Honeywell FOCUSPROTM TH5000 Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

FocusPRO
TM
TH5000 Series
Non-Programmable Digital Thermostat
® U.S. Registered Trademark. Patents pending.
Copyright © 2006 Honeywell International Inc.
All rights reserved.
Installation
Guide
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502
69-1922ES
This manual covers the following models
TH5110D: For 1 Heat/1 Cool systems
TH5220D: For up to 2 Heat/2 Cool systems
TH5320U: For up to 3 Heat/2 Cool systems
(Remove battery holder to find model number)
System Types
Gas, oil, or electric heat with air
conditioning
Warm air, hot water, high-
efficiency furnaces, heat pumps,
steam, gravity
Heat only — two-wire systems,
three-wire zone valves (Series
20), and normally open zone
valves
Heat only with fan
Cool only
750 mV heating systems
Installation Guide
Wallplate installation
1. Separate wallplate from thermostat.
2. Mount wallplate as shown below.
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wall anchors
Wallplate
Wire hole
Mounting screws
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not
place the old control in the trash. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
!
Pull here to remove wallplate
from new thermostat.
Remove battery holder.
!
It's easier to grasp the wallplate
and remove it after completely
removing the battery holder.
FocusPRO
TM
TH5110 / TH5220 / TH5320
Power options
Keep wires in this
shaded area
Connect C for primary AC power
(optional if batteries are installed).
Insert batteries for primary
or backup power.
Remove factory-
installed jumper
only for two-
transformer
systems.
Conventional Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
W Heat relay (stage 1)
W2 Heat relay (stage 2)
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2)
G Fan relay
C 24VAC common. For 2 transformer
systems, use common wire from
cooling transformer.
Heat Pump Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
O/B Changeover valve
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2) -
TH5320U only
G Fan relay
Aux Auxiliary heat relay*
E Emergency heat relay*
L Sends output when set to Em. Heat
C 24VAC common
*Aux and E terminals combined on TH5320U only.
Wiring
Terminal designations
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
TH5110D
Rc
Y
W
G
R
C
TH5110D
Rc
Y
O/B
G
R
C
TH5220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH5220D
TH5320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH5320U
TH5110D
Rc
Y
W
G
R
C
TH5110D
Rc
Y
O/B
G
R
C
TH5220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH5220D
TH5320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH5320U
Installation Guide
Wiring
Wiring guide — conventional systems
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire.
Shielded cable is not required.
[1] Power supply. Provide disconnect means
and overload protection as required.
[2] Remove jumper for 2-transformer systems.
[3] Optional 24VAC common connection.
[4] Common connection must come from
cooling transformer.
[5] In Installer Setup, set system type to
Heat Only.
[6] In Installer Setup, set system type to
2Heat/2Cool Conventional.
[7] In Installer Setup, set changeover valve to
O or B.
[8] In Installer Setup, set system type to
2Heat/1Cool Heat Pump.
[9] In Installer Setup, set system type to
2Heat/2Cool Heat Pump.
[10] In Installer Setup, set system type to
3Heat/2Cool Heat Pump.
[11] L terminal sends a continuous output when
thermostat is set to Em. Heat. Connect
to Honeywell zoning panels to switch the
panel to Emergency Heat.
[12] Install field jumper between Aux and E if
there is no emergency heat relay.
1H/1C System
(1 transformer)
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
W Heat relay
G Fan relay
Heat-only System
Rc Power [1]
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
Heat-only System
(Series 20) [5]
Rc [R+Rc joined by jumper]
R Series 20 valve terminal “R” [1]
Y Series 20 valve terminal “W”
C 24VAC common [3]
W Series 20 valve terminal “B”
Heat-only System
(normally open zone valve) [5]
Rc [R+Rc joined by jumper]
R Power [1]
Y Normally open zone valve
C 24VAC common [3]
1H/1C System
(2 transformers)
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor
C 24VAC common [3, 4]
W Heat relay
G Fan relay
Heat-only System
with Fan
Rc Power [1]
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
G Fan relay
Cool-only System
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
G Fan relay
2H/2C System
(1 transformer) [6]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
2H/2C System
(2 transformers) [6]
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor (stage 1)
C 24VAC common [3, 4]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
See [notes] below
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
FocusPRO
TM
TH5110 / TH5220 / TH5320
Wiring
Wiring guide — heat pump systems
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
Thermostat mounting
Align the 4 tabs on the wallplate with
slots on the back of the thermostat,
then push gently until the thermostat
snaps in place.
Push excess wire back into
the wall opening.
Plug wall opening with
non-flammable insulation.
1H/1C Heat
Pump System
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
2H/1C Heat
Pump System
(TH5220D only) [8]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux Auxiliary heat relay [12]
E Emergency heat relay [12]
L Sends output when set to Em. Heat [11]
2H/1C Heat
Pump System
(TH5320U only) [8]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux/E Auxiliary/Emergency heat relay
L Sends output when set to Em. Heat [11]
2H/2C Heat
Pump System
(TH5320U only) [9]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Y2 Compressor contactor (stage 2)
L Sends output when set to Em. Heat [11]
3H/2C Heat
Pump System
(TH5320U only) [10]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux/E Auxiliary/Emergency heat relay
Y2 Compressor contactor (stage 2)
L Sends output when set to Em. Heat [11]
See [notes] on page 4.
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
Installation Guide
To begin, press and hold the s and FAN
buttons until the display changes.
Function
number
Setting
Press s or t to change settings.
Press NEXT to advance to the next function.
Press DONE to exit and save settings.
1
0
Done Next
Installer setup
Follow the procedure below to configure the thermostat to match the installed
heating/cooling system, and customize feature operation as desired.
Continued on next page
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
1 System type 0 1 heat/1 cool conventional
1 1 heat/1 cool heat pump (no aux. heat)
2 Heat only — 2-wire systems, 3-wire zone valves (Series 20), and
normally open zone valves
3 Heat only with fan
4 Cool only
5 2 heat/1 cool heat pump (with aux. heat)
6 2 heat/2 cool conventional
7 2 heat/1 cool conventional
8 1 heat/2 cool conventional
9 2 heat/2 cool heat pump (no aux. heat) - TH5320U only
10 3 heat/2 cool heat pump (with aux. heat) - TH5320U only
2 Changeover valve
(O/B terminal)
0 Changeover valve (O/B terminal energized in cooling)
1 Changeover valve (O/B terminal energized in heating)
3 Fan control
(heating)
0 Gas or oil furnace equipment controls fan in heating
1 Electric furnace — thermostat controls fan in heating
5 Stage 1 heat cycle
rate (CPH: cycles/hour)*
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
6 Stage 2 heat cycle
rate/Auxiliary heat
cycle rate (CPH)*
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
7 Auxiliary heat cycle
rate (CPH)*
Only TH5320U
for 3H/2C Heat Pumps
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
8 Emergency heat cycle
rate (CPH)*
9 For electric emergency heat
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
5 For gas or oil furnaces of less than 90% efficiency
FocusPRO
TM
TH5110 / TH5220 / TH5320
System test System status
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
Press s / t to turn system on/off.
Press NEXT to advance to next test.
Press DONE to terminate system test.
Test number
System status
10
0
To begin, press and hold the s and t
buttons until the display changes
Installer setup
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted.
CAUTION: Compressor protection is bypassed during testing. To prevent equipment
damage, avoid cycling the compressor quickly
!
10 Heating system 0 Heat and fan turn off.
1 Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1,
5, 9 or 10 OR Setup Function 3 is set to 1 **See page 6
2 Stage 2 heat turns on
3 Stage 3 heat turns on - TH5320U only
20 Emergency heating
system
0 Heat and fan turn off
1 Heat and fan turn on
2 Stage 2 heat turns on (auxiliary heat) - TH5220D only
30 Cooling system 0 Compressor and fan turn off
1 Compressor and fan turn on
2 Stage 2 compressor turns on
40 Fan system 0 Fan turns off
1 Fan turns on
9 Stage 1 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
10 Stage 2 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
12 Manual/Auto
changeover
0 Manual changeover (Heat/Cool/Off)
1 Auto changeover (Heat/Cool/Auto/Off)
2 Auto changeover only (Auto)
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor
protection
5 Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
26 Auxiliary heat control 0 Comfort **See page 8
1 Economy
27 Heat temperature
range stops
90 Max. heat temperature setting is 90 °F (32 °C)
[Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)]
28 Cool temperature
range stops
50 Min. cool temperature setting is 50 °F (10 °C)°F (10 °C)F (10 °C)°C)C)
[Other options: 51 °F to 99 °F (10.5 °C to 37 °C)]
Installer system test
Installation Guide
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://yourhome.honeywell.com
Automation and Control Solutions
® U.S. Registered Trademark.
© 2006 Honeywell International Inc.
69-1922ES M.S. 03-06
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
Special function
Auxiliary heat control (Setup Function 26):
Comfort Setting: The thermostat will prioritize comfort over economy depending on heat
pump performance, load conditions and whether the thermostat is calling for the heat
pump. Raising the temperature just a few degrees will often activate the auxiliary heat.
Economy Setting: The thermostat will attempt to reach the temperature setting
without activating the auxiliary heat. The thermostat will wait to activate the auxiliary
heat depending on heat pump performance, load conditions and how many degrees the
temperature setting is changed.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Part Description Part Number Use With
Battery holder 50000951-001 TH5110D
Battery holder 50007072-001 TH5320U/TH5220D
Cover plate assembly* 50001137-001 TH5110D
Cover plate assembly* 50002883-001 TH5320U/TH5220D/TH5110D
12 pack of small cover plates* 50007297-001 TH5110D
12 pack of medium cover plates* 50007298-001 TH5320U/TH5220D/TH5110D
*Use to cover marks left by old thermostats.
Specifications
Temperature Ranges
Heat: 40° to 90°F (4.5° to 32°C)
Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)
Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions
TH5320U/TH5220D
3-9/16" H x 5-13/16" W x 1-1/2" D
91 mm H x 147 mm W x 38 mm D
TH5110D
3-7/16" H x 4-1/2" W x 1-5/16" D
86 mm H x 114 mm W x 33 mm D
Electrical Ratings
Terminal Voltage (50/60Hz) Running Current
W Heating 20-30 Vac 0.02-1.0 A
(Powerpile) 750 mV DC 100 mA DC
W2 (Aux) Heating 20-30 Vac 0.02-0.5 A
Y Cooling 20-30 Vac 0.02-1.0 A
Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
O/B Changeover 20-30 Vac 0.02-0.5 A
E Emergency heat 20-30 Vac 0.02-1.0 A
L Output 20-30 Vac 0.02-0.5 A
Serie FocusPRO
TM
TH5000
Termostato digital no programable
® Marca registrada de los EE. UU. Patentes en trámite.
© 2006, Honeywell International Inc.
Todos los derechos reservados.
Guía de
instalación
Debe ser instalado por un técnico
capacitado y experimentado
Lea estas instrucciones atentamente. Si no sigue estas instrucciones,
puede dañar el producto u ocasionar un riesgo.
¿Necesita asistencia?
Para obtener asistencia relacionada con este producto,
visite http://yourhome.honeywell.com o comuníquese con el número gratuito
del Centro de atención al cliente de Honeywell, llamando al 1-800-468-1502
69-1922ES
Este manual incluye los siguientes modelos:
TH5110D: Para sistemas de 1 calentador y 1 refrigerador
TH5220D: Para sistemas de 2 calentadores y 2 refrigeradores
TH5320U: Para sistemas de 3 calentadores y 2 refrigeradores
(Quite el soporte de la batería para ver el número de modelo)
Tipos de sistema
Sistema de calefacción a gas,
a aceite o eléctrico con aire
acondicionado
Calefaccn de aire, agua caliente,
sistemas de calefacción de alta
efectividad, bombas de calor,
vapor, gravedad
lo calor: sistemas de dos cables,
válvulas de separación de tres
cables (serie 20) y válvulas de
separación normalmente abiertas
Sólo calor con ventilador
Sólo frío
Sistemas de calefacción de 750 mV
Guía de instalación
2
Instalación de la placa para pared
1. Quite la placa para pared del termostato.
2. Monte la placa para pared como muestra
la ilustración de abajo.
En tablarroca, realice agujeros de 3/16". En yeso, realice agujeros de 7/3".
Anclas de expansión
Placa para pared
Agujero para el cable
Tornillos de montaje
PRECAUCIÓN: RIESGO ELÉCTRICO
Puede ocasionar descargas eléctricas o dañar el equipo. Desconéctelo de la fuente
de energía antes de comenzar la instalación.
AVISO SOBRE EL MERCURIO
En caso de que este producto reemplace a un control que contenga mercurio
en tubo sellado, evite arrojar el viejo control a la basura. Póngase en contacto con
la autoridad local para el manejo de desechos a fin de obtener instrucciones sobre
el reciclado y la correcta eliminación de este tipo de desechos.
!
Hale de aquí para quitar la placa
para pared del nuevo termostato.
Extraiga el soporte de la batería.
!
Es más fácil quitar la placa
para pared una vez que
se extrae completamente
el soporte de la batería.
FocusPRO
TM
TH5110 / TH5220 / TH5320
3
Opciones de fuentes de energía
Mantenga los cables
en esta área
sombreada
Conecte C para suministrar corriente CA
(opcional si las baterías están instaladas).
Coloque las baterías para suministro
de energía principal o de respaldo.
Quite el puente
instalado en la
fábrica sólo en los
sistemas con dos
transformadores.
Terminales convencionales:
Rc 24 V CA desde el transformador
del sistema de refrigeración
R 24 V CA desde el transformador
de la calefacción
W Relé de calor (etapa 1)
W2 Relé de calor (etapa 2)
Y Interruptor automático del compresor
(etapa 1)
Y2 Interruptor automático del compresor
(etapa 2)
G Relé del ventilador
C 24 V CA. Para los sistemas de
2 transformadores, utilice cables
comunes desde el transformador
de la refrigeración.
Terminales de la bomba de calor:
Rc 24 V CA desde el transformador
de la refrigeración
R 24 V CA desde el transformador
de la calefacción
O/B Válvula inversora
Y Interruptor automático del compresor
(etapa 1)
Y2 Interruptor automático del compresor
(etapa 2) (únicamente TH5320U)
G Relé del ventilador
Aux Relé auxiliar de calor*
E Relé de emergencia de calor*
L Cuando se fija en Em. Heat, envía
un flujo de aire caliente
C 24 V CA
* Terminales Aux y E combinados únicamente en el
modelo TH5320U.
Cableado
Designación de terminales
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos
TH5320U y TH5220D o según se indique.
TH5110D
Rc
Y
W
G
R
C
TH5110D
Rc
Y
O/B
G
R
C
TH5220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH5220D
TH5320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH5320U
TH5110D
Rc
Y
W
G
R
C
TH5110D
Rc
Y
O/B
G
R
C
TH5220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH5220D
TH5320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH5320U
Guía de instalación
4
Cableado
Guía de cableado: sistemas convencionales
Las áreas sombreadas que aparecen abajo sólo se utilizan en el caso de los modelos
TH5320U y TH5220D o según se indique.
NOTAS
Especificaciones del cable:
Use cable para termostato de calibre
18 a 22. No se requiere cable blindado.
[1] Fuente de alimentación. Proporciona
el medio de desconexión y la protección
contra sobrecargas requeridos.
[2] Para sistemas de 2 transformadores quite
el puente.
[3] Conexión común de 24 V CA opcional.
[4] La conexión común debe provenir del
transformador de refrigeración.
[5] Durante la configuracn de instalación,
coloque el tipo de sistema en “Heat Only”.
[6] Durante la configuración de instalación,
coloque el tipo de sistema en Convencional
de 2 calentadores y 2 refrigeradores.
[7] Durante la configuración de instalación, coloque
la válvula inversora en la posición O o B.
[8] Durante la configuración de instalación,
coloque el tipo de sistema en Bomba de
calor de 2 calentadores y 1 refrigerador.
[9] Durante la configuración de instalación,
coloque el tipo de sistema en Bomba de
calor de 2 calentadores y 2 refrigeradores.
[10] Durante la configuración de instalación,
coloque el tipo de sistema en Bomba de
calor de 3 calentadores y 2 refrigeradores.
[11] El terminal L envía un flujo continuo de aire
caliente cuando el termostato está en la
posición Em. Heat. Conéctelo a los paneles
de separación de Honeywell para cambiar
a Em. Heat.
[12] Coloque el puente de campo entre Aux
y E si no existe un re de emergencia de calor.
