White Rodgers 1F95-1277 Guía de instalación

Categoría
Termostatos
Tipo
Guía de instalación
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W/E
G
C
-
W2
No
Output
24 V A C
(Hot)
Cool
DC
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
T e mp-
erature
Sensor
Y2 Y
RC
S
6
L
{
T o Remote T e mperature Sensor
24 V A C
(Hot)
Heat
24 V A C
Com-
mon
(option-
al) *
CLASS II
TRANSFORMER
120VAC
HOT
24VAC
NEUTRAL
HEATING
COOLING
Ener-
gized
in Heat
Mode
Energiz-
ed in
Cool &
Off
Mode
Cool
mode
2nd
Stage
(Com-
pressor)
Cool
Mode
1st
Stage
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Cool &
for Heat
(if ELE
is sel-
ected)
Heat
Mode
2nd
Stage
No
Output
Heat
Mode
1st
Stage
Ener-
gized
on call
for
Heat
Power
Closed
Conn-
ection
for
3-wire
zone
valve
Fault
Indicator
or
System
Malfunc-
tion
Switch
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
Comfort
Alert II module
or similar
malfunction
module
Single
Stage 1
(SS1)
Multi-
Stage 2
(MS2)
Energiz-
ed in
Cool &
Off
Mode
Ener-
gized
in Heat
Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W/E
G
C
-
W2
Jumper
No
Output
Cool
Mode
1st
Stage
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Cool &
for Heat
(if ELE
is sel-
ected)
24 V A C
(Hot)
Cool
DC
supply
voltage
to re-
mote
T e mp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
T e mp-
erature
Sensor
Heat
Mode
1st
Stage
Power
Closed
Conn-
ection
for
3-wire
zone
valve
Fault
Indicator
or
System
Malfunc-
tion
Switch
Y2 Y
RC
S
6
L
{
T o Remote T e mperature Sensor
Cool
mode
2nd
Stage
(Com-
pressor)
24 V A C
(Hot)
Heat
24 V A C
Com-
mon
(option-
al) *
Heat
Mode
2nd
Stage
No
Output
Ener-
gized
on call
for
Heat
Comfort
Alert II module
or similar
malfunction
module
Heat
Pump 1
(HP1)
Heat
Pump 2
(HP2)
Energiz-
ed in
Cool
& Off
Mode
Energiz-
ed in
Heat/
Emer-
gency
Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W/E
Jumper
G
C
-
W2
Jumper
No
Output
1st
Stage
Heat &
Cool
(Com-
pressor)
**
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Heat or
Cool
24 V A C
(Hot)
Cool
DC
supply
voltage
to re-
mote
T e mp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
T e mp-
erature
Sensor
Auxil-
iary &
Emer-
gency
Heat
1st
Stage
Power
Closed
Conn-
ection
for
3-wire
zone
valve
Fault
Indicator
or
System
Malfunc-
tion
Switch
Y2 Y
RC
S
6
L
{
T o Remote T e mperature Sensor
2nd
Stage
Heat/
Cool
(Com-
pressor)
24 V A C
(Hot)
Heat
24 V A C
Com-
mon
(option-
al) *
(Dual
Fuel
disabled)
Emer-
gency
heat
2nd stage
(Dual
Fuel
enabled)
Auxiliary
& Emer-
gency
heat
2nd stage
Comfort
Alert II module
or similar
malfunction
module
www.white-rodgers.com
Big Blue Universal Thermostat
Wiring Diagrams for 1F95-1277
PART NO. 37-6808D
Replaces 37-6808C
0904
Single Stage, Multi-Stage, Heat Pump
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Printed In U.S.A.
Heat Pump Connections
If you do not have a heat pump system, refer to gures 2 & 3.
Refer to equipment manufacturers' instructions for specic system
wiring information.
You can congure the thermostat for use with the following heat
pump systems.
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas
or electric backup.
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two com-
pressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for proper
thermostat conguration.
NOTE: If your system does not
provide an E connection, jumper W2
to W/E to use the Auxiliary Heat in the
Emergency Mode.
* 24 VAC common connection
optional for system operation.
