Model 7865645 Water Pressure Pump 2.4
12V DC five chamber positive displacement diaphragm pump.
Typical applications
This pump is the ideal choice for pressurizing water
in a closed system such as that found in a boat or
in a recreational vehicle.
It can easily build the pressure required for a
pressurized water supply system.
Features
Quiet operation
Smooth flowing
Self priming
Integrated pressure switch turns pump on and off
automatically when tap is opened and closed
Dry running without damage
Low power consumption
Quick disconnect fittings
Working principle
As the pump runs, pressure builds until reaching
2.8 bar/41 psi. At this point, the integrated pressure
switch automatically shuts the pump off.
The pump is equipped with positively checking
outlet valves which ensure that the pressure is
maintained after the pump shuts off.
When water is demanded (at the faucet, shower,
etc.) the pressure decreases. After a moderate
drop in pressure, the integrated pressure switch
automatically turns the pump back on.
Due to it’s durable construction and thoughtful de-
sign, the pump will provide many years of service.
Important! The pressure setting of this pump is
made at the factory. Warranty invalidated by
pressure switch interference.
Specifications
Body: Polypropylene
Valve housing: Polyamide
Valves: EPDM
Diaphragm: Santoprene
Connection: ISO228/1-G
3/8" NPT, 1/2" (13mm)
hose and 1/2" NPT,
3/4" (19mm) hose
Liquid temperature: Max. +120°F (+50°C)
Fasteners: Stainless steel
Max. suction lift: 6.5 ft (2m)
Cut in pressure: 1.7 Bar/25 psi
Cut-off pressure: 2.8 Bar/41 psi
Duty cycle: Intermittent,
max 20 min
Motor: 87W, 12V DC
with built in
thermal protection
Weight: 3.5 lb (1.6kg)
The motor and switch are ignition protected
according to ISO 8846 (Small craft – Electrical
devices – Protection against ignition of surrounding
flammable gases).
Pressure and capacity data
Based on water at 68°F (+20°C) and at full voltage
of the motor.
Amperage
Pressure Flow draw
Bar kPa Psi L/min GPM 12V
0 0 0 9.4 2.4 2.5A
0.4 40 5.8 8.8 2.3 3.3A
0.8 80 11.6 8.1 2.1 4.0A
1.2 120 17.4 7.3 1.9 4.6A
1.6 160 23.2 6.7 1.8 5.2A
2.0 200 29 5.8 1.5 5.8A
2.4 240 34.8 4.9 1.3 6.4A
2.8 280 40.6 4.1 1.1 6.9A
Fuse required: 10A
ENGLISH
WPS2_4-InstructManual.indd 3 2/16/06 7:54:59 PM
4
Installation
Locate the pump in a dry location.
1. If the pump is mounted vertically, the motor shall
face up.
2. Mark screw positions and drill pilot holes
(see drilling template page 16).
3. Mount the pump using stainless steel screws
taking care not to over compress the vibration
dampening rubber feet.
4. Reinforced, high-pressure flexible tubing is
recommended. If rigid pipe is used, a length
(minimum 9"/225 mm) of flexible tubing shall be
installed between the pump and the rigid pipe.
This will address noise and/or damage caused by
vibration transmitted to rigid pipe.
5. Use stainless steel hose clamps to secure tubing
to quick disconnect fittings and other hose barbs
in the system.
NOTE: The strainer must be installed in line before
the pump intake, to prevent debris from entering
pump and interfering with proper functioning
of valves.
Electrical installation
1. The pump must be installed according to SS-EN
ISO 10133 (Small craft – Electrical system –
Extra low voltage DC installation for continous
current). Note: The fuse must be ignition
protected.
2. The motor is equipped with built in thermal
protection to prevent the motor from overheating.
The protection is automatically restored when the
motor is cooled.
3. If the pump is connected with separate earth
lead, this should be yellow/green and connected
to the motor base.
4. See the wiring table for correct installation.
Negative wire must be black. Choose wire size in
accordance with total wire length.
5. The wire connections must be sealed with a
marine sealant.
NOTE: Before installation with electrical control
systems, check that equipment to be used is of
sufficient rated capacity to accept amperage draw
of motor. Low voltage will cause motor to overheat.
Maintenance
The system shall be periodically sanitized using
the following procedure:
1. Fill the tank with a solution of household bleach
and potable watern .03 oz. (1ml) bleach to
32 oz. (1 L) water.
2. Open all faucets and run until water flowing
smells of bleach.
3. Close all faucets.
4. Drain solution from tank.
5. Refill tank with potable water.
6. Open all faucets and run until bleach has
been purged.
Max wire
Wire size length* in m
18 GA (1.0 mm
2
) 11.9
16 GA (1.5 mm
2
) 17.9
14 GA (2.5 mm
2
) 29.8
* The wire length is the total distance from the
battery to the pump and back to the battery.
It is recommended to use a relay with a light
wire from main cable to switch to shorten the
main leaders.
Wiring dimensions
(based on 10% voltage drop)
Other electrical devices, e.g. switch, circuit breaker,
must be installed between the pump and the
positive (+) lead on the battery (on the red wire).
Wiring table
Pump
Terminal
fuse
Max 8" (0.2m)
Red
Black
Green/yellow
+
ENGLISH
WPS2_4-InstructManual.indd 4 2/16/06 7:55:00 PM
5
There’s nothing more important to us than customer satisfaction.
If you have any questions or your purchase does not meet your
expectations, please do one of the following:
Contact your local West Marine store
Call 1-800-BOATING
Contact us at www.westmarine.com
Start-up procedure
After pump installation, the system can be started
by using the following procedure:
Fill water tank
Open one tap
Turn on pump
Close tap once water begins flowing
Open each additional tap until all air has
been purged from system
Pump will shut off after taps are closed
and pressure builds to the set point of the
pressure switch
Self-priming
Pump is self-priming up to 6 ft (2m). Intake lines
must be air-tight to ensure self-priming.
Dry running
Pump will not be damaged by shorter period
of dry running. It will, however, unnecessarily
reduce your battery power.
CAUTION: Do not use pump for any liquids other
than fresh water and sea water.
Temperature
Max liquid temperature: +120°F (+50°C)
Max ambient temperature: +140°F (+60°C)
Winterizing
If water is not drained from the system during
freezing temperatures, damage is likely to be
sustained in the plumbing and in the pump. To
prevent damage follow the instructions below:
1. Drain water storage tank.
2. Open all taps.
3. Run pump until remaining water is expelled.
4. Disconnect inlet and outlet tubes.
5. Run pump briefly to confirm that
water has been expelled.
6. Taps shall remain open and pump fittings shall
remain disconnected until temperatures are
above freezing.
Never start a frozen pump. Even if it is drained
it might contain a small amount of frozen water
that locks the rotor.
Accessory
Model 7923667 Universal Strainer
ENGLISH
WPS2_4-InstructManual.indd 5 2/16/06 7:55:01 PM
6
Symptom
Pump does not run.
Pump does not prime.
Pump cycles on and off rapidly
while water is demanded.
Pump cycles on and off rapidly
while water is not demanded.
Pump will not stop running when
water is not demanded.
Low flow/pressure.
Pump is excessively noisy.
Trouble-shooting chart
Cause
1. Tripped thermal protector
or blown fuse.
2. Faulty wire connection or
power source.
3. Pressure switch malfunctioning.
4. Motor malfunctioning.
5. Pump/motor frozen.
1. Water tank empty.
2. Debris under valves.
3. Perforated diaphragm.
4. Leak on inlet side of pump.
5. Inlet or outlet plumbing restricted.
Restriction on outlet side of pump/
too high pressure.
Leak on outlet side of pump.
1. Leak on inlet side of pump.
2. Leak on outlet side of pump.
3. Perforated diaphragm.
4. Water tank empty.
5. Pressure switch malfunctioning.
6. Low voltage to pump.
1. Leak on inlet side of pump.
2. Leak on outlet side of pump.
3. Perforated diaphragm.
4. Motor malfunction.
5. Debris under valves.
1. Pump is plumbed directly to
rigid tubing.
2. Pump head loose on motor.
3. Pump mounting is loose.
4. Pump mounting is too rigid.
5. Defective motor.
Remedy
1. Check fuse. If motor is overheated let
it cool down prior to restart.
2. Check battery/power supply, main
switch and wiring.
3. Change pressure switch.
4. Change pump.
5. Thaw pump and system and check for
damage. The pump/motor is liable to
damage when a frozen pump is started.
1. Fill up tank.
2. Carefully flush pump with tap water
at nominal pump flow.
Note: Flush in
nominal flow direction.
3. Replace pump head kit.
4. Check tightness of hose connections
at pump, filter and tank.
5. Check plumbing.
Outlet hose too small, must be of
same diameter as pump connection.
Check tightness of hose connections,
check hose for possible damage.
1. Check tightness of hose connections,
check hose for possible damage.
2. Check tightness of hose connections,
check hose for possible damage.
