Wavetek Meterman 220 Manual de usuario

Categoría
Multimetros
Tipo
Manual de usuario

Este manual también es adecuado para

WARRANTY
The 220 Digital Multimeter is warranted against any defects of material or workmanship
within a period of one (1) year following the date of purchase of the multimeter by the original
purchaser or original user.
Any multimeter claimed to be defective during the warranty period should be returned with
proof of purchase to an authorized Wavetek Meterman Service Center or to the local Wavetek
Meterman dealer or distributor where your multimeter was purchased. See maintenance
section for details.
Any implied warranties arising out of the sale of a W
avetek Meterman multimeter, including
but not limited to implied warranties of merchantability and fitness for a particular purpose, are
limited in duration to the above stated one (1) year period. W
avetek Meterman shall not be
liable for loss of use of the multimeter or other incidental or consequential damages,
expenses, or economical loss or for any claim or claims for such damage, expenses or
economical loss.
Some states do not allow limitations on how long implied warranties last or the exclusion
or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
D GEWÄHRLEISTUNG
Die Digitale Multimeter Modelle 220 ist ab Kaufdatum für ein (1) Jahr gegen Material- und
Herstellungsfehler gewährleistet. Siehe Kapitel "Unterhalt und Reparatur" für Einzelheiten.
Implizierte Schadeforderungen sind auch auf ein Jahr beschränkt. W
avetek Meterman ist nicht
ansprechbar für Gebrauchsverluß oder Folgeschäden, Ausgaben, Gewinnverluß, usw
.
E GARANTIA
Este Multímetro Digitale Modelo 220 está garantizado contra cualquier defecto de material
o de mano de obra durante un periodo de un (1) año contado a partir de la fecha de
adquisición. En la sección de "Mantenimiento y Reparación" se explican los detalles relativos
a reparaciones en garantía.
Cualquier otra garantía implícita está también limitada al periodo citado de un (1) año.
Wavetek Meterman no se hará responsable de pérdidas de uso del multí metro, ni de ningún
otro daño accidental o consecuencial, gastos o pérdidas económicas, en ninguna reclamación
a que pudiera haber lugar por dichos daños, gastos o pérdidas económicas.
F GARANTIE
Le multimètre digitaux, Modèle 220 est garanti pour un (1) an à partir de la date d’achat
contre les défauts de matériaux et de fabrication. Voir chapitre "Maintenance et Réparation"
pour plus de détails.
T
oute garantie impliquée est également limitée à un an. Wavetek Meterman ne peut être
tenu responsable pour perte d’utilisation ou autres préjudices indirects, frais, perte de
bénéfice, etc.
220.Man.08.00 9/11/00 6:05 PM Page 3
Introduction ........................................................ 2
Safety Information ............................................... 3
Instrument Familiarization ................................... 5
Measurement Procedures ................................. 10
Menu Functions ................................................ 21
Test Leads and Accessories ............................... 28
Specifications ....................................................29
Maintenance and Repair ................................... 36
D • Inhalt
Einleitung .............................................................2
Sicherheitsinformationen......................................4
Vorstellung des Gerätes. ......................................5
Meßprozeduren ................................................. 11
Menü-Funktionen .............. ............................... 21
Meßkabel und Zubehör......... ............................. 28
Spezifikationen ....................... .......................... 31
Wartung und Reparatur ..................................... 36
E • Contenidos
Introducción ........................ ............................... 2
Información de seguridad ...... ............................. 4
Familiarización con el instrumento.... ...................5
Procedimientos de medida ....... ........................ 11
Funciones de menú ................. ......................... 21
Puntas de prueba y accesorios . ........................ 28
Especificaciones ...................... ..........................32
Mantenimiento y reparación ..... ........................ 36
F • Contenu
Introduction........................... ...............................3
Informations de Sécurité ..................................... 5
Présentation de l’Appareil ......... .......................... 5
Procédures de Mesure ...................................... 11
Fonctions de Menu.............................................21
Câbles de Mesure et Accessoires ... .................. 29
Spécifications .............................. ..................... 33
Maintenance et Réparation ................................ 36
- 1 -
CONTENTS
SYMBOL DEFINITIONS
D • Erklärung der Symbole = E • Significado de los símbolos = F • Explication des Symboles
Attention! Refer to Operating Instructions •D• Achtung! Bitte Anleitung lesen •E•
¡Atención! Consulte las Instrucciones de Uso •F• Attention! Consultez le manuel.
Ground connection •D• Erdanschluß •E• Conexión a tierra
•F• Connection de terre.
Alternating current •D• Wechselstrom •E• Corriente alterna
•F• Courant alternatif.
Direct current •D• Gleichstrom •E• Corriente continua
•F• Courant continu.
Dangerous voltage may be present at terminals •D• Eine gefährliche Spannung kann an
den Eingängen anliegen •E• Puede haber tensión peligrosa en los terminales •F• Une
tension dangereuse peut être présente aux entrées.
Low battery symbol •D• Entladene Batterieanzeige •E• Símbolo de pila baja •F•
Symbole de pile déchargée.
Logic Test HIGH and LOW indicators •D• Logik Test HIGH und LOW Indikatoren •E•
Indicadores lógicos de prueba Alto (High) y Bajo (Low). •F• Indicateurs de test logique
HIGH et LOW.
Audio Alarm Indicator •D• Auditive Alarmanzeige •E• Indicador audible de alarma •F•
Indicateur d’alarme auditif.
Logic Pulse •D• Logikpuls •E• Pulso lógico •F• Impulsion logique.
This instrument has double insulation •D• Dieses Gerät ist doppelt geisoliert •E• Este
instrumento tiene doble aislamiento •F• Cet appareil est prévu d’une double isolation.
220.Man.08.00 9/11/00 6:05 PM Page 1
WARNINGS AND PRECAUTIONS
This instrument is EN61010-1 certified for Installation Class II, 1000V and
Class III, 600V. It is recommended for use in distribution level and fixed
installations, as well as lesser installations, and not for primary supply lines,
overhead lines and cable systems. All inputs are protected against continuous
overload conditions up to the limits of each function's stated input protection (see
specifications). Never exceed these limits
nor the ratings marked on the
INTRODUCTION
The digital multimeter 220 is a 3-3/4 digit, autoranging, AC-coupled, average
measuring & RMS reading instrument that measures voltage, current, resistance,
continuity, diode junctions, TTL and logic. Menu selection allows Range Lock,
Probe Hold
TM
, Relative Measurement, Auto Min Max Avg Measurement and
backlight on/off. The instrument is completely sealed.
D • Einleitung
Das Modell 220 ist ein 3-3/4-stelliges AC-gekoppeltes, mittelwert- messendes
Digitalmultimeter mit automatischer Bereichswahl. Es mißt Spannung, Strom,
Widerstand und Durchgang und führt Diodentest, TTL- und Logiktest aus. Eine
Menüwahl umfaßt Bereichssperre, Meßwertspeicher, Relativmessung, Auto Min
Max Avg und Anzeigen-Hintergrundbeleuchtung. Das Gerät ist vollständig
abgedichtet.
E • Introducción
El multímetro digital 220 es un instrumento de medidade 3-3/4 dígitos, trabajando
en alterna, con autorango, indicando las lecturas en valor medio y RMS, pudiendo
medir voltajes, corriente, resistencia, continuidad, diodos, uniones y lógica de tipo
TTL. El selector de menús permite el bloqueo de rango, retención del valor medido,
medición relativa, medición media, auto, mínima, máxima y apagado automático de
la iluminación de pantalla. El instrumento está completamente sellado.
D • Introduction
Le modèle 220 de est un multimètre numérique 3-3/4 digits à sélection
automatique des gammes, mesurant la valeur moyenne avec couplage CA. Il
mesure la tension, le courant, la résistance et la continuité, et effectue des tests de
diodes et de logique. Un menu de fonctions comprend le bloquage de gamme, le
maintien de lecture, la mesure relative, Auto Min Max Avg et un rétro-éclairage de
l’afficheur. L’instrument est complètement étanche.
- 2 -
220.Man.08.00 9/11/00 6:05 PM Page 2
- 4 -
isolieren ! Das Gerät nicht mit der Trageschlaufe am eigenen Körper befestigen.
Bei Strommessung, Multimeter immer in Serie schalten – Nie in parallel mit
Spannungsquelle.
Sicherung immer mit gleichwertiger ersetzen.
Gerät nicht in
explosiver Umgebung verwenden.
E • Advertencias y Precauciones
Este instrumento está homologado según EN61010-1/CE para la Categoría de
Instalación II - 1000V o Categoría de Instalación III - 600V. Su uso está
recomendado en el nivel de distribución y en instalaciones fijas, así como en
instalaciones menores, pero no en líneas principales de suministro, líneas aéreas
ni sistemas de cable.
No supere nunca los límites de entrada para las diferentes
funciones (vea Especificaciones), ni los límites marcados en el instrumento.
Para
medidas de tensión, el circuito sometido a prueba debe estar protegido con un
fusible de 20 A o un disyuntor.
Tenga especial cuidado al: medir tensión >20 V //
corriente >10 mA // tensión de red de CA con cargas inductivas // tensión de red de
CA durante tormentas eléctricas // corriente, si salta el fusible en un circuito con
tensión de circuito abierto >600 V (500 V en la entrada de mA) // trabajar con
pantallas TRC nInspeccione siempre el multímetro, las puntas de prueba, los
conectores y los accesorios antes de cada uso. No utilice ningún componente que
esté dañado.
No se ponga Ud. a tierra cuando esté tomando medidas, y no toque
nunca partes expuestas de los circuitos. No utilice la cinta "Flex-Strap" para sujetar
el multímetro a su cuerpo.
Al medir corriente, conecte siempre el multímetro EN
SERIE con la carga - NUNCA EN PARALELO con una fuente de tensión.
Nunca
sustituya un fusible con otro que no tenga las mismas especificaciones.
No utilice
el instrumento en ambientes potencialmente explosivos.
F • Avertissements et Précautions
Cet instrument est certifié EN61010-1/CE catégorie d’installation II, 1000 ou
catégorie III, 600V. Son utilisation est recommandée pour le niveau de distribution
de réseau, les installations fixes et systèmes subordonnés, et non pour les
installations de puissance et lignes de transmission et câblages à haute tension.
N’excédez jamais les limites de surcharge continues (voir spécifications) ou
d’autres limites marquées sur l’appareil. nPour les mesures de tension, le circuit
sous mesure doit être protégé par un fusible 20A ou par un disjoncteur.
Soyez très
prudent quand vous mesurez des tensions >20V ou des courants >10mA // tension
ou courant de secteur avec charge inductive ou par temps de tempête // du courant
quand le fusible saute dans un circuit avec tension en circuit ouvert de >600 volts
(>500V pour l’entrée mA) // dans des appareils à tube cathodique (transitoires à
haute tension) nInspectez appareil, câbles, connecteurs avant chaque mesure.
220.Man.08.00 9/11/00 6:05 PM Page 4
- 5 -
N’utilisez pas des pièces endommagées
Ne touchez pas les pointes de touche ou
le circuit pendant les mesures. Isolez-vous ! N’utilisez pas la boucle de suspension
pour attacher l’appareil à votre propre corps.
Pour la mesure de courant, connectez
l’appareil en série avec le circuit – JAMAIS en parallèle avec une source de tension.
Remplacez les fusibles toujours par des fusibles équivalents
N’utilisez pas cet
appareil dans des atmosphères explosives.
PREPARATION FOR USE – UNPACKING
Your shipping carton should include the multimeter, a holster, one test lead set
(one black, one red), one 9V battery (installed) and this manual. If any of the items
are damaged or missing, immediately return the complete package to the place of
purchase for an exchange.
D • Gebrauchsvorbereitung - Auspacken
Die Verpackung sollte enthalten: ein Multimeter, ein Schutzholster, ein Meßkabelsatz
(ein schwarz, ein rot), eine 9V Batterie (im Gerät) und diese Anleitung. Wenn ein Teil
fehlt oder beschädigt ist, bitte bei der Verkaufstelle umtauschen.
E • Preparación del multímetro para su uso - Desembalaje
El embalaje debe contener: el multímetro, una funda, un juego de puntas de prueba
(una negra y otra roja), una pila de 9 V (instalada), y este manual. Si falta algún
componente u observa daños, devuelva el conjunto al lugar donde lo adquirió para
que se lo cambien.
F • Préparation pour l’Emploi - Déballage
Votre emballage doit contenir: un multimètre, une gaine de protection, un jeu de
câbles de mesure (un rouge, un noir), une pile 9V (installée) et ce manuel. Si une
pièce manque ou est endommagée, retournez à votre point de vente pur un échange.
PROTECTIVE HOLSTER
The holster/tilt stand protects the meter from accidental falls and provides greater
ease of use. Both test lead probes can be attached to the holster for storage. One
probe can be attached for measurement, holding the meter with probe in one hand
and the second probe in the other hand.
D • Schutz-Holster
Das Schutzholster schützt das Gerät vor Stürzen und Stößen. Die Meßspitzen können
am Holster befestigt werden.
220.Man.08.00 9/11/00 6:05 PM Page 5
- 6 -
3-3/4 digit LCD with unit indicators
3-3/4 Digit LCD mit Einheitsanzeigen
LCD de 3-3/4 dígitos; indicadores de
unidades
LCD 3-3/4 digits; indicateurs d’unités
Low Battery, (p. 8)
Batterie entladen (S. 8)
Pila baja (p. 8)
Pile déchargée (p. 8)
Function/Range Selector,
Funktions-/Bereich-
Schalter
Selector de
Función/Escala
Sélecteur fonctions/
calibres
FUSED
MAX
430mA
MAX
mA
10A
VCOM
CAT II1000V
CAT III 600V
FUSED
10A MAX
1000V
750V
OFF
V
V
430
u
A
LOGIC
430
mA
43
mA
10A
REL RANGE
HOLD
220
MEM
A
DC
RANGE
AC
mVmV
muAmuA
MkMk
APOAPO
LOGIC MEM REC MAX MIN ALOGIC MEM REC MAX MIN AVG HOLDVG HOLD
SLEEP
OFF
MIN MAX
Menu Functions, see page 21
Menübalken – siehe “Menüfunktionen”, Seite 21
Barra de menú - ver “Funciones de menú”, página 21
Barre de menu - voir “Fonctions de Menu”, page 21
Menu Buttons, (p. 21)
Menutasten (S. 21)
Teclas de menú
(p. 21)
Boutons de menu
(p. 21)
High input for voltage
and resistance (p. 12)
V- Eingang. Hoch
für Spannung und
Widerstand (S. 12)
Entrada “alta” para
tensión y resistencia
(p. 12)
Entrée V-. Haut
pour tension et
résistance (p. 12)
COM Input – common or low input for all measurements (p. 12)
COM Eingang – Referenzpunkt für alle Messungen (S. 12)
COM- entrada común o “baja” para todas las medidas (p. 12)
Entrée COM – commun ou bas pour toutes mesures (p. 12)
10A Input (p. 13)
10A Eingang (S. 13)
Entrada 10A (p. 14)
Entrée 10A (p. 15)
430mA Input (p. 13)
430mA Eingang (S. 13)
Entrada 430mA (p. 14)
Entrée 430mA (p. 15)
220.Man.08.00 9/11/00 6:05 PM Page 6
manueller Bereichswahl - RANGE LOCK - Fig. 1): "I.OL" Anzeige. Höheren Bereich
wählen oder Messung unterbrechen.
Anmerkung: Überlastanzeige (ohne Ton) ist normal bei Widerstands- und
Durchgangsmessung wenn Meßkabel-spitzen offen sind oder wenn der Meßwert den
Bereich überschreitet. Bei Logikmessung ist die Überlastanzeige (ohne Ton)
permanent.
Eingangswarnung: (Fig. 2) "FErr" wird angezeigt wenn ein Meßkabel mit dem mA
oder 10A Eingang verbunden ist, der Wahlschalter jedoch nicht auf der richtigen
Stromfunktion steht. (Würde mit dem Stromeingang Spannung gemessen werden,
dann könnte ein sehr hoher Strom im Gerät entstehen). Alle Strombereiche sind mit
flinken Sicherungen geschützt.
Entladene Batterieanzeige (Fig. 3) : Bei dieser Anzeige sind weniger als 50
Betriebsstunden möglich. Die Geanuigkeit ist nicht länger garantiert.
E • Indicación de sobrecarga
La sobrecarga de entrada (en la escala superior en caso de selección
automática de escala) se indica mediante "I.OL" y un tono continuo. Desconecte las
puntas de prueba del circuito de medida, ya que el nivel de entrada es superior a la
capacidad del medidor.
La sobrecarga del visualizador (la entrada supera la capacidad de la escala
seleccionada en modo manual) también se indica mediante "I.OL". Seleccione una
escala más ata. Si ya está en la más alta, interrumpa la medida.
Nota: La condición de sobrecarga (sin sonido) es normal en los rangos de Ohmios,
continuidad y lógica. Aparece cuando las puntas de prueba en las escalas de ohmios
y continuidad no están conectadas a ningún componente, o cuando el valor medido,
es mayor que el rango de resistencia elegido. Está permanentemente encendida
cuando se elige la función lógica.
