Roca VICTORIA 20/20 Operating, Cleaning And Maintenance Instructions

Tipo
Operating, Cleaning And Maintenance Instructions
VICTORIA 20, VICTORIA 20/20,
VICTORIA 20 F, VICTORIA 20/20 F, VICTORIA 20/20 T
VICTORIA 20/20 c, VICTORIA 20/20 Fc
Caldera mural de gas
Instrucciones de Funcionamiento
Limpieza y Mantenimiento
para el USUARIO
GB
PT
IT
DE
FR
ES
Wall-mounted gas boiler
Operating, Cleaning and
Maintenance Instructions
for the USER
Chaudière murale à gaz
Instructions de Fonctionnement,
de Nettoyage et Maintenance
pour l’UTILISATEUR
Gasbetriebener Wandheizkessel
Betriebs-, Reinigungs-
und Wartungsanleitung
für den BENUTZER
Caldaie a gas da parete
Istruzioni di Funzionamento,
Pulizia e Manutenzione
per l’UTENTE
Caldeira mural de gás
Instruções de Funcionamento,
Limpeza e Manutenção
para o UTILIZADOR
VICTORIA 20 F
VICTORIA 20/20 F
VICTORIA 20/20 Fc
VICTORIA 20/20 T
VICTORIA 20
VICTORIA 20/20
VICTORIA 20/20 c
ATC ROC
2
GB
PT
IT
DE
FR
ES
Características principales
Victoria 20: Caldera con servicio de Calefacción. La
combustión se produce en una cámara abierta,
aportándose el aire necesario del propio local donde
esté la caldera.
Victoria 20 F: Caldera con servicio único de Calefacción.
La combustión es ajena al ambiente del local donde se
realiza (cámara estanca). El aire necesario se introduce
directamente desde el exterior al mismo tiempo que son
evacuados, por un extractor, los gases producidos.
Victoria 20/20 y 20/20c: Caldera con servicio de
Calefacción y Agua Caliente Sanitaria Instantánea. La
combustión se produce en una cámara abierta,
aportándose el aire necesario del propio local donde
esté la caldera.
Victoria 20/20T: Caldera con servicio de Calefacción y
Agua Caliente Sanitaria Instantánea. La combustión se
produce en una cámara abierta, aportándose el aire necesario
del propio local donde esté la caldera. Los gases producidos
son evacuados al exterior por un extractor.
Victoria 20/20F y 20/20Fc: Caldera con servicio de
Calefacción y Agua Caliente Sanitaria Instantánea. La
combustión es ajena al ambiente del local donde se
realiza (cámara estanca). El aire necesario se introduce
directamente desde el exterior al mismo tiempo que son
evacuados, por un extractor, los gases producidos.
Servicio de Calefacción
Potencia útil: Regulable de 7000 a 20000 kcal/h.
Presión máxima: 3 bar
Temperatura máxima: 90 °C
Presión de llenado: 1,5 bar
Servicio de Agua Caliente Sanitaria
Potencia útil: Regulable de 7000 a 20000 kcal/h.
Presión máxima: 7 bar
Temperatura máxima: 60 °C
Producción : t 25 °C 13,3 l/min.
t 30 °C 11,1 l/min.
t 35 °C 9,5 l/min.
Presión y caudal mínimos para el encendido: 0,2 bar y
3 l/min.
Principalaux caractéristiques
Victoria 20: Chaudière avec service de Chauffage. La
combustion se produit en chambre ouverte, le local dans
lequel est située la chaudière lui apportant l’air nécessaire.
Victoria 20 F: Chaudière à service unique de Chauffage.
La combustion se produit hors de l’atmosphère est
étrangère à l’environnement du local où la chaudière est
installéeelle se réalise (chambre étanche). L’air
nécessaire à la combustion est directement aspiré
s’introduit directement de l’extérieur, les gaz produits
étant en même temps évacués par un extracteur.
Victoria 20/20 et 20/20c: Chaudière avec services de
Chauffage et d’Eau Chaude Sanitaire Instantanée. La
combustion se produit en chambre ouverte, le local dans
lequel est située la chaudière lui apportant l’air nécessaire.
Victoria 20/20T: Chaudière avec service de Chauffage
et d’Eau Chaude Sanitaire Instantanée. La combustion
se produit en chambre ouverte, le local dans lequel est
située la chaudière lui apportant l’air nécessaire. Les
gaz qui se sont produits sont évacués à l’extérieur par
un extracteur.
Victoria 20/20F et 20/20Fc: Chaudière avec service de
Chauffage et d’Eau Chaude Sanitaire Instantanée. La
combustion ne s’effectue pas avec l’air du local où elle
se produit (chambre étanche). L’air nécessaire s’introduit
directement de l’extérieur et les gaz produits sont évacués
en même temps par un extracteur.
Service de Chauffage
Puissance utile: réglable de 7000 à 20000 kcal/h
Pression maximale: 3 bar
Température maximale: 90 °C
Pression de remplissage:1,5 bar
Service d’Eau Chaude Sanitaire
Puissance utile: réglable de 7000 à 20000 kcal/h
Pression maximale: 7 bar
Température maximale: 60 °C
Production t 25 °C 13,3 l/min.
t 30 °C 11,1 l/min.
t 35 °C 9,5 l/min.
Pression et débits minimum pour l’allumage: 0,2 bar et
3 l/min
Caratteristiche principali
Victoria 20: Caldaia con servizio di Riscaldamento. La
combustione si produce in una camera aperta in cui l’aria
necessaria viene apportata dallo stesso locale in cui si
trova la caldaia.
