GAF 0448737 Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

INSTALLATION INSTRUCTIONS
·
INSTRUCCIONES DE INSTALACIÓN
·
INSTRUCTIONS D’INSTALLATION
1.
Quality You Can Trust…From
North America’s Largest Roofing Manufacturer!
¡
Calidad En La Que Usted Puede Confiar...Del
Fabricante De Techos Más Grande De Norteamérica!
Une Qualité À Laquelle Vous Pouvez Vous Fier...
Du Plus Gros Fabricant De Toitures En Amérique Du Nord!
MC
GENERAL INSTRUCTIONS
• SAFETY DATA SHEETS: When using GAF products, e.g., shingles, underlayments, plastic cement, etc., please refer to the applicable SDS.
The most current versions are available at gaf.com. GAF does not provide safety data sheets or installation instructions for
products not manufactured by GAF. Please consult the material manufacturer for their SDS and installation instructions where appropriate.
ROOF DECKS: Use minimum 3/8" (10mm) plywood or OSB decking as recommended by APA-The Engineered Wood Assn. Wood decks must
be well-seasoned and supported having a maximum 1/8" (3mm) spacing, using minimum nominal 1"(25mm) thick lumber, a maximum 6"
(152mm) width, having adequate nail-holding capacity and a
smooth surface. Do NOT fasten shingles directly to insulation or insulated deck
unless authorized in writing by GAF. Roof decks and existing surfacing material must be dry prior to application of shingles.
UNDERLAYMENT (LEAK BARRIER): Install GAF leak barrier at the eaves in localities where leaks may be caused by water ba cking up behind
ice or debris dams.
UNDERLAYMENT (ROOF DECK PROTECTION): Underlayment beneath shingles has many benefits, including helping to prevent wind-driven
rain from reaching the interior of the building and to prevent sap in some wood decking from reacting with asphalt shingles. When an
underlayment is installed, use a breather-type underlayment, such as GAF Shingle-Mate
®
or Deck-Armor
underlayments. GAF Tiger Paw
underlayment, with its moisture control design, can also be used. Always have a design professional review ventilation requirements when
using a moisture control design underlayment. Underlayment is also required by many code bodies and is required to maintain the shingles’
UL Class A fire rating. When using FeltBuster™High-Traction Synthetic Roofing Felt asunderlayment,itMUST be installed over one layer of
VersaShield
®
Fire-ResistantRoofDeckProtection in order to maintain a Class A fire rating for GAF asphalt shingles.
FASTENERS: Use only zinc-coated steel or aluminum, 10-12 gauge, barbed, deformed, or smooth shank roofing nails with heads 3/8" (10mm)
to 7/16" (12mm) in diameter. Fasteners should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through the plywood
decks. Fasteners must be driven flush with the surface of the shingle. Overdriving will damage the shingle. Raised fasteners will interfere with
the sealing of the shingles and can back out.
• ASPHALT PLASTIC CEMENT: Use asphalt plastic cement conforming to ASTM D4586 Type I or II.
WIND RESISTANCE/HAND SEALING: These shingles have a special thermal sealant that firmly bonds the shingles together a fter applica
tion
when exposed to sun and warm temperatures. Shingles installed in fall or winter may not seal until the following spring. If shingles are damaged
by winds before sealing or are not exposed to adequate surface temperatures, or if the self-sealant gets dirty, the shingles may never seal.
Failure to seal under these circumstances results from the nature of self-sealing shingles, and is not a manufacturing defect. If shingles are
to be applied during PROLONGED COLD periods or in areas where airborne dust or sand can be expected before sealing occurs, the shingles
MUST be hand sealed. See Nailing Instructions / Hand Sealing.
MANSARD AND STEEP SLOPE APPLICATIONS: For roof slopes grea ter than 21" per foot (1750mm/m), shingle must be hand sea
led. DO NOT
use on vertical side walls.
RELEASE FILM: Plastic film strips are present either on the back or face of each shingle. The film strips are to prevent shingles from sticking
together while in the bundle. Do not remove the film strip before or during the application.
THROUGH VENTILATION: For optimal shingle life and to help prevent mold growth, all roof structures must have through ventilation to prevent
entrapment of moisture-laden air behind roof sheathing. Ventilation must be designed to meet or exceed current F.H.A., H.U.D., or local code
minimum requirements. Note: Minimum net free ventilation area of 1 sq. foot per 150 sq. feet (1 sq. meter per 150 sq. meters) of ceiling area
is required. When vents are located at the eaves and near the roof’s peak (balanced) for maximum air flow, ventilation may be reduced to 1 sq.
foot per 300 sq. feet (1 sq. meter per 300 sq. meters).
• EXPOSED METAL: Paint all exposed metal surfaces (flashing, vents, etc.) with m
atching GAF Shingle-Match
roof accessory paint for
best appearance.
• NOTE: All drawings not drawn to scale.
INSTRUCCIONES GENERALES
• HOJAS DE DATOS DE SEGURIDAD (SDS): Cuando utilice los productos de GAF, tales como tejas, bases de pisos, cemento plástico, etc.,
consulte las SDS correspondientes. Las versiones más actuales están disponibles en es.gaf.com. GAF no proporciona hojas de datos de
seguridad ni instrucciones de instalación para productos que no sean fabricados por GAF. Consulte al fabricante del material para sus SDS e
instrucciones de instalación según corresponda.
• PLATAFORMAS BASE DE TECHOS: Use una plataforma base de 3/8" (10mm) de madera terciada u madera aglomerada orientada (OSB por
sus siglas en inglés) como mínimo según lo recomendado por la Asociación Americana de Madera Terciada (APA por sus siglas en inglés).
Las cubiertas de madera deben estar bien preparadas y apoyadas, con un espacio máximo de 1/8" (3mm), con un espesor mínimo nominal de
1"(25mm), con un ancho máximo de 6" (152mm), y una capacidad de retención de clavos adecuada y una superficie suave. NO asegure las
tejas directamente al aislante o a la plata
forma base aislada a menos que sea autorizado por escrito por GAF. Las plataformas base de techo y
material de superficie existentes deben estar secas antes de la aplicación de las tejas.
CAPA BASE (barrera contra goteras): Instale barrera de filtraciones de GAF en los aleros en lugares donde el estancamiento de agua detrás de
hielo o desechos podría causar filtraciones.
CAPA BASE (PROTECCIÓN PARA CUBIERTAS DE TECHOS): La capa base deb
ajo de las tejas tiene muchos beneficios, incluyendo el ayudar a
evitar que la lluvia arrastrada por el viento alcance el interior del edificio y evitar que la savia de algunas plataformas de madera reaccione con
l as tejas asfálticas. Donde vaya a instalar una capa base, use una de tipo respira ble como las capas base ShingleMate
®
o Deck-Armor
de GAF.
También se puede utilizar la capa base Tiger Paw
de GAF, con su diseño de control de la humedad. Siempre pida a un profesional en diseño
que revise los requisitos de ventilación cuando utilice una capa base con diseño de control de la humedad. La capa base también es requerida
por muchos códigos de construcción para mantener la calificación Clase A de UL contra incendios. Cuando utilice el Fieltro Sintético De
Alta Tracción FeltBuster™ Para Techos como capa base, DEBE instalarse sobre una capa de Protección de la Cubierta del Techo Ignífuga
VersaShield
®
con el fin de mantener una clasificación Clase A contra incendios para las tejas asfálticas GAF.
2.
INSTRUCTIONS GÉNÉRALES
FICHE DONNÉES DE DONNÉES DE PRODUIT: Quand vous utilisez des produits GAF, comme des bardeaux, des membranes de protection,
du ciment plastique, etc., veuillez vous référer à la fiche signalétique de données de produit. Les versions les plus à jour sont disponibles sur
le site fr.gaf.ca. GAF ne fournit pas de fiche signalétique de données de produit ni d’instructions d’installation pour des produits qui ne
sont pas fabriqués par GAF. Veuillez consulter le fabricant du matériau pour leur fiche signalétique de données de produit et les instructions
d’installation au besoin.
• PLATELAGES DE TOIT: Utiliser du platelage en contreplaqué ou en OSB d’un minimum de 10mm (3/8po) tel que recommandé par APA - The
Engineered Wood Assn. Les platelages en bois doivent être bien asséchés et supportés et avoir un espacement minimum de 1/8po (3mm), être
construits avec du bois d’oeuvre d’une largeur nominale minimale de 1po (25mm) d’épaisseur, une largeur maximale de 6po (152mm) ayant
une capacité de support des clous adéquate ainsi qu’une surface lisse. NE pas fixer les bardeaux directement sur l’isolant ou sur des platelages
isolés sauf si autorisé par écrit par GAF. Les platelages de toit et les matériaux de surface existants doivent être secs avant l’application
de bardeaux.
• MEMBRANE DE PROTECTION (PARE-FUITE): Installer du pare-fuite de GAF aux avant-toits dans les localités où des fuites pourraient être
causées par de l’eau qui s’accumulerait derrière des amoncellements de débris ou de glace.
MEMBRANE DE PROTECTION (PROTECTION DE PLATELAGE DE TOIT): La
membrane de protection sous les bardeaux comporte plusieurs
avantages, notamment le fait de contribuer à empêcher la pluie portée par le vent de pénétrer à l’intérieur du bâtiment et d’empêcher la
sève contenue dans certains platelages en bois de réagir avec les bardeaux d’asphalte. Là où une feuille de protection sera utilisée, utiliser
une feuille de protection qui respire comme Shingle-Mate
MD
ou Deck-Armor
MC
de GAF. La membrane de protection Tiger Paw
MC
GAF avec son
design de contrôle d’humidité peut aussi être utilisée. Assurez-vous toujours qu’un professionnel du design révise les exigences en ventilation
lors de l’utilisation d’une membrane de protection au design à contrôle d’humidité. Une feuille de protection est aussi exigée par plusieurs
corps réglementaires et est requise pour maintenir un classement de résistance au feu de Classe A. Lors de l’utilisation de Feutre À Toiture
Synthétique Adhérent FeltBuster
MC
comme membrane de protection, DOIT être installé sur une couche de Protection de Platelage de Toit
Résistant au Feu VersaShield
MD
afin de maintenir une cote de résistance au feu de Classe A pour les bardeaux d’asphalte GAF.
ATTACHES/FIXATIONS: Utiliser uniquement des clous en acier galvanisé ou en aluminium, de calibre 10-12, à tige indentée, déformés ou des
clous à toiture à tige lisse avec des têtes de 10mm à 12mm (3/8po - 7/16po) de diamètre. Les clous doivent être assez longs pour pénétrer
d’au moins 19mm (3/4po) dans le platelage du toit ou juste au travers du platelage du toit. Les clous doivent être entraînés à effleurement avec
la surface du bardeau. Trop les enfoncer endommagera le bardeau. Les clous relevés vont interférer avec la résistance aux vents des bardeaux.
