Infinity Drain FFAS 2560 SS Instrucciones de operación

Tipo
Instrucciones de operación
Fixed Flange Series
Side Outlet Series
Installation Instructions
The Fixed Flange Series & Side Outlet Series are intended for use with the following
waterproong methods:
°
Liquid Waterproofing
°
Fabric Waterproofing
Dimension are subject to Manufacturers tolerance and change without notice. We can assume no responsibility for
use of superseded or void data.
Las dimensiones están sujetos a la tolerancia del fabricante y cambio sin previo aviso. No podemos asumir ninguna
responsabilidad por el uso de datos a sustituir los nulos.
Infinity Drain18 Secatoag Avenue, Port Washington, New York 11050
Phone 516.767.6786 • Fax 516.740.3066 www.InfinityDrain.com
Made in the U.S.A.
FFED 25
FTED 25
FFED 65
FTED 65
FFAS 125
FFMN 25
FTMN 25
FFMN 65
FTMN 65
FTC
CUSTOM
FFDG 25
FTDG 25
FFDG 65
FTDG 65
FFC CUSTOM
FFAS 25
FTAS 25
FFAS 65
FTAS 65
FFTIF 65
FTTIF 65
2
Fixed Flange (FF) Series Components:
SS=Stainless Steel
FFED 25 Series
EA 6532 32″ SS Grate
EA 6536 36″ SS Grate
EA 6542 42″ SS Grate
EA 6548 48" SS Grate
EA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FFED 65 Series
EA 6524 24" SS Grate
EA 6532 32″ SS Grate
EA 6536 36″ SS Grate
EA 6542 42″ SS Grate
EA 6548 48" SS Grate
EA 6560 60" SS Grate
FC 6524 24"SS Fixed Channel
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
HF 2 2" Hair Strainer
FFTIF 65 Series
LA 6524 24" SS Grate
LA 6532 32″ SS Grate
LA 6536 36″ SS Grate
LA 6542 42″ SS Grate
LA 6548 48" SS Grate
LA 6560 60" SS Grate
FC 6524 24"SS Fixed Channel
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
HF 2 2" Hair Strainer
FFDG 65 Series
DA 6532 32″ SS Grate
DA 6536 36″ SS Grate
DA 6542 42″ SS Grate
DA 6548 48" SS Grate
DA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
HF 2 2" Hair Strainer
FFAS 125 Series
SA 12532 32" SS Grate
SA 12536 36" SS Grate
SA 12542 42" SS Grate
SA 12548 48" SS Grate
SA 12560 60" SS Grate
FC 12532 32" SS Fixed Channel
FC 12536 36" SS Fixed Channel
FC 12542 42" SS Fixed Channel
FC 12548 48" SS Fixed Channel
FC 12560 60" SS Fixed Channel
FFDG 25 Series
DA 6532 32″ SS Grate
DA 6536 36″ SS Grate
DA 6542 42″ SS Grate
DA 6548 48" SS Grate
DA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FFMN 25 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS Grate
MA 6542 42″ SS Grate
MA 6548 48" SS Grate
MA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FFAS 25 Series
SA 6532 32″ SS Grate
SA 6536 36″ SS Grate
SA 6542 42″ SS Grate
SA 6548 48" SS Grate
SA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FFMN 65 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS Grate
MA 6542 42″ SS Grate
MA 6548 48" SS Grate
MA 6560 60" SS Grate
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
HF 2 2" Hair Strainer
FFAS 65 Series
SA 6524 24" SS Grate
SA 6532 32″ SS Grate
SA 6536 36″ SS Grate
SA 6542 42″ SS Grate
SA 6548 48" SS Grate
SA 6560 60" SS Grate
FC 6524 24"SS Fixed Channel
FC 6532 32" SS Fixed Channel
FC 6536 36" SS Fixed Channel
FC 6542 42" SS Fixed Channel
FC 6548 48" SS Fixed Channel
FC 6560 60" SS Fixed Channel
HF 2 2" Hair Strainer
Note: Installer must verify all rough-in
dimensions prior to installation and consult
local and national codes. Conformity and
compliance to local and national codes are
the responsibility of the installer.
Tenga en cuenta: Instalador debe
comprobar todas las dimensiones en las
partes previa a la instalación y consultar
localmente y nacionalmente los códigos.
La conformidad y el cumplimiento de
códigos local y nacional es responsabilidad
del instalador.
