Greenlee DM-860A Digital Multimeter Manual de usuario

Categoría
Medir, probar
Tipo
Manual de usuario

Este manual también es adecuado para

INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D’INSTRUCTIONS
Read and understand all of the instructions and safety information in this
manual before operating or servicing this tool.
Lea y entienda todas las instrucciones y la información sobre seguridad
que aparecen en este manual, antes de manejar estas herramientas o
darles mantenimiento.
Lire attentivement et bien comprendre toutes les instructions et les
informations sur la sécurité de ce manuel avant d’utiliser ou de procéder à
l’entretien de cet outil.
Register this product at www.greenlee.com / Registre este producto en www.greenlee.com
Enregistrez votre produit en ligne, www.greenlee.com
DM-860A
Digital
Multimeter
Multímetro
digital
Multimètre
numérique
52056270 REV 2 © 2019 Greenlee Tools, Inc. 9/19
2
Description
The Greenlee DM-860A Digital Multimeter is a hand-held testing device with the following measure-
ment capabilities: AC and DC voltage, AC and DC current, percent of loop current, two channels of
temperature (K-type thermocouples), frequency, duty cycle, resistance, conductance, and capacitance.
It also checks diodes and verifies continuity.
The DM-860A features a bar graph display that responds more quickly than the numeric display—
useful for detecting faulty contacts, potentiometer clicks, and signal spikes. An optional optically
isolated computer interface with software facilitates the recording of readings from the meter to a
computer.
Other specialized functions and capabilities include:
• Dual display shows two measurements, such as AC voltage and frequency, at the same time.
• Beep-Jack™ audible warning alerts the user with a beep and an error message on the LCD if the
test lead is plugged into the mAµA or A input terminal while the selector switch is not in the mAµA
or A position.
• AC bandwidth to 100 kHz for voltage or 20 kHz for current.
• MAX/MIN function which stores the maximum, minimum, and average.
• Crest capture mode to capture voltage or current signal peaks.
• Selectable between 50,000 or 500,000 counts resolution when measuring DC voltage.
• Relative zero mode.
• Automatic or manual ranging.
• Intelligent automatic power off.
• Backlighted LCD for reading in dim conditions.
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction
manual and any markings on the tool provide information for avoiding hazards and unsafe practices
related to the use of this tool. Observe all of the safety information provided.
Purpose of This Manual
This instruction manual is intended to familiarize all personnel with the safe operation and maintenance
procedures for the Greenlee DM-860A Digital Multimeter.
Keep this manual available to all personnel. Replacement manuals are available upon request at no
charge at www.greenlee.com.
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
DM-860A
3
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which could result in an
injury or property damage. The signal word, defined below, indicates the severity of the hazard.
The message after the signal word provides information for preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage.
Read and understand this material before operating or servicing this
equipment. Failure to understand how to safely operate this tool could result in
an accident causing serious injury or death.
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Important Safety Information
All specifications are nominal and may change as design improvements occur. Greenlee Tools, Inc. shall not be liable
for damages resulting from misapplication or misuse of its products.
® Registered: The color green for electrical test instruments is a registered trademark of Greenlee Tools, Inc.
Beep-Jack is a trademark of BTC.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
KEEP THIS MANUAL
4
Important Safety Information
Electric shock and fire hazard:
• Do not expose this unit to rain or moisture.
• Do not use the unit if it is wet or damaged.
• Only use the test leads provided with the equipment or UL Listed Probe Assembly with same rating
or better.
• Inspect the test leads or accessory before use. They must be clean and dry, and the insulation
must be in good condition. Do not use the test lead if the contrasting inner layer of insulation is
visible.
• Use this unit for the manufacturer’s intended purpose only, as described in this manual.
Anyotheruse can impair the protection provided by the unit.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
• Do not apply more than the rated voltage between any two input terminals, or between any input
terminal and earth ground.
• Do not contact the test lead tips or any uninsulated portion of the accessory.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
• Do not operate with the case open.
• Before opening the case, remove the test leads from the circuit and shut off the unit.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
The fuses are an integral part of the overvoltage protection. When fuse replacement is necessary,
refer to “Specifications” for the correct type, size, and capacity. Using any other type of fuse will void
the overvoltage protection rating of the unit.
Failure to observe this warning could result in severe injury or death.
DM-860A
5
Important Safety Information
Electric shock hazard:
• Unless measuring voltage, current, or frequency, shut off and lock out power. Make sure that all
capacitors are discharged. Voltage must not be present.
• Set the selector and connect the test leads so that they correspond to the intended measurement.
Incorrect settings or connections can result in a blown fuse.
• Using this unit near equipment that generates electromagnetic interference can result in unstable
or inaccurate readings.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
Do not change the measurement function while the test leads are connected to a component or
circuit.
Failure to observe this precaution may result in injury and can damage the unit.
Electric shock hazard:
• Do not attempt to repair this unit. It contains no user-serviceable parts.
• Do not expose the unit to extremes in temperature or high humidity. Refer to “Specifications.”
Failure to observe these precautions may result in injury and can damage the unit.
6
Identification
1. Display LCD and bar graph
2. Feature Buttons Refer to explanations under “Using the Features”
3. Selector Selects a function or turns power OFF
4. A Positive input terminal for high current measurements;
negative input terminal for T2
5. mA µA Positive input terminal for low current measurements;
positive input terminal for T2
6. COM Negative, common, or ground input terminal for all measurements
7. ΩV Positive input terminal for all measurements except current
1
3
2
4 7
5 6
Symbols on the Unit
Warning—Read the instruction manual
Double insulation
DM-860A
7
Primary Display
8.
Bar graph element
9. Polarity indicator for bar graph
10. Bar graph scale
11. Relative zero function is enabled.
12. VFD VFD function is enabled.
13. Polarity indicator
14. 8.8.8.8.88 Numeric display
15. T1-T2 T1, T2, or T1-T2 function is enabled.
16. AC measurement is selected.
17. DC measurement is selected.
18. MAX Maximum value being recorded
or displayed.
19. MIN Minimum value being recorded
or displayed.
20. AVG Average value being recorded
or displayed.
21. Record function is enabled.
22. Crest capture function is enabled.
23. Hold function is selected.
24. Automatic ranging is enabled.
25. Continuity
26. Low battery
27. } Overload symbol
(bar graph display)
28. 5 Bar graph maximum range
indicator
29. D% Duty cycle function is enabled.
30. k Kilo (10
3
)
31. M Mega (10
6
)
32. Ω Ohm
33. Hz Hertz (frequency in
cycles per second)
34. dBm Decibel
35. m Milli (10
-3
)
36. µ Micro (10
-6
)
37. V Volt
38. A Ampere
39. n Nano (10
-9
)
40. F Farad
41. S Siemen
Secondary Display
42. %4-20mA Industrial process control loop
current function is enabled.
43. µ Micro (10
-6
)
44. m Milli (10
-3
)
45. A Ampere
46. V Volt
47. M Mega (10
6
)
48. k Kilo (10
3
)
49. Hz Hertz (frequency in
cycles per second)
50. 8.8.8.8 Numeric display
51. T2 T2 function is enabled.
52. AC measurement is selected.
53. Polarity indicator
Display Icons
24
21-23
18-20
16-17
15
12
11
10
8-9
13-14
47-49
43-46
42
29-41
27
28
2625
51-53
50
8
Dual Digital Display: This meter can display two measurements, such as AC voltage and frequency,
at the same time. Display combinations are shown using large symbols to indicate the measurement
on the primary display and small, raised symbols to indicate the measurement on the secondary
display. For example, “VAC
Hz
means the primary display contains the AC voltage measurement, and
the secondary display contains the frequency measurement.
VFD ~V and VFD Hz: These functions use filtering and noise-rejection algorithms to make accurate
voltage and frequency measurements on most variable frequency drives. The voltage measure-
ment automatically selects the 500 volt range. Use the RANGE button to select other ranges only
when needed. The sensitivity for VFD frequency measurements depends on voltage range and input
frequency. Refer to “Frequency – Line Level” in the “Accuracy” section of this manual.
SELECT: Press momentarily to toggle between functions, measurement modes, or display modes.
The last used setting becomes the default when that function is selected again. To change the
default, select a new setting. The setting will be stored in nonvolatile memory.
RANGE: Press once to enter the manual ranging mode. The icon will disappear from the
display. Press repeatedly to step through the ranges. Press and hold to return to the automatic
ranging mode.
Note: When using CREST, REC, HOLD, or ∆ mode, pressing RANGE will cause the meter to exit that
mode.
∆: Finds the difference between two measurements. While taking a measurement, press to set the
display to zero. The icon will appear on the display. Take the second measurement. The value on
the display will be the difference between the two measurements. Press again to exit this mode.
This feature applies to the main display only.
HOLD : Press momentarily to hold the present value on the display. Press again to exit this mode.
This feature does not affect the bar graph.
CREST : Press momentarily to activate the crest recording mode.The input value is measured
every 1 ms in this mode. and “MAX” will appear on the display. The LCD will display the maximum
crest value. The meter will beep whenever the maximum or minimum is updated. Press repeatedly to
select the desired display: maximum or minimum crest value. Press and hold to exit this mode.
The automatic power off feature is disabled when using this function.
Note: When using the CREST function, pressing RANGE will cause the meter to exit this mode.
REC : Press momentarily to activate the MAX/MIN/AVG recording mode. The input value is
measured every 50 ms in this mode. “MAX MIN” and “AVG” will appear on the display. The LCD will
display the actual input value. The meter will beep whenever the maximum or minimum is updated.
Press repeatedly to select the desired display: maximum, minimum, average, or actual input. Press
and hold to exit this mode.
The automatic power off feature is disabled when using this function.
Note: When using the REC function, pressing RANGE will cause the meter to exit this mode.
: Press and hold until backlight illuminates. Press and hold again to turn off. The backlight
automatically turns off after approximately 30 seconds to extend battery life.
Using the Features
DM-860A
9
Using the Features (cont’d)
dBm-Ω: The reference impedance is displayed for 1 second after selecting the dBm function.
Momentarily press dBm-Ω to change the reference impedance. Refer to the “Specifications” section
for the available values.
Note: This is an AC voltage measurement calculated according to the formula
dBm = 20 x log (measured voltage / reference voltage
The reference voltage is the voltage that causes 1 mW of power to be dissipated in the selected
reference impedance.
T1-T2: Press momentarily to select the desired temperature display: T1, T2, T1
T2
, or T1-T2
T2
.
500000: Press and hold to toggle between 50,000 counts fast mode and the 500,000 counts high
resolution mode for DC voltage measurements.
Intelligent Automatic Power Off (APO): To extend battery life, the meter shuts itself off after
approximately 17 minutes of inactivity. Inactivity occurs when buttons are not pressed or the selector
is not turned. The meter will not enter APO when there are significant readings of over 10% of the
range or non-OL readings for resistance and continuity. To restore power, press SELECT, RANGE, ,
or HOLD or turn the selector to OFF and back on again. To disable this feature, press SELECT while
turning the meter on.
Disabling the Beeper: Hold down the RANGE button while turning the meter on to temporarily
disable the beeper feature. Turn the selector to OFF and then back on to enable the beeper.
Hz: Frequency can be measured in most voltage and current settings of the selector. Press SELECT
until “Hz” appears in the primary or secondary display, as desired. The sensitivity of the Line Level
Frequency function varies with measurement range. Refer to “Specifications.” Auto-ranging mea-
surements usually set the best trigger level. If the frequency reading becomes unstable or is blank,
press the RANGE button to select another trigger level.
%4-20mA: This calculated value is one of three available options for the secondary display when
measuring DC milliamps. It is useful for 4-20 mA industrial process control loop applications. A
reading of 4 mA on the primary display gives a 0% reading on the secondary display, 12 mA gives
50%, 20 mA gives 100%, etc.
10
AC Measurement
AC measurements are usually displayed as RMS (root mean square) values. The RMS value is equal to
the value of a DC waveform, which would deliver the same power if it replaced the time-varying wave-
form. Two AC measurement methods are average-responding RMS calibrated and true RMS-reading.
The average-responding RMS calibrated method takes the average value of the input signal after full
wave rectification, multiplies it by 1.11, and displays the result. This method is accurate if the input
signal is a pure sine wave.
The true RMS-reading method uses internal circuitry to read the true RMS value. This method is accu-
rate, within the specified crest factor limitations, whether the input signal is a pure sine wave, square
wave, triangle wave, half wave, or signal with harmonics. The ability to read true RMS provides much
more measurement versatility. The Greenlee DM-860A is a true RMS meter.
The Waveforms and Crest Factors table shows some typical AC signals and their RMS values.
Waveforms and Crest Factors
Waveform
RMS Value 100 100 100 100
Average Value 90 100 87 64
Crest Factor*
(x)
1.414 1 1.73 2
* The crest factor is the ratio of the peak value to the RMS value; it is represented by the Greek
letter x.
AC + DC True RMS
AC + DC true RMS calculates both of the AC and DC components given by the expression
when making measurements and responds accurately to the total effective RMS value regardless of the
waveform. Distorted waveforms with the presence of DC components and harmonics may cause:
• Transformers, generators, and motors to overheat
• Circuit breakers to trip prematurely
• Fuses to blow
• Neutrals to overheat due to the triplen harmonics present on the neutral
• Bus bars and electrical panels to vibrate
DM-860A
11
AC Bandwith
AC bandwidth of a digital multimeter (DMM) is the range of frequencies over which AC measurements
can be made within the specified accuracy. It is the frequency response of the AC functions—not of
the frequency measurement functions. A DMM cannot accurately measure the AC value with frequency
spectrums beyond the AC bandwidth of the DMM. Therefore, wide AC bandwidth plays an impor-
tant role in high performance DMMs. Complex waveforms, noise, and distorted waveforms contain
frequency components that are much higher than the fundamental; for example, high frequency noise
on a 50/60 Hz power line.
Operation
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Self-Diagnostic Mode
The message “rE-O” may appear when the meter is turned on. This indicates that the meter is perform-
ing a routine self-diagnostic. Do not turn the meter off. Allow the diagnostic procedure to finish. If the
message “C_Er” appears on the display when the meter is turned on, some ranges may be well outside
of specification. To avoid incorrect measurements, stop using the meter and return it to Greenlee for
recalibration.
Operating Procedure
1. Refer to the Settings Table. Set the selector to the proper setting, press SELECT (when instructed to
do so), and connect the test leads to the meter.
2. Refer to “Typical Measurements” for specific measurement instructions.
3. Test the unit on a known functioning circuit or component.
• If the unit does not function as expected on a known functioning circuit, replace the battery and/
or fuses.
• If the unit still does not function as expected, call Greenlee for technical assistance
at 800-435-0786.
4. Take the reading from the circuit or component to be tested.
12
Operation (cont’d)
Settings Table
The meter stores the last used function of each selector position in its nonvolatile memory. If this is not
the correct function when you turn the selector, press SELECT until the desired icon appears.
The dual display options are shown along with the icons. In the table, “~V
Hz
indicates that “~” and “V”
appear in the primary display, and “Hz” appears in the secondary display. This combination shows the
AC voltage measurement in the primary display and frequency in the secondary display.
To measure this
characteristic …
Set the selector to
this symbol…
Press SELECT until
these icons appear on
the display …
Connect
the red
lead to…
Connect the
black lead
to …
Variable Speed Drive—
Voltage and Frequency
V
Hz
or Hz
~V
ΩV
COM
Voltage—AC TrueRMS
(1000 V max)
V
Hz
or Hz
~V
ΩV
COM
*Voltage—DC
(1000 V max)
V or V
~V
ΩV
COM
Voltage—AC + DC
True RMS (1000 V max)
V
~V
ΩV
COM
Voltage—DC
(500 mV max)
mV or mV
~mV
ΩV
COM
Voltage—AC + DC
True RMS (500 mV max)
mV
~mV
ΩV
COM
Voltage—AC
True RMS (500 V max)
mV
Hz
or Hz
~mV
ΩV
COM
Frequency—Line Level
Voltage or Current
Set for voltage or
current according
to this table.
Any display option that
includes Hz
**Frequency—Logic Level
Hz
Hz
ΩV
COM
% Duty Cycle D% D%
ΩV
COM
dBm (0 dB = 1 mW in
reference impedance)
dBm
( function 1000 V
max;
function
500 mV max.)
Reference impedance
and dBm for 1 s, then
dBm
Hz
(press dBm-Ω
to change reference
impedance)
ΩV
COM
* For precise measurements, press 500000 to toggle between 50,000 counts and 500,000 counts.
Applies to DC volts only.
** Logic level frequency has a fixed sensitivity and is for digital signals. Refer to “Accuracy”.
This table continues on the next page.
DM-860A
13
Settings Table (cont’d)
To measure this
characteristic …
Set the selector to
this symbol…
Press SELECT until
these icons appear on
the display …
Connect
the red
lead to…
Connect the
black lead
to …
Dual Temperature T1T2
°C or °F (press RANGE
for display options T1,
T2, T1
T2
or T1-T2
T2
)
See Notes
1 and 2
†Capacitance F
ΩV
COM
Diode V and diod
ΩV
COM
Resistance Ω Ω
ΩV
COM
Continuity
and Ω
ΩV
COM
Conductance nS nS
ΩV
COM
Current—AC, DC, or
AC + DC True RMS
(10 A max)
A
A, A
~A,
A
~A,
or A
Hz
A COM
Current—AC, DC, or
AC + DC True RMS
(600 mA max)
mA
mA
%4-20mA,
mA
~mA,
mA
~mA,
or mA
Hz
mA µA COM
Current—AC, DC, or
AC + DC True RMS
(6000 µA max)
µA
µA, µA
~µA,
µA
~µA,
or µA
Hz
mA µA COM
Industrial Process Control
Loop Current
% 4 to 20 mA
mA
mA
%4-20mA
mA µA COM
Discharge capacitor before measurement. Refer to “Typical Measurements” regarding
polarized capacitors.
Note 1: T1+ connects to ΩV , and T1– connects to COM.
Note 2: T2+ connects to mA µA, and T2– connects to A.
Operation (cont’d)
14
Typical Measurements
Voltage Measurement
Current Measurement
DM-860A
15
Typical Measurements
Continuity Check
Capacitance Measurement Diode Measurement
Resistance Measurement
Reverse Bias
Forward Bias
Note: For polarized capacitors, attach red
probe to positive terminal and black probe
to negative terminal of capacitor.
16
Typical Measurements
Temperature
DM-860A
17
Using the Optional Software
The DM-860A is compatible with Greenlee DMSC-9U, an optically isolated computer interface cable
and software. It allows measurements to be logged to a personal computer using the Microsoft
®
Windows
®
operating system.
Installing the Software
1. Insert the CD into the computer’s CDROM drive.
2. The installation program should launch automatically. If it does not, double click on the CD icon in
“My Computer.”
3. The installation program menu will appear. Click on “Software Installation.”
4. Type your meter’s catalog number (for example, “DM-860A”) in the dialog box.
5. Complete the remaining dialog boxes according to user preferences.
Connecting the Optical USB Interface Cable
1. Align the key of the connector with the key slot on the meter.
2. Twist the connector clockwise until it locks into place.
3. Connect the cable to a USB port of the PC.
Key slot on back of meter
18
Accuracy
Refer to the “Specifications” section for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at 23 °C ± 5 °C
(73.4 °F ± 9 °F), 0% to 75% relative humidity. Specifications are for 50,000 counts mode.
True RMS Readings: Voltage and current accuracies are specified from 5% to 100% of the range
unless otherwise specified. Frequency must be within the specified bandwidth for non-sinusoidal
waveforms. Crest factors are as follows:
• Crest factor < 2.1:1 at full scale
• Crest factor < 4.2:1 at half scale
AC, DC
AC
, and AC + DC
AC
Current
Range
Accuracy at DC
and 50 Hz to 60 Hz
Accuracy at
40 Hz to 1 kHz
Accuracy at
1kHz to 20 kHz
Accuracy at
20 kHz to 100 kHz
500.00 µA ± (0.5% + 0.5 µA) ± (0.7% + 0.5 µA) ± (2.0% + 0.5 µA) ± (5.0% + 0.5 µA)
5000.0 µA ± (0.5% + 5.0 µA) ± (0.7% + 5.0 µA) ± (2.0% + 5.0 µA) ± (5.0% + 5.0 µA)
50.000 mA ± (0.5% + 0.05 mA) ± (0.7% + 0.05 mA) ± (2.0% + 0.05 mA) ± (5.0% + 0.05 mA)
500.00 mA ± (0.5% + 0.5 mA) ± (0.7% + 0.5 mA) ± (2.0% + 0.5 mA) ± (5.0% + 0.5 mA)
5.0000 A ± (0.5% + 0.005 A) ± (0.7% + 0.005 A) Unspecified Unspecified
10.000 A* ± (0.5% + 0.05 A) ± (0.7% + 0.05 A) Unspecified Unspecified
*
10 A continuous; 20 A maximum (Duty Cycle: 30 seconds on, 5 minutes off).
Range
Burden Voltage
(all frequency ranges)
500.00 µA
0.15 mV/µA
5000.0 µA
50.000 mA
3.3 mV/mA
500.00 mA
5.0000 A
45 mV/A
10.000 A
DC Current
Range Accuracy Burden Voltage
500.00 µA ± (0.15% + 0.2 µA)
0.15 mV/µA
5000.0 µA ± (0.1% + 2.0 µA)
50.000 mA ± (0.15% + 0.02 mA)
3.3 mV/mA
500.00 mA ± (0.15% + 0.3 mA)
5.0000 A ± (0.5% + 0.002 A)
45 mV/A
10.000 A* ± (0.5% + 0.02 A)
*
10 A continuous; 20 A maximum (Duty Cycle: 30 seconds on, 5 minutes off).
DM-860A
19
Accuracy (cont’d)
DC
AC
and AC + DC
AC
Voltage
Range
Accuracy* at
20 Hz to 45 Hz
Accuracy* at DC
and 45 Hz to 1 kHz
Accuracy* at
1 kHz to 20 kHz
Accuracy* at
20 kHz to 40 kHz
500.00 mV ± (1.5% + 0.4 mV) ± (0.5% + 0.4 mV) ± (1.0% + 0.4 mV) ± (3.5% + 0.4 mV)**
5.0000 V ± (1.5% + 0.004 V) ± (0.5% + 0.008 V) ± (1.2% + 0.004 V) ± (4.0% + 0.004 V)**
50.000 V ± (1.5% + 0.04 V) ± (0.5% + 0.08 V) ± (1.2% + 0.04 V) ± (4.0% + 0.04 V)**
500.00 V Unspecified ± (0.5% + 0.8 V) Unspecified Unspecified
1000.0 V Unspecified ± (0.5% + 8 V) Unspecified Unspecified
*
From 5% to 10% of range: Accuracy percentage of reading + 80 digits.
**
From 5% to 10% of range: Accuracy percentage of reading + 180 digits.
From 10% to 15% of range: Accuracy percentage of reading + 100 digits.
Residual reading less than 50 digits with test leads shorted.
Note: “Digits” refers to the least significant digit (the number in the right-most position).
VFD AC Voltage
Range
Accuracy* at
5 Hz to 20 Hz
Accuracy* at
20 Hz to 200 Hz
Accuracy* at
200 Hz to 440 Hz
5.0000 V ± (3% + 0.008 V) ± (2% + 0.005 V) ± (6% + 0.008 V)**
50.000 V ± (3% + 0.08 V) ± (2% + 0.05 V) ± (6% + 0.08 V)**
500.00 V ± (3% + 0.8 V) ± (2% + 0.5 V) ± (6% + 0.8 V)**
1000.0 V ± (3% + 8 V) ± (2% + 5 V) ± (6% + 8 V)**
*
Not specified for fundamental frequency greater than 440 Hz.
** Accuracy decreases linearly from ± (2.0% + 50 digits) at 200 Hz to ± (6% + 80 digits) at 440 Hz.
20
Accuracy (cont’d)
AC Voltage
Range
Accuracy* at
20 Hz to 45 Hz
Accuracy* at
45 Hz to 65 Hz
Accuracy* at
65 Hz to 10 kHz
500.00 mV ± (1.2% + 0.4 mV) ± (0.3% + 0.2 mV) ± (0.4% + 0.25 mV)
5.0000 V ± (1.2% + 0.004 V) ± (0.3% + 0.003 V) ± (0.3% + 0.004 V)
50.000 V ± (1.2% + 0.04 V) ± (0.3% + 0.03 V) ± (0.3% + 0.04 V)
500.00 V Unspecified ± (0.5% + 0.3 V) ± (0.5% + 0.4 V)
1000.0 V Unspecified ± (0.5% + 3 V) ± (0.8% + 4 V) (65 Hz to 1 kHz)
Range
Accuracy* at
10 kHz to 20 kHz
Accuracy* at
20 kHz to 100 kHz
500.00 mV ± (0.5% + 0.3 mV) ± (2.5% + 0.4 mV)**
5.0000 V ± (0.7% + 0.004 V) ± (3.5% + 0.004 V)**
50.000 V ± (0.7% + 0.04 V) ± (3.5% + 0.04 V)**
500.00 V ± (0.7% + 0.4 V) Unspecified
1000.0 V Unspecified Unspecified
*
From 5% to 10% of range: Accuracy percentage of reading + 80 digits.
**
From 5% to 10% of range: Accuracy percentage of reading + 180 digits.
Residual reading less than 50 digits with test leads shorted.
Note: “Digits” refers to the least significant digit (the number in the right-most position).
DC Voltage
Range Accuracy Input Impedance
500.00 mV ± (0.02% + 0.02 mV) 10 MΩ, 80 pF nominal
5.0000 V ± (0.02% + 0.0002 V)
10 MΩ, 60 pF nominal
50.000 V ± (0.03% + 0.002 V)
500.00 V ± (0.04% + 0.02 V)
1000.0 V ± (0.15% + 0.2 V)
DM-860A
21
Accuracy (cont’d)
Resistance and Conductance
Range Accuracy
Typical Open Circuit
Voltage
500.00 Ω ± (0.07% + 0.10 Ω) 3.0 VDC
5.0000 kΩ ± (0.07% + 0.0002 kΩ)
1.3 VDC
50.000 kΩ ± (0.1% + 0.002 kΩ)
500.00 kΩ ± (0.1% + 0.02 kΩ)
5.0000 MΩ ± (0.3% + 0.0006 MΩ)
50.000 MΩ ± (2.0% + 0.006 MΩ)
99.99 nS ± (0.8% + 0.10 nS)*
*
± (2.0% + 0.40 nS) below 9.99 nS.
Capacitance
Range Accuracy*
*
Accuracies are for film capacitors
(capacitors with negligible dielectric absorption).
**
In manual ranging mode, the 500.0 µF, 5.000 mF, and
25.00 mF ranges are not specified below 45.0 µF,
0.450mF, and 4.50 mF, respectively.
50.00 nF ± (0.8% + 0.03 nF)
500.0 nF ± (0.8% + 0.3 nF)
5.000 µF ± (1.5% + 0.003 µF)
50.00 µF ± (2.5% + 0.03 µF)
500.0 µF** ± (3.5% + 0.5 µF)
5.000 mF** ± (5.0% + 0.005 mF)
25.00 mF** ± (6.5% + 0.05 mF)
T1, T2, T1-T2 Dual Temperature
Range Accuracy*
–50 °C to 1000.0 °C ± (0.3% + 1.5 °C)
–58 °F to 1832.0 °F ± (0.3% + 3.0 °F)
*
Thermocouple range and accuracy
not included.
22
Accuracy (cont’d)
Frequency—Line Level
Range: 5.000 Hz to 200.00 kHz
Accuracy: ± (0.02% + 4 digits)
AC Function
Range
Sensitivity
(Sine RMS)
Range
AC Function
Range
Sensitivity
(Sine RMS)
Range
500 mV 100 mV
10 Hz to 200 kHz
500 µA 50 µA
10 Hz to 10 kHz
5 V 0.5 V 5000 µA 500 µA
50 V 5 V
10 Hz to 100 kHz
50 mA 5 mA
500 V 50 V 500 mA 50 mA
1000 V 500 V 10 Hz to 10 kHz 5 A 1 A
10 Hz to 3 kHz
VFD 5 V 0.5 V to 2 V*
10 Hz to 440 Hz
10 A 10 A
VFD 50 V 5 V to 20 V*
*
VFD sensitivity linearly decreases from 10% of
range @ 200 Hz to 40% of range @ 440 Hz.
VFD 500 V 50 V to 200 V*
Frequency —Logic Level
Range: 5.000 Hz to 2.0000 MHz
Accuracy: ± (0.002% + 4 digits)
Sensitivity: 2.5 Vp square wave
% Duty Cycle
Range: 0.1% to 99.99%
Accuracy: ± (3 digits/kHz + 2 digits)
Input Frequency: 5 Hz to 500 kHz, 5 V logic family
Diode Test
Measuring Range: 2.0000 V
Test Current (typical): 0.4 mA
Open Circuit Voltage: < 3.0 VDC
Accuracy: ± (1% + 0.0001 V)
Continuity
Tone Threshold: Between 20 Ω and 200 Ω
Response Time: < 100 µs
dBm
The range and accuracy depend on the AC voltage function used and the selected reference
impedance.
Selectable Reference Impedance: 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500,
600, 800, 900, 1000, 1200 Ω
Crest Capture (Voltage and Current) for Crests > 0.8 ms in duration
Accuracy: Specified accuracy ± 100 digits
Resolution: 5000 digits
DM-860A
23
Specifications
Display: LCD
Normal Mode: 50,000 counts
High Resolution Mode: 500,000 counts
Frequency: 99,999 counts
41-segment bar graph
Polarity: Automatic
Input Impedance: 10 MΩ, 60 pF nominal (80 pF for 500 mV ranges).
Sampling Rate:
50,000 Counts Mode: 5 per second nominal
500,000 Counts Mode: 1.25 per second nominal
Bar Graph Display: 60 per second
Temperature Coefficient: Nominal 0.15 x (Accuracy) per °C below 18 °C from 0 °C to 18 °C
(32 °F to 64 °F) or above 28 °C from 28 °C to 40 °C (82 °F to 104 °F) or otherwise specified
Intelligent Automatic Power Off: After 17 minutes of inactivity
Low Battery Indication: Below approximately 7 V
Noise Rejection*:
Normal Mode Rejection Ratio > 60 dB at 50 Hz and 60 Hz when measuring DCV
Common Mode Rejection Ratio > 90 dB from 0 Hz to 60 Hz when measuring ACV
Common Mode Rejection Ratio > 120 dB at 50 Hz and 60 Hz when measuring DCV
Operating Conditions:
0 °C to 31 °C (32 °F to 88 °F), 0% to 80% relative humidity
31 °C to 45 °C (88 °F to 113 °F), relative humidity decreasing linearly from 80% to 50%
(non-condensing)
Altitude: 2000 m (6500') maximum
Indoor use only
Pollution Degree: 2
Storage Conditions: –20 °C to 60 °C (–4 °F to 140 °F), 0% to 80% relative humidity (non-condensing)
Remove battery
Battery: 9 V battery (NEDA 1604, JIS 006P or IEC 6F)
E.M.C.: Meets EN61326-1:2006
In an RF field of 3 V/m:
Capacitance function is not specified
Other function ranges: Total Accuracy = Specified Accuracy + 1000 digits
Performance above 3 V/m is not specified
* Noise rejection is the ability to reject unwanted signals, or noise.
