Air Vent RV26GR Instrucciones de operación

Tipo
Instrucciones de operación

Este manual también es adecuado para

WARNING: Read all warning messages and instructions
before starting installation of this fan. Failure to follow these
safety instructions can result in injury or even death. If you
need assistance in understanding these instructions or have
questions or comments, please call 1 (309) 692-6969.
ELECTRICAL HAZARDS
DANGER:
The electrical installation and wiring of this fan
must be done by a qualified electrician in accordance with all
local codes and standards, including fire-rated construction.
Failure to do the installation properly can result in fire or
even death. NOTE: A few hours of operation without appar-
ent problems does not necessarily imply that the installation
is safe.
DANGER: Do not substitute a solid state speed control for
the thermostatically controlled on-off switch that comes with
this fan. Use of a solid state speed control can result in a fire
causing injury or death.
DANGER: Watch out for existing electrical wiring and other
utility wires or pipes when selecting a location for the fan. Do
not install the fan where there is electrical wiring in the way.
Select another location or have a qualified electrician move
the wiring to a different location.
DANGER: Before servicing or cleaning unit, switch power off
at the service panel and lock service panel to prevent power
from being switched on accidentally. When the service dis-
connecting means cannot be locked, securely fasten a
prominent warning device, such as a tag to the service
panel.
LACERATION HAZARDS
DANGER: This fan has an unguarded fan blade. Do not use
in locations which are readily accessible to people or ani-
mals. Do not let children play in an attic where this fan has
been installed. Contact with this fan while in operation can
result in injury or even death.
DANGER: Switch the power of
f at the service panel and lock
the service panel before servicing the motor. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag to the service
panel. This fan is thermostatically controlled - it may start at
any time if the power is not switched off at the service panel.
Contact with the fan blades while the fan is operating can
result in serious injury
.
WARNING: This product has sharp metal edges that can cut
your hands. W
ear canvas work gloves while handling the fan
during installation.
OTHER HAZARDS
DANGER:
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
Use of this fan to exhaust hazardous, explosive or flammable
materials may result in a fire or explosion, causing injury or
death.
PRECAUCIÓN: Lea todos las instrucciónes y advertencias,
antes de empezar a instalar este ventilador. El caso omiso
de estas instrucciónes, puede ocasiónarle lesiónes graves o
inclusive hasta la muerte. Si usted necesita ayuda para com-
prender estas instrucciónes, tiene preguntas o comentarios,
favor de llamar al: 1 (309) 692-6969.
RIESGOS ELECTRICOS
PELIGRO
:
La instalación electrica y el alambrado de este
ventilador debera ser hecho por una electricista cualificado
de acuerdo con todos códigos y las normas locales,
incluyendo normas de fuego para la construcción. El caso
omiso de una instalación apropiada puede provocar fuego o
inclusive hasta la muerte. NOTA: Unas pocas horas con el
ventilador operando sin problemas aparentes no significa
que la instalación sea segura.
PELIGRO: No substituya el control termostático de interrup-
tor que controla el encendido y apagado que viene con este
ventilador. Usar de cualquier otro control puede provocar
fuego causando heridas o hasta la muerte.
PELIGRO: Tenga cuidado con las instalaciónes electricas
ya existentes o cualquier otra instalación o tuberías cuando
elija el lugar apropiado para su ventilador. No instale el ven-
tilador donde haya alambres o cables que le puedan estor-
bar. Elija otro lugar o consulte con un electricista cualificado
para hacer un movimiento de instalación electrica adecuada
hacia otro lugar.
PELIGRO: Antes de hacer servicio o limpieza a la unidad,
cerciórese de cortar la corriente de la caja de registro eléc-
trico y asegúrela para prevenir que se haga una conexión
imprevista. Si es imposible asegurar la caja de registro eléc-
trico, amarre seguramente un aviso del peligro tal como una
etiqueta a la caja.
RIESGOS DE LACERACIÓN
PELIGRO:
Este ventilador tiene unas aspas peligrosas de
metal sin protección. No coloque en lugares al alcance de
las personas o animales. No permita que los niños jueguen
en el ático cuando el ventilador haya sido instalado. El con
-
tacto con este ventilador cuando esté en funcionamiento
puede provocar daños graves o inclusive hasta la muerte.
PELIGRO: Ceriórese de cortar la corriente de la caja de
registro eléctrico y asegúrela, antes de empezar a trabajar
en la banda del motor o el motor
. El contacto con la banda
del ventilador mientras esté funcionando puede ocasionarle
heridas graves. Esto también le puede atraer hacia las
aspas provocando daños más graves o inclusive hasta la
muerte.
