Installation Instructions
Models: CQ52
The Quest Fan
CQ52
Read and Save These Safety Precautions
1. Turn off electricity at main switch before wiring or servicing fan in order to avoid
possible electrical shock.
2. All wiring must be in accordance with the National Electric Code (ANSI/NFPA 70-
1999) and local electrical codes. Electrical installation should be performed by a qualified
licensed electrician.
3. After making the wire connections, the wires should be spread apart with the grounded
conductor and the equipment-grounding conductor on the one side of the outlet box
and the ungrounded conductor on the other side of the outlet box.
4. The splices after being made should be turned upward and pushed carefully up into
the outlet box.
5. Conductor of a fan identified as grounded conductor to be connected to grounded
conductor of power supply, conductor of a fan identified as ungrounded conductor to
be connected to an ungrounded conductor of power supply, conductor of fan identified
for equipment grounding to be connected to an equipment-grounding conductor.
6. Fan should not be mounted in an area where it might get wet.
7. To r educe the risk of fire, electric shock or personal injury, mount to outlet box marked
"Acceptable for Fan Support" and use mounting screws provide with the outlet box.
8. For safety and best operating results, we recommend that you have a qualified electrician
assemble and install your fan.
9. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any
solid state speed control device.
10. To reduce the risk of personal injury, do not bend the blade brackets when installing
the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
Before Assembly
1. Make sure that the fan voltage (120) is compatible with your own electrical system.
2. Check to make sure that your carton contains all the parts mentioned in the parts list.
NOTE: When the motor is taken out of carton, please put it in a soft cloth to prevent any
damage on the ornamental surface.
CAUTION: Before installing, choose a location for mounting the fan where the blades have
at least 7 feet of clearance from all objects and floor. Mount an outlet box to the ceiling or
use an existing box.
CAUTION: Do not mount fan to sheet rock or drywall type materials. To insure proper
support, use the two #1 wood screws to secure mounting bracket to joist or beam. If the
location you choose does not have a suitable support beam, install a 2”X4” brace between
ceiling joists to support.
Tools You Need
1. Phillips
Screwdriver
(included)
3. Adjustable
Wrench
2. Flat
Screwdriver
4. Wire Strippers
What You Have
PartsQuantity
1. Mounting Bracket 1
2. Down Rod Assembly 2
4" & 6" Rods Supplied
(Use desired length)
3. Canopy 1
4. Decorative Cover Cap 1
5. Fan Motor 1
6. Blades (sold separately) 5
7. Phillips Screwdriver 1
Destornillador Phillips 1
8. TCS Wall Control 1
9. Housing Clip 1
10. Foam Insert (top) 1
12
4
Screw Package Quantity
S1. Wood Screws and Washers 2
S2. Screws (for Canopy) 3
S3. Bracket Screws & Washers 2
S4. Blade Screws 16
S5. Wire Connectors 3
S6. Safety Bolt & Nut 1
S7. "J" Hook 1
S8. Zip Tie 1
7
3
5
6
109
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
8
S2
S1
S4
S3
S7 S8
S5
S6
Step 1
Turn off circuit breakers and wall switch to the fan
supply line leads.
Warning: Failure to disconnect power supply prior to
installation may result in serious injury or death.To reduce
the risk of shock, this fan must be installed with an
isolating wall control/switch.
1
Step 3
Check to make sure blades are at
least 30” from any obstruction.
Check downrod length to
ensure blades are at least
7' above the floor.
3
84”
(2.1m)
Min.
30”
0.75m
Min.
Preparation
Important: When using an existing outlet box, be sure the box is securely attached
to the building structure and can support the full weight of the fan. Failure to do
so can result in serious injury or death.
Step 2
Determine mounting method to use.
A. Downrod Mount
B. Angle Mount
Craftmade Part #45AD (see dealer)
2
IMPORTANT: If using the angle mount
method, check to make sure the ceiling angle
is not steeper than 35°. Angles greater than
35° will require a 45° angle adapter.
Downrod Installation
(Vaulted Ceilings)
Downrod Installation
(Normal Ceilings)
Step 4
Prior to securing mounting bracket, screw "J" hook (S7) into ceiling outlet
box as a secondary support means. Secure mounting bracket (#1) to the
outlet box (A) by tightening bracket screws & washers (S3) as shown. If
not mounting to an outlet box, use wood screws (S1) and washers (S3) and
mount securely to ceiling beam. Be sure at this point to insert canopy screws
(S2) in bracket.
NOTE: Do not mount directly to sheet rock or ceiling tile.
NOTE: J Hook installation is a Canadian requirement only.
4
OUTLET BOX
Outlet Box (A)
Mounting Bracket (1)
Bracket Screws
& Washers (S3)
Support Beam
Wood Screws (S1)
Canopy Screws (S2)
Ceiling
Wood Screws (S1)
“J” Hook (S7)
6
Step 6
Setting Frequency Switches
The wall control unit is operated by a set of frequency switches and are
preset at the factory. There are two sets of frequency switches. The switches
on the wall control are located on the front panel under the insert plate.
The switches on the fan unit are located in the receiving module on top of
the fan unit (see diagram). The switches can be set in any position as long
as both the wall unit and receiving module switches are set the same. All
(RF) modules & Transmitters come from the factory with the dip switches
set in the (ON) position. Reattach top motor housing (#5) with the four
screws taken out previously.
Note: In the event there are multiple remote units in an area, dip switches can be set to
different settings so one remote doesn't inadvertently turn on more than one fan.
1
2
34
O
N
1234
ON
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
1234
ON
6
Helpul Hint
Remove fan motor (#5) from inside the box, turn the top foam insert
(#10) upside down, then lay the fan motor face down into the foam.
This will hold the motor housing steady during assembly.
5
Step 5
Take out the four screws in the top motor housing (#5). Save the screws.
Raise the top motor housing (#5) off the base (see figure 1). Slide blade
(#6) through slot on side of fan. Attach with blade screws (S4) as shown
in figure 2. Repeat this procedure until all five blades are secured. Tighten
firmly. Top motor housing will be reattached in following step.
Figure 1
Motor Housing (#5)
Top Motor Housing (#5)
CAUTION: Never hold or lift fan by blades
Figure 2
Blade Screws (S4)
Top View
8
Step 8
Position downrod so the hole in the downrod aligns with the hole in
the flange coupling on the motor. Insert safety bolt (S6) through coupling
and downrod and attach nut. Tighten firmly. Tighten set screw "A"
against downrod. Connect antenna wire and place decorative cover (#4)
and canopy (#3) over downrod assembly. Replace hanging ball, insert
hanging pin through downrod and tighten set screw "C" in hanging ball
into downrod.
WARNING:
Failure to completely tighten downrod as described in steps 7 & 8 above could
result in the fan loosening and possibly falling.
IMPORTANT: Black antenna wire must be connected for fan to function.
Safety Bolt & Nut
Set Screw (A)
Canopy (3)
Motor Housing (5)
Set Screw (C)
Downrod (2)
Decor Cover (4)
Antenna Wire
Ground
Wire
Ball
Screw
Hanging
Pin
Hanging
Ball
Threaded
Set Screw Hole
Step 7
Locate downrod assembly (#2). Loosen ball screw on black hanging ball
to free lock pin. Black hanging ball will slide down. Remove ground
screw and green ground wire. Remove hanging ball from downrod and
save all parts. Insert fan wires through downrod. Screw downrod into
top of fan motor housing, being careful that wires are pulled through.
7
Hanging Ball
Lock Pin
Downrod
Ball Screw
Green Ground
Wire
Downrod
Assembly
(#2)
Fan Motor Housing
9
Step 9
For added security, attach safety cable from fan unit to "J" hook (S7) in
outlet box. Secure by looping zip tie (S8) through safety cable and "J" hook.
Tighten zip tie securely. Lift fan onto the mounting bracket (#1). Turn
housing until hanging ball seats itself into ball socket (listen for click).
NOTE: Parts furnished will allow
you to install your fan at up to a 35°
angle. Angles greater than 35° will
require a 45° angle adapter (see
dealer).
NOTE: J Hook installation is a
Canadian requirement only.
Outlet Box (A)
Support Beam
Ceiling
Green Ground Wire
“J” Hook (S7)
OUTLET BOX
“J” Hook (S7)
Safety Cable
Zip Tie (S8)
Mounting Bracket (#1)
WARNING: To reduce the risk of fire, electric shock or personal injury, mount
so outlet box marked "acceptable for fan support" and use mounting screws
provided with the outlet box. Most outlet boxes commonly used for the support
of lighting fixtures are not acceptable for fan support and may need to be replaced.
Consult a qualified electrician if in doubt.
Step 10
1. Connect fan wires to ceiling wires: white fan wire to white outlet wire,
black to black and green to green. Wire connectors (S5) are provided for
your convenience. If an additional blue wire is present then also connect the
blue wire to the black wire. (Optional light kit may be wired to individual
wall switches, if desired.)
2. After connections
are made, turn
splices upward
and push carefully
into outlet box.
Separate blue and
black wires on one
side of the box, and
white and green wires
on the other side.
There are 3 colored
wires coming from the
top of the motor
(including ground wire).
10
White (Neutral)
Ground
White
Black
Wire
Connectors
(S5)
Ground
(Green)
Black (Power)
Downrod Ground
(Green)
Mounting Bracket
Ground (Green)
Outlet Box
Ground (Green)
Wire Connnections
Outlet Box Fan wires
Black Black
(Hot wire for fan)
Green Green (Ground wire)
White White (Neutral wire)
13
Step 13
Wiring Instructions
NOTE: Use instructions packed with celing fan to wire ceiling fan.
WARNING: To avoid overheating and possible damage to his device and
other equipment, do not install to control a receptacle, fluorescent lighting,
transformer, or motor-operated appliance other than the fans for which
this control is intended. Use this device only with copper or copper clad
wire. With aluminum wire use only devices marked CO/ALR.
1. Remove insulation to expose 3/4" bare copper wire at end of circuit
conductors. Keep wire ends straight.
2. Connect wires per wiring diagram as follows: black leads (one each)
to black (hot) line, green ground wire to copper outlet wire. Hold
bare ends together. Push wires firmly into wire connector. Screw
connector on clockwise until no bare copper shows. Secure connector
with electrical tape.
CAUTION: Never attach white neutral wire to TCS+ Control
3. Make sure battery is properly installed in switch. The switch should
already have this preinstalled, but double check before installing the
mounting plate (see diagram). Note: The battery replacement code is
23A 12Volt.
4. Mount device with long mounting screws (provided). Install wallplate
and tighten cover screws.
5. Restore power at circuit breaker or fuse. Installation is complete.
Neutral
(White Wire)
Hot Line
(Black Wire)
SINGLE POLE
Neutral
(White Wire)
Load
(Black Wire)
23A 12Volt
Battery
HI
MED
LOW
OFF
L-1
L-2
REV
OFF
ON
12V. BATT.
SUPER
23A 12V
1234
ON
Ground Wire
(Copper Wire)
Ground Wire
(Green Wire)
11
Step 11
Attach canopy (#3) to the
mounting bracket by placing
screws (S2) into slot in canopy.
Twist clockwise to lock
into place. Tighten screws firmly.
Bottom of Canopy
Screws (S2)
Canopy (3)
Ceiling
12
Step 12
Install halogen light bulb into fan. Seat bulb firmly into socket as shown.
Then install glass by raising glass to fan and turning glass clockwise
until firmly seated.
Halogen Bulb
Housing Clip (#9)
Motor Housing Access
To access motor housing, take out the four screws in the top motor housing
(#8). Save the screws. Raise the top motor housing and decor cover cap up
the downrod. Secure both pieces by attaching the housing clip (#9)
underneath the top motor housing by clipping it on and tightening the set
screw. This will give access to the blade assembly area.
14
Electrical Connections
Connect black fan wires to black outlet wire. Connect white fan wire to
white outlet wire and green grounding lead wire from the grounding
conductor to the supply circuit (see figure A). Use wire connectors provided
with your fan. No loose strands or loose connections should be present.
Turn splices upward and carefully push all wiring into outlet box. When
wall switches are employed, switches should be UL listed for use with
ceiling fan.
Fan and lights
controlled by remote
control unit.
Ground
Black
White
Black
White
Green
CAUTION: Always turn off power at breaker before attempting any wire
connections.
Operation Instructions
ON/OFF For emergency shut off.
HIGH Controls fan motor speed. To select desired speed,
MEDIUM press button once and release
LOW
REVERSE Controls direction of fan blades. To reverse fan blades, press once and
release.
FAN OFF Tu rns fan motor speed off. Press once to turn off. To start motor speed
again, hit one of the motor speed buttons.
L-1 Controls no function on this fan.
L-2 Controls the on/off and intensity for integrated light kit. Push and
release for on/off function. Hold down for full range light dimming.
NOTE: The "High", "Medium" or "Low" buttons may be used to start the fan
motor. The speed of the fan may be changed at any time.
Common Problems
Problem A: Fan Will not Start
Remedies: 1. Check fuse or circuit breaker and replace if necessary
2. Turn off electrical power and check all wire connectors.
3. Check on/off TCS and wall control selector switch. See operation
instructions.
Problem B: Fan is Excessively Noisy
Remedies: 1. Check that all screws in fan assembly are tight and properly seated.
2. Check to make sure mounting bracket is installed properly.
3. Check to make sure light kit and glass reinstalled properly and tight.
4. If wall control is used, insure the wall control is not a transformer or a
variable speed type.
Problem C: Fan Wobbles
Remedies: 1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are screwed firmly into motor.
