Rotronic HP32 El manual del propietario

Tipo
El manual del propietario

Este manual también es adecuado para

www.rotronic.comEnglish
12.8000.2505E
HYGROPALM HP31/32/GTS
Short Instruction Manual
1 GENERAL DESCRIPTION
The HP3x-Series handheld instrument is a power full, multifunctional device which measures,
displays and logs temperature, humidity and calculated parameters. The series consist of three
different devices. Ensure devices have the latest compatible rmware. For more information
visit www.rotronic.com.
Order Code HP31 HP32 HP-GTS
Compatible
probes
Fixed probe HC2 and HC2A-S
probes. Probes must be
ordered separately
Fixed probe
2 DEVICE OVERVIEW
Make sure that the plug head is not plugged
in with reversed polarity.
3 GENERAL OPERATION
3.1 SOFTWARE HW4 LITE INSTALLATION
Data analysis, and general setting of the device can be easily done with the free HW4 Software.
To get the software, download the latest HW4 Software from the Rotronic Homepage. While
the software always remains the same, the corresponding key unlocks the desired version. For
the free Lite version, no key is needed and up to 3 Rotronic devices can be connected. Probes
count as one device.
3.2 BATTERY, STAND-BY AND AUTO SWITCH
The HP3x has an integrated lithium battery. Simply connect the device to an USB port with the
delivered cable to charge it. The device has a stand-by and an auto switch off feature. After
5 minutes without user interaction the display is switched off, after 10 minutes the device is
switched off to save battery. This feature does not affect data logging operation.
3.3 DISPLAY AND HOME SCREEN
3.4 MASTER RESET
There are a few instances in which the HP3x device may need to be reset. These include the
following:
To restore to factory default settings.
The HP3x is not functioning properly (value are frozen).
Performing a reset will erase user data. Performing a Master Reset: Press and hold the reset
button on the backside of the device with a thin pen or an ofce clammy for 3 sec.
4 GENERAL SETTINGS
4.1 LANGUAGE
Main menu [OK] Settings Language
Available languages: English, Deutsch, Français, Italiano
4.2 DATE/TIME
Main menu [OK] Settings Date / Time
The following settings can also be set beside the date and time.
Date format: DIN, US, ISO
Time format: 12 h, 24 h
The date and time must be set correctly for proper operation of the device.
Please note that if the battery is completely discharged, the handheld device must be time-chro-
nized again with the HW4.
4.3 UNITS
Main menu [OK] Settings Units
Your options are as follow:
Distance: m, ft
Temperature: °C, °F
Pressure: hPa, mmHg
Weight: kg, lbs
[POWER] Switches the HP32 on or off.
Probe connector
Tripod socket
Reset button
Integrated magnet
Lanyard xation
USB port
[DOWN] Cursor down
[LEFT]
[RIGHT]
Action buttons, their action are indicated by
the on-screen labels.
[UP] Cursor up
Parameter selection (home screen)
Status Bar
Time and date
Hold indicator
Log indicator
Battery status
Measured values
Action Buttons labels
[OK] Opens the main menu / submenus
Conrm entries
4.4 CALCULATED PSYCHROMETRIC PARAMETERS
Beside relative humidity and temperature, the HP32 can display 2 of the following 10 psychro-
metric parameters:
Dew / Frost point (Dp/Fp)
Wet bulb temperature (Tw)
Enthalpy (H)
Vapor concentration (Dv)
Specic humidity (Q)
Mixing ration by weight (R)
Vapor pressure (E)
Saturation vapor pressure (Ew)
Saturation vapor density (SVD)
Select the parameters that you want to log and/or see on the home screen within:
Main menu [OK] Settings Displayed calculated parameters
You can change the order of values on the home screen by [UP] on the home screen.
You can change the atmospheric pressure constant used in calculations in:
Main menu Settings Atmospheric pressure
5 SAVING DATA
5.1 HOLD/CAPTURE AND SPOT MEASUREMENTS
Freeze the displayed values on the home screen by pressing the [Hold/Capture] action button
on the home screen. Those values can then be:
Saved as a spot measurement with [Capture]
Released again with [Release]
5.2 DATA LOGGING
Program or start the automatic logging at regular interval with the [Log] action button. Dene
the storage location, the interval and, if you want, a start and stop time, then start the logging
operation by pressing the [Start] action button.
Your device will be automatically switched on at the given start time to start the logging.
The main menu is not accessible while data logging is active. Spot measurements are,
however, still possible.
You must name storage locations before use. Simply use the [Rename] action button
when selecting a storage location to assign it a name.
6 VIEWING SAVED DATA
6.1 SPOT MEASUREMENTS
Review the spot measurements by selecting their storage location within:
Main Menu [OK] Memory – Capture
6.2 LOGGED DATA
Review the logged data by selecting its storage location within:
Main Menu [OK] Memory – Log
Switch between graphic displays and MIN / MAX / AVG values of the 4 parameters with [UP]
and [DOWN].
7 ALARM
Set up upper, lower limits as well as hysteresis for every displayed parameter in:
Main Menu [OK] Alarms
Broken alarm limits are shown in red on the home screen.
To enable an acoustic signal for an alarm:
Main Menu [OK] Settings Buzzer
8 ADJUSTMENT
The HP3X has a humidity and temperature adjustment function so that you can adjust directly
with the handheld instrument. The instrument can make a 1-point adjustment for temperature
and a 1-point or 3-point adjustment for humidity.
Main Menu [OK] Adjustment
Select Humidity or Temperature with the arrow keys and conrm with OK.
Example of sequence for 3-point humidity adjustment:
Reference value 1 10 %rh
Reference value 2 35 %rh
Reference value 3 80 %rh
The value of the reference can be entered with the keypad. The attached probe shows the
current measured value. After entering the rst reference value (10 %rh), press OK to conrm
“Save & Continue” and enter the next reference value (35 %rh).
When all three reference values have been entered, press OK to conrm Save & Continue”
again and adjustment is nished. The last adjustment date is now listed under Adjustment.
9 TECHNICAL DATA
HP31 HP32 HP-GTS
Compatible probes Fixed HC2 and HC2A-S
probes. Probes
must be ordered
separately
Fixed
Application range -10…60 °C | 0…100 %rh (non-cond.)
Probe application range -1060 °C Depends on probe
for example HC2A-S
±0.8 %rH / ±0.1 °C
-1060 °C
Accuracy @ 23 °C ±2 %rh / ±0.3 °C ±2 %rh / ±0.3 °C
Functions Spot measurements / Interval logging
MIN / MAX / AVG / MKT
Logging interval 1 s…24 h
Memory capacity 8 x 8000 data points
Psychrometric
calculations
Dew / Frost point (Dp /Fp)
Wet bulb temperature (Tw)
Enthalpy (H)
Vapor concentration (Dv)
Specic humidity (Q)
Mixing ratio by weight (R)
Vapor pressure (E)
Saturation vapor pressure (Ew)
Saturation vapor density (SVD)
Display refresh rate 1 s (typical)
Integrated Battery 48 h – Logging every 30 s, screen off
10 h – Screen always on (typical)
PC Interface Micro-USB port, HW4 compatible
Housing Material ABS, TPR
IP Protection IP65
Dimension 160 x 63 x 30 mm
Weight 185 g
10 DELIVERED
HygroPalm HP-31/32/GTS
Soft case
Micro-USB service cable (AC0006)
Belt buckle set, lanyard and certicate
Belt Buckle Set
HP32 with HC2S-S probe (order separately)
www.rotronic.comDeutsch
12.8000.2505D
HYGROPALM HP31/32/GTS
Kurzbedienungsanleitung
1 ALLGEMEINE BESCHREIBUNG
Das Handmessgerät der Serie HP3x ist ein leistungsfähiges Multifunktionsgerät, das Tempe-
ratur, Feuchte und berechnete Parameter anzeigt. Die Serie besteht aus drei verschiedenen
Modellen. Stellen Sie sicher, dass die Geräte die aktuellste kompatible Firmware haben. Für
weitere Informationen besuchen Sie www.rotronic.com.
Bestell-Code HP31 HP32 HP-GTS
Kompatible
Fühler
Integrierter Fühler HC2- und HC2A-S-Füh-
ler. Die Fühler müssen
separat bestellt werden.
Integrierter Fühler
2 GERÄTEÜBERSICHT
Stellen Sie sicher, dass der Steckerkopf nicht
mit verkehrter Polarität eingesteckt ist.
3 ALLGEMEINE BEDIENUNG
3.1 INSTALLATION DER SOFTWARE HW4 LITE
Datenanalyse und allgemeine Geräteeinstellungen lassen sich bequem mit der kostenfreien
HW4-Software vornehmen. Laden Sie sich die aktuelle HW4-Software einfach von der Rotro-
nic-Homepage herunter. Die Software ist immer gleich, mit dem entsprechenden Schlüssel wird
die jeweils gewünschte Version entsperrt. Für die kostenlose Lite-Version wird kein Schlüssel
benötigt, und es können bis zu 3 Rotronic-Geräte angeschlossen werden. Fühler zählen als ein
Gerät.
3.2 BATTERIE, STANDBY UND AUTOMATISCHE ABSCHALTUNG
Das HP3x verfügt über eine integrierte Lithium-Batterie. Schliessen Sie das Gerät zum Aua-
den einfach mit dem mitgelieferten Kabel an einen USB-Anschluss an. Das Gerät verfügt über
eine Standby- und eine automatische Abschaltfunktion. Nach insgesamt 5 Minuten ohne Nut-
zereingriff wird das Display und nach 10 Minuten wird das Gerät ausgeschaltet, um die Batterie
zu schonen. Diese Funktion beeinträchtigt die Datenlogging-Funktion nicht.
3.3 DISPLAY UND STARTBILDSCHIRM
3.4 MASTER-RESET
In einigen Fällen muss das HP3x-Gerät gegebenenfalls zurückgesetzt werden. Dazu gehören
folgende:
Wiederherstellung der Werkseinstellungen.
Das HP3x funktioniert nicht ordnungsgemäss (Werte sind eingefroren).
Bei einem Reset werden alle Benutzerdaten gelöscht. Master-Reset durchführen: Die Reset-Tas-
te auf der Geräterückseite mit einem dünnen Stift oder einer Büroklammer 3 Sekunden lang
gedrückt halten.
4 ALLGEMEINE EINSTELLUNGEN
4.1 SPRACHE
Hauptmenü [OK] Einstellungen Sprache
Verfügbare Sprachen: English, Deutsch, Français, Italiano
4.2 DATUM/UHRZEIT
Hauptmenü [OK] Einstellungen Datum / Zeit
Neben Datum und Uhrzeit können folgende Einstellungen vorgenommen werden.
Datumsformat: DIN, US, ISO
Zeitformat: 12 h, 24 h
Für eine einwandfreie Funktion müssen Datum und Uhrzeit richtig eingestellt sein.
Bitte beachten Sie, dass bei vollständig entladener Batterie das Handgerät erneut mit der
HW4-Software zeitchronisiert werden muss.
4.3 EINHEITEN
Hauptmenü [OK] Einstellungen Einheiten
Die Auswahlmöglichkeiten sind:
Distanz: m, ft
Temperatur: °C, °F
Druck: hPa, mmHg
Gewicht: kg, lbs
Status Bar
Time and date
Hold indicator
Log indicator
Battery status
Measured values
Action Buttons labels
4.4 BERECHNETE PSYCHROMETRISCHE PARAMETER
Neben relativer Feuchte und Temperatur kann das HP32 zwei der folgenden 10 psychrometri-
schen Parameter anzeigen:
Tau- / Frostpunkt (Dp/Fp)
Feuchtkugeltemperatur (Tw)
Enthalpie (H)
Wasserdampfdichte (Dv)
Spezische Feuchte (Q)
Gewichts-Mischungsverhältnis (R)
Wasserdampfdruck (E)
Sättigungsdampfdruck (Ew)
Wasserdampfsättigungsdichte (SVD)
Zur Auswahl der Parameter, die Sie protokollieren und/oder auf dem Startbildschirm anzeigen
wollen, gehen Sie auf:
Hauptmenü [OK] Einstellungen Angezeigte berechnete Parameter
Sie können die Anzeigereihenfolge der Werte auf dem Startbildschirm ändern, indem Sie
auf dem Startbildschirm [AUF] drücken.
