Wavetek 232 Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

TM-SWTM-SW
RS232 Software
and Cable
For use with Meterman Model TMD90,
Digital Thermometer and
Model TMA10, Anemometer
User Manual
Mode d'emploi
• Bedienungshandbuch
• Manuale d'Uso
Manual de uso
U.S. Service Center
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel: 877-596-2680
Fax: 425-446-4882
Canadian Service Center
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, ON L4Z 1X9
Tel: 877-596-2680
Fax: 425-446-4882
European Correspondence Address*
Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
*Correspondence only - no repair or replacement available from this
address. European customers please contact your distributor.
Visit www.metermantesttools.com for
• Catalog
• Application notes
• Product specifications
• Product manuals
PN 2106913
January 2004
© Wavetek Meterman Test Tools.
All rights reserved. Printed in Taiwan.
Please Recycle
®
®
®
®
1
TM-SW Interface Software
Contents
Introduction .......................................................................................................................................................2
TM-SW Features ................................................................................................................................................2
Package Contents ...........................................................................................................................................2
Installation .........................................................................................................................................................2
Hardware Requirements .................................................................................................................................2
Installing TM-SW Software.............................................................................................................................2
Using the TM-SW Software...............................................................................................................................3
Starting the Software......................................................................................................................................3
Retrieving a File ..............................................................................................................................................4
Saving a File....................................................................................................................................................4
Setting Up the COM Port ................................................................................................................................5
Viewing Statistics............................................................................................................................................5
Printing a Graph..............................................................................................................................................6
Controlling the Logger Session .........................................................................................................................6
Logger Setting ................................................................................................................................................6
Recording........................................................................................................................................................7
YOFFSET and YGAIN.......................................................................................................................................7
Setting the Alarm Limit...................................................................................................................................7
Display Range.................................................................................................................................................8
Customer Support..............................................................................................................................................8
English
2
Introduction
The TM-SW software and RS-232 cable is used with the TMD90 Thermometer and TMA10 Anemometer for real time data
acquisition of your measurement results. You can store the data on your computer for further analysis, data reporting, or
charting.
TM-SW Features
Up to 16,000 sample readings with real-time date and time-stamp.
Programmable sample interval from 1 to 3,600 seconds.
User-defined maximum (High) and minimum alarm (Low) settings.
Allow further analysis by downloading data to a computer program.
To assist with data analysis and process control, all data is saved in text format (.txt) and can be easily transformed
for use by other software applications.
Package Contents
CD-ROM
RS-232 cable with Sub-D connector
User-Manual
Installation
Hardware Requirements
Windows 95/98/NT/2000//ME/XP operating systems with a COM1 or COM2 serial port.
Installing TM-SW Software
1. Insert the CD into your CD-ROM drive.
2. Click the Install Software button on the TM-SW menu.
3. Follow the installation instructions that appear on the screen.
3
Using the TM-SW Software
Starting the Software
1. Insert the RS-232 connector in the meter and connect the cable to the COM port on your PC.
2. From the Windows taskbar, select Start, Programs, Handheld, then Handheld again.
3. The Handheld Meter’s Data Logger screen appears. If a meter is not connected, the input ports will be labeled as
undefined. A sample screen is provided below.
4
Retrieving a File
1. Click the Retrieve File button on the toolbar.
2. Double-click the folder that contains that document you want to open. Click the document name, and then click OK.
3. All documents are in .txt file types, no other file types are valid.
Saving a File
Click the Save File button on the toolbar. You can also save the logged data with a new name by clicking Save File and
typing a new name in the File name field. After saving the file, more statistics or analysis can be done with other
programs.
5
Setting Up the COM Port
1. Click the Com.Port button on the toolbar to enter a COM Port setting.
2. Set up the RS-232 port and related settings such as Baud rate, Data bits, Parity and Stop bits.
3. Click OK to save the setting or Cancel to exit or cancel the setting.
Viewing Statistics
1. Click the Statistics button on the toolbar to see statistics in histogram format.
This example shows the reading for a dual input thermometer. In this example:
On the secondary screen you will see Temperature T1 and Temperature T2 Histogram.
Temperature T1 and T2 range can be set up from 4 divisions to 20 divisions.
Histogram will be automatically changed once re-set Temperature range.
Maximum, Minimum , Mean and Std. Dev (Standard Deviation) are automatically calculated and shown on the right
side of the screen.
6
When you use the TMA-10 Anemometer, the statistic display will show temperature and air flow readings.
Use the Interval control to change the display interval on the screen.
Printing a Graph
1. Click the Print Graph button on the toolbar.
2. To change printers, click Properties, and then select a destination printer.
3. To change paper specifications, enter the settings you want in Graphics Options.
Controlling the Logger Session
Logger Setting
There are two data logging settings settings provided on the TM-SW software, sample data and sample rate.
Sample data: 2,000,4,000, 8,000, 16,000 records.
Sample rate (Second): 1 to 3600. If the rate you enter is out of the range, an Out of Range chart appears showing the
minimum and maximum values for this field.
Click on the up or down arrows to change Sample Data and Sample Rate settings.
7
Recording
Click the Start button to start online recording of measurements .Click the End button to stop recording
YOFFSET and YGAIN
The YGAIN sets the amount of signal between Y axis divisions and the YOFFSET allows you shift the zero axis by the
number on the knob.
For example, if you have a signal varying from 71 to 73 and have zero center on the graph with a YGAIN of 10 ( + 10
divisions), the trace is a limited to a narrow line near the top of the graph. Changing the YGAIN to 5 and YOFFSET to + 5,
the graph Y axis is 25 to 75 and the signal is 2.5 times larger, making it easier to see smaller reading variations
Click on the desired setting to change the YOFFSET and YGAINS range.
Setting the Alarm Limit
1. Click the Alarm SW knob to set the Alarm High and Alarm Low limits.
2. Click the up and down arrows to choose the high and low limit setting.
3. Click the Alarm SW knob again to save your settings.
8
Display Range
Sets the number of records to display. There are 5 ranges you can set: 0.5K (500), 1 K (1,000), 2 K (2,000), 4 K (4,000),
and 8 K (8,000).
Click on the desired setting to change the display range.
Customer Support
For problems with this product or to contact Meterman Test Tools:
In USA
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel: 877-596-2680
Fax: 425-446-6390
In Canada
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, ON L4Z 1X9
Tel: 877-596-2680
Fax: 905-890-6866
European Correspondence Address*
Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
*(Correspondence only. European customers please contact your distributor.)
Logiciel d’interface TM-SW
Table des matières
Introduction .......................................................................................................................................................2
Fonctionnalités TM-SW......................................................................................................................................2
Contenu de l’emballage...................................................................................................................................2
Installation .........................................................................................................................................................2
Configuration matérielle..................................................................................................................................2
Installation du logiciel TM-SW........................................................................................................................2
Utilisation du logiciel TM-SW.................................................................................................. ..........................3
Démarrage du logiciel.....................................................................................................................................3
Récupération d’un fichier................................................................................................................................4
Enregistrement d’un fichier ............................................................................................................................4
Configuration du port COM.............................................................................................................................5
Affichage des statistiques...............................................................................................................................5
Impression d’un graphique.............................................................................................................................6
Contrôle d’une séance de mesure......................................................................................................................6
Réglage de la centrale de mesure............................................................................................... ....................6
Enregistrement................................................................................................................................................7
Décalage YOFFSET et gain YGAIN ................................................................................................. .................7
Configuration du seuil d’alarme......................................................................................................................7
Affichage de la gamme (Display Range).......................................................................................... ...............8
Assistance clientèle........................................................................................................... .................................8
9
Français
Introduction
Le logiciel TM-SW et le câble RS-232 sont destinés aux thermomètres de modèle TMD90 et aux anémomètres TMA10
pour l’acquisition en temps réel des résultats de mesure. Vous pouvez enregistrer ces données sur votre ordinateur pour
créer ultérieurement des analyses, des graphiques ou des rapports.
Fonctionnalités TM-SW
Jusqu’à 16.000 valeurs d’échantillonnage avec horodatage en temps réel.
Intervalle d’échantillonnage programmable de 1 s à 3600 s.
Paramètres d’alarme maximum (haute) et minimum (basse) définis par utilisateur.
Permet une analyse approfondie en téléchargeant les données vers un programme informatique.
Pour faciliter l’analyse des résultats et le contrôle opérationnel, toutes les données sont enregistrées en format texte
(.txt) ; elles peuvent donc être facilement converties pour d’autres applications logicielles.
Contenu de l’emballage
CD-ROM
Câble RS-232 avec connecteur Sub-D
Mode d’emploi
Installation
Configuration matérielle
Systèmes d’exploitation Windows 95/98/NT/2000//ME/XP avec port série COM1 ou COM2.
Installation du logiciel TM-SW
1. Introduisez le cédérom dans le lecteur de cédérom.
2. Cliquez sur le bouton Install Software (Installer le logiciel) sur le menu TM-SW.
3. Suivez les consignes d’installation qui s’affichent.
10
Utilisation du logiciel TM-SW
Démarrage du logiciel
1. Introduisez le connecteur RS-232 dans l’appareil et branchez le câble au port COM sur le PC.
2. Dans la barre de tâches Windows, sélectionnez Start (Démarrer), Programs (Programmes), Handheld, puis de
nouveau Handheld.
3. La centrale de mesure de l’appareil portable (Handheld Meter) apparaît. Si l’appareil n’est pas branché, les ports
d’entrée sont libellés comme étant non définis. Un exemple de cet écran est représenté ci-dessous.
11
Récupération d’un fichier
1. Cliquez sur le bouton Retrieve File (Récupérer le fichier) sur la barre d’outils.
2. Double-cliquez sur le dossier contenant le document à ouvrir. Cliquez sur le nom du document et cliquez sur OK.
3. Tous les documents sont des fichiers de type .txt, aucun autre type de fichier n’est valide.
Enregistrement d’un fichier
Cliquez sur le bouton Save File (Enregistrer le fichier) sur la barre d’outils. Vous pouvez aussi donner aux données
consignées un autre nom en cliquant sur Save File et en tapant le nouveau nom voulu dans la zone File name. Après
avoir enregistré le fichier, d’autres statistiques ou une autre analyse peuvent être effectuées avec d’autres programmes.
12
Configuration du port COM
1. Cliquez sur le bouton Com.Port sur la barre d’outils pour saisir un paramètre de port COM.
2. Configurez le port RS-232 et les paramètres associés : la vitesse de transmission (Baud rate), les bits de données
(Data bits), la parité (Parity) et les bits d’arrêt (Stop bits).
