Air Vent NPSG8 Instrucciones de operación

Tipo
Instrucciones de operación

Este manual también es adecuado para

Part No. 18365
Installation Instructions
Use this unit only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Utilice esta unidad solamente de la manera indicada por el
fabricante. Si tiene alguna duda, contacte al fabricante.
Roof-Mounted Solar Attic Ventilator
Ventilador de ático a energía solar, de montaje en techo
Model NPSP8WW
Modelo NPSP8WW
Important Safety Information
Información importante de seguridad
IMPORTANT: Read all warning messages and instructions
before starting installation of this fan. Failure to follow these
safety instructions can result in injury or even death. If you need
assistance in understanding these instructions or have questions
or comments, please call 309-692-6969.
ELECTRICAL HAZARD
DANGER: Watch out for existing electrical wiring and other utility
wires or pipes when selecting a location for the fan. Do not install
the fan where there is electrical wiring in the way. Select another
location or have a qualified electrician move the wiring to a
different location.
LACERATION HAZARDS
DANGER: This fan has an unguarded fan blade. Do not use in
locations which are readily accessible to people or animals. Do
not let children play in an attic where this fan has been installed.
Contact with this fan while in operation can result in injury or even
death.
DANGER: Keep the solar panel covered by its protective
packing until the fan is mounted or at anytime the motor or fan
blade are being serviced. This fan is controlled by a solar panel
it may start at any time the solar panel is exposed to sunlight.
Contact with the fan blades while the fan is operating can result
in serious injury.
WARNING: This product has sharp metal edges that can cut
your hands. Wear canvas work gloves while handling the fan
during installation.
CARBON MONOXIDE HAZARDS
DANGER: Carbon monoxide is a colorless, odorless gas that
can kill. Carbon monoxide may be drawn into the house by the
operation of this fan if your fuel-burning equipment is not properly
maintained and vented or if you lack adequate attic venting.
You should check the flue of your hot water heater and furnace to
see that the pipes are intact and sealed. Request an inspection
from your fuel supplier (gas company or heating oil company) or
from a municipal building inspector if you have any questions
about the safety of your fuel-burning equipment.
OTHER HAZARDS
DANGER: For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors. Use of this
fan to exhaust hazardous, explosive or flammable materials may
result in a fire or explosion, causing injury or death.
You must also check the number and size of your intake vents. A
total of at least 2.7 square feet of unobstructed intake venting in
the soffit or under-eaves must be available for safe operation of
this ventilator. If you have less than the amount specified above,
STOP and install additional vents before proceeding.
IMPORTANTE: Antes de comenzar a instalar este ventilador, lea todos los
mensajes de advertencia y las instrucciones. El no seguir estas
instrucciones de seguridad puede causar lesiones o incluso la muerte. Si
necesita asistencia para comprender estas instrucciones o desea hacer
preguntas o comentarios, llame al 309-692-6969.
RIESGO ELÉCTRICO
PELIGRO: Cuando elija un lugar para el ventilador, preste atención a la
existencia de cableado eléctrico y otros cables o tubos de servicio. No
instale el ventilador donde exista cableado eléctrico. Seleccione otro lugar
o solicite a un electricista especializado que traslade el cableado a otra
ubicación.
RIESGO DE LACERACIONES
PELIGRO: Este ventilador tiene aspas no protegidas. No lo utilice en
lugares fácilmente accesibles a personas o animales. No permita que los
niños jueguen en un ático donde se haya instalado este ventilador. El
contacto con este producto en funcionamiento puede ocasionar lesiones o
incluso la muerte.
PELIGRO: Mantenga el panel solar cubierto con su envase protector hasta
que se instale el ventilador o cada vez que el motor o el aspa del ventilador
reciban servicio. Este ventilador es controlado por un panel solar, por lo
que puede ponerse en funcionamiento toda vez que el panel solar esté
expuesto a la luz solar. El contacto con las aspas del ventilador mientras
este está en funcionamiento puede ocasionar graves lesiones.
ADVERTENCIA: Este producto tiene bordes metálicos filosos que pueden
cortarle las manos. Mientras manipula el ventilador durante la instalación,
utilice guantes de trabajo de lona.
