Watts RBFF Guía de instalación

Categoría
Artículos sanitarios
Tipo
Guía de instalación

Este manual también es adecuado para

ENGLISH INSTRUCTIONS
RBFF
IS-RBFF
IS-RBFF 0939 EDP# 1915405 © Watts, 2009
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects
in material and workmanship under normal usage for a period of one year from the date of original ship-
ment. In the event of such defects within the warranty period, the Company will, at its option, replace
or recondition the product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY
GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER
WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive
remedy for breach of warranty, and the Company shall not be responsible for any incidental, special
or consequential damages, including without limitation, lost profits or the cost of repairing or replacing
other property which is damaged if this product does not work properly, other costs resulting from labor
charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water
conditions, chemical, or any other circumstances over which the Company has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance
or alteration of the product.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow
the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may
not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights
that vary from State to State. You should consult applicable state laws to determine your rights. SO
FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT
BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL
SHIPMENT.
IS-RBFF 0939 EDP# 1915405 © Watts, 2009
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
Garantía limitada: Watts Regulator Co. (en adelante, “la Compañía”) garantiza, por un período de un año a
partir de la fecha de embarque original, que sus productos están libres de defectos en materiales y mano de obra
bajo condiciones de uso normal. En caso de que se encuentren tales defectos dentro del período de garantía, la
Compía reemplazará o reacondicionará, a su elección, el producto sin costo alguno.
LA GARANTÍA AQ ESTIPULADA SE OTORGA EN FORMA EXPRESA Y ES LA ÚNICA GARANA
OTORGADA POR LA COMPAÑÍA EN RELACIÓN CON EL PRODUCTO. LA COMPAÑÍA NO OTORGA NINGUNA
OTRA GARANA, YA SEA EXPRESA O IMPCITA. LA COMPÍA POR LA PRESENTE RENUNCIA
ESPECÍFICAMENTE A TODAS LAS DEMÁS GARANTÍAS, EXPRESAS O IMPLÍCITAS, INCLUYENDO SIN
LIMITACIÓN, LAS GARANTÍAS IMPLÍCITAS DE APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA
UN PROPÓSITO EN PARTICULAR.
La solución descrita en el primer párrafo de esta garantía constituirá la única y exclusiva solución por incum-
plimiento de garantía, y la Compañía no se hará responsable por dos accidentales, especiales o indirectos,
incluyendo sin limitación, la pérdida de ganancias o el costo de reparación o reemplazo de otra propiedad que
resulte dada por el mal funcionamiento de este producto, otros costos resultantes por mano de obra, retardos,
vandalismo, negligencia, obstrucciones ocasionadas por materiales extraños, daños debidos a condiciones
adversas del agua, químicos o cualquier otra circunstancia sobre la cual la Compañía no tenga control. Esta
garantía no tendrá validez en cualquier caso de abuso, uso indebido, aplicación incorrecta, instalación inadec-
uada, o mantenimiento adecuado o alteración del producto.
Algunos Estados no permiten limitaciones en la duración de una garantía implícita y algunos Estados no permiten
la exclusión o limitación de daños accidentales o indirectos. Por lo tanto, es posible que las limitaciones anteriores
no sean aplicables en su caso. Esta garantía limitada le da derechos legales específicos; usted podría tener tam-
bién otros derechos que varían según el Estado. Usted debe consultar las leyes estatales aplicables para deter-
minar sus derechos. EN LA MEDIDA EN QUE SEA CONGRUENTE CON LAS LEYES ESTATALES APLICABLES,
CUALQUIER GARANTÍA IMPLÍCITA QUE NO SEA RECHAZADA, INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE
APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA UN PROPÓSITO EN PARTICULAR, SE LIMITA EN
SU DURACIÓN A UN AÑO A PARTIR DE LA FECHA DEL EMBARQUE ORIGINAL.
USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
Garantie limitée: Watts Regulator Co. (la « Société ») garantit que chacun de ses produits est exempt de
vice de matériau et de fabrication dans des conditions normales d’utilisation pour une période d’un an à
compter de la date d’expédition d’origine. Dans l’éventualité où de tels vices se manifesteraient pendant
la période de garantie, la Société, à sa discrétion, remplacera ou reconditionnera le produit sans frais.
LA PRÉSENTE GARANTIE EST EXPRESSE ET REPRÉSENTE LA SEULE GARANTIE OFFERTE PAR
LA SOCIÉTÉ POUR CE PRODUIT. LA SOCIÉTÉ N’OFFRE AUCUNE AUTRE GARANTIE, EXPRESSE OU
TACITE. PAR LA PRÉSENTE, LA SOCIÉTÉ REJETTE SPÉCIFIQUEMENT TOUTE AUTRE GARANTIE,
EXPRESSE OU TACITE, NOTAMMENT TOUTE GARANTIE TACITE DE QUALITÉ MARCHANDE OU
D’ADAPTATION À UN BUT PARTICULIER.
Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation
de la présente garantie. La Société ne saurait être tenue responsable de tout dommage accessoire, spé-
cial ou indirect, y compris, de façon non limitative : la perte de profits ou le coût afférent à la réparation ou
au remplacement d’autres biens qui seraient endommagés par suite du fonctionnement incorrect dudit
produit ; d’autres coûts résultant de frais de main-d’œuvre, de retards, de vandalisme, de négligence,
d’une obstruction causée par des matériaux étrangers, de dommages causés par une eau impropre,
des produits chimiques ou par tout autre événement échappant au contrôle de la Société. La présente
garantie est déclarée nulle et non avenue en cas d’usage abusif ou incorrect, d’application, d’installation
ou d’entretien incorrects ou de modification du produit.
Certains États n’autorisent pas les limitations de durée d’une garantie tacite ou l’exclusion ou la limita-
tion des dommages accessoires ou indirects. Les limitations susmentionnées peuvent donc ne pas
s’appliquer à vous. Cette garantie limitée vous donne des droits spécifiques et il se peut que vous ayez
aussi d’autres droits qui varient d’un État à l’autre. Veuillez vous référer aux lois applicables de l’État pour
déterminer vos droits en la matière. DANS LA MESURE PERMISE PAR LA LOI APPLICABLE DE L’ÉTAT,
TOUTES LES GARANTIES TACITES NE POUVANT PAS ÊTRE REJETÉES, Y COMPRIS LES GARANTIES
TACITES DE QUALITÉ MARCHANDE ET D’ADAPTATION À UN BUT PARTICULIER, SONT LIMITÉES
QUANT À LEUR DURÉE À UN AN À COMPTER DE LA DATE D’EXPÉDITION D’ORIGINE.