3. Replace pump head kit.
4. Fill up tank.
5. Change pressure switch.
6. Change battery/power supply.
1. Check tightness of hose connections,
check hose for possible damage.
2. Check tightness of hose connections,
check hose for possible damage.
3. Replace pump head kit.
4. Change pump.
5. Carefully flush pump with tap water
at nominal pump flow.
Note: Flush in
nominal flow direction.
1. Install flexible tubing according to
installation recommendation, see pg. 4
2. Tighten screws.
3. Tighten screws.
4. Use flexible tubing and make sure the
dampening rubber feet are used.
5. Change pump.
ENGLISH
WPS2_4-InstructManual.indd 6 2/16/06 7:55:01 PM
7
Model 7865645 Pompe d'eau sous-pression 2.4
12V pompe à diaphragme à déplacement positif avec cinq chambres.
Applications typiques
Cette pompe est idéale pour l’eau sous pression
dans un système fermé comme sur un bateau ou
sur un véhicule de plaisance.
Elle peut fournir facilement la pression demandée
pour un système d’alimentation en eau sous
pression.
Propriétés
Fonctionnement silencieux
Débit régulier
Auto-amorçage
Un capteur de pression intégré arrête et met la
pompe automatiquement en service lorsque le
robinet est fermé et ouvert.
Fonctionnement à sec sans danger
Faible consommation électrique
Raccords rapides
Principe de travail
Lorsque la pompe travaille, la pression monte
jusqu’à 2,8 bars/41 psi. A ce point, le contact de
pression intégré arrête automatiquement la pompe.
La pompe est équipée de vannes de contrôle à la
sortie qui vérifient que la pression est maintenue
après l’arrêt de la pompe.
En soutirant de l’eau (pour les toilettes, la douche),
la pression diminue. Après une baisse modérée de
la pression, le contact de pression intégré remet
automatiquement la pompe en service.
Grâce à sa construction robuste et son design bien
étudié, la pompe travaille sans problème pendant
de nombreuses années.
Important: Le réglage de la pression de cette
pompe est fait d’usine. La garantie perd toute
validité si le contact de pression est touché.
Caractéristiques
Corps: Polypropylène
Boîtier de vanne: Polyamide
Vannes: EPDM
Diaphragme: Santoprène
Raccord: ISO228/1-G
3/8" BSP, flexible de
1/2" (13mm) et
1/2" BSP, flexible de
3/4" (19mm)
Température de liquide: Maxi. +50°C
Fixations: Acier inoxydable
Hauteur maxi. d’aspiration: 2 m
Pression d’enclenchement: 1,7 bar/25 Psi
Pression de coupure: 2,8 bar/41 Psi
Cycle de fonctionnement: Intermittent
maxi. 20 min
Moteur: 87W, 12V DC
avec sécurité
thermique intégrée
Poids: 1.6kg
Le moteur et le contact sont antidéflagrant
conformément à la norme ISO 8846
(Equipements électriques de petits bateaux
dans un environnement de gaz inflammable).
Caractéristiques de pression
et de débit
Basées sur de l’eau à +20°C et avec une tension
maximale du moteur.
Pression Débit Intensité
Bar kPa Psi L/min USGPM 12V
0 0 0 9,4 2,4 2,5A
0,4 40 5,8 8,8 2,3 3,3A
0,8 80 11,6 8,1 2,1 4,0A
1,2 120 17,4 7,3 1,9 4,6A
1,6 160 23,2 6,7 1,8 5,2A
2,0 200 29 5,8 1,5 5,8A
2,4 240 34,8 4,9 1,3 6,4A
2,8 280 40,6 4,1 1,1 6,9A
Fusible nécessaire: 10A
FRANÇAIS
WPS2_4-InstructManual.indd 7 2/16/06 7:55:02 PM
8
Installation
Monter la pompe à un endroit sec.
1. Si la pompe est montée verticalement,
le moteur doit être tourné vers le haut.
2. Repérer la position des vis et prépercer
(voir le gabarit de perçage page 16).
3. Monter la pompe en utilisant des vis inoxydables
et en faisant attention à ne pas comprimer les
pieds amortisseurs en caoutchouc.
4. Il est recommandé d’utiliser un tuyau flexible ren
-
forcé spécial haute pression. Si un tuyau rigide
est utilisé, un tuyau flexible d’une longueur de
225 mm/9 pouces minimum devra être installé
entre la pompe et le tuyau rigide. Celui-ci va
empêcher les bruits et/ou les dégâts causés par
les vibrations d’être transmis au tuyau rigide.
5. Utiliser des colliers de serrage en acier inoxyd-
able pour fixer les tuyaux aux raccords rapides et
aux autres parties du système.
NOTE: Il faut monter le filtre á l’entrée de la pompe
pour empêcher les débris d’entrer dans la pompe
et entraîner des perturbations de fonctionnement
des vannes.
Installation électrique
1. La pompe doit être installée conformément à
la norme ISO 10133 (Petits bateaux, système
électrique, installation à courant continu de très
basse tension). Note: Le fusible doit être de type
”antidéflagrant”.
2. Le moteur est équipé d’une sécurité thermique
intégrée pour le protéger contre les surchauffes.
La protection est automatiquement réarmée
lorsque le moteur a refroidi.
3. Si un fil de terre séparé est raccordé à la pompe,
il doit être jaune/vert et branché à la base du
moteur. Voir le schéma de câblage pour une
installation exacte. Le fil négatif doit être noir.
4. Choisir une section de fil en fonction de la
longueur totale du fil (voir la page suivante).
5.Utiliser un produit d’étanchéité pour applications
marines aux raccords de fil.
Note: Avant l’installation des systèmes électriques
de commande, vérifier que l’équipement qui va être
utilisé a une puissance suffisante pour supporter le
courant demandé par le moteur. Une tension faible
entraîne une surchauffe du moteur.
Maintenance
Le système devra être vérifié périodiquement
conformément à ci-après:
1. Remplir la cuve avec une solution d’eau de
javel ménager et d’eau potable (1 ml de javel
par litre d’eau).
2. Ouvrir tous les robinets et faire fonctionner la
pompe jusqu’à ce que l’eau qui s’écoule sente
la javel.
3. Nettoyer tous les robinets.
4. Vider la solution de la cuve.
5. Remplir la cuve d’eau potable.
6. Ouvrir tous les robinets et faire fonctionner la
pompe jusqu’à ce que tout le produit javelisant
soit éliminé.
Section des fils
(basée sur une chute de tension de 10%)
Pompe
Fusible
principal
Maxi. 0,2 m
Rouge
Noir
Vert/jaune
+
Les autres équipements électriques, comme
un coupe-cirucit, doivent être installés entre
la pompe et le fil positif (+) de la batterie
(sur le fil rouge).
Schéma de câblage
* La longueur de fil correspond à la distance totale
entre la batterie et la pompe et le retour à la bat-
terie. Il est recommandé d’utiliser un relais avec
un fil léger partant du fil principal à l’interrupteur
pour raccourcir les fils principaux.
Longueur de fil*
Section de fil maxi.en m
1,0 mm
2
(18 GA) 11.9
1,5 mm
2
(16 GA) 17.9
2.5 mm
2
(14 GA) 29.8
FRANÇAIS
WPS2_4-InstructManual.indd 8 2/16/06 7:55:02 PM
9
Rien n’est plus important pour nous que la satisfaction des clients.
Si vous avez des questions ou si le produit que vous avez acheté
ne satisfait pas vos attentes, veuillez nous contacter par une des
méthodes suivantes:
Contactez le magasin West Marine près de chez vous
Téléphonez au 1-800-BOATING
Visitez-nous à: www.westmarine.com
En hiver
Si l’eau n’est pas vidangée du système lorsque les
températures extérieures descendent en dessous
de zéro, les conduites et la pompe seront endom-
magées. Pour éviter ces inconvénients, procéder
de la façon suivante:
1. Vider la cuve de stockage d’eau.
2. Ouvrir tous les robinets.
3. Faire fonctionner la pompe jusqu’à ce
que toute l’eau restante soit évacuée.
4. Débrancher les conduites d’arrivée
et de sortie.
5. Faire tourner brièvement la pompe
pour vérifier que toute l’eau a bien
été évacuée.
6. Laisser les robinets ouverts et les
raccords de pompe débranchés
jusqu’à ce que les températures
soient remontées au-dessus de zéro.
Ne jamais démarrer une pompe gelée. Même
si elle a été vidangée, elle peut contenir de très
petites quantités d’eau gelée qui vont bloquer
le moteur.
Accessoire
Model 7923667 Tamis universal
Procédure de mise en service
Après l’installation de la pompe, le système peut
être mis en service en suivant la procédure ci-après:
Remplir la cuve d’eau
Ouvrir un robinet
Mettre la pompe en service
Fermer le robinet lorsque l’eau commence
à couler.
Ouvrir tous les robinets les uns après les autres
pour purger tout l’air contenu dans le système.
La pompe va s’arrêter lorsque tous les robinets
sont fermés et que la pression aura atteint le
niveau réglé pour le contact de pression.