3. Cliquez sur OK pour enregistrer le paramètre ou sur Cancel pour quitter ou annuler le réglage.
Affichage des statistiques
1. Cliquez sur le bouton Statistics (Statistiques) sur la barre d’outils pour afficher les statistiques sous forme
d’histogramme.
Cet exemple montre la valeur relevée pour un thermomètre à double entrée. Dans cet exemple :
L’histogramme des températures T1 et T2 apparaît sur la fenêtre secondaire.
La gamme des températures T1 et T2 peut être définie sur 4 à 20 divisions.
L’histogramme est automatiquement modifié lorsque la gamme des températures est remise à zéro.
13
Valeurs maximum, minimum , moyenne et écart type. L’écart type (Std.Dev) est automatiquement calculé et affiché
(en bas à droite sur l’écran.
Lorsque vous utilisez l’anémomètre TMA-10, l’affichage des statistiques indique la température et les valeurs du débit
d’air relevées.
Utilisez le réglage Interval pour modifier l’intervalle affiché sur l’écran.
Impression d’un graphique
1. Cliquez sur le bouton Print Graph (Imprimer le graphique) sur la barre d’outils.
2. Pour changer d’imprimante, cliquez sur Properties (Propriétés) et sélectionnez l’imprimante voulue.
3. Pour changer les caractéristiques du papier, saisissez les paramètres voulus dans Graphics Options (Options
graphiques).
Contrôle d’une séance de mesure
Réglage de la centrale de mesure
Le logiciel TM-SW fournit deux options d’enregistrement des mesures : données d’échantillonnage avec Sample Data et
vitesse d’échantillonnage avec Sample Rate.
Résultats d’échantillonnage : 2000 ; 4000 ; 8000 ; 16.000 enregistrements.
Taux d’échantillonnage (seconde) : 1 à 3600. Si la vitesse saisie est hors gamme, le graphique Out of Range (Hors
gamme) qui s’affiche indique les valeurs minimum et maximum pour ce champ.
Cliquez sur les flèches haut ou bas pour modifier le nombre de résultats d’échantillonnage et le taux
d’échantillonnage.
14
Enregistrement
Cliquez sur le bouton Start pour lancer l’enregistrement en ligne des mesures. Cliquez sur le bouton End (Fin) pour
arrêter l’enregistrement
Décalage YOFFSET et gain YGAIN
L’option YGAIN règle le gain du signal entre les divisions de l’axe Y et l’option de décalage YOFFSET permet de décaler
l’axe du zéro selon le chiffre défini sur le bouton.
Si le signal varie par exemple de 71 à 73 et si zéro est au centre du graphique avec une valeur YGAIN de 10
( + 10 divisions), la trace se limite à un trait étroit au sommet du graphique. En modifiant le gain YGAIN sur 5 et le
décalage YOFFSET sur + 5, l’axe Y du graphique est compris entre 25 et 75 et le signal est 2,5 fois plus grand, facilitant
ainsi l’identification des variations de lecture plus réduites
Cliquez sur le paramètre souhaité pour modifier la gamme YOFFSET et YGAINS.
Configuration du seuil d’alarme
1. Cliquez sur le bouton Alarm SW pour régler les seuils d’alarme basse Alarm Low et haute, Alarm High.
2. Cliquez sur les flèches haut et bas pour choisir le réglage du seuil bas Low Limit et haut High Limit.
3. Cliquez de nouveau sur le bouton Alarm SW pour enregistrer vos paramètres.
15
Affichage de la gamme (Display Range)
Règle le nombre d’enregistrements à afficher. Vous pouvez définir 5 gammes : 0,5K (500) : 1 K (1000) ; 2 K (2000) ; 4 K
(4000) ; et 8 K (8000).
Cliquez sur le paramètre souhaité pour modifier la gamme à afficher.
Assistance clientèle
Pour tout problème concernant ce produit ou pour contacter Meterman Test Tools :
Aux Etats-Unis
Meterman Test Tools
1420 75
th
Street SW
Everett, WA 98203
Tél. : 877-596-2680
Fax : 425-446-6390
Au Canada
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, Ontario L4Z 1X9
Tél. : 877-596-2680
Fax : 905-890-6866
Adresse postale européenne*
Meterman Test Tools Europe
P.O. Box 1186
5602 B.D. Eindhoven
Pays-Bas
*
(Réservée à la correspondance. Nos clients européens doivent contacter leur distributeur).
16
TM-SW-Schnittstellensoftware
Inhalt
Einleitung ...........................................................................................................................................................2
TM-SW-Merkmale................................................................................................................. .............................2
Paketinhalt ......................................................................................................................................................2
Installation .........................................................................................................................................................2
Soft- und Hardwareanforderungen.................................................................................................................2
Installation der TM-SW-Software ...................................................................................................................2
Verwendung der TM-SW-Software.................................................................................................. ..................3
Starten der Software........................................................................................................... ............................3
Abrufen einer Datei .........................................................................................................................................4
Speichern einer Datei......................................................................................................................................4
Einrichten des COM-Anschlusses................................................................................................. ..................5
Anzeigen von Statistik.....................................................................................................................................5
Drucken einer Grafik.......................................................................................................................................6
Steuerung der Aufzeichnungssitzung................................................................................................................6
Datenlogger-Einstellung (Logger Setting)....................................................................................... ...............6
Aufzeichnung (Recording)..............................................................................................................................7
Y-OFFSET und Y-GAIN....................................................................................................................................7
Einstellen der Alarm-Grenzwerte ....................................................................................................................7
Anzeigebereich (Display Range).....................................................................................................................8
Kundendienst .....................................................................................................................................................8
17
Deutsch
Einleitung
Die TM-SW-Software und das RS-232-Kabel wird mit Modellen des TMD90 Thermometers und des TMA10 Anemometers
für Echtzeit-Datenerfassung von Messergebnissen verwendet. Die Daten können für weitere Analysen, Datenberichte und
grafische Datendarstellungen auf einem Computer gespeichert werden.
TM-SW-Merkmale
Bis zu 16'000 Messwerte mit Echtzeit-Datum-Zeitstempel.
Programmierbares Intervall von 1 bis 3'600 Sekunden.
Benutzerdefinierte Maximal (High)- und Minimal (Low)-Alarmeinstellungen.
Ermöglicht weitere Analysen durch Herunterladen von Daten auf einen Computer.
Zur Unterstützung von Datenanalysen und Prozesslenkung werden alle Daten im Textformat (.txt) gespeichert und
können daher einfach zur Verwendung in anderen Softwareanwendungen übertragen werden.
Paketinhalt
CD-ROM
RS-232-Kabel mit Sub-D-Stecker
Bedienungshandbuch
Installation
Soft- und Hardwareanforderungen
Betriebssystem Windows 95/98/NT/2000//ME/XP mit einem seriellen COM1 oder COM2-Anschluss.
Installation der TM-SW-Software
1. Die CD in das CD-ROM-Laufwerk einlegen.
2. Im TM-SW-Menü auf die Schaltfläche Install Software (Software installieren) klicken.
3. Den auf dem Bildschirm eingeblendeten Installationsanweisungen folgen.
18
Verwendung der TM-SW-Software
Starten der Software
1. Den RS-232-Anschluss in das Messgerät einführen und das Kabel am COM-Anschluss des PCs anschließen.
2. Auf der Windows-Taskleiste Start, Programs, Handheld und dann nochmals Handheld auswählen.
3. Der Datenlogger-Bildschirm des Handheld-Messgeräts wird eingeblendet. Wenn kein Messgerät angeschlossen ist,
sind die Eingangsanschlüsse als „Undefined“ (nicht definiert) bezeichnet. Ein Beispielbildschirm ist unten abgebildet.
19
Abrufen einer Datei
1. Auf der Symbolleiste auf die Schaltfläche Retrieve File (Datei abrufen) klicken.
2. Auf den Ordner doppelklicken, der das zu öffnende Dokument enthält. Auf den Dokumentnamen klicken und dann auf
OK klicken.
3. Alle Dokumente weisen den Dateityp .txt auf, keine anderen Dateitypen sind gültig.
Speichern einer Datei
Auf der Symbolleiste auf die Schaltfläche Save File (Datei speichern) klicken. Aufgezeichnete Daten können auch unter
einem neuen Namen gespeichert werden. Dazu auf die Schaltfläche Save File (Datei speichern) klicken und einen neuen
Namen in das Dateinamenfeld eingeben. Nach der Speicherung der Datei können mit anderen Programmen weitere
statistische Auswertungen oder Analysen durchgeführt werden.
20
Einrichten des COM-Anschlusses
1. Auf der Symbolleiste auf die Schaltfläche Com.Port (COM-Anschluss) klicken, um die Einstellungen des COM-Anschlusses einzurichten.
2. Den RS-232-Anschluss und zugehörige Einstellungen einrichten: zum Beispiel Baud Rate (Baudrate), Data Bits (Datenbits), Parity
(Parität) und Stop Bits (Stoppbits).
3. Auf OK klicken, um die Einstellung zu speichern, oder auf Cancel (Abbrechen) klicken, um die Einstellung abzubrechen bzw. zu beenden.
Anzeigen von Statistik
1. Auf der Symbolleiste auf die Schaltfläche Statistics (Statistik) klicken, um Statistikdaten im Histogrammformat anzuzeigen.
Dieses Beispiel zeigt die Messwerte eines Dual-Input-Thermometers. In diesem Beispiel:
Zeigt der sekundäre Bildschirm Temperatur T1 und Temperatur T2 Histogramm an.
Die Temperaturbereiche T1 und T2 können von 4 Teilungen bis 20 Teilungen eingerichtet werden.
Histogramm wird automatisch verändert, sobald der Temperaturbereich neu gesetzt wird.
21
Maximum (Höchstwert), Minimum (Niedrigstwert), Mean (Mittelwert) und Std. Dev (Standardabweichung) werden
automatisch berechnet und auf der linken Seite des Bildschirms angezeigt.
Wenn das TMA10 Anemometer verwendet wird, zeigt die Statistikanzeige Temperatur- und Luftflussmesswerte an.
Zum Ändern des Anzeigeintervalls auf dem Bildschirm die Intervallsteuerung verwenden.
Drucken einer Grafik
1. Auf der Symbolleiste auf die Schaltfläche Print Graph (Grafik drucken) klicken.
2. Um den Drucker zu wechseln, auf Properties (Eigenschaften) klicken und dann einen Zieldrucker auswählen.
3. Um die Papierspezifikationen zu ändern, die gewünschten Einstellungen unterGraphics Options“ (Grafikoptionen) eingeben.