Aviso de Entrada Incorrecta: El visualizador muestra un código de error "FErr"
cuando se inserta una punta de prueba en la entrada de mA o 10 A y el selector no
está posicionado en el valor correcto de corriente. (Si se conecta el multímetro a una
fuente de tensión con las puntas en la entrada de corriente, podría exponer el
instrumento a corrientes muy elevadas). Todas las escalas de corriente están
protegidas mediante fusibles de acción rápida.
Batería baja: Cuando el indicador de batería baja aparece en pantalla, la batería
tiene menos de 50 horas de operatividad y la precisión del medidor no puede ser
garantizada.
- 8 -
220.Man.08.00 9/11/00 6:05 PM Page 8
D • Akustische Anzeigen
Das Gerät gibt einen Einzelton ab bei Funktionswechsel, bei Aktivierung einer
"validen" Taste und wenn neue Anzeigenspeicherwerte erfaßt werden. Ein Dauerton
wird abgegeben bei Eingangsüberlast, bei Durchgangsmessung, wenn der
Widerstand unter 50 liegt und beim Messen im 10 Bereich, wenn der
Eingangsstrom 10A überschreitet.
E • Avisos audibles
El medidor emite un solo pitido, cuando se cambia un parámetro, se debe pulsar la
tecla "valid" del panel frontal ya que en caso de hacerlo, los valores medidos son
actualizados. El medidor emite un tono continuo en caso de sobrecarga de entrada, y
midiendo continuidad cuando el valor de la resistencia es <50. Cuando se usa la
entrada de 10 A, el medidor emite un tono continuo si la corriente supera los 10 A.
F • Indication Sonore
L’instrument émet un bip sonore en cas de changement de fonction, quand un
bouton valide est pressé ou une nouvelle valeur est enregistrée en Probe Hold. Un
signal sonore continu indique un dépassement de la limite d’entrée, une résistance
inférieure à 50en mesure de continuité, ou un courant supérieur à 10A en mesure
de courant (avec l’entrée 10A).
- 10 -
MEASURING PROCEDURES
GENERAL: Turn instrument on by turning function/range switch away from OFF
and selecting the parameter you want to measure.
Ranging: This instrument is autoranging on all Volts and Ohms ranges and
manual ranging on Amperes ranges. When in Volts and Ohms ranges, it auto-
matically selects the range that gives the best resolution for the measured value. A
range can be locked through menu selection (see Menu Functions, page 24). You
can tell which range you are in by the position of the decimal point and the
measurement unit displayed.
General Measurement Procedures: When connecting or disconnecting
test leads to a circuit, always turn off power to device or circuit being tested and
discharge all capacitors. Strictly observe the max input limits. Do not
change functions while test leads are connected to circuit.
D • Meßprozeduren
Einschalten: Gerät einschalten durch Funktions-Bereichsschalter weg von OFF
nach der gewünschten Funktion drehen.
Bereichswahl: Dieses Gerät hat automatische Bereichswahl für Spannungs- und
Widerstandsmessung und manuelle Bereichswahl für Strommessung. Bei Spannung
und Widerstand wählt das Gerät automatisch den Bereich der die beste Auflösung
220.Man.08.00 9/11/00 6:05 PM Page 10
- 11 -
bietet. Ein Bereich kann durch Menüwahl festgehalten werden (siehe Menü-
funktionen, Seite 24). Der Dezimalpunkt und die angezeigte Einheit geben an in
welchem Bereich Sie sich befinden.
Allgemein:
Vor Verbinden und Trennen der Meßkabel mit dem Schaltkreis,
diesen abschalten und Kondensatoren entladen.
Maximale Grenzen nicht
überschreiten.
Keinen Funktionswechsel vornehmen während die Meßspitzen mit
dem Schaltkreis verbunden sind.
E • Procedimientos de medida
GENERAL: Encienda el instrumento, poniendo el selector de función/escala fuera
de OFF y seleccionando el parámetro que desee medir.
Escalas: Este instrumento funciona en modo autorango para mediciones de voltaje
y ohmios y en modo manual en las mediciones de amperios. Cuando se trabaja en
voltios y ohmios, el aparato selecciona de forma automática el rango de mejor
resolución para el valor medido. Es posible fijar una escala desde el menú (vea
Funciones de menú, pág. 24). La escala en que está en un momento dado puede
determinarse por la posición del punto decimal y las unidades de medida.
Procedimientos generales:
Antes de conectar o desconectar las puntas de
prueba a/de un circuito, apague siempre el dispositivo o circuito sometido a prueba
y descargue todos los condensadores.
Observe estrictamente los límites
máximos de entrada.
No cambie de función mientras las puntas de prueba estén
conectadas a un circuito.
F • Procédures de Mesure
Mise sous tension: Allumez l’appareil en tournant le sélecteur de fonctions à
partir de OFF vers le paramètre à mesurer.
Sélection des gammes: La sélection de gammes est automatique pour les
mesures de tension et de résistance, et manuelle pour la mesure de courant. En
mesure de tension et de résistance, l’appareil choisit automatiquement le gamme qui
offre la meilleure résolution. Une gamme peut être bloquée par sélection de menu
(voir page 24). Le point décimal et l’unité affichée indiquent la gamme dans laquelle
vous mesurez.
Général:
Avant de connecter ou de déconnecter les cordons de test, coupez
l’alimentation du circuit à mesurer et déchargez les condensateurs.
Ne dépassez
pas les limites d’entrée.
Ne changez pas de fonction tandis que les pointes de
touche sont connectées au circuit.
220.Man.08.00 9/11/00 6:05 PM Page 11
- 14 -
FUSED
MAX
430mA
MAX
mA
10A
VCOM
CAT II1000V
CAT III 600V
FUSED
10A MAX
1000V
750V
OFF
V
V
430
u
A
LOGIC
430
mA
43
mA
10A
REL RANGE
HOLD
220
MEM
A
DC
A
Discharge capacitors
Kondensatoren entladen
Descargue los condensadores
Décharger les condensateurs
3b
3a
3c
3d
2
1
4
5
red/rot/
roja/rouge
A or A
2a
SLEEP
OFF
MIN MAX
Fig. 5
E • Medidas de corriente CC y CA (DCA y ACA) -(vea Fig. 5)
Conecte la punta de prueba roja a la entrada de 430mA para medidas de corriente
hasta 430 mA, o a la entrada de 10 A para medidas de corriente hasta 10 A. Conecte
la punta de prueba negra a la entrada COM.
Seleccione el rango de amperios a
medirse y pulse la tecla para seleccionar si la medición es en alterna o
contínua. La indicación en el lado izquierdo de la pantalla cambia.
Abra el circuito
en el que vaya a medir la corriente. (la tensión entre este punto y tierra no
debe superar los 1000 V).
Conecte con seguridad las puntas de prueba, en serie
con la carga. Conecte la alimentación del circuito sobre el que va a medir.
Lea el
valor de la corriente en el visualizador.
Nota: Es posible medir entre 10 y 20 A durante un máximo de 30 segundos.
Después deje transcurrir 10 minutos para que se enfríe el instrumento.
Aviso de entrada incorrecta: Aparece "FErr" cuando se conecta una punta de
prueba a la entrada de corriente y el selector no está en escala de corriente correcta.
A
220.Man.08.00 9/11/00 6:05 PM Page 14
- 15 -
F • Mesure de Courant CC et CA (voir fig. 5)
Connectez le cordon rouge à l’entrée 430mA pour mesures jusqu’à 430mA et à
l’entrée 10A pour mesures jusqu’à 10A. Connectez le cordon noir à l’entrée COM.
Placez le sélecteur sur la gamme de courant appropriée et pressez le touche pour
mesurer du courant continu ou du courant alternatif. Observez l’affichage de AC (=
CA) et DC (= CC).
Ouvrez le circuit à mesurer (le potentiel à ce point par rapport à
la terre ne doit pas dépasser 1000V). Connectez les pointes de touche solidement
en série avec le circuit.
Mettez le circuit sous tension. Lisez la mesure.
Note: Si, dans la gamme de 10A, vous mesurez brièvement un courant supérieur à
10A, éteignez l’appareil, et laissez le refroidir pendant au moins 10 minutes.
Avertissement d’Entrée: "FErr" est affiché quand un cordon de test est relié à
une entrée de courant mais le sélecteur n’est pas mis sur la bonne gamme de
courant.
RESISTANCE MEASUREMENT (See Fig. 6)
Turn off any power to the circuit to be measured and discharge any capacitors.
Any voltage present during a resistance measurement will cause inaccurate
readings.Connect test leads as shown in figure 6. Set Function/Range Switch
to position. Connect test leads to circuit being measured. Read resistance
value on Digital Display. Open circuits will be displayed as “I.OL”.
Note: When measuring very low resistances, use Relative Measurement to
eliminate the test lead resistance (see Menu Functions, page 23).
D • Widerstandsmessung (siehe Fig. 6)
Jede Spannung vom Meßkreis abschalten und Kondensatoren entladen. Eine am
Meßkreis anliegende Spannung würde das Resultat verfälschen.
Rotes Meßkabel
mit V• Eingang und schwarzes mit COM verbinden.
Funktionsschalter auf
- Position stellen.
Meßspitzen mit Widerstand/ Schaltkreis verbinden.
meßwert ablesen. Ein offener Schaltkreis wird mit Überlast angezeigt.
Anmerkung: Bei niedrigen Widerstandswerten mit Relativmessung (siehe Seite
23) den Widerstand der Meßkabel kompensieren.
E • Medidas de Resistencia (vea Fig.6)
Apague la alimentación eléctrica al circuíto que desea medir y descargue los
condensadores. La presencia de tensión causará imprecisión en las medidas de
resistencia.
Conecte la punta de prueba roja a la entrada V- y la negra a la
entrada COM.
Ponga el selector de función en la posición de . Conecte las
puntas de prueba a la resistencia o circuito que vaya a medir.
Lea el valor de la
resistencia en el visualizador. Un circuito abierto se indicará como condición de
sobrecarga.
220.Man.08.00 9/11/00 6:05 PM Page 15
- 18 -
D • Dioden- und Transistortest (siehe Fig. 7)
Der Diodentest zeigt den Spannungsabfall über den Diodendurchgang Rotes
Meßkabel mit V- Eingang und schwarzes mit COM Eingang verbinden.
Funktionsschalter auf stellen . Meßkabel mit Diode verbinden rotes mit
Anode; schwarzes mit Kathode.
Spannungsabfall in Durchlaßrichtung ablesen
(ung. 0.6V für eine Silizium-Diode und 0.4V für eine Germaniumdiode. Eine offene
Diode wird mit Überlast angezeigt.
Verbindung umdrehen um in Sperrichtung zu
messen. Überlast zeigt eine gute Diode an. Anmerkung: Überlast in beiden
Richtungen zeigt eine offene Diode an; eine niedrige Anzeige eine kurzgeschlossene
Diode. Transistorübergänge können wie Dioden getestet werden.
Bei Durchgangsmessung (auch bei kurzgeschlossenen Dioden) wird ein
Dauerton abgegeben wenn der Widerstand unter 50 fällt.
E • Comprobación de diodos y transistores (vea Fig.7)
En esta prueba se mide la caída de tensión en la unión del diodo. Conecte la
punta de prueba roja a la entrada V- y la negra a la entrada COM.
Ponga el
selector de función en la posición .
Aplique el extremo de la punta de
prueba roja al ánodo del diodo, y el de la negra al cátodo.
El visualizador indica la
caída de tensión directa (aproximadamente 0.6 V para diodos de silicio, o 0.4 V para
diodos de germanio). Una unión abierta se indica como condición de sobrecarga.
Invierta la conexión de las puntas de prueba para verificar la polarización inversa
del diodo. La condición de sobrecarga indica un diodo en buen estado. Notas: La
condición de sobrecarga en ambos sentidos indica un diodo abierto. Un valor bajo
de tensión en ambos sentidos indica un diodo cortocircuitado. Las uniones de un
transistor bipolar se comprueban como si fueran diodos.
Al medir continuidad (también diodos en cortocircuito), el medidor emite un
tono continuo si el valor de resistencia es inferior a 50 .
F • Test de Diodes et de Transistors (voir Fig. 7)
Le test de diodes affiche la chute de tension à travers la diode. Connectez le
cordon rouge à l’entrée V- et le noir à l’entrée COM.
Placez le sélecteur sur
.
Connectez les pointes de touche à la diode – le rouge à l’anode, le noir à
la cathode.
Lisez la chute de tension en direction passante (environ 0.6V pour
une diode au Si; 0.4V pour une diode au Ge). Une diode ouverte est affichée par
"IOL".
Inversez la connection pour mesurer en direction de bloquage. Une bonne
diode est affichée par "IOL". Notes: "IOL" dans les deux directions indique une
diode ouverte; une lecture basse indique une diode court-circuitée. Les jonctions de
transistors peuvent être testées comme des diodes.
Pour les mesures de continuité (et les diodes court-circuitées), l’instrument émet un
ton continu quand la résistance est inférieure à 50
Hz
A
V
A
%
V
Hz
A
V
A
%
V
Hz
A
V
A
%
V
220.Man.08.00 9/11/00 6:05 PM Page 18
D • Logiktest (siehe Fig. 8)
Der Logiktest zeigt ein TTL High, Low oder wechselndes Signal an.
Funktionsschalter auf Logiktest stellen. Die Anzeige zeigt IOL und das Wort
"Logic" an. Schwarzes Meßkabel mit Masse und rotes mit dem Meßpunkt
verbinden. Ein Logik Low Signal wird mit dem nach-unten-zeigenden Dreieck und
einem Ton angezeigt; ein Logik High Signal mit dem nach-oben-zeigendem Dreieck
ohne Ton, und ein wechselndes Signal mit wechselnden Dreiecken und Ton. Über
15Hz ist der Ton unterbrochen; über 100Hz wird der Ton ein Dauerton. Über 200Hz
bleiben beide Dreiecke angezeigt. Siehe " MEM" Fuktion zum Erfassen von
schnellen Impulsen und einmaligen Signalwechseln.
E • Test Lógico (vea Fig. 8)
El test lógico indica una entrada TTL alta, baja o en transición. Ponga el
interruptor de rango en la posición lógica. La pantalla mostrará un "I.0L" y la palabra
"Logic". Conecte la punta de prueba negra al común del circuíto o tierra y la punta
roja al punto de prueba. Aparecerá una indicación "LOW" con una flecha hacia abajo
junto a un tono cuando el nivel sea bajo y el caso inverso "HIGH", cuando el nivel
sea alto. Cuando la señal sea alternante, las flechas y los tonos cambiarán. Por
encima de los 15 Hz., el tono podría ser intermitente, cambiando a estable cuando la
frecuencia sea mayor de 100 Hz. Por encima de 200 Hz, las flechas permanecen
estables en pantalla. Consulte las instrucciones de las teclas " MEM" para
cuando se desea detectar pulsos rápidos y la espera en el cambio en los circuítos
monoestables, sin tener que observar el medidor.
F • Test Logique (voir fig. 8)
Le test logique indique un niveau logique (TTL) haut, bas ou changeant. Placez le
sélecteur sur la position "LOGIC". IOL et le mot "LOGIC" sont affichés. Connectez
le cordon noir à la masse et le rouge au point à mesurer. Un niveau bas est indiqué
par le triangle pointant vers le bas et un son; un niveau haut par le triangle pointant
vers le haut et sans son et un niveau changeant par des triangles changeants et un
son. En dessus de 15Hz le ton est intermittant – il devient continu au-dessus de
100Hz. Au-dessus de 200Hz les deux triangles sont affichés en permanence. Voir
fonction " MEM" pour la capture d’impulsions rapides et transitions uniques.
MENU FUNCTIONS
The model 220 meter has eight menu
buttons to select higher level
functions. All the buttons have an
LCD display indicator that is either
enabled, disabled or makes multiple
changes with each successive press
of that button. The use of each button
is explained on the following pages.
REL RANGE
HOLD
MEM
A
LOGIC MEM REC MAX MIN AVG HOLD
SLEEP
OFF
MIN MAX
- 20 -
220.Man.08.00 9/11/00 6:05 PM Page 20
D • Max-/Min-/Mittelwertspeicherung
Mit dieser Funktion werden minimale, maximale und Mittel-Werte in drei
verschiedenen Registern gespeichert, bei gleichzeitiger Anzeige des aktuellen
Wertes. Die Funktion steht für alle Meßfunktionen zur Verfügung, mit Ausnahme des
Logik Tests. Automatische Abschaltung ist inaktiv und das Gerät bleibt im
eingestellten Bereich.
