Fantech PB270-2 Installation and Maintenance Manual

Tipo
Installation and Maintenance Manual

Este manual también es adecuado para

Installation and Maintenance Manual
Manuel pour l'Installation et l'Entretien
Manual de Instalación y Mantenimiento
Item #: 412889
Rev Date: 080113
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
PB Series
Premium Bath Fans
(single grille unit 4" duct PB110*, PB110F, PB110H; single and dual grille units 6" duct PB190*,
PB270-2*, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2)
Ventilareurs pour salle de bains premium
(grille simple conduit de 4 po PB110*, PB110F, PB110H; grille simple et double conduit de 6 po
PB190*, PB270-2, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2)
Ventiladores Para Baño Premium
(unidades de Reja Solas 4" conducto PB110*, PB110F, PB110H, unidades de reja solas y duales 6"
Conducto PB190*, PB270-2, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2)
fantech
*
* The following models earned the ENERGY STAR® by meeting strict
fciency guidelines set by Natural Resources Canada and the US EPA.
2
fantech
Note Warning /
Important
note
Information Technical
information
Practical tip
Before installation, servicing or
cleaning unit, switch power off at
service panel and lock the service
disconnect to prevent power from being
switched on accidentally. When the service
disconnect cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel.
1. The compactness and adaptability of the FG
Series fans permit easy installation. The fans are
shipped fully assembled and can be
mounted at any angle. For various mounting, see
figures on the following page.
2. Because this unit has rotating parts, safety
precautions should be exercised during all phases
of installation, operation and maintenance.
3. CAUTION: “For General Ventilation Use Only. Do
Not Use To Exhaust Hazardous Or Explosive
Material and Vapors.”
4. Remove unit from package and inspect within
15 days after receipt. If damaged, report damage
to carrier. Do Not operate this unit with visible
damage to the blower or impeller
assembly.
5. CAUTION: “This unit has an unguarded impeller.
Do not use in locations readily accessible to
people or animals.”
WEAR HAND PROTECTION AND STAY CLEAR OF
SHARP EDGES!
6. Screen guards must be installed within reach of
personnel, within (7) feet of the working area, or
when advisable for safety.
7. CAUTION: Bulb used in fluorescent models not
dimmable.
8. CAUTION: Use only Fantech Fluorescent bulb
(model PBB14) and PAR16 / MR16 GU10 50W
max. halogen bulbs (model PBB50).
9. PLEASE read the entire manual before installing.
Avant l’installation, le service ou le nettoyage,
coupez l’électricité au compteur électrique et
fermez-le à clé afin d’éviter que l’électricité ne
soit retranchée accidentellement. Quand le
tableau de contrôle ne peut pas être fermer à
clé, afficher un dispositif d’avertissement bien
en vue, comme une étiquette par exemple placée
sur le tableau électrique.
1. La compacité et l’adaptabilité des ventilateurs
FG permettent une installation facile. Les
ventilateurs sont envoyés complètement
assemblés et peuvent être montés sur N’importe
quel angle. Pour les montages différents veuillez
voir les pages suivantes.
2. Cet appareil contient des parties rotatives, des
mesures de sécurités doivent être observées lors
de l’installation et l’entretien.
3. PRECAUTION: A utiliser strictement pour une
ventilation normale. A NE PAS UTILISER POUR
évacuer des vapeurs de matériaux dangereux ou
explosifs.
4. Retirer l’appareil de son emballage et
inspectez-le dans les 15 jours qui suivent sa
réception. S’il est endommagé, rapporter les
dommages à l’envoyeur. Ne Pas utilisez cet
appareil avec un dommage apparent sur le
souffleur ou le système de ventilation.
5. PRECAUTION: “Cet appareil a un ventilateur de
projection non protégé. Ne pas l’utiliser dans un
endroit où il peut êtreaccessible aux personnes ou
aux animaux.”
PORTEZ DES GANTS ET ESSAYER D’EVITER LES BORDS
COUPANTS!
6. Un écran de protection doit être installé hors
d’atteinte du per sonnel à 7 feet (2 mètres
environ) de la zone de travail oudans des limites
raisonnables de sécurité.
7. PRECAUTION:
Les ampoules utilis
é
es dans les
mod
é
les fluorescents ne sont pas r
é
glables.
8. Attention: Utilisez seulement les ampoules «tcp
xr3014 b» pour les modÈles fluorescents et les
ampoules «par 16» pour les modèles halogènes.
9. VEUILLEZ, lire ce manuel en entier avant de
l’installer.
Antes de instalar la unidad, hacerle
mantenimiento o limpiarla, desconecte la
alimentación en el tablero de servicio y cierre
con llave el interruptor del circuito para impedir
la reactivación accidental. De no poder cerrarse
el interruptor con llave, aplíquele al tablero una
etiqueta o dispositivo de advertencia bien
visible.
1. El diseño compacto y adaptable de los
ventiladores de la Serie FG facilita la instalación.
Los ventiladores se despachan totalmente
ensamblados, y se pueden montar a cualquier
ángulo. Vea en la página siguiente los distintos
montajes disponibles.
2. Debido a que esta unidad tiene piezas
rotativas, hay que tomar medidas de precaución a
toda hora durante la instalación, operación y
mantenimiento de la misma.
3. PRECAUCION: “Sólo para Empleo en Ventilación
General. No Usar Como Extractor de Material y
Vapores Peligrosos o Explosivos.”
4. Desempaque la unidad e inspecciónela antes de
los 15 días de recibida. Si presenta daños,
informe al transportista. No opere esta unidad si
presenta daños visibles al conjunto de ventilador o
impulsor.
5. PRECAUCION: “Esta unidad contiene un impulsor
expuesto.No la utilice en sitios de fácil acceso por
personas o animales.”
¡USE PROTECCION PARA LAS MANOS Y CUIDESE DE
CANTOS O BORDES AFILADOS!
6. Hay que instalar rejillas de guarda al alcance
del personal, a menos de (7) pies del sitio de la
obra o donde quiera que hagan falta para
protección.
7. PRECAUCIÓN: La bombilla utilizada en los
modelos fluorescentes no es atenuable.
8. PRECAUCIÓN: Utilice solamente focos
fluorescentes Fantech (modelo PBB14) y focos de
halogeno PAR16 / MR16 GU10 de un max de
50W (modelo PBB50)
9. FAVOR leer este manual por completo antes de
proceder a la instalación.
3
fantech
WARNINGS
DO NOT CONNECT POWER SUPPLY until fan is
completely installed. Make sure electrical service
to the fan is in the locked “OFF” position.
1. All fans are suitable for use with solid-state
speed control. Three phase units must be wired
through a motor contactor.
2. WARNING! TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS -
OBSERVE THE FOLLOWING:
a. Use this unit in the manner intended by the
manufacturer. If you have any questions,
contact your manufacturer’s representative or
contact us directly.
b. CAUTION: Before installation, servicing or
cleaning unit, switch power off at the service
panel and lock the service disconnect to
prevent power from being switched on
accidentally. When the service disconnect
cannot be locked, securely fasten a prominent
warning device, such as tag, to the panel.
c. Installation work and electrical wiring
must be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated construction.
d. Sufficient air is needed for proper
combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety
standards such as those published by the
National Fire Association (NFPA), and the
American Society for Heating, Refrigeration
and Air-Conditioning Engineers (ASHRAE), and
the local code authorities.
e. When cutting or drilling into wall and ceiling,
do not damage electrical wiring and other
hidden utilities.
f. Ducted fans must always be vented to the
outdoors.
g. If this unit is to be installed over a tub or
shower, it must be marked as appropriate for
the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected
branch circuit.
h. NEVER place a switch where it can be
reached from a tub or shower.
3. WARNING! Check voltage at the fan to see if it
corresponds to the motor name plate.
ADVERTISSEMENTS
NE PAS BRANCHER l’électricité jusqu’à ce que le
ventilateur soit complètement installé. Veillez à ce
que le tableau électrique du ventilateur soit
verrouillé (“OFF”).
1. Tous les ventilateurs sont faits pour être
utilisés avec une commande de vitesse. Les
appareils avec trois vitesses doivent être reliés à
un interrupteur et un disjoncteur.
2. AVERTISSEMENTS POUR RÉDUIRE LES
RISQUES D’INCENDIE, DE DECHARGE
ELECTRIQUE OU RISQUE DE BLESSURES. SUIVEZ
LES CONSEILS SUIVANTS:
a. Cet appareil ne doit pas être utilisé pour une
autre fonction que celle prévue par son
fabricant. Si vous avez des questions,
contactez les représentants de vos fabricants
ou contactez-nous directement.
b. ATTENTION: Avant l’installation, le service
ou le nettoyage de l’appareil, fermer l’électri-
cité et fermer à clé le compteur électrique afin
d’éviter que l’électricité ne soit retranchée
accidentellement. Si le compteur ne peut pas
être fermé à clé, attachez au compteur un
dispositif de sécurité comme par exemple une
étiquette.
c. L’installation de l’électricité doit être faite
par une personne qualifiée en accord avec
les codes applicables et les règles pour la
construction anti-feu.
d. La circulation de l’air est nécessaire pour
une bonne combustion et pour l’aspiration des
gazs dans la cheminée afin d’éviter des
refoulements. Suivez le guide de chauffage du
fabriquant ainsi que les règles de sécurités
comme celles qui sont éditées par l’Associa-
tion Nationale des Sapeurs Pompiers (NFPA) et
l ‘Association américaine des Ingénieurs pour le
chauffage et l’air conditionné (ASHRAE) ainsi
que celles des autorités locales.
e. Lorsque vous coupez ou percez le mur et le
plafond faites attention de ne pas endommager
les câbles électriques des autres appareils
utilitaires.
f. Le ventilateur caréné doit toujours être
branché sur l’extérieur.
g. Si l’appareil doit être installé au-dessus
d’une baignoire ou d’une douche, il doit être
signalé comme tel pour son utilisation et
l’installation d’une prise de terre est
nécessaire.
h. NE JAMAIS placer près de la baignoire ou
de la douche un interrupteur à porté de la
main.
3. ATTENTION : Vérifier le voltage afin de voir s’il
correspond à celui indiqué sur la plaque du
moteur.
ADVERTENCIAS
NO CONECTE LA ALIMENTACION hasta tanto el
ventilador quede completamente instalado.
Cerciórese de que el servicio eléctrico al
ventilador quede asegurado en la posición “OFF”
(desactivado).
1. Todos los ventiladores vienen preparados para
controlarse mediante controles de estado sólido.