Um die in den Berechnungen verwendete Atmosphärendruckkonstante zu ändern, gehen
Sie auf:
Hauptme Einstellungen Atmosphärendruck
5 DATENSPEICHERUNG
5.1 ERFASSEN/SPEICHERN UND PUNKTAUFZEICHNUNGEN
Die auf dem Startbildschirm angezeigten Werte können mittels Betätigung der Aktionstaste
[HALTEN/SPEICHERN] auf dem Startbildschirm eingefroren werden. Diese Werte können dann:
Als Punktaufzeichnung mit [Erfassen] gespeichert werden
Mit [Lösen] wieder losgelassen werden
5.2 DATENAUFZEICHNUNG
Programmieren oder starten Sie die automatische Aufzeichnung in regelmässigen Abständen
mit der Aktionstaste [Aufzeichnen]. Denieren Sie den Speicherort, das Intervall und, falls ge-
wünscht, eine Start- und Stoppzeit; starten Sie dann den Aufzeichnungsvorgang durch Drücken
der Aktionstaste [Start].
Ihr Gerät wird zur vorgegebenen Startzeit automatisch eingeschaltet, um die Aufzeich-
nung zu starten.
Während der Datenaufzeichnung kann nicht auf das Hauptmenü zugegriffen werden.
Punktaufzeichnungen können jedoch weiterhin gemacht werden.
Speicherorte müssen vor der Benutzung benannt werden. Verwenden Sie bei der Auswahl
des Speicherorts einfach die Aktionstaste [Umbenennen], um einen Namen zuzuweisen.
6 ANZEIGE GESPEICHERTER DATEN
6.1 PUNKTAUFZEICHNUNGEN
Zur Prüfung von Punktaufzeichnungen den Speicherort wie folgt auswählen:
Hauptmenü [OK] Speicher – Erfassen
6.2 AUFGEZEICHNETE DATEN
Zur Prüfung der gespeicherten Daten den Speicherort wie folgt auswählen:
Hauptmenü [OK] Speicher – Speichern
Sie können zwischen den graschen Anzeigen und den MIN / MAX / AVG-Werten der 4 Parame-
ter mit [AUF] und [AB] umschalten.
7 ALARM
Zur Einrichtung der unteren und oberen Alarmgrenze sowie der Hysterese für jeden angezeigten
Parameter, gehen Sie auf:
Hauptmenü [OK] Alarme
Überschrittene Alarmgrenzen werden auf dem Startbildschirm rot dargestellt.
Sie können zudem ein akustisches Signal für einen Alarm aktivieren:
Hauptmenü [OK] Einstellungen Warnsignal
8 JUSTIERUNG
Das HP3X verfügt über eine Feuchte- und Temperatur Justage Funktion, sodass Sie direkt mit
dem Handmessgerät justieren können. Das Gerät kann eine 1-Punkt Justage für die Temperatur
und eine 1-Punkt oder 3-Punkte Justage für die Feuchtigkeit.
Hauptmenü [OK] Justierung
Wählen Sie mit den Pfeil Tasten Feuchte oder Temperatur aus und bestätigen mit OK.
Beispiel Reihenfolge 3-Punkte Feuchte Justage:
Referenzwert 1 10 %rF
Referenzwert 2 35 %rF
Referenzwert 3 80 %rF
Der Wert der Referenz kann mittels Tastatur eingegeben werden, wobei der angehängte Fühler
den aktuellen Messwert anzeigt. Nach Eingabe des ersten Referenzwertes (10 %rF) kann mit
der Taste OK «Speichern & Weiter» bestätigt werden und der nächste Referenzwert (35 %rF)
eingegeben werden.
Nachdem alle drei Referenzwerte eingetragen sind, nochmals «Speichern und Weiter» mit der
Taste Ok bestätigen und die Justierung ist abgeschlossen. Das letzte Justierdatum wird nun
unter Justierung aufgeführt.
9 TECHNISCHE DATEN
HP31 HP32 HP-GTS
Kompatible Fühler Fix HC2- und HC2A-S-
Fühler. Die Fühler
müssen separat
bestellt werden.
Fix
Einsatzbereich -10…60 °C | 0…100 %rF (nicht kond.)
Fühler-Einsatzbereich -1060 °C Abhängig vom
Fühler, z. B. HC2A-S
±0,8 %rF / ±0,1 °C
-1060 °C
Genauigkeit @ 23 °C ±2 %rF / ±0,3 °C ±2 %rF / ±0,3 °C
Funktionen Punktaufzeichnung / Intervallspeicherung
MIN / MAX / AVG / MKT
Log-Intervall 1 s…24 h
Messwertspeicher 8 x 8000 Datenpunkte
Psychrometrische
Berechnungen
Tau- / Frostpunkt (Dp/Fp)
Feuchtkugeltemperatur (Tw)
Enthalpie (H)
Wasserdampfdichte (Dv)
Spezische Feuchte (Q)
Gewichts-Mischungsverhältnis (R)
Wasserdampfdruck (E)
Sättigungsdampfdruck (Ew)
Wasserdampfsättigungsdichte (SVD)
Display-Wiederholrate 1 s (typisch)
Integrierte Batterie 48 h – Aufzeichnung alle 30 s, bei ausgeschaltetem Bildschirm
10 h – Bei eingeschaltetem Bildschirm (typisch)
PC-Schnittstelle USB-Micro-Anschluss, HW4-kompatibel
Gehäusematerial ABS, TPR
IP-Schutzart IP65
Abmessungen 160 x 63 x 30 mm
Gewicht 185 g
10 LIEFERUMFANG
HygroPalm HP-31/32/GTS
Softcase
Micro-USB-Servicekabel (AC0006)
Gürtelschnallen-Set, Umhängeband und Zertikat
[STROM] Zum Ein- und Ausschalten des HP32.
Fühler-Anschlussstecker
Stativgewinde
Reset-Taste
Integrierter Magnet
Umhängeband-Befestigung
USB-Anschluss
[AB] Cursor abwärts
[LINKS]
[RECHTS]
Aktionstasten, deren Funktion durch
die Bezeichnung auf dem Bildschirm
gekennzeichnet ist.
[AUF] Cursor aufwärts
Parameterwahl (Homescreen)
[OK] Öffnet Hauptmenü / Untermenüs
Bestätigt Eingaben
Gürtelschnallen-Set
HP32 mit HC2S-S-Fühler (nicht im Lieferumfang enthalten)
www.rotronic.comFrançais
12.8000.2505F
HYGROPALM HP31/32/GTS
Manuel abrégé
1 DESCRIPTION GÉNÉRALE
L’instrument de mesure portatif de la série HP3x est un appareil multifonction puissant qui
afche la température, l’humidité et calcule divers paramètres. La série est composée de trois
modèles différents. Veillez à ce que les appareils soient dotés des microprogrammes compa-
tibles les plus récents. Pour plus d'informations, visitez le site www.rotronic.com.
Code de
commande
HP31 HP32 HP-GTS
Capteurs
compatibles
Capteur intégré Capteurs HC2 et HC2A-S.
Les capteurs doivent être
commandés séparément.
Capteur intégré
2 APEU DE L’APPAREIL
Veillez à ce que la tête de la che ne soit pas
branchée avec une polarité inversée.
3 FONCTIONNEMENT GÉNÉRAL
3.1 INSTALLATION DU LOGICIEL HW4 LITE
Lanalyse des données et les principaux réglages de l’appareil peuvent être effectués confor-
tablement avec le logiciel gratuit HW4. Téléchargez simplement la version actuelle du logiciel
HW4 depuis la page d’accueil de Rotronic. Le logiciel reste le même, la clé correspondante
permet de débloquer la version souhaitée. La version Lite ne nécessite pas de clé et permet de
connecter jusqu’à trois appareils Rotronic. Les capteurs comptent pour un appareil.
3.2 BATTERIE, VEILLE ET ART AUTOMATIQUE
HP3x est équipé d’une pile intége au lithium. Raccordez simplement l’appareil avec le câble
fourni à un port USB pour le recharger. L’appareil dispose de fonctions de veille et d’arrêt au-
tomatique. An d’économiser la pile, l’écran est éteint après 5 minutes sans intervention de
l’utilisateur et l’appareil est mis hors tension après 10 minutes. Cette fonction n’affecte pas
l’enregistrement des données.
3.3 AFFICHAGE ET ÉCRAN D’ACCUEIL
3.4 RÉINITIALISATION GÉNÉRALE
Dans certains cas, l’appareil de mesure HP3x peut avoir besoin d'être réinitialisé. Il s’agit, entre
autres, des cas suivants :
Rétablissement des réglages d’usine.
HP3x ne fonctionne pas correctement (les valeurs afchées sont bloquées).
Toutes les données utilisateur sont effacées lors de la réinitialisation. Pour effectuer la réini-
tialisation générale : maintenez la touche de réinitialisation, au dos de l’appareil, enfoncée
pendant 3 secondes, à l’aide d'un stylet ou d’un trombone.
4 RÉGLAGES PRINCIPAUX
4.1 LANGUE
Menu principal [OK] glages Langue
Langues disponibles : anglais, allemand, français, italien
4.2 DATE/HEURE
Menu principal [OK] Réglages Date / Heure
En dehors de la date et de l'heure, les réglages suivants peuvent être effectués.
Format de la date : DIN, US, ISO
Format de l’heure : 12h, 24h
Pour un fonctionnement optimal, la date et l’heure doivent être réglées correctement.
Veuillez noter que si la batterie est complètement déchare, le combiné doit être à nouveau
synchronisé avec le logiciel HW4
4.3 UNITÉS
Outre la date et l'heure, les réglages suivants peuvent être effectués.
Les possibilités sont les suivantes :
Distance : m, ft
Température : °C, °F
Pression : hPa, mmHg
Poids : kg, lbs
[ON/OFF] Mise en et hors service du HP32.
Connecteur de raccordement du capteur
Filetage pour trépied
Touche de réinitialisation
Aimant intégré
Fixation de la bandoulière
Raccordement USB
[BAS] Curseur vers le bas
[GAUCHE]
[DROITE]
Touches d'action dont la fonction est indi-
quée par la description sur l'écran.
[HAUT] Curseur vers le haut
Choix des paramètres (écran d’accueil)
Barre d’état
Heure et date
Indicateur de maintien
Indicateur de journal
État de la pile
Valeurs de mesures
Description des touches d’action
[OK] Ouvre le menu principal / sous menu
Conrme les saisies
4.4 PARAMÈTRES PSYCHROMÉTRIQUES CALCULÉS
En plus de l’humidité et de la température, HP32 peut afcher deux des dix paramètres psy-
chrométriques suivants :
Points de rosée/de gel (Dp/Fp)
Température à bulbe humide (Tw)
Enthalpie (H)
Densité de la vapeur deau (Dv)
Humidité spécique (Q)
Poids de rapport de mélange (R)
Pression de la vapeur deau (E)
Pression de saturation de la vapeur (Ew)
Densité de saturation de la vapeur deau (SVD)
Pour le choix des paramètres que vous désirez prendre en protocole et/ou afcher sur l’écran
d’accueil rendez vous sur :
Menu principal [OK] Réglages Paramètres calculés afchés
Vous pouvez modier l'ordre dans lequel les valeurs sont afchées sur l'écran d'accueil
en appuyant sur [HAUT] sur l'écran d'accueil.
Pour modier la constante atmosphérique utilisée pour les calculs rendez vous sur :
Menu principal [OK]  Réglages  Pression atmosphérique
5 STOCKAGE DES DONES
5.1 SAISIE/ENREGISTREMENT ET ENREGISTREMENT PONCTUEL
Les valeurs afchées sur l'écran d'accueil peuvent être bloquées en appuyant sur la touche
d'action [BLOQUER/ENREGISTRER] de l'écran d'accueil. Ces valeurs peuvent alors :
Être enregistrées comme enregistrement ponctuel avec [Saisie]
Être libérées avec [Libérer]
5.2 ENREGISTREMENT DES DONNÉES
Programmez ou démarrez l’enregistrement automatique des données à intervalles guliers
avec la touche d’action [Enregistrer]. Dénissez l’emplacement pour lenregistrement, l’inter-
valle et, si vous le désirez, l’heure de but et de n de l’enregistrement; démarrez alors le
processus d'enregistrement en appuyant sur la touche d'action [marrer].
