DeWalt DW0350 Manual de usuario

Tipo
Manual de usuario
Please read these instructions before operating the product.
www.DEWALT.com
DW0350
Stud Sensor
E
PT
ES
F
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 1 5/21/2019 3:39:22 PM
A
1
3
2
4
5
6
7
< 25%
25%
50%
75%
100%
< 25%
Figures
2
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 2 5/21/2019 3:39:24 PM
C
B
1
2
3
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 3 5/21/2019 3:39:25 PM
D
Figures
4
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 4 5/21/2019 3:39:28 PM
E
1
2
5
6” - 18”
12”
AC
AC
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 5 5/21/2019 3:39:29 PM
F
Figures
6
~
~
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 6 5/21/2019 3:39:34 PM
7
E
Contents
• Stud Sensor Information
• User Safety
• Battery Safety
• Installing AAA Batteries
• Using the Stud Sensor
• Maintenance
• Troubleshooting
• Service and Repairs
• Warranty
• Specications
Stud Sensor Information
The Stud Sensor DW0350 uses electronic signals to locate the center of
wood or metal studs, live AC wires, or metal objects (e.g., pipe) through
drywall or other common building materials.
PLEASE NOTE:
The stud sensor will not detect objects in concrete, mortar, block, brick
work, plaster, carpeting, foil-faced materials, metallic surfaces, or ceramic
tile.
The stud sensor will not detect plastic or PVC pipes.
Once the center of a wood or metal stud, or a metal object has been
detected in one pass across the surface, the Stud Sensor DW0350 turns on
the center LEDs and sounds an audible tone. A marking hole allows you to
easily note the current position on the wall.
User Safety
Safety Guidelines
The denitions below describe the level of severity for each signal word.
Please read the manual and pay attention to these symbols.
WARNING: Indicates a potentially hazardous situation which, if not
avoided, could result in serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury which, if not
avoided, may result in property damage.
If you have any questions or comments about this or any D
EWALT
®
tool, go to www.DEWALT.com.
WARNING:
Read and understand all instructions. Failure to follow the
warnings and instructions in this manual may result in serious
personal injury.
SAVE THESE INSTRUCTIONS
WARNING:
The following label information can be found on your tool for your
safety.
WARNING:
If the equipment is used in a manner not specied by the
manufacturer, the protection provided by the equipment may
be impaired.
CAUTION:
Protect your eyes. Wear safety goggles.
WARNING:
This tool is not a measuring device and should not be used as
a substitute for a voltmeter.
WARNING:
The LED or Live Wire Detection symbol on the display is just an
indicator and in some situations the voltage detection option may
not accurately indicate the presence of voltage in a wall in the
event of internal device failure or improper operation, and therefore
should not be solely relied upon for identication of the presence
of hazardous voltages. Other evidence, such as construction
blueprints or visual identication of wiring or conduit entry points
should also be utilized.
Always follow proper safety practices and use a separate detection
method to verify a de-energized condition prior to commencing
work.
WARNING:
Always turn off AC power when working near wiring.
WARNING:
Shielded wires or wires in metal conduits, casings, metalized
walls, or thick, dense walls may not be detected.
CAUTION:
Use personal protective equipment. Always wear eye protection.
Depending on the work conditions, wearing protective equipment
such as a dust mask, non-skid safety shoes, hard hat, and hearing
protection will reduce the risk of personal injury.
IMPORTANT SAFETY NOTICE
Ensure proper detection of live wires. Always hold the Stud Sensor
DW0350 in the handle area only. Grasp between ngers and thumb while
making contact with your palm (Figure
C
1
).
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 7 5/21/2019 3:39:34 PM
8
E
Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identier: DW0350
Responsible Party – U.S. Contact Information
DEWALT
701 East Joppa Road
Towson, Maryland 21286
www.DEWALT.com
FCC Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a different circuit (not the circuit to
which the receiver is connected).
- Consult the dealer or an experienced radio/TV technician for help.
Canada, Industry Canada (IC) Notices
This Device complies with Industry Canada License-exempt RSS
standard(s). Operation is subject to the following two conditions: 1) this
device may not cause interference, and 2) this device must accept any
interference, including interference that may cause undesired operation of
the device.
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for
the transmitter by Industry Canada. To reduce potential radio interference
to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Battery Safety
WARNING:
Batteries can explode, or leak, and can cause injury or re. To
reduce this risk:
Carefully follow all instructions and warnings on the battery label and
package.
Always insert batteries correctly with regard to polarity (+ and –), as
marked on the battery and the equipment.
Do not short battery terminals.
Do not charge disposable batteries.
Do not mix old and new batteries. Replace all batteries at the same time
with new batteries of the same brand and type.
Remove dead batteries immediately and dispose of per local codes.
Do not dispose of batteries in re.
Keep batteries out of reach of children.
Installing AAA Batteries
Load two new AAA batteries in the DW0350 stud sensor.
1.
On the bottom of the stud sensor, lift up the latch (Figure
B
1
) to
unlock the battery compartment cover.
2.
Move the cover upward (Figure
B
2
) and remove it once it separates
from the stud sensor.
3.
Insert two new, high-quality AAA batteries, making sure to position the
- and + ends of each battery as noted inside the battery compartment
(Figure
B
3
).
4.
Place the cover back on the stud sensor (Figure
B
4
).
• Insert the two pins at the top of the cover into the holes near the top of
the battery compartment.
• Slowly lower the cover and press down until the latch locks securely
on the stud sensor.
5.
Press or to test the stud sensor.
• The stud sensor should sound one short beep. The Power
LED
and the battery icon on the LCD screen should turn on.The AC LED
and all the other icons on the LCD screen should illuminate for a
second and then turn off.
• Whenever you press
or , the green Power LED should
illuminate to indicate that the batteries are good. If this LED blinks
or does not illuminate, change the batteries. When or is
pressed, the battery level appears on the LCD screen (Figure
A
7
).
Using the Stud Sensor
The DW0350 stud sensor will help you nd wood or metal studs, AC
voltage, or metal objects (e.g., pipe) behind drywall.
The stud sensor has two buttons. Use the bottom button (Figure
A
3
) to
search for wood/metal studs or AC, and use the top button (Figure
A
2
)
to search for metal objects (e.g., pipe).
The stud sensor will detect wood studs through up to 1” (25mm) thick
drywall, and metal studs and AC voltage through up to 1.5” (38mm) thick
drywall.
The stud sensor will detect a ferrous metal object (contains iron) up to 3”
(76.2mm) from the surface of the wall to the center of the object.
The stud sensor will detect a non-ferrous metal object (e.g., copper) up to
2” (51mm) from the surface of the wall to the center of the object.
When AC voltage is found, the stud sensor will sound short (alternating)
beeps, light the AC LED (Figure
A
5
), and display the AC icon on the
LCD screen (Figure
A
4
).
When the center of a stud is found (or a metal object is nearby), the stud
sensor will sound one longer (constant) beep and display the center
arrows
on the LCD screen (Figure
A
4
).
When live AC and the center of a stud are both found, the stud sensor will
alternate between the long and short beeps, display
and on the
LCD screen, and illuminate the AC LED.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 8 5/21/2019 3:39:36 PM
9
E
Finding a Stud
1.
To hold the stud sensor, place your thumb on one side of the stud
sensor, your pointer finger and your palm over the center of the stud
sensor, and the rest of your fingers on the same hand on the other side
of the stud sensor (Figure
C
1
).
2.
Gently place the stud sensor flat against the wall and parallel to a door
or window on the same wall, which gives you an indication of how the
studs are positioned behind the wall (Figure
C
2
).
3.
Without moving the stud sensor, use your pointer finger to press and
hold (Figure
A
3
). WAIT 1 sec until all the LEDs (except the
Power LED) turn off and all icons on the LCD screen turn off except
the battery level.
4.
While still pressing , SLOWLY move the stud sensor to the left or
the right on the wall.
5.
As you move the stud sensor, watch the stud sensor arrows displayed
on the LCD screen and listen for beeps.
• If
appears on the right side of the LCD screen (Figure
D
1
),
continue moving the stud sensor to the right to find the nearest stud.
As you get closer to the stud, will appear on the LCD screen
(Figure
D
2
).
• If
appears on the left side of the LCD screen, continue moving
the stud sensor to the left to find the nearest stud. As you get closer to
the stud, will appear on the LCD screen.
• If live AC voltage is found within 6”-18” (.15m - .5m) of the stud
sensor’s current position, the AC LED will illuminate,
will appear on
the LCD screen, and you will hear short beeps.
NOTE: Static electrical charges that can develop on drywall and
other surfaces will spread the voltage detection area many inches on
each side of the actual electrical wire. This can cause the stud sensor
to indicate that it has found live AC when it is not actually near an
electrical wire (Figure
E
1
). To aid in locating the wire position, place
your other hand on the surface approximately 12” (30cm) from the
stud sensor (Figure
E
2
), or hold the stud sensor ½” - 2” (13mm -
50mm) away from the wall surface.
6.
When the center arrows appear on the LCD screen and you hear
a constant beep, the stud sensor has found the center of a stud (Figure
D
3
).
NOTE: If live AC voltage is found near the center of a stud, the AC LED
will illuminate, both
and will appear on the LCD screen, and the
stud sensor will sound short alternating beeps (AC found) followed by a
longer constant beep (stud center found).
• STOP moving the stud sensor and continue to hold it at the current
position.
• STOP pressing
.
7.
Through the hole on the stud sensor (Figure
D
4
) use a pencil to
mark the current position on the wall as the center of the stud.
8.
To find another stud on the wall, repeat the same steps.
Finding Metal Objects
The stud sensor will let you know if a metal object (e.g., a pipe) is located
behind the wall within 3” (76.2mm) of the stud sensor. In metal detection
mode, the arrows do not indicate which direction to move the stud
sensor to nd metal.
1.
To hold the stud sensor, place your thumb on one side of the stud
sensor, your pointer finger and your palm over the center of the stud
sensor, and the rest of your fingers on the same hand on the other side
of the stud sensor (Figure
C
1
).
2.
Position the stud sensor flat against the wall and parallel to a door or
window on the same wall, which gives you an indication of how the
studs are positioned behind the wall (Figure
C
2
).
3.
Without moving the stud sensor, use your pointer finger to press and
hold
(Figure
A
2
). WAIT 1 sec until all the LEDs (except the
Power LED) turn off and all icons on the LCD screen turn off except
the battery level and .
4.
While still pressing , SLOWLY move the stud sensor to the left or
the right on the wall.
5.
As you move the stud sensor, watch the arrows displayed on the LCD
screen.
• When
and appear on the LCD screen, slowly move the
stud sensor to the left or right to find the metal object (Figure
F
1
).
• When
and appear on the LCD screen, you will know that
you are moving the stud sensor closer to the metal object (Figure
F
2
).
6.
When the center arrows appear on the LCD screen (Figure
A
4
) and
you hear a constant beep, the stud sensor has found a metal object
within 3” (76.2mm) to the left or right of the current position (Figure
F
3
).
• STOP moving the stud sensor and continue to hold it at the current
position.
• STOP pressing
.
7.
Through the hole on the stud sensor (Figure
F
4
) use a pencil to
mark the current position on the wall.
• The metal object may be within 3” (76.2mm) to the left or right of the
mark.
• For the exact position of the metal object, you should refer to building
drawings.
8.
To find another metal object behind the wall, repeat the same steps.
Maintenance
When the stud sensor is not in use, clean the exterior parts with a damp
cloth, wipe the stud sensor with a soft dry cloth to make sure it is dry.
Although the stud sensor exterior is solvent resistant, NEVER use
solvents to clean the stud sensor.
Store the stud sensor in a clean location at a temperature between -67 ˚F
(-55 ˚C) and 158 ˚F (70 ˚C).
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 9 5/21/2019 3:39:38 PM
10
E
Troubleshooting
The LED is Blinking
If the power LED blinks (and the battery level on the LCD screen blinks),
the battery power is low.
Check the AAA batteries to make sure:
• Each battery is installed correctly, according to + and listed inside
the battery compartment.
• The battery contacts are clean and free of rust or corrosion.
• The batteries are new, high-quality batteries to reduce the chance of
battery leakage.
Make sure the AAA batteries are in proper working condition. If in doubt,
try installing new batteries.
The LED does not Turn On
If the power LED does not turn on, or the power LED turns on for 1
sec and then turns off, there is no battery power.
Install two new, high-quality, name-brand AAA batteries in the stud sensor.
Make sure each battery is installed correctly, according to + and listed
inside the battery compartment.
The Stud Sensor is not Finding Studs
Make sure the batteries are working.
Make sure you have placed the stud sensor on a wall made of drywall or
another common building material. The stud sensor will not work on walls
made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced
materials, metallic surfaces, or ceramic tile.
Make sure you have placed the stud sensor at against the wall, the stud
sensor is in a vertical position (parallel to a door or window), and you are
pressing and holding
(Figure
A
3
) as you move the stud sensor
SLOWLY against the wall.
Make sure the wall is not too thick. The DW0350 stud sensor can be used
to detect wood studs on walls < 1” (25mm) thick or metal studs on walls <
1.5” (38mm) thick.
Make sure the wall has a smooth surface.
Make sure the temperature is within the specied Operating Range and
Relative Humidity.
The Stud Sensor is not Finding Metal Objects
Make sure the batteries are working.
Make sure you have placed the stud sensor on a wall made of drywall or
another common building material. The stud sensor will not work on walls
made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced
materials, metallic surfaces, or ceramic tile.
Make sure you have placed the stud sensor at against the wall, the stud
sensor is in a vertical position (parallel to a door or window), and you are
pressing and holding
(Figure
A
2
) as you move the stud sensor
SLOWLY against the wall.
Make sure the wall is not too thick. The DW0300 stud sensor can be used
to detect Non-Ferrous Metal (e.g., copper) on walls < 2” (51mm) thick or
Ferrous Metal (contains iron) on walls < 3” (76.2mm) thick.
Make sure the wall has a smooth surface.
Make sure the temperature is within the specied Operating Range and
Relative Humidity.
Service and Repairs
Note: Disassembling the tool will void all warranties on the product.
To assure product SAFETY and RELIABILITY, repairs, maintenance and
adjustment should be performed by authorized service centers. Service
or maintenance performed by unqualied personnel may result in a risk of
injury. To locate your nearest D
EWALT service center, go to www.DEWALT.
com.
Warranty
Go to www.DEWALT.com for the latest warranty information.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 10 5/21/2019 3:39:39 PM
11
E
Specications
DW0350
Detect Wood Studs up to 1” (25mm) thick drywall
Detect Metal Studs up to 1.5” (38mm) thick drywall
Detect Live AC Wire
110V @ 60 Hz (220V @ 50Hz)
up to 2” (51mm) behind the surface of the wall
from a distance of 6”-18” (.15 m- .5 m) AC LED will illuminate
Detect Ferrous Metal (contains iron) up to 3” (76.2mm) from the surface of the wall
to the center of the metal object (pipe)
Detect Non-Ferrous Metal (e.g., copper) up to 2” (51mm) from the surface of the wall
to the center of the metal object (pipe)
Accuracy - Center of Wood stud +/- 1/4” (6.4mm) under 1/2” to 1” (12.7mm - 25mm) thick drywall
Accuracy - Center of Metal stud +/- 1/4” (6.4mm) under 1/2” to 1.5” (12.7mm - 38mm) thick drywall
Accuracy - Detecting Metal Objects +/- 3” (76.2mm)
Power Source 2 AAA (1.5V) size batteries (3V DC)
Battery Life
< 10 hrs of continual use at <2.4V (+/- 0.3V),
Power LED will ash to indicate low battery
Automatic Calibration Yes
Automatic Shutoff when release button Yes
Non-marring Surface Yes
Relative Humidity 35% - 55%
Operating Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 150°F (-20°C to 66°C)
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 11 5/21/2019 3:39:39 PM
12
ES
Contenido
• Información de Sensor de Postes
• Seguridad de usuario
• Seguridad de batería
• Instalación de Baterías AAA
• Uso del Sensor de Postes
• Mantenimiento
• Solución de problemas
• Servicio y Reparaciones
• Garantía
• Especicaciones
Información de Sensor de Postes
El sensor de postes DW0350 utiliza señales electrónicas para ubicar el
centro de los postes de madera o metal, los cables de CA activos, o objetos
metálicos (p. ej., tubería) a través de paneles de yeso u otros materiales de
construcción comunes.
TENGA EN CUENTA:
El sensor de postes no detectará objetos en concreto, mortero, bloques,
ladrillos, yeso, alfombras, materiales con revestimiento metálico,
supercies metálicas o baldosas de cerámica.
El sensor de perno no detectará tubos de plástico o PVC.
Una vez que el centro de un perno de madera o metal, o un objeto metálico
se ha detectado en un paso a través de la supercie, el sensor de postes
DW0350 enciende los LEDs centrales y suena un tono audible. Un oricio
de marcado le permite indicar fácilmente el centro del poste.
Seguridad del usuario
Guías de Seguridad
Las siguientes deniciones describen el nivel de severidad para cada
palabra de señal. Por favor lea el manual y ponga atención a estos
símbolos.
ADVERTENCIA: Indica una situación potencialmente peligrosa
que, si no se evita, podría resultar en lesiones serias.
PRECAUCIÓN: Indica una situación potencialmente peligrosa que,
si no se evita, puede resultar en lesiones menores o moderadas.
AVISO: Indica una práctica no relacionada con lesiones personales que,
si no se evita, puede resultar en daño a la propiedad.
Si tiene cualquier pregunta o comentario sobre esta o cualquier
herramienta D
EWALT
®
, visite
www.DEWALT.com.
ADVERTENCIA:
Lea y entienda todas las instrucciones. La falla en seguir las
advertencias e instrucciones en este manual puede resultar en
lesiones personales serias.
CONSERVE ESTAS INSTRUCCIONES
ADVERTENCIA:
La información de la etiqueta siguiente se puede encontrar en su
herramienta para su seguridad.
ADVERTENCIA:
Si el equipo se utiliza de una manera no especicada por el
fabricante, la protección proporcionada por el equipo puede ser
deteriorada.
PRECAUCIÓN:
Proteja sus ojos. Use gafas de seguridad.
ADVERTENCIA:
Esta herramienta no es un dispositivo de medición y no debe
usarse como sustituto de un voltímetro.
ADVERTENCIA:
El LED o el símbolo Live Wire Detection en la pantalla es sólo
un indicador y en algunas situaciones la opción de detección de
voltaje puede no indicar con precisión la presencia de voltaje en
una pared en caso de falla interna del dispositivo o funcionamiento
incorrecto, y por lo tanto no se debe conar únicamente para la
identicación de la presencia de voltajes peligrosos. También
se debe utilizar otra evidencia, como planos de construcción
o identicación visual del cableado o puntos de entrada al
conducto.
Siempre siga las prácticas de seguridad adecuadas y use un
método de detección separado para vericar una condición de
desenergización antes de comenzar a trabajar.
ADVERTENCIA:
Siempre apague la energía CA cuando trabaje cerca del cableado.
ADVERTENCIA:
Es posible que no se detecten cables o cables blindados en los
conductos metálicos, carcazas, paredes metalizadas o paredes
gruesas y densas.
PRECAUCIÓN:
Use equipo de protección personal. Siempre use protección
para los ojos. Dependiendo de las condiciones de trabajo, usar
equipo de protección tal como una máscara de polvo, zapatos de
seguridad anti-deslizantes, casco, y protección auditiva reducirá el
riesgo de lesiones personales.