Auto-amorçage
La pompe est auto-amorçante jusqu’à 2 m. Les
conduites d’arrivée doivent être étanches à l’air
pour assurer l’auto- amorçage.
Fonctionnement à sec
La pompe ne sera pas endommagée par une courte
période de fonctionnement à sec. Elle va cependant
réduire inutilement la puissance de votre batterie.
ATTENTION: N’utilisez pas la pompe pour d’autres
liquides que de l’eau douce et de l’eau de mer.
Température
Température maxi. du liquide: +50°C
Température ambiante maxi.: +60°C
FRANÇAIS
WPS2_4-InstructManual.indd 9 2/16/06 7:55:03 PM
10
Plan de recherche de pannes
Symptôme
La pompe ne fonctionne pas.
Pas d’auto-amorçage de
la pompe.
Cycles de pompe trop rapides
en soutirant de l’eau.
Cycles de pompe trop rapides
sans soutirer de l’eau.
La pompe ne s’arrête pas sans
soutirer de l’eau.
Débit/pression insuffisants
Pompe excessivement bruyante.
Cause
1. Sécurité thermique ou fusible
déclenchés.
2. Fil ou alimentation incorrectement
branchés.
3. Contact de pression défectueux.
4. Moteur défectueux.
5. Pompe/moteur gelés.
1. Cuve d’eau vide.
2. Dépôts sous les vannes.
3. Diaphragme perforé.
4. Fuites sur le côté aspiration de
la pompe.
5. Etranglement sur les conduites
d’entrée ou de sortie.
Etranglement du côté refoulement
de la pompe/pression trop élevée.
Fuites du côté aspiration de
la pompe.
1. Fuites du côté aspiration de
la pompe.
2. Fuites du côté refoulement de
la pompe.
3. Diaphragme perforé.
4. Cuve d’eau vide.
5. Contact de pression défectueux.
6. Faible tension à la pompe.
1. Fuites du côté aspiration de
la pompe.
2. Fuites du côté refoulement de
la pompe.
3. Diaphragme perforé.
4. Moteur défectueux.
5. Dépôts sous les vannes.
1. La pompe est montée directement
à une conduite rigide.
2. La tête de pompe se détache
du moteur.
3. La pompe est desserrée
4. La pompe est montée trop serrée.
4. Moteur défectueux.
Remède
1. Vérifier le fusible. Si la sécurité thermique
s’est déclenchée, laisser refroidir le
moteur avant de redémarrer.
2. Vérifier la batterie/l’alimentation,
l’interrupteur principal et le câblage.
3. Remplacer le contact de pression.
4. Remplacer la pompe.
5. Dégeler la pompe et le système, vérifier
les dégâts. La pompe/moteur peuvent
être endommagés en démarrant une
pompe gelée.
1. Remplir la cuve.
2. Avec précautions, rincer la pompe avec
de l’eau du robinet à un débit normal
de pompe. Note! rincer dans le sens de
passage normal de l’eau.
3. Remplacer le kit de pompe complet.
4. Vérifier le serrage des raccords de
flexible sur la pompe, le filtre et la cuve.
5. Vérifier les conduites.
Le flexible de sortie est trop petit, il doit avoir
le même diamètre que le raccord de pompe.
Vérifier le serrage des raccords de flexible,
vérifier le flexible au point de vue dégâts.
1. Vérifier le serrage des raccords de flexible,
vérifier le flexible au point de vue dégâts.
2. Vérifier le serrage des raccords de
flexible, vérifier le flexible au point de
vue dégâts.
3. Remplacer le kit de pompe complet.
4. Remplir la cuve.
5. Remplacer le contact de pression.
6. Remplacer la batterie/tension
d’alimentation.
1. Vérifier le serrage des raccords de
flexible, vérifier le flexible au point de
vue dégâts.
2. Vérifier le serrage des raccords de
flexible, vérifier le flexible au point de
vue dégâts.
3. Remplacer le kit de pompe complet.
4. Remplacer la pompe.
5. Avec précautions, rincer la pompe avec
de l’eau du robinet à un débit normal de la
pompe. Note! rincer dans le sens normal
de passage d’eau.
1. Monter un flexible conformément aux
recommandations d’installation, page 8.
2. Serrer les vis.
3. Serrer les vis.
3. Utiliser un flexible et s’assurer que les
pieds amortisseurs en caoutchouc sont
bien utilisés.
4. Remplacer la pompe.
FRANÇAIS
WPS2_4-InstructManual.indd 10 2/16/06 7:55:03 PM
11
Plan de recherche de pannes
Aplicaciones típicas
Esta bomba es la elección adecuada para la presur-
ización de agua en sistemas cerrados, tales como
los de los barcos o los de las autocaravanas.
La bomba proporciona la presión necesaria para el
suministro de agua a presión.
Características
Funcionamiento silencioso
Flujo de caudal uniforme
Autocebado
El interruptor de presión integrado enciende
y apaga la bomba automáticamente al abrir o
cerrar el grifo
Funcionamiento en seco sin daños
Bajo consumo
Conexiones de empalme rápido
Principios de funcionamiento
Cuando la bomba está funcionando, el sistema
produce presión hasta alcanzar los 2,8 bares/41psi.
Una vez se ha llegado a este valor,el interruptor
integrado cierra automáticamente la bomba.
La bomba está equipada con válvulas de salida de
control positivo, las cuales aseguran el manten-
imiento de la presión una vez se ha desconectado
la bomba.
Cuando se dispone de agua (en los grifos, la
ducha, etc.) la presión disminuye. Después de una
moderada caída de presión, el presostato integrado
pone de nuevo en funcionamiento la bomba.
Gracias a su robusta construcción y al cuidado
diseño, la bomba proporciona una larga vida de
servicio.
¡Advertencia! La configuración y ajuste de los
valores de presión de esta bomba se realiza en
fábrica. La garantía quedará invalidada en caso
de que se manipule el interruptor de presión.
Especificaciones
Cuerpo: Polipropileno
Alojamiento de válvula: Polyamide
Válvulas: EPDM
Membrana: Santopreno
Conexión: ISO228/1-G
3/8" BSP, tubo de
1/2" (13mm) et
1/2" BSP, tubo de
3/4" (19mm)
Temperatura del líquido: Max.+50 °C
Sujeciones: Acero inoxidable
Altura máxima
de aspiración: 2 m
Presión de arranque: 1,7 bar/25 Psi
Presión de paro: 2,8 bar/41 Psi
Ciclo de trabajo: Intermitente
20 minutos máximo
Motor: 87 W, 12V DC
con protección de
sobrecalentamiento
incorporada
Peso: 2 kg
Motor y interruptor con protección de encendido
según ISO 8846 (Pequeñas embarcaciones –
Artículos eléctricos – Antideflagrante en ambientes
de gases inflamables).
Model 7865645 Bomba de presión de agua 2.4
12V bomba de membrana con desplazamiento positivo de cinco cámaras.
Datos de presión y caudal
Basados en agua a 20 °C y motor a plena tensión.
Presión Caudal Amperaje
Bar kPa Psi L/mn USGPM 12V
0 0 0 9,4 2,4 2,5A
0,4 40 5,8 8,8 2,3 3,3A
0,8 80 11,6 8,1 2,1 4,0A
1,2 120 17,4 7,3 1,9 4,6A
1,6 160 23,2 6,7 1,8 5,2A
2,0 200 29 5,8 1,5 5,8A
2,4 240 34,8 4,9 1,3 6,4A
2,8 280 40,6 4,1 1,1 6,9A
Fusible necesario: 10A
ESPAÑOL
WPS2_4-InstructManual.indd 11 2/16/06 7:55:04 PM
12
Instalación
Situar la bomba en un lugar seco.
1. Si la bomba se instala en sentido vertical,el
motor deberá estar hacia arriba.
2. Marcar la posición de los tornillos y perforar los
orificios guía (ver la plantilla de perforación en
la página 16).
3. Montar la bomba usando tornillos de acero
inoxidable, teniendo cuidado de no sobrecom-
primir los soportes de goma amortiguadores
de vibraciones.
4. Se recomienda el uso de tuberías flexibles
reforzadas para alta presión. Si se utiliza
tubería rígida, deberá instalarse un tramo (mín.
229mm/9 pulgadas) de tubería flexible entre la
bomba y la tubería rígida. Esta medida evitará el
ruido y/o los daños causados por las vibraciones
a la tubería rígida.
5. Utilizar abrazaderas de acero inoxidable para
acoplar la tubería a las conexiones de empalme
rápido y a otros tubos del sistema.
¡NOTA!
El filtro debe ser instalado en la línea de
aspiración inmediatamente antes de la entrada
de la bomba, para prevenir la entrada de residuos
en la bomba y las interferencias en el funciona-
miento adecuado de las válvulas.
Instalación eléctrica
1. La bomba deberá instalarse según las nomas
ISO 10133 (Pequeñas embarcaciones –
Artículos eléctricos – Bajo voltaje de CC para
funcionamiento continuo). Nota: El fusible debe
ser antideflagrante.
