Hach LDO Addendum-Operation

Categoría
Medición
Tipo
Addendum-Operation
DOC273.98.90592
LDO sensor
05/2017, Edition 1
Addendum—Operation with the SC1500 Controller
Addendum—Betrieb mit dem SC1500 Controller
Adenda—Funcionamiento con el controlador SC1500
Addendum—Fonctionnement avec le contrôleur SC1500
Addendum—Funzionamento con il controller SC1500
Addendum—Bediening met de SC1500 Controller
Addendum—Operation med SC1500 Controller
Addenda—Działanie z kontrolerem SC1500
English..............................................................................................................................3
Deutsch.......................................................................................................................... 11
Español.......................................................................................................................... 20
Français......................................................................................................................... 29
Italiano............................................................................................................................ 38
Nederlands....................................................................................................................46
Dansk..............................................................................................................................55
Polski.............................................................................................................................. 63
2
Operation
Configure the sensor
Use the Settings menu to enter identification information for the sensor and to change options for
data handling and storage.
For information about sensor installation, refer to the user manual.
Make sure that all of the Settings menu values are correct for the application.
1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS.
2. Select an option, ENTER. The list of available options is shown in the table below.
Option Description
Name Changes the name that corresponds to the sensor on the top of the measure screen.
The name is limited to 10 characters in any combination of letters, numbers, spaces or
punctuation.
Unit Temperature–Sets the temperature units to °C (default) or °F.
Measurement–Set the measurement units in mg/L, ppm or % .
Altitude/Pressure–Set the altitude in m or ft, or set the atmospheric pressure units in
mmHg or torr. (Default value = 0 ft)
Altitude/Pressure Enter the value of the altitude or atmospheric pressure. This value must be accurate to
complete % saturation measurements and calibration in air. (Default = 0 ft).
Salinity Enter the salinity value. Salinity range: 0.00 to 250.00 parts per thousand (‰). (Default
value = 0)
Signale average Set the time interval to average signal in seconds
Cleaning interval Set the time interval for manual sensor cleaning in days (Default value = 0 days. A value
of 0 days disables the clean interval.)
Reset cleaning interval Set the time interval to the last saved clean interval
Data logger interval Sets the time interval for data storage in the data log—0.5, 1, 2, 5, 10, 15 (default), 30,
60 minutes.
Reset Restores the configurable default values for the sensor. Does not change the setting for
slope or offset.
Enter the atmospheric pressure value
The factory setting for atmospheric (air) pressure is 0 ft, or sea level. To change the default value,
use the steps in this procedure. The adjustment for air pressure is entered as either elevation or as
pressure units (preferred).
Note: Accurate air pressure is critical for saturated air calibration. Use only absolute pressure, not adjusted. If the
absolute air pressure is not known, use the correct elevation for the location.
1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>UNIT>AIR
PRESSURE/ALTITUDE.
2. Select one of the unit options listed:
Option Description
Altitude ft Feet—unit of measure for elevation
Altitude m Meters—metric unit of measure for elevation
Air pressure mmHg Millimeters of mercury—metric unit of measure for absolute air pressure
Air pressure torr Unit of measure for absolute air pressure
English 3
3. Confirm the selection. The value entry screen will show the selected units.
4. Enter the value, then confirm.
Enter a salinity correction value
Dissolved oxygen measurements in saline samples can show an apparent DO value that is very
different from the actual DO value. To correct for the influence of dissolved salts in a sample, enter a
salinity correction factor.
Note: If the presence or amount of salinity in the process is unknown, consult with the treatment facility engineering
staff.
1. Use a conductivity meter to measure the conductivity of the sample in mS/cm at a reference
temperature of 20 °C (68 °F).
2. Use Table 1 to estimate the salinity correction factor in parts per thousand (‰) saturation.
Note: The chloride ion concentration, in g/kg is equal to the chlorinity of the sample. Salinity is calculated with
the formula: Salinity = 1.80655 × chlorinity.
Salinity can be calculated with the relationship in section 2520 B of Standard Methods for the
Examination of Water and Wastewater.
1
,
3. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>SALINITY.
4. Enter the salinity correction factor and confirm.
Table 1 Salinity saturation (‰) per conductivity value (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
Calibration for measurements
The sensor is calibrated to specification at the factory. The manufacturer does not recommend
calibration unless periodically required by regulatory agencies. If calibration is required, let the sensor
come to equilibrium with the process before calibration. Do not calibrate the sensor at setup.
Table 2 shows options for calibration.
1
Standard Methods for the Examiniation of Water and Wastewater, 20th Edition. Editors Lenore
S. Clesceri, Arnold E. Greenberg and Andrew D. Eaton, p. 2-48-2-29 (1998). The relationship
between Chlorinity and Oxygen Solubitity is provided in the same reference in 4500-O:I p. 4-131.
4 English
Table 2 Calibration options
Option Description
Air calibration Recommended calibration method. This calibration modifies the slope.
Calibration Calibration by comparison with a hand-held DO meter . This calibration modifies the offset.
Reset calibration Resets the calibration gain (slope) and offset to the factory default: default gain=1.0; default
offset=0.0
Air calibration
User notes:
Make sure that calibration bag has water inside.
Make sure that the seal between the calibration bag and the sensor body is tight.
Make sure that the sensor is dry when it is calibrated.
Make sure the air pressure/elevation setting is accurate for the calibration location.
Allow enough time for the sensor temperature to stabilize to the temperature of the calibration bag
location. A large difference in temperature between the process and the calibration location can
take up to 15 minutes to stabilize.
1. Remove the sensor from the process. Use a wet cloth to clean the sensor.
2. Put the entire sensor in a calibration bag with 25-50 mL of water. Make sure that the sensor cap
is not in contact with the water inside the calibration bag and that no water drops are on the
sensor cap.
3. Use a rubber band, tie or hand to create a tight seal around the sensor body.
4. Let the instrument stabilize for 15 minutes before calibration. Keep the calibration bag out of
direct sunlight during stablization.
5. Make sure that the current absolute air pressure or elevation is configured correctly.
Note: The manufacturer recommends the use of absolute or actual air pressure as a best practice.
6. Go to MENU>SENSOR SETUP>[Select Sensor]>CALIBRATION>AIR CALIBRATION.
7. Select the option for the output signal during calibration:
Option Description
Active The instrument sends the current measured output value during the calibration procedure.
Hold The sensor output value is held at the current measured value during the calibration procedure.
Transfer A preset value is sent during calibration. Refer to the controller user manual to change the preset
value.
8. The controller will show "Put the entire sensor in the bag with water.". Allow the value to stabilize.
Push ENTER to accept the stable value. Alternately, let the calibration continue until the display
shows "Task was succesfully completed. ".
9. When the sensor is calibrated, put the sensor into the process. Push ENTER.
English
5
Figure 1 Air calibration procedure
If the value does not stabilize, the display will show "Unable to Calibrate" followed by an error
message. Table 3 shows the error message and resolution for calibration problems.
Table 3 Air calibration error messages
Message Description Resolution
Calibration failed! Gain correction is
too high.
The calculated gain value is too high. Repeat the calibration.
Calibration failed! Gain correction is
too low.
The calculated gain value is too low. Repeat the calibration.
Calibration failed! Unstable The value did not stabilize in the maximum
allowed calibration time.
Repeat the calibration.
Calibration by comparison
This calibration method uses an alternate sensor attached to a hand-held meter.
1. Put the alternate sensor into the process. Put the second sensor as close as possible to the first
sensor.
2. Wait for the DO value to stabilize.
3. On the controller for the first sensor, go to MENU>SENSOR SETUP>[Select
Sensor]>CALIBRATION>CALIBRATION.
4. Select the option for the output signal during calibration:
Option Description
Active The instrument sends the current measured output value during the calibration procedure.
Hold The sensor output value is held at the current measured value during the calibration procedure.
Transfer A preset value is sent during calibration. Refer to the controller user manual to change the preset
value.
5. The controller will show:
"Is the reading stable?"
The current dissolved oxygen measurement
The current temperature measurement
6. When the measurement is stable, push ENTER. The display will show an entry screen.
Note: The measurement will usually stabilize in 2 to 3 minutes.
6
English
If the value does not stabilize, the display will show "Unable to Calibrate" followed by an error
message. Table 4 shows the error message and resolution for calibration problems.
Table 4 Sample cal error messages
Message Description Resolution
Calibration failed! Offset is too high. The calculated offset value is too high. Repeat the calibration.
Calibration failed! Offset is too low. The calculated offset value is too low. Repeat the calibration.
Calibration failed! Unstable The value did not stabilize in the maximum allowed
calibration time.
Repeat the calibration.
Exit the calibration procedure
1. During calibration, push the BACK key. Three options are shown:
Option Description
Cancel Stop the calibration. A new calibration must start from the beginning.
Return to
calibration
Return to the current calibration.
Exit Exit the calibration temporarily. Access to other menus is allowed while the calibration
continues in the background. A calibration for a second sensor (if present) can be
started. To return to the calibration, push the MENU key and select Sensor Setup,
[Select Sensor].
2. Select one of the options. Confirm.
Reset calibration defaults
Calibration settings can be reset to the factory defaults. Gain and offset values are set to 1.0 and 0.0,
respectively.
1. Go to MENU>SENSOR SETUP>[Select Sensor]>CALIBRATION>RESET CALIBRATION.
2. The display will show a confirmation message. Confirm to reset the sensor to the factory default
calibration curve.
Maintenance
D A N G E R
Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the
document.
D A N G E R
Explosion hazard. Do not connect or disconnect electrical components or circuits to the equipment
unless power has been switched off or the area is known to be non-hazardous.
D A N G E R
Explosion hazard. Substitution of components may impair suitability for Class 1, Division 2. Do not
replace any component unless power has been switched off and the area is known to be non-
hazardous.
N O T I C E
The hazardous location certified version of this product does not fulfill the requirements of the 94/9/EC Directive
(ATEX Directive).
English 7
Maintenance schedule
The maintenance schedule shows minimum intervals for regular maintenance tasks. Perform
maintenance tasks more frequently for applications that cause electrode fouling.
Note: Do not disassemble the probe for maintenance or cleaning.
Maintenance task Recommended minimum frequency
Clean the sensor 90 days
Inspect the sensor for damage 90 days
Calibrate the sensor As recommended by regulatory agencies
Clean the sensor
Clean the exterior of the sensor with a soft, wet cloth.
Note: If the sensor cap must be removed for cleaning, do not expose the interior of the cap to direct sunlight for
extended periods of time.
Set or change the clean interval
Application conditions may need shorter or longer durations between manual sensor cleanings. The
default clean interval is 0 days. To change the interval, refer to the steps in this procedure.
1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>CLEANING INTERVAL.
2. Change the shown value as needed. Confirm the change.
To turn off the clean interval, set the value to '0'.
Change the sensor cap
W A R N I N G
Potential explosion hazard. The sensor setup cap is not rated for hazardous location use.
Replacement sensor caps and setup caps are shipped with installation instructions. Refer to the
included instructions to change the cap. After the new sensor cap is installed, make sure that the lot
number on the sensor cap is the same lot number that is read by Modbus. The sensor uses the
calibration information from the sensor cap.
For best performance and accuracy, replace the sensor cap:
Every two years, or more frequently if necessary
When routine inspection shows significant erosion of the sensor cap
Troubleshooting
Diagnostic and test menu
The diagnostic and test menu shows current and historical information about the LDO sensor.
To access the diagnostic and test menu, go to MENU>SENSOR SETUP>[Select
Sensor]>MAINTENANCE.
8
English
Refer to Table 5.
Table 5 Maintenance menu
Option Description
Sensor information Software version—Shows the installed software version
Boot pogram— Shows the installed boot version
Driver version—Shows the installed software driver version
Sensor cap lot code Shows the sensor cap manufacturing lot
Serial number Sensor serial number
Gain correction Adjust the calibration gain value.
Range: 0.50 to 2.00
Offset correction Adjust the calibration offset value (mg/L or ppm).
Range: –3.00 to +3.00
Phase diagnostics Shows the phase for total, red and blue wavelengths. Updates once per second.
Amplitude diagnostics Shows the amplitude for red and blue wavelengths. Updates once per second.
Days remaining to clean Shows the number of days until the next scheduled manual cleaning.
Sensor life Shows the number of days until the next scheduled sensor cap replacement.
Error list
If an error occurs, the reading on the measurement screen flashes. Output behavior is determined by
controller settings. Refer to the controller manual for details.
To show the current sensor errors, go to MENU>SENSOR DIAGNOSTICS>[Select Sensor]>ERROR
LIST. Refer to Table 6.
Table 6 Error list for the LDO sensor
Error Possible cause Resolution
Red amplitude is too low. (Value is below
0.01)
or
Blue amplitude is too low. (Value is below
0.01)
The sensor cap is not
installed, or is not installed
correctly.
Remove the sensor cap and
install it again.
The light path is blocked in
the sensor cap.
Inspect the inside of the sensor
cap and lens.
The sensor is not operating
correctly.
Make sure that the LED is
flashing. Contact the
manufacturer.
Warning list
When the warning icon flashes (sc100 and sc200) or when the screen turns yellow (sc1000), a
message is shown on the bottom of the measurement screen. On the sc1000, the screen turns
yellow to show a warning. To show the current sensor warnings, go to MENU>SENSOR
DIAGNOSTICS>[Select Sensor]>WARNING LIST. Refer to Table 7.
Table 7 Sensor warning list
Warning Definition Resolution
EEPROM setup error Storage is corrupt. The values have
been set to the factory default.
Contact technical support.
EEPROM error
English 9
Table 7 Sensor warning list (continued)
Warning Definition Resolution
Temperature < 0 °C The process temperature is below 0 °C
(32 °F)
Increase the process temperature or
stop use until the process temperature
is in the sensor specification range.
Temperature > 50 °C The process temperature is above 50 °C
(120 °F)
Decrease the process temperature or
stop use until the process temperature
is in the sensor specification range.
Red amplitude is too low. Value falls below 0.03 Refer to Error list on page 9 .
Red amplitude is too high. Value is greater than 0.35 Call technical support.
Blue amplitude is too low. Value is below 0.03 Refer to Error list on page 9.
Blue amplitude is too high. Value is greater than 0.35 Call technical support.
Sensor cap lot code
missing.
The sensor cap code has become
corrupt. The code has been reset
automatically to the default cap and lot
codes.
Complete the sensor setup cap
procedure. If no setup cap is available
for the sensor cap, call technical
support.
Event list
The Event list keeps a log of changes to how data is recorded by the sensor. To show sensor events,
go to MENU>SENSOR DIAGNOSTICS>[Select Sensor]>EVENT LIST.
Refer to Table 8.
Table 8 Event list for the sensor
Event Description
Altitude/Pressure unit change Atmospheric pressure or altitude units have changed.
Altitude/Pressure change The value for altitude or atmospheric pressure has changed.
Temperature change The units for temperature have changed.
Unit change A new unit of measurement has changed.
Salinity change The value for salinity has changed.
Reset Sensor settings have been reset to the default values.
Sensor setup change The sensor setup has changed.
Cleaning interval change The time between sensor cleaning has changed.
Sensor life change The time between sensor cap replacements has changed.
10 English
Betrieb
Konfigurieren des Sensors
Verwenden Sie das Menü „Einstellungen“, um eine Identifizierungsinformation für den Sensor
einzugeben und die Optionen für die Datenverwaltung und -speicherung zu ändern.
Informationen zur Sensor-Installation entnehmen Sie bitte dem Benutzerhandbuch.
Stellen Sie sicher, dass alle Werte des Menüs „Einstellungen“ für die Anwendung korrekt sind.
1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>EINSTELLUNGEN auf.
2. Wählen Sie eine Option aus, und drücken Sie EINGABE. In der folgenden Tabelle wird eine Liste
der verfügbaren Optionen angezeigt.
Optionen Beschreibung
Name Ändert den Namen des Messorts für den Sensor oben in der Messungsanzeige. Der
Name darf maximal 10 Zeichen lang sein und Buchstaben, Zahlen, Leerzeichen und
Satzzeichen enthalten.
Einheit Temperatur: Legt die Temperatureinheit fest: °C (Standard) oder °F.
Maßeinheit: Legt die Maßeinheiten (mg/l, ppm oder %) fest.
Höhe/Druck: Legt die Höhe (m oder Fuß) fest oder aber die Einheiten des
Atmosphärendrucks (mmHg oder Torr). (Standardwert = 0 m)
Höhe/Druck Geben Sie den Wert für die Höhe oder den Atmosphärendruck ein. Dieser Wert
muss genau sein, um die Messung der Sättigung in % und die Kalibrierung in Luft
abschließen zu können. (Standardwert = 0 m)
Salinität Geben Sie den Wert des Salzgehalts ein. Bereich des Salzgehalts: 0,00 bis
250,00 Promille (‰). (Standardwert = 0)
Mittelwert Legen Sie das Zeitintervall für den Mittelwert des Signals in Sekunden fest.
Reinigungsintervall Legen Sie das Zeitintervall für die manuelle Sensorreinigung in Tagen fest
(Standardwert = 0 Tage. Mit einem Wert von 0 Tagen wird das Reinigungsintervall
deaktiviert.)
Reinigungsintervall
zurücksetzen
Setzt das Reinigungsintervall zurück.
Datenlogger-Intervall Legt das Zeitintervall für die Datenspeicherung im Datenprotokoll fest: 0,5, 1, 2, 5,
10, 15 (Standardwert), 30 oder 60 Minuten.
Zurücksetzen Stellt die konfigurierbaren Standardwerte des Sensors wieder her. Ändert nicht die
Einstellung für Steilheit oder Offset.
Eingeben des Atmosphärendrucks
Die Werkseinstellung für den atmosphärischen (Luft-)Druck entspricht 0 m bzw. Normalnull. Befolgen
Sie die Schritte in dieser Vorgehensweise, um den Standardwert zu ändern. Die Anpassung des
Luftdrucks wird entweder als Höhe oder in Druckeinheiten (empfohlen) eingegeben.
Hinweis: Für die Kalibrierung in gesättigter Luft ist der genaue Luftdruck entscheidend. Verwenden Sie nur den
absoluten Luftdruck, nicht den angepassten. Falls der absolute Luftdruck nicht bekannt ist, verwenden Sie die dem
Standort entsprechende Höhe.
1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>EINSTELLUNGEN>LUFTDRUCK/HÖHE auf.
2. Wählen Sie eine der aufgeführten Einheitenoptionen aus:
Optionen Beschreibung
Höhe ft Fuß: Maßeinheit für Höhe
Deutsch 11
Optionen Beschreibung
Höhe m Meter: metrische Maßeinheit für Höhe
Luftdruck mmHg Millimeter Quecksilber: metrische Maßeinheit für absoluten Luftdruck
Luftdruck Torr Maßeinheit für absoluten Luftdruck
3. Bestätigen Sie die Auswahl. Im Bildschirm für die Werteeingabe werden die ausgewählten
Einheiten angezeigt.
4. Geben Sie den Wert ein und bestätigen Sie diesen anschließend.
Eingeben eines Salzgehalt-Korrekturwerts
Bei Messungen von gelöstem Sauerstoff in salzigen Proben kann ein Sauerstoff-Wert angezeigt
werden, der sich stark von dem tatsächlichen Sauerstoff-Wert unterscheidet. Zur Korrektur des
Einflusses von gelösten Salzen in einer Probe geben Sie einen Salzgehalt-Korrekturwert ein.
Hinweis: Falls das Vorhandensein von Salz oder der Grad des Salzgehalts in dem Prozess unbekannt ist,
konsultieren Sie das technische Personal der Behandlungsanlage.
1. Mit einer Leitfähigkeitsmessung bestimmen Sie die Leitfähigkeit der Probe in mS/cm bei einer
Referenztemperatur von 20 °C.
2. Anhand von Tabelle 1 schätzen Sie den Korrekturfaktor für den Salzgehalt in Promille (‰) der
Sättigung.
Hinweis: Die Chloridionenkonzentration in g/kg entspricht dem Chloridgehalt in der Probe. Der Salzgehalt wird
mit folgender Formel berechnet: Salzgehalt = 1,80655 x Chloridgehalt.
Der Salzgehalt kann anhand des Verhältnisses in Abschnitt 2520 B der Standardmethoden für
die Untersuchung von Wasser und Abwasser berechnet werden.
1
,
3. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>EINSTELLUNGEN>SALZGEHALT auf.
4. Geben Sie den Salzgehalt-Korrekturwert ein und bestätigen Sie diesen.
Tabelle 1 Salzgehaltsättigung (‰) pro Leitfähigkeitswert (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
1
Standardmethoden für die Untersuchung von Wasser und Abwasser, 20. Ausgabe. Herausgeber
Lenore S. Clesceri, Arnold E. Greenberg und Andrew D. Eaton, S. 2-48-2-29 (1998). Das
Verhältnis zwischen Chloridgehalt und Sauerstofflöslichkeit ist in derselben Referenz in 4500-O:I
S. 4-131 angegeben.
12 Deutsch
Kalibrierung für Messungen
Der Sensor wird im Werk gemäß den Spezifikationen kalibriert. Der Hersteller empfiehlt keine
Kalibrierung, es sei denn, dies wird regelmäßig von Kontrollorganen gefordert. Falls eine Kalibrierung
erforderlich ist, lassen Sie den Sensor mit dem Prozess ins Gleichgewicht kommen, bevor Sie eine
Kalibrierung durchführen. Kalibrieren Sie den Sensor nicht beim Setup.
In Tabelle 2 werden Optionen für die Kalibrierung angezeigt.
Tabelle 2 Kalibrieroptionen
Optionen Beschreibung
Luftkalibrierung Empfohlene Kalibrierungsmethode. Durch diese Kalibrierung wird die Steilheit
verändert.
Kalibrierung Kalibrierung durch Vergleich mit einem tragbaren Sauerstoff-Messgerät. Durch diese
Kalibrierung wird der Offset verändert.
Kalibrierung zurücksetzen Setzt den Stellfaktor der Kalibrierung (Steilheit) und den Offset auf den
Werksstandard: standardmäßiger Stellfaktor = 1,0; standardmäßiger Offset = 0,0.
Luftkalibrierung
Benutzerhinweise:
Vergewissern Sie sich, dass sich Wasser im Kalibrierungsbeutel befindet.
Vergewissern Sie sich, dass die Dichtung zwischen dem Kalibrierungsbeutel und dem
Sensorgehäuse dicht ist.
Vergewissern Sie sich, dass der Sensor beim Kalibrieren trocken ist.
Vergewissern Sie sich, dass die Luftdruck-/Höheneinstellung für den Kalibrierungsstandort akkurat
ist.
Lassen Sie dem Sensor genügend Zeit, die Temperatur des Standortes des Kalibrierungsbeutels
anzunehmen. Bei einem großen Temperaturunterschied zwischen dem Prozess und dem
Kalibrierungsstandort kann die Temperaturstabilisierung bis zu 15 Minuten in Anspruch nehmen.
1. Entnehmen Sie den Sensor aus dem Prozess. Reinigen Sie den Sensor mit einem feuchten
Tuch.
2. Geben Sie den gesamten Sensor in einen Kalibrierungsbeutel mit 25 bis 50 ml Wasser.
Vergewissern Sie sich, dass die Sensorkappe keinen Kontakt zu dem Wasser im
Kalibrierungsbeutel hat und dass sich keine Wassertropfen auf der Sensorkappe befinden.
3. Dichten Sie mit Hilfe eines Gummibands, eines Bindfadens oder der Hand den Kalibrierbeutel
zum Sensor hin ab.
4. Lassen Sie dem Messgerät vor der Kalibrierung 15 Minuten Zeit, sich zu stabilisieren. Setzen Sie
den Kalibrierungsbeutel während der Kalibrierung nicht direktem Sonnenlicht aus.
5. Vergewissern Sie sich, dass der aktuelle absolute Luftdruck bzw. die Höhenangabe
ordnungsgemäß konfiguriert ist.
Hinweis: Der Hersteller empfiehlt die Verwendung des absoluten bzw. tatsächlichen Luftdrucks als empfohlene
Vorgehensweise.
6. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>KALIBRIERUNG>LUFTKALIBRIERUNG auf.
7. Wählen Sie eine Option für das Ausgangssignal während der Kalibrierung:
Optionen Beschreibung
Aktiv Das Gerät übermittelt während der Kalibrierung den aktuellen Messwert.
Halten Das Gerät hält den aktuellen Messwert während der Kalibrierung.
Ersatzwert Das Gerät übermittelt während der Kalibrierung einen vorher eingestellten Wert. Informationen
zur Einstellung des Ersatzwertes entnehmen Sie bitte der Bedienungsanleitung des Controllers.
Deutsch 13
8. Auf dem Controller wird Folgendes angezeigt: „Geben Sie den gesamten Sensor in den Beutel
mit Wasser.“ Lassen Sie dem Wert Zeit, sich zu stabilisieren. Drücken Sie ENTER, um den
stabilen Wert zu akzeptieren. Alternativ kann die Kalibrierung fortgesetzt werden, bis Folgendes
angezeigt wird: „Aufgabe wurde erfolgreich beendet. “
9. Wenn der Sensor kalibriert ist, fügen Sie den Sensor in den Prozess ein. Drücken Sie ENTER.
Abbildung 1 Luftkalibrierung
Wenn sich der Wert nicht stabilisiert, wird in der Anzeige "Kann nicht kalibrieren" gefolgt von einer
Fehlermeldung angezeigt. In Tabelle 3 werden die Fehlermeldung und die Auflösung für
Kalibrierungsprobleme angezeigt.
Tabelle 3 Fehlermeldungen beim Kalibrieren mit Luft
Meldung Beschreibung Auflösung
Kalibrierung fehlgeschlagen!
Korrekturfaktor ist zu hoch.
Der berechnete Verstärkungswert ist zu hoch. Kalibrierung wiederholen.
Kalibrierung fehlgeschlagen!
Korrekturfaktor ist zu niedrig.
Der berechnete Verstärkungswert ist zu
niedrig.
Kalibrierung wiederholen.
Kalibrierung fehlgeschlagen! Instabil Der Wert hat sich in der maximal zulässigen
Kalibrierungszeit nicht stabilisiert.
Kalibrierung wiederholen.
Kalibrierung durch Vergleich
Bei dieser Kalibrierung wird ein alternativer Sensor verwendet, der an ein tragbares Messgerät
angeschlossen ist.
1. Fügen Sie den alternativen Sensor in den Prozess ein. Fügen Sie den zweiten Sensor so nahe
wie möglich neben dem ersten Sensor ein.
2. Warten Sie, bis der Sauerstoff-Wert stabil ist.
3. Rufen Sie auf dem Controller für den ersten Sensor MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>KALIBRIERUNG>KALIBRIERUNG auf.
4. Wählen Sie eine Option für das Ausgangssignal während der Kalibrierung:
Optionen Beschreibung
Aktiv Das Gerät übermittelt während der Kalibrierung den aktuellen Messwert.
Halten Das Gerät hält den aktuellen Messwert während der Kalibrierung.
Ersatzwert Das Gerät übermittelt während der Kalibrierung einen vorher eingestellten Wert. Informationen
zur Einstellung des Ersatzwertes entnehmen Sie bitte der Bedienungsanleitung des Controllers.
14 Deutsch
5. Auf dem Controller wird Folgendes angezeigt:
„Ist der Messwert stabil?“
Die aktuelle Messung des gelösten Sauerstoffs
Die aktuelle Temperaturmessung
6. Wenn der Messwert stabil ist, drücken Sie ENTER. Auf dem Display wird ein Eingabebildschirm
angezeigt.
Hinweis: Die Messung stabilisiert sich in der Regel in 2 bis 3 Minuten.
Wenn sich der Wert nicht stabilisiert, wird in der Anzeige "Kann nicht kalibrieren" gefolgt von einer
Fehlermeldung angezeigt. In Tabelle 4 werden die Fehlermeldung und die Auflösung für
Kalibrierungsprobleme angezeigt.
Tabelle 4 Fehlermeldungen bei der IN-LINE Kalibrierung
Meldung Beschreibung Auflösung
Kalibrierung fehlgeschlagen! Offset ist
zu hoch.
Der berechnete Offsetwert ist zu hoch. Kalibrierung wiederholen.
Kalibrierung fehlgeschlagen! Offset ist
zu tief.
Der berechnete Offsetwert ist zu niedrig. Kalibrierung wiederholen.
Kalibrierung fehlgeschlagen! Instabil Der Wert hat sich in der maximal zulässigen
Kalibrierungszeit nicht stabilisiert.
Kalibrierung wiederholen.
Verlassen der Kalibrierungsprozedur
1. Drücken Sie während der Kalibrierung die Taste ZURÜCK. Es werden drei Optionen angezeigt:
Optionen Beschreibung
Abbrechen Stoppt die Kalibrierung. Eine neue Kalibrierung muss von Anfang an ausgeführt
werden.
Zurück zur
Kalibrierung
Kehrt zur aktuellen Kalibrierung zurück.
Beenden Verlässt die Kalibrierung vorübergehend. Zugriff auf andere Menüs ist zulässig,
während die Kalibrierung im Hintergrund fortgesetzt wird. Sofern vorhanden, kann
die Kalibrierung eines zweiten Sensors gestartet werden. Um zur Kalibrierung
zurückzukehren, drücken Sie MENÜ und wählen Sie „Sensor-Setup“, [Sensor
wählen].
2. Wählen Sie eine der Optionen aus. Bestätigen Sie die Auswahl.
Zurücksetzen der Kalibrierung auf die Standardwerte
Kalibrierungseinstellungen können auf die werkseitigen Standardwerte zurückgesetzt werden. Die
Werte für Stellfaktor und Offset werden auf 1,0 bzw. 0,0 gesetzt.
1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>KALIBRIERUNG>KALIBRIERUNG ZURÜCKSETZEN auf.
2. Im Display wird eine Bestätigungsmeldung angezeigt. Bestätigen Sie, dass Sie den Sensor auf
die werkseitige Standardkalibrierungskurve zurücksetzen möchten.
Wartung
G E F A H R
Mehrere Gefahren. Nur qualifiziertes Personal sollte die in diesem Kapitel des Dokuments
beschriebenen Aufgaben durchführen.
Deutsch 15
G E F A H R
Explosionsgefahr. Elektrische Komponenten oder Schaltungen nur bei ausgeschalteter
Stromversorgung oder in ungefährlichen Bereichen anschließen oder abtrennen.
G E F A H R
Explosionsgefahr. Das Austauschen von Komponenten kann die Eignung für Klasse I, Unterteilung 2,
beeinträchtigen. Komponenten nur bei ausgeschalteter Stromversorgung und in ungefährlichen
Bereichen austauschen.
H I N W E I S
Die für gefährliche Standorte zertifizierte Version dieses Produkts erfüllt nicht die Anforderungen der
Richtlinie 94/9/EG (ATEX-Richtlinie).
Wartungsplan
Im Wartungsplan sind die Mindestintervalle für die regelmäßige Wartung angegeben. Führen Sie die
Wartungsaufgaben häufiger aus, wenn die Anwendungsbedingungen zum Zusetzen oder zu
Verunreinigungen der Elektrode führen.
Hinweis: Nehmen Sie das Gerät zur Wartung oder Reinigung nicht auseinander.
Wartungsaufgabe Empfohlene Häufigkeit
Reinigen des Sensors 90 Tage
Sensor auf Schäden prüfen 90 Tage
Kalibrieren des Sensors Wie von Kontrollorganen empfohlen
Reinigen des Sensors
Reinigen Sie das Äußere des Sensors mit einem weichen, feuchten Tuch.
Hinweis: Wenn die Sensorkappe zum Reinigen entfernt werden muss, setzen Sie das Innere der Kappe nicht über
einen längeren Zeitraum direktem Sonnenlicht aus.
Festlegen oder Ändern des Reinigungsintervalls
Anwendungsbedingungen erfordern u. U. kürzere oder längere Zeitabstände zwischen manuellen
Sensorreinigungen. Das Standardreinigungsintervall beträgt 0 Tage. Befolgen Sie die Schritte in
dieser Vorgehensweise, um das Intervall zu ändern.
1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor
auswählen]>EINSTELLUNGEN>REINIGUNGSINTERVALL auf.
2. Ändern Sie den angezeigten Wert nach Bedarf. Bestätigen Sie die Änderung.
Um das Reinigungsintervall abzuschalten, setzen Sie den Wert auf "0".
Wechseln der Sensorkappe
W A R N U N G
Mögliche Explosionsgefahr. Die Sensor-Kalibrierkappe ist nicht für die Verwendung an gefährlichen
Standorten ausgelegt.
Ersatz-Sensorkappen und Kalibrierkappen werden mit den Installationsanweisungen mitgeliefert.
Befolgen Sie die entsprechenden Anweisungen, um die Kappe zu wechseln. Stellen Sie nach dem
Anbringen der Sensorkappe sicher, dass die Chargennummer auf der Sensorkappe dieselbe ist, wie
die, die von Modbus gelesen wird. Der Sensor nutzt die Kalibrierinformationen von der Sensorkappe.
16
Deutsch
Um beste Leistung und Genauigkeit zu erzielen, ersetzen Sie die Sensorkappe:
alle zwei Jahre, oder häufiger, falls erforderlich,
wenn bei routinemäßiger Inspektion erhebliche Erosion festgestellt wird
Fehlersuche und Behebung
Diagnose- und Testmenü
Im Diagnose- und Testmenü werden aktuelle und Langzeit-Informationen über den LDO-Sensor
angezeigt.
Um das Diagnose- und Testmenü aufzurufen, rufen Sie
MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>WARTUNG auf.
Siehe Tabelle 5.
Tabelle 5 Wartungsmenü
Optionen Beschreibung
Sensorinformationen Softwareversion: Zeigt die installierte Softwareversion an
Boot-Programm: Zeigt die installierte Boot-Version an
Treiberversion: Zeigt die installierte Treiberversion an
Sensorkappe-Chargencode Zeigt die Chargennummer der Sensorkappe an
Seriennummer Seriennummer des Sensors
Korrekturfaktor Passt den Stellfaktor der Kalibrierung an.
Bereich. 0,50 bis 2,00
Offset-Korrektur Passt den Offsetwert der Kalibrierung an (mg/l oder ppm).
Bereich: – 3,00 bis + 3,00
Phase Zeigt die Phase für alle, die roten und die blauen Wellenlängen an. Wird einmal
pro Sekunde aktualisiert.
Amplitude Zeigt die Amplitude für alle, die roten und die blauen Wellenlängen an. Wird
einmal pro Sekunde aktualisiert.
Verbleibende Tage bis zur
Reinigung
Zeigt den Zeitraum bis zur nächsten geplanten manuellen Reinigung in Tagen an.
Lebensdauer des Sensors Zeigt den Zeitraum bis zum nächsten geplanten Austausch der Sensorkappe in
Tagen an..
Fehlerliste
Wenn ein Fehler auftritt, blinkt die Messung auf dem Messbildschirm. Das Ausgabeverhalten wird
von den Controllereinstellungen bestimmt. Details dazu finden Sie im Benutzerhandbuch des
Controllers.
Deutsch
17
Um die aktuellen Sensorfehler anzuzeigen, rufen Sie MENÜ>SENSORSTATUS>[Sensor
auswählen]>FEHLERLISTE auf. Siehe Tabelle 6.
Tabelle 6 Fehlerliste für den Sauerstoff-Sensor
Fehler Mögliche Ursache Auflösung
Rote Amplitude ist zu niedrig. (Wert liegt
unter 0,01)
oder
Blaue Amplitude ist zu niedrig. (Wert liegt
unter 0,01)
Die Sensorkappe ist nicht oder
nicht richtig angebracht.
Nehmen Sie die Sensorkappe ab,
und bringen Sie sie erneut an.
Der Strahlengang in der
Sensorkappe ist blockiert.
Inspizieren Sie die Innenseite der
Sensorkappe und die Linse.
Der Sensor funktioniert nicht
ordnungsgemäß.
Vergewissern Sie sich, dass die
LED blinkt. Wenden Sie sich an
den Hersteller.
Warnungen
Wenn das Symbol „Warnungen“ blinkt (sc100 und sc200) oder wenn der Bildschirm sich gelb färbt
(sc1000), wird unten im Messbildschirm eine Mitteilung angezeigt. Beim sc1000 wird der Bildschirm
gelb, um eine Warnung anzuzeigen. Um die aktuellen Sensorwarnungen anzuzeigen, rufen Sie
MENÜ>SENSORSTATUS>[Sensor auswählen]>WARNUNGSLISTE auf. Siehe Tabelle 7.
Tabelle 7 Warnungsliste Sensor
Warnung Definition Auflösung
EEPROM-Fehler Speicher ist beschädigt. Die Werte
wurden auf den werkseitigen
Standardwert gesetzt.
Wenden Sie sich an den technischen
Kundenservice.
EEPROM-Fehler
Temperatur < 0 C Die Prozesstemperatur liegt unter 0 °C Erhöhen Sie die Prozesstemperatur oder
warten Sie, bis die Prozesstemperatur sich
im sensorspezifischen Bereich befindet.
Temperatur > 50 C Die Prozesstemperatur liegt über 50 °C Senken Sie die Prozesstemperatur oder
warten Sie, bis die Prozesstemperatur sich
im sensorspezifischen Bereich befindet.
Rote Amplitude ist zu
niedrig.
Wert fällt unter 0,03 Siehe Fehlerliste auf Seite 17.
Rote Amplitude ist zu
hoch.
Wert ist größer als 0,35 Wenden Sie sich an den technischen
Kundenservice.
Blaue Amplitude ist zu
niedrig.
Wert liegt unter 0,03 Siehe Fehlerliste auf Seite 17.
Blaue Amplitude ist zu
hoch.
Wert ist größer als 0,35 Wenden Sie sich an den technischen
Kundenservice.
Sensorkappe-
Chargencode fehlt.
Der Code der Sensorkappe wurde
beschädigt. Der Code wurde
automatisch auf die standardmäßigen
Codes für die Kappe und Charge
zurückgesetzt.
Vervollständigen Sie die Vorgehensweise
zum Einrichten der Sensorkappe. Wenn für
die Sensorkappe keine Setup-Kappe
vorhanden ist, wenden Sie sich an den
technischen Kundendienst.
Ereignisliste
In der Ereignisliste werden Änderungen bei der Aufzeichnung von Daten durch den Sensor
protokolliert. Um Sensorereignisse anzuzeigen, rufen Sie MENÜ>SENSORSTATUS>[Sensor
auswählen]>EREIGNISLISTE auf.
18
Deutsch
Siehe Tabelle 8.
Tabelle 8 Liste möglicher Sensorereignisse
Ereignis Beschreibung
Änderung der Maßeinheit für Höhe/Druck Maßeinheiten für Atmosphärendruck oder Höhe wurden geändert.
Änderung der Höhe/des Drucks Der Wert für die Höhe oder den Atmosphärendruck wurde geändert.
Änderung der Temperatur Maßeinheiten für Temperatur wurden geändert.
Änderung der Maßeinheit Eine Maßeinheit wurde geändert.
Änderung des Salzgehalts Der Wert für den Salzgehalt wurde geändert.
Zurücksetzen Sensoreinstellungen wurden auf Standardwerte zurückgesetzt.
Änderung der Sensoreinstellungen Das Sensor-Setup wurde geändert.
Änderung des Reinigungsintervalls Der Zeitraum zwischen den Sensorreinigungen wurde geändert.
Änderung der Lebensdauer des Sensors Der Zeitraum für den Austausch der Sensorkappen wurde geändert.
Deutsch 19
Funcionamiento
Configuración del sensor
Utilice el menú Configuración para introducir la información de identificación del sensor y para
cambiar las opciones para el manejo y almacenamiento de datos.
Si desea información sobre la instalación del sensor, consulte el manual del usuario.
Asegúrese de que los valores del menú Configuración son correctos para la aplicación.
1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CONFIGURACIÓN.
2. Seleccione una opción y, a continuación, pulse ENTER (Intro). A continuación, se enumeran las
opciones disponibles en una tabla.
Opción Descripción
Nombre Cambia el nombre que corresponde al sensor en la parte superior de la pantalla de
medición. El nombre puede contener hasta 10 caracteres en cualquier
combinación de letras, números, espacios o signos de puntuación.
Unidad Temperatura: configura las unidades de temperatura en ºC (configuración
predeterminada) o ºF.
Medición: configura las unidades de medición en mg/l, ppm o %.
Altitud/Presión: configura la altitud en m o pies, o configura las unidades de
presión atmosférica en mmHg o torr. (Valor predeterminado = 0 pies)
Altitud/Presión Introduzca el valor de la altitud o presión atmosférica. Este valor debe ser preciso
para completar la calibración y las mediciones de la saturación en % del aire.
(Predeterminado = 0 pies).
Salinidad Introduzca el valor de salinidad. Intervalo de salinidad: de 0,00 a 250,000 partes
por mil (‰). (Valor predeterminado = 0).
Promedio de señal Configure el intervalo de tiempo al promedio de señal en segundos.
Cleaning interval (Intervalo
de limpieza)
Establezca el intervalo de tiempo para la limpieza manual del sensor en días.
(Valor predeterminado = 0 días. Un valor de 0 días desactiva el intervalo de
limpieza).
Reset cleaning interval
(Restablecer intervalo de
limpieza)
Establezca el intervalo de tiempo al último intervalo de limpieza guardado.
Data logger interval
(Intervalo de registro de
datos)
Establece el intervalo de tiempo del almacenamiento de datos en el registro de
datos: 0,5, 1, 2, 5, 10, 15 (predeterminado), 30 y 60 minutos.
Restablecimiento Restablece los valores predeterminados configurables para el sensor. No
modifique los ajustes para la pendiente o el desvío.
Introducción de la unidad de presión atmosférica
La configuración de fábrica de la presión atmosférica (aire) es de 0 pies o del nivel del mar. Para
cambiar el valor predeterminado, siga los pasos de este procedimiento. El ajuste de la presión del
aire se introduce como unidades de elevación o de presión (preferido).
Nota: Para la calibración de aire saturado es fundamental una exacta presión del aire. Utilice únicamente presión
absoluta, no ajustada. Si se desconoce la presión absoluta del aire, utilice la elevación correcta para la ubicación.