Votre appareil sera mis en service automatiquement à l’heure désirée pour débuter l’en-
registrement.
L’accès au menu principal est impossible pendant l’enregistrement des données. Les en-
registrements ponctuels peuvent toutefois être effectués.
Le nom de l’emplacement de l’enregistrement doit être déni avant l’utilisation. Utilisez
simplement la touche d’action pour attribuer un nom lors du choix de l’emplacement de
l’enregistrement.
6 AFFICHAGE DES DONNÉES ENREGISTRÉES
6.1 ENREGISTREMENT PONCTUEL
Pour le contrôle de l’enregistrement ponctuel, choisissez l’emplacement de l’enregistre-
ment de la manière suivante :
Menu principal [OK] Enregistrement Saisir
6.2 DONNÉES ENREGISTRÉES
Pour le contrôle des données enregistrées, choisissez l’emplacement de l’enregistre-
ment de la manière suivante :
Menu principal [OK] Enregistrement Enregistrer
Vous pouvez choisir entre l’afchage graphique et les valeurs MIN / MAX / AVG des paramètres
avec [HAUT] et [BAS].Vous pouvez choisir entre l’afchage graphique et les valeurs MIN / MAX /
AVG des 4 paramètres avec [HAUT] et [BAS].
7 ALARME
Pour paramétrer les seuils d’alarme inférieurs et supérieurs, ainsi que l’hystérèse pour chaque
paramètre afché, choisissez :
Menu principal [OK] Alarme
En cas de dépassement, les seuils d’alarme sont afchés en rouge sur l’écran d’accueil.
Vous pouvez également activer une alarme acoustique pour les alarmes :
Menu principal [OK] glages Signal d’alarme
8 AJUSTAGE
Le HP3X dispose d’une fonction d’ajustage de l’humidité et de la température, de sorte que
vous pouvez effectuer l’ajustage directement avec l’appareil de mesure portatif. L’appareil per-
met d’ajuster la température sur 1 point et l’humidité sur 1 ou 3 points.
Menu principal [OK] Ajustage
Sélectionnez à l’aide de la èche « Humidité » ou « Température » et conrmez avec [OK].
Exemple de séquence d’ajustage de l’humidité sur 3 points :
Valeur de référence 1 10 %HR
Valeur de référence 2 35 %HR
Valeur de référence 3 80 %HR
La valeur de référence peut être saisie à l’aide du clavier, le capteur connecté afchant la valeur
de mesure actuelle. Après l’entrée de la première valeur de référence (10 %HR) conrmez en ap-
puyant sur [OK] « Enregistrer et continuer » et entrez la valeur de référence suivante (35 %HR).
Après avoir saisi les trois valeurs de référence, conrmez à nouveau « Enregistrer & continuer »
avec la touche [OK] pour terminer l’ajustage. La dernière date d’ajustage est alors indiquée
sous « Ajustage ».
9 CARACTÉRISTIQUES TECHNIQUES
HP31 HP32 HP-GTS
Capteurs compatibles Fixe Capteurs HC2
et HC2A-S. Les
capteurs doivent
être commandés
séparément.
Fixe
Gamme d’utilisation -10…60 °C | 0…100 %HR (sans condensation)
Gamme d’utilisation du
capteur
-1060 °C Selon le capteur,
p. ex. HC2A-S ±0,8
%HR / ±0,1 °C
-1060 °C
Précision @ 23 °C ±2 %HR / ±0,3 °C ±2 %HR / ±0,3 °C
Fonctions Enregistrement ponctuel / à intervalles
MIN / MAX / AVG / MKT
Intervalle d’enregistrement 1 s…24 h
Mémoire pour les valeurs
de mesure
8 x 8000 points de données
Calculs
psychrométriques
Points de rosée/de gel (Dp/Fp)
Température à bulbe humide (Tw)
Enthalpie (H)
Densité de la vapeur deau (Dv)
Humidité spécique (Q)
Poids de rapport de mélange (R)
Pression de la vapeur deau (E)
Pression de saturation de la vapeur (Ew)
Densité de saturation de la vapeur deau (SVD)
Fréquence de rafraîchisse-
ment de l’écran
1 s (typique)
Pile intégrée 48 h – Enregistrement toutes les 30 s, avec écran éteint
10 h – Avec écran en fonction (typique)
Interface PC Raccordement micro USB, compatible avec HW4
Matériau du boîtier ABS, TPR
Type de protection IP IP65
Dimensions 160 x 63 x 30 mm
Poids 185 g
10 FOURNITURES
HygroPalm HP-31/32/GTS
Sacoche souple
Câble de service (AC0006)
Attache pour ceinture, courroie et certicat
Attache pour ceinture
HP32 avec capteur HC2S-S (non compris dans la livraison)
www.rotronic.comItaliano
12.8000.2505I
HYGROPALM HP31/32/GTS
Manuale di istruzioni breve
1 DESCRIZIONE GENERALE
La serie di strumenti portatili HP3x è potente e multifunzionale, infatti misura, visualizza e
registra temperatura, umidità e parametri calcolati. La serie è composta da tre diversi stru-
menti. Assicurarsi che i dispositivi abbiano il rmware più recente compatibile. Per ulteriori
informazioni visitare il sito www.rotronic.com.
Codice d'ordine HP31 HP32 HP-GTS
Sonde compa-
tibili
Sonda ssa Sonde HC2 e HC2A-S.
Le sonde vanno ordinate
separatamente
Sonda ssa
2 PANORAMICA STRUMENTO
Assicurarsi che la testa del connettore non
sia inserita con polarità invertita.
3 FUNZIONAMENTO GENERALE
3.1 INSTALLAZIONE SOFTWARE HW4 LITE
L'analisi dei dati e l'impostazione generale dello strumento si possono effettuare facilmente
con il software gratuito HW4. Per ottenere il software, scaricare l'ultima versione del software
HW4 dalla homepage di Rotronic. Benché il software sia sempre lo stesso, la chiave corrispon-
dente sblocca la versione desiderata. Per la versione Lite gratuita non serve alcuna chiave ed è
possibile connettere no ad un massimo di 3 strumenti Rotronic. Ogni sonda viene considerata
come uno strumento.
3.2 BATTERIA, STAND-BY E AUTO DISATTIVAZIONE
La serie HP3x presenta una batteria al litio integrata. Basta connettere lo strumento ad una
porta USB con il cavo in dotazione per ricaricarla. Lo strumento dispone di una funzione di
stand-by e di auto disattivazione. Trascorsi 5 minuti senza alcuna interazione da parte dell'u-
tente, si disattiva il display, dopo 10 minuti si disattiva lo strumento, per risparmiare energia
della batteria. Tale funzione non inuisce sull'operatività della registrazione dati.
3.3 SCHERMATA DISPLAY E SCHERMATA INIZIALE
3.4 MASTER RESET
Solo in qualche caso lo strumento HP3x potrebbe necessitare di un reset. Tra questi ricordiamo:
Il ripristino delle impostazioni originali di fabbrica.
Il funzionamento inadeguato della serie HP3x (i valori sono congelati).
L'effettuazione di un reset comporterà la cancellazione dei dati utente. Per effettuare un Master
reset, premere il pulsante di reset posto sul retro dello strumento tenendolo premuto per 3 s
con una penna sottile o una graffetta da ufcio.
4 IMPOSTAZIONI GENERALI
4.1 LINGUA
Menu principale [OK] Impostazioni Lingua
Lingue disponibili: English, Deutsch, Français, Italiano
4.2 DATA/ORA
Menu principale [OK] Impostazioni Data / Ora
Oltre alla data e all'ora, è possibile settare anche le impostazioni seguenti.
Formato data: DIN, US, ISO
Formato ora: 12 h, 24 h
La data e l'ora vanno impostate correttamente, afnché lo strumento funzioni adeguatamente.
Si prega di notare che se la batteria è completamente scarica, il portatile deve essere di nuovo
sincronizzato con il software HW4.
4.3 UNI
Menu principale [OK] Impostazioni Unità
Le opzioni a disposizione sono le seguenti:
Distanza: m, ft
Temperatura: °C, °F
Pressione: hPa, mmHg
Peso: kg, lbs
[TENSIONE DI
ALIMENTAZIONE]
Attiva o disattiva lo strumento HP32.
Connettore sonda
Innesto per cavalletti
Pulsante reset
Magnete integrato
Fissaggio con cordino
Porta USB
[GIÙ] Cursore giù
[SINISTRA]
[DESTRA]
Pulsanti la cui azione viene indicata da
descrizioni sulla schermata.
[SU] Cursore su
Selezione Parametro (schermata iniziale)
Barra di stato
Ora e data
Indicatore di blocco
Indicatore di registrazione
Stato batteria
Valori misurati
Descrizioni pulsanti
[OK] Apre il menu principale / i sottomenu
Conferma le immissioni
4.4 PARAMETRI PSICROMETRICI CALCOLATI
Oltre all'umidità relativa e alla temperatura, il modello HP32 può visualizzare 2 dei 10 parame-
tri psicrometrici seguenti:
Punto di rugiada / Punto di gelo (Dp/Fp)
Temperatura di bulbo umido (Tw)
Entalpia (H)
Concentrazione di vapore (Dv)
Umidità specica (Q)
Rapporto di miscelazione - peso (R)
Pressione di vapore (E)
Pressione del vapore saturo (Ew)
Densità del vapore saturo (SVD)
Selezionare i parametri che si intendono registrare e/o visualizzare nella schermata iniziale
all'interno di:
Menu principale [OK] Impostazioni Parametri calcolati a display
È possibile modicare l'ordine dei valori nella schermata iniziale premendo il pulsante
[SU] nella schermata iniziale.
È possibile modicare la costante di pressione atmosferica usata per i calcoli all'interno di:
Menu principale Impostazioni Pressione atmosferica
5 SALVATAGGIO DATI
5.1 BLOCCA/ACQUISISCI E MISURA PUNTUALE
Congelare i valori a display sulla schermata iniziale premendo il pulsante [Blocca/Acquisisci]
presente nella schermata iniziale. A quel punto i valori potranno essere:
Salvati come misura puntuale con [Acquisisci]
Ricancellati con [Cancella]
5.2 REGISTRAZIONE DATI
Programmare o iniziare la registrazione automatica ad intervalli regolari usando il pulsante
[Registra]. Denire la posizione di salvataggio, l'intervallo e, volendo, un orario di inizio e di
stop, quindi avviare l'operazione di registrazione premendo il pulsante [Avvia].
Il proprio strumento si attiverà automaticamente all'orario di inizio indicato per avviare
la registrazione.
Il menu principale non è accessibile mentre è attiva la registrazione dati. Tuttavia sono
ancora possibili le misure puntuali.
Prima dell'uso occorre denominare la posizione di salvataggio. Basta ricorrere al pulsan-
te [Rinomina] per denominarla, quando si seleziona la posizione di salvataggio.
6 VISUALIZZAZIONE DEI DATI SALVATI
6.1 MISURE PUNTUALI
Per controllare le misure puntuali selezionare la loro posizione di salvataggio all'interno di:
Menu principale [OK] Memoria – Acquisisci
6.2 DATI REGISTRATI
Per controllare i dati registrati selezionare la loro posizione di salvataggio all'interno di:
Menu principale [OK] Memoria – Registra
È possibile muoversi fra le visualizzazioni grache e i valori MIN / MAX / AVG dei 4 parametri
con i pulsanti [SU] e [G].
7 ALLARME
Impostare i limiti di allarme superiore, inferiore e l'isteresi per ogni parametro visualizzato
all'interno di:
Menu principale [OK] Allarmi
I limiti di allarme superati vengono visualizzati in rosso nella schermata iniziale.
