Transcripción de documentos
Owner’s Manual
PDU330AT6L15, PDU330AT6L21
(Series Number: AG-00D5)
3-Phase 1U Monitored Rack PDU
with Automatic Transfer Switch (ATS)
PDU3VD351
(Series Number: AG-00C2)
PDU3V20D354, PDU3V20D354A, PDU3V20D354B
(Series Number: AG-013C)
3-Phase Vertical Power Strip
1. Important Safety
Instructions
2. Installation
2
3
2.1 Mounting the ATS
2.2 Mounting the Power Strip
2.3 Connecting the Power Strip
to the ATS
3
4
5
2.5 Networking the ATS
5
3. Features
4. Digital Display
11
5.1 Navigating Display Menus
and Submenus
11
5.2 Navigating Config Menus
and Submenus
18
6. Configuration and Operation 20
4
2.4 Connecting the ATS
5. Using the Digital Display
6.1 Automatic Transfer Switch
7. Service
8. Warranty and Product
Registration
Español
Français
6
8
20
22
22
24
47
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $50 value!
www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2015 Tripp Lite. All rights reserved.
1
21-03-404-933363.indb 1
4/1/2021 1:09:29 PM
1. Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation, and storage of this product.
Failure to heed these instructions and warnings may affect the
product warranty.
CAUTION Only those who are properly trained or qualified to use this device should
do so. Anyone who is not trained or qualified should not use this device unless it is under the
supervision of someone who is properly trained or qualified to do so.
Children must be supervised to ensure that they do not use the device as a toy.
Never use the device if the cord and plug are damaged; if it is not working properly,
or if it has been dropped or damaged, take it to an authorized service center for inspection and
repair.
If the power cord is damaged, it must be replaced by the manufacturer, its authorized service agent,
or by qualified personnel in order to avoid a danger.
• The Power Strip provides the convenience of multiple outlets, but DOES NOT provide surge or line noise
protection for connected equipment.
• Do not exceed the following equipment ratings:
• Maximum full balanced load is 13.9A per bank when powered by a 3Φ ATS (Automatic Transfer
Switch) with a rated input of 24A.
• Maximum full balanced load is 20A per bank when powered by a 3Φ ATS (Automatic Transfer
Switch) with a rated input of 35A.
• The Automatic Transfer Switch and Power Strip are designed for indoor use only, in a controlled
environment, away from excess moisture, temperature extremes, conductive contaminants, dust or
direct sunlight.
• Keep indoor ambient temperature between 32°F and 104°F (0°C and 40°C).
• The Automatic Transfer Switch and Power Strip must be installed by a qualified technician only.
• Do not attempt to mount the Automatic Transfer Switch or Power Strip to an insecure or unstable
surface.
• Install in accordance with National Electrical Code standards. Be sure to use the proper overcurrent
protection for the installation, in accordance with the plug/equipment rating.
• Connect the Automatic Transfer Switch to an outlet that is in accordance with your local building codes
and that is adequately protected against excess currents, short circuits and earth faults.
• The electrical outlets supplying power to the equipment should be installed near the equipment and
easily accessible.
• Do not connect the Automatic Transfer Switch to an ungrounded outlet or to extension cords or
adapters that eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently installed without a
plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the Power Strip should not draw more current than the individual
outlet’s rating.
• The total load connected to the Power Strip must not exceed the maximum load rating for the
Automatic Transfer Switch.
• Do not attempt to modify the Automatic Transfer Switch’s or Power Strip’s input plugs or power cables.
• Do not drill into or attempt to open any part of the Automatic Transfer Switch or Power Strip housing.
There are no user-serviceable parts inside.
• Do not attempt to use the Automatic Transfer Switch or Power Strip if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment can reasonably be
expected to cause the failure of the life support equipment or to significantly affect its safety or
effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
2
21-03-404-933363.indb 2
4/1/2021 1:09:29 PM
2. Installation
2.1 Mounting the Automatic Transfer Switch (ATS)
Important: The ATS should be installed onto the rack rails in the lowest U space available
(height < 36 in./1 m).
Mount your equipment in a 4-post rack or rack enclosure. The user must determine the fitness of
hardware and procedures before mounting. If hardware and procedures are not suitable for your
application, contact the manufacturer of your rack or rack enclosure. The procedures described in this
manual are for common rack and rack enclosure types and may not be appropriate for all applications.
Note: Each snap-in slide rail assembly consists of a sliding rack enclosure mounting bracket and an inner
channel rail. For ease of installation, the inner channel rails come pre-attached to the ATS unit.
1 Align the rear bracket’s tabs with the rack
enclosure’s square mounting holes and
push the metal hooks through the
mounting holes 1A . Then push the rear
bracket toward the enclosure support for
the blue tabs snap the mount into place
1B . Then align the front bracket’s tabs
with the rack enclosure’s front square
mounting holes. Push the front bracket’s
metal hooks through the mounting holes
and push the front bracket toward the
enclosure support for the blue tabs to
snap the mount into place. Make sure
to install the mounting bracket into
the lowest U space.
1A
2 Repeat step one for the second mounting
bracket on the opposite side of the rack
enclosure.
1B
3 Once both mounting brackets are fixed
onto the rack enclosure, secure the rear
brackets using the included M5X10L
screws.
4 Align the inner channel rails attached to
the ATS with the mounting brackets. Then
slide the unit into the rail assembly. Using
a screwdriver, secure the ATS’s panelmounted thumb screws to the rack
enclosure.
3
4
3
21-03-404-933363.indb 3
4/1/2021 1:09:30 PM
2. Installation
2.2 Mounting the Power Strip
Note: Mounting buttons come pre-installed to the
Power Strip for toolless mounting. A second set of
button mounting holes on the power strip allow
alternate positioning in the rack.
Position the Power Strip as desired within the
rack enclosure, align the buttons with the rack
mounting slots and slide the Power Strip
downward into position.
Your model may differ slightly from image.
2.3 Connecting the Power Strip to the ATS
The power strip has a 7 conductor cord with an
8-position plug. The plug installs directly to the
ATS mating receptacle on the back of the unit.
Your model may differ slightly from image.
4
21-03-404-933363.indb 4
4/1/2021 1:09:31 PM
2. Installation
2.4 Connecting the ATS
2.4.1 Connect ATS Input Plugs
Note: The ATS comes equipped with two 3-Phase AC
power inputs: Source A and Source B. Source A is
the default preferred (primary) source. See
Navigating Config Menus and Submenus section
for instructions on changing the preferred source. The
connection instructions below assume Source A is the
preferred source.
A
B
Connect the Source A input plug A to a
preferred 3-Phase AC power source. Under
normal operating conditions, the ATS will
distribute AC power from the Source A input
source. Connect the Source B input plug B to
an alternative source of grounded AC power.
Do not plug the Source B input into the same
power source as the Source A input. The ATS
will distribute AC power from the Source B
input only if the Source A input becomes
unavailable or unstable.
2.4.2 Connect Equipment
to Power Strip
Do not exceed the load rating of the power
strip. The total electrical current used by each
phase of the power strip will be displayed in
amperes on the digital meter.
2.5 Networking the ATS
Your ATS can receive its IP address assignment via DHCP server (dynamic) or static (manual)
addressing methods. If you are uncertain which method to use, contact your network administrator
for assistance before continuing the configuration process.
Note: The MAC address (12-digit string in this format: 000667xxxxxx) is printed on a label and attached to the ATS
enclosure. For static IP address assignment, use the DB9 configuration cable (730866) included with the ATS.
The ATS provides remote monitoring and more via Web browser, telnet and SNMP-based Network
Management Systems. For more information about configuration and operation of the ATS via the
PowerAlert Web browser interface, refer to the SNMPWEBCARD User's Guide by going to
www.tripplite.com/support and typing SNMPWEBCARD into the search field.
5
21-03-404-933363.indb 5
4/1/2021 1:09:32 PM
3. Features
Power Strip
(PDU3VD351 , PDU3V20D354, PDU3V20D354A, PDU3V20D354B)
2 11
1
ATS Automatic Transfer Switch (PDU330AT6L15/PDU330AT6L21)
4
11
5
10
3
12
8
7
9
6
1 Power Strip Outlets: These single-phase IEC C13 and C19 outlets receive power from the
interlaced 3-phase power input connections of Source A or Source B of the ATS. These
outlets are not controllable.
2 Power Strip Input Power Cord: The 7-conductor cord has an
8-position connector that attaches directly to the ATS.
6
21-03-404-933363.indb 6
4/1/2021 1:09:35 PM
3. Features
3 ATS Source A and Source B Input: The cords are
permanently attached to the ATS and have L15-30P or L2130P plugs.
4 Digital Display: Shows source status, measured values, display
modes and other information. See the Digital Display section
for detailed explanations of the indicators and displays.
L15-30P
5 SNMP Reset Button: Press the reset button for 3 seconds to
reboot the ATS network card. Rebooting the network card will
not erase network settings or interrupt AC power. The reset
button is recessed. Use a paper clip or other suitable object to
press it.
L21-30P
6
A
B
Network Interface: Use the RJ-45 jack to connect the ATS to the network
with a standard Ethernet patch cable. The Status LED A and Link LED B
indicate operating conditions as shown in the table below. These ports are
not compatible with PoE (Power Over Ethernet) applications.
Network Operating Conditions
A Status LED Color
B Link LED Color
Off
Card Not Initialized
Off
No Network Connection
Steady Green
Card Initialized and Operational
Flashing Amber
100 Mbps Network Connection
Flashing Amber
Error - Card Not Initialized
Flashing Green
10 Mbps Network Connection
7 DB9 Configuration Port: Use this port to provide direct terminal connection to a computer
with a terminal emulation program. A serial cable is included with the ATS. If you need to
order a replacement cable, contact Tripp Lite Customer Support at www.tripplite.com/support.
8 IEC-320-C13 Convenience Outlet: This outlet receives power from phase L1-L2, but is not
controllable. It contributes to the total L1-L2 load.
9 IEC-320-C13 Convenience Outlet Circuit Breakers: There are two thermal breakers to
protect each side of the convenience outlet.
10 Circuit Breaker: Each single phase output load has its own magnetic breaker. If the
connected equipment load exceeds the maximum load rating for that phase, the circuit
breaker will trip. Disconnect excess equipment before resetting the breaker(s).
11 Chassis Ground Screw: Use this to connect equipment that requires a chassis ground.
12 ATS Mating Receptacle: This receptacle only accepts the 8-position connector on the power
strip input power cord.
7
21-03-404-933363.indb 7
4/1/2021 1:09:35 PM
4. Digital Display
3
1
2
5
4
6
7
8
1 Source Status LEDs: Lit LED patterns indicate which source is preferred, which source is
available for use, and which source is currently being used. See Source Status LED
Indicators section for an explanation of the LED patterns.
2 Breaker Trip LED: Lit when a breaker has tripped.
3 3-Digit Display: Shows measured or calculated values such as Amperage, Kilowatts, Voltage,
Power Unbalance Percentage, Frequency, Power Factor and Temperature.
4 Enter Button: When a menu is selected using the Mode Button, the Enter Button scrolls
through the submenus within each category. Submenus are shown by the Indicator LEDs.
Note: Pushing the Enter and Mode button simultaneously for 2 seconds displays the IP address.
5 Indicator LEDs: Lit LED indicates which value is being displayed on the 3-digit screen.
Amps (A): The input current on the selected Source Input (A# or b#) or Output Load Circuit
(C#) is displayed in amps.
Wattage (kW): The Output Power for the selected Output Load Circuit (C#) or Total Output
Power (OP) is displayed in kW.
Voltage (V): The Source A or B Input Phase-to-Phase voltage (A# or b#) or Output Load
Circuit voltage (C#) is displayed in volts.
Frequency (Hz): Source Input A or B frequency is displayed in Hz.
Power Factor (PF): Output Load power factor is displayed as a decimal (from 0 to 1.00).
8
21-03-404-933363.indb 8
4/1/2021 1:09:35 PM
4. Digital Display
6 2-Digit Display: This display indicates which display mode is selected: Source Input Phase
(A# or b#), % Unbalanced (Ub), Output Circuits (C#), Total Output Power (OP), Temperature
(tC or tF), or Fault Code (FC).
Source A Phases (A#): Displays measurements for Source A. They include phase current
(A), Voltage (V) and Frequency (Hz).
Source B Phases (b#): Displays measurements for Source B. They include phase current
(B), Voltage (V) and Frequency (Hz).
% Unbalanced (Ub): The display shows the unbalanced load percentage deviance from the
average measured value. The percentage for the phase with the highest deviance is displayed.
Output Circuits (C#): Displays measurements for Output Circuit. They include Current (A),
Kilowatts (kW), Voltage (V) and Power Factor (PF).
Total Output Power (OP): Displays total power on all output circuits.