Anmerkung: Falls gewünscht, wählen Sie mit der RANGE Menü Funktion einen
anderen Bereich bevor Sie die MINMAX Taste drücken. Stellen Sie den Wahlschalter
auf die gewünschte Meßfunktion und verbinden Sie die Meßkabel mit dem Meßkreis
(Siehe Beschreibung der Meßfunktionen). Drücken sie die MINMAX Taste um die
Funktion zu aktivieren. REC wird angezeigt. Führen Sie eine Messung aus über einen
längeren Zeitraum. Drücken Sie danach die MINMAX Taste einmal. REC MAX wird
angezeigt zusammen mit dem Inhalt des Maximalwert-Speichers. Drücken Sie die
MINMAX Taste ein zweites mal um den Wert des Minimalwertspeichers anzuzeigen
(REC MIN angezeigt). Eine folgende Aktivierung der Taste zeigt den Mittelwert der
letzten zehn Messungen bei zwei Messungen per Sekunde an (REC AVG angezeigt).
Benützen Sie diese Funktion wenn Signalrauschen eine sichere Messung erschwert.
Um die Funktion zu deaktivieren, drücken sie die Taste zwei Sekunden. Drücken Sie
RANGE zwei Sekunden um nach automatischer Bereichswahl zurück zu kehren.
E • Modo de grabación máximo/mínimo/valor medio
La tecla de "MINMAX", arranca una función de grabación que almacena tres
registros: máximo, mínimo y media, los cuales son actualizados de forma
permanente, pudiendo visualizarse en pantalla, hasta que la grabación se
desconecta. Esta característica, puede ser usada con todos los rangos de medición,
excepto con "Logic". Cuando se habilita "MINMAX" se desconecta la función de
apagado automático y el instrumento se bloquea en el rango actual.
Nota: Use el menú de rango (RANGE), antes de pulsar MINMAX para seleccionar
un rango diferente al actual.
Para usar, ponga el interruptor de rango en el parámetro a ser medido y conecte el
medidor al circuíto, como se indica en la sección GENERAL. A continuación pulse la
tecla "MINMAX", hasta que aparezca en pantalla "REC MAX". El parámetro síendo
medido mostrará la lectura máxima que la grabadora tiene en el registro MAX.
Vuelva a pulsar la tecla "MINMAX" para visualizar el contenido del registro MIN.
Cada vez que se pulse esta tecla la pantalla mostrará el registro siguiente en forma
de bucle contínuo. a lectura media mostrada es la media de las 10 últimas lecturas
realizadas a un ritmo de 2 por segundo. Utilice tambien esta posibilidad, cuando
existan ruídos en la línea y se hace difícil aparezca solamente la palabra "REC" la
- 22 -
220.Man.08.00 9/11/00 6:05 PM Page 22
E • Modo Relative
Haga primero la medida y después active Relative Mode, cuando la lectura esté
presente en el visualizador. Se almacena la medida como valor de referencia y la
lectura pasa a cero. Después se resta este valor de referencia de las medidas
subsiguientes, presentándose la diferencia en el visualizador. Valores majores que la
referencia son positivos y negativos en caso contrario.
F • Mesure Relative
Prenez une mesure et puis activez le Mode Relatif, avec la mesure affichée. La valeur
affichée est enregistrée comme référence et l’affichage est remis à zéro. La valeur
ainsi enregistrée est déduite ensuite des mesures ultérieures et seulement la
différence est affichée. Des valeurs plus grandes que la référence sont positives; des
valeurs plus petites que la référence sont négatives.
RANGE LOCK
Locks the currently displayed range. Each subsequent push of
the button moves to a higher range. From highest range the meter
returns to the lowest range.
D • Bereichssperre
Sperrt den aktiven Bereich. Jeder weiterer Tastendruck wählt einen höheren
Bereich.Auf den höchsten Bereich folgt wieder der niedrigste Bereich. Drücken Sie
RANGE während zwei Sekunden um zur automatischen Bereichswahl
zurückzukehren.
E • Range Lock
Bloquea la escala visualizada en ese momento. Después, cada pulsación de la tecla
hace que se pase a la escala inmediatamente superior. Desde la escala superior se
pasa de nuevo a la inferior. Pulse y mantenga la tecla de rango (RANGE), durante 2
segundos, para volver al auto-rango.
F • Maintien de Gamme
Maintient la gamme active. Chaque nouvelle pression de la touche sélectionne une
gamme plus élevée. De la gamme supérieure l’instrument retourne dans la gamme
inférieure. Pressez la touche RANGE pendant deux secondes pour retourner à la
séléction automatique de gammes.
RANGE
- 24 -
220.Man.08.00 9/11/00 6:05 PM Page 24
PROBE HOLD
TM
Probe Hold keeps the measurement on the display for later
viewing (even after test leads are removed from circuit). Select HOLD
before taking a measurement. The meter beeps to indicate that a
stable measurement has been recorded.
D • Anzeigesperre
Probe Hold erhält die Anzeige für späteres Ablesen (auch wenn die Meßkabel vom
Schaltkreis getrennt sind). HOLD vor der Messung drücken. Ein Biepton meldet die
Erfassung eines stabilen Meßwertes.
E • Probe Hold
Mantiene "congelada" la lectura presente en el visualizador para visualizarla más
adelante (incluso después de desconectar las puntas de prueba del circuito).
Seleccione HOLD antes de hacer una medida. El medidor emite un "bip" para indicar
que ha registrado una medida estable.
F • Maintien de Lecture
Probe Hold maintient l’affichage pour lecture ultérieure (même quand les pointes de
touche sont séparées du circuit). Activez HOLD avant la mesure. Un bip sonore
confirme l’acquisition d’une mesure stable.
AMPERAGE AC/DC SWITCH
The Amperage AC/DC Switch works in conjunction with the Range
Switch’s amperage ranges to select the correct input The LCD will
display the current selection and pressing the switch will alternate the
selection.
D • Gleich-/Wechselstromwahl
Wahlschalter auf gewünschten Strombereich stellen und diese Taste drücken um
Gleich(DC)- oder Wechsel(AC)- Strom zu wählen. DC und AC wird beim Drücken
der Taste alternierend angezeigt.
E • Interruptor de amperaje en AC/DC
Este interruptor trabaja junto a el selector de rangos, a fin de elegir el valor
apropiado de entrada. La pantalla muestra la selección elegida, alternando el rango
cada vez que se pulse.
F • Sélection de Courant CC ou CA
Placez le sélecteur de courant sur la gamme appropriée et pressez ce bouton pour
choisir du courant cc (DC) ou ca (AC). En pressant le bouton de façon répétitive, DC
et AC sont affichés en alternance.
A
HOLD
- 25 -
220.Man.08.00 9/11/00 6:05 PM Page 25
LOGIC MEMORY
The Memory button works only with the Range Switch in the “Logic”
position and enables and disables the display pulse indicator. Use
the MEM feature to wait and indicate a pulse change, 1 to 0 or 0 to 1.
If any pulse is detected the indicator will display and stay on,
even if the pulse is too fast for the UP/DOWN arrow indicators to display.
D • Logikspeicher
Diese Funktion kann nur angewählt werden wenn der Funktionsschalter auf LOGIC
steht, und aktiviert die Impulserfassung. Die Impulsanzeige erscheint (und bleibt
erhalten) bei einem Wechsel des Logikpegels (1 nach 0 oder 0 nach 1), auch wenn
dieser Wechsel zu schnell ist um mit der Dreieck-Anzeige angezeigt zu werden.
E • Grabación de pulso lógico
Este interruptor trabaja solamente con el interruptor de rango en la posición "Logic"
y habilita o deshabilita el indicador de pantalla. Use la característica de memoria
"MEM", cuando se quiere detectar un cambio de estado en el pulso, tanto si es de 0
á 1 o al revés. Si se detecta un pulso, el indicador lo mostrará y permanecerá en ese
estado, incluso si es demasiado rápido para el indicador de flechas "UP/DOWN".
F • Memoire d’Impulsions
Cette fonction peut être activée quand le sélecteur est placé sur LOGIC. Le symbole
indique un changement de niveau logique (1 vers 0 ou 0 vers 1), même si ce
changement est trop rapide pour être indiqué par les triangles.
AUTOMATIC POWER OFF (APO) BUTTON
The Automatic Power Off (APO) button alternates the meter in and out of the
APO mode. When enabled, APO will be displayed in the LCD
and the meter will power off automatically 60 minutes after the last
range switch change or mode button change. Move the Range
Switch to the OFF position and then select a range to power ON the meter from an
APO.
D • Automatische Abschaltung
Wenn diese Taste gedrückt ist (APO in der Anzeige), schaltet das Gerät automatisch
nach ungefähr 60 Minuten Inaktivität ab. Sie können es wieder einschalten durch
drehen des Funktionsschalters nach OFF und zurück nach einer Meßfunktion.
SLEEP
OFF
MEM
- 26 -
220.Man.08.00 9/11/00 6:05 PM Page 26
- 27 -
E • Apagado Automático
La tecla de apagado automático conecta/desconecta de modo alternativo el
medidor. Cuando está conectada se mostrará la palabra "APO" en pantalla y el
medidor se apagará de forma automática después que hayan pasado 60 minutos de
la última medida o pulsación realizada. Actue sobre el interruptor de rango,
poníendolo en la posición "OFF" y seleccione un rango, lo cual provocará que se
active el medidor desde la condición "APO".
F • Coupure Automatique
Quand cette touche est pressée (APO est affiché), l’appareil s’éteint
automatiquement après une heure d’inactivité. Vous pouvez rallumer l’appareil en
tournant le sélecteur vers OFF et puis vers une fonction de mesure.
DISPLAY BACKLIGHT BUTTON
Model 220 has one of the best display backlights available in the
industry. This button turns the backlight on and off. To conserve
battery life, backlight will automatically turn off after approximately 60
seconds.
D • Hintergrundbeleuchtungstaste
Modell 220 hat eine der besten Hintergrundbeleuchtungen auf dem Markt. Diese
Taste schaltet die Hintergrundbeleuchtung ein und aus. Um die Batterie zu schonen,
schaltet die Hintergrundbeleuchtung nach 60 Sekunden automatisch ab.
E • Tecla de iluminación de pantalla
El modelo 220, tiene una de las pantallas con iluminación posterior mejores de la
industria. Este tecla enciende y apaga dicha iluminación. A fin de ahorrar energía, la
iluminación se apaga automaticamente, después de transcurridos 60 segundos.
F • Bouton de rétro-éclairage
Le Modèle 220 dispose d’un des meilleurs rétro-éclairages disponibles sur le
marché. Ce bouton allume et éteint le rétro-éclairage. Afin d’économiser la pile, le
rétro-éclairage s’éteint automatiquement après 60 secondes.
SAFETY TEST LEADS
The test leads included with your meter have shrouded banana plugs to eliminate
the possibility of shock if the plugs accidentally pull out of the meter while
making a measurement. The test leads also have insulated probe tips to avoid
causing shorts when making measurements in dense component areas.
Replacement part number for safety test leads is TL245.
220.Man.08.00 9/11/00 6:05 PM Page 27
D • Sicherheitsmeßkabel
Die Meßkabel haben versenkte Bananenstecker um elektrische Schläge zu
vermeiden. Die Meßspitzen sind zum Teil isoliert, um Kurzschlüsse in dichten
Schaltungen zu vermeiden. Diese Isolation kann entfernt werden. Ersatzteilnummer
ist TL245.
E •Puntas de Prueba de Seguridad
Las puntas de prueba suministradas con el multímetro incluyen unos conectores de
banana protegidos para eliminar la posibilidad de descargas eléctricas. Las puntas
están parcialmente aisladas para evitar cortocircuitos en áreas con alta densidad de
componentes. El usuario puede quitar dicho aislante si lo desea. (Ref: TL245).
F • Cordons de Sécurité
Les fiches banane des cordons sont munies de protecteurs fixes afin de supprimer
les risques de chocs électriques. Les pointes métalliques sont partiellement isolées
pour éviter des court-circuits dans des circuits denses. Cette isolation peut être
enlevée. Numéro de commande: TL245.
- 28 -
OTHER TEST LEADS AND ACCESSORIES
DL243C Standard Meßkabelsatz
DL248C Deluxe Meßkabelsatz
TC 253A Temperatur/Spannungsumsetzer
TL245 Ersatzsicherheitsmeßkabel (900°C/1652°F)
CT231A 150A AC Stromzange
CT232A 1000A AC Stromzange
CT234A 400A AC Stromzange
CT235 1000A AC/DC Stromzange
CT236A 500A AC Stromzange (mV Ausgang)
CT237 200A AC/DC Stromzange
CT238 20A AC/DC Stromzange
RF241 650MHz RF Meßkopf
TC 253A Temperatur/Spannungsumsetzer
(900°C/1652°F)
VC221A Gepolsterte Vinyl-Tragetasche
(fürMeter und Holster)
DL243C Standard Test Lead Set
DL248C Deluxe Test Lead Set
TL245 Standard Replacement Test Leads
TL35A Test Leads with Alligator Clips
CT231A 150A AC Current Clamp
CT232A 1000A AC Current Clamp
CT234A 400A AC Current Clamp
CT235 1000A AC/DC Clamp
CT236A 500A AC Clamp (mV output)
CT237 200A AC/DC Current Clamp
CT238 20A AC/DC Current Clamp
RF241 650MHz RF Probe
TC253A Temperature Converter (900°C/1652°F)
VC221A Padded Vinyl Case. Fits meter & holster.
D • Sicherheitsmeßkabel
DL243C Juego de puntas de prueba
DL248C Juego de puntas de prueba
TL245 Puntas de prueba de seguridad
CT231A Pinza de corriente 150 A CA
CT232A Pinza de corriente 1000 A CA
CT234A Pinza de corriente 400 A CA Admite
elmedidor sin funda
CT235 Pinza de corriente 1000 A CA/CC
CT236A Pinza de corriente 500 A CA Admite el
medidor con funda (salida mV)
CT237 Pinza de corriente 200 A CA/CC
CT238 Pinza de corriente 20 A CA/CC
RF241 Sonda de RF 650 MHz (calidad especial)
TC253A Convertidor de temperatura
(900ºC/1652ºF) de repuesto
VC221A Estuche de vinilo acolchado
E • Accesorios opcionales
220.Man.08.00 9/11/00 6:05 PM Page 28
- 32 -
ESPECIFICACIONES
Genauigkeit, 430µA-430mA
Bereiche±(0.8%vMW +2Dgt)
10A Ber. ±(2.0%vMW +3Dgt)
Spannungsabfall,
430µA-43mA Ber.: 500mVDC;
430mA Ber.: 1.0V DC;
10A Ber.:500mV DC
Überlastschutz: mA Eingang: 0.5A/500V
Sicherung (6.35x32mm); 10kA
Trennver-mögen;10A Eingang:
15A/600VSicherung;100kA
Trennvermögen(10x38mm, UL gelistet).
Wechselstrom (45Hz-1kHz)
Bereiche: 430µA, 43mA, 430mA, 10A
Auflösung, 430µA Bereich: 100nA
Genauigkeit: 430µA-
430mA: ±(1.2%vMW +4Dgt)
10A input ±(2.5%vMW +4Dgt)
Spannungsabfall, 430µA, 43mA Ber.: 500mV
eff.; 430mA Ber.: 1.0V eff.; 10A Ber.:
500mV eff.
AC Umsetzung: MitteWwertbildend, RMS
Anzeige (Sinuswellenform)
Überlastschutz: siehe Gleichstrom.
Widerstand
Bereiche: 430, 4.3k, 43k, 430k,4.3M, 43MW
Auflösung, 430 Bereich: 100m
Genauigkeit, 430 Ber. ±(0.8%vMW +4Dgt),
4.3-430k Ber. ±(0.7%vMW +2Dgt),
4.3M Ber. ±(1.0%vMW +4Dgt),
43M Ber. ±(2.0%vMW +4Dgt)
Max Leerlaufspannung: 3.0V DC im 430
Bereich; 0.6V in allen anderen Bereichen.
Überlastschutz, alle Ber.: 500VDC oder AC eff
Dioden-/Durchgangstest
Bereich: 4.3V
Auflösung: 1mV
Genauigkeit: ±(1.5%vMW +2Dgt)
Kurzschlußstrom: 1.0mA
Max. Leerlaufspannung: 3.2VDC
Ansprechzeit: <500ms.
Ansprechschwelle: 50±25
Überlastschutz: 500VDC oder AC eff
Logik Test
Logikart: TTL 5VDC
Schwelle: Logik 1 (Hoch): 2.8V, Logik 0.8V,
Logik 0 (Niedrig): 0.80±5V
Frequenzbereich: 20MHz
Impulsbreite: 25nsec minimum
Taktverhältnis: >20% und <80%
Anstiegszeit: 10µsec
Ahzeige: 40ms Ton bei Logik 0(OL)
Wiederholrate: 1M PPS
Überlastschutz: 500V DC oder AC eff
Gefährliche Spannungsanzeige
Schwelle: >30V eff oder >60V DC
Especificaciones generales
Visualizador: LCD de 3-3/4 dígitos, 4300
cuentas, indicadores de función, de
unidades y de menu
Indicación de polaridad: Automática
Indicación de sobrecarga: "I.OL"
Indicación de "pila baja": <50 horas, no
se garantiza la precisión en las mediciones
realizadas.
Frecuencia de refresco de la lectura: 2 veces/
segundo, nominal
Temp. de funcionamiento. ( 0 a 80% H.R., sin
condensación): 0 a 50 ºC,
Temp. de almacenamiento: -20 a 40 ºC, 0 a
80% H.R. sin condensación, sin pila.
