WARNING: For your safety read and understand instruc-
tions completely before starting installation. Before
wiring to power supply, turn off electricity at the fuse or
circuit breaker box. Halo recessed xtures are designed
to meet the latest NEC requirements and are UL listed in
full compliance with UL 1598. Before attempting installa-
tion of any recessed xture check your local electrical
code. This code sets the wiring standards for your locali-
ty and should be carefully studied before starting.
Housing Installation
Fixture is designed for installation where it may come
in contact with insulation (Fig. 1).
For 1/2” and 5/8” ceiling material
Step 1 Using template supplied, scribe a circle on ceiling in
desired location.
H573RICAT1D - 5 1/2"
H273RICAT1D - 6 1/4"
Step 2 Accurately cut hole in ceiling.
Step 3 Provide electrical service with exible cable only. Pass
cable through opening and wire xture in accordance
with NEC or your local electrical code.
Follow Steps 1
through 4 under “Electrical Connection.”
Step 4 With clips seated properly in can (Figure 2), insert
remodel housing into ceiling junction box rst.
Step 5 Hold xture up against ceiling and push clip through
housing slot (Figure 3).
Step 6 To lock clip in place, push at portion against side of
HALO
®
AVERTISSEMENT: Pour des raisons de sécurité, lire et
comprendre toutes les instructions avant l’installation.
Avant l’installation des ls, couper le courant au niveau
de la boîte des fusibles ou du disjoncteur.
Les appareils d’éclairage encastrés Halo sont conçus en
conformité avec les exigences du dernier «Code national
de l’électricité» et sont certiés par les UL conformément
aux normes UL 1598. Avant de commencer à installer
quelque luminaire encastré que ce soit, veuillez vérier
votre code régional de l’électricité. Ce code dénit les
normes en matière de câblage pour votre région. Lisez-le
attentivement avant l’installation de l’appareil.
Installation
L’appareil est spécialement conçu pour les endroits
il peut entrer en contact avec des isolants. (Voir Fig. 1)
1/2” et 5/8” plafond
Étape 1 Dessiner un cercle sur le plafond à l'endroit
voulu à l'aide du gabarit.
H573RICAT1D - 5 1/2"
H273RICAT1D - 6 1/4"
Étape 2 Percer un trou dans le plafond de façon précise.
Étape 3 Procurer de courant élecrique à l'aide d'un
cäble souple seulement. Passer le cäble à travers
l'ouverture et faire le câblage de l'appareil conformé-
ment au code national de l'électricité ou a votre code
d'électricité local. Suivre dans l’ordre les Étapes 1 à 4
de la section intitulée «Connexions électriques».
Paso 4 Con abrazaderas colocadas adecuadamente en
la caja metálica (gura 1), inserte primero el portalám-
paras para uso en renovaciones en la caja de
conexiones del techo.
Paso 5 Sujete el portalámparas contra el techo y empu-
je la abrazadera a través de la ranura de la caja
metálica (Figura 3).
Paso 6 Para cerrar la abrazadera adecuadamente,
empuje la parta plana contra el lado de la caja metáli-
ca (Figura 4)
ADVERTENCIA: Por su propia seguridad, lea cuida-
dosamente y entienda las instrucciones antes de iniciar
la instalación. Antes de conectar la lámpara a la fuente
eléctrica, desconecte dicha fuente desde la caja de
fusibles o bajando la palanca principal. Las luminarias
empotradas Halo satisfacen las más recientes normas
de instalación eléctrica y cuentan con la certicacion UL
al cumplir plenamente con UL 1598. Consulte las regula-
ciones eléctricas locales antes de instalar cualquier lumi-
naria empotrada. Estas regulaciones indican el tipo de
cableado autorizado en su localidad y deben ser estudi-
adas detenidamente antes de iniciar la instalación.
Instalación
Por su diseño, la lámpara instalada debe entrar en con-
tacto con materiales aislantes.
1/2” y 5/8” techo.
Paso 1 Usando la plantilla, trace un circulo en el techo
en el lugar deseado.
H573RICAT1D - 5 1/2"
H273RICAT1D - 6 1/4"
Paso 2 Corte el oricio en la pared con precisión
Paso 3 Proporcione la acometida de electricidad sólo
con el cable exible. Pase el cable por la abertura e
instale el portolámparas de acuerdo con el NEC
(Código Eléctrico Nacional) o su código elécrico local.
Siga los Pasos 1 a 4 descritos en "Connexión
Electrica".
Paso 4 Con abrazaderas colocadas adecuadamente en
la caja metálica (gura 2), inserte primero el portalám-
paras para uso en renovaciones en la caja de conex-
iones del techo.
Paso 5 Sujete el portalámparas contra el techo y empu-
je la abrazadera a través de la ranura de la caja
metálica (Figura 3).
Paso 6 Para cerrar la abrazadera adecuadamente,
empuje la parta plana contra el lado de la caja metáli-
ca (Figura 4)
Paso 7 Para sacarlo, tire hacia abajo de la abrazadera
(Figura 5).
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 704428 Rev. A
Risque de choc électrique
Couper le courant au fusible ou au dis-
joncteur avant l’installation ou toute
intervention
WARNING
Risk of Fire
Supply conductors (power wires)
connecting the fixture must be rated
minimum 90°C
If uncertain, consult an electrician
Risk of Electric Shock
Disconnect power at fuse or circuit
breaker before installing or servicing
Risk of Fire/Electric Shock
If not qualified, consult an electrician
Risque d’incendie
Les conducteurs d’alimentation (câbles
électriques) raccordant l’appareil
doivent supporter une température min-
imale de 90°C
En cas de doute, consulter un électricien
Riesgo de descarga eléctrica
Desconectar la electricidad en la caja
de fusibles o del disyuntor antes de
hacer la instalación o realizar tareas de
mantenimiento
Riesgo de incendio/ descarga eléctrica
Si usted no está habilitado, consulte
con un electricista
Riesgo de incendio
Los cables de alimentación (cables dis-
tribuidores de corriente) conectados a la
lámpara deben poder resistir temperat-
uras de 90°C como mínimo.
