Mr. Heater MH170QFAV Manual de usuario

Tipo
Manual de usuario
2017
www.mrheater.com 800-251-0001
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY:
Featuring NEW QUIET BURNER TECHNOLOGY
FORCED AIR PROPANE
CONSTRUCTION HEATER
Force-Air Propane Construction Heater
2
SPECIFICATIONS
Maximum: Minimum:
CONTENTS
WARNING:
WARNING:
CARBON MONOXIDE CAN KILL YOU
WARNING:
GENERAL HAZARD WARNING:
THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNINGS:
WARNING:
WARNING:
GENERAL INFORMATION
1-800-321-0001
Force-Air Propane Construction Heater
3
OPERATING PRECAUTIONS
When the heater is to be operated in the presence
of other people the user is responsible for properly
acquainting those present with the safety precautions
and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
do not
IMPORTANT
Figure 1
Figure 2
MH170QFAVT
Figure 1
Figure 2:
Force-Air Propane Construction Heater
4
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should
smell for the gas odor low to the floor. ANY GAS ODOR
IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
ODOR FADING - NO ODOR DETECTED
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
Always be sensitive to the slightest gas odor.
ATTENTION - CRITICAL POINTS TO
REMEMBER!
Propane (LP) gas has a distinctive odor. Learn to
recognize these odors. (Reference Fuel Gas Odor and
Odor Fading sections above.
Heater Elevation Adjustment
1.
Force-Air Propane Construction Heater
5
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
170QFAVT
START
STOP
RESTART AFTER SAFETY SHUTDOWN
MAINTENANCE AND STORAGE
SERVICING
IMPORTANT
Force-Air Propane Construction Heater
6
170QFAVT - WIRING CHART
COLOR LENGTH FROM TO
HOW MUCH HEAT DO I REQUIRE?
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V Cord Length in Feet
Amps. 25 50 100 150
WARNING:
Cubic feet Temperature Rise Required (
o
F)*
of space to
be heated 20
o
30
o
40
o
50
o
BTU’S PER HOUR REQUIRED
R
B
B
B
B
R
R
B
WIRING DIAGRAM
SIZE AND CAPACITY OF PROPANE
CYLINDERS
Force-Air Propane Construction Heater
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
31
30
29
28
26
27
25
24
23
Item Part No. Description Qty.
Item Part No. Description Qty.
WARNING:
PARTS ORDERING INFORMATION:
PURCHASING:
FOR INFORMATION REGARDING SERVICE
LIMITED WARRANTY
ANSI Z83.7b/CSA 2.14b-2009
OPERATING INSTRUCTIONS
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY:
2017
www.mrheater.com 800-251-0001
AVERTISSEMENT : Le non-respect des instructions, telles qu’indiquées dans le présent guide, risque de
causer une explosion ou un incendie entraînant des dommages matériels ou des blessures graves, voire mortelles.
APPAREIL DE CHAUFFAGE AU PROPANE À AIR
PULSÉ POUR CHANTIER DE CONSTRUCTION
GUIDE D’UTILISATION ET MANUEL DU PROPRIÉTAIRE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :
Doté NOUVELLE TECHNOLOGIE DE BRÛLEUR CALME
Force-Air Propane Construction Heater
2
SPÉCIFICATIONS
..............................................................
Maximum :
Minimum :
° °
° °
TABLE DES MATIÈRES
°
°
°
AVERTISSEMENT :
AVERTISSEMENT :
EL MONOXIDO DE CARBONO PUEDE MATARLO
AVERTISSEMENT :
AVERTISSEMENT GÉNÉRAL
DE DANGER :
L’ÉTAT DE CALIFORNIE EXIGE QUE L’AVERTISSEMENT SUIVANT SOIT FOURNI :
AVERTISSEMENT :
AVERTISSEMENT :
Force-Air Propane Construction Heater
3
PRÉCAUTIONS LIÉES AU FONCTIONNEMENT
Lorsque l’appareil de chauffage doit fonctionner en présence
d’autres personnes, l’utilisateur est responsable d’informer
ces dernières des instructions et précautions liées à la
sécurité et de les avertir des dangers inhérents.
