Halo H272RICAT Instrucciones de operación

Tipo
Instrucciones de operación

Este manual también es adecuado para

WARNING: For your safety read and understand instruc-
tions completely before starting installation. Before
wiring to power supply, turn off electricity at the fuse or
circuit breaker box. Halo recessed res are designed
to meet the latest NEC requirements and are UL listed in
full compliance with UL 1598. Before attempting installa-
tion of any recessed
re check your local electrical
code. This code sets the wiring standards for your locali-
ty and should be carefully studied before starting.
Housing Installation
Note: If
re is to be switched from wall switch, make
sure black power supply wire is connected to the switch.
DO NOT connect the white supply wire to the switch.
Make certain no bare wires are exposed outside the
connectors.
Fixture is designed for installation where it may come
in contact with insulation (Fig. 1).
Step 1 Using template supplied, scribe a circle on ceiling in
desired location.
H570R - 5 1/2"
H270R - 6 1/4"
Step 2 Accurately cut hole in ceiling.
Step 3 Pr
y. Pass
cable through opening and wir
re in accordance
with NEC or your local electrical code.
Follow Steps 1
through 4 under “Electrical Connection.”
Step 4 With clips seated properly in can (Figure 2), insert
HALO
®
AVERTISSEMENT: Pour des raisons de sécurité, lire et
comprendre toutes les instructions avant l’installation.
Avant l’installation des
couper le courant au niveau
de la boîte des fusibles ou du disjoncteur.
Les appareils d’éclairage encastrés Halo sont conçus en
conformité avec les exigences du dernier «Code national
de l’électricité» et sont
par les UL conformément
aux normes UL 1598. Avant de commencer à installer
quelque luminaire encastré que ce soit, veuillez
votre code régional de l’électricité. Ce code les
normes en matière de câblage pour votre région. Lisez-le
attentivement avant l’installation de l’appareil.
Installation
Remarque: Si le luminaire fonctionne à l’aide d’un inter-
rupteur mural, assurez-vous que le
d’alimentation noir
est connecté à l’interrupteur. NE PAS connecter le
d’alimentation blanc à l’interrupteur.
L’appareil est spécialement conçu pour les endroits
il peut entrer en contact avec des isolants. (Voir Fig. 1)
Étape 1 Dessiner un cercle sur le plafond à l'endroit
voulu à l'aide du gabarit.
H570R - 5 1/2"
H270R - 6 1/4"
Étape 2 Percer un trou dans le plafond de façon précise.
Étape 3 Procurer de courant élecrique à l'aide d'un
cäble souple seulement. Passer le cäble à travers
l'ouverture et faire le câblage de l'appareil conformé-
ment au code national de l'électricité ou a votre code
d'électricité local.. Suivre dans l’ordre les Étapes 1 à
4 de la section intitulée «Connexions électriques».
Paso 4 Con abrazaderas colocadas adecuadamente en
la caja metálica
1), inserte primero el portalám-
paras para uso en renovaciones en la caja de conex-
iones del techo.
Paso 5 Sujete el portalámparas contra el techo y empu-
je la abrazadera a través de la ranura de la caja
ADVERTENCIA: Por su propia seguridad, lea cuida-
dosamente y entienda las instrucciones antes de iniciar
la instalación. Antes de conectar la lámpara a la fuente
eléctrica, desconecte dicha fuente desde la caja de
fusibles o bajando la palanca principal. Las luminarias
empotradas Halo satisfacen las más recientes normas
de instalación eléctrica y cuentan con la
UL
al cumplir plenamente con UL 1598. Consulte las regula-
ciones eléctricas locales antes de instalar cualquier lumi-
naria empotrada. Estas regulaciones indican el tipo de
cableado autorizado en su localidad y deben ser estudi-
adas detenidamente antes de iniciar la instalación.
Instalación
Nota: Si la lámpara se encenderá mediante interruptor
de pared, asegúrese de conectar el cable negro de ali-
mentación al interruptor y NO CONECTE el cable blanco
dealimentación al interruptor.
Paso 1 Usando la plantilla, trace un circulo en el techo
en el lugar deseado.
H570R - 5 1/2"
H270R - 6 1/4"
Paso 2 Corte el en la pared con precisión
Paso 3 Proporcione la acometida de electricidad sólo
con el cable
Pase el cable por la abertura e
instale el portolámparas de acuerdo con el NEC
(Código Eléctrico Nacional) o su código elécrico local.
Siga los Pasos 1 a 4 descritos en "Connexión
Electrica".
Paso 4 Con abrazaderas colocadas adecuadamente
en la caja metálica
2), inserte primero el por-
talámparas para uso en renovaciones en la caja de
conexiones del techo.
Paso 5 Sujete el portalámparas contra el techo y empu-
je la abrazadera a través de la ranura de la caja
metálica (Figura 3).
Paso 6 Para cerrar la
abrazadera ade-
cuadamente, empuje
la parta plana contra
el lado de la caja
metálica (Figura 4)
Paso 7 Para sacarlo,
tire hacia abajo de la
abrazadera (Figura 5).
Paso 8 Instala el borde.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 703404
Risque de choc électrique
Couper le courant au fusible ou au dis-
joncteur avant l’installation ou toute
intervention
WARNING
Risk of Fire
Supply conductors (power wires)
connecting the fixture must be rated
minimum 90°C
If uncertain, consult an electrician
Risk of Electric Shock
Disconnect power at fuse or circuit
breaker before installing or servicing
Risk of Fire/Electric Shock
If not qualified, consult an electrician
Risque d’incendie
Les conducteurs d’alimentation (câbles
électriques) raccordant l’appareil
doivent supporter une température min-
imale de 90°C
En cas de doute, consulter un électricien
Riesgo de descarga eléctrica
Desconectar la electricidad en la caja
de fusibles o del disyuntor antes de
hacer la instalación o realizar tareas de
mantenimiento
Riesgo de incendio/ descarga eléctrica
Si usted no está habilitado, consulte
con un electricista
Riesgo de incendio
Los cables de alimentación (cables dis-
tribuidores de corriente) conectados a la
lámpara deben poder resistir temperat-
uras de 90°C como mínimo.