CIMENT PLASTIQUE ASPHALTÉ: Utiliser du ciment plastique asphalté qui est conforme à ASTM D4586 Type I ou II.
• RÉSISTAN
CE AUX VENTS / SCELLEMENT À LA MAIN: Ces bardeaux offrent un scellant thermique spécial qui colle fermement les bardeaux
ensemble après application lorsque exposés au soleil et aux températures chaudes. Les bardeaux installés en automne ou en hiver peuvent
ne pas sceller avant le printemps suivant. Si les bardeaux sont endommagés par les vents avant le scellement ou qu’ils ne sont pas exposés à
des températures de surface adéquates, ou si l’auto-scellant est sale, les bardeaux peuvent ne jamais se sceller. Le manquement à sceller dans
de telles circonstances résulte de la nature même des bardeaux
autoadhésifs et non pas d’un vice de fabrication. Si des bardeaux doivent être
appliqués durant des périodes de FROID PROLONGÉ ou dans des endroits où la poussière dans l’air peut être anticipée avant le scellement, les
bardeaux DOIVENT être scellés à la main. Voir les instructions de Clouage / Scellement à la main.
• APPLICATIONS AUX MANSARDES ET AUX PENTES FORTES: Pour des pentes de toiture de plus de 1750mm/m (21po par pied, le bardeau doit
être scellé à la main. Ne PAS utiliser sur des murs verticaux.
• PELLICULE DE DÉGAGEMENT: Les bandes de pellicule de plastique sont présentes tant au verso ou à l’endos de chaque bardeau. Les bandes
de film sont destinées à empêcher les bardeaux de s’agglutiner les uns aux autres lorsqu’ils sont groupés par lot. Ne pas retirer
l
a bande de pellicule avant ou durant l’application.
• AÉRATION DE BÂTIMENT: Pour une durée de vie optimale du bardeau et pour aider à prévenir la croissance de moisissure, toutes les structures
du toit doivent avoir suffisamment de ventilation pour prévenir l’emprisonnement d’air vicié humide derrière le platelage de toit. La ventilation
doit être conçue pour répondre ou dépasser les exigences actuelles des normes minimales F.H.A/H.U.D ou celles associées au code local
de construction. Remarque: Une surface de ventilation libre minimale de 1m
2
par 150m
2
(1pi
2
par 150pi
2
) de surface de plafond est requise.
Lorsque les évents sont situés aux avant-toits et près du faîte (dans une configuration bien équilibrée) pour un débit d’air ma ximum, la
ventilation peut être réduite à 1m
2
par 300m
2
(1pi
2
par 300pi
2
).
• MÉTAL EXPOSÉ: Peindre toutes les surfaces en métal exposées (solin, évents, etc.) avec de la peinture pour accessoires ShingleMatch
MC
GAF
appariée pour une meilleure apparence.
• REMARQUE: Noter que toutes ces illustrations ne sont pas dessinées à l’échelle.
• SUJETADORES: Use únicamente clavos de techado de acero o aluminio galvanizados, de calibre 10-12, arponados, deformados o con espiga
suave con cabezas de 3/8" (10mm) a 7/16" (12mm) de diámetro. Los sujetadores deben ser suficientemente largos como para penetrar al
menos 3/4" (19mm) en las plataformas base de techos o apenas a través de las plataformas base de ma
dera terciada. Los sujetadores deben
ser clavados a nivel con la superficie de la teja. Clavar en exceso puede dañar la teja. Los clavos sobresalientes interferirán con el sellado de las
tejas, y pueden doblarse hacia atrás.
CEMENTO PLÁSTICO ASFÁLTICO: Use cemento plástico asfáltico conforme a los Tipos I o II de ASTM D4586.
• RESISTENCIA AL VIENTO / SELLADO A MANO: Estas tejas tienen un sellador térmico especial que firmemente une las tejas entre sí después
de la aplicación, cuando quedan expuestas al sol y a temperaturas cálidas. Las tejas instala das en otoño o invierno pueden no sellar hasta la
primavera siguiente. Si las tejas son dañadas por los vientos antes de sellar o no son expuestas a temperaturas de superficie adecuadas, o si
el auto-sellante se ensucia, las tejas podrían no sella
r jamás. La imposibilida d de sellar bajo estas circunstancias resulta de la naturaleza de las
tejas auto-sellantes y no es un defecto de fábrica. Si las tejas deben ser aplicada s durante períodos PROLONGADOS DE FRÍO o en áreas donde
se puede esperar la presencia de polvo o arena en el a ire antes que el sellado ocurra, las tejas DEBEN ser selladas a mano. Ver instrucciones
de clavado/sellado a mano.
• APLICACIONES EN BUHARDILLAS Y PENDIENTES ESCARPADAS: Para pendientes de techos superiores a las 21" por pie (1750mm/m), la teja
debe ser sellada a mano. NO usar en paredes laterales verticales.
• PELÍCULA SEPARADORA: Las tiras separadoras de plástico están presentes o bien en la parte posterior o en la cara de cada teja.
Las telas separadoras sirven para evitar que las tejas se peguen entre si estando en el manojo. No retire la banda de película antes o durante
la aplicación.
• VENTILACIÓN PASANTE: Para la vida útil óptima de las tejas y para ayudar a prevenir el crecimiento de moho, todas las estructuras del
techo deben tener ventilación continua para evitar el atrapamiento de aire cargado de humeda d detrás del revestimiento del techo.
La ventilación debe estar diseñada para cumplir o exceder los requerimientos mínimos actualizados de la F.H.A., H.U.D. o los requerimientos
de códigos locales. Nota: Se requiere un área mínima de ventilación libre de red de 1 pie cua drado por cada 150 pies cuadra
dos (1 metro
cuadrado por cada 150 metros cuadrados) de cielorraso. Cuando las ventilaciones estén colocadas en los aleros y cerca del pico del techo
(balanceadas) para un máximo flujo de aire, la ventilación puede reducirse a 1 pie cuadrado por cada 300 pies cuadrados (1 metro cuadra do
por cada 28 metros cuadrados).
• METAL EXPUESTO: Pinte todas las superficies de metal expuesto (vierteaguas, ventilaciones, etc.) con la pintura de accesorio para techos GAF
ShingleMatch
para una mejor apariencia.
• NOTA: Las ilustraciones no están hechas a escala.
GAF Roof Deck Protection
Protección de Plataforma Base
de Techos de GAF
Protection de Platelage
de Toit GAF
Sheathing
Revestimento
Voligeage
Along rake, put non-corroding
metal drip edge on top of GAF
Roof Deck Protection.
Exposure will vary depending on GAF
Underlayment used. Follow application
instructions on selected underlayment
for proper exposure.
La exposición variará en función de
la Capa Base de GAF utilizada. Siga las
instrucciones de aplicación en la capa
base seleccionada para una
exposición adecuada.
Le pureau peut varier selon la Membrane
de Protection GAF utilisée. Suivre les
instructions d’application sur les membranes
de protection sélectionnées pour le
pureau adéquat.
A lo largo del alero, coloque borde
de goteo de metal inoxidable encima
de la Protección de la Cubierta
de Techo de GAF.
Along eaves, put GAF Leak Barrier
on top of non-corrosive
metal drip edge.
A lo largo de los aleros, coloque
la Barrera Contra Goteras de GAF sobre
el borde de goteo de metal inoxidable.
GAF Leak Barrier
Barrera Contra Goteras de GAF
Not more than 1/4" (6 mm) roof overhang
No más que 1/4" (6 mm) techo sobresale por encima de
GAF Roof Deck Protection
Protección de la Cubierta
de Techo de GAF
Au long de l’inclinaison, mettre un
larmier en métal inoxydable sur le
dessus de la Protection de Platelage
de Toit GAF.
Pas plus que 6 mm (1/4 po) le surplomb de toit
Au long des avant-toits, mettre
du Pare-Fuite de GAF sur le
dessus du larmier en métal
inoxydable.
Sheathing
Revestimento
Voligeage
Protection de Platelage
de Toit GAF
Pare-Fuite de GAF
4.
INSTALLING UNDERLAYMENT
INSTALANDO LA CAPA BASE
INSTALLATION DE LA MEMBRANE DE PROTECTION
UNDERLAYMENT: FOR ROOF SLOPES 2:12 TO LESS THAN 4:12
Application of eave flashing: At eaves and where ice dams can be expected, use one layer of GAF Leak Barrier. Eave flashing must not overhang
the eave edge by more than 1/4" (6mm) and should extend 24" (610mm) beyond the inside wall line. Where ice dams or debris dams are not
expected, install 2 plies of GAF Roof Deck Protection. Application of underlayment: Completely cover the deck with two layers of GAF Roof
Deck Protection as shown. Use only enough nails to hold underlayment in place until covered by shingles.
CAPA BASE: PARA TECHOS CON PENDIENTES DE 2:12 A MENOS DE 4:12
Aplicación de vierteaguas para aleros: En los aleros y donde se pueda esperar la presencia de estancamientos de hielo, use una Capa de
Barrera de Filtraciones de GAF. El vierteaguas para aleros no debe sobres
alir el borde del techo más de 1/4" (6mm) y extenderse 24" (610mm)
más allá de la línea interior de la pared. Donde no se esperen estancamientos de hielo o escombros, instale 2 pliegues de Protección de
Plataformas Base de Techos de GAF. Aplicación de capa base: Cubra completamente la plataforma base con dos capas de Protección de
Plataformas Base de Techos de GAF como se muestra. Use solamente la cantidad suficiente de clavos como para sostener la capa base en su
lugar hasta que la haya cubierto con las tejas.
MEMBRANE DE PROTE
CTION: POUR PENTE DE TOIT DE 2:12 À MOINS DE 4:12
Application de solin d’avant-toit: Au niveau des avant-toits et aux endroits où les accumulations de glace peuvent survenir, veuillez utiliser une
couche Pare-Fuite de GAF. Le solin d’avant-toit ne doit pas surplomber le rebord de l’avant-toit de plus de 1/4po (6mm) et doit s’étendre à plus
de 24po (610mm) au-delà de la ligne du mur intérieur. Lorsque vous n’anticipez pas d’accumulation de glace ou de débris, veuillez installer 2
couches de Protection de Platelage de Toit GAF. Application d’une membrane de protection: Recouvrir complètement la plateforme du toit avec
deux couches protection de platelage de toit GAF, tel que spécifié ci-contre. Utiliser suffisamment de clous pour maintenir en place la membrane
de protection jusqu’à ce qu’elle soit recouverte de bardeaux.
Start at either rake and lay in either direction
Along rake, put non-corroding
metal drip edge on top of GAF
Roof Deck Protection.
A lo largo del alero, coloque
borde de goteo de metal
inoxidable encima de la
protección de Plataforma Base
del Techo de GAF.
4" (102mm) minimum vertical lap
Solape vertical mínimo de 4" (102mm)
Along eaves, put GAF
Leak Barrier on top of
non-corrosive metal drip edge.
A lo largo de los aleros, coloque
la Barrera de Filtraciones de GAF
sobre el borde de goteo de
metal inoxidable.