PRECAUCIÓN: Este producto tiene bordes muy afilados
que podrían cortarle las manos. Use guantes de lona mien-
tras usted esté instalado el ventilador
.
OTROS RIESGOS
PELIGRO: Uso exclusivo para ventilación general. No use
este producto para extraer gases peligrosos, materiales
explosivos u otros vapores.
Installation Instructions
Roof Mounted Power Attic Ventilator
V
entilador de Poder Del Ático Montado en el Techo
Important Safety Information
Información Importante Para Su Seguridad
Part No. 18370
ROOF MOUNTED POWER ATTIC VENTILATOR
INST
ALLATION INSTRUCTIONS
NOTE: Air intake openings are necessary for proper
exhaust operation. Best results will be obtained if these
openings are located around the eaves. Undereave soffit
grills or continuous soffit vents are suggested.
Sq. Ft. of
Air Intake
Model Opening Needed
RV26 3.9
RV28 4.4
TOOLS NEEDED: Electric drill, tape measure, hammer &
nails, utility knife and pencil, jig or sabre saw, roofing
nails, phillips screw driver, adjustable wrench, wire cutter,
work gloves and safety glasses.
VENTILADOR DE PODER DEL ÁTICO
MONTADO EN EL TECHO
INSTRUCCIÓNES PARA LA INSTALACIÓN
NOTA: Aberturas para la toma de aire son necesarias
para una apropiada operación. Se obtendrán mejores
resultados si estas aberturas están localizadas alrededor
de los aleros. Se sugiere el uso de rejiillas de sofito bajo
alero o ventilas continuas de sofito.
Pies cuadrados (metros cuadrados) de abertura
Modelo para toma de aire abertura necesaria.
RV26 3.9
RV28 4.4
HERRAMIENTAS REQUERIDAS PARA INSTALACION:
Taladro, cinta de medir o regla, martillo, clavos para
techo, navaja, lapiz, serrucho, destornillador llave, tijeras,
lentes de seguridad y guantes de uso rudo.
1. POSITIONING THE POWER ATTIC VENTILATOR ON
THE ROOF: Set the unit approximately in the center of
the roof close to the ridgeline. Position the ventilator so
that the unit can only be seen from one side of the house.
1. ACOMODANDO EL VENTILADOR DE PODER EN EL
TECHO: Acomode la unidad aproximadamente en el cen-
tro del techo cerca del madero horizontal superior.
Acomode la unidad de tal manera que solo se pueda ver
de un lado de la casa.
2. DRILL THE GUIDE HOLE: Measure the distance to
the ridgeline and to one end of the roof. Transfer these
exterior dimensions to inside the attic. Next locate a cen-
ter position between two rafters (inside the attic) as near
as possible to the outside measurements. Drill a guide
hole through the roof from inside that is equal distance
from the two rafters. Place a marker through the roof for
quick identification while on the roof.
2. HAGA EL AGUJERO-GUÍA: Mida la distancia del
madero horizontal superior hasta el punto final del techo.
T
raslade las medidas exteriores a la parte interna del
ático. Despues localice una posición centrada entre 2
vigas (dentro del ático) lo mas cerca posible de las
dimensiónes exteriores. Haga un agujero guía en el
techo. Ponga una marca en el techo para una identifi-
cación más rapida mientras esté en el techo.
3. CUTTING THE HOLE: Draw a circle 14
1
/2´´ in diame-
ter using the guidehole as the center. A template is pro-
vided on the back of the carton for drawing the circle.
3. PARA HACER EL AGUJERO: Dibuje un círculo de 14
1/2 pulgadas de di·metro usando el agujero-guía como el
centro. El patrón viene incluido en la parte trasera de la
caja de carton, para dibujar el círculo.
4.
CUTTING
THE HOLE IN THE ROOF. Using a sabre
saw
, cut and remove all roof shingles (and deck) inside
the 14 1/2´´ diameter circle. Next cut an extra 1 inch off
the top half of the hole (shingles only) to allow room for
placing and positioning the flange.
Do not cut through any rafters. Cutting a rafter may cause
your roof to sag.
1.)
2.)
3.)
4. PARA CORTAR EL AGUJERO EN EL TECHO:
Usando una sierra caladora, corte y remueva las tejas (y
la madera) que este adentro del círculo de 14 1/2 pul-
gadas de diámetro. Después corte 1 pulgada más en la
parte de arriba del agujero (solo la teja) para dar espacio
y acomodar la corona.
No corte ningúna viga. El cortar una viga puede causar
que su techo se hunda.
5. SECURING THE BASE: Make sure the base flange
parallels the ridgeline of the roof. The embossed arrow
and word UP should be pointing towards the ridgeline.