AVISO DE SEGURIDAD IMPORTANTE
Asegure la detección adecuada de cables activos. Siempre sostenga el
sensor de postes DW0350 únicamente en el área de la manija. Sujete entre
los dedos y el pulgar mientras hace contacto con la palma (Figura
C
1
).
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 12 5/21/2019 3:39:40 PM
13
ES
Declaración de conformidad del proveedor
47 CFR § 2,1077 información de cumplimiento
Identicador único: DW0350
Parte responsable – información de contacto de Estados Unidos
DEWALT
701 East Joppa Road
Towson, Maryland 21286
www.DEWALT.com
Declaración de FCC
Este equipo ha sido probado y cumple con los límites para dispositivos
digitales de clase B, de conformidad con la parte 15 de las normas FCC.
Estos límites han sido diseñados para proporcionar una protección
razonable contra las interferencias nocivas en instalaciones residenciales.
Este equipo genera, usa e irradia energía de radiofrecuencia y, si no
se instala y se usa de acuerdo con las instrucciones, puede causar
interferencia perjudicial para las radiocomunicaciones. No obstante, no
existe ninguna garantía de que no se producirá interferencia en una
instalación determinada. Si este equipo causa interferencias perjudiciales
para la recepción de radio o televisión, que puede determinarse al
encender y apagar el equipo, el usuario puede tratar de corregir la
interferencia tomando una o varias de las siguientes medidas:
- Reorientar o reubicar la antena receptora.
- Aumentar la distancia entre el equipo y el receptor.
- Conectar el equipo en un tomacoriente de otro circuito diferente (no el
circuito al que está conectado el receptor).
- Consulte al vendedor o a un técnico experto en radio/TV para solicitar su
ayuda.
Seguridad de la Batería
ADVERTENCIA:
Las baterías pueden explotar, o tener fugas, y pueden causar
lesiones personales o incendios. Para reducir este riesgo:
Siga todas las instrucciones y advertencias colocadas en las etiquetas
y el paquete de las baterías.
Siempre inserte las baterías correctamente respecto a la polaridad
(+ y –), como está marcado en la batería y el equipo.
No ponga en corto las terminales de la batería.
No cargue las baterías desechables.
No mezcle baterías nuevas y viejas. Cambie todas las baterías al mismo
tiempo con baterías nuevas del mismo tipo y marca.
Retire las baterías descargadas de inmediato y deséchelas conforme
a los códigos locales.
No deseche las baterías en fuego.
Mantenga las baterías fuera del alcance de los niños.
Instalación de Baterías AAA
Cargue dos baterías AAA nuevas en el sensor de postes DW0350.
1.
En la parte inferior del detector de estructuras, levante el enganche
(Figura
B
1
) para abrir la tapa del compartimento de las pilas.
2.
Mueva la cubierta hacia arriba (Figura
B
2
) y retírela una vez que se
separe del sensor de postes.
3.
Inserte dos nuevas baterías AAA de alta calidad, asegurándose de
colocar los extremos - y + de cada batería como se indica en el interior
del compartimiento de baterías (Figura
B
3
).
4.
Coloque la cubierta de nuevo en el sensor de postes (Figura
B
4
).
• Inserte las dos clavijas en la parte superior de la cubierta en los
orificios cerca de la parte superior del compartimento de la batería.
• Baje lentamente la tapa y presione hacia abajo hasta que el seguro
se bloquee rmemente en el sensor de postes.
5.
Presione o para probar el sensor de postes.
• El sensor de postes emitirá un pitido corto. El LED de encendido y el
icono de la batería en la pantalla LCD debe encendearlo. El LED de
CA y todos los demás iconos de la pantalla LCD deben iluminarse por
un segundo y luego apagarlo.
• Siempre que presione
o , el LED de energía verde
se debe iluminar para indicar que las baterías están en buenas
condiciones. Si este LED parpadea o no se ilumina, cambie las
baterías. Cuando la herramienta esté ENCENDIDA, el nivel de
batería aparece en la pantalla (Figura
A
7
).
Uso del Sensor de Postes
El sensor de postes lo ayudará a encontrar postes de madera o metal,
voltaje CA, o objetos metálicos (p. ej., tubería) detrás de paneles de yeso.
El sensor de postes tiene dos botones. Utilice el botón inferior (Figura
A
3
) para buscar postes de madera/metal o AC, y utilice el botón superior
(Figura
A
2
) para buscar objetos metálicos (p. ej., tubería).
El sensor de postes detectará postes de madera a través de paneles de
yeso de hasta 1” (25mm) de grosor, y postes de metal y voltaje de CA a
través de hasta 1,5” (38mm) de espesor de yeso.
El sensor de postes detectará un objeto de metal ferroso (contiene hierro)
de hasta 3 “(76,2 mm) desde la supercie de la pared hasta el centro del
objeto.
El sensor de postes detectará un objeto metálico no ferroso (p. ej.,
cobre) hasta 2 “(51mm) desde la supercie de la pared hasta el centro
del objeto.
Cuando se encuentre voltaje CA, el sensor de postes emitirá un pitido
corto (alternando) y encenderá el LED de CA (Figura
A
5
) y mostrar el
icono de CA en la pantalla LCD (Figura
A
4
).
Cuando se encuentra el centro de postes (o un objeto metálico está
cerca), el sensor de postes proporciona un sonido más largo (constante)
y mostrar las flechas centrales
en la pantalla LCD (Figure
A
4
).
Cuando se encuentran tanto CA activo como el centro de un poste, el
sensor de postes se alternará entre los pitidos largos y cortos, mostrar
y en la pantalla LCD, y encenderá el LED de CA.
Encontrar un Poste
1.
Para sostener el sensor de postes, coloque el pulgar en un lado del
sensor de postes, el dedo índice y la palma sobre el centro del sensor
de postes, y el resto de los dedos en la misma mano en el otro lado del
sensor de postes (Figura
C
1
).
2.
Coloque suavemente el sensor de postes plano contra la pared
y paralelo a una puerta o ventana en la misma pared, lo que le dará
una indicación de cómo los postes están ubicados detrás de la pared
(Figura
C
2
).
3.
Sin mover el sensor de postes, use el dedo índice para mantener
presionado (Figura
A
3
). ESPERE 1 segundo hasta que todos
los LEDs (excepto el LED de encendido ) se apagarán y todos los
iconos de la pantalla LCD se apagan excepto el nivel de batería.
4.
Mientras sigue presionando , mueva LENTAMENTE el sensor de
postes hacia la izquierda o hacia la derecha en la pared.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 13 5/21/2019 3:39:41 PM
14
ES
5.
A medida que mueve el sensor de postes, observe las flechas
mostradas en la pantalla LCD y escuche los sonidos.
• Si las flechas lejanos
aparecen en lado derecho la pantalla
LCD (Figura
D
1
), continuar moviendo el sensor a la derecho para
encontrar el poste más cercano. A medida que te acerques el poste,
se aparece (Figura
D
2
).
• Si las flechas lejanos
aparecen en lado izquierdo la pantalla
LCD, continuar moviendo el sensor de postes a la izquierdo para
encontrar el poste más cercano. A medida que te acerques el poste,
se aparece.
• Si se encuentra CA activo dentro de 6”-18” (.15m - .5m) de la posición
actual del sensor de postes, el LED de CA (Figura
A
5
) se
iluminará, aparecen en la pantalla LCD y escuchará sonidos
cortos.
NOTA: Las cargas eléctricas estáticas que pueden desarrollarse
en los paneles de yeso y otras supercies extenderán el área de
detección de voltaje varias pulgadas a cada lado del cable eléctrico
real. Esto puede causar que el sensor de postes indique que ha
encontrado el AC vivo cuando no está realmente cerca de un cable
eléctrico (Figura
E
1
). Para ayudar a ubicar la posición del cable,
coloque la otra mano sobre la supercie a aproximadamente a 12”
(30cm) del sensor (Figura
E
2
) o escanee sosteniendo la unidad
a ½” - 2” (13mm - 50mm) de distancia de la supercie de la pared..
6.
Cuando las flechas central se aparezcan en la pantalla LCD
y escucha un sonido constante, el sensor de postes encontró el centro
de un poste (Figura
D
3
).
NOTA: Si se encuentra voltaje de CA activo cerca del centro de un
poste, el LED de CA se iluminarán,
y aparecen en la pantalla
LCD y el sensor de postes emitirá un sonido corto alterno (CA
encontrado) seguido de un sonido constante más largo (centro de perno
encontrado).
DEJE de mover el sensor de postes y continúe sujetándolo en la
posición actual.
• DEJE de presionar
.
7.
A través del orificio en el sensor de postes (Figura
D
4
), use un lápiz
para marcar la posición actual como el centro del poste.
8.
Para encontrar otro poste en la pared, repita los mismos pasos.
Encontrar de Objetos Metálicos
El sensor de postes le permitirá saber si un objeto metálico (p. ej., una
tubería) se encuentra detrás de la pared a menos de 3” (76.2mm) del
sensor de postes. En el modo de detección de metales, las echas no
indican en qué dirección mover el sensor de postes para encontrar
metal.
1.
Para sostener el sensor de postes, coloque el pulgar en un lado del
sensor de postes, el dedo índice y la palma sobre el centro del sensor
de postes, y el resto de los dedos en la misma mano en el otro lado del
sensor de postes (Figura
C
1
).
2.
Coloque suavemente el sensor de postes plano contra la pared
y paralelo a una puerta o ventana en la misma pared, lo que le dará
una indicación de cómo los postes están ubicados detrás de la pared
(Figura
C
2
).
3.
Sin mover el sensor de postes, use el dedo índice para mantener
presionado
(Figura
A
2
). Después de 1 segundo todos los LEDs
(excepto el LED de encendido ) se apagarán y todos los iconos de la
pantalla LCD se apagan excepto el nivel de batería y .
4.
Mientras sigue presionando , mueva LENTAMENTE el sensor de
postes hacia la izquierda o hacia la derecha en la pared.
5.
A medida que mueve el sensor de postes, observe las flechas
mostradas en la pantalla LCD.
• Cuando
y aparezca en la pantalla LCD, mueva
LENTAMENTE el sensor a la derecho o izquierda para encontrar el
objeto del metal (Figura
F
1
).
• Cuando
y aparezca en la pantalla LCD, usted sabrá
que está moviendo el sensor más cerca del objeto metálico (Figura
F
2
).
6.
Cuando las flechas central se aparezcan en la pantalla LCD
y escucha un sonido constante, el sensor encontró un objeto metálico
dentro de 3 “(76,2 mm) a la izquierda o a la derecha de la posición
actual (Figura
F
3
).
DEJE de mover el sensor de postes y continúe sujetándolo en la
posición actual.
• DEJE de presionar
.
7.
A través del orificio en el sensor de postes (Figura
F
4
), use un lápiz
para marcar la posición actual.
• El objeto metálico puede estar dentro de 3 “(76,2 mm) a la izquierda o
a la derecha de la marca.
• Para la posición exacta del objeto metálico, debe referirse a los
dibujos de construcción.
8.
Para encontrar otro objeto del metal, repita los mismos pasos.
Mantenimiento
Cuando el sensor de postes no esté en uso, limpie las partes exteriores
con un paño húmedo, limpie el sensor de postes con un paño suave
y seco para asegurarse que esté seco.
Aunque el exterior del sensor de postes es resistente a los solventes,
NUNCA use solventes para limpiar el sensor de postes.
Guarde el sensor de postes en un lugar limpio a una temperatura entre
-67 ˚F (-55 ˚C) y 158 ˚F (70 ˚C).
Solución de Problemas
El LED parpadea
Si el LED de energía verde parpadea (y parpadea el nivel de batería en
la pantalla LCD), la energía de la batería es baja.
Verique las baterías AAA para asegurarse que:
• Cada batería esté instalada correctamente, de acuerdo con + y -
enumerados dentro del compartimento de la batería.
• Los contactos de la batería están limpios y libres de óxido o corrosión.
• Las baterías son baterías nuevas de alta calidad para reducir la
posibilidad de fugas de la batería.
Asegúrese que las baterías AAA estén en buenas condiciones de
operación. En caso de duda, intente instalar baterías nuevas.
El LED no enciende
Si el LED no se enciende, o el LED se enciende durante 1 s y luego
se apaga, no hay energía de la batería.
Instale dos nuevas pilas AAA de alta calidad en el sensor de postes.
Asegúrese que cada batería esté instalada correctamente, de acuerdo
con + y - indicados dentro del compartimento de la batería.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 14 5/21/2019 3:39:42 PM
15
ES
El sensor de postes no encuentra postes
Asegúrese que las baterías estén en buenas condiciones.
Asegúrese de haber colocado el sensor de postes en una pared hecha
de paneles de yeso u otro material de construcción común. El sensor
de postes no funcionará en paredes hechas de concreto, mortero,
bloques, ladrillos, yeso, alfombras, materiales con revestimiento metálico,
supercies metálicas o baldosas de cerámica.
Asegúrese de haber colocado el sensor de postes plano contra la pared,
el sensor de espárrago está en una posición vertical (paralela a una
puerta o ventana), y está presionando y manteniendo presionado
(Figura
A
3
) mientras mueve el sensor de postes LENTAMENTE contra
la pared.
Asegúrese que la pared no sea demasiado gruesa. El sensor de postes
DW0350 se puede usar en paredes < 2” (51mm) de espesor. El sensor de
postes detectará postes de madera a través de paneles de yeso de hasta
1” (25mm) de grosor, y postes de metal a través de hasta 1,5” (38mm) de
espesor de yeso.
Asegúrese que la pared tenga una supercie lisa.
Asegúrese que la temperatura esté dentro del Rango de operación
y Humedad relativa especicados.
El sensor de postes no encuentra Objetos Metálicos
Asegúrese que las baterías estén en buenas condiciones.
Asegúrese de haber colocado el sensor de postes en una pared hecha
de paneles de yeso u otro material de construcción común. El sensor
de postes no funcionará en paredes hechas de concreto, mortero,
bloques, ladrillos, yeso, alfombras, materiales con revestimiento metálico,
supercies metálicas o baldosas de cerámica.
Asegúrese de haber colocado el sensor de postes plano contra la pared,
el sensor de espárrago está en una posición vertical (paralela a una
puerta o ventana), y está presionando y manteniendo presionado
(Figura
A
2
) mientras mueve el sensor de postes LENTAMENTE contra
la pared.
Asegúrese que la pared no sea demasiado gruesa. El sensor de postes
DW0300 detectará metales no ferrosos (p. ej., cobre) a través de hasta 2”
(51mm) y metales ferrosos (contiene hierro) hasta 3” (76.2mm) de grosor.
Asegúrese que la pared tenga una supercie lisa.
Asegúrese que la temperatura esté dentro del Rango de operación
y Humedad relativa especicados.
Servicio y Reparaciones
Nota: Desensamblar la herramienta anulará todas las garantías del
producto.
Para garantizar la SEGURIDAD y CONFIABILIDAD del producto, las
reparaciones, el mantenimiento y el ajuste deben ser realizados por centros
de servicio autorizados. El servicio o mantenimiento realizado por personal
no calicado puede ocasionar lesiones. Para localizar a su centro de
servicio D
EWALT más cercano, visite www.DEWALT.com.
Garantía
Vaya a www.DEWALT.com para obter informações sobre garantia.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 15 5/21/2019 3:39:42 PM
16
ES
Especicaciones
DW0350
Detectar postes de madera panel de yeso de hasta 1” (25mm)
Detectar postes de metal panel de yeso de hasta 1.5” (38mm)
Detectar cable de CA activo
110V @ 60 Hz (220V @ 50Hz)
hasta 2” (51mm) detrás de la supercie de la pared
desde una distancia de 6”-18” (0.15 m - 0.5 m) se iluminará el LED de CA
Detectar metales ferrosos (contiene hierro) hasta 3” (76.2mm) desde la supercie de la pared
hasta el centro del objeto metálico (tubería)
Detectar metales no ferrosos (p. ej., cobre) hasta 2” (51mm) desde la supercie de la pared
hasta el centro del objeto metálico (tubería)
Precisión - Centro de Poste de madera +/- 1/4” (6.4mm) bajo panel de yeso de 1/2” - 1”
(12.7mm - 25mm) de espesor
Precisión - Centro de Poste de metal +/- 1/4” (6.4mm) debajo de panel de yeso de 1/2” - 1.5”
(12.7mm - 38mm) de espesor
Precisión - Detectar objetos metálicos +/- 3” (76.2mm)
Fuente de energía 2 baterías tamaño AAA (1.5V) (3V CD)
Vida de batería
< 10 hrs de uso continuo en <2.4V (+/- 0.3V),
el LED de Energía parpadeará para indicar batería baja
Calibración automática
Apagado automático cuando se libera el botón de encendido
Supercie de protección
Humedad relativa 35% - 55%
Temperatura de operación 32°F a 122°F (0°C a 50°C)
Temperatura de almacenamiento -4°F a 150°F (-20°C a 66°C)
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 16 5/21/2019 3:39:42 PM
17
F
Table des matières
• Renseignements sur le détecteur de montants
• Sécurité de l'utilisateur
• Sécurité concernant les piles
• Installer des piles AAA
• Utiliser le détecteur de montants
• Entretien
• Dépannage
• Réparations
• Garantie
• Caractéristiques
Renseignements sur le Détecteur de
Montants
Le détecteur de montants DW0350 utilise des signaux électroniques pour
localiser le centre des montants en bois ou en métal, les ls sous tension,
ou des objets métalliques (p. ex. tuyau) à travers la cloison sèche.
VEUILLEZ NOTER :
Le détecteur de montants ne détectera pas les objets dans le béton, le
mortier, la roche, le briquetage, le plâtre, le tapis, les matériaux à base
de feuilles d’aluminium, les surfaces métalliques ou les carreaux de
céramique.
Le détecteur de montants ne détecte pas les tuyaux en plastique ou en
PVC.
Une fois que le centre d’un goujon en bois ou en métal, ou un objet en
métal a été détecté dans un passage à travers la surface, le goujon Sensor
DW0350 allume les LEDs du centre et sonne une tonalité audible. Un trou
de repérage vous permet d’indiquer facilement le centre du montant.
Sécurité de l'utilisateur
Directives sur la sécurité
Les dénitions suivantes décrivent le niveau de sévérité pour chaque mot-
indicateur. Veuillez lire le manuel et porter attention à ces symboles.
AVERTISSEMENT : Indique une situation potentiellement
dangereuse qui, si elle ne peut être évitée, pourrait entraîner des
blessures graves.
ATTENTION : Indique une situation potentiellement dangereuse
qui, si elle n’est pas évitée, peut entraîner une blessure légère ou
modérée.
AVIS : Indique une pratique non liée à une blessure corporelle qui, si elle
n’est pas évitée, peut entraîner des dommages matériels.
Si vous avez des questions ou des commentaires sur cet outil ou tout
autre outil D
EWALT
®
, visitez le www.DEWALT.com.
AVERTISSEMENT :
Lisez et comprenez toutes les instructions. Ne pas suivre les
avertissements et les instructions de ce manuel peut entraîner une
blessure corporelle grave.
CONSERVEZ CES INSTRUCTIONS
AVERTISSEMENT :
Les informations suivantes sur l’étiquette peuvent être trouvées sur votre
outil pour votre sécurité.
