Air Vent SC8BL Instrucciones de operación

Tipo
Instrucciones de operación
Part No. 18382
Installation Instructions
Use this unit only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Utilice esta unidad solamente de la manera indicada por el
fabricante. Si tiene alguna duda, contacte al fabricante.
Roof-Mounted Solar Attic Ventilator
Ventilador de ático a energía solar, de montaje en techo
Model SC8BL
Modelo SC8BL
Important Safety Information
Información importante de seguridad
IMPORTANT: Read all warning messages and instructions
before starting installation of this fan. Failure to follow these
safety instructions can result in injury or even death. If you need
assistance in understanding these instructions or have questions
or commen
ts, please call 309-692-6969.
ELECTRICAL HAZARD
DANGER: Watch out for existing electrical wiring and other utility
wires or pipes when selecting a location for the fan. Do not install
the fan where there is electrical wiring in the way. Select another
location or have a qualified electrician move the wiring to a
different location.
LACERATION HAZARDS
DANGER: This fan has an unguarded fan blade. Do not use in
locations which are readily accessible to people or animals. Do
not let children play in an attic where this fan has been installed.
Contact with this fan while in operation can
result in injury or even
death.
DANGER: Keep the solar panel covered by its protective
packing until the fan is mounted or at anytime the motor or
fan blade are being serviced. This fan is controlled by a solar
panel it may start at any time the solar panel is exposed to
sunlight. Contact with the fan blades while the fan is operating
can result in serious injury.
WARNING: This product has sharp metal edges that can cut
your hands. Wear canvas work gloves while handling the fan
during installation.
CARBON MONOXIDE HAZARDS
DAN
GER: Carbon monoxide is a colorless, odorless gas that
can kill. Carbon monoxide may be drawn into the house by the
operation of this fan if your fuel-burning equipment is not properly
maintained and vented or if you lack adequate attic venting.
You should check the flue of your hot water heater and furnace to
see that the pipes are intact and sealed. Request an inspection
from your fuel supplier (gas company or heating oil company) or
from a municipal building inspector if you have any questions
about the safety of your fuel-burning equipment.
OTHER HAZARDS
DANGER: For general ventilating use
only. Do not use to
exhaust hazardous or explosive materials or vapors. Use of this
fan to exhaust hazardous, explosive or flammable materials may
result in a fire or explosion, causing injury or death.
You must also check the number and size of your intake vents. A
total of at least 2.7 square feet of unobstructed intake venting in
the soffit or under-eaves must be available for safe operation of
this ventilator. If you have less than the amount specified above,
STOP and install additional vents before proceeding.
IMPORTANTE: Antes de comenzar a instalar este ventilador, lea todos los
mensajes de advertencia y las instrucciones. El no seguir estas
instrucciones d
e seguridad puede causar lesiones o incluso la muerte. Si
necesita asistencia para comprender estas instrucciones o desea hacer
preguntas o comentarios, llame al 309-692-6969.
RIESGO ELÉCTRICO
PELIGRO: Cuando elija un lugar para el ventilador, preste atención a la
existencia de cableado eléctrico y otros cables o tubos de servicio. No
instale el ventilador donde exista cableado eléctrico. Seleccione otro lugar
o solicite a un electricista especializado que traslade el cableado a otra
ubicación.
RIESGO DE LACERACIONES
PELIGRO: Este ventilador tiene aspas no protegidas. No lo utilice en
lugares fácilmente accesibles a personas o animales. No permita que los
niños jueguen en un ático donde se haya instalado este ventilador. El
contacto con este producto en funcionamiento puede ocasionar lesiones o
incluso la muerte.
PELIGRO: Mantenga el panel solar cubierto con su
envase protector
hasta que se instale el ventilador o cada vez que el motor o el aspa del
ventilador reciban servicio. Este ventilador es controlado por un panel
solar, por lo que puede ponerse en funcionamiento toda vez que el panel
solar esté expuesto a la luz solar. El contacto con las aspas del ventilador
mientras este está en funcionamiento puede ocasionar graves lesiones.
