Eaton E5324E Series Operating Instructions Manual

Categoría
Medir, probar
Tipo
Operating Instructions Manual
Operating instructions
Digital display with analog inputs
E5324E Series
1. Description
5 digit digital display with analog inputs
LED-Display with 8 mm [0.31 in] high
characters and very high luminosity
Display range -19999 – 99999 with leading
zero blanking
Programming of functions and operating
parameters via the setting keys. During pro-
gramming the display guides the user with text
prompts.
Programmable features:
Range
Max. value display yes/no
Max. value reset yes/no
Min. value display yes/no
Min. value reset yes/no
Decimal point
Min. input signal
Displayed value at min. input signal
Max. input signal
Displayed value at max. input signal
2. Inputs
LATCH (Connect 4)
Static input to freeze the displayed value.
If this input (pnp) is supplied with
4 – 30V DC, the actual value is frozen
until the input is released or the signal
level gets below 2V DC. The calculating
of max. and min. value is not af fec ted.
CURRENT INPUT (Connect 5)
Analog current input with reverse connec-
tion pro tec tion and current limitation to
max. 50 mA. Connect the signal line with
the analog + signal with this input.
CAUTION: To prevent interfering signals
caused by the supply voltage, this input is
isolated from the supply voltage. Connect
the signal line with the - Signal to the ana-
log reference input.
ANALOG GND
(Connect 6)
If no isolation between measuring circuit
and supply voltage is necessary, connect
pin 2 or 3 to this input.
VOLTAGE INPUT
(Connect 7)
Analog voltage input. Connect the signal
line with the analog + signal with this
input. In case of reverse connection, the
display shows “Err4”.
CAUTION: To prevent interfering signals
caused by the supply voltage, this input is
isolated from the supply voltage. Connect
the signal line with the - Signal to the
ana log reference input.
deutsch
français english
español
MN05401008E 1
3. Setting of the parameters
3.1 Selecting the displayed value
By pressing the right key, the display can
be switched between the current, min., or
max. value.
Press the right key once to display the
current function (“Act”, “Min” or “Max”) for
2 seconds. If within this period the right
key is pressed again, the current function
is changed. The display shows the new
current function for two seconds.
Afterwards the corresponding value is dis-
played. If “Min” or “Max” is the current
function, the value can be reset by press-
ing the left key. If neither storing of min.
nor max. value is activated in setup, both
keys are out of function.
3. 2 Setting the operating parameters
a. Hold down both keys on front panel and
switch on the supply voltage.
b. The display shows:
c. After releasing the keys the display alternates
between menu title and corresponding menu
item at a frequency of 0.5 Hz. After any key is
pressed, only the menu item is displayed.
d. Press the right key to switch the menu item to
next value.
e. Hold down the left key and press the right key
to switch to the next menu title.
f. After programming the last menu item, the
programming routine will be exited and the
new values will be stored by switching the
menu item to “YES”. If you choose “NO”, the
programming routine will be passed through
once again.
4. Programming routine
Programmable parameters are shown in
succession. After one pass, the device is
fully programmed.
In each case the first shown item is the
factory preset.
4.1 Range of input signal
0 – 20 mA
4 – 20 mA
0 – 10V
2 – 10V
4.2 Max. value display
4.3 Max. value reset
Max. value can be
dis play ed
Max. value wonʼt be
dis play ed, next menu
title is skipped
Max. value can be reset
by pressing left button.
(Cur rent value becomes
new max. value)
Max. value canʼt be
reset.
4.4 Min. value display
Min. value can be displayed
Min. value wonʼt be
dis play ed, next menu
title is skip ped
2 MN05401008E
4.5 Min. value reset
Min. value can be reset
by pressing left button.
(Cur rent value becomes
new min. value)
Min. value canʼt be reset.
4.6 Decimal point
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
0.0000 four decimal places
The decimal point indicates
the num ber of decimal
places.
4.7 Min. input signal (only if input
signal range is 4 – 20 mA or 2 – 10V)
This menu title allows a limitation of the
display range (see 4.9).
a) If the input signal level
at input range 4 – 20
mA goes below this
value, the display
shows “lo”.
b) If the input signal level
at input range 2 – 10V
goes below this value,
the display shows “lo”.
Depending on chosen input
range a) or b) is selected.
4.8 Displayed value at min. input signal
A corresponding
display value between
-19999 and 99999
can be as si gned to
the lowest input sig-
nal. The decimal
pointʼs position is
considered.
4.9 Max. input signal (only if input
signal range is 4 – 20 mA or 2 – 10V)
This menu title allows a limitation of the
display range.
Depending on chosen input
range a) or b) is selected.
4.10 Displayed value at max. input signal
A corresponding display
value between -19999
and 99999 can be as si -
gned to the highest input
signal. The decimal
pointʼs po si ti on is
considered.
english
MN05401008E 3
a) If the input signal level
at input range 4 – 20
mA goes above this
value, the display
shows “high”.
b) If the input signal level
at input range 2 – 10V
goes above this value,
the display shows
“high”.
5. Connections
1 10 – 30V DC
2GND
3GND
4LATCH
5 0 (4) – 20 mA
6 Analog GND
7 0 (2) – 10V DC
4.11 End of programming
Programming routine will
be passed through once
again. All parameters
can be checked.
Programming routine will
be exited and the new
pa ra me ters will be
stored. Af ter wards the
device is ready to use.
6. Technical data
Display: 5 digit 7 segment red
LED-Display,
8 mm [0.31 in.]
high characters
Range of input signals
0 – 10V DC
2 – 10V DC
0 – 20 mA DC
4 – 20 mA DC
Resolution: 14 Bit
Linearity: < 0.1% ± 1 digit at an
ambient temperature of
20°C [68°F]
Zero adjustment:
automatic
Temperature drift:
<70ppm/K
Measuring rate:
0.5 – 2 Measurement/sec
Current measuring:
Voltage drop:
max. 2.0V at 20 mA
Current limitation: 50 mA
Voltage measurement:
Input resistance: >1 MΩ
Elimination of power line hum:
digital filter at 50 Hz
Supply voltage:
10 – 30V DC,
galvanically isolated
Current consumption:
max. 50 mA
Ambient temperature:
-10°C to 50°C
[14 to 122°F]
Storage temperature:
-25°C to 70°C
[-9 to 158°F]
Data retention:
via EEPROM 1 Million
memory cycles or 10 years
Weight: ca. 50 g [1.76 oz.]
Front panel rating: IP 65
EMC:
EN 61000-4-2/EN 55011 Class B
EN 61000-6-2
Cleaning:
The front of the unit is only to be cleaned
with a soft cloth moistened with water.
Error messages:
Err 0* Error/defect in A/D-part
Err 3* Error/defect EEPROM
Err 4** Analog input overflow
Err 5* Error/defect EEPROM.
Device not calibrated
* Please send the device back for checking
** Please check input signal and programming
7. Contents:
- Digital display with analog inputs
- Panel mounting clip
- Bezel for screw mount, panel cut-out
50x25 mm [1.97 x 0.98 in.]
- Bezel for clip mount, panel cut-out
50x25 mm [1.97 x 0.98 in.]
- Sealing
- Tack dry symbols
4 MN05401008E
english
MN05401008E 5
8. Examples:
8.1 Temperature measurement
A temperature sensor with linear charac-
teristic (non-linear sensors, e.g. thermo-
couples need to be linearized) supplies
0V at -10°C [14°F] and 10V at 80°C
[176°F]. 0 – 10V is chosen as input
range.
Assign -10 as “displayed value at min.
input signal” to the lo west input level (0V)
and 80 as “displayed value at max. input
signal” (10V). The device is now tuned to
the sensor, and measurement values and
their corresponding display values in bet -
ween are calculated.
Displayed value can be freely
adjusted to the input value inside
the display range.
8.2 Level measurement
A level sensor with linear characteristic
(non-linear sen sors ha ve to be li nea ri zed)
supplies 19 mA at full tank and 5 mA at
empty tank. If the tank is filled up, 10 m
3
should be displayed and if the tank is
empty 0 m
3
should be displayed.
4 – 20 mA is chosen as input range.
Assign 0 as “displayed value at min. input
signal” to the lo west input level (5 mA)
and 10 as “displayed value at max. input
signal” (19 mA). The device is now tu ned
to the sensor, and measurement values
and their cor re spon ding display values in
bet ween are cal cu la ted.
8.3 Drawn quantity
Instead of the level, the drawn quantity
should be displayed.
Again 4 – 20 mA is chosen as input
range. Assign 10 as “displayed value at
min. input signal” to the lo west input level
(5 mA) and 0 as “displayed value at max.
input signal” (19 mA).
Min. input
voltage or
min. input
current can
be shifted
inside the
input voltage
range or the
input current
range.
Max. input
voltage or
max. input
current can be
shifted inside
the input volt-
age range or
the input cur-
rent range.
Displayed value can be
freely adjusted to the
input value inside the
display range.
8.4 Level measurement with limited
display range
A third example is level measurement
with limited display range, that means a
tank with 10 m
3
has to be filled up at
most to 8 m
3
and its the level should not
decrease below 1 m
3
. At values > 8 m
3
the dis play shows “hi” and at values <
1m
3
the display shows “lo”.
4 – 20 mA is chosen as input range.
Assign 0 as “displayed value at min. input
signal” to the lo west input level and 10 as
“displayed va lue at max. input signal” to
the highest input level.
Additionally at menu title “min. input
signal” the value which cor re sponds
to the 1 m
3
level, e.g. 5.6 mA is
pro gram med. Do the same with the
va lue which cor re sponds to the 8 m
3
level, e.g. 16.8 mA.
At input levels > 16.8 mA “hi” will be dis-
played and at input levels < 5.6 mA “lo”.
6 MN05401008E
MN05401008E 7
español
Instrucciones de operación
Pantalla digital con entradas
analógicas
Serie E5324E
1. Descripción
Pantalla digital de 5 dígitos con entradas
analógicas
Pantalla LED con caracteres de 8 mm
[0,31 pulg.] de altura y de gran luminosidad
Rango de pantalla de -19999 a 99999 con
supresión de cero inicial
Programación de funciones y parámetros de
operación por medio de las teclas de
configuración. Durante la programación, la
pantalla guía al usuario con indicaciones de
texto.
Funciones programables:
Rango
Mostrar valor máx. sí/no
Restablecer valor máx. sí/no
Mostrar valor mín. sí/no
Restablecer valor mín. sí/no
Punto decimal
Señal de entrada mín.
Valor mostrado en señal de entrada mín.
Señal de entrada máx.
Valor mostrado en señal de entrada máx.
2. Entradas
RETENCIÓN (conexión 4)
Entrada estática para congelar el valor que
se muestra. Si a esta entrada (pnp) se le
proporciona 4 – 30 V CC, el valor real se
congela hasta que se libera la entrada o
el nivel de la señal baja a menos de
2 V CC. No se ve af ect ado el cálculo de
los valores máximos y mínimos.
ENTRADA DE CORRIENTE (conexión 5)
Entrada de corriente analógica con
pro tec ción de conexión inversa y límite
de corriente en un máximo de 50 mA.
Conecte la línea de señal con la señal
analógica + a esta entrada.
PRECAUCIÓN: Para evitar las señales
perturbadoras que produce el voltaje de
suministro, esta entrada se aísla del
voltaje de suministro. Conecte la línea
de señal con la señal analógica - a la
entrada de referencia analógica.
CONEXIÓN A TIERRA ANALÓGICA
(conexión 6)
Si no es necesario usar aislamiento entre
el circuito de medición y el voltaje de
suministro, conecte la clavija 2 ó 3 a esta
entrada.
ENTRADA DE VOLTAJE (conexión 7)
Entrada de voltaje analógica. Conecte la
línea de señal con la señal analógica + a
esta entrada. En caso de que haya una
conexión inversa, la pantalla muestra
“Err4”.
PRECAUCIÓN: Para evitar las señales
perturbadoras que produce el voltaje de
suministro, esta entrada se aísla del
voltaje de suministro. Conecte la línea
de señal con la señal analógica - a la
entrada de referencia analógica.
8 MN05401008E
3. Configuración de los
parámetros
3.1 Selección del valor que se muestra
Al presionar la tecla derecha, la pantalla
puede cambiar entre el valor de corriente
mínimo o máximo.
Presione una vez la tecla derecha para
mostrar la función de corriente (“Act”,
“Min” o “Max”) durante 2 segundos. Si
dentro de este período se vuelve a
presionar la tecla derecha, cambia la
función de corriente. La pantalla muestra
la nueva función de corriente durante dos
segundos. Luego, se muestra el valor
correspondiente. Si “Min” o “Max” es
la función de corriente, el valor se
puede restablecer presionando la tecla
izquierda. Si no está activado el
almacenamiento del valor mínimo o
máximo en la configuración, ambas teclas
están fuera de función.