AVERTISSEMENT :
Si l’équipement est utilisé d’une manière non spéciée par
le fabricant, la protection fournie par l’équipement peut être
altérée.
ATTENTION :
Protégez vos yeux. Portez des lunettes de sécurité.
AVERTISSEMENT :
Cet outil n’est pas un instrument de mesure et ne doit pas être
utilisé pour remplacer un voltmètre.
AVERTISSEMENT :
Le voyant DEL ou le symbole détection de ls sous tension
sur l’afchage est simplement un indicateur et, dans certaines
situations, l’option de détection de la tension peut ne pas indiquer
avec précision la présence de la tension dans un mur en cas de
défaillance interne de l’appareil ou d’une mauvaise utilisation
et, par conséquent, ne doit pas être seulement utilisée pour
l’identication de la présence de tensions dangereuses. D'autres
éléments, comme les plans de construction ou l’identication
visuelle des points d’entrée des ls ou des conduits, doivent aussi
être utilisés.
Appliquez toujours les pratiques de sécurité appropriées et
utilisez une méthode de détection séparée pour vous assurer qu’il
n’y a pas de tension avant de commencer à travailler.
AVERTISSEMENT :
Coupez toujours l’alimentation CA lorsque vous travaillez près
des ls.
AVERTISSEMENT :
Les ls blindés ou des ls dans des conduits métalliques, les
boîtiers, les murs métallisés ou les murs denses et épais peuvent
ne pas être détectés.
ATTENTION :
Utilisez un équipement de protection individuel. Portez toujours
une protection oculaire. Selon les conditions de travail, porter un
équipement de protection comme un masque antipoussières, des
chaussures de sécurité antidérapantes, un casque de sécurité et
une protection auditive réduira le risque de blessure corporelle.
AVIS IMPORTANT DE SÉCURITÉ
Assurez-vous de bien détecter les ls sous tension. Tenez toujours le
détecteur de montants DW0350 seulement par la poignée. Saisissez-la
entre vos doigts et votre pouce tout en effectuant un contact avec votre
paume (Figure
C
1
).
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 17 5/21/2019 3:39:43 PM
18
F
Déclaration de conformité du fournisseur
47 CFR § 2,1077 informations de conformité
Identicateur unique: DW0350
Partie responsable – coordonnées des États-Unis
DEWALT
701 East Joppa Road
Towson, Maryland 21286
www.DEWALT.com
Déclaration de la FCC
Cet équipement a été testé et il est conforme aux limites de la classe B des
équipements numériques, conformément à la partie 15 de la réglementation
de la FCC. Ces limites sont prévues pour offrir une protection raisonnable
contre le brouillage préjudiciable dans une installation résidentielle. Cet
équipement génère, utilise, peut émettre de l’énergie de fréquence radio et,
s’il n’est pas installé ou utilisé conformément aux instructions, peut entraîner
un brouillage préjudiciable aux communications radio. Cependant, il n’y a pas
de garantie que ce brouillage se produira dans une installation particulière. Si
cet équipement cause du brouillage préjudiciable à la réception de la radio ou
de la télévision, qui peut être déterminé en allumant et éteignant l’équipement,
l’utilisateur est incité à corriger le brouillage par une ou plusieurs de mesures
suivantes :
- Réorientez ou déplacez l’antenne réceptrice.
- Augmentez l’espace séparant l’équipement du récepteur.
- Branchez l’équipement dans une prise de courant faisant partie d’un circuit
différent (autre que celui auquel le récepteur est branché).
- Consultez le détaillant ou un technicien en radio/télévision pour obtenir
de l’aide.
Canada, Avis d’Innovation, Sciences et Développement
économique Canada (ISDE)
Cet équipement est conforme à la (aux) norme(s) RSS d’Innovation,
Sciences et Développement économique Canada exempte(s) de licence.
Son fonctionnement est assujetti aux deux conditions suivantes : (1)
Cet appareil ne doit pas provoquer d’interférences, et (2) cet appareil
doit accepter les interférences reçues, dont celles pouvant provoquer un
fonctionnement indésirable de l’appareil.
Conformément à la réglementation d’Innovation, Sciences et
Développement économique Canada, le transmetteur radio de cet appareil
peut seulement fonctionner à l’aide d’une antenne du type et du gain
maximum (ou moins) approuvé pour les transmetteurs par Innovation,
Sciences et Développement économique Canada. An de réduire les
interférences radio potentielles aux autres utilisateurs, le type de l’antenne
et son gain doivent être choisis pour que la puissance isotrope rayonnée
équivalente ne dépasse pas le minimum nécessaire à une bonne
communication.
Sécurité Concernant les Piles
AVERTISSEMENT :
Les piles peuvent exploser ou fuir et causer une blessure ou
un incendie. An de réduire ce risque:
Suivez attentivement toutes les instructions et les avertissements des
étiquettes apposées sur les piles et leur emballage.
Insérez toujours les piles correctement en ce qui concerne la polarité
(+ et –), comme indiqué sur la pile et l’équipement.
Ne pas court-circuiter les bornes des piles.
Ne pas recharger les piles jetables.
Ne pas mélanger d’anciennes piles avec des nouvelles. Remplacez
toutes les piles par des piles neuves de même marque et de même type,
en même temps.
Retirez immédiatement les piles à plat et éliminez-les selon les codes
locaux.
Ne pas jeter les piles au feu.
Gardez les piles hors de portée des enfants.
Installer des Piles AAA
Insérez deux nouvelles piles AAA dans le détecteur de montants DW0350.
1.
Au bas du détecteur, soulevez l’attache (Figure
B
1
) pour
déverrouiller le cache du compartiment à piles.
2.
Levez le couvercle (Figure
B
2
)et retirez-le dès qu’il se sépare du
détecteur de montants.
3.
Insérez deux nouvelles piles AAA de haute qualité, en vous assurant de
placer les extrémités - et + de chaque pile comme indiqué à l'intérieur
du compartiment des piles (Figure
B
3
).
4.
Remettez le couvercle sur le détecteur de montants (Figure
B
4
).
• Insérez les deux tiges en haut du couvercle dans les trous dans vers
le haut du compartiment à piles.
• Baissez lentement le couvercle et appuyez vers le bas jusqu’à ce qu’il
se verrouille de façon sécuritaire sur le détecteur de montants.
5.
Appuyez sur ou pour tester le détecteur de montants.
• Le détecteur de montants émet un bip court. Le voyant d’alimentation
et l’icône de batterie sur l’écran LCD doit s’allumer. La LED AC et
toutes les autres icônes sur l’écran LCD doivent s’allumer pendant
une seconde puis s’éteindre.
• Chaque fois que vous appuyez sur
ou , le voyant
d’alimentation vert DEL doit s’allumer pour indiquer que les piles
sont bonnes. Si ce voyant DEL clignote ou ne s’allume pas, changez
les piles. Lorsque l’outil est allumé, le niveau de charge de la pile
apparaît dans la fenêtre d’affichage (Figure
A
7
).
Utiliser le Détecteur de Montants
Le détecteur de montants vous aidera à trouver les montants en bois ou en
métal, une tension C.A. ou des objets métalliques (par exemple, un tuyau)
derrière la cloison sèche.
Le détecteur de montants tiene dos botones. Utilice el botón inferior
(Figure
A
3
) para buscar postes de madera/metal o AC, y utilice el
botón superior (Figure
A
2
) para buscar objetos metálicos (p. ej.,
tubería).
Le détecteur de montants détectera les goujons en bois jusqu’à une
cloison sèche épaisse de 1 “(25mm), et les goujons en métal et la tension
C.A. jusqu’à 1,5” (38mm) cloison sèche épaisse.
Le détecteur de montants détectera un objet en métal ferreux (contient du
fer) jusqu’à 3 “(76,2 mm) de la surface du mur au centre de l’objet.
Le détecteur de montants détectera un objet métallique non ferreux (par
exemple, le cuivre) jusqu’à 2 “(51mm) de la surface du mur au centre de
l’objet.
Lorsque la tension alternative est trouvée, le détecteur de montants émet
un bip court (alternant) et allume la LED AC (Figure
A
5
) et afficher
l’icône AC sur l’écran LCD (Figure
A
4
).
Lorsque le centre d’un goujon est trouvé (ou un objet métallique est à
proximité), le détecteur de montants émet un bip plus long (constant) et
afficher les flèches du centre
sur l’écran LCD (Figure
A
4
)
Lorsque l’alimentation et le centre du montant sont trouvés, le détecteur
de montants alterne entre les bips longs et courts, afficher
et sur
l’écran LCD, et il allume le voyant du AC.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 18 5/21/2019 3:39:44 PM
19
F
Trouver un Montant
1.
Pour tenir le détecteur de montants, placez votre pouce sur un côté du
détecteur de montants, votre index et votre paume au-dessus du centre
du détecteur de montants et le reste de vos doigts de la même main de
l'autre côté du détecteur de montants (Figure
C
1
).
2.
Placez doucement le détecteur de montants à plat contre le mur et
parallèle à une forte ou une fenêtre sur le même mur, ce qui vous
donne une idée de la façon dont les montants sont placés derrière le
mur (Figure
C
2
).
3.
Sans déplacer le détecteur de montants, utilisez votre index pour
appuyer et maintenir (Figure
A
3
). ATTENDRE 1 seconde
jusqu’à ce que toutes les LEDs (sauf la LED Power ) s’éteignent et
toutes les icônes sur l’écran LCD s’éteins sauf le niveau de la batterie.
4.
Pendant que vous appuyez encore , déplacez LENTEMENT le
détecteur de montants vers la gauche ou la droite sur le mur.
5.
Lorsque vous déplacez le détecteur, observez les flèches affichées sur
l’écran LCD et écoutez les bips.
• Si les flèches distantes
apparaissent sur le côté droit de l’écran
LCD (Figure
D
1
), continuez à déplacer le détecteur de montants
vers la droit pour trouver le montant le plus près. Lorsque vous
approchez du montant, apparaît sur l’écran LCD (Figure
D
2
).
• Si les flèches distantes
apparaissent sur le côté gauche de
l’écran LCD, continuez à déplacer le détecteur de montants vers la
gauche pour trouver le montant le plus près. Lorsque vous approchez
du montant, apparaît sur l’écran LCD.
• Si la tension alternative est trouvée à l’intérieur de 6 à 18 po (0,15 m
à 0,5 m) de la position actuelle du détecteur de montants, le voyant
DEL de courant alternatif (Figure
A
5
) s’allumera, apparaissent
de l’écran LCD et vous entendrez bips.
REMARQUE : Des charges d’électricité statique qui peuvent se
développer sur la cloison sèche et d’autres surfaces étendront la zone
de détection de la tension de plusieurs pouces de chaque côté du
l électrique actuel. Cela peut provoquer le capteur de goujon pour
indiquer qu’il a trouvé l’AC en direct quand il n’est pas en fait près
d’un l électrique (Figure
E
1
). Pour aider à localiser la position des
ls, placez votre autre main sur la surface à environ 12 po (30cm) du
détecteur (Figure
E
2
) ou balayez en tenant l’unité à ½ po - 2 po
(13mm - 50mm) de la surface du mur.
6.
Lorsque les flèches du centre apparaissent sur l’écran LCD et que
vous entendez un bip constant, le détecteur de montants a trouvé le
centre d’un montant (Figure
D
3
).
REMARQUE :Si la tension alternative est trouvée près du centre
d’un montant, le voyant DEL de courant alternatif s’allume,
et
apparaît sur l’écran LCD, et le détecteur de montants émettra bips en
alternance (courant alternatif trouvé) suivis d’un bip constant plus long
(centre d’un montant trouvé.
• ARRÊTEZ de déplacer le détecteur de montants et continuez à le
maintenir à la position actuelle.
• ARRÊTEZ d’appuyer sur
.
7.
Par le trou du détecteur de montants (Figure
D
4
), utilisez un crayon
pour indiquer la position actuelle comme le centre du montant.
8.
Pour trouver un autre montant sur le mur, répétez les mêmes étapes.
Recherche d’objets Métalliques
Le détecteur de montants vous permettra de savoir si un objet métallique
(par exemple, un tuyau) est situé derrière le mur à moins de 3” (76.2mm) du
cdétecteur de montants. En mode de détection des métaux, les èches
n’indiquent pas quelle direction déplacer le détecteur de montants
pour trouver le métal.
1.
Pour tenir le détecteur de montants, placez votre pouce sur un côté du
détecteur de montants, votre index et votre paume au-dessus du centre
du détecteur de montants et le reste de vos doigts de la même main de
l’autre côté du détecteur de montants (Figure
C
1
).
2.
Placez doucement le détecteur de montants à plat contre le mur et
parallèle à une forte ou une fenêtre sur le même mur, ce qui vous
donne une idée de la façon dont les montants sont placés derrière le
mur (Figure
C
2
).
3.
Sans déplacer le détecteur de montants, utilisez votre index pour
appuyer et maintenir
(Figure
A
2
). Après 1 seconde, toutes
les LEDs (sauf la LED Power
) s’éteignent et toutes les icônes sur
l’écran LCD s’éteins sauf le niveau de la batterie et
.
4.
Pendant que vous appuyez encore , déplacez LENTEMENT le
détecteur de montants vers la gauche ou la droite sur le mur.
5.
Lorsque vous déplacez le détecteur de montants, observez les flèches
affichées sur l’écran LCD.
• Quand
et apparaissent sur l’écran LCD, déplacez lentement
le détecteur vers la droite ou vers la gauche pour trouver l’objet
métallique le plus proche (Figure
F
1
).
• Quand
et apparaissent sur l’écran LCD, vous saurez
que vous déplacez le capteur plus près de l’objet métallique (Figure
F
2
).
6.
Lorsque les flèches du centre apparaissent sur l’écran LCD et
que vous entendez un bip constant, le détecteur a trouvé un objet
métallique à moins de 76,2 mm (3 “) à gauche ou à droite de la position
actuelle (Figure
F
3
).
• ARRÊTEZ de déplacer le détecteur et continuez à le maintenir à la
position actuelle.
• ARRÊTEZ d’appuyer sur
.
7.
Par le trou du détecteur de montants (Figure
F
4
), utilisez un crayon
pour indiquer la position actuelle.
• L’objet métallique peut être à moins de 3 “(76,2 mm) à gauche ou à
droite de la marque.
• Pour la position exacte de l’objet métallique, vous devez vous référer
aux dessins de construction.
8.
Pour trouver un autre objet métallique, répétez les mêmes étapes.
Entretien
Lorsque le détecteur de montants n’est pas utilisé, nettoyez les pièces
extérieures avec un linge humide, essuyez-le avec un linge sec doux pour
vous assurer qu’il est sec.
Même si l’extérieur du détecteur de montants est résistant aux solvants,
NE JAMAIS utiliser de solvants pour nettoyer le détecteur de montants.
Entreposez le détecteur de montants dans un endroit propre à une
température entre -55 ˚C (-67 ˚F) et 70 ˚C (158 ˚F).
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 19 5/21/2019 3:39:44 PM
20
F
Dépannage
Le voyant DEL clignote
Si le voyant DEL clignote (et que le niveau de la batterie clignote sur
l’écran LCD), la pile est faible.
Vériez les piles AAA pour vous assurer que :
• Chaque pile est installée correctement, selon + et indiqués
à l’intérieur du compartiment des piles.
• Les contacts des piles sont propres et sans rouille ou corrosion.
• Ce sont de nouvelles piles de haute qualité afin de réduire le risque
de fuite des piles.
Assurez-vous que les piles AAA fonctionnent bien. En cas de doute,
essayer d’installer de nouvelles piles.
Le voyant DEL ne s'allume pas
Si la LED ne s’allume pas, ou si la LED s’allume pendant 1 s, puis
s’éteint, il n’y a pas d’alimentation de la pile.
Installez deux nouvelles piles AAA de marque et de haute qualité dans
le détecteur.
Assurez-vous que chaque pile est installée correctement, selon + et
indiqués à l’intérieur du compartiment des piles.
Le détecteur de montants ne trouve pas de montants
Assurez-vous que les piles fonctionnent.
Assurez-vous que vous avez placé le détecteur de montants sur un mur
fait d’une cloison sèche ou un autre matériau de construction courant. Le
détecteur de montants ne fonctionnera pas sur les murs faits de béton,
mortier, roche, briquetage, plâtre, tapis, matériaux à base de feuilles
d’aluminium, surfaces métalliques ou carreaux de céramique.
Assurez-vous que vous avez placé le détecteur de montants à plat
contre le mur, le détecteur de montants est en position verticale (parallèle
à une porte ou une fenêtre) et que vous avez appuyé et maintenu
(Figure
A
3
) pendant que vous déplacez LENTEMENT le détecteur de
montants contre le mur.
Assurez-vous que le mur n’est pas trop épais. Le détecteur de montants
détectera les goujons en bois jusqu’à une cloison sèche épaisse de 1”
(25mm), et les goujons en métal et la tension C.A. jusqu’à 1,5” (38mm)
cloison sèche épaisse.
Assurez-vous que le mur a une surface lisse.
Assurez-vous que la température respecte la plage de fonctionnement
et l’humidité relative indiquées.
Le détecteur de montants ne trouve pas d’objets
Métalliques
Assurez-vous que les piles fonctionnent.
Assurez-vous que vous avez placé le détecteur de montants sur un mur
fait d’une cloison sèche ou un autre matériau de construction courant. Le
détecteur de montants ne fonctionnera pas sur les murs faits de béton,
mortier, roche, briquetage, plâtre, tapis, matériaux à base de feuilles
d’aluminium, surfaces métalliques ou carreaux de céramique.
Assurez-vous que vous avez placé le détecteur de montants à plat
contre le mur, le détecteur de montants est en position verticale (parallèle
à une porte ou une fenêtre) et que vous avez appuyé et maintenu
(Figure
A
2
) pendant que vous déplacez LENTEMENT le détecteur de
montants contre le mur.
Assurez-vous que le mur n’est pas trop épais. Le détecteur de montants
détectera Non-Ferrous Metal (p. ex., cuivre) jusqu’à 2 po (51mm), et les
le métal ferreux (contient du fer) jusqu’à 3 po (76.2mm) cloison sèche
épaisse.
Assurez-vous que le mur a une surface lisse.
Assurez-vous que la température respecte la plage de fonctionnement
et l’humidité relative indiquées.
Réparations
Remarque : Désassembler l’outil annulera toute garantie sur le produit.
Pour assurer la SÉCURITÉ et la FIABILITÉ du produit, les réparations,
l’entretien et l’ajustement doivent être effectués par des centres de services
autorisés. Les réparations ou l’entretien effectué par du personnel non
qualié peuvent entraîner un risque de blessure. Pour localiser le centre de
service D
EWALT le plus près, consultez www.DEWALT.com.