Si no está seguro, consulte con un electricista.
Risque d’incendie/de choc électrique
Consulter un spécialiste si non qualifié
ADVERTENCIA
AVERTISSEMENT
Recessed Downlight for Use
in Insulation
H270RICAT, H271RICAT, H272RICAT
H570RICAT, H571RICAT, H572RICAT
Éclairage direct encastré
pour isolantes
H270RICAT, H271RICAT, H272RICAT
H570RICAT, H571RICAT, H572RICAT
Luminaria Fija Empotrada para
uso en Material Aislante
H270RICAT, H271RICAT, H272RICAT
H570RICAT, H571RICAT, H572RICAT
FIG. 4
FIG. 5
FIG. 3
FIG. 2
FIG. 1
r
Step 5 re up against ceiling and push clip through
housing slot (Figure 3).
Step 6 T
can (Figure 4).
Step 7 To complete installation, push up clip with screwdriver
re 5).
Step 8 Install trim.
NOTE In areas where excessive ceiling vibration can occur, we
suggest you use a 1/4-14x1/2" pan HD sheet metal
scr
re
housing. Drive the screw through the hole in the spring
clip and into the housing slot.
Installation for AIR-TITE™ Construction
HALO AIR-TITE™ housings
under ASTM E283
are supplied with a pre-installed gasket or supplied with
a ready-to-install self adhesive gasket. To complete the
AIR-TITE installation of the ready-to-install gasket:
Step 1. Lay gasket
and peel protective paper back-
ing from gasket to expose adhesive side.
Step 2. Apply supplied gasket to ceiling lip and wrap
gasket around inside of housing to form seal of
the ceiling opening or apply caulk per state/local
code. When properly installed, Halo AIR-TITE™
housings provide compliance with restricted air-
regulations.
California Title 24
Washington State Energy Code
New York Energy Conservation Construction Code
International Energy Conservation Code (IECC)
Electrical Connection
Make certain no bare wires are exposed outside the
wire nut connectors.
For housings with push-nut connectors:
- Strip insulation 1/2”
- Use 12-16 AWG stranded (stranded pattern 19 or
less)
- or use 12-18 AWG solid copper wire
Step 1.
Provide electrical service according to the
National Electrical Code" or your local electrical code
from a suitable junction box to the wiring box (locat-
ed on the plaster frame). Supply wire insulation must
be rated for at least 9C.
Step 2 Remove the wiring box cover.
Note: The wiring box will accept metal conduit or non-
metallic cable, but metal conduit must be used if your
electrical code requires it.
Flexible Metal conduit: Remove appropriate round
knock-out(s) and connect
conduit to wiring box with prop-
er connector(s) (not included).
Non-metallic cable: Complete connections as out-
lined in step 3 and slide cable into wire traps (Fig. 7).
Step 3 Connect supply wires to wires in fixture wiring
box with proper size wire nuts (not included) or
push wires into “push-in” connectors (included on
select models). Be sure to cover all bare current-
carrying conductors. Connect white to white; black
to black; and green or bare copper wire (from
electrical service) to bare copper wire
(in wiring
box).
Note: The ground wire at the service junction box
may need to be secured to a ground screw.
Step 4 Place wires and connections back in wiring
box and replace cover.
metálica (Figura 3).
Paso 6 Para cerrar la abrazadera adecuadamente,
empuje la parta plana contra el lado de la caja metáli-
ca (Figura 4)
Paso 7 Para sacarlo, tire hacia abajo de la abrazadera
(Figura 5).
Paso 8 Instala el borde.
Nota: En zonas donde se produzca una vibración excesi-
va del techo, sugerimos que use tornillo de cabeza plan
de 1/4 - 14 x 1/2" para metal para cerrar más las
abrazaderas de muelle contra la caja del portolámparas.
Introduzca el tornillo por el orificio en la abrazadera de
muelle y en la ranura de la caja.
Installation de AIR-TITE™ dans une nouvelle
construction
Les boîtiers AIR-TITE™ de HALO homologués par la
norme de l’ASTM E283 sont fournis avec un joint pré-
installé ou avec un joint auto-adhésif prêt à installer.
Pour terminer l’installation AIR-TITE du joint prêt à
installer:
Étape 1 Placer le joint à plat puis retirez le papier de
protection du joint d’exposer le côté adhésif.
Étape 2. Appliquer le joint fourni sur la languette du pla-
fond puis l’enrouler autour du boîtier
d’étanchéiser
l’ouverture à l’intérieur du plafond. Correctement instal-
lés, les boîtiers AIR-TITE™ de Halo assurent la confor-
mité par rapport aux réglementations relatives au
d’air restreint.
Code de l’énergie de l’Etat de Washington
Californie Titre 24
Code de la construction et des économies d’énergie
de New-York
Code international relatif aux économies d’énergie -
IECC
Raccordements Électriques
Éviter, à tout prix, que des
soient mis à nu à l’ex-
térieur des connecteurs d’écrous.
Pour les boîtiers à connecteurs à écrou capuchon :
- Retirez l’isolant sur1/2 po
- Utilisez un réseau sélectif planaire de 12-16 torsadé
(motif torsadé de 19 ou moins)
- ou utilisez un câble en cuivre solide pour réseau
sélectif planaire de 12-18
Étape 1 Effectuer les connexions conformément aux dis-
positions du Code national de l’électricité ou à
celles de votre code régional à partir d’une boîte
de jonction appropriée à la boîte de câblage
(sur le cadre en plâtre). L’isolant pour
d’ali-
mentation doit être
classé pour une température
minimale de 9 C.
Étape 2 Enlever le couvercle de la boîte de câblage.
Remarque: L’on peut utiliser un conduit métallique ou
un câble non métallique dans la boîte de câblage, mais l’u-
tilisation d’un conduit métallique est requise si votre code de
l’électricité l’exige.
