62 0x003E
1
2
2
2
bytes
bytes
999 >= SP2 > rP2
SP2 < SP1
999 >= FH2 > FL2+Hy2
FH2 < FH1
rw
rw
550
530
Unit: 1mbar
Unit: 1mbar
63 0x003F
2
1
1
2
byte
bytes
bytes
0-1
2, 3
0 <= Hy2 < FH2-FL2
rw
rw
rw
0
3
10
0 = NO
1 = NC
2 = Window Mode
3 = Two-Point Mode
Unit: 1mbar
64 0x0040
1
2
2
2
bytes
bytes
-
ro
ro
-
Unit: 1mbar
Unit: 1mbar
66 0x0042
1
2
3
2
2
2
bytes
bytes
bytes
-
ro
ro
ro
-
Unit: 0.1V
Unit: 0.1V
Unit: 0.1V
564 0x0234 0 1 byte - ro - 0x00 = SIO mode
0x11 = IO-Link
36 0x0024 0 1 byte - ro 0
0 = Device is operating properly (= Green)
1 = Maintenance required (= Yellow)
2 = Out of Spec (= Orange)
3 = unused
4 = Failure (= Red)
Information about currently pending events (Event-List)
130 0x0082 0 2 bytes - ro 0
Bit 0 = IO-Link startup check: data corruption
Bit 1 = Switch cycles too fast
Bit 2 = Primary voltage too low
Bit 3 = Primary voltage too high
Bit 4 = reserved
Bit 5 = reserved
Bit 6 = reserved
Bit 7 = reserved
Bit 8 = Short circuit at OUT2
Bit 9 = reserved
Bit 10 = reserved
Bit 11 = Measurement range overrun
Bit 12 = reserved
Bit 13 = reserved
Bit 14 = reserved
Bit 15 = IO-Link communication interruption
146 0x0092 0 2 bytes - ro 0
Bit 0 reserved
Bit 1 = Evacuation time above limit [t-1]
Bit 2 reserved
Bit 3 = SP1 not reached
Bit 4 reserved
Bit 5 = Primary Voltage US out of operating range
140 0x008C 0 4 bytes - ro 0 Apply atmosphere (non-erasable)
141 0x008D 0 4 bytes - ro 0 Counter for switch-on switch point 2 (non-erasable)
142 0x008E 0 4 bytes - ro 0 Switch-on counter for switch point 1 (non-erasable)
143 0x008F 0 4 bytes - ro 0 Apply atmosphere (erasable)
144 0x0090 0 4 bytes - ro 0 Counter for switch-on switch point 2 (erasable)
145 0x0091 0 4 bytes - ro 0 Switch-on counter for switch point 1 (erasable)
148 0x0094 0 2 bytes - ro 0 Unit: 1ms
Time from suction start to reaching SP2
149 0x0095 0 2 bytes - ro 0 Unit: 1ms
Time from reaching SP2 to reaching SP1
171 0x00AB 0 2 bytes - ro 0 Unit: 1ms
Time from apply vacuum on to vacuum < 20 mbar
0 0x10 Device is working optimally
6144 - Calibration offset 0 set successfully
6145 0x22 Sensor value too high or too low, offset not changed
20736 0x42 Primary supply voltage (US) too low
6152 0x22 Condition monitoring: evacuation time t1 is above limit [t-1]
20752 0x42 Primary supply voltage (US) too high
6154 0x22
Condition monitoring: vacuum level SP1 was never reached during
6156 0x22 Condition Monitoring: primary supply voltage US outside of operating range
6161 0x82 Internal error, user data corrupted
36096 0x82 Output is connect with counterpotential
36097 0x42 Switch cycles too fast
35872 0x82 Measured vacuum value too high, sensor fault
Meaning
Coding of IO-Link Events
Extended Device Status ID
Device status
Event Type
Remark
Counters
IO-Link
Condition Monitoring [CM]
Condition monitoring
Monitoring
Diagnosis
Switch-on counter for switch point 2
Apply atmosphere counter
Observation
Event name
0x1808 Warning Warning CM: Evacuation time above limit
0x5110 Critical condition Warning
System vacuum live
System vacuum min
System vacuum max
Apply atmosphere counter
Device Status
(= IO-Link Event Code)
Active errors
Detailed device status
Communication mode
Primary supply voltage live
Primary supply voltage min
Primary supply voltage max
Switch-on counter for switch point 1
Switch-on counter for switch point 1
Extended Device Status Type
Counter for switch-on switch point 2
Timing
Evacuation time t0 of last suction-
cycle
Evacuation time t1 of last suction-
cycle
Error General power supply fault
Switchpoint 2
Switch Point 2 - Logic
Switch Point 2 - Mode
Switch Point 2 - Window hysteresis
Switch Point 2- Upper threshold
SP2 / FH2
Switch Point 2 - Lower threshold
rP2 / FL2
0x0000 Everything OK (no IOL event) Everything OK
0x1800 (IOL event only) Notification Vacuum calibration OK
0x8D01 Critical condition
Primary supply voltage over-run
Warning Notification
hex
Drop-off time t3 of last Drop-off
0x1811 Defect/fault Error Data corruption
Vacuum calibration failed
0x180A Warning Warning CM: SP1 not reached
0x180C Warning Warning CM: Primary supply voltage out of optimal range
0x1801
0x5100 Critical condition
Error Switch cycles too fast
0x8D00 Critical condition (no IOL event) Short circuit at OUT2
0x8C20 Defect/fault Error Measurement range overrun