È possibile inoltre attivare un segnale acustico per segnalare un allarme:
Menu principale [OK] Impostazioni Buzzer
8 CALIBRAZIONE
La serie HP3X dispone di una funzione di calibrazione dell'umidità e della temperatura, pertan-
to è possibile effettuare la calibrazione direttamente con lo strumento di misura portatile. Lo
strumento è in grado di effettuare calibrazioni su 1 punto per la temperatura e calibrazioni su
1 punto o su 3 punti per l'umidità.
Menu principale [OK] Calibrazione
Esempio di sequenza di calibrazione dell'umidità su 3 punti:
Valore di riferimento 1 10 %UR
Valore di riferimento 2 35 %UR
Valore di riferimento 3 80 %UR
È possibile inserire il valore del riferimento tramite la tastiera, per cui la sonda connessa visua-
lizza il valore di misura effettivo. Dopo l'inserimento del primo valore di riferimento (10 %UR) si
può confermare mediante il tasto OK "Memoria e Avanti", quindi inserire il valore di riferimento
successivo (35 %UR).
Una volta registrati tutti e tre i valori di riferimento, occorrerà confermare con il tasto OK ancora
una volta "Memoria & Avanti", dopodiché la calibrazione sarà conclusa. A questo punto la data
dell'ultima calibrazione comparirà sotto la voce Calibrazione.
9 DATI TECNICI
HP31 HP32 HP-GTS
Sonde compatibili Fissa Sonde HC2 e
HC2A-S. Le sonde
vanno ordinate
separatamente
Fissa
Campo di lavoro -10…60 °C | 0…100 %UR (non cond.)
Campo di lavoro sonda -1060 °C In base alla sonda,
per esempio HC2A-S
±0,8 %UR / ±0,1 °C
-1060 °C
Precisione a 23 °C ±2 %UR / ±0,3 °C ±2 %UR / ±0,3 °C
Funzioni Misurazioni puntuali / Registrazioni ad intervallo
MIN / MAX / AVG / MKT
Intervallo di registrazione 1 s…24 h
Capacità di memoria 8 x 8000 acquisizioni
Calcoli
psicrometrici
Punto di rugiada / Punto di gelo (Dp /Fp)
Temperatura di bulbo umido (Tw)
Entalpia (H)
Concentrazione di vapore (Dv)
Umidità specica (Q)
Rapporto di miscelazione - peso (R)
Pressione di vapore (E)
Pressione del vapore saturo (Ew)
Densità del vapore saturo (SVD)
Frequenza d'aggiornamen-
to display
1 s (tipica)
Batteria integrata 48 h – Registrazioni ogni 30 s, schermata disattivata
10 h – Schermata sempre attiva (tipico)
Interfaccia PC Porta micro-USB, compatibile con HW4
Materiale housing ABS, TPR
Protezione IP IP65
Dimensioni 160 x 63 x 30 mm
Peso 185 g
10 DOTAZIONE
HygroPalm HP-31/32/GTS
Custodia soft case
Cavo di servizio micro-USB (AC0006)
Set bbia per cinghia, cordino e certicato
Set bbia per cinghia
HP32 con sonda HC2S-S (da ordinare separatamente)
www.rotronic.comEspañol
12.8000.2505ES
HYGROPALM HP31/32/GTS
Manual de uso abreviado
1 DESCRIPCIÓN GENERAL
El instrumento de medición portátil de la serie HP3x es un potente instrumento multifunción
que muestra la temperatura, la humedad y los parámetros calculados. La serie se compone de
tres modelos distintos. Asegúrese de que los dispositivos tengan el último rmware compati-
ble. Para obtener más información, visite www.rotronic.com.
Código de pedido HP31 HP32 HP-GTS
Sonda compatible Sonda integrada Sondas HC2 y HC2A-S.
Las sondas deben
pedirse por separado.
Sonda integrada
2 VISTA DEL INNSTRUMENTO
Asegúrate de que la cabeza del enchufe no
esté conectada con la polaridad invertida.
3 FUNCIONAMIENTO GENERAL
3.1 INSTALACN DEL SOFTWARE HW4 LITE
El análisis de datos y los ajustes generales del instrumento se pueden realizar cómodamente
con el software gratuito HW4. Sólo tiene que descargar el software HW4 más actual de la pági-
na web de Rotronic. El software es siempre el mismo, con la llave electrónica correspondiente
se desbloquea la versión deseada. No se requiere ninguna llave para la versión Lite gratuita y
se pueden conectar hasta 3 instrumentos Rotronic. Las sondas cuentan como un solo instru-
mento.
3.2 BATERÍA, MODO DE ESPERA Y DESCONEXN AUTOMÁTICA
El HP3x dispone de una batería de litio integrada. Para cargarlo, simplemente conecte el ins-
trumento a un puerto USB utilizando el cable suministrado. El instrumento dispone de una
función de modo de espera y una función de desconexión automática. Después de un total
de 5 minutos sin intervención del usuario, la pantalla del instrumento se apaga y después de
10 minutos el instrumento para conservar la energía de la batería. Esta función no afecta a la
función de registro de datos.
3.3 PANTALLA Y PANTALLA DE INICIO
3.4 RESTABLECIMIENTO MAESTRO
En algunos casos puede ser necesario reiniciar el instrumento HP3x. Para ello se debe hacer
lo siguiente:
Restablecimiento de los ajustes de fábrica
El HP3x no funciona correctamente (los valores están congelados).
En caso de restablecimiento se borrarán todos los datos. Realizar restablecimiento maestro:
mantenga presionado el botón Reset en la parte posterior del instrumentos con un bolígrafo
no o un clip durante 3 segundos.
4 AJUSTES GENERALES
4.1 IDIOMA
Menú principal [OK] Ajustes Idioma
Idiomas disponibles: inglés, alemán, francés e italiano
4.2 FECHA/HORA
Menú principal [OK] Ajustes Fecha / Hora
Además de la fecha y la hora, se pueden realizar los siguientes ajustes:
Formato de fecha: DIN, US, ISO
Formato de hora: 12 h, 24 h
La fecha y la hora deben estar correctamente ajustadas para que el funcionamiento sea co-
rrecto.
Tenga en cuenta que si la batería está completamente descargada, el dispositivo de mano debe
ser sincronizado de nuevo con el software HW4.
4.3 UNIDADES
Menú principal [OK] Ajustes Unidades
Las opciones son las siguientes:
Distancia: m, ft
Temperatura: °C, °F
Presión: hPa, mmHg
Peso: kg, lbs
Barra de estado
Fecha y hora
Indicador de retención
Indicador de registro
Estado de batería
Valores medidos
Etiquetas de botones de acción
4.4 PARÁMETROS PSICROMÉTRICOS CALCULADOS
Además de la humedad relativa y la temperatura, el HP32 puede mostrar dos de los siguientes
10 parámetros psicrométricos:
Punto de rocío / Punto de escarcha (Dp/Fp)
Temperatura de bulbo húmedo (Tw)
Entalpía (H)
Densidad de vapor de agua (Dv)
Humedad especíca (Q)
Relación de peso-mezcla (R)
Presión de vapor de agua (E)
Presión de vapor de saturación (Ew)
Densidad de saturación de vapor de agua (SVD)
Para la selección de los parámetros que desea registrar y/o mostrar en la pantalla de inicio, vaya a:
Menú principal) [OK] Ajustes Parámetros calculados visualizados
Puede modicar el orden de visualización de los valores en la pantalla de inicio pulsando
el botón [ARRIBA] en la pantalla de inicio.
Para cambiar la constante de presión atmosférica utilizada en los cálculos, vaya a:
Menú principal Ajustes Presión atmosférica
5 GUARDAR DATOS
5.1 CAPTURAR/GUARDAR Y REGISTROS DE PUNTOS
Los valores mostrados en la pantalla de inicio se pueden congelar pulsando el botón de acción
[HOLD/CAPTURE] (RETENER/GUARDAR) en la pantalla de inicio. Estos valores pueden:
Guardarse como registro de puntos con [Capture] (Capturar)
Liberarse de nuevo con [Release] (Liberar)
5.2 REGISTRO DE DATOS
Programe o inicie el registro automático a intervalos regulares con el botón de acción [Log]
(Registrar). Dena la ubicación de memoria, el intervalo y, si lo desea, una hora de inicio y pa-
rada; a continuación, inicie la operación de registro pulsando el botón de acción [Start] (Inicio).
El instrumento se encenderá automáticamente a la hora de inicio preestablecida para
iniciar el registro.
Durante el registro de datos, no podrá accederse al menú principal. No obstante, los
registros de puntos pueden seguir realizándose.
Debe darse nombre a las ubicaciones de memoria antes de su uso. Cuando seleccione
una ubicación de memoria, simplemente utilice el botón de acción [Rename] (Renombrar)
para asignar un nombre.
6 VISUALIZACIÓN DE DATOS GUARDADOS
6.1 REGISTROS DE PUNTOS
Para la comprobación de registros de puntos, seleccione la ubicación de memoria del
siguiente modo:
Main Menu (Menú principal) [OK] Memory (Memoria) – Capture (Capturar)
6.2 DATOS REGISTRADOS
Para la comprobación de los datos memorizados, seleccione la ubicación de memoria
del siguiente modo:
Main Menu (Menú principal) [OK] Memory (Memoria) – Save (Guardar)
Con los botones [ARRIBA] y [ABAJO] se puede conmutar entre las visualizaciones gcas y los
valores MIN / MAX / AVG de los 4 parámetros.
7 ALARMA
Para ajustar los límites inferior y superior de alarma y la histéresis de cada parámetro visuali-
zado, vaya a:
Menú principal [OK] Alarmas
Los límites de alarma sobrepasados se representan en rojo en la pantalla de inicio.
También puede activar una señal acústica para una alarma:
Menú principal [OK] Ajustes Tono de señal
8 AJUSTE
El HP3X dispone de una función de ajuste de la humedad y la temperatura que le permite el
ajuste directamente con el instrumento de medición portátil. El instrumento puede tener un
ajuste de 1 punto para la temperatura y un ajuste de 1 o 3 puntos para la humedad.
Main Menu (Menú principal) [OK] Adjustment (Ajuste)
Ejemplo de secuencia del ajuste de humedad de 3 puntos:
Valor de referencia 1 10 % HR
Valor de referencia 2 35 % HR
Valor de referencia 3 80 % HR
El valor de la referencia se puede introducir mediante el teclado y con la sonda acoplada mos-
trando el valor de medición actual. Después de introducir el primer valor de referencia (10 %
HR), pulse OK para "Guardar y continuar" e introduzca el siguiente valor de referencia (35 % HR).
Una vez introducidos los tres valores de referencia, pulse de nuevo la tecla OK para "Guardar y
continuar" y el ajuste habrá concluido. La última fecha de ajuste se indica ahora en Ajuste.
9 DATOS TÉCNICOS
HP31 HP32 HP-GTS
Sondas compatibles Fijo Sondas HC2 y HC2A-S.
Las sondas deben
pedirse por separado.
Fijo
Rango de utilización -10…60°C | 0…100 %HR (sin cond.)
Rango de utilización de
las sondas
-1060 °C En función de la
sonda, p. ej. HC2A-S
±0,8 %HR / ±0,1 °C
-1060 °C
Precisión @ 23 °C ±2 %HR / ±0,3 °C ±2 %HR / ±0,3 °C
Funciones Registro de puntos / Almacenamiento a intervalos
MIN / MAX / AVG / MKT
Intervalo de registro 1 s…24 h
Memoria de medidas 8 x 8000 puntos de datos
Cálculos psicrométricos Punto de rocío / Punto de escarcha (Dp/Fp)
Temperatura de bulbo húmedo (Tw)
Entalpía (H)
Densidad de vapor de agua (Dv)
Humedad especa (Q)
Relación de peso-mezcla (R)
Presión de vapor de agua (E)
Presión de vapor de saturación (Ew)
Densidad de saturación de vapor de agua (SVD)
Frecuencia de actualización
de pantalla
1 s (típica)
Batería integrada 48 h – Registro cada 30 s, con la pantalla apagada
10 h – Con la pantalla encendida (típica)
Interfaz de PC Conexión micro USB, compatible con HW4
Material de la carcasa ABS, TPR
Tipo de protección IP IP65
Dimensiones 160 x 63 x 30 mm
Peso 185 g
10 SE INCLUYE
HygroPalm HP-31/32/GTS
Softcase
Cable de servicio micro USB (AC0006)
Kit para hebilla de cinturón, cordón para el cuello y certicado
[CORRIENTE] Para encender y apagar el HP32
Conector adaptador para sondas
Rosca de trípode
Botón Reset
Imán integrado
Fijación de cordón para cuello
Conexión USB
[ABAJO] Cursor abajo
[IZQUIERDA]
[DERECHA]
Botón de acción cuya función se indica
mediante la designación en la pantalla.