Victoria 20 F: Caldaia con servizio unico di
Riscaldamento. La combustione è estranea all’ambiente
del locale in cui si effettua (camera stagna). L’aria
necessaria è introdotta direttamente dall’esterno
contemporaneamente all’espulsione dei gas prodotti
tramite un estrattore.
Victoria 20/20 e 20/20c: Caldaia con servizio di
Riscaldamento e Acqua Calda Sanitaria Istantanea. La
combustione si produce in una camera aperta in cui l’aria
necessaria viene apportata dallo stesso locale in cui si
trova la caldaia.
Victoria 20/20T: Caldaia con servizio di Riscaldamento e
Acqua Calda Sanitaria Istantanea. La combustione si
produce in una camera aperta in cui l’aria necessaria
viene apportata dallo stesso locale in cui si trova la caldaia.
I gas prodotti vengono inviati all’esterno da un aspiratore.
Victoria 20/20F e 20/20Fc: Caldaia con servizio di
Riscaldamento e Acqua Calda Sanitaria Istantanea. La
combustione si produce in una camera stagna, quindi
senza comunicazione con l’ambiente del locale in cui si
realizza. L’aria necessaria viene introdotta direttamente
dall’esterno e contemporaneamente i gas prodotti
vengono inviati all’esterno da un aspiratore.
Riscaldamento
Potenza utile: regolabile da 7000 a 20000 kcal/h
Pressione massima: 3 bar
Temperatura massima: 90 °C
Pressione di riempimento: 1,5 bar
Produzione di Acqua Calda Sanitaria
Potenza utile: regolabile da 7000 a 20000 kcal/h
Pressione massima: 7 bar
Temperatura massima: 60 °C
Produzione: t 25 °C 13,3 l/min.
t 30 °C 11,1 l/min.
t 35 °C 9,5 l/min.
Pressione e portata minimi per l’accensione: 0,2 bar e
3 l/min.
Hauptmerkmale
Victoria 20: Heizkessel für Heizungsbetrieb. Die
Verbrennung findet in einer offenen Kammer statt, d.h.
die erforderliche Luft wird direkt vom Aufstellungsort
zugeführt.
Victoria 20 F: Heizkessel nur für Heizbetrieb. Die
Verbrennung ist von der Umgebung des Raums, in dem
der Kessel installiert ist getrennt (geschlossene
Brennkammer). Die erforderliche Luft wird direkt von außen
zugeführt, und die entstehenden Gase werden
gleichzeitig über einen Abzug ausgeleitet.
Victoria 20/20 und 20/20c: Heizkessel für
Heizungsbetrieb und Heißwasser-Sofortbereitung. Die
Verbrennung findet in einer offenen Kammer statt, d.h.
die erforderliche Luft wird direkt vom Aufstellungsort
zugeführt.
Victoria 20/20T: Heizkessel für Heizungsbetrieb und
Heißwasser-Sofortbereitung. Die Verbrennung findet in
einer offenen Kammer statt, d.h. die erforderliche Luft
wird direkt vom Aufstellungsort zugeführt. Die
entstehenden Rauchgase werden mittels eines Abzugs
nach draußen geleitet.
Victoria 20/20F und 20/20Fc: Heizkessel für Heizungs-
und Warmwasserbetrieb. Die Verbrennung findet ohne
Kontakt zur Raumluft statt (dichte Brennkammer). Die
erforderliche Luft wird von draußen zugeführt, die
entstehenden Rauchgase werden mittels eines Abzugs
nach draußen geleitet.
Heizungsbetrieb
Nutzleistung: einstellbar von 7000 bis 20000 kcal/h
Höchstdruck: 3 bar
Höchsttemperatur: 90 °C
Fülldruck: 1,5 bar
Heißwasserbetrieb
Nutzleistung: einstellbar von 7000 bis 20000 kcalh
Höchstdruck: 7 bar
Höchsttemperatur: 60 °C
Produktion: t 25 °C 13,3 l/min.
t 30 °C 11,1 l/min.
t 35 °C 9,5 l/min.
Zum Zünden erforderlicher Mindestdruck 0,2 bar,
Mindestdurchflussmenge 3 l/min.
Características principais
Victoria 20: Caldeira de um só serviço. A combustão
produz-se numa câmara aberta, o ar comburente
necessário provém do próprio local onde a caldeira está
instalada.
Victoria 20 F: Caldeira com serviço único de Aquecimento.
A combustão é alheia ao ambiente do local onde é
realizada (câmara estanque). O ar necessário é introduzido
directamente do exterior e os gases produzidos são
evacuados simultaneamente através de um exaustor.
Victoria 20/20 e 20/20c: Caldeira com serviço de
Aquecimento Central e Água Quente Sanitária
Instantânea. A combustão produz-se numa câmara
aberta, o ar comburente necessário provém do próprio
local onde a caldeira está instalada.
Victoria 20/20T: Caldeira com serviço de Aquecimento
Central e Água Quente Sanitária Instantânea. A
combustão produz-se numa câmara aberta, o ar
comburente necessário provém do próprio local onde a
caldeira está instalada. Os gases da combustão são
evacuados para o exterior por um extractor.
Victoria 20/20F e 20/20Fc: Caldeira com serviço de
Aquecimento Central e Água Quente Sanitária
Instantânea. A combustão é alheia ao ambiente dolocal
onde se realiza (câmara estanque). Um extractor
encarrega-se de, simultaneamente, introduzir o ar
comburente directamente do exterior e de evacuar os
gases produzidos pela combustão.
Serviço de Aquecimento
Potência útil: Regulável de 7000 a 20000 Kcal/h.
Pressão máxima: 3 bar.
Temperatura máxima: 90 °C.
Pressão de enchimento: 1,5 bar.