Slip the upper half of the flange under the shingles.
Center unit over the hole. Attach flange securely to roof
using roofing nails around the perimeter of the unit
(Underneath shingles at the top). A nonhardening caulk
can be used to seal between the flange and shingles.
5. PARA ASEGURAR LA BASE: Cerciórese de que la
base de la corona esté paralela con la del madero hori-
zontal superior del techo. Las flechas realizadas y la pal-
abra “UP” deben estar apuntado hacia el madero hori-
zontal superior. Deslice la parte superior de la corona
debajo de las tejas.
Centre la unidad sobre el agujero. Junte la corona
seguramente al techo usando clavos para techo alrede-
dor del perímetro de la unidad (debajo de las tejas supe-
riores). Una goma suave puede ser usada para sellar la
corona con la teja.
6. INSTALLING THE THERMOSTAT: Inside the attic,
separate the thermostat cover from the mounting plate.
Secure the plate to a rafter. See step 7 to connect the
thermostat.
6. PARA INSTALAR EL TERMOSTATO: Dentro del ático,
separe la cubierta del termostato de la base de montaje.
Asegure la base a una viga. V
ea el paso 7 para conectar
el termostato.
7. WIRING THE THERMOSTAT:
DANGER: The electrical installation and wiring of this fan
must be done by a qualified electrician in accordance with
all local codes and standards, including fire-rated con-
struction. Failure to do the installation properly can result
in fire or even death. NOTE: A few hours of operation
without apparent problems does not necessarily imply
that the installation is safe.
DANGER: Do not substitute a solid state speed control
for the thermostatically controlled on-off switch that
comes with this fan. Use of a solid state speed control
can result in a fire causing injury or death.
DANGER: Make sure the circuit breaker powering the cir-
cuit on which the fan will operate is turned OFF before
wiring the thermostat. You can be shocked or electrocuted
if the breaker is not off.
W
ire the thermostat as shown in diagram 7.
Attach your
ground wire to the thermostat box.
7.
ALAMBRANDO DEL
TERMOST
A
T
O:
PELIGRO: La instalación eléctrica y el alambrado de
este ventilador deberá ser hecho por una electricista
capacitado de acuerdo con todos códigos y normas
locales, incluyendo normas contra incendios en la con-
strucción. El caso omiso de una instalación apropiada
puede provocar incendios o inclusive la muerte. NOTA:
Unas pocas horas con el ventilador operando sin proble-
mas aparentes no significa que la instalación sea segura.
PELIGRO: No substituya con un control de velocidades
transistorizado el control termostático del interruptor que
controla el encendido y apagado que viene con este ven-
tilador. El uso de cualquier otro control puede provocar
incendios, causando heridas o aún la muerte.
P
ELIGRO:
Cerciórese de que el circuito de poder que va
alimentar el circuito del ventilador este
APAGADO antes
5.)
6.)
4.)
de conectar el termostato. Podría usted recibir una
descarga eléctrica o resultar electrocutado si la corriente
no está apagada.
Conecte el termostato como muestra en el diagrama 7.
Conecte el alambre de tierra a la caja del termostato.
8. THERMOSTAT OPERATION: The thermostat oper-
ates on a temperature setting. Set the temperature dial
to a 100-110°F setting. When the power ventilator is oper-
ational, the fan should start automatically when the attic
temperature rises above the preset setting and cut off
when the attic is cooled down to the thermostat setting.
DANGER: Switch the power off at the service panel and
lock the service panel before servicing the motor. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag
to the service panel. This fan is thermostatically controlled
- it may start at any time if the power is not switched off at
the service panel. Contact with the fan blades while the
fan is operating can result in serious injury.
8. OPERACIÓN DEL TERMOSTATO: El termostato fun-
ciona según la temperatura indicada. Ajuste el marcador
a una posición de 100 - 110° F. Cuando el ventilador de
poder esté listo para operar, empezará a trabajar
automáticamente cuando la temperatura del desván suba
de la posición marcada y se apagara cuando la temper-
atura en el desván sea menos que la posición indicada
en al termostato.
PELIGRO: Cerciórese de cortar la corriente de la caja de
registro eléctrico y asegúrela, antes de empezar a traba
-
jar en el motor. Si es imposible asegurar la caja de reg-
istro eléctrico, amarre seguramente un aviso del peligro
tal como una etiqueta a la caja. Este ventilador está con
-
trolado por un termostato que lo puede hacer funcionar
en cualquier momento si el interruptor no está apagado
en la caja de registro eléctrico. El contacto con las aspas
de este ventilador cuando el ventilador esté operando
puede provocar daños serios.