Coefic. de temper.: 0.1 x (especif. de preci
sión) por ºC ( 0°C a 18°C o 28°C a 50°C)
Fusibles: 0.5A/500V; N.d.I. 10kA15A/600V;
N.d.I. 100kA
Alimentación: Pila normal de 9 V, NEDA
1604, JIS 006P, IEC 6F22
Apagado automático: El medidor se apaga
después de 30 minutos sin actividad o
cuando la pantalla está en "APD". No
enmodo Min/Max.
Duración de la pila (típ.): alcalina, 300 horas
El uso de la iluminación de panel, produce
un consumo extra de potencia, lo cual,
hace que decrezca significamente la vida
de la misma. Tiene un auto apagado a los
220.Man.08.00 9/11/00 6:05 PM Page 32
- 33 -
60 seg.
Dimensiones, sin funda (AlxAnxPr): 183 x 84
x 47 mm
Peso (pila incluida): 484 g
Accesorios: Puntas de prueba, fusible de
repuesto* (0.5A/500V), pila* y Manual de
Instrucciones * en el instrumento
Material de la carcasa: Termoplástico de
inflamabilidad retardada, gran resistencia a
impactos.
Seguridad: Según normas EN61010-1 Cat II
- 1000V; Cat III - 600V EMC: Según
EN55011 y EN61000-4-2
Este producto cumple los requisitos
de las siguientes Directivas de la
Comunidad Europea: 86/336/EEC
(Compatibilidad Electromagnética) y
73/23/EEC (Baja Tensión), con en-
miendas según 93/68/EEC (Marcado CE).
No obstante, la presencia de ruido eléctrico
o campos electromagnéticos intensos en
las proximidades del equipo pueden
introducir perturbaciones en los circuitos
de medida. Los instrumentos de medida
también responden a las señales no
deseadas que puedan estar presentes en
los circuitos de medida. El usuario deberá
tomar las precauciones necesarias para
evitar obtener resultados incorrectos
cuando realiza medidas en presencia de
interferencias electromagnéticas.
Especificaciones eléctricas
Valores de precisión a 23 ºC ±5 ºC,
H.R.<80% sin condensación), garantizados
per un ano
Tensión CC
Escalas: 430mV, 4.3, 43, 430, 1000V
Resolución, escala 430mVV: 0.1 mV
Precisión, todas escalas: ±(0.25%lect +2dgt)
Impedancia de entrada: 10 M
Rech. modo común (hasta 1000VCC: >120 dB)
Rechazo modo normal (50-60 Hz): >60 dB
Protección sobrecarga: 1000 VCC o CA pico;
protección contra transitorios: 6 KV.
Tensión CA
Escalas: 430mV, 4.3, 43, 430, 750V
Precisión:
esc. 430mV @ 45-100Hz ±(1.5%lect +4dgt)
esc. 4.3-430V @ 45-500Hz ±(1.0%lect +4dgt),
esc. 750V @ 45-60Hz ±(1.0%lect +4dgt)
esc. 4.3-43V @ 500Hz-5kHz ±(2.0% lect +5dgt),
esc. 430V @ 500Hz-2kHz ±(2.0% lect +5dgt)
esc 750V @ 60-500Hz ±(2.0% lect+5dgt).
Resolución, escala 430mV: 100µV
Impedancia de entrada: 10 M// <100pF
Tipo de conversión: Valores medios / pantalla
en modo RMS.
Protección sobrecarga, 1000Vcc/750Vrms;
Corriente CC
Escala 430µA, 43mA, 430mA, 10A
Resolución, escala 430µA: 100nA
Precisión, esc. 430µA-430mA:
±(0.8% lect +2dgt)
esc. 10A: ±(2.0% lect +3dgt)
Carga de tensión, esc. 430µA-43mA:
500mVDC; esc. 430mA: 1.0VDC;
esc. 10A: 500mVDC
Protección sobrecarga: entrada mA: fusible
0.5A/500V; Nivel de interrupción:10kA.
Entrada 10A: fusible ceramico rapido
15A/600V; Nivel de interrupción: 100kA;
dimensiones: 10x38mm, listado UL
Corriente CA (45Hz-1kHz)
Escalas: 430µA, 43mA, 430mA, 10A
Resolución, escala 430µA: 100nA
Precisión,
escalas 430µA-430mA: ±(1.2%lect+4dgt)
escala 10A: ±(2.5%lect +4dgt)
Carga de tensión, escalas 430µA, 43mA:
500mVrms, esc. 430mA: 1.0Vrms; esc.
10A: 500mVrms
Tipo de conversión: Valores medios / pantalla
en modo RMS.
Factor de cresta: 1:1 hasta 5:1
Protección sobrecarga: vea corriente CC.
Resistencia
Escalas: 430, 4.3k, 43k, 430k,4.3M, 43M
Resolución, escala 430: 100m
Precisión, esc.430: ±(0.8%lect +4dgts),
220.Man.08.00 9/11/00 6:05 PM Page 33
- 34 -
SPECIFICATIONS
esc. 4.3-430k: ±(0.7%lect +2dgts),
esc 4.3M: ±(1.0%lect +4dgts),
esc 43M: ±(2.0%lect +4dgts)
Prot. sobrec., todas esc.: 500 V CC o CA ef.
Tensión de circuito abierto: escala 430: 3.0
VCC tipico; otras escalas: 0.6 VCC tipico.
Prueba de diodos, Continuidad
Escalas: 4.3V Resolución: 1mV
Precisión: ±(1.5%lect +2dgt)
Corriente de cortocircuito: 1.0mA
Tensión de circuito abierto: 3.2Vcc
Tiempo de respuesta: <500ms
Indicación audible, continuidad: 50±25
Protección sobrecarga.: 500V CC o CA ef.
Test Lógico
Tipo de lógica: TTL 5.0 VDC
Niveles de disparo: 1 (alto): 2,8V±0,8V.
0 (bajo): 0,8V±0,5V
Ancho de respuesta: 20 Mhz.
Ancho de pulsos: 25 nseg. mínimo.
Ciclo de trabajo: >20% y <80%
Tiempo de ataque del pulso: 10 microseg.
Ritmo de repetición: 1 M PPS
Indicación:”Bip” de 40ms lógico 0 (bajo)
Protección por sobre- carga: 500 VDC ó AC
efectivos.
Indicacion tensión peligrosa
Niveles: Mayor de 30VRMS y 60 VDC. F
specifications
Spécifications Générales
Afficheur: LCD 3-3/4 digits, 4300 points,
indication d’unités et de fonctions.
Indication de Polarité: Automatique
Indication de Dépassem. de Calibre: "I.OL"
Indication de pile déchargée: . Restent 50
heures. La précision n’est plus garantie
Taux de mesure: 2/sec, nominal.
Température de fonctionn.: (0 à 80% H.R.
sans condensation): 0°C à +50°C
Température de Stockage: -20°C à 40°C, 0 à
80% HR, sans condens., pile enlevée
Coefficient de température: <0.1 x (préc.
spécif.) par °C (0°à 18°C et 28°à 50°C)
Fusibles: 0.5A/500V - pouv. coup.10kA
15A/600V - pouv. coup. 100kA
Alimentation: Pile 9-volt standard, NEDA
1604, JIS 006P, IEC 6F22
Coupure automatique: après 30 minutes
d’inactivité et APD affiché. Pas en fonction
Min/Max.
Autonomie, alcalin (typiq.): 300 heures. Le
rétroéclairage consomme beaucoup de
courant est diminue sensiblement la durée
de vie de la pile. Coupure automatique
après une minute.
Dimensions, sans gaine (HxLxP): 183 x 84 x
47 mm
Poids (avec pile): 484 gr
Accessoires: une paire de cordons de mesure,
un fusible de réserve (0.5A/500V)*, une
pile*, et ce manuel. ( * installé)
Matériau de boîtier: thermoplastique résistant
au feu et aux chocs. Sécurité: Conforme à
EN61010-1 Cat II - 1000V; Cat III - 600V.
EMC: selon EN55011 et EN61000-4-2.
Ce produit est conforme aux
exigences des directives suivantes
de la Communauté Européenne:
89/336/EEC (Compatibilité
Electromagnétique) et 73/23/EEC (Basse
Tension), modifiée par 93/68/EEC (CE
Marking). Cependant, du bruit électrique
ou des champs électromagnétiques
intenses dans la proximité de l’instrument
peuvent influencer le circuit de mesure.
L’instrument peut égale-ment être perturbé
par des signaux parasytes dans le circuit
mesuré. L’utilisateur doit être vigilant et
prendre des précautions appropriées pour
éviter des résultats erronés quand les
mesures sont prises en présence
d’interférences électromagnétiques.
220.Man.08.00 9/11/00 6:05 PM Page 34
- 36 -
OWNER/DISTRIBUTOR LEVEL MAINTENANCE
If there appears to be a malfunction during the operation of the meter, the
following steps should be performed in order to isolate the cause of the problem:
Check the battery. Review the operating instructions for possible mistakes
in operating procedure. Inspect and test the Test Probes for a broken or
intermittent connection. Inspect and test the fuse. See Fuse Replacement.
Except for the replacement of the battery or fuse, repair of the multimeter should
be performed only by a Factory Authorized Service Center or by other qualified
instrument service personnel.
The front panel and case can be cleaned with a mild solution of detergent and
water. Apply sparingly with a soft cloth and allow to dry completely before using.
Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
D• Wartung & Reparatur
Prüfen Sie zuerst folgende Fehlerquellen: Meßkabel (Brüche), Anschluß, Zustand
von Batterie und Sicherung, richtiger Meßvorgang, Eingangs- und
Bereichsgrenzen, usw. Mit Ausnahme des Batterie- und Sicherungswechsels soll
jede Reparatur nur durch eine durch Wavetek anerkannte Servicestelle durchgeführt
werden. Das Gerät kann mit einer milden Seifenlösung gereinigt werden. Sparsam
auftragen und vor Gebrauch gut trocknen lassen.
E •Maintenimiento y Reparación
Para identificar la causa del problema: Compruebe la pila; revise las instrucciones
de uso; inspeccione las puntas de prueba por si hay una conexión rota o
intermitente; inspeccione la pila y el fusible. Excepto la sustitución de la pila o el
fusible, cualquier trabajo de reparación del multímetro debe hacerse
exclusivamente por personal técnico cualificado para este tipo de reparaciones.
Para limpiar la carcasa puede utilizarse una solución suave de agua y detergente.
Aplique con un paño suave y deje secar antes de usar el medidor.
F • Maintenance & Réparation
Avant d’expédier votre multimètre pour réparation, vérifiez les cordons de mesure
(rupture), pile et fusible, connections, procédure de mesure, limites d’entrée et de
calibres, etc. Excepté pour le remplacement de la pile et du fusible, toute réparation
doit être effectuée uniquement par un Centre de Services agrée par Wavetek. Vous
pouvez nettoyer le boîtier avec un détergent doux. Appliquez parcimonieu- sement
et laissez sécher complètement avant utilisation.
220.Man.08.00 9/11/00 6:05 PM Page 36
Ref. KTK-15 oder Wavetek Meterman Ref 3000-400-214.
• 430mA Eingang: 0.5A/500V Sicherung (klein) – Wavetek
Meterman Ref. FP385.
(Eine Ersatzsicherung ist im Gerät enthalten. Beim Ersetzen der Ersatzsicherung
sicherstellen daß diese gut im Sicherungshalter sitzt. Käme sie los, dann könnte sie
einen Kurzschluß verursachen.) Gerät wieder zusammensetzen. Schrauben nicht zu
fest anziehen um das Gewinde des Gehäuses nicht zu beschädigen.
E • Sustitución de la pila y los fusibles
Advertencia: Para evitar el peligro de descarga eléctrica, apague el medidor y
desconecte las puntas de prueba antes de abrir la tapa posterior.
Advertencia: Utilice solamente fusibles equivalentes a los especificados. Ponga el
medidor boca abajo sobre una superficie limpia. Separe las dos mitades de la
carcasa (anterior y posterior) aflojando los 3 tornillos que las mantienen unidas.
Asegúrese de que o entre suciedad o grasa al medidor. No toque ningún
componente de la placa. Sustitución de la pila: extraiga la pila alcalina de 9 V (NEDA
tipo 1604, JIS006P o IEC 6F22) y cámbiela por otra equivalente.
Sustitución de los fusibles: Cambie los fusibles que hayan saltado por otros
equivalentes:
• Entrada 10 A: fusible largo 15A/600V – Little fuse ref. KLK-15, Bussman ref. KTK-
15 o Wavetek
Meterman ref. 3000-400-214.
• Entrada 430 mA: fusible corto 0.5A/500V - Wavetek
Meterman ref. FP385. (Hay
un fusible de repuesto en el interior de la carcasa. Al cambiar este fusible, asegúrese
de insertarlo firmemente en el portafusibles para evitar que se salga y cause un
cortocircuito). Vuelva a cerrar el instrumento.
Advertencia: Si no apaga el multímetro antes de cambiar la pila, podría causar
daños al instrumento y a la pila
F • Remplacement Pile et Fusible
Avertissement: Pour éviter des chocs électriques, éteignez l’appareil et retirez les
cordons de test avant d’ouvrir le boîtier.
Avertissement: L’utilisation d’un fusible incorrect peut entraîner des blessures
graves. Déposez l’appareil, face avant vers le bas sur une surface propre et
capitonnée. Dévissez et enlevez le boîtier arrière. Assurez-vous que ni poussière, ni
huile ni autre contaminant n’entrent dans l’appareil. Ne touchez pas le circuit
electrique.
Remplacement de la pile: Soulevez la pile du boîtier arrière et enlever la manche
de protection. Déconnectez la pile. Appliquez la manche de protection sur une
nouvelle pile, type NEDA 1604, JIS 006P ou IEC 6F22, et installez-la en observant la
polarité.
- 38 -
220.Man.08.00 9/11/00 6:05 PM Page 38
D • Reparatur
Lesen Sie die Gewährl ei stung bevor Sie eine Reparat ur unter oder außerhalb
Gewährleistung anfragen. Unter Gewährleistung bringen Sie bitte das def ekte Gerät
zu ei ner aner kannten Wavetek Meterman Verkaufsstelle oder Servicestelle füreinen
direkten Umtausch. Außerhalb Gewährlei st ung senden Sie das Gerät zu einer
Wavetek Meterman anerkannten Servicestelle. Bitte informieren Sie sich bei Wavetek
Meterman oder ihrem Fachhändler nach der dichtst beigelegen Adresse und nach
aktuellen Reparaturgebühren. Bitte senden Sie folgende Informationen und
Dokumente mit: Firmenname, Kundenname, Adresse, Telefoonnummer,
Kaufnachweis (für Reparaturen unter Gewährl eistung), ei ne kurz e Beschr eibung
der gewünschten Handlung, und di e gefordert e Bezahl ung ( Eingr iffe außerhal b
der Gewährleistung). Bitte auch Testkabel beifügen. Bezahlungen in Form eines
Checks, Bezahlungsformulieren, Kredietkarte mit Verf alldatum, usw. bitte in Namen
der Servicestelle aufstellen. Bitte Multimeter (Frei) senden an:
in U.S.A. in Canada in Europa
Wavetek Meterman Wavetek Meterman Wavetek Meterman
1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way
Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K.
Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824
Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409
oder an die Ihnen mitgetei lte Adresse. Multimeter wird (Frei) zurück geschickt.
E • Reparación
Lea las condiciones de garantía, al principio de este manual, antes de solicitar
cualquier reparación dentro o fuera de garantía. Si la reparación es en garantía,
puede llevar el multímetro defectuoso a cualquier Distribuidor Autorizado o Centro
de Servicio de Wavetek Meterman, donde le cambiarán en mano el producto por otro
igual o similar. Para reparaciones fuera de garantía deberá enviar el multímetro a un
Centro de Servicio de Wavetek Meterman. En Wavetek Meterman, o en su
Distribuidor o punto de venta, le indicarán el Centro de Servicio más próximo y las
tarifas de reparación vigentes. La documentación que acompañe a todo multímetro
enviado para reparación debe incluir los siguientes datos: nombre de la empresa,
persona de contacto, dirección, número de teléfono, prueba de compra (para
reparaciones en garantía), una breve descripción del problema o el servicio
requerido y, en caso de reparaciones fuera de garantía, si desea presupuesto previo.
- 40 -
220.Man.08.00 9/11/00 6:05 PM Page 40
Por favor envíe las puntas de prueba con el multímetro. El importe de la reparación
se enviará en forma de cheque, tarjeta de crédito con fecha de expiración u orden de
pago a favor de Wavetek Meterman o del Centro de Servicio específico. El
multímetro se enviará a portes pagados a una de las siguientes direcciones, o al
Centro de Servicio que le hayan indicado:
en EE.UU. en Canadá en Europa
Wavetek Meterman Wavetek Meterman Wavetek Meterman
1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way
Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K.
Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824
Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409
Wavetek Meterman devolverá el multimetro reparado a portes pagados.