ADVERTENCIA: Este producto tiene bordes metálicos filosos que pueden
cortarle las manos. Mientras manipula el ventilador durante la instalación,
utilice guantes de trabajo de lona.
RIESGO DE MONÓXIDO DE CARBONO
PELIGRO: El monóxido de carbono es un gas incoloro y sin olor que puede
provocar la muerte. El funcionamiento del ventilador puede llevar este gas
al interior de la casa si el equipo que consume combustible no se mantien
e
y ventila correctamente, o si no se dispone de una ventilación adecuada en
el ático.
Es aconsejable verificar el cañón de la chimenea del calentador de agua y
el horno para garantizar que la tubería esté intacta y sellada. Si tiene
alguna pregunta sobre la seguridad del sistema de escape de sus equipos
que consumen combustible, solicite una inspección a su proveedor de
combustible (compañía de gas o de aceite combustible), o bien a un
inspector municipal de construcción.
OTROS RIESGOS
PELIGRO: Para ventilación general únicamente. No utilice el producto
para expeler materiales o vapores peligrosos o explosivos. El uso de este
ventilador para expeler materiales peligrosos, explosivos o inflamables
puede dar lugar a un incendio o una explosión y causar lesiones o la
muerte.
Tam
bién debe verificar la cantidad y el tamaño de los respiraderos de
entrada. Para que este ventilador funcione en forma segura, se requiere un
total de al menos 2.7 pies cuadrados de entrada de ventilación sin
obstrucciones en el sofito o debajo del alero. Si usted no dispone del
espacio especificado, SUSPENDA la instalación del ventilador e instale
respiraderos adicionales antes de continuar.
Page 2 of 6
Illustration – 1 Ventilator Location
Ilustración – 1 Ubicación del ventilador
Illustration – 2 Drilling Guide Hole
Ilustración – 2 Taladrado del orificio de
guía
ROOF-MOUNT SOLAR POWER VENTILATOR
INSTALLATION INSTRUCTIONS
NOTE: Air intake openings must be installed for proper
exhaust operation. Best results will be obtained if these
openings are located around the eaves. Rectangular soffit
vents or continuous soffit vents are suggested.
Sq. Ft. of Air Intake
Model
Opening Needed
SC8BL 2.7
TOOLS NEEDED:
electric drill hammer
1/2” drill bit utility knife
jig or sabre saw caulk gun
tape measure work gloves
pencil or marker safety glasses
MATERIALS NEEDED:
roofing nails (ring shank recommended)
caulk and/or roofing cement
WHAT COMES IN THE CARTON:
roof-mount fan and motor assembly
NOTE: Please do not remove/discard
protective cover for solar panel until
installation is complete.
1. SELECT VENTILATOR LOCATION
Select a location close to the ridgeline
on the backside of the house to
maximize sun exposure. The ventilator
should be installed near the center of
the roof for optimum airflow. Refer to
Illustration – 1. If installing multiple
fans, space them evenly across the
roof. From the roof, measure the
distance to the ridgeline and to one end
of the roof. Note these dimensions for
use in Step 2.
2. DETERMINE EXACT VENTILATOR
POSITION
Using the dimensions obtained on the
roof in Step 1, locate the same position
inside the attic. Select the closest
centered location between two rafters to
establish the center of the roof-mount
solar powered attic ventilator. From the
attic, drill a guide hole through the roof
at the location centered between rafters.
Refer to Illustration – 2. Place an object
through the hole for quick identification
from the roof.
INSTRUCCIONES DE INSTALACIÓN DEL VENTILADOR A
ENERGÍA SOLAR DE MONTAJE EN EL TECHO
NOTA: Deben instalarse aberturas de toma de aire para el
correcto funcionamiento del ventilador. Los mejores resultados se
logran si estas aberturas se encuentran alrededor del alero. Se
sugieren respiraderos rectangulares o continuos en el sofito.
