Lux TX500E-010 Guía de instalación

Categoría
Termostatos
Tipo
Guía de instalación
(TX500E) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS
(TX500E) ESPAÑOL – IDENTIFICACION DE CABLES Y DIAGRAMAS DE CABLEADO
(TX500E) FRANÇAIS – IDENTIFICATION DES FILS ET SCHÉMAS DE CÂBLAGE
R
V
HEATING ONLY SYSTEMS COOLING ONLY SYSTEMS
4 & 5 WIRE WITH ONE TRANSFORMER 5 & 6 WIRE WITH TWO TRANSFORMERS
HEATING / COOLING SYSTEMS HEATING / COOLING SYSTEMS
RH Y WRC G O B
OPTIONAL
JUMPER
PROVIDED
R
RH
V
5
W
H
4
G
F
JUMPER
PROVIDED
W
H
4
Y
C*
6
G
F
R
RH
RC
V
5
Y
C*
6
G
F
R
RC
RH
V
5
O
OPTIONAL
OPTIONAL
B*
W
H
4
Y
C*
6
G
F
RH
R
RC
5
JUMPER
PROVIDED
R
RC
V
5
G
F
Y
C*
6
RC-RH JUMPER
PROVIDED
USE "B" OR "O"
NOT BOTH
*CUSTOMER
SUPPLIED
JUMPER
JUMPER
( REMOVED )
TYPICAL SINGLE STAGE
HEAT PUMP WIRING
RH Y WRC G O B
RH
Y
W
RC
GOB
RH
Y
W
RC
GOB
RH
Y
W
RC
GOB
O BY WRH RC G
FAN
GAS
VA LV E
OR
HEATER
SYSTEM
XFMR
TYPICAL 2, 3, OR 4-WIRE, 24-VOLT
HEATING ONLY SYSTEMS
AND MILIVOLT HEATING SYSTEMS
O BY WRH RC G
FAN
A/C
COMPRESSOR
SYSTEM
XFMR
TYPICAL 3 AND 4-WIRE, 24-VOLT
COOLING ONLY SYSTEMS
O BY WRH RC G
FAN
A/C
COMPRESSOR
GAS
VA LV E
OR
HEATER
SYSTEM
XFMR
TYPICAL 4 AND 5-WIRE, 24-VOLT
HEATING AND COOLING SYSTEMS
WITH ONE TRANSFORMER
O BY WRH RC G
FAN
TYPICAL 5 AND 6-WIRE, 24-VOLT
HEATING AND COOLING SYSTEMS
WITH TWO TRANSFORMERS
A/C
COMPRESSOR
GAS
VA LV E
OR
HEATER
HEAT
XFMR
COOL
XFMR
O BY WRH RC G
HEAT
PUMP
UNIT
FAN
REVERSING
VA LV E
SYSTEM
XFMR
TYPICAL 4-WIRE, 24-VOLT
SINGLE STAGE HEAT PUMP SYSTEMS
WIRING DIAGRAM NOTES:
• All of the dashed wires are optional, and usage depends upon your specific
system type. Use either the “B” or the “O” wire, but not both. Generally, the B
and O terminals are only used for Heat Pump systems.
• If replacing a Honeywell TM-11, tape off the “R” wire. Connect the “B” wire
to the “RH” terminal.
• If replacing a thermostat that has a clock wire labeled as “C,” tape off this
wire and do not connect it to this thermostat.
• If “Y” and “C” wires are both present, then “C” is a common wire, do not
connect it to this thermostat.
• If a “B” wire in your system is a common wire, connecting it to the “B”
terminal of this thermostat may damage your system and the thermostat, tape it
off and do not connect it.