Si no está seguro, consulte con un electricista.
Risque d’incendie/de choc électrique
Consulter un spécialiste si non qualifié
ADVERTENCIA
AVERTISSEMENT
Recessed Downlight for Use
in Insulation
H273RICAT1D, H573RICAT1D
Éclairage direct encastré
pour isolantes
H273RICAT1D, H573RICAT1D
Luminaria Fija Empotrada para
uso en Material Aislante
H273RICAT1D, H573RICAT1D
FIG. 4
FIG. 5
FIG. 3
FIG. 2
FIG. 1
can (Figure 4).
Step 7 To complete installation, push up clip with screwdriver
until it snaps into place (gure 5).
Step 8 Install trim.
NOTE In areas where excessive ceiling vibration can occur, we
suggest you use a 1/4-14x1/2" pan HD sheet metal
screw to further lock the spring clips against the xture
housing. Drive the screw through the hole in the spring
clip and into the housing slot.
Installation for AIR-TITE™ Construction
AIR-TITE™ housings with ASTME283 certification are
supplied with an AIR-TITE™ gasket. When properly
installed, AIR-TITE™ housings provide compliance
with restricted air flow regulations: Washington State
Energy Code; California Title 24; New York Energy con-
servation Code; International Energy conservation
code (IECC)
Additional gaskets are available (GA-ATH5-6PK for 5”
and GA-ATH7-6PK for 6”) for sealing between fin-
ished ceiling and housing opening as needed.
Electrical Connection
Make certain no bare wires are exposed outside the
wire nut connectors.
For housings with push-nut connectors:
- Strip insulation 1/2”
- Use 12-16 AWG stranded (stranded pattern 19 or
less)
- or use 12-18 AWG solid copper wire
Step 1.
Provide electrical service according to the
“National Electrical Code" or your local electrical code
from a suitable junction box to the wiring box (locat-
ed on the plaster frame). Supply wire insulation must
be rated for at least 90˚C.
Step 2 Remove the wiring box cover.
Note: The wiring box will accept metal conduit or non-
metallic cable, but metal conduit must be used if your
electrical code requires it.
Flexible Metal conduit: Remove appropriate round
knock-out(s) and connect conduit to wiring box with prop-
er connector(s) (not included).
Non-metallic cable: Complete connections as out-
lined in step 3 and slide cable into wire traps (Fig. 7).
Step 3 Connect supply wires to wires in fixture wiring
box with proper size wire nuts (not included) or
push wires into “push-in” connectors. Be sure to
cover all bare current-carrying conductors.
Connect white to white; black to black; and green
or bare copper wire (from electrical service) to
bare copper wire (in wiring box).
Note: The ground
wire at the service junction box
may need to be secured to a ground screw.
Step 4 Place wires and connections back in wiring
box and replace cover.
Lamping Information
H273RICAT1D
G24q-3/GX24q-3 socket for one 26W DTT, 26W TTT* or
32W TTT* 4 pin compact uorescent lamp.
Generic Lamp Designations (lamp by others)
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
CFTR32W/GX24q 2700K / 82 CRI
CFTR32W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
*TTT = Triple Twin Tube (recommended for best per-
formance and visual comfort)
*DTT = Double Twin Tube or Quad Tube (not compatible
for selected lens trims due to longer length) see prod-
uct label for trim and lamp information
Paso 7 Para sacarlo, tire hacia abajo de la abrazadera
(Figura 5).
Paso 8 Instala el borde.
Nota: En zonas donde se produzca una vibración excesi-
va del techo, sugerimos que use tornillo de cabeza plan
de 1/4 - 14 x 1/2" para metal para cerrar más las
abrazaderas de muelle contra la caja del portolámparas.
Introduzca el tornillo por el orificio en la abrazadera de
muelle y en la ranura de la caja.
Installation de AIR-TITE™ dans une nouvelle
construction
Les boîtiers ALL-PRO® AIR-TITE™ homologués par la
norme ASTME283, sont fournis avec un joint préin-
stallé dans le cadre en plâtre :
Correctement installés, les boîtiers ALL-PRO AIR-
TITE™ sont en conformité avec les réglementations
en vigueur relatives au flux d’air restreint : Code de
l’Énergie de l’État de Washington ; Titre 24 de
Californie ; Code de la Construction et des Économies
d’Énergie de New York ; Code International relatif aux
Économies d’Énergie (IECC).
Une fois le plafond posé, d’autres joints vendus
séparément peuvent être ajoutés (GA-ATH5-6PK pour
5 po et GA ATH7-6PK pour 6 po) afin de maintenir l’é-
tanchéité entre le bas du plafond et l’ouverture du
boîtier.
Raccordements Électriques
Éviter, à tout prix, que des ls soient mis à nu à l’ex-
térieur des connecteurs d’écrous.
Pour les boîtiers à connecteurs à écrou capuchon :
- Retirez l’isolant sur1/2 po
- Utilisez un réseau sélectif planaire de 12-16 torsadé
(motif torsadé de 19 ou moins)
- ou utilisez un câble en cuivre solide pour réseau
sélectif planaire de 12-18
Étape 1 Effectuer les connexions conformément aux dis-
positions du Code national de l’électricité ou à
celles de votre code régional à partir d’une boîte
de jonction appropriée à la boîte de câblage
(sur le cadre en plâtre). L’isolant pour l d’ali-
mentation doit être
classé pour une température
minimale de 90° C.