20
Español
1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CONFIGURACIÓN>UNIDAD>PRESIÓN DEL AIRE/ALTITUD.
2. Seleccione una de las opciones de unidades que se enumeran:
Opción Descripción
Altitud en pies Pie: unidad de medida para la elevación
Altitud: m Metros: unidad métrica de medición de la elevación
Air pressure mmHg (Presión del aire
en mmHg)
Milímetros de mercurio: unidad métrica de medición de la presión
absoluta del aire
Air pressure torr (Presión del aire en
torr)
Unidad de medición de la presión absoluta del aire
3. Confirme la selección. La pantalla de introducción del valor le mostrará las unidades
seleccionadas.
4. Introduzca el valor y, a continuación, confírmelo.
Introducción de un valor de corrección de salinidad
Las mediciones de oxígeno disuelto en muestras de salino pueden mostrar un valor aparente del
oxígeno disuelto muy diferente del valor actual de oxígeno disuelto. Para corregir la influencia de
sales disueltas en una muestra, introduzca un factor de corrección de salinidad.
Nota: Si se desconoce la presencia o la cantidad de salinidad del proceso, póngase en contacto con el personal de
ingeniería del centro de tratamiento.
1. Utilice un medidor de conductividad para medir la conductividad de la muestra en mS/cm a una
temperatura de referencia de 20 °C (68 °F).
2. Utilice la Tabla 1 para calcular el factor de corrección de salinidad en una saturación en partes
por mil (‰).
Nota: La concentración de iones cloruro, en g/kg, equivale a la clorinidad de la muestra. La salinidad se calcula
con la fórmula: Salinidad = 1,80655 × clorinidad.
La salinidad puede calcularse con la relación de la sección 2520 B de Standard Methods for the
Examination of Water and Wastewater (Métodos estándar para la evaluación de las aguas y las
aguas residuales).
1
,
3. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CONFIGURACIÓN>SALINIDAD.
4. Introduzca el factor de corrección de salinidad y confírmelo.
1
Standard Methods for the Examiniation of Water and Wastewater, Edición 20.º. Editores: Lenore
S. Clesceri, Arnold E. Greenberg y Andrew D. Eaton, pág. 2-48-2-29 (1998). La relación entre la
clorinidad y la solubilidad del oxígeno se proporciona en la misma obra de referencia, en 4500-
O:I, pág. 4-131.
Español 21
Tabla 1 Saturación de la salinidad (‰) por valor de conductividad (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
Calibración de las mediciones
El sensor se calibra en fábrica de acuerdo con las especificaciones. El fabricante no recomienda que
se calibre a menos que las agencias de regulación soliciten calibraciones periódicas. En caso que se
requiera una calibración, deje que el sensor se equilibre con el proceso antes de calibrarlo. No
calibre el sensor durante la configuración.
En la Tabla 2 se muestran las opciones de calibración.
Tabla 2 Opciones de calibración
Opción Descripción
Calibración en aire Método de calibración recomendado. Esta calibración modifica la pendiente.
Calibración Calibración por comparación con un medidor manual de oxígeno disuelto. Esta
calibración modifica el desvío.
Restablecer calibración Restablece la ganancia (pendiente) y el desvío de la calibración a los valores
predeterminados de fábrica: ganancia predeterminada = 1,0; desvío predeterminado =
0,0
Calibración en aire
Notas para el usuario:
Asegúrese de que la bolsa de calibración contiene agua en el interior.
Asegúrese de que el sellado entre la bolsa de calibración y el cuerpo del sensor es hermético.
Asegúrese de que el sensor está seco cuando lo vaya a calibrar.
Asegúrese de que los ajustes de la elevación y la presión del aire son adecuados para el lugar de
calibración.
Deje tiempo suficiente para que la temperatura del sensor se estabilice con la temperatura del
lugar de la bolsa de calibración. Si existe una gran diferencia entre la temperatura del proceso y la
temperatura del lugar de calibración, es posible que el sensor tarde en estabilizarse hasta
15 minutos.
1. Retire el sensor del proceso. Utilice un paño húmedo para limpiar el sensor.
2. Ponga el sensor en su conjunto en una bolsa de calibración con unos 25 o 50 ml de agua.
Asegúrese de que la cápsula del sensor no entra en contacto con el agua del interior de la bolsa
de calibración y que no caen gotas de agua en la cápsula del sensor.
22
Español
3. Utilice una correa o lazo de goma o la mano para crear un sellado hermético alrededor del
cuerpo del sensor.
4. Deje que el instrumento se estabilice durante 15 minutos antes de calibrarlo. Evite que la bolsa
de calibración entre en contacto directo con la luz solar durante la calibración.
5. Asegúrese de que la elevación o la presión absoluta del aire actual estén configuradas
correctamente.
Nota: El fabricante recomienda el uso de una presión real o absoluta del aire como buena práctica.
6. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CALIBRACIÓN>CALIBRACIÓN EN AIRE.
7. Seleccione la opción de la señal de salida durante la calibración:
Opción Descripción
Activo Durante el proceso de calibración el instrumento envía el valor de medición
actual de salida.
Hold (Retenido) Durante el proceso de calibración el valor de salida del sensor se mantiene en el
valor de medición actual.
Transfer (Transferencia) Durante el proceso de calibración se envía un valor predeterminado. Consulte el
manual del usuario del controlador para cambiar el valor predeterminado.
8. En el controlador se mostrará "Put the entire sensor in the bag with water." (Introduzca
completamente el sensor en la bolsa con agua.). Deje que el valor se estabilice. Pulse ENTER
(Intro) para aceptar el valor estable. También puede dejar que la calibración continúe hasta que
en la pantalla se muestre "La tarea se ha realizado correctamente. ".
9. Cuando se haya calibrado el sensor, póngalo en proceso. Pulse ENTER (Intro).
Figura 1 Procedimiento de calibración del aire
Si el valor no se estabiliza, en la pantalla se mostrará el mensaje "Unable to Calibrate" (No se puede
calibrar), seguido de un mensaje de error. En la Tabla 3 se muestran los mensajes de error y las
soluciones para los problemas de calibración.
Tabla 3 Mensajes de error de la calibración del aire
Mensaje Descripción Resolución
Error de calibración. Corrección de
ganancia muy alta.
El valor de ganancia calculado es demasiado
elevado.
Repita la calibración.
Error de calibración. Corrección de
ganancia muy baja.
El valor de ganancia calculado es demasiado
bajo.
Repita la calibración.
Error de calibración. Inestable El valor no se estabilizó en el tiempo máximo
de calibración permitido.
Repita la calibración.
Español 23
Calibración por comparación.
El método de calibración utiliza un sensor alternativo conectado a un medidor manual.
1. Ponga en funcionamiento el sensor alternativo. Coloque el segundo sensor lo más próximo
posible al primer sensor.
2. Espere a que el valor de oxígeno disuelto se estabilice.
3. En el controlador para el primer sensor, vaya a MENU (Menú)>CONFIGURACIÓN DEL
SENSOR>[Seleccione el sensor]>CALIBRACIÓN>CALIBRACIÓN.
4. Seleccione la opción de la señal de salida durante la calibración:
Opción Descripción
Activo Durante el proceso de calibración el instrumento envía el valor de medición
actual de salida.
Hold (Retenido) Durante el proceso de calibración el valor de salida del sensor se mantiene en el
valor de medición actual.
Transfer (Transferencia) Durante el proceso de calibración se envía un valor predeterminado. Consulte el
manual del usuario del controlador para cambiar el valor predeterminado.
5. En el controlador se mostrará:
"¿La lectura es estable?"
La medición actual de oxígeno disuelto
La medición actual de la temperatura
6. Cuando la medición sea estable, pulse INTRO. Se visualizará una pantalla de entrada.
Nota: Normalmente, la medición se tarda en estabilizarse entre 2 y 3 minutos.
Si el valor no se estabiliza, en la pantalla se mostrará el mensaje "Unable to Calibrate" (No se puede
calibrar), seguido de un mensaje de error. En la Tabla 4 se muestran los mensajes de error y las
soluciones para los problemas de calibración.
Tabla 4 Mensajes de error de la calibración de muestra
Mensaje Descripción Resolución
Error de calibración. Compensación
muy alta.
El valor calculado de desvío es demasiado
elevado.
Repita la calibración.
Error de calibración. Compensación
muy baja.
El valor calculado de desvío es demasiado
bajo.
Repita la calibración.
Error de calibración. Inestable El valor no se estabilizó en el tiempo máximo
de calibración permitido.
Repita la calibración.
Salida del proceso de calibración
1. Durante la calibración, pulse la tecla BACK (Atrás). Aparecerán tres opciones:
Opción Descripción
Cancelar Detiene el proceso de calibración. Se deberá comenzar con una nueva calibración
desde el principio.
Volver a la
calibración
Vuelve a la calibración actual.
Salir Sale del proceso de calibración provisoriamente. Se puede acceder a otros menús
mientras continúa la calibración. Se puede iniciar la calibración de un segundo sensor
(en caso que lo hubiera). Para volver al proceso de calibración, pulse la tecla MENU
(MENÚ) y seleccione Sensor Setup (Configuración del sensor), [seleccione el sensor].
2. Seleccione una de las opciones. Confirme.
24
Español
Restablecimiento de los valores predeterminados de la calibración
La configuración de la calibración puede restablecerse con los valores predeterminados de fábrica.
Los valores de ganancia y desvío se establecen al 1,0 y al 0,0, respectivamente.
1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CALIBRACIÓN>RESTABLECER CALIBRACIÓN.
2. En la pantalla se mostrará un mensaje de confirmación. Confirme que desea restablecer el
sensor con la curva de calibración predeterminada de fábrica.
Mantenimiento
P E L I G R O
Peligros diversos. Sólo el personal cualificado debe realizar las tareas descritas en esta sección del
documento.
P E L I G R O
Peligro de explosión. Evite conectar o desconectar componentes o circuitos eléctricos sin antes
desconectar la alimentación eléctrica, a menos que se sepa que esa porción del equipo no presenta
riesgos.
P E L I G R O
Peligro de explosión. Es posible que la sustitución de algún componente perjudique a la conformidad
con la Clase 1, División 2. Evite conectar o desconectar ningún componente sin antes desconectar la
alimentación eléctrica, a menos que se sepa que esa zona no presenta riesgos.
A V I S O
La versión con certificación para ubicaciones peligrosas de este producto no cumple los requisitos de la Directiva
94/9/EC (Directiva ATEX).
Cronograma de mantenimiento
En el cronograma de mantenimiento se muestran los intervalos mínimos de las tareas periódicas de
mantenimiento. En las aplicaciones donde el electrodo se ensucia, realice las tareas de
mantenimiento con mayor frecuencia.
Nota: No desmonte la sonda para su mantenimiento o limpieza.
Tarea de mantenimiento Frecuencia mínima recomendada
Limpiar el sensor 90 días
Inspección del sensor en busca de daños 90 días
Calibración del sensor Según lo recomendado por su sistema de control de
calidad o entes regulatorios locales
Limpiar el sensor
Limpie la parte exterior del sensor con un paño suave y húmedo.
Nota: Si debe retirar la cápsula del sensor para limpiarla, no exponga directamente la parte interior de la cápsula a
la luz solar durante un período de tiempo prolongado.
Configuración y cambio del intervalo de limpieza
En función de las condiciones de la aplicación del sensor, los intervalos de tiempo que transcurren
entre las limpiezas del sensor manual pueden ser menores o mayores. El intervalo de limpieza
predeterminado es de 0 días. Para cambiar el intervalo, consulte los pasos de este procedimiento.
Español
25
1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el
sensor]>CONFIGURACIÓN>CLEANING INTERVAL (Intervalo de limpieza).
2. Cambie el valor mostrado según sea necesario. Confirme el cambio.
Para desactivar el intervalo de limpieza, establezca el valor en "0".
Sustitución de la cápsula del sensor
A D V E R T E N C I A
Posible riesgo de explosión. La cápsula de configuración del sensor no se ha evaluado para ser
utilizada en ubicaciones peligrosas.
Junto con las instrucciones de instalación se suministran cápsulas para el sensor y cápsulas de
configuración de repuesto. Para cambiar la cápsula, consulte las instrucciones suministradas.
Después de instalar la nueva cápsula del sensor, asegúrese de que el número de lote de la cápsula
del sensor es el mismo número de lote de la cápsula del sensor es el mismo número que se puede
leer por Modbus. El sensor utiliza la información de calibración de la cápsula del sensor.
Para obtener un mejor rendimiento y precisión, sustituya la cápsula del sensor:
Cada dos añoso con mayor frecuencia si es necesario.
Cuando en las inspecciones periódicas se detecte una erosión importante en la cápsula del
sensor.
Solución de problemas
Menú de prueba y diagnóstico
En el menú de prueba y diagnóstico se muestra la información actual e histórica relativa al sensor
LDO.
Para acceder al menú de prueba y diagnóstico, vaya a MENU (Menú)>CONFIGURACIÓN DEL
SENSOR>[Seleccione el sensor]>MANTENIMIENTO.
Consulte la Tabla 5.
Tabla 5 Menú Mantenimiento
Opción Descripción
Información del sensor Versión de software: muestra la versión de software instalada
Programa de arranque: muestra la versión de programa de arranque instalada
Versión de controlador: muestra la versión de controlador de software instalada
Sensor cap lot code (Código
de lote de la cápsula del
sensor)
Muestra el lote de fabricación de la cápsula del sensor.
Número de serie Número de serie del sensor
Corrección de ganancia Ajusta el valor de ganancia de la calibración.
Intervalo: de 0,50 a 2,00
Corrección de
compensación
Ajusta el valor de desvío de la calibración (mg/l o ppm).
Intervalo: de -3,00 a +3,00
Diagnósticos de fase Muestra la fase de las longitudes de onda totales, rojas y azules. Actualiza una
por segundo.
Diagnósticos de amplitud Muestra la amplitud de las longitudes de onda rojas y azules. Actualiza una por
segundo.
26 Español
Tabla 5 Menú Mantenimiento (continúa)
Opción Descripción
Days remaining to clean
(Días hasta próxima
limpieza)
Muestra el número de días que quedan hasta la próxima limpieza manual
programada.
Sensor life (Duración del
sensor)
Muestra el número de días que quedan hasta la próxima sustitución programada
de la cápsula del sensor..
Lista de errores
Si se produce un error, la lectura de la pantalla de medición se iluminará. Los ajustes del controlador
determinan la conducta de la salida. Para obtener información detallada, consulte el manual del
controlador.
Para ver los errores del sensor actual, vaya a MENU (Menú)>DIAGNÓSTICOS DEL
SENSOR>[Seleccione el sensor]>LISTA DE ERRORES. Consulte la Tabla 6.
Tabla 6 Lista de errores del sensor LDO
Error Posible causa Resolución
Amplitud roja muy baja. (El valor es
inferior a 0,01)
o
Amplitud azul muy baja. (El valor es
inferior a 0,01)
La cápsula del sensor no está
instalada o no se ha instalado
correctamente.
Retire la cápsula del sensor y
vuélvala a instalar.
El recorrido de la luz se ha
bloqueado en la cápsula del
sensor.
Inspeccione el interior de la
cápsula y de la lente del sensor.
El sensor no funciona
correctamente.
Asegúrese de que el LED se
ilumina. Póngase en contacto
con el fabricante.
Lista de advertencias
Cuando el icono de advertencia se ilumina (sc100 y sc200) o cuando el color de la pantalla cambia a
amarillo (sc1000), aparece un mensaje en la parte inferior de la pantalla de medición. En el sc1000,
el color de la pantalla se cambia a amarillo para mostrar una advertencia. Para ver las advertencias
del sensor actual, vaya a MENU (Menú)>DIAGNÓSTICOS DEL SENSOR>[Seleccione el
sensor]>LISTA DE ADVERTENCIAS. Consulte la Tabla 7.
Tabla 7 Lista de advertencias del sensor
Advertencia Definición Resolución
Error de configuración
de EEPROM
El almacenamiento se ha dañado. Los
valores se han establecido a los valores
predeterminados de fábrica.
Póngase en contacto con la asistencia
técnica.
Error de EEPROM
Temperatura <0 °C La temperatura del proceso se encuentra
por debajo de 0 °C (32 °F).
Aumente la temperatura del proceso o
deténgalo hasta que la temperatura se
encuentre dentro del intervalo del sensor
indicado en las especificaciones.
Temperatura >50 °C La temperatura del proceso se encuentra
por encima de 50 °C (120 °F).
Disminuya la temperatura del proceso o
deténgalo hasta que la temperatura se
encuentre dentro del intervalo del sensor
indicado en las especificaciones.
Amplitud roja muy baja. El valor cae por debajo de 0,03. Consulte Lista de errores en la página 27 .
Amplitud roja muy alta. El valor es superior a 0,35. Póngase en contacto con la asistencia
técnica.
Español 27
Tabla 7 Lista de advertencias del sensor (continúa)
Advertencia Definición Resolución
Amplitud azul muy baja. El valor se encuentra por debajo de 0,03. Consulte la Lista de errores
en la página 27.
Amplitud azul muy alta. El valor es superior a 0,35. Póngase en contacto con la asistencia
técnica.
Sensor cap lot code
missing. (Falta el código
de lote de la cápsula del
sensor.)
El código de la cápsula del sensor se ha
dañado. Se ha restablecido
automáticamente el código con los
códigos predeterminados del lote y la
cápsula.
Finalice el procedimiento de la cápsula de
configuración del sensor. Si no hay
ninguna cápsula de configuración
disponible para la cápsula del sensor,
póngase en contacto con la asistencia
técnica.
Lista de eventos
La lista de eventos guarda un registro de los cambios en la forma en la que el sensor registra los
datos. Para ver los eventos del sensor, vaya a MENU (Menú)>DIAGNÓSTICOS DEL
SENSOR>[Seleccione el sensor]>EVENT LIST (Lista de eventos).
Consulte la Tabla 8.
Tabla 8 Lista de eventos del sensor
Evento Descripción
Altitude/Pressure unit change (Cambio de
unidad de altitud/presión)
Se han modificado las unidades de la presión atmosférica o de
la altitud.
Altitude/Pressure change (Cambio de
altitud/presión)
Se ha modificado el valor de la altitud o de la presión
atmosférica.
Temperature change (Cambio de
temperatura)
Se han modificado las unidades de la temperatura.
Unit change (Cambio de unidad) Se ha modificado una unidad nueva de medición.
Salinity change (Cambio de salinidad) Se ha modificado el valor de salinidad.
Restablecimiento Se ha restablecido la configuración del sensor a los valores
predeterminados.
Sensor setup change (Cambio de
configuración del sensor)
Se ha modificado la configuración del sensor.
Cleaning interval change (Cambio de
intervalo de limpieza)
Se ha modificado el intervalo de tiempo que transcurre entre las
limpiezas del sensor.
Sensor life change (Cambio de duración del
sensor)
Se ha modificado el intervalo de tiempo que transcurre entre las
sustituciones de la cápsula del sensor.
28 Español
Fonctionnement
Configuration du capteur
Utilisez le menu Configuration pour saisir les informations d'identification du capteur et modifier les
options de traitement et de stockage des données.
Veuillez consulter le manuel d'utilisation pour des informations sur l'installation du capteur.
Assurez-vous que les valeurs du menu Configuration soient conformes à l'application.
1. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >CONFIGURATION.
2. Sélectionnez une option, puis appuyez sur ENTER (ENTREE). Le tableau ci-dessous présente
les options disponibles.
Option Description
Nom Modifie le nom correspondant au capteur en haut de l'écran de mesure. Le nom est
limité à 10 caractères avec n'importe quelle combinaison de lettres, chiffres, espaces ou
ponctuation.
Unité Température : définit les unités de température en °C (valeur par défaut) ou °F.
Mesure : définit les unités de mesure en mg/L, ppm ou %.
Altitude/pression : définit l'altitude en m ou ft, ou les unités de pression atmosphérique
en mmHg ou torr. (Valeur par défaut = 0 pied.)
Alt./Pression Saisissez la valeur d'altitude ou de pression atmosphérique. Il est nécessaire que cette
valeur soit précise afin d'effectuer les mesures de saturation en pourcentage et
l'étalonnage dans l'air. (Valeur par défaut = 0 pied.)
Salinité Saisissez la valeur de salinité. Plage de salinité : 0 à 250 parties par milliers (‰).
(Valeur par défaut = 0 pied.)
Moyenne du signal Définissez l'intervalle de temps pour la moyenne du signal en secondes.
Intervalle de nettoyage Définissez l'intervalle de temps pour le nettoyage manuel du capteur en jours. (Valeur
par défaut = 0 jour. Une valeur de 0 jour désactive l'intervalle de nettoyage.)
Réinitialiser l'intervalle
de nettoyage
Définissez le dernier intervalle de nettoyage enregistré comme intervalle de temps.
Intervalle de
l'enregistreur de
données
Définit l'intervalle de temps pour l'enregistrement des données dans le journal des
données ; 0,5, 1, 2, 5, 10, 15 (par défaut), 30, 60 minutes.
Réinitialiser Restaure les valeurs par défaut des options de configuration du capteur. Les réglages
de pente et de décalage ne sont pas affectés.
Saisie de la valeur de pression atmosphérique
Le réglage par défaut pour la pression atmosphérique (de l'air) est 0 pied, soit le niveau de la mer.
Pour modifier la valeur par défaut, procédez comme suit. Il est possible d'ajuster la pression d'air à
l'aide d'une valeur d'altitude ou d'unités de pression (recommandée).
Remarque : La précision de la pression de l'air est essentielle pour l'étalonnage de l'air saturé. Utilisez toujours la
valeur de pression absolue, et non la valeur ajustée. Si vous ne connaissez pas la valeur de pression d'air absolue,
utilisez l'altitude exacte de l'endroit où se trouve le capteur.
1. Allez dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >CONFIGURATION >CHOIX
UNITES >PRESS. AIR/ALT.
2. Sélectionnez une des unités suivantes :
Option Description
Altit. (pied) Pied (foot) : unité de mesure anglo-saxonne de l'altitude
Français 29
Option Description
Altit. (mètre) Mètre : unité de mesure de l'altitude
Pression d'air mmHg Millimètres de mercure : unité de mesure de la pression d'air absolue
Pression d'air torr Unité de mesure de pression d'air absolue
3. Confirmez la sélection. L'écran de saisie de valeur affiche les unités sélectionnées.
4. Saisissez la valeur et confirmez.
Saisie d'une valeur de correction de la salinité
Il est possible que la valeur DO affichée par les mesures d'oxygène dissous des échantillons salins
soit très différente de la valeur DO réelle. Pour compenser l'effet des sels dissous dans un
échantillon, saisissez un facteur de correction de la salinité.
Remarque : Si vous n'êtes pas certain du taux de salinité du fluide, renseignez-vous auprès des ingénieurs du site
de traitement.
1. A l'aide d'un conductimètre, mesurez la conductivité de l'échantillon en mS/cm à la température
de référence de 20 °C.
2. Aidez-vous du Tableau 1 pour estimer le facteur de correction de la salinité en fonction de la
saturation en parties par millier (‰).
Remarque : La concentration en ion chlorure, exprimée en g/kg, indique la chlorinité de l'échantillon. Le taux
de salinité est calculé selon la formule suivante : salinité = 1,80655 x chlorinité.
Il est possible de calculer le taux de salinité à l'aide de la relation établie dans la section 2520 B
du document Standard Methods for the Examination of Water and Wastewater.
1
,
3. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le
capteur] >CONFIGURATION >SALINITE.
4. Saisissez le facteur de salinité et confirmez votre saisie.
Tableau 1 Saturation de salinité (‰) en fonction de la valeur de conductivité (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
1
Standard Methods for the Examiniation of Water and Wastewater, 20e édition. Editeurs : Lenore
S. Clesceri, Arnold E. Greenberg et Andrew D. Eaton, p. 2-48-2-29 (1998). Le rapport entre
chlorinité et solubilité de l'oxygène est fourni dans ce même document à la section 4500-O:I p.
4-131.
30 Français
Etalonnage pour les mesures
Le capteur est étalonné en usine conformément aux spécifications. Le fabricant recommande de
procéder à l'étalonnage à la fréquence préconisée par les organismes de contrôle. Si l'étalonnage
est nécessaire, assurez-vous du fonctionnement stabilisé du capteur avant de procéder à
l'étalonnage. Ne procédez pas à l'étalonnage du capteur lors de son installation.
Le Tableau 2 présente les options d'étalonnage.
Tableau 2 Options d'étalonnage
Option Désignation
Etalonnage à l'air libre Méthode d'étalonnage recommandée. Cet étalonnage modifie la pente.
Etalonnage Etalonnage par comparaison avec un appareil de mesure d'oxygène dissous portable.
Cet étalonnage modifie le décalage.
Réinit. étal. Rétablit les valeurs de gain d'étalonnage (pente) et de décalage par défaut ; gain par
défaut = 1,0, décalage par défaut = 0,0
Etalonnage à l'air libre
Remarques à l'intention de l'utilisateur :
Assurez-vous que le sachet utilisé pour l'étalonnage contient bien de l'eau.
Assurez-vous que le joint placé entre le sachet d'étalonnage et le corps du capteur est bien serré.
Avant de procéder à l'étalonnage, assurez-vous que le capteur est bien sec.
Assurez-vous que le réglage de pression d'air et d'altitude est approprié à l'emplacement choisi
pour effectuer l'étalonnage.
Attendez que la température du capteur corresponde à la température de l'emplacement du
sachet d'étalonnage. Jusqu'à 15 minutes peuvent être nécessaires pour réduire un écart de
température important entre le fluide traité et l'emplacement choisi pour l'étalonnage.
1. Sortez le capteur du fluide traité. Nettoyez le capteur à l'aide d'un chiffon humide.
2. Placez l'intégralité du capteur dans un sachet d'étalonnage contenant 25 à 50 ml d'eau. Veillez à
ce que la capsule du capteur n'entre pas en contact avec l'eau du sachet d'étalonnage et ne
comporte aucune goutte d'eau.
3. Resserrez le sac autour du corps du capteur à l'aide d'un ruban adhésif, d'une ficelle ou de votre
main.
4. Avant de procéder à l'étalonnage, laissez le capteur se stabiliser pendant 15 minutes. Pendant la
stabilisation, conservez le sachet d'étalonnage à l'abri du soleil.
5. Assurez-vous que le réglage actuel absolu de pression d'air ou d'altitude est correctement
configuré.
Remarque : le fabricant recommande l'utilisation de la valeur de pression d'air réelle ou absolue.
6. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >ETALONNAGE >ETALON.
A L'AIR
7. Sélectionnez l'option de sortie du signal pendant l'étalonnage :
Option Description
Actif L'instrument envoie la valeur de sortie mesurée pendant la procédure d'étalonnage.
Mémorisation La valeur de sortie du capteur est maintenue à la dernière valeur mesurée pendant la
procédure d'étalonnage.
Transfert Une valeur prédéfinie est fournie pendant l'étalonnage. Consultez le manuel d'utilisation du
transmetteur pour changer la valeur prédéfinie.
Français 31
8. Le transmetteur indiquera « Placer l'ensemble du capteur dans le sac avec l'eau ». Attendez que
la valeur se stabilise. Appuyez sur ENTER (ENTREE) pour accepter la valeur stable. Sinon,
laisser continuer l'étalonnage jusqu'à l'affichage de « La tâche a été réalisée avec succès ».
9. Une fois le capteur étalonné, placez-le dans le fluide traité. Appuyez sur ENTER (ENTREE).
Figure 1 Procédure d'étalonnage à l'air
Si la valeur ne se stabilise pas, l'écran affiche un message d'erreur précédé de la mention « Unable
to Calibrate » (Etalonnage impossible). Le Tableau 3 présente les messages d'erreur et les
résolutions des problèmes d'étalonnage.
Tableau 3 Messages relatifs à l'étalonnage à l'air
Message Description Résolution
Echec de l'étalonnage ! La correction
de gain est trop élevée.
La valeur de gain calculée est trop
élevée.
Procédez à nouveau à
l'étalonnage.
Echec de l'étalonnage ! La correction
de gain est trop faible.
La valeur de gain calculée est trop
faible.
Procédez à nouveau à
l'étalonnage.
Echec de l'étalonnage ! Instable La valeur ne s'est pas stabilisée dans le
délai maximal d'étalonnage.
Procédez à nouveau à
l'étalonnage.
Etalonnage par comparaison
Cette méthode d'étalonnage nécessite un autre capteur connecté à un appareil de mesure portable.
1. Plongez cet autre capteur dans le fluide. Placez le second capteur aussi près que possible du
premier.
2. Attendez la stabilisation de la valeur d'oxygène dissous.
3. Sur le transmetteur pour le premier capteur, allez dans MENU >PROGR.
CAPTEUR >[Sélectionner le capteur] >ETALONNAGE >ETALONNAGE.
4. Sélectionnez l'option de sortie du signal pendant l'étalonnage :
Option Description
Actif L'instrument envoie la valeur de sortie mesurée pendant la procédure d'étalonnage.
Mémorisation La valeur de sortie du capteur est maintenue à la dernière valeur mesurée pendant la
procédure d'étalonnage.
Transfert Une valeur prédéfinie est fournie pendant l'étalonnage. Consultez le manuel d'utilisation du
transmetteur pour changer la valeur prédéfinie.
32 Français
5. Le transmetteur affiche les éléments suivants :
« La lecture est-elle stable ? »
La mesure d'oxygène dissous actuelle
La mesure de température actuelle
6. Une fois la mesure stable, appuyez sur ENTER (ENTREE). Un écran de saisie s'affiche.
Remarque : la mesure se stabilise en général au bout de 2 ou 3 minutes.
Si la valeur ne se stabilise pas, l'écran affiche un message d'erreur précédé de la mention « Unable
to Calibrate » (Etalonnage impossible). Le Tableau 4 présente les messages d'erreur et les
résolutions des problèmes d'étalonnage.
Tableau 4 Messages d'erreur d'étalonnage par échantillon
Message Description Résolution
Echec de l'étalonnage ! Le
décalage est trop élevé.
La valeur de décalage calculée est trop
élevée.
Procédez à nouveau à
l'étalonnage.
Echec de l'étalonnage ! Le
décalage est trop faible.
La valeur de décalage calculée est trop
faible.
Procédez à nouveau à
l'étalonnage.
Echec de l'étalonnage ! Instable La valeur ne s'est pas stabilisée dans le
délai maximal d'étalonnage.
Procédez à nouveau à
l'étalonnage.
Quitter la procédure d'étalonnage
1. Pendant l'étalonnage, appuyez sur la touche BACK (RETOUR). Trois options apparaissent :
Option Description
Annuler Arrête l'étalonnage. Un nouvel étalonnage devra repartir du début.
Revenir à
l'étalonnage
Permet de reprendre l'étalonnage en cours.
Quitter Quitte temporairement l'étalonnage. L'étalonnage se poursuit en arrière-plan,
permettant l'accès à d'autres menus. Il est possible de démarrer un étalonnage pour
un deuxième capteur (le cas échéant). Pour revenir à l'étalonnage, appuyez sur la
touche MENU et sélectionnez Sensor Setup (Config capteur), [Sélectionnez le
capteur].
2. Sélectionnez une des options. Validez.
Réinitialisation des valeurs d'étalonnage par défaut
Il est possible de réinitialiser les réglages d'étalonnage à l'aide des valeurs par défaut. Les valeurs
de gain et de décalage sont alors définies sur 1 et 0, respectivement.
1. Allez dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >ETALONNAGE >REINIT.
ETAL.
2. Un message de confirmation s'affiche. Confirmez la réinitialisation du capteur à l'aide de la
courbe d'étalonnage par défaut.
Maintenance
D A N G E R
Dangers multiples. Seul le personnel qualifié doit effectuer les tâches détaillées dans cette section du
document.
Français 33
D A N G E R
Risque d'explosion. Ne branchez ni ne débranchez aucun composant électrique ou circuit sur
l'équipement avant de vous être assuré que l'alimentation a été coupée et que l'emplacement est
sécurisé.
D A N G E R
Risque d'explosion. Tout changement de composant est susceptible d'avoir une incidence sur la
conformité Classe 1, Division 2. Ne remplacez jamais un composant avant de vous être assuré que
l'alimentation a été coupée et que l'emplacement est sécurisé.
A V I S
La version de ce produit certifiée pour les environnements dangereux n'est pas conforme à la norme 94/9/EC
(norme ATEX).
Calendrier de maintenance
Le calendrier de maintenance indique la fréquence minimum des tâches de maintenance régulières.
Effectuer les opérations d'entretien plus fréquemment avec des applications entraînant une
contamination de l'électrode.
Remarque : ne démontez pas la sonde pour la maintenance ou le nettoyage.
Tâche de maintenance Fréquence minimum recommandée
Nettoyage du capteur 90 jours
Inspection du capteur 90 jours
Etalonnage du capteur Conformément aux recommandations des organismes
de contrôle
Nettoyage du capteur
Nettoyez la surface du capteur à l'aide d'un chiffon doux humide.
Remarque : S'il est nécessaire de retirer la capsule du capteur lors du nettoyage, évitez d'exposer l'intérieur de la
capsule aux rayons du soleil pendant une période prolongée.
Définition ou modification de l'intervalle de nettoyage
L'intervalle adéquat entre les nettoyages manuels du capteur peut varier en fonction des conditions
d'utilisation. L'intervalle de nettoyage par défaut est de 0 jour. Pour modifier l'intervalle, procédez
comme suit.
1. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le
capteur] >CONFIGURATION >INTERV NETTOYAGE.
2. Modifiez la valeur affichée. Confirmez la modification.
Pour désactiver l'intervalle de nettoyage, définissez 0 comme valeur.
Remplacement du capuchon du capteur
A V E R T I S S E M E N T
Risque d'explosion. Le capuchon de configuration du capteur n'est pas certifié pour une utilisation en
environnement dangereux.
Des instructions d'installation sont fournies avec les capuchons de configuration et les capuchons de
capteur de rechange. Pour remplacer le capuchon, reportez-vous aux instructions fournies. Une fois
le capuchon du nouveau capteur installé, assurez-vous que le numéro de lot figurant sur le capuchon
du capteur est identique à celui qui est lu par Modbus. Le capteur utilise les informations
d'étalonnage qui figurent sur ce capuchon.
34
Français
Pour bénéficier de performances et d'une précision optimales, remplacez le capuchon du capteur :
Tous les deux ans ;ou plus si nécessaire
Lorsque l'inspection de routine révèle une forte érosion du capuchon du capteur.
Dépannage
Menu de diagnostic et test
Le menu de diagnostic et de test affiche les informations actuelles et consignées relatives au capteur
LDO.
Pour accéder au menu de diagnostic et de test, rendez-vous dans MENU >PROGR.
CAPTEUR >[Sélectionner le capteur] >DIAG/TEST.
Reportez-vous à Tableau 5.
Tableau 5 Menu Diag/Test
Option Description
Informations de capteur Version du logiciel : affiche la version du logiciel installé
Programme de démarrage : indique la version du programme de démarrage
installé
Version du pilote : indique la version du pilote installé
Numéro de lot du bouchon
du capteur
Affiche le lot de fabrication du capuchon du capteur
N° de série Numéro de série du capteur
Corr. gain Permet d'ajuster la valeur de gain d'étalonnage.
Plage : 0,5 à 2
Corr. zéro Permet d'ajuster la valeur de décalage d'étalonnage (mg/l ou ppm).
Plage : -3 à 3
Diag. phase Affiche la phase des longueurs d'onde bleue, rouge et totale. Mise à jour chaque
seconde.
Diagn. amplit. Affiche l'amplitude des longueurs d'onde bleue et rouge. Mise à jour chaque
seconde.
Jours restants avant le
nettoyage
Affiche le nombre de jours avant le prochain nettoyage manuel programmé.
Durée de vie du capteur Affiche le nombre de jours avant le prochain remplacement de capuchon du
capteur programmé..
Liste d’erreurs
En cas d'erreur, la mesure affichée clignote. Le comportement de sortie est déterminé par les
réglages du transmetteur. Pour plus d'informations, reportez-vous au manuel du transmetteur.
Français
35
Pour afficher les erreurs de capteur actuelles, allez dans MENU >DIAGN. CAPTEUR >[Sélectionner
le capteur] >LISTE ERREURS. Reportez-vous à Tableau 6.
Tableau 6 Liste d'erreurs du capteur LDO
Erreur Cause possible Résolution
L'amplitude rouge est trop faible. (La valeur est
inférieure à 0,01)
ou
L'amplitude bleue est trop faible. (La valeur est
inférieure à 0,01)
Le capuchon du capteur n'est
pas installé ou ne l'est pas
correctement.
Retirez le capuchon du
capteur, puis replacez-le.
La trajectoire de la lumière est
bloquée dans le capuchon du
capteur.
Inspectez la lentille et
l'intérieur du capuchon du
capteur.
Le capteur ne fonctionne pas
correctement.
Assurez-vous que le voyant
clignote. Contactez le
fabricant.
Liste d’avertissements
Lorsque l'icône d'avertissement clignote (sc100 et sc200) ou lorsque l'écran devient jaune (sc1000),
un message s'affiche en bas de l'écran. Sur le transmetteur sc1000, l'écran devient jaune lorsqu'un
avertissement est affiché. Pour afficher les avertissements actuels des capteurs, allez dans
MENU >DIAGN. CAPTEUR > [Sélectionner le capteur] >LISTE AVERTIS. Reportez-vous à
Tableau 7.
Tableau 7 Liste d'avertissements du capteur
Avertissement Définition Résolution
Err. progr. EEPR Le stockage est corrompu. Les valeurs
par défaut ont été rétablies.
Contactez l’assistance technique.
Err. res. EEPR
Température < 0 °C La température du fluide est inférieure à
0 °C
Augmentez la température du fluide ou
cessez son utilisation jusqu'à ce que
sa température soit comprise dans la
plage des spécifications du capteur.
Température > 50 °C La température du fluide est supérieure à
50 °C
Diminuez la température du fluide ou
cessez son utilisation jusqu'à ce que
sa température soit comprise dans la
plage des spécifications du capteur.
L'amplitude rouge est trop
faible.
La valeur est inférieure à 0,03 Voir le Liste d’erreurs à la page 35.
L'amplitude rouge est trop
élevée.
La valeur est supérieure à 0,35 Appelez l'assistance technique.
L'amplitude bleue est trop
faible.
La valeur est inférieure à 0,03 Reportez-vous à Liste d’erreurs
à la page 35.
L'amplitude bleue est trop
élevée.
La valeur est supérieure à 0,35 Appelez l'assistance technique.
Numéro de lot du bouchon
de capteur manquant.
Le code du capuchon du capteur est
corrompu. Le code a été
automatiquement réinitialisé à l'aide des
codes de lot et de capuchon par défaut.
Suivez les instructions relatives au
capuchon de configuration du capteur.
Si aucun capuchon de configuration
n'est disponible pour le capuchon du
capteur, contactez l'assistance
technique.
36 Français
Liste d'événements
La liste d'événements consigne les modifications apportées au mode d'enregistrement des données
par le capteur. Pour afficher les événements des capteurs, allez dans MENU >DIAGN.
CAPTEUR >[Sélectionner le capteur] >LISTE EVENEMENTS.
Reportez-vous à Tableau 8.
Tableau 8 Liste d'événements du capteur
Evénement Description
Changement des unités d'altitude/pression Les unités de pression atmosphérique ou d'altitude ont été
modifiées.
Changement d'altitude/pression La valeur de pression atmosphérique ou d'altitude a été modifiée.
Changement de température Les unités de température ont été modifiées.
Changement de l'unité Une nouvelle unité de mesure a été introduite.
Changement de salinité La valeur de salinité a été modifiée.
Réinitialiser Les valeurs par défaut des réglages du capteur ont été rétablies.
Changement de configuration du capteur La configuration du capteur a été modifiée.
Changement d'intervalle de nettoyage L'intervalle entre deux nettoyages du capteur a été modifié.
Changement de la durée de vie du capteur L'intervalle entre deux remplacements du capuchon du capteur a
été modifié.
Français 37
Funzionamento
Configurazione del sensore
Utilizzare il menu Configurazione per inserire i dati di identificazione del sensore e modificare le
opzioni per la gestione e la conservazione dei dati.
Per informazioni sull'installazione del sensore, fare riferimento al manuale utente.
Verificare che tutti i valori del menu Configurazione siano corretti per la specifica applicazione.
1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE.
2. Selezionare un'opzione e premere ENTER. Nella tabella seguente è riportato l'elenco delle
opzioni disponibili.
Opzione Descrizione
Nome Consente di modificare il nome del sensore visualizzato sulla parte superiore della
schermata di misurazione. Il nome è limitato a 10 caratteri in una combinazione qualsiasi
di lettere, numeri, spazi e punteggiatura.
Unità Temperatura - Consente di impostare le unità della temperatura su °C (predefinito) o °F.
Misura - Consente di impostare le unità di misura su mg/l, ppm o %.
Alt/Press - Consente di impostare l'altitudine in metri o piedi, oppure di impostare le unità
della pressione atmosferica in mmHg o torr. (Valore predefinito = 0 piedi)
Alt/Press Consente di immettere il valore dell'altitudine o della pressione atmosferica. Questo
valore deve essere accurato per eseguire le misurazioni di saturazione percentuale e la
calibrazione in aria. (Valore predefinito = 0 piedi)
Salinità Consente di immettere il valore di salinità. Intervallo di salinità: da 0.00 a 250.00 parti per
migliaia (‰). (Valore predefinito = 0)
Media segnale Consente di impostare l'intervallo in secondi per il calcolo della media dei segnali.
Cleaning interval
(Intervallo di pulizia)
Consente di impostare l'intervallo di tempo per la pulizia manuale del sensore in giorni.
(Valore predefinito = 0 giorni. Il valore 0 giorni disabilita l'intervallo di pulizia)
Reset cleaning
interval (Reset
intervallo di pulizia)
Consente di impostare l'intervallo di tempo per la pulizia sull'ultimo valore salvato.
Sen/Interval Consente di impostare l'intervallo di tempo per la memorizzazione dei dati nel registro:
0.5, 1, 2, 5, 10, 15 (predefinito), 30 e 60 minuti.