Model RBFF Residential Boiler Fill Fitting should be installed in closed-loop hot
water heating systems as per the piping diagram shown in the Figure 1. Refer to
Figure 2 for RBFF port identification.
Installation Instructions
1. Pipe the system port of the RBFF into the bottom tapping of the air separator
using a 1/2" black or brass nipple. The RBFF can be installed with the valve
handle and pressure gauge facing in any direction - select a 1/2" nipple length
appropriate for the installation and tighten until positioned for easy access
and/or piping considerations. Be sure to allow enough room for operation of
the water pressure regulator valve fast-fill lever.
2. Install the expansion tank in the bottom 1/2" female expansion tank port of
the RBFF.
3. The water pressure regulator valve may be installed directly to the 1/2" male
thread of the RBFF fill port. The use of a backflow prevention device such as
the Watts 9D is recommended – check local codes for backflow prevention
requirements.
Important Note: A shutoff valve must be installed on the cold water line
upstream of the water pressure regulator valve and backflow device!
Normal Operation
During normal operation of the heating system, the
RBFF valve handle must be locked in the all-ports-
open position as shown in Figure 3 with drain
port closed (screwdriver slot perpendicular to the
drain port) and drain port cap installed. To operate
valve, push in to disengage spring-loaded handle
from locking tab. The handle can be turned in
either direction and will pop up and lock in place
at the four positions shown in Figures 3 through 6.
The short nub indicates the closed port; the long
wings indicate the open ports.
Function 1 - Expansion Tank
Replacement/Air
Charge Maintenance
1. Push in and turn RBFF handle 90° counter-
clockwise and lock into the expansion tank-
port-closed position as shown in Figure 4.
2. Make certain RBFF drain port is closed – the
screwdriver slot must be perpendicular to the
drain port. Slowly remove cover from drain port
and attach hose.
3. Slowly open drain port by turning the drain port
valve to the open position (screwdriver slot par-
allel to drain port) to relieve pressure on expan-
sion tank diaphragm.
4. Using a suitable air pressure gauge, check
expansion tank air charge level via the tank’s
Schrader valve and adjust as needed.
Important note - see expansion tank manu-
facturer’s instructions for additional information
on charging expansion tank! The air pressure
charge should match the system fill pressure
(water pressure regulator valve) setting. If replac-
ing tank, remove old tank and install new tank.
Check air charge in new tank and adjust if needed.
Model RBFF
Modelo RBFF
Modèle RBFF
Residential Boiler Fill Fitting
Empalme para el llenado de calderas residenciales
Accessoire de remplissage
pour chaudière domestique
Size:
1
2" (15mm)
Tamaño:
1
2 pulg. (15 mm)
Diamètre :
1
2 po (15 mm)
Installation Instructions
Instrucciones de instalación
Instructions d’installation
RBFF
IS-RBFF 0939 EDP# 1915405 © Watts, 2009
Fig. 1
Fig. 2
System
Port
Fill Port
Drain Port
Valve
Drain Port
Cover
Expansion Tank
Port
5. Close drain port (screwdriver slot perpendicular
to drain port).
6. Remove hose from drain port and reinstall drain
port cover.
7. Push in and turn RBFF handle 90° clockwise
and lock into all-ports-open position as shown in
Figure 3 to place system back in operation.
Function 2 - Water Pressure
Regulator Valve
Service/Replacement
1. Push in and turn RBFF handle 180° and lock into
the fill-port-closed position as shown in Figure 5.
2. Close isolation valve on the cold water supply line
to water pressure regulator valve.
3. Service/replace water pressure regulator valve.
4. Slowly open supply line valve to water pressure regulator valve.
5. Push in and turn RBFF handle 180° and lock into the all-ports-open position as
shown in Figure 3 to place system back in operation.
Function 3 - Water Pressure Regulator Valve Adjustment
To increase system fill pressure:
1. Follow the entire Function 1 procedure above to set expansion tank air charge to
match desired fill pressure level.
2. Push in and turn RBFF handle and lock into the system-port-closed position as
shown in Figure 6.
3. Using the RBFF pressure gauge as a reference, adjust water pressure regulator valve
to desired level.
4. Push in and turn RBFF handle 90
° counterclockwise and lock into the all-ports-open
position as shown in Figure 3 to place system back in operation.
Fig. 3
Fig. 4
Fig. 5
To decrease system fill pressure:
1. Push in and turn RBFF handle 90° clock-
wise and lock into the system-port-closed
position as shown in Figure 6.
2. Turn water pressure regulator valve adjust-
ment screw to reduce pressure.
3. Make certain RBFF drain port is closed
the screwdriver slot must be perpendicular
to the drain port. Slowly remove cover
from drain port and attach hose.
4. Slowly open drain port (screwdriver slot
parallel to drain port) until water pressure
regulator valve starts to fill.
5. Close drain port (screwdriver slot perpendicular to drain port) and read pres-
sure on the RBFF pressure gauge.
6. Repeat steps 2 through 5 as necessary to achieve desired fill pressure.
7. Remove hose from drain port and reinstall drain port cover.
8. Follow all steps in the Function 1 section above to reset expansion tank air
charge to match the water pressure regulator valve setting.
Other Functions
The ball valve drain port may also be used for a variety of other draining and fill-
ing operations. The RBFF handle will usually be rotated 180° and locked into the
fill-port-closed position for these operations.
Fig. 6
INSTRUCCIONES EN ESPAÑOL
INSTRUCTIONS EN FRANçAIS
El empalme para el llenado de calderas residenciales modelo RBFF debe instalarse en
los sistemas de calefacción con agua caliente en ciclo cerrado según el diagrama de
tuberías que se muestra en la Figura 1. Consulte la Figura 2 para la identificación de los
puertos del RBFF.
Instrucciones de instalación
1. Conecte el puerto del sistema del RBFF en la conexión intermedia inferior del
separador de aire con conector negro o de latón de 1/2 pulg. El RBFF puede
instalarse con el monomando de la válvula y el medidor de presión hacia cualquier
dirección. Seleccione un conector de 1/2 pulg. de una longitud adecuada para
la instalación y ajuste hasta que quede en posición para un fácil acceso y/o
consideraciones de la tubería. Asegúrese de permitir espacio suficiente para la
operación de la palanca de llenado rápido de la válvula reguladora de presión del
agua.
