Legrand RS-250-N Universal Guía de instalación

Tipo
Guía de instalación
Installation Instructions
Please read all instructions before installing
DESCRIPTION AND OPERATION
The RS-250-N Universal Application Wall Switch Vacancy Sensor is designed to
replace a standard light or fan switch. It is ideal for living and dining rooms, family
rooms, bedrooms, bathrooms and any other indoor area in a residential space
where occupancy sensor-based manual ON/OFF controls are desirable.
Like a standard switch, you press the ON/OFF button to turn the light or
fan (controlled load) ON and OFF. Unlike a standard switch, the RS-250-N
automatically turns OFF the controlled load after the coverage area has been
vacant for a period of time (Time Delay). If motion is detected within 30 seconds
after it automatically turns OFF, the RS-250-N automatically turns the load back
ON.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation,
it can be adjusted to work as an Occupancy Sensor that turns the controlled load
ON automatically upon detection of occupancy in the area.
Night Light
While the controlled load is OFF, the nightlight built into the RS-250-N is ON.
When the load is ON, the nightlight is OFF.
Operating Modes
There are two operating modes to select from during set up:
MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press
the ON/OFF button to turn the load ON. The RS-250-N keeps the load ON until no
motion is detected for the selected time delay period (adjustable from 15 seconds
to 30 minutes). There is a 30 second reset delay. If motion is detected during this
time, the sensor turns the load back on automatically. After the reset delay time
has elapsed, the ON/OFF button must be pressed to turn ON the load.
MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset to
auto after 5 minutes of vacancy): The load turns ON and OFF automatically based
on occupancy detection. The RS-250-N keeps the load ON until no motion is
detected for the selected time delay period. If the load is turned OFF manually,
automatic-ON is re-enabled when no motion is detected for 5 minutes. This
prevents the load from being turned ON after it was deliberately turned OFF.
RS-250-N
Universal Application Wall Switch
Vacancy Sensor
with Manual ON/OFF
and Nightlight
Lens
ON/OFF button
SPECIFICATIONS
Voltage ...............................................................120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent or fl uorescent ............................ 0-600 Watts
Fan motor .................................................................. 1/6 hp
Time Delay Adjustment ....................15 seconds to 30 minutes
Light Level Adjustment .......................................10 fc to 150 fc
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
Santa Clara, CA 95050
Call 888.817.0571 for Technical Support
Nightlight
Time Delay
The time delay can be selected by the user during set up. It can be adjusted
from 15 seconds up to 30 minutes. For additional information on how to adjust
it, please read the SENSOR ADJUSTMENT & PROGRAMMING section of this
installation manual.
Light Level
When the sensor is set for occupancy sensor Mode
2 (Auto-ON/OFF) the light level feature prevents
the sensor from automatically turning the lights
ON if there is already enough light in the area. To
adjust the light level, please read the SENSOR
ADJUSTMENT & PROGRAMMING section of this
installation manual.
Coverage Area
The RS-250-N has a maximum range of 180 degrees
and a coverage area of 600 sq. feet (56 sq. meters).
The sensor must have a clear and unobstructed
view of the coverage area. Objects blocking the
sensor’s lens may prevent detection thereby
causing the light to turn OFF even though
someone is in the area.
Windows, glass doors, and other transparent barriers will obstruct
the sensor’s view and prevent detection.
INSTALLATION & WIRING
WARNING
Disconnect power to the wall switch box by turning OFF
the circuit breaker or removing the fuse for the circuit before installing
the RS-250-N, replacing lamps, or doing any electrical work.
1. Prepare the switch box.
After the power is turned OFF at the circuit
breaker box, remove the existing wall plate and
mounting screws. Pull the old switch out from the
wall box.
2. Identify the type of circuit.
In a Single Pole Circuit (see Fig. 2), two single
wires connect to two screws on the existing
switch. A ground wire may also be present and
connected to a ground terminal on the old switch.
