Transcripción de documentos
ENL 6 HP
Instructions for installation and operation
english
Instruciones de instalación y de servicio
español
Instructions de montage et de service
français
Instruções de instalação e de serviço
More Than Air. Answers.
Online answers: http://www.ingersollrandproducts.com
português
C.C.N.: 80442916
REV.: C
DATE: DECEMBER 2013
Safety instructions
Please check whether or not these instructions correspond to the device type!
Please adhere to all advice given in these operating instructions. They include basic information which needs to be
observed during installation, operation and maintenance. Therefore, it is vital for the technician and the responsible
operator /skilled personnel to read these operating instructions prior to installation, start-up and maintenance. The
operating instructions must be accessible at all times at the place of application of the ENL 6 HP.
In addition to these operating instructions, local and national regulations need to be observed, if required.
Make sure that the ENL 6 HP. is operated only within the permissible limit values indicated on the type plate. Any deviation involves a risk for persons and materials, and may result in malfunction and service failures.
If you have any queries regarding these installation and operating instructions, please contact Ingersoll Rand.
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
• Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact with non-insulated
components carrying supply voltage.
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• Service measures must only be undertaken when the system is deactivated!
• All types of electrical work must be carried out by authorised and qualified personnel only.
Further safety advice:
• For installation and operation, the national regulations and safety codes in force must also be adhered to.
• Do not use the ENL 6 HP in hazardous areas.
• Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular to conical screw
joints.
• The ENL 6 HP will only function when voltage is applied.
• Do not use the test button for permanent drainage!
• Only use genuine spare parts! This is imperative to ensure perfect functioning.
Additional advice:
• During installation, use the spanner flat at the feed pipe (width across flat 36) as a back rest.
2
http://www.ingersollrandproducts.com
ENL 6 HP
Caution!
Malfunctions in the application!
Through incorrect installation and insufficient maintenance, the ENL can malfunction. Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
• Fail-safe condensate discharge directly optimises the compressed-air quality.
• To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with
the case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.
Proper use
• The ENL is an electronically level-controlled condensate drain for compressed-air plants.
• It is employed within the permissible operating parameters (see "Technical data").
• The ENL is able to drain condensate under operating pressure from the plant components virtually without compressed-air
losses.
• For its function, the ENL 6 HP requires an operating voltage and an operating pressure (see "Technical data").
• As far as the employment in plants with increased demands on the compressed-air quality is concerned (food industry, medical technology, laboratory equipment, special processes etc.), the operator must decide on measures for the monitoring of
the compressed-air quality. These have an effect on the safety of the subsequent processes and may prevent damage to
persons and plants.
• It is the task of the operator to ensure that the indicated conditions are met during the entire operating time.
• For the employment in CO2 plants, a ENL with a CO specification (ENL ... CO) must be used.
• The ENL and the condensate supply line need to be protected against frost, as otherwise the function cannot be guaranteed.
Ingersoll Rand also offers suitable products for this purpose.
Exclusion from the field of application
• The ENL as a condensate drain alone cannot guarantee a defined compressed-air quality, for this purpose, other additional
technical devices are required.
• ENL 6 HP is not suitable for use in plants carrying vacuum or atmospheric ambient pressure or in hazardous areas.
• The ENL must not be exposed to permanent direct solar or thermal radiation.
• ENL 6 HP must not be installed and operated in areas with an aggressive atmosphere.
ENL 6 HP
http://www.ingersollrandproducts.com
3
Indicaciones de seguridad
Por favor, compruebe que este manual de instrucciones corresponde realmente a su máquina.
Tenga en cuenta todas las indicaciones facilitadas en este manual. Contiene información básica importante para la
instalación, el funcionamiento y el mantenimiento de la máquina. Por este motivo es imprescindible que tanto el técnico de instalación como los operarios y personal responsable lo lean antes de realizar trabajos de instalación, puesta
en marcha y mantenimiento.
El manual de instrucciones deberá estar disponible en todo momento en el lugar de instalación del ENL 6 HP.
Además de las indicaciones contenidas en el manual, deberán respetarse las normativas vigentes locales y nacionales que correspondan.
Asegúrese de que el ENL 6 HP solamente se pone en marcha dentro de los valores límite admisibles, indicados en
la placa identificativa. De otra manera, podrían ocasionarse daños a personas y objetos, así como averías.
Si tiene alguna dificultad para entender el contenido del manual o quiere hacer alguna consulta, le rogamos que se
ponga en contacto con Ingersoll Rand.
Peligro!
¡Aire comprimido!
Un golpe de aire comprimido que escapa repentinamente o por componentes de la máquina que salgan
disparados por su efecto puede suponer peligro de graves lesiones o muerte.
Medidas preventivas:
• No sobrepasar la presión máx. de funcionamiento (ver placa identificativa)
• Realice los trabajos de mantenimiento siempre con la máquina despresurizada.
• Utilice solamente materiales resistentes a la presión para la instalación.
• Apretar bien la conducción de alimentación. Conducción de salida: manguera de presión corta fijada a una tubería resistente
a la presión.
• Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido.
¡Peligro!
¡Corriente eléctrica!
El contacto con componentes sometidos a tensión y sin aislamiento acarrea peligro de sufrir descargas
eléctricas que deriven en heridas o muerte.
Medidas preventivas:
• Al realizar la instalación eléctrica, respete todas las normativas vigentes (por ejemplo, la VDE 0100 / IEC 60364).
• Realice siempre los trabajos de mantenimiento con la máquina desconectada de la red eléctrica.
• Los trabajos eléctricos deberán dejarse en manos de personal autorizado y cualificado.
Otras indicaciones de seguridad:
• Durante la instalación y el funcionamiento deberán respetarse igualmente las normativas nacionales de seguridad vigentes.
• No utilizar el ENL 6 HP en zonas con peligro de explosión.
• Evite los momentos de apriete excesivos al atornillar las conducciones de alimentación. Esto deberá tenerse en cuenta especialmente en el caso de atornilladuras cónicas.
• El ENL 6 HP sólo podrá funcionar con corriente.
• No utilizar la tecla de test para la evacuación continua de agua.
• Utilice exclusivamente recambios originales. Sólo así quedará garantizado el buen funcionamiento del aparato.
Indicaciones adicionales:
• Para el montaje de la alimentación use llaves (SW36) para sujetar.
4
http://www.ingersollrandproducts.com
ENL 6 HP
¡Precaución!
¡Mal funcionamiento!
Una instalación incorrecta y la falta de mantenimiento pueden provocar que el ENL funcione mal.
El condensado no evacuado puede provocar daños en las instalaciones y en los procesos de producción.
Medidas preventivas:
• Una evacuación segura del condensado optimiza la calidad del aire comprimido de manera directa.
• Tenga en cuenta los puntos siguientes para prevenir daños y paradas en la producción:
• Respeto del uso apropiado y de los parámetros de servicio del ENL teniendo en cuenta el campo de aplicación de cada
caso (véase capítulo “Uso apropiado”)
• Observación estricta de las indicaciones de instalación y servicio facilitadas en este manual.
• Mantenimiento regular y control del ENL acorde a las indicaciones del manual.
Uso apropiado
• El ENL es un purgador de condensados regulado electrónicamente según el nivel para instalaciones de aire comprimido.
• Su funcionamiento deberá producirse siempre teniendo en cuenta los parámetros de servicio (ver datos técnicos).
• El ENL es capaz de evacuar el condensado bajo presión de servicio y sin producir apenas pérdidas de presión.
• El ENL 6 HP necesita para su funcionamiento una corriente y una presión concretas (ver datos técnicos).
• En aquellas aplicaciones en las que se exige un nivel de calidad de aire comprimido más alto (industria de la alimentación,
técnica médica, laboratorios, procesos especiales, etc.), el usuario deberá tomar medidas para la vigilancia de dicha calidad.
Esas medidas influyen en la seguridad de los procesos sucesivos y pueden evitar daños a personas e instalaciones.
• Será responsabilidad del usuario garantizar que se cumplan estas condiciones durante todo el tiempo de funcionamiento.
• En instalaciones de CO2 deberán instalarse unidades ENL con la especificación CO (ENL .. CO).
• El ENL y su conducción de alimentación deberán estar protegidos contra congelación, ya que de lo contrario no podrá garantizarse su buen funcionamiento.
Ingersoll Rand le ofrece productos adecuados para este fin.
Campos de aplicación incorrectos
• El ENL no puede garantizar por sí solo como purgador de condensados una calidad de aire comprimido concreta. Para ello
serán necesarios otros equipos técnicos.
• El ENL 6 HP i no es adecuado para su aplicación en el campo del vacío ni en plantas que funcionen a presión atmosférica
ni en zonas Ex.
• El ENL no deberá exponerse a la radiación solar continua ni directa, ni tampoco a la acción de fuentes de calor.
• El ENL 6 HP no debe instalarse ni funcionar en zonas con atmósferas agresivas.
ENL 6 HP
http://www.ingersollrandproducts.com
5
Consignes de sécurité
Vérifiez que cette notice corresponde bien au modèle d'appareil en votre possession.
Respectez toutes les consignes données dans ce mode d'emploi. Il contient des informations fondamentales, à respecter lors de l'installation, de l'utilisation et de la maintenance. C'est pourquoi, il est impératif que ce mode d'emploi
soit lu avant l'installation, la mise en service et la maintenance, par l'installateur ainsi que par l'exploitant et le personnel qualifié.
Le mode d'emploi doit être disponible et accessible à tout moment sur le lieu d'utilisation du ENL 6 HP .
En plus de ce mode d'emploi, il faut respecter les éventuelles prescriptions locales ou nationales.
Assurez-vous que le ENL 6 HP . ne soit utilisé qu'au sein des valeurs limites admissibles et mentionnées sur la plaque
signalétique. Dans le cas contraire, il peut présenter un risque pour les personnes et le matériel, voire nuire au bon
fonctionnement de l'installation ou générer des perturbations.
Si certains points ne sont pas clairs ou si vous avez des questions au sujet de ces instructions de montage et de service, n'hésitez pas à contacter la société Ingersoll Rand.
Danger !
Air comprimé !
Tout contact avec de l'air comprimé s'échappant rapidement ou de façon brutale ou tout contact avec des
parties de l'installation présentant un risque d'éclatement peut causer de graves blessures ou entraîner la mort.
Mesures préventives :
• Ne pas dépasser la pression de service maximale (voir plaque signalétique).
• Dépressuriser le purgeur avant toute intervention d'entretien ou de maintenance.
• N'utiliser que du matériel d'installation résistant à la pression.
• La conduite d'amenée doit toujours être réalisée en tuyauterie rigide et fixe. Conduite d'évacuation : flexible de faible longueur, fixé et relié à une tuyauterie, tous deux résistant à la pression.
• Veillez à ce qu'aucune personne ni objet ne risque d'être touché par le condensat ou l'air comprimé qui s'échappe.
Danger !
Tension électrique !
Tout contact avec des éléments non isolés et sous tension présente un risque de choc électrique pouvant
provoquer des blessures ou entraîner la mort.
Mesures préventives :
• Lors de la réalisation de l'installation électrique, respecter toutes les prescriptions en vigueur (p. ex. VDE 0100 / IEC 60364).
• Avant toute intervention d'entretien ou de maintenance, mettre le purgeur HORS TENSION.
• Toute intervention électrique doit être réalisée exclusivement par un personnel qualifié et habilité.
Autres consignes de sécurité :
• Lors de l'installation et de l'utilisation, il faut également respecter les directives et consignes de sécurité en vigueur dans le
pays en question.
• Ne pas utiliser le ENL 6 HP dans les atmosphères explosibles.