2. Instale el tanque de expansión en el puerto de tanque de expansión hembra inferior
de 1/2 pulg. del RBFF.
3. Es posible instalar la válvula reguladora de la presión de agua directamente en la
rosca macho de 1/2 pulg. del puerto de llenado del RBFF. Se recomienda usar un
dispositivo de prevención de reflujo como el Watts 9D. Consulte los códigos locales
para ver los requisitos de prevención de reflujo.
Nota importante: ¡Debe instalarse una válvula de cierre en el conducto de agua fría
contra la corriente de la válvula reguladora de la presión de agua y del dispositivo de
reflujo!
Funcionamiento normal
Durante el funcionamiento normal del sistema de
calefacción, el monomando de la válvula del RBFF
debe estar trabado en la posición de todos los puertos
abiertos, tal como se muestra en la Figura 3, con el
puerto de drenaje cerrado (ranura de destornillador
perpendicular al puerto de drenaje) y la tapa del puerto
de drenaje debe estar instalada. Para operar la válvula,
presione para destrabar el monomando accionado
por resorte de la pestaña con traba. El monomando
puede girarse en ambas direcciones y saldrá y se
trabará en las cuatro posiciones que se muestran en
las figuras 3 a 6. La protuberancia corta indica que
el puerto está cerrado; las alas largas indican que los
puertos están abiertos.
Función 1 – Reemplazo del tanque de expansión/
mantenimiento de la carga de aire
1. Presione y gire el monomando del RBFF 90° en
sentido antihorario y trábelo en la posición de puerto
de tanque de expansión cerrado, tal como se
muestra en la Figura 4.
2. Asegúrese de que el puerto de drenaje del RBFF
esté cerrado. La ranura de destornillador debe estar
perpendicular al puerto de drenaje. Quite lentamente
la tapa del puerto de drenaje y conecte la manguera.
3. Abra lentamente el puerto de drenaje girando la
válvula del puerto de drenaje a la posición abierta
(ranura de destornillador paralela al puerto de
drenaje) para dejar salir la presión del diafragma del
tanque de expansión.
4. Con un medidor de presión de aire adecuado,
verifique el nivel de carga de aire del tanque de
expansión mediante la válvula Schrader del tanque y
ajuste según sea necesario.
Nota importante: ¡Consulte las instrucciones del
fabricante del tanque de expansión para ver información adicional sobre cómo cargar
el tanque de expansión! La carga de presión de aire debe coincidir con el parámetro
de la presión de llenado del sistema (válvula reguladora de la presión de agua). Si está
reemplazando el tanque, quite el tanque antiguo e instale el nuevo tanque. Verifique
Fig. 1
Fig. 2
Puerto del
sistema
Puerto de
llenadot
Válvula del
puerto de
drenaje
Tapa del
puerto de
drenaje
Puerto del
tanque de
expansión
la carga de aire del nuevo tanque y ajústela de ser
necesario.
5. Cierre el puerto de drenaje (ranura de destornillador
perpendicular al puerto de drenaje).
6. Quite la manguera del puerto de drenaje y reinstale la
tapa del puerto de drenaje.
7. Presione y gire el monomando del RBFF 90° en
sentido horario y trábelo en la posición de todos los
puertos abiertos, tal como se muestra en la Figura 3,
para que el sistema esté nuevamente en operación.
Función 2 – Mantenimiento/
reemplazo de la válvula
reguladora de la
presión de agua
1. Presione y gire el monomando del RBFF 180° y trábelo en la posición de puerto de llenado
cerrado tal como se muestra en la Figura 5.
2. Cierre la válvula de aislamiento del conducto de agua fría a la válvula reguladora de la presión
de agua.
3. Realice el mantenimiento/reemplace la válvula reguladora de la presión de agua.
4. Abra lentamente la válvula del conducto a la válvula reguladora de la presión de agua.
5. Presione y gire el monomando del RBFF 180° en sentido horario y trábelo en la posición
de todos los puertos abiertos, tal como se muestra en la Figura 3, para que el sistema esté
nuevamente en operación.
Función 3 – Ajuste de la válvula reguladora de la
presión de agua
Para aumentar la presión de llenado del sistema:
1. Siga todo el procedimiento de la Función 1 anterior para configurar la carga de aire del
tanque de expansión para que coincida con el nivel de presión de llenado deseado.
2. Presione y gire el monomando del RBFF y trábelo en la posición de puerto del sistema
cerrado tal como se muestra en la Figura 6.
Fig. 3
Fig. 4
Fig. 5
3. Con el medidor de presión del RBFF como
referencia, ajuste la válvula reguladora de la
presión de agua en el nivel deseado.
4. Presione y gire el monomando del RBFF 90°
en sentido antihorario y trábelo en la posición
de todos los puertos abiertos, tal como se
muestra en la Figura 3, para que el sistema
esté nuevamente en operación.
Para disminuir la presión de llenado del sistema:
1. Presione y gire el monomando del RBFF 90°
en sentido horario y trábelo en la posición
de puerto del sistema cerrado, tal como se
muestra en la Figura 6.
2. Gire el tornillo de ajuste de la válvula reguladora de la presión de agua para reducir
la presión.
3. Asegúrese de que el puerto de drenaje del RBFF esté cerrado. La ranura de
destornillador debe estar perpendicular al puerto de drenaje. Quite lentamente la
tapa del puerto de drenaje y conecte la manguera.
4. Abra lentamente el puerto de drenaje (ranura de destornillador paralela al puerto de
drenaje) hasta que comience a llenarse la válvula reguladora de la presión de agua.
5. Cierre el puerto de drenaje (ranura de destornillador perpendicular al puerto de
drenaje) y lea la presión del medidor de presión del RBFF.
6. Repita los pasos 2 a 5 según sea necesario para lograr la presión de llenado
deseada.
7. Quite la manguera del puerto de drenaje y reinstale la tapa del puerto de drenaje.
8. Siga todos los pasos de la sección correspondiente a la Función 1 anterior para
restablecer la carga de aire del tanque de expansión con el fin de que coincida con
la configuración de la válvula reguladora de la presión de agua.
Otras funciones
El puerto de drenaje de la válvula esférica también puede usarse para otras
operaciones de drenaje y llenado. El monomando del RBFF generalmente estará con
una rotación de 180° y trabado en la posición de puerto de llenado cerrado para estas
operaciones.