Steuerung der Aufzeichnungssitzung
Datenlogger-Einstellung (Logger Setting)
Die TM-SW-Software unterstützt zwei Datenlogger-Einstellungen: „Sample Data“ und „Sample Rate“.
Sample Data: 2000, 4000, 8000 und 16000 Datensätze.
Sample Rate: 1 bis 3600 Sekunden. Wenn die eingegebene Rate außerhalb des gültigen Bereichs liegt, wird eine „Out of
Range“-Meldung mit den Minimum- und Maximumwerten für dieses Feld eingeblendet.
Zum Ändern der Einstellungen „Sample Data“ und „Sample Rate“ auf den Aufwärts- bzw. Abwärtspfeil klicken.
22
Aufzeichnung (Recording)
Auf die Schaltfläche Start (Starten) klicken, um die Online-Aufzeichnung von Messungen zu starten. Auf die
Schaltfläche End (Beenden) klicken, um die Aufzeichnung zu stoppen.
Y-OFFSET und Y-GAIN
Y-GAIN (Y-Verstärkung) legt die Signalmenge zwischen Y-Achse-Teilungen fest. Y-OFFSET (Y-Offset) ermöglicht das
Verschieben der Nullachse entsprechend der Zahl auf dem Knopf.
Schwankt beispielsweise ein Signal zwischen 71 und 73, und die Nullachse auf dem Diagramm ist auf einen Y-GAIN-Wert
von 10 ( + 10 Teilungen) gesetzt, dann ist die Kurve auf einen schmalen Bereich oben im Diagramm beschränkt. Wenn Y-
GAIN auf 5 und Y-OFFSET auf + 5 verändert werden, liegt die Y-Achse zwischen 25 und 75, und das Signal ist 2,5 Mal
größer, wodurch kleine Messschwankungen einfacher zu sehen sind.
Auf die gewünschte Einstellung klicken, um den Y-OFFSET- und Y-GAIN-Bereich zu ändern.
Einstellen der Alarm-Grenzwerte
1. Auf den Knopf „Alarm SW“ klicken, um die Grenzwerte „Alarm High“ und „Alarm Low“ einzustellen.
2. Auf den Aufwärts- bzw. Abwärtspfeil um den Höchstwert und den Niedrigstwert festzulegen.
3. Nochmals auf den Knopf „Alarm SW“ klicken, um die Einstellungen zu speichern.
23
Anzeigebereich (Display Range)
Legt die Anzahl der anzuzeigenden Datensätze fest. Zur Auswahl stehen 5 Bereiche: 0,5 K (500), 1 K (1000), 2 K (2000),
4 K (4000) und 8 K (8000).
Auf die gewünschte Einstellung klicken, um den Anzeigebereich zu ändern.
Kundendienst
Bei Problemen mit diesem Produkt Meterman Test Tools benachrichtigen:
In den USA:
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel.: 877-596-2680
Fax: 425-446-6390
In Kanada:
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, ON L4Z 1X9
Tel.: 877-596-2680
Fax: 905-890-6866
Korrespondenzanschrift für Europa*
Meterman Test Tools Europe
P. O. Box 1186
5602 BD Eindhoven
Niederlande
*(Nur Korrespondenz. Kunden in Europa wenden sich an den zuständigen Distributor.)
24
Software di interfaccia TM-SW
Indice
Introduzione.......................................................................................................................................................2
Caratteristiche del software TM-SW............................................................................................. .....................2
Contenuto della confezione.............................................................................................................................2
Installazione .......................................................................................................................................................2
Requisiti hardware..........................................................................................................................................2
Installazione del software TM-SW..................................................................................................................2
Uso del software TM-SW...................................................................................................................................3
Avvio del software...........................................................................................................................................3
Reperimento di un file.....................................................................................................................................4
Salvataggio di un file.......................................................................................................................................4
Impostazione della porta COM........................................................................................................................5
Visualizzazione dei dati statistici............................................................................................ .........................5
Stampa di un grafico.......................................................................................................................................6
Controllo delle sessioni di registrazione............................................................................................................6
Impostazione del registro...............................................................................................................................6
Registrazione ..................................................................................................................................................7
Parametri YOFFSET e YGAINS........................................................................................................................7
Impostazione del limite di allarme..................................................................................................................7
Parametro Display Range (Portata del display)..............................................................................................8
Supporto clienti..................................................................................................................................................8
25
Italiano
Introduzione
Il software TM-SW e il cavo RS-232 vengono usati con i termometri modello TMD90 e gli anemometri modello TMA10
per l’acquisizione in tempo reale dei dati e dei risultati delle misure, che possono in seguito essere memorizzati in un
computer per ulteriori analisi, relazioni e grafici.
Caratteristiche del software TM-SW
Fino a 16.000 letture di campioni con marcatura temporale in tempo reale.
Intervallo di campionamento programmabile da 1 a 3.600 secondi.
Limiti di allarme minimo e massimo definiti dall’utente.
Possibilità di analisi ulteriori mediante lo scaricamento di dati in un programma software.
Per agevolare l’analisi dei dati e il controllo dei processi, tutti i dati sono salvati in formato di testo (.txt) e possono
essere facilmente elaborati per l’uso con altre applicazioni software.
Contenuto della confezione
CD-ROM
Cavo RS-232 con connettore Sub-D
Manuale d’uso
Installazione
Requisiti hardware
Sistema operativo Windows 95/98/NT/2000//ME/XP con porta seriale COM1 o COM2.
Installazione del software TM-SW
1. Inserire il CD nell’apposita unità.
2. Fare clic sul pulsante Install Software (Installa il software) nel menu TM-SW.
3. Seguire le istruzioni di installazione sullo schermo.
26
Uso del software TM-SW
Avvio del software
1. Inserire il connettore RS-232 nello strumento e collegare il cavo alla porta COM del PC.
2. Nella barra delle applicazioni di Windows, selezionare Start (Avvio), Programs (Programmi), Handheld (Palmare) e di
nuovo Handheld.
3. Appare lo schermo Data Logger (Registro dati) dello strumento palmare. Se non è stato collegato alcun multimetro, le
porte di ingresso risultano “undefined” (indefinite). Di seguito è illustrato un esempio di questo schermo.
27
Reperimento di un file
1. Fare clic sul pulsante Retrieve File (Reperisci file) sulla barra degli strumenti.
2. Fare doppio clic sulla cartella che contiene il documento da aprire. Fare clic sul nome del documento e quindi su OK.
3. Tutti i documenti sono nel formato di testo .txt; non sono ammessi altri tipi di file.
Salvataggio di un file
Fare clic sul pulsante Save File (Salva file) sulla barra degli strumenti. È anche possibile memorizzare con un nome
diverso i dati registrati: fare clic su Save File e digitare il nuovo nome nel campo File name (Nome file). Dopo il
salvataggio del file, si possono effettuare ulteriori elaborazioni statistiche e analisi con altri programmi.
28
Impostazione della porta COM
1. Fare clic sul pulsante Com.Port (Porta COM) sulla barra degli strumenti per accedere alle impostazioni della porta COM.
2. Impostare la porta RS-232 e i relativi parametri, quali Baud rate (Velocità di trasmissione), Data bits (Bit di dati),
Parity (Parità) e Stop bits (Bit di stop).
3. Fare clic su OK per memorizzare l’impostazione o su Cancel (Annulla) per uscire senza salvare le modifiche.
Visualizzazione dei dati statistici
1. Fare clic sul pulsante Statistics (Statistiche) sulla barra degli strumenti per visualizzare un istogramma dei dati statistici.
Questo esempio illustra i valori rilevati da un termometro a due ingressi:
lo schermo secondario presenta gli istogrammi di temperatura T1 e T2;
le gamme di temperatura T1 e T2 possono essere definite fra 4 e 20 divisioni;
l’istogramma si aggiorna automaticamente una volta completata la ridefinizione della gamma di temperatura;
i valori massimo, minimo, medio e la deviazione standard sono calcolati automaticamente e visualizzati sul lato destro
dello schermo nei campi Maximum, Minimum, Mean e Std.Dev;
29
quando si usa l’anemometro TMA-10, la visualizzazione statistica mostra i valori relativi alla temperatura e al flusso d’aria;
gli intervalli visualizzati sullo schermo possono essere modificati con i comandi Intervals.
Stampa di un grafico
1. Fare clic sul pulsante Print Graph (Stampa grafico) sulla barra degli strumenti.
2. Per cambiare la stampante, fare clic su Properties (Proprietà) e selezionare la stampante di destinazione.
3. Per cambiare le proprietà della carta, definire i parametri nella sezione Graphics Options (Opzioni grafica).
Controllo delle sessioni di registrazione
Impostazione del registro
Il software TM-SW offre due impostazioni di registrazione dei dati: dati di campionamento e frequenza di campionamento.
L’impostazione Sample data (Dati di campionamento) permette di registrare 2.000, 4.000, 8.000 o 16.000 record.
L’impostazione Sample rate (Sec.) [Frequenza di campionamento (secondi)] accetta valori da 1 a 3600. Se la frequenza
immessa è fuori gamma, il display visualizza un grafico “Out of Range” che indica i valori minimo e massimo
dell’impostazione.
Fare clic sulla freccia in su o in giù per cambiare i valori dei campi Sample Data e Sample Rate.
30
Registrazione
Fare clic sul pulsante Start (Avvio) per iniziare la registrazione online delle misure; fare clic su End (Fine) per terminarla.
Parametri YOFFSET e YGAINS
Il parametro YGAINS definisce il guadagno del segnale tra le divisioni dell’asse Y; il parametro YOFFSET permette di
spostare lo zero dell’asse in base al numero indicato dal selettore.
Ad esempio, se si ha un segnale che varia da 71 a 73 e l’origine del grafico è a zero con un guadagno YGAINS pari a 10
(+10 divisioni), il tracciato mostra una linea pressoché retta lungo la parte superiore dello schermo. Impostando il
guadagno YGAINS su 5 e il parametro YOFFSET su +5, l’asse Y del grafico visualizza valori tra 25 e 75 e il segnale risulta
2,5 volte più ampio, rendendo maggiormente visibili le variazioni minori.
Modificare i parametri YOFFSET e YGAINS facendo clic sull’impostazione desiderata.
