Ideal 30-103X Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

PowerPlug
®
Luminaire Disconnect -
Model 103 Installation Instructions:
To be sold only with installation instructions.
WARNING: This is a current rated device. Use in applications involving
amperage beyond its rating can be dangerous and cause electrical fires. Do not
exceed maximum current and voltage levels.
Instructions:
Conductor installation:
1. Wiring must comply with all applicable electrical codes.
2. Turn off power before removing or installing disconnect.
3. Strip wires to 3/8” (9,5 mm). 18 AWG can be
3/8” to 1/2” strip.
4. Grip load wires firmly and push conductors into
white cap ports. See load side diagrams at right for
proper wire insertion for ballast configurations.
5. Grip supply wires firmly and push conductors into ports opposite load wires. See line side
diagram at right for proper wiring configuration.
6. Use only one conductor per port and assure that no copper is exposed on any of the wires
inserted.
7. See disconnect de-mate/mate installation instructions below when replacing ballasts.
8. The wire insertion side of this product is listed for ONE TIME USE ONLY. DO NOT
REMOVE AND REPLACE WIRES.
DANGER
NEVER remove wires from product as contact with electricity can cause serious injury or
death. Shut off power at the circuit breaker or remove fuse when installing this product.
SAFETY NOTICE
Improperly installed electrical wiring can be dangerous and cause electrical fires. This product
must be used in accordance with the current rating and wire sizes listed. Consult local building
code before doing any electrical work.
PowerPlug
®
Luminaire Disconnect -
Model 103 Installation Instructions:
To be sold only with installation instructions.
WARNING: This is a current rated device. Use in applications involving
amperage beyond its rating can be dangerous and cause electrical fires. Do not
exceed maximum current and voltage levels.
Instructions:
Conductor installation:
1. Wiring must comply with all applicable electrical codes.
2. Turn off power before removing or installing disconnect.
3. Strip wires to 3/8” (9,5 mm). 18 AWG can be
3/8” to 1/2” strip.
4. Grip load wires firmly and push conductors into
white cap ports. See load side diagrams at right for
proper wire insertion for ballast configurations.
5. Grip supply wires firmly and push conductors into ports opposite load wires. See line side
diagram at right for proper wiring configuration.
6. Use only one conductor per port and assure that no copper is exposed on any of the wires
inserted.
7. See disconnect de-mate/mate installation instructions below when replacing ballasts.
8. The wire insertion side of this product is listed for ONE TIME USE ONLY. DO NOT
REMOVE AND REPLACE WIRES.
DANGER
NEVER remove wires from product as contact with electricity can cause serious injury or
death. Shut off power at the circuit breaker or remove fuse when installing this product.
SAFETY NOTICE
Improperly installed electrical wiring can be dangerous and cause electrical fires. This product
must be used in accordance with the current rating and wire sizes listed. Consult local building
code before doing any electrical work.
COPPER TO COPPER ONLY. Do not use on Aluminum. Temperature rating: 105°C (221°F)
maximum. Flame Rated UL94V-0.
This disconnect is rated for 600 Volts/6 Amps maximum.
Rated for a limited number of current-interrupting operations.
Wire Range Line Side (Orange) Load Side (White)
Solid: 12-18 AWG 18 AWG
Stranded: 12-14 AWG (19 Strand or less)
Stranded Tin Bonded: 12-14 AWG (19 Strand or less) 18 AWG
16 AWG (26 Strand or less) (16 Strand or less)
18 AWG (16 Strand or less)
Disconnect de-mate / mate installation
1. To de-mate, grasp disconnect at each end and pull apart to separate the disconnect halves.
Do NOT pull on wires.
2. To mate the disconnect, grasp each disconnect half, align halves, and push together.
IDEAL INDUSTRIES, INC.
1375 Park Avenue
Sycamore, IL 60178, U.S.A.
800-435-0705 Customer Assistance
www.idealind.com
ND
6847-7
Hot
BALLAST
BALLAST
BALLAST
BALLAST
Line Side (3 Ports)
(Orange Cap)
Load Side (6 Ports)
(White Cap)
Single Ballast
(Red)
Switchable/Step
Dimming
Full-Light Output
Neutral
Hot #2
(Red)
BALLAST
COPPER TO COPPER ONLY. Do not use on Aluminum. Temperature rating: 105°C (221°F)
maximum. Flame Rated UL94V-0.