Fig. 6
L'accessoire RBFF de remplissage pour chaudière domestique doit être monté sur des
systèmes de traitement de l'eau chaude en circuit fermé, en accord avec le schéma de
tuyauterie (Fig. 1). Se référer à la Figure 2 au sujet des orifices.
Instructions d’installation
1. Avec un tuyau, raccorder l'orifice-système de l'accessoire RBFF au taraudage
inférieur du séparateur d'air (utiliser un mamelon en laiton ou noir de
1/2 po). Le RBFF peut être monté avec le robinet et le manomètre tournés dans
n'importe quelle direction – choisir un mamelon de 1/2 po de diamètre et de
longueur adéquate selon le montage, puis orienter en serrant, en vue de faciliter
l'accès ou la pose de la tuyauterie. Veiller à laisser suffisamment d'espace pour le
levier de remplissage rapide du régulateur de pression d'eau.
2. Fixer le réservoir de dilatation à l'orifice-réservoir de dilatation de 1/2 po
(partie inférieure du RBFF).
3. Le régulateur de pression d'eau peut être fixé directement au filetage extérieur de
1/2 po de l'orifice-remplissage du RBFF. Il est conseillé d'utiliser un dispositif de
non-retour, tel le 9D de Watts – prendre connaissance des exigences des codes
locaux à ce sujet.
Avis important : Un robinet d'arrêt doit être posé sur la conduite d'eau froide, en
amont du régulateur de pression d'eau et du dispositif de non retour !
Service normal
En service normal du système de chauffage, le
robinet du RBFF doit être verrouillé en position « tous
les orifices ouverts » (cf. Figure 3), exception faite
de l'orifice de vidange qui doit être fermé (fente de
tournevis perpendiculaire à cet orifice) et bouché par la
mise en place de son couvercle. Pour régler le robinet,
l'enfoncer d'abord pour le libérer de la patte de
verrouillage ; le tourner ensuite dans un sens ou dans
l'autre, puis le relâcher : il remontera et se verrouillera
dans l'une des quatre positions (Figures 3 à 6). (La
pièce courte indique l'orifice fermé ; les longues ailettes
indiquent les orifices ouverts).
Fonction 1 - Remplacement
du réservoir de
dilatation/Entretien de la charge d'air
1. Enfoncer le robinet du RBFF et le tourner à 90°
dans le sens anti-horaire ; relâcher et verrouiller en
position « orifice-réservoir de dilatation fermé »
(cf. Figure 4).
2. S'assurer que l'orifice de vidange du RBFF est bien
fermé : la fente de tournevis doit être perpendiculaire
à cet orifice. Enlever délicatement le couvercle de
l'orifice, puis y raccorder un tuyau flexible.
3. Ouvrir l'orifice de vidange, en tournant lentement
son robinet en position ouverte (fente de tournevis
parallèle à l'orifice de vidange), afin de diminuer la
pression sur la membrane du réservoir de dilatation.
4. À l'aide d'un contrôleur adéquat de pression d'air,
vérifier le niveau de charge d'air du réservoir par la
vanne Schrader de celui-ci. Régler au besoin.
Avis important - Consulter les instructions du
fabricant du réservoir de dilatation pour obtenir des
informations complémentaires sur le chargement
du réservoir ! La charge d'air doit correspondre
au réglage de remplissage-pressurisation du
système (régulateur de pression d'eau). En cas de
Fig. 1
Fig. 2
Orifice-
système
Orifice-
remplissage
Robinet de
vidange
Couvercle de
l'orifice de
vidange
Orifice-réservoir
de dilatation
remplacement, retirer le réservoir usé et poser un
réservoir neuf. Vérifier la charge d'air dans le nouveau
réservoir et régler au besoin.
5. Fermer l'orifice de vidange (fente de tournevis
perpendiculaire à cet orifice).
6. Retirer le tuyau flexible de l'orifice, puis remettre son
couvercle.
7. Enfoncer le robinet du RBFF et le tourner à 90° dans
le sens horaire ; relâcher et verrouiller en position
« tous les orifices ouverts » (cf. Figure 3) pour
remettre le système en service.
Fonction 2 - Réparation/
remplacement du
régulateur de pression
d'eau
1. Enfoncer le robinet du RBFF et le tourner à 180° ; relâcher et verrouiller en position « orifice-
remplissage fermé » (cf. Figure 5).
2. Fermer le robinet d'isolement sur la conduite d'arrivée d'eau froide vers le régulateur de
pression d'eau.
3. Réparer/remplacer le régulateur.
4. Ouvrir lentement le robinet d'arrivée d'eau vers le régulateur.
5. Enfoncer le robinet du RBFF et le tourner à 180° ; relâcher et verrouiller en position « tous les
orifices ouverts » (cf. Figure 3) pour remettre le système en service.
Fonction 3 - Réglage du régulateur de pression d'eau
Pour augmenter la pression de remplissage du système :
1. Suivre toute la procédure Fonction 1 ci-dessus, afin de régler la charge d'air du réservoir de
dilatation en accord avec le niveau de pression de remplissage souhaité.
2. Enfoncer le robinet du RBFF et le tourner en position « orifice-système fermé » (cf. Figure 6).
Relâcher pour verrouiller.
3. En se référant au manomètre du RBFF, régler le régulateur de pression d'eau au niveau
souhaité.
Fig. 3
Fig. 4
Fig. 5
4. Enfoncer le robinet du RBFF et le tourner
à 90° dans le sens anti-horaire ; relâcher
et verrouiller en position « tous les orifices
ouverts » (cf. Figure 3) pour remettre le
système en service.
Pour diminuer la pression de remplissage du
système :
1. Enfoncer le robinet du RBFF et le tourner à
90° dans le sens horaire en position « orifice-
système fermé » (cf. Figure 6). Relâcher pour
verrouiller.
2. Tourner la vis de réglage du régulateur pour
diminuer la pression.
3. S'assurer que l'orifice de vidange du RBFF
est bien fermé : la fente de tournevis doit être
perpendiculaire à cet orifice. Enlever délicatement le couvercle de l'orifice, puis y
raccorder un tuyau flexible.
4. Ouvrir lentement l'orifice de vidange (fente de tournevis parallèle à cet orifice),
jusqu'à ce que le régulateur commence à se remplir.
5. Fermer l'orifice de vidange (fente de tournevis perpendiculaire à cet orifice), puis
constater la pression indiquée par le manomètre du RBFF.