[ARRIBA] Cursor arriba
Selección de parámetros
(pantalla de inicio)
[OK] Abre menú principal / submenús
Conrma las entradas
Kit para hebilla de cinturón
HP32 con sonda HC2S-S (no incluido en el volumen de suministro)

Transcripción de documentos

HYGROPALM HP31/32/GTS Short Instruction Manual 1 GENERAL DESCRIPTION The HP3x-Series handheld instrument is a power full, multifunctional device which measures, displays and logs temperature, humidity and calculated parameters. The series consist of three different devices. Ensure devices have the latest compatible firmware. For more information visit www.rotronic.com. Order Code HP31 HP32 HP-GTS 3 GENERAL OPERATION 3.1 SOFTWARE HW4 LITE INSTALLATION Data analysis, and general setting of the device can be easily done with the free HW4 Software. To get the software, download the latest HW4 Software from the Rotronic Homepage. While the software always remains the same, the corresponding key unlocks the desired version. For the free Lite version, no key is needed and up to 3 Rotronic devices can be connected. Probes count as one device. 3.2 BATTERY, STAND-BY AND AUTO SWITCH The HP3x has an integrated lithium battery. Simply connect the device to an USB port with the delivered cable to charge it. The device has a stand-by and an auto switch off feature. After 5 minutes without user interaction the display is switched off, after 10 minutes the device is switched off to save battery. This feature does not affect data logging operation. 4.4 CALCULATED PSYCHROMETRIC PARAMETERS Beside relative humidity and temperature, the HP32 can display 2 of the following 10 psychrometric parameters: • Dew / Frost point (Dp/Fp) • Wet bulb temperature (Tw) • Enthalpy (H) • Vapor concentration (Dv) • Specific humidity (Q) • Mixing ration by weight (R) • Vapor pressure (E) • Saturation vapor pressure (Ew) • Saturation vapor density (SVD) 8 ADJUSTMENT The HP3X has a humidity and temperature adjustment function so that you can adjust directly with the handheld instrument. The instrument can make a 1-point adjustment for temperature and a 1-point or 3-point adjustment for humidity. Main Menu [OK]  Adjustment Select Humidity or Temperature with the arrow keys and confirm with OK. Example of sequence for 3-point humidity adjustment: Reference value 1 10 %rh Reference value 2 35 %rh Reference value 3 80 %rh Select the parameters that you want to log and/or see on the home screen within: 3.3 Compatible probes 2 Fixed probe Main menu [OK]  Settings  Displayed calculated parameters DISPLAY AND HOME SCREEN Status Bar • Time and date • Hold indicator • Log indicator • Battery status HC2 and HC2A-S Fixed probe probes. Probes must be ordered separately Measured values Action Buttons labels DEVICE OVERVIEW [POWER] Switches the HP32 on or off. [LEFT] [RIGHT] Action buttons, their action are indicated by the on-screen labels. [UP] • Cursor up • Parameter selection (home screen) [OK] • Opens the main menu / submenus • Confirm entries [DOWN] Cursor down 3.4 MASTER RESET There are a few instances in which the HP3x device may need to be reset. These include the following: • To restore to factory default settings. • The HP3x is not functioning properly (value are frozen). You can change the order of values on the home screen by [UP] on the home screen. You can change the atmospheric pressure constant used in calculations in: Main menu  Settings  Atmospheric pressure 5 SAVING DATA 5.1 HOLD/CAPTURE AND SPOT MEASUREMENTS Freeze the displayed values on the home screen by pressing the [Hold/Capture] action button on the home screen. Those values can then be: • Saved as a spot measurement with [Capture] • Released again with [Release] 5.2 DATA LOGGING Program or start the automatic logging at regular interval with the [Log] action button. Define the storage location, the interval and, if you want, a start and stop time, then start the logging operation by pressing the [Start] action button. Your device will be automatically switched on at the given start time to start the logging. Performing a reset will erase user data. Performing a Master Reset: Press and hold the reset button on the backside of the device with a thin pen or an office clammy for 3 sec. The main menu is not accessible while data logging is active. Spot measurements are, however, still possible. 4 4.1 You must name storage locations before use. Simply use the [Rename] action button when selecting a storage location to assign it a name. GENERAL SETTINGS LANGUAGE The value of the reference can be entered with the keypad. The attached probe shows the current measured value. After entering the first reference value (10 %rh), press OK to confirm “Save & Continue” and enter the next reference value (35 %rh). When all three reference values have been entered, press OK to confirm “Save & Continue” again and adjustment is finished. The last adjustment date is now listed under Adjustment. 9 TECHNICAL DATA Compatible probes Application range Probe application range Accuracy @ 23 °C Functions Logging interval Memory capacity Psychrometric calculations Main menu [OK]  Settings  Language HP32 with HC2S-S probe (order separately) Available languages: English, Deutsch, Français, Italiano 6 VIEWING SAVED DATA 6.1 SPOT MEASUREMENTS Review the spot measurements by selecting their storage location within: 4.2 Main Menu [OK]  Memory – Capture DATE/TIME Main menu [OK]  Settings  Date / Time 6.2 Probe connector Tripod socket The following settings can also be set beside the date and time. • Date format: DIN, US, ISO • Time format: 12 h, 24 h Reset button Integrated magnet Lanyard fixation USB port The date and time must be set correctly for proper operation of the device. Please note that if the battery is completely discharged, the handheld device must be time-chronized again with the HW4. Main Menu [OK]  Memory – Log Switch between graphic displays and MIN / MAX / AVG values of the 4 parameters with [UP] and [DOWN]. 7 ALARM Set up upper, lower limits as well as hysteresis for every displayed parameter in: Main Menu [OK]  Alarms 4.3 Belt Buckle Set LOGGED DATA Review the logged data by selecting its storage location within: Display refresh rate Integrated Battery PC Interface Housing Material IP Protection Dimension Weight HP31 Fixed HP32 HC2 and HC2A-S probes. Probes must be ordered separately -10…60 °C | 0…100 %rh (non-cond.) -10…60 °C Depends on probe for example HC2A-S ±2 %rh / ±0.3 °C ±0.8 %rH / ±0.1 °C Spot measurements / Interval logging MIN / MAX / AVG / MKT 1 s…24 h 8 x 8000 data points Dew / Frost point (Dp /Fp) Wet bulb temperature (Tw) Enthalpy (H) Vapor concentration (Dv) Specific humidity (Q) Mixing ratio by weight (R) Vapor pressure (E) Saturation vapor pressure (Ew) Saturation vapor density (SVD) 1 s (typical) 48 h – Logging every 30 s, screen off 10 h – Screen always on (typical) Micro-USB port, HW4 compatible ABS, TPR IP65 160 x 63 x 30 mm 185 g HP-GTS Fixed -10…60 °C ±2 %rh / ±0.3 °C 10 DELIVERED • HygroPalm HP-31/32/GTS • Soft case • Micro-USB service cable (AC0006) • Belt buckle set, lanyard and certificate UNITS Main menu [OK]  Settings  Units Broken alarm limits are shown in red on the home screen. Your options are as follow: • Distance: m, ft • Temperature: °C, °F • Pressure: hPa, mmHg • Weight: kg, lbs To enable an acoustic signal for an alarm: Main Menu [OK]  Settings  Buzzer 12.8000.2505E Make sure that the plug head is not plugged in with reversed polarity. English www.rotronic.com HYGROPALM HP31/32/GTS Kurzbedienungsanleitung 1 ALLGEMEINE BESCHREIBUNG Das Handmessgerät der Serie HP3x ist ein leistungsfähiges Multifunktionsgerät, das Temperatur, Feuchte und berechnete Parameter anzeigt. Die Serie besteht aus drei verschiedenen Modellen. Stellen Sie sicher, dass die Geräte die aktuellste kompatible Firmware haben. Für weitere Informationen besuchen Sie www.rotronic.com. Bestell-Code HP31 HP32 HP-GTS 3 ALLGEMEINE BEDIENUNG 3.1 INSTALLATION DER SOFTWARE HW4 LITE Datenanalyse und allgemeine Geräteeinstellungen lassen sich bequem mit der kostenfreien HW4-Software vornehmen. Laden Sie sich die aktuelle HW4-Software einfach von der Rotronic-Homepage herunter. Die Software ist immer gleich, mit dem entsprechenden Schlüssel wird die jeweils gewünschte Version entsperrt. Für die kostenlose Lite-Version wird kein Schlüssel benötigt, und es können bis zu 3 Rotronic-Geräte angeschlossen werden. Fühler zählen als ein Gerät. 3.2 BATTERIE, STANDBY UND AUTOMATISCHE ABSCHALTUNG Das HP3x verfügt über eine integrierte Lithium-Batterie. Schliessen Sie das Gerät zum Aufladen einfach mit dem mitgelieferten Kabel an einen USB-Anschluss an. Das Gerät verfügt über eine Standby- und eine automatische Abschaltfunktion. Nach insgesamt 5 Minuten ohne Nutzereingriff wird das Display und nach 10 Minuten wird das Gerät ausgeschaltet, um die Batterie zu schonen. Diese Funktion beeinträchtigt die Datenlogging-Funktion nicht. 4.4 BERECHNETE PSYCHROMETRISCHE PARAMETER Neben relativer Feuchte und Temperatur kann das HP32 zwei der folgenden 10 psychrometrischen Parameter anzeigen: • Tau- / Frostpunkt (Dp/Fp) • Feuchtkugeltemperatur (Tw) • Enthalpie (H) • Wasserdampfdichte (Dv) • Spezifische Feuchte (Q) • Gewichts-Mischungsverhältnis (R) • Wasserdampfdruck (E) • Sättigungsdampfdruck (Ew) • Wasserdampfsättigungsdichte (SVD) Zur Auswahl der Parameter, die Sie protokollieren und/oder auf dem Startbildschirm anzeigen wollen, gehen Sie auf: Hauptmenü [OK]  Einstellungen  Angezeigte berechnete Parameter 3.3 Kompatible Fühler 2 Integrierter Fühler DISPLAY UND STARTBILDSCHIRM Sie können die Anzeigereihenfolge der Werte auf dem Startbildschirm ändern, indem Sie auf dem Startbildschirm [AUF] drücken. Status Bar • Time and date • Hold indicator • Log indicator • Battery status HC2- und HC2A-S-Füh- Integrierter Fühler ler. Die Fühler müssen separat bestellt werden. GERÄTEÜBERSICHT Um die in den Berechnungen verwendete Atmosphärendruckkonstante zu ändern, gehen Sie auf: [STROM] Zum Ein- und Ausschalten des HP32. [LINKS] [RECHTS] Aktionstasten, deren Funktion durch die Bezeichnung auf dem Bildschirm gekennzeichnet ist. [AUF] • Cursor aufwärts • Parameterwahl (Homescreen) [OK] • Öffnet Hauptmenü / Untermenüs • Bestätigt Eingaben [AB] Cursor abwärts TECHNISCHE DATEN 5.2 DATENAUFZEICHNUNG Programmieren oder starten Sie die automatische Aufzeichnung in regelmässigen Abständen mit der Aktionstaste [Aufzeichnen]. Definieren Sie den Speicherort, das Intervall und, falls gewünscht, eine Start- und Stoppzeit; starten Sie dann den Aufzeichnungsvorgang durch Drücken der Aktionstaste [Start]. Funktionen Bei einem Reset werden alle Benutzerdaten gelöscht. Master-Reset durchführen: Die Reset-Taste auf der Geräterückseite mit einem dünnen Stift oder einer Büroklammer 3 Sekunden lang gedrückt halten. Ihr Gerät wird zur vorgegebenen Startzeit automatisch eingeschaltet, um die Aufzeichnung zu starten. 