3
FTED 25 Series
EA 6532 32″ SS Grate
EA 6536 36″ SS Grate
EA 6542 42″ SS Grate
EA 6548 48" SS Grate
EA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FTDG 25 Series
DA 6532 32″ SS Grate
DA 6536 36″ SS Grate
DA 6542 42″ SS Grate
DA 6548 48" SS Grate
DA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FTMN 25 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS Grate
MA 6542 42″ SS Grate
MA 6548 48" SS Grate
MA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FTAS 25 Series
SA 6532 32″ SS Grate
SA 6536 36″ SS Grate
SA 6542 42″ SS Grate
SA 6548 48" SS Grate
SA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
CI 2532 32" SS Channel Insert
CI 2536 36" SS Channel Insert
CI 2542 42" SS Channel Insert
CI 2548 48" SS Channel Insert
CI 2560 60" SS Channel Insert
FTED 65 Series
EA 6524 24" SS Grate
EA 6532 32″ SS Grate
EA 6536 36″ SS Grate
EA 6542 42″ SS Grate
EA 6548 48" SS Grate
EA 6560 60" SS Grate
OC 6524 24"SS Fixed Channel
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
FTTIF 65 Series
LA 6524 24" SS Grate
LA 6532 32″ SS Grate
LA 6536 36″ SS Grate
LA 6542 42″ SS Grate
LA 6548 48" SS Grate
LA 6560 60" SS Grate
OC 6524 24"SS Fixed Channel
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
FTDG 65 Series
DA 6532 32″ SS Grate
DA 6536 36″ SS Grate
DA 6542 42″ SS Grate
DA 6548 48" SS Grate
DA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
FTMN 65 Series
MA 6532 32″ SS Grate
MA 6536 36″ SS Grate
MA 6542 42″ SS Grate
MA 6548 48" SS Grate
MA 6560 60" SS Grate
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
FTAS 65 Series
SA 6524 24" SS Grate
SA 6532 32″ SS Grate
SA 6536 36″ SS Grate
SA 6542 42″ SS Grate
SA 6548 48" SS Grate
SA 6560 60" SS Grate
OC 6524 24"SS Fixed Channel
OC 6532 32" SS Fixed Channel
OC 6536 36" SS Fixed Channel
OC 6542 42" SS Fixed Channel
OC 6548 48" SS Fixed Channel
OC 6560 60" SS Fixed Channel
Optional Components: (Not Included)
ST 65 Placement Brackets for FF25/FF65 Series
ST 125 Placement Brackets for FF125 Series
Side Outlet (FT) Series Components:
SS=Stainless Steel
4
Note: Installer must verify all rough-
in dimensions prior to installation
and consult local and national codes.
Conformity and compliance to local and
national codes are the responsibility of
the installer.
Tenga en cuenta: Instalador debe
comprobar todas las dimensiones en las
partes previa a la instalación y consultar
localmente y nacionalmente los códigos.
La conformidad y el cumplimiento de
códigos local y nacional es responsabilidad
del instalador.
Drain can be adjusted upward
for an additional ½” in height.
Drain can be adjusted upward
for an additional ½” in height.
Section A-A
FFED 25, FFDG 25,
FFMN 25, FFAS 25
Section A-A
FFED 65, FFDG 65,
FFMN 65, FFAS 65
Section A-A
FFTIF 65
Section A-A
FFAS 125
¹⁶
"
¹³⁄
¹⁶
"
1"
2¼"
3"
¹⁶
"
¹³⁄
¹⁶
"
2½"
2¼"
3"
1³⁄
¹⁶
"
¹³⁄
¹⁶
"
2½"
2"
⅜"
2¼"
3"
¹⁶
"
4¹³
¹⁶
"
¹³⁄
¹⁶
"
3¼"
3"
Side Outlet (FT) Series:
Section B-B
FTED 25, FTDG 25,
FTMN 25, FTAS 25
Section B-B
FTED 65, FTDG 65,
FTMN 65, FTAS 65
Section B-B
FTTIF 65
1¹⁄
¹⁶
"
1"
2¼"
2⅞"
1¹⁄
¹⁶
"
2½"
2¼"
2⅞"
¹⁶
"
2½"
2"
⅜"
2¼"
2⅞"
Fixed Flange (FF) Series:
5
Installation
1. Locate the waste line position. Typically
linear drains span a dimension from wall to
wall, against a wall or at a shower entrance.
FF (Fixed Flange Series) only:
2. Spread a prelimainary mortar bed across the
intended drain location. Set drain into mortar
bed. Connect the outlet section (D) to the
existing waste pipe (F) via 2no hub connection
using a 2DWV no hub rubber coupling (E). Allow
stainless steel channel (C) to sit onto suboor.
FT (Side Outlet Series) only:
2. Connect the outlet section (D) to the
existing waste pipe (F) via 2” no hub
connection using a 2” DWV no hub rubber
coupling (E). Be sure to use integrated drain
supports to support the stainless steel
channel (C) at the desired height.