Garantie
Allez à www.DEWALT.com pour obtenir des informations sur la garantie.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 20 5/21/2019 3:39:45 PM
21
F
Caractéristiques
DW0350
Détecter les montants en bois cloison sèche d’une épaisseur allant jusqu’à 1 po (25 mm)
Détecter les montants en métal cloison sèche d’une épaisseur allant jusqu’à 1,5 po (38 mm)
Détecter les ls de courant alternatif
110 V @ 60 Hz (220 V @ 50 Hz)
jusqu’à 2 po (50,8 mm) derrière la surface du mur
d’une distance de 6 à 18 po (0,15 à 0,5 m) le voyant de courant alternatif s’allumera
Détecter le métal ferreux (contient du fer) jusqu’à 3 po (76.2mm) derrière la surface du mur
au centre de l’objet métallique (tuyau)
Detect Non-Ferrous Metal (p. ex., cuivre) jusqu’à 2 po (51mm) derrière la surface du mur
au centre de l’objet métallique (tuyau)
Précision - Centre du montant en bois +/- 1/4 po (6.4 mm) sous une cloison sèche d’une épaisseur de 1/2 à 1 po (12,7 à 25 mm)
Précision - Centre du montant en métal +/- 1/4 po (6.4 mm) sous une cloison sèche d’une épaisseur de 1/2 à 1,5 po (12,7 à 38
mm)
Précision - Détection d’objets métalliques +/- 3 po (76.2mm)
Source de l'alimentation 2 piles AAA (1,5 V) (3 V CC)
Durée de vie de la pile
< 10 heures d’utilisation continue à < 2,4 V (+/- 0.3V),
le voyant DEL d’alimentation clignotera pour indiquer que la pile est faible
Calibrage automatique Oui
S’éteint automatiquement lorsque vous relâchez le
bouton Marche
Oui
Surface non marquante Oui
Humidité relative 35 % à 55 %
Température de fonctionnement 32°F à 122°F (0°C à 50°C)
Température d'entreposage -4°F à 150°F (-20°C à 66°C)
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 21 5/21/2019 3:39:45 PM
22
PT
Índice
• Informações sobre o detector
• Segurança do usuário
• Segurança da bateria
• Como instalar baterias AAA
• Usando o detector
• Manutenção
• Solução de problemas
• Assistência técnica e reparos
• Garantia
• Especicações
Informações Sobre o Detector
O detector DW0350 usa sinais eletrônicos para localizar o centro dos
pregos de madeira ou metal, os AC vivos, ou objetos metálicos (por
exemplo, tubulação) na parede ou outros materiais de construção comuns.
OBSERVAÇÃO:
O detector não detecta objetos em concreto, argamassa, blocos, tijolos,
gesso, carpetes, materiais com face de alumínio, superfícies metálicas ou
revestimentos cerâmicos.
O detector não detectará tubos de plástico ou PVC.
Uma vez que o centro de um pino de madeira ou de metal ou um objeto
de metal foi detectado depois de passar através da superfície, o detector
DW0350 acende os LEDs centrais e emite um sinal sonoro. Um círculo da
marcação permite que você anote facilmente a posição atual na parede.
Segurança do Usuário
Guia de segurança
As denições abaixo descrevem o nível de gravidade representado para
cada palavra de sinal. Por favor, leia o manual e preste atenção nestes
símbolos.
AVISO: Indica uma situação potencialmente perigosa que, se não
for evitada, poderá resultar em ferimentos graves.
CUIDADO: Indica uma situação potencialmente perigosa que, se
não for evitada, talvez resulte em ferimentos leves ou moderados.
NOTA: Indica uma prática não relacionada a uma lesão corporal, a qual,
se não evitada, poderá causar danos materiais.
Se tiver perguntas ou comentários sobre esta ou outra ferramenta da
DEWALT
®
, visite a página www.DEWALT.com.
AVISO:
Leia e entenda todas as instruções. O descumprimento dos
avisos e das instruções deste manual pode causar sérias lesões
corporais.
GUARDE ESTAS INSTRUÇÕES
AVISO:
As seguintes informações da etiqueta podem ser encontradas em sua
ferramenta para sua segurança.
CUIDADO:
Proteja seus olhos. Use óculos de segurança.
AVISO:
Esta ferramenta não é um dispositivo de medição e não deve
ser usada como substituto de um voltímetro.
AVISO:
O símbolo LED ou de detecção de os mostrado no visor é apenas
um indicador e em algumas situações, a opção de detecção de
voltagem pode não indicar com exatidão a presença de tensão em
uma parede, no caso de falha interna do dispositivo ou operação
inadequada. Portanto, não se deve ser apenas conar unicamente
nele para identicar o risco de voltagens. Outras indicações, como
desenhos técnicos da construção ou identicação visual de ações
ou conduítes nos pontos de entrada devem também ser utilizados.
Sempre siga as instruções de segurança adequadas e use um
método de detecção separado para vericar se os cabos estão
desligados antes de iniciar o trabalho.
AVISO:
Sempre desligue a energia AC ao trabalhar perto da ação.
AVISO:
Fios blindados ou os em conduítes metálicos, invólucros,
paredes metalizadas ou paredes grossas e densas podem não ser
detectados.
CUIDADO:
Use equipamento de proteção pessoal. Sempre use proteção
ocular. Dependendo das condições de trabalho, use equipamentos
de proteção pessoal, como máscara contra a poeira, sapatos de
segurança antideslizantes, capacete e proteção auditiva para
reduzir o risco de lesões corporais.
AVISO IMPORTANTE DE SEGURANÇA
Garanta a detecção adequada de os energizados. Sempre segure
o detector DW0350 somente pela empunhadura. Segure-o entre os dedos
e o polegar encostando na palma da mão (Figura
C
1
).
Declaração de conformidade do fornecedor
47 CFR § 2,1077 informações de conformidade
Identicador exclusivo: DW0350
Parte responsável – informações de contato dos Estados Unidos
DEWALT
701 East Joppa Road
Towson, Maryland 21286
www.DEWALT.com
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 22 5/21/2019 3:39:46 PM
23
PT
Declaração da FCC
Este equipamento foi testado e está em conformidade com os limites
de um dispositivo digital de classe B, em conformidade com a parte 15
das regras da FCC. Estes limites foram concebidos para fornecer uma
proteção razoável contra interferências nocivas em uma instalação
residencial. Este equipamento gera, utiliza e pode irradiar radiofrequência
e, se não for instalado e utilizado de acordo com as instruções, pode
causar interferências nocivas nas comunicações por radiocomunicação.
Contudo, não há garantia que não ocorram interferências em uma
instalação especíca. Se este equipamento realmente causar interferências
prejudiciais na recepção de televisão ou rádio, o que pode ser vericado
ao ligar e desligar o equipamento, o usuário deve tentar corrigir as
interferências realizando uma ou mais das seguintes medições:
- Reoriente ou reposicione a antena de recepção em outra posição.
- Aumente a distância entre o equipamento e o receptor.
- Ligue o equipamento na tomada em um circuito diferente (não deve ser
o mesmo circuito ao qual o receptor está ligado).
- Consulte o fornecedor ou um técnico de rádio/televisão para obter ajuda.
Segurança da Bateria
AVISO:
As baterias podem explodir ou vazar substâncias, e causar
ferimentos graves ou incêndio. Para reduzir o risco:
Siga SEMPRE todas as instruções e avisos indicados na etiqueta e na
embalagem das baterias.
Sempre insira as baterias corretamente em relação à polaridade (+ e –),
como marcado na bateria e no equipamento.
Não provoque um curto-circuito nos terminais das baterias.
Não carregue baterias descartáveis.
Não misture baterias novas e antigas. Substitua todas as baterias ao
mesmo tempo por novas da mesma marca e do mesmo tipo.
Retire as baterias descarregadas imediatamente e descarte-as de acordo
com os códigos locais.
Não descarte as baterias no fogo.
Mantenha as baterias longe do alcance das crianças.
Como Instalar Baterias AAA
Carregue as baterias novas no detector AAA no DW0350.
1.
Na parte inferior do sensor de vigas, levante a patilha (Figura
B
1
)
para desbloquear a tampa do compartimento da bateria.
2.
Mova a tampa para cima (Figura
B
2
) e a remova assim que ela se
separar do detector.
3.
Insira duas pilhas AAA novas de marca de alta qualidade, certificando-
se de posicionar as extremidades - e + de cada bateria como no
compartimento (Figura
B
3
).
4.
Coloque a tampa de volta no detector (Figura
B
4
).
• Insira os dois pinos na parte superior da tampa nos furos perto da
parte superior do compartimento da bateria.
• Abaixe lentamente a tampa e pressione para baixo até que a trava
se trave rmemente no detector.
5.
Pressione ou para testar o detector.
• O detector emitirá alarmes sonoros curtos. O LED de alimentação e o
ícone da bateria no ecrã LCD deve ligar. O LED AC e todos os outros
ícones na tela LCD devem iluminar por um segundo e, em seguida,
desligue.
• Sempre que pressionar
ou , o LED de energia verde se
acenderá para indicar que as baterias estão boas. Se este LED piscar
ou não acender, troque as baterias. Quando a ferramenta estiver
ligada (ON), o nível de carga das baterias aparece no display (Figura
A
7
).
Como Usar o Detector
O detector o ajudará a encontrar pinos de madeira ou metal, voltagem AC
presente, e objetos metálicos (por exemplo, tubulação) em uma parede.
O detector tem dois botões. Usuário o botão inferior (Figura
A
3
) para
procurar por pregos de madeira/metal ou AC, e use o botão superior
(Figura
A
2
) para procurar objetos metálicos (por exemplo, pipe).
O detector detectará pregos de madeira com o drywall grosso de até 1“
(25mm), e os pregos do metal e a tensão de C.A. com até 1,5“ (38mm) o
drywall grosso.
O detector detectará um objeto de metal ferroso (contém ferro) até 3“
(76,2 mm) da superfície da parede para o centro do objeto.
O detector detectará. O detector detectará um objeto metálico não ferroso
(por exemplo, cobre) até 2“ (51 mm) da superfície da parede até o centro
do objeto.
Quando a tensão AC for encontrada, o detector emitirá alarmes sonoros
curtos (alternados) e acenderá o LED AC (Figura
A
5
) e mostrar o
ícone AC na tela LCD (Figura
A
4
).
Quando o centro de um pino for encontrado (ou um objeto metálico
está nas proximidades), o detector emitirá um sinal sonoro mais longo
(constante) e exibir as setas do centro
na tela LCD (Figure
A
4
).
Quando o AC energizado e o centro de um pino forem encontrados, o
detetor alterará entre os bipes longos e curtos, exibir
e na tela
LCD, e iluminar o LED AC.
Como Encontrar um Pino
1.
Para segurar o detector, coloque o polegar em um lado do detector,
o dedo indicador e a palma da mão sobre o centro do detector,
e o resto dos dedos na mesma mão do outro lado do detector (Figura
C
1
).
2.
Coloque delicadamente o detector contra a parede e paralelamente
a uma porta ou janela na mesma parede. Isso lhe dará uma indicação
de como os metais estão posicionados atrás da parede (Figura
C
2
).
3.
Sem mover o detector, use o dedo indicador para pressionar e segurar
(Figura
A
3
). AGUARDE 1 seg até que todos os LEDS (exceto
o LED de energia) desligam e todos os ícones na tela LCD desligar,
exceto o nível da bateria.
4.
Enquanto estiver pressionando , LENTAMENTE mova o detector
para a esquerda ou para a direita na parede.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 23 5/21/2019 3:39:47 PM
24
PT
5.
Ao mover o detector, observe as setas exibidas na tela LCD e ouça os
alarmes sonoros.
• Se as setas remotas
aparecerem no lado direito da tela LCD
(Figura
D
1
), continue movendo o detector para a direita para
encontrar o pino mais próximo. Como você chegar mais perto do
pino,
aparece na tela LCD (Figura
D
2
).
• Se as setas remotas
aparecerem no lado esquerdo da tela LCD,
continue movendo o detector para a esquerda para encontrar o pino
mais próximo. Como você chegar mais perto do pino, aparece
na tela LCD.
• Se a tensão AC for encontrada dentro de 12”- 18” (0,3 m - 0,5 m) da
posição atual do detector, o LED AC acenderá,
aparecerem no do
ecrã LCD, e você ouvirá alarmes sonoros curtos.
NOTA: As cargas elétricas estáticas, que podem se desenvolver
em paredes de gesso e outras superfícies, espalharão a área de
detecção de voltagem em muitas polegadas para todos os lados do
o elétrico em questão. Isto pode fazer com que o detector indique
que encontrou C.A. viva quando não está realmente perto de um
o elétrico (Figura
E
1
). Para ajudar a localizar a posição do o,
coloque a outra mão na sua superfície aproximadamente 12’’ (30cm)
do sensor (Figura
E
2
) ou faça uma varredura segurando a unidade
½ - 2 (13mm - 50mm) da superfície da parede.
6.
Quando as setas do centro aparecem na tela LCD e você ouvir
um sinal sonoro constante, significa que o detector encontrou o centro
de um pino (Figura
D
3
).
NOTA: Se a tensão AC for encontrada perto do centro de um
pino, o LED AC acenderá,
e aparecerem no do ecrã LCD,
e o detector emitirá o alarme sonoro curto alternado (AC encontrado) de
pois outro mais constante e longo (centro do pino encontrado).
• PARE de mover o detector e continue a segurá-la na posição atual.
• PARE de pressionar
.
7.
Passando pelo círculo no detector (Figura
D
4
), marque com um
lápis a posição atual como o centro do pino.
8.
Para encontrar outro pino na parede, repita os mesmos procedimentos.
Como Encontrar Objetos do Metal
O detector vai deixar você saber se um objeto de metal (por exemplo, um
tubo) está localizado atrás da parede dentro de 3” do detector. No modo
de detecção de metal, as setas não indicam qual direção mover o
detector para encontrar metal.
1.
Para segurar o detector, coloque o polegar em um lado do detector,
o dedo indicador e a palma da mão sobre o centro do detector,
e o resto dos dedos na mesma mão do outro lado do detector (Figura
C
1
).
2.
Posicione o detector contra a parede e paralelamente a uma porta ou
janela na mesma parede. Isso lhe dará uma indicação de como os
metais estão posicionados atrás da parede (Figura
C
2
).
3.
Sem mover o detector, use o dedo indicador para pressionar e segurar
(Figura
A
2
). Após 1 seg, todos os LEDS (exceto o LED de
energia) desligam e todos os ícones na tela LCD desligar, exceto o
nível da bateria e
.
4.
Enquanto estiver pressionando , LENTAMENTE mova o detector
para a esquerda ou para a direita na parede.
5.
Ao mover detector, observe as setas exibidas na tela LCD.
• Se
e aparecerem no do ecrã LCD, mova o detector para a
direita ou para a esquerda para encontrar o objeto metálico (Figura
F
1
).
• Se
e aparecerem no do ecrã LCD, você vai saber que
você está movendo o detector mais perto do objeto metálico (Figura
F
2
).
6.
Quando as setas do centro aparecem na tela LCD e você ouvir
um sinal sonoro constante, significa que o detector encontrou objeto
metálico dentro de 3 “(76,2 mm) à esquerda ou à direita da posição
atual (Figura
F
3
).
• PARE de mover o detector e continue a segurá-la na posição atual.
• PARE de pressionar
.
7.
Passando pelo círculo no detector (Figura
F
4
), marque com um
lápis a posição atual.
• O objecto metálico pode estar dentro de 3 “(76,2 mm) à esquerda ou
à direita da marca.
• Para a posição exata do objeto metálico, você deve referir-se a
desenhos de construção.
8.
Para encontrar outro objeto metálico na parede, repita os mesmos
procedimentos.
Manutenção
Quando o detector não estiver em uso, limpe as partes externas com um
pano úmido, limpe o detector com um pano macio e seco para ter certeza
de que esteja seco.
Embora o exterior do detector seja resistente a solventes, NUNCA use
solventes para limpar o detector.
Armazene o detector em um local limpo a uma temperatura entre -67 ˚F
(-55 ˚C) e 158 ˚F (70 ˚C).
Solução de Problemas
O LED está piscando
Se o LED de alimentação está piscando (e o nível da bateria no ecrã LCD
está piscando), a bateria está acabando.
Verique as baterias AAA para garantir que:
• Cada bateria esteja instalada corretamente, de acordo com + e -
dentro do compartimento da bateria.
• Os contatos da bateria estejam limpos sem ferrugem ou corrosão.
• As baterias sejam novas e de alta qualidade para reduzir as chances
de vazamento da bateria.
Certique-se de que as pilhas AAA estejam em boas condições de
funcionamento. Em caso de dúvida, tente instalar novas baterias.
O LED não liga
Se o LED de alimentação não ligar, ou o LED de alimentação acender
durante 1 seg e, em seguida, desligar, não existe energia da bateria.
Instale duas baterias novas, de alta qualidade e de marca renomada AAA
no detector.
Certique-se de que cada bateria esteja instalada corretamente, de
acordo com + e - esteja dentro do compartimento da bateria.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 24 5/21/2019 3:39:48 PM
25
PT
O detector não está encontrando pinos
Certifique-se de que as baterias estejam funcionamento.
Certifique-se de ter colocado o detector em uma parede ou outro material
de construção comum. O detector não funcionará em paredes de
concreto, argamassa, blocos, tijolos, gesso, carpetes, materiais com face
de alumínio, superfícies metálicas ou revestimentos cerâmicos.
Certique-se de que tenha colocado o detector contra a parede,
o detector esteja na posição vertical (paralelo a uma porta ou janela),
e que você esteja pressionando e segurando
(Figura
A
3
),
movendo ao mesmo tempo o detector LENTAMENTE contra a parede.
Certique-se de que a parede não seja muito grossa. O DW0100 pode
ser usado em paredes de até < 0,75” (19 mm) de espessura e o DW0150
pode ser usado em parede com menos de <1,5” (38 mm) espessura.
Certique-se de que a parede tenha uma superfície lisa.
Cerique-se que a temperatura esteja dentro da faixa operacional
especicada e da umidade relativa.
O detector não está encontrando Objetos do Metal
Certifique-se de que as baterias estejam funcionamento.
Certifique-se de ter colocado o detector em uma parede ou outro material
de construção comum. O detector não funcionará em paredes de
concreto, argamassa, blocos, tijolos, gesso, carpetes, materiais com face
de alumínio, superfícies metálicas ou revestimentos cerâmicos.
Certique-se de que tenha colocado o detector contra a parede,
o detector esteja na posição vertical (paralelo a uma porta ou janela),
e que você esteja pressionando e segurando
(Figura
A
2
),
movendo ao mesmo tempo o detector LENTAMENTE contra a parede.
Certique-se de que a parede não seja muito grossa. O DW0350 pode
ser usado para detect não ferrosos (por exemplo, cobre) metais em
paredes de até 2 “(51mm) de espessura e metal ferroso (contem o ferro)
até 3 “(76,2 mm) espessura.
Certique-se de que a parede tenha uma superfície lisa.
Cerique-se que a temperatura esteja dentro da faixa operacional
especicada e da umidade relativa.
Assistência Técnica e Reparos
Nota: Desmontar o instrumento anula todas as garantias do produto.
Para garantir a SEGURANÇA e CONFIABILIDADE do produto, os reparos,
a manutenção e os ajustes devem ser realizados por centros de assistência
técnica autorizados. A assistência técnica ou manutenção realizada por
pessoal não qualicado pode oferece riscos de lesões. Para localizar um
centro de assistência técnica DEWALT MAIS PRÓXIMO DE VOCÊ, acesse
www.DEWALT.com.
Garantia
Acesse www.DEWALT.com para obter as informações de garantia mais
recentes.