2" (51mm) minimum horizontal lap
2" (51mm) minimum horizontal lap
Solape horizontal mínimo de 2" (51mm)
Solape horizontal mínimo de 2" (51mm)
Chevauchement horizontal minimum de 51mm (2po)
Not more than 1/4" (6mm) roof overhang
No más que 1/4" (6mm) techo sobresale por encima de
Au long de l’inclinaison, mettre un
larmier en métal inoxydable sur le
dessus de la protection de
Platelage de Toit GAF.
Chevauchement vertical minimum de 102mm (4po)
Au long des avant-toits, mettre
du Pare-Fuite GAF sur le
dessus du larmier en métal
inoxydable.
Chevauchement horizontal minimum de 51mm (2po)
GAF Roof Deck Protection
Protección de Plataforma Base
de Techos de GAF
Protection de Platelage
de Toit GAF
GAF Leak Barrier
Barrera de Filtraciones de GAF
Pare-Fuite de GAF
Sheathing
Revestimento
Voligeage
Sheathing
Revestimento
Voligeage
Pas plus que 6mm (1/4 po) le surplomb de toit
For maximum wind resistance along rakes, install
any GAF Starter Strip shingles which contain sealant
or cement shingles to underlayment and each other
in a 4" (102mm) width of asphalt plastic cement.
Para máxima resistencia al viento a lo largo de
las inclinaciones, instale cualquier teja de
Hilada Inicial de GAF con conteniendo sellador
o cemente las tejas a la capa base y entre sí en
un ancho de 4" (102mm) de cemento
plástico asfáltico.
Pour une résistance maximale contre les vents
le long des inclinaisons, installer des bardeaux
de Bande de Départ GAF avec scellant ou
coller les bardeaux à la membrane de
protection et l’un à l’autre dans une largeur
de ciment plastique asphalté de 4po (102mm).
Place starter strip shingles 1/4" – 3/4" (6 – 19mm) over
eave and rake edges to provide drip edge.
Coloque las tejas de hilada inicial a 1/4" – 3/4" (6 – 19mm)
sobre los bordes de alero e inclinación para proporcion r borde de goteo.
Overlap eave edge starter strip
at least 3" (76mm).
Traslape la hilada inicial del borde
de alero por lo menos 3" (76mm).
Non-corroding metal drip edge
Borde de goteo de metal inoxidable
Nail approximately 1-1/2"
– 3" (38 – 76mm)
above the butt edge of the shingle.
Clave aproximadamente a 1-1/2" – 3" (38 – 76mm)
por encima del borde de empalme de la teja.
GAF Underlayment
Barrera de Filtraciones de GAF
Pare-Fuite de GAF
Placer le bardeau à 6 – 19mm (1/4 à 3/4po) sur les rebords de
l’avant-toit et de l’inclinaison pour fournir un larmier.
Chevaucher la bande de départ
de le rebord de l’avant-toit par
au moins 76mm (3po).
Larmier en Métal Inoxydable
Clouer à 38 – 76mm (1-1/2 à 3po) en haut du
rebord du bardeau.
5"
(127m
m)
5.
UNDERLAYMENT: FOR ROOF SLOPES 4:12 OR MORE
Application of eave flashing: At eaves and where ice dams can be expected, use one layer of GAF Leak Barrier. Eave flashing must extend 24"
(610mm) beyond the inside wall line. Application of underlayment: Cover deck with one layer of GAF Roof Deck Protection installed without
wrinkles. Use only enough nails to hold underlayment in place until covered by shingles.
CAPA BASE: PARA TECHOS CON PENDIENTES DE 4:12 O MÁS
Aplicación de vierteaguas para aleros:
En los aleros y donde se pueda esperar la presencia de estancamientos de hielo, use una Capa de
Barrera de Filtraciones de GAF.
El vierteaguas para aleros extenderse 24" (610mm) más allá de la línea interior de la pared.
Aplicación de capa base: Cubra la plataforma base con una capa de capa base de GAF instalada sin arrugas. Use solamente la cantidad
suficiente de clavos como para sostener la capa base en su lugar hasta que la haya cubierto con las tejas.
MEMBRANE DE PROTECTION: FOR ROOF PENTES DE 4:12 OU PLUS
Application de solin d’avant-toit: Au niveau des avant-toits et aux endroits où les accumulations de glace peuvent survenir, veuillez utiliser
une couche Pare-Fuite de GAF. Le solin d’avant-toit doit s’étendre de 24po (610mm) au-delà de la ligne du mur intérieur.
Application d’une
membrane de protection: Couvrir le platelage avec une couche de Protection de Platelage de Toit GAF installée sans plissement. Utiliser
suffisamment de clous pour maintenir en place la membrane de protection jusqu’à ce qu’elle soit recouverte de bardeaux.
I
NSTALLING STARTER STRIP SHINGLES
INSTALACIÓN DE TEJAS DE HILADA INICIAL
INSTALLATION DES BARDEAUX DE BANDE DE DÉPART
STARTER COURSE
Use GAF starter strip shingles along the eaves and rake. Apply as shown.
NOTE:
GAF starter strip shingles are recommended at the rakes for best performance
and required for enhanced warranty coverage on certain products (see limited warranties for details). Refer to application instructions for the selected starter
strip shingles.
HILADA INICIAL
Use tejas de hilera inicial de GAF en los aleros. Aplicar como se muestra
las inclinaciones
.
NOTA:
Se recomienda usar tejas de hilera inicial de GAF en
las inclinaciones para mejor rendimiento y se requiere para cobertura de la garantía contra el viento en ciertos productos (consulte la garantía limitada para
detalles).
Siga las instrucciones de aplicación de tejas de hilada inicial.
RANG DE DÉPART
Utiliser les bardeaux de bande de départ de GAF le long des avant-toits
et inclinaison
. Appliquer tel qu’indiqué.
REMARQUE:
Les bardeaux de bande de
départ GAF sont recommandés aux inclinaisons pour une meilleure performance et sont requis pour une couverture de garantie accrue contre les vents sur
certains produits (voir la garantie limitée pour les détails).
Suivre les instructions d’application des bardeaux de bande de départ.
17"
(432mm)
11"
(2
79mm)
2nd
course
6"
(152mm)
1st course
11"
(279mm)
6"
(152
mm)
1st course
Third Course
Tercer Curso
Troisième Cours
Third Course
Tercer Curso
Troisième Cours
Fourth Course
Cuarto curso
Quatrième cours
Fourth Course
Cuarto curso
Quatrième cours
GAF Underlayment
Barrera de Filtraciones de GAF
Pare-Fuite de GAF
GAF Underlayment
Barrera de Filtraciones de GAF
Pare-Fuite de GAF
Trim 11" (279mm)
from rake end of first shingle.
Recorte 11" (279mm) del
borde de inclinación
de la primera teja.
Découper à 279mm
(11po) du bout du
premier bardeau.
Recorte 17" (432mm) del lado que va
al borde en la primera teja. Continúe con tejas
completas. Repita de la 1ra a la 4ta instrucciones
de hilada en las hiladas restantes, comenzando
la quinta hilada con una teja completa.
Découper à 432mm (17po) de la fin de
râteau de premier bardeau. Continuer avec des
bardeaux entiers. Répéter les instructions du 1er
au 4ème rang sur les rangs restants, en commençant
au cinquième rang avec un bardeau entier.
Trim 17" (432mm) from rake end
of first shingle. Continue with whole shingles.
Repeat the 1st - 4th course instructions on
the remaining courses, starting the fifth
course with a full shingle.
THIRD COURSE
TERCERA HILADA
TROISIÈME RANG
4TH COURSE AND REMAINING
Strike a chalk line about every 6 courses to check parallel alignment with eaves.
4TA. HILADA Y RESTANTES
Trace una línea de tiza aproximadamente cada 6 hiladas para controlar la alineación paralela con los a leros.
4ÈME RANG ET LES RANGS RESTANTS
Tracer une ligne de craie à environ tous les 6 rangs pour vérifier l’alignement en parallèle avec les avant-toits.
7.
Siding
Tinglado
Parement
Sheathing
Revestimento
Voligeage
Sheathing
Revestimento
Voligeage
Sheathing
Revestimento
Voligeage
Sheathing
Revestimento
Voligeage
Metal flashing (Nailed to the
deck, NOT to the vertical wall)
extend up wall at least
5" (127mm).
El vierteaguas de metal (Clavado a la
plataforma base, NO a la pared vertical)
se extiende hacia arriba por la pared
5" (127 mm).
Extend GAF Leak Barrier
at least 5" (127mm) up wall.
Extienda la barrera para
goteras de GAF por al menos
5" (127 mm) hasta la pared.
Cover metal flashing with
cut shingle. Do NOT nail
shingle, install with asphaltic
plastic cement.
Cubra el vierteaguas de metal
con tejas cortadas. NO clave
las tejas, instale con cemento
plástico asfáltico.
Siding/cladding must be at least 2" (51mm) above the
roof surface and covering flashing at least 2" (51mm).
El revestimiento/recubrimiento debe ser de al menos
2" (51mm) por encima de la superficie del techo y
cubrir el vierteaguas por lo menos 2" (51mm).
Step flashing pieces overlap
each other 2" (51mm)
Las piezas de vierteaguas escalonado
se traslapan entre si 2" (51mm)
Extend GAF Leak Barrier at least
5" (127mm) up wall.
Extienda la Barrera Para Goteras
de GAF por al menos
5" (127 mm) hasta la pared.
2 nails per step flashing
2 clavos por vierteaguas escalonado
Coloque tapajuntas metálico de paso
sólo expuso orilla de tablilla
y extiende 5" (127 mm) sobre tablilla
fundamental y 5" (127 mm) arriba
la pared vertical.
GAF Underlayment
Capa Base de GAF
Place metal step flashing just upslope
from exposed edge of shingle and extend
5" (127mm) over underlying shingle
and 5" (127mm) up the vertical wall.
Le recouvrement / bardage doit maintenir 2po (51mm)
au-dessus de la surface du toit et couvrir le solin au
minimum de 2po (51mm).
Les pièces de noquet se chevauchent
l’une l’autre de 51mm (2po)
Étendre du Pare-Fuite GAF à
5po (127mm) au minimum
sur le mur.
2 clous par noquet
Placer le clignotement métallique d'étape
juste a exposé le bord de bardeau et étend
5po (127mm) sur le bardeau fondamental et
5po (127mm) sur le mur vertical.
Membrane de Protection GAF
Solin en métal (Cloué au platelage et NON PAS
au mur vertical) s’étend à 5po (127mm)
au minimum du mur).
Recouvrir le solin en métal
avec un bardeau coupé.
NE PAS clouer le bardeau,
l’installer avec du ciment
plastique asphalté.
Étendre du Pare-Fuite GAF à
5po (127mm) au minimum
sur le mur.
VENTILATION
Install GAF ventilation products for optimal shingle life. See General Instructions and the “Through Ventilation section. Follow the application
instructions for the selected ventilation products.