RV
SYSTÈMES DE CHAUFFAGE SEUL SYSTÈMES DE CLIMATISATION SEULE
4 OU 5 FILS ET UN TRANSFORMATEUR 5 OU 6 FILS ET DEUX TRANSFORMATEURS
SYSTÈMES DE CHAUFFAGE/CLIMATISATION SYSTÈMES DE CHAUFFAGE/CLIMATISATION
RH Y WRC G O B
OPTIONNEL
CAVALIER FOURNI
R
RH
V
5
W
H
4
G
F
CAVALIER FOURNI
W
H
4
Y
C*
6
G
F
R
RH
RC
V
5
Y
C*
6
G
F
R
RC
RH
V
5
O
OPTIONNEL
OPTIONNEL
B*
W
H
4
Y
C*
6
G
F
RH
R
RC
5
CAVALIER FOURNI
R
RC
V
5
G
F
Y
C*
6
CAVALIER RC-RH
FOURNI
UTILISER « B » OU « O »,
MAIS NON LES DEUX
*CAVALIER
FOURNI
PAR LE CLIENT
(CAVALIER RETIRÉ)
CÂBLAGE POUR POMPE DE CHALEUR MONOÉTAGÉE
RH Y WRC G O B
RH
Y
W
RC
GOB
RH Y WRC G O B
RH
Y
W
RC
GOB
O BY WRH RC G
SYSTÈMES DE CHAUFFAGE SEUL
DE 24 VOLTS À 2, 3 OU 4 FILS ET
SYSTÈMES DE CHAUFFAGE À MINIVOLTS
ROBINET DE GAZ
OU APPAREIL
DE CHAUFFAGE
VENTILATEUR
TRANSFORMATEUR
SYSTÈME
O BY WRH RC G
SYSTÈMES DE CLIMATISATION SEULE
DE 24 VOLTS À 3 OU 4 FILS
COMPRESSEUR C.A.
VENTILATEUR
TRANSFORMATEUR
SYSTÈME
O BY WRH RC G
SYSTÈMES DE CHAUFFAGE ET DE
CLIMATISATION DE 24 VOLTS À 4 OU 5 FILS
AVEC UN TRANSFORMATEUR
COMPRESSEUR
C.A.
VENTILATEUR
TRANSFORMATEUR
SYSTÈME
ROBINET DE GAZ
OU APPAREIL
DE CHAUFFAGE
O BY WRH RC G
SYSTÈMES DE CHAUFFAGE ET DE
CLIMATISATION DE 24 VOLTS À 5 OU 6 FILS
AVEC DEUX TRANSFORMATEURS
COMPRESSEUR
C.A.
VENTILATEUR
TRANSFORMATEUR
CHAUFFAGE
ROBINET DE GAZ
OU APPAREIL
DE CHAUFFAGE
TRANSFORMATEUR
CLIMATISATION
O BY WRH RC G
SYSTÈMES À POMPE DE CHAUFFAGE
MONOÉTAGÉE DE 24 VOLTS À 4 FILS
POMPE DE
CHAUFFAGE
ROBINET
D’INVERSION
VENTILATEUR
TRANSFORMATEUR
SYSTÈME
RV
SISTEMAS DE CALEFACCION
SOLAMENTE
SISTEMAS DE AIRE ACONDICIONADO
SOLAMENTE
4 Y 5 ALAMBRES CON UN TRANSFORMADOR 5 Y 6 ALAMBRES CON DOS TRANSFORMADORES
SISTEMAS DE CALEFACCION/
AIRE ACONDICIONADO
SISTEMAS DE CALEFACCION/
AIRE ACONDICIONADO
RH Y WRC G O B
OPCIONAL
SE INCLUYE LA CONEXION DE PUENTE
R
RH
V
5
W
H
4
G
F
SE INCLUYE LA CONEXION DE PUENTE
W
H
4
Y
C*
6
G
F
R
RH
RC
V
5
Y
C*
6
G
F
R
RC
RH
V
5
O
OPCIONAL
OPCIONAL
B*
W
H
4
Y
C*
6
G
F
RH
R
RC
5
SE INCLUYE LA CONEXION DE PUENTE
R
RC
V
5
G
F
Y
C*
6
SE INCLUYE CONEXION
DE PUENTE RC-RH
USE “B” U “O” PERO NO AMBOS
*CONEXION DE PUENTE
PROVISTA POR EL CLIENTE
(CONEXION DE PUENTE RETIRADA)
CABLEADO TIPICO DE UNA BOMBA DE CALOR DE UNA FASE
RH Y WRC G O B
RH
Y