Required for fault or malfunction indi-
cation, remote temperature sensor, or
for continuous backlight operation.
** Dual fuel option de-energizes
compressor when auxiliary heat is
energized.
Figure 1 – Heat Pump Systems
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers' instructions for specic system
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can congure the thermostat for use with the following fossil fuel
systems:
SINGLE STAGE (SS 1) gas, oil or electric.
MULTI-STAGE (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper
thermostat conguration.
Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer
Figure 3 – Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers
* 24 VAC common connection
optional for system operation.
Required for fault or malfunc-
tion indication, remote temper-
ature sensor, or for continuous
backlight operation.
NOTE: If continuous backlight or hardwired
power input are desired but do not function
in both HEAT and COOL modes, cut the
heating transformer 24V wires and tape off.
Connect the neutral circuit disconnected
from the heating transformer to the neutral
circuit of the cooling transformer. Discon-
nect the wire to the RH terminal and install
a jumper between RH and RC. Depending
on the system requirements, replace the
cooling transformer with a 75VA class II
transformer if needed.
O
RH
+
B
W/E
G
C
-
W2
Y2 Y
RC
S
6
L
{
Al sensor de temperatura remoto
CLASS II
TRANSFORMER
120VCA
VIVO
24VCA
NEUTRO
CALEFACCIÓN
ENFRIAMIENTO
Una
sola
etapa 1
(SS1)
Multi-
etapa 2
(MS2)
Ener-
gizado
en el
modo
Cool y
Off
Ener-
gizado
en el
modo
Heat
Sistema
TRANSFORMADOR
DE CLASE II
VIVO
24VCA
NEUTRO
120VCA
No
salida
Modo
Cool
1° etapa
(com-
presor)
Sopla-
dor/Ven-
tilador
circula-
dor
energi-
zado en
llamada
de calor
o frío (si
se sele-
cciona
ELE)
24 VCA
(vivo)
Frío
Voltaje
de ali-
menta-
ción
CC al
sensor
de tem-
peratu-
ra
remoto
Señal
de
sensor
de
tempe-
ratura
remoto
Retorno
de CC
al
sensor
de tem-
peratura
remoto
Modo
Heat
1° etapa
Cone-
xión
cerrada
de ali-
menta-
ción
para
válvula
zoni-
ficada
de 3
cables
Indicador
de falla o
inte-
rruptor
de des-
perfecto
del
sistema
Modo
Cool
2° etapa
(com-
presor)
24 VCA
(vivo)
Calor
24 VCA
Neutro
(opcio-
nal) *
Modo
Heat
2° etapa
No
salida
Ener-
gizado
en
llamada
de calor
Módulo de alerta
de confort II o
módulo de
desperfecto similar
Una
sola
etapa 1
(SS1)
Multi-
etapa 2
(MS2)
Ener-
gizado
en el
modo
Cool y
Off
Ener-
gizado
en el
modo
Heat
Sistema
O
RH
+
B
TRANSFORMADOR
DE CLASE II
VIVO
24VCA
NEUTRO
120VC
A
W/E
G
C
-
W2
Puente
No
salida
Modo
Cool
1° etapa
(com-
presor)
Sopla-
dor/Ven-
tilador
circula-
dor
energi-
zado en
llamada
de calor
o frío (si
se sele-
cciona
ELE)
24 VCA
(vivo)
Frío
Voltaje
de ali-
menta-
ción
CC al
sensor
de tem-
peratu-
ra
remoto
Señal
de
sensor
de
tempe-
ratura
remoto
Retorno
de CC
al
sensor
de tem-
peratura
remoto
Modo
Heat
1° etapa
Cone-
xión
cerrada
de ali-
menta-
ción
para
válvula
zoni-
ficada
de 3
cables
Indicador
de falla o
inte-
rruptor
de des-
perfecto
del
sistema
Y2 Y
RC
S
6
L
{
Al sensor de temperatura remoto
Modo
Cool
2° etapa
(com-
presor)
24 VCA
(vivo)
Calor
24 VCA
Neutro
(opcio-
nal) *
Modo
Heat
2° etapa
No
salida
Ener-
gizado
en
llamada
de calor
Módulo de alerta