• Normal mode voltages are AC signals that can cause inaccurate DC measurements. NMRR
(Normal Mode Rejection Ratio) is a measure of the ability to filter out these signals.
• Common mode voltages are signals present at the COM and + input terminals, with respect to
ground, that can cause digit rattle or offset in voltage measurements. CMRR (Common Mode
Rejection Ratio) is a measure of the ability to filter out these signals.
24
Specifications (cont’d)
Safety: Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-
033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to Category
IV 1000 V AC/DC.
Overload Protections:
V: 1100 V DC/AC rms
A: 11 A/1000 V fuse, interrupting rating 20 kA, F fuse, 13/32" x 1-1/2"
µA and mA: 0.44 A/1000 V fuse, interrupting rating 10 kA, F fuse, 13/32" x 1-3/8"
mV, Ω, and Other Functions: 1000 V DC/AC rms
CENELEC DIRECTIVES: The instruments conform to CENELEC Low-voltage directive 2006/95/EC and
Electromagnetic compatibility directive 2004/108/EC
Measurement Categories
These definitions were derived from the international safety standard for insulation coordination as
it applies to measurement, control, and laboratory equipment. These measurement categories are
explained in more detail by the International Electrotechnical Commission; refer to either of their
publications: IEC 61010-1 or IEC 60664.
Measurement Category I
Signal level. Electronic and telecommunication equipment, or parts thereof. Some examples include
transient-protected electronic circuits inside photocopiers and modems.
Measurement Category II
Local level. Appliances, portable equipment, and the circuits they are plugged into. Some examples
include light fixtures, televisions, and long branch circuits.
Measurement Category III
Distribution level. Permanently installed machines and the circuits they are hard-wired to. Some exam-
ples include conveyor systems and the main circuit breaker panels of a building’s electrical system.
Measurement Category IV
Primary supply level. Overhead lines and other cable systems. Some examples include cables, meters,
transformers, and other exterior equipment owned by the power utility.
Statement of Conformity
Greenlee Tools, Inc. is certified in accordance with ISO 9001:2008 for our Quality Management
Systems.
The instrument enclosed has been checked and/or calibrated using equipment that is traceable to the
National Institute for Standards and Technology (NIST).
DM-860A
25
Maintenance
Electric shock hazard:
Before opening the case, remove the test leads from the circuit and shut off the unit.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
The fuses are an integral part of the overvoltage protection. When fuse replacement is necessary,
refer to “Specifications” for the correct type, size, and capacity. Using any other type of fuse will void
the overvoltage protection rating of the unit.
Failure to observe this warning could result in severe injury or death.
Replacing the Battery
1. Disconnect the unit from the circuit. Turn the unit OFF.
2. Remove the two screws from the battery access door
and remove it.
3. Replace the battery making sure to observe the polarity.
Replacing the Fuses
1. Disconnect the unit from the circuit. Turn the unit OFF.
2. Remove the two screws from the battery access door
and remove it.
3. Unscrew the two screws inside the battery compartment
and the two screws on the back case.
4. Remove the back cover and replace the fuses.
5. Align the two halves of the unit and the rubber gaskets.
6. Be sure the selector is in the original position so that it lines up properly with the internal switch.
7. Replace the cover and screws.
Cleaning and Storage
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives
or solvents.
If the meter will not to be used for periods longer than 60 days, remove the battery and store it
separately.
26
DM-860A
27
Descripción
El multímetro digital DM-860A de Greenlee es un dispositivo manual de pruebas que posee las
siguientes capacidades de medición: Voltaje de CA y CC, corriente de CA y CC, porcentaje de corriente
de bucle, dos canales de temperatura (termopares tipo K), frecuencia, ciclo de trabajo, resistencia,
conductancia y capacitancia.
También sirve para verificar diodos y continuidad.La unidad DM-860A cuenta con una pantalla de
gráfico de barras, que responde más rápidamente que la pantalla numérica — útil para detectar fallas
en contactos, potenciómetros y picos de señal. Una interfaz opcional de ordenador ópticamente aislada
y software facilitan la grabación de lecturas del medidor a un ordenador.
Otras de sus funciones y capacidades incluyen:
• Pantalla doble que muestra simultáneamente dos mediciones, como el voltaje de CA y la frecuencia.
• La función Beep-Jack™ que le advierte al usuario, mediante un tono audible y un mensaje de error
en la pantalla LCD, si el cable de prueba se encuentra conectado a una terminal de entrada
mA µA o A mientras el interruptor de selección no se encuentra en la posición mA µA o A.
• Ancho de banda de CA a 100 kHz para voltaje o 20 kHz para corriente.
• Función “MAX/MIN”, la cual guarda la señal máxima, mínima y la promedio.
• Modo de captura de valor de cresta para capturar picos de señal de voltaje o corriente.
• Seleccionable entre resolución de 50.000 ó 500.000 puntos al medir voltaje de corriente continua.
• Modo de cero relativo.
• Selección de escala manual o automática.
• Apagado automático inteligente.
• Pantalla de LCD con luz de fondo que facilita la lectura en condiciones de iluminación tenue.
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las herramientas y equipo
Greenlee. Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la
información necesaria para evitar riesgos y hábitos poco seguros relacionados con su uso. Siga toda la
información sobre seguridad que se proporciona.
Propósito de este manual
Este manual de instrucciones tiene como propósito familiarizar a todo el personal con los
procedimientos de operación y mantenimiento seguros para el Multímetro digital modelo DM-860A de
Greenlee.
Manténgalo siempre al alcance de todo el personal. Puede obtener copias adicionales de manera
gratuita, previa solicitud en www.greenlee.com.
¡No deseche ni descarte este producto!
Para información sobre reciclaje, visite www.greenlee.com.
28
SÍMBOLO DE ALERTA
SOBRE SEGURIDAD
Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría ocasionar
lesiones o daños materiales. Cada uno de los siguientes términos denota la gravedad del riesgo.
El mensaje que sigue a dichos términos le indica cómo puede evitar o prevenir ese riesgo.
Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso la muerte.
Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la muerte.
Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o daños
materiales.
Lea y entienda este documento antes de manejar esta herramienta o darle
mantenimiento. Utilizarla sin comprender cómo manejarla de manera segura
podría ocasionar un accidente, y como resultado de éste, graves lesiones o
incluso la muerte.
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar graves lesiones o incluso la
muerte.
Importante Información sobre Seguridad
Todas las especificaciones son nominales y pueden cambiar conforme tengan lugar mejoras de diseño. Greenlee
Tools, Inc. no se hace responsable de los daños que puedan surgir de la mala aplicación o mal uso de sus productos.
® Registrado: El color verde para instrumentos de verificación eléctricos es una marca registrada
de Greenlee Tools, Inc.
Beep-Jack es una marca comercial de BTC.
Microsoft y Windows son marcas comerciales registradas de Microsoft Corporation.
CONSERVE ESTE MANUAL
DM-860A
29
Importante Información sobre Seguridad
Peligro de electrocución e incendio:
• No exponga esta unidad ni a la lluvia ni a la humedad.
• No utilice esta unidad si se encuentra mojada o dañada.
• Utilice solo los conductores de prueba proporcionados con el equipo o un conjunto de sonda con
certificación UL con una calificación igual o superior.
• Revise minuciosamente los cables de prueba o el accesorio, antes de utilizarlos. Deberán estar
limpios y secos, y su forro aislante deberá hallarse en buenas condiciones. No utilice el conductor
de prueba si la capa interna de aislamiento en contraste resulta visible.
• Utilícela únicamente para el propósito para el que ha sido diseñada por el fabricante,
tal como se describe en este manual. Cualquier otro uso puede menoscabar la protección
proporcionada por la unidad.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución:
• No aplique más del voltaje nominal entre dos terminales de entrada cualesquiera, o entre una
terminal de entrada cualquiera y una conexión a tierra.
• No toque las puntas de los cables de prueba ni ninguna parte del accesorio que carezca de forro
aislante.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución:
• No haga funcionar esta unidad con la caja abierta.
• Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución:
Los fusibles son una parte integral para la protección contra sobretensión. Cuando sea necesario
reemplazarlos, consulte la sección “Especificaciones” para saber qué tipo, tamaño y capacidad
deben tener. Utilizar cualquier otro tipo de fusible anulará la clasificación de protección de
sobretensión de la unidad.
De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte.
30
Importante Información sobre Seguridad
Peligro de electrocución:
• A menos que vaya a medir tensión, corriente o frecuencia, apague y bloquee la energía. Asegúrese
de que todos los condensadores estén totalmente sin carga. No debe haber tensión alguna.
• Coloque el interruptor de selección y conecte los cables de prueba de modo que correspondan
al tipo de medición que se desea efectuar. Si se colocan o se conectan incorrectamente puede
quemarse un fusible.
• Al utilizar esta unidad cerca de equipo que genere interferencia electromagnética quizá se obtenga
una lectura inexacta e inestable.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución:
No cambie la función de medición mientras los cables de prueba estén conectados a un componente
o circuito.
De no observarse esta precaución podrían sufrirse lesiones o daños a la unidad.
Peligro de electrocución:
• No intente reparar esta unidad, ya que contiene partes que deben recibir mantenimiento por parte
de un profesional.
• No exponga la unidad a ambientes de temperatura extrema o altos niveles de humedad. Consulte
las Especificaciones.
De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad.
DM-860A
31
Identificación
1. Pantalla de cristal líquido (LCD) y gráfico de barras
2. Botones Consulte la explicación pertinente en la sección
de funciones “Cómo utilizar las distintas funciones”
3. Interruptor Selecciona una función o apaga (OFF) la unidad
de selección
4. A Terminal de entrada positiva para mediciones de corriente alta;
terminal de entrada negativa para T2
5. mA µA Terminal de entrada positiva para mediciones de corriente baja;
terminal de entrada positiva para T2
6. COM Terminal de entrada a tierra, común o negativo, para todo tipo de mediciones
7. ΩV Terminal de entrada positiva para todo tipo de mediciones excepto corriente
1
3
2
4 7
5 6
Símbolos en la unidad
Advertencia — Lea el manual de instrucciones
Doble forro aislante
32
Pantalla principal
8.
Elemento de gráfico de barras
9. Indicador de polaridad para
el gráfico de barras
10. Escala del gráfico de barras
11. Está activa la función de Cero relativo.
12. VFD Está activa la función VFD.
13. Indicador de polaridad
14. 8.8.8.8.88 Pantalla numérica
15. T1-T2 Está activa la función T1, T2 o T1-T2.
16. Está seleccionada la medición de CA.
17. Está seleccionada la medición de CC.
18. MAX Valor máximo que se está grabando
o mostrando.
19. MIN Valor mínimo que se está grabando
o mostrando.
20. AVG Valor promedio que se está grabando
o mostrando.
21. Está activa la función Record (Grabar).
22. Está activa la función “Crest Capture”
(Captura de valor de cresta).
23. Está activa la función “Hold”
(retención de datos en pantalla).
24. Está activa la selección automática
de escala.
25. Continuidad
26. Pila baja
27. } Símbolo de sobrecarga
(pantalla de gráfico de barras)
28. 5 Indicador de alcance máximo
en gráfico de barras
29. D% Está activa la función
de ciclo
de operación.
30. k Kilo (10
3
)
31. M Mega (10
6
)
32. Ω Ohmios
33. Hz Hertzios (frecuencia en
ciclos por segundo)
34. dBm Decibel
35. m Mili (10
-3
)
36. µ Micro (10
-6
)
37. V Voltio
38. A Amperio
39. n Nano (10
-9
)
40. F Faradio
41. S Siemen
Pantalla secundaria
42. %4-20mA Se activa la función de corriente
de bucle de control del
proceso industrial.
43. µ Micro (10
-6
)
44. m Mili (10
-3
)
45. A Amperio
46. V Voltio
47. M Mega (10
6
)
48. k Kilo (10
3
)
49. Hz Hertzios (frecuencia en
ciclos por segundo)
50. 8.8.8.8 Pantalla numérica
51. T2 Está activa la función T2.
52. Está seleccionada la medición
de CA.
53. Indicador de polaridad
Iconos de la pantalla
24
21-23
18-20
16-17
15
12
11
10
8-9
13-14
47-49
43-46
42
29-41
27
28
2625
51-53
50
DM-860A
33
Pantalla digital doble: Este medidor puede mostrar simultáneamente dos mediciones, como el
voltaje de CA y la frecuencia. Las combinaciones de imagen en pantalla se muestran con símbolos
grandes para indicar la medición en la pantalla primaria, y con símbolos pequeños y elevados para
indicar la medición en la pantalla secundaria. Por ejemplo, “VAC
Hz
significa que la pantalla primaria
contiene la medición de voltaje de CA, y la pantalla secundaria contiene la medición de frecuencia.
VFD ~V y VFD Hz: Estas funciones utilizan filtros y algoritmos de rechazo de ruido para efectuar
mediciones exactas de voltaje y frecuencia en la mayoría de motores de frecuencia variable. La
medición de voltaje selecciona automáticamente la escala de 500 V. Use el botón RANGE para
seleccionar otras escalas solamente cuando sea necesario. La sensibilidad para mediciones de
frecuencia VFD depende de la escala de voltaje y de la frecuencia de entrada. Consulte “Frecuencia –
Nivel de línea” en la sección “Exactitud” de este manual.
SELECT (Seleccionar): Oprímalo momentáneamente para alternar entre las funciones, modos de
medición o modos de pantalla. El último ajuste utilizado se convierte en el valor por defecto cuando
se vuelva a seleccionar dicha función. Para cambiar el valor por defecto, seleccione un nuevo ajuste.
El ajuste será almacenado en una memoria estable.
RANGE (Escala): Oprímalo una vez para ingresar al modo de selección manual de escala. El icono
desaparecerá de la pantalla. Oprímalo repetidamente para pasar de una escala a otra.
Manténgalo oprimido para volver al modo de selección automática de escala.
Aviso: Cuando se estén utilizando los modos CREST, REC, HOLD, o ∆, si se oprime el botón RANGE el
medidor saldrá del modo en que se encuentre.
∆: Le muestra la diferencia entre dos mediciones. Mientras efectúa una medición, oprima para
poner la pantalla en ceros. Enseguida aparecerá el icono en la pantalla. Efectúe la segunda
medición. El valor que aparezca en la pantalla equivaldrá a la diferencia entre ambas mediciones.
Oprímalo nuevamente para salir de este modo.
Esta característica se aplica solamente a la pantalla principal.
HOLD : Oprímalo momentáneamente para retener en pantalla el valor que aparece en ese
momento. Oprímalo nuevamente para salir de este modo.
Esta función no afecta al gráfico de barras.
CREST : Oprima momentáneamente este botón para activar el modo de grabación de cresta.
En este modo, el valor de entrada se mide cada 1 milisegundos. y “MAX” aparecerán en la
pantalla. En la pantalla LCD aparecerá el valor de cresta máximo. El medidor emitirá un tono siempre
que se actualice el valor máximo o mínimo. Oprímalo repetidamente para seleccionar la pantalla
deseada: máximo o mínimo valor de cresta. Mantenga oprimido el botón para salir de este modo.
La función de apagado automático se desactiva al utilizar esta función.
Aviso: Cuando se esté utilizando la función CREST, si se oprime el botón RANGE el medidor saldrá
del modo en que se encuentre.
• REC : Oprima momentáneamente este botón para activar el modo de grabación MAX/MIN/AVG.
En este modo, el valor de entrada se mide cada 50 milisegundos. Enseguida aparecerán “MAX/MIN”
y “AVG” en la pantalla. En la pantalla LCD aparecerá el valor del dato actual. El medidor emitirá un
tono siempre que se actualice el valor máximo o mínimo. Oprímalo repetidamente para seleccionar
la pantalla deseada: máximo, mínimo, promedio o dato real. Mantenga oprimido el botón para salir
de este modo.
Cómo utilizar las distintas funciones
34
Cómo utilizar las distintas funciones (continuación)
La función de apagado automático se desactiva al utilizar esta función.
Aviso: Cuando se esté utilizando la función REC, si se oprime el botón RANGE el medidor saldrá del
modo en que se encuentre.
: Manténgalo oprimido hasta que se ilumine la luz de fondo. Oprímalo nuevamente sin
soltar para apagarla. La luz de fondo se apagará automáticamente después de aproximadamente
30segundos a fin de preservar la vida útil de la pila.
dBm-Ω: La impedancia de referencia aparece durante un segundo después de seleccionar la
función dBm. Oprima momentáneamente dBm-Ω para cambiar la impedancia de referencia. Consulte
en la sección “Especificaciones” los valores disponibles.
Aviso: Ésta es una medición de voltaje de CA calculada según la fórmula
dBm = 20 x log (voltaje medido / voltaje de referencia
El voltaje de referencia es aquel que causa que 1 mW de potencia se disipe en la impedancia de
referencia seleccionada.
T1-T2: Oprima momentáneamente este botón para seleccionar la pantalla de temperatura
deseada: T1, T2, T1
T2
o T1-T2
T2
.
500000: Oprima sin soltar el conmutador para alternar entre el modo rápido de 50.000 puntos y el
modo de alta resolución de 500.000 puntos para mediciones de frecuencia y voltaje de CC.
Apagado automático inteligente (APO): A fin de prolongar la vida útil de la pila, el medidor se
apaga por sí solo después de 17 minutos de inactividad. La inactividad ocurre cuando no se oprimen
los botones o no se gira el interruptor de selección. El medidor no realizará la función de apagado
automático inteligente (APO) cuando hayan lecturas importantes de más de 10% de la escala o
lecturas para resistencia y continuidad que no sean indicativas de sobrecarga. Para restaurar la
energía, oprima SELECT, RANGE, , o HOLD o bien, gire el interruptor de selección hacia OFF y
vuelva a encender la unidad. Para desactivar esta función, oprima SELECT (Seleccionar) al tiempo
que enciende la unidad.
Cómo desactivar la función de tono audible: Mantenga oprimido el botón RANGE a la vez que
enciende el medidor a fin de desactivar temporalmente la función de tono audible. Para activar el
tono audible, gire el selector a la posición OFF y después vuelva a encenderlo.
Hz: Se puede medir la frecuencia en la mayoría de ajustes de voltaje y corriente del selector.
Oprima SELECT hasta que aparezca “Hz” en la pantalla primaria o secundaria, según se desee.
La sensibilidad de la función Frecuencia a nivel de línea varía con la escala de medición. Consulte
la sección “Especificaciones”. Las mediciones con escala autoajustable usualmente establecen el
mejor nivel de disparador. Si la lectura de frecuencia se vuelve inestable o queda en blanco, oprima
el botón RANGE para seleccionar otro nivel de disparador.
%4-20 mA: Este valor calculado es una de tres opciones disponibles para la pantalla secundaria al
medir miliamperios de CC. Esto es útil para aplicaciones de bucle de control de procesos industriales
de 4-20 mA. Una lectura de 4 mA en la pantalla principal produce una lectura de 0% en la pantalla
secundaria, 12 mA producen 50%, 20 mA producen 100%, etc.
DM-860A
35
Medición de corriente alterna
Las mediciones de corriente alterna generalmente se muestran como valores eficaces (RMS o root
mean squared). El valor eficaz equivale al valor de una forma de onda de CC, la cual brinda la misma
potencia que si reemplazara la forma de onda variable con el tiempo. Existen dos métodos de medición
de corriente alterna: calibrados para responder al valor eficaz medio y a una lectura de valores eficaces
reales.
El método calibrado para responder al valor eficaz medio toma el valor medio de la señal de entrada
luego de una rectificación total de onda, la multiplica por 1,11 y muestra el resultado. El resultado es
exacto si la señal de entrada es una onda sinusoidal pura.
El método de lectura de valores eficaces reales utiliza un circuito interno para leer el valor
eficaz real. Este método es exacto, dentro de las limitaciones de factor de cresta especificadas,
independientemente del tipo de señal de entrada, ya sea una onda sinusoidal pura, rectangular,
triangular, media onda o señal con armónicas. La capacidad para leer valores eficaces reales brinda
una mayor versatilidad de medición. La unidad DM-860A de Greenlee es un medidor de valores
eficaces (RMS) reales.
La tabla de Formas de onda y Factores de cresta muestra algunas de las señales de CA y sus valores
eficaces reales más comunes.
Formas de onda y Factores de cresta
Forma de onda
Valor eficaz 100 100 100 100
Valor medio 90 100 87 64
Factor de
cresta* (x)
1,414 1 1,73 2
* El factor de cresta es el cociente de un valor máximo en relación con el valor eficaz; está
representado por la letra griega x.
Valor eficaz real CA + CC
El valor eficaz real CA + CC calcula los componentes de CA y CC expresados
al efectuar mediciones y responde acertadamente al valor eficaz efectivo total independientemente de
la forma de onda. Formas de onda distorsionadas con la presencia de componentes de CC y armónicas
podrían ocasionar:
• el sobrecalentamiento de transformadores, generadores y motores
• el disparo prematuro de interruptores automáticos de circuito
• que fusibles se quemen
• el sobrecalentamiento de neutrales debido a la presencia de armónicas triples en el neutral
• la vibración de barras colectoras y paneles eléctricos
36
Ancho de banda de CA
El ancho de banda de CA de un multímetro digital (DMM) es la gama de frecuencias sobre la cual se
pueden efectuar mediciones de CA dentro de una precisión específica. Se trata de la respuesta de
frecuencia de las funciones de CA—no de las funciones de medición de frecuencia. Un DMM no puede
efectuar mediciones precisas de valores de CA con espectros de frecuencia que excedan el ancho
de banda de CA. Por lo tanto, un ancho de banda de CA amplio desempeña un papel fundamental en
multímetros digitales de alto rendimiento. Las formas de onda complejas, el ruido y las formas de onda
distorsionadas contienen componentes de frecuencia mucho mayores que los fundamentales; por
ejemplo, ruido de alta frecuencia en una línea de energía de 50/60 Hz.
Operación
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar graves lesiones o incluso la
muerte.
Modo de autodiagnóstico
El mensaje “rE-O” puede aparecer cuando se enciende el medidor. Esto indica que el medidor está
realizando un autodiagnóstico de rutina. No apague el medidor. Deje que termine el procedimiento
de diagnóstico. Si aparece el mensaje “C_Er” en la pantalla al encender el medidor, algunas escalas
pueden estar sustancialmente fuera de especificación. Para evitar mediciones erróneas, suspenda el
uso del medidor y devuélvalo a Greenlee para su recalibración.
Procedimiento de operación
1. Consulte la Tabla de ajustes. Coloque el interruptor de selección en el ajuste apropiado, oprima
SELECT (cuando se le pida que lo haga), y conecte los cables de prueba al multímetro.
2. Consulte la sección “Mediciones más comunes” en relación con las instrucciones específicas para
cada tipo de medición.
3. Pruebe la unidad en un circuito o componente que se sabe está funcionando perfectamente.
• Si la unidad no funciona como debería en un circuito que se sabe está funcionando
perfectamente, reemplace la pila y/o los fusibles.
• Si la unidad aún sigue sin funcionar como debería, llame a Greenlee al 800-435-0786 para
obtener asistencia técnica.
4. Anote la lectura del circuito o componente que se está verificando.
DM-860A
37
Operación (continuación)
Tabla de ajustes
El medidor almacena la última función utilizada de cada una de las posiciones del interruptor de
selección en su memoria no volátil. Si ésta no resulta ser la función correcta al girar el interruptor de
selección, oprima SELECT hasta que aparezca el icono deseado.
Las opciones de pantalla doble se muestran junto con los iconos. En la tabla, “~V
Hz
indica que “~”
y “V” aparecen en la pantalla principal, y “Hz” aparece en la pantalla secundaria. Esta combinación
muestra la medición de voltaje de CA en la pantalla primaria y la frecuencia en la pantalla secundaria.
Para medir
esta función …
Coloque el
interruptor de
selección en este
símbolo…
Oprima SELECT hasta
que estos iconos
aparezcan en la
pantalla …
Conecte
el cable
de prueba
rojo a…
Conecte
el cable
de prueba
negro a …
Motor de velocidad
variable—Voltaje y
frecuencia
V
Hz
o Hz
~V
ΩV
COM
Voltaje—CA RMS real
(1000 V máx.)
V
Hz
o Hz
~V
ΩV
COM
*Voltaje—CC
(1000 V máx.)
V o V
~V
ΩV
COM
Voltaje—CA + CC RMS
real (1000 V máx.)
V
~V
ΩV
COM
Voltaje—CC
(500 mV máx.)
mV o mV
~mV
ΩV
COM
Voltaje—CA + CC RMS
real (500 mV máx.)
mV
~mV
ΩV
COM
Voltaje—CA RMS
real (500 V máx.)
mV
Hz
o Hz
~mV
ΩV
COM
Frecuencia—Nivel de línea
de voltaje o de corriente
Colocar en voltaje
o corriente según
esta tabla.
Cualquier opción de
pantalla que incluya Hz
**Frecuencia—Nivel lógico
Hz
Hz
ΩV
COM
% Ciclo de trabajo D% D%
ΩV
COM
dBm (0 dB = 1 mW en
impedancia de referencia)
dBm
(función 1000 V
máx; función
500 mV máx.)
Impedancia de referencia
y dBm durante 1 s,
después dBm
Hz
(oprima
dBm-Ω para cambiar la
impedancia de referencia)
ΩV
COM
* Para mediciones exactas, oprima 500000 a fin de alternar entre 50.000 puntos y 500.000 puntos.
Se aplica solamente a voltajes de CC.
** El nivel de frecuencia lógico tiene una sensibilidad fija
y se aplica a señales digitales. Consulte “Exactitud”.
La Tabla continúa en la siguiente página.
38
Tabla de ajustes (continuación)
Para medir
esta función …
Coloque el
interruptor de
selección en este
símbolo…
Oprima SELECT hasta
que estos iconos
aparezcan en la
pantalla …
Conecte
el cable
de prueba
rojo a…
Conecte
el cable
de prueba
negro a …
Temperatura doble T1T2
°C o °F (oprima RANGE
para las opciones de
pantalla T1, T2, T1
T2
o
T1-T2
T2
)
Ver las
Notas 1 y 2
†Capacitancia F
ΩV
COM
Diodo V y diod
ΩV
COM
Resistencia Ω Ω
ΩV
COM
Continuidad
y Ω
ΩV
COM
Conductancia nS nS
ΩV
COM
Corriente—CA, CC, o
CA + CC RMS real
(10 A máx.)
A
A, A
~A,
A
~A,
o A
Hz
A COM
Corriente—CA, CC, o
CA + CC RMS real
(600 mA máx.)
mA
mA
%4-20mA,
mA
~mA,
mA
~mA,
o mA
Hz
mA µA COM
Corriente—CA, CC, o
CA + CC RMS real
(6000 µA máx.)
µA
µA, µA
~µA,
µA
~µA,
o µA
Hz
mA µA COM
Corriente de bucle de
control de proceso
industrial
% 4 a 20 mA
mA
mA
%4-20mA
mA µA COM
Descargue el capacitor antes de efectuar una medición. Consulte “Mediciones más comunes”
respecto a los capacitores polarizados.
Nota 1: T1+ se conecta a ΩV , y T1– se conecta a COM.
Nota 2: T2+ se conecta a mA µA, y T2– se conecta a A.
Operación (continuación)
DM-860A
39
Mediciones más comunes
Medición de voltaje
Medición de corriente
40
Mediciones más comunes
Verificación de continuidad
Medición de capacitancia Verificación de diodo
Medición de resistencia
Polarización
inversa
Polarización
directa
Aviso: Para condensadores polarizados, conecte
la sonda roja al terminal positivo y la sonda negra
al terminal negativo del condensador.
DM-860A
41
Mediciones más comunes
Temperatura
42
Cómo utilizar el software opcional
La unidad DM-860A es compatible con Greenlee DMSC-9U, un cable y software de interfaz
ópticamente aislada de ordenador. Permite grabar mediciones en un ordenador personal utilizando el
sistema operativo Microsoft
®
Windows
®
.
Cómo instalar el software
1. Introduzca el CD en la unidad CDROM del ordenador.
2. El programa de instalación se iniciará automáticamente. Si no ocurre así, haga doble clic en el
icono de CD en “Mi PC”.
3. Aparecerá el menú del programa de instalación. Haga clic en “Software Installation”
(Instalación del software).
4. Escriba el número de catálogo de su medidor (por ejemplo, “DM-860A”) en el cuadro de diálogo.
5. Complete los cuadros de diálogo restantes según las preferencias del usuario.
Cómo conectar el cable de interfaz USB óptico
1. Alinee la ranura en el conector con la ranura en el medidor.
2. Gire el conector en el sentido de las manillas del reloj hasta que caiga en su posición.
3. Conecte el cable a un puerto USB de la PC..
Ranura en la parte posterior del medidor
DM-860A
43
Exactitud
Consulte la sección “Especificaciones” en relación con las condiciones de operación y el coeficiente de
temperatura.
La exactitud se especifica de la siguiente manera: ± (un porcentaje de la lectura + una cantidad fija)
a 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% a 75% de humedad relativa. Las especificaciones se refieren al
modo de 50.000 puntos.