A neutral wire should also be present in the wall
box.
CAUTION - FOR YOUR SAFETY: Connecting a proper ground to the
sensor provides protection against electrical shock in the event of
certain fault conditions. If a proper ground is not available, consult
with a qualifi ed electrician before continuing installation.
Only connect the RS-250-N to a Single Pole Circuit. The RS-250-N is not
suitable for 3-way switching. If the existing wiring does not match the
description for a Single Pole Circuit, you should consult with a qualifi ed
electrician.
3. Prepare the Wires.
Tag the wires connected to the existing switch, so
that they can be identifi ed later. Disconnect the
wires. Make sure the insulation is stripped off the
wires to expose their copper cores to the length
indicated by the “Strip Gage,” (in Fig. 3) (approx.
1/2 inch).
www.wattstopper.com/athome
Ground
HOT (power from
circuit box)
LOAD
(power
to lamp)
NEUTRAL
Fig. 2: Typical Single
Pole Switch
Wiring
Strip Gage
1/2"
12.7 mm
Fig. 3: Wire
Stripping
25'
(7.6m)
12'
(3.7m)
Fig. 1: Sensor Coverage Area
4. Wire the sensor.
Twist the existing wires
together with the wire leads
on the RS-250-N sensor as
indicated below. Cap them
securely using the wire
nuts provided (See Fig 4).
Connect the green or non-
insulated (copper) GROUND
wire from the circuit to the
green terminal on the RS-
250-N.
Connect the NEUTRAL
wire from the circuit and
from the lamp (LOAD) to
the white wire on the RS-
250-N.
Connect the power wire
from the circuit box (HOT) to the
black wire on the RS-250-N.
Connect the power wire to the lamp (LOAD)
to the red wire on the RS-250-N.
5. Put the RS-250 in the wall box.
Position the lens above the ON/OFF button
(lens at top, button at bottom) and secure it
to the wall box with the screws provided.
6. Restore power to the circuit.
Turn ON the breaker or replace the fuse.
7. Test the sensor’s operation.
See TEST MODE.
8. Review SENSOR ADJUSTMENT &
PROGRAMMING below.
If you want to make adjustments, follow the
instructions in SENSOR ADJUSTMENT & PROGRAMMING, below.
9. Attach the new cover plate.
Secure it to the wall box with the screws provided.
SENSOR ADJUSTMENT &
PROGRAMMING
To program the RS-250-N, you use controls
located under the ON/OFF button. The wall
switch cover plate must be removed to gain
access to the mode button and adjustment
trimpots under the ON/OFF button.
1. Firmly grasp the side edges of the
Lock Bar and gently pull it away from
the switch face until it clicks. Do NOT
attempt to pull the Lock Bar off of the
switch!
2. Firmly grasp the side edges of the ON/
OFF button. Slide the button downward
approximately 1/2 inch to expose the
mode button and adjustment trimpots.
Setting up the Operating Mode
Select the operating mode by pressing the
Mode button. The nightlight blinks to indicate
the selected mode:
One blink indicates Mode 1 (Vacancy Sensor Operation), Manual-ON/OFF,
Auto-OFF
Two blinks indicate Mode 2 (Occupancy Sensor Operation), Auto-ON/OFF w/
manual control and reset to auto (after 5 minutes of vacancy)
To change the mode, press the Mode button once to set the unit to mode 1 or
press the Mode button twice to set the unit to mode 2. The LED blinks to indicate
the selected mode. It repeats the selected mode three times. After that, the unit
operates in the indicated mode.
Adjusting the Time Delay
Turn the right trimpot counter-clockwise to reduce the amount of time the load
will remain on after the last motion detection (minimum = 15 seconds). Turn the
same trimpot clockwise to increase this time delay (maximum = 30 minutes).
Warning: Do not overturn the time delay adjustment trimpot!