• Éviter les serrages trop importants au niveau des raccords de la conduite d'amenée Ceci est valable en particulier pour les
raccords à filetage conique.
• Le ENL 6 HP n'est opérationnel que s'il est sous tension (alimentation électrique assurée).
• Ne pas utiliser le bouton Test pour l'évacuation permanente du condensat.
• Utiliser exclusivement des pièces de rechange d'origine. Seul le respect scrupuleux des consignes données peut garantir le
parfait fonctionnement de l'appareil.
Consignes supplémentaires :
• Lors du montage, utiliser le méplat pour clé au niveau de l'arrivée (36 mm) pour maintenir le purgeur pendant le serrage.
6
http://www.ingersollrandproducts.com
ENL 6 HP
Prudence !
Dysfonctionnements au niveau de l'utilisation !
En cas d'installation incorrecte et de maintenance insuffisante, des dysfonctionnements peuvent apparaître
au niveau du ENL.
Tout condensat non évacué risque d'endommager les installations et de porter atteinte aux processus de
fabrication.
Mesures préventives :
• Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualité de l'air comprimé.
• Pour éviter tout endommagement et tout arrêt de production, il est impératif de respecter les consignes suivantes :
•
•
Respecter scrupuleusement les instructions pour une utilisation conforme à l’usage prévu et les paramètres de
fonctionnement du ENL dans le contexte de son utilisation (consulter à cet effet le chapitre „Utilisation
conforme à l’usage prévu“).
Respecter scrupuleusement toutes les instructions d'installation et d'utilisation communiquées dans cette notice.
• Respecter scrupuleusement la périodicité de maintenance et de contrôle du ENL selon les indications de ce
manuel d'utilisation.
Utilisation conforme à l'emploi prév
• Le ENL est un purgeur de condensat à régulation électronique de niveau pour les installations de production et distribution
d'air comprimé.
• L'utilisation s'effectue dans le respect des paramètres de fonctionnement admissibles (voir caractéristiques techniques).
• Le ENL permet d'évacuer le condensat du réseau de distribution sous pression (pression de service) et ce, pratiquement
sans perte de charge.
• Pour son fonctionnement, le ENL requiert une tension d'alimentation électrique et une pression de service (voir caractéristiques techniques).
• Lors d'une utilisation dans des installations soumises à des exigences plus poussées quant à la qualité de l'air comprimé
(industrie alimentaire, techniques médicales, équipements de laboratoires, processus spéciaux, etc.), l'exploitant est tenu
de prendre des mesures pour la surveillance de la qualité de l'air comprimé. Ces mesures ont une influence directe sur la
sécurité des processus en aval et permettent ainsi d'éviter les dommages corporels et l'endommagement des installations.
• Il incombe à l'exploitant d'assurer les conditions mentionnées pendant toute la durée de service.
• Pour les installations de CO2, il faut impérativement utiliser un ENL en version CO (ENL .. CO).
• Le ENL et la conduite d'amenée du condensat doivent être protégés contre le gel, sinon le fonctionnement n'est pas assuré.
Ingersoll Rand propose également des produits adéquats à cet effet.
Exclusion du domaine d'application
• En tant que purgeur de condensat, le ENL ne peut pas garantir à lui seul une qualité d'air comprimé définie ; pour ce faire, il
faut d'autres équipements techniques en plus.
• Le ENL 6 HP ne convient pas pour l'utilisation sur des installations sous vide ou fonctionnant à la pression atmosphérique
ambiante, ni pour l'utilisation dans les atmosphères explosibles.
• Le ENL ne doit pas être exposé en permanence au rayonnement direct du soleil ou à un rayonnement thermique.
• Le ENL 6 HP ne doit pas être installé ni utilisé dans les domaines exposés à une atmosphère agressive.
ENL 6 HP
http://www.ingersollrandproducts.com
7
Indicações de segurança
Favor verificar se as presentes instruções correspondem ao tipo de aparelho.
Observar todas as advertências contidas nas presentes instruções de serviço. As instruções contêm indicações básicas que deverão ser observadas durante a montagem, a operação e a manutenção. Por esses motivos, antes da
instalação, da colocação em serviço e dos trabalhos de manutenção estas instruções deverão ser lidas, sem falta,
pelo técnico de montagem, pelo cliente e pelo pessoal técnico.
As instruções deverão estar sempre disponíveis junto do local de utilização do ENL 6 HP.
Adicionalmente a estas instruções também deverão ser observadas as diretivas locais e/ou nacionais.
Ter a certeza que o ENL 6 HP só irá funcionar no âmbitos dos valores limite indicados na placa de características. Do
contrário existe perigo para pessoas e materiais, podendo ocorrer falhas de funcionamento e operacionais.
No caso de dúvidas ou de questões relacionadas com as presentes instruções de instalação e operação, favor entrar
em contato com a Ingersoll Rand.
Perigo!
Ar comprimido!
O contato com ar comprimido escapando rápida ou repentinamente ou peças que rebentam e/ou que não
estão fixadas podem provocar ferimentos graves ou a mort
Medidas a serem tomadas:
• Não ultrapassar a pressão máxima de serviço (ver placa de características).
• Trabalhos de manutenção sé devem ser executados com o sistema despressurizado.
• Só usar material de instalação à prova de pressão.
• Montar de modo fixo a tubulação de admissão. Tubulação de descarga: mangueira de pressão curta e ligada a um tubo à
prova de pressão.
• Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa.
Perigo!
Tensão da rede!
Devido ao contato com peças não isoladas e condutoras da tensão de rede existe o perigo de choque
elétrico com ferimentos e morte.
Medidas a serem tomadas:
• Na instalação elétrica deverão ser observadas todas as diretiva vigentes(p. ex. VDE 0100 / IEC 60364).
• Trabalhos de manutenção só devem ser executados com o sistema desenergizado.
• Todos os trabalhos elétricos só poderão ser efetuados por pessoal especializado e autorizado.
Outras indicações de segurança:
• Durante a instalação e a operação também devem ser observadas as diretivas e as instruções de segurança nacionais.
• Não utilizar o ENL 6 HP em áreas com perigo de explosão.
• Nas uniões roscadas de alimentação evitar forças de aperto excessivas. Isso aplica-se, especialmente, a uniões roscadas
cônicas.
• O ENL 6 HP só está operacional se tiver tensão aplicada.
• O botão de teste não deverá ser utilizado para a drenagem permanente.
• Utilizar exclusivamente peças de reposição originais. Só assim ficará garantido um funcionamento perfeito.
Indicações adicionais:
• Durante a montagem utilizar as superfícies das chaves na parte de alimentação (tamanho SW36) para segurar.
8
http://www.ingersollrandproducts.com
ENL 6 HP
Cuidado !
Mau funcionamento na aplicação!
Devido a uma instalação incorreta e a uma manutenção insuficiente é possível que ocorra o mau funciona
mento do ENL. O condensado não evacuado poderá causar danos em equipamentos e em processos de fabricação.
Medidas a serem tomadas:
• Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido.
• Para evitar danos e falhas, favor observar sem falta:
• Observação precisa da utilização de acordo com a finalidade e dos parâmetros operacionais do ENL em ligação com o
caso de utilização (ver a este respeito o capítulo „Utilização de acordo com a finalidade“)
• Observação precisa das indicações sobre instalação e operação contidas nas presentes instruções
• Manutenção regular e controle do ENL segundo as indicações contidas nas presentes instruções
Utilização de acordo com a finalidade
• O ENL é um condutor de descarga de condensado com regulação eletrônica de nível e destinado a equipamentos de ar
comprimido.
• A utilização é feita no âmbito dos parâmetros operacionais admissíveis (ver Dados Técnicos).
• O ENL pode descarregar condensado das partes do equipamento, sob pressão de serviço e praticamente sem perda de ar
comprimido.
• Para funcionar, o ENL 6 HP precisa de uma tensão de serviço e de uma pressão de serviço (ver Dados Técnicos).
• No caso de utilização em equipamentos com elevadas exigências à qualidade do ar comprimido (indústria alimentícia, eletromedicina, equipamentos de laboratório, processos especiais etc.), a entidade exploradora terá que decidir sobre medidas
relativas à monitoração da qualidade do ar comprimido. Tais medidas exercem influência sobre a segurança dos processos
seguintes, podendo evitar danos em pessoas e equipamentos.
• Cabe à entidade exploradora garantir as citadas condições durante todo o período de funcionamento.
• Para o emprego em equipamentos CO2, é necessário utilizar um ENL com a especificação CO (ENL.. CO).
• O ENL e a tubulação condutora de condensado deverão ser protegidos contra a geada, do contrário não fica assegurada a
funcionalidade.
Para essa finalidade a Ingersoll Rand oferece produtos adequados.
Exclusão do campo de aplicação
• O ENL como condutor de descarga de condensado não pode por si só garantir uma qualidade definida de ar comprimido,
pois para isso são ainda necessários outros dispositivos técnicos.
• O ENL 6 HP não é apropriado para utilização com vácuo ou em equipamentos conduzindo pressão atmosférica ambiente ou
em áreas com perigo de explosão.
• O ENL não pode estar exposto permanente à incidência direta dos raios solares ou do calor.
• O ENL 6 HP não pode ser instalado nem funcionar em áreas com uma atmosfera agressiva.
ENL 6 HP
http://www.ingersollrandproducts.com
9
Technische Daten • Datos técnicos
Caractéristiques • Dados técnicos
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1, second edition,
including Amendment 1, or a later version of the same standard incorporation the same level of
testing requirements.
Este producto se ha sometido a pruebas acorde a las exigencias de la CAN/CSA-C22.2 n.º 61010-1,
segunda edición, incluyendo el suplemento 1 o una versión posterior de la misma norma, conservando
siempre el mismo nivel de exigencia con respecto a las pruebas.
Ce produit a été testé selon les exigences de la norme CAN/CSA-C22.2 n° 61010-1, deuxième édition,
en tenant compte du complément 1 ou d'une version plus récente de la même norme, en appliquant le
même niveau d'exigences en matière de tests.
Este produto foi testado de acordo com os requisitos da CAN/CSA-C22 n° 61010-1, segunda edição,
com incorporação do aditamento 1 ou de uma versão posterior da mesma norma, levando em consideração o mesmo nível de requisitos de teste.
ENL
6
Operating pressure, min/max
Presión de servicio mín./máx.
Pression de service min/max
Pressão de serviço mín./máx.
18 ... 913 psi
(1,2 ... 63 bar)
min./max. temperature
Temperatura mín./máx.
Température min./max.
Temperatura mín./máx.
+34 ... +140 °F
(+1 ... +60 °C)
Condensate feed
Entrada condensado
Entrée du condensat
Alimentação de condensado
½ NPT / G ½
Condensate discharge (hose)
Salida de condensado (manguera)
Sortie du condensat (flexible)
Descarga do condensado (mangueira)
⅜"
Condensate
Condensado
Condensat
Condensado
oil-contaminated + oil-free
con aceite + sin aceite
Aluminio superficialmente
contendo óleo + isento de óleo
Housing
Carcasa
Corps
Gabinete
Aluminum, hard-coated
aluminio, con recubrimiento
Aluminum, avec protection anticorrosive
Alumínio hard coated
Weight (empty)
Peso (vacío)
Poids (à vide)
Peso (vazio)
2.0 lbs
(1 kg)
Max. performance for the blue climatic zone – see also Chapter "Climatic zone and performance data".