3. 2 Configuración de los parámetros
de operación
a. Mantenga presionadas ambas teclas del panel
delantero y encienda el voltaje de suministro.
b. La pantalla muestra:
c. Luego de soltar las teclas, la pantalla alterna
entre el título del menú y el elemento del
menú correspondiente en una frecuencia de
0,5 Hz. Después de que se presione cualquier
tecla, sólo se muestra el elemento del menú.
d. Presione la tecla derecha para cambiar el
elemento del menú al valor siguiente.
e. Mantenga presionada la tecla izquierda y
presione la tecla derecha para cambiar al
siguiente título de menú.
f. Después de programar el último elemento de
menú, se cerrará la rutina de programación y
se almacenarán los nuevos valores
cambiando el elemento de menú a “YES”. Si
escoge “NO”, la rutina de programación se
iniciará una vez más.
4. Rutina de programación
Los parámetros programables se
muestran en secuencia. Después de una
pasada, el dispositivo está
completamente programado.
En cada caso, el primer elemento que se
muestra es el valor preconfigurado en
fábrica.
4.1 Rango de la señal de entrada
0 – 20 mA
4 – 20 mA
0 – 10 V
2 – 10 V
4.2 Mostrar valor máximo
4.3 Restablecer valor máximo
Se puede mostr ar el
valor máximo
No se mostra rá el valor
máximo, se omite el
siguiente título de menú
Se puede restablecer
el valor máximo
presionando el botón
izquierdo. (El valor de
co rriente se convierte en
el nuevo valor máximo)
No se puede restablecer
el valor máximo.
4.4 Mostrar valor mínimo
Se puede mostrar el valor
mínimo
No se mostra rá el valor
mínimo, se omi te el
siguiente título de menú
MN05401008E 9
español
4.5 Restablecer valor mínimo
Se puede restablecer el
valor mínimo presionando
el botón izquierdo. (El
valor de co rriente se
convierte en el nuevo
valor mínimo)
No se puede restablecer
el valor mínimo.
4.6 Punto decimal
0 ninguna cifra decimal
0.0 una cifra decimal
0.00 dos cifras decimales
0.000 tres cifras decimales
0.0000 cuatro cifras
decimales
El punto decimal indica el
núm ero de cifras decimales.
4.7 Señal de entrada mínima
(sólo si el rango de la señal de
entrada es 4 – 20 mA ó 2 – 10 V)
Este título de menú permite limitar el
rango de pantalla (consulte 4.9).
a) Si el nivel de señal de
entrada en el rango de
entrada 4 – 20 mA es
menor que este valor,
la pantalla muestra “lo”
(bajo).
b) Si el nivel de señal de
entrada en el rango de
entrada 2 – 10 V es
menor que este valor,
la pantalla muestra “lo”.
Dependiendo del rango de
entrada que se escoja, se
selecciona a) o b).
4.8 Valor mostrado en señal de entrada
mínima
Se puede a sig nar un
valor de pantalla
correspondiente entre
-19999 y 99999 a la
señal de entrada más
baja. Se considera la
posición del punto
decimal.
4.9 Señal de entrada máxima
(sólo si el rango de la señal de
entrada es 4 – 20 mA ó 2 – 10 V)
Este título de menú permite limitar el
rango de pantalla.
Dependiendo del rango de
entrada que se escoja, se
selecciona a) o b).
4.10 Valor mostrado en señal de entrada
máxima
Se puede asignar un
valor de pantalla
correspondiente entre
-19999 y 99999 a la
señal de entrada más
alta. Se considera la
po si ci ón del punto
decimal.
a) Si el nivel de señal de
entrada en el rango de
entrada 4 – 20 mA
supera este valor, la
pantalla muestra “high”
(alto).
b) Si el nivel de señal de
entrada en el rango de
entrada 2 – 10 V
supera este valor, la
pantalla muestra “high”.
10 MN05401008E
5. Conexiones
1 10 – 30 V CC
2 CONEXIÓN A TIERRA
3 CONEXIÓN A TIERRA
4 RETENCIÓN
5 0 (4) – 20 mA
6 Conexión a tierra
analógica
7 0 (2) – 10 V CC
4.11 Fin de la programación
La rutina de
programación se iniciará
una vez más. Se
pueden verificar todos
los parámetros.
Se cerrará la rutina de
programación y se
almacenarán los nuevos
pa me tros. Des pu és de
eso, el dispositivo está
listo para su uso.
6. Datos técnicos
Pantalla: Pantalla LED roja de
5 dígitos y 7 segmentos
con caracteres de 8 mm
[0,31 pulg.] de altura
Rango de señales de entrada
0 – 10 V CC
2 – 10 V CC
0 – 20 mA CC
4 – 20 mA CC
Resolución: 14 bits
Linealidad: < 0,1% ± 1 dígito a
temperatura ambiente de
20° C [68° F]
Ajuste a cero: automático
Deriva térmica:
<70 ppm/K
Velocidad de medición:
0,5 – 2 medición/seg.
Medición de corriente:
Caída de voltaje: 2,0 V a
20 mA como máximo
Límite de corriente: 50 mA
Medición de voltaje:
Resistencia de
entrada: >1 MΩ
Eliminación de zumbido de la línea de
alimentación:
Filtro digital a 50 Hz
Voltaje de suministro:
10 – 30 V CC, aislado
galvánicamente
Consumo de corriente:
50 mA como máximo
Temperatura ambiente:
-10° C a 50° C [14° a 122° F]
Temperatura de almacenamiento:
-25° C a 70° C [-9 a 158° F]
Retención de datos:
Vía EEPROM 1 millón de
ciclos de memoria o 10 años
Peso: ca. 50 g [1,76 oz.]
Clasificación del panel delantero: IP 65
EMC:
EN 61000-4-2/EN 55011 Clase B
EN 61000-6-2
Limpieza:
La parte delantera de la unidad sólo se
debe limpiar con un paño suave
humedecido con agua.
Mensajes de error:
Err 0* Error/Defecto en la pieza A/D
Err 3* Error/Defecto en la EEPROM
Err 4** Exceso en la entrada
analógica
Err 5* Error/Defecto en la
EEPROM. Dispositivo sin
calibración
* Envíe de vuelta el dispositivo para su
revisión
** Verifique la señal de entrada y la
programación
MN05401008E 11
español
7. Contenido:
- Pantalla digital con entradas analógicas
- Abrazadera de montaje del panel
- Bisel para montaje con tornillos, plantilla
de recorte del panel de 50 x 25 mm
[1,97 x 0,98]
- Bisel para montaje con abrazadera,
plantilla de recorte del panel de 50 x
25 mm [1,97 x 0,98]
- Sellado
- Símbolos adhesivos en seco
8. Ejemplos:
8.1 Medición de temperatura
Un sensor de temperatura con
característica lineal (sensores no lineales,
por ej., los termopares se deben
linearizar) suministra 0 V a -10° C [14° F]
y 10 V a 80° C [176° F]. Se escoge 0 –
10 V como rango de entrada.
Asigne -10 como “valor mostrado en
señal de entrada mínima” al nivel de
entrada más ba jo (0 V) y 80 como “valor
mostrado en señal de entrada máxima”
(10 V). Ahora el dispositivo está
sintonizado según el sensor, y se
calculan los valores de medición y sus
valores intermedios respectivos que se
muestran.
El valor que se muestra se puede
ajustar libremente en el valor de
entrada dentro del rango de
pantalla.
8.2 Medición de nivel
Un sensor de nivel con característica
lineal (los sen sores no lineales se de ben
li nea ri zar) suministra 19 mA con tanque
lleno y 5 mA con tanque vacío. Si el
tanque está lleno, se debe mostrar 10 m
3
y si el tanque está vacío, se debe mostrar
0 m
3
. Se escoge 4 – 20 mA como rango
de entrada.
Asigne 0 como “valor mostrado en señal
de entrada mínima” al nivel de entrada
más ba jo (5 mA) y 10 como “valor
mostrado en señal de entrada máxima”
(19 mA). Ahora el dispositivo está
sin tonizado según el sensor, y se
cal cu lan sus valores inter medios y los
valores de medición res pec ti vos que se
muestran.
8.3 Cantidad extraída
En lugar del nivel, se debe mostrar la
cantidad extraída.
Nuevamente, se escoge 4 – 20 mA como
rango de entrada. Asigne 10 como “valor
mostrado en señal de entrada mínima” al
nivel de entrada más ba jo (5 mA) y 0
como “valor mostrado en señal de
entrada máxima” (19 mA).
12 MN05401008E
El voltaje de
entrada mínimo
o la corriente
de entrada
mínima se
pueden
cambiar dentro
del rango de
voltaje de
entrada o del
rango de
corriente de
entrada.
El voltaje de
entrada máximo
o la corriente de
entrada máxima
se pueden
cambiar dentro
del rango de
voltaje de
entrada o del
rango de
corriente de
entrada.
El valor que se muestra se
puede ajustar libremente en
el valor de entrada dentro del
rango de pantalla.
8.4 Medición de nivel con rango de
pantalla limitado
Un tercer ejemplo es la medición de nivel
con rango de pantalla limitado, lo que
significa que un tanque con 10 m
3
se
debe llenar como máximo en 8 m
3
y su
nivel no debe ser menor que 1 m
3
. En
valores > 8 m
3
, la pan talla muestra “hi” y
en valores < 1 m
3
, la pantalla muestra “lo”.
Se escoge 4 – 20 mA como rango de
entrada.
Asigne 0 como “valor mostrado en señal
de entrada mínima” al nivel de entrada
más ba jo y 10 como “va lor mostrado en
señal de entrada máxima” al nivel de
entrada más alto.
Adicionalmente, en el título de menú
“min. input signal” (señal de entrada mín.)
el valor que cor res ponde al nivel 1 m
3
,
por ej., 5,6 mA se pro gra ma. Haga lo
mismo con el va lor que corresponda al
nivel 8 m
3
, por ej., 16,8 mA.
En niveles de entrada > 16,8 mA, se
mostrará “hi” y en niveles de entrada
< 5,6 mA, “lo”.
MN05401008E 13
français
1. Description
Affichage digital à 5 chiffres avec entrées
analogiques
Affichage par LED hauteur 8 mm à haute
luminosité pour une lecture aisée.
Plage dʼaffichage de -19999 à 99 999 avec
suppression des zéros non significatifs
Programmation des paramètres de
fonctionnement à lʼaide des deux
boutons-poussoirs. Lʼaffichage indique
en abrégé les différents paramètres.
Peuvent être programmés :
La plage de mesure
Lʼaffichage de la valeur maximum oui/non
La redéfinition de la valeur maximum oui/non
Lʼaffichage de la valeur minimum oui/non
La redéfinition de la valeur minimum oui/non
Le point décimal
Le signal dʼentrée minimum
La valeur à afficher dans le cas du signal
dʼentrée le plus petit
Le signal dʼentrée maximum
La valeur à afficher dans le cas du signal
dʼentrée le plus grand
2. Entrées
LATCH (Raccordement 4)
Entrée statique de blocage dʼaffichage.
Lors de son ac ti va tion (pnp) par un signal
de niveau 10 à 30 V DC ; la valeur de
mesure instantanée est figée jusquʼà ce
que cette entrée soit libérée ou que le
niveau du signal des cen de en-dessous
de 2 V DC. La détermination des valeurs
minimum et maximum continue en
arrière-plan.
ENTREE EN COURANT
(Raccordement 5)
Entrée analogique de mesure de courant
avec pro tec tion contre lʼinversion de
polarité et li mi ta tion du courant à 50 mA
maximum. Connecter ici le conducteur du
si gnal ana lo gi que +.
Attention : Cette entrée est isolée
élec tri que ment afin dʼéviter les signaux
parasites véhiculés par la tension
dʼali men ta tion. Il faut donc relier, pour la
mesure, le con duc teur du signal le plus
négatif à lʼentrée de masse ana lo gi que de
ren ce.
ANALOGIQUE GND
(Raccordement 6)
entrée de référence analogique
Dans le cas où il nʼy a pas lieu dʼavoir
une iso la tion gal va ni que entre la boucle
de mesure et la tension dʼali men ta tion,
effectuer un pont entre la broche 2 ou 3
et cette en trée.
ENTREE EN TENSION
(Raccordement 7)
Entrée analogique de mesure de tension.
Con nec ter ici le conducteur du signal
analogique +. Dans le cas dʼune er reur de
branchement, le message “Err4” est
affiché.
Attention : Cette entrée est isolée
élec tri que ment afin dʼéviter les signaux
parasites vé hi cu lés par la ten sion
dʼali men ta tion. Il faut donc relier, pour la
me su re, le con duc teur du signal le plus
négatif à lʼentrée de masse ana lo gi que
de référence.