Étape 2 Enlever le couvercle de la boîte de câblage.
Remarque: L’on peut utiliser un conduit métallique ou
un câble non métallique dans la boîte de câblage, mais l’u-
tilisation d’un conduit métallique est requise si votre code de
l’électricité l’exige.
Conduit métallique: Enlever les débouchures rondes
appropriées et connecter le conduit à la boîte de câblage à
l’aide des connecteurs appropriés (non compris).
Câble non métallique: Effectuer les connexions
indiquées à l’étape 3 et insérer le câble dans les con-
necteurs (voir g. 4).
Étape 3 Connecter les ls de l’alimentation à ceux de la
boîte de jonction de l’appareil d’éclairage au moyen de
connecteurs de ls de la taille appropriée (non compris)
ou insérer les ls dans les connecteurs « à poussée » .
S’assurer de couvrir tous les conducteurs nus sous ten-
sion. Raccorder le l blanc au l blanc, le l noir au l
noir et le l vert ou le l nu en cuivre (du réseau d’élec-
tricité) au l nu en cuivre (de la boîte de jonction de l’ap-
pareil d’éclairage).
Remarque: Il se peut que le l de mise à la terre de la boîte
de jonction doive être xé à une vis de mise à la terre.
Étape 4 Insérer tous les ls et toutes les connexions dans
la boîte de câblage. Remettre le couvercle.
Paso 8 Instala el borde.
Nota: En zonas donde se produzca una vibración exce-
siva del techo, sugerimos que use tornillo de cabeza
plan de 1/4 - 14 x 1/2" para metal para cerrar más las
abrazaderas de muelle contra la caja del portolámparas.
Introduzca el tornillo por el orificio en la abrazadera de
muelle y en la ranura de la caja.
Instalación para AIR-TITE™ en
construcciones nuevas
Todos los alojamientos ALL-PRO, certificados bajo
ASTM E283, se suministran con una empaquetadura ya
instalada en el marco de yeso:
Cuando están correctamente instala-dos, los alo-
jamientos ALL-PRO AIR-TITE™ cumplen con las
regu-laciones referentes al flujo de aire restringido.
Código de Energía del Estado de Washington;
California Titulo 24; Código de Construcción -
Conservación de Energía - de Nueva York; Código
Internacional de Conservación de Energía (IECC)
Después de instalar el techo, se cuenta con empa-
quetaduras adicionales (GA-ATH5-6PK para 5 pul-
gadas y GA-ATH7-6PK para 6 pulgadas) para
realizar un sellado, como se requiera, entre la parte
inferior del cielo raso y la abertura del alojamiento.
Conexión Eléctrica
No deje ningún cable suelto o desnudo alrededor de
los cables conectados.
Para cubiertas con conectores a presión:
Quitar 1/2" del aislamiento
Utilizar cable trenzado calibre 12-16, según la
Escala americana para calibres de alambre AWG
(patrón de trenzado de 19 o menos)
- O utilizar un alambre de cobre macizo calibre 12-
18 AWG
Paso 1 Asegure que los cables del cielo raso donde
instalará la lámpara estén conectados a una caja de
distribución eléctrica en conformidad con las normas
locales para instalaciones eléctricas. El cable de ali-
mentación en el cielo raso debe poder resistir temper-
aturas de 90° C como mínimo.
Paso 2 Retire la tapa de la caja de conexiones del
portalámpara.
Nota: La caja de conexiones del portalámpara acep-
tará cables conductores metálicos o no metálicos, pero
si las normas de electricidad locales lo exigen, debe
usar cable conductor metálico.
Cable conductor metálico: Desprenda mediante pre-
sión las placas circulares necesarias y conecte el cable
del cielo raso a las conexiones del portalámpara. Utilice
conos plásticos de conexión eléctrica para unir los
cables (no incluidos en el modelo).
Cable no metálico: complete las conexiones tal como
se indica en el paso 3 e inserte el cable en la trampa
(Fig. 4).
Paso 3 Conecte los cables de alimentación a los
cables de la caja de conexiones del portalámpara
usando conos plásticos de conexión eléctrica de
tamaño apropiado (no incluidos) o inserte los cables
dentro de los conectores “a presión”. Asegúrese de
cubrir todos los cables desnudos conductores de
corriente. Conecte el blanco con el blanco, el negro
con el negro y el verde o el cable desnudo de cobre
(del servicio eléctrico) al cable desnudo de cobre
(de la caja de conexiones).
Nota: Probablemente deba atornillar el cable de tierra
de la caja de distribución eléctrica a un tornillo de tier-
ra.
Paso 4 Reacomode todos los cables en la caja de
conexiones del portalámpara y vuelva a colocar la tapa
de la misma.
HALO
®
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 704428 Rev. A
H573RICAT1D
G24q-3/GX24q-3 socket for one 26W DTT, 26W
TTT*
4-pin compact uorescent lamp.
Generic Lamp Designations (lamp by others)
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
*TTT = Triple Twin Tube (recommended for best
performance and visual comfort)
*DTT = Double Twin Tube or Quad Tube (not
compatible for selected lens trims due to longer
length) see product label for trim and lamp
information
Recommended Switch
The H273RICAT1D and H573RICAT1D are rated
for use with uorescent dimmers rated for the
Advance dimming ballast labeled "Mark 10" (or
"Mark X").