Las unidades trifásicas tienen que cablearse a
través de un contactor de motores.
2. ADVERTENCIA: PARA REDUCIR EL RIESGO DE
INCENDIO, CONMOCION ELECTRICA O LESIONES
A PERSONAS, OBSERVE LO SIGUIENTE:
a. Sólo utilice esta unidad de la manera
dispuesta por el fabricante. Si tiene cualquier
pregunta, diríjase al representante del
fabricante, o bien a nosotros directamente.
b. PRECAUCION: Antes de la instalación,
mantenimiento o limpieza de la unidad,
desconecte la alimentación en el tablero de
servicio y cierre con llave el interruptor del
circuito para impedir la reactivación accidental.
De no poder cerrarse el interruptor con llave,
aplíquele al tablero una etiqueta o dispositivo
de advertencia bien visible.
c. Los trabajos de instalación y cableado
eléctrico tienen que ser realizados por personal
calificado conforme todos los códigos y normas
del caso, incluso el código de incendio en la
construcción.
d. La debida combustión y extracción de gases
a través de la chimenea de equipos
quemadores de combustibles, requiere de una
cantidad adecuada de aire que impida el
contratiro. Siga las pautas y normas de
seguridad del fabricante, tales como publica la
National Fire Association (NFPA) (Asociación
Nacional de Incendios) y la American Society
for Heating Refrigeration and Air-conditioning
Engineers (ASHRAE), así como las de las
autoridades locales del código.
e. Al cortar o perforar paredes y cielos rasos,
tenga cuidado de no dañar el cableado eléctrico
u otros servicios públicos ocultos.
f. Los ventiladores montados en conductos
siempre deben contar con respiraderos al
exterior.
g. Si esta unidad ha de instalarse por encima
de una bañera o ducha, tiene que venir
marcada como tal par dicha aplicación y
conectarse a un circuito protector interruptor
de circuitos de tierra falla.
h. JAMAS coloque un interruptor al alcance de
una bañera o ducha.
3. ¡ADVERTENCIA! Revise el voltaje entrante al
ventilador para constatar que corresponda al que
indica la placa de fábrica.
4
fantech
Flexible Duct Installation Hints
Fantech strongly recommends the use of flexible insulated duct where
ducting passes through unconditioned space or where noise is a factor.
Check local code requirements before installing. Failure to use insulated
flexible duct could result in excessive condensation buildup within the duct,
and undesirable sound levels within the room.
A minimum of 8' of insulated flexible duct is recommended between
the fan and any inlet grille. Duct should be stretched as tight and straight as
possible. Failure to do so could result in dramatic loss of system
performance. Connect flex duct to the fan with plastic zip ties or duct tape.
Connections should be airtight as possible for maximize performance.
Installating Fan and Bracket
1. Before selecting mounting location for fan, consider the following:
a) Mounting the fan as far as possible from the intake point will assure
quiet operation. A minimum of 8’ of insulated flexible duct is
recommended between exhaust grille and fan.
b) Place fan where it can be easily accessed for service.
2. Attach the mounting bracket to a support beam with wood screws
provided. Fan can be mounted at any point along the duct and at any angle.
Vertical mounting is recommended to reduce condensation in the fan. For
horizontally mounting, either wrap insulation around the fan or drill a 1 1/4"
hole in the bottom of the housing. Add NPT insert and drain tube (purchased
separately) for drainage of condensation .
3. For PB Series fans, if bracket is used to mount fan, refer to illustration 1. If
suspending fan with hanger straps, refer to illustration 2.
4. Connect duct to inlet and outlet of fan using plastic ties or duct tape
(purchased separately). When using insulated flexible duct, the inner vinyl
core should be clamped or taped to the inlet and outlet and the vapor
barrier surrounding the insulation should be duct taped to the fan housing.
Note: Steps 2 & 3 may be reversed.
Fantech recommends insulated flexible duct for all bathroom exhaust
applications.
Electrical Connection
1. Remove the screws securing the terminal box cover located on the fan
motor mounting bracket. All fan motor and capacitor connections are pre-
wired to an electrical terminal strip. A 3/8" romex type cable restraint
connector will be needed to secure the wiring through the knockout on the
side of the terminal box.
2. Bring incoming electrical service through the romex connector and the
fan electrical service opening. Be sure to place the connector nut over the
wiring coming into the terminal box. There are two open ports on the
terminal strip. Using a small regular screwdriver, tighten the neutral (white)
wire of the incoming supply under the open terminal strip port labeled “N”.
Tighten the line (black) wire of the incoming supply under the open terminal
strip port labeled “L” to the ground connection on the terminal block.
3. Secure the romex connector. Secure the incoming supply with the romex
connector. Place the capacitor back into the terminal box. Replace the fan
terminal box cover. All fan motor and capacitor connections have been pre-
wired from the factory. No additional fan wiring is necessary.
Wiring Diagrams
Troubleshooting
If fan fails to operate, please check the following:
1. Consult wiring diagrams (above) to ensure proper connection.
2. Check motor lead wiring, capacitor leads and incoming supply leads to
insure definite contact.
3. If possible, use a meter to test for continuity across the fan motor leads.
In order to do this, the capacitor must be disconnected (do not test the
capacitor - it will not meter continuity). If motor leads show continuity,
consult factory for a replacement capacitor.
Maintenance Instructions
Since fan bearings are sealed and provided with an internal lubricating
material, no additional lubrication is necessary.
Multiple Location Switching Wiring Diagram
With Motor Speed Controller
Without Motor Speed Controller
WARNING
Maximum torque that can be
applied to the terminal block
screws is 0.79 Nm (7 lb-in).
Illustration 1
Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws.
Illustration 2
Fans may be suspended
without special
mounting brackets.
Clamp Fastener
Duct Fan
Spiral duct
Vibration absorbing material
Mounting Bracket & Screw Locations for FG
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB110
• PB110F
• PB110H
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB370-2
• PB110
• PB110F
• PB110H
• PB370-2
5
fantech
Installation of Ceiling Grille Housing With
or Without Light
1. Plan Location of Inlet Grilles
Based on the bathroom layout and fixtures, plan the location of the ceiling
grilles for the most effective ventilation.
2. Securing the Housing to the Ceiling Joists
NEW CONSTRUCTION
Mount housing directly to the ceiling joist using screws and keyhole slots.
Locator tabs on housing should be flush with the bottom edge of the ceiling
joist for correct positioning of the unit once drywall is installed (Figure 1).
OR
Use the hanger bars to suspend the housing between ceiling joists. For
correct positioning, hanger bars should be positioned
3
/
16
" up from the
bottom edge of the ceiling joist on models with 4" duct connection and
15
/
32
" up from bottom edge of joist on models with 6" duct connection. On
models with 4" duct, tighten anti-slide screws to keep hanger bars in place.
(Figure 2).
Note: Hanger bars on units with 4" duct connection can be used on ceiling
joists up to 24" on center. Hanger bars on units with 6" duct connection
span ceiling joists up to 16" on center.
Note: If drywall or ceiling material is thicker than
5
/8" the locator tabs may
be removed to allow the grille collar to be flush with the finished ceiling
material. When ceiling drywall is being installed, cut hole for ceiling grille.
EXISTING CONSTRUCTION OR WHEN DRYWALL IS IN PLACE.
Cut a 6" round hole for the ceiling grille only and install the housing from the
attic (Figure 3). Place the housing against the ceiling joist using the locator
tabs to determine the correct position (Figure 1) or align it using the hanger
bars (Figure 2). Punch out the keyhole knockouts (if using) and the electrical
knockout if needed. To complete installation for Bath Fan models with lights,
continue with steps 3 through 5. For models without lights, skip to steps 4
and 5.
3. Make Electrical Connections to the Ceiling Grille Housing.
Remove the electrical cover inside the steel housing using a screwdriver.
Connect power by following wiring diagram (Figure 5) and following local or
National Electrical Codes. Replace the electrical cover.
4. Connect the Fan to the Ceiling Grille Housing(s).
Install appropriate diameter duct from the fan to the ceiling grille housing.
(Insulated flexible duct is recommended for all Fantech bathroom exhaust
applications for quieter operation.) For dual grille models, install duct between
fan and wye adapter* (included). Then, attach duct to each leg of the wye and
to each ceiling grille housing. Secure duct in place and seal. If using insulated
flexible duct, seal the inner liner to the duct connector then seal the outer shell
over the top of the inner liner. Do not leave the insulation material exposed.
5. Installing the Bulb.
Install the bulb by gently inserting it into the socket in the grille housing.
Install the grille by pushing it firmly into the steel collar until it is shouldered
by the ceiling drywall (Figure 3).
Repeat steps 1 through 5 for each additional ceiling grille housing being
installed.
Figure 1
Postion Locator Tabs
flush with bottom
edge of joist
SCALE 3/10
Figure 2
Anti-slide
locking screw
on models with
4" duct.
Housings with 4"
duct:
3
/16" from
bottom edge of
joist.
Housings with 6"
duct:
15
/32"
Additional steps required when installing a fluorescent model over a tub or
shower (Figure 4)
1. Place ring 1 on on socket legs first.
2. Screw metal shield in place over socket.
3. Add rubber gasket
4. Secure ring 2 to socket. Click indicates a secure installation.
Electrical
Figure 5
Figure 3
Figure 4
Grille
Fluorescent
lamp
Ring 2
Ring 1
Shield
Gasket
Socket
Screw
* For most efficient operation wye adapter should be positioned
the equivalent of three duct diameters away from the fan inlet.
fantech
6
DIMENSIONS
All dimensions are in inches and mm.
Housing Dimensions of 4" duct models Housing Dimensions of 6" duct models
9
11
/
16
" (246mm)
9
9
/16" (243mm)
7
3
/16" (182.5mm)
8
15
/16" (227mm)
5
13
/16" (148mm)
13
/16" (21mm)
5
5
/16" (134mm)
4" (102mm)
5
/16" (8mm)
5
1
/
16
"
(148mm)
9" (230mm)
8" (205mm)
6" (150mm)
17
1
/
4
" (438mm)
7
fantech
Les ventilateurs peuvent être
suspendus sans aucun
supports de montage
spéciaux.