3. Check the weight of blades. All our blades are weighed on electronic scales.
The weight is marked on the reverse side of the fan blade near the motor
end. All of the blades should be the same weight to prevent fan from
wobbling.
4. A balancing kit is enclosed if needed.
Weight: The weight of the complete fan, including assembly hardware is 36 lbs.
®
MEJOR DISEÑO
Instrucciones de instalación
Modelos: CQ52
Ventiladore de
Quest
CQ52
Lea y conserve estas precauciones de seguridad
1. Apague la electricidad con el interruptor principal antes de cablear o dar servicio al
ventilador para evitar posibles choques eléctricos.
2. Todo el cableado eléctrico debe acatar los códigos eléctricos nacionales (ANSI/NFPA
70-1999) y los códigos eléctricos locales. Un electricista capacitado debe realizar la
instalación eléctrica.
3. Después de realizar las conexiones de cableado, deben separarse los cables con el
conductor a tierra y el conductor de tierra del equipo en un lado de la caja de salida y
el conductor sin tierra al otro lado de la caja de salida.
4. Una vez efectuados los empalmes deben girarse hacia arriba y empujarse con cuidado
dentro de la caja de salida.
5. El conductor de un ventilador identificado como conductor a tierra debe conectarse
al conductor a tierra de un suministro de alimentación, el conductor de un ventilador
identificado como conductor sin tierra debe conectarse a un conductor sin tierra del
suministro de alimentación; el conductor de un ventilador identificado para conectar
a tierra el equipo debe conectarse a un conductor para tal efecto.
6. No debe montarse el ventilador en un área donde pueda mojarse
7. Para aminorar el riesgo de un incendio, choque eléctrico o lesión personal, móntelo a
una caja de salida adecuada para soportar el ventilador ("Acceptable for Fan Support")
y utilice los tornillos de montaje incluidos con la caja de salida.
8. Por motivos de seguridad y para obtener óptimos resultados, recomendamos que pida
a un electricista capacitado ensamblar e instalar el ventilador.
9. ADVERTENCIA: Para reducir el peligro de incendio o choque eléctrico, no use este
ventilador con ningún dispositivo de control de velocidad de estado sólido.
10. Para aminorar el riesgo de una lesión personal, no doble los soportes de las aspas al
instalar los soportes, equilibrar las aspas o limpiar el ventilador. No introduzca objetos
extraños entre las aspas giratorias del ventilador.
36
Herramientas necesarias
1. Destornillador
Phillips
(incluido)
3. Llava
ajustable
2. Destornillador
de hoja plana
4. Pelacables
Antes del montaje
1. Revise que el voltaje (120) del ventilador sea compatible con su propio sistema eléctrico.
2. Compruebe que la caja contenga todas las piezas mencionadas en la lista correspondiente.
NOTA: Cuando se extraiga el motor de la caja, póngalo sobre un paño suave para evitar
dañar la superficie ornamental.
PRECAUCIÓN: Antes de instalar, elija una ubicación para montar el ventilador donde las
aspas tengan por lo menos 7 pies (2.1 m) de altura desde el piso y todo objeto. Monte una
caja de salida en el cielo raso o use una caja existente.
PRECAUCIÓN: No monte el ventilador en materiales de tipo tablaroca o paneles de yeso.
Para asegurar un soporte adecuado use los dos tornillos para madera (1) para asegurar el
soporte de montaje a la viga. Si la ubicación que ha seleccionado no tiene una viga de soporte
que sirva, instale una abrazadera de 2" x 4" (5 x 10 cm) entre las vigas del cielo raso para
soportar el ventilador.
Componentes Incluidos
Piezas Cantidad
1. Soporte de montaje 1
2. Ensamblaje de vara hacia 2
abajo, se suministra vara
de 2 y 6 pulg. (5 y 15 cm)
(Use el largo deseado)
3. Cúpula 1
4. Tapa decorativa de la cubierta 1
5. Motor del ventilador 1
6. Aspas (se venden por separado) 5
7. Destornillador Phillips 1
8. Control de la pared TCS 1
9. Grapa de la caja 1
10. Inserto de espuma (parte superior) 1
12
4
Paquete de herraje Cantidad
S1. Tornillos para madera y arandela 2
S2. Tornillos (para la cúpula) 3
S3. Tornillos de soporte y arandela 2
S4. Tornillos de las aspas 16
S5. Conectores de cables 3
S6. Perno y tuerca de seguridad 1
S7. El Cancho "J" 1
S8. Amarra 1
7
3
5
6
109
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
8
S2
S1
S4
S3
S7 S8
S5
S6
Paso 1
Apague los disyuntores y el interruptor de la pared hacia
los conductores de suministro del ventilador.
Advertencia: Si no se desconecta el suministro de alimentación
antes de la instalación puede ocasionar lesiones graves o fatales.
Este ventilador debe instalarse con un interruptor/control
aislante de pared para reducir el riesgo de electrochoque.
1
Preparación
Importante: Al utilizar una caja de salida existente, revise que la caja esté conectada
firmemente a la estructura de la edificación y que pueda soportar el peso total del
ventilador. De lo contrario puede ocasionar lesiones graves o fatales.
Paso 3
Revise que las aspas queden por lo
menos a 30” (76 cm) de toda
obstrucción. Compruebe la
longitud de la vara hacia abajo
para que las aspas queden por
lo menos a 7 pies (2 metros) del piso.
3
84 pulg
(2.1m)
Mín.
30 pulg
0.75m
Mín.
Paso 2
Determine el método de montaje a usar.
A. Montaje con vara hacia abajo
B. Montaje angular
Pieza Craftmade 45AD
(consulte al distribuidor)
2
IMPORTANTE: Si utiliza el método de montaje
angular, revise que el ángulo del cielo raso no supere
los 35°. Los ángulos mayores de 35° necesitarán un
adaptador angular de 45°.
Instalación con vara hacia abajo
(cielos rasos abovedados)
Instalación con vara hacia abajo
(cielos rasos normales)
Paso 4
Antes de sujetar el soporte de montaje, atornille el gancho “J” (S7) en la caja de
salida del techo como medio de soporte secundario. Asegure el soporte de montaje
(1) a la caja de salida (A) apretando los tornillos del soporte y las arandelas (S3)
como se muestra. Si no se monta en una caja de salida, use tornillos para madera
(S1) y arandelas (S3), montando firmemente en una viga del cielo raso. En este
punto deben insertarse los tornillos de cúpula (S2) en el soporte.
NOTA: No monte directamente en paneles de yeso o láminas de techo.
NOTA:
La instalación del Gancho J es un requisito canadiense sólo.
4
OUTLET BOX
Caja de salida (A)
Soporte de montaje (1)
Tornillos de soporte
y arandelas (S3)
Viga de soporte
Tornillos para madera (S1)
Tornillos para
la cúpula (S2)
Cielo raso
Tornillos para madera (S1)
CAJA DE SALIDA
Gancho “J”(S7)
6
Paso 6
Ajuste de los interruptores de frecuencia
Un conjunto de interruptores de frecuencia preajustados de fábrica operan la
unidad de control para la pared. Hay dos conjuntos de interruptores de frecuencia.
Los interruptores del control de pared están situados en el panel delantero, debajo
de la placa de inserción. Los interruptores del ventilador están situados en el
módulo receptor sobre el ventilador (consulte el diagrama). Los interruptores
pueden colocarse en cualquier posición, siempre que sea la misma posición tanto
para el interruptor de la unidad para la pared como el interruptor del módulo
receptor. Todos los transmisores y módulos (RF) vienen de la fábrica con los
interruptores “DIP” colocados en la posición de ENCENDIDO (ON). Vuelva
a unir la parte superior de la caja del motor (#5) utilizando los cuatro tornillos
que previamente sacó y puso al lado.
Nota: En caso de haber varias unidades de control remoto en un lugar, los interruptores "DIP"
pueden ajustarse de manera distinta para que un control remoto no encienda accidentalmente
más de un ventilador.
12
34
O
N
1234
ON
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
1234
ON
5
Paso 5
Saque los cuatro tornillos que se encuentran en la parte superior de la caja
del motor (#5). Póngalos a un lado. Luego, levante la caja superior del motor
(#5) de la base (vea la figura 1). Deslice la aspa (#6) a través de la ranura
situada al lado del ventilador. Fije con los tornillos de las aspas (S4) como
lo muestra la figura 2. Repita este procedimieno hasta haber fijado todas las
cinco aspas. Atornille firmemente. En el siguiente paso, usted volverá a unir
la parte superior de la caja del motor.
Una recomendación útil
Saque el motor del ventilador (#5) del interior de la caja del empaque,
voltee el inserto de espuma (#10) al revés, luego coloque el motor del ventilador
cara abajo sobre la espuma. Esto le permitirá mantener estable la caja del
motor durante el ensamblaje.
Figura 1
Motor del ventilador (#5)
Parte superior de la caja del motor (#5)
Figura 2
Tornillos de las aspas (S4)
PRECAUCIÓN: Nunca levante o detenga el ventilador por las aspas.
Top View
8
Paso 8
Sitúe la vara hacia abajo de manera que el agujero en la misma quede alineado
con el agujero en el acoplamiento del motor. Inserte el perno de seguridad (S6)
en el acoplamiento y la vara hacia abajo e instale la tuerca. Apriete bien.
Apriete el tornillo de fijación “A” contra la vara hacia abajo. Conecte el cable
de la antena y coloque la cubierta decorativa (#4) y la cúpula (#3) sobre el
ensamblaje de la vara hacia abajo. Reinstale la bola colgante, inserte el pasador
colgante en la vara hacia abajo y apriete el tornillo de fijación “C” en la bola
colgante al interior de la vara hacia abajo.
ADVERTENCIA:
Si no se aprieta totalmente la vara hacia abajo como se describe en los pasos 7 y 8
anteriores podría soltarse y tal vez caerse el ventilador.
IMPORTANTE: El cable de antena negro debe estar conectado para que el
ventilador funcione.
Perno y tuerca
de seguridad
Tornillo de fijación (A)
Cúpula (3)
Caja del motor (5)
Tornillo de fijación (C)
Vara hacia abajo (2)
Cubierta decorativa (4)
Cable de antena
Cable
a tierra
Tornillo
de bola
Pasador
colgante
Bola
colgante
Agujero para
tornillo de
fijación
roscado
Paso 7
Ubique el ensamblaje de la vara hacia abajo (2). Suelte el tornillo de la
bola negra colgante para liberar el pasador de bloqueo. La bola negra colgante
se deslizará hacia abajo. Retire el tornillo a tierra y el cable a tierra de color
verde. Retire la bola colgante de la vara hacia abajo y guarde todas las piezas.
Inserte los cables del ventilador por la vara hacia abajo. Atornille la vara
hacia abajo en el extremo superior de la caja del motor del ventilador,
teniendo cuidado que hayan pasado los cables.
7
Bola colgante
Pasador de bloqueo
Vara hacia abajo
Tornillo de bola
Cable verde
a tierra
Ensamblaje
de la vara
hacia abajo
(2)
Caja del motor del ventilador
6
9
Paso 9
Para mayor seguridad, instale un lazo de alambre de acero desde el ventilador
al gancho “J” (S7) en la caja de salida. Sujételo pasando la amarra (S8) por
el cable de seguridad y el gancho “J”. Apriete bien la amarra. Levante el
ventilador hacia el soporte de montaje (1). Gire la caja hasta que la bola
colgante se asiente en el hueco de la bola (se debe escuchar un chasquido).
NOTA: Las piezas suministradas le permitirán instalar el ventilador en un ángulo de hasta
35°. Los ángulos mayores de 35° necesitarán un adaptador angular de 45°
(consulte con el proveedor).
NOTA: La instalación del Gancho J es un requisito canadiense sólo.
ADVERTENCIA: Móntelo en la caja de salida marcada “acceptable for fan support”
(aceptable como soporte del ventilador) con los tornillos suministrados con la caja para
reducir el riesgo de incendio o lesiones personales. La mayoría de las cajas de salida
de uso común para el soporte de portalámparas no son aceptables para el soporte del
ventilador y podría ser necesario reemplazarlas. Consulte con un electricista competente
en caso de dudas
CAJA DE SALIDA
Gancho “J” (S7)
Cable de seguridad
Amarra
(S8)
Caja de salida (A)
Viga de soporte
Cielo raso
Soporte de montaje (1)
Cable verde a tierra
Gancho “J” (S7)
Paso 10
1. Conecte los cables del ventilador a los del techo: el cable blanco del ventilador
con el cable blanco de salida, negro con negro y verde con verde. Se incluyen los
conectores de cables (S5) para su conveniencia. Si hay un cable azul adicional,
conéctelo también con el cable negro. (El paquete de iluminación opcional puede
cablearse a interruptores individuales de pared, si se prefiere.)
2. Después de efectuar las
conexiones, gire los empalmes
hacia arriba y empújelos
con cuidado dentro
de la caja de salida.
Separe los cables
azul y negro
en un lado de la
caja y los cables blanco y
verde en el otro lado.
Hay 3 cables de colores
que salen de la parte
superior del motor
(incluido el cable a tierra).
10
Blanco (Neutro)
Tierra
Blanco
Negro
Conectores
de cables
(S5)
Tierra
(Verde)
Negro (Alimentación)
Tierra de la vara
hacia abajo (Verde)
Tierra del soporte
de montaje (Verde)
Tierra de la caja
de salida (Verde)
Conexiones de cables
Caja de salida Cables del ventilador
Negro Negro (Cable energizado
para el ventilador)
Verde Verde (Cable a tierra)
Blanco Blanco (Cable neutro)
13
Paso 13
Instrucciones de cableado
NOTA: Siga las instrucciones incluidas con el ventilador de techo para cablearlo.