Impostazione del limite di allarme
1. Fare clic sul selettore Alarm SW per impostare i limiti di allarme superiore e inferiore.
2. Fare clic sulle frecce in su e in giù per scegliere i valori massimo e minimo desiderati.
3. Fare clic di nuovo sul selettore Alarm SW per salvare le impostazioni.
31
Parametro Display Range (Portata del display)
Determina il numero di record visualizzabili sul display. Le opzioni disponibili sono 5: 0,5k (500), 1k (1.000), 2k (2.000),
4k (4.000) e 8k (8.000).
Modificare la portata del display facendo clic sull’impostazione desiderata.
Supporto clienti
In caso di problemi o per qualsiasi altro quesito riguardante il prodotto, rivolgersi alla Meterman Test Tools agli indirizzi e
ai numeri seguenti:
U.S.A.
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel: 877 596 2680
Fax: +1 425 446 6390
Canada
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, ON L4Z 1X9
Tel: 877 596 2680
Fax: +1 905 890 6866
Recapito postale europeo*
Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
Paesi Bassi
*(Solo per corrispondenza. Si pregano i clienti europei di rivolgersi al proprio rivenditore.)
32
Software para interfaz TM-SW
Contenido
Introducción.................................................................................................................................................................2
Funciones del TM-SW..................................................................................................................................................2
Contenido del módulo...............................................................................................................................................2
Instalación....................................................................................................................................................................2
Requisitos de hardware............................................................................................................................................2
Instalación del software TM-SW...............................................................................................................................2
Empleo del software TM-SW.......................................................................................................................................3
Inicio del software.....................................................................................................................................................3
Recuperación de un archivo .....................................................................................................................................4
Procedimiento para guardar un archivo.......................................................................................... .........................4
Configuración del puerto COM .................................................................................................................................5
Visualización de estadísticas ....................................................................................................................................5
Impresión de un gráfico............................................................................................................................................6
Control de la sesión del registrador.............................................................................................................................6
Configuración del registrador ...................................................................................................................................6
Registro ....................................................................................................................................................................7
DESPLAZAMIENTO Y y GANANCIA Y.......................................................................................................................7
Configuración del límite de alarma...........................................................................................................................7
Rango de exhibición .................................................................................................................................................8
Servicio de asistencia a clientes ..................................................................................................................................8
33
Español
Introducción
El software TM-SW y el cable RS-232 se utilizan con los modelos TMD90 termómetro y TMA10 anemómetro para la
adquisición en tiempo real de los datos correspondientes a los resultados de sus mediciones. Usted los puede almacenar
en su computadora para seguir analizándolos o realizar informes de datos o graficación.
Funciones del TM-SW
Hasta 16.000 lecturas de muestras con estampado de fecha y hora en tiempo real.
Intervalo de muestras programable entre 1 y 3.600 segundos.
Configuraciones de alarma máxima (alta) y mínima (baja) definibles por el usuario.
Permite análisis adicionales descargando datos a un programa de computación.
Para asistir con el análisis de los datos y el control del proceso, toda la información es guardada en formato de texto
(.txt) y puede ser fácilmente transformada para su empleo por otras aplicaciones de software.
Contenido del módulo
CD-ROM
Cable RS-232 con conector Sub-D
Manual del usuario
Instalación
Requisitos de hardware
Sistemas operativos Windows 95/98/NT/2000//ME/XP con un puerto serie disponible COM1 o COM2.
Instalación del software TM-SW
1. Inserte el CD en su unidad de disco CD-ROM.
2. Haga clic sobre el botón Install Software (Instalar software) del menú TM-SW.
3. Siga las instrucciones de instalación que aparecen en la pantalla.
34
Empleo del software TM-SW
Inicio del software
1. Inserte el conector RS-232 en el multímetro y conecte el cable al puerto COM de su PC.
2. Desde la barra de tareas de Windows, seleccione Start (Inicio), Programs (Programas), Handheld, luego nuevamente
Handheld.
3. Aparecerá la pantalla de registro de datos del multímetro portátil. Si no hay un multímetro conectado, los puertos de
entrada estarán rotulados como no definidos. A continuación, se provee una pantalla de muestra.
35
Recuperación de un archivo
1. Haga clic sobre el botón Retrieve File (Recuperar archivo) de la barra de herramientas.
2. Haga doble clic sobre la carpeta que contiene el documento que desea abrir. Haga clic sobre el nombre del
documento, y luego haga clic sobre OK (Aceptar).
3. Todos los documentos están en archivos de tipo .txt; ningún otro tipo de archivo es válido.
Procedimiento para guardar un archivo
Haga clic sobre el botón Save File (Guardar archivo) de la barra de herramientas. Usted puede también guardar la
información registrada bajo un nuevo nombre haciendo clic sobre Save File (Guardar archivo) y escribiendo un nuevo
nombre en el campo Nombre de archivo. Luego de guardar el archivo, pueden realizarse más estadísticas o análisis con
otros programas.
36
Configuración del puerto COM
1. Para ingresar una configuración del puerto COM, haga clic sobre el botón Com.Port (Puerto Com) de la barra de
herramientas.
2. Configure el puerto RS-232 y configuraciones asociadas tales como velocidad en baudios, bits de datos y bits de
paridad y parada.
3. Haga clic sobre OK (Aceptar) para guardar la configuración o Cancel (CANCELAR) para salir o para cancelar la
configuración.
Visualización de estadísticas
1. Haga clic sobre el botón Statistics (Estadísticas) de la barra de herramientas para ver estadísticas en formato de
histograma.
Este ejemplo muestra la lectura para un termómetro de doble entrada. En este ejemplo:
En la pantalla secundaria usted verá el Histograma de Temperatura T1 y Temperatura T2.
El rango de las temperaturas T1 y T2 puede ser establecido desde 4 divisiones hasta 20 divisiones.
37
El histograma será modificado automáticamente una vez que se modifique el rango de temperaturas.
Máximo, Mínimo , Medio y Estándar. La Dev (Desviación estándar) es calculada automáticamente y exhibida en el
costado derecho de la pantalla.
Cuando se utiliza el anemómetro TMA-10, la exhibición de estadísticas mostrará lecturas de temperatura y flujo
de aire.
Utilice el control de intervalo para cambiar el intervalo exhibido en la pantalla.
Impresión de un gráfico
1. Haga clic sobre el botón Print Graph (Imprimir gráfico) de la barra de herramientas.
2. Para cambiar impresoras, haga clic sobre Properties (Propiedades) y luego seleccione una impresora de destino.
3. Para cambiar especificaciones del papel, ingrese las configuraciones deseadas en Opciones gráficas.
Control de la sesión del registrador
Configuración del registrador
Existen dos configuraciones de registro de datos provistas en el software TM-SW: los datos de muestra y la frecuencia de
muestreo.
Datos de muestra: 2.000, 4.000, 8.000 y 16.000 registros.
Frecuencia de muestreo (segunda): 1 a 3600. Si la frecuencia que se ingresa está fuera de rango, aparecerá un gráfico de
fuera de rango que muestra los valores mínimo y máximo para este campo.
Haga clic sobre los botones de flecha arriba o flecha abajo para cambiar las configuraciones de muestras de datos y
de frecuencia de muestreo.
38
Registro
Haga clic sobre el botón Start (Inicio) para iniciar el registro en línea de las mediciones. Haga clic sobre el botón End
(Finalizar) para detener el registro
DESPLAZAMIENTO Y y GANANCIA Y
La YGAIN (GANANCIA Y) establece la cantidad de señal entre divisiones del eje Y y el YOFFSET (DESPLAZAMIENTO Y) le
permite desplazar el eje cero según el número presente en la perilla.
Por ejemplo, si usted tiene una señal que varía de 71 a 73 y tiene centro cero en el gráfico con una YGAIN (GANANCIA Y)
de 10 ( + 10 divisiones), la traza está limitada a una línea angosta cerca de la parte superior del gráfico. Modificando la
YGAIN (GANANCIA Y) a 5 y el YOFFSET (DESPLAZAMIENTO Y) a + 5, el eje Y del gráfico es 25 a 75 y la señal es 2,5
veces mayor, haciendo más sencillo visualizar variaciones más pequeñas de lectura
Haga clic sobre la configuración deseada para cambiar el rango de YOFFSET (DESPLAZAMIENTO Y) y YGAIN
(GANANCIA Y).
Configuración del límite de alarma
1. Haga clic sobre la perilla de alarma SW para configurar los límites de alarma alta y alarma baja.
2. Haga clic sobre los botones de flecha arriba y flecha abajo para seleccionar la configuración de los límites alto y bajo.
3. Haga clic nuevamente sobre la perilla de alarma SW para guardar sus configuraciones.
39
Rango de exhibición
Establece el número de registros a ser exhibidos. Hay 5 rangos que se pueden establecer: 0,5 K (500), 1 K (1.000), 2 K
(2.000), 4 K (4.000) y 8 K (8.000).
Haga clic sobre la configuración deseada para cambiar el rango de exhibición.
Servicio de asistencia a clientes
Para consultar por problemas con este producto o para comunicarse con Meterman Test Tools:
En Estados Unidos
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel.: 877-596-2680
Fax: 425-446-6390
En Cana
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, Ontario L4Z 1X9
Tel.: 877-596-2680
Fax: 905-890-6866
Dirección para envío de correspondencia en
Europa*
Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
Holanda
*
(Correspondencia solamente. Los clientes europeos deben ponerse en contacto con su distribuidor).
40
TM-SWTM-SW
RS232 Software
and Cable
For use with Meterman Model TMD90,
Digital Thermometer and
Model TMA10, Anemometer
User Manual
Mode d'emploi
• Bedienungshandbuch
• Manuale d'Uso
Manual de uso
U.S. Service Center
Meterman Test Tools
1420 75th Street SW
Everett, WA 98203
Tel: 877-596-2680
Fax: 425-446-4882
Canadian Service Center
Meterman Test Tools
400 Britannia Rd. E. Unit #1
Mississauga, ON L4Z 1X9
Tel: 877-596-2680
Fax: 425-446-4882
European Correspondence Address*
Meterman Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
*Correspondence only - no repair or replacement available from this
address. European customers please contact your distributor.
Visit www.metermantesttools.com for
• Catalog
• Application notes
• Product specifications
• Product manuals
PN 2106913
January 2004
© Wavetek Meterman Test Tools.
All rights reserved. Printed in Taiwan.