Conduit métallique: Enlever les débouchures rondes
appropriées et connecter le conduit à la boîte de câblage à
l’aide des connecteurs appropriés (non compris).
Câble non métallique: Effectuer les connexions
indiquées à l’étape 3 et insérer le câble dans les con-
necteurs (voir 4).
Étape 3 Connecter les
de l’alimentation à ceux de la
boîte de jonction de l’appareil d’éclairage au moyen de
connecteurs de de la taille appropriée (non compris)
ou insérer les
dans les connecteurs « à poussée »
(accompagnant certains modèles). S’assurer de couvrir
tous les conducteurs nus sous tension. Raccorder le
blanc au blanc, le noir au noir et le vert ou le
nu en cuivre (du réseau d’électricité) au nu en cuivre
(de la boîte de jonction de l’appareil d’éclairage).
Remarque: Il se peut que le
de mise à la terre de la
boîte de jonction doive être
à une vis de mise à la
terre.
Étape 4 Insérer tous les
et toutes les connexions dans
la boîte de câblage. Remettre le couvercle.
Installation de AIR-TITE™ dans une nouvelle
construction
Les boîtiers AIR-TITE™ de HALO homologués par la
norme de l’ASTM E283 sont fournis avec un joint pré-
installé ou avec un joint auto-adhésif prêt à installer.
Nota: En zonas donde se produzca una vibración excesi-
va del techo, sugerimos que use tornillo de cabeza
plan de 1/4 - 14 x 1/2" para metal para cerrar más
las abrazaderas de muelle contra la caja del por-
tolámparas. Introduzca el tornillo por el orificio en la
abrazadera de muelle y en la ranura de la caja.
Instalación para AIR-TITE™ en
construcciones nuevas
Los alojamientos HALO AIR-TITE™,
bajo
ASTM E283, son suministrados bien sea con una empa-
quetadura ya instalada o con una autoadhesiva lista para
ser colocada. Para completar la instalación de la empa-
quetadura lista para ser colocada:
Paso 1. Coloque la empaquetadura en posición plana y
despegue el papel protector de respaldo de la misma
para exponer el lado adhesivo.
Paso 2. Pegue la empaquetadura suministrada al rebor-
de del cielo raso y envuelva ésta alrededor de la parte
interna del alojamiento para formar un sello en la abertu-
ra del cielo raso. Cuando están correctamente instala-
dos, los alojamientos AIR-TITE™ cumplen con las regu-
laciones referentes al
de aire restringido.
Código de Energía del Estado de Washington
California Título 24
Codigo de Construcción -Conservación de Energía- de
Nueva York
Código Internacional de Conservación
de Energía
Conexión Eléctrica
No deje ningún cable suelto o desnudo alrededor de
los cables conectados.
Para cubiertas con conectores a presión:
Quitar 1/2" del aislamiento
Utilizar cable trenzado calibre 12-16, según la Escala
americana para calibres de alambre AWG (patrón de
trenzado de 19 o menos)
- O utilizar un alambre de cobre macizo calibre 12-18
AWG
Paso 1 Asegure que los cables del cielo raso donde insta-
la la mpara esn conectados a una caja de distribu-
ción eléctrica en conformidad con las normas locales
para instalaciones eléctricas. El cable de alimentación en
el cielo raso debe poder resistir temperaturas de 90° C
como mínimo.
Paso 2 Retire la tapa de la caja de conexiones del por-
talámpara.
Nota: La caja de conexiones del portalámpara aceptará
cables conductores metálicos o no metálicos, pero si las
normas de electricidad locales lo exigen, debe usar cable
conductor metálico.
Cable conductor metálico: Desprenda mediante presión
las placas circulares necesarias y conecte el cable del
cielo raso a las conexiones del portalámpara. Utilice
conos plásticos de conexión eléctrica para unir los cables
(no incluidos en el modelo).
Cable no metálico: complete las conexiones tal como se
indica en el paso 3 e inserte el cable en la trampa (Fig. 4).
Paso 3 Conecte los cables de alimentación a los cables
de la caja de conexiones del portalámpara usando
conos plásticos de conexión eléctrica de tamaño
apropiado (no incluidos) o inserte los cables dentro de
los conectores “a presión” (incluidos en ciertos mode-
los). Asegúrese de cubrir todos los cables desnudos
conductores de corriente. Conecte el blanco con el
blanco, el negro con el negro y el verde o el cable
desnudo de cobre (del servicio eléctrico) al cable
desnudo de cobre (de la caja de conexiones).
Nota: Probablemente deba atornillar el cable de tierra de
la caja de distribución eléctrica a un tornillo de tierra.
Paso 4 Reacomode todos los cables en la caja de
conexiones del portalámpara y vuelva a colocar la tapa
de la misma.
Instalación para AIR-TITE™ en
construcciones nuevas
Los alojamientos HALO AIR-TITE™,
bajo
ASTM E283, son suministrados bien sea con una empa-
quetadura ya instalada o con una autoadhesiva lista para
ser colocada. Para completar la instalación de la empa-
quetadura lista para ser colocada:
Paso 1. Coloque la empaquetadura en posición plana y
despegue el papel protector de respaldo de la misma
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 70340
HALO
®
Lamping Information
H270RICAT, H570RICAT
G24q-1/GX24-1 socket for one 13W DTT* or
13W TTT* 4 pin compact fluorescent lamp.
Generic 13W Lamp Designations (by others)
DTT: CFQ13W/G24q 2700K / 82 CRI
CFQ13W/G24q 3000K / 82CRI
TTT: CFTR13W/GX24q 2700K / 82 CRI
CFTR13W/GX24q 3000K / 82 CRI
H271RICAT, H571RICAT
G24q-2/GX24-2 socket for one 18W DTT* or
18W TTT* 4 pin compact fluorescent lamp.