Notice de mise en service de
lʼafficheur di gi tal à entrées analogiques
E5324E Série
14 MN05401008E
3. Réglage des paramètres de
fonctionnement
3.1 Sélection de la valeur affichée et de
la re fi ni tion des valeurs maximum et
minimum
Le bouton-poussoir de droite permet la
commutation en tre lʼaffichage des valeurs
de la mesure instantanée, de la mesure
maximum et de la mesure minimum.
Une impulsion sur ce bouton fait appa-
raître pour une du rée de deux secondes
la fonction active (“Act”, “Min” ou “Max”).
Si, dans ces deux secondes, le bou ton de
droite est pressé encore une fois, la fonc-
tion active est modifiée. Cette modifica-
tion est confirmée par lʼaffichage de “Act”,
“Min” ou “Max”. Ensuite lʼap pa reil affiche
la valeur. Si “Min” ou “Max” est sé lec tion -
né, cette valeur peut être effacée à lʼaide
du bouton-poussoir de gauche. Si ni lʼen -
re gis tre ment de la valeur maximum, ni
celui de la valeur minimum ne sont ac ti -
vés, les touches ne sont pas actives
lorsque lʼappareil est en fonction.
3.2 Réglage des paramètres de lʼappareil
a. Presser les deux boutons-poussoirs de la
face avant et mettre lʼappareil sous tension.
b. Sur lʼaffichage apparaît le message :
c. Dès relâchement des boutons-poussoirs
apparaît, par périodes dʼune seconde, le titre
du menu et sa programmation actuelle.
Presser un bouton-poussoir pour nʼafficher à
lʼécran que le défilement des paramètres de
réglage.
d. Une impulsion sur le bouton-poussoir de
droite permet de passer à la valeur suivante
du paramètre en cours de réglage.
Pour introduire des valeurs numériques (par
exemple lors du réglage du facteur dʼéchelle),
sélectionner, à lʼaide du bouton-poussoir de
gauche, la décade, puis, à lʼaide du bouton de
droite, la valeur de celle-ci.
e. Passer au paramètre suivant du menu en
maintenant le bouton-poussoir de gauche
pressé et en actionnant celui de droite.
f. Le dernier paramètre de chaque menu de
réglage, ”EndPro”, permet, en sélectionnant
”Yes”, de quitter le menu de programmation
et de prendre en compte (sauvegarder) les
nouvelles valeurs. Si ”No” est sélectionné, la
programmation recommence depuis le début,
en conservant les dernières valeurs
introduites. Il est alors possible de les vérifier
ou de les modifier à nouveau.
4. Mode de programmation
Les paramètres réglables sont indiqués
ci-dessous, dans lʼordre de leur apparition
sur lʼaffichage. Lʼappareil est donc
entièrement programmé après un cycle
de pro gram ma tion.
La représentation supérieure de
lʼaffichage correspond toujours au
réglage effectué en usine.
4.1 Plage du signal dʼentrée
de 0 à 20 mA
de 4 à 20 mA
de 0 à 10 V
de 2 à 10 V
4.2 Affichage de la valeur maximum
La valeur maximum est
af fi chée
La valeur maximum
nʼest pas affichée et le
pa ra tre suivant est
ignoré.
MN05401008E 15
français
4.3 Redéfinition de la valeur maximum
La valeur maximum peut
être redéfinie à lʼaide du
bouton-poussoir rouge
(la valeur instantanée
devient la nouvelle valeur
maxi mum).
La valeur maximum ne
peut pas être redéfinie.
4.4 Affichage de la valeur minimum
La valeur minimum est
af fi chée
La valeur minimum nʼest
pas affichée et le pa ra -
tre suivant est ignoré.
4.5 Redéfinition de la valeur minimum
La valeur minimum peut
être redéfinie à lʼaide du
bou ton-poussoir rouge
(la valeur instantanée
devient la nou vel le valeur
mi ni mum).
La valeur minimum ne
peut pas être redéfinie.
4.6 Réglage du point décimal
0 pas de décimale
0.0 une décimale
0.00 deux décimales
0.000 trois décimales
0.0000 quatre décimales
Le point décimal détermine le
nom bre de décimales affichées.
4.7 Signal dʼentrée minimum
(uniquement dans la pla ge de mesure
de 4 à 20 mA ou de 2 à 10 V)
En fonction de la plage de
mesure sélectionnée, la
procédure a) ou b) est
effectuée.
a) Si le signal dʼen trée est
in rieur, dans la plage de
mesure de 4 à 20 mA, à
la valeur définie ici, le
mes sa ge “lo” est affiché.
b) Si le signal dʼen trée est
in rieur, dans la plage
de mesure de 2 à 10 V, à
la valeur définie ici, le
mes sa ge “lo” est affiché.
4.8 Valeur affichée dans le cas du
signal dʼentrée le plus bas
Une valeur entre -19999 et
99999 peut être affichée
lors de la détection du
signal dʼen trée le plus bas.
La pro gram ma tion du point
ci mal est respectée.
16 MN05401008E
4.10 Valeur affichée dans le cas du
signal dʼentrée le plus haut
Une valeur entre -19999
et 99999 peut être
affichée lors de la détec-
tion du signal dʼen trée le
plus haut. La pro gram ma -
tion du point dé ci mal est
res pec tée.
4.9 Signal dʼentrée maximum
(uniquement dans la plage de mesure
de 4 à 20 mA ou de 2 à 10 V)
Ce paramètre permet une limitation de
la plage dʼaf fi cha ge.
En fonction de la plage de
mesure sélectionnée, la
procédure a) ou b) est
effectuée
a) Si le signal dʼentrée est
su rieur, dans la plage
de mesure de 4 à 20 mA,
à la valeur définie ici, le
mes sa ge “hi” est affiché.
b) Si le signal dʼentrée est
su rieur, dans la plage
de mesure de 2 à 10 V, à
la valeur définie ici, le
mes sa ge “hi” est affiché.
4.11 Fin de la programmation
La programmation est
exécutée encore une
fois. Les valeurs intro-
duites peuvent être
vérifiées et modifiées.
La programmation est
terminée et les valeurs
introduites sont prises
en compte comme
nouveaux paramètres.
Lʼappareil est alors prêt
à fonctionner.
5. Raccordement
1 10 – 30 V DC
2GND
3GND
4LATCH
5 0 (4) – 20 mA DC
6 Analog GND
7 0 (2) – 10 V DC
6. Caracteristiques techniques
Affichage : 5 chiffres - LED à 7
segments, hauteur 8 mm
Plages de mesure :
0 .. 10 V DC
2 .. 10 V DC
0 .. 20 mA DC
4 .. 20 mA DC
Résolution : 14 bits
Précision : < 0,1% ± 1 chiffre à
température am bian te de
20°C
Ajuste de zéro : automatique
Dérive due à la
température : <70 ppm/K
Vitesse de mesure :
0,5 ... 2 mesures/sec
Mesure en courant :
Chute de tension 2,0 V DC
maximum avec 20 mA
Courant max. : 50 mA
MN05401008E 17
français
Mesure en tension :
Résistance dʼentrée >1 MΩ
Tension dʼentrée
maximum 30 V
Suppression du ronflement du secteur :
Filtrage numérique 50 Hz
Tension dʼalimentation :
10 .. 30 V DC,
isolation galvanique
Consommation : max. 50 mA
Température dʼutilisation :
-10°C ... +50°C
Température de stockage :
-25°C ... +70°C
Mémorisation des paramètres :
EEPROM (capacité : 1x10
6
cycles
dʼenregistrement ou 10 ans)
Poids : 50 g environ
Indice de protection :
IP 65 (par lʼavant)
Immunité aux parasites :
EN 61 000-4-2; EN 55011 Classe B;
EN 61 000-6-2
Nettoyage :
Les faces avant des appareils ne doivent
être nettoyées quʼavec un chiffon doux
humide.
Messages d'erreur
Err 0* Erreur dans partie A/D
Err 3* Erreur dans EEPROM
Err 4** signal d'entrée
analogue au-dessus
de lag plage de
mesure
Err 5* Erreur dans la
EEPROM.
appareil non calibré
* Merci de nous envoyer lʼappareil pour
vérification.
** Vérifiez le signal d'entrée et la
programmation
7. La livraison comprend
– Afficheur digital
– Etrier
Cadre pour montage par vis découpe
dʼencastrement 50 x 25 mm
Cadre pour montage par étrier découpe
dʼencastrement 50 x 25 mm
– Joint
1 feuille de symboles autocollants
8. Exemples
8.1 Mesure de température
Un capteur de température à caractéris-
tiques li néai res (dans le cas de capteurs
non linéaires, il faut intercaler des élé-
ments de li néa ri sa tion) délivre 2 V à 0°C
et 8 V à 80°C. La plage de mesure sé lec -
tion née sera celle de 0 à 10 V. 2 V est la
valeur la plus petite à mesurer. Il est
maintenant possible dʼat tri buer la valeur
dʼaffichage 0 à cette valeur. De même, la
valeur la plus grande à me su rer est 8 V, à
laquelle sera attribuée la valeur dʼaf fi cha -
ge 80. Lʼaffichage est maintenant réglé en
fonc tion du capteur, et peut af fi cher toutes
les va leurs intermédiaires.
Las valeurs affichées
peuvent être déplacées
librement dans la plage
dʼaffichage
18 MN05401008E
8.2 Indication de niveau
Un capteur de niveau à caractéristiques
linéaires (dans le cas de capteurs non
linéaires il faut in ter ca ler des élé ments de
linéarisation) délivre 5 mA si le réservoir
est vide et 19 mA sʼil est plein. Il doit
afficher 10 m
3
si le réservoir est plein et
0 m
3
sʼil est vide. La plage de me su re
sélectionnée sera celle de 4 à 20 mA.
5 mA est la valeur la plus petite à mesur-
er. Il est main te nant possible dʼattribuer la
valeur dʼaffichage 0 à cet te valeur. De
même, la valeur la plus grande à mesurer
est 19 mA, à laquelle sera attribuée la
valeur dʼaf fi cha ge 10. Lʼaffichage est
maintenant réglé en fonction du capteur,
et peut afficher toutes les va leurs in ter -
diai res.
8.3 Quantité prélevée
Au lieu dʼafficher la quantité restante, il
faut afficher la quantité prélevée.
La plage de mesure sélectionnée sera de
nouveau celle de 4 à 20 mA.
La plus petite valeur mesurée, 5 mA, se
verra at tri buer la valeur affichée 10, alors
que la valeur af fi chée 0 sera attribuée à
la plus grande valeur me su rée, 19 mA.
8.4 Indication de niveau avec indica-
tion de niveau minimum
Dans ce troisième cas, il faut également
afficher la quan ti té restante, le réservoir
ayant une contenance de 10 m
3
. Le vol-
ume de remplissage ne doit pas dé pas ser
8 m
3
, et le contenu du réservoir ne doit
pas descendre au-des sous de 1 m
3
. Il
faut donc afficher “hi” pour des valeurs
> 8 m
3
et “lo” pour des valeurs < 1 m
3
.
La plage de mesure sélectionnée sera
celle de 4 à 20 mA. La valeur dʼaffichage
0 sera attribuée à la plus petite valeur
dʼentrée, et la valeur dʼaffichage 10 sera
attribuée à la plus grande valeur dʼentrée.
En plus, le paramètre “Signal dʼentrée
minimum” se ver ra attribuer la valeur
mesurée correspondant à un con te nu
mesuré de 1 m
3
, p. ex. 5,6 mA, et le
pa ra tre “Si gnal dʼentrée maximum”
se verra attribuer la valeur me su rée
correspondant à un contenu mesuré de
8 m
3
, p. ex. 16,8 mA. De cette manière,
le mes sa ge “hi” sera affiché pour des
valeurs dʼentrée > 16,8 mA, et le mes sa -
ge “lo” sera affiché pour des valeurs
dʼentrée < 5,6 mA.
La tension maxi-
mum en entrée
ou le courant
maximum en
entrée peu vent
être déplacés
librement dans
les pla ges dʼaf-
fichage de la
ten sion dʼentrée
ou du cou rant
dʼentrée.
La tension
maximum en
entrée ou
le courant
maximum
en entrée
peu vent être
déplacés
librement dans
les pla ges
dʼaffichage
de la ten sion
dʼentrée ou du
cou rant
dʼentrée.
Las valeurs affichées peuvent
être déplacées librement dans la
plage dʼaffichage.
MN05401008E 19
deutsch
1. Beschreibung
5stellige Digitalanzeige mit Analogeingängen
gut ablesbare, hell leuchtende 8 mm hohe
LED-Anzeige
Anzeigebereich von -19999 bis 99 999 mit
Vornullenunterdrückung.