6. Répéter au besoin les étapes 2 à 5 pour établir la pression souhaitée.
7. Retirer le tuyau flexible de l'orifice, puis remettre son couvercle.
8. Suivre toutes les étapes de la Fonction 1 ci-dessus pour rétablir la charge d'air du
réservoir de dilatation au réglage correspondant du régulateur de pression d'eau.
Autres fonctions
L'orifice de vidange avec robinet à tournant sphérique est utile dans plusieurs activités
de vidange et de remplissage. Normalement, le robinet du RBFF sera alors tourné à
180° et verrouillé en position « orifice-remplissage fermé » pour permettre ces activités.
Fig. 6

Transcripción de documentos

4. P  ush in and turn RBFF handle 90° counterclockwise and lock into the all-ports-open position as shown in Figure 3 to place system back in operation. The ball valve drain port may also be used for a variety of other draining and filling operations. The RBFF handle will usually be rotated 180° and locked into the fill-port-closed position for these operations. Other Functions 8. F  ollow all steps in the Function 1 section above to reset expansion tank air charge to match the water pressure regulator valve setting. 7. Remove hose from drain port and reinstall drain port cover. 6. Repeat steps 2 through 5 as necessary to achieve desired fill pressure. 5. C  lose drain port (screwdriver slot perpendicular to drain port) and read pressure on the RBFF pressure gauge. 4. S  lowly open drain port (screwdriver slot parallel to drain port) until water pressure regulator valve starts to fill. Fig. 6 Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product. Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. Garantía limitada: Watts Regulator Co. (en adelante, “la Compañía”) garantiza, por un período de un año a partir de la fecha de embarque original, que sus productos están libres de defectos en materiales y mano de obra bajo condiciones de uso normal. En caso de que se encuentren tales defectos dentro del período de garantía, la Compañía reemplazará o reacondicionará, a su elección, el producto sin costo alguno. LA GARANTÍA AQUÍ ESTIPULADA SE OTORGA EN FORMA EXPRESA Y ES LA ÚNICA GARANTÍA OTORGADA POR LA COMPAÑÍA EN RELACIÓN CON EL PRODUCTO. LA COMPAÑÍA NO OTORGA NINGUNA OTRA GARANTÍA, YA SEA EXPRESA O IMPLÍCITA. LA COMPAÑÍA POR LA PRESENTE RENUNCIA ESPECÍFICAMENTE A TODAS LAS DEMÁS GARANTÍAS, EXPRESAS O IMPLÍCITAS, INCLUYENDO SIN LIMITACIÓN, LAS GARANTÍAS IMPLÍCITAS DE APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA UN PROPÓSITO EN PARTICULAR. La solución descrita en el primer párrafo de esta garantía constituirá la única y exclusiva solución por incumplimiento de garantía, y la Compañía no se hará responsable por daños accidentales, especiales o indirectos, incluyendo sin limitación, la pérdida de ganancias o el costo de reparación o reemplazo de otra propiedad que resulte dañada por el mal funcionamiento de este producto, otros costos resultantes por mano de obra, retardos, vandalismo, negligencia, obstrucciones ocasionadas por materiales extraños, daños debidos a condiciones adversas del agua, químicos o cualquier otra circunstancia sobre la cual la Compañía no tenga control. Esta garantía no tendrá validez en cualquier caso de abuso, uso indebido, aplicación incorrecta, instalación inadecuada, o mantenimiento adecuado o alteración del producto. Algunos Estados no permiten limitaciones en la duración de una garantía implícita y algunos Estados no permiten la exclusión o limitación de daños accidentales o indirectos. Por lo tanto, es posible que las limitaciones anteriores no sean aplicables en su caso. Esta garantía limitada le da derechos legales específicos; usted podría tener también otros derechos que varían según el Estado. Usted debe consultar las leyes estatales aplicables para determinar sus derechos. EN LA MEDIDA EN QUE SEA CONGRUENTE CON LAS LEYES ESTATALES APLICABLES, CUALQUIER GARANTÍA IMPLÍCITA QUE NO SEA RECHAZADA, INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE APTITUD PARA LA COMERCIALIZACIÓN E IDONEIDAD PARA UN PROPÓSITO EN PARTICULAR, SE LIMITA EN SU DURACIÓN A UN AÑO A PARTIR DE LA FECHA DEL EMBARQUE ORIGINAL. 3. M  ake certain RBFF drain port is closed – the screwdriver slot must be perpendicular to the drain port. Slowly remove cover from drain port and attach hose. 2. T  urn water pressure regulator valve adjustment screw to reduce pressure. 7. P  ush in and turn RBFF handle 90° clockwise and lock into all-ports-open position as shown in Figure 3 to place system back in operation. 1. P  ush in and turn RBFF handle 90° clockwise and lock into the system-port-closed position as shown in Figure 6. To decrease system fill pressure: Garantie limitée: Watts Regulator Co. (la « Société ») garantit que chacun de ses produits est exempt de vice de matériau et de fabrication dans des conditions normales d’utilisation pour une période d’un an à compter de la date d’expédition d’origine. Dans l’éventualité où de tels vices se manifesteraient pendant la période de garantie, la Société, à sa discrétion, remplacera ou reconditionnera le produit sans frais. LA PRÉSENTE GARANTIE EST EXPRESSE ET REPRÉSENTE LA SEULE GARANTIE OFFERTE PAR LA SOCIÉTÉ POUR CE PRODUIT. LA SOCIÉTÉ N’OFFRE AUCUNE AUTRE GARANTIE, EXPRESSE OU TACITE. PAR LA PRÉSENTE, LA SOCIÉTÉ REJETTE SPÉCIFIQUEMENT TOUTE AUTRE GARANTIE, EXPRESSE OU TACITE, NOTAMMENT TOUTE GARANTIE TACITE DE QUALITÉ MARCHANDE OU D’ADAPTATION À UN BUT PARTICULIER. Le recours décrit dans le premier paragraphe de cette garantie constitue le seul recours à toute violation de la présente garantie. La Société ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, de façon non limitative : la perte de profits ou le coût afférent à la réparation ou au remplacement d’autres biens qui seraient endommagés par suite du fonctionnement incorrect dudit produit ; d’autres coûts résultant de frais de main-d’œuvre, de retards, de vandalisme, de négligence, d’une obstruction causée par des matériaux étrangers, de dommages causés par une eau impropre, des produits chimiques ou par tout autre événement échappant au contrôle de la Société. La présente garantie est déclarée nulle et non avenue en cas d’usage abusif ou incorrect, d’application, d’installation ou d’entretien incorrects ou de