Pies cuadrados de abertura necesaria
Modelo
para toma de aire
SC8BL 2.7
HERRAMIENTAS NECESARIAS:
taladro eléctrico martillo
broca de taladro de 1/2 pulg. cuchillo utilitario
sierra de vaivén o caladora pistola calafateadora
cinta métrica guantes de trabajo
lápiz o marcador anteojos de protección
MATERIALES NECESARIOS:
clavos para techo (se recomienda de cuerpo estriado)
calafate o cemento para techar
CONTENIDO DE LA CAJA:
ventilador de techo y conjunto del motor
NOTA: No quite ni deseche el protector
del panel solar hasta que finalice la
instalación.
1. SELECCIONE EL LUGAR DEL
VENTILADOR
Seleccione un lugar cerca del caballete en
la parte trasera de la casa para maximizar
la exposición solar. El ventilador debe
instalarse cerca del centro del techo para
lograr un flujo de aire óptimo. Vea la
ilustración – 1. Si va a instalar varios
ventiladores, distribúyalos de manera
uniforme a lo ancho del techo. Desde el
techo, mida la distancia hasta la cumbrera
y hasta un extremo del techo. Anote estas
dimensiones para usarlas en el Paso 2.
2. DETERMINE LA POSICIÓN EXACTA
DEL VENTILADOR
Usando las dimensiones obtenidas en el
techo en el Paso 1, ubique la misma
posición dentro del ático. Seleccione el
lugar más cerca del centro entre dos vigas
para establecer el centro del ventilador de
ático a energía solar de montaje en el
techo. Desde el ático, taladre un orificio
de guía a través del techo en el lugar
centrado entre dos vigas. Vea la
ilustración – 2. Pase algún objeto por el
orificio para poder ubicarlo fácilmente
desde el techo.
Page 3 of 6
Illustration – 3 Hole in Roof for Ventilator
Ilustración – 3 Orificio en el techo para
el ventilador
Illustration – 4 Trimming Roof Covering
Materials
Ilustración – 4 Recorte de los materiales
de revestimiento del techo
Illustration – 6 Mounting the Ventilator
Ilustración – 6 Instalación del ventilador
Illustration – 5 Wiring Connections
Ilustración – 5 Conexiones de cables
3. MARK AND CUT HOLE IN ROOF
From the roof, draw a 14-1/2” diameter
circle centered on the guide hole
created in Step 2 using the template on
the carton. Cut and remove all roof
shingles (and deck) inside the 14-1/2”
diameter circle using a jig or sabre saw.
Refer to Illustration – 3. NOTE: Do not
cut through any rafters. Cutting a rafter
may jeopardize the structural integrity of
the roof.
4. TRIM ROOF COVERING
MATERIALS
Using a utility knife, cut an extra 1” off
the top half of the hole (shingles only) to
allow room for placing and positioning
the flange. Refer to Illustration – 4.
5. CONNECT FAN MOTOR
WARNING: Depending on the panel’s
sun exposure, it may be likely that the
fan will start spinning once the
connections are made. To avoid
possible harm, it is recommended that
the solar panel’s protective covering be
left in place until the installation is
complete.
Using the male and female quick
connect terminations from the panel and
the motor, connect the appropriate
leads as follows:
Connect the ribbed wire “+”
from the panel to the white wire
“+” from the motor.
Connect the smooth wire “-”
from the panel to the black wire
“-” from the motor.
Refer to Illustration – 5.
6. MOUNT THE VENTILATOR TO
THE ROOF
Make sure the top edge of the base
flange parallels the ridgeline of the roof.
The embossed arrow, with the adjacent
embossed word “UP”, should be
pointing toward the ridgeline. Slip the
upper half of the flange under the
shingles as shown in Illustration – 6.
Center the ventilator over the hole.
Next, attach the flange securely to the
roof using roofing nails around the
perimeter of the unit.