Ripr config Consente di ripristinare i valori predefiniti configurabili per il sensore. Non modifica
l'impostazione di slope o offset.
Immissione del valore di pressione atmosferica
L'impostazione predefinita per la pressione atmosferica (aria) è di 0 piedi o livello del mare. Per
modificare il valore predefinito eseguire questa procedura. La regolazione della pressione dell'aria si
immette sia come altitudine sia sotto forma di unità di pressione (opzione preferenziale).
Nota: l'accuratezza della pressione dell'aria è essenziale per la calibrazione dell'aria satura. Utilizzare solo la
pressione assoluta e non quella regolata. Se la pressione assoluta non è nota, utilizzare l'altitudine corretta del sito
di installazione.
1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>UNITÀ>PRESS/ALT
ARIA.
2. Selezionare una delle opzioni elencate:
Opzione Descrizione
Alt in piedi Piedi - Unità di misura dell'altitudine
38 Italiano
Opzione Descrizione
Alti in metri Metri - Unità di misura metrica dell'altitudine
Press aria mmHg Millimetri di mercurio - Unità di misura metrica della pressione assoluta
Press aria torr Unità di misura per la pressione assoluta dell'aria
3. Confermare la selezione. La schermata di immissione dei valori visualizzerà le unità selezionate.
4. Immettere il valore e confermare.
Immissione del valore di correzione della salinità
Le misurazioni dell'ossigeno disciolto nei campioni salini possono indicare un valore di OD apparente
che in realtà è molto distante da quello effettivo. Per correggere l'influenza esercitata dai sali disciolti
sul campione, immettere un fattore di correzione della salinità.
Nota: se la presenza o la quantità di salinità nel processo non sono note, rivolgersi al personale tecnico
dell'impianto di trattamento.
1. Per misurare la conduttività del campione in mS/cm ad una temperatura di riferimento di 20 °C
(68 °F), utilizzare un misuratore di conduttività.
2. Per stimare il fattore di correzione della salinità in parti per migliaia (‰) di saturazione, utilizzare
la Tabella 1.
Nota: la concentrazione di ioni di cloruro in g/kg è uguale alla clorinità del campione. La salinità viene calcolata
sulla base della formula seguente: Salinità = 1,80655 × clorinità.
È possibile calcolare la salinità mediante il rapporto riportato nella sezione 2520 B di Standard
Methods for the Examination of Water and Wastewater.
1
,
3. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>SALINITÀ.
4. Immettere il fattore di correzione della salinità e confermare.
Tabella 1 Saturazione di salinità (‰) per valore di conduttività (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
1
Standard Methods for the Examiniation of Water and Wastewater (Metodi standard per l'analisi
di acque e acque reflue), 20esima edizione. Editors Lenore S. Clesceri, Arnold E. Greenberg
and Andrew D. Eaton, pagg. 2-48-2-29 (1998). La relazione fra clorinità e solubilità dell'ossigeno
è riportata nel medesimo documento di riferimento in 4500-O:I pagg. 4-131.
Italiano 39
Calibrazione per le misurazioni
Il sensore viene calibrato dal produttore in base alle specifiche. Il produttore non consiglia di eseguire
la calibrazione a meno che gli enti di regolamentazione non richiedano periodicamente tale
operazione. Se è necessario eseguire la calibrazione, prima di avviarla attendere che il sensore si
stabilizzi nel processo. Non eseguire la calibrazione del sensore in fase di impostazione.
Nella Tabella 2 sono riportate le opzioni per la calibrazione.
Tabella 2 Opzioni di calibrazione
Opzione Descrizione
Aria calibraz Metodo di calibrazione consigliato. Questa calibrazione modifica lo slope.
Curva di Calibrazione tramite confronto con un ossimetro portatile. Questa calibrazione modifica l'offset.
Reimpostaz ca Ripristina il guadagno di calibrazione (slope) e l'offset ai valori predefiniti dal produttore:
guadagno predefinito = 1.0; offset predefinito = 0.0
Aria calibraz
Note per l'utente:
Accertarsi che nella sacca di calibrazione sia presente l'acqua.
Accertarsi che il corpo del sensore sia perfettamente sigillato all'interno della sacca di calibrazione.
Quando si esegue la calibrazione verificare che il sensore sia asciutto.
Accertarsi che l'impostazione della pressione dell'aria/altitudine sia accurata per la posizione di
calibrazione.
Attendere che la temperatura del sensore si stabilizzi su quella della posizione della sacca di
calibrazione. In caso di differenza di temperatura significativa fra il processo e la posizione di
calibrazione, la stabilizzazione può richiedere fino a 15 minuti.
1. Rimuovere il sensore dal processo. Pulire il sensore con un panno bagnato.
2. Inserire tutto il sensore in una sacca di calibrazione con 25-50 ml di acqua. Accertarsi che il
cappuccio del sensore non sia a contatto con l'acqua all'interno della sacca di calibrazione e che
sul cappuccio del sensore non siano presenti gocce d'acqua.
3. Utilizzare un elastico, una fascetta o la mano per creare una tenuta ermetica intorno al corpo del
sensore.
4. Prima di eseguire la calibrazione, attendere 15 minuti in modo che il sensore si stabilizzi. Durante
questa fase di stabilizzazione non esporre la sacca alla luce diretta del sole.
5. Assicurarsi che la pressione assoluta dell'aria o l'altitudine sia configurata correttamente.
Nota: Il produttore consiglia di utilizzare come miglior prassi la pressione assoluta o effettiva dell'aria.
6. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CALIBRAZIONE>ARIA CALIBRAZ.
7. Selezionare l'opzione per il segnale di output durante la calibrazione:
Opzione Descrizione
Attivo Lo strumento invia il valore di output misurato corrente durante la procedura di
calibrazione.
Hold (Memorizza) Il valore di output del sensore viene tenuto al valore misurato corrente durante la
procedura di calibrazione.
Transfer (Trasmetti) Durante la calibrazione viene inviato un valore predefinito. Per modificare il valore
predefinito, fare riferimento al manuale dell'utente del controller.
8. Il controller visualizza "Inserire l'intero sensore nella sacca con acqua.". Attendere che il valore si
stabilizzi. Premere ENTER per accettare il valore stabile. In alternativa, lasciare che la
calibrazione continui finché sul display non viene visualizzato "Attività completata correttamente.
".
9. Dopo aver completato la calibrazione, posizionare il sensore nel processo. Premere ENTER.
40
Italiano
Figura 1 Procedura di calibrazione in aria
Se il valore non si stabilizza, appare la segnalazione "Unable to Calibrate" (Impossibile eseguire la
calibrazione) seguita da un messaggio di errore. Nella Tabella 3 sono riportati i messaggi di errore e
le soluzioni dei problemi di calibrazione.
Tabella 3 Messaggi di errore per la calibrazione in aria
Messaggio Descrizione Risoluzione
Cal non corret Gain alto. Il guadagno calcolato è troppo alto. Ripetere la calibrazione.
Cal non corret Gain inferiore. Il guadagno calcolato è troppo basso. Ripetere la calibrazione.
Cal non corret Instabile Il valore non si è stabilizzato durante il tempo di
calibrazione massimo consentito.
Ripetere la calibrazione.
Calibrazione per confronto
Questo metodo di calibrazione utilizza un sensore alternativo collegato ad un ossimetro portatile.
1. Inserire il sensore alternativo nel processo. Posizionare il secondo sensore il più vicino possibile
al primo.
2. Attendere che il DO valore si stabilizzi.
3. Sul controller del primo sensore, scegliere MENU>SETUP SONDA>[Scelta
sensore]>CALIBRAZIONE>CALIBRAZIONE.
4. Selezionare l'opzione per il segnale di output durante la calibrazione:
Opzione Descrizione
Attivo Lo strumento invia il valore di output misurato corrente durante la procedura di
calibrazione.
Hold (Memorizza) Il valore di output del sensore viene tenuto al valore misurato corrente durante la
procedura di calibrazione.
Transfer (Trasmetti) Durante la calibrazione viene inviato un valore predefinito. Per modificare il valore
predefinito, fare riferimento al manuale dell'utente del controller.
5. Sul controller appare:
"Lett. stabile?"
La misura corrente dell'ossigeno disciolto
La misura corrente della temperatura
6. Quando la misura è stabile, premere ENTER. Sul display apparirà una schermata di immissione.
Nota: la misur in genere si stabilizza in 2-3 minuti.
Italiano
41
Se il valore non si stabilizza, appare la segnalazione "Unable to Calibrate" (Impossibile eseguire la
calibrazione) seguita da un messaggio di errore. Nella Tabella 4 sono riportati i messaggi di errore e
le soluzioni dei problemi di calibrazione.
Tabella 4 Messaggi di errore della calibrazione campione
Messaggio Descrizione Risoluzione
Cal non corret Offset alto L'offset calcolato è troppo alto. Ripetere la calibrazione.
Cal non corret Offset basso L'offset calcolato è troppo basso. Ripetere la calibrazione.
Cal non corret Instabile Il valore non si è stabilizzato durante il tempo di
calibrazione massimo consentito.
Ripetere la calibrazione.
Uscita dalla procedura di calibrazione
1. Durante la calibrazione, premere il tasto BACK (INDIETRO). Sono mostrate tre opzioni:
Opzione Descrizione
Annul Interrompe la calibrazione. Una nuova calibrazione deve riprendere dall'inizio.
Ritorno cal Torna alla calibrazione corrente.
Uscita Esce temporaneamente dalla calibrazione. Mentre la taratura è in corso in background è
possibile accedere ad altri menu. È possibile avviare la calibrazione per un secondo sensore
(ove presente). Per tornare alla calibrazione, premere il tasto MENU e selezionare Sensor
Setup (Impostazione sensore), [Selezionare il sensore].
2. Selezionare una delle opzioni. Confermare.
Ripristino delle impostazioni predefinite di calibrazione
Le impostazioni di calibrazione possono essere ripristinate ai valori predefiniti. I valori di guadagno e
offset vengono impostati rispettivamente su 1.0 e 0.0.
1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CALIBRAZIONE>REIMPOSTAZ CA.
2. Sul display apparirà un messaggio di conferma. Confermare per reimpostare la curva di
calibrazione del sensore ai valori di fabbrica.
Manutenzione
P E R I C O L O
Pericoli multipli. Gli interventi descritti in questa sezione del documento devono essere eseguiti solo da
personale qualificato.
P E R I C O L O
Rischio di esplosione. Non collegare o scollegare alcun componente o circuito elettrico
dall'apparecchiatura senza aver prima interrotto l'alimentazione oppure solo nel caso in cui l'area sia
ritenuta non pericolosa.
P E R I C O L O
Rischio di esplosione. La sostituzione di componenti potrebbe ridurre l'idoneità per Class 1, Division
2. Non sostituire alcun componente senza aver prima interrotto l'alimentazione e solo nel caso in cui
l’area sia ritenuta non pericolosa.
A V V I S O
La versione certificata per aree pericolose di questo prodotto non è conforme ai requisiti della Direttiva 94/9/CE
(Direttiva ATEX).
42 Italiano
Schema per le operazioni di manutenzione
Il programma di manutenzione indica gli intervalli minimi per gli interventi di manutenzione di routine.
Eseguire le attività di manutenzione più frequentemente per applicazioni che causano sporcamento
degli elettrodi.
Nota: per eseguire gli interventi di manutenzione o pulizia non smontare la sonda.
Intervento di manutenzione Frequenza minima consigliata
Pulizia del sensore 90 giorni
Verifica della presenza di danni al sensore 90 giorni
Calibrazione del sensore Come specificato dagli enti di regolamentazione
Pulizia del sensore
Pulire la superficie esterna del sensore con un panno morbido bagnato.
Nota: se per eseguire la pulizia è necessario rimuovere il cappuccio, non esporre la parte interna dello stesso alla
luce diretta del sole per periodi prolungati.
Impostazione o modifica dell'intervallo di pulizia
Le condizioni della specifica applicazione possono imporre intervalli più brevi o più lunghi fra le
pulizie manuali del sensore. L'intervallo predefinito di pulizia è di 0 giorni. Per modificare l'intervallo,
eseguire questa procedura.
1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>CLEANING
INTERVAL (INTERVALLO DI PULIZIA).
2. Modificare il valore secondo necessità. Confermare la modifica.
Per disattivare l'intervallo di pulizia, impostare il valore su '0'.
Sostituzione del cappuccio del sensore
A V V E R T E N Z A
Potenziale pericolo di esplosione. Il cappuccio per l'impostazione del sensore non è classificato per
l'uso in aree pericolose.
I cappucci di ricambio e quelli da utilizzare per l'impostazione del sensore vengono forniti con le
istruzioni di installazione. Per la sostituzione del cappuccio, vedere le istruzioni incluse. Dopo aver
installato il nuovo cappuccio del sensore, accertarsi che il numero di lotto sul cappuccio del sensore
sia lo stesso numero di lotto letto da Modbus. Il sensore utilizza le informazioni di calibrazione inviate
dal cappuccio del sensore.
Per ottenere prestazioni e accuratezza ottimali, sostituire il cappuccio del sensore:
Ogni due anni, o più spesso se necessario
Nel caso in cui durante un'ispezione di routine si riscontrino segni significativi di erosione
Individuazione ed eliminazione dei guasti
Menu di verifica e diagnostica
Il menu di verifica e diagnostica mostra le informazioni correnti e storiche del sensore LDO.
Per accedere al menu di verifica e diagnostica, scegliere MENU>SETUP SONDA>[Scelta
sensore]>DIAG/TEST.
Italiano
43
Fare riferimento a Tabella 5.
Tabella 5 Menu Diag/Test
Opzione Descrizione
Info sonda Versione SW - Visualizza la versione installata del software
Boot program (Programma di avvio) - Visualizza la versione installata del
programma di avvio
Vers. guida - Visualizza la versione installata del driver software
Sensor cap lot code (Codice
lotto del tappo sensore)
Visualizza il lotto di produzione del cappuccio del sensore
Numero serie Numero di serie del sensore
Correzione gain Regolare il valore di guadagno della calibrazione.
Intervallo: da 0.50 a 2.00
Corr offset Regolare il valore di offset della calibrazione (mg/l o ppm).
Intervallo: da –3.00 a +3.00
Fase diagnosi Mostra la fase per le lunghezze d'onda rossa, blu e totale. Si aggiorna ogni
secondo.
Diagn estesa Mostra l'ampiezza per le lunghezze d'onda rossa e blu. Si aggiorna ogni secondo.
Days remaining to clean
(Giorni alla pulizia)
Mostra il numero di giorni residui fino alla successiva pulizia manuale
programmata.
Sensor life (Durata sensore) Mostra il numero di giorni residui fino alla successiva sostituzione programmata
del cappuccio del sensore..
Elenco errori
Se si verifica un errore, il valore sulla schermata di misurazione lampeggia. Il comportamento
dell'output dipende dalle impostazioni del controller. Per maggiori informazioni, fare riferimento al
manuale del controller.
Per visualizzare gli errori correnti del sensore, scegliere MENU>DIAGN. SONDA>[Scelta
sensore]>LISTA ERRORI. Fare riferimento a Tabella 6.
Tabella 6 Elenco degli errori del sensore LDO
Errore Possibile causa Risoluzione
Rosso esteso bass (Il valore è inferiore a
0.01)
o
Blue esteso basso (Il valore è inferiore a
0.01)
Il cappuccio del sensore è
montato in modo errato o assente.
Rimuovere il cappuccio del
sensore e rimontarlo.
Il percorso del fascio luminoso è
bloccato dal cappuccio del
sensore.
Esaminare l'interno del
cappuccio e della lente del
sensore.
Il sensore non funziona
correttamente.
Verificare che il LED
lampeggi. Rivolgersi al
produttore.
Elenco avvisi
Quando l'icona di avviso lampeggia (sc100 ed sc200) o quando lo schermo diventa giallo (sc1000),
viene visualizzato un messaggio nella parte inferiore della schermata di misurazione. Sui controller
sc1000 la schermata diventa gialla per segnalare un avviso. Per visualizzare gli avvisi correnti del
44
Italiano
sensore, scegliere MENU>DIAGN. SONDA>[Scelta sensore]>LISTA AVVISI. Fare riferimento a
Tabella 7.
Tabella 7 Elenco degli avvisi del sensore
Avviso Definizione Risoluzione
Err impost EE Memoria danneggiata. I valori sono stati
impostati su quelli predefiniti.
Rivolgersi al servizio di assistenza tecnica.
Err EE RISERV
Temp < 0 °C La temperatura del processo è inferiore a
0 °C (32 °F)
Aumentare la temperatura del processo o
non utilizzare fino a quando la temperatura
non rientra nell'intervallo di specifica del
sensore.
Temp > 50 °C La temperatura del processo è superiore
a 50 °C (120 °F)
Ridurre la temperatura del processo o non
utilizzare fino a quando la temperatura non
rientra nell'intervallo di specifica del
sensore.
Rosso esteso bass Il valore scende sotto a 0.03 Fare riferimento a Elenco errori
a pagina 44.
Rosso esteso alto Il valore è superiore a 0.35 Rivolgersi al servizio di assistenza tecnica.
Blue esteso basso Il valore è inferiore a 0.03 Fare riferimento a Elenco errori
a pagina 44.
Blue esteso alto Il valore è superiore a 0.35 Rivolgersi al servizio di assistenza tecnica.
Sensor cap lot code
missing (Codice lotto
del tappo sensore
mancante).
Il codice del cappuccio del sensore è
corrotto. Il codice è stato
automaticamente ripristinato sui codici
predefiniti di cappuccio e lotto.
Completare la procedura di impostazione
del cappuccio del sensore. Se non è
disponibile un cappuccio per
l'impostazione del sensore, rivolgersi al
servizio di assistenza tecnica.
Elenco degli eventi
L'elenco degli eventi è un registro di tutte le modifiche apportate alla modalità in cui il sensore
registra i dati. Per visualizzare gli eventi del sensore, scegliere MENU>DIAGN. SONDA>[Scelta
sensore]>EVENT LIST (ELENCO EVENTI).
Fare riferimento a Tabella 8.
Tabella 8 Elenco degli eventi del sensore
Evento Descrizione
Altitude/Pressure unit change (Modifica unità
alt/aria)
Le unità della pressione atmosferica o dell'altitudine sono state
modificate.
Altitude/Pressure change (Modifica alt/press) Il valore dell'altitudine o della pressione atmosferica è stato
modificato.
Temperature change (Modifica temperatura) Le unità della temperatura sono state modificate.
Unit change (Modifica unità) È stata modificata un'unità di misura.
Salinity change (Modifica salinità) Il valore di salinità è stato modificato.
Ripr config Le impostazioni del sensore sono state ripristinate ai valori
predefiniti.
Sensor setup change (Modifica setup sonda) L'impostazione del sensore è stata modificata.
Cleaning interval change (Modifica intervallo di
pulizia)
L'intervallo di tempo per la pulizia del sensore è stato
modificato.
Sensor life change (Modifica durata sensore) L'intervallo di tempo per la sostituzione del cappuccio del
sensore è stato modificato.
Italiano 45
Bediening
Configureer de sensor
Gebruik het instellingen om identificerende informatie voor de sensor in te voeren en opties voor het
omgaan met gegevens en opslag te wijzigen.
Raadpleeg de gebruikshandleiding voor informatie over de installatie van de sensor.
Zorg ervoor dat alle waarden in het instellingenmenu juist zijn voor de applicatie.
1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>SETTINGS (INSTELLINGEN).
2. Selecteer een optie, ENTER. Een lijst met beschikbare opties wordt weergegeven in
onderstaande tabel.
Optie Omschrijving
Naam Wijzigt de naam die overeenkomt met de sensor bovenaan op het meetscherm. De
naam is beperkt tot 10 karakters en mag bestaan uit een willekeurige combinatie van
letter, cijfers, spaties en interpunctietekens.
Eenheid Temperatuur–Stelt de temperatuureenheid in op °C (standaard) of °F.
Meting–Stelt de meeteenheden in op mg/L, ppm of %.
Hoogte/Druk–Stelt de hoogte in op m of ft of stelt de atmosferische drukeenheden in
op mmHg of torr. (Standaardwaarde = 0 ft)
Hoogte/druk Voer de waarde van de hoogte of atmosferische druk in. Deze waarde moet
nauwkeurig zijn om metingen van het verzadigingspercentage en kalibratie in lucht te
voltooien. (Standaard = 0 ft).
Zoutgehalte Voer de waarde van het zoutgehalte in. Zoutgehalte: 0,00 tot 250,00 delen per
duizend (‰). (Standaardwaarde = 0)
Signaalgemiddelde Stelt het tijdsinterval in op gemiddelde signalen in seconden
Reinigingsinterval Stelt het tijdsinterval in voor handmatige sensorreiniging in dagen (Standaardwaarde
= 0 dagen. Een waarde van 0 dagen schakelt het reinigingsinterval uit.)
Reinigingsinterval
resetten
Stelt het tijdsinterval in op het laatst bewaarde reinigingsinterval
Interval datalogger Stelt het tijdsinterval voor gegevensopslag in de datalogger in—0,5, 1, 2, 5, 10,
15 (standaard), 30, 60 minuten.
Resetten Herstelt de configureerbare standaardwaarden voor de sensor. Wijzigt de instelling
voor helling of offset niet.
Voer de waarde van de atmosferische druk in
De fabrieksinstelling voor atmosferische (lucht)druk is 0 ft of zeeniveau. Om de standaardwaarde te
wijzigen, gebruikt u de stappen in deze procedure. De afstelling voor luchtdruk wordt ingevoerd als
hoogte- of drukeenheden (gewenst).
Opmerking: Nauwkeurige luchtdruk is belangrijk voor verzadigde luchtkalibratie. Gebruik alleen absolute druk,
geen aangepaste. Als de absolute luchtdruk onbekend is, gebruikt u de correcte hoogte voor de locatie.
1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>SETTINGS (INSTELLINGEN)>UNIT (EENHEID)>AIR PRESSURE/ALTITUDE
(LUCHTDRUK/HOOGTE).
2. Selecteer één van de genoemde opties:
Optie Omschrijving
Hoogte ft Feet (voet)—meeteenheid voor hoogte
46 Nederlands
Optie Omschrijving
Hoogte m Meters—metrische eenheid voor hoogtemeting
Luchtdruk mmHg Millimeter kwikdruk—metrische eenheid voor meting van absolute luchtdruk
Luchtdruk torr Meeteenheid voor absolute luchtdruk
3. Bevestig de selectie. Het invoerscherm voor de waarden geeft de geselecteerde units weer.
4. Voer de waarde in en bevestig.
Correctiewaarde van zoutgehalte invoeren
Metingen van opgelost zuurstof in zoutmonsters kunnen een zichtbare DO-waarde aantonen die erg
verschilt van de werkelijke DO-waarde. Om de invloed van opgeloste zouten in een monster te
corrigeren, voert u een correctiefactor voor het zoutgehalte in.
Opmerking: Als de aanwezigheid of hoeveelheid van het zoutgehalte in het proces onbekend is, raadpleegt u het
technisch personeel voor behandelingsfaciliteiten.
1. Gebruik een geleidbaarheidsmeter om de geleidbaarheid van het monster te meten in mS/cm bij
een referentietemperatuur van 20 °C (68 °F).
2. Gebruik Tabel 1 om de correctiefactor van het zoutgehalte in delen per duizend van (‰)
verzadiging te schatten.
Opmerking: De chloride-ionconcentratie in g/kg is gelijk aan het chloorgehalte van het monster. Zoutgehalte
wordt berekend met de formule: Zoutgehalte = 1,80655 × chloorgehalte.
Zoutgehalte kan worden berekend met de relatie in sectie 2520 B van Standard Methods for the
Examination of Water and Wastewater.
1
,
3. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>SETTINGS (INSTELLINGEN)>SALINITY (ZOUTGEHALTE).
4. Voer de correctiefactor van het zoutgehalte in en bevestig.
Tabel 1 Verzadiging van zoutgehalte (‰) per geleidbaarheidswaarde (ms/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
1
Standard Methods for the Examiniation of Water and Wastewater, 20e editie. Editors Lenore S.
Clesceri, Arnold E. Greenberg en Andrew D. Eaton, p. 2-48-2-29 (1998). De relatie tussen
chloorgehalte en de oplosbaarheid van zuurstof wordt gegeven in dezelfde referentie in 4500-O:I
p. 4-131.
Nederlands 47
Kalibratie voor metingen
De sensor is gekalibreerd volgens specificatie in de fabriek. De fabrikant raadt kalibratie af, tenzij
regelmatig vereist door officiële instanties. Als kalibratie is vereist, laat u de sensor in evenwicht
komen met het proces vóór kalibratie. Kalibreer de sensor niet tijdens het instellen.
Tabel 2 toont opties voor kalibratie.
Tabel 2 Kalibratie-opties
Optie Omschrijving
Kalibratie lucht Aanbevolen kalibratiemethode. Deze kalibratie wijzigt de helling.
Kalibratie Kalibratie volgens vergelijking met een handheld DO-meter. Deze kalibratie wijzigt de offset.
Kalibratie resetten Stelt de kalibratiewaarde voor de steilheid (helling) en offset terug naar de
fabrieksinstellingen: standaardwaarde=1,0; standaardoffset=0,0
Kalibratie lucht
Gebruikersopmerkingen:
Zorg ervoor dat er zich water in de kalibratietas bevindt.
Zorg ervoor dat de afdichting tussen de kalibratietas en de behuizing van de sensor goed afdicht.
Zorg ervoor dat de sensor droog is tijdens kalibratie.
Zorg ervoor dat de luchtdruk-/hoogte-instelling nauwkeurig is voor de kalibratielocatie.
Laat de sensortemperatuur voldoende stabiliseren tot de omgevingstemperatuur van de
kalibratietas. Bij een groot temperatuurverschil tussen het proces en de kalibratielocatie kan het
stabiliseren 15 minuten duren.
1. Verwijder de sensor uit het proces. Reinig de sensor met een natte doek.
2. Plaats de gehele sensor in een kalibratietas met 25-50 ml water. Zorg ervoor dat de sensorkap
niet in contact komt met het water in de kalibratietas en dat er zich geen druppels op de
sensorkap bevinden.
3. Gebruik een rubberen ring, binder of hand om een afdichting om de behuizing van de sensor te
creëren.
4. Laat het instrument 15 minuten stabiliseren vóór de kalibratie. Voorkom tijdens stabilisatie direct
zonlicht op de kalibratietas.
5. Zorg ervoor dat de huidige absolute luchtdruk of hoogte juist is geconfigureerd.
Opmerking: De fabrikant beveelt het gebruik van absolute of werkelijke luchtdruk aan als beste
praktijkmethode.
6. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>CALIBRATION (KALIBRATIE)>AIR CALIBRATION (LUCHTKALIBRATIE).
7. Selecteer de optie voor het uitgangssignaal tijdens de kalibratie:
Optie Omschrijving
Actief Het instrument verzendt de actuele uitgangsmeetwaarde tijdens de kalibratieprocedure.
Hold De sensoruitgangswaarde wordt vastgezet op de actuele meetwaarde tijdens de
kalibratieprocedure.
Overzenden Tijdens de kalibratie wordt een vooraf ingestelde waarde verzonden. Raadpleeg de
gebruikershandleiding van de controller om de vooraf ingestelde waarde te wijzigen.
8. De controller toont de melding "Plaats de hele sensor in de tas met water.". Wacht totdat de
waarde stabiel is. Druk op ENTER om de stabiele waarde te accepteren. Laat in plaats daarvan
de kalibratie doorgaan totdat op het display de volgende melding wordt weergegeven: "Taak is
voltooid. ".
9. Als de sensor is gekalibreerd, plaatst u de sensor in het proces. Druk op ENTER.
48
Nederlands
Afbeelding 1 Luchtkalibratieprocedure
Als de waarde niet stabiliseert, wordt op het display "Unable to Calibrate" ("Kalibratie onmogelijk")
weergegeven, gevolgd door een foutmelding. Tabel 3 toont de foutmelding en de oplossing voor
kalibratieproblemen.
Tabel 3 Foutmeldingen van luchtkalibratie
Bericht Omschrijving Oplossing
Kalibratie mislukt! Versterkingscorrectie is
te hoog.
De berekende steilheidswaarde is te hoog. Herhaal de kalibratie.
Kalibratie mislukt! Versterkingscorrectie is
te laag.
De berekende steilheidswaarde is te laag. Herhaal de kalibratie.
Kalibratie mislukt! Instabiel De waarde is niet gestabiliseerd binnen de
maximaal toegestane kalibratietijd.
Herhaal de kalibratie.
Kalibratie via vergelijking
Bij deze kalibratiemethode wordt gebruik gemaakt van een alternatieve sensor die aan een
handheldmeter is bevestigd.
1. Plaats de alternatieve processor in het proces. Plaats de tweede sensor zo dicht mogelijk bij de
eerste sensor.
2. Wacht totdat de DO-waarde stabiel is.
3. Op de controller van de eerste sensor gaat u naar MENU>SENSOR SETUP
(SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>CALIBRATION
(KALIBRATIE)>CALIBRATION (KALIBRATIE).
4. Selecteer de optie voor het uitgangssignaal tijdens de kalibratie:
Optie Omschrijving
Actief Het instrument verzendt de actuele uitgangsmeetwaarde tijdens de kalibratieprocedure.
Hold De sensoruitgangswaarde wordt vastgezet op de actuele meetwaarde tijdens de
kalibratieprocedure.
Overzenden Tijdens de kalibratie wordt een vooraf ingestelde waarde verzonden. Raadpleeg de
gebruikershandleiding van de controller om de vooraf ingestelde waarde te wijzigen.
5. De controller toont:
"Is de meetwaarde stabiel?"
Meting van de huidige opgeloste zuurstof
Nederlands
49
De huidige temperatuurmeting
6. Als de meting stabiel is, drukt u op ENTER. Op het display wordt een invoerscherm
weergegeven.
Opmerking: De meting is doorgaans na 2 tot 3 minuten stabiel.
Als de waarde niet stabiliseert, wordt op het display "Unable to Calibrate" ("Kalibratie onmogelijk")
weergegeven, gevolgd door een foutmelding. Tabel 4 toont de foutmelding en de oplossing voor
kalibratieproblemen.
Tabel 4 Foutmeldingen van monsterkalibratie
Bericht Omschrijving Oplossing
Kalibratie mislukt! Offset is te hoog. De berekende offsetwaarde is te hoog. Herhaal de kalibratie.
Kalibratie mislukt! Offset is te laag. De berekende offsetwaarde is te laag. Herhaal de kalibratie.
Kalibratie mislukt! Instabiel De waarde is niet gestabiliseerd binnen de
maximaal toegestane kalibratietijd.
Herhaal de kalibratie.
Kalibratieprocedure sluiten
1. Tijdens de kalibratie drukt u op de toets TERUG. Er worden drie mogelijkheden getoond:
Optie Omschrijving
Annuleren Stop de kalibratie. Een nieuwe kalibratie moet vanaf het begin starten.
Keer terug naar
kalibratie
Keer terug naar de huidige kalibratie.
Terug Verlaat de kalibratie tijdelijk. Toegang naar andere menu's is toegestaan terwijl de
kalibratie op de achtergrond wordt voortgezet. Een kalibratie voor een tweede sensor
(indien aanwezig) kan worden gestart. Druk op de toets MENU om naar de kalibratie
terug te keren en selecteer Sensor Setup, [Select Sensor].
2. Selecteer één van de opties. Bevestig.
Kalibratiestandaarden resetten
Kalibratie-instellingen kunnen worden teruggezet naar de fabrieksinstellingen. Steilheids- en
offsetwaarden worden respectievelijk ingesteld op 1,0 en 0,0.
1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>CALIBRATION (KALIBRATIE)>RESET CALIBRATION (KALIBRATIE RESETTEN).
2. Op het display wordt een bevestigingsbericht weergegeven. Bevestig om de sensor te resetten
naar de kalibratiecurve van de standaardfabrieksinstellingen.
Onderhoud
G E V A A R
Diverse gevaren. Alleen bevoegd personeel mag de in dit deel van het document beschreven taken
uitvoeren.
G E V A A R
Explosiegevaar. Koppel elektrische componenten of circuits van het apparaat alleen aan of los als de
stroom uitgeschakeld is of als de zone ongevaarlijk is.
50 Nederlands
G E V A A R
Explosiegevaar. Vervanging van componenten kan ertoe leiden dat het apparaat niet meer geschikt is
voor gebruik in omgevingen van klasse 1, divisie 2. Vervang componenten alleen als de stroom
uitgeschakeld is of als de zone ongevaarlijk is.
L E T O P
Deze productversie die gecertificeerd is voor gevaarlijke omgevingen voldoet niet aan de vereisten van de
94/9/EG-Richtlijn (ATEX-richtlijn).
Onderhoudsschema
Het onderhoudsschema toont minimale intervallen voor regelmatige onderhoudstaken. Voer
onderhoudstaken vaker uit voor toepassingen waarbij de elektroden worden vervuild.
Opmerking: Demonteer de sensor niet voor onderhoud of reiniging.
Onderhoudswerk Minimale aanbevolen frequentie
De sensor reinigen 90 dagen
Controleer de sensor op schade 90 dagen
De sensor kalibreren Zoals aanbevolen door officiële instanties
De sensor reinigen
Reinig de buitenkant van de sensor met een zachte, vochtige doek.
Opmerking: Als de sensorkap moet worden verwijderd voor reiniging, voorkom dan langdurig direct zonlicht op de
binnenkant van de kap.
Stel het reinigingsinterval in of wijzig deze
Bij sommige toepassingen is mogelijk een kortere of langere tijdsduur nodig tussen handmatige
sensorreinigingen. Het standaardreinigingsinterval is 0 dagen. Om het interval te wijzigen, raadpleegt
u de stappen van deze procedure.
1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer
sensor)]>SETTINGS (INSTELLINGEN)>CLEANING INTERVAL (REINIGINGSINTERVAL).
2. Wijzig indien nodig de weergegeven waarde. Bevestig de wijziging.
Om het reinigingsinterval uit te schakelen, stelt u de waarde in op '0'.
Sensorkap vervangen
W A A R S C H U W I N G
Mogelijk explosiegevaar. De instelkap van de sensor is niet geschikt voor gebruik in gevaarlijke
omgevingen.
Vervangende sensorkappen en instelkappen worden met de installatie-instructies meegeleverd.
Raadpleeg de bijgeleverde instructies om de kap te vervangen. Nadat de nieuwe sensorkap is
geplaatst, dient u te controleren of het batchnummer op de sensorkap overeenkomt met het
batchnummer dat wordt uitgelezen door Modbus. De sensor gebruikt de kalibratie-informatie uit de
sensorkap.
Voor de beste resultaten en nauwkeurigheid, vervangt u de sensorkap:
Elke twee jaarof vaker indien nodig
Als routine-inspectie aanzienlijke slijtage van de sensorkap aantoont
Nederlands
51
Problemen oplossen
Diagnose- en testmenu
Het menu om te testen en voor diagnostiek toont de huidige en historische informatie over de LDO-
sensor.
Voor toegang tot het diagnose- en testmenu gaat u naar MENU>SENSOR SETUP
(SENSORINSTELLING>[Selecteer sensor]>MAINTENANCE (ONDERHOUD).
Raadpleeg Tabel 5.
Tabel 5 Menu onderhoud
Optie Omschrijving
Sensorinformatie Softwareversie—Toont de geïnstalleerde softwareversie
Bootprogramma— Toont de geïnstalleerde bootversie
Versie stuurprogramma—Toont het geïnstalleerde stuurprogramma van de
software
Partij-ID sensorkap Toont de partijcode van de sensorkap
Serienummer Serienummer van sensor
Versterkingscorrectie Past de kalibratiewaarde voor steilheid aan.
Bereik: 0,50 tot 2,00
Offset-correctie Past de offsetwaarde van de kalibratie aan (mg/l of ppm).
Bereik: –3,00 tot +3,00
Fase-diagnostiek Toont de fase voor totale, rode en blauwe golflengten. Wordt één keer per
seconde bijgewerkt.
Amplitude-diagnostiek Toont de amplitude voor totale, rode en blauwe golflengten. Wordt één keer per
seconde bijgewerkt.
Resterende dagen voor
reiniging
Toont het aantal dagen tot de volgende geplande handmatige reiniging.
Levensduur sensor Toont het aantal dagen tot de volgende geplande vervanging van de sensorkap.
Foutenlijst
Als een fout optreedt, knippert de meetwaarde op het meetscherm. Het uitgangsgedrag wordt
bepaald door controllerinstellingen. Raadpleeg de controllerhandleiding voor details.
Om de huidige sensorfouten weer te geven, gaat u naar MENU>SENSOR DIAGNOSTICS
(SENSORDIAGNOSE)>[Select Sensor (Selecteer sensor)]>ERROR LIST (FOUTENLIJST).
Raadpleeg Tabel 6.
Tabel 6 Foutenlijst voor de LDO-sensor
Foutmelding Mogelijke oorzaak Oplossing
Rode amplitude is te laag. (Waarde is minder dan
0.01)
of
Blauwe amplitude is te laag. (Waarde is minder
dan 0.01)
De sensorkap is niet
aangebracht of onjuist
aangebracht.
Verwijder de sensorkap en
breng deze op nieuw aan.
Het lichtpad wordt in de
sensorkap geblokkeerd.
Controleer de binnenzijde van
de sensorkap en lens.
De sensor functioneert niet
goed.
Zorg ervoor dat de LED
knippert. Neem contact op
met de fabrikant.
52 Nederlands
Waarschuwingslijst
Als het waarschuwingssymbool knippert (sc100 en sc200) of als het scherm geel wordt (sc1000),
verschijnt er een bericht onder in het meetscherm. Op de sc1000 wordt het scherm geel om een
waarschuwing aan te geven. Om de huidige sensorwaarschuwingen weer te geven, gaat u naar
MENU> SENSOR DIAGNOSTICS (SENSORDIAGNOSE)>[Select Sensor (Selecteer
sensor)]>WARNING LIST (WAARSCHUWINGSLIJST). Raadpleeg Tabel 7.
Tabel 7 Sensorwaarschuwingslijst
Waarschuwing Definitie Oplossing
Fout EEPROM-
instellingen
Opslag is corrupt. De waarden zijn
teruggezet naar de
fabrieksinstellingen.
Neem contact op met de technische
ondersteuningsafdeling.
EEPROM-fout
Temperatuur < 0 °C De procestemperatuur is onder 0 °C
(32 °F)
Verhoog de procestemperatuur of stop het
gebruik totdat de procestemperatuur binnen
het gespecificeerde bereik van de sensor ligt.
Temperatuur > 50 °C De procestemperatuur is boven
50 °C (120 °F)
Verlaag de procestemperatuur of stop het
gebruik totdat de procestemperatuur binnen
het gespecificeerde bereik van de sensor ligt.
Rode amplitude is te
laag.
Waarde valt onder 0,03 Raadpleeg Foutenlijst op pagina 52 .
Rode amplitude is te
hoog.
Waarde is groter dan 0,35 Bel de technische ondersteuning.
Blauwe amplitude is te
laag.
Waarde is minder dan 0,03 Raadpleeg Foutenlijst op pagina 52.
Blauwe amplitude is te
hoog.
Waarde is groter dan 0,35 Bel de technische ondersteuning.
Batch-ID sensorkap
ontbreekt.
De code van de sensorkap is corrupt.
De code is automatisch teruggezet
op de standaardcodes van de kap en
partij.
Voltooi de instelprocedure van de sensorkap.
Als er geen instelkap voor de sensorkap
beschikbaar is, neemt u contact op met de
technische ondersteuning.
Eventlijst
De eventlijst houdt een wijzigingenlogboek bij over hoe gegevens door de sensor worden
opgeslagen. Om sensorgebeurtenissen weer te geven, gaat u naar MENU>SENSOR
DIAGNOSTICS (SENSORDIAGNOSE)>[Select Sensor (selecteer sensor)]>EVENT LIST
(EVENTLIJST).
Raadpleeg Tabel 8.
Tabel 8 Eventlijst voor de sensor
Event Omschrijving
Wijziging hoogte/drukeenheid Eenheden van atmosferische druk of hoogte zijn gewijzigd.
Wijziging hoogte/druk De waarde voor hoogte of atmosferische druk is gewijzigd.
Wijziging temperatuur De temperatuureenheden zijn gewijzigd.
Wijziging eenheid Een nieuwe meeteenheid is gewijzigd.
Wijziging zoutgehalte De waarde voor het zoutgehalte is gewijzigd.
Resetten Sensorinstellingen zijn op fabrieksstandaarden ingesteld.
Wijziging sensorinstellingen De instellingen van de sensor zijn gewijzigd.
Nederlands 53
Tabel 8 Eventlijst voor de sensor (vervolg)
Event Omschrijving
Wijziging reinigingsinterval Het tijdsinterval voor sensorreinigingen is gewijzigd.
Wijziging levensduur sensor Het tijdsinterval voor vervanging van de sensorkap is gewijzigd.
54 Nederlands
Betjening
Konfiguration af sensoren
Brug menuen Indstillinger til at indtaste identifikationsoplysninger til sensoren og for at skifte
funktioner til datahåndtering og opbevaring.
Der er flere oplysninger om installation af sensor i brugervejledningen.
Kontroller, at alle værdier i menuen Indstillinger er korrekte til formålet.
1. Gå MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER.
2. Vælg en funktion, og tryk på ENTER. Listen over tilgængelige funktioner vises i tabellen
nedenfor.
Indstilling Beskrivelse
Navn Ændrer det navn, der korresponderer med sensoren øverst på måleskærmbilledet.
Navnet er begrænset til 10 tegn i en vilkårlig kombination af bogstaver, tal, mellemrum
eller tegnsætning.
Enhed Temperatur - Indstiller temperaturenhederne til °C (standard) eller °F.
Mål - Indstiller måleenhederne til mg/L, ppm eller %.
Højde/tryk - Indstiller højden til m eller ft eller indstiller den atmosfæriske trykenhed til
mmHg eller torr. (Standardværdi = 0 ft)
Højde/tryk Indtast værdien for højden eller det atmosfæriske tryk. Denne værdi skal være præcis
for at fuldføre procentvise mætningsmålinger og kalibrering i luft. (Standard = 0 ft).