Generic 18W Lamp Designations (by others)
DTT: CFQ18W/G24q 2700K / 82 CRI
CFQ18W/G24q 3000K / 82CRI
TTT: CFTR18W/GX24q 2700K / 82 CRI
CFTR18W/GX24q 3000K / 82 CRI
H272RICAT, H572RICAT
G24q-3/GX24-3 socket for one 26W DTT* or
26W TTT* 4 pin compact fluorescent lamp.
Generic 26W Lamp Designations (by others)
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
*DTT = Double Twin Tube; TTT = Triple Twin Tube
Ballast Replacement
NOTE: Ballast should be replaced by a qualified electri-
cian
Step 1. Remove trim.
To release housing, pull down on clip
(Figure 3).
Step 3.Disconnect ballast from input wiring and lam-
pholder leads (leads are terminated with either
wire nuts or push release connectors on ballast).
Step 4.Remove outer junction box cover with ballast
attached by releasing spring clip.
Step 5. Replace ballast with a factory approved,
ballast.
Step 6. Reinstall ballast by reversing steps 1 through 4
Pour terminer l’installation AIR-TITE du joint prêt à
installer:
Étape 1 Placer le joint à plat puis retirez le papier de
protection du joint afin d’exposer le côté adhésif.
Étape 2. Appliquer le joint fourni sur la languette du pla-
fond puis l’enrouler autour du boîtier afin d’étanchéiser
l’ouverture à l’intérieur du plafond. Correctement instal-
lés, les boîtiers AIR-TITE™ de Halo assurent la confor-
mité par rapport aux réglementations relatives au flux
d’air restreint.
Code de l’énergie de l’Etat de Washington
Californie Titre 24
Code de la construction et des économies d’énergie
de New-York
Code international relatif aux économies d’énergie -
IECC
Renseignements sur les ampoules
H270RICAT, H570RICAT
Prise de G24q-1/GX24-1 pour une lampe fluorescente
compacte à 4 ergots avec un DTT* de 13W DTT* ou un
TTT* de 13W.Désignations de lampes génériques de
13W (par les autres)
DTT: CFQ13W/G24q 2700K / 82 CRI
CFQ13W/G24q 3000K / 82CRI
TTT: CFTR13W/GX24q 2700K / 82 CRI
CFTR13W/GX24q 3000K / 82 CRI
H271RICAT, H571RICAT
Prise G24q-2/GX24-2 pour une lampe fluorescente à 4
ergots avec un DTT* de 18W ou un TTT* de 18W.
Désignations de lampes génériques de 18W (par les
autres)
DTT: CFQ18W/G24q 2700K / 82 CRI
CFQ18W/G24q 3000K / 82CRI
TTT: CFTR18W/GX24q 2700K / 82 CRI
CFTR18W/GX24q 3000K / 82 CRI
H272ICAT, H572RICAT
Prise G24q-3/GX24-3 pour une lampe fluorescente à 4
ergots avec un DTT* de 26W ou un TTT* de 26W.
Désignations de lampes génériques de 26W (par les
autres)
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
*DTT = Double Twin Tube (Double tuyau jumeau)
TTT = Triple Twin Tube (Triple tuyau jumeau)
Remplacement du ballast
NOTA: Le ballast doit être remplacé par un électricien
qualifié
Étape 1. Enlevez la garniture et abaissez le caisson
du cadre à sceller en dévissant les trois vis (Fig. 6).
Étape 2. Retirez le couvercle intérieur de la boite à
bornes en relâchant le ressort.
Étape 3. Débranchez le ballast du câblage d’entrée et
des fils de sortie de la douille (les fils de sortie sont
raccordés au ballast avec des serre-fils ou des con-
necteurs de poussée-déclenchement).
Étape 4. Retirez le couvercle extérieur de la boite à
bornes avec le ballast accroché en relâchant le
ressort.
Étape 5. Remplacez le ballast avec un ballast de pièce
d’origine qui est homologué.
Étape 6. Réinstallez le ballast en inversant les étapes 1
jusqu’à 4.
para exponer el lado adhesivo.
Paso 2. Pegue la empaquetadura suministrada al rebor-
de del cielo raso y envuelva ésta alrededor de la parte
interna del alojamiento para formar un sello en la
abertura del cielo raso. Cuando están correctamente
instalados, los alojamientos AIR-TITE™ cumplen con
las regulaciones referentes al flujo de aire restringido.
Código de Energía del Estado de Washington
California Título 24
Codigo de Construcción -Conservación de Energía-
de Nueva York
Código Internacional de Conservación
de Energía
Información sobre los bombillos
H270ICAT, H570RICAT
Portalámparas G24q-1/GX24-1 para una mpara fluores-
cente compacta de 4 pines 13W DTT* o 13W TTT.
mparas genéricas de 13W de otras marcas (por otros)
DTT: CFQ13W/G24q 2700K / 82 CRI
CFQ13W/G24q 3000K / 82 CRI
TTT: CFTR13W/GX24q 2700K / 82 CRI
CFTR13W/GX24q 3000K / 82 CRI
H271ICAT, H571RICAT
Portalámparas G24q-2/GX24-2 para una lámpara fluo-
rescente compacta de 4 pines 18W DTT* o 18W TTT.
Lámparas genéricas de 18W de otras marcas (por otros)
DTT: CFQ18W/G24q 2700K / 82 CRI
CFQ18W/G24q 3000K / 82 CRI
TTT: CFTR18W/GX24q 2700K / 82 CRI
CFTR18W/GX24q 3000K / 82 CRI
H272ICAT, H572RICAT
Portalámparas G24q-3/GX24-3 para una lámpara fluo-
rescente compacta de 4 pines 26W DTT* o 26W
TTT. Lámparas genéricas de 26W de otras marcas (por
otros)
DTT: CFQ26W/G24q 2700K / 82 CRI
CFQ26W/G24q 3000K / 82 CRI
TTT: CFTR26W/GX24q 2700K / 82 CRI
CFTR26W/GX24q 3000K / 82 CRI
* DTT = Tubo gemelo doble
TTT = Tubo gemelo triple
Reemplazo de balasto
NOTA: El balasto debe ser reemplazado por un elec-
tricista calificado.