3. MARQUE Y CORTE UN ORIFICIO EN
EL TECHO
Desde el techo, trace un círculo de 14-1/2
pulg. de diámetro centrado en el orificio de
guía creado en el Paso 2 usando la
plantilla que viene en la caja. Corte y
retire todas las tejas del techo (y el
revestimiento) dentro del círculo de 14-1/2
pulg. de diámetro usando una sierra de
vaivén o caladora. Vea la ilustración – 3.
NOTA: Tenga cuidado de no cortar
ninguna viga. Si corta una viga podría
poner en juego la integridad estructural del
techo.
4. RECORTE LOS MATERIALES DE
REVESTIMIENTO DEL TECHO
Con un cuchillo de utilería, corte una
pulgada extra de la parte superior del
orificio (solamente las tejas) para hacer
lugar para colocar y ubicar la pestaña.
Vea la ilustración – 4.
5. CONECTE EL MOTOR DEL
VENTILADOR
ADVERTENCIA: Según la exposición
solar que tenga el panel, es posible que el
ventilador comience a girar una vez
hechas las conexiones. Para evitar un
posible daño, se recomienda dejar el
protector del panel solar en su lugar hasta
que finalice la instalación.
Usando las terminaciones de conexión
rápida macho y hembra del panel y del
motor, conecte los cables de la siguiente
manera:
Conecte el cable estriado “+” del
panel al cable blanco “+” del
motor.
Conecte el cable liso “-” del panel
al cable negro “-” del motor.
Vea la ilustración – 5.
6. INSTALE EN VENTILADOR EN EL
TECHO
Asegúrese de que el borde superior de la
pestaña de la base esté paralelo a la
cumbrera del techo. La flecha en relieve,
con la inscripción “UP”, debe estar
apuntando hacia la cumbrera del techo.
Deslice la mitad superior de la pestaña
debajo de las tejas como se muestra en la
ilustración – 6. Centre el ventilador sobre
el orificio. A continuación, fije la pestaña
firmemente al techo usando clavos para
techar alrededor del perímetro de la
unidad.
Page 4 of 6
Illustration – 7 Adjust the Solar Panel
Ilustración – 7 Ajuste el panel solar
NOTE: Nails on the top half of the flange should be
positioned underneath the top layers of shingles.
NOTE: Nails used to secure the unit to the roof should be of
sufficient length to fully penetrate the underside of the decking
material.
A non-hardening caulk or roofing cement should be used as a
seal between the flange and shingles and also to seal the
exposed nail heads.
7. ADJUST THE SOLAR PANEL
Tilt and/or rotate the solar panel in the
direction that maximizes the sun
exposure as shown in Illustration – 7.
The optimum tilt angle (toward the
South) can be calculated by using the
site latitude plus 20 degrees. The
resultant angle should be used to
position the panel from the horizontal
position (panel facing directly vertical)
toward the South. NOTE: The resultant
angle may include the roof pitch
depending on the orientation of the
structure.
To tilt the solar panel, loosen the two (2)
wing nuts that connect the arms of the bracket assembly to
the frame of the solar panel. Lift the panel up to the
appropriate tilt angle, then tighten the two (2) wing nuts to
secure the solar panel in place.
To rotate the solar panel, loosen the three (3) wing nuts that
secure the solar panel and bracket assembly to the top of the
dome (located beneath the solar panel). Rotate the solar
panel and bracket assembly to the optimal orientation, then
tighten the three (3) wing nuts to secure the bracket in place.
NOTE: Optimal exposure may require that the panel and
tilting bracket be removed from the dome and positioned at a
different location on the structure.
NOTE: If additional wire length is needed to position the solar
panel in its optimum location use the following: UL Listed SPT-
W, 18/C Black with extruded white stripe, UV resistant, 105ºC
(221ºF).
8. REMOVE SOLAR PANEL PROTECTIVE COVER
Carefully remove the protective cover from the solar panel to
cool the attic with the new solar powered attic ventilator.
NOTA: Los clavos en la mitad superior de la pestaña deben
colocarse debajo de las capas superiores de tejas.