Temperature (t): The ambient temperature is displayed when this option is selected. The
temperature is displayed in Celsius by default, but can be switched to Fahrenheit.
Fault Code (FC): The Fault Code will only display if a breaker has tripped.
7 Mode Button: Scroll through the Display and Config menus using this button. Display menu
choice is shown on 2-digit display. Config menu choice is shown on 3-digit display.
8 SNMP Reset Button: Press the reset button for three seconds to reboot the ATS network
card. Rebooting the network card will not erase network settings or interrupt AC power. The
reset button is recessed. Use a paper clip or other suitable object to perform a reset.
9
21-03-404-933363.indb 9
4/1/2021 1:09:36 PM
4. Digital Display
Source Status LED Indicators
LED pattern
Description
Lit LED
Unlit LED
• Source A preferred
Flashing LED
• Both sources of good quality and available
• Output is connected to Source A
• Source B preferred
• Both sources of good quality and available
• Output is connected to Source B
• Source A preferred
• Source A is of poor quality or unavailable
• Output is connected to Source B
• Source B preferred
• Source B is of poor quality or unavailable
• Output is connected to Source A
• Source A preferred
• Sources are of mixed levels of stability
Note: This event is
a rare occurrence.
• Output phases are powered by different sources
Note: “Available” LED will flash if phases of the source are of mixed levels of stability.
10
21-03-404-933363.indb 10
4/1/2021 1:09:36 PM
5. Using the Digital Display
5.1 Navigating Display Menus and Submenus (Measurement)
Press the MODE button to go to the next Display menu. Press the Enter button to go to the next
submenu (Amps, kW, Volts, Hz, PF). Press and hold MODE button for 2 seconds to switch to the
first Config menu (refer to Navigating Config Menus and Submenus section). Press and hold
both the MODE and Enter button for 2 seconds to show the IP address of the connected SNMP
card. The scrolling pattern of the menus is outlined below.
Source A
Phase Current (L1)
i.3.2
Ai
2.0.8
Ai
6.0
Ai
Volts (L1-L2)
Note: Since this is a 208V model, voltages
displayed are phase-to-phase voltages
(e.g., A1 in display indicates L1-L2 voltage).
Hz (L1-L2)
11
21-03-404-933363.indb 11
4/1/2021 1:09:37 PM
5. Using the Digital Display
Source A
Phase Current (L2)
i.3.2
A2
2.0.8
A2
6.0
A2
i.3.2
A3
2.0.8
A3
6.0
A3
Volts (L2-L3)
Hz (L2-L3)
Source A
Phase Current (L3)
Volts (L3-L1)
Hz (L3-L1)
12
21-03-404-933363.indb 12
4/1/2021 1:09:37 PM
5. Using the Digital Display
Source B
Phase Current (L1)
i.3.2
Volts (L1-L2)
2.0.8
Hz (L1-L2)
6.0
Source B
Phase Current (L2)
i.3.2
Volts (L2-L3)
2.0.8
Hz (L2-L3)
6.0
13
21-03-404-933363.indb 13
4/1/2021 1:09:38 PM
5. Using the Digital Display
Source B
Phase Current (L3)
i.3.2
Volts (L3-L1)
2.0.8
Hz (L3-L1)
6.0
Unbalanced Load Detect
Phase Imbalance %
i 0.0
Output Load Circuit
Circuit Current (L1-L2)
i 3.2
Ci
2.7 5
Ci
Kilowatts (L1-L2)
14
21-03-404-933363.indb 14
4/1/2021 1:09:38 PM
5. Using the Digital Display
Voltage (L1-L2)
Circuit Current (L1-L2) (Page 14)
208
Ci
Power Factor (L1-L2)
i.0 0
Ci
Output Load Circuit
Circuit Current (L2-L3)
i 3.2
C2
2.7 5
C2
208
C2
Kilowatts (L2-L3)
Voltage (L2-L3)
Power Factor (L2-L3)
i.0 0
C2
15
21-03-404-933363.indb 15
4/1/2021 1:09:39 PM
5. Using the Digital Display
Output Load Circuit
Circuit Current (L3-L1)
i 3.2
C3
2.7 5
C3
208
C3
Kilowatts (L3-L1)
Voltage (L3-L1)
Power Factor (L3-L1)
i.0 0
C3
Total Output Power
Kilowatts
Source A Phase Current (L1) (Page 11)
8.2 5
OP
Temperature
tC = Celsius; tF = Fahrenheit
25
16
21-03-404-933363.indb 16
4/1/2021 1:09:39 PM
5. Using the Digital Display
Fault Code Menu
The Fault Code Menu is only available when a breaker is tripped, causing the Breaker Trip LED to
illuminate. The display will jump to the Fault Code menu and auto scroll through the tripped
breakers (Only tripped breakers will be shown in the scroll sequence). Manual scrolling option is
still available, but Auto Scroll feature will remain active within the fault code menu while a fault
exists. If Auto Scroll is disabled, the display will still jump to the Fault Menu but you must manually
scroll through each tripped breaker individually. The number in the 3-digit display is defined as:
br1 = Output Breaker L1-L2; br2 = Output Breaker L2-L3; br3 = Output Breaker L3-L1
Breaker 1 Tripped
FC
Breaker 2 Tripped
FC
Breaker 3 Tripped
FC
IP Address Display
At any time you can press and hold both Mode and Enter buttons for 2 seconds to show the IP
address of the connected SNMP card. The 3 digit display will show “IP“. The 2 digit display to the right
of it will show one IP address digit at a time until it shows the entire IP address. Decimal points and
colons will be shown as hyphens. Note: This display supports IPv4 AND IPv6 addresses. The display
will automatically transition back to whatever mode it came from after displaying the IP address.
IP
I
17
21-03-404-933363.indb 17
4/1/2021 1:09:39 PM
5. Using the Digital Display
5.2 Navigating Config Menus and Submenus (Configuration)
While in any Display Menu, press and hold Mode button for 2 seconds to enter the first Config
menu. Press Mode button to cycle to the next Config menu. Press and hold Mode button for 2
seconds to switch to Display menus.
Temperature Unit Options
C–F
F
C–F
C
Hold Enter button for 2 seconds to switch
between options. The letter in the 2-digit
display indicates the selected unit, C for
Celsius and F for Fahrenheit.
2 Seconds
Preferred Source Selection
PSS
Hold Enter button for 2 seconds to switch
between Source A and Source B. The letter in
the 2-digit display indicates the selected source.
A
Note: If both sources are available, the unit will
transfer to the preferred source immediately once the
setting is changed.
2 Seconds
PSS
Auto Scroll Enable/Disable
When enabled, the Auto Scroll function cycles
through the output load circuit currents
(C1, C2, C3) menus in 4-second intervals.
“y” indicates the function is enabled; “n”
indicates that it is disabled. Pressing any
button interrupts the auto scroll function,
allowing the user to navigate between menu
options. If no button is pressed, there is a 10
second timeout and auto scroll will resume
from the current menu.
2 Seconds
18
21-03-404-933363.indb 18
4/1/2021 1:09:40 PM
5. Using the Digital Display
LED Brightness
Hold the Enter button for 2 seconds to scroll through each brightness option. The number in the
2-digit display is defined as: 1=25%; 2=50%; 3=75%; 4=100%.
Note: The default brightness option is 4 (100%).
4
2 Seconds
i
2 Seconds
2
2 Seconds
3
2 Seconds
LED Test
Hold Enter button for 2 seconds to start an
LED test. All LEDs will illuminate for 6 seconds.
Temperature Unit Options (Page 18)
2 Seconds
8.8.8.
88
19
21-03-404-933363.indb 19
4/1/2021 1:09:40 PM
6. Configuration and Operation
6.1 Automatic Transfer Switch
When the Source A and Source B inputs are both connected to power sources, the ATS operates
as an Automatic Transfer Switch, providing redundant input power for high availability applications.
The ATS will distribute power from the preferred input source under normal operating conditions
and switch to the other input source under abnormal conditions. The default preferred source is
Source A (Refer to the Navigating Config Menus and Submenus section for instructions on
changing the preferred source). The ATS will switch to the preferred source whenever it is “Good”
according to the ATS input voltage definitions (see section 6.1.2).
6.1.1 Preferred Configuration
The Automatic Transfer Switch function provides increased availability when the Source A and
Source B inputs of the ATS are connected to separate power sources. For maximum availability, it
is recommended, when using UPS Systems, that the UPS systems are matching with pure sine
wave output for the Source A and Source B input power sources. The automatic transfer switch
function will be compromised if the Source A and Source B inputs are connected to the same
utility power source.
Utility B
Utility A
Facility Circuit
Facility Circuit
Source B Power Source
Source A Power Source
Source A Input Cord
Source B Input Cord
208V~ / L1
- L2
5A OUTPUT
BREAKER
ATS
Equipment
Loads
Power Strip
20
21-03-404-933363.indb 20
4/1/2021 1:09:42 PM
6. Configuration and Operation
6.1.2 Automatic Transfer Switch Source Selection
The ATS will power up and supply output if at least one of the inputs is greater than the minimum
startup voltage. In normal operation, when both sources are of equal quality (“fair” or “good”), the
unit will select the preferred source according to the preferred source selection setting (Refer to the
Navigating Config Menus and Submenus section). If the currently selected source degrades to a
quality less than the currently unselected source, the unit will transfer to the better quality source.
If the currently unselected source improves in quality greater than the currently selected source,
the unit will transfer to the better quality source.
Note: In the event of a voltage loss on one of the 3-phase input conductors, the loads connected to the failed
phase conductor will transfer to the alternate source. The remaining load will follow and transfer to the alternate
source within 1 second. If both sources have mixed levels of stability in their phases, each load will select its own
input source on the basis of best available. If one of the sources has all 3 phases return to “good” quality, the
unit will then transfer all phases to that source.
Input Voltage Ranges
Nominal Voltage
208V
Minimum Startup Voltage
163V
Good Voltage Range
172-241V
Fair Voltage Range
144-171V
Bad Voltage Range
0-143V
6.1.3 Quick Test
After installing the ATS/power strip and connecting equipment, you
may test the Automatic Transfer Switch function by temporarily
disabling the preferred AC input (default is Source A). The ATS will
then switch from the preferred input to the alternate input. When
the preferred input resumes supplying power, the ATS will switch
back to the preferred input.
Note: The two inputs must be connected to separate sources of utility
power. The automatic transfer switch function will be compromised if the
two inputs are connected to the same power source. Do not perform a test
with equipment that must remain in productive operation. Any test
procedure must prepare for the contingency that the equipment may lose
power. Do not test the ATS by detaching power cords which are connected
to live power sources, as this eliminates the connection to ground and
places your equipment at risk.
Preferred Source (A) Active
Alternate Source (B) Active
21
21-03-404-933363.indb 21
4/1/2021 1:09:43 PM
7. Service
Your Tripp Lite product is covered by the warranty described in this manual. A variety of Extended
Warranty and On-Site Service Programs are also available from Tripp Lite. For more information on
service, visit www.tripplite.com/support. Before returning your product for service, follow these steps:
1. Review the installation and operation procedures in this manual to ensure that the service
problem does not originate from a misreading of the instructions.
2. If the problem continues, do not contact or return the product to the dealer. Instead, visit
www.tripplite.com/support.
3. If the problem requires service, visit www.tripplite.com/support and click the Request Return
(RMA) link. From here you can request a Returned Material Authorization (RMA) number, which is
required for service. This simple on-line form will ask for your unit’s model and serial numbers,
along with other general purchaser information. The RMA number, along with shipping instructions
will be emailed to you. Any damages (direct, indirect, special or consequential) to the product
incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered
under warranty. Products shipped to Tripp Lite or an authorized Tripp Lite service center must have
transportation charges prepaid. Mark the RMA number on the outside of the package. If the
product is within its warranty period, enclose a copy of your sales receipt. Return the product for
service using an insured carrier to the address given to you when you request the RMA.
8. Warranty and Product Registration
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects
in material and workmanship for a period of 3 years from the date of initial purchase. If the product should prove
defective in material or workmanship within that period, Seller will repair or replace the product, in its sole
discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all
shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 USA. Seller will pay
return shipping charges. Visit www.tripplite.com/support before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE,
ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET
FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES,
INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY
PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL
DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from
jurisdiction to jurisdiction).
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate
or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes
no representation or warranty as to the suitability or fitness of these devices for any specific application.