Conseils pour l’installation de tuyaux flexibles
Fantech recommande fortement l'utilisation de tuyaux flexibles isolants dans
les pièces à ventilation non contrôlée, ou pour minimiser le bruit. Consultez
les codes de votre région avant l'installation. Faute d’utiliser les conduits
flexibles isolants pourrait causer une accumulation excessive de
condensation dans le conduit et un niveau de bruit nuisible dans la pièce. Un
minimum de 8 pieds de tuyau flexible isolant est recommandé entre la grille
et le ventilateur. Il devrait être étiré à son maximum et être aussi droit que
possible, sans quoi la performance en serait grandement diminuée. Fixez le
tuyau flexible au ventilateur avec un collier de serrage ou un ruban adhésif en
toile. Le branchement doit être le plus étanche que possible afin de
maximiser le rendement du système.
Planifier l’emplacement du ventilateur
1. Avant de choisir l’emplacement de votre ventilateur, prenez en
considération :
a) Plus loin vous installerez le ventilateur du point d'entrée, moins vous
entendrez du bruit de la pièce que vous ventilez.
b) Assurez-vous que le ventilateur soit accessible.
2. Attachez le support à une poutre du support à l’emplacement choisi à
l'aide des vis fournies. Le support vertical est recommandé pour réduire la
formation de condensation dans le ventilateur. Pour une installation
horizontale, enroulez alors l’isolation autour du ventilateur ou faites un trou
de 1¼ po dans le bas de la boîte (avec une insertion de NPT et une
tuyauterie de vidange) permet à la condensation de s’écouler.
3. Pour les ventilateurs de la sèrie PB on utilise un support pour installer le
ventilateur, se référer à l’illustration 1. Si le ventilateur va être suspendu au
moyen de courroies, voir l’illustration 2.
4. Branchez les tuyaux d'entrée et de sortie à l'aide de colliers de serrage
en plastique ou de ruban adhésif en toile (non inclus). Lorsque vous utilisez
des conduits flexibles isolants, la paroi intérieure en vinyle devrait être fixée
à l'aide d'un collier de serrage ou de ruban adhésif en toile sur la prise
d'entrée et de sortie et la barrière de vapeur entourant l'isolation devrait etre
fixée au boîtier à l'aide de ruban adhésif en toile.
Fantech recommande le conduit flexible isolant pour toutes les applications
d'évacuation pour salles de bains.
NOTE : Les étapes 2 et 3 peuvent être inversées.
Branchement électrique
1. Retirez les vis fixant le couvercle de la boîte de câblage sur le côté du
ventilateur. Tous les fils du moteur du ventilateur sont préalablement
câblés à une bande de branchement électrique. Un connecteur câble
encastré de type «Romex» 15,8 mm sera nécessaire afin de fixer le fil
d’alimentation à la boîte de câblage.
2. Passez les fils d’alimentation à travers le connecteur de câble encastré.
Assurez-vous de placer l’écrou du connecteur au-dessus des fils entrant
dans la boîte de câblage. Il y a deux emplacements libres sur la bande
de branchement. À l’aide d’un tournevis régulier, serrez le fil
d’alimentation blanc sous la vis indiquée « N ». Serrez le fil d’alimentation
noir sous la vis indiquée «L». Puisque le moteur du ventilateur est isolé
dans un boîtier en plastique, la prise de terre n’est pas nécessaire.
3. Fixez le connecteur «Romex». Fixez l’entrée de l’alimentation avec le
connecteur «Romex». Replacez le couvercle de la boîte de câblage. Tous
les fils du moteur ayant été préalablement câblés à l’usine, aucun autre
raccordement est nécessaire.
Diagramme de branchement
Dépannage
Si le ventilateur ne fonctionne pas, vérifiez ce qui suit :
1. Consultez les diagrammes de câblage (voir ci-dessous) pour vous
assurer que la connexion est appropriée.
2. Contrôlez le fil de sortie du moteur, les fils de sortie du condensateur et
l’alimentation électrique pour vous assurer d’un bon contact.
3. Si possible, utilisez un appareil de mesure pour déterminer la continuité
àtravers les fils de sortie du moteur du ventilateur. Pour faire ceci, le
condensateur doit être débranché (ne pas tester le condensateur - il ne
montrera pas la continuité). Si les fils de sortie du moteur montrent la
continuité, consultez l’usine pour un condensateur de rechange.
Instructions pour l'entretien
Puisque les roulements du ventilateur sont scellés et équipés d’un matériel
lubrifiant interne, aucune lubrification supplémentaire n’est nécessaire.
Diagramme de branchement pour plusieurs pièces
Avec contrôle de vitesse du moteur
Sans contrôle de vitesse du moteur
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Mise à la terre Vert/Jaune
Avertissement
Le couple maximal qui peut
être appliqué aux vis du bornier
est de 0.79 Nm (7 lb-in).
Illustration 1
Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws.
Illustration 2
Adapteur pour attaches
Ventilateur
Conduit en spirale
Matériel absorbant le vibration
Placement des vis de montage et du crochet
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB110
• PB110F
• PB110H
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB370-2
• PB110
• PB110F
• PB110H
• PB370-2
8
fantech
Installation du boîtier avec ou sans éclairage
1. Planifiez l'endroit pour la grille
D'après votre salle de bain et ses installations, planifiez l'endroit où vous
installerez vos grilles de plafond pour une ventilation efficace.
2. Fixez le boîtier à la poutrelle du plafond.
NOUVELLE CONSTRUCTION
Fixez le boîtier directement sur la poutre du plafond avec les vis. Les
languettes sur le boîtier devraient être au même niveau que le côté inférieur
de la poutrelle du plafond (Figure 1).
OU
Utilisez les barres de suspension pour fixer le boîtier à la poutrelle du
plafond. Pour être exacte, les barres de suspensions doivent être à 3¼16
po au-dessus du côté inférieur de la poutrelle du plafond pour les modèles à
collets de 4 po et 15¼32 po pour les modèles de 6 po. Sur les modèles à
conduits de 4 po serrez les vis anti-dérapantes pour sécuriser les barres de
suspension en place (Figure 2).
Note: Les barres de suspension des appareils à collets de 4 po peuvent être
utilisées sur les poutrelles de plafond jusqu'à 24 po du centre. Les barres de
suspension pour les appareils à conduits de 6 po peuvent aller jusqu'à 16 po
du centre.
Note: Si le gypse ou le matériel de plafond est plus épais que 5¼8 po, les
languettes de position peuvent être enlevées pour permettre au collier de la
grille d’être au même niveau que le plafond fini. Lorsque le gypse est posée
au plafond, pratiquez une ouverture pour accomoder la grille. Dégagez
l’ouverture pour les fils d’alimentation de la boîte de câblage.
CONSTRUCTION EXISTANTE OU GYPSE EN PLACE.
Percez un trou de 6 po pour la grille de plafond seulement et installer le
boîtier dans le grenier. Placez le boîtier sur la poutrelle de plafond en
utilisant les locator tabs pour déterminer l'emplacement exacte (Figure 1) ou
enligner en utilisant les barres de suspension (Figure 2). Percez un trou si
nécessaire. Pour compléter l'installation des ventilateurs pour salle de bains
avec éclairage, suivez les étapes 3 à 5. Pour les modèles sans éclairage,
passez directement aux étapes 4 et 5.
3. Faites la connexion électrique au boîtier de la grille au plafond. En
utilisant un tournevis, enlevez le couvercle électrique à l’intérieur du boîtier
en métal. Connectez le courant en suivant le diagramme de branchement
(Figure 5) et en suivant les codes électriques locaux ou les codes électriques
nationaux. Remettez le couvercle électrique.
4. Raccordement du ventilateur du boîtier. Installez le conduit de 4 po ou de
6 po du ventilateur au boîtier de la grille au plafond. (Les conduits flexibles
isolants recommandés par Fantech pour toutes applications d’évacuation
pour salle de bains vous donneront un rendement plus silencieux). Pour les
modèles à grilles jumelles, montez les conduits entre le ventilateur et
l’adapteur « wye » (inclus), puis reliez les conduits à chaque sortie du « wye »
et à chaque boîtier des grilles. Attachez les conduits en place, puis scellez.
Si vous utilisez un tuyau flexible isolant, scellez la couche intérieure au
connecteur de conduit puis scellez la couche extérieure couvrant la couche
intérieure. Ne laissez pas le matériel isolant exposé.
5. Installation de l'ampoule. Procédez en insérant doucement l’ampoule dans la
douille située dans le boîtier de la grille. Posez la grille en la poussant fermement le
collier jusqu’à ce que la grillle soit en contact ferme avec le plafond. (Figure 3).
Répétez les étapes 1 à 6 pour chaque boîtier de grille pour plafond additionnel à
installer.
Figure 1
SCALE 3/10
Figure 2
Vis anti-dérapante
sur modèles à
conduits de
4 po.
Boîtier avec un
conduit de 4 po :
3
¼16 po du dessous
de la poutrelle.
Boîtiers avec 6 po :
15
/32 po
Figure 3
Figure 4
Grille
Ampoule
Fluorescente
* Pour un fonctionnement plus efficace, l’adapteur « wye » devrait être positionné à une
distance égale à trois fois le diamètre du conduit de l'entrée du ventilateur.
Étapes additionnelles lors de l’installation d’un modèle fluorescent
au-dessus d’une baignoire ou d’une douche (Figure 4).
1. Placer lanneau « 1 » sur la douille, en commençant par les pattes.
2. Visser le panneau en métal sur la douille.
3. Ajouter le joint en caoutchouc.
4. Bien attacher l’anneau « 2 » sur la douille. Le clic indique une
installation sécurisée.
Postionnez les languettes de position
à la poutrelle du plafond
Anneau 2
Anneau 2
Panneau
Joint
Douille
Vis
Figure 5
Électrique
9
fantech
DIMENSIONS
Toutes les dimensions sont en pouces.
Dimension du boîtier des modèles à conduit de 4 po Dimension du boîtier des modèles à conduit de 6 po
9
11
/
16
" (246mm)
9
9
/16" (243mm)
7
3
/16" (182.5mm)
8
15
/16" (227mm)
5
13
/16" (148mm)
13
/16" (21mm)
5
5
/16" (134mm)
4" (102mm)
5
/16" (8mm)
5
1
/
16
"
(148mm)
9" (230mm)
8" (205mm)
6" (150mm)
10
fantech
(Negro)
(Azul)
(Marrón)
(Marrón)
Condensador
Conmutación de posición múltiple
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
(Negro)
(Azul)
(Marrón)
(Marrón)
Condensador
Conmutación de posición múltiple
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
(Negro)
(Azul)
(Marrón)
(Marrón)
Condensador
Conmutación de posición múltiple
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
Tierra (Verde/Amarillo)
Consulte los requerimientos del código local antes de la instalación. Para
lograr la instalación más silenciosa posible, Fantech recomienda un mínimo
de 8 pies de conducto flexible aislado entre cualquier rejilla de admisión y el
ventilador. Al montar un conducto de tipo flexible, el mismo se debe instalar
lo más apretado y recto posible. De lo contrario, el sistema podría sufrir una
importante pérdida de rendimiento. El conducto flexible se debe conectar al
ventilador con abrazaderas de plástico tipo CB o con cinta para conductos.