W
RC
GOB
RH Y WRC G O B
RH
Y
W
RC
GOB
O BY WRH RC G
SISTEMAS TIPICOS DE CALEFACCION SOLAMENTE
DE 24 VOLTIOS DE 2, 3 O 4 ALAMBRES
Y SISTEMAS DE CALEFACCION DE MILIVOLTIOS
CALENTADOR
O VALVULA
DE GAS
VENTILADOR
XFMR DEL
SISTEMA
O BY WRH RC G
SISTEMAS TIPICOS DE AIRE ACONDICIONADO
SOLAMENTE DE 24 VOLTIOS DE 3 Y 4 ALAMBRES
COMPRESOR
DE AIRE
ACONDICIONADO
VENTILADOR
XFMR DEL
SISTEMA
O BY WRH RC G
SISTEMAS TIPICOS DE CALEFACCION
Y AIRE ACONDICIONADO DE 24 VOLTIOS
DE 4 Y 5 ALAMBRES CON UN TRANSFORMADOR
COMPRESOR
DE AIRE
ACONDICIONADO
CALENTADOR
O VALVULA
DE GAS
VENTILADOR
XFMR DEL
SISTEMA
O BY WRH RC G
SISTEMAS TIPICOS DE CALEFACCION
Y AIRE ACONDICIONADO DE 24 VOLTIOS
DE 5 Y 6 ALAMBRES CON DOS TRANSFORMADORES
COMPRESOR
DE AIRE
ACONDICIONADO
CALENTADOR
O VALVULA
DE GAS
VENTILADOR
XFMR DE
CALEFACCION
XFMR DE AIRE
ACONDICIONADO
O BY WRH RC G
SISTEMAS TIPICOS DE BOMBA DE CALOR
DE UNA FASE DE 24 VOLTIOS DE 4 ALAMBRES
VENTILADOR
XFMR DEL
SISTEMA
UNIDAD DE
LA BOMBA
DE CALOR
VALVULA
DE 4 VIAS
NOTES SUR LES SCHÉMAS DE CÂBLAGE :
• Tous les fils pointillés sont optionnels; leur présence dépend du système
installé. Utiliser « B » ou « O », mais non les deux. En règle générale, les bornes
B et O sont utilisées uniquement avec les systèmes à pompe de chauffage.
• Si le thermostat remplacé était un Honeywell TM-11, ne pas raccorder le fil R
et le recouvrir de ruban électrique. Raccorder le fil B à la borne RH.
• Si le thermostat remplacé comportait un fil d’horloge étiqueté C, ne pas
raccorder le fil C au thermostat et le recouvrir.
• Si les fils Y et C sont tous deux présents, le fil C est un fil commun. Ne pas le
raccorder au thermostat.
• Si dans votre système le fil B est le fil commun, le fait de le raccorder à la
borne B de ce thermostat peut endommager le système et le thermostat. Ne pas
le raccorder et le recouvrir.
NOTAS SOBRE LOS DIAGRAMAS DE CABLEADO:
• Todos los alambres de trazo discontinuo son opcionales y el uso depende del tipo
de su sistema específico. Use el alambre “B” o el “O”, pero no ambos.
Generalmente, los terminales B y O se usan solamente para sistemas de bombas de
calor.
• Si va a reemplazar un Honeywell TM-11, coloque cinta sobre el alambre “R”.
Conecte el alambre “B” al terminal “RH”.
