probes covered in debris
2. Blown fuse/tripped
breaker
3. Plug disconnected
4. Thermal overload
5. Corroded plug
6. Motor failed
1. Clean sensor probes (See “Care & Maintenance”)
2. Replace fuse/reset breaker
3. Secure plug
4. Unplug the pump for 30 minutes, then plug in
5. Clean plug prongs
6. Call 1-866-994-4148
Pump
cannot
pump
water out
1. Screen blocked
2. Hose kinked or coiled
3. Airlock
4. Hose diameter too small
5. Hose length too long
6. Impeller loose on shaft
7. Impeller broken
1. Clean screen
2. Straighten hose
3. Clean airlock release feature
4. Use larger diameter hose
5. Use shorter hose
6. Reassemble impeller (See “Care & Maintenance”)
7. Call 1-866-994-4148
1
4
3
2
5
7
6
8
Lowes.com
WARRANTY
This product is warranted against manufacturing defects for a period of 12 months from the date of
purchase. Any misuse, abuse, or modification automatically voids this warranty. The distributor will
repair or replace the pump if, in its sole determination, the pump failed due to defects in materials
or workmanship.
WARRANTY EXCLUSIONS
1. Neither the distributor nor the store that sold this pump shall in any event be liable for any labor
or similar expenses incurred in removing or repairing this pump.
2. The distributor specifically disclaims any implied warranties of merchantability and fitness for a
particular purpose.
3. In no event shall the distributor be liable for consequential, incidental, or special damages
resulting from or related in any manner to any distributor components or accessories.
4. The distributor disclaims all liability for improper installation or improper use of this product.
Some states do not allow the exclusion or limitation of incidental or consequential
damages. The above limitations and exclusions may not apply to you. In addition to the
rights given you by this warranty, you may also have other rights which vary from state to
state.
For warranty claims, DO NOT RETURN PUMP TO THE STORE!
Call our customer service department at: 1-866-994-4148, Monday Friday, 8:00 a.m.
8:00 p.m., EST.
Printed in China
Utilitech® is a registered trademark
of LF, LLC. All Rights Reserved.
9
Lowes.com
ARTÍCULO
#435062
BOMBA SUMERGIBLE
AUTOMÁTICA
MODELO: PPSU33
CONTENIDO DEL PAQUETE
Pieza
DescripciÓn
Cantidad
A
Bomba
1
B
Adaptador
1
ADJUNTE SU RECIBO AQUí
Número de serie______________________ Fecha de compra ________________________
¿Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, llame a nuestro
Departamento de Servicio al Cliente al 1-866-994-4148, de lunes a viernes de 8 a.m.
a 8 p.m., hora estándar del Este.
A
B
10
Lowes.com
íNDICE
Especificaciones ............................................................................................................................ 10
Fabricación .................................................................................................................................... 10
Información de seguridad............................................................................................................... 11
Rendimiento ................................................................................................................................... 13
Preparación .................................................................................................................................... 13
Instrucciones de instalación ........................................................................................................... 13
Instrucciones de funcionamiento .................................................................................................... 14
Bloqueo de aire .............................................................................................................................. 15
Cuidado y mantenimiento .............................................................................................................. 15
Solución de problemas .................................................................................................................. 16
Garantía ......................................................................................................................................... 16
ESPECIFICACIONES
Suministro de electricidad necesario ...................................................................... 115 V, 60 Hz
Rango de temperatura de agua ....................................................................... Max. 25°C (77°F)
Posición de operación .................................................................................................... Vertical
Se requiere circuito de derivación individual ............................................... Mínimo 10 amperios
Profundidad de agua en funcionamiento, mínimo al comienzo .... Aproximadamente 1-1/2 pulg
Nivel de agua al término, máx .......................................................... Aproximadamente 1/4 pulg
Conexión de descarga .... Rosca de mangueras para jardín de 3/4 pulg con adaptador incluido,
Manguera para jardín de 1 pulg si se fija directamenta a la bomba
Diámetro de manguera de descarga ..................................................... D.I. mínimo de 3/4 pulg
Largo de manguera de descarga .......................................... Máximo recomendado de 15,24 m
Motor ................ Capacitor con división permanente, con protección contra sobrecarga térmica
Cable de alimentación ..................................................................... SJTW, 18 AWG/3C, 3,05 m
FABRICACIÓN
Carcasa del motor .......................................................................... Nailon retardador de llamas
Voluta (malla de entrada) ................................................................................. Nailon reforzado
Impulsor ............................................................................... Termoplástico reforzado con vidrio
11
Lowes.com
INFORMACIÓN DE SEGURIDAD
Lea y comprenda completamente este manual antes de intentar ensamblar, usar o instalar el
producto. Si tiene preguntas relacionadas con el producto, llame al Departamento de Servicio
al Cliente al 1-866-994-4148, de lunes a viernes de 8 a.m. a 8 p.m., hora estándar del Este.