Note: When drain install is required to
be ush against the nished wall, backer
board will install over the 1” ange of the
drain body.
Instalación
1. Localize la posición de la línea de residuos.
picamente los drenajes lineales extienden
a una dimensión desde pared a pared, contra
una pared, o en una entrada del baño.
Solo FT (Side Outlet Series):
2. Conecte la sección de salida (D) a la tubería
de residuos existente (F) a través de 2” sin
conexn concentrado usando DWV ningún
acoplamiento elástico (E). Asegúrese de
utilizar un drenaje integrado para soportar el
canal de acero (C) a la longitud desea.
Solo FF (Fixed Flange Series):
2. Conecte la sección de salida (D) a la
tubería existente (F) vía 2conexn sin
concentrador usando 2DWV goma de
acoplamiento (E). Permita el canal de acero
(C) sentarse en el subsuelo.
Tenga en cuenta: Cuando el drenaje se
instale es necesario que este contra la
pared terminada, placa de cemento se
instalara sobre 1” brida del drenaje.
*Not provided by Innity Drain kits
FIXED FLANGE (FF) SERES
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adjustable Feet
Liquid/Fabric
Waterproong
(C) Bottom
Channel – FC 65
(D) Vertical O utle t
(E) Rubber Coupling*
(F) Waste Pipe
KEY
SIDE OUTLET (FT) SERIES
KEY
Liquid/Fabric
Waterproong
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adjustable Feet
(C) Bottom
Channel – OC 65
(D) Side Outlet
(E) Rubber Coupling*
(F) Waste Pipe
(C) Bottom Channel – FC 65
(D) Vertical
Outlet
(E) Rubber
Coupling*
(F) Waste Pipe
FF Series
(C) Bottom Channel – OC 65
(D) Side Outlet
Drain
Supports
(E) Rubber Coupling*
(F) Waste Pipe
FT Series
6
Limited waste pipe access:
Measure the distance from the top of the
existing waste line to the top of the suboor.
Ensure that the outlet section (D) is at
minimum of 2” less than this dimension,
cut the 3” length of the outlet section (D) if
necessary. DO NOT remove more than 2” from
the outlet section. Determine the distance
from the bottom of the outlet section (D) to
the top of the existing waste pipe (F). Cut a 2
PVC or ABS pipe to a length 1/8” less than this
dimension. Bond the 2” PVC/ABS pipe to a 2
DWV PVC/ABS coupling using PVC/ABS primer
and cement. Connect the other end of the 2
PVC/ABS pipe to the outlet section (D) via a 2
DWV no hub rubber coupling. Bond the free
end of the 2” pipe and coupling assembly to
the existing waste pipe using PVC/ABS primer
and cement.
3. Spread a mortar bed across the intended
shower area and ensure the drain channel
(C) is level. Back ll region under the channel
ange so that pitch begins level to the edge of
the stainless steel channel (C). Pitch this bed
one plane towards the drain body.
4. When mortar layer is dry, perform
necessary waterproong (liquid membrane or
fabric sheet membrane) as per local code and
manufacturers’ instructions. Paint or bond
waterproong directly to the channel’s ange.
5. After waterproong is completely dry, lay
thinset and nishing material. Finish material
on to the channel ange. DO NOT allow tile to
nish over the depth of the channel.
Límite acceso de tubería de residuos:
Medir la distancia desde la parte superior
de la línea de residuos existentes a la parte
superior del subsuelo. Asegúrese que la
sección de salida (D) este mínimo 2” menos de
la dimensión, corte 3” de largo de la seccn
de salida (D) si es necesario. NO REMUEVE
más de 2.5” de la sección de salida. Determine
la distancia desde debajo de la seccn de
salida (D) a la parte superior de la tubería
existente (F). Corte un tubo de PVC o ABS a 2
a lo largo 1/8” menos de la dimensión. Una la
2” de tubería de PVC/ABS a 2” DWV PVC/ABS
de acoplamiento usando PVC/ABS primer y
cemento. Conecte la otra parte de 2” de tubería
PVC/ABS a la seccn de salida (D) vía a 2” DWV
sin ninn acoplamiento elástico. Una la parte
nal de la 2” de la tubería y la asamblea de
acoplamiento a la existencia de la tubería de
residuos usando PVC/ABS primer y cemento.
3. Extienda mortero a través del baño
previsto y asegure que el canal (C) este
anivelado. Rellene la regn baja del canal
para que comience a brear a nivel del borde
del canal de acero (C). Bree esto a un plano
hacia el drenaje.
4. Cuando el motero este seco, realice la
necesaria impermeabilización (Membrana de
liquidó o membrana de tejido) sen las reglas
locales y las instrucciones del fabricante. Pinte
o enlace la impermeabilización directamente
al reborde del canal.