22
21-03-404-933363.indb 22
4/1/2021 1:09:43 PM
8. Warranty and Product Registration
PRODUCT REGISTRATION
Visit www.tripplite.com/warranty today to register your new Tripp Lite product. You'll be automatically entered into
a drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
FCC Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense. The user must
use shielded cables and connectors with this product. Any changes or modifications to this product not expressly
approved by the party responsible for compliance could void the user's authority to operate the equipment.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been
assigned a unique series number. The series number can be found on the product nameplate label, along with all
required approval markings and information. When requesting compliance information for this product, always
refer to the series number. The series number should not be confused with the marketing name or model number
of the product.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations,
when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to:
• Send old equipment for recycling on a one-for-one, like-for-like basis
(this varies depending on the country)
• Send the new equipment back for recycling when this ultimately becomes waste
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
23
21-03-404-933363.indb 23
21-03-404 93-3363_RevD
4/1/2021 1:09:43 PM
Manual del Propietario
PDU330AT6L15, PDU330AT6L21
(Número de Serie: AG-00D5)
PDU Trifásico Monitoreable de 1U para Rack
con Switch de Transferencia Automática (ATS)
PDU3VD351
(Número de Serie: AG-00C2)
PDU3V20D354, PDU3V20D354A, PDU3V20D354B
(Número de Serie: AG-013C)
Barra de Contactos Trifásica Vertical
1. Instrucciones de Seguridad 25
Importantes
2. Instalación
26
5. Uso de la Pantalla Digital
5.2 Menúes de Configuración
41
de Navegación y Sub Menúes
2.1 Instalación del ATS
26
2.2 Instalación de la Barra
de Contactos
27
2.3 Conexión de la Barra
de Contactos al ATS
27
6.1 Switch de Transferencia
Automática
2.4 Conexión del ATS
28
2.5 Conexión a Red del ATS
28
7. Servicio
8. Garantía
English
Français
3. Características
4. Pantalla Digital
34
5.1 Menúes de Pantalla
34
de Navegación y Sub Menúes
6. Configuración y Operación
29
31
43
43
45
46
1
47
1111 W. 35th Street, Chicago, IL 60609 EE UU • www.tripplite.com/support
Copyright © 2015 Tripp Lite. Todos los derechos reservados.
24
21-03-404-933363.indb 24
4/1/2021 1:09:43 PM
1. Instrucciones de Seguridad Importantes
CONSERVE ESTAS INSTRUCCIONES
Este manual contiene instrucciones y advertencias que deben seguirse durante la
instalación, operación y almacenamiento de este producto. La omisión en la
observancia de estas instrucciones y advertencias puede afectar la garantía
del producto.
PRECAUCION Este aparato no se destina para utilizarse por personas (incluyendo niños), cuyas
capacidades fisicas, sensoriales o mentales sean diferentes o estén reducidas, o carezcan de experiencia o
conocimiento, a menos que dichas personas reciban una supervisión o capacitación para el funcionamiento
del aparato por una persona responsable de su seguridad.
Los ninos deben de supervisarse para asegurar que no empleen el aparato como juguete.
Nunca utilize el aparato si el cable y la clavija están dañados; si no funciona correctamente o si se ha caido
o dañado, llévelo a un centro de servicio autorizado para que lo examinen y lo reparen.
Si el cordon de alimentación es dañado, éste debe sustituirse por el fabricante, por su agente de servicio
autorizado o por personal calificado con el fin de evitar un peligro.
• La Barra de Contactos proporciona la conveniencia de múltiples tomacorrientes, pero NO proporciona
protección contra sobretensiones o ruido en la línea para los equipos conectados.
• No exceda las siguientes especificaciones del equipo:
• La carga plena máxima balanceada es de 13.9A por banco cuando se alimenta por un ATS (Switch de
Transferencia Automática) trifásico con una entrada especificada de 24A.
• La carga plena máxima balanceada es de 20A por banco cuando se alimenta por un ATS (Switch de
Transferencia Automática) trifásico con una entrada especificada de 35A.
• El Switch de Transferencia Automática y la Barra de Contactos están diseñados solo para uso en
interiores en un entorno controlado lejos de humedad excesiva, temperaturas extremas, contaminantes
conductivos, polvo o luz del sol directa.
• Mantiene la temperatura ambiente interior entre 32°F y 104°F (0°C y 40°C).
• El Switch de Transferencia Automática y la Barra de Contactos deben ser instalados solamente por un
técnico calificado.
• No intente instalar el Switch de Transferencia Automática o la Barra de Contactos en una superficie
inestable o insegura.
• Instale de acuerdo con los estándares del Código Eléctrico Nacional (NEC). Asegúrese de usar para la
instalación la protección adecuada contra sobrecorriente, de acuerdo con la especificación de la clavija o
del equipo.
• Conecte el Switch de Transferencia Automática a un tomacorriente que esté de acuerdo a los códigos
locales de construcción y que esté correctamente protegido contra corrientes excesivas, cortocircuitos y
fallas de conexión a tierra.
• Los tomacorrientes eléctricos que suministran energía al equipo deben instalarse próximos al equipo y
ser fácilmente accesibles.
• No conecte el Switch de Transferencia Automática a un toma corriente que no esté a tierra o cables de
extensión o adaptadores que eliminen la conexión a tierra.
• Asegúrese de proporcionar un dispositivo local de desconexión, que sea fácilmente accesible, en
cualquier modelo que esté instalado permanentemente sin una clavija.
• Nunca intente instalar equipos eléctricos durante una tormenta eléctrica.
• El equipo individual conectado a la Barra de Contactos no debe consumir más corriente que la de la
especificación de cada tomacorriente individual.
• La carga total conectada a la Barra de Contactos no debe exceder la capacidad de carga máxima del
Switch de Transferencia Automática.
• No intente modificar las clavijas o cables de alimentación del Switch de Transferencia Automática o de la
Barra de Contactos.
• No perfore ni intente abrir ninguna parte del gabinete del Switch de Transferencia Automática o de la
Barra de Contactos. No tiene partes a las que el usuario pueda dar servicio.
• No intente usar el Switch de Transferencia Automática o la Barra de Contactos si se daña cualquier
parte.
• No se recomienda el uso de este equipo en aplicaciones de soporte de vida en donde la falla de este
equipo pueda consecuentemente causar la falla del equipo de soporte de vida o afectar
significativamente su seguridad o efectividad. No use este equipo en presencia de una mezcla inflamable
de anestésicos con aire, oxígeno u óxido nitroso.
25
21-03-404-933363.indb 25
4/1/2021 1:09:43 PM
2. Instalación
2.1 instalación del Switch de Transferencia Automática (ATS)
Importante: El ATS debe instalarse en los rieles del rack en el espacio U más bajo
disponible (altura < 36 pulg./1 m).
instale su equipo es un rack o gabinete de rack de 4 postes. Antes de la instalación, el usuario
debe determinar la adecuación de los accesorios y procedimientos. Si los accesorios y
procedimientos no son adecuados para su aplicación, póngase en contacto con el fabricante de su
rack o gabinete. Los procedimientos descritos en este manual son para tipos comunes de racks y
gabinetes y pueden no ser apropiados para todas las aplicaciones.
Nota: Cada conjunto de riel lateral de broche consta de un soporte de instalación de gabinete y un riel de canal
interno. Para facilidad de instalación, los rieles de canal internos vienen preinstalados en la unidad del ATS.
1 Alinee las pestañas del soporte posterior
con lo orificios cuadrados de instalación
del gabinete y empuje los ganchos
metálicos a través de los orificios de
instalación 1A . Empuje entonces el
soporte posterior hacia el soporte del
gabinete para que las pestañas azules
abrochen el soporte en su sitio. 1B .
Después alinee las pestañas del soporte
frontal con los orificios cuadrados de
instalación. Oprima los ganchos metálicos
del soporte delantero a través de los
orificios de instalación y empuje el
soporte delantero hacia el soporte del
gabinete para que las pestañas azules
abrochen al soporte en su sitio.
Asegúrese de instalar el soporte de
instalación en el espacio U más bajo.
1A
1B
2 Repita el paso uno para el segundo
soporte de instalación en el lado opuesto
del gabinete.
3 Una vez fijos ambos soportes de
instalación en el gabinete, asegure los
soportes posteriores usando los tornillos
M5X10L incluidos.
3
4 Alinee los rieles de canal internos
acoplados al ATS con los soportes de
instalación. Deslice entonces la unidad
en el conjunto de riel. Usando un
desatornillador, fije los tornillos de
instalados en el panel del ATS al
gabinete.
4
26
21-03-404-933363.indb 26
4/1/2021 1:09:44 PM
2. Instalación
2.2 Instalación de la Barra de Contactos
Nota: Para instalación sin herramienta, los botones
de instalación vienen preinstalados a la barra de
contactos. Un segundo juego de orificios de
instalación por botón en la barra de contactos
permite la ubicación alterna en el rack.
Coloque la barra de contactos como desee
dentro del gabinete, alinee los botones con las
ranuras de instalación del rack y deslice la
barra de contactos hacia abajo a su posición.
Su modelo puede variar ligeramente del de la imagen.
2.3 Conexión de la Barra de Contactos al ATS
La barra de contactos tiene un cable de 7
conductores con una clavija de 8 posiciones.
La clavija se instala directamente al
receptáculo coincidente del ATS en la parte
posterior de la unidad.
Su modelo puede variar ligeramente del de la imagen.
27
21-03-404-933363.indb 27
4/1/2021 1:09:45 PM
2. Instalación
2.4 Conexión del ATS
2.4.1 Conexión de las Clavijas de
Entrada del ATS
Nota: El ATS viene equipado con dos alimentaciones
trifásicas de CA: Fuente A y Fuente B. Fuente A es la
fuente preferida (primaria) predeterminada. Para
instrucciones sobre el cambio de la fuente preferida,
consulte la sección Menúes de Configuración de
Navegación y Sub Menúes. Las instrucciones de
conexión siguientes asumen que la Fuente A es la
fuente preferida.
A
B
Conecte la clavija de alimentación de la
Fuente A A a una fuente de alimentación
trifásica de CA preferida. Bajo condiciones de
operación normales, el ATS distribuirá la
alimentación de CA desde la fuente de entrada
de la Fuente A. Conecte la clavija de
alimentación de la Fuente B B a una fuente
alternativa de energía de CA con conexión a
tierra. No enchufe la entrada de la Fuente B
en la misma fuente de alimentación que la
entrada de la Fuente A. El ATS distribuirá la
alimentación de CA desde la entrada de la
Fuente B solo si la entrada de la Fuente A no
está disponible o es inestable.
2.4.2 Conexión del Equipo
a la Barra de Contactos
No exceda el valor nominal de carga de la barra
de contactos. La corriente eléctrica total
utilizada por cada fase de la barra de contactos
aparecerá en el medidor digital en amperes.
2.5 Conexión a Red del ATS
Su ATS puede recibir la asignación de su dirección IP mediante los métodos de direccionamiento
del servidor DHCP (dinámico) o estático (manual). Si no está seguro de cuál método usar, póngase
en contacto con su administrador de red para asistencia antes de continuar el proceso de
configuración.
Nota: La dirección MAC (una serie de 12 dígitos en el formato: 000667xxxxxx) está impresa en una etiqueta y
pegada al gabinete del ATS. Para la asignación estática de la dirección IP, use el cable de configuración
DB9(730866) incluido con el ATS.
El ATS proporciona monitoreo remoto y más mediante un navegador de red, telnet y sistemas de
administración de red basados en SNMP. Para obtener más información sobre la configuración y
operación del ATS mediante la interfaz del navegador de red PowerAlert, consulte la Guía del
Usuario de SNMPWEBCARD visitando www.tripplite.com/support y escribiendo SNMPWEBCARD en
el campo de búsqueda.
28
21-03-404-933363.indb 28
4/1/2021 1:09:45 PM
3. Características
Barra de Contactos
(PDU3VD351, PDU3V20D354, PDU3V20D354A, PDU3V20D354B)
2 11
1
ATS Switch de Transferencia Automática (PDU330AT6L15/PDU330AT6L21)
4
11
5
10
3
12
8
7
9
6
1 Tomacorrientes de la Barra de Contactos: Estos tomacorrientes IEC C13 y C19
monofásicos reciben energía de las conexiones de alimentación trifásica de la Fuente A o la
Fuente B del ATS. Estos tomacorrientes no son controlables.
2 Cable de Alimentación de la Barra de Contactos: El cable de
7 conductores tiene un conector de 8 posiciones que se acopla
directamente al ATS.
29
21-03-404-933363.indb 29
4/1/2021 1:09:48 PM
3. Características
3 Entrada de la Fuente A y la Fuente B del ATS: Los cables
están acoplados permanentemente al ATS y tienen clavijas
L15-30P o L21-30P.
4 Pantalla Digital: Muestra el estado de la fuente, valores
medidos, modos de pantalla y otra información. Consulte la
sección de Pantalla Digital para explicación detallada de los
indicadores y pantallas.
L15-30P
5 Botón de Restaurar SNMP: Para reiniciar la tarjeta de red
del ATS, oprima por 3 segundos el botón de restaurar.