ADVERTENCIA
La bomba se activará únicamente cuando el agua llegue a 3,81 cm aproximadamente y
se apagará automáticamente cuando quede aproximadamente 6,35 mm de agua.
Coloque la bomba en el lugar más bajo posible de modo que el agua fluya hacia la
bomba y la active.
No bombee líquidos inflamables o explosivos como petróleo, gasolina, queroseno, etanol, etc.
No use en presencia de vapores inflamables o explosivos. El uso de la bomba con líquidos
inflamables o cerca de ellos puede causar una explosión o incendio y provocar lesiones
personales graves o la muerte y daños a la propiedad.
Siempre desconecte la bomba de su fuente de alimentación antes de inspeccionarla.
No se pare en agua cuando la bomba esté conectada.
No toque la carcasa de la bomba mientras está en funcionamiento, ya que la bomba puede
estar CALIENTE y puede causar quemaduras graves en la piel.
No desensamble la carcasa del motor. Esta bomba NO tiene piezas internas reemplazables y
al desensamblarla puede causar una fuga de aceite o peligrosos problemas de cableado
eléctrico.
PRECAUCIÓN
La bomba sumergible para uso general está diseñada para transferir agua desde fosas,
fregaderos, cavidades de ventanas, cubiertas de piscinas, pisos inundados u otras áreas
inundadas. Esta bomba no ha sido probada ni aprobada para su uso en piscinas o zonas
marinas con agua salada.
Esta bomba está fabricada de materiales de alta resistencia y resistencia a la corrosión.
Brindará servicio sin problemas durante muchos años si se instala, mantiene y usa
adecuadamente. Sin embargo, una alimentación eléctrica inadecuada a la bomba o un
bloqueo de hielo, suciedad o desechos puede causar una falla en la bomba y posiblemente
cause daños adicionales por agua. Para minimizar el potencial de daños por agua debido a
una falla en la bomba, lea la sección de este manual sobre problemas y soluciones comunes
de la bomba, o llame 1-866-994-4148.
Esta bomba no está diseñada para funcionar como bomba de sumidero de instalación
permanente. Tampoco está diseñada para funcionar continuamente como una bomba para
fuentes o cascadas. Debido a que esta bomba tiene un motor lleno de aceite, NO se debe
usar en agua que contenga peces. Se debe usar la bomba con una manguera para jardín de
3/4 pulg de diámetro o más, o con el kit de manguera (articulo #313726).
Por seguridad, el motor de la bomba cuenta con un protector térmico con restablecimiento
automático que apaga automáticamente la bomba si se calienta demasiado.
El uso excesivo de esta function dañará la bomba y anulará la garantía.
Luego de que el protector térmico detecta que la bomba se ha enfriado a una temperatura
segura, permite que la bomba funcione normalmente. Si la bomba está enchufada, puede
reiniciarse inesperadamente.
12
Lowes.com
Precauciones de seguridad adicionales
1. Conozca las aplicaciones, las limitaciones y los posibles riesgos de la bomba.
2. Asegúrese de que la fuente de alimentación eléctrica sea adecuada para los requisitos de la
bomba.
3. SIEMPRE desconecte la alimentación de la bomba y drene toda el agua del sistema antes de
realizar mantenimiento.
4. Asegure la bomba en una base sólida y mantenga la bomba vertical y sobre lodo y arena
durante el funcionamiento a fin de maximizar la eficiencia de la bomba y evitar obstrucciones y
falla prematura de la bomba.
5. Fije la manguera de descarga antes de arrancar la bomba. La torsión de la bomba puede
causar que una manguera suelta se mueva con violencia y es posible que cause lesiones
personales o daños a la propiedad.