4.2 DATUM/UHRZEIT Speicherorte müssen vor der Benutzung benannt werden. Verwenden Sie bei der Auswahl des Speicherorts einfach die Aktionstaste [Umbenennen], um einen Namen zuzuweisen. 6 6.1 Hauptmenü [OK]  Einstellungen  Datum / Zeit ANZEIGE GESPEICHERTER DATEN PUNKTAUFZEICHNUNGEN Zur Prüfung von Punktaufzeichnungen den Speicherort wie folgt auswählen: Hauptmenü [OK]  Speicher – Erfassen Neben Datum und Uhrzeit können folgende Einstellungen vorgenommen werden. • Datumsformat: DIN, US, ISO • Zeitformat: 12 h, 24 h 6.2 AUFGEZEICHNETE DATEN Zur Prüfung der gespeicherten Daten den Speicherort wie folgt auswählen: Hauptmenü [OK]  Speicher – Speichern Für eine einwandfreie Funktion müssen Datum und Uhrzeit richtig eingestellt sein. Bitte beachten Sie, dass bei vollständig entladener Batterie das Handgerät erneut mit der HW4-Software zeitchronisiert werden muss. 4.3 EINHEITEN Hauptmenü [OK]  Einstellungen  Einheiten Einsatzbereich Fühler-Einsatzbereich Genauigkeit @ 23 °C Log-Intervall Messwertspeicher Psychrometrische Berechnungen Während der Datenaufzeichnung kann nicht auf das Hauptmenü zugegriffen werden. Punktaufzeichnungen können jedoch weiterhin gemacht werden. ALLGEMEINE EINSTELLUNGEN SPRACHE Umhängeband-Befestigung USB-Anschluss Nachdem alle drei Referenzwerte eingetragen sind, nochmals «Speichern und Weiter» mit der Taste Ok bestätigen und die Justierung ist abgeschlossen. Das letzte Justierdatum wird nun unter Justierung aufgeführt. 3.4 MASTER-RESET In einigen Fällen muss das HP3x-Gerät gegebenenfalls zurückgesetzt werden. Dazu gehören folgende: • Wiederherstellung der Werkseinstellungen. • Das HP3x funktioniert nicht ordnungsgemäss (Werte sind eingefroren). Verfügbare Sprachen: English, Deutsch, Français, Italiano Integrierter Magnet Der Wert der Referenz kann mittels Tastatur eingegeben werden, wobei der angehängte Fühler den aktuellen Messwert anzeigt. Nach Eingabe des ersten Referenzwertes (10 %rF) kann mit der Taste OK «Speichern & Weiter» bestätigt werden und der nächste Referenzwert (35 %rF) eingegeben werden. Kompatible Fühler Hauptmenü [OK]  Einstellungen  Sprache Reset-Taste Beispiel Reihenfolge 3-Punkte Feuchte Justage: Referenzwert 1 10 %rF Referenzwert 2 35 %rF Referenzwert 3 80 %rF 9 HP32 mit HC2S-S-Fühler (nicht im Lieferumfang enthalten) Stativgewinde Wählen Sie mit den Pfeil Tasten Feuchte oder Temperatur aus und bestätigen mit OK. 5 DATENSPEICHERUNG 5.1 ERFASSEN/SPEICHERN UND PUNKTAUFZEICHNUNGEN Die auf dem Startbildschirm angezeigten Werte können mittels Betätigung der Aktionstaste [HALTEN/SPEICHERN] auf dem Startbildschirm eingefroren werden. Diese Werte können dann: • Als Punktaufzeichnung mit [Erfassen] gespeichert werden • Mit [Lösen] wieder losgelassen werden 4 4.1 Fühler-Anschlussstecker Hauptmenü [OK]  Justierung Hauptmenü  Einstellungen  Atmosphärendruck Measured values Action Buttons labels 8 JUSTIERUNG Das HP3X verfügt über eine Feuchte- und Temperatur Justage Funktion, sodass Sie direkt mit dem Handmessgerät justieren können. Das Gerät kann eine 1-Punkt Justage für die Temperatur und eine 1-Punkt oder 3-Punkte Justage für die Feuchtigkeit. Sie können zwischen den grafischen Anzeigen und den MIN / MAX / AVG-Werten der 4 Parameter mit [AUF] und [AB] umschalten. Display-Wiederholrate Integrierte Batterie PC-Schnittstelle Gehäusematerial IP-Schutzart Abmessungen Gewicht HP31 Fix HP32 HP-GTS HC2- und HC2A-S- Fix Fühler. Die Fühler müssen separat bestellt werden. -10…60 °C | 0…100 %rF (nicht kond.) -10…60 °C Abhängig vom -10…60 °C Fühler, z. B. HC2A-S ±2 %rF / ±0,3 °C ±2 %rF / ±0,3 °C ±0,8 %rF / ±0,1 °C Punktaufzeichnung / Intervallspeicherung MIN / MAX / AVG / MKT 1 s…24 h 8 x 8000 Datenpunkte Tau- / Frostpunkt (Dp/Fp) Feuchtkugeltemperatur (Tw) Enthalpie (H) Wasserdampfdichte (Dv) Spezifische Feuchte (Q) Gewichts-Mischungsverhältnis (R) Wasserdampfdruck (E) Sättigungsdampfdruck (Ew) Wasserdampfsättigungsdichte (SVD) 1 s (typisch) 48 h – Aufzeichnung alle 30 s, bei ausgeschaltetem Bildschirm 10 h – Bei eingeschaltetem Bildschirm (typisch) USB-Micro-Anschluss, HW4-kompatibel ABS, TPR IP65 160 x 63 x 30 mm 185 g 10 LIEFERUMFANG • HygroPalm HP-31/32/GTS • Softcase • Micro-USB-Servicekabel (AC0006) • Gürtelschnallen-Set, Umhängeband und Zertifikat 7 ALARM Zur Einrichtung der unteren und oberen Alarmgrenze sowie der Hysterese für jeden angezeigten Parameter, gehen Sie auf: Hauptmenü [OK]  Alarme Gürtelschnallen-Set Überschrittene Alarmgrenzen werden auf dem Startbildschirm rot dargestellt. Sie können zudem ein akustisches Signal für einen Alarm aktivieren: Hauptmenü [OK]  Einstellungen  Warnsignal 12.8000.2505D Stellen Sie sicher, dass der Steckerkopf nicht mit verkehrter Polarität eingesteckt ist. Die Auswahlmöglichkeiten sind: • Distanz: m, ft • Temperatur: °C, °F • Druck: hPa, mmHg • Gewicht: kg, lbs Deutsch www.rotronic.com Manuel abrégé 1 DESCRIPTION GÉNÉRALE L’instrument de mesure portatif de la série HP3x est un appareil multifonction puissant qui affiche la température, l’humidité et calcule divers paramètres. La série est composée de trois modèles différents. Veillez à ce que les appareils soient dotés des microprogrammes compatibles les plus récents. Pour plus d'informations, visitez le site www.rotronic.com. Code de commande HP31 HP32 HP-GTS 3 FONCTIONNEMENT GÉNÉRAL 3.1 INSTALLATION DU LOGICIEL HW4 LITE L’analyse des données et les principaux réglages de l’appareil peuvent être effectués confortablement avec le logiciel gratuit HW4. Téléchargez simplement la version actuelle du logiciel HW4 depuis la page d’accueil de Rotronic. Le logiciel reste le même, la clé correspondante permet de débloquer la version souhaitée. La version Lite ne nécessite pas de clé et permet de connecter jusqu’à trois appareils Rotronic. Les capteurs comptent pour un appareil. 3.2 BATTERIE, VEILLE ET ARRÊT AUTOMATIQUE HP3x est équipé d’une pile intégrée au lithium. Raccordez simplement l’appareil avec le câble fourni à un port USB pour le recharger. L’appareil dispose de fonctions de veille et d’arrêt automatique. Afin d’économiser la pile, l’écran est éteint après 5 minutes sans intervention de l’utilisateur et l’appareil est mis hors tension après 10 minutes. Cette fonction n’affecte pas l’enregistrement des données. 3.3 Capteurs compatibles 2 Capteur intégré Capteurs HC2 et HC2A-S. Les capteurs doivent être commandés séparément. Barre d’état • Heure et date • Indicateur de maintien • Indicateur de journal • État de la pile Vous pouvez modifier l'ordre dans lequel les valeurs sont affichées sur l'écran d'accueil en appuyant sur [HAUT] sur l'écran d'accueil. Valeurs de mesures Menu principal [OK]  Réglages  Pression atmosphérique Description des touches d’action APERÇU DE L’APPAREIL [ON/OFF] Mise en et hors service du HP32. [GAUCHE] [DROITE] Touches d'action dont la fonction est indiquée par la description sur l'écran. [HAUT] • Curseur vers le haut • Choix des paramètres (écran d’accueil) [OK] • Ouvre le menu principal / sous menu • Confirme les saisies [BAS] Curseur vers le bas Pour le choix des paramètres que vous désirez prendre en protocole et/ou afficher sur l’écran d’accueil rendez vous sur : Menu principal [OK]  Réglages  Paramètres calculés affichés AFFICHAGE ET ÉCRAN D’ACCUEIL Capteur intégré 4.4 PARAMÈTRES PSYCHROMÉTRIQUES CALCULÉS En plus de l’humidité et de la température, HP32 peut afficher deux des dix paramètres psychrométriques suivants : • Points de rosée/de gel (Dp/Fp) • Température à bulbe humide (Tw) • Enthalpie (H) • Densité de la vapeur d’eau (Dv) • Humidité spécifique (Q) • Poids de rapport de mélange (R) • Pression de la vapeur d’eau (E) • Pression de saturation de la vapeur (Ew) • Densité de saturation de la vapeur d’eau (SVD) Pour modifier la constante atmosphérique utilisée pour les calculs rendez vous sur : 5.2 ENREGISTREMENT DES DONNÉES Programmez ou démarrez l’enregistrement automatique des données à intervalles réguliers avec la touche d’action [Enregistrer]. Définissez l’emplacement pour l’enregistrement, l’intervalle et, si vous le désirez, l’heure de début et de fin de l’enregistrement; démarrez alors le processus d'enregistrement en appuyant sur la touche d'action [Démarrer]. Toutes les données utilisateur sont effacées lors de la réinitialisation. Pour effectuer la réinitialisation générale : maintenez la touche de réinitialisation, au dos de l’appareil, enfoncée pendant 3 secondes, à l’aide d'un stylet ou d’un trombone. Votre appareil sera mis en service automatiquement à l’heure désirée pour débuter l’enregistrement. L’accès au menu principal est impossible pendant l’enregistrement des données. Les enregistrements ponctuels peuvent toutefois être effectués. RÉGLAGES PRINCIPAUX LANGUE Menu principal [OK]  Réglages  Langue Le nom de l’emplacement de l’enregistrement doit être défini avant l’utilisation. Utilisez simplement la touche d’action pour attribuer un nom lors du choix de l’emplacement de l’enregistrement. Langues disponibles : anglais, allemand, français, italien HP32 avec capteur HC2S-S (non compris dans la livraison) 4.2 Connecteur de raccordement du capteur Filetage pour trépied Touche de réinitialisation DATE/HEURE Menu principal [OK]  Réglages  Date / Heure Fixation de la bandoulière Raccordement USB Veuillez noter que si la batterie est complètement déchargée, le combiné doit être à nouveau synchronisé avec le logiciel HW4 UNITÉS Outre la date et l'heure, les réglages suivants peuvent être effectués. Veillez à ce que la tête de la fiche ne soit pas branchée avec une polarité inversée. Les possibilités sont les suivantes : • Distance : m, ft • Température : °C, °F • Pression : hPa, mmHg • Poids : kg, lbs AFFICHAGE DES DONNÉES ENREGISTRÉES ENREGISTREMENT PONCTUEL Pour le contrôle de l’enregistrement ponctuel, choisissez l’emplacement de l’enregistrement de la manière suivante : Menu principal [OK]  Enregistrement  Saisir 6.2 Pour un fonctionnement optimal, la date et l’heure doivent être réglées correctement. 