ADVERTENCIA: Para evitar el recalentamiento y posible daño a este dispositivo
y otro equipo, no lo instale para controlar un tomacorriente, luces fluorescentes,
transformador o electrodoméstico a motor, excepto por los ventiladores para los
cuales se diseñó este control. Use este dispositivo con alambre de cobre o revestido
en cobre únicamente. Con alambre de aluminio, use dispositivos marcados
CO/ALR únicamente.
1. Quite el aislamiento para exponer el alambre de cobre de _ pulg. al extremo
de los conductores del circuito. Mantenga rectos los extremos de los cables.
2. 2. Conecte los cables según el diagrama de cableado de la siguiente manera:
las terminales negras (cada una de ellas) a la línea negra (energizada),
el cable verde a tierra al cable de cobre de salida. Una los extremos desnudos.
Empuje firmemente los cables en el conector. Atornille el conector de tornillo
en sentido horario hasta que no quede cobre desnudo a la vista. Afiance
el conector con cinta aislante.
PRECAUCIÓN: Nunca conecte el cable neutro blanco al Control TCS+
3. Asegúrese de que la pila esté instalada correctamente en el interruptor.
Ésta ya debería estar instalada en el interruptor, pero confírmelo antes de
instalar la placa de montaje (ver diagrama). Nota: El código de reemplazo
de la pila es 23 A, 12 Voltios.
4. Monte el dispositivo con los tornillos largos de montaje (incluidos). Instale
la placa para la pared y apriete los tornillos de la cubierta.
5. Restaure el suministro eléctrico en el cortacircuitos o fusible. Esto completa
la instalación.
Neutro
(Cable blanco)
Carga
(Cable negro)
MONOPOLAR
Línea
energizada
(Cable negro)
Pila de 23 A
y 12 Voltios
Neutro
(Cable blanco)
HI
MED
LOW
OFF
L-1
L-2
REV
OFF
ON
12V. BATT.
SUPER
23A 12V
1234
ON
Cable Tierre
(Cable Verde)
Cable Tierre
(Cable Cobre)
12
Paso 12
Instale el bombillo eléctrico halógeno en el ventilador. Asiente el bombillo
firmemente en el encaje, según se ve en el diagrama. Instale luego la tapa de
vidrio, alzándolo hasta el ventilador y girándolo en el sentido de las
manecillas del reloj, hasta que este firmemente asentado.
Bombillo de Halógeno
11
Paso 11
Instale la cúpula (3) en el soporte
de montaje colocando los tornillos
(S2) en la ranura de la cúpula.
Gire en el sentido de las manecillas
del reloj para bloquearla en su sitio.
Apriete los tornillos firmemente.
Parte inferior de la cúpula
Tornillos (S2)
Cúpula (3)
Cielo raso
14
Conexiones eléctricas
Conecte los cables negros del ventilador al cable negro de salida. Conecte el
cable blanco del ventilador al cable blanco de salida y al cable conductor a
tierra verde desde el conductor a tierra al circuito de suministro (consulte la
figura A). Utilice los conectores de cable suministrados con el ventilador. No
debe haber hilos sueltos ni conexiones sueltas. Gire los empalmes hacia arriba
y empuje con cuidado todas las conexiones dentro de la caja de salida. Cuando
se empleen interruptores de pared, estos deben ser aprobados por UL para uso
con un ventilador de techo.
Tierra
Negro
Blanco
Negro
Blanco
Verde
Ventilador y luces
controlados por la
unidad de control
remoto.
PRECAUCIÓN: Siempre apague la corriente en el cortacircuitos antes de
intentar conectar los cables.
Housing Clip (#9)
Grapa de la caja (#9)
Cómo llegar a la caja del motor
Para llegar a la caja del motor, saque los cuatro tornillos de la parte superior
de la caja del motor (#8). Ponga estos tornillos a un lado. Levante la parte
superior de la caja del motor y la tapa decorativa de la cubierta de la vara hacia
abajo. Fije ambas piezas con la grapa de la caja (#9) uniéndola a la vara por
debajo de la parte superior de la caja del motor sujetándola y apretando el
tornillo de fijación. Esto le permitirá llegar al eansamblaje de las aspas.
ENCENDIDO/APAGADO Para un paro de emergencia.
ALTO Controla la velocidad del motor del ventilador Oprima el botón una
MEDIO vez y suéltelo para seleccionar la velocidad deseada
BAJO
REVERSA Controla de dirección de las aspas del ventilador. Oprima una vez y suéltelo
para invertir la dirección de las aspas del ventilador.
VENTILADOR Apaga el motor del ventilador. Oprima una vez para apagar.
APAGADO Para arrancar nuevamente el motor, oprima uno de los botones
de velocidad del motor.
L-1 No controla ninguna función en este ventilador.
L-2 Controla la función de encendido y apagado (on/off) así como la intensidad
para el juego integrado de luz. Para encender y apagar, empuje y suelte; para
reducir toda la gama de luz, mantenga empujado hacia abajo.
NOTA: Los botones “Alto”, “Medio” o “Bajo” pueden usarse para arrancar el motor
del ventilador. La velocidad del ventilador puede cambiarse en cualquier
momento.
Problemas Comunes
Problema A: El ventilador no arranca
Soluciones: 1. Revise el fusible o disyuntor y cámbielo si es necesario.
2. Apague la alimentación eléctrica y revise todos los conectores de cables.
3. Inspeccione el interruptor TCS de encendido / apagado y el interruptor
selector de control para la pared. Consulte las instrucciones de
funcionamiento.
Problema B: El ventilador es demasiado ruidoso
Soluciones: 1. Revise que estén apretados y debidamente asentados todos los tornillos
del ensamblaje del ventilador.
2. Compruebe que el soporte de montaje esté instalado correctamente.
3. Compruebe que la unidad de luz y el vidrio estén correctamente instalados
y apretados.
4. Si se usa el control de pared, revise que no sea del tipo transformador o
de velocidad variable.
Problema C: El ventilador se balancea
Soluciones: 1. Revise que todas las aspas estén atornilladas firmemente en sus soportes.
2. Revise que todos los soportes de las aspas estén atornilladas firmemente
en el motor.
3. Revise el peso de las aspas. Todas nuestras aspas se pesan en balanzas
electrónicas. El peso aparece en el reverso del aspa cerca del extremo del
motor. Todas las aspas deben tener el mismo peso para evitar que el
ventilador se balancee.
4. Se adjunta un paquete de balanceo, si es necesario.
Peso: El peso del ventilador completo, incluido el herraje de montaje es de
36 lbs. (16.3 kg).
Ventilateurs de
plafond Quest
Instructions d’installation
Modèle : CQ52
®
UNE CONCEPTION EXCEPTIONNELLE
CQ52
Veuillez lire et conserver ces consignes de sécurité
1. Pour éviter de vous électrocuter, débranchez l'alimentation électrique au niveau de
l'interrupteur principal avant de procéder au câblage ou à l'entretien du ventilateur.
2. Tout le câblage doit être effectué en accord avec le code électrique national américain
(ANSI/NFPA 70-1999) et les codes électriques locaux. L'installation électrique doit être
effectuée par un électricien professionnel qualifié.
3. Une fois que les connexions ont été effectuées, les fils doivent être séparés. Le conducteur
mis à la masse et le conducteur de mise à la masse de l'équipement doivent être mis d'un
côté de la boîte de sortie et le conducteur non mis à la masse de l'autre côté.
4. Une fois qu'elles ont été faites, les épissures doivent être tournées vers le haut et les fils
doivent être soigneusement rentrés dans la boîte de sortie.
5. Le conducteur mis à la masse du ventilateur doit être branché sur le conducteur mis à la
masse de l'alimentation électrique, et le conducteur non mis à la masse du ventilateur doit
être branché sur le conducteur non mis à la masse de l'alimentation électrique. Le
conducteur du ventilateur destiné à la mise à la masse de l'équipement doit être connecté
à un conducteur de mise à la masse de l'équipement.
6. Le ventilateur ne peut être installé dans un endroit où il pourrait être mouillé.
7. Pour éviter les incendies, les décharges électriques ou les blessures, branchez le ventilateur
sur une boîte de sortie marquée « Prise en charge de ventilateur » et utilisez les vis de
montage fournies avec la boîte de sortie.
8. Par mesure de sécurité et pour obtenir les meilleurs résultats possibles, nous vous conseillons
de faire assembler et installer votre ventilateur par un électricien professionnel.
9. ATTENTION : pour éviter les incendies ou les décharges électriques, n'utilisez jamais
ce ventilateur avec un dispositif de contrôle de la vitesse à l’état solide.
10. Pour éviter de vous blesser, ne pliez jamais les supports de pales lorsque vous les installez,
les équilibrez ou que vous nettoyez le ventilateur. N'insérez jamais d'objet entre les pales
en mouvement du ventilateur.
Avant l'assemblage
1. Vérifiez que la tension du ventilateur (120) est compatible avec votre système électrique.
2. Assurez-vous que le carton d'emballage contient toutes les pièces mentionnées dans la
liste des pièces.
REMARQUE : une fois le moteur déballé, placez-le sur un tissu doux pour éviter que sa
surface décorée ne soit endommagée.
ATTENTION : avant de procéder à l'installation du ventilateur, choisissez un endroit où
ses pales seront à une distance d'au moins 2 m (7 pi) de tout objet environnant et du sol.
Installez une boîte de sortie au plafond ou bien utilisez une boîte existante.
ATTENTION : n'installez pas le ventilateur sur des cloisons sèches ou du plâtre. Pour que
l'appareil soit correctement fixé, accrochez les supports de montage à une poutrelle ou à une
poutre au moyen des deux vis à bois n° 1. Si l'emplacement choisi n'a pas de poutre de
soutien acceptable, installez une armature de 2 po X 4 po entre les poutrelles du plafond
pour y accrocher le ventilateur
Outils nécessaires à l'installation
1. Tournevis
Phillips
3. Clé réglable
2. Tournevis plat
4. Pince à dénuder
Composants inclus
Pièces Quantité
1. Support de montage 1
2. Assemblage de la tige de suspension
Tige de 15 cm (6 po) fournie
(Utilisez la longueur désirée) 1
3. Coupelle 1
4. Couvre-bride 1
5. Boîtier du ventilateur et du moteur 1
6. Pales (vendues séparément) 5
7. Tournevis Phillips 1
8. TCS Interrupteur mural 1
9. Clip de maintien du boîtier 1
10. Bande de mousse (supérieure) 1
12
4
Paquet de vis Quantité
S1. Vis à bois 2
S2. Vis (pour coupelle) 3
S3. Vis et rondelles des supports 2
S4. Vis des pales 16
S5. Connecteurs de fils 3
S6. Boulon et écrou de sécurité 1
S7. Crochet en « J » 1
S8. Bride 1
7
3
5
6
109
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
8
S2
S1
S4
S3
S7 S8
S5
S6
Étape 3
Assurez-vous que les pales du
ventilateur sont à 75 cm (30 po)
minimum de toute obstruction.
Mesurez la tige de suspension
pour vous assurer que les pales
sont à au moins 2 mètres
(7 pi) du sol.
3
2,1 m
(84 po)
min.
0,75 m
(30 po)
min.
Préparation
Important: lorsque vous utilisez une boîte de sortie existante, assurez-vous que
cette dernière est correctement attachée à la structure du bâtiment et qu’elle peut
soutenir le poids total du ventilateur. Le non-respect de cette consigne peut entraîner
de graves blessures, voire la mort.
Étape 1
Désactivez les disjoncteurs et l'interrupteur mural
régissant les conducteurs d'alimentation du ventilateur.
Avertissement: le non débranchement de l'alimentation
électrique avant l'installation du ventilateur peut entraîner
de graves blessures, voire la mort. Pour éviter les décharges
électriques, ce ventilateur doit être installé avec un interrupteur
mural isolant.
1
Étape 2
Choisissez la méthode de montage que
vous désirez utiliser.
A. Montage à l’aide d’une tige de
suspension
B. Montage sur une surface inclinée
Pièce Craftmade n°45AD
(consultez votre revendeur)
2
IMPORTANT: si vous utilisez la méthode de
montage inclinée, vérifiez que l'angle du plafond
est inférieur à 35°. Si votre plafond est incliné
à un angle supérieur à 35°, vous devrez utiliser
un adaptateur d’angle à 45°
Montage à l’aide d’une tige de suspension
(Plafond en pente)
Montage à l’aide d’une tige de suspension
(Plafonds normaux)
Étape 4
Avant de fixer le support de montage, vissez le crochet en «J» (S7) sur la
boîte de sortie du plafond, pour qu’il serve de dispositif de soutien
supplémentaire. Fixez le support de montage (n° 1) à la boîte de sortie (A)
en resserrant les vis et les rondelles (S3) de support de la manière illustrée.
Si vous n'installez pas le ventilateur sur une boîte de sortie, utilisez les vis
à bois (S1) et les rondelles (S3) pour installer solidement l'appareil à une
poutre du plafond. N'oubliez pas d'insérer les vis de la coupelle (S2) dans
le support.
REMARQUE : n'installez pas le ventilateur directement sur du plâtre ou sur des carreaux
de plafond.
REMARQUE : L'installation du crochet en J est une exigence canadienne seulement.