Sistema de 1 calentador
y 1 refrigerador (1 transformador)
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
W Relé de calor
G Relé del ventilador
Sistema de calefacción
únicamente
Rc Electricidad [1]
R [R+Rc unidos por un puente]
C 24 V CA [3]
W Relé de calor
Sistema de calefacción
únicamente (Serie 20) [5]
Rc [R+Rc unidos por un puente]
R Terminal “R” de la válvula de la serie 20 [1]
Y Terminal “W” de la válvula de la serie 20
C 24 V CA [3]
W Terminal “B” de la válvula de la serie 20
Sistema de calefacción
únicamente (válvula de
separación normalmente abierta) [5]
Rc [R+Rc unidos por un puente]
R Electricidad [1]
Y Válvula de separación normalmente abierta
C 24 V CA [3]
Sistema de 1 calentador
y 1 refrigerador (2 transformadores)
Rc Electricidad (transformador de refrigeración) [1, 2]
R Electricidad (transformador de calefacción) [1, 2]
Y Interruptor automático del compresor
C 24 V CA [3, 4]
W Relé de calor
G Relé del ventilador
Sistema de calefacción
únicamente con ventilador
Rc Electricidad [1]
R [R+Rc unidos por un puente]
C 24 V CA [3]
W Relé de calor
G Relé del ventilador
Sistema únicamente
de refrigeración
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
G Relé del ventilador
Sistema de 2 calentadores
y dos refrigeradores
(1 transformador) [6]
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor (etapa 1)
C 24 V CA [3]
W Relé de calor (etapa 1)
G Relé del ventilador
W2 Relé de calor (etapa 2)
Y2 Interruptor automático del compresor (etapa 2)
Sistema de 2 calentadores
y dos refrigeradores
(2 transformadores) [6]
Rc Electricidad (transformador de refrigeración) [1, 2]
R Electricidad (transformador de calefacción) [1, 2]
Y Interruptor automático del compresor (etapa 1)
C 24 V CA [3, 4]
W Relé de calor (etapa 1)
G Relé del ventilador
W2 Relé de calor (etapa 2)
Y2 Interruptor automático del compresor (etapa 2)
Vea [notas] abajo
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
RcW RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
Rc
YG
R
C
RcYWG
R
C
RcWG
R
C
RcYWG
R
C
Rc
YW RC
Rc
Y RC
FocusPRO
TM
TH5110 / TH5220 / TH5320
5
Cableado
Guía de cableado: sistemas de bomba de calor
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos
TH5320U y TH5220D o según se indique.
Montaje del termostato
Alinee las 4 lengüetas de la placa
de pared con las ranuras de la parte
posterior del termostato y presione
levemente hasta que el termostato
encaje en su lugar.
Coloque el excedente de cable
en el interior de la abertura
de la pared.
Tape la abertura de la pared con
un aislamiento no inflamable.
Sistema de bomba de
calor de 1 calentador
y 1 refrigerador
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Sistema de bomba de
calor de 2 calentadores
y 1 refrigerador
(únicamente TH5220D) [8]
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Aux Relé auxiliar de calor [12]
E Relé de emergencia de calor [12]
L Cuando se fija en Em. Heat, envía un flujo de aire
caliente [11]
Sistema de bomba de
calor de 2 calentadores
y 1 refrigerador
(únicamente TH5320U) [8]
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Aux/E Relé de calor auxiliar/de emergencia
L Cuando se fija en Em. Heat, envía un flujo
de aire caliente [11]
Sistema de bomba de
calor de 2 calentadores
y 2 refrigeradores
(únicamente TH5320U) [9]
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor (etapa 1)
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Y2 Interruptor automático del compresor (etapa 2)
L Cuando se fija en Em. Heat, envía un flujo de aire
caliente [11]
Sistema de bomba de
calor de 3 calentadores
y 2 refrigeradores
(únicamente TH5320U) [10]
Rc Electricidad [1]
R [R+Rc unidos por un puente]
Y Interruptor automático del compresor (etapa 1)
C 24 V CA [3]
O/B Válvula inversora [7]
G Relé del ventilador
Aux/E Relé de calor auxiliar/de emergencia
Y2 Interruptor automático del compresor (etapa 2)
L Cuando se fija en Em. Heat, envía un flujo
de aire caliente [11]
Vea las [notas] en la página 4.
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
RcYG RC
RcYGAuxEL RC
RcYGAux
E
L RC
RcYGY2
RcYGAux
E
L RC
Y2
L RC
Guía de instalación
6
Para comenzar, pulse y mantenga
presionados los botones s y “FAN”
hasta que cambie la pantalla.
Número de función
Configuración
Presione s o t para cambiar la configuración.
Presione NEXT para avanzar a la siguiente función.
Presione DONE para salir y guardar la configuración.
1
0
DONE NEXT
Configuración de instalación
Siga el procedimiento que aparece a continuación para configurar el termostato
a fin de que se corresponda con el sistema de calefacción y refrigeración
instalado, y seleccione las funciones según lo desee.
Continúa en la página siguiente
Funciones de la Configuraciones y opciones (las que vienen
configuración desde la fábrica aparecen en negrita)
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos
TH5320U y TH5220D o según se indique.
* [Otras opciones de velocidad de ciclo: 2, 4, 6, 7, 8, 10, 11 ó 12 CPH]
1 Tipo de sistema 0 1 calentador y 1 refrigerador convencional
1 1 bomba de calor con calentador y 1 refrigerador (sin calor aux.)
2 Sólo calor — sistemas de dos cables, válvulas de separación de tres cables
(serie 20) y válvulas de separación normalmente abiertas
3 Sólo calor con ventilador
4 Sólo frío
5 Bomba de calor con 2 calentadores y 1 refrigerador (con calor aux.)
6 2 calentadores y 2 refrigeradores convencionales
7 2 calentadores y 1 refrigerador convencional
8 1 calentador y 2 refrigeradores convencionales
9 Bomba de calor con 2 calentadores y 2 refrigeradores (sin calor aux.)
únicamente en TH5320U
10 Bomba de calor con 3 calentadores y 2 refrigeradores (con calor aux.)
únicamente TH5320U
2 Válvula inversora
(terminal O/B)
0 Válvula inversora (terminal O/B con energía durante la refrigeración)
1 Válvula de inversora (terminal O/B con energía durante la calefacción)
3 Control del ventilador
(calefacción)
0 Sistemas de calefacción a gas o a aceite (el equipo controla
al ventilador para calefacción)
1 Sistema de calefacción eléctrico (el termostato controla el ventilador
para calefacción)
5 Velocidad del ciclo térmico
de la primera etapa
(CPH: ciclos por hora)*
5 Para sistemas de calefacción a gas o a aceite de menos de un
90% de efectividad
1 Para sistemas de vapor o de gravedad
3 Para sistemas de agua caliente y sistemas de más de un 90% de efectividad
9 Para sistemas eléctricos
6 Velocidad de ciclo térmico/
ciclo de calor auxiliar de la
etapa 2 (CPH)*
5 Para sistemas de calefacción a gas o a aceite de menos de un
90% de efectividad
1 Para sistemas de vapor o de gravedad
3 Para sistemas de agua caliente y sistemas de más de un 90% de efectividad
9 Para sistemas eléctricos
7 Velocidad de ciclo de calor
auxiliar (CPH)*
Únicamente TH5320U
para sistemas de bombas
de calor de 3 calentadores
y 2 refrigeradores
5 Para sistemas de calefacción a gas o a aceite de menos de un
90% de efectividad
1 Para sistemas de vapor o de gravedad
3 Para sistemas de agua caliente y sistemas de más de un 90% de efectividad
9 Para sistemas eléctricos
8 Velocidad de ciclo de calor
de emergencia (CPH)*
9 Para calor de emergencia eléctrica
1 Para sistemas de vapor o de gravedad
3 Para sistemas de agua caliente y sistemas de más de un 90% de efectividad
5 Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad
FocusPRO
TM
TH5110 / TH5220 / TH5320
7
Prueba del sistema Estado del sistema
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos
TH5320U y TH5220D o según se indique.
Presione s / t para encender o apagar
el sistema.
Presione “NEXT” para avanzar hacia
la próxima prueba.
Presione “DONE” para finalizar la prueba
del sistema.
Número de prueba
Estado del sistema
10
0
Para comenzar, pulse y mantenga
presionados los botones s y t
hasta que cambie la pantalla
Configuración de instalación
Funciones de la Configuraciones y opciones (las que vienen
configuración desde la fábrica aparecen en negrita)
Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos
TH5320U y TH5220D o según se indique.
PRECAUCIÓN: Durante la prueba, se desactiva la protección del compresor. Para evitar
daños en el equipo, no permita que el compresor funcione a velocidades altas.
!