• Si va a reemplazar un termostato que tiene un alambre para el reloj marcado con
una “C”, coloque una cinta sobre este alambre y no lo conecte a este termostato.
• Si existen los dos alambres “Y” y “C”, entonces “C” es un alambre común, no lo
conecte a este termostato.
• Si el alambre “B” de su sistema es un alambre común, conectarlo al terminal “B”
de su termostato puede dañar su sistema y el termostato, coloque una cinta sobre
el mismo y no lo conecte.
52073

Transcripción de documentos

52073 (TX500E) ENGLISH - WIRE IDENTIFICATION AND WIRING SCHEMATICS HEATING ONLY SYSTEMS COOLING ONLY SYSTEMS JUMPER PROVIDED TYPICAL 2, 3, OR 4-WIRE, 24-VOLT HEATING ONLY SYSTEMS AND MILIVOLT HEATING SYSTEMS JUMPER PROVIDED RH RC Y W G O B RH RC Y W G O B RH RC Y W RH V 5 H 4 R Y G RC V 5 C* 6 F G OPTIONAL R F HEATING / COOLING SYSTEMS G GAS VALVE OR HEATER SYSTEM XFMR O B RH RC Y W G O B RH RC Y HEAT XFMR FAN COOL XFMR W G O GAS VALVE OR HEATER A/C COMPRESSOR B FAN Y W G RH RC Y W G C* 6 H 4 V R R F C* 6 H 4 F TYPICAL 4-WIRE, 24-VOLT SINGLE STAGE HEAT PUMP SYSTEMS TYPICAL 3 AND 4-WIRE, 24-VOLT COOLING ONLY SYSTEMS B RH RC Y R O 5 & 6 WIRE WITH TWO TRANSFORMERS JUMPER ( REMOVED ) W G HEATING / COOLING SYSTEMS 4 & 5 WIRE WITH ONE TRANSFORMER JUMPER PROVIDED RH RC Y W TYPICAL 5 AND 6-WIRE, 24-VOLT HEATING AND COOLING SYSTEMS WITH TWO TRANSFORMERS W G O RH RC Y B W G O B RH RC V 5 5 SYSTEM XFMR A/C COMPRESSOR FAN HEAT PUMP UNIT SYSTEM XFMR REVERSING VALVE FAN TYPICAL SINGLE STAGE HEAT PUMP WIRING RC-RH JUMPER PROVIDED *CUSTOMER SUPPLIED JUMPER RH RC Y W G O B Y G C* 6 F O B* OPTIONAL R OPTIONAL RH RC Y RC RH V 5 WIRING DIAGRAM NOTES: TYPICAL 4 AND 5-WIRE, 24-VOLT HEATING AND COOLING SYSTEMS WITH ONE TRANSFORMER SYSTEM XFMR W G O GAS VALVE OR HEATER A/C COMPRESSOR USE "B" OR "O" NOT BOTH • All of the dashed wires are optional, and usage depends upon your specific system type. Use either the “B” or the “O” wire, but not both. Generally, the B and O terminals are only used for Heat Pump systems. • If replacing a Honeywell TM-11, tape off the “R” wire. Connect the “B” wire to the “RH” terminal. • If replacing a thermostat that has a clock wire labeled as “C,” tape off this wire and do not connect it to this thermostat. • If “Y” and “C” wires are both present, then “C” is a common wire, do not connect it to this thermostat. • If a “B” wire in your system is a common wire, connecting it to the “B” terminal of this thermostat may damage your system and the thermostat, tape it off and do not connect it. B FAN (TX500E) FRANÇAIS – IDENTIFICATION DES FILS