Todas las conexiones deben quedar lo más herméticas posible para lograr un
máximo rendimiento.
Conexión eléctrica
1. Quite los tornillos de montaje de la tapa de la caja de conexiones en el
costado del ventilador. Todas las conexiones del motor del ventilador están
precableadas a una regleta eléctrica. Se necesitará un conector de fijación
de cables tipo romex de 3/8" para sujetar el cableado a través del agujero
ciego provisto en el costado de la caja de conexiones.
2. Pase la alimentación eléctrica a través del conector romex y el agujero
ciego del ventilador. Tenga cuidado de colocar la tuerca del conector encima
del cableado que entra a la caja de conexiones. En la regleta de conexiones
hay dos lumbreras abiertas. Con un pequeño destornillador estándar, apriete
el cable neutro (color blanco) de la alimentación eléctrica debajo de la
lumbrera marcada “N” en la regleta. Apriete el hilo de línea (negro) de la
alimentación eléctrica debajo de la lumbrera marcada “L”. Dado que el motor
del ventilador está aislado por su carcasa de plástico, no es necesario
conectarlo a tierra.
3. Asegure el conector romex. Asegure la alimentación entrante con el
conector romex. Vuelva a colocar la tapa de la caja de conexiones del
ventilador. Todas las conexiones del motor del ventilador y del capacitor
vienen precableadas de fábrica. No hace falta ningún cableado adicional para
el ventilador.
Instalación del extractor en la pared exterior
1. Antes de elegir la posición para la instalación del ventilador, considere los
puntos siguientes:
a) Instalar el ventilador lo más alejado posible al punto de admisión garantiza
una operación silenciosa. Se recomienda un mínimo de ducto flexible aislado
de 8 entre la rejilla de escape y el ventilador.
b) Coloque el ventilador en un lugar de fácil acceso para darle servicio.
2. Fije el soporte de instalación a una vigueta de soporte con los tornillos
para madera incluidos. Es posible instalar el ventilador en cualquier punto a
lo largo del ducto y en cualquier ángulo. Se recomienda la instalación vertical
para reducir la condensación en el ventilador. Para instalaciones horizontales,
enrolle aislante alrededor del ventilador o perfore un agujero de 1¼" en la
base de la caja. Agregue el inserto NPT y la manguera de drenaje (comprada
por separado) para el drenaje de la condensación.
3. Para los ventiladores Modelo FG, si han de montarse en un soporte,
refiérase a la Ilustración 1. Si ha de colgarse un ventilador con tirantes,
refiérase a la Ilustración 2.
4. Conecte el conducto a la entrada y salida del ventilador con abrazaderas
de plástico tipo CB [de terceros] o con cinta especial para conductos.
Cuando se usen conductos flexibles con aislamiento, se recomienda que el
núcleo de vinilo se sujete con abrazadera o cinta a la entrada y a la salida y
que la barrera contra vapor que rodea el material aislante se fije con cinta
para conductos a la caja del ventilador.
Fantech recomienda el uso de conductos flexibles y aislados para todas las
aplicaciones de escape en el baño.
NOTA: Se puede invertir el orden de los pasos 2 y 3.
Diagramas de cableado
Los ventiladores se pueden
colgar sin necesidad de
soportes especiales.
Ilustración
1
Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws.
Ilustración
2
Tornillo de Abrazadera
Ventilador en Conducto
Conducto
Material amotiguador en Espiral
Soporte Montura Y Tornillo Localización
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB110
• PB110F
• PB110H
• PB190
• PB270-2
• PB270F-2
• PB270H-2
• PB270FV-2
• PB270HV-2
• PB370-2
• PB110
• PB110F
• PB110H
• PB370-2
Sugerencias para la instalación del conducto flexible
Fantech recomienda firmemente el uso de ducto aislado flexible cuando los
ductos atraviesan espacios no acondicionados o donde el ruido sea un factor
a considerar.
Diagrama de cableado para conmutación desde varios puntos
Sin controlador de velocidad de motor
Con controlador de velocidad de motor
Advertencia
El par máximo que se puede
aplicar a los tornillos de la
caja de bornes es de 0.79
Nm (7 lb-in).
11
fantech
Instalación de la caja de rejilla de techo con o sin luz
1. Planee la ubicación de las rejillas de admisión.
Con base en el diseño y el mobiliario del baño, planee la ubicación de las
rejillas del techo para obtener la ventilación más efectiva.
2. Fije la caja a las viguetas del techo.
CONSTRUCCIÓN NUEVA
Fije la caja directamente en la vigueta del techo con tornillos y las ranuras
de alineación. Las pestañas de ubicación en la caja deben estar a nivel con el
borde inferior de la vigueta del techo para la correcta ubicación de la unidad
una vez instalada la tablarroca. (Figura 1)
O
Utilice las barras de soporte para sujetar la caja entre las viguetas del
techo. Para su colocación correcta, las barras de soporte deben colocarse a
13/16" arriba del borde inferior de la vigueta del techo en los modelos con
conexión de ducto de 4" y 15/32" arriba del borde inferior de la vigueta en
los modelos con conexión con ducto de 6”. En los modelos con ducto de 4",
apriete los tornillos antideslizantes para mantener las barras de soporte en
su sitio. (Figura 2).
Nota: Las barras de soporte en las unidades con conexión de ducto de 4"
pueden emplearse en viguetas de techo de hasta 24" en el centro. Las
barras de soporte en las unidades con conexión de ducto de 6" abarcan las
viguetas del techo hasta una distancia de 16" desde el centro.
Nota: Si el grosor del panel de yeso o del material del techo es de más de
5/8" ahora puede retirar las pestañas guías. Durante la instalación de la
tablarroca, corte un hueco para la rejilla del techo.
CONSTRUCCIÓN EXISTENTE O CUANDO LA TABLARROCA ESTÁ EN SU
SITIO
Corte una orificio redondo de 6” sólo para la rejilla e instale la caja desde el
altillo. (Figura 3)
Coloque la caja contra la vigueta del techo. Para completar la instalación en
los modelos de ventilador para baño con luz, continúe con los pasos del
3 al 5. Para los modelos sin luces, vaya a los pasos 4 y 5.
Perfore los agujeros ciegos (si se van a usar) y el que corresponda al cable
eléctrico si es necesario.
Siga con los pasos 3 a 5 para continuar con la instalación de los modelos de
ventiladores para baño Premium con luces. De lo contrario, siga a los pasos
4 y 5 para completar la instalación de los modelos sin luces.
Análisis de fallas
Si el ventilador deja de funcionar, revise lo siguiente:
1. Consulte los diagramas eléctricos (a la derecha) para asegurar que las
conexiones se hagan correctamente.
2. Revise el cableado del motor, del capacitor y de la alimentación eléctrica
para asegurar el debido contacto.
3. Si es posible, use un comprobador para verificar la continuidad entre los
hilos del motor del ventilador. Para ello, se debe desconectar el capacitor.
(No pruebe el capacitor, ya que no tiene continuidad.) Si los hilos del motor
muestran continuidad, solicite a la fábrica un capacitor de repuesto.
Instrucciones de mantenimiento
Puesto que los rodamientos del ventilador están sellados y provistos de
lubricante interno, no es necesario aplicarles lubricante adicional.
3. Efectúe las conexiones eléctricas a la caja de la rejilla de techo.
Con un destornillador, retire la tapa eléctrica del interior del gabinete de
acero. Conecte la alimentación conforme a los diagramas de cableado
(Figura 5) y cumpliendo con los códigos locales o nacionales sobre
instalaciones eléctricas. Vuelva a colocar la tapa eléctrica.
4. Conecte el ventilador a la caja de la rejilla de techo. Instale el conducto de
4" o 6" desde el ventilador hasta la caja de la rejilla. El uso de conducto
flexible con aislamiento (recomendado para todas las aplicaciones de
ventilación de baños de Fantech) producirá un funcionamiento más silencioso.
Sujete el conducto en su lugar y séllelo. Si se usa conducto flexible con
aislamiento, selle el forro interior al conector del conducto, a continuación
selle la carcasa exterior por sobre el forro interior. No deje al descubierto el
material aislante.
5. Instalación de la bombilla. Instale la bombilla introduciéndola con cuidado
en el portabombillas dentro del gabinete de acero. Para instalar la rejilla
empújela firmemente hacia el collarín de acero hasta quedar a ras del panel
de yeso del techo (Figura 3).
Repita los pasos del 1 al 5 para cada caja de rejilla de techo que se instale.
* Para obtener una operación más eficiente el adaptador en “Y” debe colocarse a una
distancia equivalente a tres diámetros del ducto del ventilador de admisión.
Pasos adicionales necesarios cuando se instala un modelo fluorescente
encima de una bañera o ducha (Figura 4)
1. Coloque el aro 1 sobre el casquillo, con las patas primero.
2. Atornille la placa protectora de metal sobre el casquillo.
3. Instale la guarnición de goma.
4. Fije el aro 2 en el casquillo. El chasquido indica la instalación segura.
12
fantech
Tierra
Figure 1
Coloque las pestañas guías
al ras con el borde inferior
de la vigueta.
SCALE 3/10
Figure 2
Tornillo
antideslizante de
seguridad en
modelos con
ducto de 4
"
.
Cajas con ducto de
4
"
: A
3
/16"
desde la
base inferior de la
vigueta. Cajas con
ducto de 6”:
15
/32"
Eléctrico
Figure 5
Figure 3
Figure 4
Grille
Bombilla
Fluorescente
Socket
DIMENSIONES
Todas las dimensiones son en pulgada.
Dimensiones de la caja de los modelos de conductos de 4"
Dimensiones de la caja de los modelos de conductos de 6"
9
11
/
16
" (246mm)
9
9
/16" (243mm)
7
3
/16" (182.5mm)
8
15
/16" (227mm)
5
13
/16" (148mm)
13
/16" (21mm)
5
5
/16" (134mm)
4" (102mm)
5
/16" (8mm)
5
1
/
16
"
(148mm)
9" (230mm)
8" (205mm)
6" (150mm)
Todas las dimensiones son en pulgada.