10 Sistema de calefacción 0 El calentador y el ventilador se apagan
1 El calentador de la etapa 1 se enciende. El ventilador se enciende si la función
1 de la configuración se coloca en 1, 5, 9 o 10, o si la función 3 de la configuración
se coloca en 1. **Vea la página 6
2 El calentador de la etapa 2 se enciende.
3 El calentador de la etapa 3 se enciende únicamente en TH5320U
20 Sistema de calefacción
de emergencia
0 El calentador y el ventilador se apagan
1 El calentador y el ventilador se apagan
2 El calentador de la etapa 2 se enciende (calor auxiliar) únicamente en TH5220D
30 Sistema de enfriamiento 0 El compresor y el ventilador se apagan
1 El compresor y el ventilador se encienden
2 El compresor de la etapa 2 se enciende
40 Sistema del ventilador 0 El ventilador se apaga
1 El ventilador se enciende
9 Rango de ciclos del com-
presor de la etapa 1 (CPH)
3 Recomendado para la mayoría de los compresores
[Otras opciones de rango de ciclos: 1, 2, 4, 5 ó 6 CPH]
10 Rango de ciclos del
compresor de la
etapa 2 (CPH)
3 Recomendado para la mayoría de los compresores
[Otras opciones de rango de ciclos: 1, 2, 4, 5 ó 6 CPH]
12 Conversión manual/
automática
0 Conversión manual (calor/frío/apagado)
1 Conversión automática (calor/frío/automático/apagado)
2 Sólo conversión automática (Auto)
14 Visor de temperatura 0 Fahrenheit
1 Celsius
15 Protección
del compresor
5 Tiempo de apagado de 5 minutos para el compresor
[Otras opciones: tiempo de apagado de 0, 1, 2, 3 ó 4 minutos]
26 Control de calor auxiliar 0 Comfort **Vea la página 8
1 Economía
27 Limitador de rango
de temperatura del
sistema de calefacción
90 La configuración máxima de temperatura es de 90 °F (32 °C)
[Otras opciones: 40 °F a 89 °F (4,5 °C a 31,5 °C)]
28 Limitador de rango
de temperatura del
sistema de enfriamiento
50 La configuración mínima de enfriamiento es de 50 °F (10 °C)
[Otras opciones: 51 °F a 99 °F (10,5 °C a 37 °C)]
Prueba del sistema
Guía de instalación
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://yourhome.honeywell.com
Soluciones para automatización y control
® Marca registrada de los EE. UU.
© 2006, Honeywell Internacional Inc.
69-1922ES M.S. 03-06
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V4Z9
Impreso en los EE. UU., en papel
reciclado que contiene por lo menos
un 10% de fibras de papel reciclable.
Funciones especiales
Control de calor auxiliar (configuración 26):
Configuración comfort: El termostato prioriza el confort sobre la econoa dependiendo
del funcionamiento de la bomba de calor, de las condiciones de carga y de si el termostato
requiere el uso de la bomba de calor. El incremento de la temperatura en unos pocos
grados a menudo activará el calentador auxiliar.
Configuración económica: El termostato intentará alcanzar la temperatura de configuración
sin activar el calentador auxiliar. El termostato esperará hasta activar el calentador auxiliar
dependiendo del funcionamiento de la bomba de calor, de las condiciones de carga
y de la cantidad de grados que varíe la configuración.
Accesorios y piezas de repuesto
Póngase en contacto con su distribuidor para solicitar piezas de repuesto.
Descripción de las piezas mero de pieza Se usa con
Soporte de la batería 50000951-001 TH5110D
Soporte de la batería 50007072-001 TH5320U/TH5220D
Ensamblado de la placa de cubierta* 50001137-001 TH5110D
Ensamblado de la placa de cubierta* 50002883-001 TH5320U/TH5220D/TH5110D
Paquete de 12 placas de cubierta 50007297-001 TH5110D
medianas*
Paquete de 12 placas de cubierta 50007298-001 TH5320U/TH5220D/TH5110D
medianas*
* Úselo para cubrir las marcas que dejan los termostatos viejos.
Especificaciones
Rangos de temperatura
Calor: 40 °F a 90 °F (4,5 °C a 32 °C)
Frío: 50 °F a 99 °F (10 ºC a 37 °C)
Temperatura ambiente de funcionamiento
32 °F a 120 °F (0 ºC a 48,9 °C)
Temperatura de embalaje
-20 °F a 120 °F (-28,9 ºC a 48,9 °C)
Humedad relativa operativa
5% a 90% (no condensable)
Dimensiones físicas
TH5320U/TH5220D
3-9/16" de altura x 5-13/16" de ancho
x 1-1/2" de profundidad
91 mm de altura x 147 mm de ancho
x 38 mm de profundidad
TH5110D
3-7/16" de altura x 4-1/2" de ancho
x 1-5/16" de profundidad
86 mm de altura x 114 mm de ancho
x 33 mm de profundidad
Rangos eléctricos
Terminal Voltaje (50/60 Hz) Corriente
W Calefacción 20 a 30 V CA 0,02 a 1,0 A
(Powerpile) 750 mV CC 100 mA CC
W2 (Aux.) Calefacción 20 a 30 V CA 0,02 a 0,5 A
Y Refrigeración 20 a 30 V CA 0,02 a 1,0 A
Y2 Refrigeración 20 a 30 V CA 0,02 a 1,0 A
G Ventilador 20 a 30 V CA 0,02 a 0,5 A
O/B Conversión 20 a 30 V CA 0,02 a 0,5 A
E Calor de emergencia 20 a 30 V CA 0,02 a 1,0 A
L Salida 20 a 30 V CA 0,02 a 0,5 A

Transcripción de documentos

Installation Guide FocusPRO TH5000 Series TM Non-Programmable Digital Thermostat This manual covers the following models • TH5110D: For 1 Heat/1 Cool systems • TH5220D: For up to 2 Heat/2 Cool systems • TH5320U: For up to 3 Heat/2 Cool systems (Remove battery holder to find model number) System Types • Gas, oil, or electric heat with air conditioning • Warm air, hot water, highefficiency furnaces, heat pumps, steam, gravity • Heat only — two-wire systems, three-wire zone valves (Series 20), and normally open zone valves • Heat only with fan • Cool only • 750 mV heating systems Must be installed by a trained, experienced technician Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 ® U.S. Registered Trademark. Patents pending. Copyright © 2006 Honeywell International Inc. All rights reserved. 69-1922ES Installation Guide Wallplate installation 1. Separate wallplate from thermostat. It's easier to grasp the wallplate and remove it after completely removing the battery holder. 2. Mount wallplate as shown below. Remove battery holder. Pull here to remove wallplate from new thermostat. Drill 3/16" holes for drywall. Drill 7/32" holes for plaster. Wire hole Mounting screws Wall anchors Wallplate ! CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. ! MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.  FocusPRO TH5110 / TH5220 / TH5320 TM Power options Keep wires in this shaded area Remove factoryinstalled jumper only for twotransformer systems. Insert batteries for primary or backup power. Connect C for primary AC power (optional if batteries are installed). Wiring Terminal designations Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. Conventional Terminals: Heat Pump Terminals: Rc 24VAC power from cooling transformer Rc 24VAC power from cooling transformer R 24VAC power from heating transformer R W Heat relay (stage 1) O/B Changeover valve W2 Heat relay (stage 2) Y Y Compressor contactor (stage 1) C Compressor contactor (stage 1) Y2 Compressor contactor (stage 2) TH5320U only Y2 Compressor contactor (stage 2) G 24VAC power from heating transformer Fan relay Fan relay G 24VAC common. For 2 transformer systems, use common wire from cooling transformer. Aux Auxiliary heat relay* TH5110D TH5110D Rc Rc Y TH5110D C L Sends output when set to Em. Heat C 24VAC common G C W TH5220D G TH5110D Y G TH5220D Rc R O/B Y Y2 W2 G W C Y R Rc TH5320U Y Rc R W TH5220D Emergency heat relay* R*Aux and E terminals combined on TH5320U only. R C E C O/B L E Aux G C Y R Rc TH5220D TH5320U Y2 W2 G W C Y R Rc Y2 W2 G W C Y R Rc L Y2 Aux G TH5320U E G L E Aux G C Y R Rc C Y R Rc L Y2 Aux G E C Y R Rc TH5320U Y2 W2 G W C Y R Rc  Installation Guide Wiring Wiring guide — conventional systems Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 1H/1C System (1 transformer) G Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor C 24VAC common [3] W Heat relay G G Fan relay W C Y R Rc W C R Rc W C Y R Rc W C Y R Rc Heat-only System Rc R C W G W C Y R Rc Power [1] [R+Rc joined by jumper] 24VAC common [3] Heat relay G Heat-only System W C C Y R Rc W C R Rc W C Y R Rc W C Y R Rc G W C Y R Rc (Series 20) [5] W C Y W C CC YY Rc [R+Rc joined by jumper]G W R Series 20 valve terminal “R” [1] Y Series 20 valve terminal “W” C Y C 24VAC common [3] W C Y G W W CC Y W Series 20 valve terminal “B” Heat-only System R Rc R Rc RR Rc Rc R Rc R Rc R RR Rc Rc Rc G W C Y R Rc Rc C Y Y R R Rc C (normally open zone valve) [5] W Rc [R+Rc joined by jumper] R Power [1] Y Normally open zone valve G W C 24VAC common [3] Heat-only System with GFan W C GY W Rc R C Rc R C W W G W G R Rc G W C Power [1] [R+Rc joined by jumper] 24VAC common [3] C G R C Rc Y R Rc G Heat relay G C Y R Rc Fan relay R Rc G W C Cool-only Y2 GY WR C Rc Y W W2 C System R Rc R Rc C Y R Rc W C R Rc Y2 W2 G W C Y R Rc W C CPower R C Rc G GY WR Rc [1] R Rc G W Rc R [R+Rc by jumper] G Cjoined Y R Rc Y Y2 W2Compressor contactor Y2 W2 G Rc Y R Rc C GY WR C C W C24VAC common [3]Y2 W2 G Rc Y R W C G R CRc Y R Rc G G Y2 W2Fan G Wrelay C R Rc G W C Y R Rc W C Y R Rc W C Y R Rc W C Y R Rc C Y R Rc 2H/2C System G W C Y R Rc (1 transformer) Y2 W2 G W W C C Y Y Rc Y R Rc C GY Y W[6] R CRc Y2 Y2 W2 G W W2 C R G W C G W C Y R Rc G YY R G C Rc RR Rc G W W C C [1] Rc Rc Y2 W2Power R [R+Rc joined by jumper] Y Compressor contactor (stage 1) G Y2 WW2 C GY Y WR Rc Y R Rc R CRc Y2 W2 G W C Y C C Y2WW2C24VAC common [3] G C Y G WR CRc Y R Rc G C Y R Rc W Heat relay (stage 1) G Fan relay W2 (stage 2)Y2 W2 G W C Y G W CHeat Y R relay Rc Y2WW2C G GY W WR C CRcY Y R R Rc Rc Y2 Y2 W2 Compressor contactor (stage 2) R Rc Rc R R Rc R Rc R Rc R Rc 2H/2C System C Y Y R Rc R Rc C 1H/1C System (2 transformers) G W C Y R Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] Y Compressor contactor C 24VAC common [3, 4] W Heat relay G Fan relay Rc NOTES Wire specifications: Use 18- to 22-gauge thermostat wire. Shielded cable is not required. [1] Power supply. Provide disconnect means and overload protection as required. [2] Remove jumper for 2-transformer systems. [3] Optional 24VAC common connection. [4] Common connection must come from cooling transformer. [5] In Installer Setup, set system type to Heat Only. [6] In Installer Setup, set system type to 2Heat/2Cool Conventional.  (2 transformers) Y2 W2 G W C Y R Rc C Y R[6] Y2 W2 G W C Y R Rc Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] Y Compressor contactor (stage 1) G W C Y R Rc C 24VAC common [3, 4] W Heat relay (stage 1) G Fan relay W2 Heat relay (stage 2) Y2 Compressor contactor (stage 2) Rc See [notes] below [7] In Installer Setup, set changeover valve to O or B. [8] In Installer Setup, set system type to 2Heat/1Cool Heat Pump. [9] In Installer Setup, set system type to 2Heat/2Cool Heat Pump. [10] In Installer Setup, set system type to 3Heat/2Cool Heat Pump. [11] L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to Honeywell zoning panels to switch the panel to Emergency Heat. [12] Install field jumper between Aux and E if there is no emergency heat relay. G C Y R Rc FocusPRO TH5110 / TH5220 / TH5320 TM Wiring L E Aux G C Y R Rc L Aux G C Y R Rc G C Y R Rc G C Y R Rc L Y2 Aux G C Y R Rc Wiring guide — heat pump systems Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. E 1H/1C Heat Pump System Rc R Y C O/B G G Power [1] [R+Rc joined by jumper] Compressor contactor L E Aux G 24VAC common [3] Changeover valve [7] G Fan relay L 2H/1C Heat Pump System 2H/2C Heat Pump System C Y R Rc C Y R Rc C Y R Rc Aux G E C Y R Rc L E Aux G C Y R Rc (TH5220D only) [8] L Y2 G C Y R Rc Rc Power [1] R [R+Rc joined by jumper] L Aux G C Y R Rc Y Compressor contactor E G C Y R Rc C 24VAC common L[3]Y2 Aux E O/B Changeover valve [7] G C Y R Rc L Y2 G C Y R Rc G Fan relay Aux Auxiliary heat relay [12] E Emergency heat relay [12] L E Aux G C Y R Rc L Sends output when L Y2set Auxto G Em. C Heat Y R [11] Rc 3H/2C Heat Pump System E (TH5320U only) [10] Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor (stage 1) C 24VAC common [3] O/B Changeover valve [7] G Fan relay Aux/E Auxiliary/Emergency heat relay Y2 Compressor contactor (stage 2) L Sends output when set to Em. Heat [11] E 2H/1C Heat Pump System L Aux G L Y2 (TH5320U only) [9] L E Aux G C Y R Rc Rc Power [1] R [R+Rc joined by jumper] L Y2 Aux G C Y R Rc Y Compressor contactorE (stage 1) C 24VAC common [3] L Aux G C Y R Rc O/B Changeover valve [7] E G Fan relay Y2 Compressor contactor (stage 2) L Y2 Y R [11] Rc L Sends output when set toG Em.CHeat C Y R Rc E (TH5320U only) [8] Rc Power [1] R [R+Rc joined by jumper] L Y2 G C Y R Rc Y Compressor contactor C 24VAC common [3] O/B Changeover valve [7] L Y2 Aux G C Y R Rc G Fan relay E Aux/E Auxiliary/Emergency heat relay L Sends output when set to Em. Heat [11] See [notes] on page 4. Thermostat mounting Align the 4 tabs on the wallplate with slots on the back of the thermostat, then push gently until the thermostat snaps in place. Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation.  Installation Guide Installer setup Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. Function number Setting 1 Done Next Press s or t to change settings. Press NEXT to advance to the next function. Press DONE to exit and save settings. To begin, press and hold the s and FAN buttons until the display changes. Setup function 0 Settings & options (factory default in bold) Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 1 System type 0 1 2 3 4 5 6 7 8 9 10 1 heat/1 cool conventional 1 heat/1 cool heat pump (no aux. heat) Heat only — 2-wire systems, 3-wire zone valves (Series 20), and normally open zone valves Heat only with fan Cool only 2 heat/1 cool heat pump (with aux. heat) 2 heat/2 cool conventional 2 heat/1 cool conventional 1 heat/2 cool conventional 2 heat/2 cool heat pump (no aux. heat) - TH5320U only 3 heat/2 cool heat pump (with aux. heat) - TH5320U only 2 Changeover valve (O/B terminal) 0 1 Changeover valve (O/B terminal energized in cooling) Changeover valve (O/B terminal energized in heating) 3 Fan control (heating) 0 1 Gas or oil furnace — equipment controls fan in heating Electric furnace — thermostat controls fan in heating 5 Stage 1 heat cycle 5 rate (CPH: cycles/hour)* 1 3 9 For gas or oil furnaces of less than 90% efficiency For steam or gravity systems For hot water systems & furnaces of over 90% efficiency For electric furnaces 6 Stage 2 heat cycle rate/Auxiliary heat cycle rate (CPH)* 5 1 3 9 For gas or oil furnaces of less than 90% efficiency For steam or gravity systems For hot water systems & furnaces of over 90% efficiency For electric furnaces 7 Auxiliary heat cycle rate (CPH)* 5 1 3 9 For gas or oil furnaces of less than 90% efficiency For steam or gravity systems For hot water systems & furnaces of over 90% efficiency For electric furnaces 8 Emergency heat cycle 9 rate (CPH)* 1 3 5 For electric emergency heat For steam or gravity systems For hot water systems & furnaces of over 90% efficiency For gas or oil furnaces of less than 90% efficiency Only TH5320U for 3H/2C Heat Pumps *[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]  Continued on next page FocusPRO TH5110 / TH5220 / TH5320 TM Installer setup Setup function Settings & options (factory default in bold) Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 9 Stage 1 compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5 or 6 CPH] 10 Stage 2 compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5 or 6 CPH] 12 Manual/Auto changeover 0 1 2 Manual changeover (Heat/Cool/Off) Auto changeover (Heat/Cool/Auto/Off) Auto changeover only (Auto) 14 Temperature display 0 1 Fahrenheit Celsius 15 Compressor protection 5 Five-minute compressor off time [Other options: 0, 1, 2, 3 or 4-minute off time] 26 Auxiliary heat control 0 1 Comfort **See page 8 Economy 27 Heat temperature range stops 90 Max. heat temperature setting is 90 °F (32 °C) [Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)] 28 Cool temperature range stops 50 Min. cool temperature setting is 50 °��������� ���������� F (10 °�� ��� C) [Other options: 51 °F to 99 °F (10.5 °C to 37 °C)] Installer system test Test number System status 10 To begin, press and hold the s and t buttons until the display changes System test 0 Press s / t to turn system on/off. Press NEXT to advance to next test. Press DONE to terminate system test. System status Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 2 3 Heat and fan turn off. Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is set to 1 **See page 6 Stage 2 heat turns on Stage 3 heat turns on - TH5320U only 20 Emergency heating system 0 1 2 Heat and fan turn off Heat and fan turn on Stage 2 heat turns on (auxiliary heat) - TH5220D only 30 Cooling system 0 1 2 Compressor and fan turn off Compressor and fan turn on Stage 2 compressor turns on 40 Fan system 0 1 Fan turns off Fan turns on 10 Heating system ! 0 1 CAUTION: Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly  Installation Guide Special function Auxiliary heat control (Setup Function 26): • Comfort Setting: The thermostat will prioritize comfort over economy depending on heat pump performance, load conditions and whether the thermostat is calling for the heat pump. Raising the temperature just a few degrees will often activate the auxiliary heat. • Economy Setting: The thermostat will attempt to reach the temperature setting without activating the auxiliary heat. The thermostat will wait to activate the auxiliary heat depending on heat pump performance, load conditions and how many degrees the temperature setting is changed. Accessories & replacement parts Please contact your distributor to order replacement parts. Part Description Battery holder Battery holder Cover plate assembly* Cover plate assembly* 12 pack of small cover plates* 12 pack of medium cover plates* Part Number 50000951-001 50007072-001 50001137-001 50002883-001 50007297-001 50007298-001 Use With TH5110D TH5320U/TH5220D TH5110D TH5320U/TH5220D/TH5110D TH5110D TH5320U/TH5220D/TH5110D *Use to cover marks left by old thermostats. Specifications Temperature Ranges • Heat: 40° to 90°F (4.5° to 32°C) • Cool: 50° to 99°F (10° to 37°C) Electrical Ratings Operating Ambient Temperature • 32° to 120°F (0° to 48.9°C) W Heating 20-30 Vac 0.02-1.0 A (Powerpile) 750 mV DC 100 mA DC Shipping Temperature • -20° to 120°F (-28.9° to 48.9°C) Operating Relative Humidity • 5% to 90% (non-condensing) Physical Dimensions TH5320U/TH5220D • 3-9/16" H x 5-13/16" W x 1-1/2" D 91 mm H x 147 mm W x 38 mm D Terminal Voltage (50/60Hz) Running Current W2 (Aux) Heating 20-30 Vac 0.02-0.5 A Y Cooling 20-30 Vac 0.02-1.0 A Y2 Cooling 20-30 Vac 0.02-1.0 A G Fan 20-30 Vac 0.02-0.5 A O/B Changeover 20-30 Vac 0.02-0.5 A E Emergency heat 20-30 Vac 0.02-1.0 A L Output 20-30 Vac 0.02-0.5 A TH5110D • 3-7/16" H x 4-1/2" W x 1-5/16" D 86 mm H x 114 mm W x 33 mm D Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 http://yourhome.honeywell.com Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. ® U.S. Registered Trademark. © 2006 Honeywell International Inc. 69-1922ES M.S. 03-06 Guía de instalación Serie FocusPRO TH5000 TM Termostato digital no programable Este manual incluye los siguientes modelos: • TH5110D: Para sistemas de 1 calentador y 1 refrigerador • TH5220D: Para sistemas de 2 calentadores y 2 refrigeradores • TH5320U: Para sistemas de 3 calentadores y 2 refrigeradores (Quite el soporte de la batería para ver el número de modelo) Tipos de sistema • Sistema de calefacción a gas, a aceite o eléctrico con aire acondicionado • Calefacción de aire, agua caliente, sistemas de calefacción de alta efectividad, bombas de calor, vapor, gravedad • Sólo calor: sistemas de dos cables, válvulas de separación de tres cables (serie 20) y válvulas de separación normalmente abiertas • Sólo calor con ventilador • Sólo frío • Sistemas de calefacción de 750 mV Debe ser instalado por un técnico capacitado y experimentado Lea estas instrucciones atentamente. Si no sigue estas instrucciones, puede dañar el producto u ocasionar un riesgo. ¿Necesita asistencia? Para obtener asistencia relacionada con este producto, visite http://yourhome.honeywell.com o comuníquese con el número gratuito del Centro de atención al cliente de Honeywell, llamando al 1-800-468-1502 ® Marca registrada de los EE. UU. Patentes en trámite. © 2006, Honeywell International Inc. Todos los derechos reservados. 69-1922ES Guía de instalación Instalación de la placa para pared 1. Quite la placa para pared del termostato. 2. Monte la placa para pared como muestra la ilustración de abajo. Es más fácil quitar la placa para pared una vez que se extrae completamente el soporte de la batería. Extraiga el soporte de la batería. Hale de aquí para quitar la placa para pared del nuevo termostato. En tablarroca, realice agujeros de 3/16". En yeso, realice agujeros de 7/3". Tornillos de montaje Agujero para el cable Anclas de expansión Placa para pared ! PRECAUCIÓN: RIESGO ELÉCTRICO Puede ocasionar descargas eléctricas o dañar el equipo. Desconéctelo de la fuente de energía antes de comenzar la instalación. ! AVISO SOBRE EL MERCURIO En caso de que este producto reemplace a un control que contenga mercurio en tubo sellado, evite arrojar el viejo control a la basura. Póngase en contacto con la autoridad local para el manejo de desechos a fin de obtener instrucciones sobre el reciclado y la correcta eliminación de este tipo de desechos.  FocusPRO TH5110 / TH5220 / TH5320 TM Opciones de fuentes de energía Mantenga los cables en esta área sombreada Quite el puente instalado en la fábrica sólo en los sistemas con dos transformadores. Coloque las baterías para suministro de energía principal o de respaldo. Conecte C para suministrar corriente CA (opcional si las baterías están instaladas). Cableado Designación de terminales Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. Terminales convencionales: Rc 24 V CA desde el transformador del sistema de refrigeración R 24 V CA desde el transformador de la calefacción W Relé de calor (etapa 1) W2 Relé de calor (etapa 2) Y Interruptor automático del compresor (etapa 1) Y2 Interruptor automático del compresor (etapa 2) G Relé del ventilador C 24 V CA. Para los sistemas de 2 transformadores, utilice cables comunes desde el transformador de la refrigeración. TH5110D TH5110D Rc R Y Rc* Terminales Aux y E combinados únicamente en el R modelo TH5320U. Rc Y R C W Y O/B Y G C G C C TH5220D Terminales de la bomba de calor: Rc 24 V CA desde el transformador de la refrigeración R 24 V CA desde el transformador de la calefacción O/B Válvula inversora Y Interruptor automático del compresor (etapa 1) Y2 Interruptor automático del compresor (etapa 2) (únicamente TH5320U) G Relé del ventilador Aux Relé auxiliar de calor* E Relé de emergencia de calor* L Cuando se fija en Em. Heat, envía un flujo de aire caliente C 24 V CA TH5110D W Y2 W2 G W C Y R Rc TH5220D TH5320U G TH5220D TH5110D Rc R O/B C Y R Rc TH5220D L E Aux G G TH5320U Y2 W2 G W C Y R Rc Y2 W2 G W C Y R Rc TH5320U L E Aux G Y2 W2 G W C Y R Rc C Y R Rc C Y R Rc TH5320U L Y2 Aux G E  L Y2 Aux G E C Y R Rc Guía de instalación Cableado Guía de cableado: sistemas convencionales Las áreas sombreadas que aparecen abajo sólo se utilizan en el caso de los modelos TH5320U y TH5220D o según se indique. Sistema de 1 