Lutron Electronics RadioRA 2 Guía de instalación

Tipo
Guía de instalación
• ScrewTerminals:Usewith12AWG
(2.5mm
2
)or14AWG(1.5mm
2
)
solid copper wire only.DoNOT
usestrandedortwistedwire.
 Wrapwirearoundscrew
terminal.Tightensecurelyto
5in-lb(0.55N
m).
b. WireConnectors:
Preparewires.Whenmaking
wireconnections,followthe
recommendedstriplengthsand
combinationsforthesuppliedwire
connector.
NOTE: Wire connectors provided are suitable
for copper wire only.
Wire Connector:
•
Stripinsulation3/8
in(10
mm)for14
AWG
(1.5mm
2
)or12AWG(2.5mm
2
)wire.
• Stripinsulation7/16in(11mm)for
18AWG(0.75mm
2
)or16AWG
(1.0mm
2
)wire.
•
Usetojoinoneortwo14
AWG(1.5
mm
2
)or
12AWG
(2.5mm
2
)wireswithone18AWG
(0.75mm
2
)or16AWG(1.0mm
2
)wire.
 Forsingleandmulti-locationinstallations
seeWiring Diagrams.
4.Pushallwiresbackintothewallboxand
looselyfastenthecontroltothewallboxusing
thecontrolmountingscrewsprovided.Donot
pinchthewires.
5.AttachtheLutron®Claro®orSatinColors®
wallplateadapterandwallplate.See
Mounting Diagram.
a.Installwallplateadapterontofrontof
control(s).
b.Tightencontrolmountingscrewsuntil
wallplateadapterisflushtowall(donot
over-tighten).
c.Snapwallplateontowallplateadapter,and
verifythatcontrolisalignedproperly.
d.Ifcontrolsaremisaligned,loosenmounting
screwsappropriately.
6.Restorepower.Verifycorrectlocaloperation.
SeeDimmer/Fan OperationorSwitch
Operation.
* Dimmer:
RRD-6D, -6NA, -10D, -10ND
(120V~50/60Hz)
RRD-F6AN-DV (120/277V~50/60Hz)
* Switch:
RRD-
8ANS
(120V~50/60Hz)
RRD-8S-DV (120-277V~50/60Hz)
* Remote Switches:
RD-RS (120
V~
50/60Hz)
RD-RS-277 (277
V~
50/60Hz)
Installation Instructions
Please Read Before Installing
Multigang Installations
 Inmultiganginstallations,severalcontrolsare
groupedhorizontallyinonemultigangwallbox.
 Whencombiningcontrolsinawallbox,deratingis
required;however,noderatingisrequiredforfan
speedcontrolsandremotedimmers/switches.
Derating Chart
Control Load Type End of
Gang
Middle
of Gang
-6D
Incand. 500W 400W
MLV
400W/
500VA
300W/
400VA
-6NA
Incand./ELV 500W 400W
MLV
400W/
500VA
300W/
400VA
-10D,
-10ND
Incand. 800W 650W
MLV
600W/
800VA
500W/
650VA
-F6AN-DV*
3-wire
Fluorescent/
LED
5A 3.5A
50
ballasts
35
ballasts
-2ANF CeilingFan 2A 2A
-8ANS
Lighting 6.5A 5A
Motor
1/4HP
5.8A
1/6HP
4.4A
-8S-DV
Lighting
8A
(2-gang)
7A
(3-gang)
7A
Motor
1/10HP
3A
* Themaximumloadforthe-F6AN-DViseitherthe
deratedloadorthenumberofballasts,whicheveris
LESS.
NOTE: -8ANS,-RD-277and-RS-277controls
havefinsthatneedtoberemovedformultigang
installations.-6D,-6NA,-10D,-10ND,-F6AN-DV,
-2ANF,-8S-DV,-RDand-RScontrolsdo not
havefinsthatneedtoberemovedformultigang
installations.
Troubleshooting Guide
LutronElectronicsCo.,Inc.
7200SuterRoad|Coopersburg,PA18036-1299
P/N044-319Rev.B09/2012
Important Notes
WARNING – Entrapment Hazard –
Toavoidtheriskofentrapment,serious
injury,ordeath,thesecontrolsmustnot
beusedtocontrolequipmentwhichisnotvisible
fromeverycontrollocationorwhichcouldcreate
hazardoussituationssuchasentrapmentifoperated
accidentally.Examplesofsuchequipmentwhich
mustnotbeoperatedbythesecontrolsinclude(but
arenotlimitedto)motorizedgates,garagedoors,
industrialdoors,microwaveovens,heatingpads,
etc.Itistheinstaller’sresponsibilitytoensurethat
theequipmentbeingcontrolledisvisiblefromevery
controllocationandthatonlysuitableequipmentis
connectedtothesecontrols.Failuretodosocould
resultinseriousinjuryordeath.
Codes:Installinaccordancewithalllocaland
nationalelectricalcodes.
Grounding:Whenno“groundingmeans”existin
wallbox,the2011NationalElectricalCode®(NEC®)
allowsacontroltobeinstalledasareplacementif
1)anonmetallic,noncombustiblefaceplateisused
withnonmetallicattachmentscrewsor2)thecircuit
isprotectedbyagroundfaultcircuitinterrupter
(GFCI).Wheninstallingacontrolaccordingtothese
methods,caporremovegreenwirebeforescrewing
controlintowallbox.
Neutral Wire:-6NA,-10ND,-F6AN-DV,-2ANF,
and-8ANSrequire aneutralwireconnectioninthe
wallboxwherethedimmer/switch/fancontrolisto
beinstalled.Ifaneutralwireconnectionisnot
availableinthewallbox,contactalicensedelectrician
forinstallation.
Environment:Ambientoperatingtemperature:32°F
to104°F(0°Cto40°C),0%to90%humidity,non-
condensing.Indooruseonly.
Spacing:Ifmountingonecontrolaboveanother,
leaveatleast4
½
in(114mm)verticalspace
betweenthem.
Wallplates:Lutron®Claro®andSatinColors®
wallplatesarerecommendedforbestcolormatch
andaestheticappearance.Donotpaintcontrolsor
wallplates.
Cleaning:Toclean,wipewithacleandampcloth.DO
NOTuseanychemicalcleaningsolutions.
Wallboxes: Lutronrecommendsusing3
½
in
(89mm)deepwallboxesforeasierinstallation.
Severalcontrolsmaybeinstalledinonemultigang
wallbox.SeeDerating Chart.
Remotes:Useonlyremotedimmers
(-RD/-RD-277)andremoteswitches
(-RS/-RS-277)withdimmers/switches/fanspeed
controls.Upto9-RD/-RD-277or-RS/-RS-277
maybeusedwithcontrols.Mechanical3-or4-way
switcheswillnotwork.
RF Device Placement:RFdimmers/switchesand
fancontrolsmustbelocatedwithin30ft(9m)ofan
RFSignalRepeater.Remotedimmers/switchesare
notrequiredtobewithinaspecificrangeof
arepeater.
ForsystemswithanRFsignalrepeater,
RFdimmers/switches/fanspeedcontrolscannotbe
controlledbythesystemuntiltheyareprogrammed
inasystemaccordingtothesystemSetup Guide.
English
Lutron,Claro,SatinColors,Maestro,Hi-lume,Ecosystem,Eco-10,RadioRA,and)areregisteredtrademarksandRadioRA2,CompactSE,andFASSaretrademarksofLutronElectronicsCo.,Inc.
NECisaregisteredtrademarkoftheNationalFireProtectionAssociation,Quincy,Massachusetts.
©2012LutronElectronicsCo.,Inc.
Mounting Diagram
Control
Mounting
Screws
Wallbox
Control
Included:
WireConnectors(1or5)
MountingScrews(2)
Adapter
Mounting
Screws
Wallplateadapterand
wallplatepurchased
separately.
Wallplate
Adapter
Wallplate
Technical Assistance:
U.S.A./Canada:1.800.523.9466|Mexico:+1.888.235.2910
Brazil:+55(11)3257-6745(M-F8:30to17:30BRT)|OtherCountries:+1.610.282.3800
24hoursaday,7daysaweek www.lutron.com
* Typical Power Consumption:
Dimmer / Switch / Fan Speed Control: 0.6 W
(Loadisoff,nightlightmodeenabled.)
Remote Dimmer / Switch: 0 W(Loadisoff.)
Installation
WARNING – Shock Hazard –
Toavoidtheriskofelectricshock
locateandremovefuseorlockcircuit
breakerintheOFFpositionbeforeproceeding.
WiringwithpowerONcouldresultinserious
injuryordeath.
1.TurnpowerOFFatfuseboxorcircuitbreaker.
2.Checktheinstallationforshortcircuitsbefore
installingcontrol(s).WithpowerOFF,install
standardmechanicalswitch(es)between
Hotandload.Restorepower.Iflightsor
fansdonotworkorabreakertrips,check
wiring.Correctwiringandcheckagain.Install
control(s)onlywhenshortisnolongerpresent.
WarrantyisvoidifcontrolisturnedONwitha
shortedcircuit.
3.Wirecontrolsaccordingtooneofthefollowing
options:
a. Terminals:Trimorstripwallboxwirestothe
lengthindicatedbythestripgaugeonthe
backofthecontrol.
• Push-InTerminals:Usewith
14AWG(1.5mm
2
)solid copper
wire only.DoNOTusestrandedor
twistedwire.
 Insertwiresfully.Toreleasewire,
insertsmall,flatscrewdriverinto
slotbelowpush-interminal.
Pushscrewdriverinwhilepulling
wireout.
OR
Eachcontrol
hasinsidefins
removed
Controlatmiddle
ofganghasallfins
removed
Do Not removeoutsidefinson
controlsattheendofgang
SingleLocationInstallation
1
withoutNeutral
-6D,-10D(120V ~)
Wiring Diagram 1
Green
Ground
Hot/Live
Neutral
Load
Dimmer
120V~
50/60Hz
For system Setup Guide and tools visit
www.lutron.com/radiora2
Load Specifications
Control Load Type Min. Load Max. Load
-6D
1
Incand. 50W 600W
MLV
2
50W/VA
450W/
600VA
-6NA
1
Incand./
ELV
2
5W 600W
MLV
2
5W/VA
450W/
600VA
-10D
1
Incand. 50W 1000W
MLV
2
50W/VA
800W/
1000VA
-10ND
1
Incand. 10W 1000W
MLV
2
10W/VA
800W/
1000VA
-F6AN-DV
3,4,5
3-wire
Fluorescent/
LED
0.05A 6A
1ballast 60ballasts
-2ANF
6
CeilingFan 0.083A 2A
-8ANS
7
Lighting 10W/VA 8A
Motor 0.08A
1/4HP
5.8A
-8S-DV
8,9
Lighting 40W/VA 8A
Motor 0.4A
1/10HP
3A
-RD
10
SeeDimmer
8.3A
-RS
10
SeeSwitch
-RD-277
11
SeeDimmer
-RS-277
11
SeeSwitch
1 Dimmer Load Type: -6D,-10Dand-10NDaredesignedforuse
withpermanentlyinstalledincandescent,magneticlow-voltage,
ortungstenhalogenonly.
-6NAisdesignedforusewithpermanentlyinstalledincandescent,
electroniclow-voltage,magneticlow-voltage,ortungsten
halogenonly.
Donotinstalldimmerstocontrolreceptaclesormotor-operated
appliances.Donotmixincandescent,halogen,MLV,orELVload
typesonadimmer.
2 Low-Voltage Applications:Use-6D,-10Dand-10NDwith
magnetic(coreandcoil)low-voltagetransformersonly.Notfor
usewithelectronic(solid-state)low-voltagetransformers.
Use-6NAwithdimmableelectronic(solid-state)ormagnetic
(coreandcoil)transformers.
Operationofalow-voltagecircuitwithlampsinoperativeor
removedmayresultintransformeroverheatingandpremature
failure.Lutronstronglyrecommendsthefollowing:
a.Donotoperatelow-voltagecircuitswithoutoperativelampsin
place.
b.Replaceburned-outlampsasquicklyaspossible.
c.Usetransformersthatincorporatethermalprotectionorfused
transformerprimarywindingstopreventtransformerfailure
duetoovercurrent.
3 Fluorescent Dimmer Load Type:
-F6AN-DVisdesignedforusewithpermanentlyinstalled3-wire
120V~or277V~linevoltagecontrolfluorescentballastsorLED
drivers.UseonlywithHi-lume®,Hi-lume®3D,Hi-lume®A-Series,
CompactSE
,Eco-10®,orEcoSystem®(H3D-,FDB-,ECO-,
HL3-,EC5-,L3D).DoNOTusewithanyotherballastsordrivers.
Donotinstalltocontrolreceptaclesormotor-operatedappliances.
4 Power Boosters / Load Interfaces: -6NA,-10ND,-F6AN-DV,
and-8ANScanbeusedtocontrolpowerboosters/ load
interfaces.Foralistofcompatiblepowerboosters/ load
interfacesseeLutronP/N369225.
5 Maximum Load: Themaximumloadforthe-F6AN-DViseither
thederatedloadorthenumberofballasts,whicheverisLESS.
6 Ceiling Fan Application (-2ANF):
• Usetocontrolonepaddle-typeceilingfan
(permanentsplit-capacitor).
•Usetheceilingfan’spullchaintosetitsspeedtothe
highestsetting.
•Donotusetocontrolfansthatuseshaded-polemotors
(i.e.bathexhaustfans).
•Donotusetocontrolfansthathaveintegratedfanspeed
controls(i.e.fansthathavearemotecontrol),unlessthe
integratedcontrolisremovedfromtheceilingfan.
•Donotconnecttoanyothermotor-operatedapplianceorto
anylightingloadtype.
•Donotusetocontrolafanlightingload(i.e.lightkit).
7 Switch Load Type -8ANS: -8ANSisdesignedforusewith
permanentlyinstalled120V~incandescent,magnetic
low-voltage,electroniclow-voltage,orfluorescentloadsand
withmotorloadsupto1/4HP(5.8A).
8 Switch Load Type -8S-DV: -8S-DVisdesignedforuse
withpermanentlyinstalled120V~incandescent,magnetic
low-voltage,electroniclow-voltage,fluorescent,ormotorloads;
or277V~magneticlow-voltageorfluorescentloads.
9 Shunt Capacitor (included): Some-8S-DVinstallations
mayrequiretheuseofashuntcapacitor.Thisisespecially
necessaryforloadtypessensitivetoleakagecurrent(i.e.
fluorescentballasts).Ifloadflickers,installashuntcapacitor.
Forshunt
capacitorinstallationseeWiring Diagram 4 or 8.
10 120 V~ Remote Dimmer / Switch: -RDand-RSaredesigned
forusewith120V~dimmers/switches.
11 277 V~ Remote Dimmer / Switch: -RD-277and-RS-277are
designedforusewith277V~dimmers/switches.DoNOTuse
withmotorloads.
1
Whenusingcontrolsinsinglelocationinstallations,tightentheblueterminalwithoutanywiresattached.
DONOTconnecttheblueterminaltoanyotherwiringortoground.
2
ShuntcapacitormustbeinstalledinsidetheloadfixtureorinaseparateJ-box.
3
Installonly1dimmer/switch/fanspeedcontrolpercircuit.Upto9remotedimmers/switchesmaybeconnectedtoa
dimmer/switch/fanspeedcontrol.Totalblueterminalwirelengthmaybeupto250ft(76m).
4
Neutralwiredimmers/switches/fanspeedcontrolsmustbeconnectedontheLoadsideofamulti-locationinstallation.
Lamp Replacement
WARNING – Shock Hazard –For
anyprocedureotherthanroutine
lampreplacement,powermustbe
disconnectedatthemainelectricalpanel.
WorkingwithpowerONcouldresultin
seriousinjuryordeath.
Foryoursafetyduringroutinelamp
replacement,removepowerfromthefixture(s)
bymovingtheFASS
switchintotheOFF
positiononthedimmer/switchandallremote
dimmers/switches.
Symptom Probable Cause and Action
Light/fandoesn’tturn
ON/OFFwhentapswitch
ondimmer/switch/fan
speedcontrolorremote
dimmer/switchispressed
Power not present
•CircuitbreakerOFFortripped.Performshortcircuitcheck.
• FASS
isintheOFFposition.MoveFASS
totheONposition.
Checkthedimmer/switch/fanspeedcontrolandalloftheremote
dimmers/switches.SeeLamp Replacement.
Wiring
•Wiresshorted.Makesuretheblueterminalisnotgroundedorshortedto
anyotherwires.
•Wiringerror.Checkwiringtobesureitagreeswithinstallationinstructions
andwiringdiagrams.
•For-8S-DV,increaseloadtomeettheappropriateminimumload
requirementoruseshuntcapacitoror-8ANS.SeeLoad Specifications.
Load is less than minimum load requirement
•Makesuretheconnectedloadmeetstheappropriateminimumload
requirementforthatcontrol.SeeLoad Specifications.
•For-8S-DV,increaseloadtomeettheappropriateminimumload
requirementoruseshuntcapacitoror-8ANS.SeeLoad Specifications.
Lamps burned out or not installed
•Replaceorinstalllamps.
Dioded lamps
•Ifdiodedlampsarebeingused,replacewithnon-diodedlamps.
Fan setting
•Makesurethefanissettoitshighestspeedusingthepull-chain.
Fan Speed Control Wrong Load Type
•Makesurethatonlyasingleceilingpaddlefan(permanentsplit-capacitor
motor)ratedat2Aorlessisconnectedtothecontrol.
•Makesurethatnolightingload(i.e.lightkit)isconnectedtothecontrol.
Loadflickersortapswitch
doesnotworkevenifload
isgreaterthan40W
(-8S-DVonly)
Leakage current
•Installashuntcapacitor.SeeWiring Diagram 4 or 8.
LightturnsONandOFF
continuouslyorlightsturnON
whentapswitchispressed,
thenturnOFF
Load does not meet the minimum load requirement
•Increaseloadtomeettheappropriateminimumloadrequirementforthat
control.SeeLoad Specifications.
•Installashuntcapacitorwith-8S-DV.SeeSeeWiring Diagram 4 or 8.
•For-8S-DV,increaseloadtomeettheappropriateminimumload
requirementoruseshuntcapacitoror-8ANS.See
Load Specifications.
Loadflickers
(-8S-DVonly)
Load does not meet the minimum load requirement
•Increaseloadtomeettheappropriateminimumloadrequirementforthat
control.SeeLoad Specifications.
•Installashuntcapacitor.SeeWiring Diagram 4 or 8.
Lights/Fansdon’tturnON/
OFFfromakeypad
Improper programming
•ProgramaccordingtothesystemSetup Guide.
Out of RF range
•Repositiontobewithin30ft(9m)ofanRFsignalrepeater.
Wiring
•Wiresshorted.Makesuretheblueterminalisnotgroundedorshortedto
anyotherwires.
•Wiringerror.Checkwiringtobesureitagreeswithinstallationinstructions
andwiringdiagrams.
Wallplateiswarm Solid-state control dissipation
•Solid-statedimmers/switches/fanspeedcontrolsinternallydissipate
about2%ofthetotalconnectedload.Itisnormalfordimmers/
switches/fanspeedcontrolstofeelwarmtothetouchduringoperation.
NOTE: Refer to the system SetupGuide for additional troubleshooting suggestions.
SingleLocationInstallation
1
withoutNeutral
-8S-DVwithoptionalshuntcapacitor
2

(120-277V~)
Wiring Diagram 4
Brass
Black
Blue
1
Green
Ground
Hot/Live
Neutral
Load
Switch
120-277V~
50/60Hz
Shunt
Capacitor
2
Optional
SingleLocationInstallation
1
withNeutral
-F6AN-DV(120/277V~)
Wiring Diagram 3
Brass
Black
Blue
1
Green
Ground
Hot/Live
Neutral
Lutron®
Ballast/
LEDDriver
Lutron®
Ballast/
LEDDriver
Dimmer
120/277V~
50/60Hz
Black
Orange
White
Orange
Silver
Black
Orange
White
Multi-LocationDimmerInstallation
3
withNeutral
4
-F6AN-DVwith-RDor-RD-277
(120/277V~)
Dimmer
Remote DimmerRemote Dimmer
NOTE: Dimmermustbeinstalledon
theloadsideofthecircuit.
Brass/
Red
Brass/
Red
Black
Blue
Green
Ground
Hot/Live
Neutral
120/277V~
50/60Hz
Black
Orange
White
Black
Orange
White
Brass
Black
Blue
GreenGreen
GroundGround
Orange
Silver
Black
Blue
Status LEDs
Indicatelightlevel;glowssoftly
asnightlightwhenloadisoff
Tapswitch
Tapon/off
Dimming Rocker
PresstoBrighten
orIncreaseSpeed
PresstoDim
orDecreaseSpeed
FASS
Front
Accessible
Service
Switch
Dimmer/Fan Operation
Switch Operation
Status LED
Indicateslightstatus;glowssoftly
asnightlightwhenloadisoff
Tapswitch
Tapon/off
FASS
Front
Accessible
Service
Switch
OR
-RD-277or
-RS-277only
OFF ON
Multi-LocationInstallation
3
withNeutral
4
-6NA,-10ND,and-2ANFwithRD-RD,and-8ANSwithRD-RS(120V~)
Brass
Silver
Black
Blue
Green
Ground
Load
Brass
Black
Blue
Green
Ground
Remote Dimmer/
Remote Switch
120V~
50/60Hz
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer/
Remote Switch
Dimmer / Switch /
Fan Speed Control
Wiring Diagram 6
Wiring Diagram 7
Wiring Diagram 8
SingleLocationInstallation
1
withNeutral
-6NA,-10ND,-2ANFand-8ANS(120V ~)
Wiring Diagram 2
Dimmer/Switch/
Fan Speed Control
Twist wire
connector tight.
Multi-LocationInstallation
3
withoutNeutral
-6D,-10Dwith-RD(120V~)
Brass
Black
Blue
Green
Ground
Load
Dimmer
/
Remote Dimmer
3
Brass
Black
Blue
Green
Ground
Remote Dimmer
/
Dimmer
3
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer
/
Dimmer
3
120V~
50/60Hz
NOTE: Dimmermay be installed in
any location inthecircuit.
Return to Factory Settings
NOTE: Returningadimmer/switch/fanspeedcontoltoitsfactorysettingswillremoveitfromthesystemand
eraseallprogrammingfromit.
Step 1 : Tripletapthetapswitchonacontrol.DONOTreleaseafterthethirdtap.
Step 2 : Keepthetapswitchpressedonthethirdtap(forapproximately3seconds)untiltheLEDsonthedimmer
starttoscrollupanddownquickly,ortheLEDontheswitchflashesquickly
Step 3 : Releasethetapswitchandimmediatelytripletapthetapswitchagain.TheLEDsonthedimmerwillscroll
upanddownslowly.TheLEDontheswitchwillflashslowly.
Thecontrolhasnowbeenreturnedtofactorysettingsandneedstobereprogrammedintoasystem.
Warranty: SeetheWarrantyenclosedwiththeproduct,orvisit
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
Multi-LocationInstallation
3
withoutNeutral
-8S-DVwith-RSor-RS-277andoptionalshuntcapacitor
2
(120 277V~)
Black
Blue
Green
Ground
Load
Switch / Remote
Switch
3
Black
Blue
Green
Ground
Remote Switch /
Switch
3
Brass/
Red
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Switch /
Switch
3
NOTE: Switchmaybeinstalledinany
locationinthecircuit.
Shunt
Capacitor
2
120–277V~
50/60Hz
Optional
Brass/
Red
Brass/
Red
NOTE: Dimmermustbeinstalled
ontheloadsideofthecircuit.
Designer-Style RF Maestro®
Dimmer
Shown
* Fan Speed Control:
RRD-2ANF (120
V~
50/60Hz)
* Remote Dimmers:
RD-RD (120
V~
50/60Hz)
RD-RD-277 (277
V~
50/60Hz)
Dimmer Switch
Remote
Switch
Remote
Dimmer
FanSpeed
Contol
Blue
1
Blue
1
Brass
Brass
Silver
Black
Black
Hot/Live
Neutral
120V~
50/60Hz
Green
Ground
Load
Wiring Diagram 5
Lutron®
Ballast/
LEDDriver
Lutron®
Ballast/
LEDDriver
Lutron,Claro,SatinColors,Maestro,Hi-lume,Ecosystem,Eco-10,RadioRAy)sonmarcasregistradas,yRadioRA2,CompactSEyFASSsonmarcasdeLutronElectronicsCo.,Inc.
NECesunamarcaregistradadelaNationalFireProtectionAssociation,Quincy,Massachusetts.
©2012LutronElectronicsCo.,Inc.
Retorno a la configuración de fábrica
NOTA: Elretornodeunatenuador/interruptor/controledevelocidaddeventiladorasuconfiguracióndefábrica
loremoverádelsistemayborrarátodasuprogramación.
Paso 1: Pulsetresvecesymantengaelinterruptordepresióndeuncontrol.NOsuelteelbotóndespuésdel
tercerpulso.
Paso 2 : Mantengapresionadoelinterruptordespuésdeltercerpulso(durante3segundosaproximadamente)
hastaquelosLEDsdelatenuadorseenciendanyapaguenrápidamenteensecuencia,oelLEDdel
interruptorparpadeerápidamente.
Paso 3 : Suelteelinterruptoreinmediatamentepúlselootrastresveces.LosLEDsdelatenuadorseencenderán
yapagaránlentamenteensecuencia.ElLEDdelinterruptorparpadearálentamente.
Elcontrolvolvióahoraasuconfiguacióndefábricaydeberáserreprogramadodentrodeunsistema.