This disconnect is rated for 600 Volts/6 Amps maximum.
Rated for a limited number of current-interrupting operations.
Wire Range Line Side (Orange) Load Side (White)
Solid: 12-18 AWG 18 AWG
Stranded: 12-14 AWG (19 Strand or less)
Stranded Tin Bonded: 12-14 AWG (19 Strand or less) 18 AWG
16 AWG (26 Strand or less) (16 Strand or less)
18 AWG (16 Strand or less)
Disconnect de-mate / mate installation
1. To de-mate, grasp disconnect at each end and pull apart to separate the disconnect halves.
Do NOT pull on wires.
2. To mate the disconnect, grasp each disconnect half, align halves, and push together.
IDEAL INDUSTRIES, INC.
1375 Park Avenue
Sycamore, IL 60178, U.S.A.
800-435-0705 Customer Assistance
www.idealind.com
ND
6847-7
Hot
BALLAST
BALLAST
BALLAST
BALLAST
Line Side (3 Ports)
(Orange Cap)
Load Side (6 Ports)
(White Cap)
Single Ballast
(Red)
Switchable/Step
Dimming
Full-Light Output
Neutral
Hot #2
(Red)
BALLAST
COBRE A COBRE ÚNICAMENTE. No use el producto en aluminio. Temperatura nominal: 105°
(221°F) máximo CLASIFICACIÓN DE LLAMA UL94V-0.
Este dispositivo de desconexión está especificado para 600 V / 6 A máximo.
Clasificado para un número limitado de operaciones de interrupción de corriente
Rango de cables Lado de la línea (anaranjado) Lado del balasto
Macizo: 12-18 AWG 18 AWG
Trenzado: 12-14 AWG (19 hilos o menos)
Trenzado estañado: 14 AWG (19 hilos o menos) 18 AWG
16 AWG (26 hilos o menos) (16 hilos o menos)
18 AWG (16 hilos o menos)
Instrucciones de desacoplamiento y acoplamiento del dispositivo de desconexión
1. Para desacoplar, tome el dispositivo de desconexión por ambos extremos y tire para separar
las mitades del mismo.
2. Para acoplar el dispositivo de desconexión, tome ambas mitades del mismo, alinéelas y
presiónelas para unirlas.
IDEAL INDUSTRIES, INC.
1375 Park Avenue
Sycamore, IL 60178, U.S.A.
800-435-0705 Asistencia al cliente
www.idealind.com
ND
6847-7
Calietne
Línea de Carga
(3 puertos)
(Tapa naranja)
Neutral
Caliente #2
(Rojo)
BALASTO
BALASTO
BALASTO
BALASTO
Lado de Carga (6 puertos)
(White Cap)
Balasto único
(Red)
Atenuador
conmutable/por
pasos
Salida de máxima
luz
BALASTO
Para vender únicamente con instrucciones de instalación.
ADVERTENCIA: Éste es un dispositivo especificado por corriente.
No exceda los niveles máximos de corriente y voltaje.
Instrucciones – Instalación de los conductores :
1. El cableado debe cumplir todos los códigos eléctricos aplicables.
2. Desconecte la alimentación eléctrica antes de quitar o
instalar el dispositivo seccionador.
3. Pele los cables 3/8” (9,5 mm). El cable 18 AWG se
puede pelar de 9,5 a 13 mm (3/8 a 1/2”).
4. Tome los cables de carga firmemente y empuje los
conductores para introducirlos en los orificios de conexión con tapas blancas. Vea los dia
gramas del lado de carga de la derecha para conocer la inserción correcta de los cables
correspondientes a las configuraciones de reactor (balasto).
5. Tome los cables de alimentación firmemente y empuje los conductores para introducirlos
en los orificios de conexión opuestos a los cables de carga. Vea el diagrama del lado de la
línea de la derecha para conocer la configuración correcta del cableado.
6. Use sólo un conductor por orificio y asegúrese de que no quede el cobre expuesto en
ninguno de los cables insertados.
7. Cuando reemplace los reactores, vea las instrucciones de desacoplamiento y acoplamiento
del dispositivo seccionador incluidas más abajo.