Serviço de Água Quente Sanitária
Potência útil: Regulável de 7000 a 20000 Kcal/h.
Pressão máxima: 7 bar.
Temperatura máxima: 60 °C.
Produção: t 25 °C 13,3 l/min.
t 30 °C 11,1 l/min.
t 35 °C 9,5 l/min.
Pressão e caudal mínimos para o acendimento: 0,2 bar
e 3 l/min.
Main features
Victoria 20: Boiler for Central Heating. Combustion takes
place in an open chamber and the air required is taken
from the boiler room itself.
Victoria 20 F: Boiler for Central Heating only. Combustion
is independent of the room where it is located (room-
sealed). The air required for combustion is drawn directly
from outside as flue gases are removed by an induced
draught fan.
Victoria 20/20 and 20/20c: Boiler for Central Heating
and Instantaneous Domestic Hot Water production.
Combustion takes place in an open chamber and the air
required is taken from the boiler room itself.
Victoria 20/20T: Boiler for Central Heating and
Instantaneous Domestic Hot Water production.
Combustion takes place in an open chamber and the air
required is taken from the boiler room itself. The flue
gases are removed by an induced draught fan.
Victoria 20/20F and 20/20Fc: Boiler for Central Heating
and Instantaneous Domestic Hot Water production.
Combustion is independent of the room where it is located
(room-sealed). The air required for combustion is drawn
directly from outside as flue gases are removed by an
induced draught fan.
Central Heating Mode
Heat Output: Adjustable from 7,000 kcal/h to 20,000
kcal/h.
Maximum circuit pressure: 3 bar
Maximum working temperature: 90 °C
Filling pressure: 1.5 bar
Domestic Hot Water (DHW) Mode
Heat Output: Adjustable from 7,000 kcal/h to 20,000
kcal/h.
Maximum circuit pressure: 7 bar
Maximum working temperature: 60 °C
DHW production: t 25 °C 13.3 l/min.
t 30 °C 11.1 l/min.
t 35 °C 9.5 l/min.
Minimum operating pressure and flow rate for ignition:
0.2 bar and 3 l/min.
ATC ROC
3
Cuadros de Control / Control Panels / Tableaux de contrôle
Schalttafeln / Quadro comandi / Quadros de controle
Conexiones hidráulicas / Water connections / Raccords hydrauliques
Wasseranschlüsse / Collegamenti idraulici / Ligações Hidráulicas
Selector temp. A.C.S. / DHW Temp. Control Knob
Sélecteur temp. E.C.S. / Temperaturwahlschalter Heißwasser
Selettore temperatura A.C.S. / Selector temp. AQS
Leds indicadores; servicio tensión y anomalía
Indicator LEDs: service, power, fault
LEDs indiatión service, tension et anomalie
Leuchtanzeigen: Betrieb, Spannung und Störung
Led indicanti funzionamento, tensione e anomalia
Leds indicadores: serviço, corrente e anomalia
Manómetro analógico
Mechanical pressure gauge
Manomètre analogique
Analoges manometer
Manometro analogio
Manómetro analógico
Selector de velocidades circulador
Pump speed control
Sélecteur vitesses circulateur
Wahlschalter Umwälzgeschwindigkeit
Selettore velocità pompa di circolazione
Selector de velocidades do circulador
Selector temperatura calefacción /CH Temp. Control Knob
Sélecteur temp. Chauffage / Leuchtanziegen Heizgungstemperatur
Selettore temperatura Riscaldamento /Selector de temperatura do Aquecimento
Central
VICTORIA 20/20 - VICTORIA 20/20 F - VICTORIA 20/20 T
VICTORIA 20/20 c - VICTORIA 20/20 Fc
VICTORIA 20
VICTORIA 20 F
Conmutador de servicio
Service Selector Switch
Commutateur de service
Betriebsschalter
Commutatore di funzionamento
Comutador de serviço
Leds temperatura calefacción y anomalías/ Central Heating temp. Leds and fault codes
Leds température du chauffage et codes d'anomalie/ Leuchtanzeigen Temperatur Heikreislauf und Störungscodes
Leds temperatura Riscaldamento e codici anomalia / Leds temperatura Aquecimiento Central e código de anomalias
1 Soupape de sécurité
2 Retour de Chauffage
3 Entrée d'Eau Froide Sanitaire
4 Entrée de gaz
5 Sortie Eau Chaude Sanitaire
6 Aller de Chauffage
7 Robinet Remplisage circuit de Chauffage
8 Robinet vidange circuit de Chauffage
9 Filtre
1 Safety valve (pressure relief)
2 – Central Heating Return Valve
3 – Cold water inlet
4 – Gas inlet cock
5 – DHW outlet
6 – Central Heating Flow Valve
7 – Heating Circuit Fill Valve
8 – Heating Circuit Drain Valve
9 – Filter
1 Válvula de seguridad
2 Retorno de Calefacción
3 Entrada de Agua Fría Sanitaria
4 Entrada de gas
5 Salida Agua Caliente Sanitaria
6 Ida de Calefacción
7 Grifo Llenado circuito Calefacción
8 Grifo vaciado y purgado circuito
Calefacción
9 Filtro
1 Sicherheitsthermostat
2 Rücklauf Heizung
3 Einlauf Kaltwasser
4 Gaszufürhrung
5 Auslauf Heißwasser
6 Vorlauf Heizung
7 Füllhahn Heizungskreislauf
8 Ablasshahn Heizungskreislauf
9 Filter
7
9
8
1 Valvola di sicurezza
2 Ritorno del Riscaldamento