RIESGO DE MONÓXIDO DE CARBONO
PELIGRO: El monóxido de carbono es un gas incoloro y sin olor que puede
provocar la muerte. El funcionamiento del ventilador puede llevar este gas
al interior de la casa si el equipo que consume combustible no se mantiene
y ventila correctamente, o si no se dispone de una ventilación adecuada en
el ático.
Es aconsejable verificar el cañón de la chimenea del calentador de agua y
el horno para garantizar que la tubería esté intacta y sellada. Si tiene
alguna pregunta sobre la seguridad del sistema de escape de sus equipos
que consumen combustible, solicite una inspección a su proveedor de
combustible (compañía de gas o de aceite combustible), o bien a un
inspector municipal de construcción.
OTROS RIESGOS
PELIGRO: Para ventilación general únicamente. No utilice el producto
para expeler materiales o vapores peligrosos o explosivos. El uso de este
ventilador para expeler materiales peligrosos, explosivos o inflamables
puede dar lugar a un incendio o una explosión y causar lesiones o la
muerte.
También debe verificar la cantidad y el tamaño de los respiraderos de
entrada. Para que este ventilador funcione en forma segura, se requiere un
total de al menos 2.7 pies cuadrados de entrada de ventilación sin
obstrucciones en el sofito o debajo del alero. Si usted no dispone del
espacio especificado, SUSPENDA la instalación del ventilador e instale
respiraderos adicionales antes de continuar.
Page 2 of 6
Illustration – 1 Ventilator Location
Ilustración
1 Ubicación del ventilador
Illustration – 2 Drilling Guide Hole
Ilustración – 2 Taladrado del orificio de
guía
ROOF-MOUNT SOLAR POWER VENTILATOR
INSTALLATION INSTRUCTIONS
NOTE: Air intake openings must be installed for proper
exhaust operation. Best results will be obtained if these
openings are located around the eaves. Rectangular soffit
vents or continuous soffit vents are suggested.
Sq. Ft. of Air Intake
Model
Opening Needed
NPSP8WW 2.7
TOOLS NEEDED:
x electric drill x phillips screw driver
x 1/2” drill bit x utility knife
x jig or sabre saw x 1/4” nut driver
x tape measure x caulk gun
x pencil or marker x work gloves
x hammer x safety glasses
MATERIALS NEEDED:
x roofing nails (ring shank recommended)
x caulk and/or roofing cement
WHAT COMES IN THE CARTON:
x roof-mount fan and motor assembly
x pre-wired solar panel
x four (4) solar panel mounting brackets
x eight (8) #8 x 1/2” sheet metal screws
x four (4) #10 x 1” hex head screws with rubber washer
1. SELECT VENTILATOR LOCATION
Select a location close to the ridgeline
on the backside of the house. The
ventilator should be installed near the
center of the roof for optimum airflow.
Refer to Illustration 1. If installing
multiple fans, space them evenly across
the roof. From the roof, measure the
distance to the ridgeline and to one end
of the roof. Note these dimensions for
use in Step 2.
2. DETERMINE EXACT VENTILATOR
POSITION
Using the dimensions obtained on the
roof in Step 1, locate the same position
inside the attic. Select the closest
centered location between two rafters to
establish the center of the roof mount
powered attic ventilator. From the attic,
drill a guide hole through the roof at the
location centered between rafters.
Refer to Illustration 2. Place an object
through the hole for quick identification
from the roof.
INSTRUCCIONES DE INSTALACIÓN DEL VENTILADOR A
ENERGÍA SOLAR DE MONTAJE EN EL TECHO
NOTA: Deben instalarse aberturas de toma de aire para el
correcto funcionamiento del ventilador. Los mejores resultados se
logran si estas aberturas se encuentran alrededor del alero. Se
sugieren respiraderos rectangulares o continuos en el sofito.