Salinitet Indstiller værdien for salinitetindhold. Salinitetsinterval: 0,00 til 250,00 dele pr. tusinde
(‰). (Standardværdi = 0)
Signalgennemsnit Indstil tidsintervallet til gennemsnittet for signaler i sekunder.
Rengøringsinterval Indstil tidsintervallet for manuel rengøring af sensoren i dage (standardværdi =
0 dage). En værdi på 0 dage deaktiverer rengøringsintervallet.
Nulstil rengøringsinterval Indstil tidsintervallet til seneste gemte rengøringsinterval.
Log interval Indstiller tidsintervallet for datalagring i dataloggen - 0.5, 1, 2, 5, 10, 15 (standard), 30,
60 minutter.
Reset (Nulstil) Gendanner de standardværdier for sensoren, som kan konfigureres Undgå at ændre
indstillingen for hældning eller forskydning.
Angivelse af værdien for det atmosfæriske tryk
Standardindstillingen for det atmosfæriske (luft)tryk er 0 ft eller havoverfladen. Hvis du vil ændre
standardværdien, skal du følge denne fremgangsmåde. Justeringen af lufttrykket angives som
stigning eller trykenheder (foretrukket).
BEMÆRK: Et præcist lufttryk er afgørende for kalibrering af mættet luft . Anvend kun det absolutte tryk, ikke det
justerede. Hvis det absolutte lufttryk ikke er kendt, skal du bruge den rette stigning for placeringen.
1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>ENHED>LUFTTRYK/HØJDE.
2. Vælg en af de anførte enhedsindstillinger:
Indstilling Beskrivelse
Højde i fod Fod - måleenhed for stigning
Højde i meter Meter - metrisk måleenhed for stigning
Lufttryk mmHg Milimeter kviksølv - metrisk måleenhed for absolut lufttryk
Lufttryk torr Måleenhed for absolut lufttryk
Dansk 55
3. Bekræft valget. Indtastningsskærmbilledet viser de valgte enheder.
4. Indtast værdien , og bekræft.
Angivelse af en korrektionsværdi for salinitetindhold
Målinger af opløst ilt i salinitetprøver kan vise en umiddelbar værdi, der afviger meget fra den faktiske
værdi. Hvis du vil rette påvirkningen af de opløste salte i prøven, skal du angive en korrektionsfaktor
for salinitetindholdet.
BEMÆRK: Hvis forekomsten eller mængden af salinitet i processen er ukendt, skal du henvende dig hos
behandlingsstedets teknikere.
1. Anvend en ledningsevnemåler til at måle ledningsevnen for prøven i mS/cm ved en
referencetemperatur på 20 °C (68 °F).
2. Brug Tabel 1 til at estimere korrektionsfaktoren for salinitetindholdet som mætning i dele pr.
tusinde (‰).
BEMÆRK: Kloridionkoncentrationen i g/kg svarer til kloriniteten i prøven. Salinitetindholdet beregnes med
formularen: Salinitet = 1,80655 x klorinitet.
Saliniteten kan beregnes med forholdet i afsnit 2520 B i standardmetoder for undersøgelse af
vand og spildvand .
1
,
3. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>SALINITET.
4. Angiv korrektionsfaktoren for salinitetindholdet og bekræft.
Tabel 1 Salinitetsmætning (‰) pr. ledningsevneværdi (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
Kalibrering til målinger
Sensoren er kalibreret af fabrikken. Producenten anbefaler ikke kalibrering med mindre det kræves
af myndighederne. Hvis kalibreringen er påkrævet, skal du lade sensoren blive nulstillet i processen,
før kalibreringen udføres. Undgå at kalibrere sensoren under opsætning.
Tabel 2 viser indstillinger for kalibreringen.
1
Standardmetoder for undersøgelse af vand og spildvand , 20. udgave. Redaktører: Lenore S.
Clesceri, Arnold E. Greenberg og Andrew D. Eaton, s. 2-48-2-29 (1998). Forholdet mellem
klorinitet og iltsolubititet er angivet i samme reference i 4500-O:I s. 4-131.
56 Dansk
Tabel 2 Kalibreringsindstillinger
Indstilling Beskrivelse
Luftkalibrering Anbefalet kalibreringsmetode. Denne kalibrering ændrer hældningen.
Kalibrering Kalibrering ved sammenligning med en håndholdt iltmåler. Denne kalibrering ændrer
forskydningen.
Nulstil kalibrering Nulstiller kalibreringens stigning (hældning) og forskydning til standardindstillingen:
standardstigning = 1,0 og standardforskydning = 0,0.
Luftkalibrering
Brugerbemærkninger
Kontroller, at kalibreringstasken indeholder vand.
Kontroller, at forseglingen mellem kalibreringstasken og sensorenheden er tæt.
Kontroller, at sensoren er tør, når den kalibreres.
Kontroller, at indstillingen for lufttryk/stigning er præcis for kalibreringsplaceringen.
Giv tilstrækkelig tid til, at sensortemperaturen kan stabilisere sig til temperaturen for
kalibreringstaskens placering. Er der stor temperaturforskel mellem processen og
kalibreringsplaceringen, kan temperaturstabilliseringen tage op til 15 minutter.
1. Fjern sensoren fra processen. Brug en våd klud til at rense sensoren.
2. Placer hele sensoren i en kalibreringstaske med 25 - 50 ml vand. Kontroller, at sensorhætten ikke
berører vandet inde i kalibreringstasken, og at der ingen vanddråber findes på sensorhætten.
3. Brug en elastik, et bånd eller hånden til at skabe en tæt forsegling omkring sensorenheden.
4. Lad instrumentet stabilisere i 15 minutter, før kalibreringen udføres. Hold kalibreringstasken væk
fra direkte sollys under stabiliseringsprocessen.
5. Kontroller, at det aktuelle absolutte lufttryk eller -stigning er konfigureret korrekt.
BEMÆRK: Producenten anbefaler at anvende absolut eller faktisk lufttryk som bedste praksis.
6. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>LUFTKALIBRERING.
7. Vælg indstillingen for udgangssignal under kalibrering:
Indstilling Beskrivelse
Aktiv Instrumentet sender den aktuelt målte udgangsværdi under kalibreringsprocessen.
Hold Sensorens udgangsværdi fastholdes på den aktuelt målte værdi i løbet af kalibreringsprocessen.
Overfør En forudindstillet værdi sendes under kalibreringen. Se brugerhåndbogen til kontrolenheden for
at ændre den forudindstillede værdi.
8. Kontrolenheden viser "Put the entire sensor in the bag with water.” (Læg hele sensoren i tasken
med vand). Lad værdien stabilisere sig. Tryk på ENTER for at acceptere den stabile værdi.
Alternativt kan kalibreringen fortsætte, indtil displayet viser "Task was succesfully completed. "
9. Når sensoren er kalibreret, skal du føje den til processen. Tryk på ENTER.
Dansk
57
Figur 1 Luftkalibreringsprocedure
Hvis værdien ikke stabiliserer sig, viser displayet "Unable to Calibrate" (Kan ikke kalibrere), efterfulgt
af en fejlmeddelelse. Tabel 3 viser fejlmeddelelsen og løsninger på kalibreringsproblemerne.
Tabel 3 Fejlmeddelelse for luftkalibrering
Meddelelse Beskrivelse Opløsning
Kalibrering mislykkedes!
Forstærkningskorrektion er for høj.
Den beregnede stigningsværdi er for høj. Gentag kalibreringen.
Kalibrering mislykkedes!
Forstærkningskorrektion er for lav.
Den beregnede stigningsværdi er for lav. Gentag kalibreringen.
Kalibrering mislykkedes! Ustabil Værdien stabiliserede sig ikke inden for
den maksimalt tilladte kalibreringstid.
Gentag kalibreringen.
Kalibrering ved hjælp af sammenligning
Denne kalibreringsmetode anvender en alternativ sensor, der er tilsluttet en håndholdt måler.
1. Placer den alternative sensor i processen. Placer den anden sensor så tæt som muligt på den
første sensor.
2. Vent, indtil opløst ilt måleværdien har stabiliseret sig.
3. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>KALIBRERING på
kontrolenheden for den første sensor.
4. Vælg indstillingen for udgangssignal under kalibrering:
Indstilling Beskrivelse
Aktiv Instrumentet sender den aktuelt målte udgangsværdi under kalibreringsprocessen.
Hold Sensorens udgangsværdi fastholdes på den aktuelt målte værdi i løbet af kalibreringsprocessen.
Overfør En forudindstillet værdi sendes under kalibreringen. Se brugerhåndbogen til kontrolenheden for
at ændre den forudindstillede værdi.
5. Kontrolenheden viser:
”Er aflæsningen stabil?”
Den aktuelle måling af opløst ilt
Den aktuelle temperaturmåling
6. Når målingen er stabil, skal du trykke på ENTER. Displayet viser et indtastningsskærmbillede.
BEMÆRK: Målingen vil normalt stabilisere sig i løbet af 2 - 3 minutter.
58
Dansk
Hvis værdien ikke stabiliserer sig, viser displayet "Unable to Calibrate" (Kan ikke kalibrere), efterfulgt
af en fejlmeddelelse. Tabel 4 viser fejlmeddelelsen og løsninger på kalibreringsproblemerne.
Tabel 4 Fejlmeddelelser for prøvekalibrering
Meddelelse Beskrivelse Opløsning
Kalibrering mislykkedes! Forskydning
er for høj.
Den beregnede stigningsværdi er for høj. Gentag kalibreringen.
Kalibrering mislykkedes! Forskydning
er for lav.
Den beregnede stigningsværdi er for lav. Gentag kalibreringen.
Kalibrering mislykkedes! Ustabil Værdien stabiliserede sig ikke inden for den
maksimalt tilladte kalibreringstid.
Gentag kalibreringen.
Afslutning af kalibreringsprocessen
1. Tryk på tasten BACK (TILBAGE) under kalibreringen, Der vises tre funktioner:
Indstilling Beskrivelse
afbryde Stop kalibreringen. En ny kalibrering skal starte forfra.
Vend tilbage til
kalibrering
Vend tilbage til den aktuelle kalibrering.
Afslut Afslut kalibreringen midlertidigt. Adgang til andre menuer er tilladt, mens
kalibreringen fortsætter i baggrunden. Der kan startes en kalibrering for en anden
sensor (hvis forhåndenværende). Tryk på tasten MENU og vælg Sensor Setup
(Sensoropsætning), [Vælg sensor] for at vende tilbage til kalibreringen.
2. Vælg en af indstillingerne. Bekræft.
Nulstilling til kalibreringens standardindstillinger
Kalibreringsindstillingerne kan nulstilles til standardindstillingerne. Stignings- og forskydningsværdier
bliver indstillet henholdsvis til 1,0 og 0,0.
1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>NULSTIL KALIBRERING.
2. Displayet viser en bekræftelse. Kontroller, at sensoren er nulstillet til standardkurven for
kalibrering.
Vedligeholdelse
F A R E
Flere farer. Kun kvalificeret personale må udføre de opgaver, som er beskrevet i dette afsnit i
dokumentet.
F A R E
Eksplosionsfare. Undlad at tilkoble eller frakoble elektriske komponenter eller kredsløb på udstyret,
medmindre der er slukket for strømmen, eller området vides at være ufarligt.
F A R E
Eksplosionsfare. Udskiftning af komponenter kan påvirke egnetheden til klasse 1, sektion 2. Undlad
at udskifte komponenter, medmindre der er slukket for strømmen, og området vides at være ufarligt.
Dansk 59
B E M Æ R K N I N G
Den version af dette produkt, som er klassificeret til farlige placeringer, opfylder ikke kravene ifølge 94/9/EU-
direktivet (ATEX-direktivet).
Vedligeholdelsesplan
Vedligeholdelsesplanen viser minimumintervallerne for de regelmæssige vedligeholdelsesopgaver.
Udfør vedligeholdelsesopgaverne hyppigere for programmer, der forårsager elektrodetilsmudsning.
BEMÆRK: Undgå at skille sensoren ad i forbindelse med vedligeholdelse eller rengøring.
Vedligeholdelsesopgave Anbefalet minimal hyppighed
Rengøring af sensoren 90 dage
Kontrol af sensoren for beskadigelse 90 dage
Kalibrering af sensoren Som anbefalet ifølge myndighederne
Rengøring af sensoren
Rens sensorens yderside med en blød, våd klud.
BEMÆRK: Hvis sensorhætten skal fjernes af hensyn til rengøringen, skal du undgå at udsætte hættens inderside
for direkte sollys i længere tid.
Indstilling eller ændring af rengøringsintervallet
Afhængigt af betingelserne for anvendelsen kan der være behov for kortere eller længere tid mellem
de manuelle sensorrengøringer. Standardintervallet for rengøring er 0 dage. Hvis du vil ændre
intervallet, skal du benytte fremgangsmåden her.
1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>RENGØRINGSINTERVAL.
2. Tilpas den viste værdi efter behov. Bekræft ændringen.
Hvis du vil deaktivere rengøringsintervallet, skal du indstille værdien til '0'.
Udskiftning af sensorhætten
A D V A R S E L
Potentiel eksplosionsfare Sensorhætten i startopsætningen er ikke klassificeret til brug på farlige
placeringer.
Reservesensorhætterne og hætterne i startopsætningen leveres med installationsanvisninger. Se de
medfølgende anvisninger i udskiftning af hætten. Når den nye sensorhætte er installeret, skal du
kontrollere at lot nummeret på sensorhætten svarer til det lot nummer, der læses af Modbus.
Sensoren anvender kalibreringsoplysninger fra sensorhætten.
Udskift sensorhætten for at opnå optimal ydeevne og præcision:
Hvert 2. åreller oftere, hvis det er nødvendigt
Når det regelmæssige eftersyn viser markant slid af sensorhætten
Fejlsøgning
Diagnostik- og testmenu
Diagnostik- og testmenuen viser aktuelle og historiske oplysninger om LDO-sensoren.
Hvis du vil åbne diagnostik- og testmenuen, skal du gå til MENU>SENSOR SETUP>[Vælg
sensor]>VEDLIGEHOLDELSE.
60
Dansk
Se Tabel 5.
Tabel 5 Vedligeholdelsesmenu
Indstilling Beskrivelse
Sensorinformation Softwareversion - viser den installerede softwareversion
Startprogram - viser det installerede startprogran
Driverversion - viser den installerede driverversion
Partikode for sensorhætte Viser sensorhættens produktionsparti
Serienummer Sensors serienummer
Forstærkningskorrektion Juster kalibreringens stigningsværdi.
Område: 0,50 til 2,00
Offset korrektion Juster kalibreringens forskydningsværdi (mg/L eller ppm)
Område: –3,00 til +3,00
Fasediagnosticering Viser fasen for alle, røde og blå bølgelængder. Opdaterer hvert sekund.
Diagnosticering af amplitude Viser amplituden for røde og blå bølgelængder. Opdateres hvert sekund.
Dage til rengøring Viser antal dage, før næste planlagte, manuelle rengøring skal udføres.
Sensorens levetid Viser antal dage, før næste planlagte udskiftning af sensorhætten skal udføres..
Fejlliste
Hvis der opstår en fejl, blinker teksten på målingsskærmbilledet. Output bestemmes af
kontrolenhedens indstillinger. Se brugervejledningen til kontrolenheden for at få flere oplysninger.
Hvis du vil se de aktuelle sensorfejl, skal du gå til MENU>SENSORDIAGNOSTICS>[Vælg
sensor]>FEJLLISTE. Se Tabel 6.
Tabel 6 Fejlliste for LDO-sensoren
Fejl Mulig årsag Løsning
Rød amplitude er for lav. (Værdien er under
0.01)
eller
Blå amplitude er for lav. (Værdien er under
0.01)
Sensorhætten er ikke
installeret eller er ikke
installeret korrekt.
Fjern sensorhætten, og
installer den igen.
Lysets vej er blokeret i
sensorhætten.
Undersøg indersiden af
sensorhætten og linsen.
Sensoren fungerer ikke
korrekt.
Kontroller, at LED-indikatoren
blinker. Kontakt producenten.
Advarselsliste
Når advarselsikonet blinker (sc100 og sc200), eller når skærmbilledet bliver gult (sc1000), vises en
meddelelse nederst i målingsskærmbilledet. På sc1000 bliver skærmbilledet gult for at vise en
advarsel. Hvis du vil se de aktuelle sensorfejl, skal du gå til MENU>SENSOR DIAGNOSTICS>[Vælg
sensor]>WARNING LIST (MENU>DIAGNOSTIK>[Vælg sensor]>ADVARSELSLISTE). Se Tabel 7.
Tabel 7 Sensors advarselsliste
Advarsel Definition Opløsning
EEPROM-opsætningsfejl Lageret er beskadiget. Værdierne er
angivet til standardindstillingerne.
Kontakt teknisk support.
EEPROM-fejl
Dansk 61
Tabel 7 Sensors advarselsliste (fortsat)
Advarsel Definition Opløsning
Temperatur < 0 °C Procestemperaturen er under 0 °C
(32 °F)
Øg procestemperaturen eller afbryd
anvendelsen, indtil procestemperaturen
ligger inden for det angivne interval for
sensoren.
Temperatur > 50 °C Procestemperaturen er over 50 °C
(120 °F)
Reducer procestemperaturen eller
afbryd anvendelsen, indtil
procestemperaturen ligger inden for det
angivne interval for sensoren.
Rød amplitude er for lav. Værdien falder under 0,03 Se Fejlliste på side 61 .
Rød amplitude er for høj. Værdien er over 0,35 Kontakt teknisk support.
Blå amplitude er for lav. Værdien er under 0,03 Se Fejlliste på side 61.
Blå amplitude er for høj. Værdien er over 0,35 Kontakt teknisk support.
Lot nummer på
sensorhætte mangler.
Sensorhætten er blevet beskadiget.
Koden nulstilles automatisk til
standardhætte- og partikoderne.
Udfør proceduren for sensorens
starthætte. Hvis der ingen starthætte til
sensoren findes, kontaktes den tekniske
supportafdeling.
Hændelsesliste
Hændelseslisten indeholder en log over tilpasning af, hvordan sensoren registrerer data. Hvis du vil
se sensorhændelserne, skal du gå til MENU>SENSORDIAGNOSTICS>[Vælg
sensor]>HÆNDELSESLISTE.
Se Tabel 8.
Tabel 8 Hændelsesliste til sensoren
Hændelse Beskrivelse
Ændring i højde/trykenhed Det atmosfæriske tryk eller højdeenhederne er ændrede.
Ændring i højde/tryk Værdien for højde eller atmosfærisk tryk har ændret sig.
Ændring i temperatur Temperaturenheden er ændret.
Ændring i enhed En måleenhed er ændret.
Ændring i salinitetindhold Værdien for salinitetindhold er ændret.
Reset (Nulstil) Sensorindstillingerne er blevet nulstillet til standardværdierne.
Ændring i sensoropsætning Sensoropsætningen er ændret.
Ændring i rengøringsinterval Perioden mellem sensorrengøringerne er ændret.
Ændring i sensorens levetid Perioden mellem udskiftningerne af sensorhætten er ændret.
62 Dansk
Użytkowanie
Konfiguracja czujnika
Aby wprowadzić informacje identyfikacyjne czujnika i zmienić opcje obsługi i przechowywania
danych, należy przejść do menu Ustawienia.
Informacje na temat montażu czujnika można znaleźć w podręczniku użytkownika.
Upewnij się, że wszystkie wartości w menu Ustawienia są prawidłowe dla danego zastosowania.
1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA.
2. Wybierz opcję, ENTER. Listę dostępnych opcji przedstawiono w poniższej tabeli.
Opcja Opis
Nazwa Zmienia nazwę czujnika, wyświetlaną na górze ekranu pomiarowego. Nazwa nie
może być dłuższa niż 10 znaków i może stanowić dowolną kombinację liter, cyfr,
odstępów i znaków interpunkcyjnych.
Jednostka Temperatura — umożliwia wybranie jednostek temperatury °C (wartość domyślna)
lub °F.
Pomiar — umożliwia wybranie jednostek miar w mg/L, ppm lub %.
Wysokość n.p.m./ciśnienie — umożliwia wybranie jednostek wysokości w m lub
ft bądź wybranie jednostek ciśnienia atmosferycznego w mmHg lub torach. (Wartość
domyślna = 0 ft)
Wysokość
n.p.m./ciśnienie
Wprowadź wartość wysokości nad poziom morza lub ciśnienia atmosferycznego.
Wartość ta musi być dokładna, aby zakończyć pomiar % nasycenia i kalibracji
w powietrzu. (Domyślnie = 0 ft).
Zasolenie Wprowadź wartość zasolenia. Zakres zasolenia: 0,00 do 250,00 części na tysiąc
(‰). (Wartość domyślna = 0)
Uśrednianie sygnału Ustawienie interwału czasowego dla średniej sygnału w sekundach
Interwał czyszczenia Ustawienie interwału czasowego dla ręcznego czyszczenia czujnika w dniach
(Wartość domyślna = 0 dni. Wartość 0 dni wyłącza międzyczasy czyszczenia.)
Resetuj interwał
czyszczenia
Ustawienie interwału czasowego na ostatni zapisany interwał czasowy czyszczenia
Interwał rejestracji danych Umożliwia określenie interwału czasowego przechowywania danych w rejestrze: 0,5,
1, 2, 5, 10, 15 (domyślnie), 30, 60 minut.
Resetuj Przywraca konfigurowalne wartości domyślne dla czujnika. Nie zmienia ustawienia
krzywej lub offsetu.
Wprowadzenie wartości ciśnienia atmosferycznego
Ustawienie fabryczne dla ciśnienia atmosferycznego (powietrza) wynosi 0 ft, według poziomu morza.
Aby zmienić wartość domyślną, wykonaj czynności opisane w tej procedurze. Regulację ciśnienia
powietrza przeprowadza się według wysokości nad poziom morza lub w jednostkach ciśnienia
(preferowane).
Uwaga: Dokładne ciśnienie powietrza ma krytyczne znaczenie dla kalibracji powietrza nasyconego. Używaj tylko
ciśnienia bezwzględnego, bez korekt. Jeśli ciśnienie absolutne powietrza nie jest znane, zastosuj wysokość według
lokalizacji.
Polski
63
1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz
czujnik]>USTAWIENIA>JEDNOSTKA>CIŚNIENIE POWIETRZA/WYSOKOŚĆ N.P.M.
2. Wybierz jedną z wymienionych jednostek pomiarowych:
Opcja Opis
Wysokość n.p.m. (stopy) Stopa (ft) — jednostka pomiarowa wysokości
Wysokość n.p.m. (m) Metry — jednostka metryczna pomiaru wysokości
Ciśnienie powietrza w mmHg Milimetry słupa rtęci — jednostka metryczna pomiaru ciśnienia absolutnego
powietrza
Ciśnienie powietrza w torach Jednostka pomiarowa ciśnienia absolutnego powietrza
3. Potwierdzić wybór. Na ekranie wprowadzania wartości pojawią się wybrane jednostki.
4. Wprowadź wartość, a następnie potwierdź.
Wprowadzanie wartości korekcji zasolenia
Pomiary rozpuszczonego tlenu w próbkach soli mogą pokazać pozorną wartość
DO (rozpuszczonego tlenu), która bardzo różni się od wartości rzeczywistej DO. Do skorygowania
wpływu rozpuszczonych soli w próbce wprowadza się współczynnik korygujący zasolenie.
Uwaga: Jeśli obecność lub ilość zasolenia w procesie nie jest znana, skonsultuj się z kadrą inżynierską zakładu
przetwarzania odpadów.
1. Użyj miernik przewodności do pomiaru przewodności próbki w mS/cm w temperaturze
odniesienia 20 °C (68 °F).
2. Zobacz Tabela 1, aby ocenić współczynnik korygujący zasolenie w liczbie części na tysiąc (‰)
nasycenia.
Uwaga: Stężenie jonów chloru, w g/kg jest równe stężeniu chlorków w próbce. Zasolenie jest obliczane
ze wzoru: zasolenie = 1,80655 × stężenie chlorków.
Zasolenie może być obliczane z według zależności w sekcji 2520 B dokumentu Standardowe
metody badania wody i ścieków.
1
,
3. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA>ZASOLENIE.
4. Wprowadź współczynnik korygujący zasolenie i potwierdź.
1
Standard Methods for the Examiniation of Water and Wastewater (Standardowe metody badania
wody i ścieków), wydanie 20. Wydawcy Lenore S. Clesceri, Arnold E. Greenberg i Andrew D.
Eaton, str. 2-48-2-29 (1998). Zależność pomiędzy rozpuszczalnością chlorków i tlenu jest w tym
samym dokumencie w 4500-O:I str. 4-131.
64 Polski
Tabela 1 Nasycenie zasolenia (‰) na wartość przewodności (mS/cm)
mS/cm mS/cm mS/cm mS/cm
5 3 16 10 27 18 38 27
6 4 17 11 28 19 39 28
7 4 18 12 29 20 40 29
8 5 19 13 30 21 42 30
9 6 20 13 31 22 44 32
10 6 21 14 32 22 46 33
11 7 22 15 33 23 48 35
12 8 23 15 34 24 50 37
13 8 24 17 35 25 52 38
14 9 25 17 36 25 54 40
15 10 26 18 37 26
Kalibracja pomiarów
Czujnik jest skalibrowany według specyfikacji fabrycznej. Producent nie zaleca kalibracji, chyba że jej
przeprowadzenie jest wymagane okresowo zgodnie z odnośnymi przepisami. Jeśli kalibracja jest
wymagana, należy przed kalibracją zrównoważyć czujnik w cieczy procesowej. Nie należy
kalibrować czujnika podczas jego konfigurowania.
Tabela 2 przedstawia opcje kalibracji.
Tabela 2 Opcje kalibracji
Opcja Opis
Kalibracja powietrza Zalecana metoda kalibracji. Kalibracja ta zmienia wartości krzywej.
Kalibracja Kalibracja według porównania z przenośnym miernikiem DO ( tlenu rozpuszczonego).
Kalibracja ta zmienia wartość offsetu.
Resetowanie kalibracji Przywraca wzmocnienie kalibracji (krzywej) i offset do domyślnych ustawień
fabrycznych: wzmocnienie domyślne=1.0; offset domyślny=0.0
Kalibracja powietrza
Uwagi przeznaczone dla użytkowników:
Upewnij się, że w worku kalibracyjnym jest woda.
Upewnij się, że uszczelka pomiędzy workiem kalibracyjnym i korpusem czujnika jest szczelna.
Upewnij się, że czujnik jest suchy podczas kalibracji.
Upewnij się, że ciśnienie powietrza/ustawienie wysokości jest prawidłowe w lokalizacji kalibracji.
Zapewnij wystarczająco dużo czasu na ustabilizowanie się temperatury czujnika do temperatury
w lokalizacji worka kalibracyjnego. W przypadku dużej różnicy temperatur pomiędzy cieczą
procesową i lokalizacją kalibracji jej ustabilizowanie może trwać do 15 minut.
1. Wyjmij czujnik z cieczy procesowej. Do czyszczenia czujnika użyj wilgotnej szmatki.
2. Umieść cały czujnik w worku kalibracyjnym z wodą o objętości 25-50 ml. Upewnij się,
że nakładka czujnika nie jest w kontakcie z wodą wewnątrz worka kalibracyjnego, a na jej
powierzchni nie ma żadnych kropel wody.
3. Zapewnij uszczelnienie wokół korpusu czujnika używając do tego taśmy gumowej, cięgna lub
ręki.
Polski
65
4. Odczekaj 15 minut aż przyrząd się ustabilizuje przed kalibracją. W czasie stabilizacji chroń worek
kalibracyjny przed bezpośrednim światłem słonecznym.
5. Upewnij się, że aktualne bezwzględne ciśnienie powietrza oraz wysokość n.p.m. są poprawnie
skonfigurowane.
Uwaga: Producent zaleca jako najlepszą praktykę stosowanie bezwzględnego lub rzeczywistego ciśnienia
powietrza.
6. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KALIBRACJA>KALIBRACJA
POWIETRZA.
7. Wybierz opcję sygnału wyjściowego używanego podczas kalibracji:
Opcja Opis
Aktywne Podczas procedury kalibracji instrument wysyła aktualną mierzoną wartość wyjściową.
Wstrzymaj Podczas procedury kalibracji wartość wyjściowego sygnału czujnika jest utożsamiana
z aktualnie mierzoną wartością.
Transfer Podczas procedury kalibracji jest wysyłana wartość zadana sygnału wyjściowego. Informacje
na temat zmiany wartości zadanej można znaleźć w podręczniku użytkownika urządzenia
sterującego.
8. Sterownik wyświetla komunikat „Włóż cały czujnik do worka z wodą”. Odczekaj, aż wartość się
ustabilizuje. Naciśnij klawisz ENTER, aby zaakceptować wartość ustabilizowaną. Opcjonalnie
pozwól na kontynuowanie kalibracji, dopóki na wyświetlaczu nie pojawi się komunikat „Pomyślnie
wykonano zadanie” .
9. Po ukończeniu kalibracji czujnika, umieść go w cieczy procesowej. Naciśnij klawisz ENTER.
Rysunek 1 Procedura kalibracji powietrza
Jeśli nie nastąpi ustabilizowanie się wartości, na wyświetlaczu pojawi się napis „Unable to Calibrate”
(Nie można dokonać kalibracji), a następnie komunikaty o błędach. Tabela 3 pokazuje komunikat
o błędzie i rozwiązanie problemu kalibracji.
Tabela 3 Komunikaty o błędach dotyczące kalibracji powietrza
Komunikat Opis Rozwiązanie
Kalibracja nieudana! Korekcja
wzmocnienia za wysoka.
Obliczona wartość wzmocnienia jest zbyt wysoka. Powtórz kalibrację.
Kalibracja nieudana! Korekcja
wzmocnienia za niska.
Obliczona wartość wzmocnienia jest zbyt niska. Powtórz kalibrację.
Kalibracja nieudana! Niestabilna Wartość nie uległa stabilizacji w przewidzianym
czasie kalibracji.
Powtórz kalibrację.
66 Polski
Kalibracja poprzez porównanie
Ta metoda kalibracji używa alternatywnego czujnika dołączonego do miernika podręcznego.
1. Wstaw alternatywny czujnik do cieczy procesowej. Wstaw drugi czujnik możliwie blisko czujnika
pierwszego.
2. Poczekaj, aż wartość DO (rozpuszczonego tlenu) się ustabilizuje.
3. Na sterowniku pierwszego czujnika przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz
czujnik]>KALIBRACJA>KALIBRACJA.
4. Wybierz opcję sygnału wyjściowego używanego podczas kalibracji:
Opcja Opis
Aktywne Podczas procedury kalibracji instrument wysyła aktualną mierzoną wartość wyjściową.
Wstrzymaj Podczas procedury kalibracji wartość wyjściowego sygnału czujnika jest utożsamiana
z aktualnie mierzoną wartością.
Transfer Podczas procedury kalibracji jest wysyłana wartość zadana sygnału wyjściowego. Informacje
na temat zmiany wartości zadanej można znaleźć w podręczniku użytkownika urządzenia
sterującego.
5. Urządzenie sterujące pokazuje:
„Czy odczyt jest stabilny?”
Aktualny pomiar rozpuszczonego tlenu (DO)
Aktualny pomiar temperatury
6. Po ustabilizowaniu się pomiaru naciśnij ENTER. Na wyświetlaczu pojawi się ekran wejścia.
Uwaga: Zwykle pomiar stabilizuje się w ciągu 2 do 3 minut.
Jeśli nie nastąpi ustabilizowanie się wartości, na wyświetlaczu pojawi się napis „Unable to Calibrate”
(Nie można dokonać kalibracji), a następnie komunikaty o błędach. Tabela 4 pokazuje komunikat
o błędzie i rozwiązanie problemu kalibracji.
Tabela 4 Komunikaty o błędach dotyczące kalibracji próbki
Komunikat Opis Rozwiązanie
Kalibracja nieudana! Przesunięcie
za duże.
Obliczona wartość offsetu jest zbyt wysoka. Powtórz kalibrację.
Kalibracja nieudana! Przesunięcie
za małe.
Obliczona wartość offsetu jest zbyt niska. Powtórz kalibrację.
Kalibracja nieudana! Niestabilna Wartość nie uległa stabilizacji w przewidzianym
czasie kalibracji.
Powtórz kalibrację.
Zamykanie procedury kalibracji
1. Podczas kalibracji naciśnij przycisk BACK. Zostaną wyświetlone trzy opcje:
Opcja Opis
Anuluj Kończy kalibrację. Należy rozpocząć procedurę kalibracji od nowa.
Powróć do procedury
kalibracji
Powraca do aktualnej kalibracji.
Wyjście Tymczasowo przerywa kalibrację. Dostęp do innych pozycji menu jest
dozwolony, podczas gdy kalibracja jest nadal kontynuowana w tle. Można
rozpocząć kalibrację drugiego czujnika (jeśli jest używany). Aby powrócić
do kalibracji, naciśnij klawisz MENU i wybierz kolejno Ustawienia czujnika,
[Wybór czujnika].
2. Wybierz jedną z opcji. Potwierdź.
Polski
67
Reset do ustawień fabrycznych kalibracji
Ustawienia kalibracji można zresetować do ustawień fabrycznych. Wartości wzmocnienia i offsetu
są ustawione na 1,0 i 0,0, odpowiednio.
1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KALIBRACJA>RESETUJ
KALIBRACJĘ.
2. Na ekranie pojawi się komunikat o konfiguracji. Potwierdź reset czujnika do krzywej kalibracji
ustawień fabrycznych.
Konserwacja
N I E B E Z P I E C Z E Ń S T W O
Wiele zagrożeń. Tylko wykwalifikowany personel powinien przeprowadzać prace opisane w tym
rozdziale niniejszego dokumentu.
N I E B E Z P I E C Z E Ń S T W O
Zagrożenie wybuchem. Nie należy podłączać ani odłączać żadnych elektrycznych komponentów
i obwodów od urządzeń przed wyłączeniem zasilania, chyba że obszar nie jest objęty zagrożeniem.
N I E B E Z P I E C Z E Ń S T W O
Zagrożenie wybuchem. Zastąpienie komponentów innymi może spowodować, że urządzenia nie
będzie można używać w niebezpiecznych lokalizacjach Klasy 1, Dział 2. Nie wolno wymieniać żadnych
komponentów, chyba że zasilanie zostało wyłączone, a w pobliżu brak czynników stanowiących
zagrożenie.
P O W I A D O M I E N I E
Wersja certyfikowana tego produktu dla miejsc stwarzających zagrożenie nie spełnia wymogów dyrektywy
94/9/WE (Dyrektywa ATEX).
Plan konserwacji
Plan konserwacji uwzględnia minimalne międzyczasy wykonywania okresowych czynności
konserwacyjnych. Czynności konserwacyjne należy wykonywać częściej, jeśli sposób użytkowania
urządzenia prowadzi do szybszego zanieczyszczania elektrod.
Uwaga: Nie demontować sondy w celu konserwacji lub czyszczenia.
Praca konserwacyjna do wykonania Zalecana minimalna częstotliwość
Czyszczenie czujnika 90 dni
Sprawdzenie, czy czujnik nie jest uszkodzony 90 dni
Kalibracja czujnika Zgodnie z zaleceniami według odnośnych przepisów
Czyszczenie czujnika
Zewnętrzną powierzchnię czujnika czyścić miękką szmatką.
Uwaga: Po wyjęciu nakrętki pomiarowej czujnika do czyszczenia, nie należy narażać wnętrza nakrętki pomiarowej
na bezpośrednie działanie promieni słonecznych przez dłuższy czas.
Ustawianie i zmiana interwału czasowego czyszczenia
Warunki stosowania mogą wymagać krótszych lub dłuższych odstępów czasu pomiędzy ręcznym
czyszczeniem czujnika. Interwał czasowy ustawiony fabrycznie wynosi 0 dni. Aby zmienić interwał,
wykonaj czynności wymienione w tej procedurze.
68
Polski
1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA>INTERWAŁ
CZYSZCZENIA.
2. Zmień pokazywaną wartość w razie potrzeby. Potwierdź zmianę.
Aby wyłączyć interwał czasowy czyszczenia, ustaw wartość na „0”.
Zmiana nakrętki pomiarowej czujnika
O S T R Z E Ż E N I E
Potencjalne zagrożenie wybuchem. Nnakrętka pomiarowa ustawiania czujnika nie jest przystosowane
do używania w miejscach niebezpiecznych.
Zamienne nakrętki pomiarowe czujników i nakrętki pomiarowe są dostarczane razem z instrukcją
instalacji. Aby zmienić nakrętkę, zobacz dołączone instrukcje. Po zamontowaniu nowej nakrętki
czujnika upewnij się, że numer partii na nakrętce jest taki sam, jak numer odczytywany przez
Modbus. Czujnik pobiera informacje kalibracyjne z nakrętki czujnika.
Aby uzyskać najlepszą wydajność i dokładność, wymieniaj nakładkę czujnika:
Co dwa latalub częściej w razie konieczności
Kiedy normalna kontrola wykazuje znaczną erozję nakrywki czujnika.
Rozwiązywanie problemów
Menu diagnostyki i testów
Menu diagnostyki i testów wyświetla bieżące i historyczne informacje dotyczące czujnika LDO.
Aby uzyskać dostęp do menu diagnostyki i testów, przejdź do MENU>USTAWIENIA
CZUJNIKA>[Wybierz czujnik]>KONSERWACJA.
Patrz Tabela 5.
Tabela 5 Menu konserwacji
Opcja Opis
Informacja o czujniku Wersja oprogramowania — wyświetla informacje o wersji zainstalowanego
oprogramowania
Program uruchomieniowy — wyświetla informacje o wersji zainstalowanego
programu uruchomieniowego
Wersja oprogramowania — wyświetla informacje o wersji zainstalowanego
sterownika programowego
Kod partii nakrętki czujnika Pokazuje kod partii produkcyjnej na nakrywce czujnika
Numer seryjny Numer seryjny czujnika
Korekcja wzmocnienia Ustawienie wartości wzmocnienia kalibracji.
Zakres: 0,50 do 2,00
Korekcja przesunięcia Ustawienie wartości offsetu kalibracji (mg/L lub ppm).
Zakres: –3,00 do +3,00
Diagnostyka fazy Pokazuje fazę dla całkowitej, czerwonej, niebieskiej długości fali. Aktualizuje raz
na sekundę.
Diagnostyka amplitudy Pokazuje amplitudę dla całkowitej, czerwonej, niebieskiej długości fali. Aktualizuje
raz na sekundę.
Polski 69
Tabela 5 Menu konserwacji (ciąg dalszy)
Opcja Opis
Dni do czyszczenia Pokazuje liczbę dni do następnego zaplanowanego czyszczenia ręcznego.
Trwałość czujnika Pokazuje liczbę dni do następnej zaplanowanej wymiany nakrętki pomiarowej
czujnika..
Lista błędów
Jeśli wystąpi błąd, odczyt miga na ekranie pomiarowym. Zachowanie sygnału wyjściowego zależy
od ustawień sterownika. Więcej informacji można znaleźć w podręczniku użytkownika sterownika.
Aby wyświetlić aktualne błędy czujnika, przejdź do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz
czujnik]>LISTA BŁĘDÓW. Patrz Tabela 6.
Tabela 6 Błędy czujnika LDO
Błąd Możliwa przyczyna Rozwiązanie
Amplituda światła czerwonego za niska.
(Wartość niższa niż 0,01)
lub
Amplituda światła niebieskiego za niska.
(Wartość niższa niż 0,01)
Nakrętka pomiarowa czujnika
nie jest zainstalowana lub jej
zainstalowanie nie jest
prawidłowe.
Wyjmij nakrętkę pomiarową
czujnika i zainstaluj
ją ponownie.
Promień świetlny jest blokowany
w nakrętce pomiarowej czujnika.
Sprawdź nakrętkę pomiarową
czujnika od środka i obiektyw.
Czujnik nie działa poprawnie. Upewnij się, że wskaźnik LED
miga. Skontaktuj się
z producentem.
Lista ostrzeżeń
Kiedy miga ikona ostrzegania (sc100 i sc200) lub gdy ekran zmienia kolor na żółty (sc1000),
komunikat pojawi się na dole ekranu pomiarowego. W przypadku sc1000 ekran zmienia kolor
na żółty i pojawia się komunikat. Aby wyświetlić aktualne ostrzeżenia czujnika, przejdź
do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz czujnik]>LISTA OSTRZEŻEŃ. Patrz Tabela 7.
Tabela 7 Lista ostrzeżeń czujnika
Ostrzeżenie Opis Rozwiązanie
Błąd ustawień EEPROM Pamięć masowa jest uszkodzona.
Wartości zostaną ustawione
na fabryczne.
Skontaktuj się z działem pomocy
technicznej.
Błąd EEPROM
Temperatura <0°C Temperatura cieczy procesowej jest
poniżej 0 °C (32 °F)
Zwiększyć temperaturę cieczy procesowej
lub przerwać procedurę aż temperatura
cieczy procesowej znajdzie się w zakresie
specyfikacji czujnika.
Temperatura >50°C Temperatura cieczy procesowej jest
powyżej 50 °C (120 °F)
Zmniejszyć temperaturę cieczy procesowej
lub przerwać procedurę aż temperatura
cieczy procesowej znajdzie się w zakresie
specyfikacji czujnika.
Amplituda światła
czerwonego za niska.
Wartość spadła poniżej 0,03 Zobacz Lista błędów na stronie 70 .
Amplituda światła
czerwonego za wysoka.
Wartość jest większa niż 0,35 Skontaktuj się z działem pomocy
technicznej.
Amplituda światła
niebieskiego za niska.
Wartość jest poniżej 0,03 Zobacz Lista błędów na stronie 70.
70 Polski
Tabela 7 Lista ostrzeżeń czujnika (ciąg dalszy)
Ostrzeżenie Opis Rozwiązanie
Amplituda światła
niebieskiego za wysoka.
Wartość jest większa niż 0,35 Skontaktuj się z działem pomocy
technicznej.