4.3 Attache pour ceinture 6 6.1 En dehors de la date et de l'heure, les réglages suivants peuvent être effectués. • Format de la date : DIN, US, ISO • Format de l’heure : 12h, 24h Aimant intégré DONNÉES ENREGISTRÉES Pour le contrôle des données enregistrées, choisissez l’emplacement de l’enregistrement de la manière suivante : Menu principal [OK]  Enregistrement  Enregistrer Vous pouvez choisir entre l’affichage graphique et les valeurs MIN / MAX / AVG des paramètres avec [HAUT] et [BAS].Vous pouvez choisir entre l’affichage graphique et les valeurs MIN / MAX / AVG des 4 paramètres avec [HAUT] et [BAS]. Sélectionnez à l’aide de la flèche « Humidité » ou « Température » et confirmez avec [OK]. Exemple de séquence d’ajustage de l’humidité sur 3 points : Valeur de référence 1 10 %HR Valeur de référence 2 35 %HR Valeur de référence 3 80 %HR La valeur de référence peut être saisie à l’aide du clavier, le capteur connecté affichant la valeur de mesure actuelle. Après l’entrée de la première valeur de référence (10 %HR) confirmez en appuyant sur [OK] « Enregistrer et continuer » et entrez la valeur de référence suivante (35 %HR). Après avoir saisi les trois valeurs de référence, confirmez à nouveau « Enregistrer & continuer » avec la touche [OK] pour terminer l’ajustage. La dernière date d’ajustage est alors indiquée sous « Ajustage ». CARACTÉRISTIQUES TECHNIQUES HP32 HP-GTS Capteurs HC2 Fixe et HC2A-S. Les capteurs doivent être commandés séparément. Gamme d’utilisation -10…60 °C | 0…100 %HR (sans condensation) Gamme d’utilisation du -10…60 °C Selon le capteur, -10…60 °C capteur p. ex. HC2A-S ±0,8 %HR / ±0,1 °C Précision @ 23 °C ±2 %HR / ±0,3 °C ±2 %HR / ±0,3 °C Fonctions Enregistrement ponctuel / à intervalles MIN / MAX / AVG / MKT Intervalle d’enregistrement 1 s…24 h Mémoire pour les valeurs 8 x 8000 points de données de mesure Calculs Points de rosée/de gel (Dp/Fp) psychrométriques Température à bulbe humide (Tw) Enthalpie (H) Densité de la vapeur d’eau (Dv) Humidité spécifique (Q) Poids de rapport de mélange (R) Pression de la vapeur d’eau (E) Pression de saturation de la vapeur (Ew) Densité de saturation de la vapeur d’eau (SVD) Fréquence de rafraîchisse- 1 s (typique) ment de l’écran Pile intégrée 48 h – Enregistrement toutes les 30 s, avec écran éteint 10 h – Avec écran en fonction (typique) Interface PC Raccordement micro USB, compatible avec HW4 Matériau du boîtier ABS, TPR Type de protection IP IP65 Dimensions 160 x 63 x 30 mm Poids 185 g Capteurs compatibles HP31 Fixe 10 FOURNITURES • HygroPalm HP-31/32/GTS • Sacoche souple • Câble de service (AC0006) • Attache pour ceinture, courroie et certificat 7 ALARME Pour paramétrer les seuils d’alarme inférieurs et supérieurs, ainsi que l’hystérèse pour chaque paramètre affiché, choisissez : Menu principal [OK]  Alarme En cas de dépassement, les seuils d’alarme sont affichés en rouge sur l’écran d’accueil. Vous pouvez également activer une alarme acoustique pour les alarmes : Menu principal [OK]  Réglages  Signal d’alarme Français Menu principal [OK]  Ajustage 9 5 STOCKAGE DES DONNÉES 5.1 SAISIE/ENREGISTREMENT ET ENREGISTREMENT PONCTUEL Les valeurs affichées sur l'écran d'accueil peuvent être bloquées en appuyant sur la touche d'action [BLOQUER/ENREGISTRER] de l'écran d'accueil. Ces valeurs peuvent alors : • Être enregistrées comme enregistrement ponctuel avec [Saisie] • Être libérées avec [Libérer] 3.4 RÉINITIALISATION GÉNÉRALE Dans certains cas, l’appareil de mesure HP3x peut avoir besoin d'être réinitialisé. Il s’agit, entre autres, des cas suivants : • Rétablissement des réglages d’usine. • HP3x ne fonctionne pas correctement (les valeurs affichées sont bloquées). 4 4.1 8 AJUSTAGE Le HP3X dispose d’une fonction d’ajustage de l’humidité et de la température, de sorte que vous pouvez effectuer l’ajustage directement avec l’appareil de mesure portatif. L’appareil permet d’ajuster la température sur 1 point et l’humidité sur 1 ou 3 points. 12.8000.2505F HYGROPALM HP31/32/GTS www.rotronic.com HYGROPALM HP31/32/GTS Manuale di istruzioni breve 1 DESCRIZIONE GENERALE La serie di strumenti portatili HP3x è potente e multifunzionale, infatti misura, visualizza e registra temperatura, umidità e parametri calcolati. La serie è composta da tre diversi strumenti. Assicurarsi che i dispositivi abbiano il firmware più recente compatibile. Per ulteriori informazioni visitare il sito www.rotronic.com. Codice d'ordine HP31 HP32 HP-GTS 3 FUNZIONAMENTO GENERALE 3.1 INSTALLAZIONE SOFTWARE HW4 LITE L'analisi dei dati e l'impostazione generale dello strumento si possono effettuare facilmente con il software gratuito HW4. Per ottenere il software, scaricare l'ultima versione del software HW4 dalla homepage di Rotronic. Benché il software sia sempre lo stesso, la chiave corrispondente sblocca la versione desiderata. Per la versione Lite gratuita non serve alcuna chiave ed è possibile connettere fino ad un massimo di 3 strumenti Rotronic. Ogni sonda viene considerata come uno strumento. 3.2 BATTERIA, STAND-BY E AUTO DISATTIVAZIONE La serie HP3x presenta una batteria al litio integrata. Basta connettere lo strumento ad una porta USB con il cavo in dotazione per ricaricarla. Lo strumento dispone di una funzione di stand-by e di auto disattivazione. Trascorsi 5 minuti senza alcuna interazione da parte dell'utente, si disattiva il display, dopo 10 minuti si disattiva lo strumento, per risparmiare energia della batteria. Tale funzione non influisce sull'operatività della registrazione dati. 4.4 PARAMETRI PSICROMETRICI CALCOLATI Oltre all'umidità relativa e alla temperatura, il modello HP32 può visualizzare 2 dei 10 parametri psicrometrici seguenti: • Punto di rugiada / Punto di gelo (Dp/Fp) • Temperatura di bulbo umido (Tw) • Entalpia (H) • Concentrazione di vapore (Dv) • Umidità specifica (Q) • Rapporto di miscelazione - peso (R) • Pressione di vapore (E) • Pressione del vapore saturo (Ew) • Densità del vapore saturo (SVD) Selezionare i parametri che si intendono registrare e/o visualizzare nella schermata iniziale all'interno di: Menu principale [OK]  Impostazioni  Parametri calcolati a display 3.3 Sonde compatibili 2 Sonda fissa SCHERMATA DISPLAY E SCHERMATA INIZIALE Sonde HC2 e HC2A-S. Sonda fissa Le sonde vanno ordinate separatamente Valori misurati PANORAMICA STRUMENTO Descrizioni pulsanti [TENSIONE DI Attiva o disattiva lo strumento HP32. ALIMENTAZIONE] [SINISTRA] [DESTRA] Pulsanti la cui azione viene indicata da descrizioni sulla schermata. [SU] • Cursore su • Selezione Parametro (schermata iniziale) [OK] • Apre il menu principale / i sottomenu • Conferma le immissioni [GIÙ] Cursore giù È possibile modificare l'ordine dei valori nella schermata iniziale premendo il pulsante [SU] nella schermata iniziale. Barra di stato • Ora e data • Indicatore di blocco • Indicatore di registrazione • Stato batteria 3.4 MASTER RESET Solo in qualche caso lo strumento HP3x potrebbe necessitare di un reset. Tra questi ricordiamo: • Il ripristino delle impostazioni originali di fabbrica. • Il funzionamento inadeguato della serie HP3x (i valori sono congelati). È possibile modificare la costante di pressione atmosferica usata per i calcoli all'interno di: 5.2 REGISTRAZIONE DATI Programmare o iniziare la registrazione automatica ad intervalli regolari usando il pulsante [Registra]. Definire la posizione di salvataggio, l'intervallo e, volendo, un orario di inizio e di stop, quindi avviare l'operazione di registrazione premendo il pulsante [Avvia]. Il proprio strumento si attiverà automaticamente all'orario di inizio indicato per avviare la registrazione. Il menu principale non è accessibile mentre è attiva la registrazione dati. Tuttavia sono ancora possibili le misure puntuali. Prima dell'uso occorre denominare la posizione di salvataggio. Basta ricorrere al pulsante [Rinomina] per denominarla, quando si seleziona la posizione di salvataggio. Menu principale [OK]  Impostazioni  Lingua Lingue disponibili: English, Deutsch, Français, Italiano 4.2 Connettore sonda Innesto per cavalletti Menu principale [OK]  Memoria – Acquisisci Fissaggio con cordino La data e l'ora vanno impostate correttamente, affinché lo strumento funzioni adeguatamente. Porta USB È possibile muoversi fra le visualizzazioni grafiche e i valori MIN / MAX / AVG dei 4 parametri con i pulsanti [SU] e [GIÙ]. Si prega di notare che se la batteria è completamente scarica, il portatile deve essere di nuovo sincronizzato con il software HW4. 4.3 UNITÀ È possibile inserire il valore del riferimento tramite la tastiera, per cui la sonda connessa visualizza il valore di misura effettivo. Dopo l'inserimento del primo valore di riferimento (10 %UR) si può confermare mediante il tasto OK "Memoria e Avanti", quindi inserire il valore di riferimento successivo (35 %UR). Una volta registrati tutti e tre i valori di riferimento, occorrerà confermare con il tasto OK ancora una volta "Memoria & Avanti", dopodiché la calibrazione sarà conclusa. A questo punto la data dell'ultima calibrazione comparirà sotto la voce Calibrazione. DATI REGISTRATI Per controllare i dati registrati selezionare la loro posizione di salvataggio all'interno di: Menu principale [OK]  Memoria – Registra 7 ALLARME Impostare i limiti di allarme superiore, inferiore e l'isteresi per ogni parametro visualizzato all'interno di: Menu principale [OK]  Impostazioni  Unità Menu principale [OK]  Allarmi Le opzioni a disposizione sono le seguenti: • Distanza: m, ft • Temperatura: °C, °F • Pressione: hPa, mmHg • Peso: kg, lbs I limiti di allarme superati vengono visualizzati in rosso nella schermata iniziale. DATI TECNICI HP32 HP-GTS Sonde HC2 e Fissa HC2A-S. Le sonde vanno ordinate separatamente Campo di lavoro -10…60 °C | 0…100 %UR (non cond.) Campo di lavoro sonda -10…60 °C In base alla sonda, -10…60 °C per esempio HC2A-S ±2 %UR / ±0,3 °C Precisione a 23 °C ±2 %UR / ±0,3 °C ±0,8 %UR / ±0,1 °C Funzioni Misurazioni puntuali / Registrazioni ad intervallo MIN / MAX / AVG / MKT Intervallo di registrazione 1 s…24 h Capacità di memoria 8 x 8000 acquisizioni Calcoli Punto di rugiada / Punto di gelo (Dp /Fp) psicrometrici Temperatura di bulbo umido (Tw) Entalpia (H) Concentrazione di vapore (Dv) Umidità specifica (Q) Rapporto di miscelazione - peso (R) Pressione di vapore (E) Pressione del vapore saturo (Ew) Densità del vapore saturo (SVD) Frequenza d'aggiornamen- 1 s (tipica) to display Batteria integrata 48 h – Registrazioni ogni 30 s, schermata disattivata 10 h – Schermata sempre attiva (tipico) Interfaccia PC Porta micro-USB, compatibile con HW4 Materiale housing ABS, TPR Protezione IP IP65 Dimensioni 160 x 63 x 30 mm Peso 185 g Sonde compatibili HP31 Fissa 10 DOTAZIONE • HygroPalm HP-31/32/GTS • Custodia soft case • Cavo di servizio micro-USB (AC0006) • Set fibbia per cinghia, cordino e certificato È possibile inoltre attivare un segnale acustico per segnalare un allarme: Menu principale [OK]  Impostazioni  Buzzer 12.8000.2505I Assicurarsi che la testa del connettore non sia inserita con polarità invertita. DATA/ORA Menu principale [OK]  Impostazioni  Data / Ora VISUALIZZAZIONE DEI DATI SALVATI MISURE PUNTUALI Per controllare le misure puntuali selezionare la loro posizione di salvataggio all'interno di: 6.2 Magnete integrato Set fibbia per cinghia 6 6.1 Oltre alla data e all'ora, è possibile settare anche le impostazioni seguenti. • Formato data: DIN, US, ISO • Formato ora: 12 h, 24 h Pulsante reset Esempio di sequenza di calibrazione dell'umidità su 3 punti: Valore di riferimento 1 10 %UR Valore di riferimento 2 35 %UR Valore di riferimento 3 80 %UR 9 5 SALVATAGGIO DATI 5.1 BLOCCA/ACQUISISCI E MISURA PUNTUALE Congelare i valori a display sulla schermata iniziale premendo il pulsante [Blocca/Acquisisci] presente nella schermata iniziale. A quel punto i valori potranno essere: • Salvati come misura puntuale con [Acquisisci] • Ricancellati con [Cancella] IMPOSTAZIONI GENERALI LINGUA HP32 con sonda HC2S-S (da ordinare separatamente) Menu principale [OK]  Calibrazione Menu principale  Impostazioni  Pressione atmosferica L'effettuazione di un reset comporterà la cancellazione dei dati utente. Per effettuare un Master reset, premere il pulsante di reset posto sul retro dello strumento tenendolo premuto per 3 s con una penna sottile o una graffetta da ufficio. 