VENTILACIÓN
Instale productos de ventilación de GAF para una óptima vida útil de la teja. Consulte las Instrucciones Generales y la sección “A Través de la
Ventilación. Siga las instrucciones de aplicación de los productos de ventilación seleccionados.
VENTILATION
Installer des produits de ventilation GAF pour une durée de vie optimale. Voir les Instructions Générales dans la section «Aération de Bâtiment».
Suivre les instructions d’application pour les produits de ventilation sélectionnés.
RIDGE CAP SHINGLES
Install GAF Ridge Cap Shingles following the application instructions shown on the GAF Ridge Cap Shingle wrapper. Position laps away from
prevailing wind direction.
TEJAS DE CUMBRERA
Instale las Tejas de Cumbrera de GAF siguiendo las instrucciones de aplicación que figuran en el envoltorio de las Teja de Cumbrera de GAF.
Coloque los solapes lejos de la dirección del viento predominante.
BARDEAUX DE FAÎTAGE
Installer des Bardeaux de Faîtage de GAF suivre les instructions d’installation montrées sur l’emballage des Bardeau de Faîtage de GAF.
Positionner les chevauchements loin de direction des vents dominants.
INSTALLING ROOF ACCESSORIES AND DETAILS
INSTALACIÓN DE ACCESORIOS Y DETALLES DE TECHO
INSTALLATION DES PRODUITS ROOF ACCESSORIES ET DÉTAILS
8.
WALL FLASHING (Sloped Roof to Wall)
VIERTEAGUAS DE PARED (Techo en Pendiente hacia la Pared)
SOLINS MURAUX (de Toit en Pente à Mur)
12.
PRECAUTIONARY NOTES
1. These shingles are fiberglass, self-sealing asphalt shingles. Because of the natural characteristics of the high-quality waterproofing material used, these shingles
will be stiff in cold weather and flexible in hot weather.
2. These shingles are particularly tough and may require additional effort to trim to fit on the roof. Curved blade utility knives are more effective than straight
blade utility knives in cutting these shingles. Using a circular saw equipped with carbide-tipped blades is also effective.
3. When using FeltBuster™High-Traction Synthetic Roofing Felt asunderlayment,itMUST be installed over one layer of VersaShield
®
Fire-Resistant Roof Deck
Protection in order to maintain a Class A fire rating for GAF asphalt shingles.
4. Regardless of the tool used, always wear proper protective gear such as gloves, eye protection, etc. In situations where dust or fumes are generated, e.g., cutting
shingles with a power saw, appropriate respiratory protection is recommended. Please refer to the SDS for further information and follow all safety procedures.
Use tools carefully to prevent personal injury when working with these products.
5. Handle carefully. Shingles can easily be broken in cold weather or their edges damaged in hot weather. Do not drop bundles on edge or on other bundles to
separate shingles. Do not load bundles across a hip or ridge. Do not bend bundles over shoulder for carrying. Premium shingles with heavier weight may cause
cra
cks at sharp bend points.
6. Store on flat surface in a covered, ventilated area-maximum temperature 110°F (43°C). Do not store near steam pipes, radiators, etc., or in sunlight.
7. Do not store double stacked pallets on a long – term basis. If double stacking is required for short periods, use slip sheets of 1/2" (13mm) plywood cut to the pallet
size to minimize damage. Long-term double stacked storage, especially in hot weather, can result in possible sticking, staining, and distortion of the shingles.
IMPORTANT: Repair leaks promptly to avoid adverse effects, including mold growth.
RE-ROOFING
If old asphalt shingles are to remain in place, nail down or cut away all loose, curled or lifted shingles and replace with new, and just before applying the new
roofing, sweep the surface clean of all loose debris. Since any irregula
rities may show through the new shingles, be sure the underlying shingles provide a smooth
surface. Fasteners must be long enough to penetrate the wood deck at least 3/4" (19mm) or just through plywood. Follow above instructions for application.
NOTE: Shingles can be applied over wood shingles if the surface can be made smooth enough. This may include cutting back old shingles at eaves and rakes,
installing new wood edging strips as needed, and the use of beveled wood strips. Install #30 underlayment to maintain Class A rating.
For technical support, call 1-800-766-3411 or visit our website at gaf.com.
NOTAS DE PRECAUCIÓN
1. Estas tejas son tejas asfálticas autosellantes de fibra de vidrio. Debido a las características naturales del material impermeable de alta calidad utilizado, estas tejas
serán duras en climas fríos y flexibles en climas cálidos.
2. Estas tejas son particularmente duras y pueden requerir un esfuerzo adicional en el recorte para encajarlas al techo. Los cuchillos utilitarios de hoja curva son más
efectivos que los cuchillos utilitarios de hoja recta para
cortar estas tejas. También es efectivo usar una sierra circular equipada con hojas con puntas de carburo.
3. Cuando utilice el Fieltro Sintético De Alta Tracción FeltBuster™ Para Techos como capa base, DEBE instalarse sobre una capa de Protección de la Cubierta del Techo
Ignífuga VersaShield
®
con el fin de mantener una clasificación Clase A contra incendios para las tejas asfálticas GAF.
4. Independientemente de la herramienta utilizada, siempre use la vestimenta apropiada, por ejemplo, guantes, protección para los ojos, etc. En situaciones donde
se genere polvo o humo, por ejemplo, al cortar las tejas con una sierra eléctrica, se recomienda utilizar la protección respiratoria apropiada. Consulte las SDS para
obtener más información y siga todos los procedimientos de seguridad.Utilice las herra
mientas cuidadosamente para prevenir las lesiones personales cuando
trabaje con estos productos.
5. Manipule con cuidado. Las tejas pueden romperse fácilmente en climas fríos o sus bordes pueden dañarse en climas cálidos. No arroje los manojos sobre el borde
o encima de otros manojos para separar las tejas. No cargue los manojos sobre un caballete o borde. No doble los manojos sobre los hombros para transportarlos.
El peso superior puede causar grietas en los puntos de pliegue afilados.
6. Almacene en un área cubierta y ventilada
– temperatura máxima 110°F (43°C). No almacene cerca de tuberías de vapor, radiadores, etc., o a la luz del sol.
7. No almacene pálets de apilado doble en períodos largos de tiempo. Si se requiere apilado doble durante períodos breves, es preciso utilizar láminas deslizantes de
1/2" (13mm) de madera terciada cortadas al tamaño del pálet para minimizar los daños. El almacenamiento de apilado doble a largo plazo, especialmente en climas
cálidos, puede resultar en posible pegado, ma
nchado y distorsión de las tejas.
IMPORTANTE: Repare las filtraciones rápidamente para evitar efectos adversos, incluyendo el crecimiento de moho.
RE-TECHADO
Si es preciso que las viejas tejas asfálticas permanezcan en su lugar, clave o corte cualquier teja suelta, curvada o levantada y reemplácela con una nueva, y justo
antes de aplicar el nuevo techo, barra la superficie hasta dejarla libre de cualesquiera residuos sueltos. Dado que cualquier irregularidad podría notarse a través de
las nuevas tejas, a
segúrese que las tejas subyacentes tengan una superficie lisa. Los sujetadores deben tener el largo suficiente como para penetrar la plataforma
base de madera por lo menos 3/4" (19mm) o a través de la madera terciada. Siga el resto de las instrucciones detalladas arriba para la aplicación.
NOTA: Las tejas pueden ser aplicadas sobre tejas de madera si la superficie puede ser suficientemente alisad
a. Esto puede incluir cortar las tejas viejas en los
aleros e inclinaciones e instalar nuevos bordes de madera según sea necesario y el uso de hiladas de madera biseladas. Instale capa base #30 para mantener la
calificación de Clase A.
Para soporte técnico, llame al 1-800-766-3411 o visite nuestro sitio Web en es.gaf.com.
REMARQUES DE PRÉCAUTION
1. Ces bardeaux sont en fibre de verre et sont des bardeaux auto-scellants. En raison des caractéristiques naturelles du matériau imperméabilisant de haute qualité
utilisé, ces bardeaux seront rigides en température froide et flexibles en température élevée.
2. Ces bardeaux sont particulièrement résistants et ils pourraient nécessiter des efforts additionnels pour les découper pour ajuster au toit. Des couteaux utilitaires
à lame incurvée sont plus efficaces que des couteaux utilitaires à lame droite pour la découpe de ces bardeaux. Il peut aussi être très efficace d’utiliser une scie
circulaire munie d’une lame à pointe au carbure.
3. Lors de l’utilisation de Feutre À Toiture Synthétique Adhérent FeltBuster
MC
comme membrane de protection, DOIT être installé sur une couche de Protection de
Platelage de Toit Résistant au Feu VersaShield
MD
afin de maintenir une cote de résistance au feu de Classe A pour les bardeaux d’asphalte GAF.
4. Sans égard à l’outil utilisé, toujours porter des vêtements de protection appropriés, c’est à dire des gants, des protections oculaires, etc. Dans des situations où des
émanations ou de la poussière sont produites, comme de couper des bardeaux avec une scie électrique, une protection respiratoire appropriée est recommandée.
Veuillez vous référer à la fiche signalétique de données de produit pour plus d’information et conformez-vous à toutes les procédures de données. Utiliser vos outils
de manière sécuritaire pour prévenir toute blessure personnelle lors de travaux avec ces produits.
5. Manipule con cuidado. Las tejas pueden romperse fácilmente en climas fríos o sus bordes pueden dañarse en climas cálidos. No arroje los manojos sobre el borde
o encima de otros manojos para separar las tejas. No cargue los manojos sobre un caballete o borde. No doble los manojos sobre los hombros para transportarlos.
Las tejas de calidad superior con mayor peso pueden causar grietas en los puntos de pliegue afilados.
6. Entreposer sur une surface plane, dans un endroit couvert et ventilé – à une température maximale de 43°C (110°F). Ne pas entreposer près de conduites de
vapeur, du chauffage, etc.,ou au soleil.
7. Ne pas ranger des palettes empilées en double pour une longue période. Si un empilage en double est requis pour de courtes périodes, il est nécessaire de glisser
un contreplaqué de 13mm (1/2po) découpé à la taille des palettes entre les palettes pour minimiser les dommages. Le rangement à long terme en empilage en
double, spécialement en température chaude, peut résulter possiblement en collement, distorsion ou en tache sur les bardeaux.
IMPORTANT: Réparez les fuites prestement afin d’éviter les effets néfastes tels que la formation de moisissure.
RÉFECTION DE TOITURE
Si des vieux bardeaux d’asphalte doivent demeurer en place, clouer ou couper tout bardeau lâche, incurvé ou soulevé et remplacer avec du neuf, et juste avant
d’appliquer le nouveau recouvrement, balayer la surface pour qu’elle soit libre de tout débris. Puisque toute irrégularité va paraître au travers des nouveaux
bardeaux,
assurez-vous que les bardeaux sous-jacents offrent une surface lisse. Les fixations doivent être suffisamment longues pour pénétrer le platelage de toit
d’au moins 19mm (3/4po) ou juste au travers du contreplaqué. Suivre les instructions ci-dessous pour l’application.