TOP
INDOOR USE ONLY
Lock Bar
Mode Button
& Adjustment
Trimpots
Slide down
ON/OFF
Button
Time Delay
15
minutes
Mode
Level
06006r1
1–Manual
2–Auto-ON
Fig. 5: Sensor Adjustment Controls
TOP
Green
>
GROUND
Terminal
Black
>
HOT (power
from circuit box)
L
L
White
>
NEUTRAL
Red
>
LOAD (power
to lamp or fan)
Fig. 4: Sensor orientation, wire connections
and wall box assembly
Initial Power-up Delay
There is an initial warm-up
period the fi rst time power is
applied to the unit and after
a power failure lasting more
than 5 minutes. If the sensor
is in Mode 2, (automatic-ON) it
may take up to 1 minute before
the lights turn ON. However,
the lights can be turned
ON/OFF manually by pressing
the ON/OFF button at any time
when power is supplied to
the unit.
Adjusting the Light Level
This feature is factory set at maximum, so that even the brightest light will not
prevent the sensor from turning the load ON when it detects occupancy. If this
feature is not needed, leave the light level at maximum, fully clockwise.
1. The light level must be adjusted when lights would normally be turned OFF
because there is enough natural illumination.
2. Set the sensor to Mode 2 and reduce the time delay to 15 seconds.
3. Adjust the light level to minimum. Let the sensor time out so lights are OFF
and then wait 30 seconds more.
4. Without casting a shadow on the sensor, enter the area. The lights should
remain OFF.
5. Adjust the light level trimpot clockwise in small increments. Wait 5-10 seconds
after each adjustment to see if the lights turn ON. Continue this procedure
until the lights turn ON. At this setting the lights will not turn ON automatically
with occupancy if the light level is above the current natural illumination.
6. Reset the time delay to the desired setting.
Warning: Do not overturn the light level adjustment trimpot!
TEST MODE
To test the detection coverage:
During the TEST mode, the controlled load turns ON for 5 seconds each time the
sensor detects occupancy.
1. Press and hold the ON/OFF button. After 10 seconds the nightlight fl ashes. The
load turns ON if it was not already ON. The sensor is now in a TEST mode that
lasts 5 minutes. (You can end the TEST mode sooner by pressing the ON/OFF
button for another 10 seconds).
2. Move out of the coverage area or stand very still. The controlled load turns OFF
after 5 seconds if no motion is detected.
3. Move into the coverage area. The controlled load turns ON for 5 seconds
each time the sensor detects motion. After 5 seconds expire without motion
detection, the load turns OFF. The controlled load turns ON automatically with
the next motion detection and stays on for 5 seconds.
4. Repeat as necessary to ensure that the desired coverage areas are within
detection range.
TROUBLESHOOTING
Nightlight is OFF, no load response to ON/OFF button press:
Make certain that the circuit breaker is on and functioning.
Nightlight is ON, no load response to ON/OFF button press:
Check the light bulb and/or motor switch on the fan mechanism.
Load will not turn ON automatically when the area is occupied and the
sensor is in Mode 2 (nightlight is ON):
Press ON/OFF button. If the load turns ON, check the light level setting and
also make sure the sensor lens is not blocked. The light level can prevent the
sensor from turning on the load automatically.
If the load does not turn ON when you press the ON/OFF button, check the light
bulb and/or motor switch on the fan mechanism.
Load will not turn OFF automatically:
Press ON/OFF button. If the controlled load turns OFF, go to next step.
The time delay can be set from 30 seconds to 30 minutes. Ensure that there is
no movement within the sensor’s view for the set time period. Hot air currents
and heat radiant devices can cause false detection. Make sure the sensor is at
least 6 feet (2 meters) away from devices that are a signifi cant heat source (e.g.
heater, heater vent, high wattage light bulb).
If load does not respond properly after following troubleshooting, turn OFF
power to the circuit then check wire connections or call technical support.
