• Connect the pump DIRECTLY to a properly grounded, 115V GFCI outlet and
never use an extension cord to power this pump
• Pull plug before servicing this pump
• This pump has not been tested or approved for use in swimming pools or in
salt-water marine areas
• Do not pump flammable or explosive liquids, pump water only with this pump
• To reduce risk of electrical shock, fully read, follow and save the operating and
installation instructions before attempting to install or operate this pump
• Do not run this pump dry
NOTICE: Do not handle pump with wet hands or when standing on a wet surface,
or in water
• Pump will be EXTREMELY LOUD when water is no longer pumped.
UNPLUG IMMEDIATELY
• This pump is not waterproofed. Do not submerge in any liquid
• Conecte la bomba DIRECTAMENTE a una toma de tierra, nunca utilice un cable de
extensión para proporcionar alimentación a la bomba
• Desconecte la bomba antes de cualquier clase de mantenimiento
• Esta bomba no se ha puesto a prueba y no ha sido aprobada para uso en piscinas
o en áreas de agua salada
• No bombee líquidos inflamables o explosivos, bombee solamente agua con esta
bomba
• Para reducir el riesgo de descarga eléctrica, lea totalmente, siga y guarde las
instrucciones de uso e instalación antes de intentar instalar o utilizar la bomba
• No haga funcionar esta bomba en seco
AVISO: No maneje la bomba con las manos mojadas o estando en agua o en la
superficie mojada
• La bomba resultar demasiado alto cuando el agua ya no se bombea.
Desenchufe inmediatamente
• Esta bomba no está impermeabilizado. No lo sumerja en ningún líquido.
MADE IN CHINA HECHO EN CHINA
ADVERTENCIA
WARNING
SKU:1000 000 000 MODEL:ZE00802A SKU:1000 000 000 MODELO:ZE00802A
60*35mm
warning
warning
pump lable
You MUST use this suction strainer when using this pump. Push
the clear hose into the rubber connection on the strainer. Failure
to use this strainer WILL VOID WARRANTY!
Place the strainer in at least 1/2 in. of water at the lowest point
to be pumped.
Debe utilizar este filtro de succión cuando se utiliza esta bomba.
Empuje la manguera transparente en la conexión de goma en el
colador. Si no se utiliza este filtro ANULARÁ LA GARANTÍA!
Coloque el colador en al menos un medio en. De agua en el
punto más bajo a bombear.
This base will help prevent the pump from
tipping over. DO NOT REMOVE!
Esta base le ayudará a prevenir que la bomba
de inflexión sobre. NO QUITE!
47mm*22mm
OUT
IN
42*42mm
WARNING/ADVERTENCIA
WARNING/ADVERTENCIA
Debe adjuntar suministrado
manguera transparente en ENTRADA.
La bomba debe ser desconectado
cuando el agua se ha ido.
You MUST
attach supplied clear
hose onto INLET.
Pump must be unplugged
when water is gone.
108*35mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Non-Submersible Transfer Pump
115V 60Hz 1/10HP 1.8Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1001 093 976
Model ZE00802A
No sumergible Bomba de transferencia
• This pump is used for clean water only.
This pump is not waterproofed. Do not submerge in any liquid.
To increase impeller life, wet the impeller or fill out the inlet
with water before connecting garden hoses.
• Esta bomba se utiliza sólo agua limpia.
• Esta bomba no está impermeabilizado. No lo sumerja
en ningún líquido.
• Para aumentar la vida del impulsor, mojar el impulsor o
llene la entrada con agua antes de conectar las
mangueras de jardín.
WARNING/ADVERTENCIA
Bomba de transferencia para no sumergible
Es importante leer el manual para obtener información sobre la instalación, la operación y
la seguridad.Esta guía no complementa ni reemplaza al Manual del Propietario.
NO HAGA FUNCIONAR LA BOMBA EN SECO!
El funcionamiento en seco, se anulará la garantía y el daño de la bomba.
Guía de Referencia Rápida
NO BOBINAS!
Existan dobleces!
2. Conecte la manguera de succión transparente (se incluye) en
el colador de succión (se incluye) al empujar el extremo
roscado macho en el acoplador de goma del colador de succión.
Coloque el colador al menos 1,27 cm en el punto más bajo de
agua que sedebe bombear.
AVISO: Verifique que la conexión esté cerrada herméticamente.
Una fuga de aire puede hacer que la bomba funcione en seco.
4. Enrosque una manguera de jardín de 1,59 cm o más
grande (se vende por separado, longitud máx. de 15,24 m) en
la salida de descarga de la bomba.
AVISO: Asegúrese de que el extremo de la manguera de
salida no esté debajo del agua. Si la salida está bajo agua,
puede que la bomba no funcione.