Die Programmierung der Funktionen, bzw.
Betriebsparameter erfolgt über die beiden
Einstelltasten. Be die ner füh rung auf dem
Display während der Programmierroutine.
Programmierbar sind:
Messbereich
Maximalwertanzeige ja/nein
Maximalwertrücksetzung ja/nein
Minimalwertanzeige ja/nein
Minimalwertrücksetzung ja/nein
Dezimalpunkt
Minimales Eingangssignal
Anzuzeigender Wert bei kleinstem Eingangs-
signal
Maximales Ein gangs si gnal
Anzuzeigender Wert bei höchstem Eingangs-
signal
2. Eingänge
LATCH (Anschluss 4)
Statischer Speichereingang für
Anzeigestop. Bei Ak ti vie rung (pnp) mit
Eingangssignal 4 ... 30 V DC wird der
momentane Messwert in der Anzeige fest-
gehalten, bis dieser Eingang wieder
freigegeben, oder sein Si gnal pe gel
unter 2 V DC absinkt. Ermittlung von
Minimal- und Ma xi mal wert läuft im
Hintergrund weiter.
STROMEINGANG (Anschluss 5)
Analoger Strommesseingang mit
Verpolungsschutz und Strombegrenzung
auf max. 50 mA. Die Signalleitung mit
dem analogen +-Signal ist hier
anzuschließen.
Achtung: Zur Vermeidung von
Störsignalen, die von der
Spannungsversorgung herrühren ist
dieser Eingang galvanisch getrennt. Für
eine Messung ist daher die negativere
Signalleitung mit dem analogen Be zugs -
mas sen ein gang zu verbinden.
ANALOG GND (Anschluss 6)
Analoger Bezugseingang
Soll keine galvanische Trennung
zwischen Messkreis und
Versorgungsspannung notwendig sein, so
ist eine Verbindung zwischen Pin 2 oder 3
und diesem An schluss herzustellen.
SPANNUNGSEINGANG (Anschluss 7)
Analoger Spannungsmesseingang. Die
Signalleitung mit dem analogen +-Signal
ist hier anzuschließen. Bei Ver po lung
erscheint im Display „Err4“.
Achtung: Zur Vermeidung von
Störsignalen, die von der
Spannungsversorgung herrühren, ist
dieser Eingang galvanisch getrennt. Für
eine Messung ist daher die negativere
Signalleitung mit dem analogen
Be zugs mas sen ein gang zu verbinden.
Bedienungsanleitung
Digitalanzeige mit Analogeingängen
E5324E Serie
20 MN05401008E
3. Einstellung der
Betriebsparameter
3.1 Auswahl des angezeigten Wertes
und Rücksetzung von Maximal, bzw.
Minimalwert
Durch Drücken der rechten Taste kann
zwischen der An zei ge des aktuellen
Messwertes, des Maximal- und des
Minimalwertes umgeschaltet werden.
Durch einmaliges Betätigen wird für 2
Sekunden die aktuelle Funktion („Act“ ,
„Min“ oder „Max“) angezeigt. Wird inner-
halb dieser Zeit die rechte Taste ein
zweites mal gedrückt, so wird die aktuelle
Funktion gewechselt und zur Bestätigung
für ca. 2 Sekunden „Act“, „Min“ oder
„Max“ angezeigt. Danach erfolgt die
Anzeige des Wertes. Ist „Min“ oder
„Max“ angewählt, so kann dieser Wert
durch Betätigen der linken Taste gelöscht
werden. Ist weder die Maximal- noch die
Mi ni mal wert spei che rung im Set-Up
aktiviert, sind die Tasten im Betrieb ohne
Funktion.
3.2 Einstellung der Geräteparameter
a. Beide Tasten auf der Vorderseite gedrückt
halten und Span nungs ver sor gung einschalten.
b. Auf dem Display erscheint
c. Sobald die Tasten losgelassen werden
er scheint im se künd li chen Wechsel der
Menütitel und die aktuelle Me punkt ein stel -
lung. Nach Betätigen einer Taste wird nur
noch die Me punkt ein stel lung angezeigt.
d. Durch Drücken der rechten Taste wird die
Me punkt ein stel lung jeweils um einen Wert
wei ter ge schal tet.
Wenn Zahlenwerte eingegeben werden sollen
(z.B. bei der Faktoreinstellung), wird mit der
linken Taste zunächst die Dekade an ge wählt
und dann mit der Rechten der Wert
ein ge stellt.
e. Umschalten auf den nächsten Menüpunkt
durch gedrückt halten der linken Taste und
Betätigen der rechten Taste.
f. Der jeweils letzte Menütitel ”EndPro” er mög -
licht durch An wahl von ”Yes” das Verlassen
des Programmiermenüs und die Über nah me
(Spei che rung) der neuen Werte. Wird ”No” an -
ge wählt, beginnt die Programmierroutine von
vorne, wobei die zuletzt eingestellten Werte
zunächst erhalten bleiben. Diese können nun
nochmals verändert oder kon trol liert werden.
4. Programmierroutine
Nachfolgend sind die einstellbaren
Parameter des Ge tes aufgeführt, die in
der unten angegebenen Rei hen fol ge
eingestellt werden können. Nach einem
Durchlauf der Routine ist somit das Gerät
vollständig pro gram miert.
Die jeweils obere Darstellung entspricht
der Werkseinstellung.
4.1 Eingangssignalbereich
4.2 Maximalwertanzeige
Maximalwert
wird an ge zeigt
Maximalwertanzeige wird
unterdrückt und nächster
Menütitel übersprungen
0..20 mA
4..20 mA
0..10 V
2..10 V
MN05401008E 21
deutsch
4.3 Maximalwertrücksetzung
Maximalwert kann mit
roter Taste zurückgesetzt
werden (aktueller Mess -
wert wird neuer
Maximalwert)
Maximalwert kann nicht
zu rück ge setzt werden
4.4 Minimalwertanzeige
Minimalwert wird
angezeigt
Minimalwertanzeige wird
unterdrückt und nächster
Menütitel übersprungen
4.5 Minimalwertrücksetzung
Minimalmalwert kann
mit roter Taste
zurückgesetzt werden
(aktueller Mess wert
wird neuer Mi ni mal wert)
Minimalwert kann nicht
zu rück ge setzt werden
4.6 Dezimalpunkteinstellung
0 keine Dezimalstelle
0.0 eine Dezimalstelle
0.00 zwei Dezimalstellen
0.000 drei Dezimalstellen
0.0000 vier Dezimalstellen
Der Dezimalpunkt legt die
Anzahl der angezeigten
Nach kom ma stel len fest.
4.7 Minimales Eingangssignal (nur bei
Messbereich 4..20 mA oder 2..10 V)
Dieser Menüpunkt ermöglicht eine
Einschränkung des Anzeigebereichs. (siehe auch
4.9)
Je nach eingestelltem
Messbe reich wird a) oder b)
durchlaufen
4.8 Anzeigewert bei niedrigstem
Eingangssignal
Dem niedrigsten Ein -
gangs si gnal kann ein
an zu zei gen der Wert
zwi schen -19999 und
99999 zugeordnet werden.
Die Einstellung des
De zi mal punk tes wird
be rück sich tigt.
a) Unterschreitet das Ein -
gangs si gnal bei Messbe -
reich 4..20 mA den hier
eingestellten Wert wird „lo“
angezeigt.
b) Unterschreitet das Ein -
gangs si gnal bei Messbe -
reich 2..10 V den hier
eingestellten Wert wird „lo“
angezeigt.
4.11 Ende der Programmierung
Programmierroutine wird
noch einmal durchlaufen.
Bisher eingestellte Werte
können überprüft und
ge än dert werden.
Programmierroutine wird
beendet und alle einge-
stellten Werte werden als
neue Parameter über-
nommen. Das Gerät
ist anschliessend
betriebs-bereit.
4.10 Anzeigewert bei höchstem
Eingangssignal
Dem höchsten Eingangs-
signal kann ein anzu-
zeigender Wert zwischen
-19999 und 99999
zu-geordnet werden.
Die Einstellung des
Dezi-malpunktes wird
berück-sichtigt.
4.9 Maximales Eingangssignal (nur bei
Messbereich 4..20 mA oder 2..10 V)
Dieser Menüpunkt ermöglicht eine
Einschränkung des Anzeigebereichs.
Je nach eingestelltem
Messbe reich wird a) oder b)
durchlaufen
5. Anschlussbelegung
1 10 – 30 VDC
2GND
3GND
4LATCH
5 0 (4) – 20 mA DC
6 Analog GND
7 0 (2) – 10 V DC
6. Technische Daten
Anzeige: 5-stellige rote 7-Segment
LED-Anzeige, 8 mm
hohe Ziffern
Messbereiche: 0 .. 10 V DC
2 .. 10 V DC
0 .. 20 mA DC
4 .. 20 mA DC
Auflösung: 14 Bit
Genauigkeit: < 0,1% ± 1 Digit über den
gesamten Messbereich
bei 20°C
Umgebungstemperatur
Nullabgleich: automatisch
Temperaturdrift: < 70ppm/K
Messgeschwindigkeit:
0,5 ... 2 Messungen/sec
Strommessung:
Spannungsabfall
max. 2,0 V bei 20 mA
Max. Strom: 50 mA
Spannungsmessung:
Eingangswiderstand >1 MΩ
Max. Spannung 30 V
Netzbrummunterdrückung:
digitale Filterung 50 Hz
Spannungsversorgung:
10 .. 30 V DC, galvanisch
getrennt
Stromaufnahme: max. 50 mA
Umgebungstemperatur:
-10°C ... +50°C
22 MN05401008E
a) Überschreitet das Ein -
gangs si gnal bei Messbe -
reich 4..20 mA den hier
eingestellten Wert wird „hi“
angezeigt.
b) Überschreitet das Ein -
gangs si gnal bei Messbe -
reich 2..10 V den hier
eingestellten Wert wird „hi“
angezeigt.
Lagertemperatur: -25°C ... +70°C
Datensicherung: EEPROM 1 Million
Speicherzyklen
oder 10 Jahre
Gewicht: ca. 50 g
Schutzart: IP 65 (von vorne)
EMV:
Störabstrahlung EN 61 000-4-2/
EN 55011 Klasse B
Störfestigkeit EN61000-6-2
Reinigung:
Die Frontseite des Gerätes darf nur mit
einem weichen, mit Wasser ange-
feuchteten Tuch gereinigt werden.
Fehlermeldungen:
Err 0* Fehler/Defekt im A/D-Teil
Err 3* Fehler/Defekt beim
EEPROM
Err 4** Analoges Eingangssignal
überschreitet den gülti-
gen Messbereich
Err 5* Fehler/Defekt beim
EEPROM. Gerät nicht
abgegelichen
* Bitte Gerät zur Überprüfung einschicken
** Eingangssignal und Programmierung
überprüfen
7. Lieferumfang:
– Digitalanzeige
– Spannbügel
– Frontrahmen für Schraubbefestigung
Einbauquerschnitt 50x25 mm
– Frontrahmen für
Spannbügelbefestigung
Einbauquerschnitt 50x25 mm
– Dichtung
– 1 Blatt selbstklebende Symbole
8. Beispiele:
8.1 Temperaturmessung
Ein Temperatursensor mit linearer
Charakteristik (unlinearen Sensoren sind
Li nea ri sier glie der vor zu schal ten) liefert bei
-10 °C 0 V und bei 80 °C 10 V.
Als Messbereich wird 0..10 V gewählt.
0 V ist der kleinstmögliche Messwert.
Diesem Mess wert kann nun der
Anzeigewert -10 zugeordnet wer den,
entsprechend ist 10 V der größte
Messwert. Die sem wird der Anzeigewert
80 zugeordnet. Die An zei ge ist nun auf
den Sensor abgestimmt und kann die
je wei li gen Zwischenwerte anzeigen.
Anzeigewert innerhalb
des Anzeigebereichs
frei verschiebbar
deutsch
MN05401008E 23
8.2 Füllstandsmessung
Ein Füllstandssensor mit linearer
Charakteristik (unlinearen Sensoren sind
Linearisierglieder vor zu schal ten) liefert bei
leerem Behälter 5 mA und bei vollem
19 mA. Es soll bei vollem Behälter 10 m
3
und bei leerem Behälter 0 m
3
angezeigt
werden. Als Messbereich wird 4..20 mA
gewählt.
5 mA ist der kleinstmögliche Messwert.
Diesem Mess wert kann nun der
Anzeigewert 0 zugeordnet werden,
entsprechend ist 19 mA der größte Meß -
wert. Diesem wird der Anzeigewert 10
zugeordnet. Die Anzeige ist nun auf den
Sensor abgestimmt und kann die jeweili-
gen Zwischenwerte anzeigen.