WARRANTY INFORMATION
Watt Stopper/Legrand warranties its products to be free of defects in materials
and workmanship for a period of fi ve (5) years. There are no obligations or
liabilities on the part of Watt Stopper/Legrand for consequential damages arising
out of, or in connection with, the use or performance of this product or other
indirect damages with respect to loss of property, revenue or profi t, or cost of
removal, installation or reinstallation.
2800 De La Cruz Boulevard, Santa Clara, CA 95050
Technical Support: 888.817.0571
www.wattstopper.com/athome
06020r2 5/2009
Instrucciones de Instalación
Por favor leer todas las instrucciones antes de realizar la instalación
DESCRIPCION Y OPERACION
El Sensor de Desocupación de pared confi gurable RS-250-N esta diseñado para
sustituir un interruptor de luz convencional o el interruptor de un ventilador.
Es ideal para salas y comedores, cuartos de televisión, dormitorios, baños y
cualquier otra área en una residencia donde se deseen controles manuales de
ENCENDIDO/APAGADO con detección de ocupación.
Igual que con un interruptor convencional, usted presiona el botón de
ENCENDIDO/APAGADO para encender o apagar la luz o ventilador (carga
controlada). Sin embargo, el RS-250-N apagará automáticamente la carga
controlada cuando el área de cobertura ha permanecido desocupada por un
período de tiempo defi nido como Retardo de Apagado. Si se detecta movimiento
durante los siguientes 30 segundos después de que la carga se ha apagado
automáticamente, el RS-250-N la encenderá nuevamente en forma también
automática.
Aun cuando el sensor vendrá confi gurado de fábrica para funcionar como un
Sensor de Desocupación (es decir, que requiere de encendido manual por el
usuario), el mismo puede ser confi gurado para operar como un Sensor de
Ocupación que encenderá automáticamente la carga en el preciso instante en que
detecte ocupación en su área de cobertura.
Luz Nocturna
Cuando la carga controlada se encuentra apagada, la Luz Nocturna del
RS-250-N se encuentra encendida. Cuando por el contrario la carga controlada
se encuentra encendida la Luz Nocturna se encuentra apagada.
Modos de Operación
Es posible elegir entre dos modos de operación durante la instalación y
confi guración del sensor:
MODO 1 Sensor de Desocupación (ENCENDIDO/APAGADO manual, APAGADO
AUTOMATICO): el usuario debe presionar el botón de ENCENDIDO/APAGADO para
encender la carga. El RS-250-N mantendrá la carga encendida hasta que deje de
detectar movimiento por un período de tiempo igual al predefi nido como Retardo
de Apagado (confi gurable desde 15 segundos hasta 30 minutos). Existe un
periodo de 30 segundos, inmediatamente después de que la carga se ha apagado
automáticamente, durante el cual el sensor la encenderá nuevamente en forma
automática si éste detecta movimiento. Si transcurren más de 30 segundos, será
necesario presionar el botón de ENCENDIDO/APAGADO nuevamente para poder
encender la carga.
RS-250-N
Sensor de Desocupación
de pared confi gurable
con Luz Nocturna y
control manual de
ENCENDIDO/APAGADO
ESPECIFICACIONES
Voltaje ............................................................................ 120VAC, 60Hz
Carga (Circuito unipolar)
Lámparas incandescentes o fl uorescentes .......................... 0-600 Watts
Un motor ................................................................................... 1/6 hp
Ajuste del Retardo de Apagado ....... desde 15 segundos hasta 30 minuto
Ajuste del Nivel de Luz Natural. ......................................... 10 fc to 150 fc
Condiciones de operación. ..........Solo para uso residencial en interiores
Temperatura .................................................32° to 131°F (0° to 55°C)
Humedad ...........................95% Humedad relativa, sin condensación
Herramientas necesarias
Desatornillador con aislamiento
Peladora de cable
Santa Clara, CA 95050
Llame al 888.817.0571 para recibir asistencia técnica
Lente
Botón de
ENCENDIDO/APAGADO
Luz Nocturna
MODO 2 Sensor de Ocupación (ENCENDIDO/APAGADO automático con
control manual y retorno a ENCENDIDO AUTOMATICO después de 5 minutos de
desocupación): la carga se enciende y se apaga automáticamente por detección
de ocupación. El RS-250-N mantiene la carga encendida hasta que deje de
detectar movimiento por un periodo de tiempo igual al defi nido como Retardo
de Apagado. Si la carga es apagada manualmente, la operación de ENCENDIDO
AUTOMATICO se reestablece después de que el sensor no ha detectado
movimiento por 5 minutos. Esto evita que la carga se encienda cuando la misma
ha sido apagada manualmente por elección del usuario.