NOTA: Los clavos usados para fijar la unidad al techo deben ser lo
suficientemente largos como para penetrar completamente la parte
de abajo del material de revestimiento.
Se debe usar un calafate que no se endurezca o cemento de
techado como sellador entre la pestaña y las tejas y para sellar
también las cabezas expuestas de los clavos.
7. AJUSTE EL PANEL SOLAR
Incline o rote el panel solar en la dirección
que maximice la exposición solar, como lo
indica la ilustración – 7. El ángulo de
inclinación óptimo (hacia el sur) se puede
calcular mediante el uso de la latitud del
lugar más 20 grados. El ángulo resultante
se debe usar para colocar el panel de la
posición horizontal (el panel en dirección
vertical directa) hacia el sur. NOTA: Es
posible que el ángulo resultante incluya la
pendiente del techo, según la orientación
de la estructura.
Para inclinar el panel solar, afloje las dos
(2) tuercas mariposa que unen los brazos
del conjunto de soporte a la estructura del
panel solar. Incline el panel hacia arriba
hasta colocarlo en el ángulo de inclinación adecuado, luego ajuste
las dos (2) tuercas mariposa para sujetar el panel solar en el lugar.
Para rotar el panel solar, afloje las tres (3) tuercas mariposa que
sujetan el panel solar y el conjunto de soporte a la parte superior
de la cúpula (ubicada debajo del panel solar). Rote el panel solar y
el conjunto de soporte hacia la orientación óptima, luego ajuste las
tres (3) tuercas mariposa para sujetar el soporte en el lugar.
NOTA: Para lograr la exposición óptima, es posible que deba
quitar el panel y el soporte de inclinación de la cúpula y colocarlos
en otro lugar de la estructura.
NOTA: Si necesita más largo de cable para colocar el panel solar
en el lugar óptimo, use lo siguiente: cable negro UL SPT-W, 18/C
con raya blanca en resalto, resistente a los rayos UV, 105 °C (221
°F).
8. QUITE EL PROTECTOR DEL PANEL SOLAR
Retire cuidadosamente el protector del panel solar para refrigerar
el ático con el nuevo ventilador de ático a energía solar.
Page 5 of 6
Five-Year Limited Warranty
Limited, Non-prorated and Transferable
Who and What Is Covered and For How Long
Provided that the product covered by this warranty has
been installed in strict accordance with the Air Vent written
installation instructions and in accordance with all local codes
and standards, including those pertaining to fire rated
construction, Air Vent warrants to the original purchaser or the
subsequent owner of the property that the parts described in
the following sentence are free from manufacturing defects for
5 (five) years from the date of purchase. This warranty
covers the fan blade, motor and solar panel.
Should any defect occur during the 5 (five) year period
following the date of purchase, Air Vent will provide a
replacement for that part deemed to be defective (but not
including the labor costs incurred in removing the part or
installing the replacement part).
In the event of replacement according to the terms of this
warranty, the original warranty shall apply to the replacement
part and will extend for the balance of the warranty period in
effect at the time the part proved defective.
Replacement Plus
TM
Protection
The Air Vent product to which this warranty applies is
covered by Replacement Plus Protection for a period of 2
(two) years, provided that the product has been installed in
strict accordance with Air Vent’s written installation
instructions and in accordance with all local codes and
standards, including those pertaining to fire-rated
construction. Under this warranty feature, Air Vent, at no
charge, will replace any part covered by this warranty and
found to be defective during the Replacement Plus period (the
Replacement Plus period begins when installation is
completed). Air Vent’s maximum liability under Replacement
Plus will be equal to the reasonable cost of the replacement
part, including labor to remove the defective part and install
the replacement part.
In instances in which Air Vent, according to the terms of this
warranty, has agreed to pay the cost of labor required to
replace a defective part, Air Vent will provide reimbursement
only upon receipt of a copy of the contractor’s invoice or other
written evidence of the completion of the work which Air Vent,
at its sole discretion, deems acceptable.