5. Después de que la impermeabilización se
seque por completo, colocar el thinset y el
material terminado. El material terminado
hasta el borde del canal. NO PERMITA o DEJE
que el tile termine encima de la profundidad
del canal.
Note: When oor pitch is needed to begin
at a zero level, determine the length of
the channel (B) less the 1” ange around
it’s perimeter. Cut a hole in the suboor to
the measured dimensions at the desired
location. Place the ST65/ST125 Placement
Brackets (Optional Component) in the newly
created hole and screw into suboor. Recess
the stainless steel channel (C) into the
suboor and bracket. Allow the 1” ange to
sit onto the suboor.
Tenga en cuenta: Cuando el piso sea pitch
es necesario que comienza a un cero nivel,
determine la longitud del canal (B) menos de
1” alrededor del pemetro. Corte un agujero
en el subsuelo a la dimensión medida de la
ubicación deseada. Colocar el ST65/ST125
soportes de colocación (Componentes
Opcionales) en el recién agujero y atornille en
el subsuelo. Empotrar el canal de acero (C)
en el subsuelo y soporte. Permita el 1”brida
que este sentado en el subsuelo.
7
Mortar Bed
Sub-oor
Waterproong
Membrane
Mortar Bed
Sub-oor
Waterproong
Membrane
Before nishing material • Antes que el material esté terminado
Tile
Assure that
grate is
lower than
installed tile
Tile
Assure that
grate is
lower than
installed tile
After nishing material • Desps que el material esté terminado
6. Place nished top grate (A) into the
installed bottom channel (C). Use adjustable
feet (B) to raise or lower the top grate to be
1/16” below the nishing material height.
6. Coloque la rejilla superior (A) en la parte
inferior del canal instalado (C). Utilicé ajustables
pies para levantar o bajar la rejilla a ser 1/16”
debajo de la altura del material terminado.
Model
Minimum
Height
Maximum
Height
FFED25/FFED65/
FFDG25/FFDG65/
FFMN25/FFMN65/
FFAS25/FFAS65/FFAS125
1/” 1/”
FFTIF 65
1³/” 1/”
Model
Minimum
Height
Maximum
Height
FTED25/FTED65/FTDG25/
FTDG65/FTMN25/
FTMN65/FTAS25/FTAS65/
FTAS125
1/ 1/
FTTIF 65
1³/ 1/”
(B) Adjustable Feet
Grate can be raised an
additional ½”
(B) Adjustable Feet
Grate can be raised an
additional ½”
7. FFTIF 65/FTTIF 65 INSTALL. Spread a layer
of mortar into the Tile Insert Frame (TA65),
allowing for thinset and and nishing material
to nish 1/16” above the metal frame. Allow to
dry, spread thinset and lay material.
7. FFTIF 65/FTTIF 65 INSTALACION. Extender
una capa de mortero en Tile Insert Frame
(TA65), permitiendo el thinset y material
terminado que termine 1/16” arriba del marco
del metal. Permita que se seque, extienda
thinset y coloca material.
8
FIXED FLANGE (FF) SERES
Suboor
Stainless Steel
Channel
Waste Line
Rubber Coupling
Mortar Bed
Liquid/Fabric
Waterproong
Finishing Material
Backer Board
Thinset
Finished Grate
SIDE OUTLET (FT) SERIES
Suboor
Stainless Steel
Channel
Rubber Coupling
Mortar Bed
Liquid/Fabric
Waterproong
Finishing Material
Backer Board
Thinset
Finished Grate

Transcripción de documentos

Fixed Flange Series Side Outlet Series Installation Instructions FFED 25 FTED 25 FFDG 25 FTDG 25 FFMN 25 FTMN 25 FFAS 25 FTAS 25 FFED 65 FTED 65 FFDG 65 FTDG 65 FFMN 65 FTMN 65 FFAS 65 FTAS 65 FFAS 125 FFC CUSTOM FTC CUSTOM FFTIF 65 FTTIF 65 The Fixed Flange Series & Side Outlet Series are intended for use with the following waterproofing methods: Liquid Waterproofing ° ° Fabric Waterproofing Made in the U.S.A. Infinity Drain • 18 Secatoag Avenue, Port Washington, New York 11050 Phone 516.767.6786 • Fax 516.740.3066 • www.InfinityDrain.com Dimension are subject to Manufacturers tolerance and change without notice. We can assume no responsibility for use of superseded or void data. Las dimensiones están sujetos a la tolerancia del fabricante y cambio sin previo aviso. No podemos asumir ninguna responsabilidad por el uso de datos a sustituir los nulos. Fixed Flange (FF) Series Components: SS=Stainless Steel FFED 25 Series FFDG 25 Series FFMN 25 Series FFAS 