Pies cuadrados de abertura necesaria
Modelo
para toma de aire
NPSP8WW 2.7
HERRAMIENTAS NECESARIAS:
x taladro eléctrico x destornillador Phillips
x broca de taladro de 1/2 pulg. x cuchillo utilitario
x sierra de vaivén o caladora x llave para tuercas de 1/4 pulg.
x cinta métrica x pistola calafateadora
x lápiz o marcador x guantes de trabajo
x martillo x anteojos de protección
MATERIALES NECESARIOS:
x clavos para techo (se recomienda de cuerpo estriado)
x calafate o cemento para techar
CONTENIDO DE LA CAJA:
x ventilador de techo y conjunto del motor
x panel solar precableado
x cuatro (4) ménsulas de montaje para el panel solar
x ocho (8) tornillos para chapa n.° 8 x 1/2 pulg.
x cuatro (4) tornillos hexagonales n.°10 x 1 pulg. con arandela
de goma
1. SELECCIONE EL LUGAR DEL
VENTILADOR
Seleccione un lugar cerca de la cumbrera
en la parte de atrás de la casa. El
ventilador debe instalarse cerca del centro
del techo para lograr un flujo de aire
óptimo. Vea la ilustración 1. Si va a
instalar varios ventiladores, distribúyalos
de manera uniforme a lo ancho del techo.
Desde el techo, mida la distancia hasta la
cumbrera y hasta un extremo del techo.
Anote estas dimensiones para usarlas en
el Paso 2.
2. DETERMINE LA POSICIÓN EXACTA
DEL VENTILADOR
Usando las dimensiones obtenidas en el
techo en el Paso 1, ubique la misma
posición dentro del ático. Seleccione el
lugar más cerca del centro entre dos vigas
para establecer el centro del ventilador de
ático a energía solar de montaje en el
techo. Desde el ático, taladre un orificio
de guía a través del techo en el lugar
centrado entre dos vigas. Vea la
ilustración 2. Pase algún objeto por el
orificio para poder ubicarlo fácilmente
desde el techo.
Page 3 of 6
Illustration – 3 Hole in Roof for Ventilator
Ilustración – 3 Orificio en el techo para el
ventilador
Illustration – 4 Trimming Roof Covering
Materials
Ilustración – 4 Recorte de los materiales
de revestimiento del techo
Illustration – 5 Solar Panel Mounting
Bracket Assembly
Ilustración – 5 Conjunto de ménsulas de
montaje del panel sola
r
3. MARK AND CUT HOLE IN ROOF
From the roof, draw a 14-1/2” diameter circle centered on
the guide hole created in Step 2 using the template on the
carton. Cut and remove all roof shingles (and deck) inside
the 14-1/2” diameter circle using a jig or sabre saw. Refer
to Illustration 3. NOTE: Do not cut through any rafters.
Cutting a rafter may jeopardize the structural integrity of
the roof.
4. TRIM ROOF COVERING MATERIALS
Using a utility knife, cut an extra 1” off the top half of the
hole (shingles only) to allow room for placing and
positioning the flange. Refer to Illustration – 4.
5. INSTALL SOLAR PANEL MOUNTING BRACKETS
Locate the four (4) sets of two (2) holes on the underside
of the solar panel frame. Using a phillips screw driver and
the eight (8) included #8 sheet metal screws, secure the
four included brackets to the frame as shown in Illustration
– 5.
6. SELECT PANEL LOCATION AND ROUTE WIRE
Select a location for the solar panel with a southern exposure
for optimal solar collection. NOTE: Avoid locations that
experience afternoon shade. Next, determine the routing for
the wire from the panel to the fan location. NOTE: It is
acceptable for the wire to be installed on top of the roof
covering material. However, if routing the wire through the
attic is preferred as shown in Illustration 6, complete the
following steps:
x Drill a hole in the roof deck near the top of the solar panel
location, preferably under a shingle.
x Insert terminated wire ends through the hole into the attic.
Leave only enough wire on top of the roof so that the wire
is not under tension at the selected panel location.
x Caulk around the wire in the hole.
3. MARQUE Y CORTE UN ORIFICIO EN EL TECHO
Desde el techo, trace un círculo de 14-1/2 pulg. de diámetro
centrado en el orificio de guía creado en el Paso 2 usando la
plantilla que viene en la caja. Corte y retire todas las tejas del
techo (y el revestimiento) dentro del círculo de 14-1/2 pulg. de
diámetro usando una sierra de vaivén o caladora. Vea la
ilustración 3. NOTA: Tenga cuidado de no cortar ninguna viga.