ET SCHÉMAS DE CÂBLAGE SYSTÈMES DE CHAUFFAGE SEUL SYSTÈMES DE CLIMATISATION SEULE CAVALIER FOURNI RH RC Y W G O B RH RC Y W G O B W G R OPTIONNEL RH RC Y R RC RH V 5 H 4 V 5 F SYSTÈMES DE CHAUFFAGE/CLIMATISATION G C* 6 F TRANSFORMATEUR SYSTÈME (CAVALIER RETIRÉ) G ROBINET DE GAZ OU APPAREIL DE CHAUFFAGE Y W RC V C* H 5 6 4 O RH RC Y B TRANSFORMATEUR CHAUFFAGE VENTILATEUR W O B RH RC Y SYSTÈMES DE CLIMATISATION SEULE DE 24 VOLTS À 3 OU 4 FILS W G O G RH RC Y W V R C* H R 5 6 4 G O O B VENTILATEUR ROBINET DE GAZ OU APPAREIL DE CHAUFFAGE SYSTÈMES À POMPE DE CHAUFFAGE MONOÉTAGÉE DE 24 VOLTS À 4 FILS B W G COMPRESSEUR C.A. TRANSFORMATEUR CLIMATISATION RH RC Y R G 5 OU 6 FILS ET DEUX TRANSFORMATEURS CAVALIER FOURNI W W SYSTÈMES DE CHAUFFAGE/CLIMATISATION 4 OU 5 FILS ET UN TRANSFORMATEUR RH RC Y Y SYSTÈMES DE CHAUFFAGE ET DE CLIMATISATION DE 24 VOLTS À 5 OU 6 FILS AVEC DEUX TRANSFORMATEURS SYSTÈMES DE CHAUFFAGE SEUL DE 24 VOLTS À 2, 3 OU 4 FILS ET SYSTÈMES DE CHAUFFAGE À MINIVOLTS CAVALIER FOURNI B RH RC Y G W G O B RH F F TRANSFORMATEUR SYSTÈME COMPRESSEUR C.A. VENTILATEUR TRANSFORMATEUR SYSTÈME CÂBLAGE POUR POMPE DE CHALEUR MONOÉTAGÉE CAVALIER RC-RH FOURNI *CAVALIER FOURNI PAR LE CLIENT RH RC Y W G O SYSTÈMES DE CHAUFFAGE ET DE CLIMATISATION DE 24 VOLTS À 4 OU 5 FILS AVEC UN TRANSFORMATEUR B RH RC Y R Y G W G O B B* O V C* 5 6 OPTIONNEL RH F OPTIONNEL RC TRANSFORMATEUR SYSTÈME UTILISER « B » OU « O », MAIS NON LES DEUX ROBINET DE GAZ OU APPAREIL DE CHAUFFAGE COMPRESSEUR C.A. VENTILATEUR POMPE DE CHAUFFAGE ROBINET D’INVERSION VENTILATEUR NOTES SUR LES SCHÉMAS DE CÂBLAGE : • Tous les fils pointillés sont optionnels; leur présence dépend du système installé. Utiliser « B » ou « O », mais non les deux. En règle générale, les bornes B et O sont utilisées uniquement avec les systèmes à pompe de chauffage. • Si le thermostat remplacé était un Honeywell TM-11, ne pas raccorder le fil R et le recouvrir de ruban électrique. Raccorder le fil B à la borne RH. • Si le thermostat remplacé comportait un fil d’horloge étiqueté C, ne pas raccorder le fil C au thermostat et le recouvrir. • Si les fils Y et C sont tous deux présents, le fil C est un fil commun. Ne pas le raccorder au thermostat. • Si dans votre système le fil B est le fil commun, le fait de le raccorder à la borne B de ce thermostat peut endommager le système et le thermostat. Ne pas le raccorder et le recouvrir. (TX500E) ESPAÑOL – IDENTIFICACION DE CABLES Y DIAGRAMAS DE CABLEADO SISTEMAS DE AIRE ACONDICIONADO SOLAMENTE SISTEMAS DE CALEFACCION SOLAMENTE SE INCLUYE LA CONEXION DE PUENTE