2. El motor tiene incorporado un dispositivo para
evitar el sobrecalentamiento. El funcionamiento
se restablece automáticamente cuando el motor
se enfría.
3. Si la bomba se instala con toma de tierra, se
utilizará un cable amarillo/ verde y se conectará
a la base del motor.
4. Para la instalación correcta del mismo, ver el
esquema eléctrico en la página siguiente. El
cable negativo deberá ser decolor negro. Instalar
la sección de cableque corresponda según la
longitud totaldel cable .
5. Todas las conexiones con cable eléctrico deben
sellarse con un compuesto para aplicaciones
marinas.
¡Nota! En las instalaciones con interruptor
automático de protección deberá comprobarse
que la unidad a utilizar tiene lacapacidad nominal
necesaria parasoportar el amperaje del motor. La
baja tensión produce recalentamiento del motor.
Tabla de cables
(basada en una caída de voltaje del 10%)
Long. máx*de
Sección cable cable en metros
1,0 mm
2
(18 GA) 11.9
1,5 mm
2
(16 GA) 17.9
2.5 mm
2
(14 GA) 29.8
* La longitud de cable es la distancia total desde
la batería hasta la bomba y regreso a la batería.
Se recomienda usar un relé con un hilo eléctrico
que vaya desde el cable principal al interruptor
para acortar los conductores principales.
El resto de los dispositivos eléctricos, es decir, el
interruptor, el conmutador de circuito, deberán
instalarse entre la bomba y el polo positivo de la
batería (en el cable rojo).
Bomba
Fusible
principal
Maxi. 0,2 m
Rojo
Negro
Verde/amarillo
+
Esquema eléctrico
ESPAÑOL
Mantenimiento
El sistema debe sanearse periódica-mente, según
las instrucciones siguientes:
1. Llenar el depósito con una solución de lejía
doméstica y agua potable (1 ml de lejía por
litro de agua).
2. Abrir todos los grifos y dejar correr el agua
hasta que el flujo de agua huela a lejía.
3. Cerrar todas los grifos.
4. Vaciar el tanque con la solución de agua y lejía.
5. Rellenar el depósito con agua potable.
6. Abrir todas los grifos y dejar correr el agua
hasta que se haya purgado la lejía.
WPS2_4-InstructManual.indd 12 2/16/06 7:55:04 PM
13
Para nosotros no hay nada más importante que la satisfacción del
cliente. Si tiene alguna pregunta o si su compra no está a la altura
de sus expectativas, siga una de las siguientes opciones:
Póngase en contacto con su tienda local de West Marine
Llame al 1-800-BOATING
Póngase en contacto con nosotros en www.westmarine.com
Instrucciones de arranque
Una vez realizada la instalación de la bomba,
seguir las siguientes instrucciones para el
arranque del sistema:
Llenar el depósito de agua
Abrir un grifo
Encender la bomba
Cerrar el grifo una vez el agua empieza a fluir
Abrir los grifos adicionales hasta que se haya
purgado todo el aire del sistema
La bomba se apagará una vez cerrados todos los
grifos y se haya alcanzado una presión equiva-
lente al valor de cierre del interruptor de presión
Autocebado
La bomba se ceba automáticamente hasta un
máximo de 2m de altura. Las líneas de aliment-
ación deben ser herméticas para garantizar
el autocebado.
Funcionamiento en seco
La bomba no se verá dañada si funciona en seco
durante un corto periodo de tiempo. Aunque al
funcionar en seco se reducirá innecesariamente la
carga de la batería.
PRECAUCIÓN: No utilizar la bomba con otros
líquidos que no sea agua dulce o agua de mar.
Temperatura
Temperatura máx.de líquidos:+ 50 °C
Temperatura máx.ambiente: +60 °C
Protección contra
los agentes invernales
Si no se vacía el agua del sistema durante
épocas con temperaturas bajo cero, es probable
que el sistema de tuberías y la bomba sufran
daños. Para evitar daños de este tipo, seguir las
siguientes instrucciones:
1. Drenar el depósito de almacenamiento de agua.
2. Abrir todos los grifos.
3. Hacer funcionar la bomba hasta que se haya
expulsado toda el agua.
4. Desconectar los tubos de entrada y los tubos
de salida.
5. Hacer funcionar la bomba para confirmar que
se ha expulsado la totalidad del agua.
6. Los grifos deberán permanecer abiertos y
las conexiones de la bomba desacopladas
hasta que la temperatura sea superior al punto
de congelación del agua.
No arrancar nunca una bomba que esté congelada.
A pesar deque haya sido drenada, podría contener
pequeñas cantidades de hielo que bloquearían el
motor.
Accesorio
Model 7923667 Tamiz universal
ESPAÑOL
WPS2_4-InstructManual.indd 13 2/16/06 7:55:05 PM
14
Síntoma
La bomba no funciona.
La bomba no realiza la operacíon
de cebado.
La bomba se detiene y se ponen en
marcha repetidas veces cuando se
necesita agua.
La bomba se detiene y se pone
en marcha repetidas veces cuando
se necesita agua.
La bomba no se detiene cuando no
se necesita agua.
Flujo bajo/baja presión.
La bomba hace demasiado.
Tabla de localización de averías
Causa
1. Protector térmico desconectado o
fusible fundido.
2. Conexión defectuosa de cable o de
fuente de suministro de energía.
3. Avería en el interruptor de presión.
4. Avería en el motor.
5. Bomba/motor congelados.
1. Depósito de agua vacío.
2. Residuos debajo de las válvulas.
3. Membrana perforada.
4. Pérdida en el lado de entrada de
la bomba.
5. Tuberías de entrada o salida
con restricciones.
Restricciones en el lado de salida de
la bomba; presión demasiado alta.
Pérdida en el lado de salida de
la bomba.
1. Pérdida en el lado de entrada de
la bomba.
2. Pérdida en el lado de salida de
la bomba.
3. Diagrama perforado.
4. Depósito de agua vacío.
5. El interruptor de presión funciona
defectuosamente.
6. Tensión baja a la bomba.
1. Pérdida en el lado de entrada de
la bomba.
2. Pérdida en el lado de salida de
la bomba.
3. Diagrama perforado.
4. Motor averiado.
5. Residuos debajo de las válvulas.
1 La bomba está acoplada/soldada
directamente a la tubificación rígida.
2. El cabezal de la bomba está suelto en
el motor.
3. Los tornillos de la bomba están flojos.
4. El montaje de la bomba es
demasiado rígido.
5. Motor defectuoso.
Medida
1. Controlar fusible. Si el motor está
sobrecalentado, dejar que se enfríe
antes de ponerlo en marcha.
2. Controlar batería/fuente de sumistro de
energía, interruptor principal y cables.
3. Cambiar interruptor de presión.
4. Cambiar bomba.
5. Descongelar el motor y el sistema
y controlar los posibles daños. La
bomba/el motor pueden quedar daña-
dos al arrancar una bomba congelada.
1. Llenar el depósito.
2. Limpiar, cuidadosamente, la bomba
con agua del grifo al flujo de bombeo
nominal. ¡Nota! Limpiar en la direccíon
de bombeo nominal.
3. Cambiar el juego de bomba.
4. Controlar que la estanqueidad de
las conexiones a la bomba, el filtro
y el depósito.
5. Controlar las tuberías.
Tubo de salida demasiado estrecho; debe
tener el mismo diámetro que la conexión.
Controlar la estanqueidad de las
conexiones de los tubos; controlar
posibles daños en los tubos.
1. Controlar la estanqueidad de las
conexiones de los tubos; controlar
posibles daños en los tubos.
2. Controlar la estanqueidad de las
conexiones de los tubos; controlar
posibles daños en los tubos.
3. Cambiar el juego de bomba.
4. Llenar el depósito.
5. Cambiar el interruptor de presión.
6. Cambiar la batería/suministro
de energía.
1. Controlar la estanqueidad de las
conexiones de los tubos; controlar
posibles daños en los tubos.
2. Controlar la estanqueidad de las
conexiones de los tubos; controlar
posibles daños en los tubos.
3. Cambiar el juego de bomba.
4. Cambiar la bomba.
5. Limpiar, cuidadosamente, la bomba
con agua del grifo al flujo de bombeo
nominal. ¡Nota! Limpiar en la dirección
de bombeo nominal.
1. Instalar tubificación flexible según
las recomendaciones de montaje,
ver página 12.
2. Apretar los tornillos.
3. Apretar los tornillos.
4. Usar tubificación flexible y comprobar
que se usan los pies amortiguadores
de goma.