Lecturas de valores RMS (eficaces) reales: Las precisiones de voltaje y corriente se especifican a partir
del 5% hasta el 100% de la escala a menos que se indique algo diferente. La frecuencia debe hallarse
dentro del ancho de banda especificado para formas de onda no sinusoidales. Los factores de cresta
son los siguientes:
• Factor de cresta < 2,1:1 a plena escala
• Factor de cresta < 4,2:1 a escala media
Corriente de CA, CC
CA
, y CA + CC
CA
Escala
Exactitud en CC
y 50 Hz a 60 Hz
Exactitud a
40 Hz hasta 1 Hz
Exactitud a 1 kHz
hasta 20 kHz
Exactitud a 20 kHz
hasta 100 kHz
500,00 µA ± (0,5% + 0,5 µA) ± (0,7% + 0,5 µA) ± (2,0% + 0,5 µA) ± (5,0% + 0,5 µA)
5000,0 µA ± (0,5% + 5,0 µA) ± (0,7% + 5,0 µA) ± (2,0% + 5,0 µA) ± (5,0% + 5,0 µA)
50,000 mA ± (0,5% + 0,05 mA) ± (0,7% + 0,05 mA) ± (2,0% + 0,05 mA) ± (5,0% + 0,05 mA)
500,00 mA ± (0,5% + 0,5 mA) ± (0,7% + 0,5 mA) ± (2,0% + 0,5 mA) ± (5,0% + 0,5 mA)
5,0000 A ± (0,5% + 0,005 A) ± (0,7% + 0,005 A) No especificada No especificada
10,000 A* ± (0,5% + 0,05 A) ± (0,7% + 0,05 A) No especificada No especificada
*
10 A continuos; 20 A máximo (Régimen de trabajo: 30 segundos encendido, 5 minutos apagado).
Escala Voltajes de carga (todas las escalas de frecuencia)
500,00 µA
0,15 mV/µA
5000,0 µA
50,000 mA
3,3 mV/mA
500,00 mA
5,0000 A
45 mV/A
10,000 A
Corriente continua (CC)
Escala Exactitud Voltajes de carga
500,00 µA ± (0,15% + 0,2 µA)
0,15 mV/µA
5000,0 µA ± (0,1% + 2,0 µA)
50,000 mA ± (0,15% + 0,02 mA)
3,3 mV/mA
500,00 mA ± (0,15% + 0,3 mA)
5,0000 A ± (0,5% + 0,002 A)
45 mV/A
10,000 A* ± (0,5% + 0,02 A)
*
10 A continuos; 20 A máximo (Régimen de trabajo: 30 segundos encendido, 5 minutos apagado).
Corriente de CA, CC
CA
, y CA + CC
CA
44
Exactitud (continuación)
Voltaje de CC
CA
y CA + CC
CA
Escala
Exactitud* a
20 Hz hasta 45 Hz
Exactitud* de CC
y 45 Hz hasta 1 kHz
Exactitud* a
1 kHz hasta 20 kHz
Exactitud* a
20 kHz hasta 40 kHz
500,00 mV ± (1,5% + 0,4 mV) ± (0,5% + 0,4 mV) ± (1,0% + 0,4 mV) ± (3,5% + 0,4 mV)**
5,0000 V ± (1,5% + 0,004 V) ± (0,5% + 0,008 V) ± (1,2% + 0,004 V) ± (4,0% + 0,004 V)**
50,000 V ± (1,5% + 0,04 V) ± (0,5% + 0,08 V) ± (1,2% + 0,04 V) ± (4,0% + 0,04 V)**
500,00 V No especificada ± (0,5% + 0,8 V) No especificada No especificada
1000,0 V No especificada ± (0,5% + 8 V) No especificada No especificada
*
Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 80 dígitos.
**
Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 180 dígitos.
Desde 10% al 15% de la escala: Porcentaje de exactitud de lectura + 100 dígitos.
Lectura residual menor que 50 dígitos con los cables de prueba en cortocircuito.
Aviso: “Dígitos” se refiere al dígito menos significativo (el número en la posición más a la derecha).
Voltaje de VFD CA
Escala
Exactitud* a
5 Hz hasta 20 Hz
Exactitud* a
20 Hz hasta 200 Hz
Exactitud* a
200 Hz hasta 440 Hz
5,0000 V ± (3% + 0,008 V) ± (2% + 0,005 V) ± (6% + 0,008 V)**
50,000 V ± (3% + 0,08 V) ± (2% + 0,05 V) ± (6% + 0,08 V)**
500,00 V ± (3% + 0,8 V) ± (2% + 0,5 V) ± (6% + 0,8 V)**
1000,0 V ± (3% + 8 V) ± (2% + 5 V) ± (6% + 8 V)**
*
No está especificado para frecuencias fundamentales mayores que 440 Hz.
** La exactitud decrece linealmente de ± (2,0% + 50 dígitos) a 200 Hz hasta
± (6% + 80 dígitos) a 440 Hz.
DM-860A
45
Exactitud (continuación)
Voltaje alterno (CA)
Escala
Exactitud* a
20 Hz hasta 45 Hz
Exactitud* a
45 Hz hasta 65 Hz
Exactitud* a
65 Hz hasta 10 kHz
500,00 mV ± (1,2% + 0,4 mV) ± (0,3% + 0,2 mV) ± (0,4% + 0,25 mV)
5,0000 V ± (1,2% + 0,004 V) ± (0,3% + 0,003 V) ± (0,3% + 0,004 V)
50,000 V ± (1,2% + 0,04 V) ± (0,3% + 0,03 V) ± (0,3% + 0,04 V)
500,00 V No especificada ± (0,5% + 0,3 V) ± (0,5% + 0,4 V)
1000,0 V No especificada ± (0,5% + 3 V) ± (0,8% + 4 V) (65 Hz hasta 1 kHz)
Escala
Exactitud* a
10 kHz hasta 20 kHz
Exactitud* a
20 kHz hasta 100 kHz
500,00 mV ± (0,5% + 0,3 mV) ± (2,5% + 0,4 mV)**
5,0000 V ± (0,7% + 0,004 V) ± (3,5% + 0,004 V)**
50,000 V ± (0,7% + 0,04 V) ± (3,5% + 0,04 V)**
500,00 V ± (0,7% + 0,4 V) No especificada
1000,0 V No especificada No especificada
*
Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 80 dígitos.
**
Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 180 dígitos.
Lectura residual menor que 50 dígitos con los cables de prueba en cortocircuito.
Aviso: “Dígitos” se refiere al dígito menos significativo (el número en la posición más a la derecha).
Voltaje continuo (CC)
Escala Exactitud Impedancia de entrada
500,00 mV ± (0,02% + 0,02 mV) 10 MΩ, 80 pF nominales
5,0000 V ± (0,02% + 0,0002 V)
10 MΩ, 60 pF nominales
50,000 V ± (0,03% + 0,002 V)
500,00 V ± (0,04% + 0,02 V)
1000,0 V ± (0,15% + 0,2 V)
46
Exactitud (continuación)
Resistencia y conductancia
Escala Exactitud
Voltaje típico de
circuito abierto
500,00 Ω ± (0,07% + 0,10 Ω) 3,0 V CC
5,0000 kΩ ± (0,07% + 0,0002 kΩ)
1,3 V CC
50,000 kΩ ± (0,1% + 0,002 kΩ)
500,00 kΩ ± (0,1% + 0,02 kΩ)
5,0000 MΩ ± (0,3% + 0,0006 MΩ)
50,000 MΩ ± (2,0% + 0,006 MΩ)
99,99 nS ± (0,8% + 0,10 nS)*
*± (2,0% + 0,40 nS) por debajo de 9,99 nS.
Capacitancia
Escala Exactitud*
*
Estas exactitudes son para los capacitores de película
(capacitores con absorción dieléctrica insignificante).
**
En modo manual de detección de escala, las escalas
500,0 µF, 5,000 mF, y 25,00 mF no están especificadas
para valores menores de 45,0 µF, 0,450 mF, y 4,50 mF,
respectivamente.
50,00 nF ± (0,8% + 0,03 nF)
500,0 nF ± (0,8% + 0,3 nF)
5,000 µF ± (1,5% + 0,003 µF)
50,00 µF ± (2,5% + 0,03 µF)
500,0 µF** ± (3,5% + 0,5 µF)
5,000 mF** ± (5,0% + 0,005 mF)
25,00 mF** ± (6,5% + 0,05 mF)
Temperatura doble T1, T2, T1-T2
Escala Exactitud*
–50 °C a 1000,0 °C ± (0,3% + 1,5 °C)
–58 °F a 1832,0 °F ± (0,3% + 3,0 °F)
*
No se incluye la escala ni la exactitud del termopar.
DM-860A
47
Exactitud (continuación)
Frecuencia—Nivel de línea
Escala: 5,000 Hz a 200,00 kHz
Exactitud: ± (0,02% + 4 dígitos)
Escala de
función
CA
Sensibilidad
(sinusoidal, valores
RMS reales)
Escala
Escala de
función
CA
Sensibilidad
(sinusoidal, valores
RMS reales)
Escala
500 mV 100 mV
10 Hz a 200 kHz
500 µA 50 µA
10 Hz a 10 kHz
5 V 0,5 V 5000 µA 500 µA
50 V 5 V
10 Hz a 100 kHz
50 mA 5 mA
500 V 50 V 500 mA 50 mA
1000 V 500 V 10 Hz a 10 kHz 5 A 1 A
10 Hz a 3 kHz
VFD 5 V 0,5 V a 2 V*
10 Hz a 440 Hz
10 A 10 A
VFD 50 V 5 V a 20 V*
* La sensibilidad VFD decrece linealmente de 10% de la
escala a 200 Hz hasta 40% de la escala a 440 Hz.
VFD 500 V 50 V a 200 V*
Frecuencia—Nivel lógico
Escala: 5,000 Hz a 2,0000 MHz
Exactitud: ± (0,002% + 4 dígitos)
Sensibilidad: Onda rectangular de 2,5 Vp
% Ciclo de trabajo
Escala: 0,1% a 99,99%
Exactitud: ± (3 dígitos/kHz + 2 dígitos)
Frecuencia de entrada: 5 Hz a 500 kHz, familia lógica de 5 V
Verificación de diodos
Escala de medición: 2,0000 V
Corriente de prueba (típica): 0,4 mA
Voltaje de circuito abierto: < 3,0 V CC
Exactitud: ± (1% + 0,0001 V)
Continuidad
Umbral de tono: Entre 20 Ω y 200 Ω
Tiempo de respuesta: < 100 µs
dBm
La escala y la exactitud dependen de la función de CA utilizada y la impedancia de referencia
seleccionada.
Impedancia de referencia seleccionable: 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300,
500, 600, 800, 900, 1000, 1200 Ω
Captura de cresta (voltaje y corriente) para valores de cresta > 0,8 ms de duración
Exactitud: Exactitud especificada ± 100 dígitos
Resolución: 5000 dígitos
48
Especificaciones
Pantalla: LCD
Modo normal: 50.000 puntos
Modo de alta resolución: 500.000 puntos
Frecuencia: 99.999 puntos
Gráfico de barras de 41 segmentos
Polaridad: Automática
Impedancia de entrada: 10 MΩ, 60 pF nominales (80 pF para escalas de 500 mV).
Frecuencia de muestreo:
Modo de 50.000 puntos: 5 por segundo, nominal
Modo de 500.000 puntos: 1,25 por segundo, nominal
Pantalla de gráfico de barras: 60 por segundo
Coeficiente de temperatura: Nominal 0,15 x (Exactitud) por °C debajo de 18 °C desde 0 °C hasta 18 °C
(32 °F hasta 64 °F) o por encima de 28 °C desde 28 °C hasta 40 °C (82 °F hasta 104 °F) a menos
que se especifique de manera diferente
Apagado automático inteligente: Después de 17 minutos de inactividad
Indicación de pila sin carga: Por debajo de aproximadamente 7 V
Supresión de ruido*:
Factor de supresión en modo normal > 60 dB a 50 Hz y 60 Hz al efectuar mediciones de V CC
Factor de supresión en modo común > 90 dB de 0 Hz a 60 Hz al efectuar mediciones de V CA
Factor de supresión en modo común > 120 dB a 50 Hz y 60 Hz al efectuar mediciones de V CC
Condiciones de operación:
0 °C a 31 °C (32 °F a 88 °F), 0% a 80% de humedad relativa
31 °C a 45 °C (88 °F a 113 °F), humedad relativa disminuyendo linealmente de 80% a 50%
(sincondensación)
Altitud: 2000 m (6500 pies) máxima
Uso en interiores únicamente
Grado de contaminación: 2
Condiciones de almacenamiento: –20 °C a 60 °C (–4 °F a 140 °F), 0% a 80% de humedad relativa
(sin condensación)
Retire la pila
Pila: Pila de 9 voltios (NEDA 1604, JIS 006P o IEC 6F)
E.M.C.: Cumple EN61326-1:2006
En un campo de RF de 3 V/m:
No se especifica la función de capacitancia
Escalas para otras funciones: Exactitud total = Exactitud especificada + 1000 dígitos
No se especifica el desempeño por encima de 3 V/m
* Supresión del ruido es la capacidad de suprimir señales o ruido indeseados.
• Voltajes de modo normal son señales de CA que pueden ocasionar mediciones inexactas de CC.
NMRR (Normal Mode Rejection Ratio o Factor de supresión en modo normal) es una medición de
la capacidad para filtrar estas señales.
• Voltajes de modo común son señales presentes en las terminales de entrada + y COM, con
respecto a la conexión a tierra, que pueden causar alteraciones de dígitos o compensaciones en
las mediciones de voltaje. CMRR (Common Mode Rejection Ratio o Factor de supresión en modo
común) es una medición de la capacidad para filtrar estas señales.
DM-860A
49
Especificaciones (continuación)
Seguridad: Doble aislamiento por IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0,
IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 y CAN/CSA-C22.2 Nº 61010-1-12
Ed. 3.0 a Categoría IV 1000 V CA/CC.
Protecciones de sobrecarga:
V: 1100 V CC/CA rms
A: fusible 11 A/1000 V, capacidad de interrupción 20 kA, fusible F, 13/32" x 1-1/2"
µA y mA: fusible 0,44 A/1000 V, capacidad de interrupción 10 kA, fusible F, 13/32" x 1-3/8"
mV, Ω, y otras funciones: 1000 V CC/CA rms
DIRECTIVAS CENELEC: Los instrumentos se ajustan a la directiva CENELEC de bajo voltaje 2006/95/CE
y a la directiva de compatibilidad electromagnética 2004/108/CE
Categorías de medición
Las siguientes definiciones proceden de la norma de seguridad internacional sobre la coordinación de
aislamientos tal y como se aplica a equipos de medición, control y laboratorio. En las publicaciones
IEC 61010-1 y IEC 60664 de la International Electrotechnical Commission (Comisión Electrotécnica
Internacional) se detallan más a fondo estas categorías de medición.
Categoría de medición I
Nivel de señal. Equipo electrónico y de telecomunicaciones, o partes del mismo. Como ejemplo pueden
citarse los circuitos electrónicos protegidos contra tensiones momentáneas dentro de fotocopiadores y
modems.
Categoría de medición II
Nivel local. Aparatos eléctricos, equipo portátil, y los circuitos a los que están conectados. Como
ejemplo pueden citarse dispositivos de iluminación, televisores y circuitos de rama larga.
Categoría de medición III
Nivel de distribución. Máquinas instaladas permanentemente y los circuitos a los que están cableados.
Como ejemplo pueden citarse sistemas conductores y los paneles del interruptor automático principal
del sistema eléctrico de un edificio.
Categoría de medición IV
Nivel de abastecimiento primario. Líneas aéreas y otros sistemas de cable. Como ejemplo pueden
citarse cables, medidores, transformadores y cualquier otro equipo exterior perteneciente a la empresa
de servicio eléctrico.
Certificado de Conformidad
Greenlee Tools, Inc. cuenta con certificación conforme a ISO 9001:2008 para nuestros Sistemas de
Gerencia de Calidad.
El instrumento provisto ha sido inspeccionado y/o calibrado mediante el uso de equipo reconocido por
el Instituto Nacional de Normas y Tecnologías (National Institute for Standards and Technology [NIST]).
50
Mantenimiento
Peligro de electrocución:
Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad.
De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte.
Peligro de electrocución:
Los fusibles son una parte integral para la protección contra sobretensión. Cuando sea necesario
reemplazarlos, consulte la sección “Especificaciones” para saber qué tipo, tamaño y capacidad
deben tener. Utilizar cualquier otro tipo de fusible anulará la clasificación de protección de
sobretensión de la unidad.
De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte.
Cómo reemplazar la batería
1. Desconecte la unidad del circuito. Apague (OFF) la
unidad.
2. Extraiga los dos tornillos de la puerta de acceso a la
batería y retírela.
3. Cambie la batería y verifique la polaridad.
Cómo cambiar los fusibles
1. Desconecte la unidad del circuito. Apague (OFF) la
unidad.
2. Extraiga los dos tornillos de la puerta de acceso a la
batería y retírela.
3. Desenrosque los dos tornillos dentro del compartimiento
de la batería y los dos tornillos en la parte posterior del estuche.
4. Quite la cubierta posterior y cambie los fusibles.
5. Alinee las dos secciones de la unidad y las juntas de goma.
6. Asegúrese que el interruptor de selección esté en la posición original de modo que esté bien
alineado con el interruptor interno.
7. Vuelva a colocar la cubierta y los tornillos.
Limpieza y almacenamiento
Limpie periódicamente la caja utilizando un paño húmedo y detergente suave; no utilice abrasivos ni
solventes.
Si el medidor no se usará durante períodos de más de 60 días, extraiga la batería y guárdela
separadamente.
DM-860A
51
Description
Le multimètre numérique DM-860A de Greenlee est un appareil de contrôle portable offrant les
capacités de mesure suivantes : tension alternative ou continue, intensité alternative ou continue,
pourcentage de courant de boucle, deux canaux de température (thermocouples de type K), fréquence,
coefficient d'utilisation, résistance, conductance et capacité. Il permet également la vérification de
diodes et les contrôles de continuité.
Le DM-860A comporte un affichage à barres graphiques, qui répond plus rapidement que l’affichage
numérique — utile pour détecter les contacts défectueux, les déclics de potentiomètre et les pointes
de signal. Une interface informatique à isolation optique avec logiciel, proposée en option, permet
l'enregistrement des mesures de l'appareil sur un ordinateur.
Les autres fonctions et capacités spéciales sont notamment :
• Double afficheur présentant deux mesures, tension alternative et fréquence par exemple,
simultanément.
• Avertisseur Beep-Jack™ produisant un bip sonore et un message d'erreur à l'écran si le fil de
mesure est branché dans la borne d'entrée mA µA ou A alors que le sélecteur n'est pas en position
mA µA ou A.
• Bande passante en courant alternatif de 100 kHz pour la tension et de 20 kHz pour l'intensité.
• Fonction MAX/MIN, qui met en mémoire le maximum, le minimum et la moyenne.
• Mode de saisie de crête, pour saisir les maxima des signaux de tension ou d'intensité.
• Résolution sélectionnable entre 50 000 ou 500 000 points pour les mesures de tension continue.
• Mode de zéro relatif.
• Calibre automatique ou manuel.
• Mise hors tension automatique intelligente.
• Affichage à cristaux liquides rétroéclairé pour les mesures dans la pénombre.
Sécurité
Lors de l’utilisation et de l’entretien des outils et des équipements de Greenlee, votre sécurité est
une priorité. Ce manuel d’instructions et toute étiquette sur l’outil fournit des informations permettant
d’éviter des dangers ou des manipulations dangereuses liées à l’utilisation de cet outil. Suivre toutes
les consignes de sécurité indiquées.
Dessein de ce manuel
Ce manuel d’instructions a pour objet de familiariser tout le personnel avec les procédures préconisées
pour une utilisation et un entretien sans danger du multimètre numérique DM-860A de Greenlee.
Mettre ce manuel à la disposition de tous les employés. On peut obtenir des exemplaires gratuits sur
simple demande sur le site Web www.greenlee.com.
Ne pas se débarrasser de ce produit ou le jeter !
Pour des informations sur le recyclage, visiter www.greenlee.com.
52
SYMBOLE D’AVERTISSEMENT
Ce symbole met en garde contre les risques et les manipulations dangereuses pouvant entraîner
des blessures ou l’endommagement du matériel. Le mot indicateur, défini ci-dessous, indique la
gravité du danger. Le message qui suit le mot indicateur indique comment empêcher le danger.
Danger immédiat qui, s’il n’est pas pris en considération ENTRAINERA des blessures graves, voire
mortelles.
Danger qui, s’il n’est pas pris en considération, POURRAIT entraîner des blessures graves, voire
mortelles.
Dangers ou manipulations dangereuses qui, s’ils ne sont pas pris en considération, POURRAIENT
EVENTUELLEMENT entraîner des dommages à la propriété ou causer des blessures.
Lire attentivement et bien comprendre cette documentation avant d’utiliser ou
de procéder à l’entretien de cet équipement. Négliger de comprendre comment
utiliser cet outil en toute sécurité pourrait provoquer un accident et entraîner des
blessures graves, voire mortelles.
Risque de décharge électrique :
Un contact avec des circuits sous tension pourrait entraîner des blessures
graves, voire mortelles.
Consignes de sécurité importantes
Toutes les spécifications sont nominales et peuvent changer avec l’amélioration de la conception. Greenlee Tools, Inc.
ne peut être tenue responsable des dommages résultant d’une application inappropriée ou d’un mauvais usage de
ses produits.
® Déposé : La couleur verte des instruments de vérification électrique est une marque déposée de
Greenlee Tools, Inc.
Beep-Jack est une marque de commerce de BTC.
Microsoft et Windows sont des marques déposées de Microsoft Corporation.
CONSERVER CE MANUEL
DM-860A
53
Consignes de sécurité importantes
Risques de décharge électrique et d’incendie:
• Ne pas exposer cet appareil à la pluie ou à l’humidité.
• Ne pas utiliser cet appareil s’il est mouillé ou endommagé.
• Utilisez exclusivement les fils de test fournis avec l’équipement ou des sondes homologuées UL
ayant une qualification identique ou supérieure.
• Vérifier les fils d’essai ou l’accessoire avant de les utiliser. La pièce (ou les pièces) doi(ven)t être
propre(s) et sèche(s) et l’isolation en bon état. Si la couche isolante interne, de couleur contrastée,
est visible, n’utilisez pas le fil.
• Utiliser cet appareil uniquement dans le but pour lequel il a été conçu, tel que décrit dans ce
manuel. Toute autre utilisation peut altérer le système de protection de cet appareil.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles.
Risques de décharge électrique:
• Ne pas appliquer plus que la tension nominale entre deux bornes d’entrée, ou entre une borne
d’entrée et une prise de terre.
• Ne pas entrer en contact avec les extrémités des fils d’essai ou avec toute autre partie non isolée
de l’accessoire.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles.
Risques de décharge électrique:
• Ne pas utiliser lorsq ue le boîtier est ouvert.
• Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles.
Risques de décharge électrique:
Les fusibles forment une partie intégrante du système de protection de surtension. Lorsqu’un fusible
doit être remplacé, consulter les caractéristiques techniques pour connaître le type, la taille et la
capacité requis. L’utilisation de tout autre type de fusible annule l’étalonnage de protection contre la
surtension de l’appareil.
L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles.
54
Consignes de sécurité importantes
Risques de décharge électrique:
• Sauf si l’on mesure la tension, le courant ou la fréquence, mettre hors tension et couper la source
d’alimentation. S’assurer que tous les condensateurs sont déchargés. Aucune tension ne doit être
présente.
• Régler le sélecteur et connecter les fils d’essai pour qu’ils correspondent à la mesure voulue. Des
réglages ou des connexions incorrects peuvent faire sauter les fusibles.
• L’utilisation de cet appareil à proximité d’équipements qui génèrent des interférences
électromagnétiques peut produire des lectures instables ou erronées.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles.
Risques de décharge électrique:
Ne pas modifier la fonction de mesure pendant que les fils d’essai sont connectés à un composant
ou à un circuit.
L’inobservation de cette consigne pourrait endommager l’appareil et pourrait entraîner des blessures.
Risques de décharge électrique:
• Ne pas tenter de réparer cet appareil. Il ne comporte aucune pièce pouvant être réparée.
• Ne pas exposer l’appareil à des températures ou à une humidité extrêmes.
Voir les caractéristiques techniques.
L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner des blessures.
DM-860A
55
Identification
1. Affichage Cristaux liquides (LCD) et graphique à barres
2. Boutons Voir les explications sous « Utilisation des fonctions »
de fonctions
3. Sélecteur Sélectionne une fonction ou met hors tension (OFF).
4. A Borne d’entrée positive pour les mesures d'intensités élevées ;
borne d'entrée négative pour T2
5. mA µA Borne d’entrée positive pour les mesures de faibles intensités ;
borne d'entrée positive pour T2
6. COM Borne d’entrée négative, commune ou de terre pour toutes les mesures
7. ΩV Borne d’entrée positive pour toutes les mesures sauf l'intensité
1
3
2
4 7
5 6
Symboles apparaissant sur l’appareil
Avertissement — Lire le manuel d’instructions
Isolation double
56
Affichage principal
8.
Segment de graphique à barres
9. Indicateur de polarité pour
le graphique à barres
10. Échelle du graphique à barres
11. Fonction de zéro relatif activée
12. VFD Fonction VFD activée
13. Indicateur de polarité
14. 8.8.8.8.88 Affichage numérique
15. T1-T2 Fonction T1, T2, ou T1-T2 activée
16. Mesure de courant alternatif
sélectionnée
17. Mesure de courant continu
sélectionnée
18. MAX Valeur maximale enregistrée
ouaffichée
19. MIN Valeur minimale enregistrée
ou affichée
20. AVG Valeur moyenne enregistrée
ou affichée
21. Fonction d’enregistrement activée
22. Fonction de saisie de crête activée
23. Fonction de rétention activée
24. Sélection de calibre automatique
activée
25. Continuité
26. Pile déchargée
27. } Symbole de surcharge
(graphique à barres)
28. 5 Indicateur de plage maximale du
graphique à barres
29. D% Fonction de coefficient
d'utilisation
activée
30. k Kilo (10
3
)
31. M Méga (10
6
)
32. Ω Ohm
33. Hz Hertz (fréquence en cycles
par seconde)
34. dBm Décibel
35. m Milli (10
-3
)
36. µ Micro (10
-6
)
37. V Volt
38. A Ampère
39. n Nano (10
-9
)
40. F Farad
41. S Siemens
Affichage secondaire
42. %4-20mA Fonction de courant de boucle
de régulation de procédé
activée
43. µ Micro (10
-6
)
44. m Milli (10
-3
)
45. A Ampère
46. V Volt
47. M Méga (10
6
)
48. k Kilo (10
3
)
49. Hz Hertz (fréquence en cycles
par seconde)
50. 8.8.8.8 Affichage numérique
51. T2 Fonction T2 activée
52. Mesure de courant alternatif
sélectionnée
53. Indicateur de polarité
Icônes de l’afficheur
24
21-23
18-20
16-17
15
12
11
10
8-9
13-14
47-49
43-46
42
29-41
27
28
2625
51-53
50
DM-860A
57
Double affichage numérique : Cet appareil peut afficher simultanément deux mesures, la tension
alternative et la fréquence par exemple. Les combinaisons d'affichage sont indiquées au moyen de
symboles de grande taille pour l'affichage principal et de symboles plus petits en hauteur pour les
mesures sur l'affichage secondaire. Par exemple, « VAC
Hz
» signifie que l'affichage principal présente
une mesure de tension alternative et l'affichage secondaire la mesure de fréquence correspondante.
VFD ~V et VFD Hz : Ces fonctions font appel à des algorithmes de filtrage et d'élimination du bruit
pour effectuer des mesures de tension et de fréquence précises sur la majorité des commandes à
fréquence variable (VFD). La mesure de tension sélectionne automatiquement le calibre 500 V. Utiliser
le bouton RANGE pour sélectionner d'autres calibres uniquement si cela est nécessaire. La sensibilité
des mesures de fréquence de VFD dépend du calibre de tension et de la fréquence d'entrée.
Voir«Fréquence – Niveau de ligne » dans la section « Précision » de ce manuel.
SELECT : Appuyer brièvement pour passer d'une fonction, d'un mode de mesure ou d'un mode
d'affichage à l'autre. Le dernier réglage utilisé devient le réglage par défaut lorsque la fonction
considérée est sélectionnée une nouvelle fois. Pour changer de réglage par défaut, en sélectionner
un nouveau. Le réglage est conservé dans une mémoire non volatile.
RANGE : Appuyer une fois pour passer en mode de sélection manuelle du calibre. L'icône
disparaît de l'afficheur. Appuyer de façon répétée pour faire défiler les calibres. Tenir enfoncé pour
revenir au mode de sélection automatique du calibre.
Remarque : Lors de l’utilisation du mode CREST, REC, HOLD ou ∆, appuyer sur RANGE pour quitter
ce mode.
∆ : Calcule la différence entre deux mesures. Pendant la mesure, appuyer sur pour ramener
l'affichage à zéro. L’icône apparaît sur l’afficheur. Effectuer la deuxième mesure. La valeur affichée
représente la différence entre les deux mesures. Appuyer une nouvelle fois pour quitter ce mode.
Cette fonction s'applique à l'affichage principal seulement.
HOLD : Appuyer brièvement pour figer l'affichage de la valeur courante. Appuyer une nouvelle fois
pour quitter ce mode.
Cette fonction n'a aucun effet sur le graphique à barres.
CREST : Appuyer brièvement pour activer le mode d'enregistrement de crête. Dans ce mode, la
valeur d'entrée est mesurée toutes les 1 ms. et « MAX » s'affichent à l'écran. La valeur de crête
maximale est affichée. L'appareil émet un bip à chaque mise à jour du maximum ou du minimum.
Appuyer de façon répétée pour sélectionner l'affichage souhaité : valeur de crête maximale ou
minimale. Tenir enfoncé pour quitter ce mode.
La fonction de mise hors tension automatique est désactivée lorsque cette fonction est utilisée.
Remarque : Lors de l'utilisation de la fonction CREST, appuyer sur RANGE pour quitter ce mode.
REC : Appuyer brièvement pour activer le mode d'enregistrement MAX/MIN/AVG. La valeur
d'entrée est mesurée toutes les 50 ms dans ce mode. « MAX MIN » et « AVG »* s'affichent à
l'écran. La valeur d'entrée instantanée est affichée. L'appareil émet un bip à chaque mise à jour
du maximum ou du minimum. Appuyer de façon répétée pour sélectionner l'affichage souhaité :
maximum, minimum, moyenne ou entrée instantanée. Tenir enfoncé pour quitter ce mode.
La fonction de mise hors tension automatique est désactivée lorsque cette fonction est utilisée.
Remarque : Lors de l'utilisation de la fonction REC, appuyer sur RANGE pour quitter ce mode.
Utilisation des fonctions
58
Utilisation des fonctions (suite)
: Maintenir enfoncé jusqu'à ce que le rétroéclairage s'allume. Maintenir enfoncé une nouvelle
fois pour l'éteindre. Le rétroéclairage s’éteint au bout de 30 secondes pour économiser la pile.
dBm-Ω : L'impédance de référence s'affiche pendant 1 seconde une fois que la fonction dBm est
sélectionnée. Appuyer brièvement sur dBm-Ω pour changer l'impédance de référence. Voir les
valeurs disponibles dans la section « Caractéristiques techniques ».