REMARQUE: Les bardeaux peuvent être installés sur des bardeaux de bois si la surface peut être suffisamment aplanie. Ceci peut nécessiter la taille des vieux
bardeaux aux avant-toits et aux inclinaisons ainsi que l’installation de nouvelles plates-bandes en bois, au besoin, et l’utilisation de bandes en bois biseautées.
Installez une membrane de protection #30 pour maintenir une cote de Classe A.
Pour du soutien technique, appeler au 1-800-766-3411 ou visiter notre site Web au fr gaf.ca
©2014 GAF 7/14

Transcripción de documentos

Quality You Can Trust…From North America’s Largest Roofing Manufacturer!™ ¡Calidad En La Que Usted Puede Confi ar...Del Fabricante De Techos Más Grande De Norteamérica!™ Une Qualité À Laquelle Vous Pouvez Vous Fier... Du Plus Gros Fabricant De Toitures En Amérique Du Nord! MC INSTALLATION INSTRUCTIONS · INSTRUCCIONES DE INSTALACIÓN · INSTRUCTIONS D’INSTALLATION GENERAL INSTRUCTIONS • SAFETY DATA SHEETS: When using GAF products, e.g., shingles, underlayments, plastic cement, etc., please refer to the applicable SDS. The most current versions are available at gaf.com. GAF does not provide safety data sheets or installation instructions for products not manufactured by GAF. Please consult the material manufacturer for their SDS and installation instructions where appropriate. • ROOF DECKS: Use minimum 3/8" (10mm) plywood or OSB decking as recommended by APA-The Engineered Wood Assn. Wood decks must be well-seasoned and supported having a maximum 1/8" (3mm) spacing, using minimum nominal 1"(25mm) thick lumber, a maximum 6" (152mm) width, having adequate nail-holding capacity and a smooth surface. Do NOT fasten shingles directly to insulation or insulated deck unless authorized in writing by GAF. Roof decks and existing surfacing material must be dry prior to application of shingles. • UNDERLAYMENT (LEAK BARRIER): Install GAF leak barrier at the eaves in localities where leaks may be caused by water backing up behind ice or debris dams. • UNDERLAYMENT (ROOF DECK PROTECTION): Underlayment beneath shingles has many benefits, including helping to prevent wind-driven rain from reaching the interior of the building and to prevent sap in some wood decking from reacting with asphalt shingles. When an underlayment is installed, use a breather-type underlayment, such as GAF Shingle-Mate® or Deck-Armor™ underlayments. GAF Tiger Paw™ underlayment, with its moisture control design, can also be used. Always have a design professional review ventilation requirements when using a moisture control design underlayment. Underlayment is also required by many code bodies and is required to maintain the shingles’ UL Class A fire rating. When using FeltBuster™ High-Traction Synthetic Roofing Felt as underlayment, it MUST be installed over one layer of VersaShield® Fire-Resistant Roof Deck Protection in order to maintain a Class A fire rating for GAF asphalt shingles. • FASTENERS: Use only zinc-coated steel or aluminum, 10-12 gauge, barbed, deformed, or smooth shank roofing nails with heads 3/8" (10mm) to 7/16" (12mm) in diameter. Fasteners should be long enough to penetrate at least 3/4" (19mm) into wood decks or just through the plywood decks. Fasteners must be driven flush with the surface of the shingle. Overdriving will damage the shingle. Raised fasteners will interfere with the sealing of the shingles and can back out. • ASPHALT PLASTIC CEMENT: Use asphalt plastic cement conforming to ASTM D4586 Type I or II. • WIND RESISTANCE/HAND SEALING: These shingles have a special thermal sealant that firmly bonds the shingles together after application when exposed to sun and warm temperatures. Shingles installed in fall or winter may not seal until the following spring. If shingles are damaged by winds before sealing or are not exposed to adequate surface temperatures, or if the self-sealant gets dirty, the shingles may never seal. Failure to seal under these circumstances results from the nature of self-sealing shingles, and is not a manufacturing defect. If shingles are to be applied during PROLONGED COLD periods or in areas where airborne dust or sand can be expected before sealing occurs, the shingles MUST be hand sealed. See Nailing Instructions / Hand Sealing. • MANSARD AND STEEP SLOPE APPLICATIONS: For roof slopes greater than 21" per foot (1750mm/m), shingle must be hand sealed. DO NOT use on vertical side walls. • RELEASE FILM: Plastic film strips are present either on the back or face of each shingle. The film strips are to prevent shingles from sticking together while in the bundle. Do not remove the film strip before or during the application. • THROUGH VENTILATION: For optimal shingle life and to help prevent mold growth, all roof structures must have through ventilation to prevent entrapment of moisture-laden air behind roof sheathing. Ventilation must be designed to meet or exceed current F.H.A., H.U.D., or local code minimum requirements. Note: Minimum net free ventilation area of 1 sq. foot per 150 sq. feet (1 sq. meter per 150 sq. meters) of ceiling area is required. When vents are located at the eaves and near the roof’s peak (balanced) for maximum air flow, ventilation may be reduced to 1 sq. foot per 300 sq. feet (1 sq. meter per 300 sq. meters). • EXPOSED METAL: Paint all exposed metal surfaces (flashing, vents, etc.) with matching GAF Shingle-Match™ roof accessory paint for best appearance. • NOTE: All drawings not drawn to scale. INSTRUCCIONES GENERALES • HOJAS DE DATOS DE SEGURIDAD (SDS): Cuando utilice los productos de GAF, tales como tejas, bases de pisos, cemento plástico, etc., consulte las SDS correspondientes. Las versiones más actuales están disponibles en es.gaf.com. GAF no proporciona hojas de datos de seguridad ni instrucciones de instalación para productos que no sean fabricados por GAF. Consulte al fabricante del material para sus SDS e instrucciones de instalación según corresponda. • PLATAFORMAS BASE DE TECHOS: Use una plataforma base de 3/8" (10mm) de madera terciada u madera aglomerada orientada (OSB por sus siglas en inglés) como mínimo según lo recomendado por la Asociación Americana de Madera Terciada (APA por sus siglas en inglés). Las cubiertas de madera deben estar bien preparadas y apoyadas, con un espacio máximo de 1/8" (3mm), con un espesor mínimo nominal de 1"(25mm), con un ancho máximo de 6" (152mm), y una capacidad de retención de clavos adecuada y una superficie suave. NO asegure las tejas directamente al aislante o a la plataforma base aislada a menos que sea autorizado por escrito por GAF. Las plataformas base de techo y material de superficie existentes deben estar secas antes de la aplicación de las tejas. • CAPA BASE (barrera contra goteras): Instale barrera de filtraciones de GAF en los aleros en lugares donde el estancamiento de agua detrás de hielo o desechos podría causar filtraciones. • CAPA BASE (PROTECCIÓN PARA CUBIERTAS DE TECHOS): La capa base debajo de las tejas tiene muchos beneficios, incluyendo el ayudar a evitar que la lluvia arrastrada por el viento alcance el interior del edificio y evitar que la savia de algunas plataformas de madera reaccione con las tejas asfálticas. Donde vaya a instalar una capa base, use una de tipo respirable como las capas base ShingleMate® o Deck-Armor™ de GAF. También se puede utilizar la capa base Tiger Paw™ de GAF, con su diseño de control de la humedad. Siempre pida a un profesional en diseño que revise los requisitos de ventilación cuando utilice una capa base con diseño de control de la humedad. La capa base también es requerida por muchos códigos de construcción para mantener la calificación Clase A de UL contra incendios. Cuando utilice el Fieltro Sintético De Alta Tracción FeltBuster™ Para Techos como capa base, DEBE instalarse sobre una capa de Protección de la Cubierta del Techo Ignífuga VersaShield® con el fin de mantener una clasificación Clase A contra incendios para las tejas asfálticas GAF. 1. • SUJETADORES: Use únicamente clavos de techado de acero o aluminio galvanizados, de calibre 10-12, arponados, deformados o con espiga suave con cabezas de 3/8" (10mm) a 7/16" (12mm) de diámetro. Los sujetadores deben ser suficientemente largos como para penetrar al menos 3/4" (19mm) en las plataformas base de techos o apenas a través de las plataformas base de madera terciada. Los sujetadores deben ser clavados a nivel con la superficie de la teja. Clavar en exceso puede dañar la teja. Los clavos sobresalientes interferirán con el sellado de las tejas, y pueden doblarse hacia atrás. • CEMENTO PLÁSTICO ASFÁLTICO: Use cemento plástico asfáltico conforme a los Tipos I o II de ASTM D4586. • RESISTENCIA AL VIENTO / SELLADO A MANO: Estas tejas tienen un sellador térmico especial que firmemente une las tejas entre sí después de la aplicación, cuando quedan expuestas al sol y a temperaturas cálidas. Las tejas instaladas en otoño o invierno pueden no sellar hasta la primavera siguiente. Si las tejas son dañadas por los vientos antes de sellar o no son expuestas a temperaturas de superficie adecuadas, o si el auto-sellante se ensucia, las tejas podrían no sellar jamás. La imposibilidad de sellar bajo estas circunstancias resulta de la naturaleza de las tejas auto-sellantes y no es un defecto de fábrica. Si las tejas deben ser aplicadas durante períodos PROLONGADOS DE FRÍO o en áreas donde se puede esperar la presencia de polvo o arena en el aire antes que el sellado ocurra, las tejas DEBEN ser selladas a mano. Ver instrucciones de clavado/sellado a mano. • APLICACIONES EN BUHARDILLAS Y PENDIENTES ESCARPADAS: Para pendientes de techos superiores a las 21" por pie (1750mm/m), la teja debe ser sellada a mano. NO usar en paredes laterales verticales. • PELÍCULA SEPARADORA: Las tiras separadoras de plástico están presentes o bien en la parte posterior o en la cara de cada teja. Las telas separadoras sirven para evitar que las tejas se peguen entre si estando en el manojo. No retire la banda de película antes o durante la aplicación. • VENTILACIÓN PASANTE: Para la vida útil óptima de las tejas y para ayudar a prevenir el crecimiento de moho, todas las estructuras del techo deben tener ventilación continua para evitar el atrapamiento de aire cargado de humedad detrás del revestimiento del techo. La ventilación debe estar diseñada para cumplir o exceder los requerimientos mínimos actualizados de la F.H.A., H.U.D. o los requerimientos de códigos locales. Nota: Se requiere un área mínima de ventilación libre de red de 1 pie cuadrado por cada 150 pies cuadrados (1 metro cuadrado por cada 150 metros cuadrados) de cielorraso. Cuando las ventilaciones estén colocadas en los aleros y