4
OUTLET BOX
Boîte de sortie (A)
Supports de montage (1)
Vis et rondelles
des supports (S3)
Poutre de soutien
Vis à bois (S1)
Vis de coupelle (S2)
Plafond
Vis à bois (S1)
Crochet en « J » (S7)
Conseil
Retirez le moteur du ventilateur (nº 5) du boîtier, retournez la bande de
mousse supérieure à l'envers (nº 10), puis posez le moteur du ventilateur,
à l'envers, sur la mousse. Cela permettra de maintenir le boîtier du moteur
en place pendant le montage.
5
Étape 5
Retirez les quatre (4) vis sur le haut du boîtier du moteur (nº 5). Conservez
ces vis. Soulevez le haut du boîtier du moteur (nº 5) de la base (voir la figure
1). Faites glisser les pales (nº 6) dans les fentes situées sur le côté du ventilateur.
Fixez les pales à l'aide des vis prévues à cet effet (S4), comme l'indique la
figure 2. Répétez cette procédure jusqu'à ce que les cinq pales soient bien
mises en place. Serrez fermement. Le haut du boîtier du moteur sera remis
en place à l'étape suivante.
Figure 1
Boîtier du moteur (nº 5)
Haut du boîtier du moteur (nº 5)
Figure 2
Vis de pale (S4)
Vue supérieure
ATTENTION : Ne jamais tenir ou soulever le
ventilateur par les pales.
6
Étape 6
Réglage des interrupteurs à fréquence
L'unité de commande murale fonctionne grâce à un ensemble d'interrupteurs
à fréquence qui sont préréglés en usine. Il existe deux ensembles d'interrupteurs
à fréquence. Les interrupteurs sur la commande murale se situent sur le
panneau frontal, sous la plaque. Les interrupteurs sur le ventilateur se situent
sur le module de réception placé sur le haut du ventilateur (voir schéma).
Les interrupteurs peuvent être réglés sur n'importe quelle position, à
condition toutefois que les interrupteurs de l'unité murale et du module
de réception soient positionnés sur les mêmes réglages. Tous les modules
(RF) et émetteurs sont livrés de l'usine avec les commutateurs DIP réglés
en position ON (Marche). Remettez le haut du boîtier du moteur en place
(nº 5) à l'aide des quatre vis retirées précédemment.
Remarque : Dans le cas où il y aurait plusieurs unités radiocommandées dans une zone,
des commutateurs DIP peuvent être réglés sur différents réglages de façon à ce qu'une
unité n'interfère pas avec les autres ventilateurs et ne les mette pas en marche par inadvertance.
12
34
O
N
1234
ON
OFF
12V BAT.
ON
HIGH
MED.
LOW
FAN OFF
L-1
L-2
REVERSE
1234
ON
8
Étape 8
Placez la tige de suspension de manière à ce que son trou soit aligné avec
celui de l’attelage du moteur. Insérez le boulon de sécurité (S6) dans l’attelage
et la tige de suspension et fixez l'écrou. Serrez fermement. Serrez la vis de
fixation « A » contre la tige de suspension. Enfoncez le couvre-bride (n° 4)
sur l'assemblage de la tige de suspension jusqu'à ce qu'il couvre la bride.
Placez la coupelle (3) sur la tige de suspension (n° 2). Replacez la boule
pendante. Pour cela, insérez la douille pendante dans la tige de suspension
et serrez la vis de fixation « C » dans la boule pendante jusqu'à ce qu'elle
pénètre dans la tige de suspension.
AVERTISSEMENT: si vous ne serrez pas complètement la tige de suspension
en suivant les instructions des étapes 7 et 8, le ventilateur peut se desserrer et
éventuellement tomber.
IMPORTANT : le fil d’antenne noir doit être connecté pour que le ventilateur
fonctionne.
Boulon et écrou de sécurité (S6)
Vis de fixation (A)
Coupelle (n° 3)
Boîtier du moteur
(n° 5)
Vis de fixation (C)
Tige de suspension
(n° 2)
Couvre-bride (n° 4)
Fil d'antenne
Fil de terre
Vis de
boule
Douille
pendante
Boule
pendante
Trou de vis
de fixation fileté
Étape 7
Repérez l'assemblage de tige de suspension (n° 2). Desserrez la vis de
boule située sur la boule pendante noire pour dégager la goupille de
verrouillage. La boule pendante noire glissera vers le bas. Retirez la vis
de mise à la terre et le fil de terre vert. Retirez la boule pendante de la
tige de suspension et conservez toutes les pièces. Insérez les fils du
ventilateur à travers la tige de suspension. Vissez la tige de suspension
dans la partie supérieure du boîtier de moteur du ventilateur, en faisant
attention à ce que les fils soient complètement passés.
7
Goupille de
verrouillage
Boîtier du moteur
du ventilateur
Boule pendante
Tige de
suspension
Vis de boule
Fil de terre vert
Assemblage
de la tige de
suspension(2)
9
Étape 9
Pour plus de sécurité, attachez le câble de sécurité du ventilateur au crochet
en « J » (S7) accroché dans la boîte de sortie. Fixez l'installation en faisant
passer la bride (S8) dans le câble de sécurité et dans le crochet en «J».
Resserrez fortement la bride. Installez le ventilateur sur le support de
montage (n° 1). Faites pivoter le boîtier jusqu'à ce que la boule pendante
s’installe dans son réceptacle (vous devriez entendre un déclic).
NOTE: les pièces fournies vous
permettront d'installer votre
ventilateur à un angle de 35°.
Pour toute installation à un angle
supérieur à 35°, vous aurez besoin
d'un adaptateur d'angle à 45°
(consultez votre revendeur).
NOTE: L'installation du crochet
en « J » est une exigence
canadienne seulement.
Boîte de sortie (A)
Poutre de soutien
Plafond
Fil de terre vert
Crochet en «J» (S7)
Crochet en « J » (S7)
Câble de sécurité
Bride (S8)
Support de montage (n° 1)
BOÎTE DE SORTIE
AVERTISSEMENT: Pour éviter les incendies, les décharges électriques ou les
blessures, branchez le ventilateur sur une boîte de sortie marquée « acceptable for
fan support » (prise en charge de ventilateur) et utilisez les vis de montage fournies
avec la boîte de sortie. La plupart des boîtes de sortie utilisées avec les dispositifs
d'éclairage ne prennent pas en charge les ventilateurs et doivent être éventuellement
remplacées. En cas de doute, consultez un électricien qualifié.
Étape 10
1. Connectez les fils du ventilateur à ceux du plafond : le fil de ventilateur
blanc au fil de sortie blanc, le fil noir au fil noir et le fil vert au fil vert. Les
connecteurs (S5) sont fournis au cas où vous en auriez besoin. S'il existe un
fil bleu supplémentaire, connectez-le au fil noir.
(Un kit d’éclairage en option
peut être connecté à des
interrupteurs muraux).
2. Une fois que les
connexions ont
été effectuées,
tournez les épissures
vers le haut et faites
rentrer soigneusement
le câblage dans la boîte
de sortie. Placez les fils
bleus et noirs d'un côté
de la boîte et les fils blancs
et verts de l'autre côté.
Des fils de quatre couleurs
différentes sortent du
dessus du moteur
(y compris le fil
de terre).
10
Blanc (neutre)
Fil de terre
Blanc
Noir
Connecteurs
(S5)
Fil de terre
(vert)
Noir (alimentation)
Fil de terre de la
tige de suspension
(vert)
Fil de terre de
la boîte de sortie
Fil de terre du
support
de montage (vert)
Boîte de sortie Fils du ventilateur
Noir Noir (Fil chargé du ventilateur)
Ver t
Vert (Fil de terre)
Blanc Blanc (Fil neutre)
Fils de connexion
Instructions de câblage
REMARQUE : câblez le ventilateur conformément aux instructions qui
l’accompagnent.
ATTENTION : pour éviter de faire surchauffer et d’endommager la
commande et d’autres appareils, ne pas installer la commande pour contrôler
une prise de courant, un éclairage fluorescent, un transformateur ni un
appareil à moteur autre que les ventilateurs pour lesquels elle est conçue. Ne
l’utilisez qu’ave du fil de cuivre ou enrobé de cuivre. Seuls les dispositifs
marqués CO/ALR peuvent être utilisés avec du fil en aluminium.
1. Dénudez 19 mm (3/4 po) de fil de cuivre à l’extrémité des connecteurs
de circuits en enlevant l’isolant. Maintenez les extrémités dénudées bien
droites.
2. Effectuez les raccordements suivants conformément au schéma de câblage
: conducteurs noirs (deux) au fil secteur (sous tension) noir, fil vert de terre
au fil de cuivre de la boîte de sortie. Maintenez les extrémité dénudées l’une
contre l’autre. Enfoncez fermement les fils dans un connecteur et tournez
celui-ci dans le sens horaire jusqu’à ce que le cuivre à nu n’apparaisse plus.
Immobilisez le connecteur avec du chatterton. ATTENTION : ne branchez
jamais le fil neutre blanc à une commande à interrupteur mural.
3. Assurez-vous qu’une pile est installée correctement dans l’interrupteur.
Celui-ci doit déjà en être pourvu mais vérifiez que c’est le cas avant d’installer
la plaque de montage (voir le schéma). Remarque : le code de remplacement
de la pile est 23 A 12 V.
4. Montez le dispositif au moyen des vis de montage longues (fournies).
Installez la plaque murale et serrez les vis du couvercle.
5. Rétablissez l’alimentation au tableau électrique.
13
Neutre (fil blanc)Fil secteur sous
tension (noir)
UNIPOLAIRE
Neutre (fil blanc)Charge (fil noir)
Pile 12 V 23 A
HI
MED
LOW
OFF
L-1
L-2
REV
OFF
ON
12V. BATT.
SUPER
23A 12V
1234
ON
Fil de terre
(en cuivre)
Fil de terre (vert)
11
Étape 11
Fixez la coupelle (n° 3) au
support de montage en insérant
les vis (S2) dans ses fentes. Faites-
la tourner dans le sens des
aiguilles d'une montre pour
l'installer. Serrez fortement les
vis.
Partie inférieure
de la coupelle
Vis (S2)
Coupelle (n° 3)
Plafond
12
Étape 12
Installez l'ampoule halogène sur le ventilateur. Insérez fermement l'ampoule
dans la douille, comme indiqué sur le schéma. Installez ensuite le verre en
l'appliquant sur le ventilateur et en le tournant dans le sens des aiguilles
d'une montre jusqu'à ce qu'il soit bien encastré.
Ampoule d'halogène
Instructions d’utilisation
ON/OFF Pour arrêt d’urgence
HIGH Commande la vitesse du moteur du ventilateur. Pour choisir la
MEDIUM vitesse désirée, appuyez une fois sur le bouton et relâchez-le.
LOW
REVERSE Commande le sens de rotation des pales du ventilateur. Pour
inverser le sens de rotation des pales, appuyez une fois et relâchez.
FAN OFF Arrête le moteur du ventilateur. Appuyez une fois pour arrêter.
Pour remettre le moteur en marche, appuyez sur l'un des boutons
de vitesse du moteur.
L-1 Ne contrôle aucune fonction sur ce ventilateur.
L-2 Commande l’allumage/extinction et l’intensité du kit d’éclairage
intégré. Appuyez et relâchez pour commander l’allumage/extinction.
Maintenez enfoncé pour faire varier l’intensité sur toute sa plage.
REMARQUE : Il est possible d’utiliser les boutons «High», «Medium» ou «Low»
pour mettre le moteur du ventilateur en marche et de changer la
vitesse du ventilateur à tout moment.
Problèmes fréquents
Problème A : Le ventilateur ne démarre pas
Solution : 1. Vérifiez les fusibles ou le disjoncteur et remplacez-les si besoin est.
2. Coupez l'alimentation électrique et vérifiez tous les connecteurs.
3. Vérifiez les interrupteurs on/off ainsi que l'interrupteur de commande mural.
Consultez le mode d'emploi.
Problème B : Le ventilateur fait trop de bruit
Solution : 1. Vérifiez que toutes les vis du ventilateur sont serrées et correctement installées
2. Assurez-vous que le support de montage est correctement installé.
3. Assurez-vous que le kit d’éclairage et le verre ont été correctement réinstallés
et fixés.
4. Si vous utilisez une commande murale, assurez-vous qu'il ne s'agit pas d'un
transformateur ou d'une commande à vitesse variable.
Problème C : Le ventilateur oscille
Solution : 1. Vérifiez que toutes les pales sont correctement vissées sur les
supports de pales.
2. Vérifiez que tous les supports de pales sont vissés fermement sur le moteur.
3. Vérifiez le poids des pales. Toutes nos pales sont pesées sur des balances
électroniques. Le poids est marqué sur le dos de la pale, à côté de l'extrémité
du moteur. Toutes les pales doivent avoir le même poids pour que le ventilateur
n’oscille pas.
4. Un kit d'équilibrage des pales est fourni avec l'appareil.
Poids: un ventilateur complet, c'est-à-dire avec le matériel d'assemblage, pèse
36 lbs. (16.3 kg).
14
Connexions électriques
ATTENTION : coupez toujours le courant au tableau électrique avant de
procéder à tout raccordement de fils.
Ventilateur
et éclairage
contrôlés par
télécommande
Raccordez les fils noirs du ventilateur
à celui de la boîte de sortie, puis le fil
blanc du ventilateur à celui de la boîte
de sortie et le fil vert du conducteur de
mise à la terre au circuit d’alimentation
(voir la figure A). Utilisez les
connecteurs fournis avec le ventilateur.
Il ne doit y avoir aucun brin débranché
ni connexion desserrée. Faites pivoter
les épissures vers le haut et faites
soigneusement rentrer tous les fils dans
la boîte de sortie. Les interrupteurs
muraux utilisés doivent être homologués
UL pour pouvoir fonctionner avec un
ventilateur de plafond.