Garantía: Consultelaseccióngarantíaqueseincluyejuntoconelproducto,ovisite:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
Asistencia técnica:
E.U.A./Canadá:1.800.523.9466|México:+1.888.235.2910
Brasil:+55(11)3257-6745(Lunes-Viernes8:30to17:30BRT)|Otrospaíses:+1.610.282.3800
24horasaldía,los7díasdelasemana www.lutron.com
Instalaciones con múltiples dispositivos
ADVERTENCIA – Peligro de descarga
eléctrica – Paraevitarla, ubiqueyretire
elfusibleoasegureeldisyuntoren
laposicióndeAPAGADOantesdeproceder.
CablearconlaalimentaciónENCENDIDA
podríacausarlesionesgravesolamuerte.
1.DESCONECTElaalimentaciónenlacajade
fusiblesoeneldisyuntor.
2.
Verifiquequenohayacortocircuitosenla
instalaciónantesdeinstalarel(los)control(es).
ConlaalimentaciónDESCONECTADA,instale
interruptoresmecánicosestándarentreel
vivoylacarga.Restablezcalaalimentación.
Silaslucesoventiladoresnofuncionano
undisyuntorsedispara,corrijaelcableadoy
verifiquenuevamente.Instaleel(los)control(es)
solamentecuandoyanohayacortocircuito.La
garantíaesnulasielcontrolseENCIENDEcon
uncortocircuito.
3.Cableeloscontrolesdeacuerdoconunade
lasopcionessiguientes:
a.
Terminales:
Recorteopeleloscablesdela
cajadeempotrarhastalamedidaindicada
enelreversodelcontrol.
• Terminalesdeinsertar:Use
únicamenteconcablesdecobre
sólidode1,5mm
2
(14AWG). NO
utilice cable trenzadoniretorcido.
 Insertecompletamenteloscables.
Parasoltarelcable,inserteun
destornilladorchatopequeñodentro
delaranuradebajodelterminala
presión.Empujeeldestornillador
mientrastiraelcablehaciaafuera.
O
Acadacontrolse
lehanquitadolas
aletasinteriores
Alcontrolenmediodela
agrupaciónselehanquitado
todaslasaletas
No quitelasaletas
exterioresdeloscontroles
enambosextremosdela
agrupación
Instalación
• Terminalesdetornillo:Use
solamenteconcablesdecobre
sólidosde2,5mm
2
(12AWG)ó
1,5mm
2
(14AWG).NO utilice cable
retorcido ni trenzado.
 Envuelvaelcablealrededordel
tornillodelterminal.Aprietecon
firmezahasta0,55N
m(5pulg-lbs).
b. Conectoresdecable:Prepare
loscables.Alhacerconexiones
decable,sigalaslongitudesparaextremos
peladosylascombinacionesrecomendadas
paralosconectoresproporcionados.
NOTA: Los conectores provistos sonpara
cable de cobre solamente.
Conector de cable:
•
Pele10
mm(3/8
pulg)deaislamientoparacables
de
1,5mm
2
(
14
AWG
)o2,5mm
2
(12AWG).
• Pele11mm(7/16pulg)deaislamientopara
cablesde0,75mm
2
(18AWG)o1,0mm
2
(16AWG).
•
Useparaunirunoodoscablesde
1,5
mm
2
(14
AWG
)o2,5mm
2
(12AWG)con
uncablede0,75mm
2
(18AWG)o1,0mm
2
(16AWG).
 Parainstalacionesenunasolaymúltiples
ubicacionesveaeldiagramas de cableado.
4.Insertetodosloscablesenlacajadeempotrar
ycoloqueelcontrolenlacajausandolos
tornillosdemontajeprovistos.Nopellizquelos
cables.
5.ColoqueeladaptadorylaplacaLutron®Claro®
oSatinColors®.ConsulteDiagrama
de montaje.
a.Instaleeladaptadordelaplacasobreel
frentedel(los)control(es).
b.Ajustelostornillosdemontajedelcontrol
hastaqueeladaptadordeplacaestéaras
conlapared(nolossobreajuste).
c.Presionelaplacasobreeladaptadory
verifiquequeelcontrolestécorrectamente
alineado.
d.Siloscontrolesquedaronmalalineados,
aflojelostornillosdemontajesegún
corresponda.
6.Restablezcalaalimentación.Verifiquequeel
funcionamientolocalseacorrecto.Consulte
Operación del atenuador / ventiladoru
Operación del interruptor.
Reemplazo de lámparas
ADVERTENCIA – Peligro de
choque eléctrico –Paracualquier
otroprocedimientoquenoseael
reemplazohabitualdelaslámparassedebe
desconectarlaalimentacióndesdeelpanel
eléctricoprincipal.Trabajarconlaalimentación
CONECTADApuederesultarenlesiones
personalesgravesolamuerte.
Parasuseguridadduranteelreemplazo
rutinariodelámparas,desconectela
alimentacióndel(los)artefacto(s)tirando
haciaafueraelinterruptorFASS
,ala
posiciónAPAGADO,enelatenuador/
interruptorytambiénentodoslos
atenuadores/interruptoresaccesorios.
Diagrama de montaje
Tornillosde
montajedel
control
Cajade
empotrar
Control
Seincluye:
Conectoresdecable(1o5)
Tornillosdemontaje(2)
Eladaptadorylaplacase
vendenporseparado.
Instalación
3
deunatenuadorenmúltiplesubicaciones
conneutro
4
-F6AN-DVcon-RDo-RD-277(120 /277V~)
Diagrama de cableado 7
Atenuador
Atenuador accesorioAtenuador accesorio
NOTA: Elatenuadordebeserinstalado
delladodelacargadelcircuito
Latón/
Rojo
Negro
Azul
Verde
Tierra
Vivo
Neutro
120/277V~
50/60Hz
Negro
Naranja
Blanco
Negro
Naranja
Blanco
Latón
Negro
Azul
Verde
Tierra
Naranja
Plateado
Latón/
Rojo
Negro
Azul
Verde
Tierra
Instalación
1
enunsololugarsinneutro
-6D,-10D(120V ~)
Diagrama de cableado 1
Latón
Negro
Azul
1
Verde
Tierra
Vivo
Neutro
Carga
Interruptor
120V~
50/60Hz
Instalación
1
enunsololugarsinneutro
-8S-DVconcondensadorparaleloopcional
2
(120-277V~)
Diagrama de cableado 4
Latón
Negro
Azul
1
Verde
Tierra
Vivo
Neutro
Carga
Interruptor
120-277V~
50/60Hz
Condensador
paralelo
2
Opcional
Instalación
1
enunsololugar
conneutro
-F6AN-DV(120/277V~)
Diagrama de cableado 3
Latón
Negro
Azul
1
Verde
Tierra
Vivo
Neutro
Atenuador
120/277V~
50/60Hz
Negro
Naranja
Blanco
Naranja
Plateado
Negro
Naranja
Blanco
DriverLutron®
debalasto/
LED
DriverLutron®
debalasto/
LED
Instalacióndeuninterruptorenmúltiplesubicaciones
3
-6D,-10Dwith-RD(120V~)
Diagrama de cableado 5
Latón
Negro
Azul
Verde
Tierra
Carga
Latón
Negro
Azul
Verde
Tierra
Latón
Negro
Azul
Verde
Tierra
Vivo
Neutro
NOTA: Elattenuadorpuedeser
instaladoencualquierlugardelcircuito.
120V~
50/60Hz
Atenuador
3
/
Atenuador accesorio
Atenuador accesorio/
Atenuador
3
Atenuador accesorio/
Atenuador
3
Instalación
1
enunsololugarconneutro
-6NA,-10ND,-2ANFy-8ANS(120V ~)
Diagrama de cableado 2
120V~
50/60Hz
Latón
Plata
Negro
Azul
1
Verde
Tierra
Vivo
Neutro
Carga
Atenuador / interruptor /
Control de velocidad de ventilador
Operación del interruptor
LED de estado (interruptor
solamente)
Indicaelestadodeluz;brilla
suavementecomoluznocturna
cuandolacargaestáapagada
Interruptor de presión
Presioneparaencenderoapagar
FASS
Frente
Accesible
Servicio
Interruptor
-RD-277o
-RS-277sólo
OR
OFF ON
Guía para la solución de problemas
Síntoma Probable Causa y Acción
Luz/ventiladornose
ENCIENDEN/APAGAN
cuandosepresionael
interruptordepresióndel
atenuador/interruptor/control
develocidaddeventilador
odelatenuador/interruptor
accesorio.
No hay alimentación
•DisyuntorAPAGADOosedisparó.Verifiquesihaycortocircuito.
•InterruptorFASS
enlaposicióndeAPAGADO.CambieelFASS
ala
posicióndeENCENDIDO.Verifiqueelatenuador/interruptor/controlde
velocidaddeventiladorytodoslosatenuadores/interruptoresaccesorios.
ConsulteReemplazo de lámparas.
Cableado
•Cablesencortocircuito.Asegúresedequeelterminalazulnoesté
conectadoatierraoencortocircuitoconotroscables.
•Errorenelcableado.Verifiqueelcableadoparaasegurarsedequecumpla
conlasinstruccionesdeinstalaciónyconlosdiagramasdecableado.
•Por-8S-DV,aumentalacargaparacumplirconlosrequisitosde
cargamínimaouso-8ANS.Instaleuncondensadorenparalelo.Vea
Especificaciones de la carga.
La carga es menor que la carga mínima requerida
•Asegúresedequelacargaconectadacumplaconlosrequerimientosde
cargamínimaparaesecontrol.VealaEspecificaciones de carga.
•Por-8S-DV,aumentalacargaparacumplirconlosrequisitosde
cargamínimaouso-8ANS.Instaleuncondensadorenparalelo.Vea
Especificaciones de la carga.
Las lámparas están quemadas o no están instaladas.
•Reemplaceoinstalelámparas.
Lámparas de diodo
•Siseestánusandolámparasdediodo,reemplácelasporlámparassin
diodos.
Configuración del ventilador
•Asegúresequeelventiladorestáensuvelocidadmáximautilizandolacadena.
Tipo de carga incorrecto del control de velocidad del ventilador
•Asegúresequesolamenteunúnicoventiladordepaletas(motorde
condensadorpermanente)de2Aomenosestáconectadoalcontrol.
•Asegúresequeningunacargadeiluminación(porejemplounjuegodeluz)
estáconectadoalcontrol.
Lacargaparpadeao
interruptorapresiónno
funcionainclusosilacargaes
superiora40W
(-8S-DVsolamente)
Corriente de fuga
•Instaleuncondensadorparalelo.VeaelDiagrama de cableado 4 o 8.
LaluzseENCIENDEyse
APAGAcontinuamenteolas
lucesseENCIENDENcuando
sepresionaelinterruptor,
luegoseAPAGAN
La carga no cumple con los requisitos de carga mínima
•Aumentelacargaparacumplirconlosrequisitosdecargamínimadeese
control.VeaEspecificaciones de la carga.
•Instaleuncondensadorenparaleloconel-8S-DV.VeaelDiagrama de
cableado 4 o 8.
•Por-8S-DV,aumentalacargaparacumplirconlosrequisitosde
cargamínimaouso-8ANS.Instaleuncondensadorenparalelo.Vea
Especificaciones de la carga.
Lacargaparpadea(-8S-DV
solamente)
La carga no cumple los requisitos mínimos de carga
•Aumentelacargaparacumplirconlosrequisitosdecargamínimadeese
control.VeaEspecificaciones de la carga.
•Instaleuncondensadorparalelo.VeaelDiagrama de cableado 4 o 8.
Lasluces/ventiladoresnose
ENCIENDEN/APAGANdesde
unteclado
Programación incorrecta
•ProgrametodoslosdispositivossegúnlaGuía de configuracióndel
sistema.
Fuera del alcance de RF
•Reubiqueparaestaranomásde9m(30pies)deunrepetidordeseñales
deRF.
Cableado
•Cablesencortocircuito.Asegúresedequeelterminalazulnoesté
conectadoatierraoencortocircuitoconotroscables.
•Errorenelcableado.Verifiqueelcableadoparaasegurarsedequecumpla
conlasinstruccionesdeinstalaciónyconlosdiagramasdecableado.
Laplacadeparedestá
caliente
Disipación de calor del control de estado sólido
•Losatenuadores/interruptores/controlesdevelocidaddeventilador
deestadosólidodisipaninternamentecercadel2%delacargatotal
conectada.Esnormalqueatenuadores/interruptores/controlesde
velocidaddeventiladorsesientantibiosaltactoduranteelfuncionamiento.
NOTA: Consulte la guíadeconfiguración del sistema para sugerencias adicionales de solución de problemas.
Para la Guía de configuración del sistema y otras
herramientas visite: www.lutron.com/radiora2
Especificaciones de la carga
Control Tipo de carga Carga mín. Carga máx.
-6D
1
Incand. 50W 600W
BVM
2
50W/VA
450W/
600VA
-6NA
1
Incand./BVE
2
5W 600W
BVM
2
5W/VA
450W/
600VA
-10D
1
Incand. 50W 1000W
BVM
2
50W/VA
800W/
1000VA
-10ND
1
Incand. 10W 1000W
BVM
2
10W/VA
800W/
1000VA
-F6AN-DV
3,4,5
Fluorescentede3
conductores/LED
0,05A 6A
1balasto 60balastos
-2ANF
6
Ventiladordetecho 0,083A 2A
-8ANS
7
Iluminación 10W/VA 8A
Motor 0,08A
1/4HP
5,8A
-8S-DV
8,9
Iluminación 40W/VA 8A
Motor 0,4A
1/10HP
3A
-RD
10
VerelAtenuador
8,3A
-RS
10
VeaInterruptor
-RD-277
11
VerelAtenuador
-RS-277
11
VeaInterruptor
1 Tipo de carga del atenuador: Losmodelos-6D,-10Dy
-10NDestándiseñadosparausarsesolamenteconcargas
incandescentes,magnéticasdebajovoltaje,ohalógenasde
tungstenoinstaladasenformapermanente.
Elmodelo-6NAestádiseñadoparausarsesolamenteconcargas
incandescentes,electrónicosdebajovoltaje,magnéticasdebajo
voltaje,ohalógenasdetungstenoinstaladasenformapermanente.
Noinstaleatenuadoresparacontrolartomasdecorriente
nidispositivosmotorizados.Nocombinartiposdecarga
incandescente,halógena,BVMoBVEenunatenuador.
2 Uso con bajo voltaje:Uselosmodelos-6D,-10Dy-10ND
solamentecontransformadoresmagnéticos(debobinaynúcleo)
debajovoltaje.Nolosusecontransformadoreselectrónicos(de
estadosólido).
Useelmodelo-6NAcontransformadoresatenuableselectrónicos(de
estadosólido)omagnéticos(debobinaynúcleo)debajovoltaje.
Elfuncionamientodeuncircuitodebajovoltajesinlámparasocon
lámparasquenofuncionanpuederesultarenelsobrecalentamiento
deltransformadoryfallasprematuras.Lutronrecomienda
firmementelosiguiente:
a.
Nooperecircuitosdebajovoltajesinlaslámparasencondicio-
nesoperativasensulugar.
b.Reemplacelaslámparasquemadaslomásrápidoposible.
c.Usetransformadoresqueincorporanproteccióntérmicaocon
fusiblesenlosbobinadosprimariosparaprevenirfallasdel
transformadorprovocadasporsobrecorrientes.
3 Tipo de carga del atenuador para luces fluorescentes: El-F6AN-DV
estádiseñadoparaserusadocondriversdeLEDobalastosdeluces
fluorescentesde3conductores,de120V~o277V~,instalados
enformapermanenteycontroladosatravésdelvoltajedelínea.Use
sóloconHi-lume®,Hi-lume®3D,Hi-lume®A-Series,CompactSE
,
Eco-10®,oEcoSystem®(H3D-,FDB-,ECO-,HL3-,EC5-,L3D).NO
usarconotrosbalastosodrivers.Noloinstaleparacontrolartomasde
corrientenielectrodomésticosoperadospormotor.
4 Amplificadores de potencia / Interfaces de carga: -6NA,
-10ND,-F6AN-DV,y-8ANSsepuedenutilizarparacontrolar
amplificadoresdepoder/interfacesdecarga.Paraobteneruna
listadeamplificadoresdepoder/interfacesdecargacompatibles,
consulteLutronP/N369225.
5 Carga Máxima: Lacargamáximaparael-F6AN-DVeslacarga
reducidaoelnúmerodebalastos,loquefueraMENOR.
6 Aplicación de ventilador de techo (-2ANF):
•Useparacontrolarunventiladordetechodepaletas
(decondensadorpermanente).
•Uselacadenadelventiladordetechoparaconfigurarsu
velocidadenelvalormásaltoposible.
•Nouseparacontrolarventiladoresqueusanmotoresdeanillos
dedesfase(comoextractores).
•Nouseparacontrolarventiladoresquetienenuncontrolde
velocidadintegrado(porejemploventiladoresquetienenun
controlremoto),amenosqueelcontrolintegradoseremuevadel
ventiladordetecho.
•Noconecteningúnotrodispositivooperadoamotoroningún
tipodecargadeiluminación.
•Nolouseparacontrolarunacargadeiluminacióndeventilador
(porejemplojuegodeluz).
7 Tipo de carga del interruptor -8ANS: elmodelo-8ANSestá
diseñadoparausarconcargasincandescentes,debajovoltaje
magnético,debajovoltajeelectrónico,ofluorecentesinstaladasen
formapermanenteyconcargasdemotoresdehasta1/4HP(5,8A).
8 Tipo de carga del interruptor -8S-DV: El-8S-DVestádiseñado
parausoconcargaspermanentementeinstaladasde120V ~,
incandescentes,debajovoltajemagnéticooelectrónico,
fluorescentes,omotores;oconcargasde277V~,fluorescentes
odebajovoltajemagnético).
9 Condensador paralelo (incluido): ciertasinstalaciones-8S-DV
puedenrequerirelusodeuncondensadorparalelo.Estoes
especialmentenecesariocontiposdecargasensiblesalacorriente
defuga(porejemplobalastosfluorescentes).Silacargaparpadea,
instaleuncondensadorenparalelo.Paralainstalacióndel
condensadorparaleloveaelDiagrama de cableado 4 o 8.
10 Atenuador / interruptor accesorio de 120 V~ : Los-RDy-RS
estándiseñadosparausarconatenuadores/interruptoresde
120V~.
11 Atenuador / interruptor accesorio de 277V~: Los-RD-277y
-RS-277estándiseñadosparausarconatenuadores/interruptores
de277V~.NOutilizarconunacargamotorizada.
1
Cuandoseusancontroleseninstalacionesconcontroldesdeunsololugar,ajusteelterminalazulsinconectarningúncableal
mismo.NOconecteelterminalazulaningúnotrocableniatierra.
2
ElcondensadorparalelodebeserinstaladodentrodelartefactodecargaoenunacajaJseparada.
3
Instalarsolamenteuna(1)atenuador/ interruptor/controldevelocidaddeventiladorporcircuito.Aunmismo
atenuador/ interruptorpuedenconectarsehasta9atenuadores/interruptores/controlesdevelocidaddeventilador.Ellargototal
delcabledelterminalazulpuedeserhasta76m(250pies).
4
Losatenuadores/interruptores/controlesdevelocidaddeventiladorconcableneutrodebenconectarsedelladodelacarga
deunainstalacióndesdemúltipleslugares.
Instalación
3
concontroldesdevarioslugares,conneutro
4
-6NA,-10ND,-2ANFconRD-RD,y-8ANSconRD-RS(120 V ~)
Diagrama de cableado 6
Latón
Plata
Negro
Azul
Verde
Tierra
Carga
Latón
Negro
Azul
Verde
Tierra
120V~
50/60Hz
Latón
Negro
Azul
Verde
Tierra
Vivo
Neutro
Atenuador accesorio/
interruptor accesorio
Atenuador accesorio/
interruptor accesorio
Atenuador / interruptor /
Control de velocidad de ventilador
NOTA: Elatenuador
debeserinstalado
delladodelacarga
delcircuito
Instalacióndeuninterruptorenmúltiplesubicaciones
3
-8S-DVcon-RSo-RS-277ycondensadorparaleloopcional
2
(120 277V~)
Latón/
Rojo
Negro
Azul
Verde
Tierra
Carga
Latón/
Rojo
Negro
Azul
Verde
Tierra
Latón/
Rojo
Negro
Azul
Verde
Tierra
Vivo
Neutro
NOTA: Elinterruptorpuedeser
instaladoencualquierlugardelcircuito.
120–277V~
50/60Hz
Opcional
Condensador
paralelo
2
Interruptor
3
/
Interruptor accesorio
Interruptor accesorio/
Interruptor
3
Interruptor accesorio/
Interruptor
3
LutronElectronicsCo.,Inc.
7200SuterRoad|Coopersburg,PA18036-1299
P/N044-319Rev.B09/2012
Gire el conector de
cable para afirmarlo
Notas importantes
ADVERTENCIA – Riesgo de quedar
atrapado – Paraevitarelriesgodequedar
atrapado,delesionesgravesolamuerte,
estoscontrolesnodebenusarseparacontrolar
equiposquenoseanvisiblesdesdetodoslos
puntosdecontroloquepuedancausarsituaciones
peligrosas,comoquedaratrapado,siseoperan
accidentalmente.Comoejemplosdeequiposque
nodebenoperarseconestoscontrolespodemos
citar(sinlimitación)portonesmotorizados,
puertasdegaraje,puertasindustriales,hornosde
microondas,almohadillasdecalentamiento,etc.Es
responsabilidaddelinstaladorasegurarqueelequipo
quesecontrolaseavisibledesdetodoslospuntosde
controlyquesóloseconectenequiposadecuados
aestoscontroles.Lafaltadecumplimientopodría
resultarenlesionesgravesolamuerte.
Códigos:Realicelainstalacióndeacuerdocontodos
loscódigoseléctricoslocalesynacionales.
Conexión a tierra:Cuandodentrodelacajade
empotrarnohay“mediosdeconexiónatierra”,
elNationalElectricalCode®2011permitela
instalacióndeuncontrolcomoreemplazo,siempre
ycuando1)seutiliceunaplacafrontalnometálicae
incombustiblecontornillosdefijaciónnometálicoso
2)elcircuitoseencuentreprotegidoporuninterruptor
decircuitosdefallasdeconexiónatierra(GFCI).Al
instalaruncontroldeacuerdoconestosmétodos,
tapeoretirealcableverdeantesdeatornillarel
controlenlacajadeempotrar.
Cables neutros:Losmodelos-6NA,-10ND,
-F6AN-DV,-2ANF,y-8ANSrequierenunaconexión
deneutroenlacajadeempotrarenqueseinstalará
elatenuador/interruptor/controldeventilador.Sino
haydisponibleunaconexióndeneutroenlacajade
empotrar,contacteaunelectricistaautorizadopara
instalarlo.
Condiciones ambientales:Temperaturaambientede
operación:de0ºCa40°C(32°Fa104°F),humedad
de0%a90%,sincondensación.Sóloparausoen
interiores.
Espaciado:Sisemontauncontrolsobreotro,deje
porlomenos114mm(4
½
pulg)deespaciovertical
entreellos.
Placas:LasplacasClaro®ySatinColors®deLutron®
serecomiendanparaunamejorcombinaciónde
coloresyaspectoestético.Nopinteloscontrolesni
lasplacas.
Limpieza:Paralimpiar,paseuntrapohúmedo.NO
useningunasoluciónquímica.
Cajas de empotrar: Parafacilitarlainstalación,
Lutronrecomiendaelusodecajasdeempotrarde
89mm(3
½
pulg)deprofundidad.Varioscontroles
puedeninstalarseenunacajaparadispositivos
múltiples–veaelCuadro de Reducción de la
Potencia Nominal.
Atenuadores / Interruptores remotos:utilice
solamentelosatenuadoresremotos(-RD/-RD-277)e
interruptoresremotos(-RS/-RS-277)conatenuadores
/interruptores/controldevelocidaddeventilador.
Conestosatenuadoresointerruptorespuedenusarse
hasta9-RD/-RD-277o-RS/-RS-277.Losinterruptores
mecánicosde3o4víasnofuncionarán.
Ubicación del dispositivo de RF:losatenuadores/
interruptoresycontrolesdevelocidaddeventilador
deRFdebenubicarseamenosde9m(30pies)de
unrepetidordeseñalesdeRF.Losatenuadores/
interruptoresaccesoriosnoestánsujetosaesta
limitacióndeestarubicadosaciertadistanciade
unrepetidor.
EnsistemasconunrepetidordeseñaldeRF,los
atenuadores/interruptores/controldevelocidadde
ventiladordeRFnopuedensercontroladospor
elsistemahastaquehayansidoprogramadosde
acuerdoconlaGuía de configuracióndelsistema.
* Atenuador:
RRD-6D, -6NA, -10D, -10ND
(120V~50/60Hz)
RRD-F6AN-DV (120/277V~50/60Hz)
* Interruptor:
RRD-
8ANS
(120V~50/60Hz)
RRD-8S-DV (120-277V~50/60Hz)
*
Control de velocidad de ventilador:
RRD-2ANF (120
V~
50/60Hz)
* Atenuadores accesorios:
RD-RD (120
V~
50/60Hz)
RD-RD-277 (277
V~
50/60Hz)
Instrucciones de instalación
Por favor, lea antes de instalar
Español
Maestro® RF estilo designer
* Interruptores accesorios:
RD-RS (120
V~
50/60Hz)
RD-RS-277 (277
V~
50/60Hz)
Atenuador Interruptor
Interruptor
accesorio
Atenuador
accesorio
Controldevelocidad
deventilador
* Condiciones de la prueba de consumo típico de potencia:
Dimmer / Switch / Control de velocidad de ventilador: 0,6 W
(lacargaestáapagada,elmododeluznocturnaestáhabilitado.)