Capacidad máx. para zona climática azul – ver también capítulo “Zonas climáticas y datos de capacidad"
Capacité max. pour la zone climatique Bleu – voir aussi chapitre „Zones climatiques et Capacités“
Potência máxima para zona climática azul – ver também o capítulo "Zona climática e dados de potência"
peak compressor performance
Caudal máx. del compresor
Capacité maximale du compresseur
Potência máx. do compressor
280 scfm
7,9 m³/min
Peak refrigeration dryer performance (only with pre-separation)
Capacidad máx. del secador frigorífico (con preseparación)
Capacité maximale du sécheur frigo (seules avec pré-separation)
Potência máxima do secador a frio (só com pré-precipitação)
Peak filter performance (behind dryer)
Capacidad máx. de filtración (detrás del secador)
Capacité maximale du filtre (en aval du sécheur)
Potência máxima do filtro (após o secador)
10
http://www.ingersollrandproducts.com
560 scfm
15,8 m³/min
2800 scfm
79 m³/min
ENL 6 HP
Electrical data • Datos eléctricos
Caractéristiques electrique • Dados eléctricos
Supply voltage
Tensión de funcionamiento
Tension d'alimentation
Tensão operacional
230 / 115 / ... / 24 VAC ± 10%, 50 ... 60 Hz / 24 VDC ± 10%
see type plate / ver placa identificativa
voir plaque signalétique / vide placa de características
Power consumption
Potencia consumida
Consommation
Consumo de potência
P < 8,0 VA (W)
Fuse protection
Fusible
Fusibles
Fusível
recommanded AC: 1 A slow / stipulated DC: 1 A slow
recomend. para AC: 1 A lento / obligatorio para DC: 1 A lento
recomm. AC : 1 A fusion lente / prescrit DC : 1 A fusion lente
recom. para AC: 1 A lenta / prescrito para DC: 1 A lenta
Recommanded cable jacket diameter
Sección recomendada de la cubierta del cable
Diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro do cabo
recommended wire cross-section
Sección recomendada del conductor
Section recommandée pour les conducteurs
Seção recomendada do condutor
0.23" ... 0.34"
(ø 5,8 ... 8,5 mm)
0.03 ... 0.06 inches squared
(3 x 0,75 ... 1,5 mm²)
recommended stripping of cable jacket
Retirada recomendada de la cubierta del cable
Longueur recommandée pour le dénudage de la gaine du câble
Assentamento recomendado do invólucro do cabo
PE: ca. 2.3 inch L/N: ca. 1.96 inch
(PE: ca. 60 mm L/N: ca. 50 mm)
recommended wire stripping
Longitud recomendada de la virola del cable
Longueur recommandée pour le dénudage
Comprimento recomendado do invólucro do condutor
~ 0.24 inch
(~ 6 mm)
Connection data of the potential-free contact
Switch to load *)
Datos de conexión del contacto libre de potencial
Conmutación carga *)
Caractéristiques de raccordement du contact sans potentiel
Commuter une charge *)
Dados de conexão do contato livre de potencial
conectar carga *)
AC: max. 250 V / 1 A
DC: max. 30 V / 1 A
Connection data of the potential-free contact
Switch to low signal *)
Datos de conexión del contacto libre de potencial
Conmutación señal débil*)
Caractéristiques de raccordement du contact sans potentiel
Commuter un petit signal *)
Dados de conexão do contato livre de potencial
conectar sinal pequeno *)
min. 5 VDC / 10 mA
Protection class
Tipo de protección
Degré de protection
Classe de proteção
IP 65
VAC = V alternating current / VDC = V direct current
*) The switching of loads has the result that the properties of the contact are no longer suitable for the switching of low signals.
VAC = V alternating current (corriente alterna) / VDC = V direct current (corriente continua)
*) La conmutación de cargas tiene como consecuencia que las características del contacto ya no sean las adecuadas para
la conmutación de señales débiles.
VAC = V alternating current (Tension alternative) / VDC = V direct current (Tension continue)
*) La commutation de charges a pour conséquence que les propriétés du contact ne conviennent plus pour la commutation
de petits signaux.
VAC = V alternating current (tensão alternada) / VDC = V direct current (tensão contínua)
*) a conexão de cargas faz com que as características do contato deixem de ser apropriadas para a conexão de sinais
pequenos.
ENL 6 HP
http://www.ingersollrandproducts.com
11
Function • Funcionamiento
Functionnement • Funcionamento
english
1
4
The condensate flows through the feed
line (1) into the ENL unit and accumulates
in the container (2). A capacitive sensor
(3) continuously registers the liquid level
and passes a signal to the electronic
control as soon as the container is filled.
The pilot valve (4) is then activated and
the diaphragm (5) opens the outlet line
(6) for discharging the condensate.
When the ENL unit has been emptied,
the outlet line is closed again quickly and
tightly without wasting compressed air.
2
1
3
5
6
2
1
Ready for operation
Voltage is being applied
2
Discharge procedure
Outlet line is open
3
Malfunction
Alarm mode is activated
4
Test
Manual drainage/alarm
The test button is used for checking
correct functioning.
3
4
Switching sequence of valve in alarm mode
Secuencia de actuación de la válvula en el modo de alarma
Séquence d'activation de la vanne en mode Alarme
Sequência de ligação da válvula no modo de alarme
Pressing
Effect
Short
Manual drainage
> 1 min
Alarm mode
When the microcontroller registers a
malfunction, the device will automatically
change to the alarm mode. The switching
sequence of the valve (see illustration)
continues until the fault is cleared (automatically or through maintenance). The
red LED flashes as long as the device
is in the alarm mode.
Malfunctioning could be caused by, e.g.:
• Mistakes during installation
• Dropping below the necessary minimum pressure
• Excessive condensate quantities (overloading)
• Blocked/shut off outlet line
• Extreme amount of dirt particles
• Frozen piping
Alarm signal via potential-free contact
Mensaje de alarma a través de contacto sin potencial
Signal d'alarme délivré sur le contact sans potentiel
Sinal de alarme via contacto isento de potencial
12
http://www.ingersollrandproducts.com
If the fault is not cleared within the first
minute, a fault signal is triggered (see
illustration) which can be picked off as a
potential-free signal via the alarm relay.
ENL 6 HP
español
français
português
El condensado fluye a través de la tubería de entrada (1) al ENL y se acumula
en el depósito (2). El sensor capacitivo
de nivel (3) controla permanentemente el
nivel de llenado. Si el depósito está lleno,
el sensor emite una señal a la unidad
de pilotaje electrónico. Inmediatamente
se acciona la válvula de pilotaje (4) y la
membrana (5) abre la salida (6) para
purgar el condensado.
Amené dans le ENL par la conduite d'arrivée (1), le condensat est collecté dans
le réservoir (2). Une sonde capacitive
(3) surveille en permanence le niveau
de remplissage et envoie un signal à la
commande électronique dès que le réservoir est rempli. L'électrovanne pilote (4)
est activée et la membrane (5) ouvre la
conduite d'évacuation (6) pour l'éclusage
du condensat.
En el momento en el que el ENL esta
vacío se cierra la salida herméticamente
antes de que se produzca un escape de
aire comprimido.
Dès que le ENL est vide, la conduite
d'évacuation est à nouveau refermée
avec une parfaite étanchéité, avant même
que l'air comprimé ne puisse s'échapper.
O condensado corre através do tubo adutor (1) para dentro do ENL e acumulase
no interior da caixa (2). Um sensor que
trabalha capacitivamente (3) vai continuamente registando o nível, transmitindo
um sinal ao comando electrónico logo
que o depósito se encher de condensado. A válvula de comando piloto (4) é
accionada e o diafragma (5) abre o tubo
de descarga (6) para escoamento do
condensado.
Esvaziado o ENL, o tubo de descarga
é de novo fechado hermeticamente a
tempo para evitar perdas desnecessárias
de ar comprimido.
1
En funcionamiento El aparato
está bajo tensión eléctrica
1
Prêt à fonctionner
Tension d'alimentation présente
1
Estado de prontidão para entrar
em funcionamento Tensão aplicada
2
Procesode purga
La salida está abierta
2
Phase de purge
Conduite d'évacuation ouverte
2
Processo de descarga
Tubo de descarga está aberto
3
Perturbación
El modo „ALARMA“ está ectivado
3
Dysfonctionnement
Mode Alarme activé
3
Avaria
Modo de alarme está activado
4
Test
Purga manual/alarma
4
Test
Purge manuelle/Alarme
4
Teste
Drenagem manual/alarme
El interruptor de „TEST“ sirve para
el control del funcionamiento.
La touche Test sert à tester le
fonctionnement.
O botão de teste é utilizado para
controlar o funcionamento.
Accionamiento
Resultado
Action
Effet
Accionamento
Efeito
rápido
purga manual
brève
Purge manuelle
rápido
drenagem manual
> 1 min
modo de alarma
> 1 min
Mode Alarme
> 1 min
modo de alarme
Si el microcontrolador detecta una
perturbación en el funcionamiento, se
activa el modo de alarma. La secuencia
de actuación de la válvula dura hasta
que la causa de la perturbación haya
sido eliminada(por si misma o por un
mantenimiento). El LED rojo parpadea
durante el estado de alarma.
Posibles causas son p.ej.:
• fallos en el montaje
• la presión está por debajo de la presión
mínima indicada
• la cantidad de condensado es demasiado alta
• está taponada o cerrada la tubería de
la salida
• cantidad extrema de partículas de
suciedad
• tuberías heladas
Si la perturbación no está eliminada
dentro del primer minuto, se activa el
mensaje de la alarma (ver imágen),
que puede ser transmitida como señal
sin potencial a través del relé de alarma.
ENL 6 HP
Lorsque le microcontrôleur détecte une
anomalie, il active le mode alarme. La
séquence d'activation de la vanne (voir
figure) persiste jusqu'à ce que le problème
soit résolu (automatiquement ou par intervention de maintenance). La LED rouge
clignote pendant la fonction d'alarme.
Quando o microcontrolador verifica uma
avaria, o alarme é activado. A sequência de ligação da válvula (ver imagem)
permanece activada até se eliminar a
avaria (automaticamente ou através de
manutenção). O LED vermelho pisca
durante a função de alarme.
Causes de dysfonctionnement
possibles:
• Défaut au niveau de l'installation
• Pression minimale non atteinte
• Trop de condensat (surcharge)
• Ecoulement bouché ou obturé
• Importantes quantités d'impuretés
• Conduites gelées
Causas possíveis da avaria são p. ex.:
• erro na instalação
• pressão inferior à pressão mínima
admissível
• quantidade excessiva de condensado
(sobrecarga)
• tubo adutor entupido/passagem impedida
• quantidade excessiva de partículas de
sujidade
• tubagens geladas
Si la panne n'est pas résolue en l'espace
d'une minute, un signal d'alarme est émis
(voir figure). Un signal sans potentiel est
délivré par le relais d'alarme.
http://www.ingersollrandproducts.com
Se a falha não for eliminada durante o
primeiro minuto, o aparelho activa o sinal
de alarme (ver imagem), que poderá ser
comutado em sinal isento de potencial
através do relé do sinal.
13
Installation
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
• Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Caution!
Malfunctions in the application!
Through incorrect installation and insufficient maintenance, the ENL can malfunction. Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
• Fail-safe condensate discharge directly optimises the compressed-air quality.
• To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with the
case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.
Note:
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding the industrial safety and fire prevention at the respective place of
installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact should be avoided.
Condensate is subject to mandatory waste disposal and must be collected in suitable
containers, and disposed of or processed properly.
14
http://www.ingersollrandproducts.com
ENL 6 HP
Instalación
¡Peligro!
¡Aire comprimido!
Un golpe de aire comprimido que escapa repentinamente o por componentes de la máquina que salgan
disparados por su efecto puede suponer peligro de graves lesiones o muerte.