cerca del pico del techo (balanceadas) para un máximo flujo de aire, la ventilación puede reducirse a 1 pie cuadrado por cada 300 pies cuadrados (1 metro cuadrado por cada 28 metros cuadrados). • METAL EXPUESTO: Pinte todas las superficies de metal expuesto (vierteaguas, ventilaciones, etc.) con la pintura de accesorio para techos GAF ShingleMatch™ para una mejor apariencia. • NOTA: Las ilustraciones no están hechas a escala. INSTRUCTIONS GÉNÉRALES • FICHE DONNÉES DE DONNÉES DE PRODUIT: Quand vous utilisez des produits GAF, comme des bardeaux, des membranes de protection, du ciment plastique, etc., veuillez vous référer à la fiche signalétique de données de produit. Les versions les plus à jour sont disponibles sur le site fr.gaf.ca. GAF ne fournit pas de fiche signalétique de données de produit ni d’instructions d’installation pour des produits qui ne sont pas fabriqués par GAF. Veuillez consulter le fabricant du matériau pour leur fiche signalétique de données de produit et les instructions d’installation au besoin. • PLATELAGES DE TOIT: Utiliser du platelage en contreplaqué ou en OSB d’un minimum de 10mm (3/8po) tel que recommandé par APA - The Engineered Wood Assn. Les platelages en bois doivent être bien asséchés et supportés et avoir un espacement minimum de 1/8po (3mm), être construits avec du bois d’oeuvre d’une largeur nominale minimale de 1po (25mm) d’épaisseur, une largeur maximale de 6po (152mm) ayant une capacité de support des clous adéquate ainsi qu’une surface lisse. NE pas fixer les bardeaux directement sur l’isolant ou sur des platelages isolés sauf si autorisé par écrit par GAF. Les platelages de toit et les matériaux de surface existants doivent être secs avant l’application de bardeaux. • MEMBRANE DE PROTECTION (PARE-FUITE): Installer du pare-fuite de GAF aux avant-toits dans les localités où des fuites pourraient être causées par de l’eau qui s’accumulerait derrière des amoncellements de débris ou de glace. • MEMBRANE DE PROTECTION (PROTECTION DE PLATELAGE DE TOIT): La membrane de protection sous les bardeaux comporte plusieurs avantages, notamment le fait de contribuer à empêcher la pluie portée par le vent de pénétrer à l’intérieur du bâtiment et d’empêcher la sève contenue dans certains platelages en bois de réagir avec les bardeaux d’asphalte. Là où une feuille de protection sera utilisée, utiliser une feuille de protection qui respire comme Shingle-MateMD ou Deck-ArmorMC de GAF. La membrane de protection Tiger PawMC GAF avec son design de contrôle d’humidité peut aussi être utilisée. Assurez-vous toujours qu’un professionnel du design révise les exigences en ventilation lors de l’utilisation d’une membrane de protection au design à contrôle d’humidité. Une feuille de protection est aussi exigée par plusieurs corps réglementaires et est requise pour maintenir un classement de résistance au feu de Classe A. Lors de l’utilisation de Feutre À Toiture Synthétique Adhérent FeltBusterMC comme membrane de protection, DOIT être installé sur une couche de Protection de Platelage de Toit Résistant au Feu VersaShieldMD afin de maintenir une cote de résistance au feu de Classe A pour les bardeaux d’asphalte GAF. • ATTACHES/FIXATIONS: Utiliser uniquement des clous en acier galvanisé ou en aluminium, de calibre 10-12, à tige indentée, déformés ou des clous à toiture à tige lisse avec des têtes de 10mm à 12mm (3/8po - 7/16po) de diamètre. Les clous doivent être assez longs pour pénétrer d’au moins 19mm (3/4po) dans le platelage du toit ou juste au travers du platelage du toit. Les clous doivent être entraînés à effleurement avec la surface du bardeau. Trop les enfoncer endommagera le bardeau. Les clous relevés vont interférer avec la résistance aux vents des bardeaux. • CIMENT PLASTIQUE ASPHALTÉ: Utiliser du ciment plastique asphalté qui est conforme à ASTM D4586 Type I ou II. • RÉSISTANCE AUX VENTS / SCELLEMENT À LA MAIN: Ces bardeaux offrent un scellant thermique spécial qui colle fermement les bardeaux ensemble après application lorsque exposés au soleil et aux températures chaudes. Les bardeaux installés en automne ou en hiver peuvent ne pas sceller avant le printemps suivant. Si les bardeaux sont endommagés par les vents avant le scellement ou qu’ils ne sont pas exposés à des températures de surface adéquates, ou si l’auto-scellant est sale, les bardeaux peuvent ne jamais se sceller. Le manquement à sceller dans de telles circonstances résulte de la nature même des bardeaux autoadhésifs et non pas d’un vice de fabrication. Si des bardeaux doivent être appliqués durant des périodes de FROID PROLONGÉ ou dans des endroits où la poussière dans l’air peut être anticipée avant le scellement, les bardeaux DOIVENT être scellés à la main. Voir les instructions de Clouage / Scellement à la main. • APPLICATIONS AUX MANSARDES ET AUX PENTES FORTES: Pour des pentes de toiture de plus de 1750mm/m (21po par pied, le bardeau doit être scellé à la main. Ne PAS utiliser sur des murs verticaux. • PELLICULE DE DÉGAGEMENT: Les bandes de pellicule de plastique sont présentes tant au verso ou à l’endos de chaque bardeau. Les bandes de film sont destinées à empêcher les bardeaux de s’agglutiner les uns aux autres lorsqu’ils sont groupés par lot. Ne pas retirer la bande de pellicule avant ou durant l’application. • AÉRATION DE BÂTIMENT: Pour une durée de vie optimale du bardeau et pour aider à prévenir la croissance de moisissure, toutes les structures du toit doivent avoir suffisamment de ventilation pour prévenir l’emprisonnement d’air vicié humide derrière le platelage de toit. La ventilation doit être conçue pour répondre ou dépasser les exigences actuelles des normes minimales F.H.A/H.U.D ou celles associées au code local de construction. Remarque: Une surface de ventilation libre minimale de 1m2 par 150m2 (1pi2 par 150pi2) de surface de plafond est requise. Lorsque les évents sont situés aux avant-toits et près du faîte (dans une configuration bien équilibrée) pour un débit d’air maximum, la ventilation peut être réduite à 1m2 par 300m2 (1pi2 par 300pi2). • MÉTAL EXPOSÉ: Peindre toutes les surfaces en métal exposées (solin, évents, etc.) avec de la peinture pour accessoires ShingleMatchMC GAF appariée pour une meilleure apparence. • REMARQUE: Noter que toutes ces illustrations ne sont pas dessinées à l’échelle. 2. INSTALLING UNDERLAYMENT INSTALANDO LA CAPA BASE INSTALLATION DE LA MEMBRANE DE PROTECTION UNDERLAYMENT: FOR ROOF SLOPES 2:12 TO LESS THAN 4:12 Application of eave flashing: At eaves and where ice dams can be expected, use one layer of GAF Leak Barrier. Eave flashing must not overhang the eave edge by more than 1/4" (6mm) and should extend 24" (610mm) beyond the inside wall line. Where ice dams or debris dams are not expected, install 2 plies of GAF Roof Deck Protection. Application of underlayment: Completely cover the deck with two layers of GAF Roof Deck Protection as shown. Use only enough nails to hold underlayment in place until covered by shingles. CAPA BASE: PARA TECHOS CON PENDIENTES DE 2:12 A MENOS DE 4:12 Aplicación de vierteaguas para aleros: En los aleros y donde se pueda esperar la presencia de estancamientos de hielo, use una Capa de Barrera de Filtraciones de GAF. El vierteaguas para aleros no debe sobresalir el borde del techo más de 1/4" (6mm) y extenderse 24" (610mm) más allá de la línea interior de la pared. Donde no se esperen estancamientos de hielo o escombros, instale 2 pliegues de Protección de Plataformas Base de Techos de GAF. Aplicación de capa base: Cubra completamente la plataforma base con dos capas de Protección de Plataformas Base de Techos de GAF como se muestra. Use solamente la cantidad suficiente de clavos como para sostener la capa base en su lugar hasta que la haya cubierto con las tejas. MEMBRANE DE PROTECTION: POUR PENTE DE TOIT DE 2:12 À MOINS DE 4:12 Application de solin d’avant-toit: Au niveau des avant-toits et aux endroits où les accumulations de glace peuvent survenir, veuillez utiliser une couche Pare-Fuite de GAF. Le solin d’avant-toit ne doit pas surplomber le rebord de l’avant-toit de plus de 1/4po (6mm) et doit s’étendre à plus de 24po (610mm) au-delà de la ligne du mur intérieur. Lorsque vous n’anticipez pas d’accumulation de glace ou de débris, veuillez installer 2 couches de Protection de Platelage de Toit GAF. Application d’une membrane de protection: Recouvrir complètement la plateforme du toit avec deux couches protection de platelage de toit GAF, tel que spécifié ci-contre. Utiliser suffisamment de clous pour maintenir en place la membrane de protection jusqu’à ce qu’elle soit recouverte de bardeaux. Sheathing Revestimento Voligeage B rta m fboier a u t C la e Pla e n d GGAAFF lag ó i late ecc osddee AF t P o eG de Pr Tech d n tio ras de tec AF ier te arr ra Go F Pro Toit G B A t de eak on e G F L era C ite d A G arr -Fu B are P tec Along rake, put non-corroding metal drip edge on top of GAF Roof Deck Protection. A lo largo del alero, coloque borde de goteo de metal inoxidable encima de la Protección de la Cubierta de Techo de GAF. of o FR GA ro kP c De n tio ase Au long de l’inclinaison, mettre un larmier en métal inoxydable sur le dessus de la Protection de Platelage de Toit GAF. Along eaves, put GAF Leak Barrier on top of non-corrosive metal drip edge. A lo largo de los aleros, coloque la Barrera Contra Goteras de GAF sobre el borde de goteo de metal inoxidable. Exposure will vary depending on GAF Underlayment used. Follow application instructions on selected underlayment for proper exposure. La exposición variará en función de la Capa Base de GAF utilizada. Siga las instrucciones de aplicación en la capa base seleccionada para una exposición adecuada. Not more than 1/4" (6 mm) roof overhang Au long des avant-toits, mettre du Pare-Fuite de GAF sur le dessus du larmier en métal inoxydable. No más que 1/4" (6 mm) techo sobresale por encima de Pas plus que 6 mm (1/4 po) le surplomb de toit Le pureau peut varier selon la Membrane de Protection GAF utilisée. Suivre les instructions d’application sur les membranes de protection sélectionnées pour le pureau adéquat. 