Atenuador / Interruptor accesorio: 0 W(Lacargaestáapagada.)
LEDs de estado (atenuador sólo)
Indicanelniveldeluz;brillan
suavementecomoluznocturna
cuandolacargaestáapagada
Interruptor de presión
Presioneparaencenderoapagar
Balancín de atenuación
Presioneparaaumentarlaintensidadde laluz
oaumentarlavelocidad
Presioneparaatenuar
obajarlavelocidad
FASS
Frente
Accesible
Servicio
Interruptor
Operación del atenuador / ventilador
Atenuador
muestra
 Eninstalacionescondispositivosmúltiples,se
agrupanvarioscontroleshorizontalmenteenuna
cajadeempotrarparadispositivosmúltiples.
 Cuandosecombinancontrolesenunacajade
empotrarserequierereducirlapotencianominal.
 Estonoesnecesarioparaloscontrolesde
velocidaddelventiladoryatenuadores/
interruptoresaccesorios.
Cuadro de reducción de la potencia nominal
Control
Tipo de carga Extremos de la
agrupación
Medio de la
agrupación
-6D
Incand. 500W 400W
BVM
400W/
500VA
300W/
400VA
-6NA
Incand./BVE 500W 400W
BVM
400W/
500VA
300W/
400VA
-10D,
-10ND
Incand. 800W 650W
BVM
600W/
800VA
500W/
650VA
-F6AN-DV*
Fluorescente
de3conduc-
tores/LED
5A 3,5A
50balastos 35
balastos
-2ANF
Ventiladorde
techo
2A 2A
-8ANS
Iluminación 6,5A 5A
Motor
1/4HP
5,8A
1/6HP
4,4A
-8S-DV
Iluminación
8A
(2-dispositivos)
7A
(3-
dispositivos
)
7A
Motor
1/10HP
3A
* Lacargamáximaparael-F6AN-DVeslacargareducida
oelnúmerodebalastos,loquefueraMENOR.
NOTA: Loscontroles-8ANS,-RD-277and
-RS-277tienenaletasquesedebenquitarpara
instalacionesdedispositivosmúltiples.Los
controles-6D,-6NA,-10D,-10ND,-F6AN-DV,
-2ANF,-8S-DV,-RDand-RSnotienenaletasque
debanquitarseparainstalacionesdedispositivos
múltiples.
Adaptador
deplaca
Placa
Tornillosde
montajedel
adaptador
Diagrama de cableado 8
DriverLutron®
debalasto/
LED
DriverLutron®
debalasto/
LED
Directives d’installation
Veuillez lire avant l’installation
Installations à jumelage multiple
 Danslesinstallationsàjumelagemultiple,
plusieurscommandessontregroupées
horizontalementdansunboîtiermuralà
jumelagemultiple.
 Lorsquedescommandessontregroupéesdans
unboîtiermural,ledéclassementestrequis.
Cecines’appliquepasauxcommandedes
devitessedesventilateursetgradateurs/
interrupteursàdistance.
Tableau de déclassement
Commande Type de
charge
Charge
min.
Charge
max.
-6D
Incand. 500W 400W
BTM
400W/
500VA
300W/
400VA
-6NA
Incand./
BTE
500W 400W
BTM
400W/
500VA
300W/
400VA
-10D,-10ND
Incand. 800W 650W
BTM
600W/
800VA
500W/
650VA
-F6AN-DV*
Fluorescent/
DELà3ls
5A 3,5A
50
ballasts
35
ballasts
-2ANF
Ventilateurde
plafond
2A 2A
-8ANS
Éclairage 6,5A 5A
Moteur
1/4HP
5,8A
1/6HP
4,4A
-8S-DV
Éclairage
8A
(duplex)
7A(triple)
7A
Moteur
1/10HP
3A
* Lachargemaximalepourlegradateur-F6AN-DVest
soitlapuissancedechargedéclasséeoulenombrede
ballasts,selonleplusPETITdesdeuxnombres.
REMARQUE : Les commandes -8ANS,-RD-
277and-RS-277ontdesailettesquidoivent
êtreenlevéesavantdefaireuneinstallationà
jumelagemultiple.Les commandes -6D,-6NA,
-10D,-10ND,-F6AN-DV,-2ANF,-8S-DV,-RD
and-RSn’ontpas d’ailetteàenleverpourles
installationsàjumelagemultiple.
Guide de dépannage
Lutron,Claro,SatinColors,Maestro,Hi-lume,Ecosystem,Eco-10,RadioRA,et)sontdesmarquesdecommercedéposéesetRadioRA2,CompactSEetFASSsontdesmarquesdecommercedeLutronElectronicsCo.,Inc.
NECestunemarquedecommercedéposéedeNationalFireProtectionAssociation,Quincy,Massachusetts.
©2012LutronElectronicsCo.,Inc.
Rappel des réglages d’usine des gradateurs/interrupteurs
REMARQUE : Lerappeldugradateur/interrupteur/commandesdevitessedeventilateursàsesréglagesd’usine
leretireradusystèmeeteffaceratoutesaprogrammation.
Étape 1 : Tapertroisfoisdudoigtsurleboutontactiled’uncontrôleetgarderledoigtappuyésurleboutonaprès
latroisièmetape.
Étape 2: Garderleboutonappuyédurantenviron3secondes,jusqu’àcequelesvoyantsdugradateurdébutent
uneséquenced’illuminationdeva-et-vientrapideouquelevoyantDELduinterrupteursemetteà
clignoterrapidement
Étape 3: Relâcherleboutonetrefaireimmédiatementtroistapesrapidessurlebouton.Lesvoyantsdugradateur
débuterontuneséquenced’illuminationdeva-et-vientlente.LevoyantDELduinterrupteurclignotera
lentement.
Lecontrôleestalorsremisàsesréglagesd’usineetdoitêtrereprogrammédanslesystème.
Garantie : voirlagarantieincluseavecleproduitouvisitez:www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
Assistance technique :
É.U./Canada:1.800.523.9466|Mexique:001-888-235-2910
Brésil:+55(11)3257-6745(Lundi-Vendredi8:30to17:30BRT)|Autrespays:+1.610.282.3800
24heuresparjour,7joursparsemaine www.lutron.com
AVERTISSEMENT– Danger
d’électrocution –
Pouréviterleschocs
électriques, Identifieretretirerlefusible
ouverrouillerledisjoncteurenpositionOuvert
(OFF)avantdeprocéder.Effectuerlecâblagesous
tensionpeutentraînerdeslésionscorporelles
graves,voirelamort.
1.Couperl’alimentationauniveaudelaboîteà
fusiblesoududisjoncteur.
2.
Avantd’installerle(s)contrôles,contrôlerla
présencedetoutcourt-circuit.Aprèsavoir
coupél’alimentation,installerlesinterrupteurs
mécaniquesentrelefilsoustensionetla
chargeetrétablirl’alimentation.Sileslumières
nes’allumentpasouqu’undisjoncteur
sedéclenche,vérifieretrendrelecâblage
conformeauschémaappropriéetfaireune
nouvellevérification.N’installerlescontrôles
qu’aprèsavoirvérifiéqu’iln’yapasdecourt-
circuit.Lagarantieseraannuléesiuneunitéde
contrôleestmisesoustensiondansuncircuit
comportantuncourt-circuit.
3.Câblerlescontrôlesselonundesmoyens
décritsci-après:
a. Bornesderaccordement:Couperou
dénuderlesfilsdelaboîtemuraleàla
longueurindiquéeàlajaugededénudageà
l’endosducontrôle.
• Bornesàpression:N’utiliserqu’avec
desconducteursdecuivremassif
decalibre1,5mm
2
(14AWG).
NEPASutiliserdefiltoronnéou
torsadé.
 Insérerleconducteurjusqu’aufond
delaborne.Pourdégagerlefil,
insérerunpetittournevisplatdans
lafentesouslaborne.etappliquer
unepressionenretirantlefil.
OU
Remplacement de tubes/
ampoules
AVERTISSEMENT – Danger
d’électrocution –Pourtoute
autreprocédurequelesimple
remplacementdestubes/ampoules,
l’alimentationdoitêtrecoupéeaupanneau
dedistribution.Effectuertouttravailavec
lesystèmesoustensionpeutentraînerdes
lésionscorporellesgraves,voirelamort.
Pourremplacerlestubes/ampoulessans
danger,couperl’alimentationdesappareils
d’éclairageenplaçantl’interrupteurFASS
dugradateur/interrupteuretdetousles
gradateurs/interrupteursàdistanceen
positionOFF.
Symptôme Cause probable et action suggérée
Lumière/ventilateurne
répondpasàl’actionnement
duboutontactiledu
gradateur/interrupteuroude
latélécommandegradateur/
interrupteur
Sans alimentation
•Disjoncteurouvert(OFF)oudéclenché.Vérifierlaprésenceéventuellede
court-circuit.
•L’interrupteurFASS
estouvert(position«OFF»).Vérifierlegradateur/
interrupteurettouteslestélécommandesgradateur/interrupteur.Voir
Remplacement de tubes/ampoules.
Câblage
•Filscourt-circuités.S’assurerquelabornebleuen’estpasmiseàlaterre
oucourt-circuitéeàd’autresfils.
•Erreurdecâblage.S’assurerquelecâblageestconformeauxdirectives
d’installationetauxschémasdecâblage.
•Pour-8S-DV,augmenterlachargeau-dessusduminimumrequisou
utiliser-8ANS.Installeruncondensateurshunt.VoirSpécifications de
charge.
La charge est en dessous de la charge minimale exigée
•S’assurerquelachargeconnectéeestconformeauxexigences
minimalespourcettecommande.VoirlesSpécifications de charge.
•Pour-8S-DV,augmenterlachargeau-dessusduminimumrequisou
utiliser-8ANS.Installeruncondensateurshunt.VoirSpécifications de
charge.
Ampoules brûlées ou absentes
•Remplacerouinstallerlesampoules.
Ampoules à diodes
•Sidesampoulesàdiodessontutilisées,lesremplacerpardesampoules
d’unautretype.
Réglage de ventilateur
•Assurez-vousqueleventilateurestréglé,parsachaîneàtirette,àsa
vitessemaximale.
Le contrôle de ventilateur n’est pas relié à un type de charge approprié
•Assurez-vousqueseulementunventilateuràpales(moteurbiphaséavec
condensateurreliéenpermanence)decourantnominalde2Aoumoins
estreliéaucontrôle.
•Assurez-vousqu’aucunecharged’éclairage(luminaires)n’estraccordée
aucontrôle.
Lachargescintillentou
boutontactilenefonctionne
pas,mêmesilachargeest
supérieureà40W
(-8S-DVseulement)
Courant de fuite
• Installeruncondensateurshunt.VoirleSchéma de câblage 4 ou 8.
Leslumièress’allumentet
s’éteignentsansarrêtouà
l’actionnementdubouton
tactile,leslumièress’allument
etpuiss’éteignent
La charge est de puissance inférieure au minimum requis
•Augmenterlachargeau-dessusduminimumrequispourcecontrôle.Voir
Spécifications de charge.
•Pourleinterrupteur-8S-DV,ajouteruncondensateurshunt.Voirle
Schéma de câblage 4 ou 8.
•Pour-8S-DV,augmenterlachargeau-dessusduminimumrequisou
utiliser-8ANS.Installeruncondensateurshunt.VoirSpécifications de
charge.
Lachargescintillent
(-8S-DVseulement)
La charge est de puissance inférieure au minimum requis
•Augmenterlachargeau-dessusduminimumrequispourcecontrôle.Voir
Spécifications de charge.
Installeruncondensateurshunt.VoirleSchéma de câblage 4 ou 8.
Lumièresnes’allumentpas
ON/OFFàpartird’unclavier
Programmation inadéquate
•ProgrammerconformémentauGuide de configurationdusystème.
Hors de la portée RF
•Rapprocheràmoinsde9m(30pi)d’unrépétiteurdesignalRF.
Câblage
•Filscourt-circuités.S’assurerquelabornebleuen’estpasmiseàlaterre
oucourt-circuitéeàd’autresfils.
•Erreurdecâblage.S’assurerquelecâblageestconformeauxdirectives
d’installationetauxschémasdecâblage.
Laplaquemuraleestchaude Dissipation de la commande à semi-conducteurs
•Lesgradateurs/interrupteurs/commandedevitessedeventilateurà
semi-conducteursdissipentàl’intérieurenviron2%delachargetotale
raccordée.Ilestnormalqu’ilssoientchaudsautoucherlorsqu’ilssont
enservice.
REMARQUE : Pour des suggestions additionnelles de dépistage de défauts, se référer au guidedeconfiguration.
• Bornesàvis:N’utiliserqu’avec
desconducteursdecuivremassif
decalibre2,5mm
2
(12AWG)ou
1,5mm
2
(14AWG). NE PAS utiliser
de fil multibrins ou toronné. Enrouler
leconducteursouslatêtedelavis
delaborne.Serreraucouplede
0,55N
m(5lb-po).
b. Capuchonsdeconnexion:
Préparationdesfils.Pourles
connexionsaveccapuchon,seconformer
auxlongueursdedénudagerecommandées
pourlescombinaisonsdelsutilisésavec
lescapuchonsfournis.
REMARQUE : Les capuchons de connexion
fournis s’utilisent avecdes fils de cuivre
seulement.
Capuchon de connexion
•
Pourlesfilsdecalibre
1,5mm
2
(
14AWG
)ou
2,5mm
2
(12AWG),enleverl’isolantsur
10mm(3/8po).
• Pourlesfilsdecalibre0,75mm
2
(18AWG)ou
1,0mm
2
(16AWG),enleverl’isolantsur
11mm(7/16po).
•
Utiliserpourraccorderunoudeuxfils1,5mm
2
(14AWG
)ou2,5mm
2
(12AWG)avecunfil
decalibre0,75mm
2
(18AWG)ou1,0mm
2
(16AWG)
 Pourinstallationd’uneuniqueetàmultiples
Voirschémas de câblage.
4.Repoussertouslesfilsdansleboîtiermuralet
visserlégèrementlecontrôleauboîtieràl’aide
desvisdemontagefournies.Nepascoincer
lesfils.
5.Attacherl’adaptateurdelaplaquemuraleet
laplaquemuraleClaro®ouSatinColors®de
Lutron®.VoirleSchéma d’assemblage.
a.Installerl’adaptateurdelaplaquemuralesur
ledevantdu/descontrôle(s).
b.Serrerlesvisdemontageducontrôle
jusqu’àcequel’adaptateurduboîtiermural
soitàégalitédumur(nepastropserrer).
c.Enclencherlaplaquemuralesurl’adaptateur
ets’assurerquelecontrôleestbienaligné.
d.Silescontrôlessontmalalignés,desserrer
lesvisdemontageenconséquence.
6.Rétablirl’alimentation.Vérifiersile
fonctionnementlocalestcorrect.
VoirlafeuilledeFonctionnement du
gradateur / commande de vitesse de
ventilateurouFonctionnement du
interrupteur.
Visser fermement
le capuchon de
connexion
Installation
Lesailettesentretous
lescontrôlesadjacents
sontenlevées
Lecontrôledumilieu
del’unitéasesailettes
latéralesenlevéesdes
deuxcôtés
Ne pas retirerles
ailettesextérieures
auxextrémitésde
l’alignementde
contrôles
multiples
Schéma d’assemblage
Visde
montage
des
contrôles
Boîtiermural
Commande
Inclus:
Capuchonsdeconnexion(1ou5)
Visdemontage(2)
Adaptateurdeplaque
muraleetplaquemurale
vendusséparément.
Adaptateur
deplaque
murale
Plaque
murale
Visde
montagede
l’adaptateur
Installation
1
d’unseulsansneutre
-8S-DVaveccondensateurshuntenoption
2
(120-277V~)
Schéma de câblage 4
Laiton
Noir
Bleu
1
Vert
Miseà
laterre
Sous
tension
Neutre
Charge
Interrupteur
120-277V~
50/60Hz
Condensateur
shunt
2
Optionnel
Installation
1
d’unseulgradateur
avecneutre
-F6AN-DV(120/277V~)
Schéma de câblage 3
Laiton
Noir
Bleu
1
Vert
Miseà
laterre
Sous
tension
Neutre
Gradateur
120/277V~
50/60Hz
Noir
Orange
Blanc
Orange
Argenté
Noir
Orange
Blanc
Ballast/pilotede
lampeàdiodes
Lutron
®
Ballast/pilotede
lampeàdiodes
Lutron
®
Installation
1
d’unseulsansneutre
Interrupteur-
6D,-10D(120V ~)
Schéma de câblage 1
Laiton
Noir
Bleu
1
Vert
Miseà
laterre
Sous
tension
Neutre
Charge
Interrupteur
120V~
50/60Hz
Installation
1
d’unseul
avecneutre
-6NA,-10ND,-2ANFet-8ANS(120V ~)
Schéma de câblage 2
120V~
50/60Hz
Laiton
Argent
Noir
Bleu
1
Vert
Miseà
laterre
Sous
tension
Neutre
Charge
Gradateur / interrupteur /
commande de vitesse de ventilateur
Installation
3
degradateursàemplacementsmultiplesavecneutre
4
Gradateur-F6AN-DVavecgradateuràdistance-RDou-RD-277
(120/277V~)
Gradateur
Gradateur à distanceGradateur à distance
REMARQUE : Legradateurprincipal
doitêtreraccordéàlacharge.
Laiton/
Rouge
Laiton/
Rouge
Noir
Bleu
Vert
Miseà
laterre
Sous
tension
Neutre
120/277V~
50/60Hz
Noir
Orange
Blanc
Noir
Orange
Blanc
Laiton
Noir
Bleu
Vert
Miseà
laterre
Orange
Argenté
Noir
Bleu
Vert
Miseà
laterre
Installation
3
àemplacementsmultiplessansneutre
Gradateur-6D,-10Dwith-RD(120V ~ )
Laiton
Noir
Bleu
Vert
Miseà
laterre
Charge
Gradateur
3
/
gradateur à distance
Laiton
Noir
Bleu
Vert
Miseà
laterre
Gradateur à
distance / gradateur
3
Laiton
Noir
Bleu
Vert
Miseà
laterre
Sous
tension
Neutre
Gradateur à
distance / gradateur
3
REMARQUE : Legradateurpeut
êtreinstalléàn’importequel
emplacementdanslecircuit.
120V~
50/60Hz
Pour le Guide de configuration du système et outils
requis, consulter le site www.lutron.com/radiora2
Spécifications de charge
Commande Type de
charge
Charge
min.
Charge
max.
-6D
1
Inc. 50W 600W
BTM
2
50W/VA
450W/
600VA
-6NA
1
Inc./BTE
2
5W 600W
BTM
2
5W/VA
450W/
600VA
-10D
1
Inc. 50W 1000W
BTM
2
50W/VA
800W/
1000VA
-10ND
1
Inc. 10W 1000W
BTM
2
10W/VA
800W/
1000VA
-F6AN-DV
3,4,5
Fluorescent/
DELàtrois
(3)ls
0,05A 6A
1ballast 60ballasts
-2ANF
6
Ventilateurde
plafond
0,083A 2A
-8ANS
7
Éclairage 10W/VA 8A
Moteur 0,08A
1/4HP
5,8A
-8S-DV
8,9
Éclairage 40W/VA 8A
Moteur 0,4A
1/10HP
3A
-RD
10
Voirgradateur
8,3A
-RS
10
Voirinterrupteur
-RD-277
11
Voirgradateur
-RS-277
11
Voirinterrupteur
1 Type de charge pour gradateur : -6D,-10Det-10NDsont
conçusseulementpourdeschargesinstalléesenpermanence,
incandescentes,magnétiquesàbassetensionoutungstènehalogène.
-6NAestconçueseulementpourdeschargesinstalléesen
permanence,incandescentes,électroniquesàbassetension,
magnétiquesàbassetensionoutungstènehalogène.
Nepasinstallerdegradateurspourlacommandedeprises
standardsoud’appareilsmotorisés.Nemélangezpaslestypesde
chargeincandescente,halogène,BTMouBTEsurungradateur.
2 Applications à basse tension :Utilisezlesgradateurs-6D,-10Det
-10NDuniquementsurdeschargesàtransformateurbassetension
ferro-magnétique.Nepasutilisersuruntransformateurélectronique
(àsemi-conducteur).Utiliserlegradateur-6NAsurdeschargesà
contrôlablestransformateurbassetensionélectronique(àsemi-
conducteur)ouferro-magnétique.
Lefonctionnementd’uncircuitd’éclairageàbassetensionayant
desampouleshorsd’usageounoninstalléespeutcauseune
surchauffedutransformateuretunedéfaillanceprématurée.Lutronfait
lesrecommandationssuivantes:
a.Nepasutiliserlescircuitsàbassetensionquinesontpasdotés
delampesenétatdefonctionnement.
b.Remplacerdèsquepossiblelesampouleshorsd’usage.
c.Utiliserlestransformateursavecprotectionthermiqueou
enroulementsprimairesàfusibleafind’empêcherune
défaillancecauséeparsurintensité.
3 Type de charge pour gradateur fluorescent: Legradateur
-F6AN-DVestconçupourutilisationavecballastsdefluorescents
oupilotesdelampesàDELraccordésenpermanencesurun
circuit120V~ou277V ~à3fils.Utiliserseulementlesappareils
Hi-lume®,Hi-lume®3D,Hi-lume®A-Series,CompactSE
,Eco-10®,
orEcoSystem®(H3D-,FDB-,ECO-,HL3-,EC5-,L3D).NePASutiliser
desballastsoupilotesdifférentsaveccesproduits.Nepasinstaller
pourlecontrôledeprisesdecourantoud’appareilsmotorisés.
4 Amplificateur de puissance / charge d’interfaces: -6NA,-10ND,
-F6AN-DV,et-8ANSnepeutêtreutilisépourcontrôleramplificateur
depuissance/ charged’interfaces.Pourconnaîtrelestypesde
amplificateurdepuissance/ charged’interfacescompatiblesvoir
LutronP/N369225.
5 Charge maximale: Lachargemaximalepourlegradateur-F6AN-DV
estsoitlapuissancedechargedéclasséesoitlenombredeballasts,
selonleplusPETITdecesdeuxnombres.
6 Application de ventilateur de plafond (-2ANF) :
•S’utilisepourcommanderunseulventilateurdeplafond(moteur
biphaséàcondensateurpermanent).
•Àl’aidedelachaîneàtirette,réglezlavitesseduventilateuràson
maximum*.
 •Nepasutiliserpourcommanderlesventilateursutilisantunmoteurà
pôleécran(p.ex.lesventilateursdedécharged’airdesalledebain).
•Nepasutiliserpourcommanderunventilateurquiaunecommande
devitesseintégrée(ouquiestcommandéàdistance)àmoinsquela
commandedevitessesoitretiréeduventilateurplafonnier*.
•Nepasraccorderàtoutautretyped’appareilmotoriséouautretype
decharged’éclairage.
•Nepasutiliserpourcommanderunecharged’éclairagede
plafonnier(luminaire).
7 Type de charge pour interrupteur -8ANS: Lacommande-8ANSest
conçuepouruneutilisationsurdeschargesinstalléesenpermanence,
incandescentes,magnétiquesàbassetension,electroniquesàbasse
tensionoufluorescentesetchargesmotoriséesjusqu’à1/4HP(5,8A)
fixes.
8 Type de charge pour interrupteur -8S-DV: Leinterrupteur-8S-DV
estconçupourutilisationavecdeschargesmotorisées,fluorescentes,
incandescentes,àtransformateurB.T.magnétiqueouélectronique
raccordéesenpermanencesurunealimentationà120V ~ouavec
chargesfluorescentesouàtransformateurB.T.magnétiqueraccordées
enpermanencesuruncircuitalimentéà277V ~.
9 Condensateur shunt (inclus): Certainesapplicationsduinterrupteur
-8S-DVpeuventnécessiterl’installationd’uncondensateurshunt.Ceci
estprincipalementrequispourlestypesdechargessensiblesaux
courantsdefuite(parex.ballastsfluorescentes).Silachargescintille,
installeruncondensateurshunt.Pourl’installationd’uncondensateur
shunt,voirleSchéma de câblage 4 ou 8.
10 Gradateur/interrupteur à distance à 120V~:
Lesgradateurs/interrupteursàdistance-RDet-RSsontconçuspour
utilisationavecdesgradateurs/interrupteursà120V~.
11 Gradateur/interrupteur à distance à 277V~: Les
gradateurs/interrupteursàdistance–RD-277et–RS-277sontconçus
pourutilisationavecdesgradateurs/interrupteursà277V ~.NePAS
utiliseravecunechargemotorisée.
1
Pourlesinstallationsàunseulemplacementdecommande,serrerlabornebleuesansyrelierdefil.NEconnecteraucundes
fils,oufildemiseàlaterreàlabornebleue.
2
Lecondensateurshuntdoitêtreinstalléàl’intérieurduboîtierdel’appareild’éclairageoudansunboîtierdejonctionséparé.
3
Installerun(1)seulementgradateur/interrupteur/commandesdevitessedeventilateursparcircuit.Uncircuitdegradateur/
interrupteur/commandedevitessedeventilateurpeutcomprendrejusqu’à9contrôlesgradateur/interrupteur/commandede
vitessedeventilateuràdistance.Lalongueurpermisedufilbleuestde76m(250pi).