Medidas preventivas:
• No sobrepasar la presión máx. de funcionamiento (ver placa identificativa)
• Realice los trabajos de mantenimiento siempre con la máquina despresurizada.
• Utilice solamente materiales resistentes a la presión para la instalación.
• Apretar bien la conducción de alimentación. Conducción de salida: manguera de presión corta fijada a una tubería resistente
a la presión.
• Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido.
¡Precaución!
¡Mal funcionamiento!
Una instalación incorrecta y la falta de mantenimiento pueden provocar que el ENL funcione mal. El
condensado no evacuado puede provocar daños en las instalaciones y en los procesos de producción.
Medidas preventivas:
• Una evacuación segura del condensado optimiza la calidad del aire comprimido de manera directa.
• Tenga en cuenta los puntos siguientes para prevenir daños y paradas en la producción:
• Respeto del uso apropiado y de los parámetros de servicio del ENL teniendo en cuenta el campo de aplicación de cada
caso (véase capítulo “Uso apropiado”).
• Observación estricta de las indicaciones de instalación y servicio facilitadas en este manual.
• Mantenimiento regular y control del ENL acorde a las indicaciones del manual.
Atención:
Tenga siempre en cuenta todas las indicaciones de peligro y advertencia facilitadas.
Observe igualmente todas las normativas e indicaciones de protección en el trabajo y contra incendios allí donde se efectúe
la instalación.
Utilice únicamente herramientas y materiales adecuados y en buen estado.
No utilice detergentes agresivos ni herramientas inadecuadas, como limpiadores a alta presión.
Tenga en cuenta que el condensado puede contener componentes agresivos y dañinos para la salud. Por esa razón deberá
evitarse siempre el contacto con la piel.
El condensado es un residuo que el usuario está obligado a gestionar correctamente, recogiéndolo en recipientes adecuados
para luego eliminarlo o tratarlo.
ENL 6 HP
http://www.ingersollrandproducts.com
15
Installation
Danger !
Air comprimé !
Tout contact avec de l'air comprimé s'échappant rapidement ou de façon brutale ou tout contact avec des
parties de l'installation présentant un risque d'éclatement peut causer de graves blessures ou entraîner la mort.
Mesures préventives :
• Ne pas dépasser la pression de service maximale (voir plaque signalétique).
• Dépressuriser le purgeur avant toute intervention d'entretien ou de maintenance.
• N'utiliser que du matériel d'installation résistant à la pression.
• La conduite d'amenée doit toujours être réalisée en tuyauterie rigide et fixe. Conduite d'évacuation : flexible de faible longueur, fixé et relié à une tuyauterie, tous deux résistant à la pression.
• Veillez à ce qu'aucune personne ni objet ne risque d'être touché par le condensat ou l'air comprimé qui s'échappe.
Prudence !
Dysfonctionnements au niveau de l'utilisation !
En cas d'installation incorrecte et de maintenance insuffisante, des dysfonctionnements peuvent apparaître
au niveau du ENL.
Tout condensat non évacué risque d'endommager les installations et de porter atteinte aux processus de
fabrication.
Mesures préventives :
• Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualité de l'air comprimé.
• Pour éviter tout endommagement et tout arrêt de production, il est impératif de respecter les consignes suivantes :
• Respecter scrupuleusement les instructions pour une utilisation conforme à l’usage prévu et les paramètres de fonctionnement du ENL dans le contexte de son utilisation (consulter à cet effet le chapitre „Utilisation conforme à l’usage prévu“).
• Respecter scrupuleusement toutes les instructions d'installation et d'utilisation communiquées dans cette notice.
• Respecter scrupuleusement la périodicité de maintenance et de contrôle du ENL selon les indications de ce manuel
d'utilisation.
Remarque :
Respectez impérativement toutes les informations relatives à un danger ou à un avertissement.
Respectez également toutes les prescriptions et consignes de sécurité relatives à la protection des travailleurs et à la protection incendie en vigueur au lieu d'installation en question.
Utilisez toujours l'outillage et le matériel appropriés et en bon état.
N'utilisez aucun produit de nettoyage agressif, ni d'appareils inadaptés, par exemple les nettoyeurs haute pression.
Notez bien que les condensats peuvent contenir des composants agressifs et néfastes pour la santé. C'est pourquoi, il est
recommandé d'éviter tout contact avec la peau.
Les condensats sont soumis à la réglementation sur les déchets. Ils doivent être collectés dans des récipients appropriés,
éliminés ou recyclés.
16
http://www.ingersollrandproducts.com
ENL 6 HP
Instalação
Perigo!
Ar comprimido!
O contato com ar comprimido escapando rápida ou repentinamente ou peças que rebentam e/ou que não
estão fixadas podem provocar ferimentos graves ou a morte.
Medidas a serem tomadas:
• Não ultrapassar a pressão máxima de serviço (ver placa de características).
• Trabalhos de manutenção sé devem ser executados com o sistema despressurizado.
• Só usar material de instalação à prova de pressão.
• Montar de modo fixo a tubulação de admissão. Tubulação de descarga: mangueira de pressão curta e ligada a um tubo à
prova de pressão.
• Impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa.
Cuidado!
Mau funcionamento na aplicação!
Devido a uma instalação incorreta e a uma manutenção insuficiente é possível que ocorra o mau funcionamento do ENL.
O condensado não evacuado poderá causar danos em equipamentos e em processos de fabricação.
Medidas a serem tomadas:
• Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido.
• Para evitar danos e falhas, favor observar sem falta:
• Observação precisa da utilização de acordo com a finalidade e dos parâmetros operacionais do ENL em ligação com o
caso de utilização (ver a este respeito o capítulo „Utilização de acordo com a finalidade“)
• Observação precisa das indicações sobre instalação e operação contidas nas presentes instruções
• Manutenção regular e controle do ENL segundo as indicações contidas nas presentes instruções
Observação:
Prestar atenção, sem falta, a todas as indicações de perigo e advertências.
Observar igualmente todos os regulamentos referentes à segurança no trabalho e à proteção contra incêndios.
Só devem ser usadas ferramentas apropriadas e materiais em perfeito estado.
Não utilizar produtos de limpeza agressivos nem aparelhos inadequados, tais como equipamentos de limpeza a alta pressão.
Não esquecer que os condensados podem conter elementos agressivos e nocivos à saúde. Por isso, evitar qualquer contato
com a pele.
Condensado é um resíduo sujeito à destinação final que deverá ser recolhido em recipientes apropriados, levado à destinação
final ou tratado.
ENL 6 HP
http://www.ingersollrandproducts.com
17
Installation • Instalación
Installation • Instalação
english
1. Feed pipe and fitting at least ½"!
(internal dia > 0,51 inch)
2. No filters in feed line
3. Slope in feed line > 1%!
4. Only use ball valves!
5. Pressure: min. 12 psi or 18 psi!
(check type plate for correct pres-sure)
6. Short pressure hose!
7. For each yard of rising slope in the
outlet line, the required minimum
pressure will increase by 1.5 psi.
The rise of the outlet line must not
exceed 17 feet!
8. Collecting line min. ½ ‘’ with 1% slope
9. In the case of inflow problems, install
venting line.
wrong • no correcto
incorrect • incorrecto
correct • correcto
correct • correcto
Note:
Pressure differences!
Each condensate source must be drained
separately!
Note:
Venting!
If the feed line cannot be laid with sufficient slope, it will be necessary to install
a venting line!
Note:
Deflector area!
If drainage is to take place directly from a
line, it is advisable to arrange the piping
so that the air flow is diverted.
18
http://www.ingersollrandproducts.com
ENL 6 HP
español
français
português
1. Tubería de entrada y piezas de co_0,51
nexión mín. ½"! (diá. interior <
inch)!
2. No ponga ningun filtro en la tubería
de entrada
3. La tubería de la entrada tiene que tener
una pendiente descendente constante
>1%
4. Utilice solamente llaves de paso
esféricas
5. Presión de funcionamiento mín. 12
psi o 18 psi (lea la presión indicada
en la etiqueta de identificación)
6. Tubo a presión corto
7. Por cada metro que asciende la tubería
de salida, se incrementa la presión
mínima de funcionamiento en 1.5
psi. Subida máxima de la tubería
de salida: 17 feet
8. Tubería colectora de los condensados: mín. ½" con pendiente descendente constante 1%
9. Si existieran problemas de entrada,
instalar una tubería de ventilación.
1. Tube d'amenée, au moins ½" !
(Diametre interieur > 0,51 inch)
2. Pas de filtre sur l'amenée !
3. Pente de l'amenée >1% !
4. Utiliser uniquement des vannes à
boisseau sphérique !
5. Pression : minimum 12 ou 18 psi!
(relever la pression sur la plaque)
6. Flexible pression de faible longeur!
7. Pour chaque mètre de pente montante sur la conduite d'éVACuation, il
faut augmenter la pression minimale
requise de 1.5 psi!
Evacuation: longueur max. de la partie
montante : 17 feet !
8. Conduite collectrice :
au minimum ½" avec 1% de pente!
9. La conduite d'écoulement doit être
raccordée par un col de cygne sur la
conduite collectrice
1. Diâmetro mínimo do tubo e acessórios
adutor ½"!
_ 0,51 inch)
(diâmetro interno <
2. Não montar filtros no tubo adutor!
3. Declive de afluência >1%!
4. Só utilizar válvulas esféricas!
5. Pressão: no mínimo 12 ou 18 psi!
(Ver pressão indicada na placa
indicadora das características)
6. Tubo flexível curto!
7. Por cada metro de subida no tubo
de descarga, a pressão mínima
necessária vai aumentando em 1.5
psi!
O tubo de descarga não deve exceder
17 feet de subida!
8. Assentar tubagem colectora com
diâmetro mínimo de ½" e 1% de declive!
9. Em caso de problemas de afluência,
instalar um tubo de eVACuação do ar.
Observe:
Important :
Importante:
diferencial de presión
différences de pression!
diferenças de pressão!
Se tiene que purgar por separado cada
Chaque point de soutirage de condensat
Cada fonte de condensado terá que ser
punto de purga.
doit être purgé individuellement pour éviter
drenada separadamente!
le by-pass. Une purge continue ne serait
plus possible dans ces conditions !
Observe:
Important :
Importante:
compensación
équilibrage d'air !
evacuação do ar!
Si no hay suficiente pendiente des-
Si la pente de l'amenée n'est pas suffi-
Se o declive da afluência não for sufi-
cendente constante en la tubería de la
sante, il faut poser une conduite d'équi-
ciente, ou se houver outros problemas
entrada se tiene que montar una tubería
librage d'air !
de afluência deve montar-se um tubo
de ventilação!
de compensación.
Observe:
Important :
Importante:
separación de los condensados
chicane !
desvio!
Si se quiere purgar una tubería, es mejor,
Si la purge doit s'effectuer directement sur
Quando se pretende efectuar a drena-
si se realiza una desviación de la corrien-
la tuyauterie, il faut prévoir une chicane
gem directamente através da tubagem,
te de aire comprimido.
pour que le condensat ne soit pas entrainé
deve-se prever um desvio para a cor-
par le débit d'air comprimé !
rente de ar!
ENL 6 HP
http://www.ingersollrandproducts.com
19
Installation • Instalación
Installation • Instalação
wrong • no correcto
incorrect • incorrecto
english
correct • correcto
correct • correcto
Note:
Continuous slope
It is important to avoid water pockets when
using a pressure hose as a feed line!
Note:
Continuous slope!
Water pockets must also be avoided
when laying a feed pipe.
20
http://www.ingersollrandproducts.com
ENL 6 HP
español
français
português
Observe:
Important :
Importante:
pendiente descendente constante
pente continue !
declive contínuo!