25 Series EA 6532 32″ SS Grate DA 6532 32″ SS Grate MA 6532 32″ SS Grate SA 6532 32″ SS Grate EA 6536 36″ SS Grate DA 6536 36″ SS Grate MA 6536 36″ SS Grate SA 6536 36″ SS Grate EA 6542 42″ SS Grate DA 6542 42″ SS Grate MA 6542 42″ SS Grate SA 6542 42″ SS Grate EA 6548 48" SS Grate DA 6548 48" SS Grate MA 6548 48" SS Grate SA 6548 48" SS Grate EA 6560 60" SS Grate DA 6560 60" SS Grate MA 6560 60" SS Grate SA 6560 60" SS Grate FC 6532 32" SS Fixed Channel FC 6532 32" SS Fixed Channel FC 6532 32" SS Fixed Channel FC 6532 32" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6560 60" SS Fixed Channel FC 6560 60" SS Fixed Channel FC 6560 60" SS Fixed Channel FC 6560 60" SS Fixed Channel CI 2532 32" SS Channel Insert CI 2532 32" SS Channel Insert CI 2532 32" SS Channel Insert CI 2532 32" SS Channel Insert CI 2536 36" SS Channel Insert CI 2536 36" SS Channel Insert CI 2536 36" SS Channel Insert CI 2536 36" SS Channel Insert CI 2542 42" SS Channel Insert CI 2542 42" SS Channel Insert CI 2542 42" SS Channel Insert CI 2542 42" SS Channel Insert CI 2548 48" SS Channel Insert CI 2548 48" SS Channel Insert CI 2548 48" SS Channel Insert CI 2548 48" SS Channel Insert CI 2560 60" SS Channel Insert CI 2560 60" SS Channel Insert CI 2560 60" SS Channel Insert CI 2560 60" SS Channel Insert FFED 65 Series FFDG 65 Series FFMN 65 Series FFAS 65 Series EA 6524 24" SS Grate DA 6532 32″ SS Grate MA 6532 32″ SS Grate SA 6524 24" SS Grate EA 6532 32″ SS Grate DA 6536 36″ SS Grate MA 6536 36″ SS Grate SA 6532 32″ SS Grate EA 6536 36″ SS Grate DA 6542 42″ SS Grate MA 6542 42″ SS Grate SA 6536 36″ SS Grate EA 6542 42″ SS Grate DA 6548 48" SS Grate MA 6548 48" SS Grate SA 6542 42″ SS Grate EA 6548 48" SS Grate DA 6560 60" SS Grate MA 6560 60" SS Grate SA 6548 48" SS Grate EA 6560 60" SS Grate FC 6532 32" SS Fixed Channel FC 6532 32" SS Fixed Channel SA 6560 60" SS Grate FC 6524 24"SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6524 24"SS Fixed Channel FC 6532 32" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6532 32" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6548 48" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6560 60" SS Fixed Channel FC 6560 60" SS Fixed Channel FC 6542 42" SS Fixed Channel FC 6548 48" SS Fixed Channel HF 2 HF 2 FC 6548 48" SS Fixed Channel 2" Hair Strainer 2" Hair Strainer FC 6560 60" SS Fixed Channel FC 6560 60" SS Fixed Channel HF 2 HF 2 2" Hair Strainer FFAS 125 Series FFTIF 65 Series SA 12532 32" SS Grate LA 6524 24" SS Grate SA 12536 36" SS Grate LA 6532 32″ SS Grate SA 12542 42" SS Grate LA 6536 36″ SS Grate SA 12548 48" SS Grate LA 6542 42″ SS Grate SA 12560 60" SS Grate LA 6548 48" SS Grate FC 12532 32" SS Fixed Channel LA 6560 60" SS Grate FC 12536 36" SS Fixed Channel FC 6524 24"SS Fixed Channel FC 12542 42" SS Fixed Channel FC 6532 32" SS Fixed Channel FC 12548 48" SS Fixed Channel FC 6536 36" SS Fixed Channel FC 12560 60" SS Fixed Channel FC 6542 42" SS Fixed Channel Note: Installer must verify all rough-in dimensions prior to installation and consult local and national codes. Conformity and compliance to local and national codes are the responsibility of the installer. Tenga en cuenta: Instalador debe comprobar todas las dimensiones en las partes previa a la instalación y consultar localmente y nacionalmente los códigos. La conformidad y el cumplimiento de códigos local y nacional es responsabilidad del instalador. FC 6548 48" SS Fixed Channel FC 6560 60" SS Fixed Channel HF 2 2" Hair Strainer 2" Hair Strainer 2 Side Outlet (FT) Series Components: SS=Stainless Steel FTED 25 Series FTDG 25 Series FTMN 25 Series EA 6532 32″ SS Grate DA 6532 32″ SS Grate MA 6532 32″ SS Grate EA 6536 36″ SS Grate DA 6536 36″ SS Grate MA 6536 36″ SS Grate EA 6542 42″ SS Grate DA 6542 42″ SS Grate MA 6542 42″ SS Grate EA 6548 48" SS Grate DA 6548 48" SS Grate MA 6548 48" SS Grate EA 6560 60" SS Grate DA 6560 60" SS Grate MA 6560 60" SS Grate OC 6532 32" SS Fixed Channel OC 6532 32" SS