For compatible Lutron uorescent wall dimmers
go www.lutron.com/advance and refer to the list-
ing for "Mark X" dimmers
For compatible Leviton uorescent wall dimmers
go to http://www.leviton.com >Lighting Controls
>Residential >Dimmers and browse for "Mark
10" (or "Mark X"). dimmers, or Call Leviton Tech
Line at 1-800-824-3005 and ask for "Mark 10"
wall dimmers
For a list of other manufacturers of "Mark 10" (or
"Mark X") rated uorescent dimmers go to the
Advance""Mark 10" (or "Mark X") " website
at http://www.advancetransformer.com/prod-
ucts/uorescent-electronic.jsp?pbid=37
Ballast Replacement
NOTE: Ballast should be replaced by a qualied
electrician
Step 1. Remove trim.
To release housing, pull down
on clip (Figure 3).
Step 3.Disconnect ballast from input wiring and
lampholder leads (leads are terminated
with either wire nuts or push release con-
nectors on ballast).
Step 4.Remove outer junction box cover with
ballast attached by releasing spring clip.
Step 5. Replace ballast with a Factory Approved,
Energy Star and Title 24 qualied ballast.
Step 6. Reinstall ballast by reversing steps 1
through 4
Renseignements sur les ampoules
H273RICAT1D
Prise de G24q-1/GX24-1 pour une lampe uorescente
compacte à 4 ergots avec un DTT* ou un TTT.
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
CFTR32W/GX24q 2700K / 82 CRI
CFTR32W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT-Triple à double tubes (pour de meilleures perform-
ances et davantage de confort visuel)
DTT-Double à double tubes (sa longueur plus importante
ne la rend pas compatible avec toutes les installations –
lire les informations fournies sur l’étiquette)
H573RICAT1D
Prise de G24q-1/GX24-1 pour une lampe uorescente
compacte à 4 ergots avec un DTT* ou un TTT.
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT-Triple à double tubes (pour de meilleures perform-
ances et davantage de confort visuel)
DTT-Double à double tubes (sa longueur plus importante
ne la rend pas compatible avec toutes les installations –
lire les informations fournies sur l’étiquette)
Interrupteur à variateur
(H273ICAT1D and H573ICAT1D) Compatible avec les
"Mark 10" (ou "Mark X") interrupteur à variateur.
Lutron uorescentes interrupteur à variateur:
www.lutron.com/advance "Mark X"
Leviton uorescentes interrupteur à variateur:
http://www.leviton.com >Lighting Controls >Residential
>Dimmers and browse for "Mark 10" (or "Mark X"). dim-
mers, ou Leviton Tech Line 1-800-824-3005
Advance "Mark 10" (ou "Mark X") http://www.advance-
transformer.com/products/uorescent-
electronic.jsp?pbid=37
Remplacement du ballast
NOTA: Le ballast doit être remplacé par un électricien
qualié
Étape 1. Enlevez la garniture et abaissez le caisson
du cadre à sceller en dévissant les trois vis (Fig. 6).
Étape 2. Retirez le couvercle intérieur de la boite à
bornes en relâchant le ressort.
Étape 3. Débranchez le ballast du câblage d’entrée et
des ls de sortie de la douille (les ls de sortie sont
raccordés au ballast avec des serre-ls ou des con-
necteurs de poussée-déclenchement).
Étape 4. Retirez le couvercle extérieur de la boite à
bornes avec le ballast accroché en relâchant le
ressort.
Étape 5. Remplacez le ballast avec un ballast de pièce
d’origine qui est homologué par l’étoile Energy Star®.
Étape 6. Réinstallez le ballast en inversant les étapes 1
jusqu’à 4.
Información sobre los bombillos
H273RICAT1D
Portalámparas G24q-1/GX24-1 para una lámpara uorescente
compacta de 4 pines 13W DTT* o 13W TTT. Lámparas genéric-
as de 13W de otras marcas (por otros)
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
CFTR32W/GX24q 2700K / 82 CRI
CFTR32W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT-Triple Tubo doble (recomendado para el mejor rendimien-
to y comodidad visual
DTT-Doble Tubo doble (no compatible con todos los adita-
mentos debido a un mayor largo, consulte la etiqueta del pro-
ducto para ver la información de la lámpara y los aditamentos
H573RICAT
Portalámparas G24q-1/GX24-1 para una lámpara uorescente
compacta de 4 pines 13W DTT* o 13W TTT. Lámparas genéric-
as de 13W de otras marcas (por otros)
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT-Triple Tubo doble (recomendado para el mejor rendimien-
to y comodidad visual
DTT-Doble Tubo doble (no compatible con todos los adita-
mentos debido a un mayor largo, consulte la etiqueta del pro-
ducto para ver la información de la lámpara y los aditamentos
Interruptor
(H273ICAT1D y H573ICAT1D) para uso Advance "Mark 10"
(or "Mark X") interruptor.
Lutron interruptor:
www.lutron.com/advance “Mark 10” o “Mark X”
Leviton interruptor:
http://www.leviton.com >Lighting Controls >Residential
>Dimmers "Mark 10" (o "Mark X").
Leviton Tech Line:1-800-824-3005
Advance "Mark 10" (o "Mark X"):
"Mark 10" (o "Mark X") "
http://www.advancetransformer.com/products/uorescent-
electronic.jsp?pbid=37
Reemplazo de balasto
NOTA: El balasto debe ser reemplazado por un electricista
calicado.
Paso 1. Retire la lámpara y la carcasa extraíble de la estruc-
tura de yeso, retirando tres tornillos (Fig. 6).
Paso 2. Retire la cubierta de la caja de empalmes interior qui-
tando el resorte.