Tiempo de Retardo de Apagado
El tiempo de Retardo de Apagado puede ser confi gurado por el usuario durante
la instalación del producto. Para el mismo se pueden elegir valores desde 15
segundos hasta 30 minutos. Para información adicional sobre cómo realizar lo
anterior, por favor lea la sección de CONFIGURACION Y PROGRAMACION DEL
SENSOR en este instructivo de instalación.
Nivel de Luz Natural
Cuando el sensor está confi gurado para operar
en Modo 2 como un sensor de ocupación
(ENCENDIDO/APAGADO automático) el ajuste del
Nivel de Luz Natural evita que el sensor encienda
automáticamente las luces si existe sufi ciente luz
natural en la habitación. Para ajustar el Nivel de Luz
Natural por favor lea la sección de CONFIGURACION
Y PROGRAMACION DEL SENSOR en este instructivo
de instalación.
Area de Cobertura
El RS-250-N tiene un rango de cobertura máximo de
180 grados, y cubre un área de 600 pies cuadrados
(56 metros cuadrados). El RS-250-N debe poder
tener visibilidad completa y sin obstrucciones del
área de cobertura. La carga podría apagarse aun cuando alguien se encuentre
dentro del área de cobertura si existen objetos bloqueando el lente del sensor y
por tanto evitando que el mismo detecte movimiento.
Ventanas, puertas de vidrio, y otras barreras transparentes obstruirán
la cobertura del sensor y evitarán que exista detección.
INSTALACION Y CABLEADO
ADVERTENCIA
Desconecte la corriente que alimenta la caja de conexiones apagando
el disyuntor (breaker) o removiendo el fusible para el circuito
correspondiente antes de instalar el RS-250-N, reemplazar luces,
o realizar cualquier trabajo eléctrico.
1. Prepare la caja de conexiones.
Después de haber desconectado la corriente
eléctrica a nivel del disyuntor (breaker) del circuito
correspondiente, retire la placa del interruptor y
los tornillos de montaje. Extraiga el interruptor
existente de la caja.
2. Identifique el tipo de circuito.
En un Circuito Unipolar (ver Fig. 2), dos cables
independientes se conectan a dos tornillos en
el interruptor existente. Un cable de conexión a
tierra también puede estar presente en la caja de
conexiones y conectado a la terminal de tierra del
interruptor. Así mismo, un cable de neutro debería
estar presente en la caja.
CUIDADO: Por su propia seguridad: el conectar el sensor apropiadamente a
tierra provee protección contra un choque eléctrico que pueda ocurrir en caso
de una operación defectuosa. Si no hay disponibilidad de una conexión a tierra
consulte con un electricista califi cado antes de continuar con la instalación.
Conecte el RS-250-N únicamente a un Circuito Unipolar. El RS-250-N no está
diseñado para operar en una confi guración tipo “3 vías” (3-way). Si el cableado
existente en la caja de conexiones no concuerda con la descripción de un
Circuito Unipolar, usted debe consultar con un electricista califi cado.