3 Entrata di Acqua Fredda Sanitaria
4 Entrata di gas
5 Uscita Acqua Calda Sanitaria
6 Andata del riscaldamento
7 Rubinetto Riempimento circuito
Riscaldamento
8 Rubinetto Svuotamento circuito
Riscaldamento
9 Filtro
1 Válvula de segurança
2 Retorno do Aquecimento Central
3 Entrada de Água Fria Sanitária
4 Entrada de gás
5 Saída de Água Quente Sanitária
6 Ida ao Aquecimento Central
7 Torneira de enchimento do circuito de
Aquecimento Central
8 Torneira de esgoto do circuito de
Aquecimento central
9 Filtro
1
2
5
6
3
4
IT
FRES GB
PT
DE
ATC ROC
4
1.2
1.1
1.2
1.1
Calefacción y Agua Caliente Sanitaria / Central Heating and Domestic Hot Water
Chauffage et Eau Chaude Sanitaire / Heizung und Heßwasser
Riscaldamento e Acqua Calda Sanitaria / Aquecimento e Água Quente Sanitária
Calefacción / Central Heating / Chauffage
Heizung / Riscaldamento / Aquecimento
Seleccionar la temperatura deseada
Set the desired temperature
Sélectionner la température voulue
Die gewünschte Temperatur einstellen
Selezionare la temperatura desiderata
Colocar a temperatura desejada
1
2 3
1
2
3
Puesta en marcha / Start-up / Mise en marche / Inbetriebnahme / Avviamento / Arranque
Conectar / Plug in
Connecter / Anschließen
Collegare / Ligar
Debe estar entre 1 y 2 bar
Must be between 1 and 2 bar
Devez être entre 1 et 2 bar
Sie zwischen 1 und 2 bar
Deva essere trail 1 e il 2 bar
Teuha que estar entre 1 e 2 bar
Debe estar encendido / Must be "on"
Doit être allumíné / Muß leuchten
Deve essere accesa / Deve estar aceso
Si (<1bar) Llenar hasta 1,5 bar y cerrarlo bien
It To fill up to 1,5 bar and close it well
Si Reuplir 1,5 bar et le fermer biem
Wenn 1,5 bar vollzufüllen und es gut zu schließen
Se Riempire su a 1,5 bar e chiuderlo bene
Se enchen até 1,5 bar e fecharn benn ist
Girar
Tu r n
Tourner
Bewegung
Girare
Girar
Importante: La caldera no se pondrá en marcha si el
termostato de ambiente (opcional) colocado en la
instalación, no está en posición de demanda.
Important: The boiler will not start operating unless the
room thermostat (optional) in the system is on demand.
Important: La chaudière ne se mettra en marche que
si le thermostat d’ambiance (en option) installé n’est
pas en position de demande.
Wichtig: Der Heizkessel springt nicht an, wenn der
(optionale) Raumthermostat der Anlage keinen
Heizbedarf meldet.
Importante: La caldaia non si avvierà se il termostato
ambiente (optional) dell'impianto non si trova in posizione
di richiesta.
Importante: A caldeira não entrará em funcionamento
se o termostato ambiente (opcional) não estiver a pedir
o funcionamento da caldeira.
1 2
3
Agua Caliente Sanitaria / Domestic Hot Water
Eau Chaude Sanitaire / Heizung und Heißwasser
Acqua Calda Sanitaria / Água Quente Sanitária
230V - 50Hz
ATC ROC
5
Sólo Agua Caliente Sanitaria / Domestic Hot Water only / Seulement Eau Chaude Sanitaire
Nur Heißwasser / Solo Acqua Calda Sanitaria / Só Água Quente Sanitária
Paro / Stop / Arrêt / Stopp / Spento / Paragem
En esta posición se activa la vigilancia
antiheladas (ver apartado "Seguridades"). Para
reanudar el servicio, gire de nuevo el
conmutador.
The anti-freeze protection is enabled in this
position (see “Safeties” section). To restore the
service, turn the control knob again.
Dans cette position, un dispositif de surveillance
antigel s'active (voir paragraphe "Sécurité"). Pour
remettre le service en marche, tourner de
nouveau le commutateur.
1
1.1
1.2
2 3
Seguridades / Safeties /Sécurités /Sicherheitsfunktionen / Dispositivi di sicureza / Seguranças
In dieser Position wird eine Frostschutzfunktion
aktiviert (siehe Abschnitt «permanente
Überwachung»). Um den Betrieb wieder
aufzunehmen, stellen Sie den Schalter
entsprechend ein.
La caldaia si arresta e si attiva una vigilanza
antigelate (vedere paragrafo “Vigilanza
permanente”). Per riprendere il funzionamento,
ruotare di nuovo il commutatore.
Nesta posição activa-se uma vigilância
anticongelamento (ver parágrafo “Vigilância
Permanente”). Para repôr a caldeira em serviço
Antiträgheitsvorrichtung: Nach jedem Betrieb
läuft die Umlaufpumpe einige Sekunden nach.
Wenn der Schalter in Position steht , sind
folgende Sicherheitsvorrichtungen aktiv:
Antiblockiervorrichtung: Die Umlaufpumpe
dreht etwa alle 6 Stunden 5 Sekunden lang.
Frostschutz: Wenn die Temperatur in der
Heizung auf 7 °C sinkt, wird die Umlaufpumpe
aktiviert. Sie läuft so lange, bis 9 °C erreicht sind.
Superfrostschutz: Wenn die Temperatur in der
Heizung auf 5 °C sinkt, wird die Umlaufpumpe
aktiviert und der Heizkessel wird auf der
niedrigsten Stufe eingeschaltet und läuft, bis 35°C
erreicht sind, längstens jedoch 30 Minuten.