Please Recycle
®
®
®
®

Transcripción de documentos

TM-SW TM-SW ® ® ® ® U.S. Service Center RS232 Software and Cable Meterman Test Tools 1420 75th Street SW Everett, WA 98203 Tel: 877-596-2680 Fax: 425-446-4882 For use with Meterman Model TMD90, Digital Thermometer and Model TMA10, Anemometer Canadian Service Center Meterman Test Tools 400 Britannia Rd. E. Unit #1 Mississauga, ON L4Z 1X9 Tel: 877-596-2680 Fax: 425-446-4882 User Manual European Correspondence Address* Meterman Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands *Correspondence only - no repair or replacement available from this address. European customers please contact your distributor. Visit www.metermantesttools.com for • Catalog • Application notes • Product specifications • Product manuals PN 2106913 January 2004 © Wavetek Meterman Test Tools. All rights reserved. Printed in Taiwan. Please Recycle • Mode d'emploi • Bedienungshandbuch • Manuale d'Uso • Manual de uso TM-SW Interface Software Introduction .......................................................................................................................................................2 TM-SW Features ................................................................................................................................................2 Package Contents ...........................................................................................................................................2 Installation .........................................................................................................................................................2 Hardware Requirements .................................................................................................................................2 Installing TM-SW Software.............................................................................................................................2 Using the TM-SW Software ...............................................................................................................................3 Starting the Software......................................................................................................................................3 Retrieving a File ..............................................................................................................................................4 Saving a File....................................................................................................................................................4 Setting Up the COM Port ................................................................................................................................5 Viewing Statistics............................................................................................................................................5 Printing a Graph..............................................................................................................................................6 Controlling the Logger Session .........................................................................................................................6 Logger Setting ................................................................................................................................................6 Recording........................................................................................................................................................7 YOFFSET and YGAIN.......................................................................................................................................7 Setting the Alarm Limit...................................................................................................................................7 Display Range .................................................................................................................................................8 Customer Support..............................................................................................................................................8 1 English Contents Introduction The TM-SW software and RS-232 cable is used with the TMD90 Thermometer and TMA10 Anemometer for real time data acquisition of your measurement results. You can store the data on your computer for further analysis, data reporting, or charting. TM-SW Features • • • • • Up to 16,000 sample readings with real-time date and time-stamp. Programmable sample interval from 1 to 3,600 seconds. User-defined maximum (High) and minimum alarm (Low) settings. Allow further analysis by downloading data to a computer program. To assist with data analysis and process control, all data is saved in text format (.txt) and can be easily transformed for use by other software applications. Package Contents • • • CD-ROM RS-232 cable with Sub-D connector User-Manual Installation Hardware Requirements Windows 95/98/NT/2000//ME/XP operating systems with a COM1 or COM2 serial port. Installing TM-SW Software 1. Insert the CD into your CD-ROM drive. 2. Click the Install Software button on the TM-SW menu. 3. Follow the installation instructions that appear on the screen. 2 Using the TM-SW Software Starting the Software 1. Insert the RS-232 connector in the meter and connect the cable to the COM port on your PC. 2. From the Windows taskbar, select Start, Programs, Handheld, then Handheld again. 3. The Handheld Meter’s Data Logger screen appears. If a meter is not connected, the input ports will be labeled as undefined. A sample screen is provided below. 3 Retrieving a File 1. Click the Retrieve File button on the toolbar. 2. Double-click the folder that contains that document you want to open. Click the document name, and then click OK. 3. All documents are in .txt file types, no other file types are valid. Saving a File Click the Save File button on the toolbar. You can also save the logged data with a new name by clicking Save File and typing a new name in the File name field. After saving the file, more statistics or analysis can be done with other programs. 4 Setting Up the COM Port 1. Click the Com.Port button on the toolbar to enter a COM Port setting. 2. Set up the RS-232 port and related settings such as Baud rate, Data bits, Parity and Stop bits. 3. Click OK to save the setting or Cancel to exit or cancel the setting. Viewing Statistics 1. Click the Statistics button on the toolbar to see statistics in histogram format. This example shows the reading for a dual input thermometer. In this example: • On the secondary screen you will see Temperature T1 and Temperature T2 Histogram. • Temperature T1 and T2 range can be set up from 4 divisions to 20 divisions. • Histogram will be automatically changed once re-set Temperature range. • Maximum, Minimum , Mean and Std. Dev (Standard Deviation) are automatically calculated and shown on the right side of the screen. 5 • • When you use the TMA-10 Anemometer, the statistic display will show temperature and air flow readings. Use the Interval control to change the display interval on the screen. Printing a Graph 1. Click the Print Graph button on the toolbar. 2. To change printers, click Properties, and then select a destination printer. 3. To change paper specifications, enter the settings you want in Graphics Options. Controlling the Logger Session Logger Setting There are two data logging settings settings provided on the TM-SW software, sample data and sample rate. Sample data: 2,000,4,000, 8,000, 16,000 records. Sample rate (Second): 1 to 3600. If the rate you enter is out of the range, an Out of Range chart appears showing the minimum and maximum values for this field. • Click on the up or down arrows to change Sample Data and Sample Rate settings. 6 Recording • Click the Start button to start online recording of measurements .Click the End button to stop recording YOFFSET and YGAIN The YGAIN sets the amount of signal between Y axis divisions and the YOFFSET allows you shift the zero axis by the number on the knob. For example, if you have a signal varying from 71 to 73 and have zero center on the graph with a YGAIN of 10 ( + 10 divisions), the trace is a limited to a narrow line near the top of the graph. Changing the YGAIN to 5 and YOFFSET to + 5, the graph Y axis is 25 to 75 and the signal is 2.5 times larger, making it easier to see smaller reading variations • Click on the desired setting to change the YOFFSET and YGAINS range. Setting the Alarm Limit 1. Click the Alarm SW knob to set the Alarm High and Alarm Low limits. 2. Click the up and down arrows to choose the high and low limit setting. 3. Click the Alarm SW knob again to save your settings. 7 Display Range Sets the number of records to display. There are 5 ranges you can set: 0.5K (500), 1 K (1,000), 2 K (2,000), 4 K (4,000), and 8 K (8,000). • Click on the desired setting to change the display range. Customer Support For problems with this product or to contact Meterman Test Tools: In USA In Canada Meterman Test Tools Meterman Test Tools 1420 75th Street SW 400 Britannia Rd. E. Unit #1 Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-596-2680 Tel: 877-596-2680 Fax: 425-446-6390 Fax: 905-890-6866 European Correspondence Address* Meterman Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands *(Correspondence only. European customers please contact your distributor.) 8 Logiciel d’interface TM-SW Introduction .......................................................................................................................................................2 Fonctionnalités TM-SW.......................................................................................................... ............................2 Contenu de l’emballage...................................................................................................................................2 Installation .........................................................................................................................................................2 Configuration matérielle..................................................................................................................................2 Installation du logiciel TM-SW................................................................................................. .......................2 Utilisation du logiciel TM-SW .................................................................................................. ..........................3 Démarrage du logiciel.......................................................................................................... ...........................3 Récupération d’un fichier...................................................................................................... ..........................4 Enregistrement d’un fichier .................................................................................................... ........................4 Configuration du port COM.............................................................................................................................5 Affichage des statistiques...............................................................................................................................5 Impression d’un graphique.............................................................................................................................6 Contrôle d’une séance de mesure......................................................................................................................6 Réglage de la centrale de mesure............................................................................................... ....................6 Enregistrement................................................................................................................................................7 Décalage YOFFSET et gain YGAIN ................................................................................................. .................7 Configuration du seuil d’alarme......................................................................................................................7 Affichage de la gamme (Display Range).......................................................................................... ...............8 Assistance clientèle........................................................................................................... .................................8 9 Français Table des matières Introduction Le logiciel TM-SW et le câble RS-232 sont destinés aux thermomètres de modèle TMD90 et aux anémomètres TMA10 pour l’acquisition en temps réel des résultats de mesure. Vous pouvez enregistrer ces données sur votre ordinateur pour créer ultérieurement des analyses, des graphiques ou des rapports. Fonctionnalités TM-SW • Jusqu’à 16.000 valeurs d’échantillonnage avec horodatage en temps réel. • Intervalle d’échantillonnage programmable de 1 s à 3600 s. • Paramètres d’alarme maximum (haute) et minimum (basse) définis par utilisateur. • Permet une analyse approfondie en téléchargeant les données vers un programme informatique. • Pour faciliter l’analyse des résultats et le contrôle opérationnel, toutes les données sont enregistrées en format texte (.txt) ; elles peuvent donc être facilement converties pour d’autres applications logicielles. Contenu de l’emballage • • • CD-ROM Câble RS-232 avec connecteur Sub-D Mode d’emploi Installation Configuration matérielle Systèmes d’exploitation Windows 95/98/NT/2000//ME/XP avec port série COM1 ou COM2. Installation du logiciel TM-SW 1. Introduisez le cédérom dans le lecteur de cédérom. 