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 25 5/21/2019 3:39:49 PM
26
PT
Especicações
DW0350
Detectar pinos de madeira paredes de até 1” (25 mm) de espessura
Detectar pinos de metal paredes de até 2” (51 mm) de espessura
Detectar Fio AC energizado 110V @ 60 Hz (220V
@ 50Hz)
até paredes de 2” (51 mm) espessura de uma distância de 6”-18”
(0,15 m - 0,5 m) o LED AC ascenderá
Detecte o metal ferroso (contem o ferro) até 3 “(76,2 mm) da superfície da parede
para o centro do objeto metálico (pipe)
Detecte metais não ferrosos (por exemplo, cobre) até 2 “(51mm) da superfície da parede
para o centro do objeto metálico (pipe)
Exatidão - Centro do pino de madeira parede de +/- 1/4” (6.4 mm) menor que 1/2” - 1,5” (12,7 mm - 38 mm) de espessura
Exatidão - Centro do pino de metal parede de +/- 1/4” (6.4 mm) menor que 1/2” - 1,5”
(12,7 mm - 38 mm) de espessura
Exatidão - Detecção de rastreamento de metal +/- 3” (76.2mm)
Fonte de potência 2 AAA (1.5V) baterias de tamanho (3V DC)
Vida da bateria
< 10 horas de uso contínuo a <2,4 V (+/- 0,3 V),
energia de LED piscará para indicar bateria fraca
Calibração automática Sim
Desligamento automático ao soltar o botão Ligar Sim
Não causa danos à superfície Sim
Umidade relativa 35% - 55%
Temperatura Operacional 32°F to 122°F (0°C to 50°C)
Temperatura de armazenamento -4°F to 150°F (-20°C to 66°C)
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 26 5/21/2019 3:39:49 PM
Notes:
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 27 5/21/2019 3:39:49 PM
© 2019 DEWALT Industrial Tool Co.,
701 East Joppa Road,
Towson, MD 21286
See product for country of origin statement.
N663828
May 2019
DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 28 5/21/2019 3:39:49 PM

Transcripción de documentos

E ES DW0350 Stud Sensor F PT www.DEWALT.com Please read these instructions before operating the product. DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 1 5/21/2019 3:39:22 PM Figures A 6 4 1 < 25% 5 2 7 3 100% 75% 50% 25% < 25% 2 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 2 5/21/2019 3:39:24 PM B C 1 2 3 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 3 5/21/2019 3:39:25 PM Figures D 4 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 4 5/21/2019 3:39:28 PM E 1 2 AC 6” - 18” 12” AC 5 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 5 5/21/2019 3:39:29 PM Figures F ~ ~ 6 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 6 5/21/2019 3:39:34 PM Contents • Stud Sensor Information • User Safety • Battery Safety • Installing AAA Batteries • Using the Stud Sensor • Maintenance • Troubleshooting • Service and Repairs • Warranty • Specifications Stud Sensor Information The Stud Sensor DW0350 uses electronic signals to locate the center of wood or metal studs, live AC wires, or metal objects (e.g., pipe) through drywall or other common building materials. PLEASE NOTE: • The stud sensor will not detect objects in concrete, mortar, block, brick work, plaster, carpeting, foil-faced materials, metallic surfaces, or ceramic tile. • The stud sensor will not detect plastic or PVC pipes. Once the center of a wood or metal stud, or a metal object has been detected in one pass across the surface, the Stud Sensor DW0350 turns on the center LEDs and sounds an audible tone. A marking hole allows you to easily note the current position on the wall. User Safety Safety Guidelines The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.   WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.  AUTION: Indicates a potentially hazardous situation which, if not C avoided, may result in minor or moderate injury. NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage. If you have any questions or comments about this or any DEWALT® tool, go to www.DEWALT.com. WARNING: Read and understand all instructions. Failure to follow the warnings and instructions in this manual may result in serious personal injury. SAVE THESE INSTRUCTIONS WARNING: The following label information can be found on your tool for your safety. E WARNING: If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. CAUTION: Protect your eyes. Wear safety goggles. WARNING: This tool is not a measuring device and should not be used as a substitute for a voltmeter. WARNING: The LED or Live Wire Detection symbol on the display is just an indicator and in some situations the voltage detection option may not accurately indicate the presence of voltage in a wall in the event of internal device failure or improper operation, and therefore should not be solely relied upon for identification of the presence of hazardous voltages. Other evidence, such as construction blueprints or visual identification of wiring or conduit entry points should also be utilized. Always follow proper safety practices and use a separate detection method to verify a de-energized condition prior to commencing work. WARNING: Always turn off AC power when working near wiring. WARNING: Shielded wires or wires in metal conduits, casings, metalized walls, or thick, dense walls may not be detected. CAUTION: Use personal protective equipment. Always wear eye protection. Depending on the work conditions, wearing protective equipment such as a dust mask, non-skid safety shoes, hard hat, and hearing protection will reduce the risk of personal injury. IMPORTANT SAFETY NOTICE Ensure proper detection of live wires. Always hold the Stud Sensor DW0350 in the handle area only. Grasp between fingers and thumb while making contact with your palm (Figure C 1 ). 7 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 7 5/21/2019 3:39:34 PM Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information E Installing AAA Batteries Unique Identifier: DW0350 Responsible Party – U.S. Contact Information DEWALT 701 East Joppa Road Towson, Maryland 21286 www.DEWALT.com Load two new AAA batteries in the DW0350 stud sensor. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a different circuit (not the circuit to which the receiver is connected). - Consult the dealer or an experienced radio/TV technician for help. Canada, Industry Canada (IC) Notices This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Battery Safety WARNING: Batteries can explode, or leak, and can cause injury or fire. To reduce this risk: • Carefully follow all instructions and warnings on the battery label and package. • A  lways insert batteries correctly with regard to polarity (+ and –), as marked on the battery and the equipment. • Do not short battery terminals. • Do not charge disposable batteries. 1. On the bottom of the stud sensor, lift up the latch (Figure unlock the battery compartment cover. 2. Move the cover upward (Figure from the stud sensor. 3. Insert two new, high-quality AAA batteries, making sure to position the - and + ends of each battery as noted inside the battery compartment (Figure B 3 ). 4. Place the cover back on the stud sensor (Figure B 2 B 1 ) to ) and remove it once it separates B 4 ). • Insert the two pins at the top of the cover into the holes near the top of the battery compartment. • Slowly lower the cover and press down until the latch locks securely on the stud sensor. 5. Press or to test the stud sensor. • The stud sensor should sound one short beep. The Power LED and the battery icon on the LCD screen should turn on.The AC LED and all the other icons on the LCD screen should illuminate for a second and then turn off. or , the green Power LED should • Whenever you press illuminate to indicate that the batteries are good. If this LED blinks or does not illuminate, change the batteries. When or is pressed, the battery level appears on the LCD screen (Figure A 7 ). Using the Stud Sensor The DW0350 stud sensor will help you find wood or metal studs, AC voltage, or metal objects (e.g., pipe) behind drywall. • The stud sensor has two buttons. Use the bottom button (Figure A 3 ) to search for wood/metal studs or AC, and use the top button (Figure A 2 ) to search for metal objects (e.g., pipe). • The stud sensor will detect wood studs through up to 1” (25mm) thick drywall, and metal studs and AC voltage through up to 1.5” (38mm) thick drywall. • The stud sensor will detect a ferrous metal object (contains iron) up to 3” (76.2mm) from the surface of the wall to the center of the object. • The stud sensor will detect a non-ferrous metal object (e.g., copper) up to 2” (51mm) from the surface of the wall to the center of the object. • When AC voltage is found, the stud sensor will sound short (alternating) beeps, light the AC LED (Figure A 5 ), and display the AC icon on the LCD screen (Figure A 4 ). • When the center of a stud is found (or a metal object is nearby), the stud sensor will sound one longer (constant) beep and display the center on the LCD screen (Figure A 4 ). arrows • When live AC and the center of a stud are both found, the stud sensor will on the alternate between the long and short beeps, display and LCD screen, and illuminate the AC LED. • Do not mix old and new batteries. Replace all batteries at the same time with new batteries of the same brand and type. • Remove dead batteries immediately and dispose of per local codes. • Do not dispose of batteries in fire. • Keep batteries out of reach of children. 8 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 8 5/21/2019 3:39:36 PM Finding Metal Objects Finding a Stud E 1. To hold the stud sensor, place your thumb on one side of the stud sensor, your pointer finger and your palm over the center of the stud sensor, and the rest of your fingers on the same hand on the other side of the stud sensor (Figure C 1 ). The stud sensor will let you know if a metal object (e.g., a pipe) is located behind the wall within 3” (76.2mm) of the stud sensor. In metal detection mode, the arrows do not indicate which direction to move the stud sensor to find metal. 2. Gently place the stud sensor flat against the wall and parallel to a door or window on the same wall, which gives you an indication of how the studs are positioned behind the wall (Figure C 2 ). 1. 3. Without moving the stud sensor, use your pointer finger to press and hold (Figure A 3 ). WAIT 1 sec until all the LEDs (except the Power LED) turn off and all icons on the LCD screen turn off except the battery level. To hold the stud sensor, place your thumb on one side of the stud sensor, your pointer finger and your palm over the center of the stud sensor, and the rest of your fingers on the same hand on the other side of the stud sensor (Figure C 1 ). 2. Position the stud sensor flat against the wall and parallel to a door or window on the same wall, which gives you an indication of how the studs are positioned behind the wall (Figure C 2 ). 4. While still pressing the right on the wall. 3. 5. As you move the stud sensor, watch the stud sensor arrows displayed on the LCD screen and listen for beeps. Without moving the stud sensor, use your pointer finger to press and hold (Figure A 2 ). WAIT 1 sec until all the LEDs (except the Power LED) turn off and all icons on the LCD screen turn off except the battery level and . 4. While still pressing the right on the wall. 5. As you move the stud sensor, watch the arrows displayed on the LCD screen. , SLOWLY move the stud sensor to the left or appears on the right side of the LCD screen (Figure D 1 ), • If continue moving the stud sensor to the right to find the nearest stud. As you get closer to the stud, will appear on the LCD screen (Figure D 2 ). appears on the left side of the LCD screen, continue moving • If the stud sensor to the left to find the nearest stud. As you get closer to the stud, will appear on the LCD screen. • If live AC voltage is found within 6”-18” (.15m - .5m) of the stud sensor’s current position, the AC LED will illuminate, will appear on the LCD screen, and you will hear short beeps. NOTE: Static electrical charges that can develop on drywall and other surfaces will spread the voltage detection area many inches on each side of the actual electrical wire. This can cause the stud sensor to indicate that it has found live AC when it is not actually near an electrical wire (Figure E 1 ). To aid in locating the wire position, place your other hand on the surface approximately 12” (30cm) from the stud sensor (Figure E 2 ), or hold the stud sensor ½” - 2” (13mm 50mm) away from the wall surface. 6. and appear on the LCD screen, slowly move the • When stud sensor to the left or right to find the metal object (Figure F 1 ). and appear on the LCD screen, you will know that • When you are moving the stud sensor closer to the metal object (Figure F 2 ). 6. • STOP moving the stud sensor and continue to hold it at the current position. • STOP pressing . 7. Through the hole on the stud sensor (Figure D 4 ) use a pencil to mark the current position on the wall as the center of the stud. 8. To find another stud on the wall, repeat the same steps. When the center arrows appear on the LCD screen (Figure A 4 ) and you hear a constant beep, the stud sensor has found a metal object within 3” (76.2mm) to the left or right of the current position (Figure F 3 ). • STOP moving the stud sensor and continue to hold it at the current position. • STOP pressing 7. When the center arrows appear on the LCD screen and you hear a constant beep, the stud sensor has found the center of a stud (Figure D 3 ). NOTE: If live AC voltage is found near the center of a stud, the AC LED will appear on the LCD screen, and the will illuminate, both and stud sensor will sound short alternating beeps (AC found) followed by a longer constant beep (stud center found). , SLOWLY move the stud sensor to the left or . Through the hole on the stud sensor (Figure mark the current position on the wall. F 4 ) use a pencil to • The metal object may be within 3” (76.2mm) to the left or right of the mark. • For the exact position of the metal object, you should refer to building drawings. 8. To find another metal object behind the wall, repeat the same steps. Maintenance • When the stud sensor is not in use, clean the exterior parts with a damp cloth, wipe the stud sensor with a soft dry cloth to make sure it is dry. • Although the stud sensor exterior is solvent resistant, NEVER use solvents to clean the stud sensor. • Store the stud sensor in a clean location at a temperature between -67 ˚F (-55 ˚C) and 158 ˚F (70 ˚C). 9 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 9 5/21/2019 3:39:38 PM E Troubleshooting Service and Repairs The Note: Disassembling the tool will void all warranties on the product. LED is Blinking To assure product SAFETY and RELIABILITY, repairs, maintenance and If the power LED blinks (and the battery level on the LCD screen blinks), adjustment should be performed by authorized service centers. Service the battery power is low. or maintenance performed by unqualified personnel may result in a risk of • Check the AAA batteries to make sure: injury. To locate your nearest DEWALT service center, go to www.DEWALT. com. • Each battery is installed correctly, according to + and – listed inside the battery compartment. • The battery contacts are clean and free of rust or corrosion. • The batteries are new, high-quality batteries to reduce the chance of battery leakage. Warranty Go to www.DEWALT.com for the latest warranty information. • Make sure the AAA batteries are in proper working condition. If in doubt, try installing new batteries. The LED does not Turn On If the power LED does not turn on, or the power sec and then turns off, there is no battery power. LED turns on for 1 • Install two new, high-quality, name-brand AAA batteries in the stud sensor. • Make sure each battery is installed correctly, according to + and – listed inside the battery compartment. The Stud Sensor is not Finding Studs • Make sure the batteries are working. • Make sure you have placed the stud sensor on a wall made of drywall or another common building material. The stud sensor will not work on walls made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced materials, metallic surfaces, or ceramic tile. • Make sure you have placed the stud sensor flat against the wall, the stud sensor is in a vertical position (parallel to a door or window), and you are (Figure A 3 ) as you move the stud sensor pressing and holding SLOWLY against the wall. • Make sure the wall is not too thick. The DW0350 stud sensor can be used to detect wood studs on walls < 1” (25mm) thick or metal studs on walls < 1.5” (38mm) thick. • Make sure the wall has a smooth surface. • Make sure the temperature is within the specified Operating Range and Relative Humidity. The Stud Sensor is not Finding Metal Objects • Make sure the batteries are working. • Make sure you have placed the stud sensor on a wall made of drywall or another common building material. The stud sensor will not work on walls made of concrete, mortar, block, brick work, plaster, carpeting, foil- faced materials, metallic surfaces, or ceramic tile. • Make sure you have placed the stud sensor flat against the wall, the stud sensor is in a vertical position (parallel to a door or window), and you are (Figure A 2 ) as you move the stud sensor pressing and holding SLOWLY against the wall. • Make sure the wall is not too thick. The DW0300 stud sensor can be used to detect Non-Ferrous Metal (e.g., copper) on walls < 2” (51mm) thick or Ferrous Metal (contains iron) on walls < 3” (76.2mm) thick. • Make sure the wall has a smooth surface. • Make sure the temperature is within the specified Operating Range and Relative Humidity. 10 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 10 5/21/2019 3:39:39 PM Specifications E DW0350 Detect Wood Studs up to 1” (25mm) thick drywall Detect Metal Studs up to 1.5” (38mm) thick drywall Detect Live AC Wire 110V @ 60 Hz (220V @ 50Hz) up to 2” (51mm) behind the surface of the wall from a distance of 6”-18” (.15 m- .5 m) AC LED will illuminate Detect Ferrous Metal (contains iron) up to 3” (76.2mm) from the surface of the wall to the center of the metal object (pipe) Detect Non-Ferrous Metal (e.g., copper) up to 2” (51mm) from the surface of the wall to the center of the metal object (pipe) Accuracy - Center of Wood stud +/- 1/4” (6.4mm) under 1/2” to 1” (12.7mm - 25mm) thick drywall Accuracy - Center of Metal stud +/- 1/4” (6.4mm) under 1/2” to 1.5” (12.7mm - 38mm) thick drywall Accuracy - Detecting Metal Objects Power Source Battery Life +/- 3” (76.2mm) 2 AAA (1.5V) size batteries (3V DC) < 10 hrs of continual use at <2.4V (+/- 0.3V), Power LED will flash to indicate low battery Automatic Calibration Yes Automatic Shutoff when release button Yes Non-marring Surface Yes Relative Humidity 35% - 55% Operating Temperature 32°F to 122°F (0°C to 50°C) Storage Temperature -4°F to 150°F (-20°C to 66°C) 11 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 11 5/21/2019 3:39:39 PM Contenido ES • Información de Sensor de Postes • Seguridad de usuario • Seguridad de batería • Instalación de Baterías AAA • Uso del Sensor de Postes • Mantenimiento • Solución de problemas • Servicio y Reparaciones • Garantía • Especificaciones ADVERTENCIA: Si el equipo se utiliza de una manera no especificada por el fabricante, la protección proporcionada por el equipo puede ser deteriorada. Información de Sensor de Postes PRECAUCIÓN: Proteja sus ojos. Use gafas de seguridad. El sensor de postes DW0350 utiliza señales electrónicas para ubicar el centro de los postes de madera o metal, los cables de CA activos, o objetos metálicos (p. ej., tubería) a través de paneles de yeso u otros materiales de construcción comunes. ADVERTENCIA: Esta herramienta no es un dispositivo de medición y no debe usarse como sustituto de un voltímetro. TENGA EN CUENTA: • El sensor de postes no detectará objetos en concreto, mortero, bloques, ladrillos, yeso, alfombras, materiales con revestimiento metálico, superficies metálicas o baldosas de cerámica. ADVERTENCIA: El LED o el símbolo Live Wire Detection en la pantalla es sólo un indicador y en algunas situaciones la opción de detección de voltaje puede no indicar con precisión la presencia de voltaje en una pared en caso de falla interna del dispositivo o funcionamiento incorrecto, y por lo tanto no se debe confiar únicamente para la identificación de la presencia de voltajes peligrosos. También se debe utilizar otra evidencia, como planos de construcción o identificación visual del cableado o puntos de entrada al conducto. • El sensor de perno no detectará tubos de plástico o PVC. Una vez que el centro de un perno de madera o metal, o un objeto metálico se ha detectado en un paso a través de la superficie, el sensor de postes DW0350 enciende los LEDs centrales y suena un tono audible. Un orificio de marcado le permite indicar fácilmente el centro del poste. Seguridad del usuario Siempre siga las prácticas de seguridad adecuadas y use un método de detección separado para verificar una condición de desenergización antes de comenzar a trabajar. Guías de Seguridad Las siguientes definiciones describen el nivel de severidad para cada palabra de señal. Por favor lea el manual y ponga atención a estos símbolos. ADVERTENCIA: Siempre apague la energía CA cuando trabaje cerca del cableado.   