modification du produit. Certains États n’autorisent pas les limitations de durée d’une garantie tacite ou l’exclusion ou la limitation des dommages accessoires ou indirects. Les limitations susmentionnées peuvent donc ne pas s’appliquer à vous. Cette garantie limitée vous donne des droits spécifiques et il se peut que vous ayez aussi d’autres droits qui varient d’un État à l’autre. Veuillez vous référer aux lois applicables de l’État pour déterminer vos droits en la matière. DANS LA MESURE PERMISE PAR LA LOI APPLICABLE DE L’ÉTAT, TOUTES LES GARANTIES TACITES NE POUVANT PAS ÊTRE REJETÉES, Y COMPRIS LES GARANTIES TACITES DE QUALITÉ MARCHANDE ET D’ADAPTATION À UN BUT PARTICULIER, SONT LIMITÉES QUANT À LEUR DURÉE À UN AN À COMPTER DE LA DATE D’EXPÉDITION D’ORIGINE. USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca IS-RBFF 0939 EDP# 1915405 © Watts, 2009 USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca IS-RBFF 0939 EDP# 1915405 ENGLISH INSTRUCTIONS Fig. 5 6. R  emove hose from drain port and reinstall drain port cover. © Watts, 2009 1. P  ush in and turn RBFF handle 180° and lock into the fill-port-closed position as shown in Figure 5. During normal operation of the heating system, the RBFF valve handle must be locked in the all-portsopen position as shown in Figure 3 with drain port closed (screwdriver slot perpendicular to the drain port) and drain port cap installed. To operate valve, push in to disengage spring-loaded handle from locking tab. The handle can be turned in either direction and will pop up and lock in place at the four positions shown in Figures 3 through 6. The short nub indicates the closed port; the long wings indicate the open ports. EDP# 1915405 RBFF Fig. 4 3. U  sing the RBFF pressure gauge as a reference, adjust water pressure regulator valve to desired level. 2. P  ush in and turn RBFF handle and lock into the system-port-closed position as shown in Figure 6. To increase system fill pressure: Function 3 - Water Pressure Regulator Valve Adjustment 5. P  ush in and turn RBFF handle 180° and lock into the all-ports-open position as shown in Figure 3 to place system back in operation. 3. Service/replace water pressure regulator valve. 2. C  lose isolation valve on the cold water supply line to water pressure regulator valve. Fig. 3 5. C  lose drain port (screwdriver slot perpendicular to drain port). 0939 Expansion Tank Port 4. U  sing a suitable air pressure gauge, check expansion tank air charge level via the tank’s Schrader valve and adjust as needed. Important note - see expansion tank manufacturer’s instructions for additional information on charging expansion tank! The air pressure charge should match the system fill pressure (water pressure regulator valve) setting. If replacing tank, remove old tank and install new tank. Check air charge in new tank and adjust if needed. 1. F  ollow the entire Function 1 procedure above to set expansion tank air charge to match desired fill pressure level. 3. S  lowly open drain port by turning the drain port valve to the open position (screwdriver slot parallel to drain port) to relieve pressure on expansion tank diaphragm. 2. M  ake certain RBFF drain port is closed – the screwdriver slot must be perpendicular to the drain port. Slowly remove cover from drain port and attach hose. 4. Slowly open supply line valve to water pressure regulator valve. 1. P  ush in and turn RBFF handle 90° counterclockwise and lock into the expansion tankport-closed position as shown in Figure 4. Function 1 - Expansion Tank Replacement/Air Charge Maintenance Function 2 - Water Pressure Regulator Valve Service/Replacement Normal Operation IS-RBFF Fig. 2 Fig. 1 Drain Port Cover Drain Port Valve Fill Port System Port Important Note: A shutoff valve must be installed on the cold water line upstream of the water pressure regulator valve and backflow device! 3. T  he water pressure regulator valve may be installed directly to the 1/2" male thread of the RBFF fill port. The use of a backflow prevention device such as the Watts 9D is recommended – check local codes for backflow prevention requirements. 2. Install the expansion tank in the bottom 1/2" female expansion tank port of the RBFF. 1. P  ipe the system port of the RBFF into the bottom tapping of the air separator using a 1/2" black or brass nipple. The RBFF can be installed with the valve handle and pressure gauge facing in any direction - select a 1/2" nipple length appropriate for the installation and tighten until positioned for easy access and/or piping considerations. Be sure to allow enough room for operation of the water pressure regulator valve fast-fill lever. Installation Instructions Model RBFF Residential Boiler Fill Fitting should be installed in closed-loop hot water heating systems as per the piping diagram shown in the Figure 1. Refer to Figure 2 for RBFF port identification. IS-RBFF Model RBFF Modelo RBFF Modèle RBFF Residential Boiler Fill Fitting Empalme para el llenado de calderas residenciales Accessoire de remplissage pour chaudière domestique Size: 1⁄2" (15mm) Tamaño: 1⁄2 pulg. (15 mm) Diamètre : 1⁄2 po (15 mm) Installation Instructions Instrucciones de instalación Instructions d’installation RBFF © Watts, 2009 INSTRUCCIONES EN ESPAÑOL El empalme para el llenado de calderas residenciales modelo RBFF debe instalarse en los sistemas de calefacción con agua caliente en ciclo cerrado según el diagrama de tuberías que se muestra en la Figura 1. Consulte la Figura 2 para la identificación de los puertos del RBFF. Instrucciones de instalación 1. C  onecte el puerto del sistema del RBFF en la conexión intermedia inferior del separador de aire con conector negro o de latón de 1/2 pulg. El RBFF puede instalarse con el monomando de la válvula y el medidor de presión hacia cualquier dirección. Seleccione un conector de 1/2 pulg. de una longitud adecuada para la instalación y ajuste hasta que quede en posición para un fácil acceso y/o consideraciones de la tubería. Asegúrese de permitir espacio suficiente para la operación de la palanca de llenado rápido de la válvula reguladora de presión del agua. 2. Instale el tanque de expansión en el puerto de tanque de expansión hembra inferior de 1/2 pulg. del RBFF. 3. E  s posible instalar la válvula