2. Cliquez sur le bouton Install Software (Installer le logiciel) sur le menu TM-SW. 3. Suivez les consignes d’installation qui s’affichent. 10 Utilisation du logiciel TM-SW Démarrage du logiciel 1. Introduisez le connecteur RS-232 dans l’appareil et branchez le câble au port COM sur le PC. 2. Dans la barre de tâches Windows, sélectionnez Start (Démarrer), Programs (Programmes), Handheld, puis de nouveau Handheld. 3. La centrale de mesure de l’appareil portable (Handheld Meter) apparaît. Si l’appareil n’est pas branché, les ports d’entrée sont libellés comme étant non définis. Un exemple de cet écran est représenté ci-dessous. 11 Récupération d’un fichier 1. Cliquez sur le bouton Retrieve File (Récupérer le fichier) sur la barre d’outils. 2. Double-cliquez sur le dossier contenant le document à ouvrir. Cliquez sur le nom du document et cliquez sur OK. 3. Tous les documents sont des fichiers de type .txt, aucun autre type de fichier n’est valide. Enregistrement d’un fichier Cliquez sur le bouton Save File (Enregistrer le fichier) sur la barre d’outils. Vous pouvez aussi donner aux données consignées un autre nom en cliquant sur Save File et en tapant le nouveau nom voulu dans la zone File name. Après avoir enregistré le fichier, d’autres statistiques ou une autre analyse peuvent être effectuées avec d’autres programmes. 12 Configuration du port COM 1. Cliquez sur le bouton Com.Port sur la barre d’outils pour saisir un paramètre de port COM. 2. Configurez le port RS-232 et les paramètres associés : la vitesse de transmission (Baud rate), les bits de données (Data bits), la parité (Parity) et les bits d’arrêt (Stop bits). 3. Cliquez sur OK pour enregistrer le paramètre ou sur Cancel pour quitter ou annuler le réglage. Affichage des statistiques 1. Cliquez sur le bouton Statistics (Statistiques) sur la barre d’outils pour afficher les statistiques sous forme d’histogramme. Cet exemple montre la valeur relevée pour un thermomètre à double entrée. Dans cet exemple : • L’histogramme des températures T1 et T2 apparaît sur la fenêtre secondaire. • La gamme des températures T1 et T2 peut être définie sur 4 à 20 divisions. • L’histogramme est automatiquement modifié lorsque la gamme des températures est remise à zéro. 13 • • • Valeurs maximum, minimum , moyenne et écart type. L’écart type (Std.Dev) est automatiquement calculé et affiché (en bas à droite sur l’écran. Lorsque vous utilisez l’anémomètre TMA-10, l’affichage des statistiques indique la température et les valeurs du débit d’air relevées. Utilisez le réglage Interval pour modifier l’intervalle affiché sur l’écran. Impression d’un graphique 1. Cliquez sur le bouton Print Graph (Imprimer le graphique) sur la barre d’outils. 2. Pour changer d’imprimante, cliquez sur Properties (Propriétés) et sélectionnez l’imprimante voulue. 3. Pour changer les caractéristiques du papier, saisissez les paramètres voulus dans Graphics Options (Options graphiques). Contrôle d’une séance de mesure Réglage de la centrale de mesure Le logiciel TM-SW fournit deux options d’enregistrement des mesures : données d’échantillonnage avec Sample Data et vitesse d’échantillonnage avec Sample Rate. Résultats d’échantillonnage : 2000 ; 4000 ; 8000 ; 16.000 enregistrements. Taux d’échantillonnage (seconde) : 1 à 3600. Si la vitesse saisie est hors gamme, le graphique Out of Range (Hors gamme) qui s’affiche indique les valeurs minimum et maximum pour ce champ. • Cliquez sur les flèches haut ou bas pour modifier le nombre de résultats d’échantillonnage et le taux d’échantillonnage. 14 Enregistrement • Cliquez sur le bouton Start pour lancer l’enregistrement en ligne des mesures. Cliquez sur le bouton End (Fin) pour arrêter l’enregistrement Décalage YOFFSET et gain YGAIN L’option YGAIN règle le gain du signal entre les divisions de l’axe Y et l’option de décalage YOFFSET permet de décaler l’axe du zéro selon le chiffre défini sur le bouton. Si le signal varie par exemple de 71 à 73 et si zéro est au centre du graphique avec une valeur YGAIN de 10 ( + 10 divisions), la trace se limite à un trait étroit au sommet du graphique. En modifiant le gain YGAIN sur 5 et le décalage YOFFSET sur + 5, l’axe Y du graphique est compris entre 25 et 75 et le signal est 2,5 fois plus grand, facilitant ainsi l’identification des variations de lecture plus réduites • Cliquez sur le paramètre souhaité pour modifier la gamme YOFFSET et YGAINS. Configuration du seuil d’alarme 1. Cliquez sur le bouton Alarm SW pour régler les seuils d’alarme basse Alarm Low et haute, Alarm High. 2. Cliquez sur les flèches haut et bas pour choisir le réglage du seuil bas Low Limit et haut High Limit. 3. Cliquez de nouveau sur le bouton Alarm SW pour enregistrer vos paramètres. 15 Affichage de la gamme (Display Range) Règle le nombre d’enregistrements à afficher. Vous pouvez définir 5 gammes : 0,5K (500) : 1 K (1000) ; 2 K (2000) ; 4 K (4000) ; et 8 K (8000). • Cliquez sur le paramètre souhaité pour modifier la gamme à afficher. Assistance clientèle Pour tout problème concernant ce produit ou pour contacter Meterman Test Tools : Aux Etats-Unis Au Canada Adresse postale européenne* Meterman Test Tools Meterman Test Tools Meterman Test Tools Europe th 1420 75 Street SW 400 Britannia Rd. E. Unit #1 P.O. Box 1186 Everett, WA 98203 Mississauga, Ontario L4Z 1X9 5602 B.D. Eindhoven Tél. : 877-596-2680 Tél. : 877-596-2680 Pays-Bas Fax : 425-446-6390 Fax : 905-890-6866 *(Réservée à la correspondance. Nos clients européens doivent contacter leur distributeur). 16 TM-SW-Schnittstellensoftware Einleitung ...........................................................................................................................................................2 TM-SW-Merkmale................................................................................................................. .............................2 Paketinhalt ......................................................................................................................................................2 Installation .........................................................................................................................................................2 Soft- und Hardwareanforderungen.................................................................................................................2 Installation der TM-SW-Software ................................................................................................ ...................2 Verwendung der TM-SW-Software.................................................................................................. ..................3 Starten der Software........................................................................................................... ............................3 Abrufen einer Datei .........................................................................................................................................4 Speichern einer Datei.......................................................................................................... ............................4 Einrichten des COM-Anschlusses................................................................................................. ..................5 Anzeigen von Statistik.....................................................................................................................................5 Drucken einer Grafik ........................................................................................................... ............................6 Steuerung der Aufzeichnungssitzung ............................................................................................. ...................6 Datenlogger-Einstellung (Logger Setting)....................................................................................... ...............6 Aufzeichnung (Recording)..............................................................................................................................7 Y-OFFSET und Y-GAIN....................................................................................................................................7 Einstellen der Alarm-Grenzwerte ................................................................................................ ....................7 Anzeigebereich (Display Range)................................................................................................. ....................8 Kundendienst .....................................................................................................................................................8 17 Deutsch Inhalt Einleitung Die TM-SW-Software und das RS-232-Kabel wird mit Modellen des TMD90 Thermometers und des TMA10 Anemometers für Echtzeit-Datenerfassung von Messergebnissen verwendet. Die Daten können für weitere Analysen, Datenberichte und grafische Datendarstellungen auf einem Computer gespeichert werden. TM-SW-Merkmale • • • • • Bis zu 16'000 Messwerte mit Echtzeit-Datum-Zeitstempel. Programmierbares Intervall von 1 bis 3'600 Sekunden. Benutzerdefinierte Maximal (High)- und Minimal (Low)-Alarmeinstellungen. Ermöglicht weitere Analysen durch Herunterladen von Daten auf einen Computer. Zur Unterstützung von Datenanalysen und Prozesslenkung werden alle Daten im Textformat (.txt) gespeichert und können daher einfach zur Verwendung in anderen Softwareanwendungen übertragen werden. Paketinhalt • • • CD-ROM RS-232-Kabel mit Sub-D-Stecker Bedienungshandbuch Installation Soft- und Hardwareanforderungen Betriebssystem Windows 95/98/NT/2000//ME/XP mit einem seriellen COM1 oder COM2-Anschluss. Installation der TM-SW-Software 1. Die CD in das CD-ROM-Laufwerk einlegen. 2. Im TM-SW-Menü auf die Schaltfläche Install Software (Software installieren) klicken. 3. Den auf dem Bildschirm eingeblendeten Installationsanweisungen folgen. 18 Verwendung der TM-SW-Software Starten der Software 1. Den RS-232-Anschluss in das Messgerät einführen und das Kabel am COM-Anschluss des PCs anschließen. 2. Auf der Windows-Taskleiste Start, Programs, Handheld und dann nochmals Handheld auswählen. 3. Der Datenlogger-Bildschirm des Handheld-Messgeräts wird eingeblendet. Wenn kein Messgerät angeschlossen ist, sind die Eingangsanschlüsse als „Undefined“ (nicht definiert) bezeichnet. Ein Beispielbildschirm ist unten abgebildet. 19 Abrufen einer Datei 1. Auf der Symbolleiste auf die Schaltfläche Retrieve File (Datei abrufen) klicken. 2. Auf den Ordner doppelklicken, der das zu öffnende Dokument enthält. Auf den Dokumentnamen klicken und dann auf OK klicken. 3. Alle Dokumente weisen den Dateityp .txt auf, keine anderen Dateitypen sind gültig. Speichern einer Datei Auf der Symbolleiste auf die Schaltfläche Save File (Datei speichern) klicken. Aufgezeichnete Daten können auch unter einem neuen Namen gespeichert werden. Dazu auf die Schaltfläche Save File (Datei speichern) klicken und einen neuen Namen in das Dateinamenfeld eingeben. Nach der Speicherung der Datei können mit anderen Programmen weitere statistische Auswertungen oder Analysen durchgeführt werden. 20 Einrichten des COM-Anschlusses 1. Auf der Symbolleiste auf die Schaltfläche Com.Port (COM-Anschluss) klicken, um die Einstellungen des COM-Anschlusses einzurichten. 2. Den RS-232-Anschluss und zugehörige Einstellungen einrichten: zum Beispiel Baud Rate (Baudrate), Data Bits (Datenbits), Parity (Parität) und Stop Bits (Stoppbits). 