F • Réparation
Lisez la garantie au début de ce manuel avant de demander une réparation sous
garantie ou hors gar antie. Pour une réparation sous garantie , adressez-vous à votre
revendeur Wavetek Meterman ou à un centre de services agréé par Wavetek
Meterman pour un échange direct. Pour une réparation hors garantie, envoyez votre
multimètre à un Centre de Services agrée par Wavetek Meterman . Téléphonez à
Wavetek Meterman ou demandez à votre revendeur pour l’adresse la plus proche.
Pour les réparations hors garantie, demandez dabord les tarifs. Joignez les
informations et documents suivants: nom de sociètè, nom du client, adresse,
numéro de téléphone, preuve d’achat (pour réparations sous garantie), une brève
description de l’intervention souhaitée et le payement (pour réparations hors
garantie). Ajoutez également les cordons de test. Le payement, sous forme de
chèque, virement, carte de crédit avec date d’expiration, etc. doit êtr e éta bli au nom
du Centre de Servic es. Le multimètre doit être envoyé port payé à:
en U.S.A. en Canada en Europe
Wavetek Meterman Wavetek Meterman Wavetek Meterman
1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way
Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K.
Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824
Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409
ou à l’adresse communiquée. Le multimètre vous sera renvoyé port payé.
- 41 -
220.Man.08.00 9/11/00 6:05 PM Page 41

Transcripción de documentos

220.Man.08.00 9/11/00 6:05 PM Page 3 WARRANTY The 220 Digital Multimeter is warranted against any defects of material or workmanship within a period of one (1) year following the date of purchase of the multimeter by the original purchaser or original user. Any multimeter claimed to be defective during the warranty period should be returned with proof of purchase to an authorized Wavetek Meterman Service Center or to the local Wavetek Meterman dealer or distributor where your multimeter was purchased. See maintenance section for details. Any implied warranties arising out of the sale of a Wavetek Meterman multimeter, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to the above stated one (1) year period. Wavetek Meterman shall not be liable for loss of use of the multimeter or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss. Some states do not allow limitations on how long implied warranties last or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. D GEWÄHRLEISTUNG Die Digitale Multimeter Modelle 220 ist ab Kaufdatum für ein (1) Jahr gegen Material- und Herstellungsfehler gewährleistet. Siehe Kapitel "Unterhalt und Reparatur" für Einzelheiten. Implizierte Schadeforderungen sind auch auf ein Jahr beschränkt. Wavetek Meterman ist nicht ansprechbar für Gebrauchsverluß oder Folgeschäden, Ausgaben, Gewinnverluß, usw. E GARANTIA Este Multímetro Digitale Modelo 220 está garantizado contra cualquier defecto de material o de mano de obra durante un periodo de un (1) año contado a partir de la fecha de adquisición. En la sección de "Mantenimiento y Reparación" se explican los detalles relativos a reparaciones en garantía. Cualquier otra garantía implícita está también limitada al periodo citado de un (1) año. Wavetek Meterman no se hará responsable de pérdidas de uso del multí metro, ni de ningún otro daño accidental o consecuencial, gastos o pérdidas económicas, en ninguna reclamación a que pudiera haber lugar por dichos daños, gastos o pérdidas económicas. F GARANTIE Le multimètre digitaux, Modèle 220 est garanti pour un (1) an à partir de la date d’achat contre les défauts de matériaux et de fabrication. Voir chapitre "Maintenance et Réparation" pour plus de détails. Toute garantie impliquée est également limitée à un an. Wavetek Meterman ne peut être tenu responsable pour perte d’utilisation ou autres préjudices indirects, frais, perte de bénéfice, etc. 220.Man.08.00 9/11/00 6:05 PM Page 1 CONTENTS Introduction ........................................................ 2 Safety Information ............................................... 3 Instrument Familiarization ................................... 5 Measurement Procedures ................................. 10 Menu Functions ................................................ 21 Test Leads and Accessories ............................... 28 Specifications ....................................................29 Maintenance and Repair ................................... 36 D • Inhalt Einleitung .............................................................2 Sicherheitsinformationen ......................................4 Vorstellung des Gerätes. ......................................5 Meßprozeduren ................................................. 11 Menü-Funktionen .............. ............................... 21 Meßkabel und Zubehör......... ............................. 28 Spezifikationen ....................... .......................... 31 Wartung und Reparatur ........... .......................... 36 E • Contenidos Introducción ........................ ............................... 2 Información de seguridad ...... ............................. 4 Familiarización con el instrumento.... ...................5 Procedimientos de medida ....... ........................ 11 Funciones de menú ................. ......................... 21 Puntas de prueba y accesorios . ........................ 28 Especificaciones ...................... ..........................32 Mantenimiento y reparación ..... ........................ 36 F • Contenu Introduction........................... ...............................3 Informations de Sécurité ........ ............................. 5 Présentation de l’Appareil ......... .......................... 5 Procédures de Mesure ............... ....................... 11 Fonctions de Menu....................... ......................21 Câbles de Mesure et Accessoires ... .................. 29 Spécifications .............................. ..................... 33 Maintenance et Réparation ................................ 36 SYMBOL DEFINITIONS D • Erklärung der Symbole = E • Significado de los símbolos = F • Explication des Symboles Direct current •D• Gleichstrom •E• Corriente continua •F• Courant continu. Alternating current •D• Wechselstrom •E• Corriente alterna •F• Courant alternatif. Ground connection •D• Erdanschluß •E• Conexión a tierra •F• Connection de terre. Attention! Refer to Operating Instructions •D• Achtung! Bitte Anleitung lesen •E• ¡Atención! Consulte las Instrucciones de Uso •F• Attention! Consultez le manuel. Dangerous voltage may be present at terminals •D• Eine gefährliche Spannung kann an den Eingängen anliegen •E• Puede haber tensión peligrosa en los terminales •F• Une tension dangereuse peut être présente aux entrées. Low battery symbol •D• Entladene Batterieanzeige •E• Símbolo de pila baja •F• Symbole de pile déchargée. This instrument has double insulation •D• Dieses Gerät ist doppelt geisoliert •E• Este instrumento tiene doble aislamiento •F• Cet appareil est prévu d’une double isolation. Logic Test HIGH and LOW indicators •D• Logik Test HIGH und LOW Indikatoren •E• Indicadores lógicos de prueba Alto (High) y Bajo (Low). •F• Indicateurs de test logique HIGH et LOW. Audio Alarm Indicator •D• Auditive Alarmanzeige •E• Indicador audible de alarma •F• Indicateur d’alarme auditif. Logic Pulse •D• Logikpuls •E• Pulso lógico •F• Impulsion logique. -1- 220.Man.08.00 9/11/00 6:05 PM Page 2 INTRODUCTION The digital multimeter 220 is a 3-3/4 digit, autoranging, AC-coupled, average measuring & RMS reading instrument that measures voltage, current, resistance, continuity, diode junctions, TTL and logic. Menu selection allows Range Lock, Probe HoldTM, Relative Measurement, Auto Min Max Avg Measurement and backlight on/off. The instrument is completely sealed. D • Einleitung Das Modell 220 ist ein 3-3/4-stelliges AC-gekoppeltes, mittelwert- messendes Digitalmultimeter mit automatischer Bereichswahl. Es mißt Spannung, Strom, Widerstand und Durchgang und führt Diodentest, TTL- und Logiktest aus. Eine Menüwahl umfaßt Bereichssperre, Meßwertspeicher, Relativmessung, Auto Min Max Avg und Anzeigen-Hintergrundbeleuchtung. Das Gerät ist vollständig abgedichtet. E • Introducción El multímetro digital 220 es un instrumento de medidade 3-3/4 dígitos, trabajando en alterna, con autorango, indicando las lecturas en valor medio y RMS, pudiendo medir voltajes, corriente, resistencia, continuidad, diodos, uniones y lógica de tipo TTL. El selector de menús permite el bloqueo de rango, retención del valor medido, medición relativa, medición media, auto, mínima, máxima y apagado automático de la iluminación de pantalla. El instrumento está completamente sellado. D • Introduction Le modèle 220 de est un multimètre numérique 3-3/4 digits à sélection automatique des gammes, mesurant la valeur moyenne avec couplage CA. Il mesure la tension, le courant, la résistance et la continuité, et effectue des tests de diodes et de logique. Un menu de fonctions comprend le bloquage de gamme, le maintien de lecture, la mesure relative, Auto Min Max Avg et un rétro-éclairage de l’afficheur. L’instrument est complètement étanche. WARNINGS AND PRECAUTIONS ■ This instrument is EN61010-1 certified for Installation Class II, 1000V and Class III, 600V. It is recommended for use in distribution level and fixed installations, as well as lesser installations, and not for primary supply lines, overhead lines and cable systems. ■ All inputs are protected against continuous overload conditions up to the limits of each function's stated input protection (see specifications). Never exceed these limits nor the ratings marked on the -2- 220.Man.08.00 9/11/00 6:05 PM Page 4 isolieren ! Das Gerät nicht mit der Trageschlaufe am eigenen Körper befestigen. ■ Bei Strommessung, Multimeter immer in Serie schalten – Nie in parallel mit Spannungsquelle. ■Sicherung immer mit gleichwertiger ersetzen. ■Gerät nicht in explosiver Umgebung verwenden. E • Advertencias y Precauciones ■Este instrumento está homologado según EN61010-1/CE para la Categoría de Instalación II - 1000V o Categoría de Instalación III - 600V. Su uso está recomendado en el nivel de distribución y en instalaciones fijas, así como en instalaciones menores, pero no en líneas principales de suministro, líneas aéreas ni sistemas de cable. ■No supere nunca los límites de entrada para las diferentes funciones (vea Especificaciones), ni los límites marcados en el instrumento. ■Para medidas de tensión, el circuito sometido a prueba debe estar protegido con un fusible de 20 A o un disyuntor. ■Tenga especial cuidado al: medir tensión >20 V // corriente >10 mA // tensión de red de CA con cargas inductivas // tensión de red de CA durante tormentas eléctricas // corriente, si salta el fusible en un circuito con tensión de circuito abierto >600 V (500 V en la entrada de mA) // trabajar con pantallas TRC nInspeccione siempre el multímetro, las puntas de prueba, los conectores y los accesorios antes de cada uso. No utilice ningún componente que esté dañado. ■No se ponga Ud. a tierra cuando esté tomando medidas, y no toque nunca partes expuestas de los circuitos. No utilice la cinta "Flex-Strap" para sujetar el multímetro a su cuerpo. ■Al medir corriente, conecte siempre el multímetro EN SERIE con la carga - NUNCA EN PARALELO con una fuente de tensión. ■Nunca sustituya un fusible con otro que no tenga las mismas especificaciones. ■No utilice el instrumento en ambientes potencialmente explosivos. F • Avertissements et Précautions ■ Cet instrument est certifié EN61010-1/CE catégorie d’installation II, 1000 ou catégorie III, 600V. Son utilisation est recommandée pour le niveau de distribution de réseau, les installations fixes et systèmes subordonnés, et non pour les installations de puissance et lignes de transmission et câblages à haute tension. ■ N’excédez jamais les limites de surcharge continues (voir spécifications) ou d’autres limites marquées sur l’appareil. nPour les mesures de tension, le circuit sous mesure doit être protégé par un fusible 20A ou par un disjoncteur. ■Soyez très prudent quand vous mesurez des tensions >20V ou des courants >10mA // tension ou courant de secteur avec charge inductive ou par temps de tempête // du courant quand le fusible saute dans un circuit avec tension en circuit ouvert de >600 volts (>500V pour l’entrée mA) // dans des appareils à tube cathodique (transitoires à haute tension) nInspectez appareil, câbles, connecteurs avant chaque mesure. -4- 220.Man.08.00 9/11/00 6:05 PM Page 5 N’utilisez pas des pièces endommagées ■Ne touchez pas les pointes de touche ou le circuit pendant les mesures. Isolez-vous ! N’utilisez pas la boucle de suspension pour attacher l’appareil à votre propre corps. ■Pour la mesure de courant, connectez l’appareil en série avec le circuit – JAMAIS en parallèle avec une source de tension. ■Remplacez les fusibles toujours par des fusibles équivalents ■N’utilisez pas cet appareil dans des atmosphères explosives. PREPARATION FOR USE – UNPACKING Your shipping carton should include the multimeter, a holster, one test lead set (one black, one red), one 9V battery (installed) and this manual. If any of the items are damaged or missing, immediately return the complete package to the place of purchase for an exchange. D • Gebrauchsvorbereitung - Auspacken Die Verpackung sollte enthalten: ein Multimeter, ein Schutzholster, ein Meßkabelsatz (ein schwarz, ein rot), eine 9V Batterie (im Gerät) und diese Anleitung. Wenn ein Teil fehlt oder beschädigt ist, bitte bei der Verkaufstelle umtauschen. E • Preparación del multímetro para su uso - Desembalaje El embalaje debe contener: el multímetro, una funda, un juego de puntas de prueba (una negra y otra roja), una pila de 9 V (instalada), y este manual. Si falta algún componente u observa daños, devuelva el conjunto al lugar donde lo adquirió para que se lo cambien. F • Préparation pour l’Emploi - Déballage Votre emballage doit contenir: un multimètre, une gaine de protection, un jeu de câbles de mesure (un rouge, un noir), une pile 9V (installée) et ce manuel. Si une pièce manque ou est endommagée, retournez à votre point de vente pur un échange. PROTECTIVE HOLSTER The holster/tilt stand protects the meter from accidental falls and provides greater ease of use. Both test lead probes can be attached to the holster for storage. One probe can be attached for measurement, holding the meter with probe in one hand and the second probe in the other hand. D • Schutz-Holster Das Schutzholster schützt das Gerät vor Stürzen und Stößen. Die Meßspitzen können am Holster befestigt werden. -5- 220.Man.08.00 9/11/00 6:05 PM Page 6 3-3/4 digit LCD with unit indicators Menu Functions, see page 21 Menübalken – siehe “Menüfunktionen”, Seite 21 Barra de menú - ver “Funciones de menú”, página 21 Barre de menu - voir “Fonctions de Menu”, page 21 3-3/4 Digit LCD mit Einheitsanzeigen LCD de 3-3/4 dígitos; indicadores de unidades LCD 3-3/4 digits; indicateurs d’unités Low Battery, (p. 8) Batterie entladen (S. 8) Pila baja (p. 8) Pile déchargée (p. 8) LOGIC MEM REC MAX MIN A AVG VG HOLD RANGE DC AC mV muA Mk APO 220 MIN MAX Function/Range Selector, Funktions-/BereichSchalter Selector de Función/Escala Sélecteur fonctions/ calibres REL RANGE MEM A HOLD LOGIC 430uA 43 mA 430 mA V V 10A High input for voltage and resistance (p. 12) V-Ω Eingang. Hoch für Spannung und Widerstand (S. 12) COM mA V Entrada “alta” para tensión y resistencia (p. 12) FUSED MAX 430mA 10A 10A Input (p. 13) 10A Eingang (S. 13) Entrada 10A (p. 14) Entrée 10A (p. 15) Boutons de menu (p. 21) SLEEP OFF OFF 430mA Input (p. 13) 430mA Eingang (S. 13) Entrada 430mA (p. 14) Entrée 430mA (p. 15) Menu Buttons, (p. 21) Menutasten (S. 21) Teclas de menú (p. 21) CAT II1000V CAT III 600V FUSED 10A MAX 1000V 750V MAX Entrée V-Ω. Haut pour tension et résistance (p. 12) COM Input – common or low input for all