36 electrolux
Instructions for the Installer
The manufacturer disclaims any
liability if the safety measures are not
observed.
Fig. 32
Installation and connectionInstallation and connection
Installation and connectionInstallation and connection
Installation and connection
must be done in compliancemust be done in compliance
must be done in compliancemust be done in compliance
must be done in compliance
with the regulations in force.with the regulations in force.
with the regulations in force.with the regulations in force.
with the regulations in force.
Any interventions must beAny interventions must be
Any interventions must beAny interventions must be
Any interventions must be
carried out when thecarried out when the
carried out when thecarried out when the
carried out when the
appliance is switched off.appliance is switched off.
appliance is switched off.appliance is switched off.
appliance is switched off.
Only accredited engineersOnly accredited engineers
Only accredited engineersOnly accredited engineers
Only accredited engineers
may work on the appliance.may work on the appliance.
may work on the appliance.may work on the appliance.
may work on the appliance.
The manufacturer disclaims any
liability if the safety measures are
not observed.
Connecting to the electrical supply
Before connecting to the electrical
supply, please make sure:
- The fuse and the domestic electrical
installation must be designed for the
max. load of the appliance (see
rating plate).
- The domestic electrical installation
must be equipped with a proper
earth connection in accordance with
the regulations in force.
- The socket or the multi-pole off
switch must be easy to access after
the appliance has been installed.
This appliance is delivered with an
electric supply cable.
A proper plug, according to the
electric load specified on the rating
plate, must be fitted to the cable. The
plug is to be inserted into a suitable wall
socket. If you require a direct connection
to the electric network (mains), it will be
necessary to fit between the appliance
and the mains an omnipole switch, with
a minimum gap between contacts of 3
mm, suitable for the required load and in
compliance with rules in force. The
green & yellow ground wire must not be
interrupted by the switch and it should
be 2-3 cm. longer than the other cables.
The mains cable and plug as
supplied are to be connected to a
shockproof socket (230 V~, 50 Hz). The
shockproof socket must be installed in
accordance with the regulations.
The following types of mains cable
are suitable, taking the necessary rated
cross section into account: H07 RN-F,
H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
The connection cable must in any
case be laid out so that at no point does
it reach 50°C (over room temperature).
After the connection has been
carried out, the heating elements must
be tested by being operated for about 3
minutes.
Terminal block
The oven is fitted with an easily
accessible terminal block which is
designed to operate with a single-phase
power supply of 230 V.
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal