IO-Link Data Dictionary VSi HD series
21.10.01.00176/00 21.04.2022
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
7…0 Most significant 8 bits of sensor measurement value (mbar)
7…2 Least significant 6 bits of sensor measurement value (mbar)
1 Boolean ro Logic state of switch point 2
0 Boolean ro Logic state of switch point 1
Subindex
dec hex dec
16 0x0010 0 1...32 bytes ro J. Schmalz GmbH Manufacturer designation
17 0x0011 0 1...32 bytes ro Innovative Vacuum Solutions Vendor text
18 0x0012 0 1...32 bytes ro VSi / VSi-D General product name
19 0x0013 0 1...32 bytes ro VSi / VSi-D Product variant name
20 0x0014 0 1...32 bytes ro VSi V M12-4 Order-code
21 0x0015 0 9 bytes ro 000000001 Serial number
22 0x0016 0 2 bytes ro 00 Hardware revison
23 0x0017 0 4 bytes ro 1.11 Firmware revision
240 0x00F0 0 20 bytes ro Unique device identification number
241 0x00F1 0 11 bytes ro Type code of device features (see IODD)
250 0x00FA 0 14 bytes ro 10.06.02.* Order-number
251 0x00FB 0 2 bytes ro 00 Article revision
252 0x00FC 0 3 bytes ro Date code of production (month, year)
254 0x00FE 0 1...64 bytes ro VSi V M12-4 Detailed type description of the device
24 0x0018 0 1...32 bytes rw *** User string to store location or tooling information
25 0x0019 0 1...32 bytes rw *** User string to store function
26 0x001A 0 1...32 bytes rw *** User string to store location
242 0x00F2 0 1…64 bytes rw *** User string to store identification name from schematic
246 0x00F6 0 1…64 bytes rw *** User string to store geolocation from handheld device
247 0x00F7 0 1…64 bytes rw *** User string to store web link to IODD file
249 0x00F9 0 1…32 bytes rw *** User string to store storage location
253 0x00FD 0 1…16 bytes rw *** User string to store date of installation
2 0x0002 0 1 byte 5, 65, 130, 165,
66, 167, 168, 169 wo
0x05 (dec 5): Force upload of parameter data into the master
0x41 (dec 65): Execute single-value teach for currently selected SPx
0x81 (dec 129): Application Reset
0x83 (dec 131): Back-To-Box
0xA5 (dec 165): Calibrate sensor
0xA7 (dec 167): Reset erasable counters ct1 and ct2
0xA8 (dec 168): Reset min/max values of supply voltage
0xA9 (dec 169): Reset min/max values of sensor
58 0x003A 0 1 byte 1, 2 rw 1 Select switch point 1 or 2 for teaching
59 0x003B 0 1 byte ro
Result of last teach-in command:
0x00 = Channel changed
0x07 = Teach-in failed
0x11 = Teach-in successful
73 0x0049 0 1 byte 0 - 1 rw 0 0 = PNP
1 = NPN
60 0x003C 1 2 bytes
999 > SP1 > RP1
rw 750 Unit mbar
60 0x003C 2 2 bytes
0 < RP1 < SP1
rw 600 Unit mbar
61 0x003D 1 1 byte 0 - 1 rw 0 0 = Non-inverted / Normally open
1 = Inverted / normally closed
61 0x003D 2 1 byte 2, 3, 128, 129 rw 3
2 = Window mode
3 = Two-Point mode
128 = Condition monitoring Mode
129 = Diagnostic mode
61 0x003D 3 2 bytes rw 20 Unit mbar
75 0x004B 1 2 bytes 0 - 999 rw 0 Unit ms
75 0x004B 2 2 bytes 0 - 999 rw 0 Unit ms
62 0x003E 1 2 bytes
999 > SP2 > RP2
rw 550 Unit mbar
62 0x003E 2 2 bytes
0 < RP2 < SP2
rw 500 Unit mbar
63 0x003F 1 1 byte 0 - 1 rw 0 0 = NO
1 = NC
63 0x003F 2 1 byte 2, 3, 128, 129 rw 3
2 = Window Mode
3 = Two-Point Mode
128 = Condition Monitoring
129 = Diagnostic Mode
63 0x003F 3 2 bytes rw 20 Unit mbar
80 0x0050 1 2 bytes 0 - 999 rw 0 Unit ms
80 0x0050 2 2 bytes 0 - 999 rw 0 Unit ms
108 0x006C 0 2 bytes 0 - 999 rw 200 Unit mbar/sec
40 0x0028 0 2 bytes ro Copy of currently active process data input
64 0x0040 1 2 bytes ro Actual sensor value
Device Settings
Teach-In Status
Sensor Value
Signal Type
Installation Date
Switching Point 1
Application Specific Tag
Process Data Input
ISDU Parameters
PD In Byte 0 Vacuum in mbar, MSB
Data Type
SIO-Mode
Value Range
Vendor Text
Bits
Function Tag
Process Data Input
Process Data Output
IO-Link Bitrate
Minimum Cycle Time
None
2.3 ms
Firmware Revision
Product ID
IODD Web Link
Size
Access
Location Tag
Identification
ro
PD In Byte 1
IO-Link Implementation
Process Data
Remark
Switching Point 2
Name
Switch Point 2 - Lower Threshold
Switch Point 2 - Mode
Switch Point 1 - Upper Threshold
Switch Point 1 - Lower Threshold
Switch Point 1 - Logic
Switch Point 1 - Mode
Switch Point 1 - Window Hysteresis
Switch Point 1 - Switch-on delay
Switch Point 2 - Upper Threshold
Device Management
Equipment Identification
Switch Point 2 - Window Hysteresis
Device Localization
Process Settings
Monitoring
AccessParameter
Hardware Revision
Product Text
Initial Settings
Switch Point 2 - Switch-off delay
Switch Point 1 - Switch-off delay
Remark
Switch Point 2 - Logic
Default Value
Serial Number
IO-Link Revision
Production Date
ISDU Index
Device Features
Product Name
Unique ID
Geolocation
Article Number
Article Revision
Switch Point 2 - Switch-on delay
System Command
Detailed Product Text
Teach-In Channel
Switch Point 1
Switch Point 2
Storage Location
Parameter
Vendor Name
Process Data In Copy
Observation
Permissible Leakage Rate
Condition Monitoring [CM]
Commands
IO-Link Profile Smart Sensor Profile with 2 Binary Data Channels, 1 Process Data Variable, Teach-In and Diagnosis
38.4 kBit/sec (COM2)
2 bytes
Special Values
VSi V: 10000 = Overflow, 16383 = Underflow (pressure)
Vacuum in mbar, LSB
VSi V: 14-bit unsigned integer
234 (0x00EA)
100616 (0x018908)
Yes
1.0
Device ID
Vendor ID
Process Data
J. Schmalz GmbH 1 of 2 VSi Data Dictionary