Brak kodu partii nakrętki
czujnika.
Kod nakrętki pomiarowej czujnika
został uszkodzony. Kod został
zresetowany automatycznie do kodu
fabrycznego nakrywki i partii.
Zakończ procedurę nakrętki pomiarowej
czujnika. Jeśli nakrętka ustawiania czujnika
nie jest dostępna dla nakrętki czujnika,
skontaktuj się z działem pomocy
technicznej.
Lista zdarzeń
W ramach listy zdarzeń prowadzony jest dziennik zmian sposobu zapisu danych przez czujnik. Aby
wyświetlić zdarzenia czujnika, przejdź do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz
czujnik]>LISTA ZDARZEŃ.
Patrz Tabela 8.
Tabela 8 Lista zdarzeń czujnika
Zdarzenie Opis
Altitude/Pressure unit change (Zmiana jednostek
wysokości n.p.m./ciśnienia)
Zostały zmienione jednostki ciśnienia atmosferycznego
lub wysokości.
Altitude/Pressure change (Zmiana wysokości
n.p.m./ciśnienia)
Została zmieniona wartość ciśnienia atmosferycznego
lub wysokości.
Temperature change (Zmiana temperatury) Zostały zmienione jednostki temperatury.
Unit change (Zmiana jednostki) Została zmieniona nowa jednostka pomiarowa.
Salinity change (Zmiana zasolenia) Została zmieniona wartość zasolenia.
Resetuj Ustawienia czujnika zostały zresetowane do wartości
domyślnych.
Sensor setup change (Zmiana ustawień czujnika) Zostało zmienione ustawienie czujnika.
Cleaning interval change (Zmiana interwału
czyszczenia)
Został zmieniony międzyczas czyszczenia czujnika.
Sensor life change (Zmiana trwałości czujnika) Został zmieniony międzyczas wymiany nakrywki
czujnika.
Polski 71
*DOC273.98.90592*
HACH COMPANY World Headquarters
P.O. Box 389, Loveland, CO 80539-0389 U.S.A.
Tel. (970) 669-3050
(800) 227-4224 (U.S.A. only)
Fax (970) 669-2932
www.hach.com
HACH LANGE GMBH
Willstätterstraße 11
D-40549 Düsseldorf, Germany
Tel. +49 (0) 2 11 52 88-320
Fax +49 (0) 2 11 52 88-210
www.de.hach.com
HACH LANGE Sàrl
6, route de Compois
1222 Vésenaz
SWITZERLAND
Tel. +41 22 594 6400
Fax +41 22 594 6499
©
Hach Company/Hach Lange GmbH, 2017.
All rights reserved. Printed in Germany.

Transcripción de documentos

DOC273.98.90592 LDO sensor 05/2017, Edition 1 Addendum—Operation with the SC1500 Controller Addendum—Betrieb mit dem SC1500 Controller Adenda—Funcionamiento con el controlador SC1500 Addendum—Fonctionnement avec le contrôleur SC1500 Addendum—Funzionamento con il controller SC1500 Addendum—Bediening met de SC1500 Controller Addendum—Operation med SC1500 Controller Addenda—Działanie z kontrolerem SC1500 English .............................................................................................................................. 3 Deutsch .......................................................................................................................... 11 Español .......................................................................................................................... 20 Français ......................................................................................................................... 29 Italiano ............................................................................................................................ 38 Nederlands ....................................................................................................................46 Dansk ..............................................................................................................................55 Polski .............................................................................................................................. 63 2 Operation Configure the sensor Use the Settings menu to enter identification information for the sensor and to change options for data handling and storage. For information about sensor installation, refer to the user manual. Make sure that all of the Settings menu values are correct for the application. 1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS. 2. Select an option, ENTER. The list of available options is shown in the table below. Option Description Name Changes the name that corresponds to the sensor on the top of the measure screen. The name is limited to 10 characters in any combination of letters, numbers, spaces or punctuation. Unit Temperature–Sets the temperature units to °C (default) or °F. Measurement–Set the measurement units in mg/L, ppm or % . Altitude/Pressure–Set the altitude in m or ft, or set the atmospheric pressure units in mmHg or torr. (Default value = 0 ft) Altitude/Pressure Enter the value of the altitude or atmospheric pressure. This value must be accurate to complete % saturation measurements and calibration in air. (Default = 0 ft). Salinity Enter the salinity value. Salinity range: 0.00 to 250.00 parts per thousand (‰). (Default value = 0) Signale average Set the time interval to average signal in seconds Cleaning interval Set the time interval for manual sensor cleaning in days (Default value = 0 days. A value of 0 days disables the clean interval.) Reset cleaning interval Set the time interval to the last saved clean interval Data logger interval Sets the time interval for data storage in the data log—0.5, 1, 2, 5, 10, 15 (default), 30, 60 minutes. Reset Restores the configurable default values for the sensor. Does not change the setting for slope or offset. Enter the atmospheric pressure value The factory setting for atmospheric (air) pressure is 0 ft, or sea level. To change the default value, use the steps in this procedure. The adjustment for air pressure is entered as either elevation or as pressure units (preferred). Note: Accurate air pressure is critical for saturated air calibration. Use only absolute pressure, not adjusted. If the absolute air pressure is not known, use the correct elevation for the location. 1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>UNIT>AIR PRESSURE/ALTITUDE. 2. Select one of the unit options listed: Option Description Altitude ft Feet—unit of measure for elevation Altitude m Meters—metric unit of measure for elevation Air pressure mmHg Millimeters of mercury—metric unit of measure for absolute air pressure Air pressure torr Unit of measure for absolute air pressure English 3 3. Confirm the selection. The value entry screen will show the selected units. 4. Enter the value, then confirm. Enter a salinity correction value Dissolved oxygen measurements in saline samples can show an apparent DO value that is very different from the actual DO value. To correct for the influence of dissolved salts in a sample, enter a salinity correction factor. Note: If the presence or amount of salinity in the process is unknown, consult with the treatment facility engineering staff. 1. Use a conductivity meter to measure the conductivity of the sample in mS/cm at a reference temperature of 20 °C (68 °F). 2. Use Table 1 to estimate the salinity correction factor in parts per thousand (‰) saturation. Note: The chloride ion concentration, in g/kg is equal to the chlorinity of the sample. Salinity is calculated with the formula: Salinity = 1.80655 × chlorinity. Salinity can be calculated with the relationship in section 2520 B of Standard Methods for the Examination of Water and Wastewater.1, 3. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>SALINITY. 4. Enter the salinity correction factor and confirm. Table 1 Salinity saturation (‰) per conductivity value (mS/cm) mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Calibration for measurements The sensor is calibrated to specification at the factory. The manufacturer does not recommend calibration unless periodically required by regulatory agencies. If calibration is required, let the sensor come to equilibrium with the process before calibration. Do not calibrate the sensor at setup. Table 2 shows options for calibration. 1 Standard Methods for the Examiniation of Water and Wastewater, 20th Edition. Editors Lenore S. Clesceri, Arnold E. Greenberg and Andrew D. Eaton, p. 2-48-2-29 (1998). The relationship between Chlorinity and Oxygen Solubitity is provided in the same reference in 4500-O:I p. 4-131. 4 English Table 2 Calibration options Option Description Air calibration Recommended calibration method. This calibration modifies the slope. Calibration Calibration by comparison with a hand-held DO meter . This calibration modifies the offset. Reset calibration Resets the calibration gain (slope) and offset to the factory default: default gain=1.0; default offset=0.0 Air calibration User notes: • • • • • Make sure that calibration bag has water inside. Make sure that the seal between the calibration bag and the sensor body is tight. Make sure that the sensor is dry when it is calibrated. Make sure the air pressure/elevation setting is accurate for the calibration location. Allow enough time for the sensor temperature to stabilize to the temperature of the calibration bag location. A large difference in temperature between the process and the calibration location can take up to 15 minutes to stabilize. 1. Remove the sensor from the process. Use a wet cloth to clean the sensor. 2. Put the entire sensor in a calibration bag with 25-50 mL of water. Make sure that the sensor cap is not in contact with the water inside the calibration bag and that no water drops are on the sensor cap. 3. Use a rubber band, tie or hand to create a tight seal around the sensor body. 4. Let the instrument stabilize for 15 minutes before calibration. Keep the calibration bag out of direct sunlight during stablization. 5. Make sure that the current absolute air pressure or elevation is configured correctly. Note: The manufacturer recommends the use of absolute or actual air pressure as a best practice. 6. Go to MENU>SENSOR SETUP>[Select Sensor]>CALIBRATION>AIR CALIBRATION. 7. Select the option for the output signal during calibration: Option Description Active The instrument sends the current measured output value during the calibration procedure. Hold The sensor output value is held at the current measured value during the calibration procedure. Transfer A preset value is sent during calibration. Refer to the controller user manual to change the preset value. 8. The controller will show "Put the entire sensor in the bag with water.". Allow the value to stabilize. Push ENTER to accept the stable value. Alternately, let the calibration continue until the display shows "Task was succesfully completed. ". 9. When the sensor is calibrated, put the sensor into the process. Push ENTER. English 5 Figure 1 Air calibration procedure If the value does not stabilize, the display will show "Unable to Calibrate" followed by an error message. Table 3 shows the error message and resolution for calibration problems. Table 3 Air calibration error messages Message Description Resolution Calibration failed! Gain correction is too high. The calculated gain value is too high. Repeat the calibration. Calibration failed! Gain correction is too low. The calculated gain value is too low. Repeat the calibration. Calibration failed! Unstable The value did not stabilize in the maximum allowed calibration time. Repeat the calibration. Calibration by comparison This calibration method uses an alternate sensor attached to a hand-held meter. 1. Put the alternate sensor into the process. Put the second sensor as close as possible to the first sensor. 2. Wait for the DO value to stabilize. 3. On the controller for the first sensor, go to MENU>SENSOR SETUP>[Select Sensor]>CALIBRATION>CALIBRATION. 4. Select the option for the output signal during calibration: Option Description Active The instrument sends the current measured output value during the calibration procedure. Hold The sensor output value is held at the current measured value during the calibration procedure. Transfer A preset value is sent during calibration. Refer to the controller user manual to change the preset value. 5. The controller will show: • "Is the reading stable?" • The current dissolved oxygen measurement • The current temperature measurement 6. When the measurement is stable, push ENTER. The display will show an entry screen. Note: The measurement will usually stabilize in 2 to 3 minutes. 6 English If the value does not stabilize, the display will show "Unable to Calibrate" followed by an error message. Table 4 shows the error message and resolution for calibration problems. Table 4 Sample cal error messages Message Description Resolution Calibration failed! Offset is too high. The calculated offset value is too high. Repeat the calibration. Calibration failed! Offset is too low. The calculated offset value is too low. Repeat the calibration. Calibration failed! Unstable The value did not stabilize in the maximum allowed Repeat the calibration. calibration time. Exit the calibration procedure 1. During calibration, push the BACK key. Three options are shown: Option Description Cancel Stop the calibration. A new calibration must start from the beginning. Return to calibration Return to the current calibration. Exit Exit the calibration temporarily. Access to other menus is allowed while the calibration continues in the background. A calibration for a second sensor (if present) can be started. To return to the calibration, push the MENU key and select Sensor Setup, [Select Sensor]. 2. Select one of the options. Confirm. Reset calibration defaults Calibration settings can be reset to the factory defaults. Gain and offset values are set to 1.0 and 0.0, respectively. 1. Go to MENU>SENSOR SETUP>[Select Sensor]>CALIBRATION>RESET CALIBRATION. 2. The display will show a confirmation message. Confirm to reset the sensor to the factory default calibration curve. Maintenance DANGER Multiple hazards. Only qualified personnel must conduct the tasks described in this section of the document. DANGER Explosion hazard. Do not connect or disconnect electrical components or circuits to the equipment unless power has been switched off or the area is known to be non-hazardous. DANGER Explosion hazard. Substitution of components may impair suitability for Class 1, Division 2. Do not replace any component unless power has been switched off and the area is known to be nonhazardous. NOTICE The hazardous location certified version of this product does not fulfill the requirements of the 94/9/EC Directive (ATEX Directive). English 7 Maintenance schedule The maintenance schedule shows minimum intervals for regular maintenance tasks. Perform maintenance tasks more frequently for applications that cause electrode fouling. Note: Do not disassemble the probe for maintenance or cleaning. Maintenance task Recommended minimum frequency Clean the sensor 90 days Inspect the sensor for damage 90 days Calibrate the sensor As recommended by regulatory agencies Clean the sensor Clean the exterior of the sensor with a soft, wet cloth. Note: If the sensor cap must be removed for cleaning, do not expose the interior of the cap to direct sunlight for extended periods of time. Set or change the clean interval Application conditions may need shorter or longer durations between manual sensor cleanings. The default clean interval is 0 days. To change the interval, refer to the steps in this procedure. 1. Go to MENU>SENSOR SETUP>[Select Sensor]>SETTINGS>CLEANING INTERVAL. 2. Change the shown value as needed. Confirm the change. • To turn off the clean interval, set the value to '0'. Change the sensor cap WARNING Potential explosion hazard. The sensor setup cap is not rated for hazardous location use. Replacement sensor caps and setup caps are shipped with installation instructions. Refer to the included instructions to change the cap. After the new sensor cap is installed, make sure that the lot number on the sensor cap is the same lot number that is read by Modbus. The sensor uses the calibration information from the sensor cap. For best performance and accuracy, replace the sensor cap: • Every two years, or more frequently if necessary • When routine inspection shows significant erosion of the sensor cap Troubleshooting Diagnostic and test menu The diagnostic and test menu shows current and historical information about the LDO sensor. To access the diagnostic and test menu, go to MENU>SENSOR SETUP>[Select Sensor]>MAINTENANCE. 8 English Refer to Table 5. Table 5 Maintenance menu Option Description Sensor information Software version—Shows the installed software version Boot pogram— Shows the installed boot version Driver version—Shows the installed software driver version Sensor cap lot code Shows the sensor cap manufacturing lot Serial number Sensor serial number Gain correction Adjust the calibration gain value. Range: 0.50 to 2.00 Offset correction Adjust the calibration offset value (mg/L or ppm). Range: –3.00 to +3.00 Phase diagnostics Shows the phase for total, red and blue wavelengths. Updates once per second. Amplitude diagnostics Shows the amplitude for red and blue wavelengths. Updates once per second. Days remaining to clean Shows the number of days until the next scheduled manual cleaning. Sensor life Shows the number of days until the next scheduled sensor cap replacement. Error list If an error occurs, the reading on the measurement screen flashes. Output behavior is determined by controller settings. Refer to the controller manual for details. To show the current sensor errors, go to MENU>SENSOR DIAGNOSTICS>[Select Sensor]>ERROR LIST. Refer to Table 6. Table 6 Error list for the LDO sensor Error Possible cause Resolution Red amplitude is too low. (Value is below 0.01) Remove the sensor cap and install it again. or The sensor cap is not installed, or is not installed correctly. Blue amplitude is too low. (Value is below 0.01) The light path is blocked in the sensor cap. Inspect the inside of the sensor cap and lens. The sensor is not operating correctly. Make sure that the LED is flashing. Contact the manufacturer. Warning list When the warning icon flashes (sc100 and sc200) or when the screen turns yellow (sc1000), a message is shown on the bottom of the measurement screen. On the sc1000, the screen turns yellow to show a warning. To show the current sensor warnings, go to MENU>SENSOR DIAGNOSTICS>[Select Sensor]>WARNING LIST. Refer to Table 7. Table 7 Sensor warning list Warning Definition Resolution EEPROM setup error Storage is corrupt. The values have been set to the factory default. Contact technical support. EEPROM error English 9 Table 7 Sensor warning list (continued) Warning Definition Resolution Temperature < 0 °C The process temperature is below 0 °C (32 °F) Increase the process temperature or stop use until the process temperature is in the sensor specification range. Temperature > 50 °C The process temperature is above 50 °C (120 °F) Decrease the process temperature or stop use until the process temperature is in the sensor specification range. Red amplitude is too low. Value falls below 0.03 Refer to Error list on page 9 . Red amplitude is too high. Value is greater than 0.35 Call technical support. Blue amplitude is too low. Value is below 0.03 Refer to Error list on page 9. Blue amplitude is too high. Value is greater than 0.35 Call technical support. Sensor cap lot code missing. The sensor cap code has become corrupt. The code has been reset automatically to the default cap and lot codes. Complete the sensor setup cap procedure. If no setup cap is available for the sensor cap, call technical support. Event list The Event list keeps a log of changes to how data is recorded by the sensor. To show sensor events, go to MENU>SENSOR DIAGNOSTICS>[Select Sensor]>EVENT LIST. Refer to Table 8. Table 8 Event list for the sensor Event Description Altitude/Pressure unit change Atmospheric pressure or altitude units have changed. Altitude/Pressure change The value for altitude or atmospheric pressure has changed. Temperature change The units for temperature have changed. Unit change A new unit of measurement has changed. Salinity change The value for salinity has changed. Reset Sensor settings have been reset to the default values. Sensor setup change The sensor setup has changed. Cleaning interval change The time between sensor cleaning has changed. Sensor life change The time between sensor cap replacements has changed. 10 English Betrieb Konfigurieren des Sensors Verwenden Sie das Menü „Einstellungen“, um eine Identifizierungsinformation für den Sensor einzugeben und die Optionen für die Datenverwaltung und -speicherung zu ändern. Informationen zur Sensor-Installation entnehmen Sie bitte dem Benutzerhandbuch. Stellen Sie sicher, dass alle Werte des Menüs „Einstellungen“ für die Anwendung korrekt sind. 1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>EINSTELLUNGEN auf. 2. Wählen Sie eine Option aus, und drücken Sie EINGABE. In der folgenden Tabelle wird eine Liste der verfügbaren Optionen angezeigt. Optionen Beschreibung Name Ändert den Namen des Messorts für den Sensor oben in der Messungsanzeige. Der Name darf maximal 10 Zeichen lang sein und Buchstaben, Zahlen, Leerzeichen und Satzzeichen enthalten. Einheit Temperatur: Legt die Temperatureinheit fest: °C (Standard) oder °F. Maßeinheit: Legt die Maßeinheiten (mg/l, ppm oder %) fest. Höhe/Druck: Legt die Höhe (m oder Fuß) fest oder aber die Einheiten des Atmosphärendrucks (mmHg oder Torr). (Standardwert = 0 m) Höhe/Druck Geben Sie den Wert für die Höhe oder den Atmosphärendruck ein. Dieser Wert muss genau sein, um die Messung der Sättigung in % und die Kalibrierung in Luft abschließen zu können. (Standardwert = 0 m) Salinität Geben Sie den Wert des Salzgehalts ein. Bereich des Salzgehalts: 0,00 bis 250,00 Promille (‰). (Standardwert = 0) Mittelwert Legen Sie das Zeitintervall für den Mittelwert des Signals in Sekunden fest. Reinigungsintervall Legen Sie das Zeitintervall für die manuelle Sensorreinigung in Tagen fest (Standardwert = 0 Tage. Mit einem Wert von 0 Tagen wird das Reinigungsintervall deaktiviert.) Reinigungsintervall zurücksetzen Setzt das Reinigungsintervall zurück. Datenlogger-Intervall Legt das Zeitintervall für die Datenspeicherung im Datenprotokoll fest: 0,5, 1, 2, 5, 10, 15 (Standardwert), 30 oder 60 Minuten. Zurücksetzen Stellt die konfigurierbaren Standardwerte des Sensors wieder her. Ändert nicht die Einstellung für Steilheit oder Offset. Eingeben des Atmosphärendrucks Die Werkseinstellung für den atmosphärischen (Luft-)Druck entspricht 0 m bzw. Normalnull. Befolgen Sie die Schritte in dieser Vorgehensweise, um den Standardwert zu ändern. Die Anpassung des Luftdrucks wird entweder als Höhe oder in Druckeinheiten (empfohlen) eingegeben. Hinweis: Für die Kalibrierung in gesättigter Luft ist der genaue Luftdruck entscheidend. Verwenden Sie nur den absoluten Luftdruck, nicht den angepassten. Falls der absolute Luftdruck nicht bekannt ist, verwenden Sie die dem Standort entsprechende Höhe. 1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>EINSTELLUNGEN>LUFTDRUCK/HÖHE auf. 2. Wählen Sie eine der aufgeführten Einheitenoptionen aus: Optionen Beschreibung Höhe ft Fuß: Maßeinheit für Höhe Deutsch 11 Optionen Beschreibung Höhe m Meter: metrische Maßeinheit für Höhe Luftdruck mmHg Millimeter Quecksilber: metrische Maßeinheit für absoluten Luftdruck Luftdruck Torr Maßeinheit für absoluten Luftdruck 3. Bestätigen Sie die Auswahl. Im Bildschirm für die Werteeingabe werden die ausgewählten Einheiten angezeigt. 4. Geben Sie den Wert ein und bestätigen Sie diesen anschließend. Eingeben eines Salzgehalt-Korrekturwerts Bei Messungen von gelöstem Sauerstoff in salzigen Proben kann ein Sauerstoff-Wert angezeigt werden, der sich stark von dem tatsächlichen Sauerstoff-Wert unterscheidet. Zur Korrektur des Einflusses von gelösten Salzen in einer Probe geben Sie einen Salzgehalt-Korrekturwert ein. Hinweis: Falls das Vorhandensein von Salz oder der Grad des Salzgehalts in dem Prozess unbekannt ist, konsultieren Sie das technische Personal der Behandlungsanlage. 1. Mit einer Leitfähigkeitsmessung bestimmen Sie die Leitfähigkeit der Probe in mS/cm bei einer Referenztemperatur von 20 °C. 2. Anhand von Tabelle 1 schätzen Sie den Korrekturfaktor für den Salzgehalt in Promille (‰) der Sättigung. Hinweis: Die Chloridionenkonzentration in g/kg entspricht dem Chloridgehalt in der Probe. Der Salzgehalt wird mit folgender Formel berechnet: Salzgehalt = 1,80655 x Chloridgehalt. Der Salzgehalt kann anhand des Verhältnisses in Abschnitt 2520 B der Standardmethoden für die Untersuchung von Wasser und Abwasser berechnet werden.1, 3. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>EINSTELLUNGEN>SALZGEHALT auf. 4. Geben Sie den Salzgehalt-Korrekturwert ein und bestätigen Sie diesen. Tabelle 1 Salzgehaltsättigung (‰) pro Leitfähigkeitswert (mS/cm) 1 mS/cm ‰ mS/cm ‰ 5 3 16 10 6 4 17 11 7 4 18 12 8 5 19 9 6 20 10 6 11 12 mS/cm ‰ mS/cm ‰ 27 18 38 27 28 19 39 28 29 20 40 29 13 30 21 42 30 13 31 22 44 32 21 14 32 22 46 33 7 22 15 33 23 48 35 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Standardmethoden für die Untersuchung von Wasser und Abwasser, 20. Ausgabe. Herausgeber Lenore S. Clesceri, Arnold E. Greenberg und Andrew D. Eaton, S. 2-48-2-29 (1998). Das Verhältnis zwischen Chloridgehalt und Sauerstofflöslichkeit ist in derselben Referenz in 4500-O:I S. 4-131 angegeben. 12 Deutsch Kalibrierung für Messungen Der Sensor wird im Werk gemäß den Spezifikationen kalibriert. Der Hersteller empfiehlt keine Kalibrierung, es sei denn, dies wird regelmäßig von Kontrollorganen gefordert. Falls eine Kalibrierung erforderlich ist, lassen Sie den Sensor mit dem Prozess ins Gleichgewicht kommen, bevor Sie eine Kalibrierung durchführen. Kalibrieren Sie den Sensor nicht beim Setup. In Tabelle 2 werden Optionen für die Kalibrierung angezeigt. Tabelle 2 Kalibrieroptionen Optionen Beschreibung Luftkalibrierung Empfohlene Kalibrierungsmethode. Durch diese Kalibrierung wird die Steilheit verändert. Kalibrierung Kalibrierung durch Vergleich mit einem tragbaren Sauerstoff-Messgerät. Durch diese Kalibrierung wird der Offset verändert. Kalibrierung zurücksetzen Setzt den Stellfaktor der Kalibrierung (Steilheit) und den Offset auf den Werksstandard: standardmäßiger Stellfaktor = 1,0; standardmäßiger Offset = 0,0. Luftkalibrierung Benutzerhinweise: • Vergewissern Sie sich, dass sich Wasser im Kalibrierungsbeutel befindet. • Vergewissern Sie sich, dass die Dichtung zwischen dem Kalibrierungsbeutel und dem Sensorgehäuse dicht ist. • Vergewissern Sie sich, dass der Sensor beim Kalibrieren trocken ist. • Vergewissern Sie sich, dass die Luftdruck-/Höheneinstellung für den Kalibrierungsstandort akkurat ist. • Lassen Sie dem Sensor genügend Zeit, die Temperatur des Standortes des Kalibrierungsbeutels anzunehmen. Bei einem großen Temperaturunterschied zwischen dem Prozess und dem Kalibrierungsstandort kann die Temperaturstabilisierung bis zu 15 Minuten in Anspruch nehmen. 1. Entnehmen Sie den Sensor aus dem Prozess. Reinigen Sie den Sensor mit einem feuchten Tuch. 2. Geben Sie den gesamten Sensor in einen Kalibrierungsbeutel mit 25 bis 50 ml Wasser. Vergewissern Sie sich, dass die Sensorkappe keinen Kontakt zu dem Wasser im Kalibrierungsbeutel hat und dass sich keine Wassertropfen auf der Sensorkappe befinden. 3. Dichten Sie mit Hilfe eines Gummibands, eines Bindfadens oder der Hand den Kalibrierbeutel zum Sensor hin ab. 4. Lassen Sie dem Messgerät vor der Kalibrierung 15 Minuten Zeit, sich zu stabilisieren. Setzen Sie den Kalibrierungsbeutel während der Kalibrierung nicht direktem Sonnenlicht aus. 5. Vergewissern Sie sich, dass der aktuelle absolute Luftdruck bzw. die Höhenangabe ordnungsgemäß konfiguriert ist. Hinweis: Der Hersteller empfiehlt die Verwendung des absoluten bzw. tatsächlichen Luftdrucks als empfohlene Vorgehensweise. 6. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>KALIBRIERUNG>LUFTKALIBRIERUNG auf. 7. Wählen Sie eine Option für das Ausgangssignal während der Kalibrierung: Optionen Beschreibung Aktiv Das Gerät übermittelt während der Kalibrierung den aktuellen Messwert. Halten Das Gerät hält den aktuellen Messwert während der Kalibrierung. Ersatzwert Das Gerät übermittelt während der Kalibrierung einen vorher eingestellten Wert. Informationen zur Einstellung des Ersatzwertes entnehmen Sie bitte der Bedienungsanleitung des Controllers. Deutsch 13 8. Auf dem Controller wird Folgendes angezeigt: „Geben Sie den gesamten Sensor in den Beutel mit Wasser.“ Lassen Sie dem Wert Zeit, sich zu stabilisieren. Drücken Sie ENTER, um den stabilen Wert zu akzeptieren. Alternativ kann die Kalibrierung fortgesetzt werden, bis Folgendes angezeigt wird: „Aufgabe wurde erfolgreich beendet. “ 9. Wenn der Sensor kalibriert ist, fügen Sie den Sensor in den Prozess ein. Drücken Sie ENTER. Abbildung 1 Luftkalibrierung Wenn sich der Wert nicht stabilisiert, wird in der Anzeige "Kann nicht kalibrieren" gefolgt von einer Fehlermeldung angezeigt. In Tabelle 3 werden die Fehlermeldung und die Auflösung für Kalibrierungsprobleme angezeigt. Tabelle 3 Fehlermeldungen beim Kalibrieren mit Luft Meldung Beschreibung Auflösung Kalibrierung fehlgeschlagen! Korrekturfaktor ist zu hoch. Der berechnete Verstärkungswert ist zu hoch. Kalibrierung wiederholen. Kalibrierung fehlgeschlagen! Korrekturfaktor ist zu niedrig. Der berechnete Verstärkungswert ist zu niedrig. Kalibrierung wiederholen. Kalibrierung fehlgeschlagen! Instabil Der Wert hat sich in der maximal zulässigen Kalibrierungszeit nicht stabilisiert. Kalibrierung wiederholen. Kalibrierung durch Vergleich Bei dieser Kalibrierung wird ein alternativer Sensor verwendet, der an ein tragbares Messgerät angeschlossen ist. 1. Fügen Sie den alternativen Sensor in den Prozess ein. Fügen Sie den zweiten Sensor so nahe wie möglich neben dem ersten Sensor ein. 2. Warten Sie, bis der Sauerstoff-Wert stabil ist. 3. Rufen Sie auf dem Controller für den ersten Sensor MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>KALIBRIERUNG>KALIBRIERUNG auf. 4. Wählen Sie eine Option für das Ausgangssignal während der Kalibrierung: Optionen Beschreibung Aktiv Das Gerät übermittelt während der Kalibrierung den aktuellen Messwert. Halten Das Gerät hält den aktuellen Messwert während der Kalibrierung. Ersatzwert Das Gerät übermittelt während der Kalibrierung einen vorher eingestellten Wert. Informationen zur Einstellung des Ersatzwertes entnehmen Sie bitte der Bedienungsanleitung des Controllers. 14 Deutsch 5. Auf dem Controller wird Folgendes angezeigt: • „Ist der Messwert stabil?“ • Die aktuelle Messung des gelösten Sauerstoffs • Die aktuelle Temperaturmessung 6. Wenn der Messwert stabil ist, drücken Sie ENTER. Auf dem Display wird ein Eingabebildschirm angezeigt. Hinweis: Die Messung stabilisiert sich in der Regel in 2 bis 3 Minuten. Wenn sich der Wert nicht stabilisiert, wird in der Anzeige "Kann nicht kalibrieren" gefolgt von einer Fehlermeldung angezeigt. In Tabelle 4 werden die Fehlermeldung und die Auflösung für Kalibrierungsprobleme angezeigt. Tabelle 4 Fehlermeldungen bei der IN-LINE Kalibrierung Meldung Beschreibung Auflösung Kalibrierung fehlgeschlagen! Offset ist zu hoch. Der berechnete Offsetwert ist zu hoch. Kalibrierung wiederholen. Kalibrierung fehlgeschlagen! Offset ist zu tief. Der berechnete Offsetwert ist zu niedrig. Kalibrierung wiederholen. Kalibrierung fehlgeschlagen! Instabil Der Wert hat sich in der maximal zulässigen Kalibrierungszeit nicht stabilisiert. Kalibrierung wiederholen. Verlassen der Kalibrierungsprozedur 1. Drücken Sie während der Kalibrierung die Taste ZURÜCK. Es werden drei Optionen angezeigt: Optionen Beschreibung Abbrechen Stoppt die Kalibrierung. Eine neue Kalibrierung muss von Anfang an ausgeführt werden. Zurück zur Kalibrierung Kehrt zur aktuellen Kalibrierung zurück. Beenden Verlässt die Kalibrierung vorübergehend. Zugriff auf andere Menüs ist zulässig, während die Kalibrierung im Hintergrund fortgesetzt wird. Sofern vorhanden, kann die Kalibrierung eines zweiten Sensors gestartet werden. Um zur Kalibrierung zurückzukehren, drücken Sie MENÜ und wählen Sie „Sensor-Setup“, [Sensor wählen]. 2. Wählen Sie eine der Optionen aus. Bestätigen Sie die Auswahl. Zurücksetzen der Kalibrierung auf die Standardwerte Kalibrierungseinstellungen können auf die werkseitigen Standardwerte zurückgesetzt werden. Die Werte für Stellfaktor und Offset werden auf 1,0 bzw. 0,0 gesetzt. 1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>KALIBRIERUNG>KALIBRIERUNG ZURÜCKSETZEN auf. 2. Im Display wird eine Bestätigungsmeldung angezeigt. Bestätigen Sie, dass Sie den Sensor auf die werkseitige Standardkalibrierungskurve zurücksetzen möchten. Wartung GEFAHR Mehrere Gefahren. Nur qualifiziertes Personal sollte die in diesem Kapitel des Dokuments beschriebenen Aufgaben durchführen. Deutsch 15 GEFAHR Explosionsgefahr. Elektrische Komponenten oder Schaltungen nur bei ausgeschalteter Stromversorgung oder in ungefährlichen Bereichen anschließen oder abtrennen. GEFAHR Explosionsgefahr. Das Austauschen von Komponenten kann die Eignung für Klasse I, Unterteilung 2, beeinträchtigen. Komponenten nur bei ausgeschalteter Stromversorgung und in ungefährlichen Bereichen austauschen. HINWEIS Die für gefährliche Standorte zertifizierte Version dieses Produkts erfüllt nicht die Anforderungen der Richtlinie 94/9/EG (ATEX-Richtlinie). Wartungsplan Im Wartungsplan sind die Mindestintervalle für die regelmäßige Wartung angegeben. Führen Sie die Wartungsaufgaben häufiger aus, wenn die Anwendungsbedingungen zum Zusetzen oder zu Verunreinigungen der Elektrode führen. Hinweis: Nehmen Sie das Gerät zur Wartung oder Reinigung nicht auseinander. Wartungsaufgabe Empfohlene Häufigkeit Reinigen des Sensors 90 Tage Sensor auf Schäden prüfen 90 Tage Kalibrieren des Sensors Wie von Kontrollorganen empfohlen Reinigen des Sensors Reinigen Sie das Äußere des Sensors mit einem weichen, feuchten Tuch. Hinweis: Wenn die Sensorkappe zum Reinigen entfernt werden muss, setzen Sie das Innere der Kappe nicht über einen längeren Zeitraum direktem Sonnenlicht aus. Festlegen oder Ändern des Reinigungsintervalls Anwendungsbedingungen erfordern u. U. kürzere oder längere Zeitabstände zwischen manuellen Sensorreinigungen. Das Standardreinigungsintervall beträgt 0 Tage. Befolgen Sie die Schritte in dieser Vorgehensweise, um das Intervall zu ändern. 1. Rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>EINSTELLUNGEN>REINIGUNGSINTERVALL auf. 2. Ändern Sie den angezeigten Wert nach Bedarf. Bestätigen Sie die Änderung. • Um das Reinigungsintervall abzuschalten, setzen Sie den Wert auf "0". Wechseln der Sensorkappe WARNUNG Mögliche Explosionsgefahr. Die Sensor-Kalibrierkappe ist nicht für die Verwendung an gefährlichen Standorten ausgelegt. Ersatz-Sensorkappen und Kalibrierkappen werden mit den Installationsanweisungen mitgeliefert. Befolgen Sie die entsprechenden Anweisungen, um die Kappe zu wechseln. Stellen Sie nach dem Anbringen der Sensorkappe sicher, dass die Chargennummer auf der Sensorkappe dieselbe ist, wie die, die von Modbus gelesen wird. Der Sensor nutzt die Kalibrierinformationen von der Sensorkappe. 16 Deutsch Um beste Leistung und Genauigkeit zu erzielen, ersetzen Sie die Sensorkappe: • alle zwei Jahre, oder häufiger, falls erforderlich, • wenn bei routinemäßiger Inspektion erhebliche Erosion festgestellt wird Fehlersuche und Behebung Diagnose- und Testmenü Im Diagnose- und Testmenü werden aktuelle und Langzeit-Informationen über den LDO-Sensor angezeigt. Um das Diagnose- und Testmenü aufzurufen, rufen Sie MENÜ>SENSOREINSTELLUNGEN>[Sensor auswählen]>WARTUNG auf. Siehe Tabelle 5. Tabelle 5 Wartungsmenü Optionen Beschreibung Sensorinformationen Softwareversion: Zeigt die installierte Softwareversion an Boot-Programm: Zeigt die installierte Boot-Version an Treiberversion: Zeigt die installierte Treiberversion an Sensorkappe-Chargencode Zeigt die Chargennummer der Sensorkappe an Seriennummer Seriennummer des Sensors Korrekturfaktor Passt den Stellfaktor der Kalibrierung an. Bereich. 0,50 bis 2,00 Offset-Korrektur Passt den Offsetwert der Kalibrierung an (mg/l oder ppm). Bereich: – 3,00 bis + 3,00 Phase Zeigt die Phase für alle, die roten und die blauen Wellenlängen an. Wird einmal pro Sekunde aktualisiert. Amplitude Zeigt die Amplitude für alle, die roten und die blauen Wellenlängen an. Wird einmal pro Sekunde aktualisiert. Verbleibende Tage bis zur Reinigung Zeigt den Zeitraum bis zur nächsten geplanten manuellen Reinigung in Tagen an. Lebensdauer des Sensors Zeigt den Zeitraum bis zum nächsten geplanten Austausch der Sensorkappe in Tagen an.. Fehlerliste Wenn ein Fehler auftritt, blinkt die Messung auf dem Messbildschirm. Das Ausgabeverhalten wird von den Controllereinstellungen bestimmt. Details dazu finden Sie im Benutzerhandbuch des Controllers. Deutsch 17 Um die aktuellen Sensorfehler anzuzeigen, rufen Sie MENÜ>SENSORSTATUS>[Sensor auswählen]>FEHLERLISTE auf. Siehe Tabelle 6. Tabelle 6 Fehlerliste für den Sauerstoff-Sensor Fehler Mögliche Ursache Auflösung Rote Amplitude ist zu niedrig. (Wert liegt unter 0,01) Die Sensorkappe ist nicht oder nicht richtig angebracht. Nehmen Sie die Sensorkappe ab, und bringen Sie sie erneut an. oder Der Strahlengang in der Sensorkappe ist blockiert. Inspizieren Sie die Innenseite der Sensorkappe und die Linse. Der Sensor funktioniert nicht ordnungsgemäß. Vergewissern Sie sich, dass die LED blinkt. Wenden Sie sich an den Hersteller. Blaue Amplitude ist zu niedrig. (Wert liegt unter 0,01) Warnungen Wenn das Symbol „Warnungen“ blinkt (sc100 und sc200) oder wenn der Bildschirm sich gelb färbt (sc1000), wird unten im Messbildschirm eine Mitteilung angezeigt. Beim sc1000 wird der Bildschirm gelb, um eine Warnung anzuzeigen. Um die aktuellen Sensorwarnungen anzuzeigen, rufen Sie MENÜ>SENSORSTATUS>[Sensor auswählen]>WARNUNGSLISTE auf. Siehe Tabelle 7. Tabelle 7 Warnungsliste Sensor Warnung Definition Auflösung EEPROM-Fehler EEPROM-Fehler Speicher ist beschädigt. Die Werte wurden auf den werkseitigen Standardwert gesetzt. Wenden Sie sich an den technischen Kundenservice. Temperatur < 0 C Die Prozesstemperatur liegt unter 0 °C Erhöhen Sie die Prozesstemperatur oder warten Sie, bis die Prozesstemperatur sich im sensorspezifischen Bereich befindet. Temperatur > 50 C Die Prozesstemperatur liegt über 50 °C Senken Sie die Prozesstemperatur oder warten Sie, bis die Prozesstemperatur sich im sensorspezifischen Bereich befindet. Rote Amplitude ist zu niedrig. Wert fällt unter 0,03 Siehe Fehlerliste auf Seite 17. Rote Amplitude ist zu hoch. Wert ist größer als 0,35 Wenden Sie sich an den technischen Kundenservice. Blaue Amplitude ist zu niedrig. Wert liegt unter 0,03 Siehe Fehlerliste auf Seite 17. Blaue Amplitude ist zu hoch. Wert ist größer als 0,35 Wenden Sie sich an den technischen Kundenservice. SensorkappeChargencode fehlt. Der Code der Sensorkappe wurde beschädigt. Der Code wurde automatisch auf die standardmäßigen Codes für die Kappe und Charge zurückgesetzt. Vervollständigen Sie die Vorgehensweise zum Einrichten der Sensorkappe. Wenn für die Sensorkappe keine Setup-Kappe vorhanden ist, wenden Sie sich an den technischen Kundendienst. Ereignisliste In der Ereignisliste werden Änderungen bei der Aufzeichnung von Daten durch den Sensor protokolliert. Um Sensorereignisse anzuzeigen, rufen Sie MENÜ>SENSORSTATUS>[Sensor auswählen]>EREIGNISLISTE auf. 18 Deutsch Siehe Tabelle 8. Tabelle 8 Liste möglicher Sensorereignisse Ereignis Beschreibung Änderung der Maßeinheit für Höhe/Druck Maßeinheiten für Atmosphärendruck oder Höhe wurden geändert. Änderung der Höhe/des Drucks Der Wert für die Höhe oder den Atmosphärendruck wurde geändert. Änderung der Temperatur Maßeinheiten für Temperatur wurden geändert. Änderung der Maßeinheit Eine Maßeinheit wurde geändert. Änderung des Salzgehalts Der Wert für den Salzgehalt wurde geändert. Zurücksetzen Sensoreinstellungen wurden auf Standardwerte zurückgesetzt. Änderung der Sensoreinstellungen Das Sensor-Setup wurde geändert. Änderung des Reinigungsintervalls Der Zeitraum zwischen den Sensorreinigungen wurde geändert. Änderung der Lebensdauer des Sensors Der Zeitraum für den Austausch der Sensorkappen wurde geändert. Deutsch 19 Funcionamiento Configuración del sensor Utilice el menú Configuración para introducir la información de identificación del sensor y para cambiar las opciones para el manejo y almacenamiento de datos. Si desea información sobre la instalación del sensor, consulte el manual del usuario. Asegúrese de que los valores del menú Configuración son correctos para la aplicación. 