Paso 3. Desconecte el balasto del alambrado de entrada y
los cables conductores del portalámpara (los cables con-
ductores terminan ya sea en tuercas de alambre o conec-
tores de liberación a presión sobre el balasto).
Paso 4. Retire la cubierta de la caja de empalmes exterior
con el balasto adjunto quitando el resorte.
Paso 5. Reemplace el balasto por uno aprobado de fábrica y
calicado por Energy Star.
Paso 6. uelva a instalar el balasto invirtiendo los pasos del 1
al 4.
HALO
®
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 704428 Rev. A

Transcripción de documentos

HALO® Recessed Downlight for Use Éclairage direct encastré in Insulation pour isolantes Luminaria Fija Empotrada para uso en Material Aislante H273RICAT1D, H573RICAT1D H273RICAT1D, H573RICAT1D H273RICAT1D, H573RICAT1D WARNING Risk of Fire Supply conductors (power wires) connecting the fixture must be rated minimum 90°C If uncertain, consult an electrician Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing Risk of Fire/Electric Shock If not qualified, consult an electrician WARNING: For your safety read and understand instructions completely before starting installation. Before wiring to power supply, turn off electricity at the fuse or circuit breaker box. Halo recessed fixtures are designed to meet the latest NEC requirements and are UL listed in full compliance with UL 1598. Before attempting installation of any recessed fixture check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting. Housing Installation • Fixture is designed for installation where it may come in contact with insulation (Fig. 1). • For 1/2” and 5/8” ceiling material Step 1 Using template supplied, scribe a circle on ceiling in desired location. H573RICAT1D - 5 1/2" H273RICAT1D - 6 1/4" Step 2 Accurately cut hole in ceiling. AVERTISSEMENT ADVERTENCIA Risque d’incendie Les conducteurs d’alimentation (câbles électriques) raccordant l’appareil doivent supporter une température minimale de 90°C Riesgo de incendio Los cables de alimentación (cables distribuidores de corriente) conectados a la lámpara deben poder resistir temperaturas de 90°C como mínimo. Si no está seguro, consulte con un electricista. Risque de choc électrique Couper le courant au fusible ou au disjoncteur avant l’installation ou toute intervention Riesgo de descarga eléctrica Desconectar la electricidad en la caja de fusibles o del disyuntor antes de hacer la instalación o realizar tareas de mantenimiento En cas de doute, consulter un électricien Risque d’incendie/de choc électrique Consulter un spécialiste si non qualifié AVERTISSEMENT: Pour des raisons de sécurité, lire et comprendre toutes les instructions avant l’installation. Avant l’installation des fils, couper le courant au niveau de la boîte des fusibles ou du disjoncteur. Riesgo de incendio/ descarga eléctrica Si usted no está habilitado, consulte con un electricista ADVERTENCIA: Por su propia seguridad, lea cuidadosamente y entienda las instrucciones antes de iniciar la instalación. Antes de conectar la lámpara a la fuente Les appareils d’éclairage encastrés Halo sont conçus en eléctrica, desconecte dicha fuente desde la caja de conformité avec les exigences du dernier «Code national fusibles o bajando la palanca principal. Las luminarias de l’électricité» et sont certifiés par les UL conformément empotradas Halo satisfacen las más recientes normas de instalación eléctrica y cuentan con la certificacion UL aux normes UL 1598. Avant de commencer à installer al cumplir plenamente con UL 1598. Consulte las regulaquelque luminaire encastré que ce soit, veuillez vérifier ciones eléctricas locales antes de instalar cualquier lumivotre code régional de l’électricité. Ce code définit les normes en matière de câblage pour votre région. Lisez-le naria empotrada. Estas regulaciones indican el tipo de cableado autorizado en su localidad y deben ser estudiattentivement avant l’installation de l’appareil. adas detenidamente antes de iniciar la instalación. Installation Instalación • L’appareil est spécialement conçu pour les endroits où • Por su diseño, la lámpara instalada debe entrar en conil peut entrer en contact avec des isolants. (Voir Fig. 1) tacto con materiales aislantes. • 1/2” et 5/8” plafond Étape 1 Dessiner un cercle sur le plafond à l'endroit voulu à l'aide du gabarit. H573RICAT1D - 5 1/2" H273RICAT1D - 6 1/4" • 1/2” y 5/8” techo. Paso 1 Usando la plantilla, trace un circulo en el techo en el lugar deseado. Step 3 Provide electrical service with flexible cable only. Pass H573RICAT1D - 5 1/2" cable through opening and wire fixture in accordance H273RICAT1D - 6 1/4" with NEC or your local electrical code. Follow Steps 1 Paso 2 Corte el orificio en la pared con precisión Étape 2 Percer un trou dans le plafond de façon précise. through 4 under “Electrical Connection.” Paso 3 Proporcione la acometida de electricidad sólo Étape 3 Procurer de courant élecrique à l'aide d'un Step 4 With clips seated properly in can (Figure 2), insert con el cable flexible. Pase el cable por la abertura e cäble souple seulement. Passer le cäble à travers remodel housing into ceiling junction box first. instale el portolámparas de acuerdo con el NEC l'ouverture et faire le câblage de l'appareil conformé(Código Eléctrico Nacional) o su código elécrico local. Step 5 Hold fixture up against ceiling and push clip through ment au code national de l'électricité ou a votre code Siga los Pasos 1 a 4 descritos en "Connexión housing slot (Figure 3). d'électricité local. Suivre dans l’ordre les Étapes 1 à 4 Electrica". de la section intitulée «Connexions électriques». Step 6 To lock clip in place, push flat portion against side of Paso 4 Con abrazaderas colocadas adecuadamente en Paso 4 Con abrazaderas colocadas adecuadamente en la caja metálica (figura 2), inserte primero el portalámla caja metálica (figura 1), inserte primero el portalámFIG. 