8. El lado de inserción de cables de este producto está especificado para USAR UNA SOLA
VEZ. NO RETIRE Y VUELVA A COLOCAR LOS CABLES.
PELIGRO
NUNCA retire los cables del producto, puesto que el contacto con la electricidad puede causar
graves lesiones o la muerte. Desconecte el suministro eléctrico en el disyuntor o quite el fusible
cuando vaya a instalar este producto.
AVISO SOBRE LA SEGURIDAD
El cableado eléctrico instalado incorrectamente puede ser peligroso y causar incendios eléctricos.
Este producto se debe usar de acuerdo con la especificación de corriente y los tamaños de cable
indicados. Consulte el código de construcción local antes de hacer un trabajo eléctrico.
PowerPlug
®
Conector acoplador para
accesorios luminosos - Model 103
Instrucciones Instalación:
PowerPlug
®
Conector acoplador para
accesorios luminosos - Model 103
Instrucciones Instalación:
Para vender únicamente con instrucciones de instalación.
ADVERTENCIA: Éste es un dispositivo especificado por corriente.
No exceda los niveles máximos de corriente y voltaje.
Instrucciones – Instalación de los conductores :
1. El cableado debe cumplir todos los códigos eléctricos aplicables.
2. Desconecte la alimentación eléctrica antes de quitar o
instalar el dispositivo seccionador.
3. Pele los cables 3/8” (9,5 mm). El cable 18 AWG se
puede pelar de 9,5 a 13 mm (3/8 a 1/2”).
4. Tome los cables de carga firmemente y empuje los
conductores para introducirlos en los orificios de conexión con tapas blancas. Vea los dia
gramas del lado de carga de la derecha para conocer la inserción correcta de los cables
correspondientes a las configuraciones de reactor (balasto).
5. Tome los cables de alimentación firmemente y empuje los conductores para introducirlos
en los orificios de conexión opuestos a los cables de carga. Vea el diagrama del lado de la
línea de la derecha para conocer la configuración correcta del cableado.
6. Use sólo un conductor por orificio y asegúrese de que no quede el cobre expuesto en
ninguno de los cables insertados.
7. Cuando reemplace los reactores, vea las instrucciones de desacoplamiento y acoplamiento
del dispositivo seccionador incluidas más abajo.
8. El lado de inserción de cables de este producto está especificado para USAR UNA SOLA
VEZ. NO RETIRE Y VUELVA A COLOCAR LOS CABLES.
PELIGRO
NUNCA retire los cables del producto, puesto que el contacto con la electricidad puede causar
graves lesiones o la muerte. Desconecte el suministro eléctrico en el disyuntor o quite el fusible
cuando vaya a instalar este producto.
AVISO SOBRE LA SEGURIDAD
El cableado eléctrico instalado incorrectamente puede ser peligroso y causar incendios eléctricos.
Este producto se debe usar de acuerdo con la especificación de corriente y los tamaños de cable
indicados. Consulte el código de construcción local antes de hacer un trabajo eléctrico.
COBRE A COBRE ÚNICAMENTE. No use el producto en aluminio. Temperatura nominal: 105°
(221°F) máximo CLASIFICACIÓN DE LLAMA UL94V-0.
Este dispositivo de desconexión está especificado para 600 V / 6 A máximo.
Clasificado para un número limitado de operaciones de interrupción de corriente
Rango de cables Lado de la línea (anaranjado) Lado del balasto
Macizo: 12-18 AWG 18 AWG
Trenzado: 12-14 AWG (19 hilos o menos)
Trenzado estañado: 14 AWG (19 hilos o menos) 18 AWG
16 AWG (26 hilos o menos) (16 hilos o menos)
18 AWG (16 hilos o menos)
Instrucciones de desacoplamiento y acoplamiento del dispositivo de desconexión
1. Para desacoplar, tome el dispositivo de desconexión por ambos extremos y tire para separar
las mitades del mismo.
2. Para acoplar el dispositivo de desconexión, tome ambas mitades del mismo, alinéelas y
presiónelas para unirlas.
IDEAL INDUSTRIES, INC.
1375 Park Avenue
Sycamore, IL 60178, U.S.A.