Fil de terre
Noir
Blanc
Blanc
Vert
Blanc
Accès au boîtier du moteur
Pour accéder au boîtier du moteur, retirez les quatre vis situées sur le haut
du boîtier du moteur (nº 8). Conservez ces vis. Soulevez le haut du boîtier
du moteur et la coupelle décorative le long de la tige. Maintenez ces deux
pièces soulevées à l'aide du clip (nº 9) que vous placez en dessous du boîtier
en le faisant glisser sur la tige et en serrant la vis. Cela vous permettra
d'accéder à la zone de montage des pales.
Clip de maintien du boîtier (nº 9)

Transcripción de documentos

The Quest Fan ® BETTER BY DESIGN P.O. Box 1037 650 S. Royal Lane, Suite 100 Coppell, TX 75019 (800) 486-4892 8:00 to 5:00 CST (Central Standard Time) Toll Free Fax: (877) 304-1728 email: [email protected] www.craftmade.com ® MEJOR DISEÑO P. O. Box 1037 650 S. Royal Lane, Suite 100 Coppell, TX 75019 EE.UU. CQ52 (800) 486- 4892 8:00 a 5:00 CST (Hora local central) Número de fax sin cargo: (877) 304-1728 Correo electrónico: [email protected] www. craftmade.com ® Installation Instructions Models: CQ52 UNE CONCEPTION EXCEPTIONNELLE P. O. Box 1037 650 S. Royal Lane, Suite 100 Coppell, TX 75019 EE.UU. de 8 heures à 17 heures (Heure standard du centre) Numéro de télécopieur gratuit : (877) 304-1728 Email: [email protected] www. craftmade.com ® BETTER BY DESIGN Read and Save These Safety Precautions Turn off electricity at main switch before wiring or servicing fan in order to avoid possible electrical shock. All wiring must be in accordance with the National Electric Code (ANSI/NFPA 701999) and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 3. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on the one side of the outlet box and the ungrounded conductor on the other side of the outlet box. 4. The splices after being made should be turned upward and pushed carefully up into the outlet box. 5. Conductor of a fan identified as grounded conductor to be connected to grounded conductor of power supply, conductor of a fan identified as ungrounded conductor to be connected to an ungrounded conductor of power supply, conductor of fan identified for equipment grounding to be connected to an equipment-grounding conductor. 6. Fan should not be mounted in an area where it might get wet. 7. To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked "Acceptable for Fan Support" and use mounting screws provide with the outlet box. 8. For safety and best operating results, we recommend that you have a qualified electrician assemble and install your fan. 9. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state speed control device. 10. To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades. What You Have 1. 1 2. Parts 2 Quantity 1. 2. Mounting Bracket Down Rod Assembly 4" & 6" Rods Supplied (Use desired length) 3. Canopy 4. Decorative Cover Cap 5. Fan Motor 6. Blades (sold separately) 7. Phillips Screwdriver Destornillador Phillips 8. TCS Wall Control 9. Housing Clip 10. Foam Insert (top) L-1 HIGH MED. L-2 LOW REVERSE 6 1 2 3 4 1 1 1 5 1 1 1 1 1 8 5 7 9 10 FAN OFF 12V BAT. OFF ON Before Assembly 1. Make sure that the fan voltage (120) is compatible with your own electrical system. 2. Check to make sure that your carton contains all the parts mentioned in the parts list. NOTE: When the motor is taken out of carton, please put it in a soft cloth to prevent any damage on the ornamental surface. CAUTION: Before installing, choose a location for mounting the fan where the blades have at least 7 feet of clearance from all objects and floor. Mount an outlet box to the ceiling or use an existing box. CAUTION: Do not mount fan to sheet rock or drywall type materials. To insure proper support, use the two #1 wood screws to secure mounting bracket to joist or beam. If the location you choose does not have a suitable support beam, install a 2”X4” brace between ceiling joists to support. Tools You Need Screw Package S1. S2. S3. S4. S5. S6. S7. S8. Wood Screws and Washers Screws (for Canopy) Bracket Screws & Washers Blade Screws Wire Connectors Safety Bolt & Nut "J" Hook Zip Tie Quantity 2 3 2 16 3 1 1 1 S1 S2 S3 S4 S5 S6 1. Phillips Screwdriver (included) 2. Flat Screwdriver 3. Adjustable Wrench 4. Wire Strippers S7 S8 Preparation Important: When using an existing outlet box, be sure the box is securely attached to the building structure and can support the full weight of the fan. Failure to do so can result in serious injury or death. 1 Step 1 Turn off circuit breakers and wall switch to the fan supply line leads. 4 Step 4 Prior to securing mounting bracket, screw "J" hook (S7) into ceiling outlet box as a secondary support means. Secure mounting bracket (#1) to the outlet box (A) by tightening bracket screws & washers (S3) as shown. If not mounting to an outlet box, use wood screws (S1) and washers (S3) and mount securely to ceiling beam. Be sure at this point to insert canopy screws (S2) in bracket. NOTE: Do not mount directly to sheet rock or ceiling tile. NOTE: J Hook installation is a Canadian requirement only. Warning: Failure to disconnect power supply prior to installation may result in serious injury or death.To reduce the risk of shock, this fan must be installed with an isolating wall control/switch. 2 Support Beam “J” Hook (S7) Step 2 Outlet Box (A) Ceiling Determine mounting method to use. A. Downrod Mount B. Angle Mount OUTLET BOX Mounting Bracket (1) Downrod Installation (Normal Ceilings) Craftmade Part #45AD (see dealer) Bracket Screws & Washers (S3) Wood Screws (S1) Wood Screws (S1) IMPORTANT: If using the angle mount method, check to make sure the ceiling angle is not steeper than 35°. Angles greater than 35° will require a 45° angle adapter. 3 Canopy Screws (S2) Downrod Installation (Vaulted Ceilings) Step 3 Check to make sure blades are at least 30” from any obstruction. Check downrod length to ensure blades are at least 7' above the floor. 30” 0.75m Min. 84” (2.1m) Min. Helpul Hint Remove fan motor (#5) from inside the box, turn the top foam insert (#10) upside down, then lay the fan motor face down into the foam. This will hold the motor housing steady during assembly. 5 Step 5 Take out the four screws in the top motor housing (#5). Save the screws. Raise the top motor housing (#5) off the base (see figure 1). Slide blade (#6) through slot on side of fan. Attach with blade screws (S4) as shown in figure 2. Repeat this procedure until all five blades are secured. Tighten firmly. Top motor housing will be reattached in following step. 6 Step 6 Setting Frequency Switches The wall control unit is operated by a set of frequency switches and are preset at the factory. There are two sets of frequency switches. The switches on the wall control are located on the front panel under the insert plate. The switches on the fan unit are located in the receiving module on top of the fan unit (see diagram). The switches can be set in any position as long as both the wall unit and receiving module switches are set the same. All (RF) modules & Transmitters come from the factory with the dip switches set in the (ON) position. Reattach top motor housing (#5) with the four screws taken out previously. Note: In the event there are multiple remote units in an area, dip switches can be set to different settings so one remote doesn't inadvertently turn on more than one fan. Figure 1 Top Motor Housing (#5) HIGH 6 1 2 3 4 ON Motor Housing (#5) L-1 MED. L-2 LOW REVERSE FAN OFF 1 2 3 4 ON 12V BAT. OFF Blade Screws (S4) Figure 2 Top View CAUTION: Never hold or lift fan by blades 1 ON 2 3 4 ON 7 8 Step 7 Locate downrod assembly (#2). Loosen ball screw on black hanging ball to free lock pin. Black hanging ball will slide down. Remove ground screw and green ground wire. Remove hanging ball from downrod and save all parts. Insert fan wires through downrod. Screw downrod into top of fan motor housing, being careful that wires are pulled through. Lock Pin Step 8 Position downrod so the hole in the downrod aligns with the hole in the flange coupling on the motor. Insert safety bolt (S6) through coupling and downrod and attach nut. Tighten firmly. Tighten set screw "A" against downrod. Connect antenna wire and place decorative cover (#4) and canopy (#3) over downrod assembly. Replace hanging ball, insert hanging pin through downrod and tighten set screw "C" in hanging ball into downrod. Green Ground Wire Threaded Set Screw Hole Ball Screw Downrod Assembly (#2) Hanging Pin Ground Wire Set Screw (C) Downrod (2) Hanging Ball Downrod Hanging Ball Ball Screw Canopy (3) Decor Cover (4) Antenna Wire Safety Bolt & Nut Fan Motor Housing Set Screw (A) Motor Housing (5) WARNING: Failure to completely tighten downrod as described in steps 7 & 8 above could result in the fan loosening and possibly falling. IMPORTANT: Black antenna wire must be connected for fan to function. 9 Step 9 For added security, attach safety cable from fan unit to "J" hook (S7) in outlet box. Secure by looping zip tie (S8) through safety cable and "J" hook. Tighten zip tie securely. Lift fan onto the mounting bracket (#1). Turn housing until hanging ball seats itself into ball socket (listen for click). Support Beam “J” Hook (S7) Outlet Box (A) OUTLET BOX Ceiling Mounting Bracket (#1) Green Ground Wire “J” Hook (S7) 10 Step 10 1. Connect fan wires to ceiling wires: white fan wire to white outlet wire, black to black and green to green. Wire connectors (S5) are provided for your convenience. If an additional blue wire is present then also connect the blue wire to the black wire. (Optional light kit may be wired to individual wall switches, if desired.) 2. After connections Ground are made, turn Wire splices upward White (Neutral) Connectors (S5) and push carefully into outlet box. Black (Power) Separate blue and black wires on one side of the box, and Ground white and green wires (Green) White on the other side. Black There are 3 colored wires coming from the top of the motor (including ground wire). Outlet Box Ground (Green) Zip Tie (S8) NOTE: Parts furnished will allow you to install your fan at up to a 35° angle. Angles greater than 35° will require a 45° angle adapter (see dealer). Safety Cable Downrod Ground (Green) NOTE: J Hook installation is a Canadian requirement only. WARNING: To reduce the risk of fire, electric shock or personal injury, mount so outlet box marked "acceptable for fan support" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. Mounting Bracket Ground (Green) Wire Connnections Outlet Box Fan wires Black Black (Hot wire for fan) Green Green (Ground wire) White White (Neutral wire) 11 13 Step 11 Attach canopy (#3) to the mounting bracket by placing screws (S2) into slot in canopy. Twist clockwise to lock into place. Tighten screws firmly. Ceiling Canopy (3) Screws (S2) Step 13 Wiring Instructions NOTE: Use instructions packed with celing fan to wire ceiling fan. WARNING: To avoid overheating and possible damage to his device and other equipment, do not install to control a receptacle, fluorescent lighting, transformer, or motor-operated appliance other than the fans for which this control is intended. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR. 1. Remove insulation to expose 3/4" bare copper wire at end of circuit conductors. Keep wire ends straight. Bottom of Canopy 12 Step 12 Install halogen light bulb into fan. Seat bulb firmly into socket as shown. Then install glass by raising glass to fan and turning glass clockwise until firmly seated. 2. Connect wires per wiring diagram as follows: black leads (one each) to black (hot) line, green ground wire to copper outlet wire. Hold bare ends together. Push wires firmly into wire connector. Screw connector on clockwise until no bare copper shows. Secure connector with electrical tape. CAUTION: Never attach white neutral wire to TCS+ Control 3. Make sure battery is properly installed in switch. The switch should already have this preinstalled, but double check before installing the mounting plate (see diagram). Note: The battery replacement code is 23A 12Volt. 4. Mount device with long mounting screws (provided). Install wallplate and tighten cover screws. 5. Restore power at circuit breaker or fuse. Installation is complete. Load (Black Wire) 23A 12Volt Battery HI Neutral (White Wire) L-1 MED L-2 LOW REV OFF 1 2 3 4 ON 12V. BATT. SUPER 23A 12V OFF ON SINGLE POLE Halogen Bulb Ground Wire (Green Wire) Hot Line (Black Wire) Neutral (White Wire) Ground Wire (Copper Wire) 14 Motor Housing Access Electrical Connections Connect black fan wires to black outlet wire. Connect white fan wire to white outlet wire and green grounding lead wire from the grounding conductor to the supply circuit (see figure A). Use wire connectors provided with your fan. No loose strands or loose connections should be present. Turn splices upward and carefully push all wiring into outlet box. When wall switches are employed, switches should be UL listed for use with ceiling fan. To access motor housing, take out the four screws in the top motor housing (#8). Save the screws. Raise the top motor housing and decor cover cap up the downrod. Secure both pieces by attaching the housing clip (#9) underneath the top motor housing by clipping it on and tightening the set screw. This will give access to the blade assembly area. Ground White Black Housing Clip (#9) Black Green White Fan and lights controlled by remote control unit. CAUTION: Always turn off power at breaker before attempting any wire connections. Operation Instructions ON/OFF For emergency shut off. HIGH MEDIUM LOW Controls fan motor speed. To select desired speed, press button once and release REVERSE Controls direction of fan blades. To reverse fan blades, press once and release. FAN OFF Turns fan motor speed off. Press once to turn off. To start motor speed again, hit one of the motor speed buttons. L-1 Controls no function on this fan. L-2 Controls the on/off and intensity for integrated light kit. Push and release for on/off function. Hold down for full range light dimming. NOTE: The "High", "Medium" or "Low" buttons may be used to start the fan motor. The speed of the fan may be changed at any time. Ventiladore de Quest CQ52 Common Problems Problem A: Fan Will not Start Remedies: 1. Check fuse or circuit breaker and replace if necessary 2. Turn off electrical power and check all wire connectors. 