Fixed Channel OC 6532 32" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6560 60" SS Fixed Channel OC 6560 60" SS Fixed Channel OC 6560 60" SS Fixed Channel CI 2532 32" SS Channel Insert CI 2532 32" SS Channel Insert CI 2532 32" SS Channel Insert CI 2536 36" SS Channel Insert CI 2536 36" SS Channel Insert CI 2536 36" SS Channel Insert CI 2542 42" SS Channel Insert CI 2542 42" SS Channel Insert CI 2542 42" SS Channel Insert CI 2548 48" SS Channel Insert CI 2548 48" SS Channel Insert CI 2548 48" SS Channel Insert CI 2560 60" SS Channel Insert CI 2560 60" SS Channel Insert CI 2560 60" SS Channel Insert FTAS 25 Series FTED 65 Series FTDG 65 Series SA 6532 32″ SS Grate EA 6524 24" SS Grate DA 6532 32″ SS Grate SA 6536 36″ SS Grate EA 6532 32″ SS Grate DA 6536 36″ SS Grate SA 6542 42″ SS Grate EA 6536 36″ SS Grate DA 6542 42″ SS Grate SA 6548 48" SS Grate EA 6542 42″ SS Grate DA 6548 48" SS Grate SA 6560 60" SS Grate EA 6548 48" SS Grate DA 6560 60" SS Grate OC 6532 32" SS Fixed Channel EA 6560 60" SS Grate OC 6532 32" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6524 24"SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6532 32" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6560 60" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6560 60" SS Fixed Channel CI 2532 32" SS Channel Insert OC 6548 48" SS Fixed Channel CI 2536 36" SS Channel Insert OC 6560 60" SS Fixed Channel CI 2542 42" SS Channel Insert CI 2548 48" SS Channel Insert CI 2560 60" SS Channel Insert FTMN 65 Series FTAS 65 Series FTTIF 65 Series MA 6532 32″ SS Grate SA 6524 24" SS Grate LA 6524 24" SS Grate MA 6536 36″ SS Grate SA 6532 32″ SS Grate LA 6532 32″ SS Grate MA 6542 42″ SS Grate SA 6536 36″ SS Grate LA 6536 36″ SS Grate MA 6548 48" SS Grate SA 6542 42″ SS Grate LA 6542 42″ SS Grate MA 6560 60" SS Grate SA 6548 48" SS Grate LA 6548 48" SS Grate OC 6532 32" SS Fixed Channel SA 6560 60" SS Grate LA 6560 60" SS Grate OC 6536 36" SS Fixed Channel OC 6524 24"SS Fixed Channel OC 6524 24"SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6532 32" SS Fixed Channel OC 6532 32" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6536 36" SS Fixed Channel OC 6560 60" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6542 42" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6548 48" SS Fixed Channel OC 6560 60" SS Fixed Channel OC 6560 60" SS Fixed Channel Optional Components: (Not Included) ST 65 ST 125 Placement Brackets for FF25/FF65 Series Placement Brackets for FF125 Series 3 Tenga en cuenta: Instalador debe comprobar todas las dimensiones en las partes previa a la instalación y consultar localmente y nacionalmente los códigos. La conformidad y el cumplimiento de códigos local y nacional es responsabilidad del instalador. Note: Installer must verify all roughin dimensions prior to installation and consult local and national codes. Conformity and compliance to local and national codes are the responsibility of the installer. Fixed Flange (FF) Series: 1" Drain can be adjusted upward for an additional ½” in height. 2½" 1¹⁄¹⁶" 2½" ¹³⁄¹⁶" 2" 1¹⁄¹⁶" ¹³⁄¹⁶" 3" ¹³⁄¹⁶" 3" 2¼" Section A-A FFED 65, FFDG 65, FFMN 65, FFAS 65 4¹³⁄¹⁶" 1³⁄¹⁶" ¹³⁄¹⁶" 3" 1¹⁄¹⁶" 3" 2¼" 3¼" Section A-A FFTIF 65 Section A-A FFAS 125 2¼" Section A-A FFED 25, FFDG 25, FFMN 25, FFAS 25 ⅜" Side Outlet (FT) Series: Drain can be adjusted upward for an additional ½” in height. 2½" 1" 2⅞" 2¼" Section B-B FTED 25, FTDG 25, FTMN 25, FTAS 25 2½" 1¹⁄¹⁶" 2" 1¹⁄¹⁶" 2⅞" 1³⁄¹⁶" 2⅞" 2¼" Section B-B FTED 65, FTDG 65, FTMN 65, FTAS 65 4 ⅜" 2¼" Section B-B FTTIF 65 FIXED FLANGE (FF) SERES KEY SIDE OUTLET (FT) SERIES KEY (A) Top Grate – EA/DA/MA/SA/LA Liquid/Fabric Waterproofing (A) Top Grate – (B) Adjustable Feet EA/DA/MA/SA/LA Liquid/Fabric Waterproofing (B) Adjustable Feet (C) Bottom Channel – OC 65 (C) Bottom Channel – FC 65 (D) Side Outlet (D) Vertical Outlet (E) Rubber Coupling* (E) Rubber Coupling* (F) Waste Pipe (F) Waste Pipe Installation Instalación 1. Locate the waste line position. Typically linear drains span a dimension from wall to wall, against a wall or at a shower entrance. 