3. Prepare los cables.
Ponga algún identifi cador en cada uno de los cables actualmente existentes
en la caja de conexiones de tal forma que pueda identifi carlos posteriormente.
Desconecte los cables. Asegúrese de que el aislante del cable se encuentra
pelado apropiadamente para exponer el interior de alambre de cobre a un
Fig. 1: Patrón de cobertura
del sensor
www.wattstopper.com/athome
Tierra
LINEA/FASE (proveniente de la
caja de disyuntores o
“breakers”)
CARGA
(alimentación de
corriente
a la carga)
NEUTRO
Fig. 2: Cableado típico
de un Circuito
25'
(7.6m)
12'
(3.7m)
largo de aproximadamente 1/2 pulgada y de
acuerdo a como se indica en esta guía de longitud
Fig. 3.
4. Conecte el sensor.
Tuerza conjuntamente los cables existentes en
la caja de conexiones con los cables del sensor
RS-250-N utilizando los conectores (“wire nuts”)
provistos de acuerdo al
diagrama Fig. 4.
Conecte el cable verde
(o alambre de cobre sin
aislante) que conecta a
TIERRA a la terminal verde
del RS-250-N.
Conecte el cable de
conexión a NEUTRO del
circuito y de la lámpara o
ventilador (CARGA) al cable
blanco del RS-250-N.
Conecte el cable de LINEA
(o FASE) del circuito al
cable negro del RS-250-N.
Conecte el cable que
alimenta la lámpara o
ventilador (CARGA) al cable
rojo del RS-250-N.
5. Coloque el RS-250-N
dentro de la caja
de conexiones.
El lente debe quedar posicionado arriba del botón de ENCENDIDO/APAGADO.
Asegure el sensor a la caja con los tornillos provistos.
6. Reactive la corriente eléctrica en el circuito.
Encienda el disyuntor (breaker) del circuito o reinstale el fusible.
7. Compruebe el funcionamiento del sensor.
Lea la sección de MODO DE PRUEBA.
8. Revise la sección de CONFIGURACION Y
PROGRAMACION DEL SENSOR.
Si desea modifi car la
confi guración del producto,
siga las instrucciones de la
sección de CONFIGURACION
& PROGRAMACION DEL
SENSOR.
9. Monte la nueva placa
decorativa.
Asegure el sensor a la caja
con los tornillos provistos.
CONFIGURACION Y
PROGRAMACION DEL
SENSOR
Para con gurar el sensor RS-250-N
usted debe utilizar los controles
ubicados detrás del botón de
ENCENDIDO/APAGADO. Es necesario
desmontar la placa decorativa para
obtener acceso al Botón de Selección
de Modos y a las Perillas de Ajuste.
1. Tome la Barra de Seguridad
rmemente por ambos extremos y
jálela hacia afuera delicadamente.
No trate de despegarla
completamente del sensor!
2. Tome rmemente el botón de
ENCENDIDO/APAGADO por ambos
extremos y deslícelo hacia abajo
aproximadamente 1/2 pulgada de
tal forma que el Botón de Selección
de Modos y las Perillas de Ajuste
queden expuestas.
TOP
INDOOR USE ONLY
Barra de Seguridad
Botón de Selección
de Modos y Perillas
de Ajuste
Deslice el Botón de
ENCENDIDO/APAGADO
Time Delay
15
minutes
Mode
Level
06006r1
1–Manual
2–Auto-ON
Fig. 5: Controles de ajuste
Strip Gage
1/2"
12.7 mm
Fig. 3: Pelado
apropiado del
cable
TOP
Terminal
>
TIERRA
Verde
Negro
>
LINEA/FASE
(proveniente de la caja
de disyuntores o
"breakers")
L
L
Blanco
>
NEUTRO
Rojo
>
CARGA
(alimentación
de corriente
a la carga)
Fig. 4: Orientación del sensor, conexión de
cables y montaje del producto en la
caja de conexiones
Retardo Inicial de Operación
Existe un periodo de tiempo, inmediatamente
después de que se habilita la corriente al
sensor, ya sea durante su instalación inicial
o después de una falla de corriente que dure
más de 5 minutos, durante el cual el sensor
no encenderá la carga automáticamente si
este se encuentra en Modo de operación 2
(ENCENDIDO/APAGADO Automático). Esto
se debe a un periodo de calentamiento
inicial necesario que puede durar hasta 1
minuto. Durante este intervalo de tiempo, sin
embargo, continúa siendo posible encender
o apagar las luces manualmente con solo
presionar el botón de ENCENDIDO/APAGADO.