4
Lesgradateurs/interrupteurs/commandesdevitessedeventilateursavecfilneutredoiventêtreconnectésducôtécharge
d’uneinstallationàemplacementmultiple.
Fonctionnement du
interrupteur
Voyant d’état (-8S-DV seulement)
Indiquel’étatdel’appareil
d’éclairageetémetunelueur
discrètedeveilleuselorsquela
chargeestcoupée
Bouton touche
Toucherpourallumer/éteindre
FASS
Interrupteur
deServiceà
AccèsFrontal
-RD-277ou
-RS-277seulement
OR
OFF ON
Installation
3
àemplacementsmultiplesavecneutre
4
-6NA,-10ND,-2ANFavecRD-RD,-8ANSavecRD-RS(120V ~ )
Schéma de câblage 6
Schéma de câblage 5
Laiton
Argent
Noir
Bleu
Vert
Miseàla
terre
Charge
Laiton
Noir
Bleu
Vert
Miseàla
terre
120V~
50/60Hz
Laiton
Noir
Bleu
Vert
Miseàla
terre
Sous
tension
Neutre
Gradateur à distance ou
interrupteur à distance
Gradateur à distance ou
interrupteur à distance
Gradateur / interrupteur /
commande de vitesse de ventilateur
REMARQUE : Legradateur/interrupteur
principaldoitêtreraccordéàlacharge.
Installation
3
àemplacementsmultiplessansneutre
Interrupteur-8S-DVavecinterrupteuràdistance-RSou-RS-277etcondensateur
shuntenoption
2
(120-277V~ )
Schéma de câblage 8
Schéma de câblage 7
Noir
Bleu
Vert
Miseà
laterre
Charge
Interrupteur
3
/ interrupteur
à distance
Noir
Bleu
Vert
Miseà
laterre
Interrupteur à
distance / interrupteur
3
Laiton/
Rouge
Laiton/
Rouge
Laiton/
Rouge
Noir
Bleu
Vert
Miseà
laterre
Sous
tension
Neutre
Interrupteur à
distance / interrupteur
3
REMARQUE : Leinterrupteurpeutêtreinstallé
àn’importequelemplacementdanslecircuit.
120-277V~
50/60Hz
Optionnel
Condensateur
shunt
2
LutronElectronicsCo.,Inc.
7200SuterRoad|Coopersburg,PA18036-1299
P/N044-319Rev.B09/2012
Français
Notes importantes
AVERTISSEMENT – Danger d’enfermement
Pouréviterlesdangersd'enfermement,de
gravesblessuresouledécèsdepersonne,
cescommandesnedoiventpasêtreutiliséespour
contrôlerdeséquipementsquinesontpasvisibles
àpartirdetouslesemplacementsdecommandeou
pouvantcréerdessituationsdangereusesoudes
piègessiellessontactionnéesaccidentellement.Les
équipementsquinedoiventpasêtrecontrôlésparces
commandescomprennent(maissanss’ylimiter):les
barrièresmotorisées,lesportesdegarage,lesportes
industrielles,lesfoursàmicro-onde,lescoussins
chauffantsetc.Ilestdelaresponsabilitédel’installateur
des’assurerquel’équipementcommandéestvisible
àpartirdetouslesemplacementsdecommandeet
queseulsdeséquipementsappropriéssontconnectés
àcescontrôles.Lenonrespectdecetterèglepeut
causerdesblessuresgravesoufatales.
Codes :Installerconformémentàtouslescodes
électriqueslocauxetnationaux.
Mise à la terre:Danslescasoùleboîtiermuralne
possèdeaucun“dispositifderaccordementdefils
deterre”,lecode“NationalElectricalCode®”(NEC®)
2011américainpermetl’installationdecontrôles
deremplacementsi:1)uneplaquefrontalenon
métalliqueetininflammableestutiliséeetfixéepar
desvisnonmétalliquesou2)lecircuitestprotégé
parundisjoncteurdefuitedeterre(GFCI).Lorsde
l’installationd’uncontrôleurselonl’unedesces
méthodes,placezuncapuchonsurlefilvert(ouretirez-
le)avantdemonterlecontrôleurdansleboîtiermural.
Connexion au fil de neutre:Lesgradateurs-6NA,
-10ND,-F6AN-DV,-2ANF,et-8ANSrequièrent
uneconnexionaufilneutreduboîtemuraleoùles
gradateur/interrupteur/commandedeventilateur
doiventêtreinstallés.Siunfilneutren’estpasprésent
dansleboîtemurale,contacterunélectriciencertifié
pourmodifierl’installation.
Environnement :Températureambiantede
fonctionnement:0ºCà40°C(32°Fà104°F)0à
90%d’humiditésanscondensation.Usageà
l’intérieurseulement.
Espacement :Pourinstallerunecommande
au-dessusd’uneautre,laisserunespacevertical
d’aumoins114mm(4
½
po)entreelles.
Plaques murales :LesplaquesmuralesClaro®
etSatinColors®deLutron®sontrecommandées
pourobtenirlemeilleurassortimentdecouleurs
etuneapparenceesthétique.Nepaspeindreles
commandesnilesplaquesmurales.
Nettoyage :Pournettoyer,essuyeràl’aided’un
lingepropreethumide.NE PASutiliserdenettoyants
chimiques.
Plaques murales : Lutronrecommandelesboîtes
muralesde89mm(3
½
po)deprofondeurpour
faciliterl’installation.Plusieurscommandespeuvent
êtreregroupéesdansuneboîteàassemblage
multiple.VoirTableau de déclassement.
Gradateurs/interrupteurs à distance:Utiliser
uniquementlesgradateursàdistance(-RD/
-RD-277)etinterrupteursàdistance(-RS/-RS-277)
aveclesinterrupteurs/gradateurs. Untotalde9
-RD/-RD-277ou-RS/-RS-277peuventêtreutilisés
aveclesgradateursouinterrupteurs.Lesinterrupteurs
mécaniquesàtroisouquatrevoiesnesontpas
compatiblesaveclesystème.
Emplacement des dispositifs RF :Les
gradateurs/interrupteursetcommandesdevitesse
deventilateursRFdoiventêtreplacésàmoinsde9m
(30pi)d’unrépétiteurdesignalRF.Lesgradateurs/
interrupteursàdistancenedoiventpasêtre
obligatoirementàunedistancespécifique
d’unrépétiteur.
PourlessystèmesavecunrépétiteurdesignalRF,
lesgradateurs/interrupteurs/commandesdevitesse
deventilateursRFnepeuventpasêtrecommandé
parlesystèmeavantd’êtreprogrammésdansun
systèmeconformémentauGuide de configuration
desystèmes.
* Conditions typiques d’essai de consommation d’énergie:
Gradateur / Comutateur / Commande de vitesse de ventilateur : 0,6 W
(Lachargeestcoupéeetlemodeéclairagenocturneestactivé.)
Gradateur / Interrupteur à distance : 0 W(Lachargeestcoupée.)
* Gradateur :
RRD-6D, -6NA, -10D, -10ND
(120V~50/60Hz)
RRD-F6AN-DV (120/277V~50/60Hz)
* Interrupteur :
RRD-
8ANS
(120V~50/60Hz)
RRD-8S-DV (120-277V~50/60Hz)
* Interrupteurs à distance:
RD-RS (120
V~
50/60Hz)
RD-RS-277 (277
V~
50/60Hz)
*
Commande de vitesse de ventilateur
:
RRD-2ANF (120
V~
50/60Hz)
* Gradateurs à distance :
RD-RD (120
V~
50/60Hz)
RD-RD-277 (277
V~
50/60Hz)
Gradateurs style décorateur Maestro® RF
Voyants d’état (-F6AN-DV seulement)
Indiqueleniveaud’éclairageetémet
unelueurdiscrètedeveilleuselorsque
lachargeestcoupée
Bouton touche
Toucherpourallumer/éteindre
Bouton d’actionnement à bascule du gradateur
Appuyerpouraugmenterl’intensitéd’éclairage
ouaugmenterlavitesse
Appuyerpourdiminuerl’intensitéd’éclairage
oudiminuerlavitesse
FASS
Interrupteurde
ServiceàAccès
Frontal
Fonctionnement du gradateur /
commande de vitesse de ventilateur
Gradateur
montré
Gradateur Interrupteur
Interrupteur
àdistance
Gradateur
àdistance
Commandede
vitessedeventilateur
Ballast/pilotede
lampeàdiodes
Lutron
®
Ballast/pilotede
lampeàdiodes
Lutron
®
Instruções de instalação
Por favor, leia antes de instalar
Instalações múltiplas
 Eminstalaçõesmultigrupos,várioscontrolessão
reunidoshorizontalmenteemumamesmacaixade
embutir.
 Aocombinarcontrolesemumacaixadeembutir,
éprecisoreduziracarga.Issonãoénecessário
paracontrolesdevelocidadedeventiladore
dimmers/interruptoresremotos.
Tabela de redução de carga
Controle Tipo de
carga
Extremo
final do
agrupa-
mento
Meio do
agrupa-
mento
-6D
Incand. 500W 400W
BTM
400W/
500VA
300W/
400VA
-6NA
Incand./
BTE
500W 400W
BTM
400W/
500VA
300W/
400VA
-10D,
-10ND
Incand. 800W 650W
BTM
600W/
800VA
500W/
650VA
-F6AN-DV*
Fluores-
cente/LED
de3os.
5A 3,5A
50
balastros
35
balastros
-2ANF
Ventilador
deteto
2A 2A
-8ANS
Iluminação 6,5A 5A
Motor
1/4HP
5,8A
1/6HP
4,4A
-8S-DV
Iluminação
8A
(2-grupos)
7A
(3-grupos)
7A
Motor
1/10HP
3A
* Acagamáximaparao-F6AN-DVéacargareduzidaouo
númerodebalastros,oqueforMENOR.
NOTA: -8ANS,-RD-277and-RS-277possuem
aletasqueprecisamserremovidasparainstalações
multigrupos.-6D,-6NA,-10D,-10ND,-F6AN-DV,
-2ANF,-8S-DV,-RDand-RSnão possuemabas
queprecisamserremovidas.
Notas importantes
AVISO – Perigo de imobilização – Para
evitaroriscodeimobilização,ferimentos
gravesoumorte,estescontrolesnãodevem
serusadosparacontrolarequipamentosquenão
estãovisíveisapartirdetodososlocaisdecontrole
ouquepodemcriarsituaçõesperigosas,como
imobilização,casosejaoperadoacidentalmente.
Exemplosdeequipamentosquenãodevem
seroperadosporestescontrolesincluem(mas
nãoselimitama)portõesmotorizados,portões
degaragem,portõesindustriais,fornosde
microondas,etc.Éderesponsabilidadedequem
instalagarantirqueoequipamentoqueestásendo
controladoestejavisíveldecadalocaldecontrole
equesomenteequipamentosadequadossejam
conectadosaestescontroles.Procederdemaneira
contráriapoderácausarmorteouferimentosgraves.
Códigos:Instaledeacordocomoscódigos
elétricoslocaisenacionais.
Aterramento:Senãohouveruma“formade
aterramento”dentrodacaixadeembutir,oCódigo
NacionaldeEletricidadede2011(2011National
ElectricalCode®-NEC®)permitequeumcontrole
sejainstaladocomoumsubstituto,se1)um
espelhonãometálicoenãocombustívelforusado
comparafusosnãometálicosou2)ocircuitofor
protegidoporuminterruptordiferencialporfalha
noaterramento(GFCI).Aoinstalarumcontrolede
acordocomessesmétodos,tampeouremovao
fioverdeantesdeparafusarocontrolenacaixade
embutir.
Neutro:Osmodelos-6NA,-10ND,-F6AN-DV,
-2ANF,e-8ANSexigemumcondutorneutronacaixa
deembutir,ondedevemserinstaladosodimmer/
interruptor/controlesdeventilador.Senãohouver
umcondutorneutronacaixadeembutir,procureum
eletricistaautorizadoparainstalá-lo.
Ambiente:Temperaturaambientedetrabalho:0°C
a40°C(32°Fto104°F),0%a90%deumidade,
semcondensação.Usosomenteinterior.
Espaçamento:Seforinstalarumcontrolesobreo
outro,mantenhaumespaçoverticalentreelesde
pelomenos114mm(4
½
in).
Espelhos:osmodelosLutron®Claro®eSatin
Colors®sãorecomendadospelavariedadedecores
epelodesign.Nãopinteoscontrolesouespelhos.
Limpeza:Paralimpar,passeumpanolimpoúmido.
NÃOusequalquersoluçãoquímicadelimpeza.
Caixa de embutir: ALutronrecomendaousode
caixascom
89
mm(3
½
in)deprofundidadepara
facilitarainstalação.Épossívelinstalarvários
controlesemumamesmacaixadeinstalação
embutida.ConsulteoTabela de redução de carga.
Dimmers / interruptores remotos:Usesomente
dimmersremotos(-RD/-RD-277)einterruptores
remotos(-RS/-RS-277)comdimmers/interruptores.
Podemserusadosaté9-RD/-RD-277or
-RS/-RS-277comdimmersouinterruptores.
Interruptoresmecânicosde3ou4viasnão
funcionarão.
Localização dos dispositivos de RF:Os
dimmers/interruptoresecontrolesdevelocidade
deventiladordeRFdevemestaraumadistância
máximade9m(30pés)deumrepetidordesinal
deRF.Osinterruptores/dimmersremotosnão
precisamestardentrodelimitesespecíficosem
relaçãoaumrepetidor.
ParasistemascomrepetidordesinaldeRF,os
dimmers/interruptores/controlesdevelocidadede
ventiladordeRFnãopodemsercontroladospelo
sistemaenquantonãoestiveremprogramadosde
acordocomoGuia de configuraçãodosistema.
Lutron,Claro,SatinColors,Maestro,Hi-lume,Ecosystem,Eco-10,RadioRA,e)sãomarcasregistradaseRadioRA2,CompactSEeFASSsãomarcasregistradassdaLutronElectronicsCo.,Inc.
NECémarcaregistradadaNationalFireProtectionAssociation,Quincy,Massachusetts.
©2012LutronBrasilLtda.
Restauração dos dimmers/interruptores para a configuração de fábrica
NOTA: Arestauraçãodeumdimmer/interruptor/controldevelocidadedeventiladoreparaaconfiguraçãodefábricao
removerádosistemaeapagarátodaaprogramação
Passo 1: Toquetrêsvezesnachaveseletoradeumcontrole.NÃOsolteapósoterceirotoque.
Passo 2: Mantenhaachaveseletorapressionadaapósoterceirotoque(poraproximadamente3segundos)atéqueos
LEDsnodimmercomecemapiscaremsequênciaparacimaeparabaixorapidamenteouoLEDnointerruptor
pisquerapidamente.
Passo 3: Solteachaveseletorae,imediatamente,pressione-atrêsvezesnovamente.OsLEDsnodimmersedeslocarão
paracimaeparabaixolentamente.OLEDnointerruptorpiscarálentamente.
Ocontroleagoraretornouàconfiguraçãodefábricaeprecisaserprogramadoparaumsistema.
Garantia:Consulteagarantiaqueacompanhaoprodutoouvisite:www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
Assistência técnica:
Brasil:+55(11)3257-6745(Segunda-feira–Sexta-feira8:30to17:30BRT)
E.U.A.
/
Canadá:1.800.523.9466|México:+1.888.235.2910|Outrospaíses:+1.610.282.3800
24horaspordia,7diasporsemana www.lutron.com
ATENÇÃO – Risco de choques –
Paraevitaroriscodechoques
elétricos, localizeeremovaofusívelou
traveodisjuntornaposiçãoOFF(desligado)
antesdeprosseguir.Fazerinstalaçãocoma
chavegeralligadapoderesultaremlesões
gravesoufatais.
1. DESLIGUEaalimentaçãonacaixadefusível
ounodisjuntor.
2.
Verifiqueainstalaçãoquantoacurtos-circuitos
antesdeinstalaro(s)controle(s).Coma
alimentaçãoDELSIGADA,instaleinterruptores
mecânicospadrãoentrequenteeacarga.
Restabeleçaaalimentação.Seaslâmpadas
eventalidoresnãofuncionarouodisjuntorfor
desarmado,verifiqueafiação.Corrijaafiaçãoe
verifiquenovamente.Instaleoscontrolessomente
quandonãohouvercurtos-circuitos.Agarantia
éinvalidadaseocontrolefoiacionado(ON)
havendoumcurto-circuito.
3.Conecteoscabosdeacordocomumadas
opçõesabaixo:
a. Terminais:Apareouretireoisolamentodos
fiosdacaixadeembutirnocomprimento
indicadopelomedidordecorte,naparte
posteriordocontrole.
• Terminaisapressão:Useapenas
comofio1,5mm
2
(14AWG)
de cobre sólido.NÃOusecabos
trançadosoutorcidos.Insiraos
caboscompletamente.Parasoltar
umcabo,insiraumachavedefenda
pequenanaranhuraabaixodo
terminalapressão.Pressioneachave
defendaenquantopuxaocabo
parafora.
OU
Substituição de lâmpada
AVISO – Perigo de choque –No
casodequalquerprocedimento
quenãosejaatrocarotineirade
lâmpadas,opainelelétricoprincipaldeverá
estardesconectadodaredeelétrica.
Trabalharcomaredeligadapoderesultarem
lesõesgravesoufatais.
Parasuasegurançanocasodetroca
rotineiradelâmpadas,desliguea(s)
luminária(s)movendoointerruptorFASS
dodimmer/interruptoredetodosos
interruptores/dimmersremotosparaa
posiçãoOFF(desligado).
• Terminaisparafusados:Useapenas
comofio2,5mm
2
(12AWG)ou
1,5mm
2
(14AWG)de cobre sólido.
NÃOusecabostrançadosou
torcidos.Enroleocaboemvoltado
terminalparafusado.Apertebem
com0,55N
m(5pol-lb).
b. Conectoresdecabos:
Prepareoscabos.Aofazer
conexõesdecabos,sigao
comprimentorecomendadodedesencape
eascombinaçõesparaosconectoresde
cabofornecidos
NOTA: Os conectores de cabo fornecidos são
adequados somentepara cabos de cobre.
Conector de cabo:
•
Remova10mm(3/8pol)deisolantedofio
1,5mm
2
(
14AWG
)oudofio
2,5mm
2
(12AWG).
• Remova11mm(7/16pol)deisolantedo
fio0,75mm
2
(18AWG)oudofio1,0mm
2
(16AWG).
•
Useparaunirumoudoiscabos1,5mm
2
(14
AWG
)ou2,5mm
2
(12AWG)comumcabo
0,75mm
2
(18AWG)ou
1,0mm
2
(16AWG).
 Instalaçãoemumsólocalouvárioslocais
consulteosesquema de ligações.
4.Coloqueoscabosdevoltanacaixade
embutireparafuse,semapertar,ocontrolena
caixausandoosparafusosfornecidos.Não
amasseoscabos.
5.Prendaoadaptadordeespelhoeoespelho
Claro®ouSatinColors®daLutron®.Consulte
oDiagrama de montagem.
a.Instaleoadaptadordoespelhonafrente
do(s)controle(s).
 b.Aperteosparafusosdemontagemdo
controleatéqueadaptadordoespelho
fiquerenteàparede(nãoapertedemais).
c.Encaixeoespelhonoadaptadoreverifique
seocontroleestáalinhadocorretamente.
d.Seoscontrolesestiveremdesalinhados,
afrouxeosparafusosdemontagem
apropriadamente
6.Restabeleçaaalimentação.Verifiquese
aoperaçãolocalestácorreta.Consulte
aOperação do dimmer / controle de
velocidade de ventiladorouOperação
do interruptor.
Gire com firmeza
o conector de
fiação
Instalação
Guia para resolução de problemas
Sintoma Causa provável e ação
Asluzouventiladornão
ACENDEM/APAGAM
quandoachaveseletorano
dimmer/interruptor/controle
develocidadedeventilador
oudimmer/interruptorremoto
épressionada
Não há alimentação.
•DisjuntorDESLIGADOouaberto.Verifiquesehácurtos-circuitos.
• FASS
estánaposiçãoOFF.MudeFASS
paraaposiçãoON.Verifiqueo
dimmer/interruptor/controledevelocidadedeventilador,bemcomotodos
osdimmers/interruptoresremotosConsulteSubstituição da lâmpada.
Fiação
•Cabosemcurto.Verifiqueseoterminalazulnãoestáconectadoaoterra
ouemcurtocomalgumoutrocabo.
•Erronafiação.Verifiqueseafiaçãoestádeacordocomasinstruçõesde
instalaçãoeosdiagramasdeconexão.
•Para-8S-DV,Verifiqueseascargasconectadasatendemàexigência
mínimadecargaouusar-8ANS.ConsulteasEspecificações de carga.
A carga é inferior ao mínimo exigido.
•Verifiqueseascargasconectadasatendemàexigênciamínimado
controle.ConsulteoEspecificações de carga.
•Para-8S-DV,Verifiqueseascargasconectadasatendemàexigência
mínimadecargaouusar-8ANS.ConsulteasEspecificações de carga.
Lâmpadas estão queimadas ou não estão instaladas
•Substituaouinstaleaslâmpadas.
Lâmpadas de diodo
•Seestiveremsendousadaslâmpadasdediodo,substitua-aspor
lâmpadassemdiodo
Programação do ventilador
•Verifiqueseoventiladorestáprogramadoparasuamaisaltavelocidade
usandoacorrentedetração.
Tipo de carga errada no controle de velocidade de ventilador
•Confirmeseapenasumúnicoventiladordepásgiratóriasdeteto(motor
comcondensadorpermanente)classificadoem2Aoumenosestáligado
aocontrole.
•Verifiquesenenhumacargadeiluminação(i.e.kitdeluz)estáconectado
aocontrole.
Acargatremulaouchave
seletoranãofunciona,mesmo
seacargaforsuperiora40
W(somente-8S-DV)
Corrente de fuga
• Instale um condensador shunt.ConsulteoEsquema de ligações elétricas
4 ou 8.
Aluzacendeeapaga
continuamenteoualuz
acende(ON)quandoachave
seletoraépressionada,
apagandoemseguida(OFF)
A carga é inferior ao mínimo exigido.
•Verifiqueseascargasconectadasatendemàexigênciamínimadecarga.
ConsulteasEspecificações de carga.
•Instaleumcondensadorshuntcomo-8S-DV.ConsulteoEsquema de
ligações elétricas 4 ou 8.
•Para-8S-DV,Verifiqueseascargasconectadasatendemàexigência
mínimadecargaouusar-8ANS.ConsulteasEspecificações de carga.
Acargatremula(somente
-8S-DV)
A carga é inferior ao mínimo exigido.
•Verifiqueseascargasconectadasatendemàexigênciamínimadecarga.
ConsulteasEspecificações de carga.
Instale um condensador shunt.ConsulteoEsquema de ligações elétricas
4 ou 8.
Asluzes/ventiladoresnão
acendem/apagamapartirde
umteclado
Programação incorreta
•ProgramedeacordocomoGuia de configuraçãodosistema.
Fora da faixa de RF
Reposicione para estar dentro de um raio de 9 m (30 pés) deumrepetidor
desinaisdeRF.
Fiação
•Cabosemcurto.Verifiqueseoterminalazulnãoestáconectadoaoterra
ouemcurtocomalgumoutrocabo.
•Erronafiação.Verifiqueseafiaçãoestádeacordocomasinstruçõesde
instalaçãoeosdiagramasdeconexão.
Oespelhoestáquente Dissipação de controle de estado sólido
•Osdimmers/interruptores/controlesdevelocidadedeventiladores
deestadosólidodissipaminternamentecercade2%dacargatotal
conectada.Énormalqueosdimmers/interruptores/controlesde
velocidadedeventiladoresfiquemquentesduranteofuncionamento.
NOTA: Consulteo guiadeconfiguração do sistema para outras sugestões de solução de problemas.
Diagrama de montagem
Parafusos
deinstalação
docontrole
Caixade
embutir
Controle
Incluído:
Conectoresdecabos(1ou5)
Parafusosdeinstalação(2)
Parafusosde
montagemdo
adaptador
Adaptadordoespelho
eespelhovendidos
separadamente.
Adaptador
doespelho
Espelho
Cadacontroleteve
asabasinternas
removidas
Ocontrolenomeiodo
grupoestácomtodasas
abasremovidas
Não removaas
abasexternas
noscontroles
naextremidade
dogrupo.
LEDs de status (somente -F6AN-DV)
Indicaaintensidadedaluz;temumbrilholeve,como
umailuminaçãonoturna,quandoacargaestádesligada
Chave seletoraToqueparaligar/desligar
Controle de atenuação
Pressioneparaaumentaraintensidadede luz
ouparaaumentaravelocidade
Pressioneparareduziraintensidadedeluz
ouparareduziravelocidadede ventilador
FASS
Frente
Acessível
Serviço
Interruptor
Operação do dimmer / controle de
velocidade de ventilador
Operação do interruptor
LED de status (somente -8S-DV)
Indicaostatusdaluz;temum
brilhosuave,comoumailuminação
noturna,quandoacargaestá
desligada
Chave seletora
Toqueparaligar/desligar
FASS
Frente
Acessível
Serviço
Interruptor
-RD-277ou
-RS-277apenas
OR
OFF ON
Instalação
1
emumúnicolocalsemneutro
-6D,-10D(120V ~)
Esquema de ligações 1
Latão
Preto
Azul
1
Verde
Terra
Vivo
Neutro
Carga
Interruptor
120V~
50/60Hz
Instalação
1
emumúnicolocalcomneutro
-6NA,-10ND,-2ANFe-8ANS(120V ~)
Esquema de ligações 2
120V~
50/60Hz
Latão
Prata
Preto
Azul
1
Verde
Terra
Vivo
Neutro
Carga
Dimmer / Interruptor /
Controle de velocidade de ventilador
1
Aousarcontroleseminstalaçõesdeúnicolocal,aperteoterminalazulsemnenhumfioconectado.NÃOconecteoterminal
azulanenhumoutrofionemaoterra.