Aro 2
Aro 1
Planca
Guarnición
Casquillo
Tornillo
13
fantech
7 Year Warranty
This warranty supersedes all prior warranties
DURING ENTIRE WARRANTY PERIOD:
Fantech will repair or replace any part which has a factory defect in
workmanship or material. Product may need to be returned to the
Fantech factory, together with a copy of the bill of sale and identified
with RMA number.
FOR FACTORY RETURN YOU MUST:
Have a Return Materials Authorization (RMA) number. This may be
obtained by calling Fantech either in the USA at 1.800.747.1762 or
in CANADA at 1.800.565.3548. Please have bill of sale available.
The RMA number must be clearly written on the outside of the
carton, or the carton will be refused.
All parts and/or product will be repaired/replaced and shipped back to
buyer; no credit will be issued.
OR
The Distributor may place an order for the warranty part and/or product
and is invoiced. The Distributor will receive a credit equal to the invoice
only after product is returned prepaid and verified to be defective.
FANTECH WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT
WITHOUT CHARGE PRIOR TO INSPECTION FOR A DEFECT.
REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE
INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED
MATERIAL. DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD
NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO THE
END USER, AS CREDIT TO DISTRIBUTOR’S ACCOUNT WILL BE
PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY
FANTECH.
THE FOLLOWING WARRANTIES DO NOT APPLY:
Damages from shipping, either concealed or visible. Claim must be
filed with freight company.
• Damages resulting from improper wiring or installation.
Damages or failure caused by acts of God, or resulting from improper
consumer procedures, such as:
1. Improper maintenance
2. Misuse, abuse, abnormal use, or accident, and
3. Incorrect electrical voltage or current.
Removal or any alteration made on the Fantech label control number
or date of manufacture.
Any other warranty, expressed, implied or written, and to any
consequential or incidental damages, loss or property, revenues, or
profit, or costs of removal, installation or reinstallation, for any breach
of warranty.
WARRANTY VALIDATION
• The user must keep a copy of the bill of sale to verify purchase date.
These warranties give you specific legal rights, and are subject to an
applicable consumer protection legislation. You may have additional
rights which vary from state to state.
This warranty does not apply to any Fantech product or part which has
failed as a result of faulty installation or abuse, incorrect electrical
connections or alterations made by others, or use under abnormal
operating conditions or misapplication of the product or parts. We will
not approve for payment any repair not made by us or our authorized
agent without prior written consent. The foregoing shall constitute our
sole and exclusive warranty and our sole exclusive liability, and is in lieu
of any other warranties, whether written, oral, implied or statutory.
There are no warranties which extend beyond the description on the
page hereof. In no event, whether as a result of breach of contract, or
warranty or alleged negligence, defect incorrect advice or other causes,
shall Fantech be liable for special or consequential damages, including,
but not limited to, loss of profits or revenue, loss of use of equipment or
any other associated equipment, cost of capital, cost of substitute
equipment, facilities or services, downtime costs, or claims of
customers of purchase for such damages. Fantech neither assumes or
authorizes any person to assume for it any other liability in connection
with the sale of product(s) or part(s). Some jurisdictions do not allow the
exclusion or limitation of incidental or consequential damages so the
above limitations and exclusions may not apply to you.
Limitation of Warranty and Liability
Warning
Fantech products are designed and manufactured to provide reliable
performance, but they are not guaranteed to be 100% free from
defects. Even reliable products will experience occasional failures and
this possibility should be recognized by the user. If these products are
used in a life support ventilation system where failure could result in loss
or injury, the user should provide adequate backup ventilation,
supplementary natural ventilation, failure alarm system, or acknowledge
willingness to accept the risk of such loss or injury.
WARRANTY
14
fantech
Garantie de 7 ans
Cette garantie remplace toutes les garanties précédentes.
Cette garantie ne s’applique à aucun produit de Fantech ou à aucune
pièce détachée dont la défectuosité relève d’une erreur d’installation ou
d’abus ou de mauvaise installation électrique ou dut à des modifications
extérieures ou utilisées dans des conditions anormales ou encore une
mauvaise installation du produit ou des pièces détachées. Nous
n’approuverons aucun remboursement pour des réparations qui ne sont
pas effectuées par un agent américain ou un agent autorisé sans un
accord écrit. Ce dernier constituera notre seule et exclusive garantie et
notre seule exclusive responsabilité et tient lieu de toute autre garantie
ou bien écrite ou orale implicite ou statuaire. Aucune garantie ne
s’appliquera au-delà des descriptions faites de la page ci-dessus. En
aucun cas, que ce soit pour une rupture de contrat ou de garanties ou
des dommages dut à la négligence ou a des conseils incorrects ou
autres causes, Fantech ne pourra être tenu pour responsable des
dommages particuliers ou consécutifs, incluant mais pas limités aux
pertes et profits ou bénéfices perte de matériel ou autres matériels
associés. Coût du capital, coût des équipements de remplacement,
matériels ou services, coût de temps d’arrêt ou les réclamations des
clients pour de tels dommages. Fantech ne délègue ou autorise aucune
personne d’assumer sa responsabilité sur la vente du produit ou des
pièces détachées. Certaines juridictions ne permettent pas l’exclusion de
la limitation des dommages accidentels ou consécutifs ainsi ces
limitations ci-dessus et les exclusions ne s’appliquent pas à vous.
Limites de garanties et de responsabilités
Avertissement
Les produits de Fantech sont conçus et fabriqués pour produire des
performances fiables, mais il n’y a aucune garantie qu’ils soient 100%
sans défaut. Les plus produits les plus fiables ont occasionnellement des
défectuosités et cette possibilité devraient être reconnu par les usagers.
Si ces produits sont utilisés comme une source de ventilation ou leur
panne risque de mettre en danger des vies humaines ou entraîner des
blessures, les usagers devront avoir une source de ventilation de
secours en addition à une ventilation naturelle, le défaut de système
d’alarme ou la connaissance de ces conditions entraînent sa
responsabilité envers de telles pertes ou blessures.
DURANT TOUTE LA PÉRIODE DE GARANTIE:
Fantech s'engage à réparer ou à remplacer toute pièce présentant un
défaut d'usine en matière de qualité d'exécution ou de matériau. Il sera
peut être nécessaire de retourner le produit à l'usine Fantech,
accompagné d'une copie du contrat de vente et du numéro d'autorisation
de retour.
POUR RETOURNER UN PRODUIT À L'USINE, VOUS DEVEZ:
Obtenir un numéro d'autorisation de retour; pour ce faire,
communiquer avec Fantech aux États-Unis au numéro
1.800.747.1762, ou au Canada, au numéro 1.800.565.3548.
Veuillez avoir votre contrat de vente à portée de la main.
S'assurer que le numéro d'autorisation de retour est lisible sur
l'extérieur de la boîte, sinon la boîte sera refusée.
Toutes les pièces et/ou le produit seront réparés ou remplacés puis
retournés à l'acheteur. Aucun crédit ne sera accordé.
OU
Le Distributeur peut commander une pièce ou un produit couvert par la
garantie; la facture lui sera envoyée. Le distributeur ne sera crédité du
montant de sa facture qu'après que le produit a été retourné port payé
et qu'il a été trouvé défectueux.
LES TERMES DE LA GARANTIE DE Fantech NE PRÉVOIENT PAS DE
REMPLACEMENT SANS FRAIS AVANT QUE LA PIÈCE OU LE PRODUIT
DÉFECTUEUX AIT ÉTÉ INSPECTÉ. LES PRODUITS OU PIÈCES
REMPLACÉS AVANT L'INSPECTION DE LA DÉFECTUOSITÉ SERONT
FACTURÉS ET LE MONTANT DU CRÉDIT EST FONCTION DE
L'INSPECTION DE LA PIÈCE OU DU PRODUIT RETOURNÉ. LE
DISTRIBUTEUR NE DOIT PAS REMPLACER SANS FRAIS POUR
L'UTILISATEUR FINAL L'ÉQUIPEMENT DÉFECTUEUX RETOURNÉ PAR
L'UTILISATEUR FINAL, CAR LE COMPTE DU DISTRIBUTEUR NE SERA
CRÉDITÉ QU'APRÈS L'INSPECTION ET LA VÉRIFICATION PAR FANTECH
DE LA DÉFECTUOSITÉ.
LES GARANTIES NE S'APPLIQUENT PAS DANS LES CAS SUIVANTS:
Dommages dus au transport (dissimulés ou visibles). Les
réclamations doivent être faites à la compagnie de fret.
• Dommages dus au mauvais câblage ou à l'installation inappropriée.
Dommages ou défectuosité causés par une calamité naturelle ou
résultant d'une procédure irrégulière de l'acheteur, notamment :
1. Entretien irrégulier
2. Mauvais usage, usage abusif, usage anormal ou accident
3. Tension ou courant électrique incorrect
Enlèvement ou toute modification du numéro de contrôle ou de la date
de fabrication de l'étiquette Fantech
Toute autre garantie expresse, écrite ou implicite, pour les dommages
accidentels ou indirects, perte de biens, de recettes, manque à
gagner ou coûts relatifs à la dépose, à l'installation ou à la
réinstallation, en cas de violation de garantie.
CERTIFICATION DE LA GARANTIE:
• L'utilisateur doit conserver une copie du contrat de vente pour
confirmer la date d'achat.
Les présentes garanties vous donnent des droits spécifiques reconnus
par la loi et sont régies par les lois sur la protection du
consommateur appropriées. Il est possible que différents états offrent
d'autres droits.
GARANTIE
15
fantech
Garantia de 7 Años
Esta garantia de sin efecto cualquier otra garantia anterior
DURANTE EL PERÍODO INTEGRO DE LA GARANTÍA:
Fantech reparará o reemplazará toda parte que presente un defecto en
el material o en la mano de obra. Es posible que el producto deba ser
devuelto a la fabrica Fantech, juntamente con una copia de la constancia
de compraventa e identificado con el número de RMA.
PARA DEVOLUCIÓN A FÁBRICA USTED DEBE:
Tener un número de Autorización de Devolución de Material (RMA).
Esto se puede obtener llamando a Fantech ya sea en los Estados
Unidos al 1.800.747.1762
• en Canadá al 1.800.565.3548. Tenga a mano la constancia de
compraventa.
El número de RMA deberá estar claramente escrito en la parte
exterior de la caja, de lo contrario la caja será rechazada.