3. Check on/off TCS and wall control selector switch. See operation instructions. Problem B: Fan is Excessively Noisy Remedies: 1. 2. 3. 4. Check that all screws in fan assembly are tight and properly seated. Check to make sure mounting bracket is installed properly. Check to make sure light kit and glass reinstalled properly and tight. If wall control is used, insure the wall control is not a transformer or a variable speed type. Instrucciones de instalación Modelos: CQ52 Problem C: Fan Wobbles Remedies: Weight: 1. Check that all blades are screwed firmly into blade holders. 2. Check that all blade holders are screwed firmly into motor. 3. Check the weight of blades. All our blades are weighed on electronic scales. The weight is marked on the reverse side of the fan blade near the motor end. All of the blades should be the same weight to prevent fan from wobbling. 4. A balancing kit is enclosed if needed. The weight of the complete fan, including assembly hardware is 36 lbs. ® MEJOR DISEÑO Lea y conserve estas precauciones de seguridad 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Apague la electricidad con el interruptor principal antes de cablear o dar servicio al ventilador para evitar posibles choques eléctricos. Todo el cableado eléctrico debe acatar los códigos eléctricos nacionales (ANSI/NFPA 70-1999) y los códigos eléctricos locales. Un electricista capacitado debe realizar la instalación eléctrica. Después de realizar las conexiones de cableado, deben separarse los cables con el conductor a tierra y el conductor de tierra del equipo en un lado de la caja de salida y el conductor sin tierra al otro lado de la caja de salida. Una vez efectuados los empalmes deben girarse hacia arriba y empujarse con cuidado dentro de la caja de salida. El conductor de un ventilador identificado como conductor a tierra debe conectarse al conductor a tierra de un suministro de alimentación, el conductor de un ventilador identificado como conductor sin tierra debe conectarse a un conductor sin tierra del suministro de alimentación; el conductor de un ventilador identificado para conectar a tierra el equipo debe conectarse a un conductor para tal efecto. No debe montarse el ventilador en un área donde pueda mojarse Para aminorar el riesgo de un incendio, choque eléctrico o lesión personal, móntelo a una caja de salida adecuada para soportar el ventilador ("Acceptable for Fan Support") y utilice los tornillos de montaje incluidos con la caja de salida. Por motivos de seguridad y para obtener óptimos resultados, recomendamos que pida a un electricista capacitado ensamblar e instalar el ventilador. ADVERTENCIA: Para reducir el peligro de incendio o choque eléctrico, no use este ventilador con ningún dispositivo de control de velocidad de estado sólido. Para aminorar el riesgo de una lesión personal, no doble los soportes de las aspas al instalar los soportes, equilibrar las aspas o limpiar el ventilador. No introduzca objetos extraños entre las aspas giratorias del ventilador. Componentes Incluidos 1 Piezas 2 Cantidad 1. 2. Soporte de montaje Ensamblaje de vara hacia abajo, se suministra vara de 2 y 6 pulg. (5 y 15 cm) (Use el largo deseado) 3. Cúpula 4. Tapa decorativa de la cubierta 5. Motor del ventilador 6. Aspas (se venden por separado) 7. Destornillador Phillips 8. Control de la pared TCS 9. Grapa de la caja 10. Inserto de espuma (parte superior) L-1 HIGH MED. L-2 LOW REVERSE 6 1 2 3 4 1 1 1 5 1 1 1 1 8 5 7 9 10 FAN OFF 12V BAT. OFF ON Antes del montaje 1. Revise que el voltaje (120) del ventilador sea compatible con su propio sistema eléctrico. 2. Compruebe que la caja contenga todas las piezas mencionadas en la lista correspondiente. NOTA: Cuando se extraiga el motor de la caja, póngalo sobre un paño suave para evitar dañar la superficie ornamental. PRECAUCIÓN: Antes de instalar, elija una ubicación para montar el ventilador donde las aspas tengan por lo menos 7 pies (2.1 m) de altura desde el piso y todo objeto. Monte una caja de salida en el cielo raso o use una caja existente. PRECAUCIÓN: No monte el ventilador en materiales de tipo tablaroca o paneles de yeso. Para asegurar un soporte adecuado use los dos tornillos para madera (1) para asegurar el soporte de montaje a la viga. Si la ubicación que ha seleccionado no tiene una viga de soporte que sirva, instale una abrazadera de 2" x 4" (5 x 10 cm) entre las vigas del cielo raso para soportar el ventilador. Paquete de herraje S1. S2. S3. S4. S5. S6. S7. S8. Cantidad Tornillos para madera y arandela Tornillos (para la cúpula) Tornillos de soporte y arandela Tornillos de las aspas Conectores de cables Perno y tuerca de seguridad El Cancho "J" Amarra 2 3 2 16 3 1 1 1 S1 S2 S3 S4 Herramientas necesarias 36 1. Destornillador Phillips (incluido) 2. Destornillador de hoja plana S5 3. Llava ajustable 4. Pelacables S6 S7 S8 Preparación Importante: Al utilizar una caja de salida existente, revise que la caja esté conectada firmemente a la estructura de la edificación y que pueda soportar el peso total del ventilador. De lo contrario puede ocasionar lesiones graves o fatales. 1 Paso 1 Apague los disyuntores y el interruptor de la pared hacia los conductores de suministro del ventilador. 4 Paso 4 Antes de sujetar el soporte de montaje, atornille el gancho “J” (S7) en la caja de salida del techo como medio de soporte secundario. Asegure el soporte de montaje (1) a la caja de salida (A) apretando los tornillos del soporte y las arandelas (S3) como se muestra. Si no se monta en una caja de salida, use tornillos para madera (S1) y arandelas (S3), montando firmemente en una viga del cielo raso. En este punto deben insertarse los tornillos de cúpula (S2) en el soporte. NOTA: No monte directamente en paneles de yeso o láminas de techo. NOTA: La instalación del Gancho J es un requisito canadiense sólo. Advertencia: Si no se desconecta el suministro de alimentación antes de la instalación puede ocasionar lesiones graves o fatales. Este ventilador debe instalarse con un interruptor/control aislante de pared para reducir el riesgo de electrochoque. Viga de soporte Gancho “J”(S7) 2 Caja de salida (A) Paso 2 Cielo raso Determine el método de montaje a usar. A. Montaje con vara hacia abajo B. Montaje angular Pieza Craftmade 45AD (consulte al distribuidor) Soporte de montaje (1) Instalación con vara hacia abajo (cielos rasos normales) Tornillos para madera (S1) Tornillos para la cúpula (S2) Instalación con vara hacia abajo (cielos rasos abovedados) Paso 3 Revise que las aspas queden por lo menos a 30” (76 cm) de toda obstrucción. Compruebe la longitud de la vara hacia abajo para que las aspas queden por lo menos a 7 pies (2 metros) del piso. Tornillos de soporte y arandelas (S3) Tornillos para madera (S1) IMPORTANTE: Si utiliza el método de montaje angular, revise que el ángulo del cielo raso no supere los 35°. Los ángulos mayores de 35° necesitarán un adaptador angular de 45°. 3 OUTLET BOX CAJA DE SALIDA 30 pulg 0.75m Mín. 84 pulg (2.1m) Mín. Una recomendación útil Saque el motor del ventilador (#5) del interior de la caja del empaque, voltee el inserto de espuma (#10) al revés, luego coloque el motor del ventilador cara abajo sobre la espuma. Esto le permitirá mantener estable la caja del motor durante el ensamblaje. 5 Paso 5 Saque los cuatro tornillos que se encuentran en la parte superior de la caja del motor (#5). Póngalos a un lado. Luego, levante la caja superior del motor (#5) de la base (vea la figura 1). Deslice la aspa (#6) a través de la ranura situada al lado del ventilador. Fije con los tornillos de las aspas (S4) como lo muestra la figura 2. Repita este procedimieno hasta haber fijado todas las cinco aspas. Atornille firmemente. En el siguiente paso, usted volverá a unir la parte superior de la caja del motor. 6 Paso 6 Ajuste de los interruptores de frecuencia Un conjunto de interruptores de frecuencia preajustados de fábrica operan la unidad de control para la pared. Hay dos conjuntos de interruptores de frecuencia. Los interruptores del control de pared están situados en el panel delantero, debajo de la placa de inserción. Los interruptores del ventilador están situados en el módulo receptor sobre el ventilador (consulte el diagrama). Los interruptores pueden colocarse en cualquier posición, siempre que sea la misma posición tanto para el interruptor de la unidad para la pared como el interruptor del módulo receptor. Todos los transmisores y módulos (RF) vienen de la fábrica con los interruptores “DIP” colocados en la posición de ENCENDIDO (ON). Vuelva a unir la parte superior de la caja del motor (#5) utilizando los cuatro tornillos que previamente sacó y puso al lado. Nota: En caso de haber varias unidades de control remoto en un lugar, los interruptores "DIP" pueden ajustarse de manera distinta para que un control remoto no encienda accidentalmente más de un ventilador. Figura 1 Parte superior de la caja del motor (#5) HIGH 1 2 3 4 ON Motor del ventilador (#5) L-1 MED. L-2 LOW REVERSE FAN OFF 1 2 3 4 ON 12V BAT. Tornillos de las aspas (S4) Figura 2 Top View PRECAUCIÓN: Nunca levante o detenga el ventilador por las aspas. OFF 1 ON 2 3 4 ON 7 8 Paso 7 Ubique el ensamblaje de la vara hacia abajo (2). Suelte el tornillo de la bola negra colgante para liberar el pasador de bloqueo. La bola negra colgante se deslizará hacia abajo. Retire el tornillo a tierra y el cable a tierra de color verde. Retire la bola colgante de la vara hacia abajo y guarde todas las piezas. Inserte los cables del ventilador por la vara hacia abajo. Atornille la vara hacia abajo en el extremo superior de la caja del motor del ventilador, teniendo cuidado que hayan pasado los cables. Pasador de bloqueo Sitúe la vara hacia abajo de manera que el agujero en la misma quede alineado con el agujero en el acoplamiento del motor. Inserte el perno de seguridad (S6) en el acoplamiento y la vara hacia abajo e instale la tuerca. Apriete bien. Apriete el tornillo de fijación “A” contra la vara hacia abajo. Conecte el cable de la antena y coloque la cubierta decorativa (#4) y la cúpula (#3) sobre el ensamblaje de la vara hacia abajo. Reinstale la bola colgante, inserte el pasador colgante en la vara hacia abajo y apriete el tornillo de fijación “C” en la bola colgante al interior de la vara hacia abajo. Agujero para tornillo de fijación roscado Cable verde a tierra Tornillo de bola Ensamblaje de la vara hacia abajo (2) Paso 8 Bola colgante Pasador colgante Bola colgante Cable a tierra Tornillo de fijación (C) Vara hacia abajo (2) Tornillo de bola Cúpula (3) Cubierta decorativa (4) Vara hacia abajo Cable de antena Perno y tuerca de seguridad Tornillo de fijación (A) Caja del motor del ventilador Caja del motor (5) ADVERTENCIA: Si no se aprieta totalmente la vara hacia abajo como se describe en los pasos 7 y 8 anteriores podría soltarse y tal vez caerse el ventilador. IMPORTANTE: El cable de antena negro debe estar conectado para que el ventilador funcione. 96 10 Paso 9 Para mayor seguridad, instale un lazo de alambre de acero desde el ventilador al gancho “J” (S7) en la caja de salida. Sujételo pasando la amarra (S8) por el cable de seguridad y el gancho “J”. Apriete bien la amarra. Levante el ventilador hacia el soporte de montaje (1). Gire la caja hasta que la bola colgante se asiente en el hueco de la bola (se debe escuchar un chasquido). Viga de soporte Gancho “J” (S7) CAJA DE SALIDA Caja de salida (A) Cielo raso Soporte de montaje (1) Cable verde a tierra Paso 10 1. Conecte los cables del ventilador a los del techo: el cable blanco del ventilador con el cable blanco de salida, negro con negro y verde con verde. Se incluyen los conectores de cables (S5) para su conveniencia. Si hay un cable azul adicional, conéctelo también con el cable negro. (El paquete de iluminación opcional puede cablearse a interruptores individuales de pared, si se prefiere.) 