CONEXION CON EL TABLERO DE BORNES
8
5
PEDESTRIAN
DOOR OPEN
INDICATOR
PHOTOCELL
PHOTO 2
STARTING
TORQUE
WORKING TIME
PAUSE TIME
FLASHING UNIT
OR COURTESY
LAMP
The pedestrian command enables opening of one gate leaf
on a 2-leaf model. If dip switch 1 is selected (sliding mode)
the gate opens for 1/3 of the working time.
The gate open indicator lamp notifies the user of the gate status.
Gate closed - lamp off.
Gate in opening phase - slow flashing lamp.
Gate open - lamp lit.
Gate in closing phase - fast flashing lamp.
The photocell command ensures that on interruption of the light
beam, all controls are inhibited.
During the opening phase, if the beam is interrupted, the gate
completes travel to the normal pause position. During the pause
phase, if the beam is interrupted, the gate remains in this status
until the beam is restored. When the beam is restored, the gate
remains in pause for a brief interval (1/4 of the set time) and then
closes. During the closing phase, if the beam is interrupted, the
gate changes to the opening phase.
The command in photo 2 is activated in the opening phase causing
gate shutdown. On reset gate opening is resumed. If shut down
during closing, opening is resumed.
Thrust is activated on opening and closing setting the maximum
force for 1 sec. to then return to the set power of the autotransformer.
Working time range from 2 sec. to 60 sec. (with dip switch 4
inserted regulation range is from 2 sec. to 120 sec.).
The adjustment trimmer to facilitate brief time settings on gate
movements has an exponential control range (finer at the start
of trimmer travel and is less so at the end).
Pause time range from 2 sec. to 180 sec. N.B.: During opening,
if the photocell beam is interrupted, the pause time if reduced to
1/4 of the set time.
The courtesy lamp uses the same relay as the flashing unit, and
extends operation time is selected for a fixed interval of 3 min.
GB
1-22 30VAC Alimentación de la red 230Vac 50 Mhz
3-4 LUZ PARPADEANTE Salida para luz parpadeante/luz interior (la selección
entre luz parpadeante e interior depende de la selección
del jumper predispuesto) en la tarjeta lógica de 230Vac máx.
para luz parpadeante, 100W máx. para luz interior.
5-6-7 MOTOR M1 Salida para motor 1 con retardo en apertura, el tiempo
se fija en un segundo 230Vac 400VA máx.
8-9-10 MOTOR M2 Salida para motor 2 con retardo en el cierre mediante el
trimmer TR de la SKL-2, 230Vac 400VA máx.
11-12 ELECTROCERRADURA Salida 12VCC que queda activada de 0,5 segundos antes a
4 segundos después del arranque de los motores en apertura
15W máx.
13-14 V Salida 24Vac para la alimentación de los servicios (fotos,
radio, etc.) máximo 400mA.
15-16 FIN DE CARRERA ABRE Ingreso para fin de carrera de apertura.
15-17 FIN DE CARRERA CIERRA Ingreso para fin de carrera de cierre.
15-18 FOTOCELULA 2 Ingreso para dispositivos de seguridad también en
apertura (fotocélulas, perfiles de seguridad).
15-19 STOP Ingreso para mando de stop (emergencia, bloqueo o
seguridad exterior)
15-20 FOTOCELULA 1 Ingreso para dispositivos de seguridad (fotocélulas,
perfiles de seguridad).
21-25 CIERRA Ingreso para mando de cierre.
22-25 ABRE Ingreso para mando de apertura.
23-25 PASO/PASO Ingreso para funcionamiento cíclico (abre-stop-cierra-stop).
24-25 PEATONAL Ingreso para mando peatonal.
25-15 CONTACTO COMUN Contacto común para los ingresos
26-27 LUZ TESTIGO R.A. Salida para la luz testigo reja abierta 24Vac máx. 2W.
28-29 SALIDA 2 CANAL Salida 2° CANAL SK radio.
30-31 ANTENA Ingreso para la antena del receptor radio