1. Localize la posición de la línea de residuos. Típicamente los drenajes lineales extienden a una dimensión desde pared a pared, contra una pared, o en una entrada del baño. Tenga en cuenta: Cuando el drenaje se instale es necesario que este contra la pared terminada, placa de cemento se instalara sobre 1” brida del drenaje. Note: When drain install is required to be flush against the finished wall, backer board will install over the 1” flange of the drain body. Solo FF (Fixed Flange Series): FF (Fixed Flange Series) only: 2. Conecte la sección de salida (D) a la tubería existente (F) vía 2” conexión sin concentrador usando 2” DWV goma de acoplamiento (E). Permita el canal de acero (C) sentarse en el subsuelo. 2. Spread a prelimainary mortar bed across the intended drain location. Set drain into mortar bed. Connect the outlet section (D) to the existing waste pipe (F) via 2” no hub connection using a 2” DWV no hub rubber coupling (E). Allow stainless steel channel (C) to sit onto subfloor. FF Series FT Series (C) Bottom Channel – OC 65 (D) Vertical Outlet Drain Supports (E) Rubber Coupling* (E) Rubber Coupling* (F) Waste Pipe (D) Side Outlet (C) Bottom Channel – FC 65 (F) Waste Pipe Solo FT (Side Outlet Series): FT (Side Outlet Series) only: 2. Conecte la sección de salida (D) a la tubería de residuos existente (F) a través de 2” sin conexión concentrado usando DWV ningún acoplamiento elástico (E). Asegúrese de utilizar un drenaje integrado para soportar el canal de acero (C) a la longitud desea. 2. Connect the outlet section (D) to the existing waste pipe (F) via 2” no hub connection using a 2” DWV no hub rubber coupling (E). Be sure to use integrated drain supports to support the stainless steel channel (C) at the desired height. 5 *Not provided by Infinity Drain kits Note: When floor pitch is needed to begin at a zero level, determine the length of the channel (B) less the 1” flange around it’s perimeter. Cut a hole in the subfloor to the measured dimensions at the desired location. Place the ST65/ST125 Placement Brackets (Optional Component) in the newly created hole and screw into subfloor. Recess the stainless steel channel (C) into the subfloor and bracket. Allow the 1” flange to sit onto the subfloor. Tenga en cuenta: Cuando el piso sea pitch es necesario que comienza a un cero nivel, determine la longitud del canal (B) menos de 1” alrededor del perímetro. Corte un agujero en el subsuelo a la dimensión medida de la ubicación deseada. Colocar el ST65/ST125 soportes de colocación (Componentes Opcionales) en el recién agujero y atornille en el subsuelo. Empotrar el canal de acero (C) en el subsuelo y soporte. Permita el 1”brida que este sentado en el subsuelo. Limited waste pipe access: Límite acceso de tubería de residuos: Measure the distance from the top of the existing waste line to the top of the subfloor. Ensure that the outlet section (D) is at minimum of 2” less than this dimension, cut the 3” length of the outlet section (D) if necessary. DO NOT remove more than 2” from the outlet section. Determine the distance from the bottom of the outlet section (D) to the top of the existing waste pipe (F). Cut a 2” PVC or ABS pipe to a length 1/8” less than this dimension. Bond the 2” PVC/ABS pipe to a 2” DWV PVC/ABS coupling using PVC/ABS primer and cement. Connect the other end of the 2” PVC/ABS pipe to the outlet section (D) via a 2” DWV no hub rubber coupling. Bond the free end of the 2” pipe and coupling assembly to the existing waste pipe using PVC/ABS primer and cement. Medir la distancia desde la parte superior de la línea de residuos existentes a la parte superior del subsuelo. Asegúrese que la sección de salida (D) este mínimo 2” menos de la dimensión, corte 3” de largo de la sección de salida (D) si es necesario. NO REMUEVE más de 2.5” de la sección de salida. Determine la distancia desde debajo de la sección de salida (D) a la parte superior de la tubería existente (F). Corte un tubo de PVC o ABS a 2” a lo largo 1/8” menos de la dimensión. Una la 2” de tubería de PVC/ABS a 2” DWV PVC/ABS de acoplamiento usando PVC/ABS primer y cemento. Conecte la otra parte de 2” de tubería PVC/ABS a la sección de salida (D) vía a 2” DWV sin ningún acoplamiento elástico. Una la parte final de la 2” de la tubería y la asamblea de acoplamiento a la existencia de la tubería de residuos usando PVC/ABS primer y cemento. 