In accordance with our policy of continuous product development and improvement,
this information is subject to change at any time without notice.
EI218579 Issued (JMT/KAK) 2 January, 2001
Manitowoc Beverage Equipment
2100 Future Drive Sellersburg, IN 47172-1868
Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922
www.manitowocbeverage.com
Foodservice Group
Specifications
Model 00217314 00218578 00214165 00218579
Supply Voltage 230 VAC 230 VAC 230 VAC 230 VAC
Output Voltage 1 26 VAC 26 VAC 26 VAC 26 VAC
Output Voltage 2 NA NA 26 VAC 26 VAC
Output 1 (VA) 40 VA 40 VA 40 VA 40 VA
Output 2 (VA) NA NA 40 VA 40 VA
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Power Factor (cos j) 1 1 1 1
Degree of Protection IP31 IP31 IP31 IP31
Max. Ambient temperature 40°C 40°C 40°C 40°C
Normal Duty Cycle @ 25°C (all models) 5 minutes “on”, 5 minutes “off”.
Multiplex Beverage Equipment Installation Instructions for
Transformer Assemblies
General
These Transformer Assemblies are classified as Class 1 short-circuit proof safety isolating transformers. They are
designed to provide safety extra-low voltage for Multiplex Dispensing Stations and are intended for indoor use only.
Note: If the external flexible cord of this transformer is damaged, it shall be replaced only by an authorized agent
of Multiplex Company, Inc. in order to avoid a hazard.
Installation
1. Determine horizontal location for mounting transformer within 2 m of dispensing tower. An appropriate receptacle is
required within 2 m of transformer.
2. Position the transformer temporarily in desired location and transfer mark mounting hole locations.
3. Drill two or four 4 mm diameter holes at the hole locations.
4. Place transformer assembly in position and secure with screws provided.
5. Plug dispensing tower into output cord receptacle. Plug transformer power supply cord into the appropriate receptacle.