Todas las partes y/o el producto serán reparados/reemplazados y
devueltos al comprador; no se otorgará crédito.
O BIEN
El Distribuidor puede colocar una orden por la parte y/o producto en
garantía y facturarla/o. El Distribuidor recibirá un crédito igual a la
factura sólo después de que se haya devuelto el producto con pago
previo y con verificación de defecto.
LAS CONDICIONES DE LA GARANTÍA DE FANTECH NO CONTEMPLAN
EL REEMPLAZO SIN CARGO ANTES DE REALIZAR LA INSPECCIÓN
PARA DETECTAR DEFECTOS. LOS REEMPLAZOS EMITIDOS ANTES DE
INSPECCIONAR POR DEFECTOS SON FACTURADOS, Y EL CRÉDITO
ESTÁ A LA ESPERA DE INSPECCIÓN DEL MATERIAL DEVUELTO. EL
MATERIAL DEFECTUOSO DEVUELTO POR LOS USUARIOS FINALES NO
DEBERÁ SER REEMPLAZADO POR EL DISTRIBUIDOR SIN CARGO PARA
EL USUARIO FINAL, YA QUE EL CRÉDITO DE LA CUENTA DEL
DISTRIBUIDOR ESTARÁ A LA ESPERA DE INSPECCIÓN Y VERIFICACIÓN
DEL DEFECTO REAL POR FANTECH.
LAS SIGUIENTES GARANTÍAS NO SE APLICAN:
Daños durante el envío, ya sean encubiertos o visibles. Se deberá
presentar el reclamo a la compañía transportadora.
Daños ocasionados por cableado o instalación indebidos.
Daños o fallas causados por hechos fortuitos, u ocasionados por
procedimientos impropios por parte del usuario, tales como:
1. Mantenimiento indebido
2. Uso indebido, abuso, uso anormal o accidente y
3. Tensión o corriente eléctrica incorrecta.
Remoción o modificación realizada al número de control del rótulo de
Fantech o de la fecha de fabricación.
Toda otra garantía, expresa, implícita o escrita, daños y perjuicios,
pérdida de propiedad, de ingresos, o de beneficios, o costo de
remoción, instalación o reinstalación por incumplimiento de la
garantía.
VALIDACIÓN DE LA GARANTÍA
El usuario debe conservar una copia de la constancia de compraventa
para verificar la fecha de compra.
Estas garantías le otorgan derechos legales específicos, y están
sujetas a una legislación aplicable para protección del consumidor.
Usted puede tener derechos adicionales que varían de estado en
estado.
Esta garantía no cubre ningún producto o pieza de Fantech que haya
fallado por mala instalación, abuso, conexión eléctrica incorrecta o por
alteraciones hechas por terceros, o por utilización bajo condiciones
anormales de operación, o por aplicación incorrecta del producto o de
las piezas. Nosotros no aprobamos el pago de ninguna reparación que
no se haya realizado por nosotros o por nuestro agente autorizado previo
consentimiento por escrito. Lo que antecede constituirá nuestra única y
exclusiva garantía y nuestra única y exclusiva responsabilidad; y obra en
lugar de cualquier otra garantía, ya sea escrita, verbal, tácita o
estatutaria. No hay ninguna garantía que vaya más allá de lo que está
descrito en esta página. Bajo ninguna circunstancia responderá Fantech,
ya sea por incumplimiento de contrato o garantía ni por alegada
negligencia, defecto, consejos incorrectos u otra causa, por daños
especiales o consiguientes, incluso, pero no de manera única, pérdida de
ganancias o ingresos, equipo cesante o cualquier otra pérdida relativa a
equipos asociados; el costo del capital, costo de equipos, instalaciones o
servicios sustitutos, tiempo ocioso o reclamos de clientes por compras
incurridas por tales daños. Fantech ni asume ni autoriza a ninguna
persona a que asuma a su nombre ninguna otra responsabilidad relativa
a la venta de productos o piezas. Debido a que algunos distritos
jurisdiccionales no permiten la exclusión o limitación por daños
incidentales o consiguientes, puede que las limitaciones y limitaciones
antes descritas no lo afe cten a Ud.
Limitacion de Garantia y Responsabilidad Civil
Advertencia
Aunque los productos de Fantech están diseñados y son fabricados para
un rendimiento seguro, no garantizamos que estén libres de defectos al
100%. Hasta productos confiables a veces fallan; y el usuario debe
reconocer esta posibilidad. Si estos productos se utilizan en un sistema
de ventilación vital en donde una falla pudiera dar lugar a pérdidas o
lesiones, el usuario debe disponer de una ventilación adecuada de
reserva, ventilación natural suplemental, sistema de alarma de fallas, o
expresar su voluntad de aceptar el riesgo de tales pérdidas o lesiones.
GARANTIA
fantech
Fantech reserves the right to make technical changes.
For updated documentation please refer to www.fantech.net
Fantech®
Fantech se réserve le droit de faire des changements
techniques. Pour de la documentation à jour, s'il vous plaît se
référer au www.fantech.net
Fantech se reserva el derecho de hacer modicaciones
técnicas en cualquier momento. Para obtener la documen-
tación actualizada, por favor consulte www.fantech.net

Transcripción de documentos

Installation and Maintenance Manual Manuel pour l'Installation et l'Entretien Manual de Instalación y Mantenimiento Item #: 412889 Rev Date: 080113 PB Series Premium Bath Fans (single grille unit 4" duct PB110*, PB110F, PB110H; single and dual grille units 6" duct PB190*, PB270-2*, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2) Ventilareurs pour salle de bains premium (grille simple conduit de 4 po PB110*, PB110F, PB110H; grille simple et double conduit de 6 po PB190*, PB270-2, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2) Ventiladores Para Baño Premium (unidades de Reja Solas 4" conducto PB110*, PB110F, PB110H, unidades de reja solas y duales 6" Conducto PB190*, PB270-2, PB270F-2, PB270H-2, PB370-2*, PB370FV-2, PB370HV-2) * United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 • Fax: 800.487.9915 Canada 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 800.565.3548 • Fax: 877.747.8116 * The following models earned the ENERGY STAR® by meeting strict fficiency guidelines set by Natural Resources Canada and the US EPA. fantech 2 Note Warning / Important note Information Technical information Practical tip Avant l’installation, le service ou le nettoyage, coupez l’électricité au compteur électrique et fermez-le à clé afin d’éviter que l’électricité ne soit retranchée accidentellement. Quand le tableau de contrôle ne peut pas être fermer à clé, afficher un dispositif d’avertissement bien en vue, comme une étiquette par exemple placée sur le tableau électrique. Antes de instalar la unidad, hacerle mantenimiento o limpiarla, desconecte la alimentación en el tablero de servicio y cierre con llave el interruptor del circuito para impedir la reactivación accidental. De no poder cerrarse el interruptor con llave, aplíquele al tablero una etiqueta o dispositivo de advertencia bien visible. 1. The compactness and adaptability of the FG Series fans permit easy installation. The fans are shipped fully assembled and can be mounted at any angle. For various mounting, see figures on the following page. 1. La compacité et l’adaptabilité des ventilateurs FG permettent une installation facile. Les ventilateurs sont envoyés complètement assemblés et peuvent être montés sur N’importe quel angle. Pour les montages différents veuillez voir les pages suivantes. 1. El diseño compacto y adaptable de los ventiladores de la Serie FG facilita la instalación. Los ventiladores se despachan totalmente ensamblados, y se pueden montar a cualquier ángulo. Vea en la página siguiente los distintos montajes disponibles. 2. Because this unit has rotating parts, safety precautions should be exercised during all phases of installation, operation and maintenance. 2. Cet appareil contient des parties rotatives, des mesures de sécurités doivent être observées lors de l’installation et l’entretien. 3. CAUTION: “For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Material and Vapors.” 3. PRECAUTION: A utiliser strictement pour une ventilation normale. A NE PAS UTILISER POUR évacuer des vapeurs de matériaux dangereux ou explosifs. Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnect to prevent power from being switched on accidentally. When the service disconnect cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 4. Remove unit from package and inspect within 15 days after receipt. If damaged, report damage to carrier. Do Not operate this unit with visible damage to the blower or impeller assembly. 5. CAUTION: “This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.” WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES! 6. Screen guards must be installed within reach of personnel, within (7) feet of the working area, or when advisable for safety. 7. CAUTION: Bulb used in fluorescent models not dimmable. 8. CAUTION: Use only Fantech Fluorescent bulb (model PBB14) and PAR16 / MR16 GU10 50W max. halogen bulbs (model PBB50). 9. PLEASE read the entire manual before installing. fantech 4. Retirer l’appareil de son emballage et inspectez-le dans les 15 jours qui suivent sa réception. S’il est endommagé, rapporter les dommages à l’envoyeur. Ne Pas utilisez cet appareil avec un dommage apparent sur le souffleur ou le système de ventilation. 5. PRECAUTION: “Cet appareil a un ventilateur de projection non protégé. Ne pas l’utiliser dans un endroit où il peut êtreaccessible aux personnes ou aux animaux.” PORTEZ DES GANTS ET ESSAYER D’EVITER LES BORDS COUPANTS! 6. Un écran de protection doit être installé hors d’atteinte du per sonnel à 7 feet (2 mètres environ) de la zone de travail oudans des limites raisonnables de sécurité. 2. Debido a que esta unidad tiene piezas rotativas, hay que tomar medidas de precaución a toda hora durante la instalación, operación y mantenimiento de la misma. 3. PRECAUCION: “Sólo para Empleo en Ventilación General. No Usar Como Extractor de Material y Vapores Peligrosos o Explosivos.” 4. Desempaque la unidad e inspecciónela antes de los 15 días de recibida. Si presenta daños, informe al transportista. No opere esta unidad si presenta daños visibles al conjunto de ventilador o impulsor. 5. PRECAUCION: “Esta unidad contiene un impulsor expuesto.No la utilice en sitios de fácil acceso por personas o animales.” ¡USE PROTECCION PARA LAS MANOS Y CUIDESE DE CANTOS O BORDES AFILADOS! 6. Hay que instalar rejillas de guarda al alcance del personal, a menos de (7) pies del sitio de la obra o donde quiera que hagan falta para protección. 7. PRECAUTION: Les ampoules utilisées dans les modéles fluorescents ne sont pas réglables. 7. PRECAUCIÓN: La bombilla utilizada en los modelos fluorescentes no es atenuable. 8. Attention: Utilisez seulement les ampoules «tcp xr3014 b» pour les modÈles fluorescents et les ampoules «par 16» pour les modèles halogènes. 8. PRECAUCIÓN: Utilice solamente focos fluorescentes Fantech (modelo PBB14) y focos de halogeno PAR16 / MR16 GU10 de un max de 50W (modelo PBB50) 9. VEUILLEZ, lire ce manuel en entier avant de l’installer. 9. FAVOR leer este manual por completo antes de proceder a la instalación. 