1 paras para uso en renovaciones en la caja de conexparas para uso en renovaciones en la caja de iones del techo. conexiones del techo. Paso 5 Sujete el portalámparas contra el techo y empuje la abrazadera a través de la ranura de la caja metálica (Figura 3). Paso 5 Sujete el portalámparas contra el techo y empuje la abrazadera a través de la ranura de la caja metálica (Figura 3). Paso 6 Para cerrar la abrazadera adecuadamente, empuje la parta plana contra el lado de la caja metálica (Figura 4) Paso 6 Para cerrar la abrazadera adecuadamente, empuje la parta plana contra el lado de la caja metálica (Figura 4) Paso 7 Para sacarlo, tire hacia abajo de la abrazadera (Figura 5). FIG. 2 FIG. 3 FIG. 4 FIG. 5 Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 704428 Rev. A HALO® can (Figure 4). Step 7 To complete installation, push up clip with screwdriver until it snaps into place (figure 5). Step 8 Install trim. NOTE In areas where excessive ceiling vibration can occur, we suggest you use a 1/4-14x1/2" pan HD sheet metal screw to further lock the spring clips against the fixture housing. Drive the screw through the hole in the spring clip and into the housing slot. Installation for AIR-TITE™ Construction AIR-TITE™ housings with ASTME283 certification are supplied with an AIR-TITE™ gasket. When properly installed, AIR-TITE™ housings provide compliance with restricted air flow regulations: Washington State Energy Code; California Title 24; New York Energy conservation Code; International Energy conservation code (IECC) Additional gaskets are available (GA-ATH5-6PK for 5” and GA-ATH7-6PK for 6”) for sealing between finished ceiling and housing opening as needed. Electrical Connection • Make certain no bare wires are exposed outside the wire nut connectors. • For housings with push-nut connectors: - Strip insulation 1/2” - Use 12-16 AWG stranded (stranded pattern 19 or less) - or use 12-18 AWG solid copper wire Step 1. Provide electrical service according to the “National Electrical Code" or your local electrical code from a suitable junction box to the wiring box (located on the plaster frame). Supply wire insulation must be rated for at least 90˚C. Step 2 Remove the wiring box cover. Note: The wiring box will accept metal conduit or nonmetallic cable, but metal conduit must be used if your electrical code requires it. Flexible Metal conduit: Remove appropriate round knock-out(s) and connect conduit to wiring box with proper connector(s) (not included). Non-metallic cable: Complete connections as outlined in step 3 and slide cable into wire traps (Fig. 7). Step 3 Connect supply wires to wires in fixture wiring box with proper size wire nuts (not included) or push wires into “push-in” connectors. Be sure to cover all bare current-carrying conductors. Connect white to white; black to black; and green or bare copper wire (from electrical service) to bare copper wire (in wiring box). Note: The ground wire at the service junction box may need to be secured to a ground screw. Step 4 Place wires and connections back in wiring box and replace cover. Lamping Information H273RICAT1D G24q-3/GX24q-3 socket for one 26W DTT, 26W TTT* or 32W TTT* 4 pin compact fluorescent lamp. Generic Lamp Designations (lamp by others) TTT: CFTR26W/GX24q CFTR26W/GX24q CFTR32W/GX24q CFTR32W/GX24q DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI 2700K 3000K 2700K 3000K / / / / 82 82 82 82 CRI CRI CRI CRI *TTT = Triple Twin Tube (recommended for best performance and visual comfort) Paso 7 Para sacarlo, tire hacia abajo de la abrazadera (Figura 5). Paso 8 Instala el borde. Nota: En zonas donde se produzca una vibración excesiva del techo, sugerimos que use tornillo de cabeza plan de 1/4 - 14 x 1/2" para metal para cerrar más las abrazaderas de muelle contra la caja del portolámparas. Introduzca el tornillo por el orificio en la abrazadera de muelle y en la ranura de la caja. Installation de AIR-TITE™ dans une nouvelle construction Les boîtiers ALL-PRO® AIR-TITE™ homologués par la norme ASTME283, sont fournis avec un joint préinstallé dans le cadre en plâtre : Correctement installés, les boîtiers ALL-PRO AIRTITE™ sont en conformité avec les réglementations en vigueur relatives au flux d’air restreint : Code de l’Énergie de l’État de Washington ; Titre 24 de Californie ; Code de la Construction et des Économies d’Énergie de New York ; Code International relatif aux Économies d’Énergie (IECC). Une fois le plafond posé, d’autres joints vendus séparément peuvent être ajoutés (GA-ATH5-6PK pour 5 po et GA ATH7-6PK pour 6 po) afin de maintenir l’étanchéité entre le bas du plafond et l’ouverture du boîtier. Raccordements Électriques • Éviter, à tout prix, que des fils soient mis à nu à l’extérieur des connecteurs d’écrous. Pour les boîtiers à connecteurs à écrou capuchon : - Retirez l’isolant sur1/2 po - Utilisez un réseau sélectif planaire de 12-16 torsadé (motif torsadé de 19 ou moins) - ou utilisez un câble en cuivre solide pour réseau sélectif planaire de 12-18 Étape 1 Effectuer les connexions conformément aux dispositions du Code national de l’électricité ou à celles de votre code régional à partir d’une boîte de jonction