Si corta una viga podría poner en juego la integridad estructural del
techo.
4. RECORTE LOS MATERIALES DE REVESTIMIENTO DEL
TECHO
Con un cuchillo de utilería, corte una pulgada extra de la parte
superior del orificio (solamente las tejas) para hacer lugar para
colocar y ubicar la pestaña. Vea la ilustración – 4.
5. INSTALE LAS MÉNSULAS DE MONTAJE DEL PANEL
SOLAR
Localice los cuatro (4) grupos de dos (2) orificios en la parte de
abajo del marco del panel solar. Con un destornillador Phillips y
los ocho (8) tornillos n.° para metal incluidos, fije las cuatro
ménsulas (incluidas) al marco, tal como se muestra en la
ilustración – 5.
6. SELECCIONE EL LUGAR PARA EL PANEL Y HAGA PASAR
EL CABLE
Seleccione un lugar para el panel solar con orientación hacia el sur
para lograr una exposición óptima al sol. NOTA: Evite las
ubicaciones donde haya sombra por la tarde. A continuación,
determine por dónde pasará el cable desde el panel hasta el
ventilador. NOTA: El cable se puede instalar encima del material
de revestimiento del techo. Sin embargo, si se prefiere pasar el
cable por el ático como se muestra en la ilustración 6, complete
los siguientes pasos:
x Taladre un orificio en la base del techo cerca de la parte
superior de la ubicación del panel solar, preferentemente
debajo de una teja.
x Inserte los extremos de los cables con terminaciones por el
orificio en dirección al ático. Solamente deje cable suficiente
encima del techo como para que el cable no esté tenso en el
lugar que se eligió para el panel.
x Calafatee alrededor del cable en el orificio.
Page 4 of 6
Illustration – 7 Installed Solar Panel
Ilustración – 7 Panel solar instalado
Illustration – 6 Wire Routing Option
Through Attic
Ilustración – 6 Opción de pasar el cable
por el ático
Illustration – 8 Mounting the Ventilator
Ilustración – 8 Instalación del ventilador
NOTE: If additional wire length is
needed to position the solar panel in its
optimum location use the following: UL
Listed SPT-W, 18/C Black with extruded
white stripe, UV resistant, 105ºC
(221ºF).
7. MOUNT SOLAR PANEL
Secure the solar panel to the roof using
the four (4) included #10 hex head
screws as shown in Illustration 7.
NOTE: It is important to ensure that the
fasteners used to secure the panel to
the roof fully penetrate the underside of
the roof sheathing.
8. MOUNT THE VENTILATOR TO
THE ROOF
If the wire from the solar panel is
installed on top of the roof, perform
Step 9 first by routing the wire
beneath the flange. Make sure the top
edge of the base flange parallels the
ridgeline of the roof. The embossed
arrow, with the adjacent embossed word
“UP”, should be pointing toward the
ridgeline. Slip the upper half of the
flange under the shingles as shown in
Illustration 8. Center the ventilator
over the hole. Next, attach the flange
securely to the roof using roofing nails
around the perimeter of the unit.
NOTE: Nails on the top half of the
flange should be positioned
underneath the top layers of shingles.
NOTE: Nails used to secure the unit
to the roof should be of sufficient
length to fully penetrate the underside
of the decking material.
NOTE: Be careful not to nail through
any electrical wire.
A non-hardening caulk or roofing
cement should be used as a seal
between the flange and shingles and
also to seal the exposed nail heads.
In addition, use caulk to seal around
any wiring routed beneath the flange.
9. CONNECT FAN MOTOR
WARNING: Depending on the panel’s sun exposure, it may
be likely that the fan will start spinning once the connections
are made. It is recommended that the panel be covered
temporarily while completing the installation.
Using the male and female quick connect terminations from
the panel and the motor, connect the appropriate leads as
follows:
NOTA: Si necesita más largo de cable
para colocar el panel solar en el lugar
óptimo, use lo siguiente: cable negro UL
SPT-W, 18/C con raya blanca en resalto,
resistente a los rayos UV, 105 °C (221 °F).