reguladora de la presión de agua directamente en la rosca macho de 1/2 pulg. del puerto de llenado del RBFF. Se recomienda usar un dispositivo de prevención de reflujo como el Watts 9D. Consulte los códigos locales para ver los requisitos de prevención de reflujo. Nota importante: ¡Debe instalarse una válvula de cierre en el conducto de agua fría contra la corriente de la válvula reguladora de la presión de agua y del dispositivo de reflujo! Puerto del sistema Puerto de llenadot Válvula del puerto de drenaje Tapa del puerto de drenaje INSTRUCTIONS EN FRANçAIS Fig. 1 Fig. 2 Puerto del tanque de expansión L'accessoire RBFF de remplissage pour chaudière domestique doit être monté sur des systèmes de traitement de l'eau chaude en circuit fermé, en accord avec le schéma de tuyauterie (Fig. 1). Se référer à la Figure 2 au sujet des orifices. Instructions d’installation 1. A  vec un tuyau, raccorder l'orifice-système de l'accessoire RBFF au taraudage inférieur du séparateur d'air (utiliser un mamelon en laiton ou noir de 1/2 po). Le RBFF peut être monté avec le robinet et le manomètre tournés dans n'importe quelle direction – choisir un mamelon de 1/2 po de diamètre et de longueur adéquate selon le montage, puis orienter en serrant, en vue de faciliter l'accès ou la pose de la tuyauterie. Veiller à laisser suffisamment d'espace pour le levier de remplissage rapide du régulateur de pression d'eau. 2. F  ixer le réservoir de dilatation à l'orifice-réservoir de dilatation de 1/2 po (partie inférieure du RBFF). 3. L  e régulateur de pression d'eau peut être fixé directement au filetage extérieur de 1/2 po de l'orifice-remplissage du RBFF. Il est conseillé d'utiliser un dispositif de non-retour, tel le 9D de Watts – prendre connaissance des exigences des codes locaux à ce sujet. Avis important : Un robinet d'arrêt doit être posé sur la conduite d'eau froide, en amont du régulateur de pression d'eau et du dispositif de non retour ! Orificesystème Fig. 1 Fig. 2 Durante el funcionamiento normal del sistema de calefacción, el monomando de la válvula del RBFF debe estar trabado en la posición de todos los puertos abiertos, tal como se muestra en la Figura 3, con el puerto de drenaje cerrado (ranura de destornillador perpendicular al puerto de drenaje) y la tapa del puerto de drenaje debe estar instalada. Para operar la válvula, presione para destrabar el monomando accionado por resorte de la pestaña con traba. El monomando puede girarse en ambas direcciones y saldrá y se trabará en las cuatro posiciones que se muestran en las figuras 3 a 6. La protuberancia corta indica que el puerto está cerrado; las alas largas indican que los puertos están abiertos. 4. P  resione y gire el monomando del RBFF 90° en sentido antihorario y trábelo en la posición de todos los puertos abiertos, tal como se muestra en la Figura 3, para que el sistema esté nuevamente en operación. 6. Q  uite la manguera del puerto de drenaje y reinstale la tapa del puerto de drenaje. Fig. 3 7. P  resione y gire el monomando del RBFF 90° en sentido horario y trábelo en la posición de todos los puertos abiertos, tal como se muestra en la Figura 3, para que el sistema esté nuevamente en operación. Función 2 – Mantenimiento/ reemplazo de la válvula reguladora de la presión de agua 1. P  resione y gire el monomando del RBFF 90° en sentido horario y trábelo en la posición de puerto del sistema cerrado, tal como se muestra en la Figura 6. Fig. 5 1. P  resione y gire el monomando del RBFF 90° en sentido antihorario y trábelo en la posición de puerto de tanque de expansión cerrado, tal como se muestra en la Figura 4. 2. A  segúrese de que el puerto de drenaje del RBFF esté cerrado. La ranura de destornillador debe estar perpendicular al puerto de drenaje. Quite lentamente la tapa del puerto de drenaje y conecte la manguera. 3. Realice el mantenimiento/reemplace la válvula reguladora de la presión de agua. 2. C  ierre la válvula de aislamiento del conducto de agua fría a la válvula reguladora de la presión de agua. 4. Abra lentamente la válvula del conducto a la válvula reguladora de la presión de agua. 3. A  bra lentamente el puerto de drenaje girando la válvula del puerto de drenaje a la posición abierta (ranura de destornillador paralela al puerto de drenaje) para dejar salir la presión del diafragma del tanque de expansión. Fig. 4 En service normal du système de chauffage, le robinet du RBFF doit être verrouillé en position « tous les orifices ouverts » (cf. Figure 3), exception faite de l'orifice de vidange qui doit être fermé (fente de tournevis perpendiculaire à cet orifice) et bouché par la mise en place de son couvercle. Pour régler le robinet, l'enfoncer d'abord pour le libérer de la patte de verrouillage ; le tourner ensuite dans un sens ou dans l'autre, puis le relâcher : il remontera et se verrouillera dans l'une des quatre positions (Figures 3 à 6). (La pièce courte indique l'orifice fermé ; les longues ailettes indiquent les orifices ouverts). 2. P  resione y gire el monomando del RBFF y trábelo en la posición de puerto del sistema cerrado tal como se muestra en la Figura 6. 5. C  ierre el puerto de drenaje (ranura de destornillador perpendicular al puerto de drenaje) y lea la presión del medidor de presión del RBFF. 6. R  epita los pasos 2 a 5 según sea necesario para lograr la presión de llenado deseada. 7. Quite la manguera del puerto de drenaje y reinstale la tapa del puerto de drenaje. 8. S  iga todos los pasos de la sección correspondiente a la Función 1 anterior para restablecer la carga de aire del tanque de expansión con el fin de que coincida con la configuración de la válvula reguladora de la presión de agua. Fonction 2 - Réparation/ remplacement du régulateur de pression d'eau Otras funciones El puerto de drenaje de la válvula esférica también puede usarse para otras operaciones de drenaje y llenado. El monomando del RBFF generalmente estará con una rotación de 180° y trabado en la posición de puerto de llenado cerrado para estas operaciones. 1. E  nfoncer le robinet du RBFF et le tourner à 90° dans le sens horaire en position « orificesystème fermé » (cf. Figure 6). Relâcher pour verrouiller. 