appropriée à la boîte de câblage (sur le cadre en plâtre). L’isolant pour fil d’alimentation doit être classé pour une température minimale de 90° C. Étape 2 Enlever le couvercle de la boîte de câblage. Remarque: L’on peut utiliser un conduit métallique ou un câble non métallique dans la boîte de câblage, mais l’utilisation d’un conduit métallique est requise si votre code de l’électricité l’exige. Conduit métallique: Enlever les débouchures rondes appropriées et connecter le conduit à la boîte de câblage à l’aide des connecteurs appropriés (non compris). Câble non métallique: Effectuer les connexions indiquées à l’étape 3 et insérer le câble dans les connecteurs (voir fig. 4). Étape 3 Connecter les fils de l’alimentation à ceux de la boîte de jonction de l’appareil d’éclairage au moyen de connecteurs de fils de la taille appropriée (non compris) ou insérer les fils dans les connecteurs « à poussée » . S’assurer de couvrir tous les conducteurs nus sous tension. Raccorder le fil blanc au fil blanc, le fil noir au fil noir et le fil vert ou le fil nu en cuivre (du réseau d’électricité) au fil nu en cuivre (de la boîte de jonction de l’appareil d’éclairage). Remarque: Il se peut que le fil de mise à la terre de la boîte de jonction doive être fixé à une vis de mise à la terre. Étape 4 Insérer tous les fils et toutes les connexions dans la boîte de câblage. Remettre le couvercle. Paso 8 Instala el borde. Nota: En zonas donde se produzca una vibración excesiva del techo, sugerimos que use tornillo de cabeza plan de 1/4 - 14 x 1/2" para metal para cerrar más las abrazaderas de muelle contra la caja del portolámparas. Introduzca el tornillo por el orificio en la abrazadera de muelle y en la ranura de la caja. Instalación para AIR-TITE™ en construcciones nuevas Todos los alojamientos ALL-PRO, certificados bajo ASTM E283, se suministran con una empaquetadura ya instalada en el marco de yeso: Cuando están correctamente instala-dos, los alojamientos ALL-PRO AIR-TITE™ cumplen con las regu-laciones referentes al flujo de aire restringido. Código de Energía del Estado de Washington; California Titulo 24; Código de Construcción Conservación de Energía - de Nueva York; Código Internacional de Conservación de Energía (IECC) Después de instalar el techo, se cuenta con empaquetaduras adicionales (GA-ATH5-6PK para 5 pulgadas y GA-ATH7-6PK para 6 pulgadas) para realizar un sellado, como se requiera, entre la parte inferior del cielo raso y la abertura del alojamiento. Conexión Eléctrica • No deje ningún cable suelto o desnudo alrededor de los cables conectados. • Para cubiertas con conectores a presión: Quitar 1/2" del aislamiento Utilizar cable trenzado calibre 12-16, según la Escala americana para calibres de alambre AWG (patrón de trenzado de 19 o menos) - O utilizar un alambre de cobre macizo calibre 1218 AWG Paso 1 Asegure que los cables del cielo raso donde instalará la lámpara estén conectados a una caja de distribución eléctrica en conformidad con las normas locales para instalaciones eléctricas. El cable de alimentación en el cielo raso debe poder resistir temperaturas de 90° C como mínimo. Paso 2 Retire la tapa de la caja de conexiones del portalámpara. Nota: La caja de conexiones del portalámpara aceptará cables conductores metálicos o no metálicos, pero si las normas de electricidad locales lo exigen, debe usar cable conductor metálico. Cable conductor metálico: Desprenda mediante presión las placas circulares necesarias y conecte el cable del cielo raso a las conexiones del portalámpara. Utilice conos plásticos de conexión eléctrica para unir los cables (no incluidos en el modelo). Cable no metálico: complete las conexiones tal como se indica en el paso 3 e inserte el cable en la trampa (Fig. 4). Paso 3 Conecte los cables de alimentación a los cables de la caja de conexiones del portalámpara usando conos plásticos de conexión eléctrica de tamaño apropiado (no incluidos) o inserte los cables dentro de los conectores “a presión”. Asegúrese de cubrir todos los cables desnudos conductores de corriente. Conecte el blanco con el blanco, el negro con el negro y el verde o el cable desnudo de cobre (del servicio eléctrico) al cable desnudo de cobre (de la caja de conexiones). Nota: Probablemente deba atornillar el cable de tierra de la caja de distribución eléctrica a un tornillo de tierra. Paso 4 Reacomode todos los cables en la caja de conexiones del portalámpara y vuelva a colocar la tapa de la misma. *DTT = Double Twin Tube or Quad Tube (not compatible for selected lens trims due to longer length) see product label for trim and lamp information Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 704428 Rev. A HALO® G24q-3/GX24q-3 socket for one 26W DTT, 26W TTT* 4-pin compact fluorescent lamp. Generic Lamp Designations (lamp by others) TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI *TTT = Triple Twin Tube (recommended for best performance and visual comfort) *DTT = Double Twin Tube or Quad Tube (not compatible for selected lens trims due to longer length) see product label for trim and lamp information Recommended Switch The H273RICAT1D and H573RICAT1D are rated for use with fluorescent dimmers rated for the Advance dimming ballast labeled "Mark 10" (or "Mark X"). For compatible Lutron fluorescent wall dimmers go www.lutron.com/advance and refer to the listing for "Mark X" dimmers For compatible Leviton fluorescent wall dimmers go to http://www.leviton.com >Lighting Controls >Residential >Dimmers and browse for "Mark 10" (or "Mark