RH RC Y W G SE INCLUYE LA CONEXION DE PUENTE O B RH RC Y W G O B SISTEMAS TIPICOS DE CALEFACCION SOLAMENTE DE 24 VOLTIOS DE 2, 3 O 4 ALAMBRES Y SISTEMAS DE CALEFACCION DE MILIVOLTIOS RH RC Y W RH V 5 H 4 G OPCIONAL R F SISTEMAS DE CALEFACCION/ AIRE ACONDICIONADO 4 Y 5 ALAMBRES CON UN TRANSFORMADOR W G Y G RC V 5 C* 6 F CALENTADOR O VALVULA DE GAS XFMR DEL SISTEMA 5 Y 6 ALAMBRES CON DOS TRANSFORMADORES (CONEXION DE PUENTE RETIRADA) O O B B RH RC Y W G O Y W G RH RC Y W G C* 6 H 4 F V R R 5 C* 6 H 4 F RH RC Y XFMR DE CALEFACCION VENTILADOR W SISTEMAS TIPICOS DE AIRE ACONDICIONADO SOLAMENTE DE 24 VOLTIOS DE 3 Y 4 ALAMBRES G COMPRESOR DE AIRE ACONDICIONADO O B VENTILADOR CALENTADOR O VALVULA DE GAS XFMR DE AIRE ACONDICIONADO SISTEMAS TIPICOS DE BOMBA DE CALOR DE UNA FASE DE 24 VOLTIOS DE 4 ALAMBRES B RH RC Y R G SISTEMAS DE CALEFACCION/ AIRE ACONDICIONADO SE INCLUYE LA CONEXION DE PUENTE RH RC Y R W SISTEMAS TIPICOS DE CALEFACCION Y AIRE ACONDICIONADO DE 24 VOLTIOS DE 5 Y 6 ALAMBRES CON DOS TRANSFORMADORES W G O B RH RC Y W G O B RH RC V 5 XFMR DEL SISTEMA COMPRESOR DE AIRE ACONDICIONADO VENTILADOR XFMR DEL SISTEMA CABLEADO TIPICO DE UNA BOMBA DE CALOR DE UNA FASE RH RC Y W G O B R Y G O C* 6 F OPCIONAL RH RC Y RC RH V 5 W G O B B* USE “B” U “O” PERO NO AMBOS VENTILADOR VALVULA DE 4 VIAS NOTAS SOBRE LOS DIAGRAMAS DE CABLEADO: SISTEMAS TIPICOS DE CALEFACCION Y AIRE ACONDICIONADO DE 24 VOLTIOS DE 4 Y 5 ALAMBRES CON UN TRANSFORMADOR *CONEXION DE PUENTE PROVISTA POR EL CLIENTE OPCIONAL SE INCLUYE CONEXION DE PUENTE RC-RH UNIDAD DE LA BOMBA DE CALOR XFMR DEL SISTEMA COMPRESOR DE AIRE ACONDICIONADO CALENTADOR O VALVULA DE GAS VENTILADOR • Todos los alambres de trazo discontinuo son opcionales y el uso depende del tipo de su sistema específico. Use el alambre “B” o el “O”, pero no ambos. Generalmente, los terminales B y O se usan solamente para sistemas de bombas de calor. • Si va a reemplazar un Honeywell TM-11, coloque cinta sobre el alambre “R”. Conecte el alambre “B” al terminal “RH”. • Si va a reemplazar un termostato que tiene un alambre para el reloj marcado con una “C”, coloque una cinta sobre este alambre y no lo conecte a este termostato. • Si existen los dos alambres “Y” y “C”, entonces “C” es un alambre común, no lo conecte a este termostato. • Si el alambre “B” de su sistema es un alambre común, conectarlo al terminal “B” de su termostato puede dañar su sistema y el termostato, coloque una cinta sobre el mismo y no lo conecte.
  • Page 1 1

Lux TX500E-010 Guía de instalación

Categoría
Termostatos
Tipo
Guía de instalación