Before Assembly
1. Make sure that the fan voltage (120) is compatible with your own electrical
system.
2. Check to make sure that your carton contains all the parts mentioned in the
parts list.
NOTE: When the motor is taken out of carton, please put it in a soft cloth to prevent
any damage on the ornamental surface.
CAUTION: Before installing, choose a location for mounting the fan where the
blades have at least 7 feet of clearance from all objects and floor. Mount an outlet
box to the ceiling or use an existing box.
CAUTION: Do not mount fan to sheet rock or drywall type materials. To insure
proper support, use the two #1 wood screws to secure mounting bracket to joist or
beam. If the location you choose does not have a suitable support beam, install a
2”X4” brace between ceiling joists to support.
Antes del montaje
1. Revise que el voltaje (120) del ventilador sea compatible con su propio sistema
eléctrico.
2. Compruebe que la caja contenga todas las piezas mencionadas en la lista
correspondiente.
NOTA: Cuando se extraiga el motor de la caja, póngalo sobre un paño suave para
evitar dañar la superficie ornamental.
PRECAUCIÓN: Antes de instalar, elija una ubicación para montar el ventilador
donde las aspas tengan por lo menos 7 pies (2.1 m) de altura desde el piso y todo
objeto. Monte una caja de salida en el cielo raso o use una caja existente.
PRECAUCIÓN: No monte el ventilador en materiales de tipo tablaroca o paneles
de yeso. Para asegurar un soporte adecuado use los dos tornillos para madera (1) para
asegurar el soporte de montaje a la viga. Si la ubicación que ha seleccionado no tiene
una viga de soporte que sirva, instale una abrazadera de 2" x 4" (5 x 10 cm) entre
las vigas del cielo raso para soportar el ventilador.
Tools You Need / Herramientas necesarias
2. Adjustable Wrench
2. Llava ajustable
1. Phillips Screwdriver (included)
1. Destornillador Phillips (incluido)
3. Wire Strippers
3. Pelacables
2. Flat Screwdriver
2. Destornillador
de hoja plana
Read and Save These Safety Precautions
1. Turn off electricity at main switch before wiring or servicing fan in order to avoid
possible electrical shock.
2. All wiring must be in accordance with the National Electric Code (ANSI/NFPA 70-
1999) and local electrical codes. Electrical installation should be performed by a qualified
licensed electrician.
3. After making the wire connections, the wires should be spread apart with the grounded
conductor and the equipment-grounding conductor on the one side of the outlet box
and the ungrounded conductor on the other side of the outlet box.
4. The splices after being made should be turned upward and pushed carefully up into
the outlet box.
5. Conductor of a fan identified as grounded conductor to be connected to grounded
conductor of power supply, conductor of a fan identified as ungrounded conductor to
be connected to an ungrounded conductor of power supply, conductor of fan identified
for equipment grounding to be connected to an equipment-grounding conductor.
6. Fan should not be mounted in an area where it might get wet.
7. To r educe the risk of fire, electric shock or personal injury, mount to outlet box marked
"Acceptable for Fan Support" and use mounting screws provide with the outlet box.
8. For safety and best operating results, we recommend that you have a qualified electrician
assemble and install your fan.
9. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any
solid state speed control device.
10. To reduce the risk of personal injury, do not bend the blade brackets when installing
the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
Lea y conserve estas precauciones de seguridad
1. Apague la electricidad con el interruptor principal antes de cablear o dar servicio al
ventilador para evitar posibles choques eléctricos.
2. Todo el cableado eléctrico debe acatar los códigos eléctricos nacionales (ANSI/NFPA
70-1999) y los códigos eléctricos locales. Un electricista capacitado debe realizar la
instalación eléctrica.
3. Después de realizar las conexiones de cableado, deben separarse los cables con el
conductor a tierra y el conductor de tierra del equipo en un lado de la caja de salida y
el conductor sin tierra al otro lado de la caja de salida.
4. Una vez efectuados los empalmes deben girarse hacia arriba y empujarse con cuidado
dentro de la caja de salida.
5. El conductor de un ventilador identificado como conductor a tierra debe conectarse
al conductor a tierra de un suministro de alimentación, el conductor de un ventilador
identificado como conductor sin tierra debe conectarse a un conductor sin tierra del
suministro de alimentación; el conductor de un ventilador identificado para conectar
a tierra el equipo debe conectarse a un conductor para tal efecto.
6. No debe montarse el ventilador en un área donde pueda mojarse
7. Para aminorar el riesgo de un incendio, choque eléctrico o lesión personal, móntelo a
una caja de salida adecuada para soportar el ventilador ("Acceptable for Fan Support")
y utilice los tornillos de montaje incluidos con la caja de salida.
8. Por motivos de seguridad y para obtener óptimos resultados, recomendamos que pida
a un electricista capacitado ensamblar e instalar el ventilador.
9. ADVERTENCIA: Para reducir el peligro de incendio o choque eléctrico, no use este
ventilador con ningún dispositivo de control de velocidad de estado sólido.
10. Para aminorar el riesgo de una lesión personal, no doble los soportes de las aspas al
instalar los soportes, equilibrar las aspas o limpiar el ventilador. No introduzca objetos
extraños entre las aspas giratorias del ventilador.