2. T  ourner la vis de réglage du régulateur pour diminuer la pression. Fig. 5 1. E  nfoncer le robinet du RBFF et le tourner à 180° ; relâcher et verrouiller en position « orificeremplissage fermé » (cf. Figure 5). 2. F  ermer le robinet d'isolement sur la conduite d'arrivée d'eau froide vers le régulateur de pression d'eau. 3. Réparer/remplacer le régulateur. 4. Ouvrir lentement le robinet d'arrivée d'eau vers le régulateur. 5. E  nfoncer le robinet du RBFF et le tourner à 180° ; relâcher et verrouiller en position « tous les orifices ouverts » (cf. Figure 3) pour remettre le système en service. Fonction 3 - Réglage du régulateur de pression d'eau Pour augmenter la pression de remplissage du système : 1. S  uivre toute la procédure Fonction 1 ci-dessus, afin de régler la charge d'air du réservoir de dilatation en accord avec le niveau de pression de remplissage souhaité. Fig. 4 4. A  bra lentamente el puerto de drenaje (ranura de destornillador paralela al puerto de drenaje) hasta que comience a llenarse la válvula reguladora de la presión de agua. Pour diminuer la pression de remplissage du système : 7. E  nfoncer le robinet du RBFF et le tourner à 90° dans le sens horaire ; relâcher et verrouiller en position « tous les orifices ouverts » (cf. Figure 3) pour remettre le système en service. 2. S  'assurer que l'orifice de vidange du RBFF est bien fermé : la fente de tournevis doit être perpendiculaire à cet orifice. Enlever délicatement le couvercle de l'orifice, puis y raccorder un tuyau flexible. 3. A  segúrese de que el puerto de drenaje del RBFF esté cerrado. La ranura de destornillador debe estar perpendicular al puerto de drenaje. Quite lentamente la tapa del puerto de drenaje y conecte la manguera. 4. E  nfoncer le robinet du RBFF et le tourner à 90° dans le sens anti-horaire ; relâcher et verrouiller en position « tous les orifices ouverts » (cf. Figure 3) pour remettre le système en service. 6. R  etirer le tuyau flexible de l'orifice, puis remettre son couvercle. 1. E  nfoncer le robinet du RBFF et le tourner à 90° dans le sens anti-horaire ; relâcher et verrouiller en position « orifice-réservoir de dilatation fermé » (cf. Figure 4). 4. À  l'aide d'un contrôleur adéquat de pression d'air, vérifier le niveau de charge d'air du réservoir par la vanne Schrader de celui-ci. Régler au besoin. Avis important - Consulter les instructions du fabricant du réservoir de dilatation pour obtenir des informations complémentaires sur le chargement du réservoir ! La charge d'air doit correspondre au réglage de remplissage-pressurisation du système (régulateur de pression d'eau). En cas de 1. S  iga todo el procedimiento de la Función 1 anterior para configurar la carga de aire del tanque de expansión para que coincida con el nivel de presión de llenado deseado. 5. F  ermer l'orifice de vidange (fente de tournevis perpendiculaire à cet orifice). Fonction 1 - Remplacement Fig. 3 du réservoir de dilatation/Entretien de la charge d'air 2. G  ire el tornillo de ajuste de la válvula reguladora de la presión de agua para reducir la presión. Para aumentar la presión de llenado del sistema: remplacement, retirer le réservoir usé et poser un réservoir neuf. Vérifier la charge d'air dans le nouveau réservoir et régler au besoin. Service normal Robinet de vidange 5. P  resione y gire el monomando del RBFF 180° en sentido horario y trábelo en la posición de todos los puertos abiertos, tal como se muestra en la Figura 3, para que el sistema esté nuevamente en operación. Función 3 – Ajuste de la válvula reguladora de la presión de agua 4. C  on un medidor de presión de aire adecuado, verifique el nivel de carga de aire del tanque de expansión mediante la válvula Schrader del tanque y ajuste según sea necesario. Nota importante: ¡Consulte las instrucciones del fabricante del tanque de expansión para ver información adicional sobre cómo cargar el tanque de expansión! La carga de presión de aire debe coincidir con el parámetro de la presión de llenado del sistema (válvula reguladora de la presión de agua). Si está reemplazando el tanque, quite el tanque antiguo e instale el nuevo tanque. Verifique Fig. 6 Para disminuir la presión de llenado del sistema: 1. P  resione y gire el monomando del RBFF 180° y trábelo en la posición de puerto de llenado cerrado tal como se muestra en la Figura 5. 3. O  uvrir l'orifice de vidange, en tournant lentement son robinet en position ouverte (fente de tournevis parallèle à l'orifice de vidange), afin de diminuer la pression sur la membrane du réservoir de dilatation. Orifice-réservoir de dilatation 3. C  on el medidor de presión del RBFF como referencia, ajuste la válvula reguladora de la presión de agua en el nivel deseado. 5. C  ierre el puerto de drenaje (ranura de destornillador perpendicular al puerto de drenaje). Función 1 – Reemplazo del tanque de expansión/ mantenimiento de la carga de aire Orificeremplissage Couvercle de l'orifice de vidange la carga de aire del nuevo tanque y ajústela de ser necesario. Funcionamiento normal 2. E  nfoncer le robinet du RBFF et le tourner en position « orifice-système fermé » (cf. Figure 6). Relâcher pour verrouiller. 3. E  n se référant au manomètre du RBFF, régler le régulateur de pression d'eau au niveau souhaité. Fig. 6 3. S  'assurer que l'orifice de vidange du RBFF est bien fermé : la fente de tournevis doit être perpendiculaire à cet orifice. Enlever délicatement le couvercle de l'orifice, puis y raccorder un tuyau flexible. 4. O  uvrir lentement l'orifice de vidange (fente de tournevis parallèle à cet orifice), jusqu'à ce que le régulateur commence à se remplir. 5. F  ermer l'orifice de vidange (fente de tournevis perpendiculaire à cet orifice), puis constater la pression indiquée par le manomètre du RBFF. 6. Répéter au besoin les étapes 2 à 5 pour établir la pression souhaitée. 7. Retirer le tuyau flexible de l'orifice, puis remettre son couvercle. 8. S  uivre toutes les étapes de la Fonction 1 ci-dessus pour rétablir la charge d'air du réservoir de dilatation au réglage correspondant du régulateur de pression d'eau. Autres fonctions L'orifice de vidange avec robinet à tournant sphérique est utile dans plusieurs activités de vidange et de remplissage. Normalement, le robinet du RBFF sera alors tourné à 180° et verrouillé en position « orifice-remplissage fermé » pour permettre ces activités.