Si se emplea como entrada un tubo
Si l'amenée est réalisée au moyen d'un
Quando se utiliza um tubo flexível de ar
flexible, se tiene que evitar que se forme
flexible, il faut éviter toute "retenue
comprimido para a afluência do conden-
un sifón.
d'eau" !
sado deve evitarse bolsas de água.
Observe:
Important :
Importante:
pendiente descendente constante
pente continue !
declive contínuo!
Si se emplea como entrada un tubo
Si l'amenée est réalisée au moyen d'une
Evitar igualmente bolsas de água quando
rígido, se tiene que evitar que se forme
tuyauterie rigide, il faut aussi éviter toute
se assenta tubos para a afluência.
un sifón.
"retenue d'eau" !
ENL 6 HP
http://www.ingersollrandproducts.com
21
Elektrical Installation
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact with non-insulated
components carrying supply voltage.
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• Service measures must only be undertaken when the system is deactivated!
• All types of electrical work must be carried out by authorised and qualified personnel only.
• At an AC supply, a reliably accessible separator must be provided close-by (e.g. power plug or switch), which
separates all current-carrying conductors
• If the potential-free contact carries voltage that is dangerous in the case of contact, a corresponding separator
must also be provided.
• The provided 24 VDC voltage must meet the requirements for protective extra-low voltages (PELV) in accordance with IEC
60364-4-41.
Note:
Between terminals KL 5 "±24V VDC" and KL 6 "±24V VDC" of the VDC devices and housings or condensate connections, there
is no galvanic isolation.
As regards tests, for example protective conductor tests in accordance with VDE 0701-0702 / IEC 85/361/CD, it must be observed that there is only a connection for the establishment of a functional earthing between the touchable conductive parts
of the device and the protective conductor base, and no protective connection capable of carrying current.
Tighten the threaded cable connection with a slightly sealing effect.
Potential-free contact
Via the potential-free contact, the alarm signal can be transmitted (i.e. to a control system). The switch-over contact can be
operated in the fail-safe mode.
For example, if supply voltage is applied and if the ENL functions trouble-free, the alarm relay is activated. The normally-open
contact (0.7-0.8) is closed.
If no supply voltage is applied or if a trouble indication occurs, the alarm relay is released. The normally-open contact is open
(alarm).
External test button (optional)
With this button, accumulated condensate can be discharged systematically via remote control. Here, the normal test-button function is additionally led out of the ENL. When the external contact is closed, the valve opens. Observe the additional instructions!
Between the protective conductor/PE connection and the piping, a potential difference is not admissible. If required,
potential equalisation in accordance with VDE 0100 / IEC 60364 must be provided for.
22
http://www.ingersollrandproducts.com
ENL 6 HP
Instalación eléctrica
¡Peligro!
¡Corriente eléctrica!
El contacto con componentes sometidos a tensión y sin aislamiento acarrea peligro de sufrir descargas
eléctricas que deriven en heridas o muerte.
Medidas preventivas:
• Al realizar la instalación eléctrica, respete todas las normativas vigentes (por ejemplo, la VDE 0100 / IEC 60364).
• Realice siempre los trabajos de mantenimiento con la máquina desconectada de la red eléctrica.
• Los trabajos eléctricos deberán dejarse en manos de personal autorizado y cualificado.
• Si la alimentación es por AC, deberá disponerse cerca un dispositivo de separación accesible (por ejemplo, una
clavija de enchufe o un interruptor) que aísle todas las conducciones eléctricas.
• Si el contacto libre de potencial es atravesado por tensiones que supongan un riesgo ante contactos fortuitos, deberá instalarse el dispositivo de aislamiento que convenga.
• La tensión disponible de 24 VDC deberá cumplir los requisitos para las bajas tensiones de funcionamiento con aislamiento
seguro (PELV) previstos en la IEC 60364-4-41.
Atención:
Entre los bornes de conexión KL 5 "±24V VDC" – KL 6 "±24V VDC" de los aparatos VDC y las carcasas o las conexiones de
condensado hay un aislamiento galvánico.
Al efectuar controles, por ejemplo de los conductores protectores acorde a la VDE 0701-0702 / IEC 85/361/CD, deberá tenerse
en cuenta que sólo existe una conexión para crear una puesta a tierra funcional entre las piezas conductoras susceptibles de
contacto y el soporte del condutor protector, pero que no hay una conexión de protección resistente a la corriente.
Apretar la atornilladura del cable de forma que hermetice ligeramente.
Contacto libre de potencial
Es posible transmitir la señal de alarma (por ejemplo, al puesto de mando) por medio del contacto libre de potencial. El contacto de conmutación puede funcionar en modo fail-safe, por ejemplo:
Si hay tensión de funcionamiento y el ENL está en marcha sin presentar averías, el relé de alarma estará activado. El contacto
(0.7 - 0.8) está cerrado.
Si no hay tensión de funcionamiento o existe un aviso de avería, el relé de alarma descargará. El contacto estará abierto
(alarma).
Tecla de test externa (opcional)
Gracias a ella puede purgarse el condensado acumulado por control remoto. La función normal de la tecla de test ist hier
zusätzlich aus dem ENL herausgeführt. Cuando el contacto externo se cierra, la válvula se abre. ¡Tenga en cuenta las indicaciones del manual adicional!
Entre el conductor protector/la conexión de PE y la red de tuberías no debe haber diferencia de potencial. En caso
necesario, deberá instalarse una conexión equipotencial acorde a la VDE 0100 / IEC 60364.
ENL 6 HP
http://www.ingersollrandproducts.com
23
Installation électrique
Danger !
Tension électrique !
Tout contact avec des éléments non isolés et sous tension présente un risque de choc électrique pouvant
provoquer des blessures ou entraîner la mort.
Mesures préventives :
• Lors de la réalisation de l'installation électrique, respecter toutes les prescriptions en vigueur (p. ex. VDE 0100 / IEC 60364).
• Avant toute intervention d'entretien ou de maintenance, mettre le purgeur HORS TENSION.
• Toute intervention électrique doit être réalisée exclusivement par un personnel qualifié et habilité.
• En cas d’alimentation en courant alternatif CA, il est impératif de prévoir à proximité un dispositif de sectionnement accessible (par ex. une fiche secteur ou un interrupteur), qui coupe tous les conducteurs véhiculant le
courant électrique.
• Si le contact sans potentiel véhicule des tensions électriques dangereuses en cas de contact, il est impératif de
prévoir un dispositif de sectionnement, comme décrit plus haut.
• La tension continue de 24 VDC mise à disposition doit répondre aux exigences pour les Très Basses Tensions de Protection (T.B.T.P.) avec séparation sécurisée par rapport à la tension secteur (PELV = Protection by Extra Low Voltage) selon la
norme IEC 60364-4-41.
Remarque :
Entre les bornes KL 5 "±24V VDC" - KL 6 "±24V VDC" des appareils VDC et le corps ou les raccords des conduites de
condensat, il n'y a pas d'isolation galvanique.
Lors des vérifications, par ex. les tests du conducteur de protection selon VDE 0701-0702 / IEC 85/361/CD, il faut veiller à ce
que – entre les éléments conducteurs et accessibles de l'appareil et le point d'appui du conducteur de protection – il n'y ait
qu'une liaison permettant de réaliser une mise à la terre fonctionnelle et non une liaison de protection capable de véhiculer
un courant.
Serrer légèrement le presse-étoupe de façon à assurer l'étanchéité.
Contact sans potentiel
Le contact sans potentiel peut être utilisé pour réaliser un report d'alarme (par exemple, vers un système de supervision ou de
télésurveillance). Le contact inverseur peut être exploité par exemple en mode fail-safe (sécurité positive) :
Si la tension de service est présente et si le ENL fonctionne normalement, le relais d'alarme est excité. Le contact de travail
(7 - 8) est fermé.
Si la tension d'alimentation n'est pas présente ou si un signal d'alarme est émis, le relais d'alarme est désexcité. Le contact de
travail est ouvert (Alarme).
Bouton Test externe (en option)
Celui-ci permet de commander à distance, au moment voulu, la purge du condensat collecté. La fonction normale du bouton
Test est ainsi reportée du ENL vers un contact externe. Lorsque ce contact est fermé, la vanne s'ouvre.
Suivre les instructions de la notice séparée !
Aucune différence de potentiel n’est admissible entre la borne PE du conducteur de protection et le réseau de
conduites. Le cas échéant, il faut prévoir une liaison équipotentielle selon VDE 0100 / IEC 60364.
24
http://www.ingersollrandproducts.com
ENL 6 HP
Instalação elétrica
Perigo!!
Tensão de rede!
Devido ao contato com peças não isoladas e condutoras da tensão de rede existe o perigo de choque
elétrico com ferimentos e morte.
Medidas a serem tomadas:
• Na instalação elétrica deverão ser observadas todas as diretiva vigentes (p.ex. VDE 0100 / IEC 60364).
• Trabalhos de manutenção só devem ser executados com o sistema desenergizado.
• Todos os trabalhos elétricos só poderão ser efetuados por pessoal especializado e autorizado.
• No caso de alimentação por AC, nas proximidades deve ser previsto um dispositivo de corte acessível (por ex. ficha
de rede ou interruptor) que possa cortar todos os condutores que conduzam corrente.
• Se o contato livre der potencial conduzir tensões perigosas ao toque, também aqui deverá ser previsto um dispositivo de corte correspondente.
• A tensão disponível de 24 VDC deverá atender os requisitos de baixas tensões funcionais com corte seguro (PELV) segundo
IEC 60364-4-41.
Observação
Entre os terminais KL 5 "±24V VDC" - KL 6 "±24V VDC" dos aparelhos VDC e o gabinete ou conexões de condensado não
existe qualquer separação galvânica.
No caso de testes, por ex. testes do condutor de proteção segundo VDE 0701-0702 / IEC 85/361/CD, prestar atenção ao fato
de que entre as peças tocáveis e condutoras do aparelho e o ponto de apoio do condutor de proteção só existe uma ligação
para estabelecimento de um aterramento de funcionamento, não havendo qualquer ligação de proteção capaz de transportar
corrente.
Apertar levemente a união roscada do cabo de modo a vedar.
Contato livre de potencial
Através do contato livre de potencial é possível transmitir o sinal de alarme (p. ex. a um posto de comando). O contato de
comutação pode ser operado, p. ex., em modo fail-safe:
Se estiver aplicada tensão de serviço e se o ENL estiver funcionando sem problemas, o relé de alarme está ativo. O contato
de trabalho (0.7 -0.8) está fechado.
Se não estiver aplicada qualquer tensão de serviço ou se houver um aviso de falha, o relé de alarme desopera. O contato de
trabalho está aberto (alarme).
Botão externo de teste(opcional)
Deste modo é possível descarregar o condensado existente mediante controle remoto. A função normal do botão de teste é
aqui executada adicionalmente a partir do ENL. Se o contato externo fechar, a válvula abre.
Observar as instruções suplementares!
Entre a conexão do condutor de proteção/PE e a rede de tubulação não é admissível qualquer diferença de potencial.
Eventualmente deverá ser prevista uma compensação de potencial segundo VDE 0100 / IEC 60364.
ENL 6 HP
http://www.ingersollrandproducts.com
25
Electrical installation • Instalación eléctrica
Installation electrique • Instalação elétrica
A
B
C
english
• It is imperative to read the permissible
mains voltage from the type plate (G)!
• Carry out installation works in accordance with VDE 0100 / IEC 60364.
• Do not install when voltage is applied.
• Lift off domed cover (A) after removing
the 4 screws (B).
H
• Take power supply board (C) out of the
domed cover (A) after removing the
screw (D).