Paso 1. Retire la lámpara y la carcasa extraíble de la
estructura de yeso, retirando tres tornillos (Fig. 6).
Paso 2. Retire la cubierta de la caja de empalmes interi-
or quitando el resorte.
Paso 3. Desconecte el balasto del alambrado de entrada
y los cables conductores del portalámpara (los cables
conductores terminan ya sea en tuercas de alambre o
conectores de liberación a presión sobre el balasto).
Paso 4. Retire la cubierta de la caja de empalmes exteri-
or con el balasto adjunto quitando el resorte.
Paso 5. Reemplace el balasto por uno aprobado de
fábrica.
Paso 6. uelva a instalar el balasto invirtiendo los pasos
del 1 al 4.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 703404
HALO
®

Transcripción de documentos

HALO® Recessed Downlight for Use Éclairage direct encastré in Insulation pour isolantes H270RICAT, H271RICAT, H272RICAT H570RICAT, H571RICAT, H572RICAT H270RICAT, H271RICAT, H272RICAT H570RICAT, H571RICAT, H572RICAT WARNING Luminaria Fija Empotrada para uso en Material Aislante H270RICAT, H271RICAT, H272RICAT H570RICAT, H571RICAT, H572RICAT AVERTISSEMENT Risk of Fire Supply conductors (power wires) connecting the fixture must be rated minimum 90°C If uncertain, consult an electrician Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing Risk of Fire/Electric Shock If not qualified, consult an electrician WARNING: For your safety read and understand instructions completely before starting installation. Before wiring to power supply, turn off electricity at the fuse or circuit breaker box. Halo recessed res are designed to meet the latest NEC requirements and are UL listed in full compliance with UL 1598. Before attempting installare check your local electrical tion of any recessed code. This code sets the wiring standards for your locality and should be carefully studied before starting. ADVERTENCIA Risque d’incendie Les conducteurs d’alimentation (câbles électriques) raccordant l’appareil doivent supporter une température minimale de 90°C Riesgo de incendio Los cables de alimentación (cables distribuidores de corriente) conectados a la lámpara deben poder resistir temperaturas de 90°C como mínimo. Si no está seguro, consulte con un electricista. Risque de choc électrique Couper le courant au fusible ou au disjoncteur avant l’installation ou toute intervention Riesgo de descarga eléctrica Desconectar la electricidad en la caja de fusibles o del disyuntor antes de hacer la instalación o realizar tareas de mantenimiento En cas de doute, consulter un électricien Risque d’incendie/de choc électrique Consulter un spécialiste si non qualifié AVERTISSEMENT: Pour des raisons de sécurité, lire et comprendre toutes les instructions avant l’installation. couper le courant au niveau Avant l’installation des de la boîte des fusibles ou du disjoncteur. Riesgo de incendio/ descarga eléctrica Si usted no está habilitado, consulte con un electricista ADVERTENCIA: Por su propia seguridad, lea cuidadosamente y entienda las instrucciones antes de iniciar la instalación. Antes de conectar la lámpara a la fuente Les appareils d’éclairage encastrés Halo sont conçus en eléctrica, desconecte dicha fuente desde la caja de conformité avec les exigences du dernier «Code national fusibles o bajando la palanca principal. Las luminarias de l’électricité» et sont par les UL conformément empotradas Halo satisfacen las más recientes normas aux normes UL 1598. Avant de commencer à installer Housing Installation UL de instalación eléctrica y cuentan con la al cumplir plenamente con UL 1598. Consulte las regulare is to be switched from wall switch, make quelque luminaire encastré que ce soit, veuillez Note: If les ciones eléctricas locales antes de instalar cualquier lumisure black power supply wire is connected to the switch. votre code régional de l’électricité. Ce code normes en matière de câblage pour votre région. Lisez-le naria empotrada. Estas regulaciones indican el tipo de DO NOT connect the white supply wire to the switch. attentivement avant l’installation de l’appareil. cableado autorizado en su localidad y deben ser estudi• Make certain no bare wires are exposed outside the Installation adas detenidamente antes de iniciar la instalación. connectors. Remarque: Si le luminaire fonctionne à l’aide d’un interInstalación • Fixture is designed for installation where it may come rupteur mural, assurez-vous que le d’alimentation noir Nota: Si la lámpara se encenderá mediante interruptor in contact with insulation (Fig. 1). est connecté à l’interrupteur. NE PAS connecter le de pared, asegúrese de conectar el cable negro de aliStep 1 Using template supplied, scribe a circle on ceiling in d’alimentation blanc à l’interrupteur. mentación al interruptor y NO CONECTE el cable blanco desired location. • L’appareil est spécialement conçu pour les endroits où dealimentación al interruptor. H570R - 5 1/2" il peut entrer en contact avec des isolants. (Voir Fig. 1) H270R - 6 1/4" Paso 1 Usando la plantilla, trace un circulo en el techo Étape 1 Dessiner un cercle sur le plafond à l'endroit en el lugar deseado. Step 2 Accurately cut hole in ceiling. voulu à l'aide du gabarit. H570R - 5 1/2" H570R 5 1/2" y. Pass Step 3 Pr H270R - 6 1/4" H270R - 6 1/4" cable through opening and wir re in accordance Paso 2 Corte el en la pared con precisión with NEC or your local electrical code. Follow Steps 1 Étape 2 Percer un trou dans le plafond de façon précise. through 4 under “Electrical Connection.” Paso 3 Proporcione la acometida de electricidad sólo Étape 3 Procurer de courant élecrique à l'aide d'un Pase el cable por la abertura e con el cable Step 4 With clips seated properly in can (Figure 2), insert cäble souple seulement. Passer le cäble à travers instale el portolámparas de acuerdo con el NEC l'ouverture et faire le câblage de l'appareil conformé(Código Eléctrico Nacional) o su código elécrico local. ment au code national de l'électricité ou a votre code Siga los Pasos 1 a 4 descritos en "Connexión FIG. 1 d'électricité local.. Suivre dans l’ordre les Étapes 1 à Electrica". 