5. Cambiar la bomba.
ESPAÑOL
WPS2_4-InstructManual.indd 14 2/16/06 7:55:05 PM
15
Dimensions mm/inches
Dimensions mm/pouces
Dimensiones mm/pulgadas
65 / 2.559 57 / 2.244
202 / 7.593
197 / 7.56
111 / 4.37
81 / 3.189
74 / 2.913
WPS2_4-InstructManual.indd 15 2/16/06 7:55:06 PM
16
Hole layout 1:1
Schéma de perçage 1:1
Croquis agujeros 1:1
57 mm
2.244 inch
81 mm
3.189 inch
500 Westridge Dr.
Watsonville, CA 95076
Made in USA
www.westmarine.com
WPS2_4-InstructManual.indd 16 2/16/06 7:55:07 PM

Transcripción de documentos

FRANÇAIS Water Pressure Pump 2.4 Instruction Manual Manuel d’instruction • Manual de instrucción WPS2_4-InstructManual.indd 1 2/16/06 7:54:59 PM Contents • Contenu • Contenido English Français Español 3 7 11 Recreational Craft Directive 94/25/EEC ISO 8849: 1990/Electrical operated bilge pumps ISO 8846: 1990/Electrical devices - Protection against ignition of surrounding flammable gases ISO 10133: 1994/Electrical systems - Extra low-voltage DC installations Electromagnetic Compatibility Directive 89/336/EEC EN55014: 1993/Radio Disturbance Made in the USA 2 WPS2_4-InstructManual.indd 2 2/16/06 7:54:59 PM ENGLISH Model 7865645 Water Pressure Pump 2.4 12V DC five chamber positive displacement diaphragm pump. Typical applications This pump is the ideal choice for pressurizing water in a closed system such as that found in a boat or in a recreational vehicle. It can easily build the pressure required for a pressurized water supply system. Features • • • • Quiet operation Smooth flowing Self priming Integrated pressure switch turns pump on and off automatically when tap is opened and closed • Dry running without damage • Low power consumption • Quick disconnect fittings Working principle As the pump runs, pressure builds until reaching 2.8 bar/41 psi. At this point, the integrated pressure switch automatically shuts the pump off. The pump is equipped with positively checking outlet valves which ensure that the pressure is maintained after the pump shuts off. When water is demanded (at the faucet, shower, etc.) the pressure decreases. After a moderate drop in pressure, the integrated pressure switch automatically turns the pump back on. Due to it’s durable construction and thoughtful design, the pump will provide many years of service. Important! The pressure setting of this pump is made at the factory. Warranty invalidated by pressure switch interference. Specifications Body: Valve housing: Valves: Diaphragm: Connection: Polypropylene Polyamide EPDM Santoprene ISO228/1-G 3/8" NPT, 1/2" (13mm) hose and 1/2" NPT, 3/4" (19mm) hose Liquid temperature: Max. +120°F (+50°C) Fasteners: Stainless steel Max. suction lift: 6.5 ft (2m) Cut in pressure: 1.7 Bar/25 psi Cut-off pressure: 2.8 Bar/41 psi Duty cycle: Intermittent, max 20 min Motor: 87W, 12V DC with built in thermal protection Weight: 3.5 lb (1.6kg) The motor and switch are ignition protected according to ISO 8846 (Small craft – Electrical devices – Protection against ignition of surrounding flammable gases). Pressure and capacity data Based on water at 68°F (+20°C) and at full voltage of the motor. Amperage Pressure Flow draw Bar kPa Psi L/min GPM 12V 0 0 0 9.4 2.4 2.5A 0.4 40 5.8 8.8 2.3 3.3A 0.8 80 11.6 8.1 2.1 4.0A 1.2 120 17.4 7.3 1.9 4.6A 1.6 160 23.2 6.7 1.8 5.2A 2.0 200 29 5.8 1.5 5.8A 2.4 240 34.8 4.9 1.3 6.4A 2.8 280 40.6 4.1 1.1 6.9A Fuse required: 10A 3 WPS2_4-InstructManual.indd 3 2/16/06 7:54:59 PM ENGLISH Installation Wiring table Locate the pump in a dry location. 1. If the pump is mounted vertically, the motor shall face up. 2. Mark screw positions and drill pilot holes (see drilling template page 16). 3. Mount the pump using stainless steel screws taking care not to over compress the vibration dampening rubber feet. 4. Reinforced, high-pressure flexible tubing is recommended. If rigid pipe is used, a length (minimum 9"/225 mm) of flexible tubing shall be installed between the pump and the rigid pipe. This will address noise and/or damage caused by vibration transmitted to rigid pipe. 5. Use stainless steel hose clamps to secure tubing to quick disconnect fittings and other hose barbs in the system. NOTE: The strainer must be installed in line before the pump intake, to prevent debris from entering pump and interfering with proper functioning of valves. Electrical installation 1. The pump must be installed according to SS-EN ISO 10133 (Small craft – Electrical system – Extra low voltage DC installation for continous current). Note: The fuse must be ignition protected. 2. The motor is equipped with built in thermal protection to prevent the motor from overheating. The protection is automatically restored when the motor is cooled. 3. If the pump is connected with separate earth lead, this should be yellow/green and connected to the motor base. 4. See the wiring table for correct installation. Negative wire must be black. Choose wire size in accordance with total wire length. 5. The wire connections must be sealed with a marine sealant. NOTE: Before installation with electrical control systems, check that equipment to be used is of sufficient rated capacity to accept amperage draw of motor. Low voltage will cause motor to overheat. Max 8" (0.2m) Red – + Terminal fuse Black Pump Green/yellow Other electrical devices, e.g. switch, circuit breaker, must be installed between the pump and the positive (+) lead on the battery (on the red wire). Wiring dimensions (based on 10% voltage drop) Wire size 18 GA 16 GA 14 GA (1.0 mm2) (1.5 mm2) (2.5 mm2) Max wire length* in m 11.9 17.9 29.8 * The wire length is the total distance from the battery to the pump and back to the battery. It is recommended to use a relay with a light wire from main cable to switch to shorten the main leaders. Maintenance The system shall be periodically sanitized using the following procedure: 1. Fill the tank with a solution of household bleach and potable watern .03 oz. (1ml) bleach to 32 oz. (1 L) water. 2. Open all faucets and run until water flowing smells of bleach. 3. Close all faucets. 4. Drain solution from tank. 5. Refill tank with potable water. 6. Open all faucets and run until bleach has been purged. 4 WPS2_4-InstructManual.indd 4 2/16/06 7:55:00 PM ENGLISH Start-up procedure Winterizing After pump installation, the system can be started by using the following procedure: • Fill water tank • Open one tap • Turn on pump • Close tap once water begins flowing • Open each additional tap until all air has been purged from system • Pump will shut off after taps are closed and pressure builds to the set point of the pressure switch If water is not drained from the system during freezing temperatures, damage is likely to be sustained in the plumbing and in the pump. To prevent damage follow the instructions below: 1. Drain water storage tank. 2. Open all taps. 3. Run pump until remaining water is expelled. 4. Disconnect inlet and outlet tubes. 5. Run pump briefly to confirm that water has been expelled. 6. Taps shall remain open and pump fittings shall remain disconnected until temperatures are above freezing. Never start a frozen pump. Even if it is drained it might contain a small amount of frozen water that locks the rotor. Self-priming Pump is self-priming up to 6 ft (2m). Intake lines must be air-tight to ensure self-priming. Dry running Pump will not be damaged by shorter period of dry running. It will, however, unnecessarily reduce your battery power. Accessory Model 7923667 Universal Strainer CAUTION: Do not use pump for any liquids other than fresh water and sea water. Temperature Max liquid temperature: +120°F (+50°C) Max ambient temperature: +140°F (+60°C) There’s nothing more important to us than customer satisfaction. If you have any questions or your purchase does not meet your expectations, please do one of the following: • Contact your local West Marine store • Call 1-800-BOATING • Contact us at www.westmarine.com 5 WPS2_4-InstructManual.indd 5 2/16/06 7:55:01 PM ENGLISH Trouble-shooting chart Symptom Cause Remedy Pump does not run. 1. Tripped thermal protector or blown fuse. 2. Faulty wire connection or power source. 3. Pressure switch malfunctioning. 4. Motor malfunctioning. 5. Pump/motor frozen. 1. Check fuse. If motor is overheated let it cool down prior to restart. 2. Check battery/power supply, main switch and wiring. 3. Change pressure switch. 4. Change pump. 5. Thaw pump and system and check for damage. The pump/motor is liable to damage when a frozen pump is started. Pump does not prime. 