Selección del Modo de Operación
Seleccione el Modo de Operación presionando el Botón de Selección de Modos.
La Luz Nocturna parpadeará en un patrón determinado que le indicará el modo
seleccionado:
Un patrón de un solo parpadeo repetido 3 veces, indicará Modo 1 (Operación
como Sensor de Desocupación), ENCENDIDO/APAGADO manual, APAGADO
automático.
Un patrón de dos parpadeos consecutivos, repetido 3 veces, indicará Modo 2
(Operación como Sensor de Ocupación), ENCENDIDO/APAGADO automático
con control manual y retorno a ENCENDIDO Automático después de 5 minutos
de desocupación.
Para cambiar de modo, presione el Botón de Selección de Modos: una sola vez
para Modo 1 ó dos veces para Modo 2. El LED parpadeará una ó dos veces, según
sea Modo 1 ó Modo 2. El LED repetirá el patrón seleccionado tres veces. Después
de eso, la unidad estará programada para operar en el modo seleccionado.
Ajuste del Retardo de Apagado
Gire la perilla izquierda en dirección contraria a las manecillas del reloj para
reducir el tiempo que permanecerá encendida la carga después de la última
detección de movimiento (valor mínimo = 15 segundos). Gire la misma perilla en
sentido de las manecillas del reloj para incrementar el Retardo de Apagado (valor
máximo = 30 minutos).
Advertencia: No sobregire la perilla de ajuste del Retardo de Apagado!
Ajuste del Nivel de Luz Natural
Esta función vendrá confi gurada de fábrica a su valor máximo de tal forma que
aun la luz natural más brillante no evitará que el sensor ENCIENDA la carga
cuando este detecte ocupación. Si no se requiere de esta función, deje el ajuste
de Nivel de Luz Natural en su valor máximo.
1. El ajuste del nivel de luz natural debe realizarse en un determinado momento
en el que exista sufi ciente luz natural como para que usted considere
innecesario mantener encendida la luz artifi cial.
2. Coloque el RS-250-N en Modo de Operación 2 y reduzca el tiempo de retardo
de apagado a 15 segundos.
3. Mueva la perilla de Ajuste de Nivel de Luz Natural a su valor mínimo, salga
de la habitación y deje que el sensor apague las luces después del retardo de
apagado de 15 segundos.
4. Espere 30 segundos más y luego ingrese nuevamente a la habitación tratando
de no crear una sombra sobre el sensor. Esta vez, las luces deben permanecer
apagadas.
5. Gire la perilla de Ajuste de Nivel de Luz Natural en sentido de las manecillas
de reloj y en pequeños incrementos. Después de cada ajuste, espere entre 5 y
10 segundos para ver si las luces se encienden. Continúe este procedimiento
hasta que las luces se enciendan. A este valor de ajuste, las luces no se
encenderán automáticamente con la detección de ocupación si la cantidad de
luz natural es mayor a la existente actualmente.
6. Reajuste el tiempo de retardo de apagado al valor deseado.
Advertencia: No sobregire la perilla de ajuste del Nivel de Luz Natural!
MODO DE PRUEBA
Para probar la cobertura del sensor:
Durante el modo de PRUEBA, la carga controlada por el sensor se encenderá por
5 segundos cada vez que el sensor detecta movimiento.