de confort II o
módulo de
desperfecto similar
Bomba
de calor
1 (HP1)
Ener-
gizado
en el
modo
Cool y
Off
Ener-
gizado
en el
modo
Heat/
Emer-
gency
Sistema
O
RH
+
B
TRANSFORMADOR
DE CLASE II
VIVO
24 VCA
NEUTRO
120VCA
W/E
Puente
G
C
-
W2
Puente
No
salida
Calor/
Frío 1°
etapa
(com-
pre-
sor)**
Sopla-
dor/
Venti-
lador
circula-
dor
energi-
zado en
llamada
de calor
o frío
24 VCA
(vivo)
Frío
Voltaje
de ali-
menta-
ción
CC al
sensor
de tem-
peratu-
ra
remoto
Señal
de
sensor
de
tempe-
ratura
remoto
Retorno
de CC
al
sensor
de tem-
peratura
remoto
Auxi-
liary y
Emer-
gency
Heat
etapa
Cone-
xión
cerrada
de ali-
menta-
ción
para
válvula
zoni-
ficada
de 3
cables
Indicador
de falla o
inte-
rruptor
de des-
perfecto
del
sistema
Y2 Y
RC
S
6
L
{
Al sensor de temperatura remoto
Calor/
Frío 2°
etapa
(com-
presor)
24 VCA
(vivo)
Calor
24 VCA
Neutro
(opcio-
nal) *
(Doble
combustible
desacti-
vado)
Emergency
heat 2°
etapa
(Doble
combustible
activado)
Auxiliary y
Emergency
heat 2°
etapa
Módulo de alerta
de confort II o
módulo de
desperfecto similar
Bomba
de calor
2 (HP2)
www.white-rodgers.com
Diagramas de conexiones del termostato
universal Big Blue para 1F95-1277
N° DE PIEZA 37-6808D
Reemplaza 37-6808C
0904
Una sola etapa, multietapa, bomba de calor
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
Printed In U.S.A.
Conexiones de la bomba de calor
Si no tiene un sistema de bomba de calor, reérase a las guras 2 y 3.
Reérase a las instrucciones del fabricante del equipo para ver
información más especíca sobre las conexiones.
Puede congurar el termostato para utilizarlo con los siguientes
sistemas de bombas de calor.
BOMBA DE CALOR TIPO 1 (HP 1). Sistema de compresor de una
sola etapa; sistema auxiliar de gas o eléctrico.
BOMBA DE CALOR TIPO 2 (HP 2). Sistema de compresor
multietapa o de dos compresores con sistema de gas o eléctrico
auxiliar. Después de conectar el termostato, vea en la sección
INSTALLER CONFIGURATION cómo congurarlo correctamente.
NOTA: Si su sistema no cuenta con
una conexión E, puente W2 con W/E
para utilizar el calor auxiliar en el
modo Emergency.
* Conexión neutra de 24 VCA
opcional para el funcionamiento del
sistema.
Requerido para la indicación de falla
o desperfecto, sensor de temperatura
remoto o para el funcionamiento
continuo de la luz de fondo.
** La opción de doble combustible
desenergiza el compresor
cuando se energiza
el calor auxiliar.
Figura 1 – Sistemas de bombas de calor
Conexiones de una sola etapa y multietapa
Reérase a las instrucciones del fabricante del equipo para ver
información más especíca sobre las conexiones.
Este termostato está diseñado para operar un sistema de un solo
transformador o de dos transformadores.
Puede congurar el termostato para utilizarlo con los siguientes
sistemas de combustible fósil:
UNA SOLA ETAPA (SS 1) gas, aceite o eléctrico.
MULTIETAPA (MS 2) gas, aceite o eléctrico.
Después de conectar el termostato, vea en la sección INSTALLER
CONFIGURATION cómo congurarlo correctamente.
Figura 2 – Sistema de una sola etapa o multietapa (sin bomba de calor) con un solo transformador
Figura 3 – Sistema de una sola etapa o multietapa (sin bomba de calor) con dos transformadores
* Conexión neutra de 24 VCA
opcional para el
funcionamiento del sistema.