2. Después de efectuar las conexiones, gire los empalmes Tierra hacia arriba y empújelos con cuidado dentro Conectores de cables de la caja de salida. Blanco (Neutro) (S5) Separe los cables Negro (Alimentación) azul y negro en un lado de la caja y los cables blanco y Tierra verde en el otro lado. (Verde) Blanco Hay 3 cables de colores que salen de la parte Negro superior del motor (incluido el cable a tierra). Gancho “J” (S7) Tierra de la caja de salida (Verde) Amarra (S8) Cable de seguridad Tierra de la vara hacia abajo (Verde) NOTA: Las piezas suministradas le permitirán instalar el ventilador en un ángulo de hasta 35°. Los ángulos mayores de 35° necesitarán un adaptador angular de 45° (consulte con el proveedor). NOTA: La instalación del Gancho J es un requisito canadiense sólo. Tierra del soporte de montaje (Verde) ADVERTENCIA: Móntelo en la caja de salida marcada “acceptable for fan support” (aceptable como soporte del ventilador) con los tornillos suministrados con la caja para reducir el riesgo de incendio o lesiones personales. La mayoría de las cajas de salida de uso común para el soporte de portalámparas no son aceptables para el soporte del ventilador y podría ser necesario reemplazarlas. Consulte con un electricista competente en caso de dudas Conexiones de cables Caja de salida Cables del ventilador Negro Negro (Cable energizado para el ventilador) Verde Blanco Verde (Cable a tierra) Blanco (Cable neutro) 11 13 Paso 11 Instale la cúpula (3) en el soporte de montaje colocando los tornillos (S2) en la ranura de la cúpula. Gire en el sentido de las manecillas del reloj para bloquearla en su sitio. Apriete los tornillos firmemente. Cielo raso Cúpula (3) Tornillos (S2) Parte inferior de la cúpula 12 Paso 12 Instale el bombillo eléctrico halógeno en el ventilador. Asiente el bombillo firmemente en el encaje, según se ve en el diagrama. Instale luego la tapa de vidrio, alzándolo hasta el ventilador y girándolo en el sentido de las manecillas del reloj, hasta que este firmemente asentado. Paso 13 Instrucciones de cableado NOTA: Siga las instrucciones incluidas con el ventilador de techo para cablearlo. ADVERTENCIA: Para evitar el recalentamiento y posible daño a este dispositivo y otro equipo, no lo instale para controlar un tomacorriente, luces fluorescentes, transformador o electrodoméstico a motor, excepto por los ventiladores para los cuales se diseñó este control. Use este dispositivo con alambre de cobre o revestido en cobre únicamente. Con alambre de aluminio, use dispositivos marcados CO/ALR únicamente. 1. Quite el aislamiento para exponer el alambre de cobre de _ pulg. al extremo de los conductores del circuito. Mantenga rectos los extremos de los cables. 2. 2. Conecte los cables según el diagrama de cableado de la siguiente manera: las terminales negras (cada una de ellas) a la línea negra (energizada), el cable verde a tierra al cable de cobre de salida. Una los extremos desnudos. Empuje firmemente los cables en el conector. Atornille el conector de tornillo en sentido horario hasta que no quede cobre desnudo a la vista. Afiance el conector con cinta aislante. PRECAUCIÓN: Nunca conecte el cable neutro blanco al Control TCS+ 3. Asegúrese de que la pila esté instalada correctamente en el interruptor. Ésta ya debería estar instalada en el interruptor, pero confírmelo antes de instalar la placa de montaje (ver diagrama). Nota: El código de reemplazo de la pila es 23 A, 12 Voltios. 4. Monte el dispositivo con los tornillos largos de montaje (incluidos). Instale la placa para la pared y apriete los tornillos de la cubierta. 5. Restaure el suministro eléctrico en el cortacircuitos o fusible. Esto completa la instalación. Pila de 23 A y 12 Voltios HI Carga (Cable negro) Neutro (Cable blanco) Línea energizada (Cable negro) Neutro (Cable blanco) L-1 MED L-2 LOW REV OFF 1 2 3 4 ON 12V. BATT. SUPER 23A 12V OFF Bombillo de Halógeno Cable Tierre (Cable Verde) ON Cable Tierre (Cable Cobre) MONOPOLAR 14 Cómo llegar a la caja del motor Conexiones eléctricas Conecte los cables negros del ventilador al cable negro de salida. Conecte el cable blanco del ventilador al cable blanco de salida y al cable conductor a tierra verde desde el conductor a tierra al circuito de suministro (consulte la figura A). Utilice los conectores de cable suministrados con el ventilador. No debe haber hilos sueltos ni conexiones sueltas. Gire los empalmes hacia arriba y empuje con cuidado todas las conexiones dentro de la caja de salida. Cuando se empleen interruptores de pared, estos deben ser aprobados por UL para uso con un ventilador de techo. Para llegar a la caja del motor, saque los cuatro tornillos de la parte superior de la caja del motor (#8). Ponga estos tornillos a un lado. Levante la parte superior de la caja del motor y la tapa decorativa de la cubierta de la vara hacia abajo. Fije ambas piezas con la grapa de la caja (#9) uniéndola a la vara por debajo de la parte superior de la caja del motor sujetándola y apretando el tornillo de fijación. Esto le permitirá llegar al eansamblaje de las aspas. Tierra Blanco Negro Housing Clip (#9) Grapa de la caja (#9) Negro Verde Blanco Ventilador y luces controlados por la unidad de control remoto. PRECAUCIÓN: Siempre apague la corriente en el cortacircuitos antes de intentar conectar los cables. ENCENDIDO/APAGADO Para un paro de emergencia. ALTO MEDIO BAJO Controla la velocidad del motor del ventilador Oprima el botón una vez y suéltelo para seleccionar la velocidad deseada REVERSA Controla de dirección de las aspas del ventilador. Oprima una vez y suéltelo para invertir la dirección de las aspas del ventilador. VENTILADOR APAGADO Apaga el motor del ventilador. Oprima una vez para apagar. Para arrancar nuevamente el motor, oprima uno de los botones de velocidad del motor. L-1 No controla ninguna función en este ventilador. L-2 Controla la función de encendido y apagado (on/off ) así como la intensidad para el juego integrado de luz. Para encender y apagar, empuje y suelte; para reducir toda la gama de luz, mantenga empujado hacia abajo. NOTA: Los botones “Alto”, “Medio” o “Bajo” pueden usarse para arrancar el motor del ventilador. La velocidad del ventilador puede cambiarse en cualquier momento. Ventilateurs de plafond Quest CQ52 Problemas Comunes Problema A: El ventilador no arranca Soluciones: 1. Revise el fusible o disyuntor y cámbielo si es necesario. 2. Apague la alimentación eléctrica y revise todos los conectores de cables. 3. Inspeccione el interruptor TCS de encendido / apagado y el interruptor selector de control para la pared. Consulte las instrucciones de funcionamiento. Problema B: El ventilador es demasiado ruidoso Soluciones: 1. Revise que estén apretados y debidamente asentados todos los tornillos del ensamblaje del ventilador. 2. Compruebe que el soporte de montaje esté instalado correctamente. 3. Compruebe que la unidad de luz y el vidrio estén correctamente instalados y apretados. 4. Si se usa el control de pared, revise que no sea del tipo transformador o de velocidad variable. Instructions d’installation Modèle : CQ52 Problema C: El ventilador se balancea Soluciones: 1. Revise que todas las aspas estén atornilladas firmemente en sus soportes. 2. Revise que todos los soportes de las aspas estén atornilladas firmemente en el motor. 3. Revise el peso de las aspas. Todas nuestras aspas se pesan en balanzas electrónicas. El peso aparece en el reverso del aspa cerca del extremo del motor. Todas las aspas deben tener el mismo peso para evitar que el ventilador se balancee. 4. Se adjunta un paquete de balanceo, si es necesario. Peso: El peso del ventilador completo, incluido el herraje de montaje es de 36 lbs. (16.3 kg). ® UNE CONCEPTION EXCEPTIONNELLE Veuillez lire et conserver ces consignes de sécurité 1. Pour éviter de vous électrocuter, débranchez l'alimentation électrique au niveau de l'interrupteur principal avant de procéder au câblage ou à l'entretien du ventilateur. 2. Tout le câblage doit être effectué en accord avec le code électrique national américain (ANSI/NFPA 70-1999) et les codes électriques locaux. L'installation électrique doit être effectuée par un électricien professionnel qualifié. 3. Une fois que les connexions ont été effectuées, les fils doivent être séparés. Le conducteur mis à la masse et le conducteur de mise à la masse de l'équipement doivent être mis d'un côté de la boîte de sortie et le conducteur non mis à la masse de l'autre côté. 4. Une fois qu'elles ont été faites, les épissures doivent être tournées vers le haut et les fils doivent être soigneusement rentrés dans la boîte de sortie. 5. Le conducteur mis à la masse du ventilateur doit être branché sur le conducteur mis à la masse de l'alimentation électrique, et le conducteur non mis à la masse du ventilateur doit être branché sur le conducteur non mis à la masse de l'alimentation électrique. Le conducteur du ventilateur destiné à la mise à la masse de l'équipement doit être connecté à un conducteur de mise à la masse de l'équipement. 6. Le ventilateur ne peut être installé dans un endroit où il pourrait être mouillé. 7. Pour éviter les incendies, les décharges électriques ou les blessures, branchez le ventilateur sur une boîte de sortie marquée « Prise en charge de ventilateur » et utilisez les vis de montage fournies avec la boîte de sortie. 8. Par mesure de sécurité et pour obtenir les meilleurs résultats possibles, nous vous conseillons de faire assembler et installer votre ventilateur par un électricien professionnel. 9. ATTENTION : pour éviter les incendies ou les décharges électriques, n'utilisez jamais ce ventilateur avec un dispositif de contrôle de la vitesse à l’état solide. 10. Pour éviter de vous blesser, ne pliez jamais les supports de pales lorsque vous les installez, les équilibrez ou que vous nettoyez le ventilateur. N'insérez jamais d'objet entre les pales en mouvement du ventilateur. Composants inclus 1 Pièces 2 Quantité 1. Support de montage 2. Assemblage de la tige de suspension Tige de 15 cm (6 po) fournie (Utilisez la longueur désirée) 3. Coupelle 4. Couvre-bride 5. Boîtier du ventilateur et du moteur 6. Pales (vendues séparément) 7. Tournevis Phillips 8. TCS Interrupteur mural 9. Clip de maintien du boîtier 10. Bande de mousse (supérieure) HIGH L-1 MED. L-2 LOW REVERSE 6 1 3 4 1 1 1 1 5 1 1 1 1 8 5 7 9 10 FAN OFF 12V BAT. OFF ON Avant l'assemblage 1. Vérifiez que la tension du ventilateur (120) est compatible avec votre système électrique. 2. Assurez-vous que le carton d'emballage contient toutes les pièces mentionnées dans la liste des pièces. REMARQUE : une fois le moteur déballé, placez-le sur un tissu doux pour éviter que sa surface décorée ne soit endommagée. ATTENTION : avant de procéder à l'installation du ventilateur, choisissez un endroit où ses pales seront à une distance d'au moins 2 m (7 pi) de tout objet environnant et du sol. Installez une boîte de sortie au plafond ou bien utilisez une boîte existante. ATTENTION : n'installez pas le ventilateur sur des cloisons sèches ou du plâtre. Pour que l'appareil soit correctement fixé, accrochez les supports de montage à une poutrelle ou à une poutre au moyen des deux vis à bois n° 1. Si l'emplacement choisi n'a pas de poutre de soutien acceptable, installez une armature de 2 po X 4 po entre les poutrelles du plafond pour y accrocher le ventilateur Outils nécessaires à l'installation Paquet de vis S1. S2. S3. S4. S5. S6. S7. S8. Quantité Vis à bois Vis (pour coupelle) Vis et rondelles des supports Vis des pales Connecteurs de fils Boulon et écrou de sécurité Crochet en « J » Bride 2 3 2 16 3 1 1 1 S1 S2 S3 S4 S5 S6 1. Tournevis Phillips 2. Tournevis plat 3. Clé réglable 4. Pince à dénuder S7 S8 Préparation Important: lorsque vous utilisez une boîte de sortie existante, assurez-vous que cette dernière est correctement attachée à la structure du bâtiment et qu’elle peut soutenir le poids total du ventilateur. Le non-respect de cette consigne peut entraîner de graves blessures, voire la mort. 1 Étape 1 Désactivez les disjoncteurs et l'interrupteur mural régissant les conducteurs d'alimentation du ventilateur. Avant de fixer le support de montage, vissez le crochet en «J» (S7) sur la boîte de sortie du plafond, pour qu’il serve de dispositif de soutien supplémentaire. Fixez le support de montage (n° 1) à la boîte de sortie (A) en resserrant les vis et les rondelles (S3) de support de la manière illustrée. Si vous n'installez pas le ventilateur sur une boîte de sortie, utilisez les vis à bois (S1) et les rondelles (S3) pour installer solidement l'appareil à une poutre du plafond. N'oubliez pas d'insérer les vis de la coupelle (S2) dans le support. Étape 2 Poutre de soutien Choisissez la méthode de montage que vous désirez utiliser. A. Montage à l’aide d’une tige de suspension B. Montage sur une surface inclinée Crochet en « J » (S7) Boîte de sortie (A) Montage à l’aide d’une tige de suspension (Plafonds normaux) Pièce Craftmade n°45AD (consultez votre revendeur) Plafond OUTLET BOX Supports de montage (1) Vis et rondelles des supports (S3) IMPORTANT: si vous utilisez la méthode de montage inclinée, vérifiez que l'angle du plafond est inférieur à 35°. Si votre plafond est incliné à un angle supérieur à 35°, vous devrez utiliser un adaptateur d’angle à 45° 3 Étape 4 REMARQUE : n'installez pas le ventilateur directement sur du plâtre ou sur des carreaux de plafond. REMARQUE : L'installation du crochet en J est une exigence canadienne seulement. Avertissement: le non débranchement de l'alimentation électrique avant l'installation du ventilateur peut entraîner de graves blessures, voire la mort. Pour éviter les décharges électriques, ce ventilateur doit être installé avec un interrupteur mural isolant. 