4. UNDERLAYMENT: FOR ROOF SLOPES 4:12 OR MORE Application of eave flashing: At eaves and where ice dams can be expected, use one layer of GAF Leak Barrier. Eave flashing must extend 24" (610mm) beyond the inside wall line. Application of underlayment: Cover deck with one layer of GAF Roof Deck Protection installed without wrinkles. Use only enough nails to hold underlayment in place until covered by shingles. CAPA BASE: PARA TECHOS CON PENDIENTES DE 4:12 O MÁS Aplicación de vierteaguas para aleros: En los aleros y donde se pueda esperar la presencia de estancamientos de hielo, use una Capa de Barrera de Filtraciones de GAF. El vierteaguas para aleros extenderse 24" (610mm) más allá de la línea interior de la pared. Aplicación de capa base: Cubra la plataforma base con una capa de capa base de GAF instalada sin arrugas. Use solamente la cantidad suficiente de clavos como para sostener la capa base en su lugar hasta que la haya cubierto con las tejas. MEMBRANE DE PROTECTION: FOR ROOF PENTES DE 4:12 OU PLUS Application de solin d’avant-toit: Au niveau des avant-toits et aux endroits où les accumulations de glace peuvent survenir, veuillez utiliser une couche Pare-Fuite de GAF. Le solin d’avant-toit doit s’étendre de 24po (610mm) au-delà de la ligne du mur intérieur. Application d’une membrane de protection: Couvrir le platelage avec une couche de Protection de Platelage de Toit GAF installée sans plissement. Utiliser suffisamment de clous pour maintenir en place la membrane de protection jusqu’à ce qu’elle soit recouverte de bardeaux. Along rake, put non-corroding metal drip edge on top of GAF Roof Deck Protection. A lo largo del alero, coloque borde de goteo de metal inoxidable encima de la protección de Plataforma Base del Techo de GAF. Au long de l’inclinaison, mettre un larmier en métal inoxydable sur le dessus de la protection de Platelage de Toit GAF. 4" (102mm) minimum vertical lap 2" (51mm) minimum horizontal lap Solape horizontal mínimo de 2" (51mm) Chevauchement horizontal minimum de 51mm (2po) Sheathing Revestimento Voligeage n Start at either rake tio and lay sine either direction Ba ec rot ma r P o f eck lata fD eP F oo F d age R GA F ión de GA latel c GA de c P e s s t e r e Pro Techo tion d on rrie Ba ltraci c AF e k de t i F a F e A Pro Toit G de FL eG GA rrera ite d de Ba re-Fu Pa Solape vertical mínimo de 4" (102mm) Chevauchement vertical minimum de 102mm (4po) Along eaves, put GAF Leak Barrier on top of non-corrosive metal drip edge. A lo largo de los aleros, coloque la Barrera de Filtraciones de GAF sobre el borde de goteo de metal inoxidable. Au long des avant-toits, mettre du Pare-Fuite GAF sur le dessus du larmier en métal inoxydable. Not more than 1/4" (6mm) roof overhang No más que 1/4" (6mm) techo sobresale por encima de INSTALLING STARTER STRIP SHINGLES INSTALACIÓN DE TEJAS DE HILADA INICIAL INSTALLATION DES BARDEAUX DE BANDE DE DÉPART Pas plus que 6mm (1/4 po) le surplomb de toit STARTER COURSE Use GAF starter strip shingles along the eaves and rake. Apply as shown. NOTE: GAF starter strip shingles are recommended at the rakes for best performance and required for enhanced warranty coverage on certain products (see limited warranties for details). Refer to application instructions for the selected starter strip shingles. HILADA INICIAL Use tejas de hilera inicial de GAF en los aleros. Aplicar como se muestra las inclinaciones. NOTA: Se recomienda usar tejas de hilera inicial de GAF en las inclinaciones para mejor rendimiento y se requiere para cobertura de la garantía contra el viento en ciertos productos (consulte la garantía limitada para detalles). Siga las instrucciones de aplicación de tejas de hilada inicial. RANG DE DÉPART Utiliser les bardeaux de bande de départ de GAF le long des avant-toits et inclinaison. Appliquer tel qu’indiqué. REMARQUE: Les bardeaux de bande de départ GAF sont recommandés aux inclinaisons pour une meilleure performance et sont requis pour une couverture de garantie accrue contre les vents sur certains produits (voir la garantie limitée pour les détails). Suivre les instructions d’application des bardeaux de bande de départ. For maximum wind resistance along rakes, install any GAF Starter Strip shingles which contain sealant or cement shingles to underlayment and each other in a 4" (102mm) width of asphalt plastic cement. Para máxima resistencia al viento a lo largo de las inclinaciones, instale cualquier teja de Hilada Inicial de GAF con conteniendo sellador o cemente las tejas a la capa base y entre sí en un ancho de 4" (102mm) de cemento plástico asfáltico. Pour une résistance maximale contre les vents le long des inclinaisons, installer des bardeaux de Bande de Départ GAF avec scellant ou coller les bardeaux à la membrane de protection et l’un à l’autre dans une largeur de ciment plastique asphalté de 4po (102mm). F es ent ym acion a l r r e t nd e Fil GAF d FU GA rrera ite de Ba re-Fu Pa 5" m) 7m (12 Overlap eave edge starter strip at least 3" (76mm). Traslape la hilada inicial del borde de alero por lo menos 3" (76mm). Chevaucher la bande de départ de le rebord de l’avant-toit par au moins 76mm (3po). de GA Nail approximately 1-1/2" – 3" (38 – 76mm) above the butt edge of the shingle. Clave aproximadamente a 1-1/2" – 3" (38 – 76mm) por encima del borde de empalme de la teja. Clouer à 38 – 76mm (1-1/2 à 3po) en haut du rebord du bardeau. Non-corroding metal drip edge Borde de goteo de metal inoxidable Larmier en Métal Inoxydable Place starter strip shingles 1/4" – 3/4" (6 – 19mm) over eave and rake edges to provide drip edge. Coloque las tejas de hilada inicial a 1/4" – 3/4" (6 – 19mm) sobre los bordes de alero e inclinación para proporcion r borde de goteo. Placer le bardeau à 6 – 19mm (1/4 à 3/4po) sur les rebords de l’avant-toit et de l’inclinaison pour fournir un larmier. 5. THIRD COURSE TERCERA HILADA TROISIÈME RANG Trim 11" (279mm) from rake end of first shingle. Recorte 11" (279mm) del borde de inclinación de la primera teja. F GA de nt s e e ym cion ra erla F nd e Filt A U G d F GA rrera ite de Fu Ba ree Pa urs Co rso urs rd er Cu e Co i h T erc ièm T rois T Découper à 279mm (11po) du bout du premier bardeau. " 11 mm) 9 (27 " 6 m) 2m rse (15 t cou 1s 4TH COURSE AND REMAINING Strike a chalk line about every 6 courses to check parallel alignment with eaves. 4TA. HILADA Y RESTANTES Trace una línea de tiza aproximadamente cada 6 hiladas para controlar la alineación paralela con los aleros. 4ÈME RANG ET LES RANGS RESTANTS Tracer une ligne de craie à environ tous les 6 rangs pour vérifier l’alignement en parallèle avec les avant-toits. AF eG d nt nes me lay tracio r e F nd e Fil GA d FU GA rrera ite de Fu Ba rePa Trim 17" (432mm) from rake end of first shingle. Continue with whole shingles. Repeat the 1st - 4th course instructions on the remaining courses, starting the fifth course with a full shingle. Recorte 17" (432mm) del lado que va al borde en la primera teja. Continúe con tejas completas. Repita de la 1ra a la 4ta instrucciones de hilada en las hiladas restantes, comenzando la quinta hilada con una teja completa. e urs Co urso ours h t c c r Fouuarto rième C uat Q " 17 mm) 2 Découper à 432mm (17po) de la fin de râteau de premier bardeau. Continuer avec des bardeaux entiers. Répéter les instructions du 1er au 4ème rang sur les rangs restants, en commençant au cinquième rang avec un bardeau entier. (43 11"mm) e 9 rs (27 cou 2nd 6" mm) 2 se (15 cour 1st 7. INSTALLING ROOF ACCESSORIES AND DETAILS INSTALACIÓN DE ACCESORIOS Y DETALLES DE TECHO INSTALLATION DES PRODUITS ROOF ACCESSORIES ET DÉTAILS VENTILATION Install GAF ventilation products for optimal shingle life. See General Instructions and the “Through Ventilation” section. Follow the application instructions for the selected ventilation products. VENTILACIÓN Instale productos de ventilación de GAF para una óptima vida útil de la teja. Consulte las Instrucciones Generales y la sección “A Través de la Ventilación”. Siga las instrucciones de aplicación de los productos de ventilación seleccionados. VENTILATION Installer des produits de ventilation GAF pour une durée de vie optimale. Voir les Instructions Générales dans la section «Aération de Bâtiment». Suivre les instructions d’application pour les produits de ventilation sélectionnés. RIDGE CAP SHINGLES Install GAF Ridge Cap Shingles following the application instructions shown on the GAF Ridge Cap Shingle wrapper. Position laps away from prevailing wind direction. TEJAS DE CUMBRERA Instale las Tejas de Cumbrera de GAF siguiendo las instrucciones de aplicación que figuran en el envoltorio de las Teja de Cumbrera de GAF. Coloque los solapes lejos de la dirección del viento predominante. BARDEAUX DE FAÎTAGE Installer des Bardeaux de Faîtage de GAF suivre les instructions d’installation montrées sur l’emballage des Bardeau de Faîtage de GAF. Positionner les chevauchements loin de direction des vents dominants. WALL FLASHING (Sloped Roof to Wall) VIERTEAGUAS DE PARED (Techo en Pendiente hacia la Pared) SOLINS MURAUX (de Toit en Pente à Mur) GAF Underlayment Capa Base de GAF Membrane de Protection GAF El vierteaguas de metal (Clavado a la Solin en métal (Cloué au platelage et NON PAS plataforma base, NO a la pared vertical) au mur vertical) s’étend à 5po (127mm) se extiende hacia arriba por la pared au minimum du mur). Cover metal flashing with 5" (127 mm). cut shingle. Do NOT nail shingle, install with asphaltic plastic cement. Cubra el vierteaguas de metal Sheathing Sheathing Siding con tejas cortadas. NO clave Tinglado Revestimento Revestimento las tejas, instale con cemento Parement Voligeage Voligeage plástico asfáltico. Recouvrir le solin en métal avec un bardeau coupé. NE PAS clouer le bardeau, l’installer avec du ciment plastique asphalté. Metal flashing (Nailed to the deck, NOT to the vertical wall) extend up wall at least 5" (127mm). Extend GAF Leak Barrier at least 5" (127mm) up wall. Extienda la Barrera Para Goteras de GAF por al menos 5" (127 mm) hasta la pared. Étendre du Pare-Fuite GAF à 5po (127mm) au minimum sur le mur. 2 nails per step flashing 2 clavos por vierteaguas escalonado 2 clous par noquet Extend GAF Leak Barrier at least 5" (127mm) up wall. Extienda la barrera para goteras de GAF por al menos 5" (127 mm) hasta la pared. Étendre du Pare-Fuite GAF à 5po (127mm) au minimum sur le mur. Place metal step flashing just upslope from exposed edge of shingle and extend 5" (127mm) over underlying shingle and 5" (127mm) up the vertical wall. Coloque tapajuntas metálico de paso sólo expuso orilla de tablilla y extiende 5" (127 mm) sobre tablilla fundamental y 5" (127 mm) arriba la pared vertical. Placer le clignotement métallique d'étape juste a exposé le bord de bardeau et étend 5po (127mm) sur le bardeau fondamental et 5po (127mm) sur le mur vertical. Step flashing pieces overlap each other 2" (51mm) Las piezas de vierteaguas escalonado se traslapan entre si 2" (51mm) Les pièces de noquet se chevauchent l’une l’autre de 51mm (2po) Siding/cladding must be at least 2" (51mm) above the roof surface and covering flashing at least 2" (51mm). El revestimiento/recubrimiento debe ser de al menos 2" (51mm) por encima de la superficie del techo y cubrir el vierteaguas por lo menos 2" (51mm). Le recouvrement / bardage doit maintenir 2po (51mm) au-dessus de la surface du toit et couvrir le solin au minimum de 2po (51mm). 