7. INSTALE EL PANEL SOLAR
Fije el panel solar al techo usando los
cuatro (4) tornillos hexagonales n.°10
como se muestra en la ilustración – 7.
NOTA: Es importante asegurarse de que
los tornillos usados para fijar el panel al
techo penetren completamente en la parte
de abajo de la cubierta del techo.
8. INSTALE EN VENTILADOR EN EL
TECHO
Si el cable del panel solar se instala
encima del techo, realice el Paso 9
primero pasando el cable por debajo de
la pestaña. Asegúrese de que el borde
superior de la pestaña de la base esté
paralelo a la cumbrera del techo. La
flecha en relieve, con la inscripción “UP”,
debe estar apuntando hacia la cumbrera
del techo. Deslice la mitad superior de la
pestaña debajo de las tejas como se
muestra en la ilustración – 8. Centre el
ventilador sobre el orificio. A
continuación, fije la pestaña firmemente al
techo usando clavos para techar alrededor
del perímetro de la unidad.
NOTA: Los clavos en la mitad superior de
la pestaña deben colocarse debajo de las
capas superiores de tejas.
NOTA: Los clavos usados para fijar la
unidad al techo deben ser lo
suficientemente largos como para
penetrar completamente la parte de abajo
del material de revestimiento.
NOTA: Tenga cuidado de no clavar un
clavo en un cable de electricidad.
Se debe usar un calafate que no se
endurezca o cemento de techado como
sellador entre la pestaña y las tejas y para
sellar también las cabezas expuestas de
los clavos.
Además, use calafate para sellar
alrededor de todo cable que se haya
pasado debajo de la pestaña.
9. CONECTE EL MOTOR DEL VENTILADOR
ADVERTENCIA: Según la exposición solar que tenga el panel, es
posible que el ventilador comience a girar una vez hechas las
conexiones. Se recomienda cubrir temporalmente el panel
mientras se completa la instalación.
Usando las terminaciones de conexión rápida macho y hembra del
panel y del motor, conecte los cables de la siguiente manera:
Page 5 of 6
Illustration – 9 Wiring Connections
Ilustración – 9 Conexiones de cables
x Connect the ribbed wire “+”
from the panel to the white wire
“+” from the motor.
x Connect the smooth wire “-”
from the panel to the black wire
“-” from the motor.
Refer to Illustration – 9.
x Conecte el cable estriado “+”
del panel al cable blanco “+”
del motor.
x Conecte el cable liso “-” del
panel al cable negro “-” del
motor.
Vea la ilustración – 9.
Five-Year Limited Warranty
Limited, Non-prorated and Transferable
Who and What Is Covered and For How Long
Provided that the product covered by this warranty have
been installed in strict accordance with the Air Vent written
installation instructions and in accordance with all local codes
and standards, including those pertaining to fire rated
construction, Air Vent warrants to the original purchaser or the
subsequent owner of the property that the parts described in
the following sentence are free from manufacturing defects for
5 (five) years from the date of purchase. This warranty
covers the fan blade, motor and solar panel.
Should any defect occur during the 5 (five) year period
following the date of purchase, Air Vent will provide a
replacement for that part deemed to be defective (but not
including the labor costs incurred in removing the part or
installing the replacement part).
In the event of replacement according to the terms of this
warranty, the original warranty shall apply to the replacement
part and will extend for the balance of the warranty period in
effect at the time the part proved defective.
Replacement Plus
TM
Protection
The Air Vent product to which this warranty applies is
covered by Replacement Plus Protection for a period of 2
(two) years, provided that the product has been installed in
strict accordance with Air Vent’s written installation
instructions and in accordance with all local codes and
standards, including those pertaining to fire-rated
construction. Under this warranty feature, Air Vent, at no
charge, will replace any part covered by this warranty and
found to be defective during the Replacement Plus period (the
Replacement Plus period begins when installation is
completed). Air Vent’s maximum liability under Replacement
Plus will be equal to the reasonable cost of the replacement
part, including labor to remove the defective part and install
the replacement part.