Requerido para la indicación
de falla o desperfecto, sensor
de temperatura remoto o para
el funcionamiento continuo de
la luz de fondo.
NOTA: Si desea iluminación constante
de la luz de fondo o alimentación de
entrada con cableado interno pero no
desea que el sistema funcione en los
modos HEAT y COOL, corte los cables
de 24 V del transformador de calefacción
y encíntelos. Conecte el circuito neutro
desconectado del transformador de
calefacción al circuito neutro del
transformador de enfriamiento.
Desconecte el cable a la terminal RH
e instale un puente entre RH y RC.
Según los requisitos del sistema, cambie
el transformador de enfriamiento por un
transformador de 75 VA clase II si es
necesario.

Transcripción de documentos

Big Blue Universal Thermostat Wiring Diagrams for 1F95-1277 Single Stage, Multi-Stage, Heat Pump Heat Pump Connections If you do not have a heat pump system, refer to figures 2 & 3. Refer to equipment manufacturers' instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump systems. Figure 1 – Heat Pump Systems { O Y2 RC G Y NOTE: If your system does not provide an E connection, jumper W2 to W/E to use the Auxiliary Heat in the Emergency Mode. To Remote Temperature Sensor Jumper B HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup. HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup. After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration. RH C S + - Jumper W/E W2 6 L Power Closed Connection for 3-wire zone valve Fault Indicator or System Malfunction Switch * 24 VAC common connection optional for system operation. Required for fault or malfunction indication, remote temperature sensor, or for continuous backlight operation. System Heat Pump 1 (HP1) Heat Pump 2 (HP2) (Dual Fuel disabled) Blower/ DC DC No Emer1st Circulasupply Remote Return gency Output 24 VAC EnergizAuxilStage tor Fan 24 VAC 24 VAC ComEnergizvoltage Temp- to heat ed in iary & Heat & Energiz2nd stage ed in to reRemote erature mon (Hot) Heat/ (Hot) EmerCool ed on Sensor Temp- (Dual (option- mote Heat Emer- Cool Cool gency (Com2nd call for Temp- signal erature Fuel al) * gency & Off Stage enabled) Heat pressor) Heat or Mode erature Sensor Auxiliary 1st Mode Heat/ ** Cool Sensor & Emer- Stage Cool gency (Comheat pressor) 2nd stage ** Dual fuel option de-energizes compressor when auxiliary heat is energized. Comfort Alert II module or similar malfunction module NEUTRAL 120VAC 24VAC HOT Single Stage and Multi-Stage Connections CLASS II TRANSFORMER Refer to equipment manufacturers' instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or twotransformer system. You can configure the thermostat for use with the following fossil fuel systems: Single stage (SS 1) gas, oil or electric. Multi-stage (MS 2) gas, oil or electric. After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration. Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer { To Remote Temperature Sensor Jumper B O Y2 RC G Y RH C + S - W2 W/E 24 VAC Common (optional) * DC supply voltage to remote Temperature Sensor Remote Temperature Sensor signal DC Return to Remote Temperature Sensor No Output Energized on call for Heat Heat Mode 2nd Stage Heat Mode 1st Stage 6 L Power Closed Connection for 3-wire zone valve Fault Indicator or System Malfunction Switch System Single Stage 1 (SS1) MultiStage 2 (MS2) Energized in Heat Mode No Output Energized in Cool & Cool Off mode Mode 2nd Stage (Compressor) Cool Mode 1st Stage (Compressor) Blower/ Circulator Fan Energiz24 VAC 24 VAC ed on (Hot) (Hot) call for Heat Cool Cool & for Heat (if ELE is selected) Comfort Alert II module or similar malfunction module * 24 VAC common connection optional for system operation. Required for fault or