AVISO: Nunca haga funcionar esta bomba a menos que se
fije a una base sólida.
6. Para hacerla funcionar, conecte la bomba a un tomacorriente
GFCI.
AVISO: Esta bomba puede ser muy ruidosa cuando se la enchufa.
Cuando el nivel de agua se ha reducido a aproximadamente 3,18
mm, DEBE DESCONECTAR LA BOMBA. NO LA HAGA FUNCIONAR
EN SECO. La bomba es EXTREMADAMENTE RUIDOSA cuando ha
dejado de bombear agua.
AVISO: Si no se bombea agua en 30 segundos, desconecte el cable
eléctrico y compruebe la conexión de los dos extremos de la
manguera de entrada para asegurarse de que no haya fugas de aire.
A continuación, añada agua a la entrada de nuevo y repita el
proceso.
3. Enrosque el otro extremo de la manguera de succión
transparente a la entrada de succión de la bomba.
AVISO: Asegúrese siempre de que el conector de la manguera
no esté dañado. Es necesario un sello hermético para que esta
bomba funcione.
Asegúrese de que la manguera transparente y el colador de
succión se encuentren en el agua antes de conectar la bomba.
1. Añada agua (aproximadamente 1 a 2 cucharadas) en la
entrada para mojar el impulsor de la bomba.
5. Adhiera la bomba a una base fuerte (mesa, tabla, etc.) para
evitar que se vuelque. Asegúrese de que las mangueras estén
lo más rectas posibles.
ADVERTENCIA: Esta bomba NO PUEDE estar sumergida en
agua y el motor NO PUEDE mojarse para nada. ¡Mojar el motor
podría causar electrocución, lo que podría provocar lesiones
graves o la muerte!
AVISO: No enrolle ni doble la manguera.
al menos de 1/2 "
If you have questions regarding your product or require
warranty assistance, please call our customer service
toll-free helpline
Do not return your product to the store.
Call us rst!
Contact us for assistance, we're here to help.
En contacto con nosotros para obtener ayuda, estamos aquí para ayudar.
No devuelva su proudct a la tienda.
Llámenos primero!
Si tiene alguna pregunta con respecto a su producto o
si necesita asistencia con la garantía, por favor llame
a nuestra línea de ayuda de servicio al cliente de gratis
1-844-241-5521
Let Us Help You !
Permítanos Help !

Transcripción de documentos

108*35mm 70*17mm SKU 1001 093 976 Model ZE00802A Non-Submersible Transfer Pump No sumergible Bomba de transferencia 115V 60Hz 1/10HP 1.8Amps THERMALLY PROTECTED PROTECCIÓN TÉRMICA logo Serial No./Serial No.: 000000 Date Code/Código de Fecha: 1439 WARNING/ADVERTENCIA • This pump is used for clean water only. • This pump is not waterproofed. Do not submerge in any liquid. • To increase impeller life, wet the impeller or fill out the inlet with water before connecting garden hoses. • Esta bomba se utiliza sólo agua limpia. • Esta bomba no está impermeabilizado. No lo sumerja en ningún líquido. • Para aumentar la vida del impulsor, mojar el impulsor o llene la entrada con agua antes de conectar las mangueras de jardín. name plate 42*42mm 60*35mm IN T WARNING/ADVERTENCIA U You MUST attach supplied clear hose onto INLET. Pump must be unplugged when water is gone. O You MUST use this suction strainer when using this pump. Push the clear hose into the rubber connection on the strainer. Failure to use this strainer WILL VOID WARRANTY! Place the strainer in at least 1/2 in. of water at the lowest point to be pumped. Debe utilizar este filtro de succión cuando se utiliza esta bomba. Empuje la manguera transparente en la conexión de goma en el colador. Si no se utiliza este filtro ANULARÁ LA GARANTÍA! Coloque el colador en al menos un medio en. De agua en el punto más bajo a bombear. WARNING/ADVERTENCIA Debe adjuntar suministrado manguera transparente en ENTRADA. La bomba debe ser desconectado cuando el agua se ha ido. warning 47mm*22mm This base will help prevent the pump from tipping over. DO NOT REMOVE! Esta base le ayudará a prevenir que la bomba de inflexión sobre. NO QUITE! warning pump lable 210*60mm WARNING SKU:1000 000 000 MODEL:ZE00802A • Connect the pump DIRECTLY to a properly grounded, 115V GFCI outlet and never use an extension cord to power this pump • Pull plug before servicing this pump • This pump has not been tested or approved for use in swimming pools or in salt-water marine areas • Do not pump flammable or explosive liquids, pump water only with this pump • To reduce risk of electrical shock, fully read, follow and save the operating and installation instructions before attempting to install or operate this pump • Do not run this pump dry • NOTICE: Do not handle pump