In instances in which Air Vent, according to the terms of this
warranty, has agreed to pay the cost of labor required to
replace a defective part, Air Vent will provide reimbursement
only upon receipt of a copy of the contractor’s invoice or other
written evidence of the completion of the work which Air Vent,
at its sole discretion, deems acceptable.
Garantía limitada de cinco años
Limitada, no prorrateada y transferible
Cobertura y duración
Siempre que el producto cubierto por esta garantía se haya
instalado estrictamente de conformidad con las instrucciones
escritas de instalación de Air Vent y conforme a todos los
códigos y normas locales, incluidos aquellos relativos a la
construcción de clasificación ignífuga, Air Vent garantiza al
comprador original o al propietario subsiguiente del bien que las
piezas descritas en la siguiente oración estarán libres de
defectos de fabricación durante 5 (cinco) años a partir de la
fecha de compra. Esta garantía cubre las aspas del ventilador,
el motor y el panel solar.
En caso de que se produzca cualquier defecto durante el
período de 5 (cinco) años siguientes a la fecha de compra, Air
Vent reemplazará la pieza considerada defectuosa (sin incluir
los costos de mano de obra incurridos para extraer la pieza o
instalar la pieza de reemplazo).
En caso de que se realice un reemplazo conforme a los
términos de esta garantía, la garantía original se aplicará a la
pieza de reemplazo y se extenderá durante el resto del período
de garantía en vigencia al momento en que la pieza haya
resultado defectuosa.
Protección Replacement Plus
TM
El producto Air Vent al cual se aplica esta garantía está
cubierto por la protección Replacement Plus por un período de
2 (dos) años, siempre que el producto se haya instalado
estrictamente de conformidad con las instrucciones escritas de
instalación de Air Vent y conforme a todos los códigos y normas
locales, incluidos aquellos relativos a la construcción de
clasificación ignífuga. Conforme a esta característica de la
garantía, Air Vent reemplazará sin cargo toda pieza cubierta por
esta garantía que resulte defectuosa durante el período
cubierto por la protección Replacement Plus (dicho período
comienza cuando se completa la instalación). Conforme a
Replacement Plus, la xima responsabilidad de Air Vent será
equivalente al costo razonable de la pieza de reemplazo,
incluida la mano de obra para extraer la pieza defectuosa e
instalar la de repuesto.
En los casos en que, conforme a los términos de esta
garantía, Air Vent haya acordado pagar el costo de la mano de
obra requerida para reemplazar una pieza defectuosa, la
empresa sólo proveerá el reembolso al recibir una copia de la
factura del contratista u otra evidencia escrita de la finalización
del trabajo que Air Vent, a su exclusivo criterio, considere
aceptable.
4117 Pinnacle Point Drive
Suite 400
Dallas, Texas 75211
www.airvent.com
1-800-527-1924
©2009 Air Vent, Inc.
June 2009
6fo6egaP
Transferability
If there is a change in ownership, the warranty may be
transferred by the original purchaser of the solar power vent to
the new owner under the terms and conditions of this warranty.
The warranty will then cover the period of 5 (five) years following
the purchase of the vent. If the warranty is transferred from the
original purchaser to a new owner during the 2 (two) year
Replacement Plus period, the remaining period of Replacement
Plus Protection will be available to the subsequent property
owner.
At the end of the Replacement Plus Protection period, the
warranty will cover 3 (three) years following the purchase of the
power vent.
Limitations
Air Vent shall not be liable for, and this warranty does not apply
to, any failure, defect or damage resulting from or connected with
misuse, abuse, neglect or improper handling or storage, or
installation not in strict adherence to Air Vent’s written
instructions. Air Vent reserves the right to discontinue or modify
any of its products, including color, and shall not be liable as a
result of such discontinuance or modification. If Air Vent replaces
any part under this warranty, it may substitute parts designated
by Air Vent to be of comparable quality or price range in the
event the product initially installed has been discontinued or
modified.