PRÉCAUTIONS LIÉES À LA SÉCURITÉ
n’orientez pas
IMPORTANT :
Figure 1
Figure 2.
170 QFAVT
Figure 2
Figure 1
Force-Air Propane Construction Heater
4
ODEUR DU GAZ COMBUSTIBLE
Des additifs odorants ont été ajoutés au gaz propane liquéfié
et au gaz naturel dans le but de faciliter la détection de fuites.
Vous devriez remarquer une odeur de gaz combustible s’il y
a une fuite. Comme le gaz propane (liquéfié) est plus lourd
que l’air, l’odeur de gaz se détecte plus facilement près du
sol. TOUTE ODEUR DE GAZ EST UN SIGNAL QU’IL FAUT
INTERVENIR IMMÉDIATEMENT !
SUBSTANCE ODORANTE AUCUNE ODEUR
DÉCELÉE
AVERTISSEMENT RELATIF AUX SUBSTANCES ODORANTES
AVERTISSEMENT
Risque d’asphyxie
La substance odorante contenue dans le gaz propane
(liquéfié) et le gaz naturel est incolore et, selon
certaines circonstances, son odeur pourrait s’estomper.
Portez toujours attention à la moindre odeur de gaz.
ATTENTION - POINTS ESSENTIELS À RETENIR !
glage en hauteur de l‘appareil de chauffage
Force-Air Propane Construction Heater
5
INSTRUCTIONS DE FONCTIONNEMENT
AVANT LE FONCTIONNEMENT
170QFAVT
DÉMARRAGE
ARRÊT
REDÉMARRAGE APRÈS UN ARRÊT D’URGENCE
ENTRETIEN ET ENTREPOSAGE
°
ENTREPOSAGE
IMPORTANT :
Force-Air Propane Construction Heater
6
°
°
DE QUELLE QUANTITÉ DE CHALEUR AIS-JE
BESOIN ?
Calibre minimum recommandé pour rallonges
AVERTISSEMENT :
DIMENSIONS ET CONTENANCES DES
BONBONNES DE GAZ PROPANE
BTU PAR HEURE REQUIS
Pieds cubes
d’espace
à chauffer
Élévation de température requise ( C/ F)*
-6,6 C
(20 F)
1,0 C
(30 F)
4,4 C
(40 F)
10 C
(50 F)
Tableau de calibre de câble AWG
Plaque
d’identification
120 V A
Longueur de la rallonge en pieds
25 50 100 150
170QFAVT - SCHÉMA DE CÂBLAGE
COULEUR LONGUEUR DE À
Force-Air Propane Construction Heater
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
31
30
29
28
26
27
25
24
23
Item Part No. Description Qty.
Item Part No. Description Qty.
AVERTISSEMENT :
INFORMATION SUR LA COMMANDE DE PIÈCES :
ACHAT :
POUR OBTENIR DES INFORMATIONS SUR LE SERVICE
GARANTIE LIMITÉE
ANSI Z83.7b-2009/CSA 2.14b-2009
GUIDE D’UTILISATION ET
MANUEL DU PROPRIÉTAIRE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :
2017
www.mrheater.com 800-251-0001
ADVERTENCIA: Si no se siguen al pie de la letra las instrucciones de este manual, poda
producirse un incendio o una explosión que provocaría daños materiales, lesiones o muertes.