6. Antes de usar la bomba, verifique que la manguera no tenga orificios o desgaste excesivo que
pueda causar fugas, y asegúrese de que la manguera no esté torcida ni tenga ángulos
cerrados. Una manguera recta permite que la bomba mueva la mayor cantidad de agua
rápidamente.
7. Verifique que todas las conexiones estén apretadas para minimizar las fugas.
8. Conecte la bomba DIRECTAMENTE a un tomacorriente con interruptor de circuito de falla de
puesta a tierra (GFCI, por sus siglas en inglés).
9. Es posible que las extensiones eléctricas no proporcionen el voltaje suficiente al motor de la
bomba. Las extensions eléctricas presentan un riesgo para la seguridad y la vida si se daña el
aislamiento o si los extremos de la conexión caen al agua.
10. 10. Asegúrese de que el circuito eléctrico hacia la bomba esté protegido por un fusible de 10
amperios o más, o un interruptor de circuito.
11. Inspeccione periódicamente la bomba y los componentes del sistema para asegurarse de que
las entradas de la bomba estén libres de arena, lodo y desechos. DESCONECTE LA BOMBA
DEL SUMINISTRO DE ELECTRICIDAD ANTES DE INSPECCIONARLA.
12. Use gafas de seguridad en todo momento cuando trabaje con bombas.
13. Respete todos los códigos eléctricos y de seguridad, especialmente el Código nacional de
electricidad (NEC, por sus siglas en inglés) y en el lugar de trabajo, la Administración de Salud
y Seguridad Ocupacional (OSHA, por sus siglas en inglés).
14. Esta unidad está diseñada sólo para usarse en un servicio de 115 voltios (de fase única), 60
Hz, y está equipada con un cable conductor aprobado y un enchufe con puesta a tierra de 3
clavijas. NO RETIRE LA CLAVIJA DE PUESTA A TIERRA BAJO NINGUNA
CIRCUNSTANCIA. Se debe insertar directamente el enchufe de 3 clavijas en un tomacorriente
instalado adecuadamente, con la debida puesta a tierra y de 3 clavijas. No use la bomba con
un tomacorriente de pared de 2 clavijas. Reemplace el tomacorriente de 2 clavijas con un
tomacorriente de 3 clavijas con puesta a tierra (un tomacorriente GFCI) instalado en
conformidad con el Código nacional de electricidad y los códigos y las ordenanzas locales.
Todo el cableado debe realizarlo un electricista calificado.
15. Proteja el cable eléctrico de objetos afilados, superficies calientes, aceite y sustancias
químicas. Evite torcer el cable. No utilice cables dañados o desgastados.
13
Lowes.com
RENDIMIENTO
Modelo
HP
LPM de agua a un total de metros de cabeza
Elevación máxima
1.5 m
3 m
4.6 m
6.1 m
7.5 m
PPSU33
1/3
79
64
45
26
11
8,5 m
Para obtener un mejor rendimiento, el largo de manguera máximo recomendado es de 15,24 m.
La capacidad de bombeo o caudal de agua de cualquier bomba depende de varios factores. A
medida que el diámetro interior es mayor y el largo de manguera es más corto se pierde menos
presión, o el caudal es mayor. La presión máxima producida por esta bomba es 13 psi
aproximadamente. Si la manguera se instala de manera ascendente o es demasiado larga,
recomendamos usar una manguera de mayor diámetro o una tubería rígida.
PREPARACIóN
ADVERTENCIA: Siempre use la manija para levantar la bomba. Nunca use el cable de
alimentación para levantar la bomba. Para evitar quemaduras en la piel, desenchufe la
bomba y espere que se enfríe luego de su uso prolongado.
Antes de comenzar a ensamblar el producto, asegúrese de tener todas las piezas. Compare las
piezas con la lista del contenido del paquete. No intente ensamblar el producto si falta alguna
pieza o si estas están dañadas. Póngase en contacto con el Departamento de Servicio al Cliente
para obtener piezas de repuesto.
Tiempo estimado de ensamblaje (instalación nueva): 5 minutos
Materiales necesarios para el ensamblaje (no se incluyen): Manguera para jardín o kit de
manguera (Artículo #0313726)
La bomba debe estar apoyada sobre una base nivelada y sólida.
No suspenda la bomba de la manguera de descarga o el cable de alimentación.