X"). dimmers, or Call Leviton Tech Line at 1-800-824-3005 and ask for "Mark 10" wall dimmers For a list of other manufacturers of "Mark 10" (or "Mark X") rated fluorescent dimmers go to the Advance " "Mark 10" (or "Mark X") " website at http://www.advancetransformer.com/products/fluorescent-electronic.jsp?pbid=37 Ballast Replacement NOTE: Ballast should be replaced by a qualified electrician Step 1. Remove trim. To release housing, pull down on clip (Figure 3). Step 3.Disconnect ballast from input wiring and lampholder leads (leads are terminated with either wire nuts or push release connectors on ballast). Step 4.Remove outer junction box cover with ballast attached by releasing spring clip. Step 5. Replace ballast with a Factory Approved, Energy Star and Title 24 qualified ballast. Step 6. Reinstall ballast by reversing steps 1 through 4 Información sobre los bombillos Renseignements sur les ampoules H573RICAT1D H273RICAT1D H273RICAT1D Prise de G24q-1/GX24-1 pour une lampe fluorescente compacte à 4 ergots avec un DTT* ou un TTT. Portalámparas G24q-1/GX24-1 para una lámpara fluorescente compacta de 4 pines 13W DTT* o 13W TTT. Lámparas genéricas de 13W de otras marcas (por otros) TTT: CFTR26W/GX24q CFTR26W/GX24q CFTR32W/GX24q CFTR32W/GX24q TTT: CFTR26W/GX24q CFTR26W/GX24q CFTR32W/GX24q CFTR32W/GX24q DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI 2700K 3000K 2700K 3000K / / / / 82 82 82 82 CRI CRI CRI CRI TTT-Triple à double tubes (pour de meilleures performances et davantage de confort visuel) DTT-Double à double tubes (sa longueur plus importante ne la rend pas compatible avec toutes les installations – lire les informations fournies sur l’étiquette) TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI TTT-Triple à double tubes (pour de meilleures performances et davantage de confort visuel) DTT-Double à double tubes (sa longueur plus importante ne la rend pas compatible avec toutes les installations – lire les informations fournies sur l’étiquette) Interrupteur à variateur (H273ICAT1D and H573ICAT1D) Compatible avec les "Mark 10" (ou "Mark X") interrupteur à variateur. Lutron fluorescentes interrupteur à variateur: www.lutron.com/advance "Mark X" Leviton fluorescentes interrupteur à variateur: http://www.leviton.com >Lighting Controls >Residential >Dimmers and browse for "Mark 10" (or "Mark X"). dimmers, ou Leviton Tech Line 1-800-824-3005 Advance "Mark 10" (ou "Mark X") http://www.advancetransformer.com/products/fluorescentelectronic.jsp?pbid=37 Remplacement du ballast NOTA: Le ballast doit être remplacé par un électricien qualifié Étape 1. Enlevez la garniture et abaissez le caisson du cadre à sceller en dévissant les trois vis (Fig. 6). / / / / 82 82 82 82 CRI CRI CRI CRI TTT-Triple Tubo doble (recomendado para el mejor rendimiento y comodidad visual DTT-Doble Tubo doble (no compatible con todos los aditamentos debido a un mayor largo, consulte la etiqueta del producto para ver la información de la lámpara y los aditamentos H573RICAT1D Prise de G24q-1/GX24-1 pour une lampe fluorescente compacte à 4 ergots avec un DTT* ou un TTT. 2700K 3000K 2700K 3000K H573RICAT Portalámparas G24q-1/GX24-1 para una lámpara fluorescente compacta de 4 pines 13W DTT* o 13W TTT. Lámparas genéricas de 13W de otras marcas (por otros) TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI TTT-Triple Tubo doble (recomendado para el mejor rendimiento y comodidad visual DTT-Doble Tubo doble (no compatible con todos los aditamentos debido a un mayor largo, consulte la etiqueta del producto para ver la información de la lámpara y los aditamentos Interruptor (H273ICAT1D y H573ICAT1D) para uso Advance "Mark 10" (or "Mark X") interruptor. Lutron interruptor: www.lutron.com/advance “Mark 10” o “Mark X” Leviton interruptor: http://www.leviton.com >Lighting Controls >Residential >Dimmers "Mark 10" (o "Mark X"). Leviton Tech Line:1-800-824-3005 Advance "Mark 10" (o "Mark X"): "Mark 10" (o "Mark X") " http://www.advancetransformer.com/products/fluorescentelectronic.jsp?pbid=37 Reemplazo de balasto NOTA: El balasto debe ser reemplazado por un electricista calificado. Étape 2. Retirez le couvercle intérieur de la boite à bornes en relâchant le ressort. Paso 1. Retire la lámpara y la carcasa extraíble de la estructura de yeso, retirando tres tornillos (Fig. 6). Étape 3. Débranchez le ballast du câblage d’entrée et des fils de sortie de la douille (les fils de sortie sont raccordés au ballast avec des serre-fils ou des connecteurs de poussée-déclenchement). Paso 2. Retire la cubierta de la caja de empalmes interior quitando el resorte. Étape 4. Retirez le couvercle extérieur de la boite à bornes avec le ballast accroché en relâchant le ressort. Étape 5. Remplacez le ballast avec un ballast de pièce d’origine qui est homologué par l’étoile Energy Star®. Étape 6. Réinstallez le ballast en inversant les étapes 1 jusqu’à 4. Paso 3. Desconecte el balasto del alambrado de entrada y los cables conductores del portalámpara (los cables conductores terminan ya sea en tuercas de alambre o conectores de liberación a presión sobre el balasto). Paso 4. Retire la cubierta de la caja de empalmes exterior con el balasto adjunto quitando el resorte. Paso 5. Reemplace el balasto por uno aprobado de fábrica y calificado por Energy Star. Paso 6. uelva a instalar el balasto invirtiendo los pasos del 1 al 4. Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 704428 Rev. A
  • Page 1 1
  • Page 2 2
  • Page 3 3

Halo H273RICAT1D Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para