1. Water tank empty. 2. Debris under valves. 5. Inlet or outlet plumbing restricted. 1. Fill up tank. 2. Carefully flush pump with tap water at nominal pump flow. Note: Flush in nominal flow direction. 3. Replace pump head kit. 4. Check tightness of hose connections at pump, filter and tank. 5. Check plumbing. Pump cycles on and off rapidly while water is demanded. Restriction on outlet side of pump/ too high pressure. Outlet hose too small, must be of same diameter as pump connection. Pump cycles on and off rapidly while water is not demanded. Leak on outlet side of pump. Check tightness of hose connections, check hose for possible damage. Pump will not stop running when water is not demanded. 1. Leak on inlet side of pump. 1. Check tightness of hose connections, check hose for possible damage. 2. Check tightness of hose connections, check hose for possible damage. 3. Replace pump head kit. 4. Fill up tank. 5. Change pressure switch. 6. Change battery/power supply. 3. Perforated diaphragm. 4. Leak on inlet side of pump. 2. Leak on outlet side of pump. 3. Perforated diaphragm. 4. Water tank empty. 5. Pressure switch malfunctioning. 6. Low voltage to pump. Low flow/pressure. 1. Leak on inlet side of pump. 2. Leak on outlet side of pump. 3. Perforated diaphragm. 4. Motor malfunction. 5. Debris under valves. Pump is excessively noisy. 1. Pump is plumbed directly to rigid tubing. 2. Pump head loose on motor. 3. Pump mounting is loose. 4. Pump mounting is too rigid. 5. Defective motor. 1. Check tightness of hose connections, check hose for possible damage. 2. Check tightness of hose connections, check hose for possible damage. 3. Replace pump head kit. 4. Change pump. 5. Carefully flush pump with tap water at nominal pump flow. Note: Flush in nominal flow direction. 1. Install flexible tubing according to installation recommendation, see pg. 4 2. Tighten screws. 3. Tighten screws. 4. Use flexible tubing and make sure the dampening rubber feet are used. 5. Change pump. 6 WPS2_4-InstructManual.indd 6 2/16/06 7:55:01 PM FRANÇAIS Model 7865645 Pompe d'eau sous-pression 2.4 12V pompe à diaphragme à déplacement positif avec cinq chambres. Applications typiques Cette pompe est idéale pour l’eau sous pression dans un système fermé comme sur un bateau ou sur un véhicule de plaisance. Elle peut fournir facilement la pression demandée pour un système d’alimentation en eau sous pression. Propriétés • • • • Fonctionnement silencieux Débit régulier Auto-amorçage Un capteur de pression intégré arrête et met la pompe automatiquement en service lorsque le robinet est fermé et ouvert. • Fonctionnement à sec sans danger • Faible consommation électrique • Raccords rapides Principe de travail Lorsque la pompe travaille, la pression monte jusqu’à 2,8 bars/41 psi. A ce point, le contact de pression intégré arrête automatiquement la pompe. La pompe est équipée de vannes de contrôle à la sortie qui vérifient que la pression est maintenue après l’arrêt de la pompe. En soutirant de l’eau (pour les toilettes, la douche), la pression diminue. Après une baisse modérée de la pression, le contact de pression intégré remet automatiquement la pompe en service. Grâce à sa construction robuste et son design bien étudié, la pompe travaille sans problème pendant de nombreuses années. Important: Le réglage de la pression de cette pompe est fait d’usine. La garantie perd toute validité si le contact de pression est touché. Caractéristiques Corps: Boîtier de vanne: Vannes: Diaphragme: Raccord: Polypropylène Polyamide EPDM Santoprène ISO228/1-G 3/8" BSP, flexible de 1/2" (13mm) et 1/2" BSP, flexible de 3/4" (19mm) Température de liquide: Maxi. +50°C Fixations: Acier inoxydable Hauteur maxi. d’aspiration: 2m Pression d’enclenchement: 1,7 bar/25 Psi Pression de coupure: 2,8 bar/41 Psi Cycle de fonctionnement: Intermittent maxi. 20 min Moteur: 87W, 12V DC avec sécurité thermique intégrée Poids: 1.6kg Le moteur et le contact sont antidéflagrant conformément à la norme ISO 8846 (Equipements électriques de petits bateaux dans un environnement de gaz inflammable). Caractéristiques de pression et de débit Basées sur de l’eau à +20°C et avec une tension maximale du moteur. Pression Débit Intensité Bar kPa Psi L/min USGPM 12V 0 0 0 9,4 2,4 2,5A 0,4 40 5,8 8,8 2,3 3,3A 0,8 80 11,6 8,1 2,1 4,0A 1,2 120 17,4 7,3 1,9 4,6A 1,6 160 23,2 6,7 1,8 5,2A 2,0 200 29 5,8 1,5 5,8A 2,4 240 34,8 4,9 1,3 6,4A 2,8 280 40,6 4,1 1,1 6,9A Fusible nécessaire: 10A 7 WPS2_4-InstructManual.indd 7 2/16/06 7:55:02 PM FRANÇAIS Installation Schéma de câblage Monter la pompe à un endroit sec. 1. Si la pompe est montée verticalement, le moteur doit être tourné vers le haut. 2. Repérer la position des vis et prépercer (voir le gabarit de perçage page 16). 3. Monter la pompe en utilisant des vis inoxydables et en faisant attention à ne pas comprimer les pieds amortisseurs en caoutchouc. 4. Il est recommandé d’utiliser un tuyau flexible renforcé spécial haute pression. Si un tuyau rigide est utilisé, un tuyau flexible d’une longueur de 225 mm/9 pouces minimum devra être installé entre la pompe et le tuyau rigide. Celui-ci va empêcher les bruits et/ou les dégâts causés par les vibrations d’être transmis au tuyau rigide. 5. Utiliser des colliers de serrage en acier inoxydable pour fixer les tuyaux aux raccords rapides et aux autres parties du système. NOTE: Il faut monter le filtre á l’entrée de la pompe pour empêcher les débris d’entrer dans la pompe et entraîner des perturbations de fonctionnement des vannes. Installation électrique 1. La pompe doit être installée conformément à la norme ISO 10133 (Petits bateaux, système électrique, installation à courant continu de très basse tension). Note: Le fusible doit être de type ”antidéflagrant”. 2. Le moteur est équipé d’une sécurité thermique intégrée pour le protéger contre les surchauffes. La protection est automatiquement réarmée lorsque le moteur a refroidi. 3. Si un fil de terre séparé est raccordé à la pompe, il doit être jaune/vert et branché à la base du moteur. Voir le schéma de câblage pour une installation exacte. Le fil négatif doit être noir. 4. Choisir une section de fil en fonction de la longueur totale du fil (voir la page suivante). 5.Utiliser un produit d’étanchéité pour applications marines aux raccords de fil. Note: Avant l’installation des systèmes électriques de commande, vérifier que l’équipement qui va être utilisé a une puissance suffisante pour supporter le courant demandé par le moteur. Une tension faible entraîne une surchauffe du moteur. Maxi. 0,2 m Rouge – + Fusible principal Noir Pompe Vert/jaune Les autres équipements électriques, comme un coupe-cirucit, doivent être installés entre la pompe et le fil positif (+) de la batterie (sur le fil rouge). Section des fils (basée sur une chute de tension de 10%) Section de fil 1,0 mm2 1,5 mm2 2.5 mm2 (18 GA) (16 GA) (14 GA) Longueur de fil* maxi.en m 11.9 17.9 29.8 * La longueur de fil correspond à la distance totale entre la batterie et la pompe et le retour à la batterie. Il est recommandé d’utiliser un relais avec un fil léger partant du fil principal à l’interrupteur pour raccourcir les fils principaux. Maintenance Le système devra être vérifié périodiquement conformément à ci-après: 1. Remplir la cuve avec une solution d’eau de javel ménager et d’eau potable (1 ml de javel par litre d’eau). 2. Ouvrir tous les robinets et faire fonctionner la pompe jusqu’à ce que l’eau qui s’écoule sente la javel. 3. Nettoyer tous les robinets. 4. Vider la solution de la cuve. 5. Remplir la cuve d’eau potable. 6. Ouvrir tous les robinets et faire fonctionner la pompe jusqu’à ce que tout le produit javelisant soit éliminé. 8 WPS2_4-InstructManual.indd 8 2/16/06 7:55:02 PM FRANÇAIS Procédure de mise en service En hiver Après l’installation de la pompe, le système peut être mis en service en suivant la procédure ci-après: • Remplir la cuve d’eau • Ouvrir un robinet • Mettre la pompe en service • Fermer le robinet lorsque l’eau commence à couler. • Ouvrir tous les robinets les uns après les autres pour purger tout l’air contenu dans le système. • La pompe va s’arrêter lorsque tous les robinets sont fermés et que la pression aura atteint le niveau réglé pour le contact de pression. Si l’eau n’est pas vidangée du système lorsque les températures extérieures descendent en dessous de zéro, les conduites et la pompe seront endommagées. Pour éviter ces inconvénients, procéder de la façon suivante: 1. Vider la cuve de stockage d’eau. 2. Ouvrir tous les robinets. 