Remarque : Ceci est une mesure de tension alternative calculée suivant la formule
dBm = 20 x log (tension mesurée / tension de référence)
La tension de référence et la tension qui produit la dissipation de 1 mW de puissance dans
l'impédance de référence sélectionnée.
T1-T2 : Appuyer brièvement pour sélectionner l'affichage de température souhaité :
T1, T2, T1
T2
, ouT1-T2
T2
.
500000 : Tenir enfoncé pour alterner entre le mode rapide à 50 000 points et le mode haute
résolution à 500 000 points pour les mesures de tension continue.
Mise hors tension automatique intelligente (APO) : Pour prolonger l'autonomie de la pile, le
multimètre s’éteint automatiquement au bout de 17 minutes d’inactivité environ. L'inactivité se
produit lorsqu'aucun bouton n'est enfoncé et que le sélecteur n'est pas actionné. Le multimètre
n'entre pas en mode APO s'il y a des mesures significatives de plus de 10 % du calibre ou des
mesures de résistance et de continuité sans surcharge. Pour remettre sous tension, appuyer sur
SELECT, RANGE, ou HOLD ou mettre le sélecteur sur OFF puis le remettre en position de marche.
Pour désactiver cette fonction, appuyer sur SELECT alors que l'appareil est en marche.
Désactivation du bip sonore : Tenir le bouton RANGE enfoncé tout en mettant l'appareil sous
tension pour désactiver provisoirement la fonction de bip sonore. Mettre le sélecteur sur OFF puis le
remettre en position de marche pour rétablir le bip sonore.
Hz : La fréquence peut être mesurée pour la majorité des réglages de tension et d'intensité du
sélecteur. Appuyer sur SELECT jusqu'à afficher « Hz », au choix, dans l'affichage primaire ou
secondaire. La sensibilité de la fonction de fréquence de niveau de ligne varie en fonction du calibre
de mesure. Voir « Caractéristiques techniques ». Les mesures par calibre automatique présentent
habituellement le meilleur niveau de déclenchement. Si la mesure de fréquence devient instable ou
disparaît, appuyer sur le bouton RANGE pour sélectionner un autre niveau de déclenchement.
%4-20mA : Cette valeur calculée est l'une des trois options disponibles pour l'affichage secondaire
lors de la mesure d'intensités continues en milliampères. Elle est utile pour les mesures de boucles
de régulation de procédé industriel de 4-20 mA. Une mesure de 4 mA sur l'affichage principal produit
une mesure de 0 % sur l'affichage secondaire, 12 mA produit 50 %, 20 mA produit 100 %, etc.
DM-860A
59
Mesure de courant alternatif
En règle générale, les mesures de courant alternatif sont affichées en valeurs efficaces (RMS). La
valeur efficace équivaut à la valeur d’une forme d’onde de courant continu, qui fournirait la même
puissance si elle remplaçait la forme d’onde qui varie en fonction du temps. Les deux méthodes de
mesure du courant alternatif sont la mesure de valeur efficace de réponse moyenne étalonnée et la
mesure de valeur efficace vraie.
La méthode par valeur efficace de réponse moyenne étalonnée consiste à mesurer la valeur moyenne
du signal d’entrée après un redressement à double alternance, à la multiplier par 1,11 et à afficher le
résultat. Cette méthode est précise si le signal d’entrée est une onde sinusoïdale pure.
La méthode par mesure de la valeur efficace vraie fait appel à un circuit interne permettant de
mesurer directement la valeur efficace. Cette méthode est précise dans les limites du facteur de crête
spécifiées, que le signal soit une onde sinusoïdale pure, une onde carrée, une onde triangulaire, une
demi-onde ou un signal comportant des harmoniques. Les appareils à mesure de valeur efficace vraie
sont beaucoup plus polyvalents que les appareils conventionnels. Le DM-860A de Greenlee offre des
mesures de valeur efficace vraie.
Le tableau des formes d’onde et facteurs de crête fournit les valeurs efficaces des signaux alternatifs
courants.
Formes d’ondes et facteurs de crêtes
Forme d’onde
Valeur RMS 100 100 100 100
Valeur moyenne 90 100 87 64
Facteur de crête*
(x)
1,414 1 1,73 2
* Le facteur de crête correspond au rapport de la valeur de crête sur la valeur efficace; il est
représenté par la lettre grecque x.
Valeur efficace vraie AC + DC
La valeur efficace vraie AC + DC distingue les composantes alternative et continue suivant l'expression
données par l’expression
lors de la prise des mesures et reproduit avec précision la valeur efficace vraie totale réelle
indépendamment de la forme d’onde. Les formes d’ondes déformées par la présence de composantes
continues et d’harmoniques peuvent entraîner:
• une surchauffe des transformateurs, des groupes électrogènes et des moteurs
• un déclenchement prématuré des disjoncteurs
• une condition où les fusibles vont griller
• une surchauffe des neutres à cause de la triple harmonique présente dans le neutre
• une vibration des barres omnibus et des panneaux électriques
60
Bande passante en courant alternatif
La bande passante en courant alternatif d’un multimètre numérique (DMM) est la gamme des
fréquences qui permettent d’effectuer des mesures de courant alternatif avec la précision requise.
Elle constitue la réponse de fréquence de ces fonctions et non leur mesure de fréquence. Un DMM ne
peut mesurer avec précision la valeur alternative pour des spectres de fréquences hors de la bande
passante en courant alternatif du DMM. En conséquence, une bande passante large est d'une grande
importance pour les DMM à haute performance. Les formes d’ondes complexes et déformées, de
même que le bruit, contiennent des composantes de fréquences bien supérieures à un bruit haute
fréquence comme, par exemple, celui d’une ligne sous tension à 50/60 Hz.
Utilisation
Risque de décharge électrique :
Un contact avec des circuits sous tension pourrait entraîner des blessures
graves, voire mortelles.
Mode d'autodiagnostic
Le message « rE-O » peut s'afficher à la mise en marche du multimètre. Il indique que l'appareil est
en train d'exécuter un autodiagnostic de routine. Ne pas le mettre à l'arrêt. Laisser la procédure de
diagnostic se terminer. Si le message « C_Er » s'affiche à la mise en marche du multimètre, il est
possible que certains calibres soient largement hors limites. Pour éviter les erreurs de mesure, cesser
d'utiliser le multimètre et le renvoyer à Greenlee pour être réétalonné.
Mode d'emploi
1. Se reporter au Tableau des réglages. Placer le sélecteur sur le réglage qui convient, appuyer sur
SELECT (lorsque l'instruction en est donnée) et raccorder les fils d'essai au multimètre.
2. Voir les instructions de mesure particulières sous « Mesures types ».
3. Tester l’appareil sur un circuit ou un composant connu.
• Si l’appareil ne fonctionne pas comme prévu sur un circuit opérationnel connu, changer la pile et/
ou les fusibles.
• Si l’appareil ne fonctionne toujours pas comme prévu, appeler le service d'assistance technique
de Greenlee au 800-435-0786.
4. Effectuer la mesure sur le circuit ou le composant à contrôler.
DM-860A
61
Utilisation (suite)
Tableau des réglages
Le multimètre conserve la dernière fonction utilisée pour chaque position du sélecteur dans sa
mémoire non volatile. Après avoir réglé le sélecteur, si cette fonction n'est pas celle souhaitée, appuyer
sur SELECT jusqu'à ce que l'icône souhaitée s'affiche.
Les options de double affichage sont indiquées en même temps que les icônes. Dans le tableau,
«~V
Hz
» signifie que « ~ » et « V » apparaissent dans l'affichage principal et « Hz » dans l'affichage
secondaire. Cette combinaison présente la mesure de tension alternative dans l'affichage principal et la
fréquence correspondante dans l'affichage secondaire.
Pour mesurer cette
caractéristique …
Régler le
sélecteur sur ce
symbole …
Appuyer sur SELECT
jusqu'à l'affichage de
ces icônes …
Raccorder
le fil rouge
à …
Raccorder
le fil noir
à …
Commande à vitesse variable—
Tension et fréquence
V
Hz
ou Hz
~V
ΩV
COM
TensionValeur eff. vraie alt.
(1000 V max)
V
Hz
ou Hz
~V
ΩV
COM
*Tension—Continue
(1 000 V max)
V ou V
~V
ΩV
COM
Tension—Valeur eff. vraie
alt. + cont. (1000 V max)
V
~V
ΩV
COM
Tension—Continue
(500 mV max)
mV ou mV
~mV
ΩV
COM
Tension—Valeur eff. vraie
alt. + cont. (500 mV max)
mV
~mV
ΩV
COM
Tension—Valeur eff. vraie
alternative (500 V max)
mV
Hz
ou Hz
~mV
ΩV
COM
Fréquence—Tension ou
intensité de niveau de ligne
Régler sur tension
ou intensité
suivant ce tableau.
Toute option d'affichage
qui inclut Hz
**Fréquence—Niveau logique
Hz
Hz
ΩV
COM
Coefficient d'utilisation (%) D% D%
ΩV
COM
dBm (0 dB = 1 mW dans
l'impédance de référence)
dBm
(fonction
1000V max ;
fonction
500mV max.)
Impédance de référence
et dBm pendant 1 s,
puis dBm
Hz
(appuyer sur
dBm-Ω pour changer
d'impédance de
référence)
ΩV
COM
* Pour effectuer des mesures précises, appuyer sur 500000 pour alterner entre 50 000 points et
500 000 points de mesure. S'applique aux tensions continues seulement.
** La fréquence de niveau logique a une sensibilité fixe et s'utilise avec des signaux numériques.
Voir« Précision ».
Ce tableau continue à la page suivante.
62
Tableau des réglages (suite)
Pour mesurer cette
caractéristique …
Régler le
sélecteur sur ce
symbole …
Appuyer sur SELECT
jusqu'à l'affichage de
ces icônes …
Raccorder
le fil rouge
à …
Raccorder
le fil noir
à …
Double température T1T2
°C ou °F (appuyer sur
RANGE pour les options
d'affichage T1, T2, T1
T2
ou T1-T2
T2
)
Voir les
Notes
1et 2
†Capacité F
ΩV
COM
Diode V et diod
ΩV
COM
Résistance Ω Ω
ΩV
COM
Continuité
et Ω
ΩV
COM
Conductance nS nS
ΩV
COM
Intensité—Valeur eff. vraie
alt., cont. ou alt. + cont
(10 A max)
A
A, A
~A,
A
~A,
ou A
Hz
A COM
Intensité—Valeur eff. vraie
alt., cont. ou alt. + cont.
(600 mA max)
mA
mA
%4-20mA,
mA
~mA,
mA
~mA,
ou mA
Hz
mA µA COM
Intensité—Valeur eff. vraie
alt., cont. ou alt. + cont.
(6 000 µA max)
µA
µA, µA
~µA,
µA
~µA,
ou µA
Hz
mA µA COM
Courant de boucle de régulation
de procédé industriel
% 4 à 20 mA
mA
mA
%4-20mA
mA µA COM
Décharger les condensateurs avant la mesure. Voir « Mesures types » concernant les
condensateurs polarisés
Note 1: Raccorder T1+ à ΩV et T1– à COM.
Note 2: Raccorder T2+ à mA µA and T2à A.
Utilisation (suite)
DM-860A
63
Mesures types
Mesure de tension
Mesure d’intensité
64
Mesures types
Contrôle de continuité
Mesure de capacité Mesure de diode
Mesure de résistance
Polarisation
inverse
Polarisation
directe
Remarque: Pour les condensateurs polarisés,
raccorder le fil rouge à la borne positive et le fil
noir à la borne négative du condensateur.
DM-860A
65
Mesures types
Température
66
Utilisation du logiciel en option
Le DM-860A est compatible avec le DMSC-9U de Greenlee, un système de câble et logiciel d’interface
informatique à isolation optique. Il permet de transférer les mesures vers un micro-ordinateur utilisant
le système d’exploitation Microsoft
®
Windows
®
.
Installation du logiciel
1. Introduire le CD dans le lecteur CDROM de l’ordinateur.
2. Le programme d’installation devrait démarrer automatiquement. S’il ne démarre pas, double-
cliquer sur l’icône du CD dans «Poste de travail».
3. Le menu du programme d’installation s’affiche. Cliquer sur «Software Installation».
4. Entrer le numéro de référence du multimètre (par exemple, «DM-860A») dans la boîte de dialogue.
5. Répondre aux boîtes de dialogue suivantes pour définir les préférences de l’utilisateur.
Raccordement du câble d’interface USB optique
1. Aligner la clavette du connecteur avec la rainure sur le multimètre.
2. Tourner le connecteur dans le sens des aiguilles d’une montre pour l’enclencher.
3. Raccorder le câble à un port USB de l’ordinateur.
Rainure de clavette au dos du multimètre
DM-860A
67
Précision
Voir les conditions d’utilisation et le coefficient de température dans la section
« Caractéristiquestechniques».
La précision est spécifiée comme suit: ± (un pourcentage de la mesure + une quantité fixe)
à 23 °C ± 5 °C (73,4 °F ± 9 ºF), 0% à 75% d’humidité relative. Ces caractéristiques concernent le
mode à 50 000 points.
Mesures de valeur efficace vraie (True RMS): Sauf indication contraire, les précisions de tension et
d’intensité spécifiées s’appliquent de 5% à 100% du calibre. La fréquence doit être dans les limites de
la largeur de bande spécifiée pour les ondes non sinusoïdales. Les facteurs de crête sont les suivants:
• Facteur de crête < 2,1 : 1 à pleine échelle
• Facteur de crête < 4,2 : 1 à mi-échelle
Intensité AC, DC
AC
et AC + DC
AC
Calibre
Précision cour. cont.
et de 50 Hz à 60 Hz
Précision de
40 Hz à 1 kHz
Précision de
1 kHz à 20 kHz
Précision de
20 kHz à 100 kHz
500,00 µA ± (0,5% + 0,5 µA) ± (0,7% + 0,5 µA) ± (2,0% + 0,5 µA) ± (5,0% + 0,5 µA)
5000,0 µA ± (0,5% + 5,0 µA) ± (0,7% + 5,0 µA) ± (2,0% + 5,0 µA) ± (5,0% + 5,0 µA)
50,000 mA ± (0,5% + 0,05 mA) ± (0,7% + 0,05 mA) ± (2,0% + 0,05 mA) ± (5,0% + 0,05 mA)
500,00 mA ± (0,5% + 0,5 mA) ± (0,7% + 0,5 mA) ± (2,0% + 0,5 mA) ± (5,0% + 0,5 mA)
5,0000 A ± (0,5% + 0,005 A) ± (0,7% + 0,005 A) Non spécifié Non spécifié
10,000 A* ± (0,5% + 0,05 A) ± (0,7% + 0,05 A) Non spécifié Non spécifié
*
10 A continus ; 20 A maximum (coeff. d'utilisation : 30 s activé, 5 min désactivé).
Calibre
Tensions absorbées
(toutes plages de fréquence)
500,00 µA
0,15 mV/µA
5000,0 µA
50,000 mA
3,3 mV/mA
500,00 mA
5,0000 A
45 mV/A
10,000 A
Intensité continue
Calibre Précision Tensions absorbées
500,00 µA ± (0,15% + 0,2 µA)
0,15 mV/µA
5000,0 µA ± (0,1% + 2,0 µA)
50,000 mA ± (0,15% + 0,02 mA)
3,3 mV/mA
500,00 mA ± (0,15% + 0,3 mA)
5,0000 A ± (0,5% + 0,002 A)
45 mV/A
10,000 A* ± (0,5% + 0,02 A)
*
10 A continus ; 20 A maximum (coeff. d'utilisation : 30 s activé, 5 min désactivé).
Intensité AC, DC
AC
et AC + DC
AC
68
Précision (suite)
Tension DC
AC
et AC + DC
AC
Calibre
Précision* de
20 Hz à 45 Hz
Précision*
cour. cont. et
de 45 Hz à 1 kHz
Précision* de
1 kHz à 20 kHz
Précision* de
20 kHz à 40 kHz
500,00 mV ± (1,5% + 0,4 mV) ± (0,5% + 0,4 mV) ± (1,0% + 0,4 mV) ± (3,5% + 0,4 mV)**
5,0000 V ± (1,5% + 0,004 V) ± (0,5% + 0,008 V) ± (1,2% + 0,004 V) ± (4,0% + 0,004 V)**
50,000 V ± (1,5% + 0,04 V) ± (0,5% + 0,08 V) ± (1,2% + 0,04 V) ± (4,0% + 0,04 V)**
500,00 V Non spécifié ± (0,5% + 0,8 V) Non spécifié Non spécifié
1000,0 V Non spécifié ± (0,5% + 8 V) Non spécifié Non spécifié
*
De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 80 chiffres.
**
De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 180 chiffres.
De 10 % à 15 % du calibre : Pourcentage de précision de mesure + 100 chiffres.
Mesure résiduelle moins de 50 chiffres avec fils d'essai en court circuit
Remarque : « Chiffres » fait référence au chiffre le moins significatif (le chiffre le plus à droite
dunombre).
Tension VFD AC
Calibre
Précision* de
5 Hz à 20 Hz
Précision* de
20 Hz à 200 Hz
Précision* de
200 Hz à 440 Hz
5,0000 V ± (3% + 0,008 V) ± (2% + 0,005 V) ± (6% + 0,008 V)**
50,000 V ± (3% + 0,08 V) ± (2% + 0,05 V) ± (6% + 0,08 V)**
500,00 V ± (3% + 0,8 V) ± (2% + 0,5 V) ± (6% + 0,8 V)**
1000,0 V ± (3% + 8 V) ± (2% + 5 V) ± (6% + 8 V)**
*
Non spécifiée pour une fréquence fondamentale supérieure à 440 Hz.
** La précision diminue linéairement de ± (2,0 % + 50 chiffres) à 200 Hz à
± (6 % + 80 chiffres) à 440 Hz.
DM-860A
69
Précision (suite)
Tension AC
Calibre
Précision* de
20 Hz à 45 Hz
Précision* de
45 Hz à 65 Hz
Précision* de
65 Hz à 10 kHz
500,00 mV ± (1,2% + 0,4 mV) ± (0,3% + 0,2 mV) ± (0,4% + 0,25 mV)
5,0000 V ± (1,2% + 0,004 V) ± (0,3% + 0,003 V) ± (0,3% + 0,004 V)
50,000 V ± (1,2% + 0,04 V) ± (0,3% + 0,03 V) ± (0,3% + 0,04 V)
500,00 V Non spécifié ± (0,5% + 0,3 V) ± (0,5% + 0,4 V)
1000,0 V Non spécifié ± (0,5% + 3 V) ± (0,8% + 4 V) (65 Hz à 1 kHz)
Calibre
Précision* de
10 kHz à 20 kHz
Précision* de
20 kHz à 100 kHz
500,00 mV ± (0,5% + 0,3 mV) ± (2,5% + 0,4 mV)**
5,0000 V ± (0,7% + 0,004 V) ± (3,5% + 0,004 V)**
50,000 V ± (0,7% + 0,04 V) ± (3,5% + 0,04 V)**
500,00 V ± (0,7% + 0,4 V) Non spécifié
1000,0 V Non spécifié Non spécifié
*
De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 80 chiffres.
**
De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 180 chiffres.
Mesure résiduelle moins de 50 chiffres avec fils d'essai en court circuit
Remarque : « Chiffres » fait référence au chiffre le moins significatif (le chiffre le plus à droite
dunombre).
Tension DC
Calibre Précision Impédance d’entrée
500,00 mV ± (0,02% + 0,02 mV) 10 MΩ, 80 pF nominal
5,0000 V ± (0,02% + 0,0002 V)
10 MΩ, 60 pF nominal
50,000 V ± (0,03% + 0,002 V)
500,00 V ± (0,04% + 0,02 V)
1000,0 V ± (0,15% + 0,2 V)
70
Précision (suite)
Résistance et conductance
Calibre Précision
Tension circuit
ouverttype
500,00 Ω ± (0,07% + 0,10 Ω) 3,0 VDC
5,0000 kΩ ± (0,07% + 0,0002 kΩ)
1,3 VDC
50,000 kΩ ± (0,1% + 0,002 kΩ)
500,00 kΩ ± (0,1% + 0,02 kΩ)
5,0000 MΩ ± (0,3% + 0,0006 MΩ)
50,000 MΩ ± (2,0% + 0,006 MΩ)
99,99 nS ± (0,8% + 0,10 nS)*
*
± (2,0 % + 0,40 nS) en dessous de 9,99 nS.
Capacité
Calibre Précision*
*
Précisions valables pour les condensateurs à couches
(absorption diélectrique négligeable).
**
En mode de sélection manuelle du calibre, la précision
des calibres 500,0 µF, 5,000 mF et 25,00 mF n'est pas
spécifiée en dessous de 45,0 µF, 0,450 mF et 4,50 mF
respectivement.
50,00 nF ± (0,8% + 0,03 nF)
500,0 nF ± (0,8% + 0,3 nF)
5,000 µF ± (1,5% + 0,003 µF)
50,00 µF ± (2,5% + 0,03 µF)
500,0 µF** ± (3,5% + 0,5 µF)
5,000 mF** ± (5,0% + 0,005 mF)
25,00 mF** ± (6,5% + 0,05 mF)
Double température T1, T2, T1-T2
Plage Précision*
–50 °C à 1000,0 °C ± (0,3% + 1,5 °C)
–58 °F à 1832,0 °F ± (0,3% + 3,0 °F)
*
Précision et plage du thermocouple
non inclus.
DM-860A
71
Précision (suite)
Fréquence — Niveau de ligne
Plage : 5,000 Hz à 200,00 kHz
Précision : ± (0,02 % + 4 chiffres)
Calibre
fonction AC
Sensibilité
(eff. sinusoïdal)
Plage
Calibre
fonction AC
Sensibilité
(eff. sinusoïdal)
Plage
500 mV 100 mV
10 Hz à 200 kHz
500 µA 50 µA
10 Hz à 10 kHz
5 V 0,5 V 5000 µA 500 µA
50 V 5 V
10 Hz à 100 kHz
50 mA 5 mA
500 V 50 V 500 mA 50 mA
1000 V 500 V 10 Hz à 10 kHz 5 A 1 A
10 Hz à 3 kHz
VFD 5 V 0,5 V à 2 V*
10 Hz à 440 Hz
10 A 10 A
VFD 50 V 5 V à 20 V*
*
La sensibilité VFD décroît linéairement de 10 %
du calibre à 200 Hz à 40 % du calibre à 440 Hz.
VFD 500 V 50 V à 200 V*
Fréquence — Niveau logique
Plage : 5,000 Hz à 2,0000 MHz
Précision : ± (0,002 % + 4 chiffres)
Sensibilité : Signal carré 2,5 Vp
Coefficient d'utilisation (%)
Plage : 0,1 % à 99,99 %
Précision : ± (3 chiffres/kHz + 2 chiffres)
Fréquence d'entrée : 5 Hz à 500 kHz, famille de circuits logiques de 5 V
Contrôle de diode
Calibre de mesure : 2,0000 V
Intensité de contrôle (type) : 0,4 mA
Tension en circuit ouvert : < 3,0 VDC
Précision : ± (1 % + 0,0001 V)
Continuité
Seuil de tonalité : Entre 20 Ω et 200 Ω
Temps de réponse : < 100 µs
dBm
La plage et la fréquence dépendent de la fonction de tension AC utilisée et
de l'impédance de référence sélectionnée.
Impédance de référence sélectionnable : 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200,
250, 300, 500, 600, 800, 900, 1000, 1200 Ω
Saisie de crête (tension et intensité) pour crêtes de durée > 0,8 ms
Précision : Précision indiquée + 100 chiffres
Résolution 5000 chiffres
72
Caractéristiques techniques
Affichage : cristaux liquides (LCD)
Mode normal : 50 000 points
Mode haute résolution : 500 000 points
Fréquence : 99 999 points
Graphique à barres 41 segments
Polarité : automatique
Impédance d’entrée : 10 MΩ, 60 pF nominal (80 pF pour les calibres de 500 mV).
Fréquence d’échantillonnage :
Mode 50 000 points : 5 par seconde (nominal)
Mode 500 000 points : 1,25 par seconde (nominal)
Graphique à barres : 60 par seconde
Coefficient de température : nominal 0,15 x (précision) par °C en dessous de 18 °C de 0 °C à 18 °C
(32°F à 64 °F) ou au-dessus de 28 °C de 28 °C à 40 °C (82 °F à 104 °F) ou autrement indiqué
Mise hors tension automatique intelligente : au bout de 17 minutes d'inactivité
Indicateur de décharge des piles : en dessous de 7 V environ
Élimination du bruit* :
Taux d’élimination du mode normal > 60 dB à 50 Hz et 60 Hz lors de la mesure de tension continue
Taux d’élimination du mode commun > 90 dB de 0 Hz à 60 Hz lors de la mesure de
tensionalternative
Taux d’élimination du mode normal > 120 dB à 50 Hz et 60 Hz lors de la mesure de
tensioncontinue
Conditions d’utilisation :
0 °C à 31 °C (32 °F à 88 °F), 0 % à 80 % d’humidité relative
31 °C à 45 °C (88 °F à 113 °F), l'humidité relative décroît linéairement de 80 % à 50 %
(sanscondensation)
Altitude : 2 000 m au maximum
Utilisation à l’intérieur uniquement
Degré de pollution : 2
Conditions d’entreposage : -20 °C à 60 °C (-4 °F à 140 °F), 0 % à 80 % d’humidité relative
(sanscondensation)
Enlever la pile
Pile : pile 9 V (NEDA 1604, JIS 006P ou IEC 6F)
C.E.M. : conforme à EN61326-1:2006
Dans un champ RF de 3 V/m :
Fonction de capacité non spécifiée
Autres fonctions : précision totale = précision indiquée + 1000 chiffres
Performances au-dessus de 3 V/m non spécifiées
* L'élimination du bruit est la capacité de rejeter des signaux indésirables, ou bruit.
• Les tensions de mode normal sont des signaux alternatifs pouvant fausser des mesures en
courant continu. Le TRMN (taux de réjection en mode normal) est une mesure de la capacité à
filtrer ces signaux.
• Les tensions de mode commun sont des signaux présents aux bornes d'entrée COM et +, par
rapport à la terre, pouvant provoquer des sautes ou un décalage de l'affichage des mesures de
tension. Le TRMC (taux de réjection en mode commun) est une mesure de la capacité à filtrer ces
signaux.
DM-860A
73
Caractéristiques techniques (suite)
Sécurité : Double isolation conformément à CEI/UL/EN61010-1 Éd. 3.0, CEI/EN61010-2-030 Éd. 1.0,
CEI/EN61010-2-033 Éd. 1.0, CEI/UL/EN61010-031 Éd. 1.1 et CAN/CSA-C22.2 No. 61010-1-12
Éd. 3.0 selon CAT IV 1 000 V CA/CC.
Protection contre les surcharges :
V : 1 100 V CC/CA rms
A : Fusible F, 11 A/1 000 V, valeur d’interruption nominale 20 kA, 13/32 po x 1,5 po
µA et mA : Fusible F, 0,44 A/1 000 V, valeur d’interruption nominale 10 kA, 13/32 po x 1-3/8 po.
mV, Ω et autres fonctions : 1 000 V CC/CA rms
DIRECTIVES CENELEC : Ces instruments sont conformes aux directives CENELEC 2006/95/CE, relative
à la basse tension, et 2004/108/CE, relative à la compatibilité électromagnétique
Catégories de mesure
Ces définitions sont dérivées des normes internationales sur la sécurité pour la coordination
de l’isolation telle qu’elle s’applique à la mesure, au contrôle et à l’équipement de laboratoire.
Ces catégories de mesure sont expliquées plus en détail par la Commission électrotechnique
internationale ; se reporter à l’une de ces deux publications : IEC 61010-1 ou IEC 60664.
Catégorie de mesure I
Niveau de signal. Pièces ou équipement électronique et de télécommunication. Par exemple, les
circuits électroniques protégés contre les courants transitoires, dans les photocopieurs et les modems.
Catégorie de mesure II
Niveau local. Appareils, équipement portatif et les circuits dans lesquels ils sont branchés. Par exemple,
les appareils d’éclairage, les téléviseurs et les dérivations.
Catégorie de mesure III
Niveau de distribution. Les machines installées en permanence et les circuits auxquels elles sont
câblées. Par exemple, les systèmes de convoyeurs et les panneaux de disjoncteurs principaux du
système électrique d’un édifice.
Catégorie de mesure IV
Niveau d’alimentation principal. Lignes surélevées et autres systèmes de câbles. Par exemple,
les câbles, les compteurs, les transformateurs et autres équipements extérieurs appartenant aux
fournisseurs en électricité.
Déclaration de conformité
Greenlee Tools, Inc. est certifiée selon ISO 9001:2008 pour nos Systèmes de gestion de la qualité.
L’instrument ci-inclus a été vérifié et/ou étalonné avec des moyens de mesure raccordés aux étalons
du National Institute of Standards and Technology (NIST).
74
Entretien
Risques de décharge électrique:
Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension.
L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles.
Risques de décharge électrique:
Les fusibles forment une partie intégrante du système de protection de surtension. Lorsqu’un fusible
doit être remplacé, consulter les caractéristiques techniques pour connaître le type, la taille et la
capacité requis. L’utilisation de tout autre type de fusible annule l’étalonnage de protection contre la
surtension de l’appareil.
L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles.
Changer la pile
1. Débrancher l’appareil du circuit. Mettre l’appareil hors
tension (OFF).
2. Ôter les deux vis du couvercle d’accès à la pile et
enlever le couvercle.
3. Changer la pile en veillant à respecter la polarité.
Changer les fusibles
1. Débrancher l’appareil du circuit. Mettre l’appareil hors
tension (OFF).
2. Ôter les deux vis du couvercle d’accès à la pile et
enlever le couvercle.
3. Dévisser les deux vis à l’intérieur du compartiment de
pile et les deux vis au dos du boîtier.
4. Enlever le dos du boîtier et changer les fusibles.
5. Aligner les deux moitiés de l’appareil et les joints en caoutchouc.
6. S’assurer que le sélecteur est dans sa position d’origine afin de s’aligner correctement avec le
commutateur interne.
7. Remettre le couvercle et les vis en place.
Nettoyage et entreposage
Nettoyer régulièrement le boîtier avec un chiffon humide et un détergent doux. Ne pas utiliser de
produits abrasifs ou de solvants.
Si le multimètre doit rester inutilisé pendant des durées de plus de 60 jours, sortir la pile et l’entreposer
séparément.
DM-860A
75
Lifetime Limited Warranty
Greenlee Tools, Inc. warrants to the original purchaser of these goods for use that these products will
be free from defects in workmanship and material for their useful life, excepting normal wear and
abuse. This warranty is subject to the same terms and conditions contained in Greenlee Tools, Inc.’s
standard one-year limited warranty.
For all Test Instrument repairs, contact Customer Service at 800-435-0786 and request a Return
Authorization.
For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote is
available upon request.
Note: Prior to returning any test instrument, please check replaceable batteries or make sure the
battery is at full charge.
Garantía limitada válida durante la vida útil del producto
Greenlee Tools, Inc. le garantiza al comprador original de estos bienes de uso, que los mismos estarán
libres de defectos de materiales y fabricación durante su vida útil, excepto en el caso de que sean
maltratados o hayan sufrido el deterioro normal. Esta garantía está sujeta a los mismos términos y
condiciones de la garantía estándar limitada válida por un año, otorgada por Greenlee Tools, Inc.
Para reparaciones de todo instrumento de verificación, comuníquese con el Departamento de Servicio
al Cliente al 800-435-0786 y solicite una autorización de devolución.
Puede obtener, previa solicitud, una cotización de precios de reparación para aquellos artículos que no
están cubiertos bajo esta garantía (los que se han dejado caer o han sido maltratados).
Aviso: Antes de devolver un instrumento de verificación, revise si las baterías están bajas y es
necesario reemplazarlas.
Garantie à vie limitée
La société Greenlee Tools, Inc. garantit à l’acheteur d’origine de ces produits que ces derniers ne
comportent aucun défaut d’exécution ou de matériau pour la durée de leur vie utile, sauf l’usure
normale. Cette garantie est assujettie aux mêmes conditions que celles contenues dans les modalités
et conditions de la garantie limitée standard d’un an de Greenlee Tools, Inc.
Pour toutes les réparations d’instruments de mesure, appeler le service après vente au
800 435-0786 et demander une autorisation de retour.
Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil tombe, s’il est soumis à
un usage abusif, etc.), une soumission pour le prix de réparation sera présentée sur demande.
Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier les piles remplaçables ou vous
assurer que la batterie est complètement chargée.
4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070
An ISO 9001 Company • ©2019 Greenlee Tools, Inc.
USA
Tel: 800-435-0786
Fax: 800-451-2632
Canada
Tel: 800-435-0786
Fax: 800-524-2853
International
Tel: +1-815-397-7070
Fax: +1-815-397-9247
www.greenlee.com

Transcripción de documentos

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D’INSTRUCTIONS DM-860A Digital Multimeter Multímetro digital Multimètre numérique Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Lea y entienda todas las instrucciones y la información sobre seguridad que aparecen en este manual, antes de manejar estas herramientas o darles mantenimiento. Lire attentivement et bien comprendre toutes les i­nstructions et les informations sur la sécurité de ce manuel avant d’utiliser ou de procéder à l’entretien de cet outil. Register this product at www.greenlee.com / Registre este producto en www.greenlee.com Enregistrez votre produit en ligne, www.greenlee.com 52056270 REV 2 © 2019 Greenlee Tools, Inc. 9/19 Description The Greenlee DM-860A Digital Multimeter is a hand-held testing device with the following measurement capabilities: AC and DC voltage, AC and DC current, percent of loop current, two channels of temperature (K-type thermocouples), frequency, duty cycle, resistance, conductance, and capacitance. It also checks diodes and verifies continuity. The DM-860A features a bar graph display that responds more quickly than the numeric display—­ useful for detecting faulty contacts, potentiometer clicks, and signal spikes. An optional optically isolated ­computer interface with software facilitates the recording of readings from the meter to a computer. Other specialized functions and capabilities include: • Dual display shows two measurements, such as AC voltage and frequency, at the same time. • Beep-Jack™ audible warning alerts the user with a beep and an error message on the LCD if the test lead is plugged into the mA µA or A input terminal while the selector switch is not in the mA µA or A position. • AC bandwidth to 100 kHz for voltage or 20 kHz for current. • MAX/MIN function which stores the maximum, minimum, and average. • Crest capture mode to capture voltage or current signal peaks. • Selectable between 50,000 or 500,000 counts resolution when measuring DC voltage. • Relative zero mode. • Automatic or manual ranging. • Intelligent automatic power off. • Backlighted LCD for reading in dim conditions. Safety Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool. Observe all of the safety information provided. Purpose of This Manual This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee DM-860A Digital Multimeter. Keep this manual available to all personnel. Replacement manuals are available upon request at no charge at www.greenlee.com. Do not discard this product or throw away! For recycling information, go to www.greenlee.com. 2 DM-860A Important Safety Information SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message after the signal word provides information for preventing or avoiding the hazard. Immediate hazards which, if not avoided, WILL result in severe injury or death. Hazards which, if not avoided, COULD result in severe injury or death. Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage. Read and understand this material before operating or servicing this ­equipment. Failure to understand how to safely operate this tool could result in an accident causing serious injury or death. Electric shock hazard: Contact with live circuits could result in severe injury or death. All specifications are nominal and may change as design improvements occur. Greenlee Tools, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. ® Registered: The color green for electrical test instruments is a registered trademark of Greenlee Tools, Inc. Beep-Jack is a trademark of BTC. Microsoft and Windows are registered trademarks of Microsoft Corporation. KEEP THIS MANUAL 3 Important Safety Information Electric shock and fire hazard: • Do not expose this unit to rain or moisture. • Do not use the unit if it is wet or damaged. • Only use the test leads provided with the equipment or UL Listed Probe Assembly with same rating or better. • Inspect the test leads or accessory before use. They must be clean and dry, and the insulation must be in good condition. Do not use the test lead if the contrasting inner layer of insulation is visible. • Use this unit for the manufacturer’s intended purpose only, as described in this manual. Any other use can impair the protection provided by the unit. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: • Do not apply more than the rated voltage between any two input terminals, or between any input terminal and earth ground. • Do not contact the test lead tips or any uninsulated portion of the accessory. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: • Do not operate with the case open. • Before opening the case, remove the test leads from the circuit and shut off the unit. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: The fuses are an integral part of the overvoltage protection. When fuse replacement is necessary, refer to “Specifications” for the correct type, size, and capacity. Using any other type of fuse will void the overvoltage protection rating of the unit. Failure to observe this warning could result in severe injury or death. 4 DM-860A Important Safety Information Electric shock hazard: • Unless measuring voltage, current, or frequency, shut off and lock out power. Make sure that all capacitors are discharged. Voltage must not be present. • Set the selector and connect the test leads so that they correspond to the intended measurement. Incorrect settings or connections can result in a blown fuse. • Using this unit near equipment that generates electromagnetic interference can result in unstable or inaccurate readings. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: Do not change the measurement function while the test leads are connected to a component or circuit. Failure to observe this precaution may result in injury and can damage the unit. Electric shock hazard: • Do not attempt to repair this unit. It contains no user-serviceable parts. • Do not expose the unit to extremes in temperature or high humidity. Refer to “Specifications.” Failure to observe these precautions may result in injury and can damage the unit. 5 Identification 1. 2. 3. 4. Display Feature Buttons Selector A 5. mA µA 6. COM 7. ΩV LCD and bar graph Refer to explanations under “Using the Features” Selects a function or turns power OFF Positive input terminal for high current measurements; negative input terminal for T2 Positive input terminal for low current measurements; positive input terminal for T2 Negative, common, or ground input terminal for all measurements Positive input terminal for all measurements except current 1 2 3 4 7 5 Symbols on the Unit Warning—Read the instruction manual Double insulation 6 6 DM-860A Display Icons Primary Display 8. 9. – 10. 11. ∆ 12. VFD 13. – 14. 8.8.8.8.88 15. T1-T2 16. 17. 18. MAX 19. MIN 20. AVG 21. 22. 23. 24. 25. 26. 27. } 28. 5 29. D% 30. k Bar graph element Polarity indicator for bar graph Bar graph scale Relative zero function is enabled. VFD function is enabled. Polarity indicator Numeric display T1, T2, or T1-T2 function is enabled. AC measurement is selected. DC measurement is selected. Maximum value being recorded or displayed. Minimum value being recorded or displayed. Average value being recorded or displayed. Record function is enabled. Crest capture function is enabled. Hold function is selected. Automatic ranging is enabled. Continuity Low battery Overload symbol (bar graph display) Bar graph maximum range indicator Duty cycle function is enabled. Kilo (103) 51-53 25 26 24 21-23 18-20 16-17 15 13-14 12 11 10 8-9 31. M 32. Ω 33. Hz 34. dBm 35. m 36. µ 37. V 38. A 39. n 40. F 41. S Mega (106) Ohm Hertz (frequency in cycles per second) Decibel Milli (10-3) Micro (10-6) Volt Ampere Nano (10-9) Farad Siemen Secondary Display 42. %4-20mA Industrial process control loop current function is enabled. 43. µ Micro (10-6) 44. m Milli (10-3) 45. A Ampere 46. V Volt 47. M Mega (106) 48. k Kilo (103) 49. Hz Hertz (frequency in cycles per second) 50. 8.8.8.8 Numeric display 51. T2 T2 function is enabled. 52. AC measurement is selected. 53. – Polarity indicator 50 47-49 43-46 42 29-41 28 27 7 Using the Features • Dual Digital Display: This meter can display two measurements, such as AC voltage and frequency, at the same time. Display combinations are shown using large symbols to indicate the measurement on the primary display and small, raised symbols to indicate the measurement on the secondary display. For example, “VACHz” means the primary display contains the AC voltage measurement, and the secondary display contains the frequency measurement. • VFD ~V and VFD Hz: These functions use filtering and noise-rejection algorithms to make accurate voltage and frequency measurements on most variable frequency drives. The voltage measurement automatically selects the 500 volt range. Use the RANGE button to select other ranges only when needed. The sensitivity for VFD frequency measurements depends on voltage range and input frequency. Refer to “Frequency – Line Level” in the “Accuracy” section of this manual. • SELECT: Press momentarily to toggle between functions, measurement modes, or display modes. The last used setting becomes the default when that function is selected again. To change the default, select a new setting. The setting will be stored in nonvolatile memory. • RANGE: Press once to enter the manual ranging mode. The icon will disappear from the display. Press repeatedly to step through the ranges. Press and hold to return to the automatic ranging mode. Note: When using CREST, REC, HOLD, or ∆ mode, pressing RANGE will cause the meter to exit that mode. • ∆: Finds the difference between two measurements. While taking a measurement, press ∆ to set the display to zero. The ∆ icon will appear on the display. Take the second measurement. The value on the display will be the difference between the two measurements. Press again to exit this mode. This feature applies to the main display only. • HOLD : Press momentarily to hold the present value on the display. Press again to exit this mode. This feature does not affect the bar graph. • CREST : Press momentarily to activate the crest recording mode.The input value is measured every 1 ms in this mode. and “MAX” will appear on the display. The LCD will display the maximum crest value. The meter will beep whenever the maximum or minimum is updated. Press repeatedly to select the desired display: maximum or minimum crest value. Press and hold to exit this mode. The automatic power off feature is disabled when using this function. Note: When using the CREST function, pressing RANGE will cause the meter to exit this mode. • REC : Press momentarily to activate the MAX/MIN/AVG recording mode. The input value is measured every 50 ms in this mode. “MAX MIN” and “AVG” will appear on the display. The LCD will display the actual input value. The meter will beep whenever the maximum or minimum is updated. Press repeatedly to select the desired display: maximum, minimum, average, or actual input. Press and hold to exit this mode. The automatic power off feature is disabled when using this function. Note: When using the REC function, pressing RANGE will cause the meter to exit this mode. • : Press and hold until backlight illuminates. Press and hold again to turn off. The backlight automatically turns off after approximately 30 seconds to extend battery life. 8 DM-860A Using the Features (cont’d) • dBm-Ω: The reference impedance is displayed for 1 second after selecting the dBm function. Momentarily press dBm-Ω to change the reference impedance. Refer to the “Specifications” section for the available values. Note: This is an AC voltage measurement calculated according to the formula        dBm = 20 x log (measured voltage / reference voltage The reference voltage is the voltage that causes 1 mW of power to be dissipated in the selected reference impedance. • T1-T2: Press momentarily to select the desired temperature display: T1, T2, T1T2, or T1-T2T2. • 500000: Press and hold to toggle between 50,000 counts fast mode and the 500,000 counts high resolution mode for DC voltage measurements. • Intelligent Automatic Power Off (APO): To extend battery life, the meter shuts itself off after approximately 17 minutes of inactivity. Inactivity occurs when buttons are not pressed or the selector is not turned. The meter will not enter APO when there are significant readings of over 10% of the range or non-OL readings for resistance and continuity. To restore power, press SELECT, RANGE, ∆, or HOLD or turn the selector to OFF and back on again. To disable this feature, press SELECT while turning the meter on. • Disabling the Beeper: Hold down the RANGE button while turning the meter on to temporarily disable the beeper feature. Turn the selector to OFF and then back on to enable the beeper. • Hz: Frequency can be measured in most voltage and current settings of the selector. Press SELECT until “Hz” appears in the primary or secondary display, as desired. The sensitivity of the Line Level Frequency function varies with measurement range. Refer to “Specifications.” Auto-ranging measurements usually set the best trigger level. If the frequency reading becomes unstable or is blank, press the RANGE button to select another trigger level. • %4-20mA: This calculated value is one of three available options for the secondary display when measuring DC milliamps. It is useful for 4-20 mA industrial process control loop applications. A reading of 4 mA on the primary display gives a 0% reading on the secondary display, 12 mA gives 50%, 20 mA gives 100%, etc. 9 AC Measurement AC measurements are usually displayed as RMS (root mean square) values. The RMS value is equal to the value of a DC waveform, which would deliver the same power if it replaced the time-varying waveform. Two AC measurement methods are average-responding RMS calibrated and true RMS-reading. The average-responding RMS calibrated method takes the average value of the input signal after full wave rectification, multiplies it by 1.11, and displays the result. This method is accurate if the input signal is a pure sine wave. The true RMS-reading method uses internal circuitry to read the true RMS value. This method is accurate, within the specified crest factor limitations, whether the input signal is a pure sine wave, square wave, triangle wave, half wave, or signal with harmonics. The ability to read true RMS provides much more measurement versatility. The Greenlee DM-860A is a true RMS meter. The Waveforms and Crest Factors table shows some typical AC signals and their RMS values. Waveforms and Crest Factors Waveform RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor* (x) 1.414 1 1.73 2 * The crest factor is the ratio of the peak value to the RMS value; it is represented by the Greek letter x. AC + DC True RMS AC + DC true RMS calculates both of the AC and DC components given by the expression when making measurements and responds accurately to the total effective RMS value regardless of the waveform. Distorted waveforms with the presence of DC components and harmonics may cause: • Transformers, generators, and motors to overheat • Circuit breakers to trip prematurely • Fuses to blow • Neutrals to overheat due to the triplen harmonics present on the neutral • Bus bars and electrical panels to vibrate 10 DM-860A AC Bandwith AC bandwidth of a digital multimeter (DMM) is the range of frequencies over which AC measurements can be made within the specified accuracy. It is the frequency response of the AC functions—not of the frequency measurement functions. A DMM cannot accurately measure the AC value with frequency spectrums beyond the AC bandwidth of the DMM. Therefore, wide AC bandwidth plays an important role in high performance DMMs. Complex waveforms, noise, and distorted waveforms contain frequency components that are much higher than the fundamental; for example, high frequency noise on a 50/60 Hz power line. Operation Electric shock hazard: Contact with live circuits could result in severe injury or death. Self-Diagnostic Mode The message “rE-O” may appear when the meter is turned on. This indicates that the meter is performing a routine self-diagnostic. Do not turn the meter off. Allow the diagnostic procedure to finish. If the message “C_Er” appears on the display when the meter is turned on, some ranges may be well outside of specification. To avoid incorrect measurements, stop using the meter and return it to Greenlee for recalibration. Operating Procedure 1. Refer to the Settings Table. Set the selector to the proper setting, press SELECT (when instructed to do so), and connect the test leads to the meter. 2. Refer to “Typical Measurements” for specific measurement instructions. 3. Test the unit on a known functioning circuit or component. • If the unit does not function as expected on a known functioning circuit, replace the battery and/ or fuses. • If the unit still does not function as expected, call Greenlee for technical assistance at 800-435-0786. 4. Take the reading from the circuit or component to be tested. 11 Operation (cont’d) Settings Table The meter stores the last used function of each selector position in its nonvolatile memory. If this is not the correct function when you turn the selector, press SELECT until the desired icon appears. The dual display options are shown along with the icons. In the table, “~VHz” indicates that “~” and “V” appear in the primary display, and “Hz” appears in the secondary display. This combination shows the AC voltage measurement in the primary display and frequency in the secondary display. To measure this characteristic … Press SELECT until Connect Connect the Set the selector to these icons appear on the red black lead this symbol … the display … lead to … to … Variable Speed Drive— Voltage and Frequency Voltage—AC True RMS (1000 V max) *Voltage—DC (1000 V max) Voltage—AC + DC True RMS (1000 V max) Voltage—DC (500 mV max) Voltage—AC + DC True RMS (500 mV max) Voltage—AC True RMS (500 V max) Frequency—Line Level Voltage or Current **Frequency—Logic Level VHz or Hz~V ΩV COM VHz or Hz~V ΩV COM ΩV COM ΩV COM ΩV COM mV~mV ΩV COM mVHz or Hz~mV ΩV COM V~V V or V~V mV or Set for voltage or current according to this table. Hz mV~mV Any display option that includes Hz ­— — Hz ΩV COM % Duty Cycle D% D% ΩV COM dBm (0 dB = 1 mW in reference impedance) dBm ( function 1000 V max; function 500 mV max.) Reference impedance and dBm for 1 s, then dBmHz (press dBm-Ω to change reference impedance) ΩV COM * For precise measurements, press 500000 to toggle between 50,000 counts and 500,000 counts. Applies to DC volts only. ** Logic level frequency has a fixed sensitivity and is for digital signals. Refer to “Accuracy”. This table continues on the next page. 12 DM-860A Operation (cont’d) Settings Table (cont’d) To measure this characteristic … Dual Temperature Press SELECT until Connect Connect the Set the selector to these icons appear on the red black lead this symbol … the display … lead to … to … °C or °F (press RANGE See Notes T1T2 for display options T1, — 1 and 2 T2 T2 T2, T1 or T1-T2 ) †Capacitance F ΩV COM Diode V and diod ΩV COM Ω ΩV COM and Ω ΩV COM nS ΩV COM Resistance Ω Continuity Conductance nS Current—AC, DC, or AC + DC True RMS (10 A max) A A, A~A, A~A, or AHz A COM Current—AC, DC, or AC + DC True RMS (600 mA max) mA mA%4-20mA, mA~mA, mA~mA, or mAHz mA µA COM Current—AC, DC, or AC + DC True RMS (6000 µA max) µA µA~µA, µA~µA, or µAHz mA µA COM Industrial Process Control Loop Current % 4 to 20 mA mA mA%4-20mA mA µA COM µA, † Discharge capacitor before measurement. Refer to “Typical Measurements” regarding polarized capacitors. Note 1: T1+ connects to ΩV , and T1– connects to COM. Note 2: T2+ connects to mA µA, and T2– connects to A. 13 Typical Measurements Voltage Measurement Current Measurement 14 DM-860A Typical Measurements Resistance Measurement Continuity Check Capacitance Measurement Diode Measurement Reverse Bias Forward Bias Note: For polarized capacitors, attach red probe to positive terminal and black probe to negative terminal of capacitor. 15 Typical Measurements Temperature 16 DM-860A Using the Optional Software The DM-860A is compatible with Greenlee DMSC-9U, an optically isolated computer interface cable and software. It allows measurements to be logged to a personal computer using the Microsoft® Windows® operating system. Installing the Software 1. Insert the CD into the computer’s CDROM drive. 2. The installation program should launch automatically. If it does not, double click on the CD icon in “My Computer.” 3. The installation program menu will appear. Click on “Software Installation.” 4. Type your meter’s catalog number (for example, “DM-860A”) in the dialog box. 5. Complete the remaining dialog boxes according to user preferences. Connecting the Optical USB Interface Cable 1. Align the key of the connector with the key slot on the meter. 2. Twist the connector clockwise until it locks into place. 3. Connect the cable to a USB port of the PC. Key slot on back of meter 17 Accuracy Refer to the “Specifications” section for operating conditions and temperature coefficient. Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 75% relative humidity. Specifications are for 50,000 counts mode. True RMS Readings: Voltage and current accuracies are specified from 5% to 100% of the range unless otherwise specified. Frequency must be within the specified bandwidth for non-sinusoidal waveforms. Crest factors are as follows: • Crest factor < 2.1:1 at full scale • Crest factor < 4.2:1 at half scale AC, DCAC, and AC + DCAC Current Accuracy at DC and 50 Hz to 60 Hz 500.00 µA ± (0.5% + 0.5 µA) 5000.0 µA ± (0.5% + 5.0 µA) 50.000 mA ± (0.5% + 0.05 mA) 500.00 mA ± (0.5% + 0.5 mA) 5.0000 A ± (0.5% + 0.005 A) 10.000 A* ± (0.5% + 0.05 A) Range   * 10 A Accuracy at 40 Hz to 1 kHz ± (0.7% + 0.5 µA) ± (0.7% + 5.0 µA) ± (0.7% + 0.05 mA) ± (0.7% + 0.5 mA) ± (0.7% + 0.005 A) ± (0.7% + 0.05 A) Accuracy at 1 kHz to 20 kHz ± (2.0% + 0.5 µA) ± (2.0% + 5.0 µA) ± (2.0% + 0.05 mA) ± (2.0% + 0.5 mA) Unspecified Unspecified continuous; 20 A maximum (Duty Cycle: 30 seconds on, 5 minutes off). Range 500.00 µA 5000.0 µA 50.000 mA 500.00 mA 5.0000 A 10.000 A Burden Voltage (all frequency ranges) 0.15 mV/µA 3.3 mV/mA 45 mV/A DC Current Range 500.00 µA 5000.0 µA 50.000 mA 500.00 mA 5.0000 A 10.000 A*   * 10 A 18 Accuracy ± (0.15% + 0.2 µA) ± (0.1% + 2.0 µA) ± (0.15% + 0.02 mA) ± (0.15% + 0.3 mA) ± (0.5% + 0.002 A) ± (0.5% + 0.02 A) Burden Voltage 0.15 mV/µA 3.3 mV/mA 45 mV/A continuous; 20 A maximum (Duty Cycle: 30 seconds on, 5 minutes off). Accuracy at 20 kHz to 100 kHz ± (5.0% + 0.5 µA) ± (5.0% + 5.0 µA) ± (5.0% + 0.05 mA) ± (5.0% + 0.5 mA) Unspecified Unspecified DM-860A Accuracy (cont’d) DCAC and AC + DCAC Voltage Accuracy* at 20 Hz to 45 Hz 500.00 mV ± (1.5% + 0.4 mV) 5.0000 V ± (1.5% + 0.004 V) 50.000 V ± (1.5% + 0.04 V) 500.00 V Unspecified 1000.0 V Unspecified Range Accuracy* at DC Accuracy* at and 45 Hz to 1 kHz 1 kHz to 20 kHz ± (0.5% + 0.4 mV) ± (1.0% + 0.4 mV) ± (0.5% + 0.008 V) ± (1.2% + 0.004 V) ± (0.5% + 0.08 V) ± (1.2% + 0.04 V) ± (0.5% + 0.8 V) Unspecified ± (0.5% + 8 V) Unspecified Accuracy* at 20 kHz to 40 kHz ± (3.5% + 0.4 mV)** ± (4.0% + 0.004 V)** ± (4.0% + 0.04 V)** Unspecified Unspecified   * From 5% to 10% of range: Accuracy percentage of reading + 80 digits. 5% to 10% of range: Accuracy percentage of reading + 180 digits. From 10% to 15% of range: Accuracy percentage of reading + 100 digits. Residual reading less than 50 digits with test leads shorted. Note: “Digits” refers to the least significant digit (the number in the right-most position). ** From VFD AC Voltage Range 5.0000 V 50.000 V 500.00 V 1000.0 V Accuracy* at 5 Hz to 20 Hz ± (3% + 0.008 V) ± (3% + 0.08 V) ± (3% + 0.8 V) ± (3% + 8 V) Accuracy* at 20 Hz to 200 Hz ± (2% + 0.005 V) ± (2% + 0.05 V) ± (2% + 0.5 V) ± (2% + 5 V) Accuracy* at 200 Hz to 440 Hz ± (6% + 0.008 V)** ± (6% + 0.08 V)** ± (6% + 0.8 V)** ± (6% + 8 V)**   * Not specified for fundamental frequency greater than 440 Hz. **Accuracy decreases linearly from ± (2.0% + 50 digits) at 200 Hz to ± (6% + 80 digits) at 440 Hz. 19 Accuracy (cont’d) AC Voltage Range 500.00 mV 5.0000 V 50.000 V 500.00 V 1000.0 V Range 500.00 mV 5.0000 V 50.000 V 500.00 V 1000.0 V Accuracy* at 20 Hz to 45 Hz ± (1.2% + 0.4 mV) ± (1.2% + 0.004 V) ± (1.2% + 0.04 V) Unspecified Unspecified Accuracy* at 45 Hz to 65 Hz ± (0.3% + 0.2 mV) ± (0.3% + 0.003 V) ± (0.3% + 0.03 V) ± (0.5% + 0.3 V) ± (0.5% + 3 V) Accuracy* at 10 kHz to 20 kHz ± (0.5% + 0.3 mV) ± (0.7% + 0.004 V) ± (0.7% + 0.04 V) ± (0.7% + 0.4 V) Unspecified Accuracy* at 20 kHz to 100 kHz ± (2.5% + 0.4 mV)** ± (3.5% + 0.004 V)** ± (3.5% + 0.04 V)** Unspecified Unspecified   * From Accuracy* at 65 Hz to 10 kHz ± (0.4% + 0.25 mV) ± (0.3% + 0.004 V) ± (0.3% + 0.04 V) ± (0.5% + 0.4 V) ± (0.8% + 4 V) (65 Hz to 1 kHz) 5% to 10% of range: Accuracy percentage of reading + 80 digits. 