Reiniciar la tarjeta de red no borrará los parámetros de red o
interrumpirá la alimentación de CA. El botón de restauración
está hundido. Use un clip para papel u otro objeto adecuado
para oprimirlo.
L21-30P
6
A
B
Interfaz de Red: Use el conector RJ-45 para conectar el ATS a la red con
un cable patch Ethernet estándar. El LED de Estado A y el LED de Liga B
indican condiciones de operación, como se muestra en la siguiente tabla.
Estos puertos no son compatibles con aplicaciones de PoE (Energía sobre
la Ethernet).
Condiciones de operación de la red
A Color del LED de Estado
B Color del LED de Liga
Apagado
Tarjeta no inicializada
Apagado
Sin conexión de red
Verde permanente
Tarjeta inicializada y
operativa
Destellando en
ámbar
Conexión de red de 100
Mbps
Destellando en
ámbar
Error - Tarjeta no inicializada
Destellando en verde Conexión de red de 10 Mbps
7 Puerto de Configuración DB9: Use este puerto para proporcionar una conexión directa de
terminal a una computadora con un programa de emulación de terminal. Con el ATS se
incluye un cable serial. Si necesita ordenar un cable de repuesto, comuníquese con el
Soporte al cliente de Tripp Lite al www.tripplite.com/support.
8 Tomacorriente de Conveniencia IEC-320-C13: Este tomacorriente recibe energía desde la
fase L1-L2, pero no es controlable. Contribuye a la carga total de L1-L2.
9 Breakers del Tomacorriente de Conveniencia IEC-320-C13: Existen dos interruptores
térmicos automáticos para proteger cada lado del tomacorriente de conveniencia.
10 Breaker: Cada carga de salida de fase única tiene su propio interruptor magnético
automático. Si la carga del equipo conectado excede la Especificación Máxima de Carga para
esa fase, el breaker se disparará. Desconecte el equipo excesivo antes de restaurar el(los)
breaker(es).
11 Tornillo de Conexión a Tierra: Úselo para conectar cualquier equipo que requiera una
conexión de tierra a chasís.
12 Receptáculo de Concordancia de ATS: Este receptáculo acepta solamente el conector de
8 posiciones en el cable de alimentación de la barra de contactos.
30
21-03-404-933363.indb 30
4/1/2021 1:09:49 PM
4. Pantalla Digital
3
1
2
5
4
6
7
8
1 LEDs de Estado de la Fuente: Los patrones de los LEDs encendidos indican qué fuente es
preferida, qué fuente está disponible para uso y qué fuente se está usando actualmente.
Consulte la sección de Indicadores LED del Estado de la Fuente para una explicación de
los patrones de los LEDs.
2 LED de Disparo del Breaker: Encendido cuando se ha disparado un breaker.
3 Pantalla de 3 Dígitos: Muestra los valores medidos o calculados Amperaje, Kilowatts, Voltaje,
Porcentaje de Desbalanceo de Potencia, Frecuencia, Factor de Potencia y Temperatura.
4 Botón Enter: Cuando se ha seleccionado un menú usando el Botón de Modo, el Botón Enter
se desplaza a través de los Sub Menúes dentro de cada categoría. Los Sub Menúes son
mostrados por los LEDs indicadores.
Nota: Oprimir simultáneamente los botones Enter y Mode por 2 segundos muestra la dirección IP.
5 LEDs Indicadores: El LED encendido indica qué valor se está mostrando en la pantalla de
3 dígitos.
Amperes (A): La corriente de entrada en la entrada de la Fuente seleccionada (A# o b#) o
en el circuito de Carga de Salida (C#) se muestra en Amperes.
Potencia (kW): La Potencia de Salida para el Circuito Seleccionado de Carga de Salida (C#)
o la Potencia Total de Salida (OP) se muestra en kW.
Voltaje (V): El voltaje de fase a fase de alimentación de la Fuente A o B (A# o b#) o del
Circuito de la Carga de Salida (C#) se muestra en Volts.
Frecuencia (Hz): La frecuencia de la Entrada de la Fuente A o B se muestra en Hz.
Factor de Potencia (PF): El factor de Potencia de la Carga de Salida se muestra como
decimal (de 0 a 1.00).
31
21-03-404-933363.indb 31
4/1/2021 1:09:49 PM
4. Pantalla Digital
6 Pantalla de 2 Dígitos: Esta pantalla indica qué modo de pantalla está seleccionado:
Fase de Entrada de Fuente (A# o b#), % Desbalanceo (Ub), Circuitos de Salida (C#),
Potencia Total de Salida (OP), Temperatura (tC o tF), o Código de Falla (FC).
Fases de Fuente A (A#): Muestra las mediciones en pantalla para Fuente A. Incluyen
corriente de Fase (A), Voltaje (V) y Frecuencia (Hz).
Fases de Fuente B (B#): Muestra las mediciones en pantalla para Fuente B. Incluyen
corriente de Fase (B), Voltaje (V) y Frecuencia (Hz).
% Desbalanceo (Ub): La pantalla muestra la desviación en porcentaje de desbalanceo de
carga del valor promedio medido. Se muestra el porcentaje para la fase con la mayor
desviación.
Circuitos de Salida (C#): Muestra mediciones para el Circuito de Salida. Incluyen
Corriente (A), Kilowatts (kW), Voltaje (V) y Factor de Potencia (PF).
Potencia Total de Salida (OP): Muestra la potencia total en todos los circuitos de salida.
Temperatura (t): La temperatura ambiente se muestra al seleccionar la opción. Se muestra
la temperatura en Celsius en forma predeterminada, pero puede cambiarse a Fahrenheit.
Código de Falla (FC): El Código de Falla se mostrará solamente si se ha disparado el
breaker.
7 Botón de Modo: Usando este botón, desplácese entre los menúes de Pantalla y
Configuración. La elección de menú de pantalla se muestra en la pantalla de 2 dígitos.
La elección de menú de configuración se muestra en la pantalla de 3 dígitos.
8 Botón de Restaurar SNMP: Para reiniciar la tarjeta de red del ATS, oprima por tres
segundos el botón de restaurar. Reiniciar la tarjeta de red no borrará los parámetros de red o
interrumpirá la alimentación de CA. El botón de restauración está hundido. Use un clip para
papel u otro objeto adecuado para ejecutar una restauración.
32
21-03-404-933363.indb 32
4/1/2021 1:09:49 PM
4. Pantalla Digital
Indicadores LED del Estado de Fuente
Patrón de LED
Descripción
LED Encendido
LED Apagado
• Fuente A preferida
LED Destellando
• Ambas fuentes de buena calidad y disponibles.
• La salida está conectada a la Fuente A
• Fuente B preferida
• Ambas fuentes de buena calidad y disponibles.
• La salida está conectada a la Fuente B
• Fuente A preferida
• La Fuente A es de calidad deficiente o no está disponible
• La salida está conectada a la Fuente B
• Fuente B preferida
• La Fuente B es de calidad deficiente o no está disponible
• La salida está conectada a la Fuente A
• Fuente A preferida
• Las fuente son de niveles de estabilidad mezclados
Nota: Este evento
es de ocurrencia
poco común.
• Las fases de salida son alimentadas por fuentes diferentes
Nota: El LED “Available” [Disponible] destellará si las fases de la fuente son de niveles de estabilidad mezclados.
33
21-03-404-933363.indb 33
4/1/2021 1:09:49 PM
5. Uso de la Pantalla Digital
5.1 Menúes de Pantalla de Navegación y Sub Menúes
(Medición)
Oprima el botón MODE para ir al siguiente menú de pantalla. Oprima el botón Enter para ir al
siguiente sub menú (Amperes, kW, Volts, Hz, PF). Oprima y sostenga por 2 segundos el botón
MODE para cambiar al primer menú de Configuración (Consulte la sección Menúes de
Configuración de Navegación y Sub Menúes). Oprima y sostenga los botones MODE y Enter
durante 2 segundos para mostrar la dirección IP de la tarjeta SNMP conectada. El patrón de
cambio de los menúes se describe a continuación.
Fuente A
Corriente de Fase (L1)
i.3.2
Ai
2.0.8
Ai
6.0
Ai
Volts (L1-L2)
Nota: Ya que este es un modelo de 208V, los
voltajes mostrados son voltajes de fase a fase
(e.g., A1 en pantalla indica voltaje entre
L1-L2).
Hz (L1-L2)
34
21-03-404-933363.indb 34
4/1/2021 1:09:50 PM
5. Uso de la Pantalla Digital
Fuente A
Corriente de Fase (L2)
i.3.2
A2
2.0.8
A2
6.0
A2
Volts (L2-L3)
Hz (L2-L3)
Fuente A
Corriente de Fase (L3)
i.3.2
A3
2.0.8
A3
6.0
A3
Volts (L3-L1)
Hz (L3-L1)
35
21-03-404-933363.indb 35
4/1/2021 1:09:51 PM
5. Uso de la Pantalla Digital
Fuente B
Corriente de Fase (L1)
i.3.2
Volts (L1-L2)
2.0.8
Hz (L1-L2)
6.0
Fuente B
Corriente de Fase (L2)
i.3.2
Volts (L2-L3)
2.0.8
Hz (L2-L3)
6.0
36
21-03-404-933363.indb 36
4/1/2021 1:09:52 PM
5. Uso de la Pantalla Digital
Fuente B
Corriente de Fase (L3)
i.3.2
Volts (L3-L1)
2.0.8
Hz (L3-L1)
6.0
Detección de Desbalanceo de Carga
Desbalanceo de Fase %
i 0.0
Circuito de Carga de Salida
Corriente de Circuito (L1-L2)
i 3.2
Ci
2.7 5
Ci
Kilowatts (L1-L2)
37
21-03-404-933363.indb 37
4/1/2021 1:09:54 PM
5. Uso de la Pantalla Digital
Voltaje (L1-L2)
Corriente de Circuito (L1-L2) (Pág. 37)
208
Ci
Factor de Potencia (L1-L2)
i.0 0
Ci
Circuito de Carga de Salida
Corriente de Circuito (L2-L3)
i 3.2
C2
2.7 5
C2
208
C2
Kilowatts (L2-L3)
Voltaje (L2-L3)
Factor de Potencia (L2-L3)
i.0 0
C2
38
21-03-404-933363.indb 38
4/1/2021 1:09:55 PM
5. Uso de la Pantalla Digital
Circuito de Carga de Salida
Corriente de Circuito (L3-L1)
i 3.2
C3
2.7 5
C3
208
C3
Kilowatts (L3-L1)
Voltaje (L3-L1)
Factor de Potencia (L3-L1)
i.0 0
C3
Potencia Total de Salida
Fuente A Corriente de Fase (L1) (Pág. 34)
Kilowatts
8.2 5
OP
Temperatura
tC = Celsius; tF = Fahrenheit
25
39
21-03-404-933363.indb 39
4/1/2021 1:09:56 PM
5. Uso de la Pantalla Digital
Menú de Código de Falla
El Menú de Código de Falla está disponible solamente cuando se dispara un breaker, causando
que se encienda el LED de disparo del breaker. La pantalla saltará al menú de código de falla y
cambiará automáticamente a través de los breakers disparados (Solo se mostrarán breakers
disparados en la secuencia de cambio de menú). La opción de desplazamiento manual de menú
aún está disponible, pero la característica de desplazamiento automático de menú permanecerá
activa dentro del menú de código de falla mientras exista una falla. Si el desplazamiento
automático de menú está desactivado, la pantalla cambiará aún al menú de falla, pero usted debe
desplazarse manualmente a través de cada breaker disparado en forma individual. El número en la
pantalla de 3 dígitos se define como:
br1 = Breaker de Salida L1-L2; br2 = Breaker de Salida L2-L3; br3 = Breaker de Salida L3-L1
Breaker 1 Disparado
FC
Breaker 2 Disparado
FC
Breaker 3 Disparado
FC
Pantalla de Dirección IP
En cualquier momento puede oprimir y sostener los botones de Mode y Enter durante 2 segundos
para mostrar la dirección IP de la tarjeta SNMP conectada. La pantalla de 3 dígitos mostrará “IP“.
La pantalla de 2 dígitos a la derecha mostrará un dígito de la dirección IP a la vez hasta mostrar
toda la dirección IP. Los puntos decimales y comas se mostrarán como guiones. Nota: Esta
pantalla soporta direcciones IPv4 e IPv6. Después de mostrar la dirección IP, la pantalla regresará
automáticamente a cualquier modo que en el que estuviera antes.
IP
I
40
21-03-404-933363.indb 40
4/1/2021 1:09:57 PM
5. Uso de la Pantalla Digital
5.2 Menúes de Configuración de Navegación y Sub Menúes
(Configuración)
Estando en cualquier menú de pantalla, oprima y sostenga el botón de Modo por 2 segundos para
ingresar al primer menú de configuración. Para cambiar al siguiente menú de configuración, oprima
el botón de Modo. Oprima y sostenga por 2 segundos el botón de Modo para cambiar a los
menúes de Pantalla.