Mantenga limpia la malla de entrada de la bomba.
No instale la bomba directamente sobre arena o tierra. Se requiere un nivel de agua
mínimo de 1-1/2 pulg para cebar la bomba.
INSTRUCCIONES DE INSTALACIÓN
1. Conecte el adaptador (B) incluido a las roscas de la bomba
(A).
Nota: El adaptador (B) cuenta con una válvula de control
integrada. El uso de este adaptador evitará el reflujo de agua
hacia la bomba (A).
B
A
14
Lowes.com
INSTRUCCIONES DE FUNCIONAMIENTO
AVISO: Asegúrese de desenrollar completamente la manguera para
jardín. Las torceduras en la manguera restringen la bomba y evitan
su cebado, el cual es el primer paso para bombear agua. El nivel de
agua debe ser 1-1/2 pulg aproximadamente para el cebado y
funcionamiento de la bomba.
1. Enchufe la bomba en un tomacorriente GFCI de 115 V.
ADVERTENCIA: No permita que el enchufe caiga al agua y no se
pare en el agua mientras la bomba (A) esté conectada.
Funcionamiento automático
La bomba (A) se activará únicamente si hay aproximadamente 3,81 cm de agua alrededor de
la bomba. El agua debe hacer contacto con las sondas del sensor de la bomba para que esta
última se active.
Cuando la bomba (A) retire agua hasta aproximadamente 6,35 mm de altura, esta seguirá
funcionando durante 30 segundos más y luego se apagará.
o Nota: Si la bomba (A) no se apaga, retírela y verifique para asegurarse de que no haya
agua u otros residuos que toquen las sondas del sensor.
La bomba puede permanecer enchufada y volverá a activarse automáticamente cuando
vuelva a haber aproximadamente 3,81 cm de agua.
2. Conecte una manguera para jardín de 3/4 pulg a las roscas
del adaptador (B) o sujete un kit de manguera de 1-1/4 pulg
(artículo # 0313726, se vende por separado) a los rebordes
del adaptador (B).
Nota: Asegúrese de que el extremo de la manguera para
jardín tenga una arandela de goma para minimizar fugas de
agua.
2
B
A
A
15
Lowes.com
BLOQUEO DE AIRE
Esta unidad es una bomba de uso general centrífuga, diseñada
para retirar agua eficientemente. Sin embargo, no puede mover
aire. Si hay aire atrapado dentro de la bomba (una condición
denominada “bloqueo de aire”), la bomba no puede bombear
agua fuera aunque la unidad esté completamente sumergida.
Esta bomba tiene el orificio contra bloqueo de aire (consulte la
Imagen 1 a continuación). El aire fluye hacia fuera a través del
orificio contra bloqueo de aire, eliminando el bloqueo de aire de
forma que la bomba pueda funcionar adecuadamente. Si el orificio
contra bloqueo de aire resulta bloqueado por desperdicios,
desenchufe la bomba, limpie el orificio contra bloqueo de aire y
reinicie la bomba. De forma alternada, drene el agua fuera de la
manguera para jardín, mantenga el extremo de la manguera
fuera del agua y enchufe el cable de alimentación, reiniciando
la bomba.
PRECAUCIÓN: Esta orificio es para fines contra bloqueo de aire. La fuga de aire o agua es
NORMAL. ¡NO RETIRE NI ENCHUFE ESTA ORIFICIA!
CUIDADO Y MANTENIMIENTO
Desenchufe periódicamente la bomba, asegurándose de
tener las manos secas y sin pararse en el agua. Al
desconectar la alimentación, inspeccione las entradas de la
bomba y retire todos los desechos, luego vuelva a enchufar
la bomba al tomacorriente con puesta a tierra (GFCI).
1. Para destapar una bomba obstruida con desechos,
primero, DESENCHUFE LA BOMBA de la
alimentación eléctrica. Luego consulte la Imagen 1 a
continuación, destornille los tornillos inoxidables (1),
retire la malla/la voluta (2), y la empaquetadura del
sello de (3) (NOTA: Lo más probable es que la
empaquetadura permanezca conectada a la bomba;
de ser así, solo retírela si necesita lavarla). Use una
llave (no se incluye) para retirar la tuerca (4) y luego haga palanca con cuidado para retirar
el impulsor (5). Volver a montar.