Wichtig: Wenn der Heizkessel von der
Stromversorgung getrennt ist, ist die ständige
Überwachung nicht aktiv. In diesem Fall ist es zur
Vermeidung von Frostschäden ratsam, das
Wasser aus der Anlage abzulassen.
IT
FR
ES
GB
PT
DE
Antiinercias: Después de cada servicio el
circulador funcionará unos segundos.
Dejando el conmutador en la posición , se
dispondrá de las siguientes seguridades:
Antibloqueo: El circulador girará 15 segundos
cada 6 horas aproximadamente.
Antiheladas: Si la temperatura de la calefacción
baja a 7 °C, se activa el circulador hasta que se
alcancen los 9 °C.
Super antiheladas: Si la temperatura de la cale-
facción baja a 5 °C, se activa el circulador y se
enciende la caldera a la mínima potencia, hasta
alcanzar los 35 °C o durante 30 minutos, lo que
antes ocurra.
Importante: Si la caldera no está alimentada
eléctricamente, la vigilancia permanente no esta-
rá activada. En este caso, para evitar el riesgo de
heladas en la caldera, recomendamos que se
vacíe.
Anti-inertia: Following every service the pump
will run for a short time.
Leaving the selector switch in the position
marked, the following safeties will be available:
Anti-lockout: The pump will run for 15 seconds
every 6 hours.
Anti-freeze protection: If the temperature of
the Heating Circuit drops to 7 °C, the pump will
be turned ON until it rises to 9 °C.
Super anti-freeze protection: If the tem-perature
of the Heating Circuit drops to 5 °C, the pump will
be turned ON and the boiler will operate at
minimum output. The boiler will be switched off
after 30 minutes or when the temperature rises to
35 °C, whichever happens first.
Important: Unless the boiler receives electrical
supply, these safeties will not be activated. In this
case, the boiler should be emptied to avoid the
risk of freezing.
Anti-inerties: Après chaque service, le circula-
teur fonctionnera pendant quelques secondes.
En laissant le commutatur dans la position on
disposera des dispositifs de sécurité suivants:
Antiblocage: Le circulateur torunera 15
secondes environ chaque 6 heures.
Antigel: Si la température du chauffage descend
à 7 °C, le circulateur s'active jusqu'à ce que la
température atteitne 9 °C.
Super antigel: Si la température descend à 5°C,
le circulateur s'active et la chaudière se met en
marche à la puissance maximale jusqu'à atteindre
35 °C ou bien pedant 30 minutes, en fonction de
ce qui se produira en premier.
Important: Si la chaudière n'est pas alimentée
électriquement, la surveillance permanente ne
sera pas activée. Dans ce cas, pour éviter le risque
de prise en glace dans la chaudière, nous
recommandons de la vider.
Anti-inerzie: Dopo ogni periodo di funzionamen-
to la pompa di circolazione funzionerà per alcuni
secondi.
Lasciando il commutatore in posizione si
avranno a disposizione le seguenti sicurezze:
Antibloccaggio: La pompa di circolazione girerà
per 15 secondi ogni 6 ore circa.
Antigelate: Se la temperatura del riscaldamento
scende a 7 °C, si attiva la pompa di circolazione,
che rimane in funzionamento finché si raggiun-
gano i 9 °C.
Super antigelate: Se la temperatura del
riscaldamento scende a 5 °C, si attiva la pompa
di circolazione e la caldaia si accende alla minima
potenza sino al raggiungimento dei 35 °C o per
30 minuti (il primo che avvenga).
Importante:Se la caldaia non riceve alimentazio-
ne elettrica, la vigilanza permanente non saràatti-
vata. In questo caso, per evitare il rischio di gelate
all’interno della caldaia, consigliamo di vuotarla.
Anti-inércias: Depois de cada serviço o
circulador funcionará alguns segundos.
Deixando o comutador na posição disporá
das seguintes seguranças:
Antibloqueio: O circulador rodará
aproximadamente 15 segundos cada 6 horas.
Anticongelamento: Se a temperatura da água
do circuito de aquecimento central baixar aos
7°C, o circulador entra em funcionamento até que
seja alcançada a temperatura de 9 °C.
Super anticongelamento: Se, apesar da
protecção anterior, a temperatura do circuito de
aquecimento central baixa aos 5 °C, além do
funcionamento do circulador, a caldeira acende-
se na potência mínima até alcançar os 35 °C ou
durante 30 minutos (o que ocorrer primeiro).
Importante: Se a caldeira não estiver alimentada
electricamente, a vigilância permanente não
estará activada.
ATC ROC
6
Limpieza filtro / Cleaning the filter / Nettoyage filtre / Filterreinigung / Pulizia del filtro / Limpeza do filtro
Llave de paso
Shut-off valve
Robinet d'entrée
Absperrhahn
Rubinetto
Torneira de passagem
Limpiarlo
Clean it
Le nettoyer
Reinigen
Pulire
Limpá-lo
3.1 3.2
Códigos anomalías / Fault codes / Codes d'anomalie
Störungscodes / Codici di anomalie / Código de anomalia
Código de anomalía / Fault codes
Codes d'anomalia / Störungsodes
Codici di anomalie / Codes d'anomalia
50 - 60 - 70 - 90
Girar / Turn / Tourner / Bewegung / Girare / Girar
3.1
3.2
1
1.1
1.2
2 3
1 2 3
Abrir / To open / ouvrir
um zu öffnen / per oprire / Abrir
Girar / Turn / Tourner / Bewegung / Girare / Girar
Si se encienden estos pilotos significa que la
caldera está bloqueada por alguna anomalia. Tome
nota de los que se encienden y llame a su instalador
o a nuestro servicio técnico. No obstante, si la
combinación de pilotos que se enciende es alguna
de las siguientes, antes de llamar puede hacer lo
siguiente:
60-70-90 ó 40-80-90: Puede ser que no llegue
gas a la caldera. Verifique si alguna llave de paso
del gas está cerrada. Una vez subsanada la
anomalía, gire el conmutador a la posición R ,
vuelva a girarlo al servicio deseado y la caldera
intentará reanudar el servicio.