Opciones de Temperatura de Unidad
C–F
F
C–F
C
Sostenga el botón Enter por 2 segundos para
cambiar entre opciones. La letra en la pantalla
de 2 dígitos indica la unidad seleccionada, C
para Celsius y F para Fahrenheit.
2 Segundos
Selección de Fuente Preferida
PSS
Sostenga el botón Enter por 2 segundos para
cambiar entre la Fuente A y la Fuente B. La
letra en la pantalla de 2 dígitos indica la
fuente seleccionada.
A
Nota: Si ambas fuentes están disponibles, la unidad
se transferirá inmediatamente a la fuente preferida,
una vez cambiado el parámetro.
2 Segundos
PSS
Activar/Desactivar Desplazamiento Automático de Pantalla
Cuando está activada, la función de
desplazamiento automático de menú cambia a
través de los menúes de corrientes del circuito
de carga de salida (C1, C2, C3) en intervalos
de 4 segundos. “y” indica que la función está
activada; “n” indica que está desactivada.
Oprimir cualquier botón interrumpe la función
de desplazamiento automático del menú,
permitiendo al usuario navegar entre las
opciones del menú. Si ningún botón se
oprime, hay un lapso de vencimiento de 10
segundos y se reiniciará el desplazamiento
automático de los menúes desde el menú
actual.
2 Segundos
41
21-03-404-933363.indb 41
4/1/2021 1:09:58 PM
5. Uso de la Pantalla Digital
Brillo del LED
Sostenga por 2 segundos el botón Enter para desplazarse a través de cada opción de brillo. El
número en la pantalla de 2 dígitos se define como: 1=25%; 2=50%; 3=75%; 4=100%.
Nota: La opción de brillo predeterminado es 4 (100%).
4
2 Segundos
i
2 Segundos
2
2 Segundos
3
2 Segundos
Prueba de los LEDs
Sostenga por 2 segundos el botón Enter para
iniciar una prueba de los LEDs. Todos los LEDs
se iluminarán por 6 segundos.
Opciones de Temperatura de Unidad
(Pág. 41)
2 Segundos
8.8.8.
88
42
21-03-404-933363.indb 42
4/1/2021 1:09:59 PM
6. Configuración y Operación
6.1 Switch de Transferencia Automática
Cuando las entradas de la Fuente A y de la Fuente B están conectadas a las fuentes de energía, el
ATS opera como un Switch de Transferencia Automática, proporcionando energía redundante de
entrada para aplicaciones de alta disponibilidad. Bajo condiciones de operación normales, el ATS
distribuirá energía desde la fuente de entrada preferida y cambiando a la otra fuente de entrada
bajo condiciones anormales. La fuente preferida predeterminada es la Fuente A (Para instrucciones
sobre el cambio de la fuente preferida, consulte la sección Menúes de Configuración de
Navegación y Sub Menúes). El ATS cambiará a la fuente preferida cuando esté "Buena" según
las definiciones de voltaje de entrada del ATS (vea la sección 6.1.2).
6.1.1 Configuración preferida
La función de Switch de Transferencia Automática proporciona mayor disponibilidad cuando las
entradas de la Fuente A y de la Fuente B del ATS están conectados a fuentes de alimentación
separadas. Para disponibilidad máxima, es recomendable, al usar Sistemas UPS, que los Sistemas
UPS coincidan con la salida de onda sinusoidal pura para las fuentes de alimentación de la Fuente
A y la Fuente B. La función del Switch de Transferencia Automática se comprometerá si las entradas
de la Fuente A y de la Fuente B están conectadas a la misma fuente de energía de la red pública.
Red pública B
Red pública A
Circuito de la instalación
Fuente B fuente de
alimentación
Cable de la entrada Fuente
Fuente A fuente de
alimentación
Cable de la entrada Fuente A
208V~ / L1
- L2
5A OUTPUT
BREAKER
ATS
Cargas de
los equipos
Barra de
contactos
43
21-03-404-933363.indb 43
4/1/2021 1:10:01 PM
6. Configuración y Operación
6.1.2 Selección de la fuente del Switch de Transferencia Automática
El ATS se encenderá y proporcionará salida si al menos una de las entradas es mayor que el
voltaje mínimo de arranque. En operación normal, cuando ambas fuentes sean de calidad igual
(“aceptable” o “buena”), la unidad seleccionará la fuente preferida de acuerdo con la configuración
de selección de fuente preferida (Consulte la sección Menúes de Configuración de Navegación
y Sub Menúes). Si la fuente actualmente seleccionada se degrada a una calidad inferior que la
fuente actualmente no seleccionada, la unidad se transferirá a la fuente de mejor calidad. Si la
fuente actualmente no seleccionada mejora a una calidad mayor que la fuente actualmente
seleccionada, la unidad se transferirá a la fuente de mejor calidad.
Nota: En caso de una pérdida de voltaje de los conductores de entrada trifásica, las cargas
conectadas al conector de la fase con falla se transferirán a la fuente alternativa. La carga
remanente seguirá y se transferirá a la fuente alternativa en un plazo de 1 segundo. Si ambas
fuentes tienen niveles mezclados de estabilidad en sus fases, cada carga seleccionará su propia
fuente de alimentación con base en la mejor disponible. Si una de las fuentes tiene las tres fases
de regreso a “buena” calidad, la unidad transferirá entonces todas las fases a esa fuente.
Rangos de Voltaje de Entrada
208V
Voltaje Nominal
163V
Voltaje Mínimo de Arranque
Rango de Voltaje Bueno
172-241V
Rango de Voltaje Aceptable
144-171V
0-143V
Rango de Voltaje Malo
6.1.3 Prueba Rápida
Después de instalar el ATS y conectar el equipo, puede probar la
función del Switch de Transferencia Automática desactivando la
entrada de CA preferida (la predeterminada es la Fuente A). El
ATS cambiará entonces de la entrada preferida a la entrada
alterna. Cuando la fuente preferida retome el suministro de
energía, el ATS cambiará nuevamente a la entrada preferida.
Nota: Las dos entradas deben conectarse a fuentes separadas de energía
de la red pública. La función del Switch de Transferencia Automática se
comprometerá si las dos entradas están conectadas a la misma fuente de
energía. No realice una prueba con equipo que deba permanecer en
operación productiva. Cualquier procedimiento de prueba debe prevenir y
prepararse para la contingencia de que el equipo pueda perder su energía.
No pruebe el ATS desconectando los cables de alimentación que están
conectados a las fuentes de energía activas, ya que esto elimina la
conexión a tierra y pone su equipo en riesgo.
Fuente Preferida (A) Activa
Fuente Alterna (B) Activa
44
21-03-404-933363.indb 44
4/1/2021 1:10:01 PM
7. Servicio
Su producto Tripp Lite está cubierto por la garantía descrita en este manual. Está disponible una
variedad de Programas de Garantía Extendida y Servicio En el Sitio por parte de Tripp Lite. Para
información adicional acerca del servicio, visite www.tripplite.com/support. Antes de regresar su
producto para servicio, siga estos pasos:
1. Revise los procedimientos de instalación y operación en este manual para asegurar que el
problema de servicio no se origina por una mala lectura de las instrucciones.
2. Si el problema persiste, no se ponga en contacto ni regrese el producto al distribuidor. En vez de
ello, visite www.tripplite.com/support.
3. Si el problema requiere de servicio, visite www.tripplite.com/support y haga click en la liga de
Autorización de Devolución de Mercancía (RMA). Desde aquí usted puede solicitar un número
de Autorización de Devolución de Mercancía (RMA) que se requiere para el servicio. Esta
sencilla forma en línea solicitará los números de modelo y serie de su unidad junto con otra
información general del comprador. El número de RMA junto con las instrucciones de embarque
le serán enviadas por correo electrónico. Cualquier daño (directo, indirecto, especial o
consecuencial) al producto incurrido durante el embarque a Tripp Lite o un Centro de Servicio
Autorizado de Tripp Lite no está cubierto bajo la garantía. Los productos embarcados a Tripp Lite
o un Centro de Servicio Autorizado de Tripp Lite deben tener cargos de transporte prepagados.
Marque el número de RMA en el exterior del empaque. Si el producto está dentro del período
de garantía, adjunte una copia de su recibo de venta. Regrese el producto para servicio usando
un transportista asegurado a la dirección proporcionada a usted cuando solicitó la RMA.
45
21-03-404-933363.indb 45
4/1/2021 1:10:01 PM
8. Garantía
GARANTÍA LIMITADA
El vendedor garantiza este producto, si se usa de acuerdo con todas las instrucciones aplicables, de que está
libre de defectos en material y mano de obra por un período de 3 años a partir de la fecha de compra inicial. Si
el producto resulta defectuoso en material o mano de obra dentro de ese período, el vendedor reparará o
reemplazará el producto a su entera discreción. El servicio bajo esta garantía sólo puede obtenerse enviando o
embarcando el producto (con todos los cargos de envío o embarque prepagados) a: Tripp Lite, 1111 W. 35th
Street, Chicago, IL 60609 EE UU. El vendedor reembolsará los cargos de embarque. Antes de devolver cualquier
equipo para reparación, visite www.tripplite.com/support.
ESTA GARANTÍA NO APLICA AL DESGASTE NORMAL O A DAÑOS RESULTANTES DE ACCIDENTES, MAL USO,
ABUSO O NEGLIGENCIA. EL VENDEDOR NO OTORGA GARANTÍAS EXPRESAS DISTINTAS DE LA ESTIPULADA AQUÍ.
EXCEPTO A LA EXTENSIÓN PROHIBIDA POR LA LEY APLICABLE, TODAS LAS GARANTÍAS IMPLÍCITAS, INCLUYENDO
TODAS LAS GARANTÍAS DE COMERCIALIZACIÓN O IDONEIDAD, ESTÁN LIMITADAS EN DURACIÓN AL PERÍODO DE
GARANTÍA ESTABLECIDO; Y ESTA GARANTÍA EXCLUYE EXPRESAMENTE TODOS LOS DAÑOS INCIDENTALES Y
CONSECUENCIALES. (Algunos estados no permiten limitaciones en cuanto dura una garantía y algunos estados
no permiten la exclusión de limitación de daños incidentales o consecuenciales, de modo que las limitaciones
anteriores pueden no aplicar para usted. Esta garantía le otorga derechos legales específicos y usted puede
tener otros derechos que pueden variar de una jurisdicción a otra).
ADVERTENCIA: Antes de usarlo, cada usuario debe debe tener cuidado al determinar si este dispositivo es
adecuado o seguro para el uso previsto. Ya que las aplicaciones individuales están sujetas a gran variación, el
fabricante no garantiza la adecuación de estos dispositivos para alguna aplicación específica.
Números de Identificación de Conformidad Regulatoria
Para el propósito de certificaciones e identificación de conformidad regulatoria, su producto Tripp Lite ha recibido
un número de serie único. El número de serie puede encontrarse en la etiqueta de placa de identificación, junto
con todas las marcas e información requeridas de aprobación. Al solicitar información de conformidad para este
producto, refiérase siempre al número de serie. El número de serie no debe confundirse con el nombre de la
marca o el número de comercialización del producto.
Información de Cumplimiento con WEEE por los Clientes y Recicladores de Tripp Lite (Unión Europea)
Bajo la Directiva de Desechos de Equipos Eléctricos y Electrónicos (WEEE) [Waste Electrical and
Electronic Equipment] y regulaciones aplicables, cuando los clientes adquieren un nuevo equipo
eléctrico y electrónico de Tripp Lite están obligados a:
• Envíe el equipo viejo a reciclado en una base de uno por uno, equivalente por equivalente
(esto varía de un país a otro)
• Regrese el equipo nuevo para reciclado una vez que finalmente sea un desecho
Tripp Lite tiene una política de mejora continua. Las especificaciones están sujetas a cambio sin previo aviso.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
46
21-03-404-933363.indb 46
21-03-404 93-3363_RevD
4/1/2021 1:10:01 PM
Manuel de l'utilisateur
PDU330AT6L15, PDU330AT6L21
(Numéro de série : AG-00D5)
PDU triphasée 1U en bâti surveillé
avec commutateur de transfert automatique
PDU3VD351
(Numéro de série : AG-00C2)
PDU3V20D354, PDU3V20D354A, PDU3V20D354B
(Numéro de série : AG-013C)
Barre d'alimentation verticale triphasée
1. Consignes de sécurité
importantes
2. Installation
48
5. Utiliser l'affichage
numérique
49
5.1 Naviguer les menus et
les sous-menus d'affichage
2.1 Montage du commutateur de 49
transfert automatique
2.2 Montage de la barre
d'alimentation
57
5.2 Naviguer les menus et les
64
sous-menus de configuration
50
6. Configuration et
fonctionnement
2.3 Raccorder la barre
50
d'alimentation au commutateur
de transfert automatique
66
6.1 Commutateur de transfert
automatique
2.4 Raccorder le commutateur de 51
transfert automatique
7. Service
8. Garantie
2.5 Fonctionnement en réseau du 51
commutateur de transfert
automatique
3. Caractéristiques
4. Affichage numérique
57
52
54
66
68
68
English
1
Español
24
1111 W. 35th Street, Chicago, IL USA 60609 • www.tripplite.com/support
Droits d'auteur © 2015 Tripp Lite. Tous droits réservés.