ADVERTENCIA: Indica una situación potencialmente peligrosa que, si no se evita, podría resultar en lesiones serias. PRECAUCIÓN: Indica una situación potencialmente peligrosa que, si no se evita, puede resultar en lesiones menores o moderadas. ADVERTENCIA: Es posible que no se detecten cables o cables blindados en los conductos metálicos, carcazas, paredes metalizadas o paredes gruesas y densas. AVISO: Indica una práctica no relacionada con lesiones personales que, si no se evita, puede resultar en daño a la propiedad. PRECAUCIÓN: Use equipo de protección personal. Siempre use protección para los ojos. Dependiendo de las condiciones de trabajo, usar equipo de protección tal como una máscara de polvo, zapatos de seguridad anti-deslizantes, casco, y protección auditiva reducirá el riesgo de lesiones personales. Si tiene cualquier pregunta o comentario sobre esta o cualquier herramienta DEWALT®, visite www.DEWALT.com. ADVERTENCIA: Lea y entienda todas las instrucciones. La falla en seguir las advertencias e instrucciones en este manual puede resultar en lesiones personales serias. CONSERVE ESTAS INSTRUCCIONES AVISO DE SEGURIDAD IMPORTANTE Asegure la detección adecuada de cables activos. Siempre sostenga el sensor de postes DW0350 únicamente en el área de la manija. Sujete entre los dedos y el pulgar mientras hace contacto con la palma (Figura C 1 ). ADVERTENCIA: La información de la etiqueta siguiente se puede encontrar en su herramienta para su seguridad. 12 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 12 5/21/2019 3:39:40 PM Declaración de conformidad del proveedor 47 CFR § 2,1077 información de cumplimiento Identificador único: DW0350 Parte responsable – información de contacto de Estados Unidos DEWALT 701 East Joppa Road Towson, Maryland 21286 www.DEWALT.com 4. Seguridad de la Batería ADVERTENCIA: Las baterías pueden explotar, o tener fugas, y pueden causar lesiones personales o incendios. Para reducir este riesgo: • Siga todas las instrucciones y advertencias colocadas en las etiquetas y el paquete de las baterías. • S  iempre inserte las baterías correctamente respecto a la polaridad (+ y –), como está marcado en la batería y el equipo. • No ponga en corto las terminales de la batería. • No cargue las baterías desechables. • No mezcle baterías nuevas y viejas. Cambie todas las baterías al mismo tiempo con baterías nuevas del mismo tipo y marca. • Retire las baterías descargadas de inmediato y deséchelas conforme a los códigos locales. B 4 ). • Inserte las dos clavijas en la parte superior de la cubierta en los orificios cerca de la parte superior del compartimento de la batería. • Baje lentamente la tapa y presione hacia abajo hasta que el seguro se bloquee firmemente en el sensor de postes. 5. Presione o para probar el sensor de postes. o , el LED de energía verde • Siempre que presione se debe iluminar para indicar que las baterías están en buenas condiciones. Si este LED parpadea o no se ilumina, cambie las baterías. Cuando la herramienta esté ENCENDIDA, el nivel de batería aparece en la pantalla (Figura A 7 ). Uso del Sensor de Postes El sensor de postes lo ayudará a encontrar postes de madera o metal, voltaje CA, o objetos metálicos (p. ej., tubería) detrás de paneles de yeso. • El sensor de postes tiene dos botones. Utilice el botón inferior (Figura A 3 ) para buscar postes de madera/metal o AC, y utilice el botón superior (Figura A 2 ) para buscar objetos metálicos (p. ej., tubería). • El sensor de postes detectará postes de madera a través de paneles de yeso de hasta 1” (25mm) de grosor, y postes de metal y voltaje de CA a través de hasta 1,5” (38mm) de espesor de yeso. • El sensor de postes detectará un objeto de metal ferroso (contiene hierro) de hasta 3 “(76,2 mm) desde la superficie de la pared hasta el centro del objeto. • El sensor de postes detectará un objeto metálico no ferroso (p. ej., cobre) hasta 2 “(51mm) desde la superficie de la pared hasta el centro del objeto. • Cuando se encuentre voltaje CA, el sensor de postes emitirá un pitido corto (alternando) y encenderá el LED de CA (Figura A 5 ) y mostrar el icono de CA en la pantalla LCD (Figura A 4 ). • Cuando se encuentra el centro de postes (o un objeto metálico está cerca), el sensor de postes proporciona un sonido más largo (constante) en la pantalla LCD (Figure A 4 ). y mostrar las flechas centrales • Cuando se encuentran tanto CA activo como el centro de un poste, el sensor de postes se alternará entre los pitidos largos y cortos, mostrar y en la pantalla LCD, y encenderá el LED de CA. • No deseche las baterías en fuego. Encontrar un Poste • Mantenga las baterías fuera del alcance de los niños. 1. Para sostener el sensor de postes, coloque el pulgar en un lado del sensor de postes, el dedo índice y la palma sobre el centro del sensor de postes, y el resto de los dedos en la misma mano en el otro lado del sensor de postes (Figura C 1 ). 2. Coloque suavemente el sensor de postes plano contra la pared y paralelo a una puerta o ventana en la misma pared, lo que le dará una indicación de cómo los postes están ubicados detrás de la pared (Figura C 2 ). 3. Sin mover el sensor de postes, use el dedo índice para mantener presionado (Figura A 3 ). ESPERE 1 segundo hasta que todos los LEDs (excepto el LED de encendido ) se apagarán y todos los iconos de la pantalla LCD se apagan excepto el nivel de batería. 4. Mientras sigue presionando , mueva LENTAMENTE el sensor de postes hacia la izquierda o hacia la derecha en la pared. Instalación de Baterías AAA Cargue dos baterías AAA nuevas en el sensor de postes DW0350. 1. En la parte inferior del detector de estructuras, levante el enganche (Figura B 1 ) para abrir la tapa del compartimento de las pilas. 2. Mueva la cubierta hacia arriba (Figura separe del sensor de postes. 3. Inserte dos nuevas baterías AAA de alta calidad, asegurándose de colocar los extremos - y + de cada batería como se indica en el interior del compartimiento de baterías (Figura B 3 ). B 2 ES • El sensor de postes emitirá un pitido corto. El LED de encendido y el icono de la batería en la pantalla LCD debe encendearlo. El LED de CA y todos los demás iconos de la pantalla LCD deben iluminarse por un segundo y luego apagarlo. Declaración de FCC Este equipo ha sido probado y cumple con los límites para dispositivos digitales de clase B, de conformidad con la parte 15 de las normas FCC. Estos límites han sido diseñados para proporcionar una protección razonable contra las interferencias nocivas en instalaciones residenciales. Este equipo genera, usa e irradia energía de radiofrecuencia y, si no se instala y se usa de acuerdo con las instrucciones, puede causar interferencia perjudicial para las radiocomunicaciones. No obstante, no existe ninguna garantía de que no se producirá interferencia en una instalación determinada. Si este equipo causa interferencias perjudiciales para la recepción de radio o televisión, que puede determinarse al encender y apagar el equipo, el usuario puede tratar de corregir la interferencia tomando una o varias de las siguientes medidas: - Reorientar o reubicar la antena receptora. - Aumentar la distancia entre el equipo y el receptor. - Conectar el equipo en un tomacoriente de otro circuito diferente (no el circuito al que está conectado el receptor). - Consulte al vendedor o a un técnico experto en radio/TV para solicitar su ayuda. Coloque la cubierta de nuevo en el sensor de postes (Figura ) y retírela una vez que se 13 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 13 5/21/2019 3:39:41 PM A medida que mueve el sensor de postes, observe las flechas mostradas en la pantalla LCD y escuche los sonidos. 5. aparecen en lado derecho la pantalla • Si las flechas lejanos LCD (Figura D 1 ), continuar moviendo el sensor a la derecho para encontrar el poste más cercano. A medida que te acerques el poste, se aparece (Figura D 2 ). ES 4. Mientras sigue presionando , mueva LENTAMENTE el sensor de postes hacia la izquierda o hacia la derecha en la pared. 5. A medida que mueve el sensor de postes, observe las flechas mostradas en la pantalla LCD. y aparezca en la pantalla LCD, mueva • Cuando LENTAMENTE el sensor a la derecho o izquierda para encontrar el objeto del metal (Figura F 1 ). aparecen en lado izquierdo la pantalla • Si las flechas lejanos LCD, continuar moviendo el sensor de postes a la izquierdo para encontrar el poste más cercano. A medida que te acerques el poste, se aparece. • Si se encuentra CA activo dentro de 6”-18” (.15m - .5m) de la posición actual del sensor de postes, el LED de CA (Figura A 5 ) se iluminará, aparecen en la pantalla LCD y escuchará sonidos cortos. NOTA: Las cargas eléctricas estáticas que pueden desarrollarse en los paneles de yeso y otras superficies extenderán el área de detección de voltaje varias pulgadas a cada lado del cable eléctrico real. Esto puede causar que el sensor de postes indique que ha encontrado el AC vivo cuando no está realmente cerca de un cable eléctrico (Figura E 1 ). Para ayudar a ubicar la posición del cable, coloque la otra mano sobre la superficie a aproximadamente a 12” (30cm) del sensor (Figura E 2 ) o escanee sosteniendo la unidad a ½” - 2” (13mm - 50mm) de distancia de la superficie de la pared.. Cuando las flechas central se aparezcan en la pantalla LCD y escucha un sonido constante, el sensor de postes encontró el centro de un poste (Figura D 3 ). 6. y aparezca en la pantalla LCD, usted sabrá • Cuando que está moviendo el sensor más cerca del objeto metálico (Figura F 2 ). 6. Cuando las flechas central se aparezcan en la pantalla LCD y escucha un sonido constante, el sensor encontró un objeto metálico dentro de 3 “(76,2 mm) a la izquierda o a la derecha de la posición actual (Figura F 3 ). • DEJE de mover el sensor de postes y continúe sujetándolo en la posición actual. • DEJE de presionar 7. . A través del orificio en el sensor de postes (Figura para marcar la posición actual. F 4 ), use un lápiz • El objeto metálico puede estar dentro de 3 “(76,2 mm) a la izquierda o a la derecha de la marca. • Para la posición exacta del objeto metálico, debe referirse a los dibujos de construcción. 8. Para encontrar otro objeto del metal, repita los mismos pasos. NOTA: Si se encuentra voltaje de CA activo cerca del centro de un aparecen en la pantalla poste, el LED de CA se iluminarán, y LCD y el sensor de postes emitirá un sonido corto alterno (CA • Cuando el sensor de postes no esté en uso, limpie las partes exteriores encontrado) seguido de un sonido constante más largo (centro de perno con un paño húmedo, limpie el sensor de postes con un paño suave encontrado). y seco para asegurarse que esté seco. • DEJE de mover el sensor de postes y continúe sujetándolo en la • Aunque el exterior del sensor de postes es resistente a los solventes, posición actual. NUNCA use solventes para limpiar el sensor de postes. . • DEJE de presionar • Guarde el sensor de postes en un lugar limpio a una temperatura entre A través del orificio en el sensor de postes (Figura D 4 ), use un lápiz -67 ˚F (-55 ˚C) y 158 ˚F (70 ˚C). para marcar la posición actual como el centro del poste. Mantenimiento 7. 8. Para encontrar otro poste en la pared, repita los mismos pasos. Encontrar de Objetos Metálicos El sensor de postes le permitirá saber si un objeto metálico (p. ej., una tubería) se encuentra detrás de la pared a menos de 3” (76.2mm) del sensor de postes. En el modo de detección de metales, las flechas no indican en qué dirección mover el sensor de postes para encontrar metal. 1. 2. 3. Para sostener el sensor de postes, coloque el pulgar en un lado del sensor de postes, el dedo índice y la palma sobre el centro del sensor de postes, y el resto de los dedos en la misma mano en el otro lado del sensor de postes (Figura C 1 ). Coloque suavemente el sensor de postes plano contra la pared y paralelo a una puerta o ventana en la misma pared, lo que le dará una indicación de cómo los postes están ubicados detrás de la pared (Figura C 2 ). Solución de Problemas El LED parpadea Si el LED de energía verde parpadea (y parpadea el nivel de batería en la pantalla LCD), la energía de la batería es baja. • Verifique las baterías AAA para asegurarse que: • Cada batería esté instalada correctamente, de acuerdo con + y enumerados dentro del compartimento de la batería. • Los contactos de la batería están limpios y libres de óxido o corrosión. • Las baterías son baterías nuevas de alta calidad para reducir la posibilidad de fugas de la batería. • Asegúrese que las baterías AAA estén en buenas condiciones de operación. En caso de duda, intente instalar baterías nuevas. El LED no enciende Si el LED no se enciende, o el LED se enciende durante 1 s y luego se apaga, no hay energía de la batería. Sin mover el sensor de postes, use el dedo índice para mantener presionado (Figura A 2 ). Después de 1 segundo todos los LEDs • Instale dos nuevas pilas AAA de alta calidad en el sensor de postes. (excepto el LED de encendido ) se apagarán y todos los iconos de la • Asegúrese que cada batería esté instalada correctamente, de acuerdo pantalla LCD se apagan excepto el nivel de batería y . con + y - indicados dentro del compartimento de la batería. 14 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 14 5/21/2019 3:39:42 PM El sensor de postes no encuentra postes • Asegúrese que las baterías estén en buenas condiciones. • Asegúrese de haber colocado el sensor de postes en una pared hecha de paneles de yeso u otro material de construcción común. El sensor de postes no funcionará en paredes hechas de concreto, mortero, bloques, ladrillos, yeso, alfombras, materiales con revestimiento metálico, superficies metálicas o baldosas de cerámica. ES • Asegúrese de haber colocado el sensor de postes plano contra la pared, el sensor de espárrago está en una posición vertical (paralela a una puerta o ventana), y está presionando y manteniendo presionado (Figura A 3 ) mientras mueve el sensor de postes LENTAMENTE contra la pared. • Asegúrese que la pared no sea demasiado gruesa. El sensor de postes DW0350 se puede usar en paredes < 2” (51mm) de espesor. El sensor de postes detectará postes de madera a través de paneles de yeso de hasta 1” (25mm) de grosor, y postes de metal a través de hasta 1,5” (38mm) de espesor de yeso. • Asegúrese que la pared tenga una superficie lisa. • Asegúrese que la temperatura esté dentro del Rango de operación y Humedad relativa especificados. El sensor de postes no encuentra Objetos Metálicos • Asegúrese que las baterías estén en buenas condiciones. • Asegúrese de haber colocado el sensor de postes en una pared hecha de paneles de yeso u otro material de construcción común. El sensor de postes no funcionará en paredes hechas de concreto, mortero, bloques, ladrillos, yeso, alfombras, materiales con revestimiento metálico, superficies metálicas o baldosas de cerámica. • Asegúrese de haber colocado el sensor de postes plano contra la pared, el sensor de espárrago está en una posición vertical (paralela a una puerta o ventana), y está presionando y manteniendo presionado (Figura A 2 ) mientras mueve el sensor de postes LENTAMENTE contra la pared. • Asegúrese que la pared no sea demasiado gruesa. El sensor de postes DW0300 detectará metales no ferrosos (p. ej., cobre) a través de hasta 2” (51mm) y metales ferrosos (contiene hierro) hasta 3” (76.2mm) de grosor. • Asegúrese que la pared tenga una superficie lisa. • Asegúrese que la temperatura esté dentro del Rango de operación y Humedad relativa especificados. Servicio y Reparaciones Nota: Desensamblar la herramienta anulará todas las garantías del producto. Para garantizar la SEGURIDAD y CONFIABILIDAD del producto, las reparaciones, el mantenimiento y el ajuste deben ser realizados por centros de servicio autorizados. El servicio o mantenimiento realizado por personal no calificado puede ocasionar lesiones. Para localizar a su centro de servicio DEWALT más cercano, visite www.DEWALT.com. Garantía Vaya a www.DEWALT.com para obter informações sobre garantia. 15 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 15 5/21/2019 3:39:42 PM Especificaciones DW0350 ES Detectar postes de madera panel de yeso de hasta 1” (25mm) Detectar postes de metal Detectar cable de CA activo 110V @ 60 Hz (220V @ 50Hz) panel de yeso de hasta 1.5” (38mm) hasta 2” (51mm) detrás de la superficie de la pared desde una distancia de 6”-18” (0.15 m - 0.5 m) se iluminará el LED de CA Detectar metales ferrosos (contiene hierro) hasta 3” (76.2mm) desde la superficie de la pared hasta el centro del objeto metálico (tubería) Detectar metales no ferrosos (p. ej., cobre) hasta 2” (51mm) desde la superficie de la pared hasta el centro del objeto metálico (tubería) Precisión - Centro de Poste de madera +/- 1/4” (6.4mm) bajo panel de yeso de 1/2” - 1” (12.7mm - 25mm) de espesor Precisión - Centro de Poste de metal +/- 1/4” (6.4mm) debajo de panel de yeso de 1/2” - 1.5” (12.7mm - 38mm) de espesor Precisión - Detectar objetos metálicos +/- 3” (76.2mm) Fuente de energía Vida de batería 2 baterías tamaño AAA (1.5V) (3V CD) el < 10 hrs de uso continuo en <2.4V (+/- 0.3V), LED de Energía parpadeará para indicar batería baja Calibración automática Sí Apagado automático cuando se libera el botón de encendido Sí Superficie de protección Humedad relativa Sí 35% - 55% Temperatura de operación 32°F a 122°F (0°C a 50°C) Temperatura de almacenamiento -4°F a 150°F (-20°C a 66°C) 16 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 16 5/21/2019 3:39:42 PM Table des matières • Renseignements sur le détecteur de montants • Sécurité de l'utilisateur • Sécurité concernant les piles • Installer des piles AAA • Utiliser le détecteur de montants • Entretien • Dépannage • Réparations • Garantie • Caractéristiques Renseignements sur le Détecteur de Montants ATTENTION : Protégez vos yeux. Portez des lunettes de sécurité. Le détecteur de montants DW0350 utilise des signaux électroniques pour localiser le centre des montants en bois ou en métal, les fils sous tension, ou des objets métalliques (p. ex. tuyau) à travers la cloison sèche. AVERTISSEMENT : Cet outil n’est pas un instrument de mesure et ne doit pas être utilisé pour remplacer un voltmètre. VEUILLEZ NOTER : • Le détecteur de montants ne détectera pas les objets dans le béton, le mortier, la roche, le briquetage, le plâtre, le tapis, les matériaux à base de feuilles d’aluminium, les surfaces métalliques ou les carreaux de céramique. AVERTISSEMENT : Le voyant DEL ou le symbole détection de fils sous tension sur l’affichage est simplement un indicateur et, dans certaines situations, l’option de détection de la tension peut ne pas indiquer avec précision la présence de la tension dans un mur en cas de défaillance interne de l’appareil ou d’une mauvaise utilisation et, par conséquent, ne doit pas être seulement utilisée pour l’identification de la présence de tensions dangereuses. D'autres éléments, comme les plans de construction ou l’identification visuelle des points d’entrée des fils ou des conduits, doivent aussi être utilisés. • Le détecteur de montants ne détecte pas les tuyaux en plastique ou en PVC. Une fois que le centre d’un goujon en bois ou en métal, ou un objet en métal a été détecté dans un passage à travers la surface, le goujon Sensor DW0350 allume les LEDs du centre et sonne une tonalité audible. Un trou de repérage vous permet d’indiquer facilement le centre du montant. Sécurité de l'utilisateur Appliquez toujours les pratiques de sécurité appropriées et utilisez une méthode de détection séparée pour vous assurer qu’il n’y a pas de tension avant de commencer à travailler. Directives sur la sécurité Les définitions suivantes décrivent le niveau de sévérité pour chaque motindicateur. Veuillez lire le manuel et porter attention à ces symboles. AVERTISSEMENT : Coupez toujours l’alimentation CA lorsque vous travaillez près des fils.   