8.3 Entnommene Menge
Es soll statt der Füllmenge, die ent-
nommene Men ge angezeigt werden.
Als Messbereich wird wiederum 4..20 mA
gewählt. Dem kleinsten Messwert von
5 mA wird nun ein Anzeigewert von 10
und dem größten Messwert von 19 mA
ein Anzeigewert von 0 zugeordnet.
8.4 Füllstandsmeßung mit
Grenzwertanzeige
In einem dritten Fall soll wiederum die
vorhandene Menge angezeigt werden,
wobei der Behälter 10 m
3
Volumen
besitzt, aber maximal 8 m
3
eingefüllt wer -
den sollen, weiterhin soll der Inhalt nicht
unter 1 m
3
absinken. Somit soll bei
Werten > 8 m
3
„hi“ und bei Werten
< 1 m
3
„lo“ angezeigt werden.
Als Messbereich wird 4..20 mA aus-
gewählt. Dem kleinsten Eingangswert
wird der Anzeigewert 0, dem größten
Eingangswert wird 10 zugeordnet.
Zusätzlich wird nun im Menüpunkt
„Minimales Ein gangs si gnal“ der Meßwert
eingestellt, der einem Inhalt von 1 m
3
entspricht, z.B. 5,6 mA und im Me punkt
„Maximales Eingangssignal“ der
Messwert eingestellt, der dem Inhalt
8 m
3
, z.B. 16,8 mA ent spricht. Somit wird
bei Eingangswerten > 16,8 mA „hi“ und
< 5,6 mA „lo“ angezeigt.
Minimale
Eingans-
spannung,
bzw. minimaler
Ein-
gangsstrom
in ner halb des
Eingangsspann
ungs-bereichs,
bzw.
Eingangsstrom
-bereichs frei
verschiebbar.
Maximale
Eingans-spannung,
bzw. ma xi ma ler
Eingangsstrom
in ner halb des
Eingangs-
spannungs-
bereichs, bzw.
Eingangsstrom-
bereichs frei
ver schieb bar.
Anzeigewert innerhalb
des Anzeigebereichs frei
verschiebbar
24 MN05401008E
© 2007 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. MN05401008E/CPG
March 2007
Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN CARE (877-386-2273)
Eaton.com

Transcripción de documentos

english Operating instructions Digital display with analog inputs E5324E Series 2. Inputs LATCH (Connect 4) Static input to freeze the displayed value. If this input (pnp) is supplied with 4 – 30V DC, the actual value is frozen until the input is released or the signal level gets below 2V DC. The calculating of max. and min. value is not affected. CAUTION: To prevent interfering signals caused by the supply voltage, this input is isolated from the supply voltage. Connect the signal line with the - Signal to the analog reference input. français ANALOG GND (Connect 6) If no isolation between measuring circuit and supply voltage is necessary, connect pin 2 or 3 to this input. VOLTAGE INPUT (Connect 7) deutsch • 5 digit digital display with analog inputs • LED-Display with 8 mm [0.31 in] high characters and very high luminosity • Display range -19999 – 99999 with leading zero blanking • Programming of functions and operating parameters via the setting keys. During programming the display guides the user with text prompts. • Programmable features: Range Max. value display yes/no Max. value reset yes/no Min. value display yes/no Min. value reset yes/no Decimal point Min. input signal Displayed value at min. input signal Max. input signal Displayed value at max. input signal Analog voltage input. Connect the signal line with the analog + signal with this input. In case of reverse connection, the display shows “Err4”. CAUTION: To prevent interfering signals caused by the supply voltage, this input is isolated from the supply voltage. Connect the signal line with the - Signal to the analog reference input. CURRENT INPUT (Connect 5) Analog current input with reverse connection protection and current limitation to max. 50 mA. Connect the signal line with the analog + signal with this input. MN05401008E español 1. Description 1 3. Setting of the parameters 4. Programming routine 3.1 Selecting the displayed value Programmable parameters are shown in succession. After one pass, the device is fully programmed. In each case the first shown item is the factory preset. By pressing the right key, the display can be switched between the current, min., or max. value. Press the right key once to display the current function (“Act”, “Min” or “Max”) for 2 seconds. If within this period the right key is pressed again, the current function is changed. The display shows the new current function for two seconds. Afterwards the corresponding value is displayed. If “Min” or “Max” is the current function, the value can be reset by pressing the left key. If neither storing of min. nor max. value is activated in setup, both keys are out of function. 4.1 Range of input signal 0 – 20 mA 4 – 20 mA 0 – 10V 2 – 10V 4.2 Max. value display 3. 2 Setting the operating parameters a. Hold down both keys on front panel and switch on the supply voltage. b. The display shows: Max. value can be displayed Max. value wonʼt be displayed, next menu title is skipped c. After releasing the keys the display alternates between menu title and corresponding menu item at a frequency of 0.5 Hz. After any key is pressed, only the menu item is displayed. d. Press the right key to switch the menu item to next value. e. Hold down the left key and press the right key to switch to the next menu title. f. After programming the last menu item, the programming routine will be exited and the new values will be stored by switching the menu item to “YES”. If you choose “NO”, the programming routine will be passed through once again. 4.3 Max. value reset Max. value can be reset by pressing left button. (Current value becomes new max. value) Max. value canʼt be reset. 4.4 Min. value display Min. value can be displayed Min. value wonʼt be displayed, next menu title is skipped 2 MN05401008E 4.8 Displayed value at min. input signal A corresponding display value between -19999 and 99999 can be assigned to the lowest input signal. The decimal pointʼs position is considered. Min. value can be reset by pressing left button. (Current value becomes new min. value) Min. value canʼt be reset. 4.6 Decimal point The decimal point indicates the number of decimal places. 0 0.0 0.00 0.000 0.0000 no decimal place one decimal place two decimal places three decimal places four decimal places 4.9 Max. input signal (only if input signal range is 4 – 20 mA or 2 – 10V) This menu title allows a limitation of the display range. Depending on chosen input range a) or b) is selected. a) If the input signal level at input range 4 – 20 mA goes above this value, the display shows “high”. b) If the input signal level at input range 2 – 10V goes above this value, the display shows “high”. 4.7 Min. input signal (only if input signal range is 4 – 20 mA or 2 – 10V) This menu title allows a limitation of the display range (see 4.9). Depending on chosen input range a) or b) is selected. a) b) MN05401008E If the input signal level at input range 4 – 20 mA goes below this value, the display shows “lo”. If the input signal level at input range 2 – 10V goes below this value, the display shows “lo”. 4.10 Displayed value at max. input signal A corresponding display value between -19999 and 99999 can be assigned to the highest input signal. The decimal pointʼs position is considered. 3 english 4.5 Min. value reset 4.11 End of programming Programming routine will be passed through once again. All parameters can be checked. Programming routine will be exited and the new parameters will be stored. Afterwards the device is ready to use. 5. Connections 1 2 3 4 5 6 7 10 – 30V DC GND GND LATCH 0 (4) – 20 mA Analog GND 0 (2) – 10V DC 6. Technical data Display: 5 digit 7 segment red LED-Display, 8 mm [0.31 in.] high characters Range of input signals 0 – 10V DC 2 – 10V DC 0 – 20 mA DC 4 – 20 mA DC Resolution: 14 Bit Linearity: < 0.1% ± 1 digit at an ambient temperature of 20°C [68°F] Zero adjustment: automatic Temperature drift: <70ppm/K Measuring rate: 0.5 – 2 Measurement/sec Current measuring: Voltage drop: max. 2.0V at 20 mA Current limitation: 50 mA 4 Voltage measurement: Input resistance: >1 MΩ Elimination of power line hum: digital filter at 50 Hz Supply voltage: 10 – 30V DC, galvanically isolated Current consumption: max. 50 mA Ambient temperature: -10°C to 50°C [14 to 122°F] Storage temperature: -25°C to 70°C [-9 to 158°F] Data retention: via EEPROM 1 Million memory cycles or 10 years Weight: ca. 50 g [1.76 oz.] Front panel rating: IP 65 EMC: EN 61000-4-2/EN 55011 Class B EN 61000-6-2 Cleaning: The front of the unit is only to be cleaned with a soft cloth moistened with water. Error messages: Err 0* Error/defect in A/D-part Err 3* Error/defect EEPROM Err 4** Analog input overflow Err 5* Error/defect EEPROM. Device not calibrated * Please send the device back for checking ** Please check input signal and programming 7. Contents: - Digital display with analog inputs - Panel mounting clip - Bezel for screw mount, panel cut-out 50x25 mm [1.97 x 0.98 in.] - Bezel for clip mount, panel cut-out 50x25 mm [1.97 x 0.98 in.] - Sealing - Tack dry symbols MN05401008E 8. Examples: Displayed value can be freely adjusted to the input value inside the display range. MN05401008E 8.2 Level measurement A level sensor with linear characteristic (non-linear sensors haveto be linearized) supplies 19 mA at full tank and 5 mA at empty tank. If the tank is filled up, 10 m3 english 8.1 Temperature measurement A temperature sensor with linear characteristic (non-linear sensors, e.g. thermocouples need to be linearized) supplies 0V at -10°C [14°F] and 10V at 80°C [176°F]. 0 – 10V is chosen as input range. Assign -10 as “displayed value at min. input signal” to the lowest input level (0V) and 80 as “displayed value at max. input signal” (10V). The device is now tuned to the sensor, and measurement values and their corresponding display values in between are calculated. should be displayed and if the tank is empty 0 m3 should be displayed. 4 – 20 mA is chosen as input range. Assign 0 as “displayed value at min. input signal” to the lowest input level (5 mA) and 10 as “displayed value at max. input signal” (19 mA). The device is now tuned to the sensor, and measurement values and their corresponding display values in between are calculated. 8.3 Drawn quantity Instead of the level, the drawn quantity should be displayed. Again 4 – 20 mA is chosen as input range. Assign 10 as “displayed value at min. input signal” to the lowest input level (5 mA) and 0 as “displayed value at max. input signal” (19 mA). 5 8.4 Level measurement with limited display range A third example is level measurement with limited display range, that means a tank with 10 m3 has to be filled up at most to 8 m3 and its the level should not decrease below 1 m3. At values > 8 m3 the display shows “hi” and at values < 1 m3 the display shows “lo”. 4 – 20 mA is chosen as input range. Assign 0 as “displayed value at min. input signal” to the lowest input level and 10 as “displayed value at max. input signal” to the highest input level. Additionally at menu title “min. input signal” the value which corresponds to the 1 m3 level, e.g. 5.6 mA is programmed. Do the same with the value which corresponds to the 8 m3 level, e.g. 16.8 mA. At input levels > 16.8 mA “hi” will be displayed and at input levels < 5.6 mA “lo”. Max. input voltage or max. input current can be shifted inside the input voltage range or the input current range. Min. input voltage or min. input current can be shifted inside the input voltage range or the input current range. Displayed value can be freely adjusted to the input value inside the display range. 