calentador G W C Y R Rc y 1 refrigerador (1 transformador) Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automático del compresor W C R Rc C 24 V CA [3] W Relé de calor G W C Y R Rc G Relé del ventilador G W Sistema de calefacción W C C Y Y únicamente W C Rc Electricidad [1] R [R+Rc unidos por un puente] G W C Y C 24 V CA [3] W C C Y W Relé de calor Sistema de calefacción G W C R Rc únicamente con ventilador G W C R Rc G W C Y R Rc Rc Electricidad [1] R [R+Rc unidos por un puente] C 24 V CA [3] G W C R Rc W G W CRelé deCRc calor GY R Y R Rc W C R Rc G C Y R Rc G Relé G WdelCventilador R Rc Sistema únicamente de refrigeración G W WR C C R Rc Y2 Rc W W2 C G Rc Y R G C G W W C C G W C Y Y2 W2 G Rc [1] Y R R Rc Rc W CElectricidad G C Y R Rc R [R+Rc unidos por un puente] Y Interruptor automático del compresor G VWCA C [3] R Rc C 24 Y2 W2 G W C Y2 Rc Rc Y R Rc W W2 C GY WR C CRelé R Rc Rc G W C ventilador Y2 W2 G W C Y del R R Rc R Rc R Rc R Rc R Rc R Rc Y2 W2 G W C Y R Rc W C Y R Rc W C R Rc Sistema de 2 Gcalentadores G W C W C Y R Rc y dos G refrigeradores G C Y R Y2 W2 WR CRc Y R Rc Rc Y2 W2 G W C C GY [6] (1 transformador) Y2 W2 G W C G W W C C Y Y R Rc R Rc G W C Y [1] R Rc Rc Y2 W2Electricidad R [R+Rc unidos G C Y Rpor Rc un puente] Y Y2WW2CInterruptor R Rc automático del compresor G C G W C Y R Rc Y2 W2 GY WR CRc Y R Rc G W C C [3] Y2 W2 G W C C24YV CA R Rc W Relé de calor (etapa 1) G Y2 W2 Relé G Wdel C ventilador Y R Rc W2 W CRelé de Rc calor (etapa 2) Y2 W2 G W C Y R Y2 W2 G W C Y R Rc Y2 Interruptor automático del compresor G W C Y R Rc Sistema de calefacción únicamente (Serie 20) [5] W Rc W C C Y R R Rc Rc [R+Rc unidos por un puente] G W C Y R Rc R Terminal “R” de la válvula de la serieC 20Y [1]R Rc Y Terminal “W” de la válvula de la W serie C 20 R Rc C 24 V CA [3] W CC YY RR Rc Rc W Terminal “B” de la válvula de la serie 20 G W C Y R Rc Sistema de calefacción W C Y R Rc únicamente (válvula de C Y R Rc G W C Y R Rc separación normalmente abierta) [5] Rc [R+Rc unidos por un puente] R Electricidad [1] C Y R Rc Y Válvula de separación normalmente abierta G W C Y R Rc C 24 V CA [3] G W C Y R Rc Y R Rc R Rc Y R Rc Y R Rc Y R Rc R Rc Y R Rc Y R Rc (etapa 1) Y R Rc Y R Rc Y R Rc (etapa 2) Sistema de 2 calentadores Y2 W2 G W C Y R Rc y dos refrigeradores Y2 W2 G W C Y R Rc C Y R Rc (2 transformadores) [6] Rc Electricidad (transformador de refrigeración) [1, 2] R Electricidad (transformador de calefacción) [1, 2] Y Interruptor automático del compresor (etapa 1) G W C Y R Rc C 24 V CA [3, 4] W Relé de calor (etapa 1) G Relé del ventilador W2 Relé de calor (etapa 2) Y2 Interruptor automático del compresor (etapa 2) Sistema de 1 calentador G W C Y R Rc y 1 refrigerador (2 transformadores) Rc Electricidad (transformador de refrigeración) [1, 2] R Electricidad (transformador de calefacción) [1, 2] Y Interruptor automático del compresor C 24 V CA [3, 4] W Relé de calor G Relé del ventilador Vea [notas] abajo NOTAS Especificaciones del cable: Use cable para termostato de calibre 18 a 22. No se requiere cable blindado. [1] Fuente de alimentación. Proporciona el medio de desconexión y la protección contra sobrecargas requeridos. [2] Para sistemas de 2 transformadores quite el puente. [3] Conexión común de 24 V CA opcional. [4] La conexión común debe provenir del transformador de refrigeración. [5] Durante la configuración de instalación, coloque el tipo de sistema en “Heat Only”. [6] Durante la configuración de instalación, coloque el tipo de sistema en Convencional de 2 calentadores y 2 refrigeradores.  [7] Durante la configuración de instalación, coloque la válvula inversora en la posición O o B. [8] Durante la configuración de instalación, coloque el tipo de sistema en Bomba de calor de 2 calentadores y 1 refrigerador. [9] Durante la configuración de instalación, coloque el tipo de sistema en Bomba de calor de 2 calentadores y 2 refrigeradores. [10] Durante la configuración de instalación, coloque el tipo de sistema en Bomba de calor de 3 calentadores y 2 refrigeradores. [11] El terminal L envía un flujo continuo de aire caliente cuando el termostato está en la posición Em. Heat. Conéctelo a los paneles de separación de Honeywell para cambiar a Em. Heat. [12] Coloque el puente de campo entre Aux y E si no existe un relé de emergencia de calor. G C Y R Rc FocusPRO TH5110 / TH5220 / TH5320 TM Cableado L E Aux G C Y R Rc Guía de cableado: sistemas de bomba de calor Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos L TH5320U y TH5220D o según se indique. Sistema de bomba de calor de 1 calentador G C Y R Rc y 1 refrigerador Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automático del compresor L E Aux G C Y R Rc C 24 V CA [3] O/B Válvula inversora [7] G C Y R Rc G Relé del ventilador C Y R Rc G C Y R Rc Sistema de bomba de calor de 2 calentadores y 2 refrigeradores L Y2 G C Y R Rc (únicamente TH5320U) [9] L E Aux G C Y R Rc Rc Electricidad [1] R [R+Rc unidos por un puente] L Y2 G C (etapa Y R Rc Y Interruptor automático delAux compresor 1) E C 24 V CA [3] Aux G C Y R Rc O/B Válvula inversora [7] L E G Relé del ventilador Y2 Interruptor automático del compresor (etapa 2) L Cuando se fija en Em. Heat, envía un flujo de aire caliente [11] L Y2 G C Y R Rc Sistema de bomba de L Aux G C Y R Rc E calor de 2 calentadores y 1 refrigerador L E Aux G C Y R Rc (únicamente TH5220D) [8] Rc Electricidad [1] L Y2 G C Y R Rc R [R+Rc unidos por un puente] Y Interruptor automático compresor L delAux G C Y R Rc E C 24 V CA [3] O/B Válvula inversora [7] G C Y R Rc L Y2 Aux G C Y R Rc G Relé del ventilador E Aux Relé auxiliar de calor [12] L Y2 G C Y R Rc E Relé de emergencia de calor [12] L Cuando se fija en Em. Heat, envía un flujo de aire L E Aux G C Y R Rc caliente [11] L Y2 Aux G Aux G E Sistema de bomba de calor de 3 calentadores y 2 refrigeradores L Y2 Aux G C Y R Rc E (únicamente TH5320U) [10] Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automático del compresor (etapa 1) C 24 V CA [3] O/B Válvula inversora [7] G Relé del ventilador Aux/E Relé de calor auxiliar/de emergencia Y2 Interruptor automático del compresor (etapa 2) L Cuando se fija en Em. Heat, envía un flujo de aire caliente [11] C Y R Rc Sistema de bomba de E calor de 2 calentadores L Aux G C Y R Rc y 1 refrigerador E (únicamente TH5320U) [8] Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automático del compresor L Y2 G C Y R Rc C 24 V CA [3] O/B Válvula inversora [7] G Relé del ventilador L Y2 emergencia Aux G C Y R Rc Aux/E Relé de calor auxiliar/de L Cuando se fija en Em. Heat,Eenvía un flujo de aire caliente [11] Vea las [notas] en la página 4. Montaje del termostato Alinee las 4 lengüetas de la placa de pared con las ranuras de la parte posterior del termostato y presione levemente hasta que el termostato encaje en su lugar. Coloque el excedente de cable en el interior de la abertura de la pared. Tape la abertura de la pared con un aislamiento no inflamable.  Guía de instalación Configuración de instalación Siga el procedimiento que aparece a continuación para configurar el termostato a fin de que se corresponda con el sistema de calefacción y refrigeración instalado, y seleccione las funciones según lo desee. Configuración Número de función 1 DONE Para comenzar, pulse y mantenga presionados los botones s y “FAN” hasta que cambie la pantalla. Funciones de la configuración 0 NEXT Presione s o t para cambiar la configuración. Presione NEXT para avanzar a la siguiente función. Presione DONE para salir y guardar la configuración. Configuraciones y opciones (las que vienen desde la fábrica aparecen en negrita) Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. 