AVERTISSEMENT : Indique une situation potentiellement dangereuse qui, si elle ne peut être évitée, pourrait entraîner des blessures graves. AVERTISSEMENT : Les fils blindés ou des fils dans des conduits métalliques, les boîtiers, les murs métallisés ou les murs denses et épais peuvent ne pas être détectés. ATTENTION : Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, peut entraîner une blessure légère ou modérée. ATTENTION : Utilisez un équipement de protection individuel. Portez toujours une protection oculaire. Selon les conditions de travail, porter un équipement de protection comme un masque antipoussières, des chaussures de sécurité antidérapantes, un casque de sécurité et une protection auditive réduira le risque de blessure corporelle. AVIS : Indique une pratique non liée à une blessure corporelle qui, si elle n’est pas évitée, peut entraîner des dommages matériels. Si vous avez des questions ou des commentaires sur cet outil ou tout autre outil DEWALT®, visitez le www.DEWALT.com. AVERTISSEMENT : Lisez et comprenez toutes les instructions. Ne pas suivre les avertissements et les instructions de ce manuel peut entraîner une blessure corporelle grave. F AVERTISSEMENT : Si l’équipement est utilisé d’une manière non spécifiée par le fabricant, la protection fournie par l’équipement peut être altérée. AVIS IMPORTANT DE SÉCURITÉ Assurez-vous de bien détecter les fils sous tension. Tenez toujours le détecteur de montants DW0350 seulement par la poignée. Saisissez-la entre vos doigts et votre pouce tout en effectuant un contact avec votre paume (Figure C 1 ). CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT : Les informations suivantes sur l’étiquette peuvent être trouvées sur votre outil pour votre sécurité. 17 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 17 5/21/2019 3:39:43 PM Déclaration de conformité du fournisseur 47 CFR § 2,1077 informations de conformité Identificateur unique: DW0350 Partie responsable – coordonnées des États-Unis DEWALT 701 East Joppa Road Towson, Maryland 21286 www.DEWALT.com F Déclaration de la FCC Cet équipement a été testé et il est conforme aux limites de la classe B des équipements numériques, conformément à la partie 15 de la réglementation de la FCC. Ces limites sont prévues pour offrir une protection raisonnable contre le brouillage préjudiciable dans une installation résidentielle. Cet équipement génère, utilise, peut émettre de l’énergie de fréquence radio et, s’il n’est pas installé ou utilisé conformément aux instructions, peut entraîner un brouillage préjudiciable aux communications radio. Cependant, il n’y a pas de garantie que ce brouillage se produira dans une installation particulière. Si cet équipement cause du brouillage préjudiciable à la réception de la radio ou de la télévision, qui peut être déterminé en allumant et éteignant l’équipement, l’utilisateur est incité à corriger le brouillage par une ou plusieurs de mesures suivantes : - Réorientez ou déplacez l’antenne réceptrice. - Augmentez l’espace séparant l’équipement du récepteur. - Branchez l’équipement dans une prise de courant faisant partie d’un circuit différent (autre que celui auquel le récepteur est branché). - Consultez le détaillant ou un technicien en radio/télévision pour obtenir de l’aide. • Retirez immédiatement les piles à plat et éliminez-les selon les codes locaux. • Ne pas jeter les piles au feu. • Gardez les piles hors de portée des enfants. Installer des Piles AAA Insérez deux nouvelles piles AAA dans le détecteur de montants DW0350. 1. Au bas du détecteur, soulevez l’attache (Figure déverrouiller le cache du compartiment à piles. 2. Levez le couvercle (Figure détecteur de montants. 3. Insérez deux nouvelles piles AAA de haute qualité, en vous assurant de placer les extrémités - et + de chaque pile comme indiqué à l'intérieur du compartiment des piles (Figure B 3 ). 4. Remettez le couvercle sur le détecteur de montants (Figure Conformément à la réglementation d’Innovation, Sciences et Développement économique Canada, le transmetteur radio de cet appareil peut seulement fonctionner à l’aide d’une antenne du type et du gain maximum (ou moins) approuvé pour les transmetteurs par Innovation, Sciences et Développement économique Canada. Afin de réduire les interférences radio potentielles aux autres utilisateurs, le type de l’antenne et son gain doivent être choisis pour que la puissance isotrope rayonnée équivalente ne dépasse pas le minimum nécessaire à une bonne communication. Sécurité Concernant les Piles AVERTISSEMENT : Les piles peuvent exploser ou fuir et causer une blessure ou un incendie. Afin de réduire ce risque: • Suivez attentivement toutes les instructions et les avertissements des étiquettes apposées sur les piles et leur emballage. • Insérez toujours les piles correctement en ce qui concerne la polarité (+ et –), comme indiqué sur la pile et l’équipement. ) pour )et retirez-le dès qu’il se sépare du B 4 ). • Insérez les deux tiges en haut du couvercle dans les trous dans vers le haut du compartiment à piles. • Baissez lentement le couvercle et appuyez vers le bas jusqu’à ce qu’il se verrouille de façon sécuritaire sur le détecteur de montants. 5. Appuyez sur ou pour tester le détecteur de montants. • Le détecteur de montants émet un bip court. Le voyant d’alimentation et l’icône de batterie sur l’écran LCD doit s’allumer. La LED AC et toutes les autres icônes sur l’écran LCD doivent s’allumer pendant une seconde puis s’éteindre. ou , le voyant • Chaque fois que vous appuyez sur d’alimentation vert DEL doit s’allumer pour indiquer que les piles sont bonnes. Si ce voyant DEL clignote ou ne s’allume pas, changez les piles. Lorsque l’outil est allumé, le niveau de charge de la pile apparaît dans la fenêtre d’affichage (Figure A 7 ). Canada, Avis d’Innovation, Sciences et Développement économique Canada (ISDE) Cet équipement est conforme à la (aux) norme(s) RSS d’Innovation, Sciences et Développement économique Canada exempte(s) de licence. Son fonctionnement est assujetti aux deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d’interférences, et (2) cet appareil doit accepter les interférences reçues, dont celles pouvant provoquer un fonctionnement indésirable de l’appareil. B 2 B 1 Utiliser le Détecteur de Montants Le détecteur de montants vous aidera à trouver les montants en bois ou en métal, une tension C.A. ou des objets métalliques (par exemple, un tuyau) derrière la cloison sèche. • Le détecteur de montants tiene dos botones. Utilice el botón inferior (Figure A 3 ) para buscar postes de madera/metal o AC, y utilice el botón superior (Figure A 2 ) para buscar objetos metálicos (p. ej., tubería). • Le détecteur de montants détectera les goujons en bois jusqu’à une cloison sèche épaisse de 1 “(25mm), et les goujons en métal et la tension C.A. jusqu’à 1,5” (38mm) cloison sèche épaisse. • Le détecteur de montants détectera un objet en métal ferreux (contient du fer) jusqu’à 3 “(76,2 mm) de la surface du mur au centre de l’objet. • Le détecteur de montants détectera un objet métallique non ferreux (par exemple, le cuivre) jusqu’à 2 “(51mm) de la surface du mur au centre de l’objet. • Lorsque la tension alternative est trouvée, le détecteur de montants émet un bip court (alternant) et allume la LED AC (Figure A 5 ) et afficher l’icône AC sur l’écran LCD (Figure A 4 ). • Ne pas recharger les piles jetables. • Lorsque le centre d’un goujon est trouvé (ou un objet métallique est à proximité), le détecteur de montants émet un bip plus long (constant) et sur l’écran LCD (Figure A 4 ) afficher les flèches du centre • Ne pas mélanger d’anciennes piles avec des nouvelles. Remplacez toutes les piles par des piles neuves de même marque et de même type, en même temps. • Lorsque l’alimentation et le centre du montant sont trouvés, le détecteur sur de montants alterne entre les bips longs et courts, afficher et l’écran LCD, et il allume le voyant du AC. • Ne pas court-circuiter les bornes des piles. 18 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 18 5/21/2019 3:39:44 PM Trouver un Montant Recherche d’objets Métalliques 1. Pour tenir le détecteur de montants, placez votre pouce sur un côté du détecteur de montants, votre index et votre paume au-dessus du centre du détecteur de montants et le reste de vos doigts de la même main de l'autre côté du détecteur de montants (Figure C 1 ). 2. Placez doucement le détecteur de montants à plat contre le mur et parallèle à une forte ou une fenêtre sur le même mur, ce qui vous donne une idée de la façon dont les montants sont placés derrière le mur (Figure C 2 ). 3. Sans déplacer le détecteur de montants, utilisez votre index pour appuyer et maintenir (Figure A 3 ). ATTENDRE 1 seconde jusqu’à ce que toutes les LEDs (sauf la LED Power ) s’éteignent et toutes les icônes sur l’écran LCD s’éteins sauf le niveau de la batterie. 4. Pendant que vous appuyez encore , déplacez LENTEMENT le détecteur de montants vers la gauche ou la droite sur le mur. 5. Lorsque vous déplacez le détecteur, observez les flèches affichées sur l’écran LCD et écoutez les bips. apparaissent sur le côté droit de l’écran • Si les flèches distantes LCD (Figure D 1 ), continuez à déplacer le détecteur de montants vers la droit pour trouver le montant le plus près. Lorsque vous approchez du montant, apparaît sur l’écran LCD (Figure D 2 ). Le détecteur de montants vous permettra de savoir si un objet métallique (par exemple, un tuyau) est situé derrière le mur à moins de 3” (76.2mm) du cdétecteur de montants. En mode de détection des métaux, les flèches n’indiquent pas quelle direction déplacer le détecteur de montants pour trouver le métal. 1. 2. Placez doucement le détecteur de montants à plat contre le mur et parallèle à une forte ou une fenêtre sur le même mur, ce qui vous donne une idée de la façon dont les montants sont placés derrière le mur (Figure C 2 ). 3. Sans déplacer le détecteur de montants, utilisez votre index pour appuyer et maintenir (Figure A 2 ). Après 1 seconde, toutes les LEDs (sauf la LED Power ) s’éteignent et toutes les icônes sur . l’écran LCD s’éteins sauf le niveau de la batterie et 4. Pendant que vous appuyez encore , déplacez LENTEMENT le détecteur de montants vers la gauche ou la droite sur le mur. 5. Lorsque vous déplacez le détecteur de montants, observez les flèches affichées sur l’écran LCD. apparaissent sur le côté gauche de • Si les flèches distantes l’écran LCD, continuez à déplacer le détecteur de montants vers la gauche pour trouver le montant le plus près. Lorsque vous approchez du montant, apparaît sur l’écran LCD. • Si la tension alternative est trouvée à l’intérieur de 6 à 18 po (0,15 m à 0,5 m) de la position actuelle du détecteur de montants, le voyant DEL de courant alternatif (Figure A 5 ) s’allumera, apparaissent de l’écran LCD et vous entendrez bips. REMARQUE : Des charges d’électricité statique qui peuvent se développer sur la cloison sèche et d’autres surfaces étendront la zone de détection de la tension de plusieurs pouces de chaque côté du fil électrique actuel. Cela peut provoquer le capteur de goujon pour indiquer qu’il a trouvé l’AC en direct quand il n’est pas en fait près d’un fil électrique (Figure E 1 ). Pour aider à localiser la position des fils, placez votre autre main sur la surface à environ 12 po (30cm) du détecteur (Figure E 2 ) ou balayez en tenant l’unité à ½ po - 2 po (13mm - 50mm) de la surface du mur. 6. • ARRÊTEZ de déplacer le détecteur de montants et continuez à le maintenir à la position actuelle. • ARRÊTEZ d’appuyer sur . 7. Par le trou du détecteur de montants (Figure D 4 ), utilisez un crayon pour indiquer la position actuelle comme le centre du montant. 8. Pour trouver un autre montant sur le mur, répétez les mêmes étapes. F et apparaissent sur l’écran LCD, déplacez lentement • Quand le détecteur vers la droite ou vers la gauche pour trouver l’objet métallique le plus proche (Figure F 1 ). et apparaissent sur l’écran LCD, vous saurez • Quand que vous déplacez le capteur plus près de l’objet métallique (Figure F 2 ). 6. Lorsque les flèches du centre apparaissent sur l’écran LCD et que vous entendez un bip constant, le détecteur a trouvé un objet métallique à moins de 76,2 mm (3 “) à gauche ou à droite de la position actuelle (Figure F 3 ). • ARRÊTEZ de déplacer le détecteur et continuez à le maintenir à la position actuelle. • ARRÊTEZ d’appuyer sur 7. . Par le trou du détecteur de montants (Figure pour indiquer la position actuelle. F 4 ), utilisez un crayon • L’objet métallique peut être à moins de 3 “(76,2 mm) à gauche ou à droite de la marque. Lorsque les flèches du centre apparaissent sur l’écran LCD et que vous entendez un bip constant, le détecteur de montants a trouvé le centre d’un montant (Figure D 3 ). REMARQUE :Si la tension alternative est trouvée près du centre d’un montant, le voyant DEL de courant alternatif s’allume, et apparaît sur l’écran LCD, et le détecteur de montants émettra bips en alternance (courant alternatif trouvé) suivis d’un bip constant plus long (centre d’un montant trouvé. Pour tenir le détecteur de montants, placez votre pouce sur un côté du détecteur de montants, votre index et votre paume au-dessus du centre du détecteur de montants et le reste de vos doigts de la même main de l’autre côté du détecteur de montants (Figure C 1 ). • Pour la position exacte de l’objet métallique, vous devez vous référer aux dessins de construction. 8. Pour trouver un autre objet métallique, répétez les mêmes étapes. Entretien • Lorsque le détecteur de montants n’est pas utilisé, nettoyez les pièces extérieures avec un linge humide, essuyez-le avec un linge sec doux pour vous assurer qu’il est sec. • Même si l’extérieur du détecteur de montants est résistant aux solvants, NE JAMAIS utiliser de solvants pour nettoyer le détecteur de montants. • Entreposez le détecteur de montants dans un endroit propre à une température entre -55 ˚C (-67 ˚F) et 70 ˚C (158 ˚F). 19 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 19 5/21/2019 3:39:44 PM Dépannage Le voyant DEL clignote Si le voyant DEL clignote (et que le niveau de la batterie clignote sur l’écran LCD), la pile est faible. F • Vérifiez les piles AAA pour vous assurer que : • Chaque pile est installée correctement, selon + et – indiqués à l’intérieur du compartiment des piles. • Les contacts des piles sont propres et sans rouille ou corrosion. • Ce sont de nouvelles piles de haute qualité afin de réduire le risque de fuite des piles. • Assurez-vous que les piles AAA fonctionnent bien. En cas de doute, essayer d’installer de nouvelles piles. Le voyant DEL ne s'allume pas Si la LED ne s’allume pas, ou si la LED s’allume pendant 1 s, puis s’éteint, il n’y a pas d’alimentation de la pile. • Installez deux nouvelles piles AAA de marque et de haute qualité dans le détecteur. • Assurez-vous que le mur n’est pas trop épais. Le détecteur de montants détectera Non-Ferrous Metal (p. ex., cuivre) jusqu’à 2 po (51mm), et les le métal ferreux (contient du fer) jusqu’à 3 po (76.2mm) cloison sèche épaisse. • Assurez-vous que le mur a une surface lisse. • Assurez-vous que la température respecte la plage de fonctionnement et l’humidité relative indiquées. Réparations Remarque : Désassembler l’outil annulera toute garantie sur le produit. Pour assurer la SÉCURITÉ et la FIABILITÉ du produit, les réparations, l’entretien et l’ajustement doivent être effectués par des centres de services autorisés. Les réparations ou l’entretien effectué par du personnel non qualifié peuvent entraîner un risque de blessure. Pour localiser le centre de service DEWALT le plus près, consultez www.DEWALT.com. Garantie Allez à www.DEWALT.com pour obtenir des informations sur la garantie. • Assurez-vous que chaque pile est installée correctement, selon + et – indiqués à l’intérieur du compartiment des piles. Le détecteur de montants ne trouve pas de montants • Assurez-vous que les piles fonctionnent. • Assurez-vous que vous avez placé le détecteur de montants sur un mur fait d’une cloison sèche ou un autre matériau de construction courant. Le détecteur de montants ne fonctionnera pas sur les murs faits de béton, mortier, roche, briquetage, plâtre, tapis, matériaux à base de feuilles d’aluminium, surfaces métalliques ou carreaux de céramique. • Assurez-vous que vous avez placé le détecteur de montants à plat contre le mur, le détecteur de montants est en position verticale (parallèle à une porte ou une fenêtre) et que vous avez appuyé et maintenu (Figure A 3 ) pendant que vous déplacez LENTEMENT le détecteur de montants contre le mur. • Assurez-vous que le mur n’est pas trop épais. Le détecteur de montants détectera les goujons en bois jusqu’à une cloison sèche épaisse de 1” (25mm), et les goujons en métal et la tension C.A. jusqu’à 1,5” (38mm) cloison sèche épaisse. • Assurez-vous que le mur a une surface lisse. • Assurez-vous que la température respecte la plage de fonctionnement et l’humidité relative indiquées. Le détecteur de montants ne trouve pas d’objets Métalliques • Assurez-vous que les piles fonctionnent. • Assurez-vous que vous avez placé le détecteur de montants sur un mur fait d’une cloison sèche ou un autre matériau de construction courant. Le détecteur de montants ne fonctionnera pas sur les murs faits de béton, mortier, roche, briquetage, plâtre, tapis, matériaux à base de feuilles d’aluminium, surfaces métalliques ou carreaux de céramique. • Assurez-vous que vous avez placé le détecteur de montants à plat contre le mur, le détecteur de montants est en position verticale (parallèle à une porte ou une fenêtre) et que vous avez appuyé et maintenu (Figure A 2 ) pendant que vous déplacez LENTEMENT le détecteur de montants contre le mur. 20 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 20 5/21/2019 3:39:45 PM Caractéristiques DW0350 Détecter les montants en bois cloison sèche d’une épaisseur allant jusqu’à 1 po (25 mm) Détecter les montants en métal cloison sèche d’une épaisseur allant jusqu’à 1,5 po (38 mm) Détecter les fils de courant alternatif 110 V @ 60 Hz (220 V @ 50 Hz) jusqu’à 2 po (50,8 mm) derrière la surface du mur d’une distance de 6 à 18 po (0,15 à 0,5 m) le voyant de courant alternatif s’allumera Détecter le métal ferreux (contient du fer) jusqu’à 3 po (76.2mm) derrière la surface du mur au centre de l’objet métallique (tuyau) Detect Non-Ferrous Metal (p. ex., cuivre) jusqu’à 2 po (51mm) derrière la surface du mur au centre de l’objet métallique (tuyau) F Précision - Centre du montant en bois +/- 1/4 po (6.4 mm) sous une cloison sèche d’une épaisseur de 1/2 à 1 po (12,7 à 25 mm) Précision - Centre du montant en métal +/- 1/4 po (6.4 mm) sous une cloison sèche d’une épaisseur de 1/2 à 1,5 po (12,7 à 38 mm) Précision - Détection d’objets métalliques +/- 3 po (76.2mm) Source de l'alimentation 2 piles AAA (1,5 V) (3 V CC) Durée de vie de la pile < 10 heures d’utilisation continue à < 2,4 V (+/- 0.3V), le voyant DEL d’alimentation clignotera pour indiquer que la pile est faible Calibrage automatique Oui S’éteint automatiquement lorsque vous relâchez le bouton Marche Oui Surface non marquante Humidité relative Oui 35 % à 55 % Température de fonctionnement 32°F à 122°F (0°C à 50°C) Température d'entreposage -4°F à 150°F (-20°C à 66°C) 21 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 21 5/21/2019 3:39:45 PM Índice • Informações sobre o detector • Segurança do usuário • Segurança da bateria • Como instalar baterias AAA • Usando o detector • Manutenção • Solução de problemas • Assistência técnica e reparos • Garantia • Especificações Informações Sobre o Detector O detector DW0350 usa sinais eletrônicos para localizar o centro dos pregos de madeira ou metal, fios AC vivos, ou objetos metálicos (por exemplo, tubulação) na parede ou outros materiais de construção comuns. PT OBSERVAÇÃO: • O detector não detecta objetos em concreto, argamassa, blocos, tijolos, gesso, carpetes, materiais com face de alumínio, superfícies metálicas ou revestimentos cerâmicos. • O detector não detectará tubos de plástico ou PVC. Uma vez que o centro de um pino de madeira ou de metal ou um objeto de metal foi detectado depois de passar através da superfície, o detector DW0350 acende os LEDs centrais e emite um sinal sonoro. Um círculo da marcação permite que você anote facilmente a posição atual na parede. Segurança do Usuário Guia de segurança As definições abaixo descrevem o nível de gravidade representado para cada palavra de sinal. Por favor, leia o manual e preste atenção nestes símbolos.   