Limpieza de las sondas del sensor
En raras ocasiones es posible que las sondas de sensor se cubran de residuos, y esto puede
afectar el funcionamiento automático de la bomba. Si la bomba no se activa cuando haya
aproximadamente 3,81 cm de agua o si no se apaga después de retirar el agua, desenchúfela y
retírela del agua. Retire los dos tornillos de acero inoxidable (6) y retire el receptáculo de las
sondas del sensor (7). Habrá sondas de metal dentro del receptáculo. Limpie con cuidado las
sondas con un cepillo pequeño (no se incluye) y séquelas. Vuelve a ensamblar.
Orificio
contra
bloqueo
de aire
1
4
3
2
5
7
6
16
Lowes.com
Utilitech® es una marca registrada
de LF, LLC. Todos los derechos reservados.
SOLUCIÓN DE PROBLEMAS
Si tiene preguntas relacionadas con el producto, llame al Departamento de Servicio al Cliente al
1-866-994-4148, de lunes a viernes de 8 a.m. a 8 p.m., hora estándar del Este, de lunes a viernes.
AVISO: No desensamble la carcasa del motor. Esta motor NO tiene piezas internas reemplazables y
al desensamblarla puede causar una fuga de aceite o peligrosas condiciones de cableado eléctrico.
PROBLEMA
CAUSA POSIBLE
ACCIÓN CORRECTIVA
La bomba no
enciende ni
funciona.
1. Las sondas del sensor están
cubiertas de escombros
2. El fusible está fundido/El
interruptor de circuitos está
desconectado
3. El enchufe está desconectado
4. Hay una sobrecarga térmica
5. El enchufe está corroído
6. Hay una falla en el motor
1. Limpie las sondas del sensor (Consulte
la sección "Cuidado y Mantenimiento")
2. Cambie el fusible/Restablezca el
interruptor
3. Fije el enchufe
4. Desenchufe la bomba durante 30
minutos, luego enchúfela
5. Limpie las clavijas del enchufe
6. Llame al 1-866-994-4148
La bomba no
bombea
agua hacia
fuera.
1. La malla está obstruida
2. La manguera está torcida o
enroscada
3. Hay un bloqueo de aire
4. El diámetro de la manguera es
demasiado pequeño
5. La manguera es demasiado larga
6. El impulsor tiene el eje suelto
7. El impulsor está roto
1. Limpie la malla
2. Enderece la manguera
3. Limpie la característica de liberación de
bloqueo de aire
4. Use una manguera de mayor diámetro
5. Use una manguera más corta
6. Vuelva a ensamblar el impulsor
(Consulte la sección "Cuidado y
Mantenimiento")
7. Llame al 1-866-994-4148
GARANTíA
Este producto está garantizado contra defectos de fabricación por un período de 12 meses a partir de la
fecha de compra. Cualquier tipo de uso inadecuado, abuso o modificación anulan automáticamente esta
garantía. El distribuidor reparará o reemplazará la bomba si, a su completa discreción, determina que la
bomba falló debido a defectos en el material o en la mano de obra.
EXCLUSIONES DE LA GARANTÍA
1. Ni el distribuidor ni la tienda en que adquirió esta bomba serán responsables por los gastos de mano de
obra u otros similares en los que se incurran durante el retiro o la reparación de la bomba.
2. El distribuidor rechaza específi camente toda garantía implícita de comerciabilidad e idoneidad para un fi
n en particular.
3. Bajo ninguna circunstancia el distribuidor se responsabilizará de los daños resultantes, incidentals o
especiales que deriven de los componentes o accesorios del distribuidor.
4. El distribuidor renuncia a toda responsabilidad relacionada con la instalación inapropiada o uso
inadecuado de este producto.
Algunos estados no permiten la exclusión o limitación de daños accidentales o resultantes, por lo
que es posible que las exclusiones y las limitaciones anteriores no se apliquen en su caso. Además
de los derechos que le otorga esta garantía, podría tener también otros derechos que pueden variar
según el estado.
Para reclamos de garantía, NO DEVUELVA LA BOMBA A LA TIENDA.
Llame a nuestro Departamento de Servicio al Cliente al: 1-866-994-4148, de lunes a viernes de 8:00 a.m. a
5:00 p.m., hora estándar del Este. Impreso en China
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Utilitech PPSU33 Manual de usuario