Transferability
If there is a change in ownership, the warranty may be
transferred by the original purchaser of the solar power vent
to the new owner under the terms and conditions of this
warranty. The warranty will then cover the period of 5 (five)
years following the purchase of the vent. If the warranty is
transferred from the original purchaser to a new owner during
the 2 (two) year Replacement Plus period, the remaining
period of Replacement Plus Protection will be available to the
subsequent property owner. At the end of the Replacement
Plus Protection period, the warranty will cover 3 (three) years
following the purchase of the power vent.
Garantía limitada de cinco años
Limitada, no prorrateada y transferible
Cobertura y duración
Siempre que el producto cubierto por esta garantía se haya
instalado estrictamente de conformidad con las instrucciones
escritas de instalación de Air Vent y conforme a todos los
códigos y normas locales, incluidos aquellos relativos a la
construcción de clasificación ignífuga, Air Vent garantiza al
comprador original o al propietario subsiguiente del bien que las
piezas descritas en la siguiente oración estarán libres de
defectos de fabricación durante 5 (cinco) años a partir de la
fecha de compra. Esta garantía cubre las aspas del ventilador,
el motor y el panel solar.
En caso de que se produzca cualquier defecto durante el
período de 5 (cinco) años siguientes a la fecha de compra, Air
Vent reemplazará la pieza considerada defectuosa (sin incluir
los costos de mano de obra incurridos para extraer la pieza o
instalar la pieza de reemplazo).
En caso de que se realice un reemplazo conforme a los
términos de esta garantía, la garantía original se aplicará a la
pieza de reemplazo y se extenderá durante el resto del período
de garantía en vigencia al momento en que la pieza haya
resultado defectuosa.
Protección Replacement Plus
TM
El producto Air Vent al cual se aplica esta garantía está
cubierto por la protección Replacement Plus por un período de
2 (dos) años, siempre que el producto se haya instalado
estrictamente de conformidad con las instrucciones escritas de
instalación de Air Vent y conforme a todos los códigos y normas
locales, incluidos aquellos relativos a la construcción de
clasificación ignífuga. Conforme a esta característica de la
garantía, Air Vent reemplazará sin cargo toda pieza cubierta por
esta garantía que resulte defectuosa durante el período
cubierto por la protección Replacement Plus (dicho período
comienza cuando se completa la instalación). Conforme a
Replacement Plus, la máxima responsabilidad de Air Vent será
equivalente al costo razonable de la pieza de reemplazo,
incluida la mano de obra para extraer la pieza defectuosa e
instalar la de repuesto.
En los casos en que, conforme a los términos de esta
garantía, Air Vent haya acordado pagar el costo de la mano de
obra requerida para reemplazar una pieza defectuosa, la
empresa sólo proveerá el reembolso al recibir una copia de la
factura del contratista u otra evidencia escrita de la finalización
del trabajo que Air Vent, a su exclusivo criterio, considere
aceptable.
Capacidad de transferencia
En caso de cambio de propiedad, el comprador original del
ventilador a energía solar podrá transferir la garantía al nuevo
propietario, conforme a los términos y condiciones de la misma.
La garantía cubrirá entonces el período de 5 (cinco) años a
partir de la compra del producto. Si la garantía fuera transferida
por el comprador original a un nuevo propietario durante el
período Replacement Plus de 2 (dos) años, el período restante
de la protección Replacement Plus estará a disposición del
propietario subsiguiente. Al finalizar dicho período de
protección, la garantía cubrirá 3 (tres) años a partir de la
compra del producto.
Page 6 of 6
Limitations
Air Vent shall not be liable for, and this warranty does not
apply to, any failure, defect or damage resulting from or
connected with misuse, abuse, neglect or improper handling
or storage, or installation not in strict adherence to Air Vent’s
written instructions. Air Vent reserves the right to discontinue
or modify any of its products, including color, and shall not be
liable as a result of such discontinuance or modification. If Air
Vent replaces any part under this warranty, it may substitute
parts designated by Air Vent to be of comparable quality or
price range in the event the product initially installed has been
discontinued or modified.