measurements (p. 12) COM Eingang – Referenzpunkt für alle Messungen (S. 12) COM- entrada común o “baja” para todas las medidas (p. 12) Entrée COM – commun ou bas pour toutes mesures (p. 12) -6- 220.Man.08.00 9/11/00 6:05 PM Page 8 manueller Bereichswahl - RANGE LOCK - Fig. 1): "I.OL" Anzeige. Höheren Bereich wählen oder Messung unterbrechen. Anmerkung: Überlastanzeige (ohne Ton) ist normal bei Widerstands- und Durchgangsmessung wenn Meßkabel-spitzen offen sind oder wenn der Meßwert den Bereich überschreitet. Bei Logikmessung ist die Überlastanzeige (ohne Ton) permanent. Eingangswarnung: (Fig. 2) "FErr" wird angezeigt wenn ein Meßkabel mit dem mA oder 10A Eingang verbunden ist, der Wahlschalter jedoch nicht auf der richtigen Stromfunktion steht. (Würde mit dem Stromeingang Spannung gemessen werden, dann könnte ein sehr hoher Strom im Gerät entstehen). Alle Strombereiche sind mit flinken Sicherungen geschützt. Entladene Batterieanzeige (Fig. 3) : Bei dieser Anzeige sind weniger als 50 Betriebsstunden möglich. Die Geanuigkeit ist nicht länger garantiert. E • Indicación de sobrecarga La sobrecarga de entrada (en la escala superior en caso de selección automática de escala) se indica mediante "I.OL" y un tono continuo. Desconecte las puntas de prueba del circuito de medida, ya que el nivel de entrada es superior a la capacidad del medidor. La sobrecarga del visualizador (la entrada supera la capacidad de la escala seleccionada en modo manual) también se indica mediante "I.OL". Seleccione una escala más ata. Si ya está en la más alta, interrumpa la medida. Nota: La condición de sobrecarga (sin sonido) es normal en los rangos de Ohmios, continuidad y lógica. Aparece cuando las puntas de prueba en las escalas de ohmios y continuidad no están conectadas a ningún componente, o cuando el valor medido, es mayor que el rango de resistencia elegido. Está permanentemente encendida cuando se elige la función lógica. Aviso de Entrada Incorrecta: El visualizador muestra un código de error "FErr" cuando se inserta una punta de prueba en la entrada de mA o 10 A y el selector no está posicionado en el valor correcto de corriente. (Si se conecta el multímetro a una fuente de tensión con las puntas en la entrada de corriente, podría exponer el instrumento a corrientes muy elevadas). Todas las escalas de corriente están protegidas mediante fusibles de acción rápida. Batería baja: Cuando el indicador de batería baja aparece en pantalla, la batería tiene menos de 50 horas de operatividad y la precisión del medidor no puede ser garantizada. -8- 220.Man.08.00 9/11/00 6:05 PM Page 10 D • Akustische Anzeigen Das Gerät gibt einen Einzelton ab bei Funktionswechsel, bei Aktivierung einer "validen" Taste und wenn neue Anzeigenspeicherwerte erfaßt werden. Ein Dauerton wird abgegeben bei Eingangsüberlast, bei Durchgangsmessung, wenn der Widerstand unter 50Ω liegt und beim Messen im 10 Bereich, wenn der Eingangsstrom 10A überschreitet. E • Avisos audibles El medidor emite un solo pitido, cuando se cambia un parámetro, se debe pulsar la tecla "valid" del panel frontal ya que en caso de hacerlo, los valores medidos son actualizados. El medidor emite un tono continuo en caso de sobrecarga de entrada, y midiendo continuidad cuando el valor de la resistencia es <50Ω. Cuando se usa la entrada de 10 A, el medidor emite un tono continuo si la corriente supera los 10 A. F • Indication Sonore L’instrument émet un bip sonore en cas de changement de fonction, quand un bouton valide est pressé ou une nouvelle valeur est enregistrée en Probe Hold. Un signal sonore continu indique un dépassement de la limite d’entrée, une résistance inférieure à 50Ωen mesure de continuité, ou un courant supérieur à 10A en mesure de courant (avec l’entrée 10A). MEASURING PROCEDURES GENERAL: Turn instrument on by turning function/range switch away from OFF and selecting the parameter you want to measure. Ranging: This instrument is autoranging on all Volts and Ohms ranges and manual ranging on Amperes ranges. When in Volts and Ohms ranges, it automatically selects the range that gives the best resolution for the measured value. A range can be locked through menu selection (see Menu Functions, page 24). You can tell which range you are in by the position of the decimal point and the measurement unit displayed. General Measurement Procedures: ■ When connecting or disconnecting test leads to a circuit, always turn off power to device or circuit being tested and discharge all capacitors. ■ Strictly observe the max input limits. ■ Do not change functions while test leads are connected to circuit. D • Meßprozeduren Einschalten: Gerät einschalten durch Funktions-Bereichsschalter weg von OFF nach der gewünschten Funktion drehen. Bereichswahl: Dieses Gerät hat automatische Bereichswahl für Spannungs- und Widerstandsmessung und manuelle Bereichswahl für Strommessung. Bei Spannung und Widerstand wählt das Gerät automatisch den Bereich der die beste Auflösung - 10 - 220.Man.08.00 9/11/00 6:05 PM Page 11 bietet. Ein Bereich kann durch Menüwahl festgehalten werden (siehe Menüfunktionen, Seite 24). Der Dezimalpunkt und die angezeigte Einheit geben an in welchem Bereich Sie sich befinden. Allgemein: ■ Vor Verbinden und Trennen der Meßkabel mit dem Schaltkreis, diesen abschalten und Kondensatoren entladen. ■ Maximale Grenzen nicht überschreiten. ■ Keinen Funktionswechsel vornehmen während die Meßspitzen mit dem Schaltkreis verbunden sind. E • Procedimientos de medida GENERAL: Encienda el instrumento, poniendo el selector de función/escala fuera de OFF y seleccionando el parámetro que desee medir. Escalas: Este instrumento funciona en modo autorango para mediciones de voltaje y ohmios y en modo manual en las mediciones de amperios. Cuando se trabaja en voltios y ohmios, el aparato selecciona de forma automática el rango de mejor resolución para el valor medido. Es posible fijar una escala desde el menú (vea Funciones de menú, pág. 24). La escala en que está en un momento dado puede determinarse por la posición del punto decimal y las unidades de medida. Procedimientos generales: ■ Antes de conectar o desconectar las puntas de prueba a/de un circuito, apague siempre el dispositivo o circuito sometido a prueba y descargue todos los condensadores. ■ Observe estrictamente los límites máximos de entrada. ■ No cambie de función mientras las puntas de prueba estén conectadas a un circuito. F • Procédures de Mesure Mise sous tension: Allumez l’appareil en tournant le sélecteur de fonctions à partir de OFF vers le paramètre à mesurer. Sélection des gammes: La sélection de gammes est automatique pour les mesures de tension et de résistance, et manuelle pour la mesure de courant. En mesure de tension et de résistance, l’appareil choisit automatiquement le gamme qui offre la meilleure résolution. Une gamme peut être bloquée par sélection de menu (voir page 24). Le point décimal et l’unité affichée indiquent la gamme dans laquelle vous mesurez. Général: ■ Avant de connecter ou de déconnecter les cordons de test, coupez l’alimentation du circuit à mesurer et déchargez les condensateurs. ■ Ne dépassez pas les limites d’entrée. ■ Ne changez pas de fonction tandis que les pointes de touche sont connectées au circuit. - 11 - 220.Man.08.00 9/11/00 6:05 PM Page 14 A 3a or A 5 DC A Discharge capacitors Kondensatoren entladen Descargue los condensadores Décharger les condensateurs 3b 220 MIN MAX REL RANGE MEM A HOLD SLEEP OFF LOGIC 430uA 3c 2a V 2 43 mA 430 mA V 10A OFF 4 COM mA 3d V FUSED MAX 430mA 10A CAT II1000V CAT III 600V FUSED 10A MAX 1 Fig. 5 1000V 750V MAX red/rot/ roja/rouge E • Medidas de corriente CC y CA (DCA y ACA) -(vea Fig. 5) ❶Conecte la punta de prueba roja a la entrada de 430mA para medidas de corriente hasta 430 mA, o a la entrada de 10 A para medidas de corriente hasta 10 A. Conecte la punta de prueba negra a la entrada COM. ❷Seleccione el rango de amperios a medirse y pulse la tecla A para seleccionar si la medición es en alterna o contínua. La indicación en el lado izquierdo de la pantalla cambia. ❸Abra el circuito en el que vaya a medir la corriente. (la tensión entre este punto y tierra no debe superar los 1000 V). ❹Conecte con seguridad las puntas de prueba, en serie con la carga. Conecte la alimentación del circuito sobre el que va a medir. ➎Lea el valor de la corriente en el visualizador. Nota: Es posible medir entre 10 y 20 A durante un máximo de 30 segundos. Después deje transcurrir 10 minutos para que se enfríe el instrumento. Aviso de entrada incorrecta: Aparece "FErr" cuando se conecta una punta de prueba a la entrada de corriente y el selector no está en escala de corriente correcta. - 14 - 220.Man.08.00 9/11/00 6:05 PM Page 15 F • Mesure de Courant CC et CA (voir fig. 5) ❶Connectez le cordon rouge à l’entrée 430mA pour mesures jusqu’à 430mA et à l’entrée 10A pour mesures jusqu’à 10A. Connectez le cordon noir à l’entrée COM. ❷Placez le sélecteur sur la gamme de courant appropriée et pressez le touche pour mesurer du courant continu ou du courant alternatif. Observez l’affichage de AC (= CA) et DC (= CC). ❸Ouvrez le circuit à mesurer (le potentiel à ce point par rapport à la terre ne doit pas dépasser 1000V). Connectez les pointes de touche solidement en série avec le circuit. ❹Mettez le circuit sous tension. ➎Lisez la mesure. Note: Si, dans la gamme de 10A, vous mesurez brièvement un courant supérieur à 10A, éteignez l’appareil, et laissez le refroidir pendant au moins 10 minutes. Avertissement d’Entrée: "FErr" est affiché quand un cordon de test est relié à une entrée de courant mais le sélecteur n’est pas mis sur la bonne gamme de courant. RESISTANCE MEASUREMENT (See Fig. 6) ❶Turn off any power to the circuit to be measured and discharge any capacitors. Any voltage present during a resistance measurement will cause inaccurate readings.❷Connect test leads as shown in figure 6. ❸Set Function/Range Switch to Ω position. ❹Connect test leads to circuit being measured. ➎Read resistance value on Digital Display. Open circuits will be displayed as “I.OL”. Note: When measuring very low resistances, use Relative Measurement to eliminate the test lead resistance (see Menu Functions, page 23). D • Widerstandsmessung (siehe Fig. 6) ❶Jede Spannung vom Meßkreis abschalten und Kondensatoren entladen. Eine am Meßkreis anliegende Spannung würde das Resultat verfälschen. ❷Rotes Meßkabel mit V•Ω Eingang und schwarzes mit COM verbinden. ❸Funktionsschalter auf Ω - Position stellen. ❹Meßspitzen mit Widerstand/ Schaltkreis verbinden. ➎meßwert ablesen. Ein offener Schaltkreis wird mit Überlast angezeigt. Anmerkung: Bei niedrigen Widerstandswerten mit Relativmessung (siehe Seite 23) den Widerstand der Meßkabel kompensieren. E • Medidas de Resistencia (vea Fig.6) ❶Apague la alimentación eléctrica al circuíto que desea medir y descargue los condensadores. La presencia de tensión causará imprecisión en las medidas de resistencia. ❷Conecte la punta de prueba roja a la entrada V-Ω y la negra a la entrada COM. ❸Ponga el selector de función en la posición de Ω. ❹Conecte las puntas de prueba a la resistencia o circuito que vaya a medir. ➎Lea el valor de la resistencia en el visualizador. Un circuito abierto se indicará como condición de sobrecarga. - 15 - 220.Man.08.00 9/11/00 6:05 PM Page 18 D • Dioden- und Transistortest (siehe Fig. 7) Der Diodentest zeigt den Spannungsabfall über den Diodendurchgang ❶ Rotes Meßkabel mit V-Ω Eingang und schwarzes mit COM Eingang verbinden. Hz mit ❷Funktionsschalter auf stellen . ❸Meßkabel % Diode verbinden rotes mit Anode; schwarzes mit Kathode. ❹Spannungsabfall in Durchlaßrichtung ablesen (ung. 0.6V für eine Silizium-Diode und 0.4V für eine Germaniumdiode. Eine offene V A um in Sperrichtung zu Diode wird mit Überlast angezeigt. ➎Verbindung umdrehen messen. Überlast zeigt eine gute Diode an. Anmerkung: Überlast in beiden A V Richtungen zeigt eine offene Diode an; eine niedrige Anzeige eine kurzgeschlossene Diode. Transistorübergänge können wie Dioden getestet werden. Bei Durchgangsmessung (auch bei kurzgeschlossenen Dioden) wird ein Dauerton abgegeben wenn der Widerstand unter 50Ω fällt. E • Comprobación de diodos y transistores (vea Fig.7) En esta prueba se mide la caída de tensión en la unión del diodo. ❶Conecte la punta de prueba roja a la entrada V-Ω y la negra a la entrada COM. ❷Ponga el Hz el extremo de la punta de selector de función en la posición . ❸Aplique % prueba roja al ánodo del diodo, y el de la negra al cátodo. ❹El visualizador indica la caída de tensión directa V(aproximadamente 0.6 V para diodos de silicio, o 0.4 V para A diodos de germanio). Una unión abierta se indica como condición de sobrecarga. ➎Invierta la conexión de las puntas de prueba para verificar la polarización inversa A V del diodo. La condición de sobrecarga indica un diodo en buen estado. Notas: La condición de sobrecarga en ambos sentidos indica un diodo abierto. Un valor bajo de tensión en ambos sentidos indica un diodo cortocircuitado. Las uniones de un transistor bipolar se comprueban como si fueran diodos. Al medir continuidad (también diodos en cortocircuito), el medidor emite un tono continuo si el valor de resistencia es inferior a 50 Ω . F • Test de Diodes et de Transistors (voir Fig. 7) V V Le test de diodes affiche la chute de tension à travers la diode. ❶Connectez le cordon rouge à l’entrée V-Ω et le noir à l’entrée COM. ❷Placez le sélecteur sur Hz les . ❸Connectez % pointes de touche à la diode – le rouge à l’anode, le noir à la cathode. ❹Lisez la chute de tension en direction passante (environ 0.6V pour une diode au Si; 0.4V pour une diode au Ge). Une diode ouverte est affichée par A pour mesurer en direction de bloquage. Une bonne "IOL". ➎Inversez la connection diode est affichée par "IOL". Notes: "IOL" dans les deux directions indique une A diode ouverte; une lecture basse indique une diode court-circuitée. Les jonctions de transistors peuvent être testées comme des diodes. Pour les mesures de continuité (et les diodes court-circuitées), l’instrument émet un ton continu quand la résistance est inférieure à 50Ω - 18 - 220.Man.08.00 9/11/00 6:05 PM Page 20 D • Logiktest (siehe Fig. 8) Der Logiktest zeigt ein TTL High, Low oder wechselndes Signal an. ❶Funktionsschalter auf Logiktest stellen. Die Anzeige zeigt IOL und das Wort "Logic" an. ❷Schwarzes Meßkabel mit Masse und rotes mit dem Meßpunkt verbinden. Ein Logik Low Signal wird mit dem nach-unten-zeigenden Dreieck und einem Ton angezeigt; ein Logik High Signal mit dem nach-oben-zeigendem Dreieck ohne Ton, und ein wechselndes Signal mit wechselnden Dreiecken und Ton. Über 15Hz ist der Ton unterbrochen; über 100Hz wird der Ton ein Dauerton. Über 200Hz bleiben beide Dreiecke angezeigt. Siehe " MEM" Fuktion zum Erfassen von schnellen Impulsen und einmaligen Signalwechseln. E • Test Lógico (vea Fig. 8) El test lógico indica una entrada TTL alta, baja o en transición. ❶Ponga el interruptor de rango en la posición lógica. La pantalla mostrará un "I.0L" y la palabra "Logic". ❷Conecte la punta de prueba negra al común del circuíto o tierra y la punta roja al punto de prueba. Aparecerá una indicación "LOW" con una flecha hacia abajo junto a un tono cuando el nivel sea bajo y el caso inverso "HIGH", cuando el nivel sea alto. Cuando la señal sea alternante, las flechas y los tonos cambiarán. Por encima de los 15 Hz., el tono podría ser intermitente, cambiando a estable cuando la frecuencia sea mayor de 100 Hz. Por encima de 200 Hz, las flechas permanecen estables en pantalla. Consulte las instrucciones de las teclas " MEM" para cuando se desea detectar pulsos rápidos y la espera en el cambio en los circuítos monoestables, sin tener que observar el medidor. F • Test Logique (voir fig. 8) Le test logique indique un niveau logique (TTL) haut, bas ou changeant. ❶Placez le sélecteur sur la position "LOGIC". IOL et le mot "LOGIC" sont affichés. ❷Connectez le cordon noir à la masse et le rouge au point