40-50-60-70-90: Ha actuado el dispositivo de
evacuación de los gases de la combustión, por
una momentánea inversión de los mismos o una
deficiente salida. Espere unos 15 minutos para la
reposición automática del servicio y luego gire el
conmutador a la posición R , vuelva a girarlo al
servicio deseado y si se repite la anomalía avise al
técnico.
50-60-90: Termostato de sobretemperatura abierto.
Posiblemente hay aire dentro de la instalación o el
circulador está agarrotado. Purgar el aire de la
caldera y de los radiadores (Fig. 4) o desbloquear
el circulador (Fig. 5). Pulsar el rearme manual
instalado dentro de la caldera (Fig. 6/7). Gire el
conmutador a la posición R , vuelva a girarlo al
servicio deseado (Fig. 3).
Si les lampes témoin, s'allument, cella signifie que
la chaudière est bloquée par une anomalie
quelconque. Prendre note de celles qui s'allument
et appeler l'installateur ou notre service technique.
Cependant, si la combinaison de lampes témoin
allumées est l'une des suivantes, avant d'appeler,
on peut porcéder de la façon suivante:
60-70-90 ou 40-80-90: Il est probable que le gaz
n'arrive pas à la chaudière. Vérifier si quelque vanne
de passage du gaz n'est pas fermée. Une fois cette
anomalie corrigée, tourner le commu-tateur vers la
position R , tournez-le enore au service desiré et la
chaudière essaiera de redonner le service.
40-50-60-70-90: Le dispositif d'évacuation des gaz
de la combustion s'est activé à cause d'une
inversion momentanée de ceuxci ou d'une sortie
défectueuse. Attendre environ 15 minutes pour la
remise en service automatique et tourner ensuite
le commutateur vers la position R , tournez-le
enore au service desiré et si l' anomalie se
reproduit, prévenir le technicien.
50-60-90:Thermostat de sécurité de surchauffe
ouvert. Il se peut qu’il y ait de l’air dans l’installation
ou que le circulateur soit bloqué. Purger l’air de la
chaudière et des radiateurs (Fig. 4) ou débloquer
le circulateur (Fig. 5). Appuyer sur l’allumage manuel
installé dans la chaudière (Fig. 6/7). Tourner ensuite
le commutateur vers la position R , tournez-le
enore au service desiré (Fig. 3).
If indicator lamps and light up, it means that the
boiler has “locked out” on a fault. Please take note of
the lamps that light up and call your installer or
Roca’s nearest After-Sales Service. However, if the
lamps that light up are as indicated below, before
calling you may try to rectify the faulty condition yourself
as follows:
60-70-90 or 40-80-90: This means that burners fail to
light up due to the lack of gas. Check if any of the gas
inlet cocks is closed. Once the fault has been cleared,
turn the service selector switch to the position marked
R , rotate it to the wanted service again and then the
boiler will attempt to light up again.
40-50-60-70-90: This means that the evacuation
control device for the products of combustion has
been activated due to a momentary backflow or
irregular outlet of flue gases. Wait about 15 minutes
for an automatic resumption of the service
concerned and then turn the service selector switch
to the position marked R , rotate it to the wanted
service again and if this happens again, call your
nearest After-Sales Service office.
50-60-90:Overheating thermostat open. There may
be air in the system or the pump may be jammed.
Bleed the air from the boiler and radiators (Fig. 4)
or unblock the pump (Fig. 5). Press the manual
reset button installed in the boiler (Fig. 6/7). turn
the service selector switch to the position marked
R , rotate it to the wanted service again (Fig. 3).
FR
ES
GB
Mantenimiento / Maintenance / Maintenance / Wartung / Manutenzione / Manutenção
Debe ser realizado una vez al año como mínimo y
por personal técnico cualificado. Recomendamos
verificar aspectos de seguridad (análisis de
combustión), consumos, evacuación de gases y
ventilación necesaria.
Mindestens einmal jährlich und durch qualifiziertes
Fachpersonal. Empfohlen wird die Überprüfung der
Siecherheitsfunktionen (Verbrennung-sanalyse),
des Verbrauchs, des Rauchabzugs und der
erforderlichen Belüftung.
Debe ser ralizado una vez al año como mínimo y
por personal técnico cualificado. Recomendamos
verificar aspectos de seguridad (análisis de
combustión), consumos, evacuación de gases y
ventilación necesaria.
Must be performed at least once a year by a
qualified service engineer. It is advisable that
aspects regarding safety (flue gas analysis),
consumption, removal of flue gases and ventilation
be checked.
Deve essere effettuata da un tecnico qualificato
almeno una volta l’anno. Consigliamo di controllare
aspetti di sicurezza (analisi della combustione),
consumo, uscita dei gas e ventilazione necessaria.
Elle doit être effectuée au moins une fois par an et par
un personnel technique qualifié. Nous recommandons
de vérifier les aspects concernant la sécurité (analyse
de combustion), les consommations, l’évacuation de
gaz et la ventilation nécessaire.
ES
GB
FR
IT PTDE
ATC ROC
7
Se os pilotos se acendem significa que a caldeira
se encontra bloqueada por anomalia. Tome nota
dos que se encontram acesos e chame o seu
instalador ou o serviço de Assistência Técnica a
Clientes Roca. Não obstante, antes de ligar,
verifique se a combinação de pilotos que se
acende coincide com alguma das seguintes:
60-70-90 ou 40-80-90: Pode ser que não chegue
gás à caldeira. Verifique que as torneiras de
passagem de gás não se encontram fechadas.