8. PRECAUTIONARY NOTES 1. These shingles are fiberglass, self-sealing asphalt shingles. Because of the natural characteristics of the high-quality waterproofing material used, these shingles will be stiff in cold weather and flexible in hot weather. 2. These shingles are particularly tough and may require additional effort to trim to fit on the roof. Curved blade utility knives are more effective than straight blade utility knives in cutting these shingles. Using a circular saw equipped with carbide-tipped blades is also effective. 3. When using FeltBuster™ High-Traction Synthetic Roofing Felt as underlayment, it MUST be installed over one layer of VersaShield® Fire-Resistant Roof Deck Protection in order to maintain a Class A fire rating for GAF asphalt shingles. 4. Regardless of the tool used, always wear proper protective gear such as gloves, eye protection, etc. In situations where dust or fumes are generated, e.g., cutting shingles with a power saw, appropriate respiratory protection is recommended. Please refer to the SDS for further information and follow all safety procedures. Use tools carefully to prevent personal injury when working with these products. 5. Handle carefully. Shingles can easily be broken in cold weather or their edges damaged in hot weather. Do not drop bundles on edge or on other bundles to separate shingles. Do not load bundles across a hip or ridge. Do not bend bundles over shoulder for carrying. Premium shingles with heavier weight may cause cracks at sharp bend points. 6. Store on flat surface in a covered, ventilated area-maximum temperature 110°F (43°C). Do not store near steam pipes, radiators, etc., or in sunlight. 7. Do not store double stacked pallets on a long – term basis. If double stacking is required for short periods, use slip sheets of 1/2" (13mm) plywood cut to the pallet size to minimize damage. Long-term double stacked storage, especially in hot weather, can result in possible sticking, staining, and distortion of the shingles. IMPORTANT: Repair leaks promptly to avoid adverse effects, including mold growth. RE-ROOFING If old asphalt shingles are to remain in place, nail down or cut away all loose, curled or lifted shingles and replace with new, and just before applying the new roofing, sweep the surface clean of all loose debris. Since any irregularities may show through the new shingles, be sure the underlying shingles provide a smooth surface. Fasteners must be long enough to penetrate the wood deck at least 3/4" (19mm) or just through plywood. Follow above instructions for application. NOTE: Shingles can be applied over wood shingles if the surface can be made smooth enough. This may include cutting back old shingles at eaves and rakes, installing new wood edging strips as needed, and the use of beveled wood strips. Install #30 underlayment to maintain Class A rating. For technical support, call 1-800-766-3411 or visit our website at gaf.com. NOTAS DE PRECAUCIÓN 1. Estas tejas son tejas asfálticas autosellantes de fibra de vidrio. Debido a las características naturales del material impermeable de alta calidad utilizado, estas tejas serán duras en climas fríos y flexibles en climas cálidos. 2. Estas tejas son particularmente duras y pueden requerir un esfuerzo adicional en el recorte para encajarlas al techo. Los cuchillos utilitarios de hoja curva son más efectivos que los cuchillos utilitarios de hoja recta para cortar estas tejas. También es efectivo usar una sierra circular equipada con hojas con puntas de carburo. 3. Cuando utilice el Fieltro Sintético De Alta Tracción FeltBuster™ Para Techos como capa base, DEBE instalarse sobre una capa de Protección de la Cubierta del Techo Ignífuga VersaShield® con el fin de mantener una clasificación Clase A contra incendios para las tejas asfálticas GAF. 4. Independientemente de la herramienta utilizada, siempre use la vestimenta apropiada, por ejemplo, guantes, protección para los ojos, etc. En situaciones donde se genere polvo o humo, por ejemplo, al cortar las tejas con una sierra eléctrica, se recomienda utilizar la protección respiratoria apropiada. Consulte las SDS para obtener más información y siga todos los procedimientos de seguridad.Utilice las herramientas cuidadosamente para prevenir las lesiones personales cuando trabaje con estos productos. 5. Manipule con cuidado. Las tejas pueden romperse fácilmente en climas fríos o sus bordes pueden dañarse en climas cálidos. No arroje los manojos sobre el borde o encima de otros manojos para separar las tejas. No cargue los manojos sobre un caballete o borde. No doble los manojos sobre los hombros para transportarlos. El peso superior puede causar grietas en los puntos de pliegue afilados. 6. Almacene en un área cubierta y ventilada – temperatura máxima 110°F (43°C). No almacene cerca de tuberías de vapor, radiadores, etc., o a la luz del sol. 7. No almacene pálets de apilado doble en períodos largos de tiempo. Si se requiere apilado doble durante períodos breves, es preciso utilizar láminas deslizantes de 1/2" (13mm) de madera terciada cortadas al tamaño del pálet para minimizar los daños. El almacenamiento de apilado doble a largo plazo, especialmente en climas cálidos, puede resultar en posible pegado, manchado y distorsión de las tejas. IMPORTANTE: Repare las filtraciones rápidamente para evitar efectos adversos, incluyendo el crecimiento de moho. RE-TECHADO Si es preciso que las viejas tejas asfálticas permanezcan en su lugar, clave o corte cualquier teja suelta, curvada o levantada y reemplácela con una nueva, y justo antes de aplicar el nuevo techo, barra la superficie hasta dejarla libre de cualesquiera residuos sueltos. Dado que cualquier irregularidad podría notarse a través de las nuevas tejas, asegúrese que las tejas subyacentes tengan una superficie lisa. Los sujetadores deben tener el largo suficiente como para penetrar la plataforma base de madera por lo menos 3/4" (19mm) o a través de la madera terciada. Siga el resto de las instrucciones detalladas arriba para la aplicación. NOTA: Las tejas pueden ser aplicadas sobre tejas de madera si la superficie puede ser suficientemente alisada. Esto puede incluir cortar las tejas viejas en los aleros e inclinaciones e instalar nuevos bordes de madera según sea necesario y el uso de hiladas de madera biseladas. Instale capa base #30 para mantener la calificación de Clase A. Para soporte técnico, llame al 1-800-766-3411 o visite nuestro sitio Web en es.gaf.com. REMARQUES DE PRÉCAUTION 1. Ces bardeaux sont en fibre de verre et sont des bardeaux auto-scellants. En raison des caractéristiques naturelles du matériau imperméabilisant de haute qualité utilisé, ces bardeaux seront rigides en température froide et flexibles en température élevée. 2. Ces bardeaux sont particulièrement résistants et ils pourraient nécessiter des efforts additionnels pour les découper pour ajuster au toit. Des couteaux utilitaires à lame incurvée sont plus efficaces que des couteaux utilitaires à lame droite pour la découpe de ces bardeaux. Il peut aussi être très efficace d’utiliser une scie circulaire munie d’une lame à pointe au carbure. 3. Lors de l’utilisation de Feutre À Toiture Synthétique Adhérent FeltBusterMC comme membrane de protection, DOIT être installé sur une couche de Protection de Platelage de Toit Résistant au Feu VersaShieldMD afin de maintenir une cote de résistance au feu de Classe A pour les bardeaux d’asphalte GAF. 4. Sans égard à l’outil utilisé, toujours porter des vêtements de protection appropriés, c’est à dire des gants, des protections oculaires, etc. Dans des situations où des émanations ou de la poussière sont produites, comme de couper des bardeaux avec une scie électrique, une protection respiratoire appropriée est recommandée. Veuillez vous référer à la fiche signalétique de données de produit pour plus d’information et conformez-vous à toutes les procédures de données. Utiliser vos outils de manière sécuritaire pour prévenir toute blessure personnelle lors de travaux avec ces produits. 5. Manipule con cuidado. Las tejas pueden romperse fácilmente en climas fríos o sus bordes pueden dañarse en climas cálidos. No arroje los manojos sobre el borde o encima de otros manojos para separar las tejas. No cargue los manojos sobre un caballete o borde. No doble los manojos sobre los hombros para transportarlos. Las tejas de calidad superior con mayor peso pueden causar grietas en los puntos de pliegue afilados. 6. Entreposer sur une surface plane, dans un endroit couvert et ventilé – à une température maximale de 43°C (110°F). Ne pas entreposer près de conduites de vapeur, du chauffage, etc.,ou au soleil. 7. Ne pas ranger des palettes empilées en double pour une longue période. Si un empilage en double est requis pour de courtes périodes, il est nécessaire de glisser un contreplaqué de 13mm (1/2po) découpé à la taille des palettes entre les palettes pour minimiser les dommages. Le rangement à long terme en empilage en double, spécialement en température chaude, peut résulter possiblement en collement, distorsion ou en tache sur les bardeaux. IMPORTANT: Réparez les fuites prestement afin d’éviter les effets néfastes tels que la formation de moisissure. RÉFECTION DE TOITURE Si des vieux bardeaux d’asphalte doivent demeurer en place, clouer ou couper tout bardeau lâche, incurvé ou soulevé et remplacer avec du neuf, et juste avant d’appliquer le nouveau recouvrement, balayer la surface pour qu’elle soit libre de tout débris. Puisque toute irrégularité va paraître au travers des nouveaux bardeaux, assurez-vous que les bardeaux sous-jacents offrent une surface lisse. Les fixations doivent être suffisamment longues pour pénétrer le platelage de toit d’au moins 19mm (3/4po) ou juste au travers du contreplaqué. Suivre les instructions ci-dessous pour l’application. REMARQUE: Les bardeaux peuvent être installés sur des bardeaux de bois si la surface peut être suffisamment aplanie. Ceci peut nécessiter la taille des vieux bardeaux aux avant-toits et aux inclinaisons ainsi que l’installation de nouvelles plates-bandes en bois, au besoin, et l’utilisation de bandes en bois biseautées. Installez une membrane de protection #30 pour maintenir une cote de Classe A. Pour du soutien technique, appeler au 1-800-766-3411 ou visiter notre site Web au fr gaf.ca ©2014 GAF 7/14 12.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

GAF 0448737 Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para