malfunction indication, remote temperature sensor, or for continuous backlight operation. NEUTRAL 120VAC 24VAC HOT CLASS II TRANSFORMER Figure 3 – Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers { To Remote Temperature Sensor B O Y2 Y G RC RH C + S - W2 W/E 24 VAC Common (optional) * DC supply voltage to remote Temperature Sensor Remote Temperature Sensor signal DC Return to Remote Temperature Sensor No Output Energized on call for Heat Heat Mode 2nd Stage Heat Mode 1st Stage 6 L Power Closed Connection for 3-wire zone valve Fault Indicator or System Malfunction Switch System Single Stage 1 (SS1) MultiStage 2 (MS2) No Cool Energiz- Output Mode Enered in 1st gized Cool & Stage in Heat Cool Off (ComMode mode Mode pressor) 2nd Stage (Compressor) Blower/ Circulator Fan Energiz24 VAC 24 VAC ed on (Hot) call for (Hot) Heat Cool & Cool for Heat (if ELE is selected) Comfort Alert II module or similar malfunction module NOTE: If continuous backlight or hardwired power input are desired but do not function in both HEAT and COOL modes, cut the heating transformer 24V wires and tape off. Connect the neutral circuit disconnected from the heating transformer to the neutral circuit of the cooling transformer. Disconnect the wire to the RH terminal and install a jumper between RH and RC. Depending on the system requirements, replace the cooling transformer with a 75VA class II transformer if needed. NEUTRAL 24VAC NEUTRAL 120VAC 120VAC HOT 24VAC COOLING CLASS II TRANSFORMER HOT HEATING CLASS II TRANSFORMER White-Rodgers is a division of Emerson Electric Co. www.white-rodgers.com www.white-rodgers.com Printed In U.S.A. PART NO. 37-6808D Replaces 37-6808C 0904 Diagramas de conexiones del termostato universal Big Blue para 1F95-1277 Una sola etapa, multietapa, bomba de calor Conexiones de la bomba de calor Si no tiene un sistema de bomba de calor, refiérase a las figuras 2 y 3. Refiérase a las instrucciones del fabricante del equipo para ver información más específica sobre las conexiones. Puede configurar el termostato para utilizarlo con los siguientes sistemas de bombas de calor. BOMBA DE CALOR TIPO 1 (HP 1). Sistema de compresor de una sola etapa; sistema auxiliar de gas o eléctrico. BOMBA DE CALOR TIPO 2 (HP 2). Sistema de compresor multietapa o de dos compresores con sistema de gas o eléctrico auxiliar. Después de conectar el termostato, vea en la sección INSTALLER CONFIGURATION cómo configurarlo correctamente. Figura 1 – Sistemas de bombas de calor NOTA: Si su sistema no cuenta con una conexión E, puente W2 con W/E para utilizar el calor auxiliar en el modo Emergency. { Al sensor de temperatura remoto Puente B O Y2 RC G Y RH C S + - Puente W/E W2 6 L * Conexión neutra de 24 VCA opcional para el funcionamiento del sistema. Requerido para la indicación de falla o desperfecto, sensor de temperatura remoto o para el funcionamiento continuo de la luz de fondo. Sistema Bomba de calor 1 (HP1) Energizado en el modo Bomba Heat/ de calor Emer2 (HP2) gency No salida Energizado en el modo Cool y Off Calor/ Frío 2° etapa (compresor) Soplador/ Ventilador circula- 24 VCA 24 VCA (vivo) (vivo) dor Calor energi- Frío zado en llamada de calor o frío Calor/ Frío 1° etapa (compresor)** Voltaje de alimentación CC al sensor de temperatura remoto 24 VCA Neutro (opcional) * (Doble combustible desactivado) Emergency heat 2° etapa Retorno de CC al sensor de temperatura remoto Señal de sensor de temperatura remoto (Doble combustible activado) Auxiliary y Emergency heat 2° etapa Conexión cerrada Auxi- de aliliary y mentaEmer- ción gency para válvula Heat zoni1° etapa ficada de 3 cables Indicador de falla o interruptor de desperfecto Módulo de alerta del de confort II o