1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CONFIGURACIÓN. 2. Seleccione una opción y, a continuación, pulse ENTER (Intro). A continuación, se enumeran las opciones disponibles en una tabla. Opción Descripción Nombre Cambia el nombre que corresponde al sensor en la parte superior de la pantalla de medición. El nombre puede contener hasta 10 caracteres en cualquier combinación de letras, números, espacios o signos de puntuación. Unidad Temperatura: configura las unidades de temperatura en ºC (configuración predeterminada) o ºF. Medición: configura las unidades de medición en mg/l, ppm o %. Altitud/Presión: configura la altitud en m o pies, o configura las unidades de presión atmosférica en mmHg o torr. (Valor predeterminado = 0 pies) Altitud/Presión Introduzca el valor de la altitud o presión atmosférica. Este valor debe ser preciso para completar la calibración y las mediciones de la saturación en % del aire. (Predeterminado = 0 pies). Salinidad Introduzca el valor de salinidad. Intervalo de salinidad: de 0,00 a 250,000 partes por mil (‰). (Valor predeterminado = 0). Promedio de señal Configure el intervalo de tiempo al promedio de señal en segundos. Cleaning interval (Intervalo de limpieza) Establezca el intervalo de tiempo para la limpieza manual del sensor en días. (Valor predeterminado = 0 días. Un valor de 0 días desactiva el intervalo de limpieza). Reset cleaning interval (Restablecer intervalo de limpieza) Establezca el intervalo de tiempo al último intervalo de limpieza guardado. Data logger interval (Intervalo de registro de datos) Establece el intervalo de tiempo del almacenamiento de datos en el registro de datos: 0,5, 1, 2, 5, 10, 15 (predeterminado), 30 y 60 minutos. Restablecimiento Restablece los valores predeterminados configurables para el sensor. No modifique los ajustes para la pendiente o el desvío. Introducción de la unidad de presión atmosférica La configuración de fábrica de la presión atmosférica (aire) es de 0 pies o del nivel del mar. Para cambiar el valor predeterminado, siga los pasos de este procedimiento. El ajuste de la presión del aire se introduce como unidades de elevación o de presión (preferido). Nota: Para la calibración de aire saturado es fundamental una exacta presión del aire. Utilice únicamente presión absoluta, no ajustada. Si se desconoce la presión absoluta del aire, utilice la elevación correcta para la ubicación. 20 Español 1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CONFIGURACIÓN>UNIDAD>PRESIÓN DEL AIRE/ALTITUD. 2. Seleccione una de las opciones de unidades que se enumeran: Opción Descripción Altitud en pies Pie: unidad de medida para la elevación Altitud: m Metros: unidad métrica de medición de la elevación Air pressure mmHg (Presión del aire en mmHg) Milímetros de mercurio: unidad métrica de medición de la presión absoluta del aire Air pressure torr (Presión del aire en torr) Unidad de medición de la presión absoluta del aire 3. Confirme la selección. La pantalla de introducción del valor le mostrará las unidades seleccionadas. 4. Introduzca el valor y, a continuación, confírmelo. Introducción de un valor de corrección de salinidad Las mediciones de oxígeno disuelto en muestras de salino pueden mostrar un valor aparente del oxígeno disuelto muy diferente del valor actual de oxígeno disuelto. Para corregir la influencia de sales disueltas en una muestra, introduzca un factor de corrección de salinidad. Nota: Si se desconoce la presencia o la cantidad de salinidad del proceso, póngase en contacto con el personal de ingeniería del centro de tratamiento. 1. Utilice un medidor de conductividad para medir la conductividad de la muestra en mS/cm a una temperatura de referencia de 20 °C (68 °F). 2. Utilice la Tabla 1 para calcular el factor de corrección de salinidad en una saturación en partes por mil (‰). Nota: La concentración de iones cloruro, en g/kg, equivale a la clorinidad de la muestra. La salinidad se calcula con la fórmula: Salinidad = 1,80655 × clorinidad. La salinidad puede calcularse con la relación de la sección 2520 B de Standard Methods for the Examination of Water and Wastewater (Métodos estándar para la evaluación de las aguas y las aguas residuales).1, 3. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CONFIGURACIÓN>SALINIDAD. 4. Introduzca el factor de corrección de salinidad y confírmelo. 1 Standard Methods for the Examiniation of Water and Wastewater, Edición 20.º. Editores: Lenore S. Clesceri, Arnold E. Greenberg y Andrew D. Eaton, pág. 2-48-2-29 (1998). La relación entre la clorinidad y la solubilidad del oxígeno se proporciona en la misma obra de referencia, en 4500O:I, pág. 4-131. Español 21 Tabla 1 Saturación de la salinidad (‰) por valor de conductividad (mS/cm) mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Calibración de las mediciones El sensor se calibra en fábrica de acuerdo con las especificaciones. El fabricante no recomienda que se calibre a menos que las agencias de regulación soliciten calibraciones periódicas. En caso que se requiera una calibración, deje que el sensor se equilibre con el proceso antes de calibrarlo. No calibre el sensor durante la configuración. En la Tabla 2 se muestran las opciones de calibración. Tabla 2 Opciones de calibración Opción Descripción Calibración en aire Método de calibración recomendado. Esta calibración modifica la pendiente. Calibración Calibración por comparación con un medidor manual de oxígeno disuelto. Esta calibración modifica el desvío. Restablecer calibración Restablece la ganancia (pendiente) y el desvío de la calibración a los valores predeterminados de fábrica: ganancia predeterminada = 1,0; desvío predeterminado = 0,0 Calibración en aire Notas para el usuario: • • • • Asegúrese de que la bolsa de calibración contiene agua en el interior. Asegúrese de que el sellado entre la bolsa de calibración y el cuerpo del sensor es hermético. Asegúrese de que el sensor está seco cuando lo vaya a calibrar. Asegúrese de que los ajustes de la elevación y la presión del aire son adecuados para el lugar de calibración. • Deje tiempo suficiente para que la temperatura del sensor se estabilice con la temperatura del lugar de la bolsa de calibración. Si existe una gran diferencia entre la temperatura del proceso y la temperatura del lugar de calibración, es posible que el sensor tarde en estabilizarse hasta 15 minutos. 1. Retire el sensor del proceso. Utilice un paño húmedo para limpiar el sensor. 2. Ponga el sensor en su conjunto en una bolsa de calibración con unos 25 o 50 ml de agua. Asegúrese de que la cápsula del sensor no entra en contacto con el agua del interior de la bolsa de calibración y que no caen gotas de agua en la cápsula del sensor. 22 Español 3. Utilice una correa o lazo de goma o la mano para crear un sellado hermético alrededor del cuerpo del sensor. 4. Deje que el instrumento se estabilice durante 15 minutos antes de calibrarlo. Evite que la bolsa de calibración entre en contacto directo con la luz solar durante la calibración. 5. Asegúrese de que la elevación o la presión absoluta del aire actual estén configuradas correctamente. Nota: El fabricante recomienda el uso de una presión real o absoluta del aire como buena práctica. 6. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CALIBRACIÓN>CALIBRACIÓN EN AIRE. 7. Seleccione la opción de la señal de salida durante la calibración: Opción Descripción Activo Durante el proceso de calibración el instrumento envía el valor de medición actual de salida. Hold (Retenido) Durante el proceso de calibración el valor de salida del sensor se mantiene en el valor de medición actual. Transfer (Transferencia) Durante el proceso de calibración se envía un valor predeterminado. Consulte el manual del usuario del controlador para cambiar el valor predeterminado. 8. En el controlador se mostrará "Put the entire sensor in the bag with water." (Introduzca completamente el sensor en la bolsa con agua.). Deje que el valor se estabilice. Pulse ENTER (Intro) para aceptar el valor estable. También puede dejar que la calibración continúe hasta que en la pantalla se muestre "La tarea se ha realizado correctamente. ". 9. Cuando se haya calibrado el sensor, póngalo en proceso. Pulse ENTER (Intro). Figura 1 Procedimiento de calibración del aire Si el valor no se estabiliza, en la pantalla se mostrará el mensaje "Unable to Calibrate" (No se puede calibrar), seguido de un mensaje de error. En la Tabla 3 se muestran los mensajes de error y las soluciones para los problemas de calibración. Tabla 3 Mensajes de error de la calibración del aire Mensaje Descripción Resolución Error de calibración. Corrección de ganancia muy alta. El valor de ganancia calculado es demasiado elevado. Repita la calibración. Error de calibración. Corrección de ganancia muy baja. El valor de ganancia calculado es demasiado bajo. Repita la calibración. Error de calibración. Inestable El valor no se estabilizó en el tiempo máximo de calibración permitido. Repita la calibración. Español 23 Calibración por comparación. El método de calibración utiliza un sensor alternativo conectado a un medidor manual. 1. Ponga en funcionamiento el sensor alternativo. Coloque el segundo sensor lo más próximo posible al primer sensor. 2. Espere a que el valor de oxígeno disuelto se estabilice. 3. En el controlador para el primer sensor, vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CALIBRACIÓN>CALIBRACIÓN. 4. Seleccione la opción de la señal de salida durante la calibración: Opción Descripción Activo Durante el proceso de calibración el instrumento envía el valor de medición actual de salida. Hold (Retenido) Durante el proceso de calibración el valor de salida del sensor se mantiene en el valor de medición actual. Transfer (Transferencia) Durante el proceso de calibración se envía un valor predeterminado. Consulte el manual del usuario del controlador para cambiar el valor predeterminado. 5. En el controlador se mostrará: • "¿La lectura es estable?" • La medición actual de oxígeno disuelto • La medición actual de la temperatura 6. Cuando la medición sea estable, pulse INTRO. Se visualizará una pantalla de entrada. Nota: Normalmente, la medición se tarda en estabilizarse entre 2 y 3 minutos. Si el valor no se estabiliza, en la pantalla se mostrará el mensaje "Unable to Calibrate" (No se puede calibrar), seguido de un mensaje de error. En la Tabla 4 se muestran los mensajes de error y las soluciones para los problemas de calibración. Tabla 4 Mensajes de error de la calibración de muestra Mensaje Descripción Resolución Error de calibración. Compensación muy alta. El valor calculado de desvío es demasiado elevado. Repita la calibración. Error de calibración. Compensación muy baja. El valor calculado de desvío es demasiado bajo. Repita la calibración. Error de calibración. Inestable El valor no se estabilizó en el tiempo máximo de calibración permitido. Repita la calibración. Salida del proceso de calibración 1. Durante la calibración, pulse la tecla BACK (Atrás). Aparecerán tres opciones: Opción Descripción Cancelar Detiene el proceso de calibración. Se deberá comenzar con una nueva calibración desde el principio. Volver a la calibración Vuelve a la calibración actual. Salir Sale del proceso de calibración provisoriamente. Se puede acceder a otros menús mientras continúa la calibración. Se puede iniciar la calibración de un segundo sensor (en caso que lo hubiera). Para volver al proceso de calibración, pulse la tecla MENU (MENÚ) y seleccione Sensor Setup (Configuración del sensor), [seleccione el sensor]. 2. Seleccione una de las opciones. Confirme. 24 Español Restablecimiento de los valores predeterminados de la calibración La configuración de la calibración puede restablecerse con los valores predeterminados de fábrica. Los valores de ganancia y desvío se establecen al 1,0 y al 0,0, respectivamente. 1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CALIBRACIÓN>RESTABLECER CALIBRACIÓN. 2. En la pantalla se mostrará un mensaje de confirmación. Confirme que desea restablecer el sensor con la curva de calibración predeterminada de fábrica. Mantenimiento PELIGRO Peligros diversos. Sólo el personal cualificado debe realizar las tareas descritas en esta sección del documento. PELIGRO Peligro de explosión. Evite conectar o desconectar componentes o circuitos eléctricos sin antes desconectar la alimentación eléctrica, a menos que se sepa que esa porción del equipo no presenta riesgos. PELIGRO Peligro de explosión. Es posible que la sustitución de algún componente perjudique a la conformidad con la Clase 1, División 2. Evite conectar o desconectar ningún componente sin antes desconectar la alimentación eléctrica, a menos que se sepa que esa zona no presenta riesgos. AVISO La versión con certificación para ubicaciones peligrosas de este producto no cumple los requisitos de la Directiva 94/9/EC (Directiva ATEX). Cronograma de mantenimiento En el cronograma de mantenimiento se muestran los intervalos mínimos de las tareas periódicas de mantenimiento. En las aplicaciones donde el electrodo se ensucia, realice las tareas de mantenimiento con mayor frecuencia. Nota: No desmonte la sonda para su mantenimiento o limpieza. Tarea de mantenimiento Frecuencia mínima recomendada Limpiar el sensor 90 días Inspección del sensor en busca de daños 90 días Calibración del sensor Según lo recomendado por su sistema de control de calidad o entes regulatorios locales Limpiar el sensor Limpie la parte exterior del sensor con un paño suave y húmedo. Nota: Si debe retirar la cápsula del sensor para limpiarla, no exponga directamente la parte interior de la cápsula a la luz solar durante un período de tiempo prolongado. Configuración y cambio del intervalo de limpieza En función de las condiciones de la aplicación del sensor, los intervalos de tiempo que transcurren entre las limpiezas del sensor manual pueden ser menores o mayores. El intervalo de limpieza predeterminado es de 0 días. Para cambiar el intervalo, consulte los pasos de este procedimiento. Español 25 1. Vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>CONFIGURACIÓN>CLEANING INTERVAL (Intervalo de limpieza). 2. Cambie el valor mostrado según sea necesario. Confirme el cambio. • Para desactivar el intervalo de limpieza, establezca el valor en "0". Sustitución de la cápsula del sensor ADVERTENCIA Posible riesgo de explosión. La cápsula de configuración del sensor no se ha evaluado para ser utilizada en ubicaciones peligrosas. Junto con las instrucciones de instalación se suministran cápsulas para el sensor y cápsulas de configuración de repuesto. Para cambiar la cápsula, consulte las instrucciones suministradas. Después de instalar la nueva cápsula del sensor, asegúrese de que el número de lote de la cápsula del sensor es el mismo número de lote de la cápsula del sensor es el mismo número que se puede leer por Modbus. El sensor utiliza la información de calibración de la cápsula del sensor. Para obtener un mejor rendimiento y precisión, sustituya la cápsula del sensor: • Cada dos añoso con mayor frecuencia si es necesario. • Cuando en las inspecciones periódicas se detecte una erosión importante en la cápsula del sensor. Solución de problemas Menú de prueba y diagnóstico En el menú de prueba y diagnóstico se muestra la información actual e histórica relativa al sensor LDO. Para acceder al menú de prueba y diagnóstico, vaya a MENU (Menú)>CONFIGURACIÓN DEL SENSOR>[Seleccione el sensor]>MANTENIMIENTO. Consulte la Tabla 5. Tabla 5 Menú Mantenimiento Opción Descripción Información del sensor Versión de software: muestra la versión de software instalada Programa de arranque: muestra la versión de programa de arranque instalada Versión de controlador: muestra la versión de controlador de software instalada Sensor cap lot code (Código de lote de la cápsula del sensor) Muestra el lote de fabricación de la cápsula del sensor. Número de serie Número de serie del sensor Corrección de ganancia Ajusta el valor de ganancia de la calibración. Intervalo: de 0,50 a 2,00 Corrección de compensación Ajusta el valor de desvío de la calibración (mg/l o ppm). Diagnósticos de fase Muestra la fase de las longitudes de onda totales, rojas y azules. Actualiza una por segundo. Diagnósticos de amplitud Muestra la amplitud de las longitudes de onda rojas y azules. Actualiza una por segundo. 26 Español Intervalo: de -3,00 a +3,00 Tabla 5 Menú Mantenimiento (continúa) Opción Descripción Days remaining to clean (Días hasta próxima limpieza) Muestra el número de días que quedan hasta la próxima limpieza manual programada. Sensor life (Duración del sensor) Muestra el número de días que quedan hasta la próxima sustitución programada de la cápsula del sensor.. Lista de errores Si se produce un error, la lectura de la pantalla de medición se iluminará. Los ajustes del controlador determinan la conducta de la salida. Para obtener información detallada, consulte el manual del controlador. Para ver los errores del sensor actual, vaya a MENU (Menú)>DIAGNÓSTICOS DEL SENSOR>[Seleccione el sensor]>LISTA DE ERRORES. Consulte la Tabla 6. Tabla 6 Lista de errores del sensor LDO Error Posible causa Resolución Amplitud roja muy baja. (El valor es inferior a 0,01) La cápsula del sensor no está instalada o no se ha instalado correctamente. Retire la cápsula del sensor y vuélvala a instalar. El recorrido de la luz se ha bloqueado en la cápsula del sensor. Inspeccione el interior de la cápsula y de la lente del sensor. El sensor no funciona correctamente. Asegúrese de que el LED se ilumina. Póngase en contacto con el fabricante. o Amplitud azul muy baja. (El valor es inferior a 0,01) Lista de advertencias Cuando el icono de advertencia se ilumina (sc100 y sc200) o cuando el color de la pantalla cambia a amarillo (sc1000), aparece un mensaje en la parte inferior de la pantalla de medición. En el sc1000, el color de la pantalla se cambia a amarillo para mostrar una advertencia. Para ver las advertencias del sensor actual, vaya a MENU (Menú)>DIAGNÓSTICOS DEL SENSOR>[Seleccione el sensor]>LISTA DE ADVERTENCIAS. Consulte la Tabla 7. Tabla 7 Lista de advertencias del sensor Advertencia Definición Resolución Error de configuración de EEPROM El almacenamiento se ha dañado. Los valores se han establecido a los valores predeterminados de fábrica. Póngase en contacto con la asistencia técnica. Error de EEPROM Temperatura <0 °C La temperatura del proceso se encuentra Aumente la temperatura del proceso o por debajo de 0 °C (32 °F). deténgalo hasta que la temperatura se encuentre dentro del intervalo del sensor indicado en las especificaciones. Temperatura >50 °C La temperatura del proceso se encuentra Disminuya la temperatura del proceso o por encima de 50 °C (120 °F). deténgalo hasta que la temperatura se encuentre dentro del intervalo del sensor indicado en las especificaciones. Amplitud roja muy baja. El valor cae por debajo de 0,03. Consulte Lista de errores en la página 27 . Amplitud roja muy alta. El valor es superior a 0,35. Póngase en contacto con la asistencia técnica. Español 27 Tabla 7 Lista de advertencias del sensor (continúa) Advertencia Definición Resolución Amplitud azul muy baja. El valor se encuentra por debajo de 0,03. Consulte la Lista de errores en la página 27. Amplitud azul muy alta. El valor es superior a 0,35. Póngase en contacto con la asistencia técnica. Sensor cap lot code missing. (Falta el código de lote de la cápsula del sensor.) El código de la cápsula del sensor se ha dañado. Se ha restablecido automáticamente el código con los códigos predeterminados del lote y la cápsula. Finalice el procedimiento de la cápsula de configuración del sensor. Si no hay ninguna cápsula de configuración disponible para la cápsula del sensor, póngase en contacto con la asistencia técnica. Lista de eventos La lista de eventos guarda un registro de los cambios en la forma en la que el sensor registra los datos. Para ver los eventos del sensor, vaya a MENU (Menú)>DIAGNÓSTICOS DEL SENSOR>[Seleccione el sensor]>EVENT LIST (Lista de eventos). Consulte la Tabla 8. Tabla 8 Lista de eventos del sensor Evento Descripción Altitude/Pressure unit change (Cambio de unidad de altitud/presión) Se han modificado las unidades de la presión atmosférica o de la altitud. Altitude/Pressure change (Cambio de altitud/presión) Se ha modificado el valor de la altitud o de la presión atmosférica. Temperature change (Cambio de temperatura) Se han modificado las unidades de la temperatura. Unit change (Cambio de unidad) Se ha modificado una unidad nueva de medición. Salinity change (Cambio de salinidad) Se ha modificado el valor de salinidad. Restablecimiento Se ha restablecido la configuración del sensor a los valores predeterminados. Sensor setup change (Cambio de configuración del sensor) Se ha modificado la configuración del sensor. Cleaning interval change (Cambio de intervalo de limpieza) Se ha modificado el intervalo de tiempo que transcurre entre las limpiezas del sensor. Sensor life change (Cambio de duración del sensor) Se ha modificado el intervalo de tiempo que transcurre entre las sustituciones de la cápsula del sensor. 28 Español Fonctionnement Configuration du capteur Utilisez le menu Configuration pour saisir les informations d'identification du capteur et modifier les options de traitement et de stockage des données. Veuillez consulter le manuel d'utilisation pour des informations sur l'installation du capteur. Assurez-vous que les valeurs du menu Configuration soient conformes à l'application. 1. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >CONFIGURATION. 2. Sélectionnez une option, puis appuyez sur ENTER (ENTREE). Le tableau ci-dessous présente les options disponibles. Option Description Nom Modifie le nom correspondant au capteur en haut de l'écran de mesure. Le nom est limité à 10 caractères avec n'importe quelle combinaison de lettres, chiffres, espaces ou ponctuation. Unité Température : définit les unités de température en °C (valeur par défaut) ou °F. Mesure : définit les unités de mesure en mg/L, ppm ou %. Altitude/pression : définit l'altitude en m ou ft, ou les unités de pression atmosphérique en mmHg ou torr. (Valeur par défaut = 0 pied.) Alt./Pression Saisissez la valeur d'altitude ou de pression atmosphérique. Il est nécessaire que cette valeur soit précise afin d'effectuer les mesures de saturation en pourcentage et l'étalonnage dans l'air. (Valeur par défaut = 0 pied.) Salinité Saisissez la valeur de salinité. Plage de salinité : 0 à 250 parties par milliers (‰). (Valeur par défaut = 0 pied.) Moyenne du signal Définissez l'intervalle de temps pour la moyenne du signal en secondes. Intervalle de nettoyage Définissez l'intervalle de temps pour le nettoyage manuel du capteur en jours. (Valeur par défaut = 0 jour. Une valeur de 0 jour désactive l'intervalle de nettoyage.) Réinitialiser l'intervalle de nettoyage Définissez le dernier intervalle de nettoyage enregistré comme intervalle de temps. Intervalle de l'enregistreur de données Définit l'intervalle de temps pour l'enregistrement des données dans le journal des données ; 0,5, 1, 2, 5, 10, 15 (par défaut), 30, 60 minutes. Réinitialiser Restaure les valeurs par défaut des options de configuration du capteur. Les réglages de pente et de décalage ne sont pas affectés. Saisie de la valeur de pression atmosphérique Le réglage par défaut pour la pression atmosphérique (de l'air) est 0 pied, soit le niveau de la mer. Pour modifier la valeur par défaut, procédez comme suit. Il est possible d'ajuster la pression d'air à l'aide d'une valeur d'altitude ou d'unités de pression (recommandée). Remarque : La précision de la pression de l'air est essentielle pour l'étalonnage de l'air saturé. Utilisez toujours la valeur de pression absolue, et non la valeur ajustée. Si vous ne connaissez pas la valeur de pression d'air absolue, utilisez l'altitude exacte de l'endroit où se trouve le capteur. 1. Allez dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >CONFIGURATION >CHOIX UNITES >PRESS. AIR/ALT. 2. Sélectionnez une des unités suivantes : Option Description Altit. (pied) Pied (foot) : unité de mesure anglo-saxonne de l'altitude Français 29 Option Description Altit. (mètre) Mètre : unité de mesure de l'altitude Pression d'air mmHg Millimètres de mercure : unité de mesure de la pression d'air absolue Pression d'air torr Unité de mesure de pression d'air absolue 3. Confirmez la sélection. L'écran de saisie de valeur affiche les unités sélectionnées. 4. Saisissez la valeur et confirmez. Saisie d'une valeur de correction de la salinité Il est possible que la valeur DO affichée par les mesures d'oxygène dissous des échantillons salins soit très différente de la valeur DO réelle. Pour compenser l'effet des sels dissous dans un échantillon, saisissez un facteur de correction de la salinité. Remarque : Si vous n'êtes pas certain du taux de salinité du fluide, renseignez-vous auprès des ingénieurs du site de traitement. 1. A l'aide d'un conductimètre, mesurez la conductivité de l'échantillon en mS/cm à la température de référence de 20 °C. 2. Aidez-vous du Tableau 1 pour estimer le facteur de correction de la salinité en fonction de la saturation en parties par millier (‰). Remarque : La concentration en ion chlorure, exprimée en g/kg, indique la chlorinité de l'échantillon. Le taux de salinité est calculé selon la formule suivante : salinité = 1,80655 x chlorinité. Il est possible de calculer le taux de salinité à l'aide de la relation établie dans la section 2520 B du document Standard Methods for the Examination of Water and Wastewater.1, 3. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >CONFIGURATION >SALINITE. 4. Saisissez le facteur de salinité et confirmez votre saisie. Tableau 1 Saturation de salinité (‰) en fonction de la valeur de conductivité (mS/cm) 1 mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Standard Methods for the Examiniation of Water and Wastewater, 20e édition. Editeurs : Lenore S. Clesceri, Arnold E. Greenberg et Andrew D. Eaton, p. 2-48-2-29 (1998). Le rapport entre chlorinité et solubilité de l'oxygène est fourni dans ce même document à la section 4500-O:I p. 4-131. 30 Français Etalonnage pour les mesures Le capteur est étalonné en usine conformément aux spécifications. Le fabricant recommande de procéder à l'étalonnage à la fréquence préconisée par les organismes de contrôle. Si l'étalonnage est nécessaire, assurez-vous du fonctionnement stabilisé du capteur avant de procéder à l'étalonnage. Ne procédez pas à l'étalonnage du capteur lors de son installation. Le Tableau 2 présente les options d'étalonnage. Tableau 2 Options d'étalonnage Option Désignation Etalonnage à l'air libre Méthode d'étalonnage recommandée. Cet étalonnage modifie la pente. Etalonnage Etalonnage par comparaison avec un appareil de mesure d'oxygène dissous portable. Cet étalonnage modifie le décalage. Réinit. étal. Rétablit les valeurs de gain d'étalonnage (pente) et de décalage par défaut ; gain par défaut = 1,0, décalage par défaut = 0,0 Etalonnage à l'air libre Remarques à l'intention de l'utilisateur : • • • • Assurez-vous que le sachet utilisé pour l'étalonnage contient bien de l'eau. Assurez-vous que le joint placé entre le sachet d'étalonnage et le corps du capteur est bien serré. Avant de procéder à l'étalonnage, assurez-vous que le capteur est bien sec. Assurez-vous que le réglage de pression d'air et d'altitude est approprié à l'emplacement choisi pour effectuer l'étalonnage. • Attendez que la température du capteur corresponde à la température de l'emplacement du sachet d'étalonnage. Jusqu'à 15 minutes peuvent être nécessaires pour réduire un écart de température important entre le fluide traité et l'emplacement choisi pour l'étalonnage. 1. Sortez le capteur du fluide traité. Nettoyez le capteur à l'aide d'un chiffon humide. 2. Placez l'intégralité du capteur dans un sachet d'étalonnage contenant 25 à 50 ml d'eau. Veillez à ce que la capsule du capteur n'entre pas en contact avec l'eau du sachet d'étalonnage et ne comporte aucune goutte d'eau. 3. Resserrez le sac autour du corps du capteur à l'aide d'un ruban adhésif, d'une ficelle ou de votre main. 4. Avant de procéder à l'étalonnage, laissez le capteur se stabiliser pendant 15 minutes. Pendant la stabilisation, conservez le sachet d'étalonnage à l'abri du soleil. 5. Assurez-vous que le réglage actuel absolu de pression d'air ou d'altitude est correctement configuré. Remarque : le fabricant recommande l'utilisation de la valeur de pression d'air réelle ou absolue. 6. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >ETALONNAGE >ETALON. A L'AIR 7. Sélectionnez l'option de sortie du signal pendant l'étalonnage : Option Description Actif L'instrument envoie la valeur de sortie mesurée pendant la procédure d'étalonnage. Mémorisation La valeur de sortie du capteur est maintenue à la dernière valeur mesurée pendant la procédure d'étalonnage. Transfert Une valeur prédéfinie est fournie pendant l'étalonnage. Consultez le manuel d'utilisation du transmetteur pour changer la valeur prédéfinie. Français 31 8. Le transmetteur indiquera « Placer l'ensemble du capteur dans le sac avec l'eau ». Attendez que la valeur se stabilise. Appuyez sur ENTER (ENTREE) pour accepter la valeur stable. Sinon, laisser continuer l'étalonnage jusqu'à l'affichage de « La tâche a été réalisée avec succès ». 9. Une fois le capteur étalonné, placez-le dans le fluide traité. Appuyez sur ENTER (ENTREE). Figure 1 Procédure d'étalonnage à l'air Si la valeur ne se stabilise pas, l'écran affiche un message d'erreur précédé de la mention « Unable to Calibrate » (Etalonnage impossible). Le Tableau 3 présente les messages d'erreur et les résolutions des problèmes d'étalonnage. Tableau 3 Messages relatifs à l'étalonnage à l'air Message Description Résolution Echec de l'étalonnage ! La correction de gain est trop élevée. La valeur de gain calculée est trop élevée. Procédez à nouveau à l'étalonnage. Echec de l'étalonnage ! La correction de gain est trop faible. La valeur de gain calculée est trop faible. Procédez à nouveau à l'étalonnage. Echec de l'étalonnage ! Instable La valeur ne s'est pas stabilisée dans le délai maximal d'étalonnage. Procédez à nouveau à l'étalonnage. Etalonnage par comparaison Cette méthode d'étalonnage nécessite un autre capteur connecté à un appareil de mesure portable. 1. Plongez cet autre capteur dans le fluide. Placez le second capteur aussi près que possible du premier. 2. Attendez la stabilisation de la valeur d'oxygène dissous. 3. Sur le transmetteur pour le premier capteur, allez dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >ETALONNAGE >ETALONNAGE. 4. Sélectionnez l'option de sortie du signal pendant l'étalonnage : Option Description Actif L'instrument envoie la valeur de sortie mesurée pendant la procédure d'étalonnage. Mémorisation La valeur de sortie du capteur est maintenue à la dernière valeur mesurée pendant la procédure d'étalonnage. Transfert 32 Français Une valeur prédéfinie est fournie pendant l'étalonnage. Consultez le manuel d'utilisation du transmetteur pour changer la valeur prédéfinie. 5. Le transmetteur affiche les éléments suivants : • « La lecture est-elle stable ? » • La mesure d'oxygène dissous actuelle • La mesure de température actuelle 6. Une fois la mesure stable, appuyez sur ENTER (ENTREE). Un écran de saisie s'affiche. Remarque : la mesure se stabilise en général au bout de 2 ou 3 minutes. Si la valeur ne se stabilise pas, l'écran affiche un message d'erreur précédé de la mention « Unable to Calibrate » (Etalonnage impossible). Le Tableau 4 présente les messages d'erreur et les résolutions des problèmes d'étalonnage. Tableau 4 Messages d'erreur d'étalonnage par échantillon Message Description Résolution Echec de l'étalonnage ! Le décalage est trop élevé. La valeur de décalage calculée est trop élevée. Procédez à nouveau à l'étalonnage. Echec de l'étalonnage ! Le décalage est trop faible. La valeur de décalage calculée est trop faible. Procédez à nouveau à l'étalonnage. Echec de l'étalonnage ! Instable La valeur ne s'est pas stabilisée dans le délai maximal d'étalonnage. Procédez à nouveau à l'étalonnage. Quitter la procédure d'étalonnage 1. Pendant l'étalonnage, appuyez sur la touche BACK (RETOUR). Trois options apparaissent : Option Description Annuler Arrête l'étalonnage. Un nouvel étalonnage devra repartir du début. Revenir à l'étalonnage Permet de reprendre l'étalonnage en cours. Quitter Quitte temporairement l'étalonnage. L'étalonnage se poursuit en arrière-plan, permettant l'accès à d'autres menus. Il est possible de démarrer un étalonnage pour un deuxième capteur (le cas échéant). Pour revenir à l'étalonnage, appuyez sur la touche MENU et sélectionnez Sensor Setup (Config capteur), [Sélectionnez le capteur]. 2. Sélectionnez une des options. Validez. Réinitialisation des valeurs d'étalonnage par défaut Il est possible de réinitialiser les réglages d'étalonnage à l'aide des valeurs par défaut. Les valeurs de gain et de décalage sont alors définies sur 1 et 0, respectivement. 1. Allez dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >ETALONNAGE >REINIT. ETAL. 2. Un message de confirmation s'affiche. Confirmez la réinitialisation du capteur à l'aide de la courbe d'étalonnage par défaut. Maintenance DANGER Dangers multiples. Seul le personnel qualifié doit effectuer les tâches détaillées dans cette section du document. Français 33 DANGER Risque d'explosion. Ne branchez ni ne débranchez aucun composant électrique ou circuit sur l'équipement avant de vous être assuré que l'alimentation a été coupée et que l'emplacement est sécurisé. DANGER Risque d'explosion. Tout changement de composant est susceptible d'avoir une incidence sur la conformité Classe 1, Division 2. Ne remplacez jamais un composant avant de vous être assuré que l'alimentation a été coupée et que l'emplacement est sécurisé. AVIS La version de ce produit certifiée pour les environnements dangereux n'est pas conforme à la norme 94/9/EC (norme ATEX). Calendrier de maintenance Le calendrier de maintenance indique la fréquence minimum des tâches de maintenance régulières. Effectuer les opérations d'entretien plus fréquemment avec des applications entraînant une contamination de l'électrode. Remarque : ne démontez pas la sonde pour la maintenance ou le nettoyage. Tâche de maintenance Fréquence minimum recommandée Nettoyage du capteur 90 jours Inspection du capteur 90 jours Etalonnage du capteur Conformément aux recommandations des organismes de contrôle Nettoyage du capteur Nettoyez la surface du capteur à l'aide d'un chiffon doux humide. Remarque : S'il est nécessaire de retirer la capsule du capteur lors du nettoyage, évitez d'exposer l'intérieur de la capsule aux rayons du soleil pendant une période prolongée. Définition ou modification de l'intervalle de nettoyage L'intervalle adéquat entre les nettoyages manuels du capteur peut varier en fonction des conditions d'utilisation. L'intervalle de nettoyage par défaut est de 0 jour. Pour modifier l'intervalle, procédez comme suit. 1. Allez dans MENU >PROGR. CAPTEUR > [Sélectionner le capteur] >CONFIGURATION >INTERV NETTOYAGE. 2. Modifiez la valeur affichée. Confirmez la modification. • Pour désactiver l'intervalle de nettoyage, définissez 0 comme valeur. Remplacement du capuchon du capteur AVERTISSEMENT Risque d'explosion. Le capuchon de configuration du capteur n'est pas certifié pour une utilisation en environnement dangereux. Des instructions d'installation sont fournies avec les capuchons de configuration et les capuchons de capteur de rechange. Pour remplacer le capuchon, reportez-vous aux instructions fournies. Une fois le capuchon du nouveau capteur installé, assurez-vous que le numéro de lot figurant sur le capuchon du capteur est identique à celui qui est lu par Modbus. Le capteur utilise les informations d'étalonnage qui figurent sur ce capuchon. 34 Français Pour bénéficier de performances et d'une précision optimales, remplacez le capuchon du capteur : • Tous les deux ans ;ou plus si nécessaire • Lorsque l'inspection de routine révèle une forte érosion du capuchon du capteur. Dépannage Menu de diagnostic et test Le menu de diagnostic et de test affiche les informations actuelles et consignées relatives au capteur LDO. Pour accéder au menu de diagnostic et de test, rendez-vous dans MENU >PROGR. CAPTEUR >[Sélectionner le capteur] >DIAG/TEST. Reportez-vous à Tableau 5. Tableau 5 Menu Diag/Test Option Description Informations de capteur Version du logiciel : affiche la version du logiciel installé Programme de démarrage : indique la version du programme de démarrage installé Version du pilote : indique la version du pilote installé Numéro de lot du bouchon du capteur Affiche le lot de fabrication du capuchon du capteur N° de série Numéro de série du capteur Corr. gain Permet d'ajuster la valeur de gain d'étalonnage. Plage : 0,5 à 2 Corr. zéro Permet d'ajuster la valeur de décalage d'étalonnage (mg/l ou ppm). Plage : -3 à 3 Diag. phase Affiche la phase des longueurs d'onde bleue, rouge et totale. Mise à jour chaque seconde. Diagn. amplit. Affiche l'amplitude des longueurs d'onde bleue et rouge. Mise à jour chaque seconde. Jours restants avant le nettoyage Affiche le nombre de jours avant le prochain nettoyage manuel programmé. Durée de vie du capteur Affiche le nombre de jours avant le prochain remplacement de capuchon du capteur programmé.. Liste d’erreurs En cas d'erreur, la mesure affichée clignote. Le comportement de sortie est déterminé par les réglages du transmetteur. Pour plus d'informations, reportez-vous au manuel du transmetteur. Français 35 Pour afficher les erreurs de capteur actuelles, allez dans MENU >DIAGN. CAPTEUR >[Sélectionner le capteur] >LISTE ERREURS. Reportez-vous à Tableau 6. Tableau 6 Liste d'erreurs du capteur LDO Erreur Cause possible Résolution L'amplitude rouge est trop faible. (La valeur est inférieure à 0,01) Le capuchon du capteur n'est pas installé ou ne l'est pas correctement. Retirez le capuchon du capteur, puis replacez-le. La trajectoire de la lumière est bloquée dans le capuchon du capteur. Inspectez la lentille et l'intérieur du capuchon du capteur. Le capteur ne fonctionne pas correctement. Assurez-vous que le voyant clignote. Contactez le fabricant. ou L'amplitude bleue est trop faible. (La valeur est inférieure à 0,01) Liste d’avertissements Lorsque l'icône d'avertissement clignote (sc100 et sc200) ou lorsque l'écran devient jaune (sc1000), un message s'affiche en bas de l'écran. Sur le transmetteur sc1000, l'écran devient jaune lorsqu'un avertissement est affiché. Pour afficher les avertissements actuels des capteurs, allez dans MENU >DIAGN. CAPTEUR > [Sélectionner le capteur] >LISTE AVERTIS. Reportez-vous à Tableau 7. Tableau 7 Liste d'avertissements du capteur Avertissement Définition Résolution Err. progr. EEPR Le stockage est corrompu. Les valeurs par défaut ont été rétablies. Contactez l’assistance technique. Température < 0 °C La température du fluide est inférieure à 0 °C Augmentez la température du fluide ou cessez son utilisation jusqu'à ce que sa température soit comprise dans la plage des spécifications du capteur. Température > 50 °C La température du fluide est supérieure à 50 °C Diminuez la température du fluide ou cessez son utilisation jusqu'à ce que sa température soit comprise dans la plage des spécifications du capteur. L'amplitude rouge est trop faible. La valeur est inférieure à 0,03 Voir le Liste d’erreurs à la page 35. L'amplitude rouge est trop élevée. La valeur est supérieure à 0,35 Appelez l'assistance technique. L'amplitude bleue est trop faible. La valeur est inférieure à 0,03 Reportez-vous à Liste d’erreurs à la page 35. L'amplitude bleue est trop élevée. La valeur est supérieure à 0,35 Appelez l'assistance technique. Numéro de lot du bouchon de capteur manquant. Le code du capuchon du capteur est corrompu. Le code a été automatiquement réinitialisé à l'aide des codes de lot et de capuchon par défaut. Suivez les instructions relatives au capuchon de configuration du capteur. Si aucun capuchon de configuration n'est disponible pour le capuchon du capteur, contactez l'assistance technique. Err. res. EEPR 36 Français Liste d'événements La liste d'événements consigne les modifications apportées au mode d'enregistrement des données par le capteur. Pour afficher les événements des capteurs, allez dans MENU >DIAGN. CAPTEUR >[Sélectionner le capteur] >LISTE EVENEMENTS. Reportez-vous à Tableau 8. Tableau 8 Liste d'événements du capteur Evénement Description Changement des unités d'altitude/pression Les unités de pression atmosphérique ou d'altitude ont été modifiées. Changement d'altitude/pression La valeur de pression atmosphérique ou d'altitude a été modifiée. Changement de température Les unités de température ont été modifiées. Changement de l'unité Une nouvelle unité de mesure a été introduite. Changement de salinité La valeur de salinité a été modifiée. Réinitialiser Les valeurs par défaut des réglages du capteur ont été rétablies. Changement de configuration du capteur La configuration du capteur a été modifiée. Changement d'intervalle de nettoyage L'intervalle entre deux nettoyages du capteur a été modifié. Changement de la durée de vie du capteur L'intervalle entre deux remplacements du capuchon du capteur a été modifié. Français 37 Funzionamento Configurazione del sensore Utilizzare il menu Configurazione per inserire i dati di identificazione del sensore e modificare le opzioni per la gestione e la conservazione dei dati. Per informazioni sull'installazione del sensore, fare riferimento al manuale utente. Verificare che tutti i valori del menu Configurazione siano corretti per la specifica applicazione. 