1. Oprima y mantenga oprimido el botón de ENCENDIDO/APAGADO. Después
de transcurridos 10 segundos la Luz Nocturna parpadeará. La carga se
encenderá si no estaba ya encendida. El sensor se encuentra ahora en modo
de PRUEBA, el cual durará 5 minutos (usted puede sacar el sensor de modo
de PRUEBA en cualquier momento presionando el botón de ENCENDIDO/
APAGADO por otros 10 segundos más).
2. Movilícese fuera del área de cobertura o permanezca inmóvil. La carga
controlada se apagará después de 5 segundos si el sensor no detecta
movimiento.
3. Movilícese dentro del área de cobertura. La carga controlada se encenderá
por 5 minutos cada vez que el sensor detecte movimiento. Después de
transcurridos 5 segundos de no detección, la carga se apagará. La carga
se encenderá automáticamente con la próxima detección y se mantendrá
encendida por otros 5 segundos.
4. Repita según sea necesario para asegurarse que el área que se desea cubrir
con el sensor se encuentra dentro del rango de cobertura del mismo.
INFORMACION SOBRE LA GARANTIA DE PRODUCTO
Watt Stopper/Legrand garantiza que sus productos están libres de defectos
en sus materiales y ensamble por un período de cinco (5) años. No existen
obligaciones o responsabilidades por parte de Watt Stopper / Legrand por daños
ocasionados por o en conexión con el uso o desempeño de este producto u otros
daños indirectos en materia de pérdida de propiedad, ventas o ganancias, o
costos por retiro, instalación o desinstalación.
2800 De La Cruz Boulevard, Santa Clara, CA 95050
Asistencia Técnica: 888.817.0571
www.wattstopper.com/athome
06020r2 5/2009
SOLUCION DE PROBLEMAS
La carga no se enciende cuando usted presiona el botón de
ENCENDIO/APAGADO y la Luz Nocturna no está iluminada:
Asegúrese de que el disyuntor (breaker) del circuito funcione y que se
encuentre encendido.
La carga no se enciende cuando usted presiona el botón de
ENCENDIDO/APAGADO, pero la Luz Nocturna sí está iluminada:
Revise el bombillo (lámpara incandescente) y/o el interruptor del motor del
ventilador
La carga no se enciende automáticamente cuando el área es ocupada
y el sensor está configurado para operar en Modo 2 (la Luz
Nocturna sí está iluminada):
Presione el botón de ENCENDIDO/APAGADO. Si la carga controlada se
enciende, revise la confi guración del Nivel de Luz Natural. Esta función puede
evitar que el sensor encienda en forma automática.
Si al presionar el botón de ENCENDIDO/APAGADO la carga no se
enciende:
Revise el bombillo (lámpara incandescente) y/o el interruptor del motor del
ventilador.
La carga no se apaga automáticamente:
Presione el botón de ENCENDIDO/APAGADO. Si la carga se apaga, prosiga con
el siguiente paso.
El tiempo del retardo de apagado puede ser confi gurado desde 30 segundos
hasta 30 minutos. Asegúrese de que el tiempo de retardo de apagado se
encuentra confi gurado al valor deseado y de que no haya movimiento a
detectar dentro del área de cobertura del sensor hasta que ese intervalo
de tiempo haya transcurrido. Corrientes de aire caliente y radiadores de
calor pueden ocasionar falsas detecciones. Asegúrese que el sensor se
encuentra alejado al menos 6 pies (2 metros) de dispositivos que sean fuentes
considerables de calor (por ejemplo: radiadores, salidas de aire caliente,
lámparas de alta potencia)
Si la carga no se comporta apropiadamente después de haber
realizado los pasos anteriores, desconecte la corriente al circuito
desde el disyuntor (breaker) y revise las conexiones de los cables
o llame al 888.817.0571 para recibir asistencia técnica.