800-435-0705 Asistencia al cliente
www.idealind.com
ND
6847-7
Calietne
Línea de Carga
(3 puertos)
(Tapa naranja)
Neutral
Caliente #2
(Rojo)
BALASTO
BALASTO
BALASTO
BALASTO
Lado de Carga (6 puertos)
(White Cap)
Balasto único
(Red)
Atenuador
conmutable/por
pasos
Salida de máxima
luz
BALASTO

Transcripción de documentos

COPPER TO COPPER ONLY. Do not use on Aluminum. Temperature rating: 105°C (221°F) maximum. Flame Rated UL94V-0. This disconnect is rated for 600 Volts/6 Amps maximum. Rated for a limited number of current-interrupting operations. PowerPlug® Luminaire Disconnect Model 103 Installation Instructions: To be sold only with installation instructions. WARNING: This is a current rated device. Use in applications involving amperage beyond its rating can be dangerous and cause electrical fires. Do not exceed maximum current and voltage levels. Instructions: Conductor installation: 1. Wiring must comply with all applicable electrical codes. 2. Turn off power before removing or installing disconnect. 3. Strip wires to 3/8” (9,5 mm). 18 AWG can be 3/8” to 1/2” strip. 4. Grip load wires firmly and push conductors into white cap ports. See load side diagrams at right for proper wire insertion for ballast configurations. 5. Grip supply wires firmly and push conductors into ports opposite load wires. See line side diagram at right for proper wiring configuration. 6. Use only one conductor per port and assure that no copper is exposed on any of the wires inserted. 7. See disconnect de-mate/mate installation instructions below when replacing ballasts. 8. The wire insertion side of this product is listed for ONE TIME USE ONLY. DO NOT REMOVE AND REPLACE WIRES. DANGER NEVER remove wires from product as contact with electricity can cause serious injury or death. Shut off power at the circuit breaker or remove fuse when installing this product. SAFETY NOTICE Improperly installed electrical wiring can be dangerous and cause electrical fires. This product must be used in accordance with the current rating and wire sizes listed. Consult local building code before doing any electrical work. Wire Range Solid: Stranded: Stranded Tin Bonded: Line Side (Orange) Load Side (White) 12-18 AWG 12-14 AWG (19 Strand or less) 12-14 AWG (19 Strand or less) 16 AWG (26 Strand or less) 18 AWG (16 Strand or less) 18 AWG — 18 AWG (16 Strand or less) Disconnect de-mate / mate installation 1. To de-mate, grasp disconnect at each end and pull apart to separate the disconnect halves. Do NOT pull on wires. 2. To mate the disconnect, grasp each disconnect half, align halves, and push together. Line Side (3 Ports) Load Side (6 Ports) (Orange Cap) (White Cap) Hot Single Ballast (Red) Hot #2 (Red) BALLAST Neutral Switchable/Step Dimming BALLAST BALLAST IDEAL INDUSTRIES, INC. 1375 Park Avenue Sycamore, IL 60178, U.S.A. 800-435-0705 Customer Assistance www.idealind.com ND 6847-7 Full-Light Output BALLAST BALLAST COPPER TO COPPER ONLY. Do not use on Aluminum. Temperature rating: 105°C (221°F) maximum. Flame Rated UL94V-0. This disconnect is rated for 600 Volts/6 Amps maximum. Rated for a limited number of current-interrupting operations. PowerPlug® Luminaire Disconnect Model 103 Installation Instructions: To be sold only with installation instructions. WARNING: This is a current rated device. Use in applications involving amperage beyond its rating can be dangerous and cause electrical fires. Do not exceed maximum current and voltage levels. Instructions: Conductor installation: 1. Wiring must comply with all applicable electrical codes. 2. Turn off power before removing or installing disconnect. 3. Strip wires to 3/8” (9,5 mm). 18 AWG can be 3/8” to 1/2” strip. 4. Grip load wires firmly and push conductors into white cap ports. See load side diagrams at right for proper wire insertion for ballast configurations. 5. Grip supply wires firmly and push conductors into ports opposite load wires. See line side diagram at right for proper wiring configuration. 6. Use only one conductor per port and assure that no copper is exposed on any of the wires inserted. 