1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE. 2. Selezionare un'opzione e premere ENTER. Nella tabella seguente è riportato l'elenco delle opzioni disponibili. Opzione Descrizione Nome Consente di modificare il nome del sensore visualizzato sulla parte superiore della schermata di misurazione. Il nome è limitato a 10 caratteri in una combinazione qualsiasi di lettere, numeri, spazi e punteggiatura. Unità Temperatura - Consente di impostare le unità della temperatura su °C (predefinito) o °F. Misura - Consente di impostare le unità di misura su mg/l, ppm o %. Alt/Press - Consente di impostare l'altitudine in metri o piedi, oppure di impostare le unità della pressione atmosferica in mmHg o torr. (Valore predefinito = 0 piedi) Alt/Press Consente di immettere il valore dell'altitudine o della pressione atmosferica. Questo valore deve essere accurato per eseguire le misurazioni di saturazione percentuale e la calibrazione in aria. (Valore predefinito = 0 piedi) Salinità Consente di immettere il valore di salinità. Intervallo di salinità: da 0.00 a 250.00 parti per migliaia (‰). (Valore predefinito = 0) Media segnale Consente di impostare l'intervallo in secondi per il calcolo della media dei segnali. Cleaning interval (Intervallo di pulizia) Consente di impostare l'intervallo di tempo per la pulizia manuale del sensore in giorni. (Valore predefinito = 0 giorni. Il valore 0 giorni disabilita l'intervallo di pulizia) Reset cleaning interval (Reset intervallo di pulizia) Consente di impostare l'intervallo di tempo per la pulizia sull'ultimo valore salvato. Sen/Interval Consente di impostare l'intervallo di tempo per la memorizzazione dei dati nel registro: 0.5, 1, 2, 5, 10, 15 (predefinito), 30 e 60 minuti. Ripr config Consente di ripristinare i valori predefiniti configurabili per il sensore. Non modifica l'impostazione di slope o offset. Immissione del valore di pressione atmosferica L'impostazione predefinita per la pressione atmosferica (aria) è di 0 piedi o livello del mare. Per modificare il valore predefinito eseguire questa procedura. La regolazione della pressione dell'aria si immette sia come altitudine sia sotto forma di unità di pressione (opzione preferenziale). Nota: l'accuratezza della pressione dell'aria è essenziale per la calibrazione dell'aria satura. Utilizzare solo la pressione assoluta e non quella regolata. Se la pressione assoluta non è nota, utilizzare l'altitudine corretta del sito di installazione. 1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>UNITÀ>PRESS/ALT ARIA. 2. Selezionare una delle opzioni elencate: Opzione Descrizione Alt in piedi Piedi - Unità di misura dell'altitudine 38 Italiano Opzione Descrizione Alti in metri Metri - Unità di misura metrica dell'altitudine Press aria mmHg Millimetri di mercurio - Unità di misura metrica della pressione assoluta Press aria torr Unità di misura per la pressione assoluta dell'aria 3. Confermare la selezione. La schermata di immissione dei valori visualizzerà le unità selezionate. 4. Immettere il valore e confermare. Immissione del valore di correzione della salinità Le misurazioni dell'ossigeno disciolto nei campioni salini possono indicare un valore di OD apparente che in realtà è molto distante da quello effettivo. Per correggere l'influenza esercitata dai sali disciolti sul campione, immettere un fattore di correzione della salinità. Nota: se la presenza o la quantità di salinità nel processo non sono note, rivolgersi al personale tecnico dell'impianto di trattamento. 1. Per misurare la conduttività del campione in mS/cm ad una temperatura di riferimento di 20 °C (68 °F), utilizzare un misuratore di conduttività. 2. Per stimare il fattore di correzione della salinità in parti per migliaia (‰) di saturazione, utilizzare la Tabella 1. Nota: la concentrazione di ioni di cloruro in g/kg è uguale alla clorinità del campione. La salinità viene calcolata sulla base della formula seguente: Salinità = 1,80655 × clorinità. È possibile calcolare la salinità mediante il rapporto riportato nella sezione 2520 B di Standard Methods for the Examination of Water and Wastewater.1, 3. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>SALINITÀ. 4. Immettere il fattore di correzione della salinità e confermare. Tabella 1 Saturazione di salinità (‰) per valore di conduttività (mS/cm) 1 mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Standard Methods for the Examiniation of Water and Wastewater (Metodi standard per l'analisi di acque e acque reflue), 20esima edizione. Editors Lenore S. Clesceri, Arnold E. Greenberg and Andrew D. Eaton, pagg. 2-48-2-29 (1998). La relazione fra clorinità e solubilità dell'ossigeno è riportata nel medesimo documento di riferimento in 4500-O:I pagg. 4-131. Italiano 39 Calibrazione per le misurazioni Il sensore viene calibrato dal produttore in base alle specifiche. Il produttore non consiglia di eseguire la calibrazione a meno che gli enti di regolamentazione non richiedano periodicamente tale operazione. Se è necessario eseguire la calibrazione, prima di avviarla attendere che il sensore si stabilizzi nel processo. Non eseguire la calibrazione del sensore in fase di impostazione. Nella Tabella 2 sono riportate le opzioni per la calibrazione. Tabella 2 Opzioni di calibrazione Opzione Descrizione Aria calibraz Metodo di calibrazione consigliato. Questa calibrazione modifica lo slope. Curva di Calibrazione tramite confronto con un ossimetro portatile. Questa calibrazione modifica l'offset. Reimpostaz ca Ripristina il guadagno di calibrazione (slope) e l'offset ai valori predefiniti dal produttore: guadagno predefinito = 1.0; offset predefinito = 0.0 Aria calibraz Note per l'utente: • • • • Accertarsi che nella sacca di calibrazione sia presente l'acqua. Accertarsi che il corpo del sensore sia perfettamente sigillato all'interno della sacca di calibrazione. Quando si esegue la calibrazione verificare che il sensore sia asciutto. Accertarsi che l'impostazione della pressione dell'aria/altitudine sia accurata per la posizione di calibrazione. • Attendere che la temperatura del sensore si stabilizzi su quella della posizione della sacca di calibrazione. In caso di differenza di temperatura significativa fra il processo e la posizione di calibrazione, la stabilizzazione può richiedere fino a 15 minuti. 1. Rimuovere il sensore dal processo. Pulire il sensore con un panno bagnato. 2. Inserire tutto il sensore in una sacca di calibrazione con 25-50 ml di acqua. Accertarsi che il cappuccio del sensore non sia a contatto con l'acqua all'interno della sacca di calibrazione e che sul cappuccio del sensore non siano presenti gocce d'acqua. 3. Utilizzare un elastico, una fascetta o la mano per creare una tenuta ermetica intorno al corpo del sensore. 4. Prima di eseguire la calibrazione, attendere 15 minuti in modo che il sensore si stabilizzi. Durante questa fase di stabilizzazione non esporre la sacca alla luce diretta del sole. 5. Assicurarsi che la pressione assoluta dell'aria o l'altitudine sia configurata correttamente. Nota: Il produttore consiglia di utilizzare come miglior prassi la pressione assoluta o effettiva dell'aria. 6. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CALIBRAZIONE>ARIA CALIBRAZ. 7. Selezionare l'opzione per il segnale di output durante la calibrazione: Opzione Descrizione Attivo Lo strumento invia il valore di output misurato corrente durante la procedura di calibrazione. Hold (Memorizza) Il valore di output del sensore viene tenuto al valore misurato corrente durante la procedura di calibrazione. Transfer (Trasmetti) Durante la calibrazione viene inviato un valore predefinito. Per modificare il valore predefinito, fare riferimento al manuale dell'utente del controller. 8. Il controller visualizza "Inserire l'intero sensore nella sacca con acqua.". Attendere che il valore si stabilizzi. Premere ENTER per accettare il valore stabile. In alternativa, lasciare che la calibrazione continui finché sul display non viene visualizzato "Attività completata correttamente. ". 9. Dopo aver completato la calibrazione, posizionare il sensore nel processo. Premere ENTER. 40 Italiano Figura 1 Procedura di calibrazione in aria Se il valore non si stabilizza, appare la segnalazione "Unable to Calibrate" (Impossibile eseguire la calibrazione) seguita da un messaggio di errore. Nella Tabella 3 sono riportati i messaggi di errore e le soluzioni dei problemi di calibrazione. Tabella 3 Messaggi di errore per la calibrazione in aria Messaggio Descrizione Risoluzione Cal non corret Gain alto. Il guadagno calcolato è troppo alto. Ripetere la calibrazione. Cal non corret Gain inferiore. Il guadagno calcolato è troppo basso. Ripetere la calibrazione. Cal non corret Instabile Ripetere la calibrazione. Il valore non si è stabilizzato durante il tempo di calibrazione massimo consentito. Calibrazione per confronto Questo metodo di calibrazione utilizza un sensore alternativo collegato ad un ossimetro portatile. 1. Inserire il sensore alternativo nel processo. Posizionare il secondo sensore il più vicino possibile al primo. 2. Attendere che il DO valore si stabilizzi. 3. Sul controller del primo sensore, scegliere MENU>SETUP SONDA>[Scelta sensore]>CALIBRAZIONE>CALIBRAZIONE. 4. Selezionare l'opzione per il segnale di output durante la calibrazione: Opzione Descrizione Attivo Lo strumento invia il valore di output misurato corrente durante la procedura di calibrazione. Hold (Memorizza) Il valore di output del sensore viene tenuto al valore misurato corrente durante la procedura di calibrazione. Transfer (Trasmetti) Durante la calibrazione viene inviato un valore predefinito. Per modificare il valore predefinito, fare riferimento al manuale dell'utente del controller. 5. Sul controller appare: • "Lett. stabile?" • La misura corrente dell'ossigeno disciolto • La misura corrente della temperatura 6. Quando la misura è stabile, premere ENTER. Sul display apparirà una schermata di immissione. Nota: la misur in genere si stabilizza in 2-3 minuti. Italiano 41 Se il valore non si stabilizza, appare la segnalazione "Unable to Calibrate" (Impossibile eseguire la calibrazione) seguita da un messaggio di errore. Nella Tabella 4 sono riportati i messaggi di errore e le soluzioni dei problemi di calibrazione. Tabella 4 Messaggi di errore della calibrazione campione Messaggio Descrizione Risoluzione Cal non corret Offset alto L'offset calcolato è troppo alto. Ripetere la calibrazione. Cal non corret Offset basso L'offset calcolato è troppo basso. Ripetere la calibrazione. Cal non corret Instabile Ripetere la calibrazione. Il valore non si è stabilizzato durante il tempo di calibrazione massimo consentito. Uscita dalla procedura di calibrazione 1. Durante la calibrazione, premere il tasto BACK (INDIETRO). Sono mostrate tre opzioni: Opzione Descrizione Annul Interrompe la calibrazione. Una nuova calibrazione deve riprendere dall'inizio. Ritorno cal Torna alla calibrazione corrente. Uscita Esce temporaneamente dalla calibrazione. Mentre la taratura è in corso in background è possibile accedere ad altri menu. È possibile avviare la calibrazione per un secondo sensore (ove presente). Per tornare alla calibrazione, premere il tasto MENU e selezionare Sensor Setup (Impostazione sensore), [Selezionare il sensore]. 2. Selezionare una delle opzioni. Confermare. Ripristino delle impostazioni predefinite di calibrazione Le impostazioni di calibrazione possono essere ripristinate ai valori predefiniti. I valori di guadagno e offset vengono impostati rispettivamente su 1.0 e 0.0. 1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CALIBRAZIONE>REIMPOSTAZ CA. 2. Sul display apparirà un messaggio di conferma. Confermare per reimpostare la curva di calibrazione del sensore ai valori di fabbrica. Manutenzione PERICOLO Pericoli multipli. Gli interventi descritti in questa sezione del documento devono essere eseguiti solo da personale qualificato. PERICOLO Rischio di esplosione. Non collegare o scollegare alcun componente o circuito elettrico dall'apparecchiatura senza aver prima interrotto l'alimentazione oppure solo nel caso in cui l'area sia ritenuta non pericolosa. PERICOLO Rischio di esplosione. La sostituzione di componenti potrebbe ridurre l'idoneità per Class 1, Division 2. Non sostituire alcun componente senza aver prima interrotto l'alimentazione e solo nel caso in cui l’area sia ritenuta non pericolosa. AVVISO La versione certificata per aree pericolose di questo prodotto non è conforme ai requisiti della Direttiva 94/9/CE (Direttiva ATEX). 42 Italiano Schema per le operazioni di manutenzione Il programma di manutenzione indica gli intervalli minimi per gli interventi di manutenzione di routine. Eseguire le attività di manutenzione più frequentemente per applicazioni che causano sporcamento degli elettrodi. Nota: per eseguire gli interventi di manutenzione o pulizia non smontare la sonda. Intervento di manutenzione Frequenza minima consigliata Pulizia del sensore 90 giorni Verifica della presenza di danni al sensore 90 giorni Calibrazione del sensore Come specificato dagli enti di regolamentazione Pulizia del sensore Pulire la superficie esterna del sensore con un panno morbido bagnato. Nota: se per eseguire la pulizia è necessario rimuovere il cappuccio, non esporre la parte interna dello stesso alla luce diretta del sole per periodi prolungati. Impostazione o modifica dell'intervallo di pulizia Le condizioni della specifica applicazione possono imporre intervalli più brevi o più lunghi fra le pulizie manuali del sensore. L'intervallo predefinito di pulizia è di 0 giorni. Per modificare l'intervallo, eseguire questa procedura. 1. Scegliere MENU>SETUP SONDA>[Scelta sensore]>CONFIGURAZIONE>CLEANING INTERVAL (INTERVALLO DI PULIZIA). 2. Modificare il valore secondo necessità. Confermare la modifica. • Per disattivare l'intervallo di pulizia, impostare il valore su '0'. Sostituzione del cappuccio del sensore AVVERTENZA Potenziale pericolo di esplosione. Il cappuccio per l'impostazione del sensore non è classificato per l'uso in aree pericolose. I cappucci di ricambio e quelli da utilizzare per l'impostazione del sensore vengono forniti con le istruzioni di installazione. Per la sostituzione del cappuccio, vedere le istruzioni incluse. Dopo aver installato il nuovo cappuccio del sensore, accertarsi che il numero di lotto sul cappuccio del sensore sia lo stesso numero di lotto letto da Modbus. Il sensore utilizza le informazioni di calibrazione inviate dal cappuccio del sensore. Per ottenere prestazioni e accuratezza ottimali, sostituire il cappuccio del sensore: • Ogni due anni, o più spesso se necessario • Nel caso in cui durante un'ispezione di routine si riscontrino segni significativi di erosione Individuazione ed eliminazione dei guasti Menu di verifica e diagnostica Il menu di verifica e diagnostica mostra le informazioni correnti e storiche del sensore LDO. Per accedere al menu di verifica e diagnostica, scegliere MENU>SETUP SONDA>[Scelta sensore]>DIAG/TEST. Italiano 43 Fare riferimento a Tabella 5. Tabella 5 Menu Diag/Test Opzione Descrizione Info sonda Versione SW - Visualizza la versione installata del software Boot program (Programma di avvio) - Visualizza la versione installata del programma di avvio Vers. guida - Visualizza la versione installata del driver software Sensor cap lot code (Codice lotto del tappo sensore) Visualizza il lotto di produzione del cappuccio del sensore Numero serie Numero di serie del sensore Correzione gain Regolare il valore di guadagno della calibrazione. Intervallo: da 0.50 a 2.00 Corr offset Regolare il valore di offset della calibrazione (mg/l o ppm). Intervallo: da –3.00 a +3.00 Fase diagnosi Mostra la fase per le lunghezze d'onda rossa, blu e totale. Si aggiorna ogni secondo. Diagn estesa Mostra l'ampiezza per le lunghezze d'onda rossa e blu. Si aggiorna ogni secondo. Days remaining to clean (Giorni alla pulizia) Mostra il numero di giorni residui fino alla successiva pulizia manuale programmata. Sensor life (Durata sensore) Mostra il numero di giorni residui fino alla successiva sostituzione programmata del cappuccio del sensore.. Elenco errori Se si verifica un errore, il valore sulla schermata di misurazione lampeggia. Il comportamento dell'output dipende dalle impostazioni del controller. Per maggiori informazioni, fare riferimento al manuale del controller. Per visualizzare gli errori correnti del sensore, scegliere MENU>DIAGN. SONDA>[Scelta sensore]>LISTA ERRORI. Fare riferimento a Tabella 6. Tabella 6 Elenco degli errori del sensore LDO Errore Possibile causa Risoluzione Rosso esteso bass (Il valore è inferiore a 0.01) Il cappuccio del sensore è montato in modo errato o assente. Rimuovere il cappuccio del sensore e rimontarlo. o Il percorso del fascio luminoso è bloccato dal cappuccio del sensore. Esaminare l'interno del cappuccio e della lente del sensore. Il sensore non funziona correttamente. Verificare che il LED lampeggi. Rivolgersi al produttore. Blue esteso basso (Il valore è inferiore a 0.01) Elenco avvisi Quando l'icona di avviso lampeggia (sc100 ed sc200) o quando lo schermo diventa giallo (sc1000), viene visualizzato un messaggio nella parte inferiore della schermata di misurazione. Sui controller sc1000 la schermata diventa gialla per segnalare un avviso. Per visualizzare gli avvisi correnti del 44 Italiano sensore, scegliere MENU>DIAGN. SONDA>[Scelta sensore]>LISTA AVVISI. Fare riferimento a Tabella 7. Tabella 7 Elenco degli avvisi del sensore Avviso Definizione Risoluzione Err impost EE Memoria danneggiata. I valori sono stati impostati su quelli predefiniti. Rivolgersi al servizio di assistenza tecnica. Temp < 0 °C La temperatura del processo è inferiore a 0 °C (32 °F) Aumentare la temperatura del processo o non utilizzare fino a quando la temperatura non rientra nell'intervallo di specifica del sensore. Temp > 50 °C La temperatura del processo è superiore a 50 °C (120 °F) Ridurre la temperatura del processo o non utilizzare fino a quando la temperatura non rientra nell'intervallo di specifica del sensore. Rosso esteso bass Il valore scende sotto a 0.03 Fare riferimento a Elenco errori a pagina 44. Rosso esteso alto Il valore è superiore a 0.35 Rivolgersi al servizio di assistenza tecnica. Blue esteso basso Il valore è inferiore a 0.03 Fare riferimento a Elenco errori a pagina 44. Blue esteso alto Il valore è superiore a 0.35 Rivolgersi al servizio di assistenza tecnica. Sensor cap lot code missing (Codice lotto del tappo sensore mancante). Il codice del cappuccio del sensore è corrotto. Il codice è stato automaticamente ripristinato sui codici predefiniti di cappuccio e lotto. Completare la procedura di impostazione del cappuccio del sensore. Se non è disponibile un cappuccio per l'impostazione del sensore, rivolgersi al servizio di assistenza tecnica. Err EE RISERV Elenco degli eventi L'elenco degli eventi è un registro di tutte le modifiche apportate alla modalità in cui il sensore registra i dati. Per visualizzare gli eventi del sensore, scegliere MENU>DIAGN. SONDA>[Scelta sensore]>EVENT LIST (ELENCO EVENTI). Fare riferimento a Tabella 8. Tabella 8 Elenco degli eventi del sensore Evento Descrizione Altitude/Pressure unit change (Modifica unità alt/aria) Le unità della pressione atmosferica o dell'altitudine sono state modificate. Altitude/Pressure change (Modifica alt/press) Il valore dell'altitudine o della pressione atmosferica è stato modificato. Temperature change (Modifica temperatura) Le unità della temperatura sono state modificate. Unit change (Modifica unità) È stata modificata un'unità di misura. Salinity change (Modifica salinità) Il valore di salinità è stato modificato. Ripr config Le impostazioni del sensore sono state ripristinate ai valori predefiniti. Sensor setup change (Modifica setup sonda) L'impostazione del sensore è stata modificata. Cleaning interval change (Modifica intervallo di pulizia) L'intervallo di tempo per la pulizia del sensore è stato modificato. Sensor life change (Modifica durata sensore) L'intervallo di tempo per la sostituzione del cappuccio del sensore è stato modificato. Italiano 45 Bediening Configureer de sensor Gebruik het instellingen om identificerende informatie voor de sensor in te voeren en opties voor het omgaan met gegevens en opslag te wijzigen. Raadpleeg de gebruikshandleiding voor informatie over de installatie van de sensor. Zorg ervoor dat alle waarden in het instellingenmenu juist zijn voor de applicatie. 1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>SETTINGS (INSTELLINGEN). 2. Selecteer een optie, ENTER. Een lijst met beschikbare opties wordt weergegeven in onderstaande tabel. Optie Omschrijving Naam Wijzigt de naam die overeenkomt met de sensor bovenaan op het meetscherm. De naam is beperkt tot 10 karakters en mag bestaan uit een willekeurige combinatie van letter, cijfers, spaties en interpunctietekens. Eenheid Temperatuur–Stelt de temperatuureenheid in op °C (standaard) of °F. Meting–Stelt de meeteenheden in op mg/L, ppm of %. Hoogte/Druk–Stelt de hoogte in op m of ft of stelt de atmosferische drukeenheden in op mmHg of torr. (Standaardwaarde = 0 ft) Hoogte/druk Voer de waarde van de hoogte of atmosferische druk in. Deze waarde moet nauwkeurig zijn om metingen van het verzadigingspercentage en kalibratie in lucht te voltooien. (Standaard = 0 ft). Zoutgehalte Voer de waarde van het zoutgehalte in. Zoutgehalte: 0,00 tot 250,00 delen per duizend (‰). (Standaardwaarde = 0) Signaalgemiddelde Stelt het tijdsinterval in op gemiddelde signalen in seconden Reinigingsinterval Stelt het tijdsinterval in voor handmatige sensorreiniging in dagen (Standaardwaarde = 0 dagen. Een waarde van 0 dagen schakelt het reinigingsinterval uit.) Reinigingsinterval resetten Stelt het tijdsinterval in op het laatst bewaarde reinigingsinterval Interval datalogger Stelt het tijdsinterval voor gegevensopslag in de datalogger in—0,5, 1, 2, 5, 10, 15 (standaard), 30, 60 minuten. Resetten Herstelt de configureerbare standaardwaarden voor de sensor. Wijzigt de instelling voor helling of offset niet. Voer de waarde van de atmosferische druk in De fabrieksinstelling voor atmosferische (lucht)druk is 0 ft of zeeniveau. Om de standaardwaarde te wijzigen, gebruikt u de stappen in deze procedure. De afstelling voor luchtdruk wordt ingevoerd als hoogte- of drukeenheden (gewenst). Opmerking: Nauwkeurige luchtdruk is belangrijk voor verzadigde luchtkalibratie. Gebruik alleen absolute druk, geen aangepaste. Als de absolute luchtdruk onbekend is, gebruikt u de correcte hoogte voor de locatie. 1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>SETTINGS (INSTELLINGEN)>UNIT (EENHEID)>AIR PRESSURE/ALTITUDE (LUCHTDRUK/HOOGTE). 2. Selecteer één van de genoemde opties: Optie Omschrijving Hoogte ft Feet (voet)—meeteenheid voor hoogte 46 Nederlands Optie Omschrijving Hoogte m Meters—metrische eenheid voor hoogtemeting Luchtdruk mmHg Millimeter kwikdruk—metrische eenheid voor meting van absolute luchtdruk Luchtdruk torr Meeteenheid voor absolute luchtdruk 3. Bevestig de selectie. Het invoerscherm voor de waarden geeft de geselecteerde units weer. 4. Voer de waarde in en bevestig. Correctiewaarde van zoutgehalte invoeren Metingen van opgelost zuurstof in zoutmonsters kunnen een zichtbare DO-waarde aantonen die erg verschilt van de werkelijke DO-waarde. Om de invloed van opgeloste zouten in een monster te corrigeren, voert u een correctiefactor voor het zoutgehalte in. Opmerking: Als de aanwezigheid of hoeveelheid van het zoutgehalte in het proces onbekend is, raadpleegt u het technisch personeel voor behandelingsfaciliteiten. 1. Gebruik een geleidbaarheidsmeter om de geleidbaarheid van het monster te meten in mS/cm bij een referentietemperatuur van 20 °C (68 °F). 2. Gebruik Tabel 1 om de correctiefactor van het zoutgehalte in delen per duizend van (‰) verzadiging te schatten. Opmerking: De chloride-ionconcentratie in g/kg is gelijk aan het chloorgehalte van het monster. Zoutgehalte wordt berekend met de formule: Zoutgehalte = 1,80655 × chloorgehalte. Zoutgehalte kan worden berekend met de relatie in sectie 2520 B van Standard Methods for the Examination of Water and Wastewater.1, 3. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>SETTINGS (INSTELLINGEN)>SALINITY (ZOUTGEHALTE). 4. Voer de correctiefactor van het zoutgehalte in en bevestig. Tabel 1 Verzadiging van zoutgehalte (‰) per geleidbaarheidswaarde (ms/cm) 1 mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Standard Methods for the Examiniation of Water and Wastewater, 20e editie. Editors Lenore S. Clesceri, Arnold E. Greenberg en Andrew D. Eaton, p. 2-48-2-29 (1998). De relatie tussen chloorgehalte en de oplosbaarheid van zuurstof wordt gegeven in dezelfde referentie in 4500-O:I p. 4-131. Nederlands 47 Kalibratie voor metingen De sensor is gekalibreerd volgens specificatie in de fabriek. De fabrikant raadt kalibratie af, tenzij regelmatig vereist door officiële instanties. Als kalibratie is vereist, laat u de sensor in evenwicht komen met het proces vóór kalibratie. Kalibreer de sensor niet tijdens het instellen. Tabel 2 toont opties voor kalibratie. Tabel 2 Kalibratie-opties Optie Omschrijving Kalibratie lucht Aanbevolen kalibratiemethode. Deze kalibratie wijzigt de helling. Kalibratie Kalibratie volgens vergelijking met een handheld DO-meter. Deze kalibratie wijzigt de offset. Kalibratie resetten Stelt de kalibratiewaarde voor de steilheid (helling) en offset terug naar de fabrieksinstellingen: standaardwaarde=1,0; standaardoffset=0,0 Kalibratie lucht Gebruikersopmerkingen: • • • • • Zorg ervoor dat er zich water in de kalibratietas bevindt. Zorg ervoor dat de afdichting tussen de kalibratietas en de behuizing van de sensor goed afdicht. Zorg ervoor dat de sensor droog is tijdens kalibratie. Zorg ervoor dat de luchtdruk-/hoogte-instelling nauwkeurig is voor de kalibratielocatie. Laat de sensortemperatuur voldoende stabiliseren tot de omgevingstemperatuur van de kalibratietas. Bij een groot temperatuurverschil tussen het proces en de kalibratielocatie kan het stabiliseren 15 minuten duren. 1. Verwijder de sensor uit het proces. Reinig de sensor met een natte doek. 2. Plaats de gehele sensor in een kalibratietas met 25-50 ml water. Zorg ervoor dat de sensorkap niet in contact komt met het water in de kalibratietas en dat er zich geen druppels op de sensorkap bevinden. 3. Gebruik een rubberen ring, binder of hand om een afdichting om de behuizing van de sensor te creëren. 4. Laat het instrument 15 minuten stabiliseren vóór de kalibratie. Voorkom tijdens stabilisatie direct zonlicht op de kalibratietas. 5. Zorg ervoor dat de huidige absolute luchtdruk of hoogte juist is geconfigureerd. Opmerking: De fabrikant beveelt het gebruik van absolute of werkelijke luchtdruk aan als beste praktijkmethode. 6. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>CALIBRATION (KALIBRATIE)>AIR CALIBRATION (LUCHTKALIBRATIE). 7. Selecteer de optie voor het uitgangssignaal tijdens de kalibratie: Optie Omschrijving Actief Het instrument verzendt de actuele uitgangsmeetwaarde tijdens de kalibratieprocedure. Hold De sensoruitgangswaarde wordt vastgezet op de actuele meetwaarde tijdens de kalibratieprocedure. Overzenden Tijdens de kalibratie wordt een vooraf ingestelde waarde verzonden. Raadpleeg de gebruikershandleiding van de controller om de vooraf ingestelde waarde te wijzigen. 8. De controller toont de melding "Plaats de hele sensor in de tas met water.". Wacht totdat de waarde stabiel is. Druk op ENTER om de stabiele waarde te accepteren. Laat in plaats daarvan de kalibratie doorgaan totdat op het display de volgende melding wordt weergegeven: "Taak is voltooid. ". 9. Als de sensor is gekalibreerd, plaatst u de sensor in het proces. Druk op ENTER. 48 Nederlands Afbeelding 1 Luchtkalibratieprocedure Als de waarde niet stabiliseert, wordt op het display "Unable to Calibrate" ("Kalibratie onmogelijk") weergegeven, gevolgd door een foutmelding. Tabel 3 toont de foutmelding en de oplossing voor kalibratieproblemen. Tabel 3 Foutmeldingen van luchtkalibratie Bericht Omschrijving Oplossing Kalibratie mislukt! Versterkingscorrectie is te hoog. De berekende steilheidswaarde is te hoog. Herhaal de kalibratie. Kalibratie mislukt! Versterkingscorrectie is te laag. De berekende steilheidswaarde is te laag. Herhaal de kalibratie. Kalibratie mislukt! Instabiel De waarde is niet gestabiliseerd binnen de maximaal toegestane kalibratietijd. Herhaal de kalibratie. Kalibratie via vergelijking Bij deze kalibratiemethode wordt gebruik gemaakt van een alternatieve sensor die aan een handheldmeter is bevestigd. 1. Plaats de alternatieve processor in het proces. Plaats de tweede sensor zo dicht mogelijk bij de eerste sensor. 2. Wacht totdat de DO-waarde stabiel is. 3. Op de controller van de eerste sensor gaat u naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>CALIBRATION (KALIBRATIE)>CALIBRATION (KALIBRATIE). 4. Selecteer de optie voor het uitgangssignaal tijdens de kalibratie: Optie Omschrijving Actief Het instrument verzendt de actuele uitgangsmeetwaarde tijdens de kalibratieprocedure. Hold De sensoruitgangswaarde wordt vastgezet op de actuele meetwaarde tijdens de kalibratieprocedure. Overzenden Tijdens de kalibratie wordt een vooraf ingestelde waarde verzonden. Raadpleeg de gebruikershandleiding van de controller om de vooraf ingestelde waarde te wijzigen. 5. De controller toont: • "Is de meetwaarde stabiel?" • Meting van de huidige opgeloste zuurstof Nederlands 49 • De huidige temperatuurmeting 6. Als de meting stabiel is, drukt u op ENTER. Op het display wordt een invoerscherm weergegeven. Opmerking: De meting is doorgaans na 2 tot 3 minuten stabiel. Als de waarde niet stabiliseert, wordt op het display "Unable to Calibrate" ("Kalibratie onmogelijk") weergegeven, gevolgd door een foutmelding. Tabel 4 toont de foutmelding en de oplossing voor kalibratieproblemen. Tabel 4 Foutmeldingen van monsterkalibratie Bericht Omschrijving Oplossing Kalibratie mislukt! Offset is te hoog. De berekende offsetwaarde is te hoog. Herhaal de kalibratie. Kalibratie mislukt! Offset is te laag. De berekende offsetwaarde is te laag. Herhaal de kalibratie. Kalibratie mislukt! Instabiel De waarde is niet gestabiliseerd binnen de maximaal toegestane kalibratietijd. Herhaal de kalibratie. Kalibratieprocedure sluiten 1. Tijdens de kalibratie drukt u op de toets TERUG. Er worden drie mogelijkheden getoond: Optie Omschrijving Annuleren Stop de kalibratie. Een nieuwe kalibratie moet vanaf het begin starten. Keer terug naar kalibratie Keer terug naar de huidige kalibratie. Terug Verlaat de kalibratie tijdelijk. Toegang naar andere menu's is toegestaan terwijl de kalibratie op de achtergrond wordt voortgezet. Een kalibratie voor een tweede sensor (indien aanwezig) kan worden gestart. Druk op de toets MENU om naar de kalibratie terug te keren en selecteer Sensor Setup, [Select Sensor]. 2. Selecteer één van de opties. Bevestig. Kalibratiestandaarden resetten Kalibratie-instellingen kunnen worden teruggezet naar de fabrieksinstellingen. Steilheids- en offsetwaarden worden respectievelijk ingesteld op 1,0 en 0,0. 1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>CALIBRATION (KALIBRATIE)>RESET CALIBRATION (KALIBRATIE RESETTEN). 2. Op het display wordt een bevestigingsbericht weergegeven. Bevestig om de sensor te resetten naar de kalibratiecurve van de standaardfabrieksinstellingen. Onderhoud GEVAAR Diverse gevaren. Alleen bevoegd personeel mag de in dit deel van het document beschreven taken uitvoeren. GEVAAR Explosiegevaar. Koppel elektrische componenten of circuits van het apparaat alleen aan of los als de stroom uitgeschakeld is of als de zone ongevaarlijk is. 50 Nederlands GEVAAR Explosiegevaar. Vervanging van componenten kan ertoe leiden dat het apparaat niet meer geschikt is voor gebruik in omgevingen van klasse 1, divisie 2. Vervang componenten alleen als de stroom uitgeschakeld is of als de zone ongevaarlijk is. LET OP Deze productversie die gecertificeerd is voor gevaarlijke omgevingen voldoet niet aan de vereisten van de 94/9/EG-Richtlijn (ATEX-richtlijn). Onderhoudsschema Het onderhoudsschema toont minimale intervallen voor regelmatige onderhoudstaken. Voer onderhoudstaken vaker uit voor toepassingen waarbij de elektroden worden vervuild. Opmerking: Demonteer de sensor niet voor onderhoud of reiniging. Onderhoudswerk Minimale aanbevolen frequentie De sensor reinigen 90 dagen Controleer de sensor op schade 90 dagen De sensor kalibreren Zoals aanbevolen door officiële instanties De sensor reinigen Reinig de buitenkant van de sensor met een zachte, vochtige doek. Opmerking: Als de sensorkap moet worden verwijderd voor reiniging, voorkom dan langdurig direct zonlicht op de binnenkant van de kap. Stel het reinigingsinterval in of wijzig deze Bij sommige toepassingen is mogelijk een kortere of langere tijdsduur nodig tussen handmatige sensorreinigingen. Het standaardreinigingsinterval is 0 dagen. Om het interval te wijzigen, raadpleegt u de stappen van deze procedure. 1. Ga naar MENU>SENSOR SETUP (SENSORINSTELLING)>[Select Sensor (Selecteer sensor)]>SETTINGS (INSTELLINGEN)>CLEANING INTERVAL (REINIGINGSINTERVAL). 2. Wijzig indien nodig de weergegeven waarde. Bevestig de wijziging. • Om het reinigingsinterval uit te schakelen, stelt u de waarde in op '0'. Sensorkap vervangen WAARSCHUWING Mogelijk explosiegevaar. De instelkap van de sensor is niet geschikt voor gebruik in gevaarlijke omgevingen. Vervangende sensorkappen en instelkappen worden met de installatie-instructies meegeleverd. Raadpleeg de bijgeleverde instructies om de kap te vervangen. Nadat de nieuwe sensorkap is geplaatst, dient u te controleren of het batchnummer op de sensorkap overeenkomt met het batchnummer dat wordt uitgelezen door Modbus. De sensor gebruikt de kalibratie-informatie uit de sensorkap. Voor de beste resultaten en nauwkeurigheid, vervangt u de sensorkap: • Elke twee jaarof vaker indien nodig • Als routine-inspectie aanzienlijke slijtage van de sensorkap aantoont Nederlands 51 Problemen oplossen Diagnose- en testmenu Het menu om te testen en voor diagnostiek toont de huidige en historische informatie over de LDOsensor. Voor toegang tot het diagnose- en testmenu gaat u naar MENU>SENSOR SETUP (SENSORINSTELLING>[Selecteer sensor]>MAINTENANCE (ONDERHOUD). Raadpleeg Tabel 5. Tabel 5 Menu onderhoud Optie Omschrijving Sensorinformatie Softwareversie—Toont de geïnstalleerde softwareversie Bootprogramma— Toont de geïnstalleerde bootversie Versie stuurprogramma—Toont het geïnstalleerde stuurprogramma van de software Partij-ID sensorkap Toont de partijcode van de sensorkap Serienummer Serienummer van sensor Versterkingscorrectie Past de kalibratiewaarde voor steilheid aan. Bereik: 0,50 tot 2,00 Offset-correctie Past de offsetwaarde van de kalibratie aan (mg/l of ppm). Bereik: –3,00 tot +3,00 Fase-diagnostiek Toont de fase voor totale, rode en blauwe golflengten. Wordt één keer per seconde bijgewerkt. Amplitude-diagnostiek Toont de amplitude voor totale, rode en blauwe golflengten. Wordt één keer per seconde bijgewerkt. Resterende dagen voor reiniging Toont het aantal dagen tot de volgende geplande handmatige reiniging. Levensduur sensor Toont het aantal dagen tot de volgende geplande vervanging van de sensorkap. Foutenlijst Als een fout optreedt, knippert de meetwaarde op het meetscherm. Het uitgangsgedrag wordt bepaald door controllerinstellingen. Raadpleeg de controllerhandleiding voor details. Om de huidige sensorfouten weer te geven, gaat u naar MENU>SENSOR DIAGNOSTICS (SENSORDIAGNOSE)>[Select Sensor (Selecteer sensor)]>ERROR LIST (FOUTENLIJST). Raadpleeg Tabel 6. Tabel 6 Foutenlijst voor de LDO-sensor Foutmelding Mogelijke oorzaak Oplossing Rode amplitude is te laag. (Waarde is minder dan 0.01) Verwijder de sensorkap en breng deze op nieuw aan. of De sensorkap is niet aangebracht of onjuist aangebracht. Blauwe amplitude is te laag. (Waarde is minder dan 0.01) Het lichtpad wordt in de sensorkap geblokkeerd. Controleer de binnenzijde van de sensorkap en lens. De sensor functioneert niet goed. Zorg ervoor dat de LED knippert. Neem contact op met de fabrikant. 