2
OcondensadorshuntdeveserinstaladonoladodalumináriadecargaouemumacaixaJseparada.
3
Instalaçãoapenasum(1)dimmer/interruptor/controledevelocidadedeventiladorporcircuito.Podemserconectadosno
dimmer/interruptor/controledevelocidadedeventiladoraté9dimmers/interruptoresremotos.Ocomprimentototaldocabo
doterminalazulpodechegara76m(250pés).
4
Osdimmers/interruptores/controlesdevelocidadedeventiladordefioneutrodevemserconectadosnoladodacargada
instalaçãoemvárioslocais.
Instalação
3
emvárioslocaiscomneutro
4
-6NAe-10ND,-2ANFcomRD-RD,-8ANScomRD-RS(120V~)
Esquema de ligações 6
Esquema de ligações 5
Latão
Prata
Preto
Azul
Verde
Terra
Carga
Latão
Preto
Azul
Verde
Terra
Dimmer remoto ou
interruptor remoto
120V~
50/60Hz
Latão
Preto
Azul
Verde
Terra
Vivo
Neutro
Dimmer remoto ou
interruptor remoto
NOTA: Odimmerdeveserinstalado
noladodacargadocircuito.
Instalação
3
dointerruptoremvárioslocaiscomneutro
-F6AN-DVcom-RDou-RD-277(120/277V ~)
Dimmer
Dimmer remotoDimmer remoto
NOTA: Odimmerdeveserinstalado
noladodacargadocircuito.
Latão/
Vermelho
Preto
Azul
Verde
Terra
Vivo
Neutro
120/277V~
50/60Hz
Preto
Laranja
Branco
Preto
Laranja
Branco
Latão
Preto
Azul
Verde
Terra
Laranja
Prata
Latão/
Vermelho
Preto
Azul
Verde
Terra
Instalação
3
dointerruptoremvárioslocaissemneutro
-8S-DVcom-RSou-RS-277econdensadorshuntopcional
2
(120-277V~)
Esquema de ligações 8
Preto
Azul
Verde
Terra
Carga
Interruptor
3
/ Interruptor
remoto
Preto
Azul
Verde
Terra
Interruptor
remoto / interruptor
3
Preto
Azul
Verde
Terra
Vivo
Neutro
Interruptor
remoto / interruptor
3
NOTA: Ointerruptorpodeserinstalado
emqualquerlugardocircuito.
120-277V~
50/60Hz
Opcional
Condensador
Shunt
2
Latão/
Vermelho
Latão/
Vermelho
Latão/
Vermelho
Instalação
3
emvárioslocaissemneutro
-6D,-10Dwith-RD(120V~)
Preto
Azul
Verde
Terra
Carga
Dimmer
3
/
dimmer remoto
Preto
Azul
Verde
Terra
Dimmer
remoto / dimmer
3
Preto
Azul
Verde
Terra
Vivo
Neutro
Dimmer
remoto / dimmer
3
NOTA: Odimmerpodeserinstalado
emqualquerlugardocircuito.
120V~
50/60Hz
Latão
Latão Latão
Instalação
1
emumúnicolocalcomneutro
-F6AN-DV(120/277V~)
Esquema de ligações 3
Latão
Preto
Azul
1
Verde
Terra
Vivo
Neutro
Dimmer
120/277V~
50/60Hz
Preto
Laranja
Branco
Laranja
Prata
Preto
Laranja
Branco
Comandoda
Lutron®do
balastro/LED
Comandoda
Lutron®do
balastro/LED
LutronElectronicsCo.,Inc.
7200SuterRoad|Coopersburg,PA18036-1299
P/N044-319Rev.B09/2012
Esteequipamentooperaemcarátersecundário,
istoé,nãotemdireitoàproteçãocontra
interferênciaprejudicial,mesmodeestaçoesdo
mesmotipoenãopodecausarinterferênciaa
sistemasoperandoemcaráterprimário.
(01) 07898525200110
0145-11-0905
Modelo: MRF2-3BRL-L
(01) 07898525200097
0839-11-6852
Modelo: RRD-10ND
(01) 07898525200219
3283-10-0905
Modelo: RRD-F6AN-DV
(01) 07898525200073
0839-11-6852
Modelo: RRD-6D
(01) 07898525200189
2854-10-0905
Modelo: RRD-8S-DV
(01) 07898525200103
0839-11-6852
Modelo: RRD-8ANS
(01) 07898525200080
0839-11-6852
Modelo: RRD-10D
Português
* Dimmer:
RRD-6D, -6NA, -10D, -10ND
(120V~50/60Hz)
RRD-F6AN-DV (120/277V~50/60Hz)
* Interruptor:
RRD-
8ANS
(120V~50/60Hz)
RRD-8S-DV (120-277V~50/60Hz)
* Interruptores remotos:
RD-RS (120
V~
50/60Hz)
RD-RS-277 (277
V~
50/60Hz)
* Condições de teste de consumo normal de energia:
Dimmer / Switch / Controle de velocidade de ventilador: 0,6 W
(Cargadesligada,modoluznoturnahabilitado.)
Dimmer / Interruptor remoto: 0 W(Cargadesligada.)
Para o Guia de configuração do sistema e
ferramentas, visite: www.lutron.com/radiora2
Especificações de carga
Controle Tipo de carga Carga mín. Carga máx.
-6D
1
Incand. 50W 600W
BTM
2
50W/VA
450W/
600VA
-6NA
1
Incand./BTE
2
5W 600W
BTM
2
5W/VA
450W/
600VA
-10D
1
Incand. 50W 1000W
BTM
2
50W/VA
800W/
1000VA
-10ND
1
Incand. 10W 1000W
BTM
2
10W/VA
800W/
1000VA
-F6AN-DV
3,4,5
Fluorecente/
LEDde3os
0,05A 6A
1balastro 60balastros
-2ANF
6
Ventilador
deteto
0,083A 2A
-8ANS
7
Iluminação 10W/VA 8A
Motor 0,08A
1/4HP
5,8A
-8S-DV
8,9
Iluminação 40W/VA 8A
Motor 0,4A
1/10HP
3A
-RD
10
Consultedimmer
8,3A
-RS
10
Consulteinterruptor
-RD-277
11
Consultedimmer
-RS-277
11
Consulteinterruptor
1 Tipo de carga de dimmer: Oscontroles -6D,-10De-10NDsó
devemserutilizadoscomcargasincandescentes,magnéticas
debaixatensãooudetungstênio-halogênioinstaladas
permanentemente.
Ocontrole-6NAsódeveserutilizadocomcargasincandescen-
tes,eletrônicosdebaixatensão,magnéticasdebaixatensãoou
detungstênio-halogênioinstaladaspermanentemente.
Nãoinstaledimmersparacomandartomadasouaparelhos
motorizados.Nãoépermitidomisturartiposdecarga
incandescente,halogênio,BTMouBTEemumdimmer.
2 Aplicações de baixa tensão:Useosmodelos-6D,-10D
e-10NDsomentecomtransformadoresmagnéticos(núcleo
ebobina)debaixatensão.Nãodevemserutilizadoscom
transformadoreseletrônicos(transistorizados)debaixatensão.
Useomodelo-6NAcomdimerizáveistransformadores
eletrônicos(transistorizados)oumagnéticos(núcleoebobina)
debaixatensão.
Elfuncionamientodeuncircuitodebajovoltajesinlámparas
oconlámparasquenofuncionanpuederesultarenelsobre-
calentamientodeltransformadoryfallasprematuras.Lutron
recomiendafirmementelosiguiente:
a.Nãousecircuitosdebaixatensãosemlâmpadasboas.
b.Substitualâmpadasasqueimadasomaisrápidopossível.
c.Usetransformadorescomproteçãotérmicaouenrolamentos
primárioscomfusívelparaevitarfalhasdevidoa
sobrecorrentes.
3 Dimmer de carga tipo fluorescente:
-F6AN-DV
foiprojetado
parausocomcontrolesdebalastrosfluorescentesoucomandos
deLEDscomvoltagemdelinhade120
V~
ou227
V~
de
trêscabosinstaladospermanentemente.Usesomentecom
Hi-lume®,Hi-lume®3D,
Hi-lume
®
A-Series,
CompactSE
,
Eco-10®,ouEcoSystem®(H3D-,FDB-,ECO-,HL3-,EC5-,L3D).
NÃOusecomqualqueroutrobalastrobalastrooucomando.Não
instaleparacontrolarreceptáculosouaplicaçõesoperadaspor
motor
.
4 Amplificador de potência – interfaces de carga: -6NA,
-10ND,-F6AN-DV,e-8ANSpodeserusadoparacontrolar
amplificadordepotência–interfacesdecarga.Paraobter
umalistadeamplificadordepotência–interfacesdecarga
compatíveisconsulteLutronP/N369225.
5 Carga máxima: Acagamáximaparao-F6AN-DVéacarga
reduzidaouonúmerodebalastros,oqueforMENOR.
6 Aplicação de ventilador de teto (-2ANF):
•Usarparacontrolarumventiladordetetodotipocompá
(condensadorpermanente)*.
•Usaracorrentedetraçãodoventiladordetetopara
programarsuavelocidadeparaamaisalta*.
•Nãousarparacontrolarventiladoresqueusammotores(i.e.
ventiladoresdeexaustãodebanheiro)*.
•Nãousarparacontrolarventiladoresquetêmcontrolesde
velocidadeintegrados(i.e.ventiladoresquetêmcontrole
remoto),amenosqueocontroleintegradotenhasidoremovi-
dodoventiladordeteto*.
•Nãoconectaranenhumoutroequipamentooperadopor
motorouaqualqueroutrotipodecargadeiluminação.
•Nãousarparacontrolarumacargadeiluminaçãode
ventilador(i.e.kitdeluz).
7 Tipo de carga do interruptor -8ANS: -8ANSéumtipo
projetadosparausocomtodasascargasincandescentes,
magnéticasdebaixatensão,eletrônicosdebaixatensãooude
fluorescentesinstaladaspermanentementeecomcargasde
motordeaté1/4HP(5,8A).
8 Tipo de carga do interruptor -8S-DV: -8S-DVfoiprojetado
parausocomcargasincandescentespermanentemente
instaladasde120V~,baixavoltagemmagnética,baixa
voltagemeletrônicaoucargasdemotores;oucargas
fluorescentesoubaixavoltagemmagnéticade277V~.
9 Condensador Shunt (incluído): Algumasinstalaçõesdo
-8S-DVpodemexigirousodeumcondensadorshunt.Istoé
necessárioparatiposdecargassensíveisàcorrentedefuga
(ouseja,balastrosfluorescentes).Secargatremula,instaleum
condensadorshunt.Paraainstalaçãodo
condensadorshunt,
consulteoEsquema de ligações elétricas 4 ou 8.
10 Dimmer / interruptor remoto 120 V~: -RDe-RSforam
projetadosparausocomdimmers/interruptores120V~.
11 Dimmer / interruptor remoto 277 V~:
-RD-277e-RS-277foramprojetadosparausocomdimmers/
interruptores277V~.NÃOusecomcargasdemotor.
Tipo designer RF Maestro®
* Controle de velocidade de ventilador:
RRD-2ANF (120
V~
50/60Hz)
* Dimmers remotos:
RD-RD (120
V~
50/60Hz)
RD-RD-277 (277
V~
50/60Hz)
Dimmer Interruptor
Interruptour
remoto
Dimmer
remoto
Controlede
velocidadedeventilador
Dimmer
mostrado
Instalação
1
emumúnicolocalsemneutro
-8S-DVcomcondensadorshuntopcional
2
(120-277V~)
Esquema de ligações 4
Latão
Preto
Azul
1
Verde
Terra
Carga
Interruptor
120-277V~
50/60Hz
Condensador
Shunt
2
Opcional
Neutro
Dimmer / Interruptor /
Controle de velocidade de ventilador
Esquema de ligações 7
Vivo
Comandoda
Lutron®do
balastro/LED
Comandoda
Lutron®do
balastro/LED

Transcripción de documentos

Control Load Specifications -6D1 1 -6NA -10D1 -10ND1 -F6AN-DV3, 4, 5 -2ANF6 -8ANS7 -8S-DV8, 9 Load Type Min. Load Max. Load Incand. 50 W 600 W MLV2 50 W / VA 450 W / 600 VA Incand./ ELV2 5W 600 W MLV2 5 W / VA 450 W / 600 VA Incand. 50 W 1000 W MLV2 50 W / VA 800 W / 1000 VA Incand. 10 W 1000 W MLV2 10 W / VA 800 W / 1000 VA 3-wire Fluorescent/ LED 0.05 A 6A 1 ballast 60 ballasts Ceiling Fan 0.083 A 2A Lighting 10 W / VA 8A Motor 0.08 A 1/4 HP 5.8 A Lighting 40 W / VA 8A Motor 0.4 A 1/10 HP 3A -RD10 See Dimmer -RS10 See Switch -RD-27711 See Dimmer -RS-27711 See Switch 8.3 A 1 Dimmer Load Type: -6D, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen only. -6NA is designed for use with permanently installed incandescent, electronic low-voltage, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. Do not mix incandescent, halogen, MLV, or ELV load types on a dimmer. 2 Low-Voltage Applications: Use -6D,-10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers.  Use -6NA with dimmable electronic (solid-state) or magnetic (core and coil) transformers.  Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: a. Do not operate low-voltage circuits without operative lamps in place. b. Replace burned-out lamps as quickly as possible. c. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Fluorescent Dimmer Load Type: -F6AN-DV is designed for use with permanently installed 3-wire 120 V~ or 277 V~ line voltage control fluorescent ballasts or LED drivers. Use only with Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances. -6D Dimmer -6NA Switch -10D, -10ND Remote Dimmer -F6AN-DV* Remote Switch Fan Speed Contol Important Notes WARNING – Entrapment Hazard – To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Codes: Install in accordance with all local and national electrical codes. Grounding: When no “grounding means” exist in wallbox, the 2011 National Electrical Code® (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox. Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, noncondensing. Indoor use only. Spacing: If mounting one control above another, leave at least 4 ½ in (114 mm) vertical space between them. 5 Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS. Wallplates: Lutron® Claro® and Satin Colors® wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates. 7 Switch Load Type -8ANS: -8ANS is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A). 8 Switch Load Type -8S-DV: -8S-DV is designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, fluorescent, or motor loads; or 277 V~ magnetic low-voltage or fluorescent loads. 9 Shunt Capacitor (included): Some -8S-DV installations may require the use of a shunt capacitor. This is especially necessary for load types sensitive to leakage current (i.e. fluorescent ballasts). If load flickers, install a shunt capacitor. For shunt capacitor installation see Wiring Diagram 4 or 8. 10 120 V~ Remote Dimmer / Switch: -RD and -RS are designed for use with 120 V~ dimmers / switches. 11 2  77 V~ Remote Dimmer / Switch: -RD-277 and -RS-277 are designed for use with 277 V~ dimmers / switches. Do NOT use with motor loads. * Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions. Wallboxes: Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier installation. Several controls may be installed in one multigang wallbox. See Derating Chart. Remotes: Use only remote dimmers (-RD / -RD-277) and remote switches (-RS / -RS-277)with dimmers /switches / fan speed controls. Up to 9 -RD / -RD-277 or -RS / -RS-277 may be used with controls. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF dimmers /switches and fan controls must be located within 30 ft (9 m) of an RF Signal Repeater. Remote dimmers / switches are not required to be within a specific range of a repeater. For systems with an RF signal repeater, RF dimmers / switches / fan speed controls cannot be controlled by the system until they are programmed in a system according to the system Setup Guide. Typical Power Consumption: Dimmer / Switch / Fan Speed Control: 0.6 W (Load is off, nightlight mode enabled.) Remote Dimmer / Switch: 0 W (Load is off.) Technical Assistance: U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910 Brazil: +55 (11) 3257-6745 (M-F 8:30 to 17:30 BRT) | Other Countries: +1.610.282.3800 24 hours a day, 7 days a week www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012 -8ANS Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m). Load Type End of Gang Middle of Gang Incand. 500 W 400 W MLV 400 W / 500 VA 300 W / 400 VA Incand./ ELV 500 W 400 W b. W  ire Connectors: Prepare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector. MLV 400 W / 500 VA 300 W / 400 VA NOTE: Wire connectors provided are suitable for copper wire only. Incand. 800 W 650 W MLV 600 W / 800 VA 500 W / 650 VA • S  trip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wire. 3-wire Fluorescent/ LED 5A 3.5 A 50 ballasts 35 ballasts • S  trip insulation 7/16 in (11 mm) for 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire. Ceiling Fan 2A 2A Lighting 6.5 A 5A Motor 1/4 HP 5.8 A 1/6 HP 4.4 A Lighting 8A (2-gang) 7A (3-gang) 7A -8S-DV Motor Wire Connector: • U  se to join one or two 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wires with one 18 AWG (0.75 mm2) or 16 AWG (1.0 mm2) wire. *T  he maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS. NOTE: -8ANS, -RD-277 and -RS-277 controls have fins that need to be removed for multigang installations. -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS controls do not have fins that need to be removed for multigang installations. Wiring Diagram 2 Single Location Installation1 without Neutral -6D, -10D (120 V~) Single Location Installation1 with Neutral -6NA, -10ND, -2ANF and -8ANS (120 V~) Dimmer Brass Control at middle of gang has all fins removed • Push-In Terminals: Use with 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire. Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in terminal. Push screwdriver in while pulling wire out. OR Probable Cause and Action Light / fan doesn’t turn ON / OFF when tapswitch on dimmer / switch / fan speed control or remote dimmer / switch is pressed Power not present • Circuit breaker OFF or tripped. Perform short circuit check. • FASS™ is in the OFF position. Move FASS™ to the ON position. Check the dimmer / switch / fan speed control and all of the remote dimmers / switches. See Lamp Replacement. Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or-8ANS. See Load Specifications. Load Ground Wiring Diagram 3 Wiring Diagram 4 Single Location Installation1 with Neutral -F6AN-DV (120/277 V~) Single Location Installation1 without Neutral -8S-DV with optional shunt capacitor2 (120-277 V~) Dimmer Brass Hot/Live Silver Black Orange White Blue 1 Orange Black Green 120/277 V~ 50/60 Hz Black Orange White Ground Neutral Load is less than minimum load requirement • Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications. Switch Blue 1 Brass Hot/Live Black Lamps burned out or not installed • Replace or install lamps. Optional Green 120-277 V~ 50/60 Hz Shunt Capacitor2 Load Dioded lamps • If dioded lamps are being used, replace with non-dioded lamps. Ground Neutral Fan setting • Make sure the fan is set to its highest speed using the pull-chain. Fan Speed Control Wrong Load Type • Make sure that only a single ceiling paddle fan (permanent split-capacitor motor) rated at 2 A or less is connected to the control. • Make sure that no lighting load (i.e. light kit) is connected to the control. Wiring Diagram 5 Multi-Location Installation3 without Neutral -6D, -10D with -RD (120 V~) Blue Brass Black Green Dimmer / Remote Dimmer3 Blue Brass Blue Black Green NOTE: Dimmer may be installed in any location in the circuit. Green Load Ground Ground Neutral Load flickers or tapswitch does not work even if load is greater than 40 W (-8S-DV only) Leakage current • Install a shunt capacitor. See Wiring Diagram 4 or 8. Light turns ON and OFF continuously or lights turn ON when tapswitch is pressed, then turn OFF Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor with -8S-DV. See See Wiring Diagram 4 or 8. • For -8S-DV, increase load to meet the appropriate minimum load requirement or use shunt capacitor or -8ANS. See Load Specifications. Load flickers (-8S-DV only) Load does not meet the minimum load requirement • Increase load to meet the appropriate minimum load requirement for that control. See Load Specifications. • Install a shunt capacitor. See Wiring Diagram 4 or 8. Lights/Fans don’t turn ON/ OFF from a keypad Improper programming • Program according to the system Setup Guide. Wiring Diagram 6 4. P  ush all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires. a. Install wallplate adapter onto front of control(s). Multi-Location Installation3 with Neutral4 -6NA, -10ND, and -2ANF with RD-RD, and -8ANS with RD-RS (120 V~) Remote Dimmer/ Remote Switch Brass Brass Blue Black Green 120 V~ 50/60 Hz Black Black Green Ground Blue Brass Silver Blue Hot/Live c. Snap wallplate onto wallplate adapter, and verify that control is aligned properly. Multi-Location Dimmer Installation3 with Neutral 4 -F6AN-DV with -RD or -RD-277 (120/277 V~) Remote Dimmer Brass/ Red Remote Dimmer Ground Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Black Blue Brass/ Red Black Green 120/277 V~ 50/60 Hz Wallplate is warm NOTE: Dimmer must be installed on the load side of the circuit. Dimmer Brass Blue Silver Hot/Live Black Green Ground Ground Wallplate Wallplate Control Adapter Adapter Mounting Mounting Screws Screws Out of RF range • Reposition to be within 30 ft (9 m) of an RF signal repeater. Load Neutral Black Orange White Blue Orange Green Black Orange White Ground Neutral Mounting Diagram NOTE: Dimmer must be installed on the load side of the circuit. Green Ground Wiring Diagram 7 6. R  estore power. Verify correct local operation. See Dimmer/Fan Operation or Switch Operation. Dimmer / Switch / Fan Speed Control Remote Dimmer/ Remote Switch b. Tighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten). Solid-state control dissipation • Solid-state dimmers / switches / fan speed controls internally dissipate about 2% of the total connected load. It is normal for dimmers / switches / fan speed controls to feel warm to the touch during operation. NOTE: Refer to the system Setup Guide for additional troubleshooting suggestions. Wiring Diagram 8 Multi-Location Installation 3 without Neutral -8S-DV with -RS or -RS-277 and optional shunt capacitor2 (120– 277 V~) Remote Switch / Switch3 Brass/ Red Remote Switch / Switch3 Brass/ Red Blue Blue Switch / Remote Switch3 Brass/ Red NOTE: Switch may be installed in any location in the circuit. Blue Hot/Live Wallbox Included: Black 120–277 V~ 50/60 Hz Control Wire Connectors (1 or 5) Mounting Screws (2) Wallplate adapter and wallplate purchased separately. 3. W  ire controls according to one of the following options: a. T  erminals: Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control. Green 120 V~ 50/60 Hz Symptom Neutral Ground 1. Turn power OFF at fusebox or circuit breaker. 2. C  heck the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights or fans do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit. Black Load Ground Neutral 120 V~ 50/60 Hz Installation WARNING – Shock Hazard – To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death. Silver Hot/Live Green Brass For single and multi-location installations see Wiring Diagrams. Blue 1 Brass 120 V~ 50/60 Hz d. If controls are misaligned, loosen mounting screws appropriately. Each control has inside fins removed Blue 1 Black Troubleshooting Guide Dimmer/Switch/ Fan Speed Control Hot/Live Hot/Live Black 5. A  ttach the Lutron® Claro® or Satin Colors® wallplate adapter and wallplate. See Mounting Diagram. Do Not remove outside fins on controls at the end of gang Wiring Diagram 1 Remote Dimmer / Dimmer3 Remote Dimmer / Dimmer3 Twist wire connector tight. 1/10 HP 3A Neutral Wire: -6NA, -10ND, -F6AN-DV, -2ANF, and -8ANS require a neutral wire connection in the wallbox where the dimmer/switch/fan control is to be installed. If a neutral wire connection is not available in the wallbox, contact a licensed electrician for installation. 4 Power Boosters / Load Interfaces: -6NA, -10ND, -F6AN-DV, and -8ANS can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Lutron P/N 369225. 6  Ceiling Fan Application (-2ANF): • Use to control one paddle-type ceiling fan (permanent split-capacitor). • Use the ceiling fan’s pull chain to set its speed to the highest setting. • Do not use to control fans that use shaded-pole motors (i.e. bath exhaust fans). • Do not use to control fans that have integrated fan speed controls (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan. • Do not connect to any other motor-operated appliance or to any lighting load type. • Do not use to control a fan lighting load (i.e. light kit). -2ANF • S  crew Terminals: Use with 12 AWG (2.5 mm2) or 14 AWG (1.5 mm2) solid copper wire only. Do NOT use stranded or twisted wire. Lutron® Ballast / LED Driver Derating Chart For system Setup Guide and tools visit www.lutron.com/radiora2 Control When combining controls in a wallbox, derating is required; however, no derating is required for fan speed controls and remote dimmers / switches. Lutron® Ballast / LED Driver In multigang installations, several controls are grouped horizontally in one multigang wallbox. * Remote Switches: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Lutron® Ballast / LED Driver Multigang Installations Please Read Before Installing * Fan Speed Control: RRD-2ANF (120 V~ 50 / 60 Hz) * Remote Dimmers: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Lutron® Ballast / LED Driver English Installation Instructions Designer-Style RF Maestro® * Dimmer: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Switch: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Lamp Replacement WARNING – Shock Hazard – For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or death. Black Black Green Green Green Ground Ground Ground Optional Load Shunt Capacitor2 Neutral 1 When using controls in single location installations, tighten the blue terminal without any wires attached. DO NOT connect the blue terminal to any other wiring or to ground. 2 Shunt capacitor must be installed inside the load fixture or in a separate J-box. 3 Install only 1 dimmer / switch / fan speed control per circuit. Up to 9 remote dimmers / switches may be connected to a dimmer / switch / fan speed control. Total blue terminal wire length may be up to 250 ft (76 m). 4 Neutral wire dimmers / switches / fan speed controls must be connected on the Load side of a multi-location installation. Dimmer/Fan Operation For your safety during routine lamp replacement, remove power from the fixture(s) by moving the FASS™ switch into the OFF position on the dimmer / switch and all remote dimmers / switches. Dimmer Shown Switch Operation Status LEDs Indicate light level; glows softly as night light when load is off Tapswitch Tap on/off Status LED Indicates light status; glows softly as night light when load is off Dimming Rocker Press to Brighten or Increase Speed Press to Dim or Decrease Speed Tapswitch Tap on/off FASS™ Front Accessible Service Switch Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, and ) are registered trademarks and RadioRA 2, Compact SE, and FASS are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc. FASS™ Front Accessible Service Switch -RD-277 or -RS-277 only OR OFF ON Return to Factory Settings NOTE: Returning a dimmer / switch / fan speed contol to its factory settings will remove it from the system and erase all programming from it. Step 1 : T  riple tap the tapswitch on a control. DO NOT release after the third tap. Step 2 : K  eep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer start to scroll up and down quickly, or the LED on the switch flashes quickly Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The LEDs on the dimmer will scroll up and down slowly. The LED on the switch will flash slowly. The control has now been returned to factory settings and needs to be reprogrammed into a system. Warranty: See the Warranty enclosed with the product, or visit www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf Instalaciones con múltiples dispositivos * Interruptores accesorios: RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Para la Guía de configuración del sistema y otras herramientas visite: www.lutron.com/radiora2 Especificaciones de la carga Control -6D1 -6NA1 -10D1 -10ND1 Tipo de carga Carga mín. Carga máx. Incand. 