Other Conditions
This warranty is expressly in lieu of all other oral or written
warranties, liabilities or obligations of Air Vent. Pertinent state
law shall control for what period of time subsequent to sale a
consumer/homeowner may seek a remedy pursuant to the
implied warranty of merchantability or fitness for a particular
purpose. In no event shall Air Vent be liable for consequential or
incidental damages of any kind, including any damage to the
building, its contents or any persons therein, resulting from the
breach of warranty set forth herein. No field representative of Air
Vent or any distributor or dealer is authorized to make any
change or modification to this warranty. Some states do not
allow limitations on or the exclusion of incidental or consequential
damages, so the above exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also
have other rights that vary from state to state.
What the Customer Must Do
If you believe any part is defective, call 1-800-527-1924 for
Customer Service. If it’s determined that parts need to be
returned to Air Vent they must be shipped freight prepaid to Air
Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, Texas 75211.
Air Vent shall then promptly inspect the claimed defect before the
furnishing of any replacement part is approved, and Air Vent
shall, within a reasonable time after approval, provide the
replacement part under the terms of the warranty. This warranty
is effective on all solar power vents installed on or after January
1, 2007.
Capacidad de transferencia
En caso de cambio de propiedad, el comprador original del
ventilador a energía solar podrá transferir la garantía al nuevo
propietario, conforme a los términos y condiciones de la misma. La
garantía cubrirá entonces el período de 5 (cinco) años a partir de la
compra del producto. Si la garantía fuera transferida por el
comprador original a un nuevo propietario durante el período
Replacement Plus de 2 (dos) años, el período restante de la
protección Replacement Plus estará a disposición del propietario
subsiguiente. Al finalizar dicho período de protección, la garantía
cubrirá 3 (tres) años a partir de la compra del producto.
Limitaciones
Air Vent no será responsable y esta garantía no se aplicará en
caso de fallas, defectos o daños resultantes de o relacionados con
el uso indebido, abuso, negligencia o manejo o almacenamiento
incorrectos, como tampoco en el caso de una instalación que no
haya cumplido estrictamente las instrucciones escritas de Air Vent.
Air Vent se reserva el derecho de suspender o modificar cualquiera
de sus productos, incluyendo el color, y no será responsable como
resultado de dicha suspensión o modificación. En caso de que Air
Vent reemplace una pieza conforme a esta garantía, podrá utilizar
otra que considere de calidad o nivel de precio comparables si el
producto inicialmente instalado hubiera sido suspendido o
modificado.
Otras condiciones
Esta garantía reemplaza expresamente toda otra garantía,
responsabilidad u obligación verbal o escrita de Air Vent. La
legislación del estado pertinente regirá el plazo subsiguiente a la
venta en que un consumidor/propietario de vivienda podrá tratar de
obtener un recurso, de conformidad con la garantía implícita de
comerciabilidad o aptitud para un propósito particular. En ningún
caso Air Vent será responsable de los daños consecuentes o
incidentales de cualquier naturaleza (incluido cualquier daño al
edificio, a su contenido o a los ocupantes del mismo) resultantes
del incumplimiento de una garantía establecida en el presente.
Ningún representante de campo, distribuidor o agente de Air Vent
está autorizado a realizar cambio o modificación alguna a esta
garantía. Algunos estados no permiten limitar o excluir los daños
incidentales o consecuentes, por lo cual es posible que las
exclusiones mencionadas precedentemente no se apliquen a su
caso.
Esta garantía le otorga derechos legales específicos, y es
posible que usted también disponga de otros derechos que varían
de estado a estado.
Qué debe hacer el consumidor
Si usted considera que una pieza está defectuosa, llame al
1-800-527-1924 para obtener Servicio al Cliente. En caso de que se
determine que las piezas deben devolverse a Air Vent, éstas
deberán despacharse con flete pagado anticipadamente a Air Vent,
4117 Pinnacle Point Drive, Suite 400, Dallas, Texas 75211. Antes de
aprobar el suministro de una pieza de reemplazo, Air Vent procederá
a inspeccionar a la brevedad el defecto objeto del reclamo. En un
plazo razonable después de la aprobación, Air Vent proveerá la
pieza de reemplazo conforme a los términos de la garantía. Esta
garantía es válida para todos los ventiladores a energía solar
instalados a partir del 1 de enero de 2007.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Air Vent NPSG8 Instrucciones de operación

Tipo
Instrucciones de operación
Este manual también es adecuado para

En otros idiomas