4 de la section intitulée «Connexions électriques». Paso 4 Con abrazaderas colocadas adecuadamente en Paso 4 Con abrazaderas colocadas adecuadamente 2), inserte primero el poren la caja metálica la caja metálica 1), inserte primero el portalámtalámparas para uso en renovaciones en la caja de paras para uso en renovaciones en la caja de conexconexiones del techo. iones del techo. Paso 5 Sujete el portalámparas contra el techo y empuje la abrazadera a través de la ranura de la caja FIG. 2 FIG. 3 FIG. 4 Paso 5 Sujete el portalámparas contra el techo y empuje la abrazadera a través de la ranura de la caja metálica (Figura 3). FIG. 5 Paso 6 Para cerrar la abrazadera adecuadamente, empuje la parta plana contra el lado de la caja metálica (Figura 4) Paso 7 Para sacarlo, tire hacia abajo de la abrazadera (Figura 5). Paso 8 Instala el borde. Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 703404 HALO® r Step 5 metálica (Figura 3). re up against ceiling and push clip through housing slot (Figure 3). Step 6 T can (Figure 4). Step 7 To complete installation, push up clip with screwdriver re 5). Step 8 Install trim. NOTE In areas where excessive ceiling vibration can occur, we suggest you use a 1/4-14x1/2" pan HD sheet metal re scr housing. Drive the screw through the hole in the spring clip and into the housing slot. Installation for AIR-TITE™ Construction HALO AIR-TITE™ housings under ASTM E283 are supplied with a pre-installed gasket or supplied with a ready-to-install self adhesive gasket. To complete the AIR-TITE installation of the ready-to-install gasket: and peel protective paper backStep 1. Lay gasket ing from gasket to expose adhesive side. Step 2. Apply supplied gasket to ceiling lip and wrap gasket around inside of housing to form seal of the ceiling opening or apply caulk per state/local code. When properly installed, Halo AIR-TITE™ housings provide compliance with restricted airregulations. • • • • California Title 24 Washington State Energy Code New York Energy Conservation Construction Code International Energy Conservation Code (IECC) Electrical Connection • Make certain no bare wires are exposed outside the wire nut connectors. • For housings with push-nut connectors: - Strip insulation 1/2” - Use 12-16 AWG stranded (stranded pattern 19 or less) - or use 12-18 AWG solid copper wire Step 1. Provide electrical service according to the “National Electrical Code" or your local electrical code from a suitable junction box to the wiring box (located on the plaster frame). Supply wire insulation must be rated for at least 90˚C. Step 2 Remove the wiring box cover. Note: The wiring box will accept metal conduit or nonmetallic cable, but metal conduit must be used if your electrical code requires it. Flexible Metal conduit: Remove appropriate round knock-out(s) and connect conduit to wiring box with proper connector(s) (not included). Non-metallic cable: Complete connections as outlined in step 3 and slide cable into wire traps (Fig. 7). Step 3 Connect supply wires to wires in fixture wiring box with proper size wire nuts (not included) or push wires into “push-in” connectors (included on select models). Be sure to cover all bare currentcarrying conductors. Connect white to white; black to black; and green or bare copper wire (from electrical service) to bare copper wire (in wiring box). Note: The ground wire at the service junction box may need to be secured to a ground screw. Step 4 Place wires and connections back in wiring box and replace cover. Paso 6 Para cerrar la abrazadera adecuadamente, empuje la parta plana contra el lado de la caja metálica (Figura 4) Paso 7 Para sacarlo, tire hacia abajo de la abrazadera (Figura 5). Paso 8 Instala el borde. Nota: En zonas donde se produzca una vibración excesiva del techo, sugerimos que use tornillo de cabeza plan de 1/4 - 14 x 1/2" para metal para cerrar más las abrazaderas de muelle contra la caja del portolámparas. Introduzca el tornillo por el orificio en la abrazadera de muelle y en la ranura de la caja. Instalación para AIR-TITE™ en construcciones nuevas Nota: En zonas donde se produzca una vibración excesiva del techo, sugerimos que use tornillo de cabeza plan de 1/4 - 14 x 1/2" para metal para cerrar más las abrazaderas de muelle contra la caja del portolámparas. Introduzca el tornillo por el orificio en la abrazadera de muelle y en la ranura de la caja. Installation de AIR-TITE™ dans une nouvelle construction Los alojamientos HALO AIR-TITE™, bajo ASTM E283, son suministrados bien sea con una empaquetadura ya instalada o con una autoadhesiva lista para ser colocada. Para completar la instalación de la empaquetadura lista para ser colocada: Les boîtiers AIR-TITE™ de HALO homologués par la norme de l’ASTM E283 sont fournis avec un joint préinstallé ou avec un joint auto-adhésif prêt à installer. Pour terminer l’installation AIR-TITE du joint prêt à installer: Paso 2. Pegue la empaquetadura suministrada al reborde del cielo raso y envuelva ésta alrededor de la parte interna del alojamiento para formar un sello en la abertura del cielo raso. Cuando están correctamente instalados, los alojamientos AIR-TITE™ cumplen con las regude aire restringido. laciones referentes al • Código de Energía del Estado de Washington • California Título 24 • Codigo de Construcción -Conservación de Energía- de Nueva York • Código Internacional de Conservación de Energía