4 4.1 8 CALIBRAZIONE La serie HP3X dispone di una funzione di calibrazione dell'umidità e della temperatura, pertanto è possibile effettuare la calibrazione direttamente con lo strumento di misura portatile. Lo strumento è in grado di effettuare calibrazioni su 1 punto per la temperatura e calibrazioni su 1 punto o su 3 punti per l'umidità. Italiano www.rotronic.com HYGROPALM HP31/32/GTS Manual de uso abreviado 1 DESCRIPCIÓN GENERAL El instrumento de medición portátil de la serie HP3x es un potente instrumento multifunción que muestra la temperatura, la humedad y los parámetros calculados. La serie se compone de tres modelos distintos. Asegúrese de que los dispositivos tengan el último firmware compatible. Para obtener más información, visite www.rotronic.com. Código de pedido HP31 HP32 HP-GTS 3 FUNCIONAMIENTO GENERAL 3.1 INSTALACIÓN DEL SOFTWARE HW4 LITE El análisis de datos y los ajustes generales del instrumento se pueden realizar cómodamente con el software gratuito HW4. Sólo tiene que descargar el software HW4 más actual de la página web de Rotronic. El software es siempre el mismo, con la llave electrónica correspondiente se desbloquea la versión deseada. No se requiere ninguna llave para la versión Lite gratuita y se pueden conectar hasta 3 instrumentos Rotronic. Las sondas cuentan como un solo instrumento. 3.2 BATERÍA, MODO DE ESPERA Y DESCONEXIÓN AUTOMÁTICA El HP3x dispone de una batería de litio integrada. Para cargarlo, simplemente conecte el instrumento a un puerto USB utilizando el cable suministrado. El instrumento dispone de una función de modo de espera y una función de desconexión automática. Después de un total de 5 minutos sin intervención del usuario, la pantalla del instrumento se apaga y después de 10 minutos el instrumento para conservar la energía de la batería. Esta función no afecta a la función de registro de datos. 3.3 Sonda compatible Sonda integrada 2 Barra de estado • Fecha y hora • Indicador de retención • Indicador de registro • Estado de batería VISTA DEL INNSTRUMENTO Valores medidos Etiquetas de botones de acción [CORRIENTE] Para encender y apagar el HP32 [IZQUIERDA] Botón de acción cuya función se indica [DERECHA] mediante la designación en la pantalla. • Cursor arriba • Selección de parámetros (pantalla de inicio) [OK] • Abre menú principal / submenús • Confirma las entradas [ABAJO] Cursor abajo Para la selección de los parámetros que desea registrar y/o mostrar en la pantalla de inicio, vaya a: Menú principal) [OK]  Ajustes  Parámetros calculados visualizados PANTALLA Y PANTALLA DE INICIO Sondas HC2 y HC2A-S. Sonda integrada Las sondas deben pedirse por separado. [ARRIBA] 4.4 PARÁMETROS PSICROMÉTRICOS CALCULADOS Además de la humedad relativa y la temperatura, el HP32 puede mostrar dos de los siguientes 10 parámetros psicrométricos: • Punto de rocío / Punto de escarcha (Dp/Fp) • Temperatura de bulbo húmedo (Tw) • Entalpía (H) • Densidad de vapor de agua (Dv) • Humedad específica (Q) • Relación de peso-mezcla (R) • Presión de vapor de agua (E) • Presión de vapor de saturación (Ew) • Densidad de saturación de vapor de agua (SVD) 3.4 RESTABLECIMIENTO MAESTRO En algunos casos puede ser necesario reiniciar el instrumento HP3x. Para ello se debe hacer lo siguiente: • Restablecimiento de los ajustes de fábrica • El HP3x no funciona correctamente (los valores están congelados). HP32 con sonda HC2S-S (no incluido en el volumen de suministro) Fijación de cordón para cuello Conexión USB 9 Durante el registro de datos, no podrá accederse al menú principal. No obstante, los registros de puntos pueden seguir realizándose. Debe darse nombre a las ubicaciones de memoria antes de su uso. Cuando seleccione una ubicación de memoria, simplemente utilice el botón de acción [Rename] (Renombrar) para asignar un nombre. 6 6.1 VISUALIZACIÓN DE DATOS GUARDADOS REGISTROS DE PUNTOS Para la comprobación de registros de puntos, seleccione la ubicación de memoria del siguiente modo: Main Menu (Menú principal) [OK]  Memory (Memoria) – Capture (Capturar) FECHA/HORA Menú principal [OK]  Ajustes  Fecha / Hora 6.2 Botón Reset Imán integrado Para cambiar la constante de presión atmosférica utilizada en los cálculos, vaya a: El instrumento se encenderá automáticamente a la hora de inicio preestablecida para iniciar el registro. Idiomas disponibles: inglés, alemán, francés e italiano 4.2 Además de la fecha y la hora, se pueden realizar los siguientes ajustes: • Formato de fecha: DIN, US, ISO • Formato de hora: 12 h, 24 h DATOS REGISTRADOS Para la comprobación de los datos memorizados, seleccione la ubicación de memoria del siguiente modo: Main Menu (Menú principal) [OK]  Memory (Memoria) – Save (Guardar) La fecha y la hora deben estar correctamente ajustadas para que el funcionamiento sea correcto. Con los botones [ARRIBA] y [ABAJO] se puede conmutar entre las visualizaciones gráficas y los valores MIN / MAX / AVG de los 4 parámetros. Tenga en cuenta que si la batería está completamente descargada, el dispositivo de mano debe ser sincronizado de nuevo con el software HW4. 7 ALARMA Para ajustar los límites inferior y superior de alarma y la histéresis de cada parámetro visualizado, vaya a: 4.3 Menú principal [OK]  Alarmas UNIDADES El valor de la referencia se puede introducir mediante el teclado y con la sonda acoplada mostrando el valor de medición actual. Después de introducir el primer valor de referencia (10 % HR), pulse OK para "Guardar y continuar" e introduzca el siguiente valor de referencia (35 % HR). Una vez introducidos los tres valores de referencia, pulse de nuevo la tecla OK para "Guardar y continuar" y el ajuste habrá concluido. La última fecha de ajuste se indica ahora en Ajuste. 5.2 REGISTRO DE DATOS Programe o inicie el registro automático a intervalos regulares con el botón de acción [Log] (Registrar). Defina la ubicación de memoria, el intervalo y, si lo desea, una hora de inicio y parada; a continuación, inicie la operación de registro pulsando el botón de acción [Start] (Inicio). Conector adaptador para sondas Rosca de trípode Ejemplo de secuencia del ajuste de humedad de 3 puntos: Valor de referencia 1 10 % HR Valor de referencia 2 35 % HR Valor de referencia 3 80 % HR Puede modificar el orden de visualización de los valores en la pantalla de inicio pulsando el botón [ARRIBA] en la pantalla de inicio. 5 GUARDAR DATOS 5.1 CAPTURAR/GUARDAR Y REGISTROS DE PUNTOS Los valores mostrados en la pantalla de inicio se pueden congelar pulsando el botón de acción [HOLD/CAPTURE] (RETENER/GUARDAR) en la pantalla de inicio. Estos valores pueden: • Guardarse como registro de puntos con [Capture] (Capturar) • Liberarse de nuevo con [Release] (Liberar) AJUSTES GENERALES IDIOMA Menú principal [OK]  Ajustes  Idioma Main Menu (Menú principal) [OK]  Adjustment (Ajuste) DATOS TÉCNICOS Menú principal  Ajustes  Presión atmosférica En caso de restablecimiento se borrarán todos los datos. Realizar restablecimiento maestro: mantenga presionado el botón Reset en la parte posterior del instrumentos con un bolígrafo fino o un clip durante 3 segundos. 4 4.1 8 AJUSTE El HP3X dispone de una función de ajuste de la humedad y la temperatura que le permite el ajuste directamente con el instrumento de medición portátil. El instrumento puede tener un ajuste de 1 punto para la temperatura y un ajuste de 1 o 3 puntos para la humedad. HP32 HP-GTS Sondas HC2 y HC2A-S. Fijo Las sondas deben pedirse por separado. Rango de utilización -10…60°C | 0…100 %HR (sin cond.) Rango de utilización de -10…60 °C En función de la -10…60 °C las sondas sonda, p. ej. HC2A-S ±0,8 %HR / ±0,1 °C Precisión @ 23 °C ±2 %HR / ±0,3 °C ±2 %HR / ±0,3 °C Funciones Registro de puntos / Almacenamiento a intervalos MIN / MAX / AVG / MKT Intervalo de registro 1 s…24 h Memoria de medidas 8 x 8000 puntos de datos Cálculos psicrométricos Punto de rocío / Punto de escarcha (Dp/Fp) Temperatura de bulbo húmedo (Tw) Entalpía (H) Densidad de vapor de agua (Dv) Humedad específica (Q) Relación de peso-mezcla (R) Presión de vapor de agua (E) Presión de vapor de saturación (Ew) Densidad de saturación de vapor de agua (SVD) Frecuencia de actualización 1 s (típica) de pantalla Batería integrada 48 h – Registro cada 30 s, con la pantalla apagada 10 h – Con la pantalla encendida (típica) Interfaz de PC Conexión micro USB, compatible con HW4 Material de la carcasa ABS, TPR Tipo de protección IP IP65 Dimensiones 160 x 63 x 30 mm Peso 185 g Sondas compatibles HP31 Fijo 10 SE INCLUYE • HygroPalm HP-31/32/GTS • Softcase • Cable de servicio micro USB (AC0006) • Kit para hebilla de cinturón, cordón para el cuello y certificado Menú principal [OK]  Ajustes  Unidades Kit para hebilla de cinturón Español También puede activar una señal acústica para una alarma: Menú principal [OK]  Ajustes  Tono de señal 12.8000.2505ES Asegúrate de que la cabeza del enchufe no esté conectada con la polaridad invertida. Los límites de alarma sobrepasados se representan en rojo en la pantalla de inicio. Las opciones son las siguientes: • Distancia: m, ft • Temperatura: °C, °F • Presión: hPa, mmHg • Peso: kg, lbs www.rotronic.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Rotronic HP32 El manual del propietario

Tipo
El manual del propietario
Este manual también es adecuado para