3. Spread a mortar bed across the intended shower area and ensure the drain channel (C) is level. Back fill region under the channel flange so that pitch begins level to the edge of the stainless steel channel (C). Pitch this bed one plane towards the drain body. 3. Extienda mortero a través del baño previsto y asegure que el canal (C) este anivelado. Rellene la región baja del canal para que comience a brear a nivel del borde del canal de acero (C). Bree esto a un plano hacia el drenaje. 4. When mortar layer is dry, perform necessary waterproofing (liquid membrane or fabric sheet membrane) as per local code and manufacturers’ instructions. Paint or bond waterproofing directly to the channel’s flange. 4. Cuando el motero este seco, realice la necesaria impermeabilización (Membrana de liquidó o membrana de tejido) según las reglas locales y las instrucciones del fabricante. Pinte o enlace la impermeabilización directamente al reborde del canal. 5. After waterproofing is completely dry, lay thinset and finishing material. Finish material on to the channel flange. DO NOT allow tile to finish over the depth of the channel. 5. Después de que la impermeabilización se seque por completo, colocar el thinset y el material terminado. El material terminado hasta el borde del canal. NO PERMITA o DEJE que el tile termine encima de la profundidad del canal. 6 Waterproofing Membrane Waterproofing Membrane Mortar Bed Mortar Bed Sub-floor Sub-floor Before finishing material • Antes que el material esté terminado Assure that grate is lower than installed tile Tile Assure that grate is lower than installed tile Tile After finishing material • Después que el material esté terminado 6. Place finished top grate (A) into the installed bottom channel (C). Use adjustable feet (B) to raise or lower the top grate to be 1/16” below the finishing material height. 6. Coloque la rejilla superior (A) en la parte inferior del canal instalado (C). Utilicé ajustables pies para levantar o bajar la rejilla a ser 1/16” debajo de la altura del material terminado. Grate can be raised an additional ½” Grate can be raised an additional ½” (B) Adjustable Feet (B) Adjustable Feet Model Minimum Height Maximum Height Model Minimum Height Maximum Height FFED25/FFED65/ FFDG25/FFDG65/ 11/₁₆” FFMN25/FFMN65/ FFAS25/FFAS65/FFAS125 19/₁₆” FTED25/FTED65/FTDG25/ FTDG65/FTMN25/ 11/₁₆” FTMN65/FTAS25/FTAS65/ FTAS125 19/₁₆” FFTIF 65 111/₁₆” FTTIF 65 111/₁₆” 1³/₁₆” 7. FFTIF 65/FTTIF 65 INSTALL. Spread a layer of mortar into the Tile Insert Frame (TA65), allowing for thinset and and finishing material to finish 1/16” above the metal frame. Allow to dry, spread thinset and lay material. 1³/₁₆” 7. FFTIF 65/FTTIF 65 INSTALACION. Extender una capa de mortero en Tile Insert Frame (TA65), permitiendo el thinset y material terminado que termine 1/16” arriba del marco del metal. Permita que se seque, extienda thinset y coloca material. 7 FIXED FLANGE (FF) SERES Backer Board Thinset Finished Grate Finishing Material Liquid/Fabric Waterproofing Mortar Bed Subfloor Rubber Coupling Waste Line Stainless Steel Channel SIDE OUTLET (FT) SERIES Backer Board Thinset Finished Grate Finishing Material Liquid/Fabric Waterproofing Mortar Bed Subfloor Rubber Coupling Stainless Steel Channel 8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Infinity Drain FFAS 2560 SS Instrucciones de operación

Tipo
Instrucciones de operación