Uma vez resolvida a anomalia, rode o comutador
para a posição R , gire novamente para o serviço
querido e se a caldeira tentará repôr o serviço.
40-50-60-70-90: O dispositivo de evacuação de
gases da combustão actuou por motivo de uma
inversão momentânea dos mesmos ou por saída
deficiente. Espere cerca de 15 minutos e rode o
comutador para a posição R ,gire novamente para
o serviço querido e se a anomalia persistir avise o
técnico.
50-60-90: Termóstato de sobreaquecimento
aberto. Possivelmente existe ar no interior da
instalação ou o circulador está bloqueado. Purgar
o ar da caldeira e dos radiadores (Fig 4) ou
desbloquear o circulador (Fig. 5). Premir o
rearmamento manual instalado no interior da
caldeira (Fig. 6/7). Rode o comutador para a posição
R ,gire novamente para o serviço querido (Fig. 3).
IT PTDE
Se si accendono le spie significa che la caldaia è
bloccata da qualche anomalia. Prendere nota delle
spie che si accendono e rivolgersi al proprio
Installatore di fiducia o al nostro Servizio di
Assistenza Tecnica. Ciononostante, se la sequenza
di spie che si accende è la seguente, prima di
rivolgersi a un tecnico fare quanto segue:
60-70-90 o 40-80-90: Può darsi che non giunga
gas alla caldaia. Controllare se qualche rubinetto
del gas è chiuso. Una volta eliminata l’anomalia,
ruotare il commutatore R , lo routi di nouvo al
servizio ricercato e in posizione e la caldaia
cercherà di rimettersi in funzionamento.
40-50-60-70-90: È scattato il dispositivo di scarico
dei gas della combustione per una momentanea
inversione di questi o per una deficiente fuoriuscita.
Attendere circa 15 minuti per il ripristino automatico
del funzionamento, quindi ruotare il commutatore
R , lo routi di nouvo al servizio ricercato in posizione
e se l’anomalia si ripete, avvisare un tecnico.
50-60-90: Termostato di sovratemperatura aperto.
Eventuale presenza d’aria all’interno dell’impianto
o circolatore bloccato. Sfiatare l’aria dalla caldaia e
dai radiatori (Fig. 4) o sbloccare il circolatore (Fig.5).
Premere il pulsante di ripristino manuale situato
all’interno della caldaia (Fig. 6/7). Ruotare il
commutatore R , lo routi di nouvo al servizio
ricercato in posizione (Fgi. 3).
Wenn die Leuchtanzeigen aufleuchten, bedeutet
dies, dass der Heizkessel aufgrund einer Störung
blockiert ist. Notieren Sie, welche Anzeigen
aufleuchten und setzen Sie sich mit Ihrem
Installateur oder mit unserem Kundendienst in
Verbindung. Wenn allerdings eine der folgenden
Kombinationen aufleuchtet, können Sie das
Problem möglicherweise selbst lösen:
60-70-90 oder 40-80-90: Es kann sein, das der
Heizkessel nicht mit Gas versorgt wird. Überprüfen
Sie, ob irgendein Gashahn geschlossen ist. Öffnen
Sie den Hahn und drehen Sie den Schalter auf
Position R , drehen Sie es wieder zum gewollt
Dienst und der Heizkessel wird daraufhin versuchen,
den Betrieb wieder aufzunehmen.
40-50-60-70-90: Die Abzugsvorrichtung für Rauchgase
hat wegen einer vorübergehenden
Rauchgasumkehrung oder wegen mangelhaften
Abzugs reagiert. Warten Sie etwa 15 Minuten die
automatische Wiederaufnahme des Betriebs ab und
drehen Sie dann den Schalter auf Position R ,drehen
Sie es wieder zum gewollt Dienst und wenn die Störung
wieder auftritt, rufen Sie den Kundendienst.
50-60-90: Der Thermostat für den Überhitzungsschutz
ist geöffnet. Wahrscheinlich befindet sich Luft im
Kreislauf oder die Umwälzpumpe ist blockiert. Der
Kessel und die Heizkörper (Abb. 4) sind zu entlüften
oder die Umwälzpumpe ist gängig zu machen (Abb.5).
Drücken Sie den am Kessel installierten manuellen
Reset-Schalter (Abb. 6/7). Drehen Sie dann den
Schalter auf Position R ,drehen Sie es wieder zum
gewollt Dienst (Abb. 3).
4 5
VICTORIA 20
VICTORIA 20/20
VICTORIA 20/20 T
VICTORIA 20/20 c
VICTORIA 20 F
VICTORIA 20/20 F
VICTORIA 20/2 Fc
6 7
ATC ROC
PT
DE
Empfehlungen
Der Aufdruck der Kontrolltafel ist durch eine Folie
geschützt. Wir empfehlen, diese zu entfernen.
Die Hinweise in dieser Anweisung müssen
beachtet werden.
Für folgende Tätigkeiten sollten die Dienste eines
Fachmanns in Anspruch genommen werden:
Die Inbetriebnahme des Heizkessels
Die erforderlichen Justierungen und
Einstellungen
Die Überprüfung, ob alle geltenden Vorschriften
eingehalten werden.
Rauchgasabzug
Die Heizkessel vom Typ B11BS sind mit einer
Vorrichtung zur Kontrolle des ordnungsgemäßen
Abzugs der Rauchgase ausgestattet. Wenn durch
diese eine Störung des Rauchgasabzugs
festgestellt wird, wird die Gasversorgung
unterbrochen und es erscheint der entsprechende
Störungscode.