K
• Guide cables for power supply (E)
and potential-free contact (F) through
screwed cable fittings.
F
• Terminals
VAC power supply 0.0 L
0.1 N
0.2 PE
D
24 VDC power supply +24 VDC (0V)
0V (+24 VDC)
E
0
1. .1
1 .0
2
• Connect potential-free contact (F) to
terminals 0.6 - 0.7 (fail safe) or 0.7 - 0.8
(open during malfunction).
• Pull cable (E + F) tight and screw down
cable fittings.
• Screw power supply board (G) with
screw (D) into domed cover (A)
• Plug ribbon cable (H) into control PCB
(K)
VAC - voltages
0.8
normally open
0.7
common
0.6
normally closed
• If the individual wires have not been
screwed into the plug, they should be
attached as follows: 1.0 = brown
1.1 = blue
2.0 = black
• Put on top of cover (A) and tighten the
4 screws (B)
Please note:
0.2
PE
0.1
N
0.0
L
Earth/Ground
Neutral
Phase
The power supply board (C) is in a
reverse position (upside down) in the
domed cover (A).
During no-load operation, a voltage of up
to 36 VDC may be measured at terminals
1.0 and 1.1 (plug ribbon cable (H)).
24 VDC - voltage
26
0.8
normally open
0.7
common
0.6
normally closed
6
±24V +24 VDC (0V)
5
±24V 0V (+24 VDC)
http://www.ingersollrandproducts.com
ENL 6 HP
español
français
português
• ¡Consulte la tensión de red admisible
en la placa identificativa (G)!
• Respecter impérativement la tension
secteur admissible, mentionnée sur la
plaque signalétique (G) !
• Consultar, sem falta, na placa de
características (G) a tensão de rede
admissível!
• No realice la instalación bajo tensión.
• Réaliser les travaux d'installation conformément à VDE 0100 / IEC 60364.
• Executar os trabalhos de instalação
conforme VDE 0100 / IEC 60364.
• Desmontar la tapa de la carcasa (A)
después de soltar los 4 tornillos (B).
• Ne pas effectuer l'installation SOUS
TENSION.
• Não instalar sob tensão.
• Sacar la platina de la fuente de alimentación (C) de la tapa de la carcasa (A)
después de soltar el tornillo (D).
• Démonter le capot (A), après avoir
dévissé les 4 vis (B)
• Realice los trabajos de instalación
acorde a la VDE 0100 / IEC 60364.
• Introducir el cable de alimentación eléctrica (E) y el contacto libre de potencial
(F) a través de las guías correspondientes.
• Asignación de bornes
Alimentación eléctrica VAC 0.0 L
0,1 N
0.2 PE
Alimentación eléctrica 24 VDC
+24 VDC (0V)
0V (+24 VDC)
• Conectar el contacto libre de potencial
(F) a los bornes 0.6 - 0.7 (cerrado en
caso de avería) o 0.7 - 0.8 (abierto en
caso de avería).
• Tensar el cable (E + F) y apretar las
atornilladuras
• Retirer la carte d'alimentation (C) du
capot (A), après avoir dévissé la vis (D)
• Enfiler à travers les presse-étoupes, les
câbles pour l'alimentation électrique (E)
et le contact sans potentiel (F)
• Bornes
VAC Alimentation électrique
0.0 L
0.1 N
0.2 PE
24 VDC Alimentation électrique
+24 VDC (0V)
0V (+24 VDC)
• Raccorder le contact sans potentiel (F)
aux bornes 0.6 - 0.7 (fermé en cas de
panne) ou 0.7 - 0.8 (ouvert en cas de
panne)
• Desmontar a tampa da cobertura (A)
após soltar os 4 parafusos (B).
• Soltar o parafuso (D) e remover a placa
da fonte de alimentação (C) da tampa
de cobertura (A).
• Os cabos para a alimentação de tensão
(E) e para o contato livre de potencial (F)
deverão passar pelas uniões roscadas
de cabos.
• Atribuição dos terminais
Alimentação de tensão VAC 0.0 L
0.1 N
0.2 PE
• Ligar o contato livre de potencial (F) aos
bornes 0.6 - 0.7 (fechado em caso de
falha) ou a 0.7 - 0.8 (aberto emcaso de
falha).
• Esticar os cabos (E + F) e apertar as
uniões roscadas para cabos.
• Tendre les câbles (E + F) , puis serrer
les presse-étoupes
• Na tampa de cobertura (A), fixar a placa
da fonte de alimentação (C) mediante
o parafuso (D).
• Revisser la carte d'alimentation (C) avec
la vis (D) dans le capot (A)
• Encaixar o terminal de cabos (H) na
placa de comando (K).
• Introducir la clavija del cable (H) en la
platina de control (K).
• Enficher le câble en nappe (connecteur)
(H) sur la carte de commande (K)
• Si se han extraído por error los cordones
de la clavija, el orden para volver a
conectarlos será el siguiente:
1.0 = marrón
1.1 = azul
2.0 = negro
• Au cas où les diffèrents fils seraient
par inadvertance dissociès de la fiche,
respecter la répartition suivante:
1.0 = marron
1.1 = bleu
2.0 = noir
• Se, por engano, cada um dos condutores
tiver sido desaparafusado do terminal de
cabos, aplica-se a seguinte atribuição:
1.0 = marrom
1.1 = azul
2.0 = preto
• Colocar la tapa de la carcasa (A) y
apretar a continuación los 4 tornillos (B).
• Mettre le capot (A) en place et visser
les 4 vis (B)
• Colocar la platina de la fuente de alimentación (C) en la tapa de la carcasa
(A) apretando el tornillo (D).
Atención:
La platina de la fuente de alimentación
(C) se coloca invertida (cabeza abajo)
en la tapa de la carcasa (A).
En funcionamiento sin carga se medirá
en los bornes 1.0 y 1.1 (clavija del cable
(H)) una tensión de hasta 36 VDC.
ENL 6 HP
Important !
La carte d'alimentation (C) est à l'envers
dans le capot (A) .
A vide, on peut relever aux bornes1.0 et
1.1 (câble en nappe connecteur (H)) une
tension pouvant atteindre 36 VDC.
• Colocar a tampa da cobertura (A) e
apertar à mão os 4 parafusos (B).
Atenção!
A placa da fonte de alimentação (C) está
alojada na tampa de cobertura (A) de
cabeça para baixo.
Em operação sem carga, nos bornes
1.0 e 1.1 (terminal de cabos (H)) pode
ser medida uma tensão de até 36 VDC.
http://www.ingersollrandproducts.com
27
Supervision and maintenance
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping compressed air or
through bursting plant components or plant components which are not secured.
Measures:
• Do not exceed the maximum operating pressure (see type plate)!
• Only carry out service measures when the system is pressureless.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact with non-insulated
components carrying supply voltage.
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• Service measures must only be undertaken when the system is deactivated!
• All types of electrical work must be carried out by authorised and qualified personnel only.
Caution!
Malfunctions in the application!
Through incorrect installation and insufficient maintenance, the ENL can malfunction. Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
• Fail-safe condensate discharge directly optimises the compressed-air quality.
• To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with the
case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.
Note:
It is imperative to observe all hazard statements and warnings listed here.
Please also observe all regulations and notes regarding the industrial safety and fire prevention at the respective place of
installation.
As a matter of principle, only use suitable and appropriate tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such as high-pressure cleaners.
Please note that condensates may contain aggressive or harmful components. Therefore, skin contact should be avoided.
Condensate is subject to mandatory waste disposal and must be collected in suitable
containers, and disposed of or processed properly.
28
http://www.ingersollrandproducts.com
ENL 6 HP
Control y mantenimiento
¡Peligro!
¡Aire comprimido!
Un golpe de aire comprimido que escapa repentinamente o por componentes de la máquina que salgan
disparados por su efecto puede suponer peligro de graves lesiones o muerte.
Medidas preventivas:
• No sobrepasar la presión máx. de funcionamiento (ver placa identificativa)
• Realice los trabajos de mantenimiento siempre con la máquina despresurizada.
• Utilice solamente materiales resistentes a la presión para la instalación.
• Apretar bien la conducción de alimentación. Conducción de salida: manguera de presión corta fijada a una tubería resistente
a la presión.
• Haga lo posible para evitar que personas u objetos puedan ser alcanzados por escapes de aire comprimido.
¡Peligro!
¡Corriente eléctrica!
El contacto con componentes sometidos a tensión y sin aislamiento acarrea peligro de sufrir descargas
eléctricas que deriven en heridas o muerte.
Medidas preventivas:
• Al realizar la instalación eléctrica, respete todas las normativas vigentes (por ejemplo, la VDE 0100 / IEC 60364).
• Realice siempre los trabajos de mantenimiento con la máquina desconectada de la red eléctrica.
• Los trabajos eléctricos deberán dejarse en manos de personal autorizado y cualificado.
¡Precaución!
¡Mal funcionamiento!
Una instalación incorrecta y la falta de mantenimiento pueden provocar que el ENL funcione mal. El
condensado no evacuado puede provocar daños en las instalaciones y en los procesos de producción.
Medidas preventivas:
• Una evacuación segura del condensado optimiza la calidad del aire comprimido de manera directa.
• Tenga en cuenta los puntos siguientes para prevenir daños y paradas en la producción:
• Respeto del uso apropiado y de los parámetros de servicio del ENL teniendo en cuenta el campo de aplicación de cada
caso (véase capítulo “Uso apropiado”)
• Observación estricta de las indicaciones de instalación y servicio facilitadas en este manual.
• Mantenimiento regular y control del ENL acorde a las indicaciones del manual.
Atención:
Tenga siempre en cuenta todas las indicaciones de peligro y advertencia facilitadas.
Observe igualmente todas las normativas e indicaciones de protección en el trabajo y contra incendios allí donde se efectúe
la instalación.
Utilice únicamente herramientas y materiales adecuados y en buen estado.
No utilice detergentes agresivos ni herramientas inadecuadas, como limpiadores a alta presión.
Tenga en cuenta que el condensado puede contener componentes agresivos y dañinos para la salud. Por esa razón deberá
evitarse siempre el contacto con la piel.
El condensado es un residuo que el usuario está obligado a gestionar correctamente, recogiéndolo en recipientes adecuados
para luego eliminarlo o tratarlo.
ENL 6 HP
http://www.ingersollrandproducts.com
29
Contrôle et maintenance
Danger !
Air comprimé !
Tout contact avec de l'air comprimé s'échappant rapidement ou de façon brutale ou tout contact avec des
parties de l'installation présentant un risque d'éclatement peut causer de graves blessures ou entraîner la mort.
Mesures préventives :
• Ne pas dépasser la pression de service maximale (voir plaque signalétique).
• Dépressuriser le purgeur avant toute intervention d'entretien ou de maintenance.
• N'utiliser que du matériel d'installation résistant à la pression.
• La conduite d'amenée doit toujours être réalisée en tuyauterie rigide et fixe. Conduite d'évacuation : flexible de faible longueur, fixé et relié à une tuyauterie, tous deux résistant à la pression.
• Veillez à ce qu'aucune personne ni objet ne risque d'être touché par le condensat ou l'air comprimé qui s'échappe.
Danger !
Tension électrique !
Tout contact avec des éléments non isolés et sous tension présente un risque de choc électrique pouvant
provoquer des blessures ou entraîner la mort.
Mesures préventives :
• Lors de la réalisation de l'installation électrique, respecter toutes les prescriptions en vigueur (p. ex. VDE 0100 / IEC 60364).
• Avant toute intervention d'entretien ou de maintenance, mettre le purgeur HORS TENSION.