2 4 Montage à l’aide d’une tige de suspension (Plafond en pente) Étape 3 Assurez-vous que les pales du ventilateur sont à 75 cm (30 po) minimum de toute obstruction. Mesurez la tige de suspension pour vous assurer que les pales sont à au moins 2 mètres (7 pi) du sol. 0,75 m (30 po) min. 2,1 m (84 po) min. Vis à bois (S1) Vis à bois (S1) Vis de coupelle (S2) Conseil Retirez le moteur du ventilateur (nº 5) du boîtier, retournez la bande de mousse supérieure à l'envers (nº 10), puis posez le moteur du ventilateur, à l'envers, sur la mousse. Cela permettra de maintenir le boîtier du moteur en place pendant le montage. 5 Étape 5 Retirez les quatre (4) vis sur le haut du boîtier du moteur (nº 5). Conservez ces vis. Soulevez le haut du boîtier du moteur (nº 5) de la base (voir la figure 1). Faites glisser les pales (nº 6) dans les fentes situées sur le côté du ventilateur. Fixez les pales à l'aide des vis prévues à cet effet (S4), comme l'indique la figure 2. Répétez cette procédure jusqu'à ce que les cinq pales soient bien mises en place. Serrez fermement. Le haut du boîtier du moteur sera remis en place à l'étape suivante. 6 Étape 6 Réglage des interrupteurs à fréquence L'unité de commande murale fonctionne grâce à un ensemble d'interrupteurs à fréquence qui sont préréglés en usine. Il existe deux ensembles d'interrupteurs à fréquence. Les interrupteurs sur la commande murale se situent sur le panneau frontal, sous la plaque. Les interrupteurs sur le ventilateur se situent sur le module de réception placé sur le haut du ventilateur (voir schéma). Les interrupteurs peuvent être réglés sur n'importe quelle position, à condition toutefois que les interrupteurs de l'unité murale et du module de réception soient positionnés sur les mêmes réglages. Tous les modules (RF) et émetteurs sont livrés de l'usine avec les commutateurs DIP réglés en position ON (Marche). Remettez le haut du boîtier du moteur en place (nº 5) à l'aide des quatre vis retirées précédemment. Remarque : Dans le cas où il y aurait plusieurs unités radiocommandées dans une zone, des commutateurs DIP peuvent être réglés sur différents réglages de façon à ce qu'une unité n'interfère pas avec les autres ventilateurs et ne les mette pas en marche par inadvertance. Figure 1 Haut du boîtier du moteur (nº 5) Boîtier du moteur (nº 5) L-1 HIGH 1 2 3 4 ON Vis de pale (S4) MED. L-2 LOW REVERSE FAN OFF 1 2 3 4 ON 12V BAT. OFF 1 ON 2 3 Figure 2 Vue supérieure ATTENTION : Ne jamais tenir ou soulever le ventilateur par les pales. 4 ON 7 8 Étape 7 Repérez l'assemblage de tige de suspension (n° 2). Desserrez la vis de boule située sur la boule pendante noire pour dégager la goupille de verrouillage. La boule pendante noire glissera vers le bas. Retirez la vis de mise à la terre et le fil de terre vert. Retirez la boule pendante de la tige de suspension et conservez toutes les pièces. Insérez les fils du ventilateur à travers la tige de suspension. Vissez la tige de suspension dans la partie supérieure du boîtier de moteur du ventilateur, en faisant attention à ce que les fils soient complètement passés. Placez la tige de suspension de manière à ce que son trou soit aligné avec celui de l’attelage du moteur. Insérez le boulon de sécurité (S6) dans l’attelage et la tige de suspension et fixez l'écrou. Serrez fermement. Serrez la vis de fixation « A » contre la tige de suspension. Enfoncez le couvre-bride (n° 4) sur l'assemblage de la tige de suspension jusqu'à ce qu'il couvre la bride. Placez la coupelle (3) sur la tige de suspension (n° 2). Replacez la boule pendante. Pour cela, insérez la douille pendante dans la tige de suspension et serrez la vis de fixation « C » dans la boule pendante jusqu'à ce qu'elle pénètre dans la tige de suspension. Trou de vis de fixation fileté Goupille de verrouillage Assemblage de la tige de suspension(2) Étape 8 Fil de terre vert Douille pendante Vis de boule Boule pendante Fil de terre Tige de suspension (n° 2) Vis de boule Coupelle (n° 3) Couvre-bride (n° 4) Boule pendante Fil d'antenne Tige de suspension Boulon et écrou de sécurité (S6) Boîtier du moteur du ventilateur Vis de fixation (C) Vis de fixation (A) Boîtier du moteur (n° 5) AVERTISSEMENT: si vous ne serrez pas complètement la tige de suspension en suivant les instructions des étapes 7 et 8, le ventilateur peut se desserrer et éventuellement tomber. IMPORTANT : le fil d’antenne noir doit être connecté pour que le ventilateur fonctionne. 9 Étape 9 Pour plus de sécurité, attachez le câble de sécurité du ventilateur au crochet en « J » (S7) accroché dans la boîte de sortie. Fixez l'installation en faisant passer la bride (S8) dans le câble de sécurité et dans le crochet en «J». Resserrez fortement la bride. Installez le ventilateur sur le support de montage (n° 1). Faites pivoter le boîtier jusqu'à ce que la boule pendante s’installe dans son réceptacle (vous devriez entendre un déclic). Poutre de soutien Crochet en «J» (S7) Boîte de sortie (A) BOÎTE DE SORTIE Plafond Support de montage (n° 1) Fil de terre vert NOTE: les pièces fournies vous permettront d'installer votre ventilateur à un angle de 35°. Pour toute installation à un angle supérieur à 35°, vous aurez besoin d'un adaptateur d'angle à 45° (consultez votre revendeur). Crochet en « J » (S7) Bride (S8) Câble de sécurité 10 Étape 10 1. Connectez les fils du ventilateur à ceux du plafond : le fil de ventilateur blanc au fil de sortie blanc, le fil noir au fil noir et le fil vert au fil vert. Les connecteurs (S5) sont fournis au cas où vous en auriez besoin. S'il existe un fil bleu supplémentaire, connectez-le au fil noir. (Un kit d’éclairage en option peut être connecté à des interrupteurs muraux). Fil de terre 2. Une fois que les Blanc (neutre) connexions ont Noir (alimentation) été effectuées, tournez les épissures vers le haut et faites rentrer soigneusement le câblage dans la boîte Blanc de sortie. Placez les fils Noir bleus et noirs d'un côté de la boîte et les fils blancs et verts de l'autre côté. Des fils de quatre couleurs différentes sortent du dessus du moteur (y compris le fil de terre). Connecteurs (S5) Fil de terre (vert) Fil de terre de la boîte de sortie Fil de terre de la tige de suspension (vert) NOTE: L'installation du crochet en « J » est une exigence canadienne seulement. Fil de terre du support de montage (vert) AVERTISSEMENT: Pour éviter les incendies, les décharges électriques ou les blessures, branchez le ventilateur sur une boîte de sortie marquée « acceptable for fan support » (prise en charge de ventilateur) et utilisez les vis de montage fournies avec la boîte de sortie. La plupart des boîtes de sortie utilisées avec les dispositifs d'éclairage ne prennent pas en charge les ventilateurs et doivent être éventuellement remplacées. En cas de doute, consultez un électricien qualifié. Fils de connexion Boîte de sortie Fils du ventilateur Noir Noir (Fil chargé du ventilateur) Vert Vert (Fil de terre) Blanc Blanc (Fil neutre) 11 13 Étape 11 Fixez la coupelle (n° 3) au support de montage en insérant les vis (S2) dans ses fentes. Faitesla tourner dans le sens des aiguilles d'une montre pour l'installer. Serrez fortement les vis. Plafond Coupelle (n° 3) Vis (S2) Partie inférieure de la coupelle 12 Étape 12 Installez l'ampoule halogène sur le ventilateur. Insérez fermement l'ampoule dans la douille, comme indiqué sur le schéma. Installez ensuite le verre en l'appliquant sur le ventilateur et en le tournant dans le sens des aiguilles d'une montre jusqu'à ce qu'il soit bien encastré. Instructions de câblage REMARQUE : câblez le ventilateur conformément aux instructions qui l’accompagnent. ATTENTION : pour éviter de faire surchauffer et d’endommager la commande et d’autres appareils, ne pas installer la commande pour contrôler une prise de courant, un éclairage fluorescent, un transformateur ni un appareil à moteur autre que les ventilateurs pour lesquels elle est conçue. Ne l’utilisez qu’ave du fil de cuivre ou enrobé de cuivre. Seuls les dispositifs marqués CO/ALR peuvent être utilisés avec du fil en aluminium. 1. Dénudez 19 mm (3/4 po) de fil de cuivre à l’extrémité des connecteurs de circuits en enlevant l’isolant. Maintenez les extrémités dénudées bien droites. 2. Effectuez les raccordements suivants conformément au schéma de câblage : conducteurs noirs (deux) au fil secteur (sous tension) noir, fil vert de terre au fil de cuivre de la boîte de sortie. Maintenez les extrémité dénudées l’une contre l’autre. Enfoncez fermement les fils dans un connecteur et tournez celui-ci dans le sens horaire jusqu’à ce que le cuivre à nu n’apparaisse plus. Immobilisez le connecteur avec du chatterton. ATTENTION : ne branchez jamais le fil neutre blanc à une commande à interrupteur mural. 3. Assurez-vous qu’une pile est installée correctement dans l’interrupteur. Celui-ci doit déjà en être pourvu mais vérifiez que c’est le cas avant d’installer la plaque de montage (voir le schéma). Remarque : le code de remplacement de la pile est 23 A 12 V. 4. Montez le dispositif au moyen des vis de montage longues (fournies). Installez la plaque murale et serrez les vis du couvercle. 5. Rétablissez l’alimentation au tableau électrique. Charge (fil noir) Pile 12 V 23 A HI Neutre (fil blanc) L-1 MED L-2 LOW REV OFF 1 2 3 4 ON 12V. BATT. SUPER 23A 12V OFF ON UNIPOLAIRE Fil de terre (vert) Ampoule d'halogène Fil secteur sous tension (noir) Neutre (fil blanc) Fil de terre (en cuivre) 14 Connexions électriques Raccordez les fils noirs du ventilateur à celui de la boîte de sortie, puis le fil blanc du ventilateur à celui de la boîte de sortie et le fil vert du conducteur de mise à la terre au circuit d’alimentation (voir la figure A). Utilisez les connecteurs fournis avec le ventilateur. Il ne doit y avoir aucun brin débranché ni connexion desserrée. Faites pivoter les épissures vers le haut et faites soigneusement rentrer tous les fils dans la boîte de sortie. Les interrupteurs muraux utilisés doivent être homologués UL pour pouvoir fonctionner avec un ventilateur de plafond. Instructions d’utilisation Fil de terre Blanc Noir Blanc Vert Blanc Ventilateur et éclairage contrôlés par télécommande ATTENTION : coupez toujours le courant au tableau électrique avant de procéder à tout raccordement de fils. ON/OFF Pour arrêt d’urgence HIGH MEDIUM LOW Commande la vitesse du moteur du ventilateur. Pour choisir la vitesse désirée, appuyez une fois sur le bouton et relâchez-le. REVERSE Commande le sens de rotation des pales du ventilateur. Pour inverser le sens de rotation des pales, appuyez une fois et relâchez. FAN OFF Arrête le moteur du ventilateur. Appuyez une fois pour arrêter. Pour remettre le moteur en marche, appuyez sur l'un des boutons de vitesse du moteur. L-1 Ne contrôle aucune fonction sur ce ventilateur. L-2 Commande l’allumage/extinction et l’intensité du kit d’éclairage intégré. Appuyez et relâchez pour commander l’allumage/extinction. Maintenez enfoncé pour faire varier l’intensité sur toute sa plage. REMARQUE : Il est possible d’utiliser les boutons «High», «Medium» ou «Low» pour mettre le moteur du ventilateur en marche et de changer la vitesse du ventilateur à tout moment. Accès au boîtier du moteur Pour accéder au boîtier du moteur, retirez les quatre vis situées sur le haut du boîtier du moteur (nº 8). Conservez ces vis. Soulevez le haut du boîtier du moteur et la coupelle décorative le long de la tige. Maintenez ces deux pièces soulevées à l'aide du clip (nº 9) que vous placez en dessous du boîtier en le faisant glisser sur la tige et en serrant la vis. Cela vous permettra d'accéder à la zone de montage des pales. Problèmes fréquents Problème A : Le ventilateur ne démarre pas Solution : 1. Vérifiez les fusibles ou le disjoncteur et remplacez-les si besoin est. 2. Coupez l'alimentation électrique et vérifiez tous les connecteurs. 3. Vérifiez les interrupteurs on/off ainsi que l'interrupteur de commande mural. Consultez le mode d'emploi. Problème B : Le ventilateur fait trop de bruit Solution : 1. Vérifiez que toutes les vis du ventilateur sont serrées et correctement installées 2. Assurez-vous que le support de montage est correctement installé. 3. Assurez-vous que le kit d’éclairage et le verre ont été correctement réinstallés et fixés. 4. Si vous utilisez une commande murale, assurez-vous qu'il ne s'agit pas d'un transformateur ou d'une commande à vitesse variable. Problème C : Le ventilateur oscille Solution : 1. Vérifiez que toutes les pales sont correctement vissées sur les supports de pales. 2. Vérifiez que tous les supports de pales sont vissés fermement sur le moteur. 3. Vérifiez le poids des pales. Toutes nos pales sont pesées sur des balances électroniques. Le poids est marqué sur le dos de la pale, à côté de l'extrémité du moteur. Toutes les pales doivent avoir le même poids pour que le ventilateur n’oscille pas. 4. Un kit d'équilibrage des pales est fourni avec l'appareil. Poids: un ventilateur complet, c'est-à-dire avec le matériel d'assemblage, pèse 36 lbs. (16.3 kg). Clip de maintien du boîtier (nº 9)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Craftmade Quest CQ52 Installation Instructions Manual

Categoría
Ventiladores domésticos
Tipo
Installation Instructions Manual

En otros idiomas