5% to 10% of range: Accuracy percentage of reading + 180 digits. Residual reading less than 50 digits with test leads shorted. Note: “Digits” refers to the least significant digit (the number in the right-most position). ** From DC Voltage Range 500.00 mV 5.0000 V 50.000 V 500.00 V 1000.0 V 20 Accuracy ± (0.02% + 0.02 mV) ± (0.02% + 0.0002 V) ± (0.03% + 0.002 V) ± (0.04% + 0.02 V) ± (0.15% + 0.2 V) Input Impedance 10 MΩ, 80 pF nominal 10 MΩ, 60 pF nominal DM-860A Accuracy (cont’d) Resistance and Conductance * Range Accuracy 500.00 Ω 5.0000 kΩ 50.000 kΩ 500.00 kΩ 5.0000 MΩ 50.000 MΩ 99.99 nS ± (0.07% + 0.10 Ω) ± (0.07% + 0.0002 kΩ) ± (0.1% + 0.002 kΩ) ± (0.1% + 0.02 kΩ) ± (0.3% + 0.0006 MΩ) ± (2.0% + 0.006 MΩ) ± (0.8% + 0.10 nS)* Typical Open Circuit Voltage 3.0 VDC 1.3 VDC ± (2.0% + 0.40 nS) below 9.99 nS. Capacitance Range 50.00 nF 500.0 nF 5.000 µF 50.00 µF 500.0 µF** 5.000 mF** 25.00 mF** Accuracy* ± (0.8% + 0.03 nF) ± (0.8% + 0.3 nF) ± (1.5% + 0.003 µF) ± (2.5% + 0.03 µF) ± (3.5% + 0.5 µF) ± (5.0% + 0.005 mF) ± (6.5% + 0.05 mF)   * Accuracies are for film capacitors (capacitors with negligible dielectric absorption). ** In manual ranging mode, the 500.0 µF, 5.000 mF, and 25.00 mF ranges are not specified below 45.0 µF, 0.450 mF, and 4.50 mF, respectively. T1, T2, T1-T2 Dual Temperature Range –50 °C to 1000.0 °C –58 °F to 1832.0 °F   * Thermocouple not included. Accuracy* ± (0.3% + 1.5 °C) ± (0.3% + 3.0 °F) range and accuracy 21 Accuracy (cont’d) Frequency—Line Level Range: 5.000 Hz to 200.00 kHz Accuracy: ± (0.02% + 4 digits) AC Function Range 500 mV 5V 50 V 500 V 1000 V VFD 5 V VFD 50 V VFD 500 V Sensitivity (Sine RMS) 100 mV 0.5 V 5V 50 V 500 V 0.5 V to 2 V* 5 V to 20 V* 50 V to 200 V* Range 10 Hz to 200 kHz 10 Hz to 100 kHz 10 Hz to 10 kHz 10 Hz to 440 Hz AC Function Range 500 µA 5000 µA 50 mA 500 mA 5A 10 A Sensitivity (Sine RMS) 50 µA 500 µA 5 mA 50 mA 1A 10 A Range 10 Hz to 10 kHz 10 Hz to 3 kHz   * VFD sensitivity linearly decreases from 10% of range @ 200 Hz to 40% of range @ 440 Hz. Frequency­—Logic Level Range: 5.000 Hz to 2.0000 MHz Accuracy: ± (0.002% + 4 digits) Sensitivity: 2.5 Vp square wave % Duty Cycle Range: 0.1% to 99.99% Accuracy: ± (3 digits/kHz + 2 digits) Input Frequency: 5 Hz to 500 kHz, 5 V logic family Diode Test Measuring Range: 2.0000 V Test Current (typical): 0.4 mA Open Circuit Voltage: < 3.0 VDC Accuracy: ± (1% + 0.0001 V) Continuity Tone Threshold: Between 20 Ω and 200 Ω Response Time: < 100 µs dBm The range and accuracy depend on the AC voltage function used and the selected reference impedance. Selectable Reference Impedance: 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200 Ω Crest Capture (Voltage and Current) for Crests > 0.8 ms in duration Accuracy: Specified accuracy ± 100 digits Resolution: 5000 digits 22 DM-860A Specifications Display: LCD Normal Mode: 50,000 counts High Resolution Mode: 500,000 counts Frequency: 99,999 counts 41-segment bar graph Polarity: Automatic Input Impedance: 10 MΩ, 60 pF nominal (80 pF for 500 mV ranges). Sampling Rate: 50,000 Counts Mode: 5 per second nominal 500,000 Counts Mode: 1.25 per second nominal Bar Graph Display: 60 per second Temperature Coefficient: Nominal 0.15 x (Accuracy) per °C below 18 °C from 0 °C to 18 °C (32 °F to 64 °F) or above 28 °C from 28 °C to 40 °C (82 °F to 104 °F) or otherwise specified Intelligent Automatic Power Off: After 17 minutes of inactivity Low Battery Indication: Below approximately 7 V Noise Rejection*: Normal Mode Rejection Ratio > 60 dB at 50 Hz and 60 Hz when measuring DCV Common Mode Rejection Ratio > 90 dB from 0 Hz to 60 Hz when measuring ACV Common Mode Rejection Ratio > 120 dB at 50 Hz and 60 Hz when measuring DCV Operating Conditions: 0 °C to 31 °C (32 °F to 88 °F), 0% to 80% relative humidity 31 °C to 45 °C (88 °F to 113 °F), relative humidity decreasing linearly from 80% to 50% (non-condensing) Altitude: 2000 m (6500') maximum Indoor use only Pollution Degree: 2 Storage Conditions: –20 °C to 60 °C (–4 °F to 140 °F), 0% to 80% relative humidity (non-condensing) Remove battery Battery: 9 V battery (NEDA 1604, JIS 006P or IEC 6F) E.M.C.: Meets EN61326-1:2006 In an RF field of 3 V/m: Capacitance function is not specified Other function ranges: Total Accuracy = Specified Accuracy + 1000 digits Performance above 3 V/m is not specified * Noise rejection is the ability to reject unwanted signals, or noise. • Normal mode voltages are AC signals that can cause inaccurate DC measurements. NMRR (Normal Mode Rejection Ratio) is a measure of the ability to filter out these signals. • Common mode voltages are signals present at the COM and + input terminals, with respect to ground, that can cause digit rattle or offset in voltage measurements. CMRR (Common Mode Rejection Ratio) is a measure of the ability to filter out these signals. 23 Specifications (cont’d) Safety: Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to Category IV 1000 V AC/DC. Overload Protections: V: 1100 V DC/AC rms A: 11 A/1000 V fuse, interrupting rating 20 kA, F fuse, 13/32" x 1-1/2" µA and mA: 0.44 A/1000 V fuse, interrupting rating 10 kA, F fuse, 13/32" x 1-3/8" mV, Ω, and Other Functions: 1000 V DC/AC rms CENELEC DIRECTIVES: The instruments conform to CENELEC Low-voltage directive 2006/95/EC and Electromagnetic compatibility directive 2004/108/EC Measurement Categories These definitions were derived from the international safety standard for insulation c­ oordination as it applies to measurement, control, and laboratory equipment. These measurement categories are explained in more detail by the International Electrotechnical Commission; refer to either of their ­publications: IEC 61010-1 or IEC 60664. Measurement Category I Signal level. Electronic and telecommunication equipment, or parts thereof. Some examples include transient-protected electronic circuits inside photocopiers and modems. Measurement Category II Local level. Appliances, portable equipment, and the circuits they are plugged into. Some examples include light fixtures, televisions, and long branch circuits. Measurement Category III Distribution level. Permanently installed machines and the circuits they are hard-wired to. Some examples include conveyor systems and the main circuit breaker panels of a building’s electrical system. Measurement Category IV Primary supply level. Overhead lines and other cable systems. Some examples include cables, meters, transformers, and other exterior equipment owned by the power utility. Statement of Conformity Greenlee Tools, Inc. is certified in accordance with ISO 9001:2008 for our Quality Management Systems. The instrument enclosed has been checked and/or calibrated using equipment that is traceable to the National Institute for Standards and Technology (NIST). 24 DM-860A Maintenance Electric shock hazard: Before opening the case, remove the test leads from the circuit and shut off the unit. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: The fuses are an integral part of the overvoltage protection. When fuse replacement is necessary, refer to “Specifications” for the correct type, size, and capacity. Using any other type of fuse will void the overvoltage protection rating of the unit. Failure to observe this warning could result in severe injury or death. Replacing the Battery 1. Disconnect the unit from the circuit. Turn the unit OFF. 2. Remove the two screws from the battery access door and remove it. 3. Replace the battery making sure to observe the polarity. Replacing the Fuses 1. Disconnect the unit from the circuit. Turn the unit OFF. 2. Remove the two screws from the battery access door and remove it. 3. Unscrew the two screws inside the battery compartment and the two screws on the back case. 4. Remove the back cover and replace the fuses. 5. Align the two halves of the unit and the rubber gaskets. 6. Be sure the selector is in the original position so that it lines up properly with the internal switch. 7. Replace the cover and screws. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter will not to be used for periods longer than 60 days, remove the battery and store it separately. 25 26 DM-860A Descripción El multímetro digital DM-860A de Greenlee es un dispositivo manual de pruebas que posee las siguientes capacidades de medición: Voltaje de CA y CC, corriente de CA y CC, porcentaje de corriente de bucle, dos canales de temperatura (termopares tipo K), frecuencia, ciclo de trabajo, resistencia, conductancia y capacitancia. También sirve para verificar diodos y continuidad.La unidad DM-860A cuenta con una pantalla de gráfico de barras, que responde más rápidamente que la pantalla numérica — útil para detectar fallas en contactos, potenciómetros y picos de señal. Una interfaz opcional de ordenador ópticamente aislada y software facilitan la grabación de lecturas del medidor a un ordenador. Otras de sus funciones y capacidades incluyen: • Pantalla doble que muestra simultáneamente dos mediciones, como el voltaje de CA y la frecuencia. • La función Beep-Jack™ que le advierte al usuario, mediante un tono audible y un mensaje de error en la pantalla LCD, si el cable de prueba se encuentra conectado a una terminal de entrada mA µA o A mientras el interruptor de selección no se encuentra en la posición mA µA o A. • Ancho de banda de CA a 100 kHz para voltaje o 20 kHz para corriente. • Función “MAX/MIN”, la cual guarda la señal máxima, mínima y la promedio. • Modo de captura de valor de cresta para capturar picos de señal de voltaje o corriente. • Seleccionable entre resolución de 50.000 ó 500.000 puntos al medir voltaje de corriente continua. • Modo de cero relativo. • Selección de escala manual o automática. • Apagado automático inteligente. • Pantalla de LCD con luz de fondo que facilita la lectura en condiciones de iluminación tenue. Acerca de la seguridad Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las herramientas y equipo Greenlee. Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la información necesaria para evitar riesgos y hábitos poco seguros relacionados con su uso. Siga toda la información sobre seguridad que se proporciona. Propósito de este manual Este manual de instrucciones tiene como propósito familiarizar a todo el personal con los procedimientos de operación y mantenimiento seguros para el Multímetro digital modelo DM-860A de Greenlee. Manténgalo siempre al alcance de todo el personal. Puede obtener copias adicionales de manera gratuita, previa solicitud en www.greenlee.com. ¡No deseche ni descarte este producto! Para información sobre reciclaje, visite www.greenlee.com. 27 Importante Información sobre Seguridad SÍMBOLO DE ALERTA SOBRE SEGURIDAD Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría ocasionar lesiones o daños materiales. Cada uno de los siguientes términos denota la gravedad del riesgo. El mensaje que sigue a dichos términos le indica cómo ­puede evitar o prevenir ese riesgo. Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso la muerte. Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la muerte. Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o daños materiales. Lea y entienda este documento antes de manejar esta herramienta o darle mantenimiento. Utilizarla sin comprender cómo manejarla de manera segura podría ocasionar un accidente, y como resultado de éste, graves lesiones o incluso la muerte. Peligro de electrocución: El contacto con circuitos activados podría ocasionar graves lesiones o incluso la muerte. Todas las especificaciones son nominales y pueden cambiar conforme tengan lugar mejoras de diseño. Greenlee Tools, Inc. no se hace responsable de los daños que puedan surgir de la mala aplicación o mal uso de sus productos. ® Registrado: El color verde para instrumentos de verificación eléctricos es una marca registrada de Greenlee Tools, Inc. Beep-Jack es una marca comercial de BTC. Microsoft y Windows son marcas comerciales registradas de Microsoft Corporation. 28 CONSERVE ESTE MANUAL DM-860A Importante Información sobre Seguridad Peligro de electrocución e incendio: • No exponga esta unidad ni a la lluvia ni a la humedad. • No utilice esta unidad si se encuentra mojada o dañada. • Utilice solo los conductores de prueba proporcionados con el equipo o un conjunto de sonda con certificación UL con una calificación igual o superior. • Revise minuciosamente los cables de prueba o el accesorio, antes de utilizarlos. Deberán estar limpios y secos, y su forro aislante deberá hallarse en buenas condiciones. No utilice el conductor de prueba si la capa interna de aislamiento en contraste resulta visible. • Utilícela únicamente para el propósito para el que ha sido diseñada por el fabricante, tal como se describe en este manual. Cualquier otro uso puede menoscabar la protección proporcionada por la unidad. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: • No aplique más del voltaje nominal entre dos terminales de entrada cualesquiera, o entre una terminal de entrada cualquiera y una conexión a tierra. • No toque las puntas de los cables de prueba ni ninguna parte del accesorio que carezca de forro aislante. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: • No haga funcionar esta unidad con la caja abierta. • Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: Los fusibles son una parte integral para la protección contra sobretensión. Cuando sea necesario reemplazarlos, consulte la sección “Especificaciones” para saber qué tipo, tamaño y capacidad deben tener. Utilizar cualquier otro tipo de fusible anulará la clasificación de protección de sobretensión de la unidad. De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte. 29 Importante Información sobre Seguridad Peligro de electrocución: • A menos que vaya a medir tensión, corriente o frecuencia, apague y bloquee la energía. Asegúrese de que todos los condensadores estén totalmente sin carga. No debe haber tensión alguna. • Coloque el interruptor de selección y conecte los cables de prueba de modo que correspondan al tipo de medición que se desea efectuar. Si se colocan o se conectan incorrectamente puede quemarse un fusible. • Al utilizar esta unidad cerca de equipo que genere interferencia electromagnética quizá se obtenga una lectura inexacta e inestable. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: No cambie la función de medición mientras los cables de prueba estén conectados a un componente o circuito. De no observarse esta precaución podrían sufrirse lesiones o daños a la unidad. Peligro de electrocución: • No intente reparar esta unidad, ya que contiene partes que deben recibir mantenimiento por parte de un profesional. • No exponga la unidad a ambientes de temperatura extrema o altos niveles de humedad. Consulte las Especificaciones. De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad. 30 DM-860A Identificación 1. Pantalla 2. Botones de funciones 3. Interruptor de selección 4. A 5. mA µA 6. COM 7. ΩV de cristal líquido (LCD) y gráfico de barras Consulte la explicación pertinente en la sección “Cómo utilizar las distintas funciones” Selecciona una función o apaga (OFF) la unidad Terminal de entrada positiva para mediciones de corriente alta; terminal de entrada negativa para T2 Terminal de entrada positiva para mediciones de corriente baja; terminal de entrada positiva para T2 Terminal de entrada a tierra, común o negativo, para todo tipo de mediciones Terminal de entrada positiva para todo tipo de mediciones excepto corriente 1 2 3 4 7 5 6 Símbolos en la unidad Advertencia — Lea el manual de instrucciones Doble forro aislante 31 Iconos de la pantalla Pantalla principal 33. Hz Hertzios (frecuencia en ciclos por segundo) Elemento de gráfico de barras 34. dBm Decibel Indicador de polaridad para 35. m Mili (10-3) el gráfico de barras 36. µ Micro (10-6) 10. Escala del gráfico de barras 37. V Voltio 11. ∆ Está activa la función de Cero relativo. 38. A Amperio 12. VFD Está activa la función VFD. 39. n Nano (10-9) 13. – Indicador de polaridad 40. F Faradio 14. 8.8.8.8.88 Pantalla numérica 41. S Siemen 15. T1-T2 Está activa la función T1, T2 o T1-T2. 16. Está seleccionada la medición de CA. Pantalla secundaria 17. Está seleccionada la medición de CC. 42. %4-20mA Se activa la función de corriente 18. MAX Valor máximo que se está grabando de bucle de control del o mostrando. proceso industrial. 19. MIN Valor mínimo que se está grabando 43. µ Micro (10-6) o mostrando. 44. m Mili (10-3) 20. AVG Valor promedio que se está grabando 45. A Amperio o mostrando. 46. V Voltio 21. Está activa la función Record (Grabar). 47. M Mega (106) 22. Está activa la función “Crest Capture” 48. k Kilo (103) (Captura de valor de cresta). 49. Hz Hertzios (frecuencia en 23. Está activa la función “Hold” ciclos por segundo) (retención de datos en pantalla). 50. 8.8.8.8 Pantalla numérica 24. Está activa la selección automática de escala. 51. T2 Está activa la función T2. 25. Continuidad 52. Está seleccionada la medición de CA. 26. Pila baja 53. – Indicador de polaridad 27. } Símbolo de sobrecarga (pantalla de gráfico de barras) 28. 5 Indicador de alcance máximo 51-53 en gráfico de barras 25 26 50 29. D% Está activa la función de ciclo 24 de operación. 47-49 21-23 30. k Kilo (103) 43-46 42 18-20 31. M Mega (106) 32. Ω Ohmios 8. 9. – 16-17 15 13-14 12 11 10 8-9 32 29-41 28 27 DM-860A Cómo utilizar las distintas funciones • Pantalla digital doble: Este medidor puede mostrar simultáneamente dos mediciones, como el voltaje de CA y la frecuencia. Las combinaciones de imagen en pantalla se muestran con símbolos grandes para indicar la medición en la pantalla primaria, y con símbolos pequeños y elevados para indicar la medición en la pantalla secundaria. Por ejemplo, “VACHz” significa que la pantalla primaria contiene la medición de voltaje de CA, y la pantalla secundaria contiene la medición de frecuencia. • VFD ~V y VFD Hz: Estas funciones utilizan filtros y algoritmos de rechazo de ruido para efectuar mediciones exactas de voltaje y frecuencia en la mayoría de motores de frecuencia variable. La medición de voltaje selecciona automáticamente la escala de 500 V. Use el botón RANGE para seleccionar otras escalas solamente cuando sea necesario. La sensibilidad para mediciones de frecuencia VFD depende de la escala de voltaje y de la frecuencia de entrada. Consulte “Frecuencia – Nivel de línea” en la sección “Exactitud” de este manual. • SELECT (Seleccionar): Oprímalo momentáneamente para alternar entre las funciones, modos de medición o modos de pantalla. El último ajuste utilizado se convierte en el valor por defecto cuando se vuelva a seleccionar dicha función. Para cambiar el valor por defecto, seleccione un nuevo ajuste. El ajuste será almacenado en una memoria estable. • RANGE (Escala): Oprímalo una vez para ingresar al modo de selección manual de escala. El icono desaparecerá de la pantalla. Oprímalo repetidamente para pasar de una escala a otra. Manténgalo oprimido para volver al modo de selección automática de escala. Aviso: Cuando se estén utilizando los modos CREST, REC, HOLD, o ∆, si se oprime el botón RANGE el medidor saldrá del modo en que se encuentre. • ∆: Le muestra la diferencia entre dos mediciones. Mientras efectúa una medición, oprima ∆ para poner la pantalla en ceros. Enseguida aparecerá el icono ∆ en la pantalla. Efectúe la segunda medición. El valor que aparezca en la pantalla equivaldrá a la diferencia entre ambas mediciones. Oprímalo nuevamente para salir de este modo. Esta característica se aplica solamente a la pantalla principal. • HOLD : Oprímalo momentáneamente para retener en pantalla el valor que aparece en ese momento. Oprímalo nuevamente para salir de este modo. Esta función no afecta al gráfico de barras. • CREST : Oprima momentáneamente este botón para activar el modo de grabación de cresta. En este modo, el valor de entrada se mide cada 1 milisegundos. y “MAX” aparecerán en la pantalla. En la pantalla LCD aparecerá el valor de cresta máximo. El medidor emitirá un tono siempre que se actualice el valor máximo o mínimo. Oprímalo repetidamente para seleccionar la pantalla deseada: máximo o mínimo valor de cresta. Mantenga oprimido el botón para salir de este modo. La función de apagado automático se desactiva al utilizar esta función. Aviso: Cuando se esté utilizando la función CREST, si se oprime el botón RANGE el medidor saldrá del modo en que se encuentre. • REC : Oprima momentáneamente este botón para activar el modo de grabación MAX/MIN/AVG. En este modo, el valor de entrada se mide cada 50 milisegundos. Enseguida aparecerán “MAX/MIN” y “AVG” en la pantalla. En la pantalla LCD aparecerá el valor del dato actual. El medidor emitirá un tono siempre que se actualice el valor máximo o mínimo. Oprímalo repetidamente para seleccionar la pantalla deseada: máximo, mínimo, promedio o dato real. Mantenga oprimido el botón para salir de este modo. 33 Cómo utilizar las distintas funciones (continuación) La función de apagado automático se desactiva al utilizar esta función. Aviso: Cuando se esté utilizando la función REC, si se oprime el botón RANGE el medidor saldrá del modo en que se encuentre. • : Manténgalo oprimido hasta que se ilumine la luz de fondo. Oprímalo nuevamente sin soltar para apagarla. La luz de fondo se apagará automáticamente después de aproximadamente 30 segundos a fin de preservar la vida útil de la pila. • dBm-Ω: La impedancia de referencia aparece durante un segundo después de seleccionar la función dBm. Oprima momentáneamente dBm-Ω para cambiar la impedancia de referencia. Consulte en la sección “Especificaciones” los valores disponibles. Aviso: Ésta es una medición de voltaje de CA calculada según la fórmula dBm = 20 x log (voltaje medido / voltaje de referencia El voltaje de referencia es aquel que causa que 1 mW de potencia se disipe en la impedancia de referencia seleccionada. • T1-T2: Oprima momentáneamente este botón para seleccionar la pantalla de temperatura deseada: T1, T2, T1T2 o T1-T2T2. • 500000: Oprima sin soltar el conmutador para alternar entre el modo rápido de 50.000 puntos y el modo de alta resolución de 500.000 puntos para mediciones de frecuencia y voltaje de CC. • Apagado automático inteligente (APO): A fin de prolongar la vida útil de la pila, el medidor se apaga por sí solo después de 17 minutos de inactividad. La inactividad ocurre cuando no se oprimen los botones o no se gira el interruptor de selección. El medidor no realizará la función de apagado automático inteligente (APO) cuando hayan lecturas importantes de más de 10% de la escala o lecturas para resistencia y continuidad que no sean indicativas de sobrecarga. Para restaurar la energía, oprima SELECT, RANGE, ∆, o HOLD o bien, gire el interruptor de selección hacia OFF y vuelva a encender la unidad. Para desactivar esta función, oprima SELECT (Seleccionar) al tiempo que enciende la unidad. • Cómo desactivar la función de tono audible: Mantenga oprimido el botón RANGE a la vez que enciende el medidor a fin de desactivar temporalmente la función de tono audible. Para activar el tono audible, gire el selector a la posición OFF y después vuelva a encenderlo. • Hz: Se puede medir la frecuencia en la mayoría de ajustes de voltaje y corriente del selector. Oprima SELECT hasta que aparezca “Hz” en la pantalla primaria o secundaria, según se desee. La sensibilidad de la función Frecuencia a nivel de línea varía con la escala de medición. Consulte la sección “Especificaciones”. Las mediciones con escala autoajustable usualmente establecen el mejor nivel de disparador. Si la lectura de frecuencia se vuelve inestable o queda en blanco, oprima el botón RANGE para seleccionar otro nivel de disparador. • %4-20 mA: Este valor calculado es una de tres opciones disponibles para la pantalla secundaria al medir miliamperios de CC. Esto es útil para aplicaciones de bucle de control de procesos industriales de 4-20 mA. Una lectura de 4 mA en la pantalla principal produce una lectura de 0% en la pantalla secundaria, 12 mA producen 50%, 20 mA producen 100%, etc. 34 DM-860A Medición de corriente alterna Las mediciones de corriente alterna generalmente se muestran como valores eficaces (RMS o root mean squared). El valor eficaz equivale al valor de una forma de onda de CC, la cual brinda la misma potencia que si reemplazara la forma de onda variable con el tiempo. Existen dos métodos de medición de corriente alterna: calibrados para responder al valor eficaz medio y a una lectura de valores eficaces reales. El método calibrado para responder al valor eficaz medio toma el valor medio de la señal de entrada luego de una rectificación total de onda, la multiplica por 1,11 y muestra el resultado. El resultado es exacto si la señal de entrada es una onda sinusoidal pura. El método de lectura de valores eficaces reales utiliza un circuito interno para leer el valor eficaz real. Este método es exacto, dentro de las limitaciones de factor de cresta especificadas, independientemente del tipo de señal de entrada, ya sea una onda sinusoidal pura, rectangular, triangular, media onda o señal con armónicas. La capacidad para leer valores eficaces reales brinda una mayor versatilidad de medición. La unidad DM-860A de Greenlee es un medidor de valores eficaces (RMS) reales. La tabla de Formas de onda y Factores de cresta muestra algunas de las señales de CA y sus valores eficaces reales más comunes. Formas de onda y Factores de cresta Forma de onda Valor eficaz 100 100 100 100 Valor medio 90 100 87 64 Factor de cresta* (x) 1,414 1 1,73 2 * El factor de cresta es el cociente de un valor máximo en relación con el valor eficaz; está representado por la letra griega x. Valor eficaz real CA + CC El valor eficaz real CA + CC calcula los componentes de CA y CC expresados al efectuar mediciones y responde acertadamente al valor eficaz efectivo total independientemente de la forma de onda. Formas de onda distorsionadas con la presencia de componentes de CC y armónicas podrían ocasionar: • el sobrecalentamiento de transformadores, generadores y motores • el disparo prematuro de interruptores automáticos de circuito • que fusibles se quemen • el sobrecalentamiento de neutrales debido a la presencia de armónicas triples en el neutral • la vibración de barras colectoras y paneles eléctricos 35 Ancho de banda de CA El ancho de banda de CA de un multímetro digital (DMM) es la gama de frecuencias sobre la cual se pueden efectuar mediciones de CA dentro de una precisión específica. Se trata de la respuesta de frecuencia de las funciones de CA—no de las funciones de medición de frecuencia. Un DMM no puede efectuar mediciones precisas de valores de CA con espectros de frecuencia que excedan el ancho de banda de CA. Por lo tanto, un ancho de banda de CA amplio desempeña un papel fundamental en multímetros digitales de alto rendimiento. Las formas de onda complejas, el ruido y las formas de onda distorsionadas contienen componentes de frecuencia mucho mayores que los fundamentales; por ejemplo, ruido de alta frecuencia en una línea de energía de 50/60 Hz. Operación Peligro de electrocución: El contacto con circuitos activados podría ocasionar graves lesiones o incluso la muerte. Modo de autodiagnóstico El mensaje “rE-O” puede aparecer cuando se enciende el medidor. Esto indica que el medidor está realizando un autodiagnóstico de rutina. No apague el medidor. Deje que termine el procedimiento de diagnóstico. Si aparece el mensaje “C_Er” en la pantalla al encender el medidor, algunas escalas pueden estar sustancialmente fuera de especificación. Para evitar mediciones erróneas, suspenda el uso del medidor y devuélvalo a Greenlee para su recalibración. Procedimiento de operación 1. Consulte la Tabla de ajustes. Coloque el interruptor de selección en el ajuste apropiado, oprima SELECT (cuando se le pida que lo haga), y conecte los cables de prueba al multímetro. 2. Consulte la sección “Mediciones más comunes” en relación con las instrucciones específicas para cada tipo de medición. 3. Pruebe la unidad en un circuito o componente que se sabe está funcionando perfectamente. • Si la unidad no funciona como debería en un circuito que se sabe está funcionando perfectamente, reemplace la pila y/o los fusibles. • Si la unidad aún sigue sin funcionar como debería, llame a Greenlee al 800-435-0786 para obtener asistencia técnica. 4. Anote la lectura del circuito o componente que se está verificando. 36 DM-860A Operación (continuación) Tabla de ajustes El medidor almacena la última función utilizada de cada una de las posiciones del interruptor de selección en su memoria no volátil. Si ésta no resulta ser la función correcta al girar el interruptor de selección, oprima SELECT hasta que aparezca el icono deseado. Las opciones de pantalla doble se muestran junto con los iconos. En la tabla, “~VHz” indica que “~” y “V” aparecen en la pantalla principal, y “Hz” aparece en la pantalla secundaria. Esta combinación muestra la medición de voltaje de CA en la pantalla primaria y la frecuencia en la pantalla secundaria. Para medir esta función … Coloque el interruptor de selección en este símbolo … Motor de velocidad variable—Voltaje y frecuencia Voltaje—CA RMS real (1000 V máx.) *Voltaje—CC (1000 V máx.) Voltaje—CA + CC RMS real (1000 V máx.) Voltaje—CC (500 mV máx.) Voltaje—CA + CC RMS real (500 mV máx.) Voltaje—CA RMS real (500 V máx.) % Ciclo de trabajo ΩV COM VHz o Hz~V ΩV COM ΩV COM ΩV COM ΩV COM mV~mV ΩV COM mVHz o Hz~mV ΩV COM V~V V~V mV~mV mV o Hz D% dBm dBm (0 dB = 1 mW en (función 1000 V impedancia de referencia) máx; función 500 mV máx.) Conecte Conecte el cable el cable de prueba de prueba rojo a … negro a … VHz o Hz~V Vo Colocar en voltaje Frecuencia—Nivel de línea o corriente según de voltaje o de corriente esta tabla. **Frecuencia—Nivel lógico Oprima SELECT hasta que estos iconos aparezcan en la pantalla … Cualquier opción de pantalla que incluya Hz ­— — Hz ΩV COM D% ΩV COM Impedancia de referencia y dBm durante 1 s, después dBmHz (oprima dBm-Ω para cambiar la impedancia de referencia) ΩV COM * Para mediciones exactas, oprima 500000 a fin de alternar entre 50.000 puntos y 500.000 puntos. Se aplica solamente a voltajes de CC. ** El nivel de frecuencia lógico tiene una sensibilidad fija La Tabla continúa en la siguiente página. y se aplica a señales digitales. Consulte “Exactitud”. 