6 MN05401008E Instrucciones de operación Pantalla digital con entradas analógicas Serie E5324E 1. Descripción 2. Entradas RETENCIÓN (conexión 4) Entrada estática para congelar el valor que se muestra. Si a esta entrada (pnp) se le proporciona 4 – 30 V CC, el valor real se congela hasta que se libera la entrada o el nivel de la señal baja a menos de 2 V CC. No se ve afectado el cálculo de los valores máximos y mínimos. PRECAUCIÓN: Para evitar las señales perturbadoras que produce el voltaje de suministro, esta entrada se aísla del voltaje de suministro. Conecte la línea de señal con la señal analógica - a la entrada de referencia analógica. español • Pantalla digital de 5 dígitos con entradas analógicas • Pantalla LED con caracteres de 8 mm [0,31 pulg.] de altura y de gran luminosidad • Rango de pantalla de -19999 a 99999 con supresión de cero inicial • Programación de funciones y parámetros de operación por medio de las teclas de configuración. Durante la programación, la pantalla guía al usuario con indicaciones de texto. • Funciones programables: Rango Mostrar valor máx. sí/no Restablecer valor máx. sí/no Mostrar valor mín. sí/no Restablecer valor mín. sí/no Punto decimal Señal de entrada mín. Valor mostrado en señal de entrada mín. Señal de entrada máx. Valor mostrado en señal de entrada máx. CONEXIÓN A TIERRA ANALÓGICA (conexión 6) Si no es necesario usar aislamiento entre el circuito de medición y el voltaje de suministro, conecte la clavija 2 ó 3 a esta entrada. ENTRADA DE VOLTAJE (conexión 7) Entrada de voltaje analógica. Conecte la línea de señal con la señal analógica + a esta entrada. En caso de que haya una conexión inversa, la pantalla muestra “Err4”. PRECAUCIÓN: Para evitar las señales perturbadoras que produce el voltaje de suministro, esta entrada se aísla del voltaje de suministro. Conecte la línea de señal con la señal analógica - a la entrada de referencia analógica. ENTRADA DE CORRIENTE (conexión 5) Entrada de corriente analógica con protección de conexión inversa y límite de corriente en un máximo de 50 mA. Conecte la línea de señal con la señal analógica + a esta entrada. MN05401008E 7 3. Configuración de los parámetros 3.1 Selección del valor que se muestra Al presionar la tecla derecha, la pantalla puede cambiar entre el valor de corriente mínimo o máximo. Presione una vez la tecla derecha para mostrar la función de corriente (“Act”, “Min” o “Max”) durante 2 segundos. Si dentro de este período se vuelve a presionar la tecla derecha, cambia la función de corriente. La pantalla muestra la nueva función de corriente durante dos segundos. Luego, se muestra el valor correspondiente. Si “Min” o “Max” es la función de corriente, el valor se puede restablecer presionando la tecla izquierda. Si no está activado el almacenamiento del valor mínimo o máximo en la configuración, ambas teclas están fuera de función. 3. 2 Configuración de los parámetros de operación a. Mantenga presionadas ambas teclas del panel delantero y encienda el voltaje de suministro. b. La pantalla muestra: c. Luego de soltar las teclas, la pantalla alterna entre el título del menú y el elemento del menú correspondiente en una frecuencia de 0,5 Hz. Después de que se presione cualquier tecla, sólo se muestra el elemento del menú. d. Presione la tecla derecha para cambiar el elemento del menú al valor siguiente. e. Mantenga presionada la tecla izquierda y presione la tecla derecha para cambiar al siguiente título de menú. f. Después de programar el último elemento de menú, se cerrará la rutina de programación y se almacenarán los nuevos valores cambiando el elemento de menú a “YES”. Si escoge “NO”, la rutina de programación se iniciará una vez más. 8 4. Rutina de programación Los parámetros programables se muestran en secuencia. Después de una pasada, el dispositivo está completamente programado. En cada caso, el primer elemento que se muestra es el valor preconfigurado en fábrica. 4.1 Rango de la señal de entrada 0 – 20 mA 4 – 20 mA 0 – 10 V 2 – 10 V 4.2 Mostrar valor máximo Se puede mostrar el valor máximo No se mostrará el valor máximo, se omite el siguiente título de menú 4.3 Restablecer valor máximo Se puede restablecer el valor máximo presionando el botón izquierdo. (El valor de corriente se convierte en el nuevo valor máximo) No se puede restablecer el valor máximo. 4.4 Mostrar valor mínimo Se puede mostrar el valor mínimo No se mostrará el valor mínimo, se omite el siguiente título de menú MN05401008E 4.8 Valor mostrado en señal de entrada mínima Se puede restablecer el valor mínimo presionando el botón izquierdo. (El valor de corriente se convierte en el nuevo valor mínimo) Se puede asignar un valor de pantalla correspondiente entre -19999 y 99999 a la señal de entrada más baja. Se considera la posición del punto decimal. No se puede restablecer el valor mínimo. 4.6 Punto decimal El punto decimal indica el número de cifras decimales. 0 0.0 0.00 0.000 0.0000 ninguna cifra decimal una cifra decimal dos cifras decimales tres cifras decimales cuatro cifras decimales 4.7 Señal de entrada mínima (sólo si el rango de la señal de entrada es 4 – 20 mA ó 2 – 10 V) Este título de menú permite limitar el rango de pantalla (consulte 4.9). Dependiendo del rango de entrada que se escoja, se selecciona a) o b). a) b) MN05401008E Si el nivel de señal de entrada en el rango de entrada 4 – 20 mA es menor que este valor, la pantalla muestra “lo” (bajo). Si el nivel de señal de entrada en el rango de entrada 2 – 10 V es menor que este valor, la pantalla muestra “lo”. 4.9 Señal de entrada máxima (sólo si el rango de la señal de entrada es 4 – 20 mA ó 2 – 10 V) Este título de menú permite limitar el rango de pantalla. Dependiendo del rango de entrada que se escoja, se selecciona a) o b). a) Si el nivel de señal de entrada en el rango de entrada 4 – 20 mA supera este valor, la pantalla muestra “high” (alto). b) Si el nivel de señal de entrada en el rango de entrada 2 – 10 V supera este valor, la pantalla muestra “high”. 4.10 Valor mostrado en señal de entrada máxima Se puede asignar un valor de pantalla correspondiente entre -19999 y 99999 a la señal de entrada más alta. Se considera la posición del punto decimal. 9 español 4.5 Restablecer valor mínimo 4.11 Fin de la programación La rutina de programación se iniciará una vez más. Se pueden verificar todos los parámetros. Se cerrará la rutina de programación y se almacenarán los nuevos parámetros. Después de eso, el dispositivo está listo para su uso. 5. Conexiones 1 2 3 4 5 6 10 – 30 V CC CONEXIÓN A TIERRA CONEXIÓN A TIERRA RETENCIÓN 0 (4) – 20 mA Conexión a tierra analógica 7 0 (2) – 10 V CC 6. Datos técnicos Pantalla: Pantalla LED roja de 5 dígitos y 7 segmentos con caracteres de 8 mm [0,31 pulg.] de altura Rango de señales de entrada 0 – 10 V CC 2 – 10 V CC 0 – 20 mA CC 4 – 20 mA CC Resolución: 14 bits Linealidad: < 0,1% ± 1 dígito a temperatura ambiente de 20° C [68° F] Ajuste a cero: automático Deriva térmica: <70 ppm/K Velocidad de medición: 0,5 – 2 medición/seg. Medición de corriente: Caída de voltaje: 2,0 V a 20 mA como máximo Límite de corriente: 50 mA 10 Medición de voltaje: Resistencia de entrada: >1 MΩ Eliminación de zumbido de la línea de alimentación: Filtro digital a 50 Hz Voltaje de suministro: 10 – 30 V CC, aislado galvánicamente Consumo de corriente: 50 mA como máximo Temperatura ambiente: -10° C a 50° C [14° a 122° F] Temperatura de almacenamiento: -25° C a 70° C [-9 a 158° F] Retención de datos: Vía EEPROM 1 millón de ciclos de memoria o 10 años Peso: ca. 50 g [1,76 oz.] Clasificación del panel delantero: IP 65 EMC: EN 61000-4-2/EN 55011 Clase B EN 61000-6-2 Limpieza: La parte delantera de la unidad sólo se debe limpiar con un paño suave humedecido con agua. Mensajes de error: Err 0* Error/Defecto en la pieza A/D Err 3* Error/Defecto en la EEPROM Err 4** Exceso en la entrada analógica Err 5* Error/Defecto en la EEPROM. Dispositivo sin calibración * Envíe de vuelta el dispositivo para su revisión ** Verifique la señal de entrada y la programación MN05401008E 8. Ejemplos: 8.1 Medición de temperatura Un sensor de temperatura con característica lineal (sensores no lineales, por ej., los termopares se deben linearizar) suministra 0 V a -10° C [14° F] y 10 V a 80° C [176° F]. Se escoge 0 – 10 V como rango de entrada. Asigne -10 como “valor mostrado en señal de entrada mínima” al nivel de entrada más bajo (0 V) y 80 como “valor mostrado en señal de entrada máxima” (10 V). Ahora el dispositivo está sintonizado según el sensor, y se calculan los valores de medición y sus valores intermedios respectivos que se muestran. 8.2 Medición de nivel Un sensor de nivel con característica lineal (los sensores no lineales se deben linearizar) suministra 19 mA con tanque lleno y 5 mA con tanque vacío. Si el tanque está lleno, se debe mostrar 10 m3 y si el tanque está vacío, se debe mostrar 0 m3. Se escoge 4 – 20 mA como rango de entrada. Asigne 0 como “valor mostrado en señal de entrada mínima” al nivel de entrada más bajo (5 mA) y 10 como “valor mostrado en señal de entrada máxima” (19 mA). Ahora el dispositivo está sintonizado según el sensor, y se calculan sus valores intermedios y los valores de medición respectivos que se muestran. 8.3 Cantidad extraída En lugar del nivel, se debe mostrar la cantidad extraída. Nuevamente, se escoge 4 – 20 mA como rango de entrada. Asigne 10 como “valor mostrado en señal de entrada mínima” al nivel de entrada más bajo (5 mA) y 0 como “valor mostrado en señal de entrada máxima” (19 mA). El valor que se muestra se puede ajustar libremente en el valor de entrada dentro del rango de pantalla. MN05401008E 11 español 7. Contenido: - Pantalla digital con entradas analógicas - Abrazadera de montaje del panel - Bisel para montaje con tornillos, plantilla de recorte del panel de 50 x 25 mm [1,97 x 0,98] - Bisel para montaje con abrazadera, plantilla de recorte del panel de 50 x 25 mm [1,97 x 0,98] - Sellado - Símbolos adhesivos en seco 8.4 Medición de nivel con rango de pantalla limitado Un tercer ejemplo es la medición de nivel con rango de pantalla limitado, lo que significa que un tanque con 10 m3 se debe llenar como máximo en 8 m3 y su nivel no debe ser menor que 1 m3. En valores > 8 m3, la pantalla muestra “hi” y en valores < 1 m3, la pantalla muestra “lo”. Se escoge 4 – 20 mA como rango de entrada. Asigne 0 como “valor mostrado en señal de entrada mínima” al nivel de entrada más bajo y 10 como “valor mostrado en señal de entrada máxima” al nivel de entrada más alto. Adicionalmente, en el título de menú “min. input signal” (señal de entrada mín.) el valor que corresponde al nivel 1 m3, por ej., 5,6 mA se programa. Haga lo mismo con el valor que corresponda al nivel 8 m3, por ej., 16,8 mA. En niveles de entrada > 16,8 mA, se mostrará “hi” y en niveles de entrada < 5,6 mA, “lo”. El voltaje de entrada máximo o la corriente de entrada máxima se pueden cambiar dentro del rango de voltaje de entrada o del rango de corriente de entrada. El voltaje de entrada mínimo o la corriente de entrada mínima se pueden cambiar dentro del rango de voltaje de entrada o del rango de corriente de entrada. El valor que se muestra se puede ajustar libremente en el valor de entrada dentro del rango de pantalla. 