sistema módulo de desperfecto similar NEUTRO 120VCA 24 VCA VIVO Conexiones de una sola etapa y multietapa ** La opción de doble combustible desenergiza el compresor cuando se energiza el calor auxiliar. TRANSFORMADOR DE CLASE II Refiérase a las instrucciones del fabricante del equipo para ver información más específica sobre las conexiones. Este termostato está diseñado para operar un sistema de un solo transformador o de dos transformadores. Puede configurar el termostato para utilizarlo con los siguientes sistemas de combustible fósil: UNA SOLA ETAPA (SS 1) gas, aceite o eléctrico. MULTIETAPA (MS 2) gas, aceite o eléctrico. Después de conectar el termostato, vea en la sección INSTALLER CONFIGURATION cómo configurarlo correctamente. Figura 2 – Sistema de una sola etapa o multietapa (sin bomba de calor) con un solo transformador { Al sensor de temperatura remoto Puente B O Y2 Y G RC RH C S + - W/E W2 6 L * Conexión neutra de 24 VCA opcional para el funcionamiento del sistema. Requerido para la indicación de falla o desperfecto, sensor de temperatura remoto o para el funcionamiento continuo de la luz de fondo. Sistema Una sola etapa 1 (SS1) Energizado en el modo Heat Multietapa 2 (MS2) Energizado en el modo Cool y Off Soplador/VenNo tilador Modo circulasalida Cool dor 1° etapa energi(com- zado en Modo presor) llamada Cool de calor 2° etapa o frío (si (comse selepresor) cciona ELE) Conexión Voltaje Retorno No cerrada de ali- Señal de CC salida de alial menta24 VCA 24 VCA 24 VCA menta- de sensor sensor (vivo) Neutro ción ción (vivo) CC al de temde Calor (opciopara Frío sensor tempe- peratura Modo Modo nal) * válvula de tem- ratura remoto Heat Heat zoniperatu- remoto 2° etapa 1° etapa ficada ra de 3 remoto cables Energizado en llamada de calor Indicador de falla o interruptor de desperfecto Módulo de alerta del de confort II o sistema módulo de desperfecto similar NEUTRO 120VCA 24VCA VIVO TRANSFORMADOR DE CLASE II Figura 3 – Sistema de una sola etapa o multietapa (sin bomba de calor) con dos transformadores { Al sensor de temperatura remoto B O Y2 G Y RC RH C + S - W2 W/E 6 L Sistema Una sola etapa 1 (SS1) Multietapa 2 (MS2) Energizado en el modo Heat Energizado en el modo Cool y Off No salida Modo Cool 2° etapa (compresor) Modo Cool 1° etapa (compresor) Soplador/Ventilador circulador 24 VCA 24 VCA energi(vivo) (vivo) zado en Calor llamada Frío de calor o frío (si se selecciona ELE) Voltaje de ali24 VCA mentaNeutro ción (opcio- CC al sensor nal) * de temperatura remoto Señal de sensor de temperatura remoto Retorno de CC al sensor de temperatura remoto Conexión cerrada de alimentación para Modo Modo válvula Heat Heat zoni2° etapa 1° etapa ficada de 3 cables No salida Energizado en llamada de calor Indicador de falla o interruptor de desperfecto Módulo de alerta del de confort II o sistema módulo de desperfecto similar NOTA: Si desea iluminación constante de la luz de fondo o alimentación de entrada con cableado interno pero no desea que el sistema funcione en los modos HEAT y COOL, corte los cables de 24 V del transformador de calefacción y encíntelos. Conecte el circuito neutro desconectado del transformador de calefacción al circuito neutro del transformador de enfriamiento. Desconecte el cable a la terminal RH e instale un puente entre RH y RC. Según los requisitos del sistema, cambie el transformador de enfriamiento por un transformador de 75 VA clase II si es necesario. NEUTRO 120VCA 120VCA 24VCA NEUTRO VIVO 24VCA ENFRIAMIENTO VIVO TRANSFORMADOR DE CLASE II CALEFACCIÓN CLASS II TRANSFORMER White-Rodgers is a division of Emerson Electric Co. www.white-rodgers.com www.white-rodgers.com Printed In U.S.A. N° DE PIEZA 37-6808D Reemplaza 37-6808C 0904