3. Faire fonctionner la pompe jusqu’à ce que toute l’eau restante soit évacuée. 4. Débrancher les conduites d’arrivée et de sortie. 5. Faire tourner brièvement la pompe pour vérifier que toute l’eau a bien été évacuée. 6. Laisser les robinets ouverts et les raccords de pompe débranchés jusqu’à ce que les températures soient remontées au-dessus de zéro. Ne jamais démarrer une pompe gelée. Même si elle a été vidangée, elle peut contenir de très petites quantités d’eau gelée qui vont bloquer le moteur. Auto-amorçage La pompe est auto-amorçante jusqu’à 2 m. Les conduites d’arrivée doivent être étanches à l’air pour assurer l’auto- amorçage. Fonctionnement à sec La pompe ne sera pas endommagée par une courte période de fonctionnement à sec. Elle va cependant réduire inutilement la puissance de votre batterie. ATTENTION: N’utilisez pas la pompe pour d’autres liquides que de l’eau douce et de l’eau de mer. Température Accessoire Model 7923667 Tamis universal Température maxi. du liquide: +50°C Température ambiante maxi.: +60°C Rien n’est plus important pour nous que la satisfaction des clients. Si vous avez des questions ou si le produit que vous avez acheté ne satisfait pas vos attentes, veuillez nous contacter par une des méthodes suivantes: • Contactez le magasin West Marine près de chez vous • Téléphonez au 1-800-BOATING • Visitez-nous à: www.westmarine.com 9 WPS2_4-InstructManual.indd 9 2/16/06 7:55:03 PM FRANÇAIS Plan de recherche de pannes Symptôme Cause Remède La pompe ne fonctionne pas. 1. Sécurité thermique ou fusible déclenchés. 1. Vérifier le fusible. Si la sécurité thermique s’est déclenchée, laisser refroidir le moteur avant de redémarrer. 2. Vérifier la batterie/l’alimentation, l’interrupteur principal et le câblage. 3. Remplacer le contact de pression. 4. Remplacer la pompe. 5. Dégeler la pompe et le système, vérifier les dégâts. La pompe/moteur peuvent être endommagés en démarrant une pompe gelée. 2. Fil ou alimentation incorrectement branchés. 3. Contact de pression défectueux. 4. Moteur défectueux. 5. Pompe/moteur gelés. Pas d’auto-amorçage de la pompe. 1. Cuve d’eau vide. 2. Dépôts sous les vannes. 3. Diaphragme perforé. 4. Fuites sur le côté aspiration de la pompe. 5. Etranglement sur les conduites d’entrée ou de sortie. 1. Remplir la cuve. 2. Avec précautions, rincer la pompe avec de l’eau du robinet à un débit normal de pompe. Note! rincer dans le sens de passage normal de l’eau. 3. Remplacer le kit de pompe complet. 4. Vérifier le serrage des raccords de flexible sur la pompe, le filtre et la cuve. 5. Vérifier les conduites. Cycles de pompe trop rapides en soutirant de l’eau. Etranglement du côté refoulement de la pompe/pression trop élevée. Le flexible de sortie est trop petit, il doit avoir le même diamètre que le raccord de pompe. Cycles de pompe trop rapides sans soutirer de l’eau. Fuites du côté aspiration de la pompe. Vérifier le serrage des raccords de flexible, vérifier le flexible au point de vue dégâts. La pompe ne s’arrête pas sans soutirer de l’eau. 1. Fuites du côté aspiration de la pompe. 2. Fuites du côté refoulement de la pompe. 1. Vérifier le serrage des raccords de flexible, vérifier le flexible au point de vue dégâts. 2. Vérifier le serrage des raccords de flexible, vérifier le flexible au point de vue dégâts. 3. Remplacer le kit de pompe complet. 4. Remplir la cuve. 5. Remplacer le contact de pression. 6. Remplacer la batterie/tension d’alimentation. 3. Diaphragme perforé. 4. Cuve d’eau vide. 5. Contact de pression défectueux. 6. Faible tension à la pompe. Débit/pression insuffisants 1. Fuites du côté aspiration de la pompe. 2. Fuites du côté refoulement de la pompe. 3. Diaphragme perforé. 4. Moteur défectueux. 5. Dépôts sous les vannes. Pompe excessivement bruyante. 1. La pompe est montée directement à une conduite rigide. 2. La tête de pompe se détache du moteur. 3. La pompe est desserrée 4. La pompe est montée trop serrée. 4. Moteur défectueux. 1. Vérifier le serrage des raccords de flexible, vérifier le flexible au point de vue dégâts. 2. Vérifier le serrage des raccords de flexible, vérifier le flexible au point de vue dégâts. 3. Remplacer le kit de pompe complet. 4. Remplacer la pompe. 5. Avec précautions, rincer la pompe avec de l’eau du robinet à un débit normal de la pompe. Note! rincer dans le sens normal de passage d’eau. 1. Monter un flexible conformément aux recommandations d’installation, page 8. 2. Serrer les vis. 3. Serrer les vis. 3. Utiliser un flexible et s’assurer que les pieds amortisseurs en caoutchouc sont bien utilisés. 4. Remplacer la pompe. 10 WPS2_4-InstructManual.indd 10 2/16/06 7:55:03 PM ESPAÑOL Model 7865645 Bomba de presión de agua 2.4 12V bomba de membrana con desplazamiento positivo de cinco cámaras. Aplicaciones típicas Esta bomba es la elección adecuada para la presurización de agua en sistemas cerrados, tales como los de los barcos o los de las autocaravanas. La bomba proporciona la presión necesaria para el suministro de agua a presión. Especificaciones Cuerpo: Alojamiento de válvula: Válvulas: Membrana: Conexión: Características • • • • Funcionamiento silencioso Flujo de caudal uniforme Autocebado El interruptor de presión integrado enciende y apaga la bomba automáticamente al abrir o cerrar el grifo • Funcionamiento en seco sin daños • Bajo consumo • Conexiones de empalme rápido Principios de funcionamiento Cuando la bomba está funcionando, el sistema produce presión hasta alcanzar los 2,8 bares/41psi. Una vez se ha llegado a este valor,el interruptor integrado cierra automáticamente la bomba. La bomba está equipada con válvulas de salida de control positivo, las cuales aseguran el mantenimiento de la presión una vez se ha desconectado la bomba. Cuando se dispone de agua (en los grifos, la ducha, etc.) la presión disminuye. Después de una moderada caída de presión, el presostato integrado pone de nuevo en funcionamiento la bomba. Gracias a su robusta construcción y al cuidado diseño, la bomba proporciona una larga vida de servicio. ¡Advertencia! La configuración y ajuste de los valores de presión de esta bomba se realiza en fábrica. La garantía quedará invalidada en caso de que se manipule el interruptor de presión. Temperatura del líquido: Sujeciones: Altura máxima de aspiración: Presión de arranque: Presión de paro: Ciclo de trabajo: Polipropileno Polyamide EPDM Santopreno ISO228/1-G 3/8" BSP, tubo de 1/2" (13mm) et 1/2" BSP, tubo de 3/4" (19mm) Max.+50 °C Acero inoxidable 2m 1,7 bar/25 Psi 2,8 bar/41 Psi Intermitente 20 minutos máximo Motor: 87 W, 12V DC con protección de sobrecalentamiento incorporada Peso: 2 kg Motor y interruptor con protección de encendido según ISO 8846 (Pequeñas embarcaciones – Artículos eléctricos – Antideflagrante en ambientes de gases inflamables). Datos de presión y caudal Basados en agua a 20 °C y motor a plena tensión. Presión Caudal Amperaje Bar kPa Psi L/mn USGPM 12V 0 0 0 9,4 2,4 2,5A 0,4 40 5,8 8,8 2,3 3,3A 0,8 80 11,6 8,1 2,1 4,0A 1,2 120 17,4 7,3 1,9 4,6A 1,6 160 23,2 6,7 1,8 5,2A 2,0 200 29 5,8 1,5 5,8A 2,4 240 34,8 4,9 1,3 6,4A 2,8 280 40,6 4,1 1,1 6,9A Fusible necesario: 10A 11 WPS2_4-InstructManual.indd 11 2/16/06 7:55:04 PM ESPAÑOL Instalación Situar la bomba en un lugar seco. 1. Si la bomba se instala en sentido vertical,el motor deberá estar hacia arriba. 2. Marcar la posición de los tornillos y perforar los orificios guía (ver la plantilla de perforación en la página 16). 3. Montar la bomba usando tornillos de acero inoxidable, teniendo cuidado de no sobrecomprimir los soportes de goma amortiguadores de vibraciones. 4. Se recomienda el uso de tuberías flexibles reforzadas para alta presión. Si se utiliza tubería rígida, deberá instalarse un tramo (mín. 229mm/9 pulgadas) de tubería flexible entre la bomba y la tubería rígida. Esta medida evitará el ruido y/o los daños causados por las vibraciones a la tubería rígida. 5. Utilizar abrazaderas de acero inoxidable para acoplar la tubería a las conexiones de empalme rápido y a otros tubos del sistema. ¡NOTA! El filtro debe ser instalado en la línea de aspiración inmediatamente antes de la entrada de la bomba, para prevenir la entrada de residuos en la bomba y las interferencias en el funcionamiento adecuado de las válvulas. Instalación eléctrica 1. La bomba deberá instalarse según las nomas ISO 10133 (Pequeñas embarcaciones – Artículos eléctricos – Bajo voltaje de CC para funcionamiento continuo). Nota: El fusible debe ser antideflagrante. 