47
21-03-404-933363.indb 47
4/1/2021 1:10:02 PM
1. Consignes de sécurité importantes
CONSERVEZ CES INSTRUCTIONS.
Ce manuel contient des instructions et des avertissements qui devraient
être respectés pendant l'installation, l'utilisation et l'entreposage de ce
produit. Le non-respect de ces instructions et de ces avertissements
pourrait affecter la garantie du produit.
• La barre d'alimentation fournit plusieurs sorties pratiques, mais ne FOURNIT PAS de protection
contre les surtensions ou les bruits de ligne pour l'équipement branché.
• Ne pas excéder les valeurs nominales suivantes pour l'équipement :
• La pleine charge équilibrée maximale est 13,9 A par banc lorsqu' alimenté par un
commutateur de transfert automatique de 3Φ avec une entrée nominale de 24 A.
• La pleine charge équilibrée maximale est 20 A par banc lorsqu' alimenté par un commutateur
de transfert automatique de 3Φ avec une entrée nominale de 35 A.
• Le commutateur de transfert automatique et la barre d'alimentation sont conçus pour être
utilisés à l'intérieur uniquement, dans un environnement contrôlé, à l'écart de l'excès d'humidité,
des températures extrêmes, des contaminants conducteurs, de la poussière et de la lumière
directe du soleil.
• Maintenir la température intérieure ambiante entre 0 °C et 40 °C (32 °F et 104 °F).
• Le commutateur de transfert automatique et la barre d'alimentation doivent être installés par un
technicien qualifié seulement.
• Ne pas tenter de monter le commutateur de transfert automatique ou la barre d'alimentation sur
une surface précaire ou instable.
• Installer conformément aux codes locaux de l'électricité. S'assurer d'utiliser la bonne protection
contre les surintensités pour l'installation, conformément aux valeurs nominales de la fiche et de
l'équipement.
• Brancher le commutateur de transfert automatique à une prise de courant qui est conforme aux
codes de bâtiment locaux et qui est dûment protégée contre les courants excessifs, les courtscircuits et les défauts à la terre.
• Les prises électriques qui alimentent l'équipement doivent être installées à proximité de
l'équipement et être facilement accessibles.
• Ne pas connecter le commutateur de transfert automatique dans une prise non mise à la masse
ou des rallonges électriques ou des adaptateurs qui éliminent la connexion à la masse.
• S'assurer de fournir un dispositif de déconnexion local pour tous les modèles qui sont installés
en permanence sans fiche facilement accessible.
• Ne jamais essayer d'installer un équipement électrique pendant un orage.
• L'équipement individuel connecté à la barre d'alimentation ne doit pas excéder la charge
nominale des prises individuelles.
• La puissance totale requise pour l'équipement connecté à la barre d'alimentation ne doit pas
excéder la charge nominale maximum pour le commutateur de transfert automatique.
• Ne pas tenter de modifier les fiches d'entrée ou les câbles d'alimentation du commutateur de
transfert automatique ou de la barre d'alimentation.
• Ne pas percer ou tenter d'ouvrir une quelconque partie du commutateur de transfert
automatique ou du boîtier de la barre d'alimentation. Il n'existe aucune pièce réparable par
l'utilisateur à l'intérieur.
• Ne pas tenter d'utiliser le commutateur de transfert automatique ou la barre d'alimentation si
l'une de ses pièces est endommagée.
• Il n'est pas recommandé d'utiliser cet équipement dans les applications de soutien vital où une
panne de cet équipement serait susceptible de causer une panne de l'équipement de soutien
vital ou d'affecter sérieusement sa sécurité ou son efficacité. Ne pas utiliser cet équipement
dans un milieu où il existe un mélange anesthésique inflammable avec de l'air, de l'oxygène ou
de l'oxyde nitreux.
48
21-03-404-933363.indb 48
4/1/2021 1:10:02 PM
2. Installation
2.1 Montage du commutateur de transfert automatique
Important : Le commutateur de transfert automatique doit être installé sur les rails du bâti
dans l'espace U le plus bas disponible (hauteur < 1 m /36 po).
Monter l'équipement sur un bâti à 4 montants ou une enceinte pour bâtis. L'utilisateur doit
déterminer l'aptitude du matériel et des procédures avant le montage. Si la quincaillerie et les
procédures ne conviennent pas à l'application, communiquer avec le fabricant du bâti ou de
l'enceinte pour bâtis. Les procédures décrites dans le présent manuel sont pour les bâtis et les
enceintes pour bâtis de type commun et peuvent ne pas être appropriées pour toutes les applications.
Remarque : Chaque ensemble de rails coulissants à enclenchement consiste d'un support de montage pour
boîtier pour bâtis coulissant et d'un rail à gorge interne. Pour faciliter l'installation, les rails à gorge internes sont
préattachés au commutateur de transfert automatique.
1 Aligner les languettes du support arrière
avec les trous de montage carrés du
boîtier pour bâtis et pousser les crochets
en métal à travers les trous de montage
1A . Pousser ensuite le support arrière
vers le support du boîtier pour que les
languettes bleues puissent enclencher le
montage en place 1B . Aligner ensuite les
languettes du support avant avec les
trous de montage carrés avant du boîtier
pour bâtis. Pousser les crochets en métal
du support avant à travers les trous de
montage et pousser le support avant vers
le support du boîtier pour que les
languettes bleues enclenchent le
montage en place. S'assurer d'installer
le support de montage dans l'espace
U le plus bas.
1A
1B
2 Répéter l'étape un pour le second
support de montage du côté opposé du
boîtier pour bâtis.
3 Une fois les deux supports de montage
fixés sur le boîtier pour bâtis, bien retenir
en place les supports arrière en utilisant
les vis M5X10L incluses.
3
4 Aligner les rails à gorge internes fixés au
commutateur de transfert automatique
avec les supports de montage. Glisser
ensuite l'appareil dans l'ensemble des
rails. Au moyen d'un tournevis, fixer les
vis à oreilles montées sur le panneau du
commutateur de transfert automatique
au boîtier pour bâtis.
4
49
21-03-404-933363.indb 49
4/1/2021 1:10:03 PM
2. Installation
2.2 Montage de la barre d'alimentation
Remarque : Les boutons de montage sont
préinstallés sur la barre d'alimentation pour un
montage sans outil. Un deuxième ensemble de trous
de montage pour boutons sur la barre d'alimentation
permet un positionnement alternatif dans le bâti.
Placer la barre d'alimentation comme souhaité
dans le boîtier à bâtis, aligner les boutons
avec les fentes de montage du bâti et glisser
la barre d'alimentation en place.
Votre modèle peut différer légèrement de l'illustration.
2.3 Raccorder la barre d'alimentation au commutateur de
transfert automatique
La barre d'alimentation comporte un cordon à
7 conducteurs avec une fiche à 8 positions. La
fiche s'installe directement à la prise
d'accouplement du commutateur de transfert
automatique à l'arrière de l'appareil.
Votre modèle peut différer légèrement de l'illustration.
50
21-03-404-933363.indb 50
4/1/2021 1:10:04 PM
2. Installation
2.4 Raccorder le commutateur de transfert automatique
2.4.1 Brancher les fiches d'entrée
du commutateur de transfert
automatique
Remarque : Le commutateur de transfert automatique
est fourni équipé de deux entrées d'alimentation CA
triphasées : source A et source B. La source A est la
source principale par défaut. Consulter la section
Naviguer les menus et les sous-menus de
configuration pour des instructions sur la façon de
changer la source principale. Les instructions
concernant la connexion ci-dessous assument que la
source A est la source principale.
A
B
Brancher la fiche d'entrée de la source A A à
une source d'alimentation CA triphasée
principale. Dans des conditions de fonctionnement normales, le commutateur de transfert
automatique va distribuer de l'alimentation CA depuis la source d'entrée de la source A. Brancher
la fiche d'entrée de la source B B à une source alternative d'alimentation CA mise à la masse. Ne
pas brancher l'entrée de la source B dans la même source d'alimentation que l'entrée de la source
A. Le commutateur de transfert automatique va distribuer de l'alimentation CA depuis l'entrée de la
source B uniquement si l'entrée de la source A devient non disponible ou instable.
2.4.2 Raccorder l'équipement
à la barre d'alimentation
Ne pas dépasser la charge nominale maximale
de la barre d'alimentation. Le courant
électrique total utilisé par chaque phase de la
barre d'alimentation sera affiché en ampères
sur l'ampèremètre numérique
2.5 Fonctionnement en réseau du commutateur de transfert
automatique
Le commutateur de transfert automatique peut se voir assigner des adresses IP via le serveur
DHCP (dynamique) ou par des méthodes d'adressage statique (manuelles). En cas de doute sur la
méthode à utiliser, veuillez contacter l'administrateur du réseau pour obtenir de l'aide avant de
poursuivre le processus d'installation.
Remarque : L'adresse MAC (une chaîne de 12 chiffres dont le format est le suivant : 000667xxxxxx) est
imprimée sur une étiquette fixée au boîtier du commutateur de transfert automatique. Pour l'attribution
d'adresses IP statiques, utiliser le câble de configuration DB9 (730866) inclus avec le commutateur de transfert
automatique.
Le commutateur de transfert automatique fournit une surveillance à distance et beaucoup plus via
un navigateur Web, telnet et des systèmes de gestion de réseau basés sur SNMP. Pour plus
d'information au sujet de la configuration et du fonctionnement du commutateur de transfert
automatique via l'interface du navigateur Web PowerAlert, se reporter au Guide d'utilisateur de la
SNMPWEBCARD en visitant www.tripplite.com/support et en inscrivant SNMPWEBCARD dans le
champ de recherche.
51
21-03-404-933363.indb 51
4/1/2021 1:10:05 PM
3. Caractéristiques
Barre d'alimentation
(PDU3VD351, PDU3V20D354, PDU3V20D354A, PDU3V20D354B)
2 11
1
Commutateur de transfert automatique (PDU330AT6L15/PDU330AT6L21)
4
11
5
10
3
12
8
7
9
6
1 Sorties de la barre d'alimentation : Ces sorties IEC C13 et C19 monophasées sont
alimentées par les connexions d'entrée d'alimentation triphasées entrelacées de la source A
ou de la source B du commutateur de transfert automatique. Ces sorties ne sont pas
contrôlables.
2 Cordon d'alimentation d'entrée de la barre d'alimentation :
Le cordon à 7 conducteurs comporte un connecteur à 8
positions qui s'attache directement au commutateur de transfert
automatique.
52
21-03-404-933363.indb 52
4/1/2021 1:10:07 PM
3. Caractéristiques
3 Entrée de la source A et de la source B du commutateur
de transfert automatique : Les cordons sont attachés en
permanence au commutateur de transfert automatique et
comportent des fiches L15-30P ou L21-30P.
4 Affichage numérique : Affiche l'état de la source, les valeurs
mesurées, les modes d'affichage et d'autres renseignements.
Consulter la section Affichage numérique pour des
explications détaillées sur les indicateurs et les affichages.
L15-30P
5 Bouton de réinitialisation SNMP : Appuyer sur le bouton de
réinitialisation pendant 3 secondes pour redémarrer la carte de
réseau du commutateur de transfert automatique. Le fait de
redémarrer la carte de réseau n'effacera pas les paramètres du
réseau et ne va pas interrompre l'alimentation CA. Le bouton
de réinitialisation est encastré. Utiliser un trombone ou un
autre objet approprié pour l'enfoncer.
6
A
B
L21-30P
Interface réseau : Utiliser la prise RJ-45 pour brancher le commutateur de
transfert automatique au réseau avec un cordon de raccordement Ethernet
standard. Le voyant à DEL Status (état) A et le voyant à DEL Link (lien) B
indiquent les conditions de fonctionnement telles qu'indiquées dans le
tableau ci-dessous. Ces ports en sont pas compatibles pour les applications
nécessitant l'alimentation électrique par câble Ethernet (PoE).