52 Nederlands Waarschuwingslijst Als het waarschuwingssymbool knippert (sc100 en sc200) of als het scherm geel wordt (sc1000), verschijnt er een bericht onder in het meetscherm. Op de sc1000 wordt het scherm geel om een waarschuwing aan te geven. Om de huidige sensorwaarschuwingen weer te geven, gaat u naar MENU> SENSOR DIAGNOSTICS (SENSORDIAGNOSE)>[Select Sensor (Selecteer sensor)]>WARNING LIST (WAARSCHUWINGSLIJST). Raadpleeg Tabel 7. Tabel 7 Sensorwaarschuwingslijst Waarschuwing Definitie Oplossing Fout EEPROMinstellingen Opslag is corrupt. De waarden zijn teruggezet naar de fabrieksinstellingen. Neem contact op met de technische ondersteuningsafdeling. Temperatuur < 0 °C De procestemperatuur is onder 0 °C (32 °F) Verhoog de procestemperatuur of stop het gebruik totdat de procestemperatuur binnen het gespecificeerde bereik van de sensor ligt. Temperatuur > 50 °C De procestemperatuur is boven 50 °C (120 °F) Verlaag de procestemperatuur of stop het gebruik totdat de procestemperatuur binnen het gespecificeerde bereik van de sensor ligt. Rode amplitude is te laag. Waarde valt onder 0,03 Raadpleeg Foutenlijst op pagina 52 . Rode amplitude is te hoog. Waarde is groter dan 0,35 Bel de technische ondersteuning. Blauwe amplitude is te laag. Waarde is minder dan 0,03 Raadpleeg Foutenlijst op pagina 52. Blauwe amplitude is te hoog. Waarde is groter dan 0,35 Bel de technische ondersteuning. Batch-ID sensorkap ontbreekt. De code van de sensorkap is corrupt. De code is automatisch teruggezet op de standaardcodes van de kap en partij. Voltooi de instelprocedure van de sensorkap. Als er geen instelkap voor de sensorkap beschikbaar is, neemt u contact op met de technische ondersteuning. EEPROM-fout Eventlijst De eventlijst houdt een wijzigingenlogboek bij over hoe gegevens door de sensor worden opgeslagen. Om sensorgebeurtenissen weer te geven, gaat u naar MENU>SENSOR DIAGNOSTICS (SENSORDIAGNOSE)>[Select Sensor (selecteer sensor)]>EVENT LIST (EVENTLIJST). Raadpleeg Tabel 8. Tabel 8 Eventlijst voor de sensor Event Omschrijving Wijziging hoogte/drukeenheid Eenheden van atmosferische druk of hoogte zijn gewijzigd. Wijziging hoogte/druk De waarde voor hoogte of atmosferische druk is gewijzigd. Wijziging temperatuur De temperatuureenheden zijn gewijzigd. Wijziging eenheid Een nieuwe meeteenheid is gewijzigd. Wijziging zoutgehalte De waarde voor het zoutgehalte is gewijzigd. Resetten Sensorinstellingen zijn op fabrieksstandaarden ingesteld. Wijziging sensorinstellingen De instellingen van de sensor zijn gewijzigd. Nederlands 53 Tabel 8 Eventlijst voor de sensor (vervolg) Event Omschrijving Wijziging reinigingsinterval Het tijdsinterval voor sensorreinigingen is gewijzigd. Wijziging levensduur sensor Het tijdsinterval voor vervanging van de sensorkap is gewijzigd. 54 Nederlands Betjening Konfiguration af sensoren Brug menuen Indstillinger til at indtaste identifikationsoplysninger til sensoren og for at skifte funktioner til datahåndtering og opbevaring. Der er flere oplysninger om installation af sensor i brugervejledningen. Kontroller, at alle værdier i menuen Indstillinger er korrekte til formålet. 1. Gå MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER. 2. Vælg en funktion, og tryk på ENTER. Listen over tilgængelige funktioner vises i tabellen nedenfor. Indstilling Beskrivelse Navn Ændrer det navn, der korresponderer med sensoren øverst på måleskærmbilledet. Navnet er begrænset til 10 tegn i en vilkårlig kombination af bogstaver, tal, mellemrum eller tegnsætning. Enhed Temperatur - Indstiller temperaturenhederne til °C (standard) eller °F. Mål - Indstiller måleenhederne til mg/L, ppm eller %. Højde/tryk - Indstiller højden til m eller ft eller indstiller den atmosfæriske trykenhed til mmHg eller torr. (Standardværdi = 0 ft) Højde/tryk Indtast værdien for højden eller det atmosfæriske tryk. Denne værdi skal være præcis for at fuldføre procentvise mætningsmålinger og kalibrering i luft. (Standard = 0 ft). Salinitet Indstiller værdien for salinitetindhold. Salinitetsinterval: 0,00 til 250,00 dele pr. tusinde (‰). (Standardværdi = 0) Signalgennemsnit Indstil tidsintervallet til gennemsnittet for signaler i sekunder. Rengøringsinterval Indstil tidsintervallet for manuel rengøring af sensoren i dage (standardværdi = 0 dage). En værdi på 0 dage deaktiverer rengøringsintervallet. Nulstil rengøringsinterval Indstil tidsintervallet til seneste gemte rengøringsinterval. Log interval Indstiller tidsintervallet for datalagring i dataloggen - 0.5, 1, 2, 5, 10, 15 (standard), 30, 60 minutter. Reset (Nulstil) Gendanner de standardværdier for sensoren, som kan konfigureres Undgå at ændre indstillingen for hældning eller forskydning. Angivelse af værdien for det atmosfæriske tryk Standardindstillingen for det atmosfæriske (luft)tryk er 0 ft eller havoverfladen. Hvis du vil ændre standardværdien, skal du følge denne fremgangsmåde. Justeringen af lufttrykket angives som stigning eller trykenheder (foretrukket). BEMÆRK: Et præcist lufttryk er afgørende for kalibrering af mættet luft . Anvend kun det absolutte tryk, ikke det justerede. Hvis det absolutte lufttryk ikke er kendt, skal du bruge den rette stigning for placeringen. 1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>ENHED>LUFTTRYK/HØJDE. 2. Vælg en af de anførte enhedsindstillinger: Indstilling Beskrivelse Højde i fod Fod - måleenhed for stigning Højde i meter Meter - metrisk måleenhed for stigning Lufttryk mmHg Milimeter kviksølv - metrisk måleenhed for absolut lufttryk Lufttryk torr Måleenhed for absolut lufttryk Dansk 55 3. Bekræft valget. Indtastningsskærmbilledet viser de valgte enheder. 4. Indtast værdien , og bekræft. Angivelse af en korrektionsværdi for salinitetindhold Målinger af opløst ilt i salinitetprøver kan vise en umiddelbar værdi, der afviger meget fra den faktiske værdi. Hvis du vil rette påvirkningen af de opløste salte i prøven, skal du angive en korrektionsfaktor for salinitetindholdet. BEMÆRK: Hvis forekomsten eller mængden af salinitet i processen er ukendt, skal du henvende dig hos behandlingsstedets teknikere. 1. Anvend en ledningsevnemåler til at måle ledningsevnen for prøven i mS/cm ved en referencetemperatur på 20 °C (68 °F). 2. Brug Tabel 1 til at estimere korrektionsfaktoren for salinitetindholdet som mætning i dele pr. tusinde (‰). BEMÆRK: Kloridionkoncentrationen i g/kg svarer til kloriniteten i prøven. Salinitetindholdet beregnes med formularen: Salinitet = 1,80655 x klorinitet. Saliniteten kan beregnes med forholdet i afsnit 2520 B i standardmetoder for undersøgelse af vand og spildvand .1, 3. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>SALINITET. 4. Angiv korrektionsfaktoren for salinitetindholdet og bekræft. Tabel 1 Salinitetsmætning (‰) pr. ledningsevneværdi (mS/cm) mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Kalibrering til målinger Sensoren er kalibreret af fabrikken. Producenten anbefaler ikke kalibrering med mindre det kræves af myndighederne. Hvis kalibreringen er påkrævet, skal du lade sensoren blive nulstillet i processen, før kalibreringen udføres. Undgå at kalibrere sensoren under opsætning. Tabel 2 viser indstillinger for kalibreringen. 1 Standardmetoder for undersøgelse af vand og spildvand , 20. udgave. Redaktører: Lenore S. Clesceri, Arnold E. Greenberg og Andrew D. Eaton, s. 2-48-2-29 (1998). Forholdet mellem klorinitet og iltsolubititet er angivet i samme reference i 4500-O:I s. 4-131. 56 Dansk Tabel 2 Kalibreringsindstillinger Indstilling Beskrivelse Luftkalibrering Anbefalet kalibreringsmetode. Denne kalibrering ændrer hældningen. Kalibrering Kalibrering ved sammenligning med en håndholdt iltmåler. Denne kalibrering ændrer forskydningen. Nulstil kalibrering Nulstiller kalibreringens stigning (hældning) og forskydning til standardindstillingen: standardstigning = 1,0 og standardforskydning = 0,0. Luftkalibrering Brugerbemærkninger • • • • • Kontroller, at kalibreringstasken indeholder vand. Kontroller, at forseglingen mellem kalibreringstasken og sensorenheden er tæt. Kontroller, at sensoren er tør, når den kalibreres. Kontroller, at indstillingen for lufttryk/stigning er præcis for kalibreringsplaceringen. Giv tilstrækkelig tid til, at sensortemperaturen kan stabilisere sig til temperaturen for kalibreringstaskens placering. Er der stor temperaturforskel mellem processen og kalibreringsplaceringen, kan temperaturstabilliseringen tage op til 15 minutter. 1. Fjern sensoren fra processen. Brug en våd klud til at rense sensoren. 2. Placer hele sensoren i en kalibreringstaske med 25 - 50 ml vand. Kontroller, at sensorhætten ikke berører vandet inde i kalibreringstasken, og at der ingen vanddråber findes på sensorhætten. 3. Brug en elastik, et bånd eller hånden til at skabe en tæt forsegling omkring sensorenheden. 4. Lad instrumentet stabilisere i 15 minutter, før kalibreringen udføres. Hold kalibreringstasken væk fra direkte sollys under stabiliseringsprocessen. 5. Kontroller, at det aktuelle absolutte lufttryk eller -stigning er konfigureret korrekt. BEMÆRK: Producenten anbefaler at anvende absolut eller faktisk lufttryk som bedste praksis. 6. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>LUFTKALIBRERING. 7. Vælg indstillingen for udgangssignal under kalibrering: Indstilling Beskrivelse Aktiv Instrumentet sender den aktuelt målte udgangsværdi under kalibreringsprocessen. Hold Sensorens udgangsværdi fastholdes på den aktuelt målte værdi i løbet af kalibreringsprocessen. Overfør En forudindstillet værdi sendes under kalibreringen. Se brugerhåndbogen til kontrolenheden for at ændre den forudindstillede værdi. 8. Kontrolenheden viser "Put the entire sensor in the bag with water.” (Læg hele sensoren i tasken med vand). Lad værdien stabilisere sig. Tryk på ENTER for at acceptere den stabile værdi. Alternativt kan kalibreringen fortsætte, indtil displayet viser "Task was succesfully completed. " 9. Når sensoren er kalibreret, skal du føje den til processen. Tryk på ENTER. Dansk 57 Figur 1 Luftkalibreringsprocedure Hvis værdien ikke stabiliserer sig, viser displayet "Unable to Calibrate" (Kan ikke kalibrere), efterfulgt af en fejlmeddelelse. Tabel 3 viser fejlmeddelelsen og løsninger på kalibreringsproblemerne. Tabel 3 Fejlmeddelelse for luftkalibrering Meddelelse Beskrivelse Opløsning Kalibrering mislykkedes! Forstærkningskorrektion er for høj. Den beregnede stigningsværdi er for høj. Gentag kalibreringen. Kalibrering mislykkedes! Forstærkningskorrektion er for lav. Den beregnede stigningsværdi er for lav. Gentag kalibreringen. Kalibrering mislykkedes! Ustabil Værdien stabiliserede sig ikke inden for den maksimalt tilladte kalibreringstid. Gentag kalibreringen. Kalibrering ved hjælp af sammenligning Denne kalibreringsmetode anvender en alternativ sensor, der er tilsluttet en håndholdt måler. 1. Placer den alternative sensor i processen. Placer den anden sensor så tæt som muligt på den første sensor. 2. Vent, indtil opløst ilt måleværdien har stabiliseret sig. 3. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>KALIBRERING på kontrolenheden for den første sensor. 4. Vælg indstillingen for udgangssignal under kalibrering: Indstilling Beskrivelse Aktiv Instrumentet sender den aktuelt målte udgangsværdi under kalibreringsprocessen. Hold Sensorens udgangsværdi fastholdes på den aktuelt målte værdi i løbet af kalibreringsprocessen. Overfør En forudindstillet værdi sendes under kalibreringen. Se brugerhåndbogen til kontrolenheden for at ændre den forudindstillede værdi. 5. Kontrolenheden viser: • ”Er aflæsningen stabil?” • Den aktuelle måling af opløst ilt • Den aktuelle temperaturmåling 6. Når målingen er stabil, skal du trykke på ENTER. Displayet viser et indtastningsskærmbillede. BEMÆRK: Målingen vil normalt stabilisere sig i løbet af 2 - 3 minutter. 58 Dansk Hvis værdien ikke stabiliserer sig, viser displayet "Unable to Calibrate" (Kan ikke kalibrere), efterfulgt af en fejlmeddelelse. Tabel 4 viser fejlmeddelelsen og løsninger på kalibreringsproblemerne. Tabel 4 Fejlmeddelelser for prøvekalibrering Meddelelse Beskrivelse Opløsning Kalibrering mislykkedes! Forskydning er for høj. Den beregnede stigningsværdi er for høj. Gentag kalibreringen. Kalibrering mislykkedes! Forskydning er for lav. Den beregnede stigningsværdi er for lav. Gentag kalibreringen. Kalibrering mislykkedes! Ustabil Værdien stabiliserede sig ikke inden for den maksimalt tilladte kalibreringstid. Gentag kalibreringen. Afslutning af kalibreringsprocessen 1. Tryk på tasten BACK (TILBAGE) under kalibreringen, Der vises tre funktioner: Indstilling Beskrivelse afbryde Stop kalibreringen. En ny kalibrering skal starte forfra. Vend tilbage til kalibrering Vend tilbage til den aktuelle kalibrering. Afslut Afslut kalibreringen midlertidigt. Adgang til andre menuer er tilladt, mens kalibreringen fortsætter i baggrunden. Der kan startes en kalibrering for en anden sensor (hvis forhåndenværende). Tryk på tasten MENU og vælg Sensor Setup (Sensoropsætning), [Vælg sensor] for at vende tilbage til kalibreringen. 2. Vælg en af indstillingerne. Bekræft. Nulstilling til kalibreringens standardindstillinger Kalibreringsindstillingerne kan nulstilles til standardindstillingerne. Stignings- og forskydningsværdier bliver indstillet henholdsvis til 1,0 og 0,0. 1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>KALIBRERING>NULSTIL KALIBRERING. 2. Displayet viser en bekræftelse. Kontroller, at sensoren er nulstillet til standardkurven for kalibrering. Vedligeholdelse FARE Flere farer. Kun kvalificeret personale må udføre de opgaver, som er beskrevet i dette afsnit i dokumentet. FARE Eksplosionsfare. Undlad at tilkoble eller frakoble elektriske komponenter eller kredsløb på udstyret, medmindre der er slukket for strømmen, eller området vides at være ufarligt. FARE Eksplosionsfare. Udskiftning af komponenter kan påvirke egnetheden til klasse 1, sektion 2. Undlad at udskifte komponenter, medmindre der er slukket for strømmen, og området vides at være ufarligt. Dansk 59 BEMÆRKNING Den version af dette produkt, som er klassificeret til farlige placeringer, opfylder ikke kravene ifølge 94/9/EUdirektivet (ATEX-direktivet). Vedligeholdelsesplan Vedligeholdelsesplanen viser minimumintervallerne for de regelmæssige vedligeholdelsesopgaver. Udfør vedligeholdelsesopgaverne hyppigere for programmer, der forårsager elektrodetilsmudsning. BEMÆRK: Undgå at skille sensoren ad i forbindelse med vedligeholdelse eller rengøring. Vedligeholdelsesopgave Anbefalet minimal hyppighed Rengøring af sensoren 90 dage Kontrol af sensoren for beskadigelse 90 dage Kalibrering af sensoren Som anbefalet ifølge myndighederne Rengøring af sensoren Rens sensorens yderside med en blød, våd klud. BEMÆRK: Hvis sensorhætten skal fjernes af hensyn til rengøringen, skal du undgå at udsætte hættens inderside for direkte sollys i længere tid. Indstilling eller ændring af rengøringsintervallet Afhængigt af betingelserne for anvendelsen kan der være behov for kortere eller længere tid mellem de manuelle sensorrengøringer. Standardintervallet for rengøring er 0 dage. Hvis du vil ændre intervallet, skal du benytte fremgangsmåden her. 1. Gå til MENU>SENSOR SETUP>[Vælg sensor]>INDSTILLINGER>RENGØRINGSINTERVAL. 2. Tilpas den viste værdi efter behov. Bekræft ændringen. • Hvis du vil deaktivere rengøringsintervallet, skal du indstille værdien til '0'. Udskiftning af sensorhætten ADVARSEL Potentiel eksplosionsfare Sensorhætten i startopsætningen er ikke klassificeret til brug på farlige placeringer. Reservesensorhætterne og hætterne i startopsætningen leveres med installationsanvisninger. Se de medfølgende anvisninger i udskiftning af hætten. Når den nye sensorhætte er installeret, skal du kontrollere at lot nummeret på sensorhætten svarer til det lot nummer, der læses af Modbus. Sensoren anvender kalibreringsoplysninger fra sensorhætten. Udskift sensorhætten for at opnå optimal ydeevne og præcision: • Hvert 2. åreller oftere, hvis det er nødvendigt • Når det regelmæssige eftersyn viser markant slid af sensorhætten Fejlsøgning Diagnostik- og testmenu Diagnostik- og testmenuen viser aktuelle og historiske oplysninger om LDO-sensoren. Hvis du vil åbne diagnostik- og testmenuen, skal du gå til MENU>SENSOR SETUP>[Vælg sensor]>VEDLIGEHOLDELSE. 60 Dansk Se Tabel 5. Tabel 5 Vedligeholdelsesmenu Indstilling Beskrivelse Sensorinformation Softwareversion - viser den installerede softwareversion Startprogram - viser det installerede startprogran Driverversion - viser den installerede driverversion Partikode for sensorhætte Viser sensorhættens produktionsparti Serienummer Sensors serienummer Forstærkningskorrektion Juster kalibreringens stigningsværdi. Område: 0,50 til 2,00 Offset korrektion Juster kalibreringens forskydningsværdi (mg/L eller ppm) Område: –3,00 til +3,00 Fasediagnosticering Viser fasen for alle, røde og blå bølgelængder. Opdaterer hvert sekund. Diagnosticering af amplitude Viser amplituden for røde og blå bølgelængder. Opdateres hvert sekund. Dage til rengøring Viser antal dage, før næste planlagte, manuelle rengøring skal udføres. Sensorens levetid Viser antal dage, før næste planlagte udskiftning af sensorhætten skal udføres.. Fejlliste Hvis der opstår en fejl, blinker teksten på målingsskærmbilledet. Output bestemmes af kontrolenhedens indstillinger. Se brugervejledningen til kontrolenheden for at få flere oplysninger. Hvis du vil se de aktuelle sensorfejl, skal du gå til MENU>SENSORDIAGNOSTICS>[Vælg sensor]>FEJLLISTE. Se Tabel 6. Tabel 6 Fejlliste for LDO-sensoren Fejl Mulig årsag Løsning Rød amplitude er for lav. (Værdien er under 0.01) Fjern sensorhætten, og installer den igen. eller Sensorhætten er ikke installeret eller er ikke installeret korrekt. Blå amplitude er for lav. (Værdien er under 0.01) Lysets vej er blokeret i sensorhætten. Undersøg indersiden af sensorhætten og linsen. Sensoren fungerer ikke korrekt. Kontroller, at LED-indikatoren blinker. Kontakt producenten. Advarselsliste Når advarselsikonet blinker (sc100 og sc200), eller når skærmbilledet bliver gult (sc1000), vises en meddelelse nederst i målingsskærmbilledet. På sc1000 bliver skærmbilledet gult for at vise en advarsel. Hvis du vil se de aktuelle sensorfejl, skal du gå til MENU>SENSOR DIAGNOSTICS>[Vælg sensor]>WARNING LIST (MENU>DIAGNOSTIK>[Vælg sensor]>ADVARSELSLISTE). Se Tabel 7. Tabel 7 Sensors advarselsliste Advarsel Definition Opløsning EEPROM-opsætningsfejl Lageret er beskadiget. Værdierne er angivet til standardindstillingerne. Kontakt teknisk support. EEPROM-fejl Dansk 61 Tabel 7 Sensors advarselsliste (fortsat) Advarsel Definition Opløsning Temperatur < 0 °C Procestemperaturen er under 0 °C (32 °F) Øg procestemperaturen eller afbryd anvendelsen, indtil procestemperaturen ligger inden for det angivne interval for sensoren. Temperatur > 50 °C Procestemperaturen er over 50 °C (120 °F) Reducer procestemperaturen eller afbryd anvendelsen, indtil procestemperaturen ligger inden for det angivne interval for sensoren. Rød amplitude er for lav. Værdien falder under 0,03 Se Fejlliste på side 61 . Rød amplitude er for høj. Værdien er over 0,35 Kontakt teknisk support. Blå amplitude er for lav. Værdien er under 0,03 Se Fejlliste på side 61. Blå amplitude er for høj. Værdien er over 0,35 Kontakt teknisk support. Lot nummer på sensorhætte mangler. Sensorhætten er blevet beskadiget. Koden nulstilles automatisk til standardhætte- og partikoderne. Udfør proceduren for sensorens starthætte. Hvis der ingen starthætte til sensoren findes, kontaktes den tekniske supportafdeling. Hændelsesliste Hændelseslisten indeholder en log over tilpasning af, hvordan sensoren registrerer data. Hvis du vil se sensorhændelserne, skal du gå til MENU>SENSORDIAGNOSTICS>[Vælg sensor]>HÆNDELSESLISTE. Se Tabel 8. Tabel 8 Hændelsesliste til sensoren Hændelse Beskrivelse Ændring i højde/trykenhed Det atmosfæriske tryk eller højdeenhederne er ændrede. Ændring i højde/tryk Værdien for højde eller atmosfærisk tryk har ændret sig. Ændring i temperatur Temperaturenheden er ændret. Ændring i enhed En måleenhed er ændret. Ændring i salinitetindhold Værdien for salinitetindhold er ændret. Reset (Nulstil) Sensorindstillingerne er blevet nulstillet til standardværdierne. Ændring i sensoropsætning Sensoropsætningen er ændret. Ændring i rengøringsinterval Perioden mellem sensorrengøringerne er ændret. Ændring i sensorens levetid Perioden mellem udskiftningerne af sensorhætten er ændret. 62 Dansk Użytkowanie Konfiguracja czujnika Aby wprowadzić informacje identyfikacyjne czujnika i zmienić opcje obsługi i przechowywania danych, należy przejść do menu Ustawienia. Informacje na temat montażu czujnika można znaleźć w podręczniku użytkownika. Upewnij się, że wszystkie wartości w menu Ustawienia są prawidłowe dla danego zastosowania. 1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA. 2. Wybierz opcję, ENTER. Listę dostępnych opcji przedstawiono w poniższej tabeli. Opcja Opis Nazwa Zmienia nazwę czujnika, wyświetlaną na górze ekranu pomiarowego. Nazwa nie może być dłuższa niż 10 znaków i może stanowić dowolną kombinację liter, cyfr, odstępów i znaków interpunkcyjnych. Jednostka Temperatura — umożliwia wybranie jednostek temperatury °C (wartość domyślna) lub °F. Pomiar — umożliwia wybranie jednostek miar w mg/L, ppm lub %. Wysokość n.p.m./ciśnienie — umożliwia wybranie jednostek wysokości w m lub ft bądź wybranie jednostek ciśnienia atmosferycznego w mmHg lub torach. (Wartość domyślna = 0 ft) Wysokość n.p.m./ciśnienie Wprowadź wartość wysokości nad poziom morza lub ciśnienia atmosferycznego. Wartość ta musi być dokładna, aby zakończyć pomiar % nasycenia i kalibracji w powietrzu. (Domyślnie = 0 ft). Zasolenie Wprowadź wartość zasolenia. Zakres zasolenia: 0,00 do 250,00 części na tysiąc (‰). (Wartość domyślna = 0) Uśrednianie sygnału Ustawienie interwału czasowego dla średniej sygnału w sekundach Interwał czyszczenia Ustawienie interwału czasowego dla ręcznego czyszczenia czujnika w dniach (Wartość domyślna = 0 dni. Wartość 0 dni wyłącza międzyczasy czyszczenia.) Resetuj interwał czyszczenia Ustawienie interwału czasowego na ostatni zapisany interwał czasowy czyszczenia Interwał rejestracji danych Umożliwia określenie interwału czasowego przechowywania danych w rejestrze: 0,5, 1, 2, 5, 10, 15 (domyślnie), 30, 60 minut. Resetuj Przywraca konfigurowalne wartości domyślne dla czujnika. Nie zmienia ustawienia krzywej lub offsetu. Wprowadzenie wartości ciśnienia atmosferycznego Ustawienie fabryczne dla ciśnienia atmosferycznego (powietrza) wynosi 0 ft, według poziomu morza. Aby zmienić wartość domyślną, wykonaj czynności opisane w tej procedurze. Regulację ciśnienia powietrza przeprowadza się według wysokości nad poziom morza lub w jednostkach ciśnienia (preferowane). Uwaga: Dokładne ciśnienie powietrza ma krytyczne znaczenie dla kalibracji powietrza nasyconego. Używaj tylko ciśnienia bezwzględnego, bez korekt. Jeśli ciśnienie absolutne powietrza nie jest znane, zastosuj wysokość według lokalizacji. Polski 63 1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA>JEDNOSTKA>CIŚNIENIE POWIETRZA/WYSOKOŚĆ N.P.M. 2. Wybierz jedną z wymienionych jednostek pomiarowych: Opcja Opis Wysokość n.p.m. (stopy) Stopa (ft) — jednostka pomiarowa wysokości Wysokość n.p.m. (m) Metry — jednostka metryczna pomiaru wysokości Ciśnienie powietrza w mmHg Milimetry słupa rtęci — jednostka metryczna pomiaru ciśnienia absolutnego powietrza Ciśnienie powietrza w torach Jednostka pomiarowa ciśnienia absolutnego powietrza 3. Potwierdzić wybór. Na ekranie wprowadzania wartości pojawią się wybrane jednostki. 4. Wprowadź wartość, a następnie potwierdź. Wprowadzanie wartości korekcji zasolenia Pomiary rozpuszczonego tlenu w próbkach soli mogą pokazać pozorną wartość DO (rozpuszczonego tlenu), która bardzo różni się od wartości rzeczywistej DO. Do skorygowania wpływu rozpuszczonych soli w próbce wprowadza się współczynnik korygujący zasolenie. Uwaga: Jeśli obecność lub ilość zasolenia w procesie nie jest znana, skonsultuj się z kadrą inżynierską zakładu przetwarzania odpadów. 1. Użyj miernik przewodności do pomiaru przewodności próbki w mS/cm w temperaturze odniesienia 20 °C (68 °F). 2. Zobacz Tabela 1, aby ocenić współczynnik korygujący zasolenie w liczbie części na tysiąc (‰) nasycenia. Uwaga: Stężenie jonów chloru, w g/kg jest równe stężeniu chlorków w próbce. Zasolenie jest obliczane ze wzoru: zasolenie = 1,80655 × stężenie chlorków. Zasolenie może być obliczane z według zależności w sekcji 2520 B dokumentu Standardowe metody badania wody i ścieków.1, 3. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA>ZASOLENIE. 4. Wprowadź współczynnik korygujący zasolenie i potwierdź. 1 Standard Methods for the Examiniation of Water and Wastewater (Standardowe metody badania wody i ścieków), wydanie 20. Wydawcy Lenore S. Clesceri, Arnold E. Greenberg i Andrew D. Eaton, str. 2-48-2-29 (1998). Zależność pomiędzy rozpuszczalnością chlorków i tlenu jest w tym samym dokumencie w 4500-O:I str. 4-131. 64 Polski Tabela 1 Nasycenie zasolenia (‰) na wartość przewodności (mS/cm) mS/cm ‰ mS/cm ‰ mS/cm ‰ mS/cm ‰ 5 3 16 10 27 18 38 27 6 4 17 11 28 19 39 28 7 4 18 12 29 20 40 29 8 5 19 13 30 21 42 30 9 6 20 13 31 22 44 32 10 6 21 14 32 22 46 33 11 7 22 15 33 23 48 35 12 8 23 15 34 24 50 37 13 8 24 17 35 25 52 38 14 9 25 17 36 25 54 40 15 10 26 18 37 26 Kalibracja pomiarów Czujnik jest skalibrowany według specyfikacji fabrycznej. Producent nie zaleca kalibracji, chyba że jej przeprowadzenie jest wymagane okresowo zgodnie z odnośnymi przepisami. Jeśli kalibracja jest wymagana, należy przed kalibracją zrównoważyć czujnik w cieczy procesowej. Nie należy kalibrować czujnika podczas jego konfigurowania. Tabela 2 przedstawia opcje kalibracji. Tabela 2 Opcje kalibracji Opcja Opis Kalibracja powietrza Zalecana metoda kalibracji. Kalibracja ta zmienia wartości krzywej. Kalibracja Kalibracja według porównania z przenośnym miernikiem DO ( tlenu rozpuszczonego). Kalibracja ta zmienia wartość offsetu. Resetowanie kalibracji Przywraca wzmocnienie kalibracji (krzywej) i offset do domyślnych ustawień fabrycznych: wzmocnienie domyślne=1.0; offset domyślny=0.0 Kalibracja powietrza Uwagi przeznaczone dla użytkowników: • • • • • Upewnij się, że w worku kalibracyjnym jest woda. Upewnij się, że uszczelka pomiędzy workiem kalibracyjnym i korpusem czujnika jest szczelna. Upewnij się, że czujnik jest suchy podczas kalibracji. Upewnij się, że ciśnienie powietrza/ustawienie wysokości jest prawidłowe w lokalizacji kalibracji. Zapewnij wystarczająco dużo czasu na ustabilizowanie się temperatury czujnika do temperatury w lokalizacji worka kalibracyjnego. W przypadku dużej różnicy temperatur pomiędzy cieczą procesową i lokalizacją kalibracji jej ustabilizowanie może trwać do 15 minut. 1. Wyjmij czujnik z cieczy procesowej. Do czyszczenia czujnika użyj wilgotnej szmatki. 2. Umieść cały czujnik w worku kalibracyjnym z wodą o objętości 25-50 ml. Upewnij się, że nakładka czujnika nie jest w kontakcie z wodą wewnątrz worka kalibracyjnego, a na jej powierzchni nie ma żadnych kropel wody. 3. Zapewnij uszczelnienie wokół korpusu czujnika używając do tego taśmy gumowej, cięgna lub ręki. Polski 65 4. Odczekaj 15 minut aż przyrząd się ustabilizuje przed kalibracją. W czasie stabilizacji chroń worek kalibracyjny przed bezpośrednim światłem słonecznym. 5. Upewnij się, że aktualne bezwzględne ciśnienie powietrza oraz wysokość n.p.m. są poprawnie skonfigurowane. Uwaga: Producent zaleca jako najlepszą praktykę stosowanie bezwzględnego lub rzeczywistego ciśnienia powietrza. 6. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KALIBRACJA>KALIBRACJA POWIETRZA. 7. Wybierz opcję sygnału wyjściowego używanego podczas kalibracji: Opcja Opis Aktywne Podczas procedury kalibracji instrument wysyła aktualną mierzoną wartość wyjściową. Wstrzymaj Podczas procedury kalibracji wartość wyjściowego sygnału czujnika jest utożsamiana z aktualnie mierzoną wartością. Transfer Podczas procedury kalibracji jest wysyłana wartość zadana sygnału wyjściowego. Informacje na temat zmiany wartości zadanej można znaleźć w podręczniku użytkownika urządzenia sterującego. 8. Sterownik wyświetla komunikat „Włóż cały czujnik do worka z wodą”. Odczekaj, aż wartość się ustabilizuje. Naciśnij klawisz ENTER, aby zaakceptować wartość ustabilizowaną. Opcjonalnie pozwól na kontynuowanie kalibracji, dopóki na wyświetlaczu nie pojawi się komunikat „Pomyślnie wykonano zadanie” . 9. Po ukończeniu kalibracji czujnika, umieść go w cieczy procesowej. Naciśnij klawisz ENTER. Rysunek 1 Procedura kalibracji powietrza Jeśli nie nastąpi ustabilizowanie się wartości, na wyświetlaczu pojawi się napis „Unable to Calibrate” (Nie można dokonać kalibracji), a następnie komunikaty o błędach. Tabela 3 pokazuje komunikat o błędzie i rozwiązanie problemu kalibracji. Tabela 3 Komunikaty o błędach dotyczące kalibracji powietrza Komunikat Opis Rozwiązanie Kalibracja nieudana! Korekcja wzmocnienia za wysoka. Obliczona wartość wzmocnienia jest zbyt wysoka. Powtórz kalibrację. Kalibracja nieudana! Korekcja wzmocnienia za niska. Obliczona wartość wzmocnienia jest zbyt niska. Powtórz kalibrację. Kalibracja nieudana! Niestabilna Wartość nie uległa stabilizacji w przewidzianym czasie kalibracji. Powtórz kalibrację. 66 Polski Kalibracja poprzez porównanie Ta metoda kalibracji używa alternatywnego czujnika dołączonego do miernika podręcznego. 1. Wstaw alternatywny czujnik do cieczy procesowej. Wstaw drugi czujnik możliwie blisko czujnika pierwszego. 2. Poczekaj, aż wartość DO (rozpuszczonego tlenu) się ustabilizuje. 3. Na sterowniku pierwszego czujnika przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KALIBRACJA>KALIBRACJA. 4. Wybierz opcję sygnału wyjściowego używanego podczas kalibracji: Opcja Opis Aktywne Podczas procedury kalibracji instrument wysyła aktualną mierzoną wartość wyjściową. Wstrzymaj Podczas procedury kalibracji wartość wyjściowego sygnału czujnika jest utożsamiana z aktualnie mierzoną wartością. Transfer Podczas procedury kalibracji jest wysyłana wartość zadana sygnału wyjściowego. Informacje na temat zmiany wartości zadanej można znaleźć w podręczniku użytkownika urządzenia sterującego. 5. Urządzenie sterujące pokazuje: • „Czy odczyt jest stabilny?” • Aktualny pomiar rozpuszczonego tlenu (DO) • Aktualny pomiar temperatury 6. Po ustabilizowaniu się pomiaru naciśnij ENTER. Na wyświetlaczu pojawi się ekran wejścia. Uwaga: Zwykle pomiar stabilizuje się w ciągu 2 do 3 minut. Jeśli nie nastąpi ustabilizowanie się wartości, na wyświetlaczu pojawi się napis „Unable to Calibrate” (Nie można dokonać kalibracji), a następnie komunikaty o błędach. Tabela 4 pokazuje komunikat o błędzie i rozwiązanie problemu kalibracji. Tabela 4 Komunikaty o błędach dotyczące kalibracji próbki Komunikat Opis Rozwiązanie Kalibracja nieudana! Przesunięcie za duże. Obliczona wartość offsetu jest zbyt wysoka. Powtórz kalibrację. Kalibracja nieudana! Przesunięcie za małe. Obliczona wartość offsetu jest zbyt niska. Powtórz kalibrację. Kalibracja nieudana! Niestabilna Wartość nie uległa stabilizacji w przewidzianym czasie kalibracji. Powtórz kalibrację. Zamykanie procedury kalibracji 1. Podczas kalibracji naciśnij przycisk BACK. Zostaną wyświetlone trzy opcje: Opcja Opis Anuluj Kończy kalibrację. Należy rozpocząć procedurę kalibracji od nowa. Powróć do procedury kalibracji Powraca do aktualnej kalibracji. Wyjście Tymczasowo przerywa kalibrację. Dostęp do innych pozycji menu jest dozwolony, podczas gdy kalibracja jest nadal kontynuowana w tle. Można rozpocząć kalibrację drugiego czujnika (jeśli jest używany). Aby powrócić do kalibracji, naciśnij klawisz MENU i wybierz kolejno Ustawienia czujnika, [Wybór czujnika]. 2. Wybierz jedną z opcji. Potwierdź. Polski 67 Reset do ustawień fabrycznych kalibracji Ustawienia kalibracji można zresetować do ustawień fabrycznych. Wartości wzmocnienia i offsetu są ustawione na 1,0 i 0,0, odpowiednio. 1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KALIBRACJA>RESETUJ KALIBRACJĘ. 2. Na ekranie pojawi się komunikat o konfiguracji. Potwierdź reset czujnika do krzywej kalibracji ustawień fabrycznych. Konserwacja NIEBEZPIECZEŃSTWO Wiele zagrożeń. Tylko wykwalifikowany personel powinien przeprowadzać prace opisane w tym rozdziale niniejszego dokumentu. NIEBEZPIECZEŃSTWO Zagrożenie wybuchem. Nie należy podłączać ani odłączać żadnych elektrycznych komponentów i obwodów od urządzeń przed wyłączeniem zasilania, chyba że obszar nie jest objęty zagrożeniem. NIEBEZPIECZEŃSTWO Zagrożenie wybuchem. Zastąpienie komponentów innymi może spowodować, że urządzenia nie będzie można używać w niebezpiecznych lokalizacjach Klasy 1, Dział 2. Nie wolno wymieniać żadnych komponentów, chyba że zasilanie zostało wyłączone, a w pobliżu brak czynników stanowiących zagrożenie. POWIADOMIENIE Wersja certyfikowana tego produktu dla miejsc stwarzających zagrożenie nie spełnia wymogów dyrektywy 94/9/WE (Dyrektywa ATEX). Plan konserwacji Plan konserwacji uwzględnia minimalne międzyczasy wykonywania okresowych czynności konserwacyjnych. Czynności konserwacyjne należy wykonywać częściej, jeśli sposób użytkowania urządzenia prowadzi do szybszego zanieczyszczania elektrod. Uwaga: Nie demontować sondy w celu konserwacji lub czyszczenia. Praca konserwacyjna do wykonania Zalecana minimalna częstotliwość Czyszczenie czujnika 90 dni Sprawdzenie, czy czujnik nie jest uszkodzony 90 dni Kalibracja czujnika Zgodnie z zaleceniami według odnośnych przepisów Czyszczenie czujnika Zewnętrzną powierzchnię czujnika czyścić miękką szmatką. Uwaga: Po wyjęciu nakrętki pomiarowej czujnika do czyszczenia, nie należy narażać wnętrza nakrętki pomiarowej na bezpośrednie działanie promieni słonecznych przez dłuższy czas. Ustawianie i zmiana interwału czasowego czyszczenia Warunki stosowania mogą wymagać krótszych lub dłuższych odstępów czasu pomiędzy ręcznym czyszczeniem czujnika. Interwał czasowy ustawiony fabrycznie wynosi 0 dni. Aby zmienić interwał, wykonaj czynności wymienione w tej procedurze. 68 Polski 1. Przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>USTAWIENIA>INTERWAŁ CZYSZCZENIA. 2. Zmień pokazywaną wartość w razie potrzeby. Potwierdź zmianę. • Aby wyłączyć interwał czasowy czyszczenia, ustaw wartość na „0”. Zmiana nakrętki pomiarowej czujnika OSTRZEŻENIE Potencjalne zagrożenie wybuchem. Nnakrętka pomiarowa ustawiania czujnika nie jest przystosowane do używania w miejscach niebezpiecznych. Zamienne nakrętki pomiarowe czujników i nakrętki pomiarowe są dostarczane razem z instrukcją instalacji. Aby zmienić nakrętkę, zobacz dołączone instrukcje. Po zamontowaniu nowej nakrętki czujnika upewnij się, że numer partii na nakrętce jest taki sam, jak numer odczytywany przez Modbus. Czujnik pobiera informacje kalibracyjne z nakrętki czujnika. Aby uzyskać najlepszą wydajność i dokładność, wymieniaj nakładkę czujnika: • Co dwa latalub częściej w razie konieczności • Kiedy normalna kontrola wykazuje znaczną erozję nakrywki czujnika. Rozwiązywanie problemów Menu diagnostyki i testów Menu diagnostyki i testów wyświetla bieżące i historyczne informacje dotyczące czujnika LDO. Aby uzyskać dostęp do menu diagnostyki i testów, przejdź do MENU>USTAWIENIA CZUJNIKA>[Wybierz czujnik]>KONSERWACJA. Patrz Tabela 5. Tabela 5 Menu konserwacji Opcja Opis Informacja o czujniku Wersja oprogramowania — wyświetla informacje o wersji zainstalowanego oprogramowania Program uruchomieniowy — wyświetla informacje o wersji zainstalowanego programu uruchomieniowego Wersja oprogramowania — wyświetla informacje o wersji zainstalowanego sterownika programowego Kod partii nakrętki czujnika Pokazuje kod partii produkcyjnej na nakrywce czujnika Numer seryjny Numer seryjny czujnika Korekcja wzmocnienia Ustawienie wartości wzmocnienia kalibracji. Zakres: 0,50 do 2,00 Korekcja przesunięcia Ustawienie wartości offsetu kalibracji (mg/L lub ppm). Zakres: –3,00 do +3,00 Diagnostyka fazy Pokazuje fazę dla całkowitej, czerwonej, niebieskiej długości fali. Aktualizuje raz na sekundę. Diagnostyka amplitudy Pokazuje amplitudę dla całkowitej, czerwonej, niebieskiej długości fali. Aktualizuje raz na sekundę. Polski 69 Tabela 5 Menu konserwacji (ciąg dalszy) Opcja Opis Dni do czyszczenia Pokazuje liczbę dni do następnego zaplanowanego czyszczenia ręcznego. Trwałość czujnika Pokazuje liczbę dni do następnej zaplanowanej wymiany nakrętki pomiarowej czujnika.. Lista błędów Jeśli wystąpi błąd, odczyt miga na ekranie pomiarowym. Zachowanie sygnału wyjściowego zależy od ustawień sterownika. Więcej informacji można znaleźć w podręczniku użytkownika sterownika. Aby wyświetlić aktualne błędy czujnika, przejdź do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz czujnik]>LISTA BŁĘDÓW. Patrz Tabela 6. Tabela 6 Błędy czujnika LDO Błąd Możliwa przyczyna Rozwiązanie Amplituda światła czerwonego za niska. (Wartość niższa niż 0,01) Nakrętka pomiarowa czujnika nie jest zainstalowana lub jej zainstalowanie nie jest prawidłowe. Wyjmij nakrętkę pomiarową czujnika i zainstaluj ją ponownie. lub Amplituda światła niebieskiego za niska. (Wartość niższa niż 0,01) Promień świetlny jest blokowany Sprawdź nakrętkę pomiarową w nakrętce pomiarowej czujnika. czujnika od środka i obiektyw. Czujnik nie działa poprawnie. Upewnij się, że wskaźnik LED miga. Skontaktuj się z producentem. Lista ostrzeżeń Kiedy miga ikona ostrzegania (sc100 i sc200) lub gdy ekran zmienia kolor na żółty (sc1000), komunikat pojawi się na dole ekranu pomiarowego. W przypadku sc1000 ekran zmienia kolor na żółty i pojawia się komunikat. Aby wyświetlić aktualne ostrzeżenia czujnika, przejdź do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz czujnik]>LISTA OSTRZEŻEŃ. Patrz Tabela 7. Tabela 7 Lista ostrzeżeń czujnika Ostrzeżenie Opis Rozwiązanie Błąd ustawień EEPROM Pamięć masowa jest uszkodzona. Wartości zostaną ustawione na fabryczne. Skontaktuj się z działem pomocy technicznej. Temperatura <0°C Temperatura cieczy procesowej jest poniżej 0 °C (32 °F) Zwiększyć temperaturę cieczy procesowej lub przerwać procedurę aż temperatura cieczy procesowej znajdzie się w zakresie specyfikacji czujnika. Temperatura >50°C Temperatura cieczy procesowej jest powyżej 50 °C (120 °F) Zmniejszyć temperaturę cieczy procesowej lub przerwać procedurę aż temperatura cieczy procesowej znajdzie się w zakresie specyfikacji czujnika. Amplituda światła czerwonego za niska. Wartość spadła poniżej 0,03 Zobacz Lista błędów na stronie 70 . Amplituda światła czerwonego za wysoka. Wartość jest większa niż 0,35 Skontaktuj się z działem pomocy technicznej. Amplituda światła niebieskiego za niska. Wartość jest poniżej 0,03 Zobacz Lista błędów na stronie 70. Błąd EEPROM 70 Polski Tabela 7 Lista ostrzeżeń czujnika (ciąg dalszy) Ostrzeżenie Opis Rozwiązanie Amplituda światła niebieskiego za wysoka. Wartość jest większa niż 0,35 Skontaktuj się z działem pomocy technicznej. Brak kodu partii nakrętki czujnika. Kod nakrętki pomiarowej czujnika został uszkodzony. Kod został zresetowany automatycznie do kodu fabrycznego nakrywki i partii. Zakończ procedurę nakrętki pomiarowej czujnika. Jeśli nakrętka ustawiania czujnika nie jest dostępna dla nakrętki czujnika, skontaktuj się z działem pomocy technicznej. Lista zdarzeń W ramach listy zdarzeń prowadzony jest dziennik zmian sposobu zapisu danych przez czujnik. Aby wyświetlić zdarzenia czujnika, przejdź do MENU>DIAGNOSTYKA CZUJNIKA>[Wybierz czujnik]>LISTA ZDARZEŃ. Patrz Tabela 8. Tabela 8 Lista zdarzeń czujnika Zdarzenie Opis Altitude/Pressure unit change (Zmiana jednostek wysokości n.p.m./ciśnienia) Zostały zmienione jednostki ciśnienia atmosferycznego lub wysokości. Altitude/Pressure change (Zmiana wysokości n.p.m./ciśnienia) Została zmieniona wartość ciśnienia atmosferycznego lub wysokości. Temperature change (Zmiana temperatury) Zostały zmienione jednostki temperatury. Unit change (Zmiana jednostki) Została zmieniona nowa jednostka pomiarowa. Salinity change (Zmiana zasolenia) Została zmieniona wartość zasolenia. Resetuj Ustawienia czujnika zostały zresetowane do wartości domyślnych. Sensor setup change (Zmiana ustawień czujnika) Zostało zmienione ustawienie czujnika. Cleaning interval change (Zmiana interwału czyszczenia) Został zmieniony międzyczas czyszczenia czujnika. Sensor life change (Zmiana trwałości czujnika) Został zmieniony międzyczas wymiany nakrywki czujnika. Polski 71 *DOC273.98.90592* HACH COMPANY World Headquarters P.O. Box 389, Loveland, CO 80539-0389 U.S.A. Tel. (970) 669-3050 (800) 227-4224 (U.S.A. only) Fax (970) 669-2932 [email protected] www.hach.com © HACH LANGE GMBH Willstätterstraße 11 D-40549 Düsseldorf, Germany Tel. +49 (0) 2 11 52 88-320 Fax +49 (0) 2 11 52 88-210 [email protected] www.de.hach.com Hach Company/Hach Lange GmbH, 2017. All rights reserved. Printed in Germany. HACH LANGE Sàrl 6, route de Compois 1222 Vésenaz SWITZERLAND Tel. +41 22 594 6400 Fax +41 22 594 6499
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74

Hach LDO Addendum-Operation

Categoría
Medición
Tipo
Addendum-Operation

En otros idiomas