37 Operación (continuación) Tabla de ajustes (continuación) Para medir esta función … Coloque el interruptor de selección en este símbolo … Temperatura doble T1T2 Oprima SELECT hasta que estos iconos aparezcan en la pantalla … °C o °F (oprima RANGE para las opciones de pantalla T1, T2, T1T2 o T1-T2T2) Conecte Conecte el cable el cable de prueba de prueba rojo a … negro a … Ver las Notas 1 y 2 — †Capacitancia F ΩV COM Diodo V y diod ΩV COM Ω ΩV COM ΩV COM ΩV COM Resistencia Ω Continuidad yΩ Conductancia nS Corriente—CA, CC, o CA + CC RMS real (10 A máx.) A A, A~A, A~A, o AHz A COM Corriente—CA, CC, o CA + CC RMS real (600 mA máx.) mA mA%4-20mA, mA~mA, mA~mA, o mAHz mA µA COM Corriente—CA, CC, o CA + CC RMS real (6000 µA máx.) µA µA~µA, µA~µA, o µAHz mA µA COM Corriente de bucle de control de proceso industrial % 4 a 20 mA mA mA%4-20mA mA µA COM nS µA, † Descargue el capacitor antes de efectuar una medición. Consulte “Mediciones más comunes” respecto a los capacitores polarizados. Nota 1: T1+ se conecta a ΩV , y T1– se conecta a COM. Nota 2: T2+ se conecta a mA µA, y T2– se conecta a A. 38 DM-860A Mediciones más comunes Medición de voltaje Medición de corriente 39 Mediciones más comunes Medición de resistencia Verificación de continuidad Medición de capacitancia Verificación de diodo Polarización inversa Polarización directa Aviso: Para condensadores polarizados, conecte la sonda roja al terminal positivo y la sonda negra al terminal negativo del condensador. 40 DM-860A Mediciones más comunes Temperatura 41 Cómo utilizar el software opcional La unidad DM-860A es compatible con Greenlee DMSC-9U, un cable y software de interfaz ópticamente aislada de ordenador. Permite grabar mediciones en un ordenador personal utilizando el sistema operativo Microsoft® Windows®. Cómo instalar el software 1. Introduzca el CD en la unidad CDROM del ordenador. 2. El programa de instalación se iniciará automáticamente. Si no ocurre así, haga doble clic en el icono de CD en “Mi PC”. 3. Aparecerá el menú del programa de instalación. Haga clic en “Software Installation” (Instalación del software). 4. Escriba el número de catálogo de su medidor (por ejemplo, “DM-860A”) en el cuadro de diálogo. 5. Complete los cuadros de diálogo restantes según las preferencias del usuario. Cómo conectar el cable de interfaz USB óptico 1. Alinee la ranura en el conector con la ranura en el medidor. 2. Gire el conector en el sentido de las manillas del reloj hasta que caiga en su posición. 3. Conecte el cable a un puerto USB de la PC.. Ranura en la parte posterior del medidor 42 DM-860A Exactitud Consulte la sección “Especificaciones” en relación con las condiciones de operación y el coeficiente de temperatura. La exactitud se especifica de la siguiente manera: ± (un porcentaje de la lectura + una cantidad fija) a 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% a 75% de humedad relativa. Las especificaciones se refieren al modo de 50.000 puntos. Lecturas de valores RMS (eficaces) reales: Las precisiones de voltaje y corriente se especifican a partir del 5% hasta el 100% de la escala a menos que se indique algo diferente. La frecuencia debe hallarse dentro del ancho de banda especificado para formas de onda no sinusoidales. Los factores de cresta son los siguientes: • Factor de cresta < 2,1:1 a plena escala • Factor de cresta < 4,2:1 a escala media Corriente de CA, CCCA, y CA + CCCA Exactitud en CC y 50 Hz a 60 Hz 500,00 µA ± (0,5% + 0,5 µA) 5000,0 µA ± (0,5% + 5,0 µA) 50,000 mA ± (0,5% + 0,05 mA) 500,00 mA ± (0,5% + 0,5 mA) 5,0000 A ± (0,5% + 0,005 A) 10,000 A* ± (0,5% + 0,05 A) Escala   * 10 A Exactitud a 40 Hz hasta 1 Hz ± (0,7% + 0,5 µA) ± (0,7% + 5,0 µA) ± (0,7% + 0,05 mA) ± (0,7% + 0,5 mA) ± (0,7% + 0,005 A) ± (0,7% + 0,05 A) Exactitud a 1 kHz hasta 20 kHz ± (2,0% + 0,5 µA) ± (2,0% + 5,0 µA) ± (2,0% + 0,05 mA) ± (2,0% + 0,5 mA) No especificada No especificada Exactitud a 20 kHz hasta 100 kHz ± (5,0% + 0,5 µA) ± (5,0% + 5,0 µA) ± (5,0% + 0,05 mA) ± (5,0% + 0,5 mA) No especificada No especificada continuos; 20 A máximo (Régimen de trabajo: 30 segundos encendido, 5 minutos apagado). Escala 500,00 µA 5000,0 µA 50,000 mA 500,00 mA 5,0000 A 10,000 A Voltajes de carga (todas las escalas de frecuencia) 0,15 mV/µA 3,3 mV/mA 45 mV/A Corriente continua (CC) Escala 500,00 µA 5000,0 µA 50,000 mA 500,00 mA 5,0000 A 10,000 A*   * 10 A Exactitud ± (0,15% + 0,2 µA) ± (0,1% + 2,0 µA) ± (0,15% + 0,02 mA) ± (0,15% + 0,3 mA) ± (0,5% + 0,002 A) ± (0,5% + 0,02 A) Voltajes de carga 0,15 mV/µA 3,3 mV/mA 45 mV/A continuos; 20 A máximo (Régimen de trabajo: 30 segundos encendido, 5 minutos apagado). 43 Exactitud (continuación) Voltaje de CCCA y CA + CCCA Exactitud* a 20 Hz hasta 45 Hz 500,00 mV ± (1,5% + 0,4 mV) 5,0000 V ± (1,5% + 0,004 V) 50,000 V ± (1,5% + 0,04 V) 500,00 V No especificada 1000,0 V No especificada Escala Exactitud* de CC y 45 Hz hasta 1 kHz ± (0,5% + 0,4 mV) ± (0,5% + 0,008 V) ± (0,5% + 0,08 V) ± (0,5% + 0,8 V) ± (0,5% + 8 V) Exactitud* a 1 kHz hasta 20 kHz ± (1,0% + 0,4 mV) ± (1,2% + 0,004 V) ± (1,2% + 0,04 V) No especificada No especificada Exactitud* a 20 kHz hasta 40 kHz ± (3,5% + 0,4 mV)** ± (4,0% + 0,004 V)** ± (4,0% + 0,04 V)** No especificada No especificada   * Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 80 dígitos. 5% al 10% de la escala: Porcentaje de exactitud de lectura + 180 dígitos. Desde 10% al 15% de la escala: Porcentaje de exactitud de lectura + 100 dígitos. Lectura residual menor que 50 dígitos con los cables de prueba en cortocircuito. Aviso: “Dígitos” se refiere al dígito menos significativo (el número en la posición más a la derecha). ** Desde Voltaje de VFD CA Escala 5,0000 V 50,000 V 500,00 V 1000,0 V   * No Exactitud* a 5 Hz hasta 20 Hz ± (3% + 0,008 V) ± (3% + 0,08 V) ± (3% + 0,8 V) ± (3% + 8 V) Exactitud* a 20 Hz hasta 200 Hz ± (2% + 0,005 V) ± (2% + 0,05 V) ± (2% + 0,5 V) ± (2% + 5 V) Exactitud* a 200 Hz hasta 440 Hz ± (6% + 0,008 V)** ± (6% + 0,08 V)** ± (6% + 0,8 V)** ± (6% + 8 V)** está especificado para frecuencias fundamentales mayores que 440 Hz. **La exactitud decrece linealmente de ± (2,0% + 50 dígitos) a 200 Hz hasta ± (6% + 80 dígitos) a 440 Hz. 44 DM-860A Exactitud (continuación) Voltaje alterno (CA) Escala 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Escala 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Exactitud* a 20 Hz hasta 45 Hz ± (1,2% + 0,4 mV) ± (1,2% + 0,004 V) ± (1,2% + 0,04 V) No especificada No especificada Exactitud* a 45 Hz hasta 65 Hz ± (0,3% + 0,2 mV) ± (0,3% + 0,003 V) ± (0,3% + 0,03 V) ± (0,5% + 0,3 V) ± (0,5% + 3 V) Exactitud* a 10 kHz hasta 20 kHz ± (0,5% + 0,3 mV) ± (0,7% + 0,004 V) ± (0,7% + 0,04 V) ± (0,7% + 0,4 V) No especificada Exactitud* a 20 kHz hasta 100 kHz ± (2,5% + 0,4 mV)** ± (3,5% + 0,004 V)** ± (3,5% + 0,04 V)** No especificada No especificada Exactitud* a 65 Hz hasta 10 kHz ± (0,4% + 0,25 mV) ± (0,3% + 0,004 V) ± (0,3% + 0,04 V) ± (0,5% + 0,4 V) ± (0,8% + 4 V) (65 Hz hasta 1 kHz)   * Desde 5% al 10% de la escala: Porcentaje de exactitud de lectura + 80 dígitos. 5% al 10% de la escala: Porcentaje de exactitud de lectura + 180 dígitos. Lectura residual menor que 50 dígitos con los cables de prueba en cortocircuito. Aviso: “Dígitos” se refiere al dígito menos significativo (el número en la posición más a la derecha). ** Desde Voltaje continuo (CC) Escala 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Exactitud ± (0,02% + 0,02 mV) ± (0,02% + 0,0002 V) ± (0,03% + 0,002 V) ± (0,04% + 0,02 V) ± (0,15% + 0,2 V) Impedancia de entrada 10 MΩ, 80 pF nominales 10 MΩ, 60 pF nominales 45 Exactitud (continuación) Resistencia y conductancia Escala Exactitud 500,00 Ω 5,0000 kΩ 50,000 kΩ 500,00 kΩ 5,0000 MΩ 50,000 MΩ 99,99 nS ± (0,07% + 0,10 Ω) ± (0,07% + 0,0002 kΩ) ± (0,1% + 0,002 kΩ) ± (0,1% + 0,02 kΩ) ± (0,3% + 0,0006 MΩ) ± (2,0% + 0,006 MΩ) ± (0,8% + 0,10 nS)* Voltaje típico de circuito abierto 3,0 V CC 1,3 V CC *± (2,0% + 0,40 nS) por debajo de 9,99 nS. Capacitancia Escala 50,00 nF 500,0 nF 5,000 µF 50,00 µF 500,0 µF** 5,000 mF** 25,00 mF** Exactitud* ± (0,8% + 0,03 nF) ± (0,8% + 0,3 nF) ± (1,5% + 0,003 µF) ± (2,5% + 0,03 µF) ± (3,5% + 0,5 µF) ± (5,0% + 0,005 mF) ± (6,5% + 0,05 mF)   * Estas exactitudes son para los capacitores de película (capacitores con absorción dieléctrica insignificante). ** En modo manual de detección de escala, las escalas 500,0 µF, 5,000 mF, y 25,00 mF no están especificadas para valores menores de 45,0 µF, 0,450 mF, y 4,50 mF, respectivamente. Temperatura doble T1, T2, T1-T2 Escala –50 °C a 1000,0 °C –58 °F a 1832,0 °F   * No 46 Exactitud* ± (0,3% + 1,5 °C) ± (0,3% + 3,0 °F) se incluye la escala ni la exactitud del termopar. DM-860A Exactitud (continuación) Frecuencia—Nivel de línea Escala: 5,000 Hz a 200,00 kHz Exactitud: ± (0,02% + 4 dígitos) Escala de función CA 500 mV 5V 50 V 500 V 1000 V VFD 5 V VFD 50 V VFD 500 V Sensibilidad Escala (sinusoidal, valores RMS reales) 100 mV 0,5 V 5V 50 V 500 V 0,5 V a 2 V* 5 V a 20 V* 50 V a 200 V* 10 Hz a 200 kHz 10 Hz a 100 kHz 10 Hz a 10 kHz Escala de Sensibilidad función (sinusoidal, valores CA RMS reales) 500 µA 50 µA 5000 µA 500 µA 50 mA 5 mA 500 mA 50 mA 5A 1A 10 A 10 A Escala 10 Hz a 10 kHz 10 Hz a 3 kHz 10 Hz a 440 Hz   *La sensibilidad VFD decrece linealmente de 10% de la escala a 200 Hz hasta 40% de la escala a 440 Hz. Frecuencia—Nivel lógico Escala: 5,000 Hz a 2,0000 MHz Exactitud: ± (0,002% + 4 dígitos) Sensibilidad: Onda rectangular de 2,5 Vp % Ciclo de trabajo Escala: 0,1% a 99,99% Exactitud: ± (3 dígitos/kHz + 2 dígitos) Frecuencia de entrada: 5 Hz a 500 kHz, familia lógica de 5 V Verificación de diodos Escala de medición: 2,0000 V Corriente de prueba (típica): 0,4 mA Voltaje de circuito abierto: < 3,0 V CC Exactitud: ± (1% + 0,0001 V) Continuidad Umbral de tono: Entre 20 Ω y 200 Ω Tiempo de respuesta: < 100 µs dBm La escala y la exactitud dependen de la función de CA utilizada y la impedancia de referencia seleccionada. Impedancia de referencia seleccionable: 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200 Ω Captura de cresta (voltaje y corriente) para valores de cresta > 0,8 ms de duración Exactitud: Exactitud especificada ± 100 dígitos Resolución: 5000 dígitos 47 Especificaciones Pantalla: LCD Modo normal: 50.000 puntos Modo de alta resolución: 500.000 puntos Frecuencia: 99.999 puntos Gráfico de barras de 41 segmentos Polaridad: Automática Impedancia de entrada: 10 MΩ, 60 pF nominales (80 pF para escalas de 500 mV). Frecuencia de muestreo: Modo de 50.000 puntos: 5 por segundo, nominal Modo de 500.000 puntos: 1,25 por segundo, nominal Pantalla de gráfico de barras: 60 por segundo Coeficiente de temperatura: Nominal 0,15 x (Exactitud) por °C debajo de 18 °C desde 0 °C hasta 18 °C (32 °F hasta 64 °F) o por encima de 28 °C desde 28 °C hasta 40 °C (82 °F hasta 104 °F) a menos que se especifique de manera diferente Apagado automático inteligente: Después de 17 minutos de inactividad Indicación de pila sin carga: Por debajo de aproximadamente 7 V Supresión de ruido*: Factor de supresión en modo normal > 60 dB a 50 Hz y 60 Hz al efectuar mediciones de V CC Factor de supresión en modo común > 90 dB de 0 Hz a 60 Hz al efectuar mediciones de V CA Factor de supresión en modo común > 120 dB a 50 Hz y 60 Hz al efectuar mediciones de V CC Condiciones de operación: 0 °C a 31 °C (32 °F a 88 °F), 0% a 80% de humedad relativa 31 °C a 45 °C (88 °F a 113 °F), humedad relativa disminuyendo linealmente de 80% a 50% (sin condensación) Altitud: 2000 m (6500 pies) máxima Uso en interiores únicamente Grado de contaminación: 2 Condiciones de almacenamiento: –20 °C a 60 °C (–4 °F a 140 °F), 0% a 80% de humedad relativa (sin condensación) Retire la pila Pila: Pila de 9 voltios (NEDA 1604, JIS 006P o IEC 6F) E.M.C.: Cumple EN61326-1:2006 En un campo de RF de 3 V/m: No se especifica la función de capacitancia Escalas para otras funciones: Exactitud total = Exactitud especificada + 1000 dígitos No se especifica el desempeño por encima de 3 V/m * Supresión del ruido es la capacidad de suprimir señales o ruido indeseados. • Voltajes de modo normal son señales de CA que pueden ocasionar mediciones inexactas de CC. NMRR (Normal Mode Rejection Ratio o Factor de supresión en modo normal) es una medición de la capacidad para filtrar estas señales. • Voltajes de modo común son señales presentes en las terminales de entrada + y COM, con respecto a la conexión a tierra, que pueden causar alteraciones de dígitos o compensaciones en las mediciones de voltaje. CMRR (Common Mode Rejection Ratio o Factor de supresión en modo común) es una medición de la capacidad para filtrar estas señales. 48 DM-860A Especificaciones (continuación) Seguridad: Doble aislamiento por IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 y CAN/CSA-C22.2 Nº 61010-1-12 Ed. 3.0 a Categoría IV 1000 V CA/CC. Protecciones de sobrecarga: V: 1100 V CC/CA rms A: fusible 11 A/1000 V, capacidad de interrupción 20 kA, fusible F, 13/32" x 1-1/2" µA y mA: fusible 0,44 A/1000 V, capacidad de interrupción 10 kA, fusible F, 13/32" x 1-3/8" mV, Ω, y otras funciones: 1000 V CC/CA rms DIRECTIVAS CENELEC: Los instrumentos se ajustan a la directiva CENELEC de bajo voltaje 2006/95/CE y a la directiva de compatibilidad electromagnética 2004/108/CE Categorías de medición Las siguientes definiciones proceden de la norma de seguridad internacional sobre la coordinación de­ aislamientos tal y como se aplica a equipos de medición, control y laboratorio. En las publicaciones IEC 61010-1 y IEC 60664 de la International Electrotechnical Commission (Comisión Electrotécnica Internacional) se detallan más a fondo estas categorías de medición. Categoría de medición I Nivel de señal. Equipo electrónico y de telecomunicaciones, o partes del mismo. Como ejemplo pueden citarse los circuitos electrónicos protegidos contra tensiones momentáneas dentro de fotocopiadores y modems. Categoría de medición II Nivel local. Aparatos eléctricos, equipo portátil, y los circuitos a los que están conectados. Como ejemplo pueden citarse dispositivos de iluminación, televisores y circuitos de rama larga. Categoría de medición III Nivel de distribución. Máquinas instaladas permanentemente y los circuitos a los que están cableados. Como ejemplo pueden citarse sistemas conductores y los paneles del interruptor automático principal del sistema eléctrico de un edificio. Categoría de medición IV Nivel de abastecimiento primario. Líneas aéreas y otros sistemas de cable. Como ejemplo pueden citarse cables, medidores, transformadores y cualquier otro equipo exterior perteneciente a la empresa de servicio eléctrico. Certificado de Conformidad Greenlee Tools, Inc. cuenta con certificación conforme a ISO 9001:2008 para nuestros Sistemas de Gerencia de Calidad. El instrumento provisto ha sido inspeccionado y/o calibrado mediante el uso de equipo reconocido por el Instituto Nacional de Normas y Tecnologías (National Institute for Standards and Technology [NIST]). 49 Mantenimiento Peligro de electrocución: Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad. De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: Los fusibles son una parte integral para la protección contra sobretensión. Cuando sea necesario reemplazarlos, consulte la sección “Especificaciones” para saber qué tipo, tamaño y capacidad deben tener. Utilizar cualquier otro tipo de fusible anulará la clasificación de protección de sobretensión de la unidad. De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte. Cómo reemplazar la batería 1. Desconecte la unidad del circuito. Apague (OFF) la unidad. 2. Extraiga los dos tornillos de la puerta de acceso a la batería y retírela. 3. Cambie la batería y verifique la polaridad. Cómo cambiar los fusibles 1. Desconecte la unidad del circuito. Apague (OFF) la unidad. 2. Extraiga los dos tornillos de la puerta de acceso a la batería y retírela. 3. Desenrosque los dos tornillos dentro del compartimiento de la batería y los dos tornillos en la parte posterior del estuche. 4. Quite la cubierta posterior y cambie los fusibles. 5. Alinee las dos secciones de la unidad y las juntas de goma. 6. Asegúrese que el interruptor de selección esté en la posición original de modo que esté bien alineado con el interruptor interno. 7. Vuelva a colocar la cubierta y los tornillos. Limpieza y almacenamiento Limpie periódicamente la caja utilizando un paño húmedo y detergente suave; no utilice abrasivos ni solventes. Si el medidor no se usará durante períodos de más de 60 días, extraiga la batería y guárdela separadamente. 50 DM-860A Description Le multimètre numérique DM-860A de Greenlee est un appareil de contrôle portable offrant les capacités de mesure suivantes : tension alternative ou continue, intensité alternative ou continue, pourcentage de courant de boucle, deux canaux de température (thermocouples de type K), fréquence, coefficient d'utilisation, résistance, conductance et capacité. Il permet également la vérification de diodes et les contrôles de continuité. Le DM-860A comporte un affichage à barres graphiques, qui répond plus rapidement que l’affichage numérique — utile pour détecter les contacts défectueux, les déclics de potentiomètre et les pointes de signal. Une interface informatique à isolation optique avec logiciel, proposée en option, permet l'enregistrement des mesures de l'appareil sur un ordinateur. Les autres fonctions et capacités spéciales sont notamment : • Double afficheur présentant deux mesures, tension alternative et fréquence par exemple, simultanément. • Avertisseur Beep-Jack™ produisant un bip sonore et un message d'erreur à l'écran si le fil de mesure est branché dans la borne d'entrée mA µA ou A alors que le sélecteur n'est pas en position mA µA ou A. • Bande passante en courant alternatif de 100 kHz pour la tension et de 20 kHz pour l'intensité. • Fonction MAX/MIN, qui met en mémoire le maximum, le minimum et la moyenne. • Mode de saisie de crête, pour saisir les maxima des signaux de tension ou d'intensité. • Résolution sélectionnable entre 50 000 ou 500 000 points pour les mesures de tension continue. • Mode de zéro relatif. • Calibre automatique ou manuel. • Mise hors tension automatique intelligente. • Affichage à cristaux liquides rétroéclairé pour les mesures dans la pénombre. Sécurité Lors de l’utilisation et de l’entretien des outils et des équipements de Greenlee, votre sécurité est une priorité. Ce manuel d’instructions et toute étiquette sur l’outil fournit des informations permettant d’éviter des dangers ou des manipulations dangereuses liées à l’utilisation de cet outil. Suivre toutes les consignes de sécurité indiquées. Dessein de ce manuel Ce manuel d’instructions a pour objet de familiariser tout le personnel avec les procédures préconisées pour une utilisation et un entretien sans danger du multimètre numérique DM-860A de Greenlee. Mettre ce manuel à la disposition de tous les employés. On peut obtenir des exemplaires gratuits sur simple demande sur le site Web www.greenlee.com. Ne pas se débarrasser de ce produit ou le jeter ! Pour des informations sur le recyclage, visiter www.greenlee.com. 51 Consignes de sécurité importantes SYMBOLE D’AVERTISSEMENT Ce symbole met en garde contre les risques et les manipulations dangereuses pouvant entraîner des blessures ou l’endommagement du matériel. Le mot indicateur, défini ci-dessous, indique la gravité du danger. Le message qui suit le mot indicateur indique comment e­ mpêcher le danger. Danger immédiat qui, s’il n’est pas pris en considération ENTRAINERA des blessures graves, voire mortelles. Danger qui, s’il n’est pas pris en considération, POURRAIT entraîner des blessures graves, voire mortelles. Dangers ou manipulations dangereuses qui, s’ils ne sont pas pris en considération, POURRAIENT EVENTUELLEMENT entraîner des dommages à la propriété ou causer des blessures. Lire attentivement et bien comprendre cette documentation avant d’utiliser ou de procéder à l’entretien de cet équipement. Négliger de comprendre comment utiliser cet outil en toute sécurité pourrait provoquer un accident et entraîner des blessures graves, voire mortelles. Risque de décharge électrique : Un contact avec des circuits sous tension pourrait entraîner des blessures graves, voire mortelles. Toutes les spécifications sont nominales et peuvent changer avec l’amélioration de la conception. Greenlee Tools, Inc. ne peut être tenue responsable des dommages résultant d’une application inappropriée ou d’un mauvais usage de ses produits. ® Déposé : La couleur verte des instruments de vérification électrique est une marque déposée de Greenlee Tools, Inc. Beep-Jack est une marque de commerce de BTC. Microsoft et Windows sont des marques déposées de Microsoft Corporation. 52 CONSERVER CE MANUEL DM-860A Consignes de sécurité importantes Risques de décharge électrique et d’incendie : • Ne pas exposer cet appareil à la pluie ou à l’humidité. • Ne pas utiliser cet appareil s’il est mouillé ou endommagé. • Utilisez exclusivement les fils de test fournis avec l’équipement ou des sondes homologuées UL ayant une qualification identique ou supérieure. • Vérifier les fils d’essai ou l’accessoire avant de les utiliser. La pièce (ou les pièces) doi(ven)t être propre(s) et sèche(s) et l’isolation en bon état. Si la couche isolante interne, de couleur contrastée, est visible, n’utilisez pas le fil. • Utiliser cet appareil uniquement dans le but pour lequel il a été conçu, tel que décrit dans ce manuel. Toute autre utilisation peut altérer le système de protection de cet appareil. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : • Ne pas appliquer plus que la tension nominale entre deux bornes d’entrée, ou entre une borne d’entrée et une prise de terre. • Ne pas entrer en contact avec les extrémités des fils d’essai ou avec toute autre partie non isolée de l’accessoire. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : • Ne pas utiliser lorsq ue le boîtier est ouvert. • Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : Les fusibles forment une partie intégrante du système de protection de surtension. Lorsqu’un fusible doit être remplacé, consulter les caractéristiques techniques pour connaître le type, la taille et la capacité requis. L’utilisation de tout autre type de fusible annule l’étalonnage de protection contre la surtension de l’appareil. L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles. 53 Consignes de sécurité importantes Risques de décharge électrique : • Sauf si l’on mesure la tension, le courant ou la fréquence, mettre hors tension et couper la source d’alimentation. S’assurer que tous les condensateurs sont déchargés. Aucune tension ne doit être présente. • Régler le sélecteur et connecter les fils d’essai pour qu’ils correspondent à la mesure voulue. Des réglages ou des connexions incorrects peuvent faire sauter les fusibles. • L’utilisation de cet appareil à proximité d’équipements qui génèrent des interférences électromagnétiques peut produire des lectures instables ou erronées. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : Ne pas modifier la fonction de mesure pendant que les fils d’essai sont connectés à un composant ou à un circuit. L’inobservation de cette consigne pourrait endommager l’appareil et pourrait entraîner des blessures. Risques de décharge électrique : • Ne pas tenter de réparer cet appareil. Il ne comporte aucune pièce pouvant être réparée. • Ne pas exposer l’appareil à des températures ou à une humidité extrêmes. Voir les caractéristiques techniques. L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner des blessures. 54 DM-860A Identification 1. Affichage 2. Boutons de fonctions 3. Sélecteur 4. A 5. mA µA 6. COM 7. ΩV Cristaux liquides (LCD) et graphique à barres Voir les explications sous « Utilisation des fonctions » Sélectionne une fonction ou met hors tension (OFF). Borne d’entrée positive pour les mesures d'intensités élevées ; borne d'entrée négative pour T2 Borne d’entrée positive pour les mesures de faibles intensités ; borne d'entrée positive pour T2 Borne d’entrée négative, commune ou de terre pour toutes les mesures Borne d’entrée positive pour toutes les mesures sauf l'intensité 1 2 3 4 7 5 6 Symboles apparaissant sur l’appareil Avertissement — Lire le manuel d’instructions Isolation double 55 Icônes de l’afficheur Affichage principal 33. Hz 8. 9. – Segment de graphique à barres Indicateur de polarité pour le graphique à barres 10. Échelle du graphique à barres 11. ∆ Fonction de zéro relatif activée 12. VFD Fonction VFD activée 13. – Indicateur de polarité 14. 8.8.8.8.88 Affichage numérique 15. T1-T2 Fonction T1, T2, ou T1-T2 activée 16. Mesure de courant alternatif sélectionnée 17. Mesure de courant continu sélectionnée 18. MAX Valeur maximale enregistrée ou affichée 19. MIN Valeur minimale enregistrée ou affichée 20. AVG Valeur moyenne enregistrée ou affichée 21. Fonction d’enregistrement activée 22. Fonction de saisie de crête activée 23. Fonction de rétention activée 24. Sélection de calibre automatique activée 25. Continuité 26. Pile déchargée 27. } Symbole de surcharge (graphique à barres) 28. 5 Indicateur de plage maximale du graphique à barres 29. D% Fonction de coefficient d'utilisation 24 activée 21-23 30. k Kilo (103) 18-20 31. M Méga (106) 32. Ω Ohm 16-17 15 13-14 12 11 10 56 8-9 34. dBm 35. m 36. µ 37. V 38. A 39. n 40. F 41. S Hertz (fréquence en cycles par seconde) Décibel Milli (10-3) Micro (10-6) Volt Ampère Nano (10-9) Farad Siemens Affichage secondaire 42. %4-20mA Fonction de courant de boucle de régulation de procédé activée 43. µ Micro (10-6) 44. m Milli (10-3) 45. A Ampère 46. V Volt 47. M Méga (106) 48. k Kilo (103) 49. Hz Hertz (fréquence en cycles par seconde) 50. 