INSTRUCCIONES DE USO Y MANUAL DEL USUARIO
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
Con NUEVA TECNOLOGÍA QUEMADOR TRANQUILA
PROPANO AIRE FORZADO
CALENTADOR CONSTRUCCIÓN
Force-Air Propane Construction Heater
2
ESPECIFICACIONES
Máxima: Mínima:
° °
° °
°
CONTENIDOS
ADVERTENCIA:
ADVERTENCIA:
LE MONOXYDE DE CARBONE PEUT VOUS TUER
ADVERTENCIA:
ADVERTENCIA GENERAL DE
PELIGRO:
EL ESTADO DE CALIFORNIA EXIGE LAS SIGUIENTES ADVERTENCIAS:
ADVERTENCIA:
ADVERTENCIA:
Force-Air Propane Construction Heater
3
PRECAUCIONES DE UTILIZACIÓN
Cuando deba utilizarse el calentador en presencia de
otras personas, el usuario será responsable de poner
a los presentes al corriente de las precauciones e
instrucciones de seguridad, y de los posibles peligros.
PRECAUCIONES DE SEGURIDAD
no
IMPORTANTE:
Figura 1
Figura 2
170 QFAVT
Figura 1
Figura 2:
Force-Air Propane Construction Heater
4
OLOR A GAS COMBUSTIBLE
Los gases LP y el gas natural contienen sustancias
aromáticas artificiales -añadidas específicamente para
facilitar la detección de fugas de gas.
Si se produjera una fuga de gas, usted debe poder
oler el gas combustible. Dado que el propano (LP)
es más pesado que el aire, debe tratar de detectar
el olor lo más cerca del piso posible. ¡CUALQUIER
OLOR A GAS SERÁ LA SEÑAL PARA TOMAR MEDIDAS
INMEDIATAMENTE!
DISIPACIÓN DEL OLOR - NO SE DETECTA
NINGÚN OLOR
ADVERTENCIA DE DISIPACIÓN DEL OLOR
ADVERTENCIA
Peligro de asfixia
La sustancia aromática presente en el gas propano (LP)
y en el gas natural es incolora y la intensidad de su olor
puede desvanecerse en algunas circunstancias.
Manténgase siempre alerta al más mínimo olor a gas.
ATENCIÓN - PUNTOS IMPORTANTES PARA
RECORDAR
El gas propano (LP) tiene un olor característico. Aprenda
a reconocer estos olores. (Consulte las secciones “Olor a
gas combustible“ y “Disipación del olor“).
Ajuste de la elevación del calentador
Force-Air Propane Construction Heater
5
INSTRUCCIONES DE USO
PREPARATIVOS PARA EL USO
MH170FAVT
ENCENDIDO
APAGADO
REINICIO LUEGO DEL APAGADO DE
SEGURIDAD
MANTENIMIENTO Y ALMACENAMIENTO
REPARACIÓN
IMPORTANTE:
Force-Air Propane Construction Heater
6
¿CUÁNTO CALOR ES NECESARIO?
Calibre mínimo recomendado
para los cables de extensión
ADVERTENCIA:
TAMAÑO Y CAPACIDAD DE LOS CILINDROS
DE PROPANO
BTU POR HORA NECESARIOS
Pies cúbicos
de espacio
que se
calefacciona
Aumento de temperatura requerido
o
C (
o
F)*
-6,6 C
(20 F)
1,0 C
(30 F)
4,4 C
(40 F)
10 C
(50 F)
Gráfico del calibre del cable CAE
Placa de nombre
120 V Amp.
Longitud del cable en pies
7,6 m
(25 ft)
15,2 m
(50 ft)
30,5 m
(100 ft)
46 m
(150 ft)
170QFAVT: GRÁFICO DE CABLEADO
COLOR LONGITUD DESDE HASTA
Force-Air Propane Construction Heater
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
31
30
29
28
26
27
25
24
23
Item Part No. Description Qty.
Item Part No. Description Qty.
ADVERTENCIA:
INFORMACIÓN PARA ORDENAR REPUESTOS:
COMPRAS:
SI DESEA OBTENER INFORMACIÓN ACERCA DE REPARACIONES
GARANTÍA LIMITADA
ANSI Z83.7b/CSA 2.14b-2009
INSTRUCCIONES DE USO
Y MANUAL DEL USUARIO
LEA CUIDADOSAMENTE LAS INSTRUCCIONES:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Mr. Heater MH170QFAV Manual de usuario

Tipo
Manual de usuario

en otros idiomas