50 W 600 W BVM2 50 W / VA 450 W / 600 VA Incand./ BVE2 5W 600 W BVM2 5 W / VA 450 W / 600 VA Incand. 50 W 1 000 W BVM2 50 W / VA 800 W / 1 000 VA Incand. 10 W 1 000 W BVM2 10 W / VA 800 W / 1 000 VA 0,05 A Fluorescente de 3 -F6AN-DV3, 4, 5 conductores / LED 1 balasto -2ANF6 -8ANS7 -8S-DV8, 9 -RD10 6A 60 balastos Ventilador de techo 0,083 A 2A Iluminación 10 W / VA 8A Motor 0,08 A 1/4 HP 5,8 A Iluminación 40 W / VA 8A Motor 0,4 A 1/10 HP 3A Ver el Atenuador -RS10 Vea Interruptor 11 -RD-277 Ver el Atenuador -RS-27711 Vea Interruptor 8,3 A 1 Tipo de carga del atenuador: Los modelos -6D, -10D y -10ND están diseñados para usarse solamente con cargas incandescentes, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente. El modelo -6NA está diseñado para usarse solamente con cargas incandescentes, electrónicos de bajo voltaje, magnéticas de bajo voltaje, o halógenas de tungsteno instaladas en forma permanente. No instale atenuadores para controlar tomas de corriente ni dispositivos motorizados. No combinar tipos de carga incandescente, halógena, BVM o BVE en un atenuador. 2 Uso con bajo voltaje: Use los modelos -6D, -10D y -10ND solamente con transformadores magnéticos (de bobina y núcleo) de bajo voltaje. No los use con transformadores electrónicos (de estado sólido). Use el modelo -6NA con transformadores atenuables electrónicos (de estado sólido) o magnéticos (de bobina y núcleo) de bajo voltaje. El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. No opere circuitos de bajo voltaje sin las lámparas en condiciones operativas en su lugar. b. Reemplace las lámparas quemadas lo más rápido posible. c. Use transformadores que incorporan protección térmica o con fusibles en los bobinados primarios para prevenir fallas del transformador provocadas por sobrecorrientes. 3 Tipo de carga del atenuador para luces fluorescentes: El -F6AN-DV está diseñado para ser usado con drivers de LED o balastos de luces fluorescentes de 3 conductores, de 120 V~ o 277 V~, instalados en forma permanente y controlados a través del voltaje de línea. Use sólo con Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, o EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NO usar con otros balastos o drivers. No lo instale para controlar tomas de corriente ni electrodomésticos operados por motor. 4 Amplificadores de potencia / Interfaces de carga: -6NA, -10ND, -F6AN-DV, y -8ANS se pueden utilizar para controlar amplificadores de poder/interfaces de carga. Para obtener una lista de amplificadores de poder/interfaces de carga compatibles, consulte Lutron P/N 369225. 5 Carga Máxima: La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR. 6 Aplicación de ventilador de techo (-2ANF): • Use para controlar un ventilador de techo de paletas (decondensador permanente). • Use la cadena del ventilador de techo para configurar su velocidad en el valor más alto posible. • No use para controlar ventiladores que usan motores de anillos de desfase (como extractores). • No use para controlar ventiladores que tienen un control de velocidad integrado (por ejemplo ventiladores que tienen un control remoto), a menos que el control integrado se remueva del ventilador de techo. • No conecte ningún otro dispositivo operado a motor o ningún tipo de carga de iluminación. • No lo use para controlar una carga de iluminación de ventilador (por ejemplo juego de luz). 7 Tipo de carga del interruptor -8ANS: el modelo -8ANS está diseñado para usar con cargas incandescentes, de bajo voltaje magnético, de bajo voltaje electrónico, o fluorecentes instaladas en forma permanente y con cargas de motores de hasta 1/4 HP (5,8 A). 8  Tipo de carga del interruptor -8S-DV: El -8S-DV está diseñado para uso con cargas permanentemente instaladas de 120 V~, incandescentes, de bajo voltaje magnético o electrónico, fluorescentes, o motores; o con cargas de 277 V~, fluorescentes o de bajo voltaje magnético). 9  Condensador paralelo (incluido): ciertas instalaciones -8S-DV pueden requerir el uso de un condensador paralelo. Esto es especialmente necesario con tipos de carga sensibles a la corriente de fuga (por ejemplo balastos fluorescentes). Si la carga parpadea, instale un condensador en paralelo. Para la instalación del condensador paralelo vea el Diagrama de cableado 4 o 8. 10  Atenuador / interruptor accesorio de 120 V~: Los -RD y -RS están diseñados para usar con atenuadores / interruptores de 120 V~. 11  Atenuador / interruptor accesorio de 277 V~: Los -RD-277 y -RS-277 están diseñados para usar con atenuadores / interruptores de 277 V~. NO utilizar con una carga motorizada. *Condiciones de la prueba de consumo típico de potencia: Dimmer / Switch / Control de velocidad de ventilador: 0,6 W (la carga está apagada, el modo de luz nocturna está habilitado.) Atenuador / Interruptor accesorio: 0 W (La carga está apagada.) Cuando se combinan controles en una caja de empotrar se requiere reducir la potencia nominal. Atenuador Envuelva el cable alrededor del tornillo del terminal. Apriete con firmeza hasta 0,55 N•m (5 pulg-lbs). Cuadro de reducción de la potencia nominal b. C  onectores de cable: Prepare los cables. Al hacer conexiones de cable, siga las longitudes para extremos pelados y las combinaciones recomendadas para los conectores proporcionados. -6D Interruptor -6NA -10D, -10ND Atenuador accesorio Interruptor accesorio Control de velocidad de ventilador Notas importantes ADVERTENCIA – Riesgo de quedar atrapado – Para evitar el riesgo de quedar atrapado, de lesiones graves o la muerte, estos controles no deben usarse para controlar equipos que no sean visibles desde todos los puntos de control o que puedan causar situaciones peligrosas, como quedar atrapado, si se operan accidentalmente. Como ejemplos de equipos que no deben operarse con estos controles podemos citar (sin limitación) portones motorizados, puertas de garaje, puertas industriales, hornos de microondas, almohadillas de calentamiento, etc. Es responsabilidad del instalador asegurar que el equipo que se controla sea visible desde todos los puntos de control y que sólo se conecten equipos adecuados a estos controles. La falta de cumplimiento podría resultar en lesiones graves o la muerte. Códigos: Realice la instalación de acuerdo con todos los códigos eléctricos locales y nacionales. Conexión a tierra: Cuando dentro de la caja de empotrar no hay “medios de conexión a tierra”, el National Electrical Code® 2011 permite la instalación de un control como reemplazo, siempre y cuando 1) se utilice una placa frontal no metálica e incombustible con tornillos de fijación no metálicos o 2) el circuito se encuentre protegido por un interruptor de circuitos de fallas de conexión a tierra (GFCI). Al instalar un control de acuerdo con estos métodos, tape o retire al cable verde antes de atornillar el control en la caja de empotrar. Cables neutros: Los modelos -6NA, -10ND, -F6AN-DV, -2ANF, y -8ANS requieren una conexión de neutro en la caja de empotrar en que se instalará el atenuador/interruptor/control de ventilador. Si no hay disponible una conexión de neutro en la caja de empotrar, contacte a un electricista autorizado para instalarlo. Condiciones ambientales: Temperatura ambiente de operación: de 0 ºC a 40 °C (32 °F a 104 °F), humedad de 0% a 90%, sin condensación. Sólo para uso en interiores. Espaciado: Si se monta un control sobre otro, deje por lo menos 114 mm (4 ½ pulg) de espacio vertical entre ellos. Placas: Las placas Claro® y Satin Colors® de Lutron® se recomiendan para una mejor combinación de colores y aspecto estético. No pinte los controles ni las placas. Limpieza: Para limpiar, pase un trapo húmedo. NO use ninguna solución química. Cajas de empotrar: Para facilitar la instalación, Lutron recomienda el uso de cajas de empotrar de 89 mm (3 ½ pulg) de profundidad. Varios controles pueden instalarse en una caja para dispositivos múltiples – vea el Cuadro de Reducción de la Potencia Nominal. Atenuadores / Interruptores remotos: utilice solamente los atenuadores remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) con atenuadores / interruptores / control de velocidad de ventilador. Con estos atenuadores o interruptores pueden usarse hasta 9 -RD / -RD-277 o -RS / -RS-277. Los interruptores mecánicos de 3 o 4 vías no funcionarán. Ubicación del dispositivo de RF: los atenuadores / interruptores y controles de velocidad de ventilador de RF deben ubicarse a menos de 9 m (30 pies) de un repetidor de señales de RF. Los atenuadores / interruptores accesorios no están sujetos a esta limitación de estar ubicados a cierta distancia de un repetidor. En sistemas con un repetidor de señal de RF, los atenuadores / interruptores / control de velocidad de ventilador de RF no pueden ser controlados por el sistema hasta que hayan sido programados de acuerdo con la Guía de configuración del sistema. • T  erminales de tornillo: Use solamente con cables de cobre sólidos de 2,5 mm2 (12 AWG) ó 1,5 mm2 (14 AWG). NO utilice cable retorcido ni trenzado. Esto no es necesario para los controles de velocidad del ventilador y atenuadores / interruptores accesorios. Control Asistencia técnica: E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 Brasil: +55 (11) 3257-6745 (Lunes-Viernes 8:30 to 17:30 BRT) | Otros países: +1.610.282.3800 24 horas al día, los 7 días de la semana www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012 En instalaciones con dispositivos múltiples, se agrupan varios controles horizontalmente en una caja de empotrar para dispositivos múltiples. Tipo de carga Extremos de la agrupación Medio de la agrupación Incand. 500 W 400 W BVM 400 W / 500 VA 300 W / 400 VA Incand./ BVE 500 W 400 W BVM 400 W / 500 VA 300 W / 400 VA Incand. 800 W 650 W BVM 600 W / 800 VA 500 W / 650 VA -F6AN-DV* Fluorescente de 3 conductores / LED 5A 3,5 A 50 balastos 35 balastos -2ANF Ventilador de techo 2A 2A Iluminación 6,5 A 5A Motor 1/4 HP 5,8 A 1/6 HP 4,4 A Iluminación 8A (2-dispositivos) 7A (3-dispositivos) 7A Motor 1/10 HP 3A -8ANS -8S-DV * La carga máxima para el -F6AN-DV es la carga reducida o el número de balastos, lo que fuera MENOR. NOTA: Los controles -8ANS, -RD-277 and -RS-277 tienen aletas que se deben quitar para instalaciones de dispositivos múltiples. Los controles -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS no tienen aletas que deban quitarse para instalaciones de dispositivos múltiples. No quite las aletas exteriores de los controles en ambos extremos de la agrupación NOTA: Los conectores provistos son para cable de cobre solamente. Conector de cable: • Pele 10 mm (3/8 pulg) de aislamiento para cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG). • P  ele 11 mm (7/16 pulg) de aislamiento para cables de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG). • Use para unir uno o dos cables de 1,5 mm2 (14 AWG) o 2,5 mm2 (12 AWG) con un cable de 0,75 mm2 (18 AWG) o 1,0 mm2 (16 AWG). Al control en medio de la agrupación se le han quitado todas las aletas Instalación ADVERTENCIA – Peligro de descarga eléctrica – Para evitarla, ubique y retire el fusible o asegure el disyuntor en la posición de APAGADO antes de proceder. Cablear con la alimentación ENCENDIDA podría causar lesiones graves o la muerte. 1. DESCONECTE la alimentación en la caja de fusibles o en el disyuntor. 2. V  erifique que no haya cortocircuitos en la instalación antes de instalar el(los) control(es). Con la alimentación DESCONECTADA, instale interruptores mecánicos estándar entre el vivo y la carga. Restablezca la alimentación. Si las luces o ventiladores no funcionan o un disyuntor se dispara, corrija el cableado y verifique nuevamente. Instale el(los) control(es) solamente cuando ya no haya cortocircuito. La garantía es nula si el control se ENCIENDE con un cortocircuito. 3. Cablee los controles de acuerdo con una de las opciones siguientes: a. T  erminales: Recorte o pele los cables de la caja de empotrar hasta la medida indicada en el reverso del control. • Terminales de insertar: Use únicamente con cables de cobre sólido de 1,5 mm2 (14 AWG). NO utilice cable trenzado ni retorcido. Inserte completamente los cables. Para soltar el cable, inserte un destornillador chato pequeño dentro de la ranura debajo del terminal a presión. Empuje el destornillador mientras tira el cable hacia afuera. O Diagrama de cableado 2 Instalación1 en un solo lugar sin neutro -6D, -10D (120 V~) Instalación1 en un solo lugar con neutro -6NA, -10ND, -2ANF y -8ANS (120 V~) Latón Azul 1 Vivo Gire el conector de cable para afirmarlo Latón Plata Vivo Negro Azul 1 Negro Verde 120 V~ 50/60 Hz Guía para la solución de problemas Atenuador / interruptor / Control de velocidad de ventilador Interruptor Verde 120 V~ 50/60 Hz Carga Tierra Carga Tierra Neutro Síntoma Probable Causa y Acción Luz / ventilador no se ENCIENDEN / APAGAN cuando se presiona el interruptor de presión del atenuador / interruptor / control de velocidad de ventilador o del atenuador / interruptor accesorio. No hay alimentación • Disyuntor APAGADO o se disparó. Verifique si hay cortocircuito. • Interruptor FASS™ en la posición de APAGADO. Cambie el FASS™ a la posición de ENCENDIDO. Verifique el atenuador / interruptor / control de velocidad de ventilador y todos los atenuadores / interruptores accesorios. Consulte Reemplazo de lámparas. Neutro Diagrama de cableado 3 Diagrama de cableado 4 1 Instalación en un solo lugar sin neutro -8S-DV con condensador paralelo opcional2 (120-277 V~) 1 Instalación en un solo lugar con neutro -F6AN-DV (120/277 V~) Atenuador Latón Vivo Plateado Negro 120/277 V~ 50/60 Hz Interruptor Negro Naranja Blanco Azul1 Naranja Verde Negro Naranja Blanco Tierra Neutro Latón Negro Opcional Verde 120-277 V~ 50/60 Hz Condensador paralelo2 Carga Tierra Neutro Las lámparas están quemadas o no están instaladas. • Reemplace o instale lámparas. Lámparas de diodo • Si se están usando lámparas de diodo, reemplácelas por lámparas sin diodos. Instalación de un interruptor en múltiples ubicaciones3 -6D, -10D with -RD (120 V~) Latón Atenuador accesorio/ Atenuador3 Azul Latón Azul Atenuador3/ Atenuador accesorio Latón Configuración del ventilador • Asegúrese que el ventilador está en su velocidad máxima utilizando la cadena. NOTA: El attenuador puede ser instalado en cualquier lugar del circuito. Azul Tipo de carga incorrecto del control de velocidad del ventilador • Asegúrese que solamente un único ventilador de paletas (motor de condensador permanente) de 2 A o menos está conectado al control. • Asegúrese que ninguna carga de iluminación (por ejemplo un juego de luz) está conectado al control. Vivo Negro Negro Verde 120 V~ 50/60 Hz Verde Carga Tierra Para instalaciones en una sola y múltiples ubicaciones vea el diagramas de cableado. Verde Negro Tierra Tierra Neutro Diagrama de cableado 6 4. Inserte todos los cables en la caja de empotrar y coloque el control en la caja usando los tornillos de montaje provistos. No pellizque los cables. 5. C  oloque el adaptador y la placa Lutron® Claro® o Satin Colors®. Consulte Diagrama de montaje. Instalación3 con control desde varios lugares, con neutro4 -6NA, -10ND, -2ANF con RD-RD, y -8ANS con RD-RS (120 V~) Atenuador accesorio/ interruptor accesorio Latón Negro 120 V~ 50/60 Hz b. Ajuste los tornillos de montaje del control hasta que el adaptador de placa esté a ras con la pared (no los sobreajuste). Neutro 6. R  establezca la alimentación. Verifique que el funcionamiento local sea correcto. Consulte Operación del atenuador / ventilador u Operación del interruptor. Atenuador accesorio/ interruptor accesorio Latón Atenuador / interruptor / Control de velocidad de ventilador Azul Latón Plata Vivo a. Instale el adaptador de la placa sobre el frente del (los) control(es). d. Si los controles quedaron mal alineados, afloje los tornillos de montaje según corresponda. Azul Verde Negro Verde Tierra Diagrama de cableado 7 Instalación3 de un atenuador en múltiples ubicaciones con neutro4 -F6AN-DV con -RD o -RD-277 (120/277 V~) Atenuador accesorio Latón/ Rojo Vivo Negro 120/277 V~ 50/60 Hz Azul Atenuador accesorio Latón/ Rojo Azul Negro Atenuador Latón Plateado Negro Azul Naranja Verde Verde Verde Tierra Tierra Tierra NOTA: El atenuador debe ser instalado del lado de la carga del circuito Negro Naranja Blanco Negro Naranja Blanco Adaptador Placa de placa Tornillos de Tornillos de montaje del montaje del control adaptador Latón/ Rojo Latón/ Rojo Azul Azul Azul La carga no cumple con los requisitos de carga mínima • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador en paralelo con el -8S-DV. Vea el Diagrama de cableado 4 o 8. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga. La carga parpadea (-8S-DV solamente) La carga no cumple los requisitos mínimos de carga • Aumente la carga para cumplir con los requisitos de carga mínima de ese control. Vea Especificaciones de la carga. • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8. Las luces / ventiladores no se ENCIENDEN/APAGAN desde un teclado Programación incorrecta • Programe todos los dispositivos según la Guía de configuración del sistema. La placa de pared está caliente Interruptor3/ Interruptor accesorio Latón/ Rojo La luz se ENCIENDE y se APAGA continuamente o las luces se ENCIENDEN cuando se presiona el interruptor, luego se APAGAN Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado. Instalación de un interruptor en múltiples ubicaciones3 -8S-DV con -RS o -RS-277 y condensador paralelo opcional2 (120– 277 V~) Interruptor accesorio/ Interruptor3 Corriente de fuga • Instale un condensador paralelo. Vea el Diagrama de cableado 4 o 8. Fuera del alcance de RF • Reubique para estar a no más de 9 m (30 pies) de un repetidor de señales de RF. Diagrama de cableado 8 Interruptor accesorio/ Interruptor3 La carga parpadea o interruptor a presión no funciona incluso si la carga es superior a 40 W (-8S-DV solamente) Carga Tierra Neutro Diagrama de montaje NOTA: El atenuador debe ser instalado del lado de la carga del circuito Azul Negro Verde Tierra Cableado • Cables en cortocircuito. Asegúrese de que el terminal azul no esté conectado a tierra o en cortocircuito con otros cables. • Error en el cableado. Verifique el cableado para asegurarse de que cumpla con las instrucciones de instalación y con los diagramas de cableado. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga. La carga es menor que la carga mínima requerida • Asegúrese de que la carga conectada cumpla con los requerimientos de carga mínima para ese control. Vea la Especificaciones de carga. • Por -8S-DV, aumenta la carga para cumplir con los requisitos de carga mínima o uso -8ANS. Instale un condensador en paralelo. Vea Especificaciones de la carga. Azul1 Vivo Diagrama de cableado 5 Atenuador accesorio/ Atenuador3 c. Presione la placa sobre el adaptador y verifique que el control esté correctamente alineado. A cada control se le han quitado las aletas interiores Diagrama de cableado 1 Driver Lutron® Driver Lutron® de balasto/ de balasto/ LED LED Por favor, lea antes de instalar *C  ontrol de velocidad de ventilador: RRD-2ANF (120 V~ 50 / 60 Hz) * Atenuadores accesorios: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Driver Lutron® Driver Lutron® de balasto/ de balasto/ LED LED Español Instrucciones de instalación Maestro® RF estilo designer * Atenuador: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interruptor: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Disipación de calor del control de estado sólido • Los atenuadores / interruptores / controles de velocidad de ventilador de estado sólido disipan internamente cerca del 2% de la carga total conectada. Es normal que atenuadores / interruptores / controles de velocidad de ventilador se sientan tibios al tacto durante el funcionamiento. NOTA: Consulte la guía de configuración del sistema para sugerencias adicionales de solución de problemas. NOTA: El interruptor puede ser instalado en cualquier lugar del circuito. Vivo Negro Caja de empotrar Se incluye: 120–277 V~ 50/60 Hz Control Conectores de cable (1 o 5) El adaptador y la placa se venden por separado. Tornillos de montaje (2) Reemplazo de lámparas ADVERTENCIA – Peligro de choque eléctrico – Para cualquier otro procedimiento que no sea el reemplazo habitual de las lámparas se debe desconectar la alimentación desde el panel eléctrico principal. Trabajar con la alimentación CONECTADA puede resultar en lesiones personales graves o la muerte. Para su seguridad durante el reemplazo rutinario de lámparas, desconecte la alimentación del(los) artefacto(s) tirando hacia afuera el interruptor FASS™, a la posición APAGADO, en el atenuador / interruptor y también en todos los atenuadores / interruptores accesorios. Verde Negro Verde Negro Opcional Verde Carga Tierra Tierra Condensador paralelo2 Tierra Neutro 1 Cuando se usan controles en instalaciones con control desde un solo lugar, ajuste el terminal azul sin conectar ningún cable al mismo. NO conecte el terminal azul a ningún otro cable ni a tierra. 2E  l condensador paralelo debe ser instalado dentro del artefacto de carga o en una caja J separada. 3 Instalar solamente una (1) atenuador / interruptor / control de velocidad de ventilador por circuito. A un mismo atenuador / interruptor pueden conectarse hasta 9 atenuadores / interruptores / controles de velocidad de ventilador. El largo total del cable del terminal azul puede ser hasta 76 m (250 pies). 4 Los atenuadores / interruptores / controles de velocidad de ventilador con cable neutro deben conectarse del lado de la carga de una instalación desde múltiples lugares. Operación del atenuador / ventilador Operación del interruptor LED de estado (interruptor solamente) Indica el estado de luz; brilla suavemente como luz nocturna cuando la carga está apagada LEDs de estado (atenuador sólo) Indican el nivel de luz; brillan suavemente como luz nocturna cuando la carga está apagada Interruptor de presión Presione para encender o apagar Balancín de atenuación Presione para aumentar la intensidad de la luz o aumentar la velocidad Presione para atenuar o bajar la velocidad Atenuador muestra FASS™ Frente Accesible Servicio Interruptor Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA y ) son marcas registradas, y RadioRA 2, Compact SE y FASS son marcas de Lutron Electronics Co., Inc. NEC es una marca registrada de la National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc. Interruptor de presión Presione para encender o apagar FASS™ Frente Accesible Servicio Interruptor -RD-277 o -RS-277 sólo OR OFF ON Retorno a la configuración de fábrica NOTA: El retorno de un atenuador / interruptor / controle de velocidad de ventilador a su configuración de fábrica lo removerá del sistema y borrará toda su programación. Paso 1: P  ulse tres veces y mantenga el interruptor de presión de un control. NO suelte el botón después del tercer pulso. Paso 2 : M  antenga presionado el interruptor después del tercer pulso (durante 3 segundos aproximadamente) hasta que los LEDs del atenuador se enciendan y apaguen rápidamente en secuencia, o el LED del interruptor parpadee rápidamente. Paso 3 : S  uelte el interruptor e inmediatamente púlselo otras tres veces. Los LEDs del atenuador se encenderán y apagarán lentamente en secuencia. El LED del interruptor parpadeará lentamente. El control volvió ahora a su configuación de fábrica y deberá ser reprogramado dentro de un sistema. Garantía: Consulte la sección garantía que se incluye junto con el producto, o visite: www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf Spécifications de charge Commande -6D1 -6NA1 -10D1 Type de charge Charge min. Charge max. Inc. 50 W 600 W BTM2 50 W / VA 450 W / 600 VA Inc./ BTE2 5W 600 W BTM2 5 W / VA 450 W / 600 VA Inc. 50 W 1 000 W BTM 50 W / VA 800 W / 1 000 VA Inc. 10 W 1 000 W BTM2 10 W / VA 800 W / 1 000 VA Fluorescent/ DEL à trois (3) fils 0,05 A 6A 1 ballast 60 ballasts 2 -10ND1 -F6AN-DV3, 4, 5 6 -2ANF 7 -8ANS -8S-DV8, 9 -RD10 Ventilateur de 0,083 A plafond 2A Éclairage 10 W / VA 8A Moteur 0,08 A 1/4 HP 5,8 A Éclairage 40 W / VA 8A 0,4 A 1/10 HP 3A Moteur Voir gradateur -RS10 Voir interrupteur -RD-27711 11 -RS-277 Voir gradateur 8,3 A Voir interrupteur 1 Type de charge pour gradateur : -6D, -10D et -10ND sont conçus seulement pour des charges installées en permanence, incandescentes, magnétiques à basse tension ou tungstène halogène.  -6NA est conçue seulement pour des charges installées en permanence, incandescentes, électroniques à basse tension, magnétiques à basse tension ou tungstène halogène.  Ne pas installer de gradateurs pour la commande de prises standards ou d’appareils motorisés. Ne mélangez pas les types de charge incandescente, halogène, BTM ou BTE sur un gradateur. 2 Applications à basse tension : Utilisez les gradateurs -6D, -10D et -10ND uniquement sur des charges à transformateur basse tension ferro-magnétique. Ne pas utiliser sur un transformateur électronique (à semi-conducteur). Utiliser le gradateur -6NA sur des charges à contrôlables transformateur basse tension électronique (à semiconducteur) ou ferro-magnétique.  Le fonctionnement d’un circuit d’éclairage à basse tension ayant des ampoules hors d’usage ou non installées peut cause une surchauffe du transformateur et une défaillance prématurée. Lutron fait les recommandations suivantes : a. Ne pas utiliser les circuits à basse tension qui ne sont pas dotés de lampes en état de fonctionnement. b. Remplacer dès que possible les ampoules hors d’usage. c. Utiliser les transformateurs avec protection thermique ou enroulements primaires à fusible afin d’empêcher une défaillance causée par surintensité. 3 Type de charge pour gradateur fluorescent : Le gradateur -F6AN-DV est conçu pour utilisation avec ballasts de fluorescents ou pilotes de lampes à DEL raccordés en permanence sur un circuit 120 V~ ou 277 V~ à 3 fils. Utiliser seulement les appareils Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Ne PAS utiliser des ballasts ou pilotes différents avec ces produits. Ne pas installer pour le contrôle de prises de courant ou d’appareils motorisés. 4 Amplificateur de puissance / charge d’interfaces : -6NA, -10ND, -F6AN-DV, et -8ANS ne peut être utilisé pour contrôler amplificateur de puissance / charge d’interfaces. Pour connaître les types de amplificateur de puissance / charge d’interfaces compatibles voir Lutron P/N 369225. 5 Charge maximale : La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée soit le nombre de ballasts, selon le plus PETIT de ces deux nombres. 6  Application de ventilateur de plafond (-2ANF) : • S’utilise pour commander un seul ventilateur de plafond (moteur biphasé à condensateur permanent). • À l’aide de la chaîne à tirette, réglez la vitesse du ventilateur à son maximum*. • Ne pas utiliser pour commander les ventilateurs utilisant un moteur à pôle écran (p. ex. les ventilateurs de décharge d’air de salle de bain). • Ne pas utiliser pour commander un ventilateur qui a une commande de vitesse intégrée (ou qui est commandé à distance) à moins que la commande de vitesse soit retirée du ventilateur plafonnier*. • Ne pas raccorder à tout autre type d’appareil motorisé ou autre type de charge d’éclairage. • Ne pas utiliser pour commander une charge d’éclairage de plafonnier (luminaire). 7 Type de charge pour interrupteur -8ANS : La commande -8ANS est conçue pour une utilisation sur des charges installées en permanence, incandescentes, magnétiques à basse tension, electroniques à basse tension ou fluorescentes et charges motorisées jusqu’à 1/4 HP (5,8 A) fixes. 8 Type de charge pour interrupteur -8S-DV : Le interrupteur -8S-DV est conçu pour utilisation avec des charges motorisées, fluorescentes, incandescentes, à transformateur B.T. magnétique ou électronique raccordées en permanence sur une alimentation à 120 V~ ou avec charges fluorescentes ou à transformateur B.T. magnétique raccordées en permanence sur un circuit alimenté à 277 V~. 9  Condensateur shunt (inclus) : Certaines applications du interrupteur -8S-DV peuvent nécessiter l’installation d’un condensateur shunt. Ceci est principalement requis pour les types de charges sensibles aux courants de fuite (par ex. ballasts fluorescentes). Si la charge scintille, installer un condensateur shunt. Pour l’installation d’un condensateur shunt, voir le Schéma de câblage 4 ou 8. 10  Gradateur/interrupteur à distance à 120 V~ : Les gradateurs / interrupteurs à distance -RD et -RS sont conçus pour utilisation avec des gradateurs/interrupteurs à 120 V~. 11  Gradateur/interrupteur à distance à 277 V~ : Les gradateurs / interrupteurs à distance –RD-277 et –RS-277 sont conçus pour utilisation avec des gradateurs/interrupteurs à 277 V~. Ne PAS utiliser avec une charge motorisée. *Conditions typiques d’essai de consommation d’énergie : Gradateur / Comutateur / Commande de vitesse de ventilateur : 0,6 W (La charge est coupée et le mode éclairage nocturne est activé.) Gradateur / Interrupteur à distance : 0 W (La charge est coupée.) Commande -6D Gradateur Interrupteur Charge min. Charge max. Incand. 500 W 400 W BTM 400 W / 500 VA 300 W / 400 VA Incand./ BTE 500 W 400 W BTM 400 W / 500 VA 300 W / 400 VA -6NA -10D, -10ND Gradateur à distance Interrupteur à distance Commande de vitesse de ventilateur Notes importantes AVERTISSEMENT – Danger d’enfermement – Pour éviter les dangers d'enfermement, de graves blessures ou le décès de personne, ces commandes ne doivent pas être utilisées pour contrôler des équipements qui ne sont pas visibles à partir de tous les emplacements de commande ou pouvant créer des situations dangereuses ou des pièges si elles sont actionnées accidentellement. Les équipements qui ne doivent pas être contrôlés par ces commandes comprennent (mais sans s’y limiter) : les barrières motorisées, les portes de garage, les portes industrielles, les fours à micro-onde, les coussins chauffants etc. Il est de la responsabilité de l’installateur de s’assurer que l’équipement commandé est visible à partir de tous les emplacements de commande et que seuls des équipements appropriés sont connectés à ces contrôles. Le non respect de cette règle peut causer des blessures graves ou fatales. Codes : Installer conformément à tous les codes électriques locaux et nationaux. Mise à la terre : Dans les cas où le boîtier mural ne possède aucun “ dispositif de raccordement de fils de terre ”, le code “ National Electrical Code® ” (NEC®) 2011 américain permet l’installation de contrôles de remplacement si : 1) une plaque frontale non métallique et ininflammable est utilisée et fixée par des vis non métalliques ou 2) le circuit est protégé par un disjoncteur de fuite de terre (GFCI). Lors de l’installation d’un contrôleur selon l’une des ces méthodes, placez un capuchon sur le fil vert (ou retirezle) avant de monter le contrôleur dans le boîtier mural. Connexion au fil de neutre : Les gradateurs -6NA, -10ND, -F6AN-DV, -2ANF, et -8ANS requièrent une connexion au fil neutre du boîte murale où les gradateur / interrupteur / commande de ventilateur doivent être installés. Si un fil neutre n’est pas présent dans le boîte murale, contacter un électricien certifié pour modifier l’installation. Environnement : Température ambiante de fonctionnement : 0 ºC à 40 °C (32 °F à 104 °F) 0 à 90% d’humidité sans condensation. Usage à l’intérieur seulement. Espacement : Pour installer une commande au-dessus d’une autre, laisser un espace vertical d’au moins 114 mm (4 ½ po) entre elles. Plaques murales : Les plaques murales Claro® et Satin Colors® de Lutron® sont recommandées pour obtenir le meilleur assortiment de couleurs et une apparence esthétique. Ne pas peindre les commandes ni les plaques murales. Nettoyage : Pour nettoyer, essuyer à l’aide d’un linge propre et humide. NE PAS utiliser de nettoyants chimiques. Plaques murales : Lutron recommande les boîtes murales de 89 mm (3 ½ po) de profondeur pour faciliter l’installation. Plusieurs commandes peuvent être regroupées dans une boîte à assemblage multiple. Voir Tableau de déclassement. Gradateurs/interrupteurs à distance : Utiliser uniquement les gradateurs à distance (-RD/ -RD-277) et interrupteurs à distance (-RS/-RS-277) avec les interrupteurs/gradateurs. Un total de 9 -RD / -RD-277 ou -RS / -RS-277 peuvent être utilisés avec les gradateurs ou interrupteurs. Les interrupteurs mécaniques à trois ou quatre voies ne sont pas compatibles avec le système. Emplacement des dispositifs RF : Les gradateurs / interrupteurs et commandes de vitesse de ventilateurs RF doivent être placés à moins de 9 m (30 pi) d’un répétiteur de signal RF. Les gradateurs/ interrupteurs à distance ne doivent pas être obligatoirement à une distance spécifique d’un répétiteur. Pour les systèmes avec un répétiteur de signal RF, les gradateurs / interrupteurs / commandes de vitesse de ventilateurs RF ne peuvent pas être commandé par le système avant d’être programmés dans un système conformément au Guide de configuration de systèmes. Assistance technique : É.U. / Canada : 1.800.523.9466 | Mexique : 001-888-235-2910 Brésil: +55 (11) 3257-6745 (Lundi-Vendredi 8:30 to 17:30 BRT) | Autres pays : +1.610.282.3800 24 heures par jour, 7 jours par semaine www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012 Type de charge Incand. 800 W 650 W BTM 600 W / 800 VA 500 W / 650 VA 5A 3,5 A 50 ballasts 35 ballasts -F6AN-DV* Fluorescent/ DEL à 3 fils -2ANF Ventilateur de plafond -8ANS 2A 2A Éclairage 6,5 A 5A Moteur 1/4 HP 5,8 A 1/6 HP 4,4 A Éclairage 8A (duplex) 7A 7 A (triple) Moteur 1/10 HP 3A -8S-DV * La charge maximale pour le gradateur -F6AN-DV est soit la puissance de charge déclassée ou le nombre de ballasts, selon le plus PETIT des deux nombres. REMARQUE : Les commandes -8ANS, -RD277 and -RS-277 ont des ailettes qui doivent être enlevées avant de faire une installation à jumelage multiple. Les commandes -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS n’ont pas d’ailette à enlever pour les installations à jumelage multiple. Ne pas retirer les ailettes extérieures aux extrémités de l’alignement de contrôles multiples Le contrôle du milieu de l’unité a ses ailettes latérales enlevées des deux côtés Installation AVERTISSEMENT – Danger d’électrocution – Pour éviter les chocs électriques, Identifier et retirer le fusible ou verrouiller le disjoncteur en position Ouvert (OFF) avant de procéder. Effectuer le câblage sous tension peut entraîner des lésions corporelles graves, voire la mort. 1. Couper l’alimentation au niveau de la boîte à fusibles ou du disjoncteur. 2. Avant d’installer le(s) contrôles, contrôler la présence de tout court-circuit. Après avoir coupé l’alimentation, installer les interrupteurs mécaniques entre le fil sous tension et la charge et rétablir l’alimentation. Si les lumières ne s’allument pas ou qu’un disjoncteur se déclenche, vérifier et rendre le câblage conforme au schéma approprié et faire une nouvelle vérification. N’installer les contrôles qu’après avoir vérifié qu’il n’y a pas de courtcircuit. La garantie sera annulée si une unité de contrôle est mise sous tension dans un circuit comportant un court-circuit. 3. Câbler les contrôles selon un des moyens décrits ci-après : a. B  ornes de raccordement : Couper ou dénuder les fils de la boîte murale à la longueur indiquée à la jauge de dénudage à l’endos du contrôle. • Bornes à pression : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 1,5 mm2 (14 AWG). NE PAS utiliser de fil toronné ou torsadé. Insérer le conducteur jusqu’au fond de la borne. Pour dégager le fil, insérer un petit tournevis plat dans la fente sous la borne. et appliquer une pression en retirant le fil. OU Installation1 d’un seul avec neutre -6NA, -10ND, -2ANF et -8ANS (120 V~) Installation1 d’un seul sans neutre Interrupteur -6D, -10D (120 V~) Gradateur / interrupteur / commande de vitesse de ventilateur Interrupteur Laiton Sous tension Bleu 1 Noir b. C  apuchons de connexion : Préparation des fils. Pour les connexions avec capuchon, se conformer aux longueurs de dénudage recommandées pour les combinaisons de fils utilisés avec les capuchons fournis. REMARQUE : Les capuchons de connexion fournis s’utilisent avec des fils de cuivre seulement. Capuchon de connexion • Pour les fils de calibre 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG), enlever l’isolant sur 10 mm (3/8 po). Noir • U  tiliser pour raccorder un ou deux fils 1,5 mm (14 AWG) ou 2,5 mm2 (12 AWG) avec un fil de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG) Visser fermement le capuchon de connexion Vert Charge 120 V~ 50/60 Hz Charge Mise à la terre Schéma de câblage 3 Schéma de câblage 4 Installation1 d’un seul gradateur avec neutre -F6AN-DV (120/277 V~) Installation1 d’un seul sans neutre -8S-DV avec condensateur shunt en option2 (120-277 V~) Gradateur Laiton Sous Argenté tension Guide de dépannage Symptôme Cause probable et action suggérée Lumière / ventilateur ne répond pas à l’actionnement du bouton tactile du gradateur/interrupteur ou de la télécommande gradateur/ interrupteur Sans alimentation • Disjoncteur ouvert (OFF) ou déclenché. Vérifier la présence éventuelle de court-circuit. • L’interrupteur FASS™ est ouvert (position « OFF »). Vérifier le gradateur/ interrupteur et toutes les télécommandes gradateur/interrupteur. Voir Remplacement de tubes/ampoules. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge. Mise à la terre Neutre Noir Orange Blanc Bleu 1 Orange Vert Noir Orange Blanc Mise à la terre 2 Bleu 1 Argent Neutre 120/277 V~ 50/60 Hz • P  our les fils de calibre 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG), enlever l’isolant sur 11 mm (7/16 po). Laiton Sous tension Vert 120 V~ 50/60 Hz Noir Neutre Interrupteur Laiton Sous tension Noir La charge est en dessous de la charge minimale exigée • S’assurer que la charge connectée est conforme aux exigences minimales pour cette commande. Voir les Spécifications de charge. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge. Bleu 1 Optionnel Vert Charge 120-277 V~ 50/60 Hz Condensateur shunt2 Mise à la terre Ampoules brûlées ou absentes • Remplacer ou installer les ampoules. Neutre Schéma de câblage 5 Installation3 à emplacements multiples sans neutre Gradateur -6D, -10D with -RD (120 V~) Gradateur à distance / gradateur3 Laiton Sous tension Bleu Noir Gradateur à distance / gradateur3 Gradateur3 / gradateur à distance Laiton Laiton Noir Vert 120 V~ 50/60 Hz Bleu Vert Ampoules à diodes • Si des ampoules à diodes sont utilisées, les remplacer par des ampoules d’un autre type. Noir Réglage de ventilateur • Assurez-vous que le ventilateur est réglé, par sa chaîne à tirette, à sa vitesse maximale. REMARQUE : Le gradateur peut être installé à n’importe quel emplacement dans le circuit. Bleu Le contrôle de ventilateur n’est pas relié à un type de charge approprié • Assurez-vous que seulement un ventilateur à pales (moteur biphasé avec condensateur relié en permanence) de courant nominal de 2 A ou moins est relié au contrôle. • Assurez-vous qu’aucune charge d’éclairage (luminaires) n’est raccordée au contrôle. Vert Charge Mise à la terre Mise à la terre Mise à la terre Neutre Pour installation d’une unique et à multiples Voir schémas de câblage. 4. R  epousser tous les fils dans le boîtier mural et visser légèrement le contrôle au boîtier à l’aide des vis de montage fournies. Ne pas coincer les fils. 5. Attacher l’adaptateur de la plaque murale et la plaque murale Claro® ou Satin Colors® de Lutron®. Voir le Schéma d’assemblage. a. Installer l’adaptateur de la plaque murale sur le devant du/des contrôle(s). Les ailettes entre tous les contrôles adjacents sont enlevées Schéma de câblage 2 Schéma de câblage 1 • B  ornes à vis : N’utiliser qu’avec des conducteurs de cuivre massif de calibre 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG). NE PAS utiliser de fil multibrins ou toronné. Enrouler le conducteur sous la tête de la vis de la borne. Serrer au couple de 0,55 N•m (5 lb-po). b. Serrer les vis de montage du contrôle jusqu’à ce que l’adaptateur du boîtier mural soit à égalité du mur (ne pas trop serrer). c. Enclencher la plaque murale sur l’adaptateur et s’assurer que le contrôle est bien aligné. d. Si les contrôles sont mal alignés, desserrer les vis de montage en conséquence. 6. R  établir l’alimentation. Vérifier si le fonctionnement local est correct. Voir la feuille de Fonctionnement du gradateur / commande de vitesse de ventilateur ou Fonctionnement du interrupteur. Schéma d’assemblage Adaptateur Plaque de plaque murale Vis de murale montage Vis de des montage de contrôles l’adaptateur Schéma de câblage 6 Installation3 à emplacements multiples avec neutre4 -6NA, -10ND, -2ANF avec RD-RD, -8ANS avec RD-RS (120 V~) Gradateur à distance ou interrupteur à distance Laiton Sous tension Laiton 120 V~ 50/60 Hz Bleu Noir Vert Laiton Argent Bleu Noir Vert Mise à la terre REMARQUE : Le gradateur/interrupteur principal doit être raccordé à la charge. Gradateur / interrupteur / commande de vitesse de ventilateur Vert Mise à la terre Charge La charge scintillent ou bouton tactile ne fonctionne pas, même si la charge est supérieure à 40 W (-8S-DV seulement) Courant de fuite • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8. Les lumières s’allument et s’éteignent sans arrêt ou à l’actionnement du bouton tactile, les lumières s’allument et puis s’éteignent La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Pour le interrupteur -8S-DV, ajouter un condensateur shunt. Voir le Schéma de câblage 4 ou 8. • Pour -8S-DV, augmenter la charge au-dessus du minimum requis ou utiliser -8ANS. Installer un condensateur shunt. Voir Spécifications de charge. La charge scintillent (-8S-DV seulement) La charge est de puissance inférieure au minimum requis • Augmenter la charge au-dessus du minimum requis pour ce contrôle. Voir Spécifications de charge. • Installer un condensateur shunt. Voir le Schéma de câblage 4 ou 8. Lumières ne s’allument pas ON / OFF à partir d’un clavier Programmation inadéquate • Programmer conformément au Guide de configuration du système. Mise à la terre Neutre Schéma de câblage 7 Installation3 de gradateurs à emplacements multiples avec neutre4 Gradateur -F6AN-DV avec gradateur à distance -RD ou -RD-277 (120/277 V~) Gradateur à distance Gradateur à distance Laiton/ Laiton/ Rouge Sous Rouge tension Noir 120/277 V~ 50/60 Hz Bleu Noir Bleu REMARQUE : Le gradateur principal doit être raccordé à la charge. Gradateur Laiton Argenté Vert Mise à la terre Noir Vert Mise à la terre Bleu Orange Noir Orange Blanc Vert Mise à la terre Noir Orange Blanc Neutre Hors de la portée RF • Rapprocher à moins de 9 m (30 pi) d’un répétiteur de signal RF. Câblage • Fils court-circuités. S’assurer que la borne bleue n’est pas mise à la terre ou court-circuitée à d’autres fils. • Erreur de câblage. S’assurer que le câblage est conforme aux directives d’installation et aux schémas de câblage. Schéma de câblage 8 Installation3 à emplacements multiples sans neutre Interrupteur -8S-DV avec interrupteur à distance -RS ou -RS-277 et condensateur shunt en option2 (120-277 V~) Interrupteur à distance / interrupteur3 Laiton/ Rouge Sous tension Noir 120-277 V~ 50/60 Hz Boîtier mural Inclus : Bleu Noir Gradateur à distance ou interrupteur à distance Ballast/pilote de lampe à diodes Lutron® Pour le Guide de configuration du système et outils requis, consulter le site www.lutron.com/radiora2 Dans les installations à jumelage multiple, plusieurs commandes sont regroupées horizontalement dans un boîtier mural à jumelage multiple. Lorsque des commandes sont regroupées dans un boîtier mural, le déclassement est requis. Ceci ne s’applique pas aux commandedes de vitesse des ventilateurs et gradateurs/ interrupteurs à distance. Tableau de déclassement Ballast/pilote de lampe à diodes Lutron® * Interrupteurs à distance : RD-RS (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) Ballast/pilote de lampe à diodes Lutron® Installations à jumelage multiple Veuillez lire avant l’installation *C  ommande de vitesse de ventilateur : RRD-2ANF (120 V~ 50 / 60 Hz) * Gradateurs à distance : RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Ballast/pilote de lampe à diodes Lutron® Français Directives d’installation Gradateurs style décorateur Maestro® RF * Gradateur : RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interrupteur : RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) Bleu Vert Interrupteur à distance / interrupteur3 Interrupteur3 / interrupteur à distance Laiton/ Rouge Laiton/ Rouge Noir Bleu Vert Noir Bleu Mise à la terre Dissipation de la commande à semi-conducteurs • Les gradateurs/interrupteurs /commande de vitesse de ventilateur à semi-conducteurs dissipent à l’intérieur environ 2 % de la charge totale raccordée. Il est normal qu’ils soient chauds au toucher lorsqu’ils sont en service. REMARQUE : Pour des suggestions additionnelles de dépistage de défauts, se référer au guide de configuration. Optionnel Vert Charge Mise à la terre La plaque murale est chaude REMARQUE : Le interrupteur peut être installé à n’importe quel emplacement dans le circuit. Mise à la terre Condensateur shunt2 Neutre Commande Capuchons de connexion (1 ou 5) Vis de montage (2) Adaptateur de plaque murale et plaque murale vendus séparément. Remplacement de tubes/ ampoules AVERTISSEMENT – Danger d’électrocution – Pour toute autre procédure que le simple remplacement des tubes/ampoules, l’alimentation doit être coupée au panneau de distribution. Effectuer tout travail avec le système sous tension peut entraîner des lésions corporelles graves, voire la mort. Pour remplacer les tubes/ampoules sans danger, couper l’alimentation des appareils d’éclairage en plaçant l’interrupteur FASS™ du gradateur/interrupteur et de tous les gradateurs/interrupteurs à distance en position OFF. 1 Pour les installations à un seul emplacement de commande, serrer la borne bleue sans y relier de fil. NE connecter aucun des fils, ou fil de mise à la terre à la borne bleue. 2 Le condensateur shunt doit être installé à l’intérieur du boîtier de l’appareil d’éclairage ou dans un boîtier de jonction séparé. 3 Installer un (1) seulement gradateur/interrupteur / commandes de vitesse de ventilateurs par circuit. Un circuit de gradateur/ interrupteur / commande de vitesse de ventilateur peut comprendre jusqu’à 9 contrôles gradateur/interrupteur / commande de vitesse de ventilateur à distance. La longueur permise du fil bleu est de 76 m (250 pi). 4 Les gradateurs / interrupteurs / commandes de vitesse de ventilateurs avec fil neutre doivent être connectés du côté charge d’une installation à emplacement multiple. Fonctionnement du gradateur / commande de vitesse de ventilateur Gradateur montré Fonctionnement du interrupteur Voyants d’état (-F6AN-DV seulement) Indique le niveau d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée Bouton touche Toucher pour allumer/éteindre Voyant d’état (-8S-DV seulement) Indique l’état de l’appareil d’éclairage et émet une lueur discrète de veilleuse lorsque la charge est coupée Bouton d’actionnement à bascule du gradateur Appuyer pour augmenter l’intensité d’éclairage ou augmenter la vitesse Appuyer pour diminuer l’intensité d’éclairage ou diminuer la vitesse Bouton touche Toucher pour allumer/éteindre FASS™ Interrupteur de Service à Accès Frontal FASS™ Interrupteur de Service à Accès Frontal -RD-277 ou -RS-277 seulement OR OFF ON Rappel des réglages d’usine des gradateurs/interrupteurs REMARQUE : Le rappel du gradateur / interrupteur /commandes de vitesse de ventilateurs à ses réglages d’usine le retirera du système et effacera toute sa programmation. Étape 1 : T  aper trois fois du doigt sur le bouton tactile d’un contrôle et garder le doigt appuyé sur le bouton après la troisième tape. Étape 2 : G  arder le bouton appuyé durant environ 3 secondes, jusqu’à ce que les voyants du gradateur débutent une séquence d’illumination de va-et-vient rapide ou que le voyant DEL du interrupteur se mette à clignoter rapidement Étape 3 : R  elâcher le bouton et refaire immédiatement trois tapes rapides sur le bouton. Les voyants du gradateur débuteront une séquence d’illumination de va-et-vient lente. Le voyant DEL du interrupteur clignotera lentement. Le contrôle est alors remis à ses réglages d’usine et doit être reprogrammé dans le système. Garantie : voir la garantie incluse avec le produit ou visitez : www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, et ) sont des marques de commerce déposées et RadioRA 2, Compact SE et FASS sont des marques de commerce de Lutron Electronics Co., Inc. NEC est une marque de commerce déposée de National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Electronics Co., Inc. Em instalações multigrupos, vários controles são reunidos horizontalmente em uma mesma caixa de embutir. Ao combinar controles em uma caixa de embutir, é preciso reduzir a carga. Isso não é necessário para controles de velocidade de ventilador e dimmers / interruptores remotos. Tabela de redução de carga Tipo de carga Carga mín. Carga máx. -6D1 -6NA1 -10D1 -10ND1 Incand. 