2. El motor tiene incorporado un dispositivo para evitar el sobrecalentamiento. El funcionamiento se restablece automáticamente cuando el motor se enfría. 3. Si la bomba se instala con toma de tierra, se utilizará un cable amarillo/ verde y se conectará a la base del motor. 4. Para la instalación correcta del mismo, ver el esquema eléctrico en la página siguiente. El cable negativo deberá ser decolor negro. Instalar la sección de cableque corresponda según la longitud totaldel cable . 5. Todas las conexiones con cable eléctrico deben sellarse con un compuesto para aplicaciones marinas. ¡Nota! En las instalaciones con interruptor automático de protección deberá comprobarse que la unidad a utilizar tiene lacapacidad nominal necesaria parasoportar el amperaje del motor. La baja tensión produce recalentamiento del motor. Esquema eléctrico Maxi. 0,2 m Rojo – + Fusible principal Negro Bomba Verde/amarillo El resto de los dispositivos eléctricos, es decir, el interruptor, el conmutador de circuito, deberán instalarse entre la bomba y el polo positivo de la batería (en el cable rojo). Tabla de cables (basada en una caída de voltaje del 10%) Long. máx*de Sección cable cable en metros 1,0 mm2 (18 GA) 11.9 1,5 mm2 (16 GA) 17.9 2.5 mm2 (14 GA) 29.8 * La longitud de cable es la distancia total desde la batería hasta la bomba y regreso a la batería. Se recomienda usar un relé con un hilo eléctrico que vaya desde el cable principal al interruptor para acortar los conductores principales. Mantenimiento El sistema debe sanearse periódica-mente, según las instrucciones siguientes: 1. Llenar el depósito con una solución de lejía doméstica y agua potable (1 ml de lejía por litro de agua). 2. Abrir todos los grifos y dejar correr el agua hasta que el flujo de agua huela a lejía. 3. Cerrar todas los grifos. 4. Vaciar el tanque con la solución de agua y lejía. 5. Rellenar el depósito con agua potable. 6. Abrir todas los grifos y dejar correr el agua hasta que se haya purgado la lejía. 12 WPS2_4-InstructManual.indd 12 2/16/06 7:55:04 PM ESPAÑOL Instrucciones de arranque Una vez realizada la instalación de la bomba, seguir las siguientes instrucciones para el arranque del sistema: • Llenar el depósito de agua • Abrir un grifo • Encender la bomba • Cerrar el grifo una vez el agua empieza a fluir • Abrir los grifos adicionales hasta que se haya purgado todo el aire del sistema • La bomba se apagará una vez cerrados todos los grifos y se haya alcanzado una presión equivalente al valor de cierre del interruptor de presión Autocebado La bomba se ceba automáticamente hasta un máximo de 2m de altura. Las líneas de alimentación deben ser herméticas para garantizar el autocebado. Funcionamiento en seco La bomba no se verá dañada si funciona en seco durante un corto periodo de tiempo. Aunque al funcionar en seco se reducirá innecesariamente la carga de la batería. PRECAUCIÓN: No utilizar la bomba con otros líquidos que no sea agua dulce o agua de mar. Protección contra los agentes invernales Si no se vacía el agua del sistema durante épocas con temperaturas bajo cero, es probable que el sistema de tuberías y la bomba sufran daños. Para evitar daños de este tipo, seguir las siguientes instrucciones: 1. Drenar el depósito de almacenamiento de agua. 2. Abrir todos los grifos. 3. Hacer funcionar la bomba hasta que se haya expulsado toda el agua. 4. Desconectar los tubos de entrada y los tubos de salida. 5. Hacer funcionar la bomba para confirmar que se ha expulsado la totalidad del agua. 6. Los grifos deberán permanecer abiertos y las conexiones de la bomba desacopladas hasta que la temperatura sea superior al punto de congelación del agua. No arrancar nunca una bomba que esté congelada. A pesar deque haya sido drenada, podría contener pequeñas cantidades de hielo que bloquearían el motor. Accesorio Model 7923667 Tamiz universal Temperatura Temperatura máx.de líquidos:+ 50 °C Temperatura máx.ambiente: +60 °C Para nosotros no hay nada más importante que la satisfacción del cliente. Si tiene alguna pregunta o si su compra no está a la altura de sus expectativas, siga una de las siguientes opciones: • Póngase en contacto con su tienda local de West Marine • Llame al 1-800-BOATING • Póngase en contacto con nosotros en www.westmarine.com 13 WPS2_4-InstructManual.indd 13 2/16/06 7:55:05 PM ESPAÑOL Tabla de localización de averías Síntoma La bomba no funciona. Causa 1. Protector térmico desconectado o fusible fundido. 2. Conexión defectuosa de cable o de fuente de suministro de energía. 3. Avería en el interruptor de presión. 4. Avería en el motor. 5. Bomba/motor congelados. La bomba no realiza la operacíon de cebado. 1. Depósito de agua vacío. 2. Residuos debajo de las válvulas. 3. Membrana perforada. 4. Pérdida en el lado de entrada de la bomba. 5. Tuberías de entrada o salida con restricciones. Medida 1. Controlar fusible. Si el motor está sobrecalentado, dejar que se enfríe antes de ponerlo en marcha. 2. Controlar batería/fuente de sumistro de energía, interruptor principal y cables. 3. Cambiar interruptor de presión. 4. Cambiar bomba. 5. Descongelar el motor y el sistema y controlar los posibles daños. La bomba/el motor pueden quedar dañados al arrancar una bomba congelada. 1. Llenar el depósito. 2. Limpiar, cuidadosamente, la bomba con agua del grifo al flujo de bombeo nominal. ¡Nota! Limpiar en la direccíon de bombeo nominal. 3. Cambiar el juego de bomba. 4. Controlar que la estanqueidad de las conexiones a la bomba, el filtro y el depósito. 5. Controlar las tuberías. La bomba se detiene y se ponen en marcha repetidas veces cuando se necesita agua. Restricciones en el lado de salida de la bomba; presión demasiado alta. Tubo de salida demasiado estrecho; debe tener el mismo diámetro que la conexión. La bomba se detiene y se pone en marcha repetidas veces cuando se necesita agua. Pérdida en el lado de salida de la bomba. Controlar la estanqueidad de las conexiones de los tubos; controlar posibles daños en los tubos. La bomba no se detiene cuando no se necesita agua. 1. Pérdida en el lado de entrada de la bomba. 1. Controlar la estanqueidad de las conexiones de los tubos; controlar posibles daños en los tubos. 2. Controlar la estanqueidad de las conexiones de los tubos; controlar posibles daños en los tubos. 3. Cambiar el juego de bomba. 4. Llenar el depósito. 5. Cambiar el interruptor de presión. 2. Pérdida en el lado de salida de la bomba. 3. Diagrama perforado. 4. Depósito de agua vacío. 5. El interruptor de presión funciona defectuosamente. 6. Tensión baja a la bomba. Flujo bajo/baja presión. 1. Pérdida en el lado de entrada de la bomba. 2. Pérdida en el lado de salida de la bomba. 3. Diagrama perforado. 4. Motor averiado. 5. Residuos debajo de las válvulas. La bomba hace demasiado. 6. Cambiar la batería/suministro de energía. 1. Controlar la estanqueidad de las conexiones de los tubos; controlar posibles daños en los tubos. 2. Controlar la estanqueidad de las conexiones de los tubos; controlar posibles daños en los tubos. 3. Cambiar el juego de bomba. 4. Cambiar la bomba. 5. Limpiar, cuidadosamente, la bomba con agua del grifo al flujo de bombeo nominal. ¡Nota! Limpiar en la dirección de bombeo nominal. 1 La bomba está acoplada/soldada directamente a la tubificación rígida. 1. Instalar tubificación flexible según las recomendaciones de montaje, ver página 12. 2. El cabezal de la bomba está suelto en 2. Apretar los tornillos. el motor. 3. Los tornillos de la bomba están flojos. 3. Apretar los tornillos. 4. Usar tubificación flexible y comprobar 4. El montaje de la bomba es demasiado rígido. que se usan los pies amortiguadores de goma. 5. Motor defectuoso. 5. Cambiar la bomba. 14 WPS2_4-InstructManual.indd 14 2/16/06 7:55:05 PM Dimensions mm/inches Dimensions mm/pouces Dimensiones mm/pulgadas 65 / 2.559 57 / 2.244 202 / 7.593 197 / 7.56 74 / 2.913 111 / 4.37 81 / 3.189 15 WPS2_4-InstructManual.indd 15 2/16/06 7:55:06 PM 3.189 inch 81 mm Hole layout 1:1 Schéma de perçage 1:1 Croquis agujeros 1:1 57 mm 2.244 inch 500 Westridge Dr. Watsonville, CA 95076 Made in USA www.westmarine.com 16 WPS2_4-InstructManual.indd 16 2/16/06 7:55:07 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

West Marine 7865645 El manual del propietario

Tipo
El manual del propietario