Conditions de fonctionnement du réseau
A Couleur du voyant à DEL Status (état)
B Couleur du voyant à DEL Link (lien)
Off (arrêt)
Carte non initialisée
Off (arrêt)
Aucun raccordement au réseau
Vert solide
Carte initialisée et opérationnelle
Ambre clignotant
Raccordement au réseau de
100 Mbps
Ambre clignotant
Erreur - carte non initialisée
Vert clignotant
Raccordement au réseau de
10 Mbps
7 Port de configuration DB9 : Utiliser ce port pour fournir un raccordement terminal direct à
un ordinateur avec un émulateur de terminal. Un câble série est inclus avec le commutateur
de transfert automatique. Si vous avez besoin de commander un câble de remplacement,
communiquez avec le service à la clientèle de Tripp Lite en visitant www.tripplite.com/support.
8 Sortie pratique IEC-320-C13 : Cette sortie reçoit de l'alimentation de la phase L1-L2, mais
n'est pas contrôlable. Elle contribue à la charge totale L1-L2.
9 Disjoncteurs de sortie pratique IEC-320-C13 : Il y a deux disjoncteurs thermiques pour
protéger chaque côté de la sortie pratique.
10 Disjoncteur : Chaque charge de sortie monophasée a son propre disjoncteur magnétique. Si
la charge de l'équipement connecté dépasse la charge nominale maximale pour cette phase,
le disjoncteur se déclenchera. Débrancher l'équipement excédentaire avant de réinitialiser
le(s) disjoncteur(s).
11 Vis de mise à la terre du châssis : Utilisez cette vis pour brancher n'importe quel
équipement nécessitant une mise à la terre au châssis.
12 Prise d'accouplement du commutateur de transfert automatique : Cette prise accepte
uniquement le connecteur à 8 positions sur le cordon d'alimentation d'entrée de la barre
d'alimentation.
53
21-03-404-933363.indb 53
4/1/2021 1:10:08 PM
4. Affichage numérique
3
1
2
5
4
6
7
8
1 Voyants à DEL Status (état) de la source : Le type d'illumination des voyants à DEL
indique quelle source est la source principale, quelle source est prête à l'utilisation et quelle
source est actuellement utilisée. Consulter la section Indicateurs à DEL Status (état) de
la source pour une explication des types d'illumination des voyants à DEL.
2 Voyant à DEL de disjoncteur déclenché : Allumé lorsqu'un disjoncteur est déclenché.
3 Affichage à 3 chiffres : affiche les valeurs mesurées telles que l'intensité de courant,
kilowatt, tension, pourcentage de déséquilibre de puissance, la fréquence, le facteur de
puissance et la température.
4 Bouton Enter (saisir) : Lorsqu'une option de menu est sélectionnée au moyen du bouton
Enter (saisir), le bouton Enter (saisir) permet de défiler à travers les sous-menu au sein de
chaque catégorie. Les sous-menus sont indiquées par les témoins à DEL.
Remarque : Le fait d'appuyer simultanément sur le bouton Enter (saisir) et Mode pendant 2 secondes
permet d'afficher l'adresse IP.
5 Témoins à DEL : Une DEL allumée indique la valeur qui est affichée sur l'écran à 3 chiffres.
Ampères (A) : Le courant d'entrée sur l'entrée de la source sélectionné (A# ou b#) ou le
circuit de charge de sortie (C#) est affiché en ampères.
Puissance (kW) : La puissance de sortie pour le circuit de charge de sortie sélectionné (C#)
ou la puissance de sortie totale (OP) est affichée en kW.
Tension (V) : La tension d'entrée phase-à-phase de la source A ou B (A# ou b#) ou la
tension du circuit de charge de sortie (C#) est affichée en volts.
Fréquence (Hz) : La fréquence d'entrée de la source A ou B est affichée en Hz.
Facteur de puissance (PF) : Le facteur de puissance de la charge de sortie est affiché en
nombre décimal (de 0 à 1,00).
54
21-03-404-933363.indb 54
4/1/2021 1:10:08 PM
4. Affichage numérique
6 Affichage à 2 chiffres : Cet affichage indique quel mode d'affichage est sélectionné : Phase
d'entrée de la source (A# ou b#), % déséquilibré (Ub), circuits de sortie (C#), puissance de
sortie totale (OP), température (tC ou tF) ou code de défaillance (FC).
Phases de la source A (A#) : Affiche les mesures pour la source A. Ces mesures incluent le
courant (A), la tension (V) et la fréquence (Hz) de la phase.
Phases de la source B (b#) : Affiche les mesures pour la source B. Ces mesures incluent le
courant (B), la tension (V) et la fréquence (Hz) de la phase.
% déséquilibré (Ub) : l'écran affiche la déviance du pourcentage de la charge déséquilibrée
de la valeur moyenne mesurée. Le pourcentage de la phase dont la déviance est la plus
élevée est affiché.
Circuits de sortie (C#) : affiche les mesures pour le circuit de sortie. Ces mesures incluent
le courant (A), les kilowatts (kW), la tension (V) et le facteur de puissance (PF).
Puissance de sortie totale (OP) : affiche la puissance totale sur tous les circuits de sortie.
Température (t) : la température ambiante est affichée lorsque cette option est sélectionnée.
La température est affichée en Celsius par défaut, mais peut être changée en Fahrenheit.
Code de défaillance (FC) : le code de défaillance s'affiche uniquement si un disjoncteur
s'est déclenché.
7 Bouton Mode : permet de défiler à travers les menus Display (affichage) et Config
(configuration). Le choix du menu d'affichage est affiché sur un écran à 2 chiffres. Le choix
du menu de configuration est affiché sur un écran à 3 chiffres.
8 Bouton de réinitialisation SNMP : Appuyer sur le bouton de réinitialisation pendant trois
secondes pour redémarrer la carte de réseau du commutateur de transfert automatique. Le
fait de redémarrer la carte de réseau n'effacera pas les paramètres du réseau et ne va pas
interrompre l'alimentation CA. Le bouton de réinitialisation est encastré. Utiliser un trombone
ou un autre objet approprié pour effectuer une réinitialisation.
55
21-03-404-933363.indb 55
4/1/2021 1:10:08 PM
4. Affichage numérique
Témoins à DEL Status (état) de la source
Description
de l'illumination des voyants à DEL
Voyant à DEL allumé
Voyant à DEL éteint
• Source A principale
Voyant à DEL clignotant
• Les deux sources sont de bonne qualité et disponibles.
• La sortie est raccordée à la source A.
• Source B principale
• Les deux sources sont de bonne qualité et disponibles.
• La sortie est raccordée à la source B.
• Source A principale
• La source A est de mauvaise qualité ou non disponible.
• La sortie est raccordée à la source B.
• Source B principale
• La source B est de mauvaise qualité ou non disponible.
• La sortie est raccordée à la source A.
• Source A principale
• Les sources ont des niveaux de stabilité variés.
Remarque : Cela
se produit très
rarement.
• Les phases de sortie sont alimentées par des sources différentes.
Remarque : un voyant à DEL « disponible » clignotera si les phases de la source ont des niveaux de stabilité
variés.
56
21-03-404-933363.indb 56
4/1/2021 1:10:08 PM
5. Utiliser l'affichage numérique
5.1 Naviguer les menus et les sous-menus d'affichage
(mesure)
Appuyer sur le bouton MODE pour passer au menu d'affichage suivant. Appuyer sur le bouton
Enter (saisir) pour passer au sous-menu suivant (Amps, kW, Volts, Hz, PF). Appuyer et maintenir
le bouton MODE pendant 2 seconds pour passer au premier menu de configuration (se reporter à
la section Naviguer les menus et sous-menus de configuration). Appuyer et maintenir les
boutons MODE et Enter (saisir) pendant 2 secondes pour afficher l'adresse IP de la carte SNMP
connectée. Le type de défilement des menus est décrit ci-dessous.
Source A
Courant de phase (L1)
i.3.2
Ai
2.0.8
Ai
6.0
Ai
Volts (L1-L2)
Remarque : Étant donné qu'il s'agit d'un
modèle de 208 V, les tensions affichées sont
des tensions de phase-à-phase
(p. ex., A1 à l'écran indique la tension L1-L2).
Hz (L1-L2)
57
21-03-404-933363.indb 57
4/1/2021 1:10:09 PM
5. Utiliser l'affichage numérique
Source A
Courant de phase (L2)
i.3.2
A2
2.0.8
A2
6.0
A2
Volts (L2-L3)
Hz (L2-L3)
Source A
Courant de phase (L3)
i.3.2
A3
2.0.8
A3
6.0
A3
Volts (L3-L1)
Hz (L3-L1)
58
21-03-404-933363.indb 58
4/1/2021 1:10:09 PM
5. Utiliser l'affichage numérique
Source B
Courant de phase (L1)
i.3.2
Volts (L1-L2)
2.0.8
Hz (L1-L2)
6.0
Source B
Courant de phase (L2)
i.3.2
Volts (L2-L3)
2.0.8
Hz (L2-L3)
6.0
59
21-03-404-933363.indb 59
4/1/2021 1:10:10 PM
5. Utiliser l'affichage numérique
Source B
Courant de phase (L3)
i.3.2
Volts (L3-L1)
2.0.8
Hz (L3-L1)
6.0
Charge déséquilibrée détectée
% de déséquilibre de phase
i 0.0
Circuit de charge de sortie
Courant du circuit (L1-L2)
i 3.2
Ci
2.7 5
Ci
Kilowatts (L1-L2)
60
21-03-404-933363.indb 60
4/1/2021 1:10:10 PM
5. Utiliser l'affichage numérique
Tension (L1-L2)
Courant du circuit (L1-L2) (Page 60)
208
Ci
Facteur de puissance (L1-L2)
i.0 0
Ci
Circuit de charge de sortie
Courant du circuit (L2-L3)
i 3.2
C2
2.7 5
C2
208
C2
Kilowatts (L2-L3)
Tension (L2-L3)
Facteur de puissance (L2-L3)
i.0 0
C2
61
21-03-404-933363.indb 61
4/1/2021 1:10:11 PM
5. Utiliser l'affichage numérique
Circuit de charge de sortie
Courant du circuit (L3-L1)
i 3.2
C3
2.7 5
C3
208
C3
Kilowatts (L3-L1)
Tension (L3-L1)
Facteur de puissance (L3-L1)
i.0 0
C3
Puissance de sortie totale
Courant de phase de la source A (L1)
(Page 57)
Kilowatts
8.2 5
OP
Température
tC = Celsius; tF = Fahrenheit
25
62
21-03-404-933363.indb 62
4/1/2021 1:10:11 PM
5. Utiliser l'affichage numérique
Menu des codes de défaillance
Le menu des codes de défaillance est uniquement disponible lorsqu'un disjoncteur s'est déclenché,
entraînant l'illumination du voyant à DEL de disjoncteur déclenché. L'affichage passera au menu
des codes de défaillance et défilera automatiquement à travers les disjoncteurs déclenchés (seuls
les disjoncteurs déclenchés seront affichés dans la séquence de défilement. L'option de défilement
manuel est toujours disponible, mais la fonction de défilement automatique demeurera active sur
le menu des codes de défaillance lorsqu'une défaillance est présente. Si le défilement automatique
est désactivé, l'affichage passera au menu des codes de défaillance, mais il faut défiler
manuellement à travers chaque disjoncteur déclenché individuellement. Le chiffre sur l'affichage à
3 chiffres est défini de la façon suivante : br1 = disjoncteur de sortie L1-L2; br2 = disjoncteur de
sortie L2-L3; br3 = disjoncteur de sortie L3-L1
Disjoncteur 1 déclenché
FC
Disjoncteur 2 déclenché
FC
Disjoncteur 3 déclenché
FC
Affichage de l'adresse IP
Il est possible d'appuyer et de maintenir à tout moment les boutons Mode et Enter (saisir) pendant
2 secondes pour afficher l'adresse IP de la carte SNMP connectée. L'affichage à 3 chiffres affichera
« IP ». L'affichage à 2 chiffres à sa droite affichera un chiffre de l'adresse IP à la fois jusqu'à ce qu'il
affiche l'ensemble de l'adresse IP. Les virgules décimales et les deux-points seront affichés sous
forme de traits d'union. Remarque : Cet écran prend en charge les adresses IPv4 ET IPv6. L'écran
va automatiquement revenir au mode dans lequel il se trouvait avant d'afficher l'adresse IP.
IP
I
63
21-03-404-933363.indb 63
4/1/2021 1:10:12 PM
5. Utiliser l'affichage numérique
5.2 Naviguer les menus et les sous-menus de configuration
(configuration)
Depuis un menu d'affichage, appuyer et maintenir le bouton Mode pendant 2 secondes pour
accéder au premier menu de configuration. Appuyer sur le bouton Mode pour revenir par cycle au
prochain menu de configuration. Appuyer et maintenir le bouton Mode pendant 2 seconds pour
passer aux modes Display (affichage).