7. See disconnect de-mate/mate installation instructions below when replacing ballasts. 8. The wire insertion side of this product is listed for ONE TIME USE ONLY. DO NOT REMOVE AND REPLACE WIRES. DANGER NEVER remove wires from product as contact with electricity can cause serious injury or death. Shut off power at the circuit breaker or remove fuse when installing this product. SAFETY NOTICE Improperly installed electrical wiring can be dangerous and cause electrical fires. This product must be used in accordance with the current rating and wire sizes listed. Consult local building code before doing any electrical work. Wire Range Solid: Stranded: Stranded Tin Bonded: Line Side (Orange) Load Side (White) 12-18 AWG 12-14 AWG (19 Strand or less) 12-14 AWG (19 Strand or less) 16 AWG (26 Strand or less) 18 AWG (16 Strand or less) 18 AWG — 18 AWG (16 Strand or less) Disconnect de-mate / mate installation 1. To de-mate, grasp disconnect at each end and pull apart to separate the disconnect halves. Do NOT pull on wires. 2. To mate the disconnect, grasp each disconnect half, align halves, and push together. Line Side (3 Ports) Load Side (6 Ports) (Orange Cap) (White Cap) Hot Hot #2 (Red) Single Ballast (Red) BALLAST Neutral Switchable/Step Dimming BALLAST BALLAST IDEAL INDUSTRIES, INC. 1375 Park Avenue Sycamore, IL 60178, U.S.A. 800-435-0705 Customer Assistance www.idealind.com ND 6847-7 Full-Light Output BALLAST BALLAST COBRE A COBRE ÚNICAMENTE. No use el producto en aluminio. Temperatura nominal: 105° (221°F) máximo CLASIFICACIÓN DE LLAMA UL94V-0. Este dispositivo de desconexión está especificado para 600 V / 6 A máximo. PowerPlug® Conector acoplador para accesorios luminosos - Model 103 Instrucciones Instalación: Para vender únicamente con instrucciones de instalación. Clasificado para un número limitado de operaciones de interrupción de corriente Rango de cables Macizo: Trenzado: Trenzado estañado: ADVERTENCIA: Éste es un dispositivo especificado por corriente. No exceda los niveles máximos de corriente y voltaje. Instrucciones – Instalación de los conductores : 1. El cableado debe cumplir todos los códigos eléctricos aplicables. 2. Desconecte la alimentación eléctrica antes de quitar o instalar el dispositivo seccionador. 3. Pele los cables 3/8” (9,5 mm). El cable 18 AWG se puede pelar de 9,5 a 13 mm (3/8 a 1/2”). 4. Tome los cables de carga firmemente y empuje los conductores para introducirlos en los orificios de conexión con tapas blancas. Vea los dia gramas del lado de carga de la derecha para conocer la inserción correcta de los cables correspondientes a las configuraciones de reactor (balasto). 5. Tome los cables de alimentación firmemente y empuje los conductores para introducirlos en los orificios de conexión opuestos a los cables de carga. Vea el diagrama del lado de la línea de la derecha para conocer la configuración correcta del cableado. 6. Use sólo un conductor por orificio y asegúrese de que no quede el cobre expuesto en ninguno de los cables insertados. 7. Cuando reemplace los reactores, vea las instrucciones de desacoplamiento y acoplamiento del dispositivo seccionador incluidas más abajo. 8. El lado de inserción de cables de este producto está especificado para USAR UNA SOLA VEZ. NO RETIRE Y VUELVA A COLOCAR LOS CABLES. PELIGRO NUNCA retire los cables del producto, puesto que el contacto con la electricidad puede causar graves lesiones o la muerte. Desconecte el suministro eléctrico en el disyuntor o quite el fusible cuando vaya a instalar este producto. AVISO SOBRE LA SEGURIDAD El cableado eléctrico instalado incorrectamente puede ser peligroso y causar incendios eléctricos. Este producto se debe usar de acuerdo con la especificación de corriente y los tamaños de cable indicados. Consulte el código de construcción local antes de hacer un trabajo eléctrico. Lado de la línea (anaranjado) 12-18 AWG 12-14 AWG (19 hilos o menos) 14 AWG (19 hilos o menos) 16 AWG (26 hilos o menos) 18 AWG (16 hilos o menos) Lado del balasto 18 AWG — 18 AWG (16 hilos o menos) Instrucciones de desacoplamiento y acoplamiento del dispositivo de desconexión 1. Para desacoplar, tome el dispositivo de desconexión por ambos extremos y tire para separar las mitades del mismo. 