1 Tipo de sistema 0 1 2 3 4 5 6 7 8 9 10 1 calentador y 1 refrigerador convencional 1 bomba de calor con calentador y 1 refrigerador (sin calor aux.) Sólo calor — sistemas de dos cables, válvulas de separación de tres cables (serie 20) y válvulas de separación normalmente abiertas Sólo calor con ventilador Sólo frío Bomba de calor con 2 calentadores y 1 refrigerador (con calor aux.) 2 calentadores y 2 refrigeradores convencionales 2 calentadores y 1 refrigerador convencional 1 calentador y 2 refrigeradores convencionales Bomba de calor con 2 calentadores y 2 refrigeradores (sin calor aux.) únicamente en TH5320U Bomba de calor con 3 calentadores y 2 refrigeradores (con calor aux.) únicamente TH5320U 2 Válvula inversora (terminal O/B) 0 1 Válvula inversora (terminal O/B con energía durante la refrigeración) Válvula de inversora (terminal O/B con energía durante la calefacción) 3 Control del ventilador (calefacción) 0 Sistemas de calefacción a gas o a aceite (el equipo controla al ventilador para calefacción) Sistema de calefacción eléctrico (el termostato controla el ventilador para calefacción) Velocidad del ciclo térmico de la primera etapa (CPH: ciclos por hora)* 5 Velocidad de ciclo térmico/ ciclo de calor auxiliar de la etapa 2 (CPH)* 5 Velocidad de ciclo de calor auxiliar (CPH)* 5 5 6 7 Únicamente TH5320U para sistemas de bombas de calor de 3 calentadores y 2 refrigeradores Velocidad de ciclo de calor de emergencia (CPH)* 8 1 1 3 9 1 3 9 Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de más de un 90% de efectividad Para sistemas eléctricos Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de más de un 90% de efectividad Para sistemas eléctricos 1 3 9 Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de más de un 90% de efectividad Para sistemas eléctricos 9 1 3 5 Para calor de emergencia eléctrica Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de más de un 90% de efectividad Para sistemas de calefacción a gas o a aceite de menos de un 90% de efectividad * [Otras opciones de velocidad de ciclo: 2, 4, 6, 7, 8, 10, 11 ó 12 CPH]  Continúa en la página siguiente FocusPRO TH5110 / TH5220 / TH5320 TM Configuración de instalación Funciones de la configuración Configuraciones y opciones (las que vienen desde la fábrica aparecen en negrita) Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. 9 Rango de ciclos del compresor de la etapa 1 (CPH) 3 Recomendado para la mayoría de los compresores [Otras opciones de rango de ciclos: 1, 2, 4, 5 ó 6 CPH] 10 Rango de ciclos del compresor de la etapa 2 (CPH) 3 Recomendado para la mayoría de los compresores [Otras opciones de rango de ciclos: 1, 2, 4, 5 ó 6 CPH] 12 Conversión manual/ automática 0 1 2 Conversión manual (calor/frío/apagado) Conversión automática (calor/frío/automático/apagado) Sólo conversión automática (Auto) 14 Visor de temperatura 0 1 Fahrenheit Celsius 15 Protección del compresor 5 Tiempo de apagado de 5 minutos para el compresor [Otras opciones: tiempo de apagado de 0, 1, 2, 3 ó 4 minutos] 26 Control de calor auxiliar 0 1 Comfort **Vea la página 8 Economía 27 Limitador de rango de temperatura del sistema de calefacción 90 La configuración máxima de temperatura es de 90 °F (32 °C) [Otras opciones: 40 °F a 89 °F (4,5 °C a 31,5 °C)] 28 Limitador de rango de temperatura del sistema de enfriamiento 50 La configuración mínima de enfriamiento es de 50 °F (10 °C) [Otras opciones: 51 °F a 99 °F (10,5 °C a 37 °C)] Prueba del sistema Número de prueba Estado del sistema 10 Presione s / t para encender o apagar el sistema. Presione “NEXT” para avanzar hacia la próxima prueba. Presione “DONE” para finalizar la prueba del sistema. Para comenzar, pulse y mantenga presionados los botones s y t hasta que cambie la pantalla Prueba del sistema 0 Estado del sistema Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. 2 3 El calentador y el ventilador se apagan El calentador de la etapa 1 se enciende. El ventilador se enciende si la función 1 de la configuración se coloca en 1, 5, 9 o 10, o si la función 3 de la configuración se coloca en 1. **Vea la página 6 El calentador de la etapa 2 se enciende. El calentador de la etapa 3 se enciende únicamente en TH5320U 20 Sistema de calefacción de emergencia 0 1 2 El calentador y el ventilador se apagan El calentador y el ventilador se apagan El calentador de la etapa 2 se enciende (calor auxiliar) únicamente en TH5220D 30 Sistema de enfriamiento 0 1 2 El compresor y el ventilador se apagan El compresor y el ventilador se encienden El compresor de la etapa 2 se enciende 40 Sistema del ventilador 0 1 El ventilador se apaga El ventilador se enciende 10 Sistema de calefacción ! 0 1 PRECAUCIÓN: Durante la prueba, se desactiva la protección del compresor. Para evitar daños en el equipo, no permita que el compresor funcione a velocidades altas.  Guía de instalación Funciones especiales Control de calor auxiliar (configuración 26): • Configuración comfort: El termostato priorizará el confort sobre la economía dependiendo del funcionamiento de la bomba de calor, de las condiciones de carga y de si el termostato requiere el uso de la bomba de calor. El incremento de la temperatura en unos pocos grados a menudo activará el calentador auxiliar. • Configuración económica: El termostato intentará alcanzar la temperatura de configuración sin activar el calentador auxiliar. El termostato esperará hasta activar el calentador auxiliar dependiendo del funcionamiento de la bomba de calor, de las condiciones de carga y de la cantidad de grados que varíe la configuración. Accesorios y piezas de repuesto Póngase en contacto con su distribuidor para solicitar piezas de repuesto. Descripción de las piezas Soporte de la batería Soporte de la batería Ensamblado de la placa de cubierta* Ensamblado de la placa de cubierta* Paquete de 12 placas de cubierta medianas* Paquete de 12 placas de cubierta medianas* Número de pieza 50000951-001 50007072-001 50001137-001 50002883-001 50007297-001 Se usa con TH5110D TH5320U/TH5220D TH5110D TH5320U/TH5220D/TH5110D TH5110D 50007298-001 TH5320U/TH5220D/TH5110D * Úselo para cubrir las marcas que dejan los termostatos viejos. Especificaciones Rangos de temperatura • Calor: 40 °F a 90 °F (4,5 °C a 32 °C) • Frío: 50 °F a 99 °F (10 ºC a 37 °C) Rangos eléctricos Terminal Voltaje (50/60 Hz) Corriente Temperatura ambiente de funcionamiento • 32 °F a 120 °F (0 ºC a 48,9 °C) W Calefacción 20 a 30 V CA 0,02 a 1,0 A (Powerpile) 750 mV CC 100 mA CC Temperatura de embalaje • -20 °F a 120 °F (-28,9 ºC a 48,9 °C) W2 (Aux.) Calefacción 20 a 30 V CA 0,02 a 0,5 A Y Refrigeración 20 a 30 V CA 0,02 a 1,0 A Y2 Refrigeración 20 a 30 V CA 0,02 a 1,0 A G Ventilador 20 a 30 V CA 0,02 a 0,5 A O/B Conversión 20 a 30 V CA 0,02 a 0,5 A E Calor de emergencia 20 a 30 V CA 0,02 a 1,0 A L Salida 0,02 a 0,5 A Humedad relativa operativa • 5% a 90% (no condensable) Dimensiones físicas TH5320U/TH5220D • 3-9/16" de altura x 5-13/16" de ancho x 1-1/2" de profundidad 91 mm de altura x 147 mm de ancho x 38 mm de profundidad 20 a 30 V CA TH5110D • 3-7/16" de altura x 4-1/2" de ancho x 1-5/16" de profundidad 86 mm de altura x 114 mm de ancho x 33 mm de profundidad Soluciones para automatización y control Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V4Z9 http://yourhome.honeywell.com Impreso en los EE. UU., en papel reciclado que contiene por lo menos un 10% de fibras de papel reciclable. ® Marca registrada de los EE. UU. © 2006, Honeywell Internacional Inc. 69-1922ES M.S. 03-06
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Honeywell FOCUSPROTM TH5000 Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para