12 MN05401008E Notice de mise en service de lʼafficheur digital à entrées analogiques 1. Description • • • • • Affichage digital à 5 chiffres avec entrées analogiques Affichage par LED hauteur 8 mm à haute luminosité pour une lecture aisée. Plage dʼaffichage de -19999 à 99 999 avec suppression des zéros non significatifs Programmation des paramètres de fonctionnement à lʼaide des deux boutons-poussoirs. Lʼaffichage indique en abrégé les différents paramètres. Peuvent être programmés : La plage de mesure Lʼaffichage de la valeur maximum oui/non La redéfinition de la valeur maximum oui/non Lʼaffichage de la valeur minimum oui/non La redéfinition de la valeur minimum oui/non Le point décimal Le signal dʼentrée minimum La valeur à afficher dans le cas du signal dʼentrée le plus petit Le signal dʼentrée maximum La valeur à afficher dans le cas du signal dʼentrée le plus grand 2. Entrées ENTREE EN COURANT (Raccordement 5) Entrée analogique de mesure de courant avec protection contre lʼinversion de polarité et limitation du courant à 50 mA maximum. Connecter ici le conducteur du signal analogique +. Attention : Cette entrée est isolée électriquement afin dʼéviter les signaux parasites véhiculés par la tension dʼalimentation. Il faut donc relier, pour la mesure, le conducteur du signal le plus négatif à lʼentrée de masse analogique de référence. ANALOGIQUE GND (Raccordement 6) entrée de référence analogique Dans le cas où il nʼy a pas lieu dʼavoir une isolation galvanique entre la boucle de mesure et la tension dʼalimentation, effectuer un pont entre la broche 2 ou 3 et cette entrée. LATCH (Raccordement 4) Entrée statique de blocage dʼaffichage. Lors de son activation (pnp) par un signal de niveau 10 à 30 V DC ; la valeur de mesure instantanée est figée jusquʼà ce que cette entrée soit libérée ou que le niveau du signal descende en-dessous de 2 V DC. La détermination des valeurs minimum et maximum continue en arrière-plan. MN05401008E ENTREE EN TENSION (Raccordement 7) Entrée analogique de mesure de tension. Connecter ici le conducteur du signal analogique +. Dans le cas dʼune erreur de branchement, le message “Err4” est affiché. Attention : Cette entrée est isolée électriquement afin dʼéviter les signaux parasites véhiculés par la tension dʼalimentation. Il faut donc relier, pour la mesure, le conducteur du signal le plus négatif à lʼentrée de masse analogique de référence. 13 français E5324E Série 3. Réglage des paramètres de fonctionnement 3.1 Sélection de la valeur affichée et de la redéfinition des valeurs maximum et minimum Le bouton-poussoir de droite permet la commutation entre lʼaffichage des valeurs de la mesure instantanée, de la mesure maximum et de la mesure minimum. Une impulsion sur ce bouton fait apparaître pour une durée de deux secondes la fonction active (“Act”, “Min” ou “Max”). Si, dans ces deux secondes, le bouton de droite est pressé encore une fois, la fonction active est modifiée. Cette modification est confirmée par lʼaffichage de “Act”, “Min” ou “Max”. Ensuite lʼappareil affiche la valeur. Si “Min” ou “Max” est sélectionné, cette valeur peut être effacée à lʼaide du bouton-poussoir de gauche. Si ni lʼenregistrement de la valeur maximum, ni celui de la valeur minimum ne sont activés, les touches ne sont pas actives lorsque lʼappareil est en fonction. 3.2 Réglage des paramètres de lʼappareil a. Presser les deux boutons-poussoirs de la face avant et mettre lʼappareil sous tension. b. Sur lʼaffichage apparaît le message : c. Dès relâchement des boutons-poussoirs apparaît, par périodes dʼune seconde, le titre du menu et sa programmation actuelle. Presser un bouton-poussoir pour nʼafficher à lʼécran que le défilement des paramètres de réglage. d. Une impulsion sur le bouton-poussoir de droite permet de passer à la valeur suivante du paramètre en cours de réglage. Pour introduire des valeurs numériques (par exemple lors du réglage du facteur dʼéchelle), sélectionner, à lʼaide du bouton-poussoir de gauche, la décade, puis, à lʼaide du bouton de droite, la valeur de celle-ci. 14 e. Passer au paramètre suivant du menu en maintenant le bouton-poussoir de gauche pressé et en actionnant celui de droite. f. Le dernier paramètre de chaque menu de réglage, ”EndPro”, permet, en sélectionnant ”Yes”, de quitter le menu de programmation et de prendre en compte (sauvegarder) les nouvelles valeurs. Si ”No” est sélectionné, la programmation recommence depuis le début, en conservant les dernières valeurs introduites. Il est alors possible de les vérifier ou de les modifier à nouveau. 4. Mode de programmation Les paramètres réglables sont indiqués ci-dessous, dans lʼordre de leur apparition sur lʼaffichage. Lʼappareil est donc entièrement programmé après un cycle de programmation. La représentation supérieure de lʼaffichage correspond toujours au réglage effectué en usine. 4.1 Plage du signal dʼentrée de 0 à 20 mA de 4 à 20 mA de 0 à 10 V de 2 à 10 V 4.2 Affichage de la valeur maximum La valeur maximum est affichée La valeur maximum nʼest pas affichée et le paramètre suivant est ignoré. MN05401008E La valeur maximum peut être redéfinie à lʼaide du bouton-poussoir rouge (la valeur instantanée devient la nouvelle valeur maximum). 4.7 Signal dʼentrée minimum (uniquement dans la plage de mesure de 4 à 20 mA ou de 2 à 10 V) En fonction de la plage de mesure sélectionnée, la procédure a) ou b) est effectuée. a) Si le signal dʼentrée est inférieur, dans la plage de mesure de 4 à 20 mA, à la valeur définie ici, le message “lo” est affiché. b) Si le signal dʼentrée est inférieur, dans la plage de mesure de 2 à 10 V, à la valeur définie ici, le message “lo” est affiché. La valeur maximum ne peut pas être redéfinie. 4.4 Affichage de la valeur minimum La valeur minimum est affichée La valeur minimum nʼest pas affichée et le paramètre suivant est ignoré. 4.8 Valeur affichée dans le cas du signal dʼentrée le plus bas 4.5 Redéfinition de la valeur minimum La valeur minimum peut être redéfinie à lʼaide du bouton-poussoir rouge (la valeur instantanée devient la nouvelle valeur minimum). Une valeur entre -19999 et 99999 peut être affichée lors de la détection du signal dʼentrée le plus bas. La programmation du point décimal est respectée. La valeur minimum ne peut pas être redéfinie. 4.6 Réglage du point décimal Le point décimal détermine le nombre de décimales affichées. 0 0.0 0.00 0.000 0.0000 MN05401008E pas de décimale une décimale deux décimales trois décimales quatre décimales 15 français 4.3 Redéfinition de la valeur maximum 4.9 Signal dʼentrée maximum (uniquement dans la plage de mesure de 4 à 20 mA ou de 2 à 10 V) Ce paramètre permet une limitation de la plage dʼaffichage. 4.11 Fin de la programmation La programmation est exécutée encore une fois. Les valeurs introduites peuvent être vérifiées et modifiées. En fonction de la plage de mesure sélectionnée, la procédure a) ou b) est effectuée a) Si le signal dʼentrée est supérieur, dans la plage de mesure de 4 à 20 mA, à la valeur définie ici, le message “hi” est affiché. b) Si le signal dʼentrée est supérieur, dans la plage de mesure de 2 à 10 V, à la valeur définie ici, le message “hi” est affiché. La programmation est terminée et les valeurs introduites sont prises en compte comme nouveaux paramètres. Lʼappareil est alors prêt à fonctionner. 5. Raccordement 4.10 Valeur affichée dans le cas du signal dʼentrée le plus haut Une valeur entre -19999 et 99999 peut être affichée lors de la détection du signal dʼentrée le plus haut. La programmation du point décimal est respectée. 16 1 2 3 4 5 6 7 10 – 30 V DC GND GND LATCH 0 (4) – 20 mA DC Analog GND 0 (2) – 10 V DC 6. Caracteristiques techniques Affichage : 5 chiffres - LED à 7 segments, hauteur 8 mm Plages de mesure : 0 .. 10 V DC 2 .. 10 V DC 0 .. 20 mA DC 4 .. 20 mA DC Résolution : 14 bits Précision : < 0,1% ± 1 chiffre à température ambiante de 20°C Ajuste de zéro : automatique Dérive due à la température : <70 ppm/K Vitesse de mesure : 0,5 ... 2 mesures/sec Mesure en courant : Chute de tension 2,0 V DC maximum avec 20 mA Courant max. : 50 mA MN05401008E * Merci de nous envoyer lʼappareil pour vérification. ** Vérifiez le signal d'entrée et la programmation MN05401008E 7. La livraison comprend – Afficheur digital – Etrier – Cadre pour montage par vis découpe dʼencastrement 50 x 25 mm – Cadre pour montage par étrier découpe dʼencastrement 50 x 25 mm – Joint – 1 feuille de symboles autocollants 8. Exemples 8.1 Mesure de température Un capteur de température à caractéristiques linéaires (dans le cas de capteurs non linéaires, il faut intercaler des éléments de linéarisation) délivre 2 V à 0°C et 8 V à 80°C. La plage de mesure sélectionnée sera celle de 0 à 10 V. 2 V est la valeur la plus petite à mesurer. Il est maintenant possible dʼattribuer la valeur dʼaffichage 0 à cette valeur. De même, la valeur la plus grande à mesurer est 8 V, à laquelle sera attribuée la valeur dʼaffichage 80. Lʼaffichage est maintenant réglé en fonction du capteur, et peut afficher toutes les valeurs intermédiaires. Las valeurs affichées peuvent être déplacées librement dans la plage dʼaffichage 17 français Mesure en tension : Résistance dʼentrée >1 MΩ Tension dʼentrée maximum 30 V Suppression du ronflement du secteur : Filtrage numérique 50 Hz Tension dʼalimentation : 10 .. 30 V DC, isolation galvanique Consommation : max. 50 mA Température dʼutilisation : -10°C ... +50°C Température de stockage : -25°C ... +70°C Mémorisation des paramètres : EEPROM (capacité : 1x106 cycles dʼenregistrement ou 10 ans) Poids : 50 g environ Indice de protection : IP 65 (par lʼavant) Immunité aux parasites : EN 61 000-4-2; EN 55011 Classe B; EN 61 000-6-2 Nettoyage : Les faces avant des appareils ne doivent être nettoyées quʼavec un chiffon doux humide. Messages d'erreur Err 0* Erreur dans partie A/D Err 3* Erreur dans EEPROM Err 4** signal d'entrée analogue au-dessus de lag plage de mesure Err 5* Erreur dans la EEPROM. appareil non calibré 8.2 Indication de niveau Un capteur de niveau à caractéristiques linéaires (dans le cas de capteurs non linéaires il faut intercaler des éléments de linéarisation) délivre 5 mA si le réservoir est vide et 19 mA sʼil est plein. Il doit afficher 10 m3 si le réservoir est plein et 0 m3 sʼil est vide. La plage de mesure sélectionnée sera celle de 4 à 20 mA. 5 mA est la valeur la plus petite à mesurer. Il est maintenant possible dʼattribuer la valeur dʼaffichage 0 à cette valeur. De même, la valeur la plus grande à mesurer est 19 mA, à laquelle sera attribuée la valeur dʼaffichage 10. Lʼaffichage est maintenant réglé en fonction du capteur, et peut afficher toutes les valeurs intermédiaires. 8.3 Quantité prélevée Au lieu dʼafficher la quantité restante, il faut afficher la quantité prélevée. La plage de mesure sélectionnée sera de nouveau celle de 4 à 20 mA. La plus petite valeur mesurée, 5 mA, se verra attribuer la valeur affichée 10, alors que la valeur affichée 0 sera attribuée à la plus grande valeur mesurée, 19 mA. 8.4 Indication de niveau avec indication de niveau minimum Dans ce troisième cas, il faut également afficher la quantité restante, le réservoir ayant une contenance de 10 m3. Le volume de remplissage ne doit pas dépasser 8 m3, et le contenu du réservoir ne doit pas descendre au-dessous de 1 m3. Il faut donc afficher “hi” pour des valeurs > 8 m3 et “lo” pour des valeurs < 1 m3. La plage de mesure sélectionnée sera celle de 4 à 20 mA. La valeur dʼaffichage 0 sera attribuée à la plus petite valeur dʼentrée, et la valeur dʼaffichage 10 sera attribuée à la plus grande valeur dʼentrée. En plus, le paramètre “Signal dʼentrée minimum” se verra attribuer la valeur mesurée correspondant à un contenu mesuré de 1 m3, p. ex. 5,6 mA, et le paramètre “Signal dʼentrée maximum” se verra attribuer la valeur mesurée correspondant à un contenu mesuré de 8 m3, p. ex. 16,8 mA. De cette manière, le message “hi” sera affiché pour des valeurs dʼentrée > 16,8 mA, et le message “lo” sera affiché pour des valeurs dʼentrée < 5,6 mA. La tension maximum en entrée ou le courant maximum en entrée peuvent être déplacés librement dans les plages dʼaffichage de la tension dʼentrée ou du courant dʼentrée. La tension maximum en entrée ou le courant maximum en entrée peuvent être déplacés librement dans les plages dʼaffichage de la tension dʼentrée ou du courant dʼentrée. Las valeurs affichées peuvent être déplacées librement dans la plage dʼaffichage. 