Étape 1 Placer le joint à plat puis retirez le papier de protection du joint d’exposer le côté adhésif. Étape 2. Appliquer le joint fourni sur la languette du plad’étanchéiser fond puis l’enrouler autour du boîtier l’ouverture à l’intérieur du plafond. Correctement installés, les boîtiers AIR-TITE™ de Halo assurent la conformité par rapport aux réglementations relatives au d’air restreint. • Code de l’énergie de l’Etat de Washington • Californie Titre 24 • Code de la construction et des économies d’énergie de New-York • Code international relatif aux économies d’énergie IECC Raccordements Électriques soient mis à nu à l’ex• Éviter, à tout prix, que des térieur des connecteurs d’écrous. Pour les boîtiers à connecteurs à écrou capuchon : - Retirez l’isolant sur1/2 po - Utilisez un réseau sélectif planaire de 12-16 torsadé (motif torsadé de 19 ou moins) - ou utilisez un câble en cuivre solide pour réseau sélectif planaire de 12-18 Étape 1 Effectuer les connexions conformément aux dispositions du Code national de l’électricité ou à celles de votre code régional à partir d’une boîte de jonction appropriée à la boîte de câblage (sur le cadre en plâtre). L’isolant pour d’alimentation doit être classé pour une température minimale de 90° C. Étape 2 Enlever le couvercle de la boîte de câblage. Remarque: L’on peut utiliser un conduit métallique ou un câble non métallique dans la boîte de câblage, mais l’utilisation d’un conduit métallique est requise si votre code de l’électricité l’exige. Conduit métallique: Enlever les débouchures rondes appropriées et connecter le conduit à la boîte de câblage à l’aide des connecteurs appropriés (non compris). Câble non métallique: Effectuer les connexions indiquées à l’étape 3 et insérer le câble dans les connecteurs (voir 4). de l’alimentation à ceux de la Étape 3 Connecter les boîte de jonction de l’appareil d’éclairage au moyen de connecteurs de de la taille appropriée (non compris) ou insérer les dans les connecteurs « à poussée » (accompagnant certains modèles). S’assurer de couvrir tous les conducteurs nus sous tension. Raccorder le blanc au blanc, le noir au noir et le vert ou le nu en cuivre (du réseau d’électricité) au nu en cuivre (de la boîte de jonction de l’appareil d’éclairage). Remarque: Il se peut que le de mise à la terre de la boîte de jonction doive être à une vis de mise à la terre. et toutes les connexions dans Étape 4 Insérer tous les la boîte de câblage. Remettre le couvercle. Installation de AIR-TITE™ dans une nouvelle construction Les boîtiers AIR-TITE™ de HALO homologués par la norme de l’ASTM E283 sont fournis avec un joint préinstallé ou avec un joint auto-adhésif prêt à installer. Paso 1. Coloque la empaquetadura en posición plana y despegue el papel protector de respaldo de la misma para exponer el lado adhesivo. Conexión Eléctrica • No deje ningún cable suelto o desnudo alrededor de los cables conectados. • Para cubiertas con conectores a presión: Quitar 1/2" del aislamiento Utilizar cable trenzado calibre 12-16, según la Escala americana para calibres de alambre AWG (patrón de trenzado de 19 o menos) - O utilizar un alambre de cobre macizo calibre 12-18 AWG Paso 1 Asegure que los cables del cielo raso donde instalará la lámpara estén conectados a una caja de distribución eléctrica en conformidad con las normas locales para instalaciones eléctricas. El cable de alimentación en el cielo raso debe poder resistir temperaturas de 90° C como mínimo. Paso 2 Retire la tapa de la caja de conexiones del portalámpara. Nota: La caja de conexiones del portalámpara aceptará cables conductores metálicos o no metálicos, pero si las normas de electricidad locales lo exigen, debe usar cable conductor metálico. Cable conductor metálico: Desprenda mediante presión las placas circulares necesarias y conecte el cable del cielo raso a las conexiones del portalámpara. Utilice conos plásticos de conexión eléctrica para unir los cables (no incluidos en el modelo). Cable no metálico: complete las conexiones tal como se indica en el paso 3 e inserte el cable en la trampa (Fig. 4). Paso 3 Conecte los cables de alimentación a los cables de la caja de conexiones del portalámpara usando conos plásticos de conexión eléctrica de tamaño apropiado (no incluidos) o inserte los cables dentro de los conectores “a presión” (incluidos en ciertos modelos). Asegúrese de cubrir todos los cables desnudos conductores de corriente. Conecte el blanco con el blanco, el negro con el negro y el verde o el cable desnudo de cobre (del servicio eléctrico) al cable desnudo de cobre (de la caja de conexiones). Nota: Probablemente deba atornillar el cable de tierra de la caja de distribución eléctrica a un tornillo de tierra. Paso 4 Reacomode todos los cables en la caja de conexiones del portalámpara y vuelva a colocar la tapa de la misma. Instalación para AIR-TITE™ en construcciones nuevas Los alojamientos HALO AIR-TITE™, bajo ASTM E283, son suministrados bien sea con una empaquetadura ya instalada o con una autoadhesiva lista para ser colocada. Para completar la instalación de la empaquetadura lista para ser colocada: Paso 1. Coloque la empaquetadura en posición plana y despegue el papel protector de respaldo de la misma Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 70340 HALO® Lamping Information H270RICAT, H570RICAT G24q-1/GX24-1 socket for one 13W DTT* or 13W TTT* 4 pin compact fluorescent lamp. Generic 13W Lamp Designations (by others) DTT: CFQ13W/G24q 2700K / 82 CRI CFQ13W/G24q 3000K / 82CRI TTT: CFTR13W/GX24q 2700K / 82 CRI CFTR13W/GX24q 3000K / 82 CRI H271RICAT, H571RICAT G24q-2/GX24-2 socket for one 18W DTT* or 18W TTT* 4 pin compact fluorescent lamp. Generic 18W Lamp Designations (by others) DTT: CFQ18W/G24q 2700K / 82 CRI CFQ18W/G24q 3000K / 82CRI Pour terminer l’installation AIR-TITE du joint prêt à installer: Étape 1 Placer le joint à plat puis retirez le papier de protection du joint afin d’exposer le côté adhésif. Étape 2. Appliquer le joint fourni sur la languette du plafond puis l’enrouler autour du boîtier afin d’étanchéiser l’ouverture à l’intérieur du plafond. Correctement installés, les boîtiers AIR-TITE™ de Halo assurent la conformité par rapport aux réglementations relatives au flux d’air restreint. • Code de l’énergie de l’Etat de Washington • Californie Titre 24 • Code de la construction et des économies d’énergie de New-York • Code international relatif aux économies d’énergie IECC TTT: CFTR18W/GX24q 2700K / 82 CRI CFTR18W/GX24q 3000K / 82 CRI H272RICAT, H572RICAT Renseignements sur les ampoules H270RICAT, H570RICAT G24q-3/GX24-3 socket for one 26W DTT* or 26W TTT* 4 pin compact fluorescent lamp. Generic 26W Lamp Designations (by others) Prise de G24q-1/GX24-1 pour une lampe fluorescente compacte à 4 ergots avec un DTT* de 13W DTT* ou un TTT* de 13W.Désignations de lampes génériques de 13W (par les autres) DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI DTT: TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI TTT: *DTT = Double Twin Tube; TTT = Triple Twin Tube Prise G24q-2/GX24-2 pour une lampe fluorescente à 4 ergots avec un DTT* de 18W ou un TTT* de 18W. Désignations de lampes génériques de 18W (par les autres) DTT: CFQ18W/G24q 2700K / 82 CRI CFQ18W/G24q 3000K / 82CRI TTT: CFTR18W/GX24q 2700K / 82 CRI CFTR18W/GX24q 3000K / 82 CRI CFQ13W/G24q 2700K / 82 CRI CFQ13W/G24q 3000K / 82CRI CFTR13W/GX24q 2700K / 82 CRI CFTR13W/GX24q 3000K / 82 CRI H271RICAT, H571RICAT Ballast Replacement NOTE: Ballast should be replaced by a qualified electrician Step 1. Remove trim. To release housing, pull down on clip (Figure 3). Step 3.Disconnect ballast from input wiring and lampholder leads (leads are terminated with either wire nuts or push release connectors on ballast). Step 4.Remove outer junction box cover with ballast attached by releasing spring clip. Step 5. Replace ballast with a factory approved, ballast. Step 6. Reinstall ballast by reversing steps 1 through 4 H272ICAT, H572RICAT Prise G24q-3/GX24-3 pour une lampe fluorescente à 4 ergots avec un DTT* de 26W ou un TTT* de 26W. Désignations de lampes génériques de 26W (par les autres) DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI *DTT = Double Twin Tube (Double tuyau jumeau) TTT = Triple Twin Tube (Triple tuyau jumeau) Remplacement du ballast NOTA: Le ballast doit être remplacé par un électricien qualifié Étape 1. Enlevez la garniture et abaissez le caisson du cadre à sceller en dévissant les trois vis (Fig. 6). Étape 2. Retirez le couvercle intérieur de la boite à bornes en relâchant le ressort. Étape 3. Débranchez le ballast du câblage d’entrée et des fils de sortie de la douille (les fils de sortie sont raccordés au ballast avec des serre-fils ou des connecteurs de poussée-déclenchement). Étape 4. Retirez le couvercle extérieur de la boite à bornes avec le ballast accroché en relâchant le ressort. para exponer el lado adhesivo. Paso 2. Pegue la empaquetadura suministrada al reborde del cielo raso y envuelva ésta alrededor de la parte interna del alojamiento para formar un sello en la abertura del cielo raso. Cuando están correctamente instalados, los alojamientos AIR-TITE™ cumplen con las regulaciones referentes al flujo de aire restringido. • Código de Energía del Estado de Washington • California Título 24 • Codigo de Construcción -Conservación de Energíade Nueva York • Código Internacional de Conservación de Energía Información sobre los bombillos H270ICAT, H570RICAT Portalámparas G24q-1/GX24-1 para una lámpara fluorescente compacta de 4 pines 13W DTT* o 13W TTT. Lámparas genéricas de 13W de otras marcas (por otros) DTT: TTT: CFQ13W/G24q 2700K / 82 CRI CFQ13W/G24q 3000K / 82 CRI CFTR13W/GX24q 2700K / 82 CRI CFTR13W/GX24q 3000K / 82 CRI H271ICAT, H571RICAT Portalámparas G24q-2/GX24-2 para una lámpara fluorescente compacta de 4 pines 18W DTT* o 18W TTT. Lámparas genéricas de 18W de otras marcas (por otros) DTT: CFQ18W/G24q 2700K / 82 CRI CFQ18W/G24q 3000K / 82 CRI TTT: CFTR18W/GX24q 2700K / 82 CRI CFTR18W/GX24q 3000K / 82 CRI H272ICAT, H572RICAT Portalámparas G24q-3/GX24-3 para una lámpara fluorescente compacta de 4 pines 26W DTT* o 26W TTT. Lámparas genéricas de 26W de otras marcas (por otros) DTT: CFQ26W/G24q 2700K / 82 CRI CFQ26W/G24q 3000K / 82 CRI TTT: CFTR26W/GX24q 2700K / 82 CRI CFTR26W/GX24q 3000K / 82 CRI * DTT = Tubo gemelo doble TTT = Tubo gemelo triple Reemplazo de balasto NOTA: El balasto debe ser reemplazado por un electricista calificado. Paso 1. Retire la lámpara y la carcasa extraíble de la estructura de yeso, retirando tres tornillos (Fig. 6). Paso 2. Retire la cubierta de la caja de empalmes interior quitando el resorte. Paso 3. Desconecte el balasto del alambrado de entrada y los cables conductores del portalámpara (los cables conductores terminan ya sea en tuercas de alambre o conectores de liberación a presión sobre el balasto). Paso 4. Retire la cubierta de la caja de empalmes exterior con el balasto adjunto quitando el resorte. Paso 5. Reemplace el balasto por uno aprobado de fábrica. Paso 6. uelva a instalar el balasto invirtiendo los pasos del 1 al 4. Étape 5. Remplacez le ballast avec un ballast de pièce d’origine qui est homologué. Étape 6. Réinstallez le ballast en inversant les étapes 1 jusqu’à 4. Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801 703404
  • Page 1 1
  • Page 2 2
  • Page 3 3

Halo H272RICAT Instrucciones de operación

Tipo
Instrucciones de operación
Este manual también es adecuado para