à mesurer. Un niveau bas est indiqué par le triangle pointant vers le bas et un son; un niveau haut par le triangle pointant vers le haut et sans son et un niveau changeant par des triangles changeants et un son. En dessus de 15Hz le ton est intermittant – il devient continu au-dessus de 100Hz. Au-dessus de 200Hz les deux triangles sont affichés en permanence. Voir fonction " MEM" pour la capture d’impulsions rapides et transitions uniques. MENU FUNCTIONS LOGIC MEM REC MAX MIN AVG HOLD MIN MAX A REL RANGE MEM SLEEP OFF HOLD The model 220 meter has eight menu buttons to select higher level functions. All the buttons have an LCD display indicator that is either enabled, disabled or makes multiple changes with each successive press of that button. The use of each button is explained on the following pages. - 20 - 220.Man.08.00 9/11/00 6:05 PM Page 22 D • Max-/Min-/Mittelwertspeicherung Mit dieser Funktion werden minimale, maximale und Mittel-Werte in drei verschiedenen Registern gespeichert, bei gleichzeitiger Anzeige des aktuellen Wertes. Die Funktion steht für alle Meßfunktionen zur Verfügung, mit Ausnahme des Logik Tests. Automatische Abschaltung ist inaktiv und das Gerät bleibt im eingestellten Bereich. Anmerkung: Falls gewünscht, wählen Sie mit der RANGE Menü Funktion einen anderen Bereich bevor Sie die MINMAX Taste drücken. Stellen Sie den Wahlschalter auf die gewünschte Meßfunktion und verbinden Sie die Meßkabel mit dem Meßkreis (Siehe Beschreibung der Meßfunktionen). Drücken sie die MINMAX Taste um die Funktion zu aktivieren. REC wird angezeigt. Führen Sie eine Messung aus über einen längeren Zeitraum. Drücken Sie danach die MINMAX Taste einmal. REC MAX wird angezeigt zusammen mit dem Inhalt des Maximalwert-Speichers. Drücken Sie die MINMAX Taste ein zweites mal um den Wert des Minimalwertspeichers anzuzeigen (REC MIN angezeigt). Eine folgende Aktivierung der Taste zeigt den Mittelwert der letzten zehn Messungen bei zwei Messungen per Sekunde an (REC AVG angezeigt). Benützen Sie diese Funktion wenn Signalrauschen eine sichere Messung erschwert. Um die Funktion zu deaktivieren, drücken sie die Taste zwei Sekunden. Drücken Sie RANGE zwei Sekunden um nach automatischer Bereichswahl zurück zu kehren. E • Modo de grabación máximo/mínimo/valor medio La tecla de "MINMAX", arranca una función de grabación que almacena tres registros: máximo, mínimo y media, los cuales son actualizados de forma permanente, pudiendo visualizarse en pantalla, hasta que la grabación se desconecta. Esta característica, puede ser usada con todos los rangos de medición, excepto con "Logic". Cuando se habilita "MINMAX" se desconecta la función de apagado automático y el instrumento se bloquea en el rango actual. Nota: Use el menú de rango (RANGE), antes de pulsar MINMAX para seleccionar un rango diferente al actual. Para usar, ponga el interruptor de rango en el parámetro a ser medido y conecte el medidor al circuíto, como se indica en la sección GENERAL. A continuación pulse la tecla "MINMAX", hasta que aparezca en pantalla "REC MAX". El parámetro síendo medido mostrará la lectura máxima que la grabadora tiene en el registro MAX. Vuelva a pulsar la tecla "MINMAX" para visualizar el contenido del registro MIN. Cada vez que se pulse esta tecla la pantalla mostrará el registro siguiente en forma de bucle contínuo. a lectura media mostrada es la media de las 10 últimas lecturas realizadas a un ritmo de 2 por segundo. Utilice tambien esta posibilidad, cuando existan ruídos en la línea y se hace difícil aparezca solamente la palabra "REC" la - 22 - 220.Man.08.00 9/11/00 6:05 PM Page 24 E • Modo Relative Haga primero la medida y después active Relative Mode, cuando la lectura esté presente en el visualizador. Se almacena la medida como valor de referencia y la lectura pasa a cero. Después se resta este valor de referencia de las medidas subsiguientes, presentándose la diferencia en el visualizador. Valores majores que la referencia son positivos y negativos en caso contrario. F • Mesure Relative Prenez une mesure et puis activez le Mode Relatif, avec la mesure affichée. La valeur affichée est enregistrée comme référence et l’affichage est remis à zéro. La valeur ainsi enregistrée est déduite ensuite des mesures ultérieures et seulement la différence est affichée. Des valeurs plus grandes que la référence sont positives; des valeurs plus petites que la référence sont négatives. RANGE LOCK RANGE Locks the currently displayed range. Each subsequent push of the button moves to a higher range. From highest range the meter returns to the lowest range. D • Bereichssperre Sperrt den aktiven Bereich. Jeder weiterer Tastendruck wählt einen höheren Bereich.Auf den höchsten Bereich folgt wieder der niedrigste Bereich. Drücken Sie RANGE während zwei Sekunden um zur automatischen Bereichswahl zurückzukehren. E • Range Lock Bloquea la escala visualizada en ese momento. Después, cada pulsación de la tecla hace que se pase a la escala inmediatamente superior. Desde la escala superior se pasa de nuevo a la inferior. Pulse y mantenga la tecla de rango (RANGE), durante 2 segundos, para volver al auto-rango. F • Maintien de Gamme Maintient la gamme active. Chaque nouvelle pression de la touche sélectionne une gamme plus élevée. De la gamme supérieure l’instrument retourne dans la gamme inférieure. Pressez la touche RANGE pendant deux secondes pour retourner à la séléction automatique de gammes. - 24 - 220.Man.08.00 9/11/00 6:05 PM Page 25 PROBE HOLDTM Probe Hold keeps the measurement on the display for later HOLD viewing (even after test leads are removed from circuit). Select HOLD before taking a measurement. The meter beeps to indicate that a stable measurement has been recorded. D • Anzeigesperre Probe Hold erhält die Anzeige für späteres Ablesen (auch wenn die Meßkabel vom Schaltkreis getrennt sind). HOLD vor der Messung drücken. Ein Biepton meldet die Erfassung eines stabilen Meßwertes. E • Probe Hold Mantiene "congelada" la lectura presente en el visualizador para visualizarla más adelante (incluso después de desconectar las puntas de prueba del circuito). Seleccione HOLD antes de hacer una medida. El medidor emite un "bip" para indicar que ha registrado una medida estable. F • Maintien de Lecture Probe Hold maintient l’affichage pour lecture ultérieure (même quand les pointes de touche sont séparées du circuit). Activez HOLD avant la mesure. Un bip sonore confirme l’acquisition d’une mesure stable. AMPERAGE AC/DC SWITCH A The Amperage AC/DC Switch works in conjunction with the Range Switch’s amperage ranges to select the correct input The LCD will display the current selection and pressing the switch will alternate the selection. D • Gleich-/Wechselstromwahl Wahlschalter auf gewünschten Strombereich stellen und diese Taste drücken um Gleich(DC)- oder Wechsel(AC)- Strom zu wählen. DC und AC wird beim Drücken der Taste alternierend angezeigt. E • Interruptor de amperaje en AC/DC Este interruptor trabaja junto a el selector de rangos, a fin de elegir el valor apropiado de entrada. La pantalla muestra la selección elegida, alternando el rango cada vez que se pulse. F • Sélection de Courant CC ou CA Placez le sélecteur de courant sur la gamme appropriée et pressez ce bouton pour choisir du courant cc (DC) ou ca (AC). En pressant le bouton de façon répétitive, DC et AC sont affichés en alternance. - 25 - 220.Man.08.00 9/11/00 6:05 PM Page 26 LOGIC MEMORY The Memory button works only with the Range Switch in the “Logic” MEM position and enables and disables the display pulse indicator. Use the MEM feature to wait and indicate a pulse change, 1 to 0 or 0 to 1. If any pulse is detected the indicator will display and stay on, even if the pulse is too fast for the UP/DOWN arrow indicators to display. D • Logikspeicher Diese Funktion kann nur angewählt werden wenn der Funktionsschalter auf LOGIC steht, und aktiviert die Impulserfassung. Die Impulsanzeige erscheint (und bleibt erhalten) bei einem Wechsel des Logikpegels (1 nach 0 oder 0 nach 1), auch wenn dieser Wechsel zu schnell ist um mit der Dreieck-Anzeige angezeigt zu werden. E • Grabación de pulso lógico Este interruptor trabaja solamente con el interruptor de rango en la posición "Logic" y habilita o deshabilita el indicador de pantalla. Use la característica de memoria "MEM", cuando se quiere detectar un cambio de estado en el pulso, tanto si es de 0 á 1 o al revés. Si se detecta un pulso, el indicador lo mostrará y permanecerá en ese estado, incluso si es demasiado rápido para el indicador de flechas "UP/DOWN". F • Memoire d’Impulsions Cette fonction peut être activée quand le sélecteur est placé sur LOGIC. Le symbole indique un changement de niveau logique (1 vers 0 ou 0 vers 1), même si ce changement est trop rapide pour être indiqué par les triangles. AUTOMATIC POWER OFF (APO) BUTTON The Automatic Power Off (APO) button alternates the meter in and out of the SLEEP APO mode. When enabled, APO will be displayed in the LCD OFF and the meter will power off automatically 60 minutes after the last range switch change or mode button change. Move the Range Switch to the OFF position and then select a range to power ON the meter from an APO. D • Automatische Abschaltung Wenn diese Taste gedrückt ist (APO in der Anzeige), schaltet das Gerät automatisch nach ungefähr 60 Minuten Inaktivität ab. Sie können es wieder einschalten durch drehen des Funktionsschalters nach OFF und zurück nach einer Meßfunktion. - 26 - 220.Man.08.00 9/11/00 6:05 PM Page 27 E • Apagado Automático La tecla de apagado automático conecta/desconecta de modo alternativo el medidor. Cuando está conectada se mostrará la palabra "APO" en pantalla y el medidor se apagará de forma automática después que hayan pasado 60 minutos de la última medida o pulsación realizada. Actue sobre el interruptor de rango, poníendolo en la posición "OFF" y seleccione un rango, lo cual provocará que se active el medidor desde la condición "APO". F • Coupure Automatique Quand cette touche est pressée (APO est affiché), l’appareil s’éteint automatiquement après une heure d’inactivité. Vous pouvez rallumer l’appareil en tournant le sélecteur vers OFF et puis vers une fonction de mesure. DISPLAY BACKLIGHT BUTTON Model 220 has one of the best display backlights available in the industry. This button turns the backlight on and off. To conserve battery life, backlight will automatically turn off after approximately 60 seconds. D • Hintergrundbeleuchtungstaste Modell 220 hat eine der besten Hintergrundbeleuchtungen auf dem Markt. Diese Taste schaltet die Hintergrundbeleuchtung ein und aus. Um die Batterie zu schonen, schaltet die Hintergrundbeleuchtung nach 60 Sekunden automatisch ab. E • Tecla de iluminación de pantalla El modelo 220, tiene una de las pantallas con iluminación posterior mejores de la industria. Este tecla enciende y apaga dicha iluminación. A fin de ahorrar energía, la iluminación se apaga automaticamente, después de transcurridos 60 segundos. F • Bouton de rétro-éclairage Le Modèle 220 dispose d’un des meilleurs rétro-éclairages disponibles sur le marché. Ce bouton allume et éteint le rétro-éclairage. Afin d’économiser la pile, le rétro-éclairage s’éteint automatiquement après 60 secondes. SAFETY TEST LEADS The test leads included with your meter have shrouded banana plugs to eliminate the possibility of shock if the plugs accidentally pull out of the meter while making a measurement. The test leads also have insulated probe tips to avoid causing shorts when making measurements in dense component areas. Replacement part number for safety test leads is TL245. - 27 - 220.Man.08.00 9/11/00 6:05 PM Page 28 D • Sicherheitsmeßkabel Die Meßkabel haben versenkte Bananenstecker um elektrische Schläge zu vermeiden. Die Meßspitzen sind zum Teil isoliert, um Kurzschlüsse in dichten Schaltungen zu vermeiden. Diese Isolation kann entfernt werden. Ersatzteilnummer ist TL245. E •Puntas de Prueba de Seguridad Las puntas de prueba suministradas con el multímetro incluyen unos conectores de banana protegidos para eliminar la posibilidad de descargas eléctricas. Las puntas están parcialmente aisladas para evitar cortocircuitos en áreas con alta densidad de componentes. El usuario puede quitar dicho aislante si lo desea. (Ref: TL245). F • Cordons de Sécurité Les fiches banane des cordons sont munies de protecteurs fixes afin de supprimer les risques de chocs électriques. Les pointes métalliques sont partiellement isolées pour éviter des court-circuits dans des circuits denses. Cette isolation peut être enlevée. Numéro de commande: TL245. OTHER TEST LEADS AND ACCESSORIES DL243C DL248C TL245 TL35A CT231A CT232A CT234A Standard Test Lead Set Deluxe Test Lead Set Standard Replacement Test Leads Test Leads with Alligator Clips 150A AC Current Clamp 1000A AC Current Clamp 400A AC Current Clamp CT235 CT236A CT237 CT238 RF241 TC253A VC221A 1000A AC/DC Clamp 500A AC Clamp (mV output) 200A AC/DC Current Clamp 20A AC/DC Current Clamp 650MHz RF Probe Temperature Converter (900°C/1652°F) Padded Vinyl Case. Fits meter & holster. CT236A CT237 CT238 RF241 TC 253A 500A AC Stromzange (mV Ausgang) 200A AC/DC Stromzange 20A AC/DC Stromzange 650MHz RF Meßkopf Temperatur/Spannungsumsetzer (900°C/1652°F) Gepolsterte Vinyl-Tragetasche (fürMeter und Holster) D • Sicherheitsmeßkabel DL243C DL248C TC 253A TL245 CT231A CT232A CT234A CT235 Standard Meßkabelsatz Deluxe Meßkabelsatz Temperatur/Spannungsumsetzer Ersatzsicherheitsmeßkabel (900°C/1652°F) 150A AC Stromzange 1000A AC Stromzange 400A AC Stromzange 1000A AC/DC Stromzange VC221A E • Accesorios opcionales DL243C DL248C TL245 CT231A CT232A CT234A CT235 Juego de puntas de prueba Juego de puntas de prueba Puntas de prueba de seguridad Pinza de corriente 150 A CA Pinza de corriente 1000 A CA Pinza de corriente 400 A CA Admite elmedidor sin funda Pinza de corriente 1000 A CA/CC CT236A CT237 CT238 RF241 TC253A VC221A - 28 - Pinza de corriente 500 A CA Admite el medidor con funda (salida mV) Pinza de corriente 200 A CA/CC Pinza de corriente 20 A CA/CC Sonda de RF 650 MHz (calidad especial) Convertidor de temperatura (900ºC/1652ºF) de repuesto Estuche de vinilo acolchado 220.Man.08.00 9/11/00 6:05 PM Page 32 Genauigkeit, 430µA-430mA Bereiche±(0.8%vMW +2Dgt) 10A Ber. ±(2.0%vMW +3Dgt) Spannungsabfall, 430µA-43mA Ber.: 500mVDC; 430mA Ber.: 1.0V DC; 10A Ber.:500mV DC Überlastschutz: mA Eingang: 0.5A/500V Sicherung (6.35x32mm); 10kA Trennver-mögen;10A Eingang: 15A/600VSicherung;100kA Trennvermögen(10x38mm, UL gelistet). 