18 MN05401008E Bedienungsanleitung Digitalanzeige mit Analogeingängen E5324E Serie • 5stellige Digitalanzeige mit Analogeingängen • gut ablesbare, hell leuchtende 8 mm hohe LED-Anzeige • Anzeigebereich von -19999 bis 99 999 mit Vornullenunterdrückung. • Die Programmierung der Funktionen, bzw. Betriebsparameter erfolgt über die beiden Einstelltasten. Bedienerführung auf dem Display während der Programmierroutine. • Programmierbar sind: Messbereich Maximalwertanzeige ja/nein Maximalwertrücksetzung ja/nein Minimalwertanzeige ja/nein Minimalwertrücksetzung ja/nein Dezimalpunkt Minimales Eingangssignal Anzuzeigender Wert bei kleinstem Eingangssignal Maximales Eingangssignal Anzuzeigender Wert bei höchstem Eingangssignal 2. Eingänge LATCH (Anschluss 4) Statischer Speichereingang für Anzeigestop. Bei Aktivierung (pnp) mit Eingangssignal 4 ... 30 V DC wird der momentane Messwert in der Anzeige festgehalten, bis dieser Eingang wieder freigegeben, oder sein Signalpegel unter 2 V DC absinkt. Ermittlung von Minimal- und Maximalwert läuft im Hintergrund weiter. Achtung: Zur Vermeidung von Störsignalen, die von der Spannungsversorgung herrühren ist dieser Eingang galvanisch getrennt. Für eine Messung ist daher die negativere Signalleitung mit dem analogen Bezugsmasseneingang zu verbinden. ANALOG GND (Anschluss 6) Analoger Bezugseingang Soll keine galvanische Trennung zwischen Messkreis und Versorgungsspannung notwendig sein, so ist eine Verbindung zwischen Pin 2 oder 3 und diesem Anschluss herzustellen. SPANNUNGSEINGANG (Anschluss 7) Analoger Spannungsmesseingang. Die Signalleitung mit dem analogen +-Signal ist hier anzuschließen. Bei Verpolung erscheint im Display „Err4“. Achtung: Zur Vermeidung von Störsignalen, die von der Spannungsversorgung herrühren, ist dieser Eingang galvanisch getrennt. Für eine Messung ist daher die negativere Signalleitung mit dem analogen Bezugsmasseneingang zu verbinden. STROMEINGANG (Anschluss 5) Analoger Strommesseingang mit Verpolungsschutz und Strombegrenzung auf max. 50 mA. Die Signalleitung mit dem analogen +-Signal ist hier anzuschließen. MN05401008E 19 deutsch 1. Beschreibung 3. Einstellung der Betriebsparameter 3.1 Auswahl des angezeigten Wertes und Rücksetzung von Maximal, bzw. Minimalwert Durch Drücken der rechten Taste kann zwischen der Anzeige des aktuellen Messwertes, des Maximal- und des Minimalwertes umgeschaltet werden. Durch einmaliges Betätigen wird für 2 Sekunden die aktuelle Funktion („Act“ , „Min“ oder „Max“) angezeigt. Wird innerhalb dieser Zeit die rechte Taste ein zweites mal gedrückt, so wird die aktuelle Funktion gewechselt und zur Bestätigung für ca. 2 Sekunden „Act“, „Min“ oder „Max“ angezeigt. Danach erfolgt die Anzeige des Wertes. Ist „Min“ oder „Max“ angewählt, so kann dieser Wert durch Betätigen der linken Taste gelöscht werden. Ist weder die Maximal- noch die Minimalwertspeicherung im Set-Up aktiviert, sind die Tasten im Betrieb ohne Funktion. e. Umschalten auf den nächsten Menüpunkt durch gedrückt halten der linken Taste und Betätigen der rechten Taste. f. Der jeweils letzte Menütitel ”EndPro” ermöglicht durch Anwahl von ”Yes” das Verlassen des Programmiermenüs und die Übernahme (Speicherung) der neuen Werte. Wird ”No” angewählt, beginnt die Programmierroutine von vorne, wobei die zuletzt eingestellten Werte zunächst erhalten bleiben. Diese können nun nochmals verändert oder kontrolliert werden. 4. Programmierroutine Nachfolgend sind die einstellbaren Parameter des Gerätes aufgeführt, die in der unten angegebenen Reihenfolge eingestellt werden können. Nach einem Durchlauf der Routine ist somit das Gerät vollständig programmiert. Die jeweils obere Darstellung entspricht der Werkseinstellung. 4.1 Eingangssignalbereich 0..20 mA 3.2 Einstellung der Geräteparameter 4..20 mA a. Beide Tasten auf der Vorderseite gedrückt halten und Spannungsversorgung einschalten. b. Auf dem Display erscheint 0..10 V c. Sobald die Tasten losgelassen werden erscheint im sekündlichen Wechsel der Menütitel und die aktuelle Menüpunkteinstellung. Nach Betätigen einer Taste wird nur noch die Menüpunkteinstellung angezeigt. d. Durch Drücken der rechten Taste wird die Menüpunkteinstellung jeweils um einen Wert weitergeschaltet. Wenn Zahlenwerte eingegeben werden sollen (z.B. bei der Faktoreinstellung), wird mit der linken Taste zunächst die Dekade angewählt und dann mit der Rechten der Wert eingestellt. 20 2..10 V 4.2 Maximalwertanzeige Maximalwert wird angezeigt Maximalwertanzeige wird unterdrückt und nächster Menütitel übersprungen MN05401008E Maximalwert kann mit roter Taste zurückgesetzt werden (aktueller Messwert wird neuer Maximalwert) 4.7 Minimales Eingangssignal (nur bei Messbereich 4..20 mA oder 2..10 V) Dieser Menüpunkt ermöglicht eine Einschränkung des Anzeigebereichs. (siehe auch 4.9) Je nach eingestelltem Messbereich wird a) oder b) durchlaufen a) Unterschreitet das Eingangssignal bei Messbereich 4..20 mA den hier eingestellten Wert wird „lo“ angezeigt. b) Unterschreitet das Eingangssignal bei Messbereich 2..10 V den hier eingestellten Wert wird „lo“ angezeigt. Maximalwert kann nicht zurückgesetzt werden 4.4 Minimalwertanzeige Minimalwert wird angezeigt Minimalwertanzeige wird unterdrückt und nächster Menütitel übersprungen 4.5 Minimalwertrücksetzung Minimalmalwert kann mit roter Taste zurückgesetzt werden (aktueller Messwert wird neuer Minimalwert) Minimalwert kann nicht zurückgesetzt werden 4.8 Anzeigewert bei niedrigstem Eingangssignal Dem niedrigsten Eingangssignal kann ein anzuzeigender Wert zwischen -19999 und 99999 zugeordnet werden. Die Einstellung des Dezimalpunktes wird berücksichtigt. 4.6 Dezimalpunkteinstellung Der Dezimalpunkt legt die Anzahl der angezeigten Nachkommastellen fest. 0 keine Dezimalstelle 0.0 eine Dezimalstelle 0.00 zwei Dezimalstellen 0.000 drei Dezimalstellen 0.0000 vier Dezimalstellen MN05401008E 21 deutsch 4.3 Maximalwertrücksetzung 4.9 Maximales Eingangssignal (nur bei Messbereich 4..20 mA oder 2..10 V) Dieser Menüpunkt ermöglicht eine Einschränkung des Anzeigebereichs. Je nach eingestelltem Messbereich wird a) oder b) durchlaufen a) Überschreitet das Eingangssignal bei Messbereich 4..20 mA den hier eingestellten Wert wird „hi“ angezeigt. b) Überschreitet das Eingangssignal bei Messbereich 2..10 V den hier eingestellten Wert wird „hi“ angezeigt. 4.10 Anzeigewert bei höchstem Eingangssignal Dem höchsten Eingangssignal kann ein anzuzeigender Wert zwischen -19999 und 99999 zu-geordnet werden. Die Einstellung des Dezi-malpunktes wird berück-sichtigt. 4.11 Ende der Programmierung Programmierroutine wird noch einmal durchlaufen. Bisher eingestellte Werte können überprüft und geändert werden. Programmierroutine wird beendet und alle eingestellten Werte werden als neue Parameter übernommen. Das Gerät ist anschliessend betriebs-bereit. 22 5. Anschlussbelegung 1 2 3 4 5 6 7 10 – 30 VDC GND GND LATCH 0 (4) – 20 mA DC Analog GND 0 (2) – 10 V DC 6. Technische Daten Anzeige: 5-stellige rote 7-Segment LED-Anzeige, 8 mm hohe Ziffern Messbereiche: 0 .. 10 V DC 2 .. 10 V DC 0 .. 20 mA DC 4 .. 20 mA DC Auflösung: 14 Bit Genauigkeit: < 0,1% ± 1 Digit über den gesamten Messbereich bei 20°C Umgebungstemperatur Nullabgleich: automatisch Temperaturdrift: < 70ppm/K Messgeschwindigkeit: 0,5 ... 2 Messungen/sec Strommessung: Spannungsabfall max. 2,0 V bei 20 mA Max. Strom: 50 mA Spannungsmessung: Eingangswiderstand >1 MΩ Max. Spannung 30 V Netzbrummunterdrückung: digitale Filterung 50 Hz Spannungsversorgung: 10 .. 30 V DC, galvanisch getrennt Stromaufnahme: max. 50 mA Umgebungstemperatur: -10°C ... +50°C MN05401008E -25°C ... +70°C Datensicherung: EEPROM 1 Million Speicherzyklen oder 10 Jahre ca. 50 g IP 65 (von vorne) Gewicht: Schutzart: EMV: Störabstrahlung EN 61 000-4-2/ EN 55011 Klasse B Störfestigkeit EN61000-6-2 Reinigung: Die Frontseite des Gerätes darf nur mit einem weichen, mit Wasser angefeuchteten Tuch gereinigt werden. Fehlermeldungen: Err 0* Fehler/Defekt im A/D-Teil Err 3* Fehler/Defekt beim EEPROM Err 4** Analoges Eingangssignal überschreitet den gültigen Messbereich Err 5* Fehler/Defekt beim EEPROM. Gerät nicht abgegelichen 8. Beispiele: 8.1 Temperaturmessung Ein Temperatursensor mit linearer Charakteristik (unlinearen Sensoren sind Linearisierglieder vorzuschalten) liefert bei -10 °C 0 V und bei 80 °C 10 V. Als Messbereich wird 0..10 V gewählt. 0 V ist der kleinstmögliche Messwert. Diesem Messwert kann nun der Anzeigewert -10 zugeordnet werden, entsprechend ist 10 V der größte Messwert. Diesem wird der Anzeigewert 80 zugeordnet. Die Anzeige ist nun auf den Sensor abgestimmt und kann die jeweiligen Zwischenwerte anzeigen. deutsch Lagertemperatur: Anzeigewert innerhalb des Anzeigebereichs frei verschiebbar * Bitte Gerät zur Überprüfung einschicken ** Eingangssignal und Programmierung überprüfen 7. Lieferumfang: – Digitalanzeige – Spannbügel – Frontrahmen für Schraubbefestigung Einbauquerschnitt 50x25 mm – Frontrahmen für Spannbügelbefestigung Einbauquerschnitt 50x25 mm – Dichtung – 1 Blatt selbstklebende Symbole MN05401008E 23 8.2 Füllstandsmessung Ein Füllstandssensor mit linearer Charakteristik (unlinearen Sensoren sind Linearisierglieder vorzuschalten) liefert bei leerem Behälter 5 mA und bei vollem 19 mA. Es soll bei vollem Behälter 10 m3 und bei leerem Behälter 0 m3 angezeigt werden. Als Messbereich wird 4..20 mA gewählt. 5 mA ist der kleinstmögliche Messwert. Diesem Messwert kann nun der Anzeigewert 0 zugeordnet werden, entsprechend ist 19 mA der größte Meßwert. Diesem wird der Anzeigewert 10 zugeordnet. Die Anzeige ist nun auf den Sensor abgestimmt und kann die jeweiligen Zwischenwerte anzeigen. 8.3 Entnommene Menge Es soll statt der Füllmenge, die entnommene Menge angezeigt werden. Als Messbereich wird wiederum 4..20 mA gewählt. Dem kleinsten Messwert von 5 mA wird nun ein Anzeigewert von 10 und dem größten Messwert von 19 mA ein Anzeigewert von 0 zugeordnet. 8.4 Füllstandsmeßung mit Grenzwertanzeige In einem dritten Fall soll wiederum die vorhandene Menge angezeigt werden, wobei der Behälter 10 m3 Volumen besitzt, aber maximal 8 m3 eingefüllt werden sollen, weiterhin soll der Inhalt nicht unter 1 m3 absinken. Somit soll bei Werten > 8 m3 „hi“ und bei Werten < 1 m3 „lo“ angezeigt werden. Als Messbereich wird 4..20 mA ausgewählt. Dem kleinsten Eingangswert wird der Anzeigewert 0, dem größten Eingangswert wird 10 zugeordnet. Zusätzlich wird nun im Menüpunkt „Minimales Eingangssignal“ der Meßwert eingestellt, der einem Inhalt von 1 m3 entspricht, z.B. 5,6 mA und im Menüpunkt „Maximales Eingangssignal“ der Messwert eingestellt, der dem Inhalt 8 m3, z.B. 16,8 mA entspricht. Somit wird bei Eingangswerten > 16,8 mA „hi“ und < 5,6 mA „lo“ angezeigt. Maximale Eingans-spannung, bzw. maximaler Eingangsstrom innerhalb des Eingangsspannungsbereichs, bzw. Eingangsstrombereichs frei verschiebbar. Minimale Eingansspannung, bzw. minimaler Eingangsstrom innerhalb des Eingangsspann ungs-bereichs, bzw. Eingangsstrom -bereichs frei verschiebbar. Anzeigewert innerhalb des Anzeigebereichs frei verschiebbar 24 MN05401008E Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN CARE (877-386-2273) Eaton.com © 2007 Eaton Corporation All Rights Reserved Printed in USA Publication No. MN05401008E/CPG March 2007
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Eaton E5324E Series Operating Instructions Manual

Categoría
Medir, probar
Tipo
Operating Instructions Manual

En otros idiomas