with wet hands or when standing on a wet surface, or in water • Pump will be EXTREMELY LOUD when water is no longer pumped. UNPLUG IMMEDIATELY • This pump is not waterproofed. Do not submerge in any liquid MADE IN CHINA cord tag ADVERTENCIA SKU:1000 000 000 MODELO:ZE00802A • Conecte la bomba DIRECTAMENTE a una toma de tierra, nunca utilice un cable de extensión para proporcionar alimentación a la bomba • Desconecte la bomba antes de cualquier clase de mantenimiento • Esta bomba no se ha puesto a prueba y no ha sido aprobada para uso en piscinas o en áreas de agua salada • No bombee líquidos inflamables o explosivos, bombee solamente agua con esta bomba • Para reducir el riesgo de descarga eléctrica, lea totalmente, siga y guarde las instrucciones de uso e instalación antes de intentar instalar o utilizar la bomba • No haga funcionar esta bomba en seco • AVISO: No maneje la bomba con las manos mojadas o estando en agua o en la superficie mojada • La bomba resultar demasiado alto cuando el agua ya no se bombea. Desenchufe inmediatamente • Esta bomba no está impermeabilizado. No lo sumerja en ningún líquido. HECHO EN CHINA Guía de Referencia Rápida Bomba de transferencia para no sumergible Es importante leer el manual para obtener información sobre la instalación, la operación y la seguridad.Esta guía no complementa ni reemplaza al Manual del Propietario. NO HAGA FUNCIONAR LA BOMBA EN SECO! El funcionamiento en seco, se anulará la garantía y el daño de la bomba. 1. Añada agua (aproximadamente 1 a 2 cucharadas) en la entrada para mojar el impulsor de la bomba. 2. Conecte la manguera de succión transparente (se incluye) en el colador de succión (se incluye) al empujar el extremo roscado macho en el acoplador de goma del colador de succión. Coloque el colador al menos 1,27 cm en el punto más bajo de agua que sedebe bombear. AVISO: Verifique que la conexión esté cerrada herméticamente. Una fuga de aire puede hacer que la bomba funcione en seco. 3. Enrosque el otro extremo de la manguera de succión transparente a la entrada de succión de la bomba. AVISO: Asegúrese siempre de que el conector de la manguera no esté dañado. Es necesario un sello hermético para que esta bomba funcione. Asegúrese de que la manguera transparente y el colador de succión se encuentren en el agua antes de conectar la bomba. 4. Enrosque una manguera de jardín de 1,59 cm o más grande (se vende por separado, longitud máx. de 15,24 m) en la salida de descarga de la bomba. AVISO: Asegúrese de que el extremo de la manguera de salida no esté debajo del agua. Si la salida está bajo agua, puede que la bomba no funcione. AVISO: Nunca haga funcionar esta bomba a menos que se fije a una base sólida. 5. Adhiera la bomba a una base fuerte (mesa, tabla, etc.) para evitar que se vuelque. Asegúrese de que las mangueras estén lo más rectas posibles. ADVERTENCIA: Esta bomba NO PUEDE estar sumergida en agua y el motor NO PUEDE mojarse para nada. ¡Mojar el motor podría causar electrocución, lo que podría provocar lesiones graves o la muerte! AVISO: No enrolle ni doble la manguera. 6. Para hacerla funcionar, conecte la bomba a un tomacorriente GFCI. AVISO: Esta bomba puede ser muy ruidosa cuando se la enchufa. Cuando el nivel de agua se ha reducido a aproximadamente 3,18 mm, DEBE DESCONECTAR LA BOMBA. NO LA HAGA FUNCIONAR EN SECO. La bomba es EXTREMADAMENTE RUIDOSA cuando ha dejado de bombear agua. AVISO: Si no se bombea agua en 30 segundos, desconecte el cable eléctrico y compruebe la conexión de los dos extremos de la manguera de entrada para asegurarse de que no haya fugas de aire. A continuación, añada agua a la entrada de nuevo y repita el proceso. NO BOBINAS! Existan dobleces! al menos de 1/2 " Let Us Help You ! Permítanos Help ! Do not return your product to the store. Call us first! If you have questions regarding your product or require warranty assistance, please call our customer service toll-free helpline No devuelva su proudct a la tienda. Llámenos primero! Si tiene alguna pregunta con respecto a su producto o si necesita asistencia con la garantía, por favor llame a nuestra línea de ayuda de servicio al cliente de gratis 1-844-241-5521 Contact us for assistance, we're here to help. En contacto con nosotros para obtener ayuda, estamos aquí para ayudar.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Everbilt ZE00802A Guía del usuario

Categoría
Bombas de agua
Tipo
Guía del usuario

En otros idiomas