LIMITED WARRANTY
Model R
V28 is warranted for ten years and Model R
V26 is war-
ranted for five years from date of purchase against defects in
workmanship and materials.
This warranty covers fan blade,
motor, thermostat and housing. If you believe any part is defective,
call 1-800-527-1924 for Customer Service. If it’s determined that
parts need to be returned, they must be shipped freight prepaid to
Air Vent, 4117 Pinnacle Point Drive, Suite 400, Dallas, TX 75211. If
found to be defective following examination by
Air V
ent, any defec
-
tive part will be replaced free of charge and returned freight pre-
paid. This warranty does not cover any labor costs, including those
required for field repair or replacement or removal of any allegedly
defective part. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.
REPLACEMENT PLUS PROTECTION
The Air Vent product to which this warranty applies is covered
by Replacement Plus protection for a period of five (5) years
(Model RV28) or two (2) years (Model RV26), provided that the
product has been installed in strict accordance with Air Vent’s
written installation instructions and in accordance with all local
codes and standards, including those pertaining to fire-rated con-
struction. Under this warranty feature, Air Vent, at no charge, will
replace any part covered by this warranty and found to be defec-
tive during the Replacement Plus period (the Replacement Plus
period begins when the power vent installation is completed.)
Air
Vent’s maximum liability under Replacement Plus will be equal to
the reasonable cost of the replacement part, including labor to
remove the defective part and install the replacement part.
In instances in which Air Vent, according to the terms of this
warranty, has agreed to pay the cost of labor required to replace
a defective part, Air Vent will provide reimbursement only upon
receipt of a copy of the contractor’s invoice or other written evi-
dence of the completion of the work which Air Vent, at its sole
discretion, deems acceptable.
LÍMITE GARANTÍA
Modelo RV28 está garantizado por 10 años y Modelo RV26
está garantizado por 5 años desde la fecha de su compra, contra
defectos de manufactura y materiales. Esta garantía cubre las
aspas, el motor, el termostato, y la cubierta de metal. Si usted
considera que alguna pieza es defectuosa, llame al
Departamento de Servicio al Cliente, 1-800-527-1924. Si se
determina que las piezas deben ser devueltas a Air Vent, envíe-
las con porte postal prepagado a Air Vent, 4117 Pinnacle Point
Drive, Suite 400, Dallas, TX 75211. Si encontramos defectos
bajo el examen de Air Vent, Inc., cualquier parte será reem-
plazada sin costo alguno y le devolveremos el dinero de su
flete. Esta garantía no cubre ningún costo por mano de obra,
incluyendo aquellos solicitados para reparar fallas, reemplaza-
mientos o cambio de cualquier parte defectuosa que se declare.
Esta garantía le da derechos específicos y legales, y usted
asimismo tendrá otros derechos los cuales varían de estado a
estado.
PROTECCIÓN REPLACEMENT PLUS
El producto de ventilación Air Vent para el cual esta garantía apli-
ca está cubierto con la protección Replacement Plus por un peri-
odo de 5 annos (Modelo RV28) o 2 annos (Modelo RV26), a
condición de que el producto haya sido instalado de acuerdo con
las instrucciones escritas de instalación de Air Vent y de acuerdo
con todos los estándares y códigos locales, incluyendo aquellos
pertinentes al factor de riesgo de incendio en las construcciones.
Bajo este aspecto de la garantia, Air Vent, sin costo alguno, rem-
plazará cualquier pieza cubierta por la garantia encontrada defec-
tuosa durante el periodo marcado por la proteccion Replacement
Plus (el periodo Replacement Plus inicia cuando la instalación
eléctrica del ventilador sea concluida). La responsabilidad máxi
-
ma de Air Vent, bajo el periodo de Replacement Plus será igual al
costo de la parte a reemplazar, incluyendo la mano de obra
requerida para remover la parte defectuosa e instalar la parte de
reemplazo.
En circustancias en las cuales Air Vent, de acuerdo con los tér-
minos de esta garantia, haya acordado pagar el costo de la
mano de obra para reemplazar una parte defectuosa,
Air V
ent
proveerá el reembolso solamente bajo la recepción de una
copia de la factura del contratista u otra evidencia escrita de la
conclusión del trabajo, la cual será juzgada aceptable bajo la
exclusiva discreción de Air Vent.
Air Vent Inc.
4117 Pinnacle Point Drive
Suite 400
Dallas,
T
exas 7521
1
7.)
WIRING THE THERMOSTAT
CONECTANDO EL TERMOSTATO
Part No. 18370
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Air Vent RV26GR Instrucciones de operación

Tipo
Instrucciones de operación
Este manual también es adecuado para

En otros idiomas