3 Warnings Advertissements Advertencias DO NOT CONNECT POWER SUPPLY until fan is completely installed. Make sure electrical service to the fan is in the locked “OFF” position. NE PAS BRANCHER l’électricité jusqu’à ce que le ventilateur soit complètement installé. Veillez à ce que le tableau électrique du ventilateur soit verrouillé (“OFF”). NO CONECTE LA ALIMENTACION hasta tanto el ventilador quede completamente instalado. Cerciórese de que el servicio eléctrico al ventilador quede asegurado en la posición “OFF” (desactivado). 1. All fans are suitable for use with solid-state speed control. Three phase units must be wired through a motor contactor. 2. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING: a. Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer’s representative or contact us directly. b. CAUTION: Before installation, servicing or cleaning unit, switch power off at the service panel and lock the service disconnect to prevent power from being switched on accidentally. When the service disconnect cannot be locked, securely fasten a prominent warning device, such as tag, to the panel. c. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. d. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. e. When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities. f. Ducted fans must always be vented to the outdoors. g. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. h. NEVER place a switch where it can be reached from a tub or shower. 3. WARNING! Check voltage at the fan to see if it corresponds to the motor name plate. 1. Tous les ventilateurs sont faits pour être utilisés avec une commande de vitesse. Les appareils avec trois vitesses doivent être reliés à un interrupteur et un disjoncteur. 1. Todos los ventiladores vienen preparados para controlarse mediante controles de estado sólido. Las unidades trifásicas tienen que cablearse a través de un contactor de motores. 2. AVERTISSEMENTS POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DECHARGE ELECTRIQUE OU RISQUE DE BLESSURES. SUIVEZ LES CONSEILS SUIVANTS: a. Cet appareil ne doit pas être utilisé pour une autre fonction que celle prévue par son fabricant. Si vous avez des questions, contactez les représentants de vos fabricants ou contactez-nous directement. b. ATTENTION: Avant l’installation, le service ou le nettoyage de l’appareil, fermer l’électricité et fermer à clé le compteur électrique afin d’éviter que l’électricité ne soit retranchée accidentellement. Si le compteur ne peut pas être fermé à clé, attachez au compteur un dispositif de sécurité comme par exemple une étiquette. c. L’installation de l’électricité doit être faite par une personne qualifiée en accord avec les codes applicables et les règles pour la construction anti-feu. d. La circulation de l’air est nécessaire pour une bonne combustion et pour l’aspiration des gazs dans la cheminée afin d’éviter des refoulements. Suivez le guide de chauffage du fabriquant ainsi que les règles de sécurités comme celles qui sont éditées par l’Association Nationale des Sapeurs Pompiers (NFPA) et l ‘Association américaine des Ingénieurs pour le chauffage et l’air conditionné (ASHRAE) ainsi que celles des autorités locales. e. Lorsque vous coupez ou percez le mur et le plafond faites attention de ne pas endommager les câbles électriques des autres appareils utilitaires. f. Le ventilateur caréné doit toujours être branché sur l’extérieur. g. Si l’appareil doit être installé au-dessus d’une baignoire ou d’une douche, il doit être signalé comme tel pour son utilisation et l’installation d’une prise de terre est nécessaire. h. NE JAMAIS placer près de la baignoire ou de la douche un interrupteur à porté de la main. 2. ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, CONMOCION ELECTRICA O LESIONES A PERSONAS, OBSERVE LO SIGUIENTE: a. Sólo utilice esta unidad de la manera dispuesta por el fabricante. Si tiene cualquier pregunta, diríjase al representante del fabricante, o bien a nosotros directamente. b. PRECAUCION: Antes de la instalación, mantenimiento o limpieza de la unidad, desconecte la alimentación en el tablero de servicio y cierre con llave el interruptor del circuito para impedir la reactivación accidental. De no poder cerrarse el interruptor con llave, aplíquele al tablero una etiqueta o dispositivo de advertencia bien visible. c. Los trabajos de instalación y cableado eléctrico tienen que ser realizados por personal calificado conforme todos los códigos y normas del caso, incluso el código de incendio en la construcción. d. La debida combustión y extracción de gases a través de la chimenea de equipos quemadores de combustibles, requiere de una cantidad adecuada de aire que impida el contratiro. Siga las pautas y normas de seguridad del fabricante, tales como publica la National Fire Association (NFPA) (Asociación Nacional de Incendios) y la American Society for Heating Refrigeration and Air-conditioning Engineers (ASHRAE), así como las de las autoridades locales del código. e. Al cortar o perforar paredes y cielos rasos, tenga cuidado de no dañar el cableado eléctrico u otros servicios públicos ocultos. f. Los ventiladores montados en conductos siempre deben contar con respiraderos al exterior. g. Si esta unidad ha de instalarse por encima de una bañera o ducha, tiene que venir marcada como tal par dicha aplicación y conectarse a un circuito protector interruptor de circuitos de tierra falla. h. JAMAS coloque un interruptor al alcance de una bañera o ducha. 3. ATTENTION : Vérifier le voltage afin de voir s’il correspond à celui indiqué sur la plaque du moteur. 3. ¡ADVERTENCIA! Revise el voltaje entrante al ventilador para constatar que corresponda al que indica la placa de fábrica. fantech 4 Installating Fan and Bracket Electrical Connection 1. Before selecting mounting location for fan, consider the following: a) Mounting the fan as far as possible from the intake point will assure quiet operation. A minimum of 8’ of insulated flexible duct is recommended between exhaust grille and fan. 1. Remove the screws securing the terminal box cover located on the fan motor mounting bracket. All fan motor and capacitor connections are prewired to an electrical terminal strip. A 3/8" romex type cable restraint connector will be needed to secure the wiring through the knockout on the side of the terminal box. b) Place fan where it can be easily accessed for service. 2. Attach the mounting bracket to a support beam with wood screws provided. Fan can be mounted at any point along the duct and at any angle. Vertical mounting is recommended to reduce condensation in the fan. For horizontally mounting, either wrap insulation around the fan or drill a 1 1/4" hole in the bottom of the housing. Add NPT insert and drain tube (purchased separately) for drainage of condensation­­­­. 3. For PB Series fans, if bracket is used to mount fan, refer to illustration 1. If suspending fan with hanger straps, refer to illustration 2. 4. Connect duct to inlet and outlet of fan using plastic ties or duct tape (purchased separately). When using insulated flexible duct, the inner vinyl core should be clamped or taped to the inlet and outlet and the vapor barrier surrounding the insulation should be duct taped to the fan housing. Note: Steps 2 & 3 may be reversed. 2. Bring incoming electrical service through the romex connector and the fan electrical service opening. Be sure to place the connector nut over the wiring coming into the terminal box. There are two open ports on the terminal strip. Using a small regular screwdriver, tighten the neutral (white) wire of the incoming supply under the open terminal strip port labeled “N”. Tighten the line (black) wire of the incoming supply under the open terminal strip port labeled “L” to the ground connection on the terminal block. 3. Secure the romex connector. Secure the incoming supply with the romex connector. Place the capacitor back into the terminal box. Replace the fan terminal box cover. All fan motor and capacitor connections have been prewired from the factory. No additional fan wiring is necessary. Wiring Diagrams Without Motor Speed Controller Fantech recommends insulated flexible duct for all bathroom exhaust applications. Illustration 1 • • • • • • • • • PB110 PB110F PB110H PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 • PB370-2 With Motor Speed Controller Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws. Multiple Location Switching Wiring Diagram Mounting Bracket & Screw Locations for FG • PB110 • PB110F • PB110H Illustration 2 • • • • • • • PB370-2 PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 Clamp Fastener Fans may be suspended without special mounting brackets. Duct Fan Troubleshooting Spiral duct Vibration absorbing material Flexible Duct Installation Hints Fantech strongly recommends the use of flexible insulated duct where ducting passes through unconditioned space or where noise is a factor. Check local code requirements before installing. Failure to use insulated flexible duct could result in excessive condensation buildup within the duct, and undesirable sound levels within the room. A minimum of 8' of insulated flexible duct is recommended between the fan and any inlet grille. Duct should be stretched as tight and straight as possible. Failure to do so could result in dramatic loss of system performance. Connect flex duct to the fan with plastic zip ties or duct tape. Connections should be airtight as possible for maximize performance. fantech WARNING Maximum torque that can be applied to the terminal block screws is 0.79 Nm (7 lb-in). If fan fails to operate, please check the following: 1. Consult wiring diagrams (above) to ensure proper connection. 2. Check motor lead wiring, capacitor leads and incoming supply leads to insure definite contact. 3. If possible, use a meter to test for continuity across the fan motor leads. In order to do this, the capacitor must be disconnected (do not test the capacitor - it will not meter continuity). If motor leads show continuity, consult factory for a replacement capacitor. Maintenance Instructions Since fan bearings are sealed and provided with an internal lubricating material, no additional lubrication is necessary. 5 Installation of Ceiling Grille Housing With or Without Light Figure 1 1. Plan Location of Inlet Grilles Based on the bathroom layout and fixtures, plan the location of the ceiling grilles for the most effective ventilation. 