• Toute intervention électrique doit être réalisée exclusivement par un personnel qualifié et habilité.
Prudence !
Dysfonctionnements au niveau de l'utilisation !
En cas d'installation incorrecte et de maintenance insuffisante, des dysfonctionnements peuvent apparaître
au niveau du ENL.
Tout condensat non évacué risque d'endommager les installations et de porter atteinte aux processus de
fabrication.
Mesures préventives :
• Le bon fonctionnement de la purge des condensats permet une optimisation directe de la qualité de l'air comprimé.
• Pour éviter tout endommagement et tout arrêt de production, il est impératif de respecter les consignes suivantes :
• Respecter scrupuleusement les instructions pour une utilisation conforme à l’usage prévu et les paramètres de
fonctionnement du ENL dans le contexte de son utilisation (consulter à cet effet le chapitre „Utilisation conforme à l’usage
prévu“).
• Respecter scrupuleusement toutes les instructions d'installation et d'utilisation communiquées dans cette notice.
• Respecter scrupuleusement la périodicité de maintenance et de contrôle du ENL selon les indications de ce manuel
d'utilisation.
Remarque :
Respectez impérativement toutes les informations relatives à un danger ou à un avertissement.
Respectez également toutes les prescriptions et consignes de sécurité relatives à la protection des travailleurs et à la protection incendie en vigueur au lieu d'installation en question.
Utilisez toujours l'outillage et le matériel appropriés et en bon état.
N'utilisez aucun produit de nettoyage agressif, ni d'appareils inadaptés, par exemple les nettoyeurs haute pression.
Notez bien que les condensats peuvent contenir des composants agressifs et néfastes pour la santé. C'est pourquoi, il est
recommandé d'éviter tout contact avec la peau.
Les condensats sont soumis à la réglementation sur les déchets. Ils doivent être collectés dans des récipients appropriés,
éliminés ou recyclés.
30
http://www.ingersollrandproducts.com
ENL 6 HP
Controle e manutenção
Perigo!
Ar comprimido!
O contato com ar comprimido escapando rápida ou repentinamente ou peças que rebentam e/ou que não
estão fixadas podem provocar ferimentos graves ou a morte.
Medidas a serem tomadas:
• Tão ultrapassar a pressão máxima de serviço (ver placa de características).
• Trabalhos de manutenção sé devem ser executados com o sistema despressurizado.
• Só usar material de instalação à prova de pressão.
• Montar de modo fixo a tubulação de admissão. Tubulação de descarga: mangueira de pressão curta e ligada a um tubo à
prova de pressão.
• impedir que pessoas ou objetos possam ser atingidos pelo condensado ou pelo ar comprimido que escapa.
Perigo!
Tensão de rede!
Devido ao contato com peças não isoladas e condutoras da tensão de rede existe o perigo de choque
elétrico com ferimentos e morte.
Medidas a serem tomadas:
• Na instalação elétrica deverão ser observadas todas as diretiva vigentes(p. ex. VDE 0100 / IEC 60364).
• Trabalhos de manutenção só devem ser executados com o sistema desenergizado.
• Todos os trabalhos elétricos só poderão ser efetuados por pessoal especializado e autorizado.
Cuidado!
Mau funcionamento na aplicação!
Devido a uma instalação incorreta e a uma manutenção insuficiente é possível que ocorra o mau funcio
namento do ENL. O condensado não evacuado poderá causar danos em equipamentos e em proces
sos de fabricação.
Medidas a serem tomadas:
• Uma descarga perfeita do condensado otimiza diretamente a qualidade do ar comprimido.
• Para evitar danos e falhas, favor observar sem falta:
• Observação precisa da utilização de acordo com a finalidade e dos parâmetros operacionais do ENL em ligação com o
caso de utilização (ver a este respeito o capítulo „Utilização de acordo com a finalidade“)
• Observação precisa das indicações sobre instalação e operação contidas nas presentes instruções
• Manutenção regular e controle do ENL segundo as indicações contidas nas presentes instruções.
Observação:
Prestar atenção, sem falta, a todas as indicações de perigo e advertências.
Observar igualmente todos os regulamentos referentes à segurança no trabalho e à proteção contra incêndios.
Só devem ser usadas ferramentas apropriadas e materiais em perfeito estado.
Não utilizar produtos de limpeza agressivos nem aparelhos inadequados, tais como equipamentos de limpeza a alta pressão.
Não esquecer que os condensados podem conter elementos agressivos e nocivos à saúde. Por isso, evitar qualquer contato
com a pele.
Condensado é um resíduo sujeito à destinação final que deverá ser recolhido em recipientes apropriados, levado à destinação
final ou tratado.
ENL 6 HP
http://www.ingersollrandproducts.com
31
Maintenance • Mantenimiento • Entretien • Manutenção
Maintenance recommendation:
• Housing and valve should be cleaned
once a year.
• Replace wearing parts once a year.
Set of wearing parts ( x )
ENL 6 HP
38446126
Functional test of ENL device:
• Briefly press test button 2 sec.
• Valve opens for condensate discharge.
Checking of alarm signal:
• Shut off condensate inflow.
• Press test button for at least 1 minute.
• Red LED flashes (after 1 minute).
• Alarm signal is being relayed.
32
http://www.ingersollrandproducts.com
ENL 6 HP
Recomendaciones para el
mantenimiento:
• anualmente limpie la carcasa y la válvula
• anualmente cambie los elementos de
desgaste
Kit de piezas de desgaste (x)
ENL 6 HP
Recommandations pour l'entretien :
Recomendação de manutenção:
• 1 fois par an, nettoyer le boîtier et la
soupape
• limpar todos os anos a caixa e a válvula
• 1 fois par an, remplacer les pièces
d'usure
• limpar todos os anos a caixa e a válvula
Kit de pièces d'usure ( x )
Jogo de peças de desgaste ( x )
ENL 6 HP
38446126
ENL 6 HP
38446126
38446126
Control del funcionamiento del
ENL:
Test de fonctionnement du ENL
Testar o funcionamento do ENL:
• Accione el pulsador de TEST durante
unos segundos.
• Pression brève sur la touche Test 2 sec.
• Premir brevemente o botão de teste.
• La soupape s'ouvre pour la purge
• A válvula abre-se para escoamento do
condensado.
• La válvula abre para la evacuación del
condensado.
Vérification du signal d'alarme :
Control del mensaje de alarma:
• Presser la touche Test pendant 1 min.
au moins
• cierre la entrada de los condensados
• accione el pulsador de „TEST“ durante
1 minuto
• Obturer l'arrivée de condensat
• La LED rouge clignote (après 1 min.)
• Le signal d'alarme est activé
• el LED rojo parpadea (después de 1 min)
Controlar o sinal de alarme:
• Fechar a afluência de condensado.
• Premir pelo menos 1 minuto o botão de
teste.
• LED vermelho pisca (passado 1 min).
• O sinal de alarme é activado.
• la señal de alarma se conecta
ENL 6 HP
http://www.ingersollrandproducts.com
33
Trouble shooting • Busqueda de fallos
Recherche de panne • Localização de erros
english
No LED lighting up
Possible causes:
Ningún LED está iluminado
• Power supply faulty
• Power supply board defective
• Control PCB defective
Aucune LED n'est allumée
Todos os LEDs apagados
Pressing of test button,
but no condensate discharge
El interruptor de „TEST“ está pulsado,
pero el condensado
no se evacua
La touche Test est actionnée,
mais sans purge du condensat
Botão de teste premido, mas não há
descarga de produto de condensação
Condensate discharge only when test
button is being pressed
- Check voltage on type plate.
- Check voltage on power supply board
at terminals 0.0, 0.1, 0.2.
- Check 24 VDC voltage on control PCB
at terminals 1.0, 1.1
(without load up to 36 VDC may be
measured)
- Check plug connection/ribbon cable
Possible causes:
• Feed and/or outlet line shut off or
blocked
• Worn parts
• Control PCB defective
• Solenoid valve defective
- Check feed line and outlet line
- Replace worn parts
- Check if valve opens audibly
(press test button several times)
- Check 24 VDC voltage on control PCB
at terminals 3.0, 3.1, 3.2 (without load
up to 36 VDC may be measured)
Possible causes:
•
•
•
•
Feed line with insufficient slope
Excessive condensate quantities
Sensor tube extremely dirty
Dropping below necessary minimum
pressure
Descarga de produto de condensação
só com o botão de teste premido
-
Lay feed line with adequate slope
Install venting line
Clean sensor tube
Ensure minimum pressure, otherwise
install low-pressure or vacuum condensate drain
Device keeps blowing off air
Possible causes:
El aparato está abierto
constantemente
• Control air line blocked
• Worn parts
L'appareil refoule de l'air en
permanence
- Clean entire valve unit
- Replace worn parts
- Clean sensor tube
Evacuación del condensado soló si
está pulsado el interruptor de „TEST“
Purge du condensat uniquement
si la touche Test est actionnée
Aparelho deixa continuamente
escapar ar
34
http://www.ingersollrandproducts.com
ENL 6 HP
español
français
português
Posibles causas:
Origines possibles :
Causas possíveis:
• tensión de la entrada no correcta
• fuente de alimentación defectuosa
• circuito de pilotaje defectuoso
• Défaut d'alimentation électrique
• Carte d'alimentation défectueuse
• Carte de commande défectueuse
• erro na alimentação de tensão
• fonte de alimentação defeituosa
• placa de comando defeituosa
- lea la tensión de la etiqueta identificativa
- compruebe la tensión de la fuente de
alimentación en los bornes 0.0 - 0.1 0.2
- compruebe la tensión de 24 VCC del
circuito de pilotaje en los bornes 1.0 1.1 (sin carga hasta 36 VCC)
- compruebe la conexión del conector
del cable plano
- Relever la tension sur la plaque
- Vérifier la tension sur la carte d'alimentation, aux bornes 0.0 - 0.1 - 0.2.
- Vérifier la tension de 24 VDC sur la
carte de commande, aux bornes 1.0 1.1 (mesurable sans charge jusqu'à 36
VDC)
- Vérifier liaison enfichable/câble en
nappe
- ver na placa indicadora a tensão correcta
- verificar tensão dos bornes 0.0 - 0.1 0.2 na placa de alimentação a partir da
rede
- verificar tensão 24 VDC dos bornes
1.0 - 1.1 na placa de comando (sem
carga, pode ser medida até 36 VDC)
- verificar conexão da ficha/cabo em fita
Posibles causas:
Origines possibles :
Causas possíveis:
• la tubería de la entrada y/o la tu-bería
de la salida están obstruidas
• desgaste
• la platina de pilotaje está defectuosa
• la válvula de pilotaje está defectuosa
• Conduites d'arrivée et/ou d'évacuation
obturées ou bouchées
• Usure
• Carte de commande défectueuse
• Electrovanne défectueuse
• tubo de afluência e/ou descarga fechado ou entupido
• desgaste
• placa de comando defeituosa
• válvula magnética defeituosa
- controle la tuberías
- cambie las piezas de desgaste
- compruebe si puede oir la válvula
actuando (pulse el interruptor „TEST“
varias veces)
- compruebe la tensión de 24 VCC del
circuito de pilotaje en los bornes 1.0 1.1 (sin carga hasta 36 VCC)
- Contrôler l'arrivée et l'évacuation
- Remplacer les pièces d'usure
- Vérifier si l'ouverture de la soupape
est perceptible (Presser plusieurs fois
la touche Test)
- Vérifier les 24 VDC sur la carte de
commande, aux bornes 3.0 - 3.1 - 3.2.