3. Auf OK klicken, um die Einstellung zu speichern, oder auf Cancel (Abbrechen) klicken, um die Einstellung abzubrechen bzw. zu beenden. Anzeigen von Statistik 1. Auf der Symbolleiste auf die Schaltfläche Statistics (Statistik) klicken, um Statistikdaten im Histogrammformat anzuzeigen. Dieses Beispiel zeigt die Messwerte eines Dual-Input-Thermometers. In diesem Beispiel: • Zeigt der sekundäre Bildschirm Temperatur T1 und Temperatur T2 Histogramm an. • Die Temperaturbereiche T1 und T2 können von 4 Teilungen bis 20 Teilungen eingerichtet werden. • Histogramm wird automatisch verändert, sobald der Temperaturbereich neu gesetzt wird. 21 • • • Maximum (Höchstwert), Minimum (Niedrigstwert), Mean (Mittelwert) und Std. Dev (Standardabweichung) werden automatisch berechnet und auf der linken Seite des Bildschirms angezeigt. Wenn das TMA10 Anemometer verwendet wird, zeigt die Statistikanzeige Temperatur- und Luftflussmesswerte an. Zum Ändern des Anzeigeintervalls auf dem Bildschirm die Intervallsteuerung verwenden. Drucken einer Grafik 1. Auf der Symbolleiste auf die Schaltfläche Print Graph (Grafik drucken) klicken. 2. Um den Drucker zu wechseln, auf Properties (Eigenschaften) klicken und dann einen Zieldrucker auswählen. 3. Um die Papierspezifikationen zu ändern, die gewünschten Einstellungen unter „Graphics Options“ (Grafikoptionen) eingeben. Steuerung der Aufzeichnungssitzung Datenlogger-Einstellung (Logger Setting) Die TM-SW-Software unterstützt zwei Datenlogger-Einstellungen: „Sample Data“ und „Sample Rate“. Sample Data: 2000, 4000, 8000 und 16000 Datensätze. Sample Rate: 1 bis 3600 Sekunden. Wenn die eingegebene Rate außerhalb des gültigen Bereichs liegt, wird eine „Out of Range“-Meldung mit den Minimum- und Maximumwerten für dieses Feld eingeblendet. • Zum Ändern der Einstellungen „Sample Data“ und „Sample Rate“ auf den Aufwärts- bzw. Abwärtspfeil klicken. 22 Aufzeichnung (Recording) • Auf die Schaltfläche Start (Starten) klicken, um die Online-Aufzeichnung von Messungen zu starten. Auf die Schaltfläche End (Beenden) klicken, um die Aufzeichnung zu stoppen. Y-OFFSET und Y-GAIN Y-GAIN (Y-Verstärkung) legt die Signalmenge zwischen Y-Achse-Teilungen fest. Y-OFFSET (Y-Offset) ermöglicht das Verschieben der Nullachse entsprechend der Zahl auf dem Knopf. Schwankt beispielsweise ein Signal zwischen 71 und 73, und die Nullachse auf dem Diagramm ist auf einen Y-GAIN-Wert von 10 ( + 10 Teilungen) gesetzt, dann ist die Kurve auf einen schmalen Bereich oben im Diagramm beschränkt. Wenn YGAIN auf 5 und Y-OFFSET auf + 5 verändert werden, liegt die Y-Achse zwischen 25 und 75, und das Signal ist 2,5 Mal größer, wodurch kleine Messschwankungen einfacher zu sehen sind. • Auf die gewünschte Einstellung klicken, um den Y-OFFSET- und Y-GAIN-Bereich zu ändern. Einstellen der Alarm-Grenzwerte 1. Auf den Knopf „Alarm SW“ klicken, um die Grenzwerte „Alarm High“ und „Alarm Low“ einzustellen. 2. Auf den Aufwärts- bzw. Abwärtspfeil um den Höchstwert und den Niedrigstwert festzulegen. 3. Nochmals auf den Knopf „Alarm SW“ klicken, um die Einstellungen zu speichern. 23 Anzeigebereich (Display Range) Legt die Anzahl der anzuzeigenden Datensätze fest. Zur Auswahl stehen 5 Bereiche: 0,5 K (500), 1 K (1000), 2 K (2000), 4 K (4000) und 8 K (8000). • Auf die gewünschte Einstellung klicken, um den Anzeigebereich zu ändern. Kundendienst Bei Problemen mit diesem Produkt Meterman Test Tools benachrichtigen: In den USA: In Kanada: Meterman Test Tools Meterman Test Tools 1420 75th Street SW 400 Britannia Rd. E. Unit #1 Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel.: 877-596-2680 Tel.: 877-596-2680 Fax: 425-446-6390 Fax: 905-890-6866 Korrespondenzanschrift für Europa* Meterman Test Tools Europe P. O. Box 1186 5602 BD Eindhoven Niederlande *(Nur Korrespondenz. Kunden in Europa wenden sich an den zuständigen Distributor.) 24 Software di interfaccia TM-SW Introduzione.......................................................................................................................................................2 Caratteristiche del software TM-SW............................................................................................. .....................2 Contenuto della confezione.............................................................................................................................2 Installazione .......................................................................................................................................................2 Requisiti hardware..........................................................................................................................................2 Installazione del software TM-SW ............................................................................................... ...................2 Uso del software TM-SW......................................................................................................... ..........................3 Avvio del software............................................................................................................. ..............................3 Reperimento di un file.....................................................................................................................................4 Salvataggio di un file......................................................................................................... ..............................4 Impostazione della porta COM................................................................................................... .....................5 Visualizzazione dei dati statistici............................................................................................ .........................5 Stampa di un grafico.......................................................................................................................................6 Controllo delle sessioni di registrazione............................................................................................................6 Impostazione del registro ...............................................................................................................................6 Registrazione ..................................................................................................................................................7 Parametri YOFFSET e YGAINS........................................................................................................................7 Impostazione del limite di allarme..................................................................................................................7 Parametro Display Range (Portata del display)..............................................................................................8 Supporto clienti..................................................................................................................................................8 25 Italiano Indice Introduzione Il software TM-SW e il cavo RS-232 vengono usati con i termometri modello TMD90 e gli anemometri modello TMA10 per l’acquisizione in tempo reale dei dati e dei risultati delle misure, che possono in seguito essere memorizzati in un computer per ulteriori analisi, relazioni e grafici. Caratteristiche del software TM-SW • • • • • Fino a 16.000 letture di campioni con marcatura temporale in tempo reale. Intervallo di campionamento programmabile da 1 a 3.600 secondi. Limiti di allarme minimo e massimo definiti dall’utente. Possibilità di analisi ulteriori mediante lo scaricamento di dati in un programma software. Per agevolare l’analisi dei dati e il controllo dei processi, tutti i dati sono salvati in formato di testo (.txt) e possono essere facilmente elaborati per l’uso con altre applicazioni software. Contenuto della confezione • • • CD-ROM Cavo RS-232 con connettore Sub-D Manuale d’uso Installazione Requisiti hardware Sistema operativo Windows 95/98/NT/2000//ME/XP con porta seriale COM1 o COM2. Installazione del software TM-SW 1. Inserire il CD nell’apposita unità. 2. Fare clic sul pulsante Install Software (Installa il software) nel menu TM-SW. 3. Seguire le istruzioni di installazione sullo schermo. 26 Uso del software TM-SW Avvio del software 1. Inserire il connettore RS-232 nello strumento e collegare il cavo alla porta COM del PC. 2. Nella barra delle applicazioni di Windows, selezionare Start (Avvio), Programs (Programmi), Handheld (Palmare) e di nuovo Handheld. 3. Appare lo schermo Data Logger (Registro dati) dello strumento palmare. Se non è stato collegato alcun multimetro, le porte di ingresso risultano “undefined” (indefinite). Di seguito è illustrato un esempio di questo schermo. 27 Reperimento di un file 1. Fare clic sul pulsante Retrieve File (Reperisci file) sulla barra degli strumenti. 2. Fare doppio clic sulla cartella che contiene il documento da aprire. Fare clic sul nome del documento e quindi su OK. 3. Tutti i documenti sono nel formato di testo .txt; non sono ammessi altri tipi di file. Salvataggio di un file Fare clic sul pulsante Save File (Salva file) sulla barra degli strumenti. È anche possibile memorizzare con un nome diverso i dati registrati: fare clic su Save File e digitare il nuovo nome nel campo File name (Nome file). Dopo il salvataggio del file, si possono effettuare ulteriori elaborazioni statistiche e analisi con altri programmi. 28 Impostazione della porta COM 1. Fare clic sul pulsante Com.Port (Porta COM) sulla barra degli strumenti per accedere alle impostazioni della porta COM. 2. Impostare la porta RS-232 e i relativi parametri, quali Baud rate (Velocità di trasmissione), Data bits (Bit di dati), Parity (Parità) e Stop bits (Bit di stop). 3. Fare clic su OK per memorizzare l’impostazione o su Cancel (Annulla) per uscire senza salvare le modifiche. Visualizzazione dei dati statistici 1. Fare clic sul pulsante Statistics (Statistiche) sulla barra degli strumenti per visualizzare un istogramma dei dati statistici. Questo esempio illustra i valori rilevati da un termometro a due ingressi: • lo schermo secondario presenta gli istogrammi di temperatura T1 e T2; • le gamme di temperatura T1 e T2 possono essere definite fra 4 e 20 divisioni; • l’istogramma si aggiorna automaticamente una volta completata la ridefinizione della gamma di temperatura; • i valori massimo, minimo, medio e la deviazione standard sono calcolati automaticamente e visualizzati sul lato destro dello schermo nei campi Maximum, Minimum, Mean e Std.Dev; 29 • • quando si usa l’anemometro TMA-10, la visualizzazione statistica mostra i valori relativi alla temperatura e al flusso d’aria; gli intervalli visualizzati sullo schermo possono essere modificati con i comandi Intervals. Stampa di un grafico 1. Fare clic sul pulsante Print Graph (Stampa grafico) sulla barra degli strumenti. 2. Per cambiare la stampante, fare clic su Properties (Proprietà) e selezionare la stampante di destinazione. 3. Per cambiare le proprietà della carta, definire i parametri nella sezione Graphics Options (Opzioni grafica). Controllo delle sessioni di registrazione Impostazione del registro Il software TM-SW offre due impostazioni di registrazione dei dati: dati di campionamento e frequenza di campionamento. L’impostazione Sample data (Dati di campionamento) permette di registrare 2.000, 4.000, 8.000 o 16.000 record. L’impostazione Sample rate (Sec.) [Frequenza di campionamento (secondi)] accetta valori da 1 a 3600. Se la frequenza immessa è fuori gamma, il display visualizza un grafico “Out of Range” che indica i valori minimo e massimo dell’impostazione. • Fare clic sulla freccia in su o in giù per cambiare i valori dei campi Sample Data e Sample Rate. 30 Registrazione • Fare clic sul pulsante Start (Avvio) per iniziare la registrazione online delle misure; fare clic su End (Fine) per terminarla. Parametri YOFFSET e YGAINS Il parametro YGAINS definisce il guadagno del segnale tra le divisioni dell’asse Y; il parametro YOFFSET permette di spostare lo zero dell’asse in base al numero indicato dal selettore. Ad esempio, se si ha un segnale che varia da 71 a 73 e l’origine del grafico è a zero con un guadagno YGAINS pari a 10 (+10 divisioni), il tracciato mostra una linea pressoché retta lungo la parte superiore dello schermo. Impostando il guadagno YGAINS su 5 e il parametro YOFFSET su +5, l’asse Y del grafico visualizza valori tra 25 e 75 e il segnale risulta 2,5 volte più ampio, rendendo maggiormente visibili le variazioni minori. • Modificare i parametri YOFFSET e YGAINS facendo clic sull’impostazione desiderata. Impostazione del limite di allarme 1. Fare clic sul selettore Alarm SW per impostare i limiti di allarme superiore e inferiore. 