4.3-430kΩ Ber. ±(0.7%vMW +2Dgt), 4.3MΩ Ber. ±(1.0%vMW +4Dgt), 43MΩ Ber. ±(2.0%vMW +4Dgt) Max Leerlaufspannung: 3.0V DC im 430Ω Bereich; 0.6V in allen anderen Bereichen. Überlastschutz, alle Ber.: 500VDC oder AC eff Dioden-/Durchgangstest Wechselstrom (45Hz-1kHz) Bereiche: 430µA, 43mA, 430mA, 10A Auflösung, 430µA Bereich: 100nA Genauigkeit: 430µA430mA: ±(1.2%vMW +4Dgt) 10A input ±(2.5%vMW +4Dgt) Spannungsabfall, 430µA, 43mA Ber.: 500mV eff.; 430mA Ber.: 1.0V eff.; 10A Ber.: 500mV eff. AC Umsetzung: MitteWwertbildend, RMS Anzeige (Sinuswellenform) Überlastschutz: siehe Gleichstrom. Widerstand Bereiche: 430, 4.3k, 43k, 430k,4.3M, 43MW Auflösung, 430Ω Bereich: 100mΩ Genauigkeit, 430Ω Ber. ±(0.8%vMW +4Dgt), Bereich: 4.3V Auflösung: 1mV Genauigkeit: ±(1.5%vMW +2Dgt) Kurzschlußstrom: 1.0mA Max. Leerlaufspannung: 3.2VDC Ansprechzeit: <500ms. Ansprechschwelle: 50Ω±25Ω Überlastschutz: 500VDC oder AC eff Logik Test Logikart: TTL 5VDC Schwelle: Logik 1 (Hoch): 2.8V, Logik 0.8V, Logik 0 (Niedrig): 0.80±5V Frequenzbereich: 20MHz Impulsbreite: 25nsec minimum Taktverhältnis: >20% und <80% Anstiegszeit: 10µsec Ahzeige: 40ms Ton bei Logik 0(OL) Wiederholrate: 1M PPS Überlastschutz: 500V DC oder AC eff Gefährliche Spannungsanzeige Schwelle: >30V eff oder >60V DC ESPECIFICACIONES Especificaciones generales Visualizador: LCD de 3-3/4 dígitos, 4300 cuentas, indicadores de función, de unidades y de menu Indicación de polaridad: Automática Indicación de sobrecarga: "I.OL" Indicación de "pila baja": <50 horas, no se garantiza la precisión en las mediciones realizadas. Frecuencia de refresco de la lectura: 2 veces/ segundo, nominal Temp. de funcionamiento. ( 0 a 80% H.R., sin condensación): 0 a 50 ºC, Temp. de almacenamiento: -20 a 40 ºC, 0 a 80% H.R. sin condensación, sin pila. Coefic. de temper.: 0.1 x (especif. de preci sión) por ºC ( 0°C a 18°C o 28°C a 50°C) Fusibles: 0.5A/500V; N.d.I. 10kA15A/600V; N.d.I. 100kA Alimentación: Pila normal de 9 V, NEDA 1604, JIS 006P, IEC 6F22 Apagado automático: El medidor se apaga después de 30 minutos sin actividad o cuando la pantalla está en "APD". No enmodo Min/Max. Duración de la pila (típ.): alcalina, 300 horas El uso de la iluminación de panel, produce un consumo extra de potencia, lo cual, hace que decrezca significamente la vida de la misma. Tiene un auto apagado a los - 32 - 220.Man.08.00 9/11/00 6:05 PM Page 33 60 seg. Dimensiones, sin funda (AlxAnxPr): 183 x 84 x 47 mm Peso (pila incluida): 484 g Accesorios: Puntas de prueba, fusible de repuesto* (0.5A/500V), pila* y Manual de Instrucciones * en el instrumento Material de la carcasa: Termoplástico de inflamabilidad retardada, gran resistencia a impactos. Seguridad: Según normas EN61010-1 Cat II - 1000V; Cat III - 600V EMC: Según EN55011 y EN61000-4-2 Este producto cumple los requisitos de las siguientes Directivas de la Comunidad Europea: 86/336/EEC (Compatibilidad Electromagnética) y 73/23/EEC (Baja Tensión), con enmiendas según 93/68/EEC (Marcado CE). No obstante, la presencia de ruido eléctrico o campos electromagnéticos intensos en las proximidades del equipo pueden introducir perturbaciones en los circuitos de medida. Los instrumentos de medida también responden a las señales no deseadas que puedan estar presentes en los circuitos de medida. El usuario deberá tomar las precauciones necesarias para evitar obtener resultados incorrectos cuando realiza medidas en presencia de interferencias electromagnéticas. Especificaciones eléctricas Valores de precisión a 23 ºC ±5 ºC, H.R.<80% sin condensación), garantizados per un ano Tensión CC Escalas: 430mV, 4.3, 43, 430, 1000V Resolución, escala 430mVV: 0.1 mV Precisión, todas escalas: ±(0.25%lect +2dgt) Impedancia de entrada: 10 MΩ Rech. modo común (hasta 1000VCC: >120 dB) Rechazo modo normal (50-60 Hz): >60 dB Protección sobrecarga: 1000 VCC o CA pico; protección contra transitorios: 6 KV. Tensión CA Escalas: 430mV, 4.3, 43, 430, 750V Precisión: esc. 430mV @ 45-100Hz ±(1.5%lect +4dgt) esc. 4.3-430V @ 45-500Hz ±(1.0%lect +4dgt), esc. 750V @ 45-60Hz ±(1.0%lect +4dgt) esc. 4.3-43V @ 500Hz-5kHz ±(2.0% lect +5dgt), esc. 430V @ 500Hz-2kHz ±(2.0% lect +5dgt) esc 750V @ 60-500Hz ±(2.0% lect+5dgt). Resolución, escala 430mV: 100µV Impedancia de entrada: 10 MΩ// <100pF Tipo de conversión: Valores medios / pantalla en modo RMS. Protección sobrecarga, 1000Vcc/750Vrms; Corriente CC Escala 430µA, 43mA, 430mA, 10A Resolución, escala 430µA: 100nA Precisión, esc. 430µA-430mA: ±(0.8% lect +2dgt) esc. 10A: ±(2.0% lect +3dgt) Carga de tensión, esc. 430µA-43mA: 500mVDC; esc. 430mA: 1.0VDC; esc. 10A: 500mVDC Protección sobrecarga: entrada mA: fusible 0.5A/500V; Nivel de interrupción:10kA. Entrada 10A: fusible ceramico rapido 15A/600V; Nivel de interrupción: 100kA; dimensiones: 10x38mm, listado UL Corriente CA (45Hz-1kHz) Escalas: 430µA, 43mA, 430mA, 10A Resolución, escala 430µA: 100nA Precisión, escalas 430µA-430mA: ±(1.2%lect+4dgt) escala 10A: ±(2.5%lect +4dgt) Carga de tensión, escalas 430µA, 43mA: 500mVrms, esc. 430mA: 1.0Vrms; esc. 10A: 500mVrms Tipo de conversión: Valores medios / pantalla en modo RMS. Factor de cresta: 1:1 hasta 5:1 Protección sobrecarga: vea corriente CC. Resistencia Escalas: 430, 4.3k, 43k, 430k,4.3M, 43MΩ Resolución, escala 430Ω: 100mΩ Precisión, esc.430Ω: ±(0.8%lect +4dgts), - 33 - 220.Man.08.00 9/11/00 6:05 PM Page 34 esc. 4.3-430kΩ: ±(0.7%lect +2dgts), esc 4.3MΩ: ±(1.0%lect +4dgts), esc 43MΩ: ±(2.0%lect +4dgts) Prot. sobrec., todas esc.: 500 V CC o CA ef. Tensión de circuito abierto: escala 430Ω: 3.0 VCC tipico; otras escalas: 0.6 VCC tipico. Prueba de diodos, Continuidad Escalas: 4.3V Resolución: 1mV Precisión: ±(1.5%lect +2dgt) Corriente de cortocircuito: 1.0mA Tensión de circuito abierto: 3.2Vcc Tiempo de respuesta: <500ms Indicación audible, continuidad: 50Ω±25Ω Protección sobrecarga.: 500V CC o CA ef. Niveles de disparo: 1 (alto): 2,8V±0,8V. 0 (bajo): 0,8V±0,5V Ancho de respuesta: 20 Mhz. Ancho de pulsos: 25 nseg. mínimo. Ciclo de trabajo: >20% y <80% Tiempo de ataque del pulso: 10 microseg. Ritmo de repetición: 1 M PPS Indicación:”Bip” de 40ms lógico 0 (bajo) Protección por sobre- carga: 500 VDC ó AC efectivos. Indicacion tensión peligrosa Niveles: Mayor de 30VRMS y 60 VDC. F specifications Test Lógico Tipo de lógica: TTL 5.0 VDC SPECIFICATIONS Spécifications Générales Afficheur: LCD 3-3/4 digits, 4300 points, indication d’unités et de fonctions. Indication de Polarité: Automatique Indication de Dépassem. de Calibre: "I.OL" Indication de pile déchargée: . Restent 50 heures. La précision n’est plus garantie Taux de mesure: 2/sec, nominal. Température de fonctionn.: (0 à 80% H.R. sans condensation): 0°C à +50°C Température de Stockage: -20°C à 40°C, 0 à 80% HR, sans condens., pile enlevée Coefficient de température: <0.1 x (préc. spécif.) par °C (0°à 18°C et 28°à 50°C) Fusibles: 0.5A/500V - pouv. coup.10kA 15A/600V - pouv. coup. 100kA Alimentation: Pile 9-volt standard, NEDA 1604, JIS 006P, IEC 6F22 Coupure automatique: après 30 minutes d’inactivité et APD affiché. Pas en fonction Min/Max. Autonomie, alcalin (typiq.): 300 heures. Le rétroéclairage consomme beaucoup de courant est diminue sensiblement la durée de vie de la pile. Coupure automatique après une minute. Dimensions, sans gaine (HxLxP): 183 x 84 x 47 mm Poids (avec pile): 484 gr Accessoires: une paire de cordons de mesure, un fusible de réserve (0.5A/500V)*, une pile*, et ce manuel. ( * installé) Matériau de boîtier: thermoplastique résistant au feu et aux chocs. Sécurité: Conforme à EN61010-1 Cat II - 1000V; Cat III - 600V. EMC: selon EN55011 et EN61000-4-2. Ce produit est conforme aux exigences des directives suivantes de la Communauté Européenne: 89/336/EEC (Compatibilité Electromagnétique) et 73/23/EEC (Basse Tension), modifiée par 93/68/EEC (CE Marking). Cependant, du bruit électrique ou des champs électromagnétiques intenses dans la proximité de l’instrument peuvent influencer le circuit de mesure. L’instrument peut égale-ment être perturbé par des signaux parasytes dans le circuit mesuré. L’utilisateur doit être vigilant et prendre des précautions appropriées pour éviter des résultats erronés quand les mesures sont prises en présence d’interférences électromagnétiques. - 34 - 220.Man.08.00 9/11/00 6:05 PM Page 36 OWNER/DISTRIBUTOR LEVEL MAINTENANCE If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem: ❶ Check the battery. ❷ Review the operating instructions for possible mistakes in operating procedure. ❸ Inspect and test the Test Probes for a broken or intermittent connection. ❹ Inspect and test the fuse. See Fuse Replacement. Except for the replacement of the battery or fuse, repair of the multimeter should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. D• Wartung & Reparatur Prüfen Sie zuerst folgende Fehlerquellen: Meßkabel (Brüche), Anschluß, Zustand von Batterie und Sicherung, richtiger Meßvorgang, Eingangs- und Bereichsgrenzen, usw. Mit Ausnahme des Batterie- und Sicherungswechsels soll jede Reparatur nur durch eine durch Wavetek anerkannte Servicestelle durchgeführt werden. Das Gerät kann mit einer milden Seifenlösung gereinigt werden. Sparsam auftragen und vor Gebrauch gut trocknen lassen. E •Maintenimiento y Reparación Para identificar la causa del problema: Compruebe la pila; revise las instrucciones de uso; inspeccione las puntas de prueba por si hay una conexión rota o intermitente; inspeccione la pila y el fusible. Excepto la sustitución de la pila o el fusible, cualquier trabajo de reparación del multímetro debe hacerse exclusivamente por personal técnico cualificado para este tipo de reparaciones. Para limpiar la carcasa puede utilizarse una solución suave de agua y detergente. Aplique con un paño suave y deje secar antes de usar el medidor. F • Maintenance & Réparation Avant d’expédier votre multimètre pour réparation, vérifiez les cordons de mesure (rupture), pile et fusible, connections, procédure de mesure, limites d’entrée et de calibres, etc. Excepté pour le remplacement de la pile et du fusible, toute réparation doit être effectuée uniquement par un Centre de Services agrée par Wavetek. Vous pouvez nettoyer le boîtier avec un détergent doux. Appliquez parcimonieu- sement et laissez sécher complètement avant utilisation. - 36 - 220.Man.08.00 9/11/00 6:05 PM Page 38 Ref. KTK-15 oder Wavetek Meterman Ref 3000-400-214. • 430mA Eingang: 0.5A/500V Sicherung (klein) – Wavetek Meterman Ref. FP385. (Eine Ersatzsicherung ist im Gerät enthalten. Beim Ersetzen der Ersatzsicherung sicherstellen daß diese gut im Sicherungshalter sitzt. Käme sie los, dann könnte sie einen Kurzschluß verursachen.) Gerät wieder zusammensetzen. Schrauben nicht zu fest anziehen um das Gewinde des Gehäuses nicht zu beschädigen. E • Sustitución de la pila y los fusibles Advertencia: Para evitar el peligro de descarga eléctrica, apague el medidor y desconecte las puntas de prueba antes de abrir la tapa posterior. Advertencia: Utilice solamente fusibles equivalentes a los especificados. Ponga el medidor boca abajo sobre una superficie limpia. Separe las dos mitades de la carcasa (anterior y posterior) aflojando los 3 tornillos que las mantienen unidas. Asegúrese de que o entre suciedad o grasa al medidor. No toque ningún componente de la placa. Sustitución de la pila: extraiga la pila alcalina de 9 V (NEDA tipo 1604, JIS006P o IEC 6F22) y cámbiela por otra equivalente. Sustitución de los fusibles: Cambie los fusibles que hayan saltado por otros equivalentes: • Entrada 10 A: fusible largo 15A/600V – Little fuse ref. KLK-15, Bussman ref. KTK15 o Wavetek Meterman ref. 3000-400-214. • Entrada 430 mA: fusible corto 0.5A/500V - Wavetek Meterman ref. FP385. (Hay un fusible de repuesto en el interior de la carcasa. Al cambiar este fusible, asegúrese de insertarlo firmemente en el portafusibles para evitar que se salga y cause un cortocircuito). Vuelva a cerrar el instrumento. Advertencia: Si no apaga el multímetro antes de cambiar la pila, podría causar daños al instrumento y a la pila F • Remplacement Pile et Fusible Avertissement: Pour éviter des chocs électriques, éteignez l’appareil et retirez les cordons de test avant d’ouvrir le boîtier. Avertissement: L’utilisation d’un fusible incorrect peut entraîner des blessures graves. Déposez l’appareil, face avant vers le bas sur une surface propre et capitonnée. Dévissez et enlevez le boîtier arrière. Assurez-vous que ni poussière, ni huile ni autre contaminant n’entrent dans l’appareil. Ne touchez pas le circuit electrique. Remplacement de la pile: Soulevez la pile du boîtier arrière et enlever la manche de protection. Déconnectez la pile. Appliquez la manche de protection sur une nouvelle pile, type NEDA 1604, JIS 006P ou IEC 6F22, et installez-la en observant la polarité. - 38 - 220.Man.08.00 9/11/00 6:05 PM Page 40 D • Reparatur Lesen Sie die Gewährl ei stung bevor Sie eine Reparat ur unter oder außerhalb Gewährleistung anfragen. Unter Gewährleistung bringen Sie bitte das def ekte Gerät zu ei ner aner kannten Wavetek Meterman Verkaufsstelle oder Servicestelle füreinen direkten Umtausch. Außerhalb Gewährlei st ung senden Sie das Gerät zu einer Wavetek Meterman anerkannten Servicestelle. Bitte informieren Sie sich bei Wavetek Meterman oder ihrem Fachhändler nach der dichtst beigelegen Adresse und nach aktuellen Reparaturgebühren. Bitte senden Sie folgende Informationen und Dokumente mit: Firmenname, Kundenname, Adresse, Telefoonnummer, Kaufnachweis (für Reparaturen unter Gewährl eistung), ei ne kurz e Beschr eibung der gewünschten Handlung, und di e gefordert e Bezahl ung ( Eingr iffe außerhal b der Gewährleistung). Bitte auch Testkabel beifügen. Bezahlungen in Form eines Checks, Bezahlungsformulieren, Kredietkarte mit Verf alldatum, usw. bitte in Namen der Servicestelle aufstellen. Bitte Multimeter (Frei) senden an: in U.S.A. in Canada in Europa Wavetek Meterman Wavetek Meterman Wavetek Meterman 1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K. Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824 Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409 oder an die Ihnen mitgetei lte Adresse. Multimeter wird (Frei) zurück geschickt. E • Reparación Lea las condiciones de garantía, al principio de este manual, antes de solicitar cualquier reparación dentro o fuera de garantía. Si la reparación es en garantía, puede llevar el multímetro defectuoso a cualquier Distribuidor Autorizado o Centro de Servicio de Wavetek Meterman, donde le cambiarán en mano el producto por otro igual o similar. Para reparaciones fuera de garantía deberá enviar el multímetro a un Centro de Servicio de Wavetek Meterman. En Wavetek Meterman, o en su Distribuidor o punto de venta, le indicarán el Centro de Servicio más próximo y las tarifas de reparación vigentes. La documentación que acompañe a todo multímetro enviado para reparación debe incluir los siguientes datos: nombre de la empresa, persona de contacto, dirección, número de teléfono, prueba de compra (para reparaciones en garantía), una breve descripción del problema o el servicio requerido y, en caso de reparaciones fuera de garantía, si desea presupuesto previo. - 40 - 220.Man.08.00 9/11/00 6:05 PM Page 41 Por favor envíe las puntas de prueba con el multímetro. El importe de la reparación se enviará en forma de cheque, tarjeta de crédito con fecha de expiración u orden de pago a favor de Wavetek Meterman o del Centro de Servicio específico. El multímetro se enviará a portes pagados a una de las siguientes direcciones, o al Centro de Servicio que le hayan indicado: en EE.UU. en Canadá en Europa Wavetek Meterman Wavetek Meterman Wavetek Meterman 1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K. Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824 Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409 Wavetek Meterman devolverá el multimetro reparado a portes pagados. F • Réparation Lisez la garantie au début de ce manuel avant de demander une réparation sous garantie ou hors gar antie. Pour une réparation sous garantie , adressez-vous à votre revendeur Wavetek Meterman ou à un centre de services agréé par Wavetek Meterman pour un échange direct. Pour une réparation hors garantie, envoyez votre multimètre à un Centre de Services agrée par Wavetek Meterman . Téléphonez à Wavetek Meterman ou demandez à votre revendeur pour l’adresse la plus proche. Pour les réparations hors garantie, demandez dabord les tarifs. Joignez les informations et documents suivants: nom de sociètè, nom du client, adresse, numéro de téléphone, preuve d’achat (pour réparations sous garantie), une brève description de l’intervention souhaitée et le payement (pour réparations hors garantie). Ajoutez également les cordons de test. Le payement, sous forme de chèque, virement, carte de crédit avec date d’expiration, etc. doit êtr e éta bli au nom du Centre de Servic es. Le multimètre doit être envoyé port payé à: en U.S.A. en Canada en Europe Wavetek Meterman Wavetek Meterman Wavetek Meterman 1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K. Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824 Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409 ou à l’adresse communiquée. Le multimètre vous sera renvoyé port payé. - 41 -
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Wavetek Meterman 220 Manual de usuario

Categoría
Multimetros
Tipo
Manual de usuario
Este manual también es adecuado para