Recomendações
Existe uma película transparente que protege a
serigrafia do quadro de controle. Recomendamos
que a retire.
Respeite as advertências contidas nestas Instruções.
É conveniente dispôr dos serviços de um
profissional qualificado para realizar:
O primeiro arranque da caldeira.
Os ajustes e regulações necessárias.
– A verificação de que as normas vigentes são
cumpridas.
Evacuação dos gases da
combustão
As caldeiras do tipo B11BS estão equipadas com
um dspositivo de controle da evacuação dos
produtos da combustão. No caso de que a caldeira
observe uma perturbação na evacuação dos ditos
gases, interrompe a alimentação do combustível
e indica-nos o correspondente código de
anomalia.
IT
Consigli
La serigrafia del quadro comandi è protetta da una
pellicola trasparente. Consigliamo di toglierla.
È necessario rispettare le avvertenze che figurano
in queste istruzioni.
È conveniente rivolgersi a un tecnico specializzato
per:
Effettuare l’avviamento della caldaia
Realizzare le tarature e le regolazioni necessarie
Controllare il rispetto della normativa vigente
Scarico dei gas
Le caldaie tipo B11BS sono dotate di un
dispositivo di controllo dello scarico dei prodotti
della combustione. Se la caldaia rileva
un’anomalia nello scarico dei gas, interromperà
l’alimentazione del gas e apparirà il corrispondente
codice d’anomalia.
EG-Kennzeichnung
Die Gas-Wandheizkessel von Roca
entsprechen der EU-Richtlinie 89/336/EWG
über elektromagnetische Verträglichkeit, der
EU-Richtlinie 90/396/EWG für Gasgeräte, der
Niederspannungsrichtlinie 73/23/EWG sowie
der Leistungsrichtlinie 92/42/EWG.
Marchio CE
Le caldaie a gas da parete Roca soddisfano
le Direttive Europee 89/336/CEE sulla
Compatibilità Elettromagnetica, 90/396/CEE
sugli Apparecchi a Gas, 73/23/CEE sugli
Apparecchi a Bassa Tensione e 92/42/CEE
sul Rendimento.
Marcação CE
As caldeiras murais de gás Roca estão
conformes com a Directiva Europeia
89/336/CEE de Compatibilidade Electro-
magnética , a Directiva Europeia 90/
396/CEE de Aparelhos a Gás, a Directiva
Europeia 73/23/CEE de Baixa Tensão e a
Directiva Europeia 92/42/CEE de
Rendimento.
N-6837-3-0404-CE © Roca Calefacción, S.L., Barcelona 2004
Recomendaciones
Existe un film transparente que protege la
serigrafía del cuadro de control. Recomendamos
retirarlo.
Es necesario respetar las advertencias de estas
Instrucciones.
Es conveniente disponer de los servicios de un
profesional cualificado para realizar:
La puesta en marcha de la caldera
Los ajustes y reglajes necesarios
La verificación de que se cumple la normativa
vigente.
Evacuación de los gases
Las calderas tipo B11BS están equipadas con un
dispositivo de control de evacuación de los
productos de la combustión. En el caso de que la
caldera observe una perturbación en la
evacuación de los gases, interrumpirá la
alimentación de gas y aparecerá el consiguiente
código de anomalía.
FR
ES
Recommandations
Une pellicule transparente protège la sérigraphie
du tableau de contrôle.Nous recommandons de
la retirer.
Il faut respecter les avertissements de ces
Instructions.
Il convient d'avoir recours aux services d'un
professionnel qualifié pour effectuer:
La mise en marche de la chaudière.
Les ajustements et les réglages nécessaires.
La vérification du respect des normes en
vigueur.
Évacuation des gaz
Les chaudières du type B11BS sont munies d'un
dispositif de contrôle de l'evacuation des produits
de combustion. Dans le cas sù la chaudière
observarait une perturbation dans l'évacuation des
gaz, elle interrompra l'alimentation de gaz et le
code d'anomalie correspondant sera affiché.
Marquage CE
Les chaudières murales de gaz Roca sont
conformes à la Directive Européenne
39/336/CEE relative à la Compatibilité
Électromagnétique, à la Directive Européenne
90/396/CEE relative aux Appareils à gaz, à la
Directive Européenne 73/23/CEE relative à
la Basse Tension et à la Directive Européenne
92/42/CEE relative au Rendement.
GB
Recommendations
The peel-off film which protects the control fascia
should be removed.
It is important to observe all the notes and
precautions contained in these Instructions.
It is advisable to call a qualified service engineer
for the following operations:
Boiler start-up
The necessary adjustments and settings·
Verification that current regulations are complied
with.
Flue gas removal
B11BS boilers are equipped with an evacuation
control device for the products of combustion. If
the boiler detects an inadequate removal of flue
gases, the gas supply will be shut off and the
corresponding fault code will be displayed.
Marcado CE
Las calderas murales de gas Roca son con-
formes a la Directiva Europea 89/336/CEE
de Compatibilidad Electromagnética, a la
Directiva Europea 90/396/CEE de Aparatos
de gas, a la Directiva Europea 73/23/CEE de
Baja Tensión y a la Directiva Europea
92/42/CEE de Rendimiento.
CE Marking
Roca wall-mounted boilers comply with the
following European Directives: 89/336/EEC
on Electromagnetic Compatibility, 90/396/EEC
on Gas Appliances, 73/23/EEC on Low
Voltage, and 92/42/EEC on Efficiency.
ATC ROC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Roca VICTORIA 20/20 Operating, Cleaning And Maintenance Instructions

Tipo