Other Conditions
This warranty is expressly in lieu of all other oral or written
warranties, liabilities or obligations of Air Vent. Pertinent state
law shall control for what period of time subsequent to sale a
consumer/homeowner may seek a remedy pursuant to the
implied warranty of merchantability or fitness for a particular
purpose. In no event shall Air Vent be liable for consequential
or incidental damages of any kind, including any damage to
the building, its contents or any persons therein, resulting
from the breach of warranty set forth herein. No field
representative of Air Vent or any distributor or dealer is
authorized to make any change or modification to this
warranty. Some states do not allow limitations on or the
exclusion of incidental or consequential damages, so the
above exclusions may not apply to you.
This warranty gives you specific legal rights, and you may
also have other rights that vary from state to state.
What the Customer Must Do
If you believe any part is defective, call 1-800-527-1924 for
Customer Service. If it’s determined that parts need to be
returned to Air Vent they must be shipped freight prepaid to
Air Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, Texas
75211. Air Vent shall then promptly inspect the claimed
defect before the furnishing of any replacement part is
approved, and Air Vent shall, within a reasonable time after
approval, provide the replacement part under the terms of the
warranty. This warranty is effective on all solar power vents
installed on or after June 1, 2007.
Limitaciones
Air Vent no será responsable y esta garantía no se aplicará
en caso de fallas, defectos o daños resultantes de o
relacionados con el uso indebido, abuso, negligencia o manejo
o almacenamiento incorrectos, como tampoco en el caso de
una instalación que no haya cumplido estrictamente las
instrucciones escritas de Air Vent. Air Vent se reserva el
derecho de suspender o modificar cualquiera de sus productos,
incluyendo el color, y no será responsable como resultado de
dicha suspensión o modificación. En caso de que Air Vent
reemplace una pieza conforme a esta garantía, podrá utilizar
otra que considere de calidad o nivel de precio comparables si
el producto inicialmente instalado hubiera sido suspendido o
modificado.
Otras condiciones
Esta garantía reemplaza expresamente toda otra garantía,
responsabilidad u obligación verbal o escrita de Air Vent. La
legislación del estado pertinente regirá el plazo subsiguiente a
la venta en que un consumidor/propietario de vivienda podrá
tratar de obtener un recurso, de conformidad con la garantía
implícita de comerciabilidad o aptitud para un propósito
particular. En ningún caso Air Vent será responsable de los
daños consecuentes o incidentales de cualquier naturaleza
(incluido cualquier daño al edificio, a su contenido o a los
ocupantes del mismo) resultantes del incumplimiento de una
garantía establecida en el presente. Ningún representante de
campo, distribuidor o agente de Air Vent está autorizado a
realizar cambio o modificación alguna a esta garantía. Algunos
estados no permiten limitar o excluir los daños incidentales o
consecuentes, por lo cual es posible que las exclusiones
mencionadas precedentemente no se apliquen a su caso.
Esta garantía le otorga derechos legales específicos, y es
posible que usted también disponga de otros derechos que
varían de estado a estado.
Qué debe hacer el consumidor
Si usted considera que una pieza está defectuosa, llame al 1-
800-527-1924 para obtener Servicio al Cliente. En caso de que
se determine que las piezas deben devolverse a Air Vent, éstas
deberán despacharse con flete pagado anticipadamente a Air
Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, Texas
75211. Antes de aprobar el suministro de una pieza de
reemplazo, Air Vent procederá a inspeccionar a la brevedad el
defecto objeto del reclamo. En un plazo razonable después de
la aprobación, Air Vent proveerá la pieza de reemplazo
conforme a los términos de la garantía. Esta garantía es válida
para todos los ventiladores a energía solar instalados a partir
del 1 de junio de 2007.
Air Vent Inc.
4117 Pinnacle Point Drive
Suite 400
Dallas, Texas 75211
© 2007 Air Vent, Inc.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Air Vent SC8BL Instrucciones de operación

Tipo
Instrucciones de operación

En otros idiomas