2. Fare clic sulle frecce in su e in giù per scegliere i valori massimo e minimo desiderati. 3. Fare clic di nuovo sul selettore Alarm SW per salvare le impostazioni. 31 Parametro Display Range (Portata del display) Determina il numero di record visualizzabili sul display. Le opzioni disponibili sono 5: 0,5k (500), 1k (1.000), 2k (2.000), 4k (4.000) e 8k (8.000). • Modificare la portata del display facendo clic sull’impostazione desiderata. Supporto clienti In caso di problemi o per qualsiasi altro quesito riguardante il prodotto, rivolgersi alla Meterman Test Tools agli indirizzi e ai numeri seguenti: U.S.A. Canada Recapito postale europeo* Meterman Test Tools Meterman Test Tools Meterman Test Tools Europe 1420 75th Street SW 400 Britannia Rd. E. Unit #1 P.O. Box 1186 Everett, WA 98203 Mississauga, ON L4Z 1X9 5602 BD Eindhoven Tel: 877 596 2680 Tel: 877 596 2680 Paesi Bassi Fax: +1 425 446 6390 Fax: +1 905 890 6866 *(Solo per corrispondenza. Si pregano i clienti europei di rivolgersi al proprio rivenditore.) 32 Software para interfaz TM-SW Introducción.................................................................................................................................................................2 Funciones del TM-SW............................................................................................................ ......................................2 Contenido del módulo...............................................................................................................................................2 Instalación....................................................................................................................................................................2 Requisitos de hardware ............................................................................................................................................2 Instalación del software TM-SW................................................................................................. ..............................2 Empleo del software TM-SW ...................................................................................................... .................................3 Inicio del software............................................................................................................ .........................................3 Recuperación de un archivo ..................................................................................................... ................................4 Procedimiento para guardar un archivo .......................................................................................... .........................4 Configuración del puerto COM .................................................................................................................................5 Visualización de estadísticas ....................................................................................................................................5 Impresión de un gráfico............................................................................................................................................6 Control de la sesión del registrador.............................................................................................................................6 Configuración del registrador ...................................................................................................................................6 Registro ....................................................................................................................................................................7 DESPLAZAMIENTO Y y GANANCIA Y.......................................................................................................................7 Configuración del límite de alarma ...........................................................................................................................7 Rango de exhibición .................................................................................................................................................8 Servicio de asistencia a clientes .............................................................................................. ....................................8 33 Español Contenido Introducción El software TM-SW y el cable RS-232 se utilizan con los modelos TMD90 termómetro y TMA10 anemómetro para la adquisición en tiempo real de los datos correspondientes a los resultados de sus mediciones. Usted los puede almacenar en su computadora para seguir analizándolos o realizar informes de datos o graficación. Funciones del TM-SW • • • • • Hasta 16.000 lecturas de muestras con estampado de fecha y hora en tiempo real. Intervalo de muestras programable entre 1 y 3.600 segundos. Configuraciones de alarma máxima (alta) y mínima (baja) definibles por el usuario. Permite análisis adicionales descargando datos a un programa de computación. Para asistir con el análisis de los datos y el control del proceso, toda la información es guardada en formato de texto (.txt) y puede ser fácilmente transformada para su empleo por otras aplicaciones de software. Contenido del módulo • • • CD-ROM Cable RS-232 con conector Sub-D Manual del usuario Instalación Requisitos de hardware Sistemas operativos Windows 95/98/NT/2000//ME/XP con un puerto serie disponible COM1 o COM2. Instalación del software TM-SW 1. Inserte el CD en su unidad de disco CD-ROM. 2. Haga clic sobre el botón Install Software (Instalar software) del menú TM-SW. 3. Siga las instrucciones de instalación que aparecen en la pantalla. 34 Empleo del software TM-SW Inicio del software 1. Inserte el conector RS-232 en el multímetro y conecte el cable al puerto COM de su PC. 2. Desde la barra de tareas de Windows, seleccione Start (Inicio), Programs (Programas), Handheld, luego nuevamente Handheld. 3. Aparecerá la pantalla de registro de datos del multímetro portátil. Si no hay un multímetro conectado, los puertos de entrada estarán rotulados como no definidos. A continuación, se provee una pantalla de muestra. 35 Recuperación de un archivo 1. Haga clic sobre el botón Retrieve File (Recuperar archivo) de la barra de herramientas. 2. Haga doble clic sobre la carpeta que contiene el documento que desea abrir. Haga clic sobre el nombre del documento, y luego haga clic sobre OK (Aceptar). 3. Todos los documentos están en archivos de tipo .txt; ningún otro tipo de archivo es válido. Procedimiento para guardar un archivo Haga clic sobre el botón Save File (Guardar archivo) de la barra de herramientas. Usted puede también guardar la información registrada bajo un nuevo nombre haciendo clic sobre Save File (Guardar archivo) y escribiendo un nuevo nombre en el campo Nombre de archivo. Luego de guardar el archivo, pueden realizarse más estadísticas o análisis con otros programas. 36 Configuración del puerto COM 1. Para ingresar una configuración del puerto COM, haga clic sobre el botón Com.Port (Puerto Com) de la barra de herramientas. 2. Configure el puerto RS-232 y configuraciones asociadas tales como velocidad en baudios, bits de datos y bits de paridad y parada. 3. Haga clic sobre OK (Aceptar) para guardar la configuración o Cancel (CANCELAR) para salir o para cancelar la configuración. Visualización de estadísticas 1. Haga clic sobre el botón Statistics (Estadísticas) de la barra de herramientas para ver estadísticas en formato de histograma. Este ejemplo muestra la lectura para un termómetro de doble entrada. En este ejemplo: • En la pantalla secundaria usted verá el Histograma de Temperatura T1 y Temperatura T2. • El rango de las temperaturas T1 y T2 puede ser establecido desde 4 divisiones hasta 20 divisiones. 37 • • • • El histograma será modificado automáticamente una vez que se modifique el rango de temperaturas. Máximo, Mínimo , Medio y Estándar. La Dev (Desviación estándar) es calculada automáticamente y exhibida en el costado derecho de la pantalla. Cuando se utiliza el anemómetro TMA-10, la exhibición de estadísticas mostrará lecturas de temperatura y flujo de aire. Utilice el control de intervalo para cambiar el intervalo exhibido en la pantalla. Impresión de un gráfico 1. Haga clic sobre el botón Print Graph (Imprimir gráfico) de la barra de herramientas. 2. Para cambiar impresoras, haga clic sobre Properties (Propiedades) y luego seleccione una impresora de destino. 3. Para cambiar especificaciones del papel, ingrese las configuraciones deseadas en Opciones gráficas. Control de la sesión del registrador Configuración del registrador Existen dos configuraciones de registro de datos provistas en el software TM-SW: los datos de muestra y la frecuencia de muestreo. Datos de muestra: 2.000, 4.000, 8.000 y 16.000 registros. Frecuencia de muestreo (segunda): 1 a 3600. Si la frecuencia que se ingresa está fuera de rango, aparecerá un gráfico de fuera de rango que muestra los valores mínimo y máximo para este campo. • Haga clic sobre los botones de flecha arriba o flecha abajo para cambiar las configuraciones de muestras de datos y de frecuencia de muestreo. 38 Registro • Haga clic sobre el botón Start (Inicio) para iniciar el registro en línea de las mediciones. Haga clic sobre el botón End (Finalizar) para detener el registro DESPLAZAMIENTO Y y GANANCIA Y La YGAIN (GANANCIA Y) establece la cantidad de señal entre divisiones del eje Y y el YOFFSET (DESPLAZAMIENTO Y) le permite desplazar el eje cero según el número presente en la perilla. Por ejemplo, si usted tiene una señal que varía de 71 a 73 y tiene centro cero en el gráfico con una YGAIN (GANANCIA Y) de 10 ( + 10 divisiones), la traza está limitada a una línea angosta cerca de la parte superior del gráfico. Modificando la YGAIN (GANANCIA Y) a 5 y el YOFFSET (DESPLAZAMIENTO Y) a + 5, el eje Y del gráfico es 25 a 75 y la señal es 2,5 veces mayor, haciendo más sencillo visualizar variaciones más pequeñas de lectura • Haga clic sobre la configuración deseada para cambiar el rango de YOFFSET (DESPLAZAMIENTO Y) y YGAIN (GANANCIA Y). Configuración del límite de alarma 1. Haga clic sobre la perilla de alarma SW para configurar los límites de alarma alta y alarma baja. 2. Haga clic sobre los botones de flecha arriba y flecha abajo para seleccionar la configuración de los límites alto y bajo. 3. Haga clic nuevamente sobre la perilla de alarma SW para guardar sus configuraciones. 39 Rango de exhibición Establece el número de registros a ser exhibidos. Hay 5 rangos que se pueden establecer: 0,5 K (500), 1 K (1.000), 2 K (2.000), 4 K (4.000) y 8 K (8.000). • Haga clic sobre la configuración deseada para cambiar el rango de exhibición. Servicio de asistencia a clientes Para consultar por problemas con este producto o para comunicarse con Meterman Test Tools: En Estados Unidos En Canadá Dirección para envío de correspondencia en Meterman Test Tools Meterman Test Tools Europa* 1420 75th Street SW 400 Britannia Rd. E. Unit #1 Meterman Test Tools Europe Everett, WA 98203 Mississauga, Ontario L4Z 1X9 P.O. Box 1186 Tel.: 877-596-2680 Tel.: 877-596-2680 5602 BD Eindhoven Fax: 425-446-6390 Fax: 905-890-6866 Holanda *(Correspondencia solamente. Los clientes europeos deben ponerse en contacto con su distribuidor). 40 TM-SW TM-SW ® ® ® ® U.S. Service Center RS232 Software and Cable Meterman Test Tools 1420 75th Street SW Everett, WA 98203 Tel: 877-596-2680 Fax: 425-446-4882 For use with Meterman Model TMD90, Digital Thermometer and Model TMA10, Anemometer Canadian Service Center Meterman Test Tools 400 Britannia Rd. E. Unit #1 Mississauga, ON L4Z 1X9 Tel: 877-596-2680 Fax: 425-446-4882 User Manual European Correspondence Address* Meterman Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands *Correspondence only - no repair or replacement available from this address. European customers please contact your distributor. Visit www.metermantesttools.com for • Catalog • Application notes • Product specifications • Product manuals PN 2106913 January 2004 © Wavetek Meterman Test Tools. All rights reserved. Printed in Taiwan. Please Recycle • Mode d'emploi • Bedienungshandbuch • Manuale d'Uso • Manual de uso
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Wavetek 232 Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para