Digital clamp meter
ENGLISH
MGL EUMAN, S.L.
Parque Empresarial de Argame,
C/Picu Castiellu, Parcelas i-1 a i-4
E-33163 Argame, Morcín
Asturias, España, (Spain)
See the full
instruction manual:
SAFETY INFORMATION
The digital clamp meter has been designed according to IEC1010– 1 and IEC1010–2–032
concerning safety requirements for electrical measuring instruments and hand – held current
clamps with overvoltage category 1000V CAT II 600V CAT III and pollution 2.
SAFETY SYMBOLS
Symbol Meaning
Important safety information, refer to the operating manual.
Dangerous voltage may be present.
Earth ground.
Double insulation ( Protection class 1000V CAT II 600V CAT III ).
SAFETY PRECAUTIONS
Follow all safety and operating instructions to ensure maximum personal safety during the
operation and to ensure the meter is used safely and is kept in good operating condition.
• Read these operating instructions thoroughly and completely before operating your meter.
Pay particular attention to WARNINGS, which will inform you of potentially dangerous
procedures. The instructions in these warnings must be followed.
• Always inspect your meter and test leads for any sign of damage or abnormality before
every use. If any abnormal conditions exist (i.e. broken test leads, cracked cases, display
not reading, etc.), do not attempt to take any measurements.
• Do not expose the instrument to direct sunlight, extreme temperature or moisture.
• Never ground yourself when taking electrical measurements. Do not touch exposed metal
pipes, outlets, xtures, etc., which might be at ground potential. Keep your body isolated
from ground by using dry clothing; rubber shoes, rubber mat, or any approved insulating
material.
• You always are careful when working with voltages above 60V dc or 30V ac rms. Keep
ngers behind the probe barriers while measuring.
• Never use the meter to measure voltages that might exceed the maximum allowable input
value of any function.
• Never touch exposed wiring, connections or any live circuit when attempting to take
measurements.
MAINTENANCE
• Before opening the case, always disconnect test leads from all energized circuits.
• Never use the meter unless the back cover is in place and fastened completely.
• Do not use abrasives or solvents on the meter. To clean it using a damp cloth and mild
detergent only.
• Qualied and trained service technicians should only perform calibration and repair of
the meter.
• Do not attempt calibration or service unless trained and another person capable of
rendering rst aid and resuscitation is present.
REPLACING THE BATTERY
WARNING
Before attempting to open the case of battery, always be sure that test leads have been
disconnected from measurement circuits. Close case and tighten screws completely before
using the meter to avoid electrical shock hazard.
If , appears on display, it indicates that the battery should be replaced. Use the following
procedure to replacing the battery:
• Disconnect test leads from any live source and remove the test leads from the input
terminals of the meter. Push the POWER switch to OFF,
• The battery cover is secured to the bottom case by a screw. Using a screwdriver, remove
the screw from the battery cover and remove the battery cover.
• Remove battery and replace with a new equivalent 9 volt battery.
• Replace the battery cover and reinstall the screw.
ACCESSORIES
Summary instruction manual
Set of test leads
Gift box
9 volt battery. NEDA 1604 6F22 006P type
ENGLISH
APAC: MGL GLOBAL SOLUTIONS LTD
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
AMERICAS: MGL AMERICA, LLC.
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
28217 USA
Tel: +1 833 533-5899
US West Coast: 760 Challenger Street.
Brea, California 92821 USA
Tel: +1 310-728-6220
www.mgl-intl.com