8.8.8.8 Affichage numérique 51. T2 Fonction T2 activée 52. Mesure de courant alternatif sélectionnée 53. – Indicateur de polarité 51-53 25 26 50 47-49 43-46 42 29-41 28 27 DM-860A Utilisation des fonctions • Double affichage numérique : Cet appareil peut afficher simultanément deux mesures, la tension alternative et la fréquence par exemple. Les combinaisons d'affichage sont indiquées au moyen de symboles de grande taille pour l'affichage principal et de symboles plus petits en hauteur pour les mesures sur l'affichage secondaire. Par exemple, « VACHz » signifie que l'affichage principal présente une mesure de tension alternative et l'affichage secondaire la mesure de fréquence correspondante. • VFD ~V et VFD Hz : Ces fonctions font appel à des algorithmes de filtrage et d'élimination du bruit pour effectuer des mesures de tension et de fréquence précises sur la majorité des commandes à fréquence variable (VFD). La mesure de tension sélectionne automatiquement le calibre 500 V. Utiliser le bouton RANGE pour sélectionner d'autres calibres uniquement si cela est nécessaire. La sensibilité des mesures de fréquence de VFD dépend du calibre de tension et de la fréquence d'entrée. Voir « Fréquence – Niveau de ligne » dans la section « Précision » de ce manuel. • SELECT : Appuyer brièvement pour passer d'une fonction, d'un mode de mesure ou d'un mode d'affichage à l'autre. Le dernier réglage utilisé devient le réglage par défaut lorsque la fonction considérée est sélectionnée une nouvelle fois. Pour changer de réglage par défaut, en sélectionner un nouveau. Le réglage est conservé dans une mémoire non volatile. • RANGE : Appuyer une fois pour passer en mode de sélection manuelle du calibre. L'icône disparaît de l'afficheur. Appuyer de façon répétée pour faire défiler les calibres. Tenir enfoncé pour revenir au mode de sélection automatique du calibre. Remarque : Lors de l’utilisation du mode CREST, REC, HOLD ou ∆, appuyer sur RANGE pour quitter ce mode. • ∆ : Calcule la différence entre deux mesures. Pendant la mesure, appuyer sur ∆ pour ramener l'affichage à zéro. L’icône ∆ apparaît sur l’afficheur. Effectuer la deuxième mesure. La valeur affichée représente la différence entre les deux mesures. Appuyer une nouvelle fois pour quitter ce mode. Cette fonction s'applique à l'affichage principal seulement. • HOLD : Appuyer brièvement pour figer l'affichage de la valeur courante. Appuyer une nouvelle fois pour quitter ce mode. Cette fonction n'a aucun effet sur le graphique à barres. • CREST : Appuyer brièvement pour activer le mode d'enregistrement de crête. Dans ce mode, la valeur d'entrée est mesurée toutes les 1 ms. et « MAX » s'affichent à l'écran. La valeur de crête maximale est affichée. L'appareil émet un bip à chaque mise à jour du maximum ou du minimum. Appuyer de façon répétée pour sélectionner l'affichage souhaité : valeur de crête maximale ou minimale. Tenir enfoncé pour quitter ce mode. La fonction de mise hors tension automatique est désactivée lorsque cette fonction est utilisée. Remarque : Lors de l'utilisation de la fonction CREST, appuyer sur RANGE pour quitter ce mode. • REC : Appuyer brièvement pour activer le mode d'enregistrement MAX/MIN/AVG. La valeur d'entrée est mesurée toutes les 50 ms dans ce mode. « MAX MIN » et « AVG »* s'affichent à l'écran. La valeur d'entrée instantanée est affichée. L'appareil émet un bip à chaque mise à jour du maximum ou du minimum. Appuyer de façon répétée pour sélectionner l'affichage souhaité : maximum, minimum, moyenne ou entrée instantanée. Tenir enfoncé pour quitter ce mode. La fonction de mise hors tension automatique est désactivée lorsque cette fonction est utilisée. Remarque : Lors de l'utilisation de la fonction REC, appuyer sur RANGE pour quitter ce mode. 57 Utilisation des fonctions (suite) • : Maintenir enfoncé jusqu'à ce que le rétroéclairage s'allume. Maintenir enfoncé une nouvelle fois pour l'éteindre. Le rétroéclairage s’éteint au bout de 30 secondes pour économiser la pile. • dBm-Ω : L'impédance de référence s'affiche pendant 1 seconde une fois que la fonction dBm est sélectionnée. Appuyer brièvement sur dBm-Ω pour changer l'impédance de référence. Voir les valeurs disponibles dans la section « Caractéristiques techniques ». Remarque : Ceci est une mesure de tension alternative calculée suivant la formule dBm = 20 x log (tension mesurée / tension de référence) La tension de référence et la tension qui produit la dissipation de 1 mW de puissance dans l'impédance de référence sélectionnée. • T1-T2 : Appuyer brièvement pour sélectionner l'affichage de température souhaité : T1, T2, T1T2, ou T1-T2T2. • 500000 : Tenir enfoncé pour alterner entre le mode rapide à 50 000 points et le mode haute résolution à 500 000 points pour les mesures de tension continue. • Mise hors tension automatique intelligente (APO) : Pour prolonger l'autonomie de la pile, le multimètre s’éteint automatiquement au bout de 17 minutes d’inactivité environ. L'inactivité se produit lorsqu'aucun bouton n'est enfoncé et que le sélecteur n'est pas actionné. Le multimètre n'entre pas en mode APO s'il y a des mesures significatives de plus de 10 % du calibre ou des mesures de résistance et de continuité sans surcharge. Pour remettre sous tension, appuyer sur SELECT, RANGE, ∆ ou HOLD ou mettre le sélecteur sur OFF puis le remettre en position de marche. Pour désactiver cette fonction, appuyer sur SELECT alors que l'appareil est en marche. • Désactivation du bip sonore : Tenir le bouton RANGE enfoncé tout en mettant l'appareil sous tension pour désactiver provisoirement la fonction de bip sonore. Mettre le sélecteur sur OFF puis le remettre en position de marche pour rétablir le bip sonore. • Hz : La fréquence peut être mesurée pour la majorité des réglages de tension et d'intensité du sélecteur. Appuyer sur SELECT jusqu'à afficher « Hz », au choix, dans l'affichage primaire ou secondaire. La sensibilité de la fonction de fréquence de niveau de ligne varie en fonction du calibre de mesure. Voir « Caractéristiques techniques ». Les mesures par calibre automatique présentent habituellement le meilleur niveau de déclenchement. Si la mesure de fréquence devient instable ou disparaît, appuyer sur le bouton RANGE pour sélectionner un autre niveau de déclenchement. • %4-20mA : Cette valeur calculée est l'une des trois options disponibles pour l'affichage secondaire lors de la mesure d'intensités continues en milliampères. Elle est utile pour les mesures de boucles de régulation de procédé industriel de 4-20 mA. Une mesure de 4 mA sur l'affichage principal produit une mesure de 0 % sur l'affichage secondaire, 12 mA produit 50 %, 20 mA produit 100 %, etc. 58 DM-860A Mesure de courant alternatif En règle générale, les mesures de courant alternatif sont affichées en valeurs efficaces (RMS). La valeur efficace équivaut à la valeur d’une forme d’onde de courant continu, qui fournirait la même puissance si elle remplaçait la forme d’onde qui varie en fonction du temps. Les deux méthodes de mesure du courant alternatif sont la mesure de valeur efficace de réponse moyenne étalonnée et la mesure de valeur efficace vraie. La méthode par valeur efficace de réponse moyenne étalonnée consiste à mesurer la valeur moyenne du signal d’entrée après un redressement à double alternance, à la multiplier par 1,11 et à afficher le résultat. Cette méthode est précise si le signal d’entrée est une onde sinusoïdale pure. La méthode par mesure de la valeur efficace vraie fait appel à un circuit interne permettant de mesurer directement la valeur efficace. Cette méthode est précise dans les limites du facteur de crête spécifiées, que le signal soit une onde sinusoïdale pure, une onde carrée, une onde triangulaire, une demi-onde ou un signal comportant des harmoniques. Les appareils à mesure de valeur efficace vraie sont beaucoup plus polyvalents que les appareils conventionnels. Le DM-860A de Greenlee offre des mesures de valeur efficace vraie. Le tableau des formes d’onde et facteurs de crête fournit les valeurs efficaces des signaux alternatifs courants. Formes d’ondes et facteurs de crêtes Forme d’onde Valeur RMS 100 100 100 100 Valeur moyenne 90 100 87 64 Facteur de crête* (x) 1,414 1 1,73 2 * Le facteur de crête correspond au rapport de la valeur de crête sur la valeur efficace ; il est représenté par la lettre grecque x. Valeur efficace vraie AC + DC La valeur efficace vraie AC + DC distingue les composantes alternative et continue suivant l'expression données par l’expression lors de la prise des mesures et reproduit avec précision la valeur efficace vraie totale réelle indépendamment de la forme d’onde. Les formes d’ondes déformées par la présence de composantes continues et d’harmoniques peuvent entraîner : • une surchauffe des transformateurs, des groupes électrogènes et des moteurs • un déclenchement prématuré des disjoncteurs • une condition où les fusibles vont griller • une surchauffe des neutres à cause de la triple harmonique présente dans le neutre • une vibration des barres omnibus et des panneaux électriques 59 Bande passante en courant alternatif La bande passante en courant alternatif d’un multimètre numérique (DMM) est la gamme des fréquences qui permettent d’effectuer des mesures de courant alternatif avec la précision requise. Elle constitue la réponse de fréquence de ces fonctions et non leur mesure de fréquence. Un DMM ne peut mesurer avec précision la valeur alternative pour des spectres de fréquences hors de la bande passante en courant alternatif du DMM. En conséquence, une bande passante large est d'une grande importance pour les DMM à haute performance. Les formes d’ondes complexes et déformées, de même que le bruit, contiennent des composantes de fréquences bien supérieures à un bruit haute fréquence comme, par exemple, celui d’une ligne sous tension à 50/60 Hz. Utilisation Risque de décharge électrique : Un contact avec des circuits sous tension pourrait entraîner des blessures graves, voire mortelles. Mode d'autodiagnostic Le message « rE-O » peut s'afficher à la mise en marche du multimètre. Il indique que l'appareil est en train d'exécuter un autodiagnostic de routine. Ne pas le mettre à l'arrêt. Laisser la procédure de diagnostic se terminer. Si le message « C_Er » s'affiche à la mise en marche du multimètre, il est possible que certains calibres soient largement hors limites. Pour éviter les erreurs de mesure, cesser d'utiliser le multimètre et le renvoyer à Greenlee pour être réétalonné. Mode d'emploi 1. Se reporter au Tableau des réglages. Placer le sélecteur sur le réglage qui convient, appuyer sur SELECT (lorsque l'instruction en est donnée) et raccorder les fils d'essai au multimètre. 2. Voir les instructions de mesure particulières sous « Mesures types ». 3. Tester l’appareil sur un circuit ou un composant connu. • Si l’appareil ne fonctionne pas comme prévu sur un circuit opérationnel connu, changer la pile et/ ou les fusibles. • Si l’appareil ne fonctionne toujours pas comme prévu, appeler le service d'assistance technique de Greenlee au 800-435-0786. 4. Effectuer la mesure sur le circuit ou le composant à contrôler. 60 DM-860A Utilisation (suite) Tableau des réglages Le multimètre conserve la dernière fonction utilisée pour chaque position du sélecteur dans sa mémoire non volatile. Après avoir réglé le sélecteur, si cette fonction n'est pas celle souhaitée, appuyer sur SELECT jusqu'à ce que l'icône souhaitée s'affiche. Les options de double affichage sont indiquées en même temps que les icônes. Dans le tableau, « ~VHz » signifie que « ~ » et « V » apparaissent dans l'affichage principal et « Hz » dans l'affichage secondaire. Cette combinaison présente la mesure de tension alternative dans l'affichage principal et la fréquence correspondante dans l'affichage secondaire. Pour mesurer cette caractéristique … Régler le Appuyer sur SELECT Raccorder Raccorder sélecteur sur ce jusqu'à l'affichage de le fil rouge le fil noir symbole … ces icônes … à … à… Commande à vitesse variable— Tension et fréquence Tension—Valeur eff. vraie alt. (1 000 V max) *Tension—Continue (1 000 V max) Tension—Valeur eff. vraie alt. + cont. (1000 V max) Tension—Continue (500 mV max) Tension—Valeur eff. vraie alt. + cont. (500 mV max) Tension—Valeur eff. vraie alternative (500 V max) Fréquence—Tension ou intensité de niveau de ligne **Fréquence—Niveau logique VHz ou Hz~V ΩV COM VHz ou Hz~V ΩV COM ΩV COM ΩV COM ΩV COM mV~mV ΩV COM mVHz ou Hz~mV ΩV COM V~V V ou V~V mV ou mV~mV Régler sur tension Toute option d'affichage ou intensité qui inclut Hz suivant ce tableau. Hz Coefficient d'utilisation (%) D% dBm (0 dB = 1 mW dans l'impédance de référence) dBm (fonction 1000 V max ; fonction 500 mV max.) ­— — Hz ΩV COM D% ΩV COM Impédance de référence et dBm pendant 1 s, puis dBmHz (appuyer sur ΩV dBm-Ω pour changer d'impédance de référence) COM * Pour effectuer des mesures précises, appuyer sur 500000 pour alterner entre 50 000 points et 500 000 points de mesure. S'applique aux tensions continues seulement. ** La fréquence de niveau logique a une sensibilité fixe et s'utilise avec des signaux numériques. Voir « Précision ». Ce tableau continue à la page suivante. 61 Utilisation (suite) Tableau des réglages (suite) Pour mesurer cette caractéristique … Double température Régler le Appuyer sur SELECT Raccorder Raccorder sélecteur sur ce jusqu'à l'affichage de le fil rouge le fil noir symbole … ces icônes … à … à… °C ou °F (appuyer sur Voir les RANGE pour les options T1T2 Notes — T2 d'affichage T1, T2, T1 1 et 2 T2 ou T1-T2 ) †Capacité F ΩV COM Diode V et diod ΩV COM Ω ΩV COM ΩV COM ΩV COM Résistance Ω Continuité et Ω Conductance nS Intensité—Valeur eff. vraie alt., cont. ou alt. + cont (10 A max) A A, A~A, A~A, ou AHz A COM Intensité—Valeur eff. vraie alt., cont. ou alt. + cont. (600 mA max) mA mA%4-20mA, mA~mA, mA~mA, ou mAHz mA µA COM Intensité—Valeur eff. vraie alt., cont. ou alt. + cont. (6 000 µA max) µA µA~µA, µA~µA, ou µAHz mA µA COM Courant de boucle de régulation de procédé industriel % 4 à 20 mA mA mA%4-20mA mA µA COM nS µA, † Décharger les condensateurs avant la mesure. Voir « Mesures types » concernant les condensateurs polarisés Note 1: Raccorder T1+ à ΩV et T1– à COM. Note 2: Raccorder T2+ à mA µA and T2– à A. 62 DM-860A Mesures types Mesure de tension Mesure d’intensité 63 Mesures types Mesure de résistance Contrôle de continuité Mesure de capacité Mesure de diode Polarisation inverse Polarisation directe Remarque : Pour les condensateurs polarisés, raccorder le fil rouge à la borne positive et le fil noir à la borne négative du condensateur. 64 DM-860A Mesures types Température 65 Utilisation du logiciel en option Le DM-860A est compatible avec le DMSC-9U de Greenlee, un système de câble et logiciel d’interface informatique à isolation optique. Il permet de transférer les mesures vers un micro-ordinateur utilisant le système d’exploitation Microsoft® Windows®. Installation du logiciel 1. Introduire le CD dans le lecteur CDROM de l’ordinateur. 2. Le programme d’installation devrait démarrer automatiquement. S’il ne démarre pas, doublecliquer sur l’icône du CD dans « Poste de travail ». 3. Le menu du programme d’installation s’affiche. Cliquer sur « Software Installation ». 4. Entrer le numéro de référence du multimètre (par exemple, « DM-860A ») dans la boîte de dialogue. 5. Répondre aux boîtes de dialogue suivantes pour définir les préférences de l’utilisateur. Raccordement du câble d’interface USB optique 1. Aligner la clavette du connecteur avec la rainure sur le multimètre. 2. Tourner le connecteur dans le sens des aiguilles d’une montre pour l’enclencher. 3. Raccorder le câble à un port USB de l’ordinateur. Rainure de clavette au dos du multimètre 66 DM-860A Précision Voir les conditions d’utilisation et le coefficient de température dans la section « Caractéristiques techniques ». La précision est spécifiée comme suit : ± (un pourcentage de la mesure + une quantité fixe) à 23 °C ± 5 °C (73,4 °F ± 9 ºF), 0 % à 75 % d’humidité relative. Ces caractéristiques concernent le mode à 50 000 points. Mesures de valeur efficace vraie (True RMS) : Sauf indication contraire, les précisions de tension et d’intensité spécifiées s’appliquent de 5 % à 100 % du calibre. La fréquence doit être dans les limites de la largeur de bande spécifiée pour les ondes non sinusoïdales. Les facteurs de crête sont les suivants : • Facteur de crête < 2,1 : 1 à pleine échelle • Facteur de crête < 4,2 : 1 à mi-échelle Intensité AC, DCAC et AC + DCAC Calibre 500,00 µA 5000,0 µA 50,000 mA 500,00 mA 5,0000 A 10,000 A*   * 10 A Précision cour. cont. et de 50 Hz à 60 Hz ± (0,5% + 0,5 µA) ± (0,5% + 5,0 µA) ± (0,5% + 0,05 mA) ± (0,5% + 0,5 mA) ± (0,5% + 0,005 A) ± (0,5% + 0,05 A) Précision de 40 Hz à 1 kHz ± (0,7% + 0,5 µA) ± (0,7% + 5,0 µA) ± (0,7% + 0,05 mA) ± (0,7% + 0,5 mA) ± (0,7% + 0,005 A) ± (0,7% + 0,05 A) Précision de 1 kHz à 20 kHz ± (2,0% + 0,5 µA) ± (2,0% + 5,0 µA) ± (2,0% + 0,05 mA) ± (2,0% + 0,5 mA) Non spécifié Non spécifié Précision de 20 kHz à 100 kHz ± (5,0% + 0,5 µA) ± (5,0% + 5,0 µA) ± (5,0% + 0,05 mA) ± (5,0% + 0,5 mA) Non spécifié Non spécifié continus ; 20 A maximum (coeff. d'utilisation : 30 s activé, 5 min désactivé). Tensions absorbées (toutes plages de fréquence) Calibre 500,00 µA 5000,0 µA 50,000 mA 500,00 mA 5,0000 A 10,000 A 0,15 mV/µA 3,3 mV/mA 45 mV/A Intensité continue Calibre 500,00 µA 5000,0 µA 50,000 mA 500,00 mA 5,0000 A 10,000 A*   * 10 A Précision ± (0,15% + 0,2 µA) ± (0,1% + 2,0 µA) ± (0,15% + 0,02 mA) ± (0,15% + 0,3 mA) ± (0,5% + 0,002 A) ± (0,5% + 0,02 A) Tensions absorbées 0,15 mV/µA 3,3 mV/mA 45 mV/A continus ; 20 A maximum (coeff. d'utilisation : 30 s activé, 5 min désactivé). 67 Précision (suite) Tension DCAC et AC + DCAC Calibre Précision* de 20 Hz à 45 Hz 500,00 mV ± (1,5% + 0,4 mV) 5,0000 V ± (1,5% + 0,004 V) 50,000 V ± (1,5% + 0,04 V) 500,00 V Non spécifié 1000,0 V Non spécifié Précision* cour. cont. et de 45 Hz à 1 kHz ± (0,5% + 0,4 mV) ± (0,5% + 0,008 V) ± (0,5% + 0,08 V) ± (0,5% + 0,8 V) ± (0,5% + 8 V) Précision* de 1 kHz à 20 kHz Précision* de 20 kHz à 40 kHz ± (1,0% + 0,4 mV) ± (1,2% + 0,004 V) ± (1,2% + 0,04 V) Non spécifié Non spécifié ± (3,5% + 0,4 mV)** ± (4,0% + 0,004 V)** ± (4,0% + 0,04 V)** Non spécifié Non spécifié   * De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 80 chiffres. 5 % à 10 % du calibre : Pourcentage de précision de mesure + 180 chiffres. De 10 % à 15 % du calibre : Pourcentage de précision de mesure + 100 chiffres. Mesure résiduelle moins de 50 chiffres avec fils d'essai en court circuit Remarque : « Chiffres » fait référence au chiffre le moins significatif (le chiffre le plus à droite du nombre). ** De Tension VFD AC Calibre 5,0000 V 50,000 V 500,00 V 1000,0 V   * Non Précision* de 5 Hz à 20 Hz ± (3% + 0,008 V) ± (3% + 0,08 V) ± (3% + 0,8 V) ± (3% + 8 V) Précision* de 20 Hz à 200 Hz ± (2% + 0,005 V) ± (2% + 0,05 V) ± (2% + 0,5 V) ± (2% + 5 V) spécifiée pour une fréquence fondamentale supérieure à 440 Hz. **La précision diminue linéairement de ± (2,0 % + 50 chiffres) à 200 Hz à ± (6 % + 80 chiffres) à 440 Hz. 68 Précision* de 200 Hz à 440 Hz ± (6% + 0,008 V)** ± (6% + 0,08 V)** ± (6% + 0,8 V)** ± (6% + 8 V)** DM-860A Précision (suite) Tension AC Calibre 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Calibre 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Précision* de 20 Hz à 45 Hz ± (1,2% + 0,4 mV) ± (1,2% + 0,004 V) ± (1,2% + 0,04 V) Non spécifié Non spécifié Précision* de 45 Hz à 65 Hz ± (0,3% + 0,2 mV) ± (0,3% + 0,003 V) ± (0,3% + 0,03 V) ± (0,5% + 0,3 V) ± (0,5% + 3 V) Précision* de 10 kHz à 20 kHz ± (0,5% + 0,3 mV) ± (0,7% + 0,004 V) ± (0,7% + 0,04 V) ± (0,7% + 0,4 V) Non spécifié Précision* de 20 kHz à 100 kHz ± (2,5% + 0,4 mV)** ± (3,5% + 0,004 V)** ± (3,5% + 0,04 V)** Non spécifié Non spécifié Précision* de 65 Hz à 10 kHz ± (0,4% + 0,25 mV) ± (0,3% + 0,004 V) ± (0,3% + 0,04 V) ± (0,5% + 0,4 V) ± (0,8% + 4 V) (65 Hz à 1 kHz)   * De 5 % à 10 % du calibre : Pourcentage de précision de mesure + 80 chiffres. 5 % à 10 % du calibre : Pourcentage de précision de mesure + 180 chiffres. Mesure résiduelle moins de 50 chiffres avec fils d'essai en court circuit Remarque : « Chiffres » fait référence au chiffre le moins significatif (le chiffre le plus à droite du nombre). ** De Tension DC Calibre 500,00 mV 5,0000 V 50,000 V 500,00 V 1000,0 V Précision ± (0,02% + 0,02 mV) ± (0,02% + 0,0002 V) ± (0,03% + 0,002 V) ± (0,04% + 0,02 V) ± (0,15% + 0,2 V) Impédance d’entrée 10 MΩ, 80 pF nominal 10 MΩ, 60 pF nominal 69 Précision (suite) Résistance et conductance Calibre Précision 500,00 Ω 5,0000 kΩ 50,000 kΩ 500,00 kΩ 5,0000 MΩ 50,000 MΩ 99,99 nS ± (0,07% + 0,10 Ω) ± (0,07% + 0,0002 kΩ) ± (0,1% + 0,002 kΩ) ± (0,1% + 0,02 kΩ) ± (0,3% + 0,0006 MΩ) ± (2,0% + 0,006 MΩ) ± (0,8% + 0,10 nS)* *± Tension circuit ouvert type 3,0 VDC 1,3 VDC (2,0 % + 0,40 nS) en dessous de 9,99 nS. Capacité Calibre 50,00 nF 500,0 nF 5,000 µF 50,00 µF 500,0 µF** 5,000 mF** 25,00 mF** Précision* ± (0,8% + 0,03 nF) ± (0,8% + 0,3 nF) ± (1,5% + 0,003 µF) ± (2,5% + 0,03 µF) ± (3,5% + 0,5 µF) ± (5,0% + 0,005 mF) ± (6,5% + 0,05 mF)   * Précisions Double température T1, T2, T1-T2 Plage –50 °C à 1000,0 °C –58 °F à 1832,0 °F   * Précision Précision* ± (0,3% + 1,5 °C) ± (0,3% + 3,0 °F) et plage du thermocouple non inclus. 70 valables pour les condensateurs à couches (absorption diélectrique négligeable). ** En mode de sélection manuelle du calibre, la précision des calibres 500,0 µF, 5,000 mF et 25,00 mF n'est pas spécifiée en dessous de 45,0 µF, 0,450 mF et 4,50 mF respectivement. DM-860A Précision (suite) Fréquence — Niveau de ligne Plage : 5,000 Hz à 200,00 kHz Précision : ± (0,02 % + 4 chiffres) Calibre fonction AC 500 mV 5V 50 V 500 V 1000 V VFD 5 V VFD 50 V VFD 500 V Sensibilité (eff. sinusoïdal) 100 mV 0,5 V 5V 50 V 500 V 0,5 V à 2 V* 5 V à 20 V* 50 V à 200 V* Plage 10 Hz à 200 kHz 10 Hz à 100 kHz 10 Hz à 10 kHz Calibre Sensibilité fonction AC (eff. sinusoïdal) 500 µA 50 µA 5000 µA 500 µA 50 mA 5 mA 500 mA 50 mA 5A 1A 10 A 10 A Plage 10 Hz à 10 kHz 10 Hz à 3 kHz 10 Hz à 440 Hz   * La sensibilité VFD décroît linéairement de 10 % du calibre à 200 Hz à 40 % du calibre à 440 Hz. Fréquence — Niveau logique Plage : 5,000 Hz à 2,0000 MHz Précision : ± (0,002 % + 4 chiffres) Sensibilité : Signal carré 2,5 Vp Coefficient d'utilisation (%) Plage : 0,1 % à 99,99 % Précision : ± (3 chiffres/kHz + 2 chiffres) Fréquence d'entrée : 5 Hz à 500 kHz, famille de circuits logiques de 5 V Contrôle de diode Calibre de mesure : 2,0000 V Intensité de contrôle (type) : 0,4 mA Tension en circuit ouvert : < 3,0 VDC Précision : ± (1 % + 0,0001 V) Continuité Seuil de tonalité : Entre 20 Ω et 200 Ω Temps de réponse : < 100 µs dBm La plage et la fréquence dépendent de la fonction de tension AC utilisée et de l'impédance de référence sélectionnée. Impédance de référence sélectionnable : 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200 Ω Saisie de crête (tension et intensité) pour crêtes de durée > 0,8 ms Précision : Précision indiquée + 100 chiffres Résolution 5000 chiffres 71 Caractéristiques techniques Affichage : cristaux liquides (LCD) Mode normal : 50 000 points Mode haute résolution : 500 000 points Fréquence : 99 999 points Graphique à barres 41 segments Polarité : automatique Impédance d’entrée : 10 MΩ, 60 pF nominal (80 pF pour les calibres de 500 mV). Fréquence d’échantillonnage : Mode 50 000 points : 5 par seconde (nominal) Mode 500 000 points : 1,25 par seconde (nominal) Graphique à barres : 60 par seconde Coefficient de température : nominal 0,15 x (précision) par °C en dessous de 18 °C de 0 °C à 18 °C (32 °F à 64 °F) ou au-dessus de 28 °C de 28 °C à 40 °C (82 °F à 104 °F) ou autrement indiqué Mise hors tension automatique intelligente : au bout de 17 minutes d'inactivité Indicateur de décharge des piles : en dessous de 7 V environ Élimination du bruit* : Taux d’élimination du mode normal > 60 dB à 50 Hz et 60 Hz lors de la mesure de tension continue Taux d’élimination du mode commun > 90 dB de 0 Hz à 60 Hz lors de la mesure de tension alternative Taux d’élimination du mode normal > 120 dB à 50 Hz et 60 Hz lors de la mesure de tension continue Conditions d’utilisation : 0 °C à 31 °C (32 °F à 88 °F), 0 % à 80 % d’humidité relative 31 °C à 45 °C (88 °F à 113 °F), l'humidité relative décroît linéairement de 80 % à 50 % (sans condensation) Altitude : 2 000 m au maximum Utilisation à l’intérieur uniquement Degré de pollution : 2 Conditions d’entreposage : -20 °C à 60 °C (-4 °F à 140 °F), 0 % à 80 % d’humidité relative (sans condensation) Enlever la pile Pile : pile 9 V (NEDA 1604, JIS 006P ou IEC 6F) C.E.M. : conforme à EN61326-1:2006 Dans un champ RF de 3 V/m : Fonction de capacité non spécifiée Autres fonctions : précision totale = précision indiquée + 1000 chiffres Performances au-dessus de 3 V/m non spécifiées * L'élimination du bruit est la capacité de rejeter des signaux indésirables, ou bruit. • Les tensions de mode normal sont des signaux alternatifs pouvant fausser des mesures en courant continu. Le TRMN (taux de réjection en mode normal) est une mesure de la capacité à filtrer ces signaux. • Les tensions de mode commun sont des signaux présents aux bornes d'entrée COM et +, par rapport à la terre, pouvant provoquer des sautes ou un décalage de l'affichage des mesures de tension. Le TRMC (taux de réjection en mode commun) est une mesure de la capacité à filtrer ces signaux. 72 DM-860A Caractéristiques techniques (suite) Sécurité : Double isolation conformément à CEI/UL/EN61010-1 Éd. 3.0, CEI/EN61010-2-030 Éd. 1.0, CEI/EN61010-2-033 Éd. 1.0, CEI/UL/EN61010-031 Éd. 1.1 et CAN/CSA-C22.2 No. 61010-1-12 Éd. 3.0 selon CAT IV 1 000 V CA/CC. Protection contre les surcharges : V : 1 100 V CC/CA rms A : Fusible F, 11 A/1 000 V, valeur d’interruption nominale 20 kA, 13/32 po x 1,5 po µA et mA : Fusible F, 0,44 A/1 000 V, valeur d’interruption nominale 10 kA, 13/32 po x 1-3/8 po. mV, Ω et autres fonctions : 1 000 V CC/CA rms DIRECTIVES CENELEC : Ces instruments sont conformes aux directives CENELEC 2006/95/CE, relative à la basse tension, et 2004/108/CE, relative à la compatibilité électromagnétique Catégories de mesure Ces définitions sont dérivées des normes internationales sur la sécurité pour la c­ oordination de l’isolation telle qu’elle s’applique à la mesure, au contrôle et à l’équipement de laboratoire. Ces catégories de mesure sont expliquées plus en détail par la Commission électrotechnique internationale ; se reporter à l’une de ces deux publications : IEC 61010-1 ou IEC 60664. Catégorie de mesure I Niveau de signal. Pièces ou équipement électronique et de télécommunication. Par exemple, les circuits électroniques protégés contre les courants transitoires, dans les photocopieurs et les modems. Catégorie de mesure II Niveau local. Appareils, équipement portatif et les circuits dans lesquels ils sont branchés. Par exemple, les appareils d’éclairage, les téléviseurs et les dérivations. Catégorie de mesure III Niveau de distribution. Les machines installées en permanence et les circuits auxquels elles sont câblées. Par exemple, les systèmes de convoyeurs et les panneaux de disjoncteurs principaux du système électrique d’un édifice. Catégorie de mesure IV Niveau d’alimentation principal. Lignes surélevées et autres systèmes de câbles. Par exemple, les câbles, les compteurs, les transformateurs et autres équipements extérieurs appartenant aux fournisseurs en électricité. Déclaration de conformité Greenlee Tools, Inc. est certifiée selon ISO 9001:2008 pour nos Systèmes de gestion de la qualité. L’instrument ci-inclus a été vérifié et/ou étalonné avec des moyens de mesure raccordés aux étalons du National Institute of Standards and Technology (NIST). 73 Entretien Risques de décharge électrique : Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension. L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : Les fusibles forment une partie intégrante du système de protection de surtension. Lorsqu’un fusible doit être remplacé, consulter les caractéristiques techniques pour connaître le type, la taille et la capacité requis. L’utilisation de tout autre type de fusible annule l’étalonnage de protection contre la surtension de l’appareil. L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles. Changer la pile 1. Débrancher l’appareil du circuit. Mettre l’appareil hors tension (OFF). 2. Ôter les deux vis du couvercle d’accès à la pile et enlever le couvercle. 3. Changer la pile en veillant à respecter la polarité. Changer les fusibles 1. Débrancher l’appareil du circuit. Mettre l’appareil hors tension (OFF). 2. Ôter les deux vis du couvercle d’accès à la pile et enlever le couvercle. 3. Dévisser les deux vis à l’intérieur du compartiment de pile et les deux vis au dos du boîtier. 4. Enlever le dos du boîtier et changer les fusibles. 5. Aligner les deux moitiés de l’appareil et les joints en caoutchouc. 6. S’assurer que le sélecteur est dans sa position d’origine afin de s’aligner correctement avec le commutateur interne. 7. Remettre le couvercle et les vis en place. Nettoyage et entreposage Nettoyer régulièrement le boîtier avec un chiffon humide et un détergent doux. Ne pas utiliser de produits abrasifs ou de solvants. Si le multimètre doit rester inutilisé pendant des durées de plus de 60 jours, sortir la pile et l’entreposer séparément. 74 DM-860A 75 Lifetime Limited Warranty Greenlee Tools, Inc. warrants to the original purchaser of these goods for use that these p­ roducts will be free from defects in workmanship and material for their useful life, excepting normal wear and abuse. This warranty is subject to the same terms and conditions contained in Greenlee Tools, Inc.’s standard one-year limited warranty. For all Test Instrument repairs, contact Customer Service at 800-435-0786 and request a Return Authorization. For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote is available upon request. Note: Prior to returning any test instrument, please check replaceable b­ atteries or make sure the battery is at full charge. Garantía limitada válida durante la vida útil del producto Greenlee Tools, Inc. le garantiza al comprador original de estos bienes de uso, que los mismos estarán libres de defectos de materiales y fabricación durante su vida útil, excepto en el caso de que sean maltratados o hayan sufrido el deterioro normal. Esta garantía está sujeta a los mismos términos y condiciones de la garantía estándar limitada válida por un año, otorgada por Greenlee Tools, Inc. Para reparaciones de todo instrumento de verificación, comuníquese con el Departamento de Servicio al Cliente al 800-435-0786 y solicite una autorización de devolución. Puede obtener, previa solicitud, una cotización de precios de reparación para aquellos artículos que no están cubiertos bajo esta garantía (los que se han dejado caer o han sido maltratados). Aviso: Antes de devolver un instrumento de verificación, revise si las baterías están bajas y es necesario reemplazarlas. Garantie à vie limitée La société Greenlee Tools, Inc. garantit à l’acheteur d’origine de ces produits que ces derniers ne comportent aucun défaut d’exécution ou de matériau pour la durée de leur vie utile, sauf l’usure normale. Cette garantie est assujettie aux mêmes conditions que celles contenues dans les modalités et conditions de la garantie limitée standard d’un an de Greenlee Tools, Inc. Pour toutes les réparations d’instruments de mesure, appeler le service après vente au 800 435-0786 et demander une autorisation de retour. Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil tombe, s’il est soumis à un usage abusif, etc.), une soumission pour le prix de réparation sera présentée sur demande. Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier les piles remplaçables ou vous assurer que la batterie est ­complètement chargée. www.greenlee.com 4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070 An ISO 9001 Company • ©2019 Greenlee Tools, Inc. USA Tel: 800-435-0786 Fax: 800-451-2632 Canada Tel: 800-435-0786 Fax: 800-524-2853 International Tel: +1-815-397-7070 Fax: +1-815-397-9247
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Greenlee DM-860A Digital Multimeter Manual de usuario

Categoría
Medir, probar
Tipo
Manual de usuario
Este manual también es adecuado para