(mesurable sans charge jusqu'à 36
VDC)
- controlar tubos de afluência e descarga
- substituir peças de desgaste
- verificar se a válvula se abre audivelmente (premir repetidamente o botão
de teste)
- verificar tensão 24 VDC dos bornes 3.0
- 3.1 -3.2 na placa de comando (sem
carga, pode ser medida até 36 VDC)
Posibles causas:
Origines possibles :
Causas possíveis:
• la tubería de la entrada no tiene pendiente descendente constante
• hay demasiada cantidad de condensado
• el sensor está muy sucio
• la red no tiene la presión mínima
• Conduite d'arrivée avec pente insuffisante
• Trop de condensat produit
• Tube de sonde fortement encrassé
• Pression minimale non atteinte
•
•
•
•
tubo adutor sem declive suficiente
quantidade excessiva de condensado
tubo-sensor extremamente sujo
pressão inferior à pressão mínima
necessária
- Réaliser l'arrivée avec une pente
- Installer une conduite d'équilibrage
d'air
- Nettoyer le tube de sonde
- Assurer la pression minimale ou installer un purgeur Low Pressure ou à
dépression
-
assentar tubo com declive adequado
instalar um desvio para desvio do ar
limpar o tubo-sensor
assegurar pressão mínima ou instalar
um escoadouro de baixa pressão ou
de vácuo.
Posibles causas:osibles causas:
Origines possibles :
Causas possíveis:
• los conductos de pilotaje estan obstruidos
• desgaste
• Conduite d'équilibrage d'air bouchée
• Usure
• tubo de controlo de ar entupido
• desgaste
- Nettoyer entièrement le module soupape
- Remplacer les pièces d'usure
- Nettoyer le tube sonde
- limpar a unidade completa da válvula
- substituir peças de desgaste
- limpar tubo-sensor
- instale la tubería con pendiente descendente constante
- instale una tubería de compensación
- limpie el tubo del sensor
- asegure la presión mínima necesaria
o instale un ENL para baja presión o
para vacío
- limpie todo el módulo de la válvula
- cambie las piezas de desgaste
- limpie el tubo sensor
ENL 6 HP
http://www.ingersollrandproducts.com
35
Components • Despieze • Nomenclature des pièces • Componentes
15
18
16
17
19
14
20
13
12
21
22
11
12
10
29
8
30
7
6
32a
45
32b
24
26
31
46
23
25
28
9
47
48 49
27
33
34
5
3
4
35
39
36
40
37
2
38
1
36
43
http://www.ingersollrandproducts.com
42
41
44
ENL 6 HP
english
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
Housing
Dust cap R ½
Earthing screw
O-ring 4 x 1,5
Sensor tube
O-ring 31,42 x 2,62
Fixing screw
O-ring 34,59 x 2,62
Bottom of cover
Cover mounting element
Control PCB
Pan-head screw M3 x 6
Cord packing 315 x 2
Top cover
Pan-head screw M3 x 10
Sealing ring for PG9
Clamping fixture for PG9
Dust protection disk PG9
Clamping bolt for PG9
Dust cap
Power supply board
O-ring 5,5 x 1,5
Control-air cover
Pan-head screw M4 x 30
Plug sealing panel
Valve connector
Fixing screw
Solenoid
Countersunk screw M4x25
O-ring 11,1 x 1,78
Flange
O-ring 6,07 x 1,3
Core guide pipe
Oval ring 21,8 x1,5 x 2,5
Valve core
Conical spring
Diaphragm cap
O-ring 5,5 x 1,5
Pressure spring for
diaphragm
40 Diaphragm
41 Diaphragm seat
42 Pan-head screw M5 x 12
43 O-ring 5 x 1,5
44 Hose connector ø13
45 Clamping bolt for PG7
46 Clamping ring for PG7
47 Sealing ring for PG7
48 Hexagon nut M5
49 Washer
ENL 6 HP
español
français
Carcasa
Tapón de cierre
Tornillo masa
Junta tórica 4 x 1,5
Tubo sensor
Junta tórica 31,42 x 2,62
Tornillo de fijación
Junta tórica 34,59 x 2,62
Tapa inferior
Fijación tapa inferior
Platina de pilotaje
Tornillo M3 x 6
Junta tórica 2 x 315
Tapa superior
Tornillo M3 x 10
Junta para PG9
Brida para PG9
Disco protección polvo
Tornillo para PG9
Tapón de cierre
Platina fuente de
alimentación
22 Junta tórica 5,5 x 1,5
23 Tapa del aire de pilotaje
24 Tornillo M4 x 30
25 Junta para conector
26 Conector válvula
27 Tornillo de fijación
28 Bobina
29 Tornillo M4 x 25
30 Junta tórica 11,1 x 1,78
31 Brida
32 Junta tórica 6,07 x 1,3
33 Tubo guia núcleo
34 Junta ovalada
21,8x1,5x2,5
35 Núcleo de la válvula
36 Muelle para el núcleo
37 Tapa membrana
38 Junta tórica 5,5 x 1,5
39 Muelle para la membrana
40 Membrana
41 Asiento membrana
42 Tornillo M5 x 12
43 Junta tórica 5 x 1,5
44 Tubo conexión ø13
45 Tornillo para PG7
46 Brida para PG7
47 Junta para PG7
48 Tuerca hexagonal M5
49 Arandela
1 Boîtier
2 Obturateur R ½
3 Vis de masse
4 Joint torique 4 x 1,5
5 Tube de sonde
6 Joint torique 31,42 x 2,62
7 Vis de fixation
8 Joint torique 34,59 x 2,62
9 Partie inf. du boîtier élec.
10 Fixation du boîtier élec.
11 Carte de commande
12 Vis à tête cyl. M3 x 6
13 Joint boîtier élec. 315 x 2
14 Partie sup. du boîtier élec.
15 Vis à tête cyl. M3 x 10
16 Bague d'étanchéité
17 Cage serre-câble
18 Joint antipoussière
19 Vis de pression
20 Obturateur
21 Carte d'alimentation
22 Joint torique 5,5 x 1,5
23 Couvercle air de comm.
24 Vis à tête cyl. M4 x 30
25 Joint du connecteur
26 Connecteur soupape
27 Vis de fixation
28 Bobine magnétique
29 Vis à tête fraisée
30 Joint torique 11,1 x 1,78
31 Bride
32 Joint torique 6,07 x 1,3
33 Tube guide noyau
34 Joint ovale
35 Noyau de vanne
36 Ressort conique
37 Couvercle de membrane
38 Joint torique 5,5 x 1,5
39 Ressort de membrane
40 Membrane
41 Siège de la membrane
42 Vis à tête cyl. M5 x 12
43 Joint torique 5 x 1,5
44 Douille pour flexible ø13
45 Vis de pression
46 Bague de compression
47 Bague d'étanchéité
48 Ecrou hexagonal M5
49 Rondelle
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
http://www.ingersollrandproducts.com
português
1
2
3
4
5
6
7
8
9
Caixa
Bujão R ½
Parafuso de ligação à terra
Anel em „o“ 4 x 1,5
Tubo-sensor
Anel em „o“ 31,42x2,62
Parafuso de fixação
Anel em „o“ 34,59x2,62
Parte de baixo da
cobertura
10 Elemento de fixação da
cobertura
11 Placa de comando
12 Parafuso de cabeça
lenticular M3 x 6
13 Empanque de cordão
2 x 315
14 Parte de cima da cobertura
15 Parafuso de cabeça
lenticular M3 x 10
16 Anel de vedação
17 Capa de aperto para PG9
18 Disco protector contra pó
19 Parafuso de pressão
20 Bujão
21 Placa de alimentação a
partir da rede
22 Anel em „o“ 5,5 x 1,5
23 Tampa do ar de controlo
24 Parafuso de cabeça
lenticular M4 x 30
25 Empanque de ficha
26 Ligador de válvula
27 Parafuso de fixação
28 Bobina inductora
29 Parafuso de cabeça
escareada M4 x 25
30 Anel em „o“ 11,1 x 1,78
31 Flange
32 Anel em „o“ 6,07 x 1,3
33 Tubo de guia do núcleo
34 Anel oval 21,8 x 1,5 x 2,5
35 Núcleo de válvula
36 Mola cónica em fio
metálico
37 Tampa do diafragma
38 5,5 x 1,5
39 Mola de pressão para
diafragma
40 Diafragma
41 Assento do diafragma
42 Parafuso de cabeça
lenticular M5 x 12
43 Anel em „o“ 5 x 1,5
44 Conector de tubo de
borracha ø13
45 Parafuso de pressão
46 Anel de aperto para PG7
47 Anel de vedação
48 Porca sextavada M5
49 Arruela
37
Spare part kits • Kits de pièces de rechange
Kits de pièces de rechange • Conjunto de peças sobressalentes
english
ENL 6
order ref. • Referencia
No de com. • N.º de encom.
38
Content • Contenido • Contenuto • Conteúdo
Available sets of spare parts
38446126
22, 32, 34, 35, 36, 38, 39, 40, 43
Set of wearing parts
38448270
22, 23, 24, 29, 32, 37, 38, 41, 42, 43, 44, 48, 49
Valve mounting parts
38448288
22, 23, 24, 28 - 44, 48, 49
Valve unit, complete
38448296
4, 6, 8, 13, 22, 30, 32, 34, 38, 43
Set of seals
38448304
1, 3, 4, 6, 10, 22, 43
Housing, complete
38448312
11, 12
PCB „control“
38448320
21, 12
PCB „power supply“ (230 VAC / 24 VDC)
38448338
21, 12
PCB „power supply“ (115 VAC / 24 VDC)
38448346
13 - 20
Top of cover, complete
http://www.ingersollrandproducts.com
ENL 6 HP
español
français
português
Kits disponibles
Kits de pièces de rechange
disponibles
Jogos disponíveis de peças
sobressalentes
Kit de desgaste
Kit de pièces d'usure
Conjunto de peças de desgaste
Piezas para la válvula
Pièces fixation vanne
Peças desmontáveis da válvula
Válvula completa
Module électrovanne, complet
Unidade de válvula, completa
Kit de juntas
Jeu de joints d'étanchéité
Jogo de peças de vedação
Carcasa completa
Boîtier, complet
Caixa, completa
Platina de pilotaje
Carte "Commande"
Placa „comando“
Fuente de alimentación
(230 VCA / 24 VCC)
Fuente de alimentación
(115 VCA / 24 VCC)
Carte "Alim." (230 VAC / 24 VDC)
Placa „alimentação a partir da rede“
(230 VAC / 24 VDC)
Placa „alimentação a partir da rede“
(115 VAC / 24 VDC)
Tapa superior completa
Partie sup. du boîtier élec., compl.
ENL 6 HP
Carte "Alim." (115 VAC / 24 VDC)
http://www.ingersollrandproducts.com
Parte de cima da cobertura, complet
39
Dimensions • Dimensiones • Dimensions • Dimensões
G½
(½" NPT)
G 3⁄8 - i
(3⁄8" NPT)
di = 10 - 13
(dia = ½")
mm (inch)
40
http://www.ingersollrandproducts.com
ENL 6 HP
ENL 6 HP
http://www.ingersollrandproducts.com
41
42
http://www.ingersollrandproducts.com
ENL 6 HP
ENL 6 HP
http://www.ingersollrandproducts.com
43
North America
800-E Beaty Street
Davidson, NC 28036
USA
Subject to technical changes without prior notice; errors not excluded.
Salvo modificaciones técnicas o errores.
Sous réserve de modifications techniques et d'erreurs typographiques.
Salvo alterações técnicas e erros.
enl6_hp_manual_en-es-fr-pt_usa_01-2943_1312_v00
Edition/Edición/Edition/Edição: 2013-12
44
http://www.ingersollrandproducts.com
ENL 6 HP