50 W 600 W BTM2 50 W / VA 450 W / 600 VA Incand. / BTE2 5W 600 W BTM2 5 W / VA 450 W / 600 VA Incand. 50 W 1 000 W BTM2 50 W / VA 800 W / 1 000 VA Incand. 10 W 1 000 W 10 W / VA 800 W / 1 000 VA 0,05 A 6A 2 BTM -F6AN-DV Fluorecente / LED de 3 fios 1 balastro 60 balastros -2ANF6 Ventilador de teto 0,083 A 2A Iluminação 10 W / VA 8A Motor 0,08 A 1/4 HP 5,8 A Iluminação 40 W / VA 8A Motor 0,4 A 1/10 HP 3A 3, 4, 5 -8ANS7 -8S-DV8, 9 -RD10 Consulte dimmer -RS10 Consulte interruptor 11 Consulte dimmer 11 Consulte interruptor -RD-277 -RS-277 8,3 A 1 Tipo de carga de dimmer: Os controles -6D, -10D e -10ND só devem ser utilizados com cargas incandescentes, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  O controle -6NA só deve ser utilizado com cargas incandescentes, eletrônicos de baixa tensão, magnéticas de baixa tensão ou de tungstênio-halogênio instaladas permanentemente.  Não instale dimmers para comandar tomadas ou aparelhos motorizados. Não é permitido misturar tipos de carga incandescente, halogênio, BTM ou BTE em um dimmer. 2 Aplicações de baixa tensão: Use os modelos -6D, -10D e -10ND somente com transformadores magnéticos (núcleo e bobina) de baixa tensão. Não devem ser utilizados com transformadores eletrônicos (transistorizados) de baixa tensão.  Use o modelo -6NA com dimerizáveis transformadores eletrônicos (transistorizados) ou magnéticos (núcleo e bobina) de baixa tensão.  El funcionamiento de un circuito de bajo voltaje sin lámparas o con lámparas que no funcionan puede resultar en el sobrecalentamiento del transformador y fallas prematuras. Lutron recomienda firmemente lo siguiente: a. Não use circuitos de baixa tensão sem lâmpadas boas. b. Substitua lâmpadas as queimadas o mais rápido possível. c. Use transformadores com proteção térmica ou enrolamentos primários com fusível para evitar falhas devido a sobrecorrentes. 3 Dimmer de carga tipo fluorescente: -F6AN-DV foi projetado para uso com controles de balastros fluorescentes ou comandos de LEDs com voltagem de linha de 120 V~ ou 227 V~ de três cabos instalados permanentemente. Use somente com Hi-lume®, Hi-lume® 3D, Hi-lume® A-Series, Compact SE™, Eco-10®, ou EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). NÃO use com qualquer outro balastrobalastro ou comando. Não instale para controlar receptáculos ou aplicações operadas por motor. 4 Amplificador de potência – interfaces de carga: -6NA, -10ND, -F6AN-DV, e -8ANS pode ser usado para controlar amplificador de potência – interfaces de carga. Para obter uma lista de amplificador de potência – interfaces de carga compatíveis consulte Lutron P/N 369225. 5 Carga máxima: A caga máxima para o -F6AN-DV é a carga reduzida ou o número de balastros, o que for MENOR. 6 Aplicação de ventilador de teto (-2ANF): • Usar para controlar um ventilador de teto do tipo com pá (condensador permanente)*. • Usar a corrente de tração do ventilador de teto para programar sua velocidade para a mais alta*. • Não usar para controlar ventiladores que usam motores (i.e. ventiladores de exaustão de banheiro)*. • Não usar para controlar ventiladores que têm controles de velocidade integrados (i.e. ventiladores que têm controle remoto), a menos que o controle integrado tenha sido removido do ventilador de teto*. • Não conectar a nenhum outro equipamento operado por motor ou a qualquer outro tipo de carga de iluminação. • Não usar para controlar uma carga de iluminação de ventilador (i.e. kit de luz). 7 Tipo de carga do interruptor -8ANS: -8ANS é um tipo projetados para uso com todas as cargas incandescentes, magnéticas de baixa tensão, eletrônicos de baixa tensão ou de fluorescentes instaladas permanentemente e com cargas de motor de até 1/4 HP (5,8 A). 8 Tipo de carga do interruptor -8S-DV: -8S-DV foi projetado para uso com cargas incandescentes permanentemente instaladas de 120 V~, baixa voltagem magnética, baixa voltagem eletrônica ou cargas de motores; ou cargas fluorescentes ou baixa voltagem magnética de 277 V~. 9 Condensador Shunt (incluído): Algumas instalações do -8S-DV podem exigir o uso de um condensador shunt. Isto é necessário para tipos de cargas sensíveis à corrente de fuga (ou seja, balastros fluorescentes). Se carga tremula, instale um condensador shunt. Para a instalação do condensador shunt, consulte o Esquema de ligações elétricas 4 ou 8. 10  Dimmer / interruptor remoto 120 V~: -RD e -RS foram projetados para uso com dimmers / interruptores 120 V~. 11  Dimmer / interruptor remoto 277 V~: -RD-277 e -RS-277 foram projetados para uso com dimmers/ interruptores 277 V~. NÃO use com cargas de motor. *Condições de teste de consumo normal de energia: Dimmer / Switch / Controle de velocidade de ventilador: 0,6 W (Carga desligada, modo luz noturna habilitado.) Dimmer / Interruptor remoto: 0 W (Carga desligada.) -6D Dimmer Interruptor -6NA -10D, -10ND Dimmer remoto Interruptour remoto Controle de velocidade de ventilador Notas importantes AVISO – Perigo de imobilização – Para evitar o risco de imobilização, ferimentos graves ou morte, estes controles não devem ser usados para controlar equipamentos que não estão visíveis a partir de todos os locais de controle ou que podem criar situações perigosas, como imobilização, caso seja operado acidentalmente. Exemplos de equipamentos que não devem ser operados por estes controles incluem (mas não se limitam a) portões motorizados, portões de garagem, portões industriais, fornos de microondas, etc. É de responsabilidade de quem instala garantir que o equipamento que está sendo controlado esteja visível de cada local de controle e que somente equipamentos adequados sejam conectados a estes controles. Proceder de maneira contrária poderá causar morte ou ferimentos graves. Códigos: Instale de acordo com os códigos elétricos locais e nacionais. Aterramento: Se não houver uma “forma de aterramento” dentro da caixa de embutir, o Código Nacional de Eletricidade de 2011 (2011 National Electrical Code ® - NEC ®) permite que um controle seja instalado como um substituto, se 1) um espelho não metálico e não combustível for usado com parafusos não metálicos ou 2) o circuito for protegido por um interruptor diferencial por falha no aterramento (GFCI). Ao instalar um controle de acordo com esses métodos, tampe ou remova o fio verde antes de parafusar o controle na caixa de embutir. Neutro: Os modelos -6NA, -10ND, -F6AN-DV, -2ANF, e -8ANS exigem um condutor neutro na caixa de embutir, onde devem ser instalados o dimmer/ interruptor/controles de ventilador. Se não houver um condutor neutro na caixa de embutir, procure um eletricista autorizado para instalá-lo. Ambiente: Temperatura ambiente de trabalho: 0 °C a 40 °C (32 °F to 104 °F), 0% a 90% de umidade, sem condensação. Uso somente interior. Espaçamento: Se for instalar um controle sobre o outro, mantenha um espaço vertical entre eles de pelo menos 114 mm (4 ½ in). Espelhos: os modelos Lutron® Claro® e Satin Colors® são recomendados pela variedade de cores e pelo design. Não pinte os controles ou espelhos. Limpeza: Para limpar, passe um pano limpo úmido. NÃO use qualquer solução química de limpeza. Caixa de embutir: A Lutron recomenda o uso de caixas com 89 mm (3 ½ in) de profundidade para facilitar a instalação. É possível instalar vários controles em uma mesma caixa de instalação embutida. Consulte o Tabela de redução de carga. Dimmers / interruptores remotos: Use somente dimmers remotos (-RD / -RD-277) e interruptores remotos (-RS / -RS-277) com dimmers / interruptores. Podem ser usados até 9 -RD / -RD-277 or -RS / -RS-277 com dimmers ou interruptores. Interruptores mecânicos de 3 ou 4 vias não funcionarão. Localização dos dispositivos de RF: Os dimmers / interruptores e controles de velocidade de ventilador de RF devem estar a uma distância máxima de 9 m (30 pés) de um repetidor de sinal de RF. Os interruptores / dimmers remotos não precisam estar dentro de limites específicos em relação a um repetidor. Para sistemas com repetidor de sinal de RF, os dimmers / interruptores / controles de velocidade de ventilador de RF não podem ser controlados pelo sistema enquanto não estiverem programados de acordo com o Guia de configuração do sistema. Assistência técnica: Brasil: +55 (11) 3257-6745 (Segunda-feira–Sexta-feira 8:30 to 17:30 BRT) E.U.A. / Canadá: 1.800.523.9466 | México: +1.888.235.2910 | Outros países: +1.610.282.3800 24 horas por dia, 7 dias por semana www.lutron.com Lutron Electronics Co., Inc. 7200 Suter Road | Coopersburg, PA 18036-1299 P/N 044-319 Rev. B 09 / 2012 -8ANS Carga Esquema de ligações 3 Instalação1 em um único local com neutro -F6AN-DV (120/277 V~) 500 W BTM 400 W / 500 VA 300 W / 400 VA Incand. 800 W 650 W BTM 600 W / 800 VA 500 W / 650 VA 5A 3,5 A 50 balastros 35 balastros Ventilador de teto 2A 2A Iluminação 6,5 A 5A Motor 1/4 HP 5,8 A 1/6 HP 4,4 A Iluminação 8A (2-grupos) 7A (3-grupos) 7A Motor 1/10 HP 3A Verde 120 V~ 50/60 Hz Terra Carga Guia para resolução de problemas Sintoma Causa provável e ação As luz ou ventilador não ACENDEM/APAGAM quando a chave seletora no dimmer / interruptor / controle de velocidade de ventilador ou dimmer / interruptor remoto é pressionada Não há alimentação. • Disjuntor DESLIGADO ou aberto. Verifique se há curtos-circuitos. • FASS™ está na posição OFF. Mude FASS™ para a posição ON. Verifique o dimmer / interruptor / controle de velocidade de ventilador, bem como todos os dimmers / interruptores remotos Consulte Substituição da lâmpada. Terra Neutro Neutro Esquema de ligações 4 Instalação1 em um único local sem neutro -8S-DV com condensador shunt opcional2 (120-277 V~) • R  emova 10 mm (3/8 pol) de isolante do fio 1,5 mm2 (14 AWG) ou do fio 2,5 mm2 (12 AWG). • R  emova 11 mm (7/16 pol) de isolante do fio 0,75 mm2 (18 AWG) ou do fio 1,0 mm2 (16 AWG). • U  se para unir um ou dois cabos 1,5 mm2 (14 AWG) ou 2,5 mm2 (12 AWG) com um cabo 0,75 mm2 (18 AWG) ou 1,0 mm2 (16 AWG). Preto Laranja Branco Azul1 Latão Prata Vivo Laranja Preto Verde 120/277 V~ 50/60 Hz Interruptor Latão Azul1 Vivo Preto Preto Laranja Branco Terra Neutro Lâmpadas estão queimadas ou não estão instaladas • Substitua ou instale as lâmpadas. Opcional Verde Condensador Shunt 2 Carga 120-277 V~ 50/60 Hz Lâmpadas de diodo • Se estiverem sendo usadas lâmpadas de diodo, substitua-as por lâmpadas sem diodo Terra Neutro Programação do ventilador • Verifique se o ventilador está programado para sua mais alta velocidade usando a corrente de tração. Esquema de ligações 5 Instalação3 em vários locais sem neutro -6D, -10D with -RD (120 V~) Dimmer remoto / dimmer 3 Gire com firmeza o conector de fiação Dimmer remoto / dimmer 3 Latão Azul Latão Tipo de carga errada no controle de velocidade de ventilador • Confirme se apenas um único ventilador de pás giratórias de teto (motor com condensador permanente) classificado em 2 A ou menos está ligado ao controle. • Verifique se nenhuma carga de iluminação (i.e. kit de luz) está conectado ao controle. Dimmer 3 / dimmer remoto Latão Azul Azul NOTA: O dimmer pode ser instalado em qualquer lugar do circuito. Vivo Preto número de balastros, o que for MENOR. NOTA: -8ANS, -RD-277 and -RS-277 possuem aletas que precisam ser removidas para instalações multigrupos. -6D, -6NA, -10D, -10ND, -F6AN-DV, -2ANF, -8S-DV, -RD and -RS não possuem abas que precisam ser removidas. Não remova as abas externas nos controles na extremidade do grupo. 4. C  oloque os cabos de volta na caixa de embutir e parafuse, sem apertar, o controle na caixa usando os parafusos fornecidos. Não amasse os cabos. b. Aperte os parafusos de montagem do controle até que adaptador do espelho fique rente à parede (não aperte demais). c. Encaixe o espelho no adaptador e verifique se o controle está alinhado corretamente. d. Se os controles estiverem desalinhados, afrouxe os parafusos de montagem apropriadamente O controle no meio do grupo está com todas as abas removidas Instalação ATENÇÃO – Risco de choques – Para evitar o risco de choques elétricos, localize e remova o fusível ou trave o disjuntor na posição OFF (desligado) antes de prosseguir. Fazer instalação com a chave geral ligada pode resultar em lesões graves ou fatais. 1. DESLIGUE a alimentação na caixa de fusível ou no disjuntor. 2. Verifique a instalação quanto a curtos-circuitos antes de instalar o(s) controle(s). Com a alimentação DELSIGADA, instale interruptores mecânicos padrão entre quente e a carga. Restabeleça a alimentação. Se as lâmpadas e ventalidores não funcionar ou o disjuntor for desarmado, verifique a fiação. Corrija a fiação e verifique novamente. Instale os controles somente quando não houver curtos-circuitos. A garantia é invalidada se o controle foi acionado (ON) havendo um curto-circuito. 3. Conecte os cabos de acordo com uma das opções abaixo: a. T  erminais: Apare ou retire o isolamento dos fios da caixa de embutir no comprimento indicado pelo medidor de corte, na parte posterior do controle. • Terminais a pressão: Use apenas com o fio 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Insira os cabos completamente. Para soltar um cabo, insira uma chave de fenda pequena na ranhura abaixo do terminal a pressão. Pressione a chave de fenda enquanto puxa o cabo para fora. OU 6. R  estabeleça a alimentação. Verifique se a operação local está correta. Consulte a Operação do dimmer / controle de velocidade de ventilador ou Operação do interruptor. Preto Verde Verde Carga Terra Terra Terra Neutro Esquema de ligações 6 Instalação3 em vários locais com neutro4 -6NA e -10ND, -2ANF com RD-RD, -8ANS com RD-RS (120 V~) 5. Prenda o adaptador de espelho e o espelho Claro® ou Satin Colors® da Lutron®. Consulte o Diagrama de montagem. a. Instale o adaptador do espelho na frente do(s) controle(s). Preto Verde 120 V~ 50/60 Hz Instalação em um só local ou vários locais consulte os esquema de ligações. Dimmer remoto ou interruptor remoto Dimmer remoto ou interruptor remoto Latão Latão Azul Preto Verde 120 V~ 50/60 Hz NOTA: O dimmer deve ser instalado no lado da carga do circuito. Azul Latão Prata Preto Verde Terra A carga tremula ou chave seletora não funciona, mesmo se a carga for superior a 40 W (somente -8S-DV) Corrente de fuga • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8. A luz acende e apaga continuamente ou a luz acende (ON) quando a chave seletora é pressionada, apagando em seguida (OFF) A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt com o -8S-DV. Consulte o Esquema de ligações elétricas 4 ou 8. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga. A carga tremula (somente -8S-DV) A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima de carga. Consulte as Especificações de carga. • Instale um condensador shunt. Consulte o Esquema de ligações elétricas 4 ou 8. As luzes / ventiladores não acendem/apagam a partir de um teclado Programação incorreta • Programe de acordo com o Guia de configuração do sistema. Dimmer / Interruptor / Controle de velocidade de ventilador Azul Vivo Preto Verde Terra Carga Terra Neutro Esquema de ligações 7 Instalação3 do interruptor em vários locais com neutro -F6AN-DV com -RD ou -RD-277 (120/277 V~) Dimmer remoto Latão/ Vermelho Dimmer remoto Latão/ Vermelho Azul Latão Prata Preto Preto Azul Laranja Preto Laranja Branco Preto Laranja Branco Preto Verde Verde Verde Terra Terra Terra Neutro O espelho está quente Instalação3 do interruptor em vários locais sem neutro -8S-DV com -RS ou -RS-277 e condensador shunt opcional2 (120-277 V~) Diagrama de montagem Adaptador Espelho do espelho Parafusos de instalação Parafusos de montagem do do controle adaptador Latão/ Vermelho Vivo Preto 120-277 V~ 50/60 Hz Latão/ Vermelho Azul Verde Preto Azul Verde Latão/ Vermelho Preto Azul NOTA: O interruptor pode ser instalado em qualquer lugar do circuito. Terra (01) 07898525200097 Condensador Shunt 2 Terra 1 Ao usar controles em instalações de único local, aperte o terminal azul sem nenhum fio conectado. NÃO conecte o terminal Controle Conectores de cabos (1 ou 5) Adaptador do espelho e espelho vendidos separadamente. Parafusos de instalação (2) AVISO – Perigo de choque – No caso de qualquer procedimento que não seja a troca rotineira de lâmpadas, o painel elétrico principal deverá estar desconectado da rede elétrica. Trabalhar com a rede ligada pode resultar em lesões graves ou fatais. Para sua segurança no caso de troca rotineira de lâmpadas, desligue a(s) luminária(s) movendo o interruptor FASS™ do dimmer / interruptor e de todos os interruptores / dimmers remotos para a posição OFF (desligado). Modelo: RRD-6D 0839-11-6852 3283-10-0905 (01) 07898525200219 Modelo: RRD-8ANS 0839-11-6852 azul a nenhum outro fio nem ao terra. 2O  condensador shunt deve ser instalado no lado da luminária de carga ou em uma caixa J separada. 3 Instalação apenas um (1) dimmer / interruptor/ controle de velocidade de ventilador por circuito. Podem ser conectados no dimmer / interruptor / controle de velocidade de ventilador até 9 dimmers / interruptores remotos. O comprimento total do cabo do terminal azul pode chegar a 76 m (250 pés). 4 Os dimmers / interruptores / controles de velocidade de ventilador de fio neutro devem ser conectados no lado da carga da Substituição de lâmpada 0839-11-6852 0145-11-0905 Modelo: RRD-10ND Este equipamento opera em caráter (01) secundário, 07898525200110 Modelo: RRD-F6AN-DV isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estaçoes do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. Opcional Verde Carga Terra Modelo: MRF2-3BRL-L Interruptor 3 / Interruptor remoto Neutro Caixa de embutir Incluído: Interruptor remoto / interruptor 3 Dissipação de controle de estado sólido • Os dimmers / interruptores / controles de velocidade de ventiladores de estado sólido dissipam internamente cerca de 2% da carga total conectada. É normal que os dimmers / interruptores / controles de velocidade de ventiladores fiquem quentes durante o funcionamento. NOTA: Consulteo guia de configuração do sistema para outras sugestões de solução de problemas. Esquema de ligações 8 Interruptor remoto / interruptor 3 Fora da faixa de RF • Reposicione para estar dentro de um raio de 9 m (30 pés) de um repetidor de sinais de RF. Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão. NOTA: O dimmer deve ser instalado no lado da carga do circuito. Dimmer Azul Vivo 120/277 V~ 50/60 Hz Fiação • Cabos em curto. Verifique se o terminal azul não está conectado ao terra ou em curto com algum outro cabo. • Erro na fiação. Verifique se a fiação está de acordo com as instruções de instalação e os diagramas de conexão. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga. A carga é inferior ao mínimo exigido. • Verifique se as cargas conectadas atendem à exigência mínima do controle. Consulte o Especificações de carga. • Para -8S-DV, Verifique se as cargas conectadas atendem à exigência mínima de carga ou usar -8ANS. Consulte as Especificações de carga. Dimmer * A caga máxima para o -F6AN-DV é a carga reduzida ou o Cada controle teve as abas internas removidas 120 V~ 50/60 Hz Azul1 Preto NOTA: Os conectores de cabo fornecidos são adequados somente para cabos de cobre. 400 W 400 W / 500 VA Incand./ BTE Latão Prata Vivo Verde Conector de cabo: 500 W BTM -8S-DV Preto 400 W Incand. -2ANF Azul1 Vivo 300 W / 400 VA Meio do agrupamento Fluorescente / LED de 3 fios. Latão Dimmer / Interruptor / Controle de velocidade de ventilador b. C  onectores de cabos: Prepare os cabos. Ao fazer conexões de cabos, siga o comprimento recomendado de desencape e as combinações para os conectores de cabo fornecidos Extremo final do agrupamento -F6AN-DV* Interruptor Comando da Lutron® do balastro/LED Controle Tipo de carga Instalação1 em um único local com neutro -6NA, -10ND, -2ANF e -8ANS (120 V~) Instalação1 em um único local sem neutro -6D, -10D (120 V~) Comando da Lutron® do balastro/LED Controle Especificações de carga • T  erminais parafusados: Use apenas com o fio 2,5 mm2 (12 AWG) ou 1,5 mm2 (14 AWG) de cobre sólido. NÃO use cabos trançados ou torcidos. Enrole o cabo em volta do terminal parafusado. Aperte bem com 0,55 N•m (5 pol-lb). Comando da Lutron® do balastro/LED Para o Guia de configuração do sistema e ferramentas, visite: www.lutron.com/radiora2 Esquema de ligações 2 Esquema de ligações 1 Instalações múltiplas Por favor, leia antes de instalar *C  ontrole de velocidade de ventilador: * Interruptores remotos: RD-RS (120 V~ 50 / 60 Hz) RRD-2ANF (120 V~ 50 / 60 Hz) RD-RS-277 (277 V~ 50 / 60 Hz) * Dimmers remotos: RD-RD (120 V~ 50 / 60 Hz) RD-RD-277 (277 V~ 50 / 60 Hz) Comando da Lutron® do balastro/LED Português Instruções de instalação Tipo designer RF Maestro® * Dimmer: RRD-6D, -6NA, -10D, -10ND (120 V~ 50 / 60 Hz) RRD-F6AN-DV (120/277 V~ 50 / 60 Hz) * Interruptor: RRD-8ANS (120 V~ 50 / 60 Hz) RRD-8S-DV (120-277 V~ 50 / 60 Hz) instalação em vários locais. Operação do dimmer / controle de velocidade de ventilador LEDs de status (somente -F6AN-DV) Indica a intensidade da luz; tem um brilho leve, como uma iluminação noturna, quando a carga está desligada LED de status (somente -8S-DV) Indica o status da luz; tem um brilho suave, como uma iluminação noturna, quando a carga está desligada Chave seletora Toque para ligar/desligar Chave seletora Toque para ligar/desligar Controle de atenuação Pressione para aumentar a intensidade de luz ou para aumentar a velocidade Pressione para reduzir a intensidade de luz ou para reduzir a velocidade de ventilador Dimmer mostrado FASS™ Frente Acessível Serviço Interruptor Lutron, Claro, Satin Colors, Maestro, Hi-lume, Ecosystem, Eco-10, RadioRA, e ) são marcas registradas e RadioRA 2, Compact SE e FASS são marcas registradass da Lutron Electronics Co., Inc. NEC é marca registrada da National Fire Protection Association, Quincy, Massachusetts. ©2012 Lutron Brasil Ltda. (01) 07898525200073 Modelo: RRD-10D 0839-11-6852 (01) 07898525200103 2854-10-0905 Modelo: RRD-8S-DV Operação do interruptor FASS™ Frente Acessível Serviço Interruptor -RD-277 ou -RS-277 apenas OR OFF ON (01) 07898525200080 (01) 07898525200189 Restauração dos dimmers/interruptores para a configuração de fábrica NOTA: A restauração de um dimmer / interruptor / control de velocidade de ventiladore para a configuração de fábrica o removerá do sistema e apagará toda a programação Passo 1: T  oque três vezes na chave seletora de um controle. NÃO solte após o terceiro toque. Passo 2: M  antenha a chave seletora pressionada após o terceiro toque (por aproximadamente 3 segundos) até que os LEDs no dimmer comecem a piscar em sequência para cima e para baixo rapidamente ou o LED no interruptor pisque rapidamente. Passo 3: S  olte a chave seletora e, imediatamente, pressione-a três vezes novamente. Os LEDs no dimmer se deslocarão para cima e para baixo lentamente. O LED no interruptor piscará lentamente. O controle agora retornou à configuração de fábrica e precisa ser programado para um sistema. Garantia: Consulte a garantia que acompanha o produto ou visite: www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Lutron Electronics RadioRA 2 Guía de instalación

Tipo
Guía de instalación