AVISO: Indica uma situação potencialmente perigosa que, se não for evitada, poderá resultar em ferimentos graves.  UIDADO: Indica uma situação potencialmente perigosa que, se C não for evitada, talvez resulte em ferimentos leves ou moderados. NOTA: Indica uma prática não relacionada a uma lesão corporal, a qual, se não evitada, poderá causar danos materiais. CUIDADO: Proteja seus olhos. Use óculos de segurança. AVISO: Esta ferramenta não é um dispositivo de medição e não deve ser usada como substituto de um voltímetro. AVISO: O símbolo LED ou de detecção de fios mostrado no visor é apenas um indicador e em algumas situações, a opção de detecção de voltagem pode não indicar com exatidão a presença de tensão em uma parede, no caso de falha interna do dispositivo ou operação inadequada. Portanto, não se deve ser apenas confiar unicamente nele para identificar o risco de voltagens. Outras indicações, como desenhos técnicos da construção ou identificação visual de fiações ou conduítes nos pontos de entrada devem também ser utilizados. Sempre siga as instruções de segurança adequadas e use um método de detecção separado para verificar se os cabos estão desligados antes de iniciar o trabalho. AVISO: Sempre desligue a energia AC ao trabalhar perto da fiação. AVISO: Fios blindados ou fios em conduítes metálicos, invólucros, paredes metalizadas ou paredes grossas e densas podem não ser detectados. CUIDADO: Use equipamento de proteção pessoal. Sempre use proteção ocular. Dependendo das condições de trabalho, use equipamentos de proteção pessoal, como máscara contra a poeira, sapatos de segurança antideslizantes, capacete e proteção auditiva para reduzir o risco de lesões corporais. Se tiver perguntas ou comentários sobre esta ou outra ferramenta da AVISO IMPORTANTE DE SEGURANÇA DEWALT® , visite a página www.DEWALT.com. Garanta a detecção adequada de fios energizados. Sempre segure o detector DW0350 somente pela empunhadura. Segure-o entre os dedos e o polegar encostando na palma da mão (Figura C 1 ). AVISO: Leia e entenda todas as instruções. O descumprimento dos Declaração de conformidade do fornecedor avisos e das instruções deste manual pode causar sérias lesões 47 CFR § 2,1077 informações de conformidade corporais. Identificador exclusivo: DW0350 GUARDE ESTAS INSTRUÇÕES Parte responsável – informações de contato dos Estados Unidos AVISO: DEWALT As seguintes informações da etiqueta podem ser encontradas em sua 701 East Joppa Road ferramenta para sua segurança. Towson, Maryland 21286 www.DEWALT.com 22 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 22 5/21/2019 3:39:46 PM Declaração da FCC 5. Pressione ou para testar o detector. Este equipamento foi testado e está em conformidade com os limites • O detector emitirá alarmes sonoros curtos. O LED de alimentação e o de um dispositivo digital de classe B, em conformidade com a parte 15 ícone da bateria no ecrã LCD deve ligar. O LED AC e todos os outros das regras da FCC. Estes limites foram concebidos para fornecer uma ícones na tela LCD devem iluminar por um segundo e, em seguida, proteção razoável contra interferências nocivas em uma instalação desligue. residencial. Este equipamento gera, utiliza e pode irradiar radiofrequência ou , o LED de energia verde se • Sempre que pressionar e, se não for instalado e utilizado de acordo com as instruções, pode acenderá para indicar que as baterias estão boas. Se este LED piscar causar interferências nocivas nas comunicações por radiocomunicação. ou não acender, troque as baterias. Quando a ferramenta estiver Contudo, não há garantia que não ocorram interferências em uma ligada (ON), o nível de carga das baterias aparece no display (Figura instalação específica. Se este equipamento realmente causar interferências A 7 ). prejudiciais na recepção de televisão ou rádio, o que pode ser verificado ao ligar e desligar o equipamento, o usuário deve tentar corrigir as interferências realizando uma ou mais das seguintes medições: - Reoriente ou reposicione a antena de recepção em outra posição. O detector o ajudará a encontrar pinos de madeira ou metal, voltagem AC - Aumente a distância entre o equipamento e o receptor. presente, e objetos metálicos (por exemplo, tubulação) em uma parede. - Ligue o equipamento na tomada em um circuito diferente (não deve ser o mesmo circuito ao qual o receptor está ligado). • O detector tem dois botões. Usuário o botão inferior (Figura A 3 ) para - Consulte o fornecedor ou um técnico de rádio/televisão para obter ajuda. procurar por pregos de madeira/metal ou AC, e use o botão superior (Figura A 2 ) para procurar objetos metálicos (por exemplo, pipe). Como Usar o Detector Segurança da Bateria AVISO: As baterias podem explodir ou vazar substâncias, e causar ferimentos graves ou incêndio. Para reduzir o risco: • Siga SEMPRE todas as instruções e avisos indicados na etiqueta e na embalagem das baterias. • S  empre insira as baterias corretamente em relação à polaridade (+ e –), como marcado na bateria e no equipamento. • Não provoque um curto-circuito nos terminais das baterias. • Não carregue baterias descartáveis. • O detector detectará pregos de madeira com o drywall grosso de até 1“ (25mm), e os pregos do metal e a tensão de C.A. com até 1,5“ (38mm) o drywall grosso. • O detector detectará um objeto de metal ferroso (contém ferro) até 3“ (76,2 mm) da superfície da parede para o centro do objeto. PT • O detector detectará. O detector detectará um objeto metálico não ferroso (por exemplo, cobre) até 2“ (51 mm) da superfície da parede até o centro do objeto. • Quando a tensão AC for encontrada, o detector emitirá alarmes sonoros curtos (alternados) e acenderá o LED AC (Figura A 5 ) e mostrar o ícone AC na tela LCD (Figura A 4 ). • Quando o centro de um pino for encontrado (ou um objeto metálico está nas proximidades), o detector emitirá um sinal sonoro mais longo na tela LCD (Figure A 4 ). (constante) e exibir as setas do centro • Não misture baterias novas e antigas. Substitua todas as baterias ao mesmo tempo por novas da mesma marca e do mesmo tipo. • Retire as baterias descarregadas imediatamente e descarte-as de acordo • Quando o AC energizado e o centro de um pino forem encontrados, o com os códigos locais. na tela detetor alterará entre os bipes longos e curtos, exibir e • Não descarte as baterias no fogo. LCD, e iluminar o LED AC. • Mantenha as baterias longe do alcance das crianças. Como Encontrar um Pino Como Instalar Baterias AAA Carregue as baterias novas no detector AAA no DW0350. 1. Na parte inferior do sensor de vigas, levante a patilha (Figura para desbloquear a tampa do compartimento da bateria. 2. Mova a tampa para cima (Figura separar do detector. 3. Insira duas pilhas AAA novas de marca de alta qualidade, certificandose de posicionar as extremidades - e + de cada bateria como no compartimento (Figura B 3 ). 4. Coloque a tampa de volta no detector (Figura B 2 B 1 Para segurar o detector, coloque o polegar em um lado do detector, o dedo indicador e a palma da mão sobre o centro do detector, e o resto dos dedos na mesma mão do outro lado do detector (Figura C 1 ). 2. Coloque delicadamente o detector contra a parede e paralelamente a uma porta ou janela na mesma parede. Isso lhe dará uma indicação de como os metais estão posicionados atrás da parede (Figura C 2 ). 3. Sem mover o detector, use o dedo indicador para pressionar e segurar (Figura A 3 ). AGUARDE 1 seg até que todos os LEDS (exceto o LED de energia) desligam e todos os ícones na tela LCD desligar, exceto o nível da bateria. 4. Enquanto estiver pressionando , LENTAMENTE mova o detector para a esquerda ou para a direita na parede. ) ) e a remova assim que ela se B 4 1. ). • Insira os dois pinos na parte superior da tampa nos furos perto da parte superior do compartimento da bateria. • Abaixe lentamente a tampa e pressione para baixo até que a trava se trave firmemente no detector. 23 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 23 5/21/2019 3:39:47 PM Ao mover o detector, observe as setas exibidas na tela LCD e ouça os alarmes sonoros. 5. 5. e aparecerem no do ecrã LCD, mova o detector para a • Se direita ou para a esquerda para encontrar o objeto metálico (Figura F 1 ). aparecerem no lado direito da tela LCD • Se as setas remotas (Figura D 1 ), continue movendo o detector para a direita para encontrar o pino mais próximo. Como você chegar mais perto do pino, aparece na tela LCD (Figura D 2 ). aparecerem no lado esquerdo da tela LCD, • Se as setas remotas continue movendo o detector para a esquerda para encontrar o pino mais próximo. Como você chegar mais perto do pino, aparece na tela LCD. e aparecerem no do ecrã LCD, você vai saber que • Se você está movendo o detector mais perto do objeto metálico (Figura F 2 ). 6. • Se a tensão AC for encontrada dentro de 12”- 18” (0,3 m - 0,5 m) da posição atual do detector, o LED AC acenderá, aparecerem no do ecrã LCD, e você ouvirá alarmes sonoros curtos. NOTA: As cargas elétricas estáticas, que podem se desenvolver em paredes de gesso e outras superfícies, espalharão a área de detecção de voltagem em muitas polegadas para todos os lados do fio elétrico em questão. Isto pode fazer com que o detector indique que encontrou C.A. viva quando não está realmente perto de um fio elétrico (Figura E 1 ). Para ajudar a localizar a posição do fio, coloque a outra mão na sua superfície aproximadamente 12’’ (30cm) do sensor (Figura E 2 ) ou faça uma varredura segurando a unidade ½ - 2 (13mm - 50mm) da superfície da parede. PT Quando as setas do centro aparecem na tela LCD e você ouvir um sinal sonoro constante, significa que o detector encontrou o centro de um pino (Figura D 3 ). 6. Ao mover detector, observe as setas exibidas na tela LCD. Quando as setas do centro aparecem na tela LCD e você ouvir um sinal sonoro constante, significa que o detector encontrou objeto metálico dentro de 3 “(76,2 mm) à esquerda ou à direita da posição atual (Figura F 3 ). • PARE de mover o detector e continue a segurá-la na posição atual. • PARE de pressionar 7. . Passando pelo círculo no detector (Figura lápis a posição atual. F 4 ), marque com um • O objecto metálico pode estar dentro de 3 “(76,2 mm) à esquerda ou à direita da marca. • Para a posição exata do objeto metálico, você deve referir-se a desenhos de construção. 8. Para encontrar outro objeto metálico na parede, repita os mesmos procedimentos. Manutenção NOTA: Se a tensão AC for encontrada perto do centro de um • Quando o detector não estiver em uso, limpe as partes externas com um aparecerem no do ecrã LCD, pino, o LED AC acenderá, e pano úmido, limpe o detector com um pano macio e seco para ter certeza e o detector emitirá o alarme sonoro curto alternado (AC encontrado) de de que esteja seco. pois outro mais constante e longo (centro do pino encontrado). • Embora o exterior do detector seja resistente a solventes, NUNCA use solventes para limpar o detector. • PARE de mover o detector e continue a segurá-la na posição atual. • PARE de pressionar . 7. Passando pelo círculo no detector (Figura D lápis a posição atual como o centro do pino. 8. Para encontrar outro pino na parede, repita os mesmos procedimentos. 4 ), marque com um Como Encontrar Objetos do Metal O detector vai deixar você saber se um objeto de metal (por exemplo, um tubo) está localizado atrás da parede dentro de 3” do detector. No modo de detecção de metal, as setas não indicam qual direção mover o detector para encontrar metal. 1. 2. 3. 4. Para segurar o detector, coloque o polegar em um lado do detector, o dedo indicador e a palma da mão sobre o centro do detector, e o resto dos dedos na mesma mão do outro lado do detector (Figura C 1 ). Posicione o detector contra a parede e paralelamente a uma porta ou janela na mesma parede. Isso lhe dará uma indicação de como os metais estão posicionados atrás da parede (Figura C 2 ). • Armazene o detector em um local limpo a uma temperatura entre -67 ˚F (-55 ˚C) e 158 ˚F (70 ˚C). Solução de Problemas O LED está piscando Se o LED de alimentação está piscando (e o nível da bateria no ecrã LCD está piscando), a bateria está acabando. • Verifique as baterias AAA para garantir que: • Cada bateria esteja instalada corretamente, de acordo com + e dentro do compartimento da bateria. • Os contatos da bateria estejam limpos sem ferrugem ou corrosão. • As baterias sejam novas e de alta qualidade para reduzir as chances de vazamento da bateria. • Certifique-se de que as pilhas AAA estejam em boas condições de funcionamento. Em caso de dúvida, tente instalar novas baterias. LED não liga Sem mover o detector, use o dedo indicador para pressionar e segurar O (Figura A 2 ). Após 1 seg, todos os LEDS (exceto o LED de Se o LED de alimentação não ligar, ou o LED de alimentação acender energia) desligam e todos os ícones na tela LCD desligar, exceto o durante 1 seg e, em seguida, desligar, não existe energia da bateria. nível da bateria e . • Instale duas baterias novas, de alta qualidade e de marca renomada AAA Enquanto estiver pressionando , LENTAMENTE mova o detector no detector. para a esquerda ou para a direita na parede. • Certifique-se de que cada bateria esteja instalada corretamente, de acordo com + e - esteja dentro do compartimento da bateria. 24 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 24 5/21/2019 3:39:48 PM O detector não está encontrando pinos • Certifique-se de que as baterias estejam funcionamento. • Certifique-se de ter colocado o detector em uma parede ou outro material de construção comum. O detector não funcionará em paredes de concreto, argamassa, blocos, tijolos, gesso, carpetes, materiais com face de alumínio, superfícies metálicas ou revestimentos cerâmicos. • Certifique-se de que tenha colocado o detector contra a parede, o detector esteja na posição vertical (paralelo a uma porta ou janela), (Figura A 3 ), e que você esteja pressionando e segurando movendo ao mesmo tempo o detector LENTAMENTE contra a parede. • Certifique-se de que a parede não seja muito grossa. O DW0100 pode ser usado em paredes de até < 0,75” (19 mm) de espessura e o DW0150 pode ser usado em parede com menos de <1,5” (38 mm) espessura. • Certifique-se de que a parede tenha uma superfície lisa. • Cerifique-se que a temperatura esteja dentro da faixa operacional especificada e da umidade relativa. O detector não está encontrando Objetos do Metal • Certifique-se de que as baterias estejam funcionamento. • Certifique-se de ter colocado o detector em uma parede ou outro material de construção comum. O detector não funcionará em paredes de concreto, argamassa, blocos, tijolos, gesso, carpetes, materiais com face de alumínio, superfícies metálicas ou revestimentos cerâmicos. PT • Certifique-se de que tenha colocado o detector contra a parede, o detector esteja na posição vertical (paralelo a uma porta ou janela), (Figura A 2 ), e que você esteja pressionando e segurando movendo ao mesmo tempo o detector LENTAMENTE contra a parede. • Certifique-se de que a parede não seja muito grossa. O DW0350 pode ser usado para detect não ferrosos (por exemplo, cobre) metais em paredes de até 2 “(51mm) de espessura e metal ferroso (contem o ferro) até 3 “(76,2 mm) espessura. • Certifique-se de que a parede tenha uma superfície lisa. • Cerifique-se que a temperatura esteja dentro da faixa operacional especificada e da umidade relativa. Assistência Técnica e Reparos Nota: Desmontar o instrumento anula todas as garantias do produto. Para garantir a SEGURANÇA e CONFIABILIDADE do produto, os reparos, a manutenção e os ajustes devem ser realizados por centros de assistência técnica autorizados. A assistência técnica ou manutenção realizada por pessoal não qualificado pode oferece riscos de lesões. Para localizar um centro de assistência técnica DEWALT MAIS PRÓXIMO DE VOCÊ, acesse www.DEWALT.com. Garantia Acesse www.DEWALT.com para obter as informações de garantia mais recentes. 25 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 25 5/21/2019 3:39:49 PM Especificações DW0350 Detectar pinos de madeira paredes de até 1” (25 mm) de espessura Detectar pinos de metal Detectar Fio AC energizado 110V @ 60 Hz (220V @ 50Hz) paredes de até 2” (51 mm) de espessura até paredes de 2” (51 mm) espessura de uma distância de 6”-18” (0,15 m - 0,5 m) o LED AC ascenderá Detecte o metal ferroso (contem o ferro) até 3 “(76,2 mm) da superfície da parede para o centro do objeto metálico (pipe) Detecte metais não ferrosos (por exemplo, cobre) Exatidão - Centro do pino de madeira até 2 “(51mm) da superfície da parede para o centro do objeto metálico (pipe) parede de +/- 1/4” (6.4 mm) menor que 1/2” - 1,5” (12,7 mm - 38 mm) de espessura Exatidão - Centro do pino de metal Exatidão - Detecção de rastreamento de metal Fonte de potência PT Vida da bateria parede de +/- 1/4” (6.4 mm) menor que 1/2” - 1,5” (12,7 mm - 38 mm) de espessura +/- 3” (76.2mm) 2 AAA (1.5V) baterias de tamanho (3V DC) < 10 horas de uso contínuo a <2,4 V (+/- 0,3 V), energia de LED piscará para indicar bateria fraca Calibração automática Sim Desligamento automático ao soltar o botão Ligar Sim Não causa danos à superfície Umidade relativa Sim 35% - 55% Temperatura Operacional 32°F to 122°F (0°C to 50°C) Temperatura de armazenamento -4°F to 150°F (-20°C to 66°C) 26 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 26 5/21/2019 3:39:49 PM Notes: DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 27 5/21/2019 3:39:49 PM © 2019 DEWALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286 See product for country of origin statement. N663828 May 2019 DEWALT MPP3 STUD SENSOR - DW0350 - User Manual - NA - MAY 2019.indd 28 5/21/2019 3:39:49 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

DeWalt DW0350 Manual de usuario

Tipo
Manual de usuario