2. Para acoplar el dispositivo de desconexión, tome ambas mitades del mismo, alinéelas y presiónelas para unirlas. Línea de Carga Lado de Carga (6 puertos) (3 puertos) (White Cap) (Tapa naranja) (Red) Calietne Balasto único Caliente #2 (Rojo) BALASTO Atenuador conmutable/por pasos Neutral BALASTO BALASTO Salida de máxima luz IDEAL INDUSTRIES, INC. 1375 Park Avenue Sycamore, IL 60178, U.S.A. 800-435-0705 Asistencia al cliente www.idealind.com ND 6847-7 BALASTO BALASTO COBRE A COBRE ÚNICAMENTE. No use el producto en aluminio. Temperatura nominal: 105° (221°F) máximo CLASIFICACIÓN DE LLAMA UL94V-0. Este dispositivo de desconexión está especificado para 600 V / 6 A máximo. PowerPlug® Conector acoplador para accesorios luminosos - Model 103 Instrucciones Instalación: Para vender únicamente con instrucciones de instalación. Clasificado para un número limitado de operaciones de interrupción de corriente Rango de cables Macizo: Trenzado: Trenzado estañado: ADVERTENCIA: Éste es un dispositivo especificado por corriente. No exceda los niveles máximos de corriente y voltaje. Instrucciones – Instalación de los conductores : 1. El cableado debe cumplir todos los códigos eléctricos aplicables. 2. Desconecte la alimentación eléctrica antes de quitar o instalar el dispositivo seccionador. 3. Pele los cables 3/8” (9,5 mm). El cable 18 AWG se puede pelar de 9,5 a 13 mm (3/8 a 1/2”). 4. Tome los cables de carga firmemente y empuje los conductores para introducirlos en los orificios de conexión con tapas blancas. Vea los dia gramas del lado de carga de la derecha para conocer la inserción correcta de los cables correspondientes a las configuraciones de reactor (balasto). 5. Tome los cables de alimentación firmemente y empuje los conductores para introducirlos en los orificios de conexión opuestos a los cables de carga. Vea el diagrama del lado de la línea de la derecha para conocer la configuración correcta del cableado. 6. Use sólo un conductor por orificio y asegúrese de que no quede el cobre expuesto en ninguno de los cables insertados. 7. Cuando reemplace los reactores, vea las instrucciones de desacoplamiento y acoplamiento del dispositivo seccionador incluidas más abajo. 8. El lado de inserción de cables de este producto está especificado para USAR UNA SOLA VEZ. NO RETIRE Y VUELVA A COLOCAR LOS CABLES. PELIGRO NUNCA retire los cables del producto, puesto que el contacto con la electricidad puede causar graves lesiones o la muerte. Desconecte el suministro eléctrico en el disyuntor o quite el fusible cuando vaya a instalar este producto. AVISO SOBRE LA SEGURIDAD El cableado eléctrico instalado incorrectamente puede ser peligroso y causar incendios eléctricos. Este producto se debe usar de acuerdo con la especificación de corriente y los tamaños de cable indicados. Consulte el código de construcción local antes de hacer un trabajo eléctrico. Lado de la línea (anaranjado) 12-18 AWG 12-14 AWG (19 hilos o menos) 14 AWG (19 hilos o menos) 16 AWG (26 hilos o menos) 18 AWG (16 hilos o menos) Lado del balasto 18 AWG — 18 AWG (16 hilos o menos) Instrucciones de desacoplamiento y acoplamiento del dispositivo de desconexión 1. Para desacoplar, tome el dispositivo de desconexión por ambos extremos y tire para separar las mitades del mismo. 2. Para acoplar el dispositivo de desconexión, tome ambas mitades del mismo, alinéelas y presiónelas para unirlas. Línea de Carga Lado de Carga (6 puertos) (3 puertos) (White Cap) (Tapa naranja) Calietne Caliente #2 (Rojo) (Red) Balasto único BALASTO Neutral Atenuador conmutable/por pasos BALASTO BALASTO IDEAL INDUSTRIES, INC. 1375 Park Avenue Sycamore, IL 60178, U.S.A. 800-435-0705 Asistencia al cliente www.idealind.com ND 6847-7 Salida de máxima luz BALASTO BALASTO
  • Page 1 1
  • Page 2 2

Ideal 30-103X Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para

En otros idiomas