Options d'unités de température
C–F
F
C–F
C
Maintenir le bouton Enter (saisir) pendant 2
secondes pour passer d'une option à une
autre. La lettre sur l'affichage à 2 chiffres
indique l'unité sélectionnée, C pour Celsius et
F pour Fahrenheit
2 secondes
Sélection de la source principale
PSS
Maintenir le bouton Enter (saisir) pendant
2 secondes pour passer de la source A à la
source B. La lettre dans l'affichage à 2 chiffres
indique la source choisie.
A
Remarque : Si les deux sources sont disponibles,
l'appareil passera immédiatement à la source
principale une fois que le paramètre est changé.
2 secondes
PSS
Auto Scroll (défilement automatique) activé/désactivé
Lorsque la fonction Auto Scroll (défilement
automatique) est activé, elle revient par cycle
à travers les menus des courants du circuit de
charge de sortie (C1, C2, C3) par intervalles
de 4 secondes. « y » indique que la fonction
est activée; « n » indique qu'elle est
désactivée. Le fait d'appuyer sur un bouton
quelconque interrompt la fonction de
défilement automatique, ce qui permet à
l'utilisateur de naviguer entre les options de
menus. Si aucun bouton n'est enfoncé, il y a
une pause de 10 secondes et le défilement
automatique reprendra depuis le menu actuel.
2 secondes
64
21-03-404-933363.indb 64
4/1/2021 1:10:12 PM
5. Utiliser l'affichage numérique
Luminosité des voyants à DEL
Maintenir le bouton Enter (saisir) enfoncé pendant 2 secondes pour défiler parmi chaque option de
luminosité. Le chiffre sur l'affichage à 2 chiffres est défini de la façon suivante : 1=25 %; 2=50
%; 3=75 %; 4=100 %.
Remarque : L'option de luminosité par défaut est 4 (100 %).
4
2 secondes
i
2 secondes
2
2 secondes
3
2 secondes
Essai de voyants à DEL
Maintenir le bouton Enter (saisir) pendant 2
secondes pour initier un essai de voyant à
DEL. Tous les voyants à DEL s'allumeront
pendant 6 secondes.
Options d'unités de température (Page 64)
2 secondes
8.8.8.
88
65
21-03-404-933363.indb 65
4/1/2021 1:10:13 PM
6. Configuration et fonctionnement
6.1 Commutateur de transfert automatique
Lorsque les entrée de la source A et de la source B sont toutes les deux raccordées aux sources
d'alimentation, le commutateur de transfert automatique fonctionne comme un commutateur de
transfert automatique, fournissant de l'alimentation d'entrée redondante pour les applications à
disponibilité élevée. Dans des conditions de fonctionnement normales, le commutateur de transfert
automatique va distribuer de l'alimentation depuis la source d'entrée principale et commuter à la
source d'entrée secondaire dans des conditions anormales. La source principale par défaut est la
source A (Consulter la section Naviguer les menus et les sous-menus de configuration pour
des instructions sur la façon de changer la source principale.) Le commutateur de transfert
automatique va commuter à la source principale lorsqu'elle est « bonne » en vertu des définitions
de la tension d'entrée du commutateur de transfert automatique (voir la section 6.1.2).
6.1.1 Configuration principale
La fonction commutateur de transfert automatique fournit une disponibilité accrue lorsque les
entrées de la source A et de la source B du commutateur de transfert automatique sont
raccordées à des sources séparées de l'alimentation du secteur. Pour une disponibilité maximum, il
est recommandé, lorsque des onduleurs sont utilisés, que les onduleurs correspondent à la sortie
d'ondes sinusoïdales pures pour les sources d'alimentation d'entrée source A et source B. La
fonction commutateur de transfert automatique sera compromis si les entrées de la source A et de
la source B sont raccordées à la même source de l'alimentation du secteur.
Utilité B
Circuit utilitaire
Utilité A
Circuit utilitaire
Source d'alimentation
d'entrée B
Cordon d'alimentation d'entrée B
Source d'alimentation
d'entrée A
Cordon d'alimentation d'entrée A
208V~ / L1
- L2
5A OUTPUT
BREAKER
Commutateur de
transfert automatique
Charges des
appareils
Barre
d'alimentation
66
21-03-404-933363.indb 66
4/1/2021 1:10:14 PM
6. Configuration et fonctionnement
6.1.2 Sélection de la source pour le commutateur de transfert
automatique
Le commutateur de transfert automatique va démarrer et fournir une sortie si la tension de l'une
des sources d'entrée est supérieure à la tension minimum de démarrage. Lors du fonctionnement
normal, lorsque les deux sources sont de qualité semblable (« suffisante » ou « bonne »), l'appareil
va sélectionner la source principale en fonction du paramètre de sélection de la source principale
(se reporter à la section Menus et sous-menus de configuration). Si la qualité de la source
actuellement sélectionnée se dégrade pour devenir moindre que la source actuellement non
sélectionnée, l'appareil va commuter vers la source de meilleure qualité. Si la qualité de la source
actuellement non sélectionnée s'améliore pour devenir supérieure à la source actuellement
sélectionnée, l'appareil va commuter vers la source de meilleure qualité.
Remarque : Dans l'éventualité d'une perte de tension sur l'un des conducteurs d'entrée triphasés, les charges
connectées au connecteur de phase défectueux seront commutées vers la source alternative. La charge restante
suivra et commutera vers la source alternative dans un délai de 1 seconde. Si les deux sources ont des niveaux
de stabilité variés dans leurs phases, chaque charge sélectionnera sa propre source d'entrée en fonction de la
meilleure disponible. Si les 3 phases de l'une des sources redeviennent de « bonne » qualité, l'appareil
commutera alors toutes les phases vers cette source.
Gammes de tensions d'entrée
Tension nominale
208 V
Tension minimum de démarrage
163 V
Bonne gamme de tension
172 à 241 V
Gamme de tension suffisante
144 à 171 V
Mauvaise gamme de tension
0 à 143 V
6.1.3 Essai rapide
Après avoir installé le commutateur de transfert automatique/la
barre d'alimentation et raccordé l'équipement, la fonction du
commutateur de transfert automatique peut subir un essai en
mettant temporairement hors tension l'entrée CA principale (la
source par défaut est la source A). Le commutateur de transfert
automatique commutera ensuite de l'entrée principale à l'entrée
alternative. Lorsque l'entrée principale recommence à fournir
l'alimentation, le commutateur de transfert automatique
commutera de nouveau à l'entrée principale.
Remarque : Les deux entrées doivent être branchées à des sources
séparées de l'alimentation du secteur. La fonction commutateur de transfert
automatique sera compromis si les deux entrées sont raccordées à la
même source de l'alimentation. Ne pas effectuer d'essai sur l'équipement
devant demeurer en opération pour maintenir une production quelconque.
Toute procédure d'essai doit prévoir et parer à l'éventualité que l'équipement
puisse être soumis à une coupure de courant. Ne pas effectuer d'essais du
commutateur de transfert automatique en débranchant les cordons
d'alimentation qui sont branchés à des sources d'alimentation sous tension,
puisque ceci coupe la connexion à la terre et expose l'équipement à des
risques.
Source principale (A) active
Source alternative (B) active
67
21-03-404-933363.indb 67
4/1/2021 1:10:15 PM
7. Service
Votre produit Tripp Lite est couvert par la garantie décrite dans ce manuel. Une variété de
programmes de garantie prolongée et de service d'entretien sont également disponibles par
Tripp Lite. Pour plus d'informations sur le service, visitez www.tripplite.com/support. Avant de
retourner votre produit pour le service, procédez comme suit :
1. Passez en revue les procédures d'installation et de fonctionnement dans ce manuel afin de vous
assurer que le problème ne provient pas d'une mauvaise interprétation des instructions.
2. Si le problème persiste, ne communiquez pas et ne renvoyez pas le produit chez le
concessionnaire. Visitez plutôt www.tripplite.com/support.
3. Si le problème nécessite une réparation, visitez www.tripplite.com/support et cliquez sur le lien
Demande de retour (RMA). De là, vous pouvez demander une autorisation de retour de matériel
(RMA), qui est requise pour le service. Ce simple formulaire en ligne vous demandera le modèle
de votre appareil et le numéro de série, ainsi que d'autres informations générales. Le numéro RMA
ainsi que des instructions d'expédition vous seront envoyés par courriel. Les dommages (directs,
indirects, particuliers ou consécutifs) encourus par le produit lors du transport à Tripp Lite ou à un
service autorisé Tripp Lite ne sont pas couvert par la garantie. Les frais liés au transport des
produits expédiés à Tripp Lite ou à un centre de service autorisé Tripp Lite doivent être entièrement
payés d'avance. Inscrivez le numéro de RMA à l'extérieur de l'emballage. Si le produit est dans sa
période de garantie, joignez une copie de votre reçu de caisse. Retournez le produit pour réparation
par un transporteur assuré à l'adresse qui vous est donnée lorsque vous demandez le « RMA ».
8. Garantie
GARANTIE LIMITÉE
Le vendeur garantit que ce produit, s'il est utilisé conformément à toutes les instructions applicables, est exempt de tous défauts de
matériaux et de fabrication pour une période de 3 ans à partir de la date d'achat initiale. Si le produit s'avère défectueux en raison
d'un vice de matière ou de fabrication au cours de cette période, le vendeur s'engage à réparer ou remplacer le produit, à sa seule
discrétion. Le service sous cette garantie ne peut être obtenue qu'en livrant ou en expédiant le produit (avec tous les frais
d'expédition ou de livraison prépayés) à : Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 États-Unis. Le vendeur paiera les frais
d'expédition de retour. Visitez www.tripplite.com/support avant d'envoyer de l'équipement pour réparation.
CETTE GARANTIE NE S'APPLIQUE PAS À L'USURE NORMALE OU AUX DOMMAGES RÉSULTANT D'UNE MAUVAISE UTILISATION, D'UN
ABUS OU D'UNE NÉGLIGENCE. LE VENDEUR NE DONNE AUCUNE GARANTIE EXPRESSE AUTRE QUE LA GARANTIE EXPRESSÉMENT
DÉCRITE DANS LE PRÉSENT DOCUMENT. SAUF DANS LA MESURE INTERDITE PAR LA LOI APPLICABLE, TOUTE GARANTIE IMPLICITE,
Y COMPRIS TOUTES LES GARANTIES DE QUALITÉ MARCHANDE OU D'ADAPTATION, SONT LIMITÉES À LA PÉRIODE DE GARANTIE
CI-DESSUS ET CETTE GARANTIE EXCLUT EXPRESSÉMENT TOUS DOMMAGES DIRECTS ET INDIRECTS. (Certains états ne permettent
pas de limitations sur la durée d'une garantie implicite, et certains états ne permettent pas l'exclusion ou la limitation des
dommages fortuits ou consécutifs, de sorte que les limitations ou exclusions susmentionnées peuvent ne pas s'appliquer à vous.
Cette garantie vous donne des droits légaux spécifiques, et vous pouvez avoir d'autres droits qui varient selon la juridiction).
AVERTISSEMENT : L'utilisateur individuel doit prendre soin de déterminer avant l'utilisation si cet appareil est approprié, adéquat et sûr
pour l'usage prévu. Puisque les utilisations individuelles sont sujettes à des variations importantes, le fabricant ne fait aucune
déclaration ou garantie quant à l'aptitude ou l'adaptation de ces dispositifs pour une application spécifique.
Numéros d'identification à la conformité réglementaire
À des fins de certification de conformité réglementaire et d'identification, un numéro de série unique a été attribué à votre produit
Tripp Lite. Le numéro de série ainsi que toutes les marques d'homologation et les informations requises se trouvent sur l'étiquette
de produit. Lorsque vous demandez des informations concernant la conformité de ce produit, reportez-vous toujours au numéro de
série. Le numéro de série ne doit pas être confondu avec le nom de la marque ou le numéro de modèle du produit.
Informations sur la conformité DEEE pour les clients et les recycleurs de Tripp Lite (Union européenne)
En vertu de la directive et des règlements d'application relatifs aux déchets d'équipements électriques et électroniques
(DEEE), lorsque des clients achètent de l'équipement électrique et électronique neuf de Tripp Lite, ils ont droit :
• d'envoyer le vieil équipement au recyclage en autant qu'il remplace un équipement équivalent
(cela varie selon les pays)
• de retourner le nouvel équipement afin qu'il soit recyclé à la fin de sa vie utile
La politique de Tripp Lite en est une d'amélioration continue. Les spécifications sont sujettes à changement sans préavis.
1111 W. 35th Street, Chicago, IL USA 60609 • www.tripplite.com/support
68
21-03-404-933363.indb 68
21-03-404 93-3363_RevD
4/1/2021 1:10:15 PM