2. Securing the Housing to the Ceiling Joists NEW CONSTRUCTION  ount housing directly to the ceiling joist using screws and keyhole slots. M Locator tabs on housing should be flush with the bottom edge of the ceiling joist for correct positioning of the unit once drywall is installed (Figure 1). OR Use the hanger bars to suspend the housing between ceiling joists. For correct positioning, hanger bars should be positioned 3/16" up from the bottom edge of the ceiling joist on models with 4" duct connection and 15/ " up from bottom edge of joist on models with 6" duct connection. On 32 models with 4" duct, tighten anti-slide screws to keep hanger bars in place. (Figure 2). Postion Locator Tabs flush with bottom edge of joist Figure 2 Note: Hanger bars on units with 4" duct connection can be used on ceiling joists up to 24" on center. Hanger bars on units with 6" duct connection span ceiling joists up to 16" on center. Note: If drywall or ceiling material is thicker than 5/8" the locator tabs may be removed to allow the grille collar to be flush with the finished ceiling material. When ceiling drywall is being installed, cut hole for ceiling grille. EXISTING CONSTRUCTION OR WHEN DRYWALL IS IN PLACE. Cut a 6" round hole for the ceiling grille only and install the housing from the attic (Figure 3). Place the housing against the ceiling joist using the locator tabs to determine the correct position (Figure 1) or align it using the hanger bars (Figure 2). Punch out the keyhole knockouts (if using) and the electrical knockout if needed. To complete installation for Bath Fan models with lights, continue with steps 3 through 5. For models without lights, skip to steps 4 and 5. Housings with 4" duct: 3/16" from bottom edge of joist. Housings with 6" duct: 15/32" Anti-slide locking screw on models with 4" duct. Figure 3 Figure 4 3. Make Electrical Connections to the Ceiling Grille Housing. Remove the electrical cover inside the steel housing using a screwdriver. Connect power by following wiring diagram (Figure 5) and following local or National Electrical Codes. Replace the electrical cover. 4. Connect the Fan to the Ceiling Grille Housing(s). Install appropriate diameter duct from the fan to the ceiling grille housing. (Insulated flexible duct is recommended for all Fantech bathroom exhaust applications for quieter operation.) For dual grille models, install duct between fan and wye adapter* (included). Then, attach duct to each leg of the wye and to each ceiling grille housing. Secure duct in place and seal. If using insulated flexible duct, seal the inner liner to the duct connector then seal the outer shell over the top of the inner liner. Do not leave the insulation material exposed. 5. Installing the Bulb. Install the bulb by gently inserting it into the socket in the grille housing. Install the grille by pushing it firmly into the steel collar until it is shouldered by the ceiling drywall (Figure 3). Repeat steps 1 through 5 for each additional ceiling grille housing being installed. Additional steps required when installing a fluorescent model over a tub or shower (Figure 4) 1. Place ring 1 on on socket legs first. 2. Screw metal shield in place over socket. 3. Add rubber gasket 4. Secure ring 2 to socket. Click indicates a secure installation. Shield Ring 2 Gasket Screw Ring 1 Grille Fluorescent lamp SCALE 3/10 Socket Figure 5 Electrical *For most efficient operation wye adapter should be positioned the equivalent of three duct diameters away from the fan inlet. fantech 6 Dimensions Housing Dimensions of 4" duct models Housing Dimensions of 6" duct models 9 11/16" (246mm) 9 /16" (243mm) 9 8" (205mm) 8 15/16" (227mm) 5 /16" (8mm) 5 13/16" (148mm) 13 /16" (21mm) All dimensions are in inches and mm. fantech 5 1/16" (148mm) 9" (230mm) 17 1/4" (438mm) 6" (150mm) 5 5/16" (134mm) 4" (102mm) 7 3/16" (182.5mm) 7 Planifier l’emplacement du ventilateur Branchement électrique 1. Avant de choisir l’emplacement de votre ventilateur, prenez en considération : 1. Retirez les vis fixant le couvercle de la boîte de câblage sur le côté du ventilateur. Tous les fils du moteur du ventilateur sont préalablement câblés à une bande de branchement électrique. Un connecteur câble encastré de type «Romex» 15,8 mm sera nécessaire afin de fixer le fil d’alimentation à la boîte de câblage. a) Plus loin vous installerez le ventilateur du point d'entrée, moins vous entendrez du bruit de la pièce que vous ventilez. b) Assurez-vous que le ventilateur soit accessible. 2. Attachez le support à une poutre du support à l’emplacement choisi à l'aide des vis fournies. Le support vertical est recommandé pour réduire la formation de condensation dans le ventilateur. Pour une installation horizontale, enroulez alors l’isolation autour du ventilateur ou faites un trou de 1¼ po dans le bas de la boîte (avec une insertion de NPT et une tuyauterie de vidange) permet à la condensation de s’écouler. 3. Pour les ventilateurs de la sèrie PB on utilise un support pour installer le ventilateur, se référer à l’illustration 1. Si le ventilateur va être suspendu au moyen de courroies, voir l’illustration 2. 4. Branchez les tuyaux d'entrée et de sortie à l'aide de colliers de serrage en plastique ou de ruban adhésif en toile (non inclus). Lorsque vous utilisez des conduits flexibles isolants, la paroi intérieure en vinyle devrait être fixée à l'aide d'un collier de serrage ou de ruban adhésif en toile sur la prise d'entrée et de sortie et la barrière de vapeur entourant l'isolation devrait etre fixée au boîtier à l'aide de ruban adhésif en toile. Fantech recommande le conduit flexible isolant pour toutes les applications d'évacuation pour salles de bains. 2. Passez les fils d’alimentation à travers le connecteur de câble encastré. Assurez-vous de placer l’écrou du connecteur au-dessus des fils entrant dans la boîte de câblage. Il y a deux emplacements libres sur la bande de branchement. À l’aide d’un tournevis régulier, serrez le fil d’alimentation blanc sous la vis indiquée « N ». Serrez le fil d’alimentation noir sous la vis indiquée «L». Puisque le moteur du ventilateur est isolé dans un boîtier en plastique, la prise de terre n’est pas nécessaire. 3. Fixez le connecteur «Romex». Fixez l’entrée de l’alimentation avec le connecteur «Romex». Replacez le couvercle de la boîte de câblage. Tous les fils du moteur ayant été préalablement câblés à l’usine, aucun autre raccordement est nécessaire. Diagramme de branchement Sans contrôle de vitesse du moteur Mise à la terre Vert/Jaune Mise à la terre Mise à la terre Vert/Jaune Vert/Jaune NOTE : Les étapes 2 et 3 peuvent être inversées. Illustration 1 • • • • • • • • • PB110 PB110F PB110H PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 Avec contrôle de vitesse du moteur • PB370-2 Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws. • • • • • • Vert/Jaune Mise à la terre Mise à la terre Vert/Jaune Vert/Jaune Diagramme de pour plusieurs pièces Misebranchement à la terre Mise à la terre Mise à la terre Placement des vis de montage et du crochet • PB110 • PB110F • PB110H Mise à la terre Illustration 2 Les ventilateurs peuvent être suspendus sans aucun supports de montage spéciaux. Matériel absorbant le vibration Vert/Jaune Vert/Jaune • PB370-2 PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 Adapteur pour attaches Vert/Jaune Ventilateur Dépannage Avertissement Le couple maximal qui peut être appliqué aux vis du bornier est de 0.79 Nm (7 lb-in). Si le ventilateur ne fonctionne pas, vérifiez ce qui suit : Conduit en spirale Conseils pour l’installation de tuyaux flexibles Fantech recommande fortement l'utilisation de tuyaux flexibles isolants dans les pièces à ventilation non contrôlée, ou pour minimiser le bruit. Consultez les codes de votre région avant l'installation. Faute d’utiliser les conduits flexibles isolants pourrait causer une accumulation excessive de condensation dans le conduit et un niveau de bruit nuisible dans la pièce. Un minimum de 8 pieds de tuyau flexible isolant est recommandé entre la grille et le ventilateur. Il devrait être étiré à son maximum et être aussi droit que possible, sans quoi la performance en serait grandement diminuée. Fixez le tuyau flexible au ventilateur avec un collier de serrage ou un ruban adhésif en toile. Le branchement doit être le plus étanche que possible afin de maximiser le rendement du système. 1. Consultez les diagrammes de câblage (voir ci-dessous) pour vous assurer que la connexion est appropriée. 2. Contrôlez le fil de sortie du moteur, les fils de sortie du condensateur et l’alimentation électrique pour vous assurer d’un bon contact. 3. Si possible, utilisez un appareil de mesure pour déterminer la continuité àtravers les fils de sortie du moteur du ventilateur. Pour faire ceci, le condensateur doit être débranché (ne pas tester le condensateur - il ne montrera pas la continuité). Si les fils de sortie du moteur montrent la continuité, consultez l’usine pour un condensateur de rechange. Instructions pour l'entretien Puisque les roulements du ventilateur sont scellés et équipés d’un matériel lubrifiant interne, aucune lubrification supplémentaire n’est nécessaire. fantech 8 Installation du boîtier avec ou sans éclairage 1. Planifiez l'endroit pour la grille D'après votre salle de bain et ses installations, planifiez l'endroit où vous installerez vos grilles de plafond pour une ventilation efficace. 2. Fixez le boîtier à la poutrelle du plafond. Nouvelle CONSTRUCTION Fixez le boîtier directement sur la poutre du plafond avec les vis. Les languettes sur le boîtier devraient être au même niveau que le côté inférieur de la poutrelle du plafond (Figure 1). OU Utilisez les barres de suspension pour fixer le boîtier à la poutrelle du plafond. Pour être exacte, les barres de suspensions doivent être à 3¼16 po au-dessus du côté inférieur de la poutrelle du plafond pour les modèles à collets de 4 po et 15¼32 po pour les modèles de 6 po. Sur les modèles à conduits de 4 po serrez les vis anti-dérapantes pour sécuriser les barres de suspension en place (Figure 2). Note: Les barres de suspension des appareils à collets de 4 po peuvent être utilisées sur les poutrelles de plafond jusqu'à 24 po du centre. Les barres de suspension pour les appareils à conduits de 6 po peuvent aller jusqu'à 16 po du centre. Note: Si le gypse ou le matériel de plafond est plus épais que 5¼8 po, les languettes de position peuvent être enlevées pour permettre au collier de la grille d’être au même niveau que le plafond fini. Lorsque le gypse est posée au plafond, pratiquez une ouverture pour accomoder la grille. Dégagez l’ouverture pour les fils d’alimentation de la boîte de câblage. Étapes additionnelles lors de l’installation d’un modèle fluorescent au-dessus d’une baignoire ou d’une douche (Figure 4). 1. Placer l’anneau « 1 » sur la douille, en commençant par les pattes. 2. Visser le panneau en métal sur la douille. 3. Ajouter le joint en caoutchouc. 4. Bien attacher l’anneau « 2 » sur la douille. Le clic indique une installation sécurisée. Figure 1 Postionnez les languettes de position à la poutrelle du plafond Figure 2 CONSTRUCTION existante ou gypse en place. Percez un trou de 6 po pour la grille de plafond seulement et installer le boîtier dans le grenier. Placez le boîtier sur la poutrelle de plafond en utilisant les locator tabs pour déterminer l'emplacement exacte (Figure 1) ou enligner en utilisant les barres de suspension (Figure 2). Percez un trou si nécessaire. Pour compléter l'installation des ventilateurs pour salle de bains avec éclairage, suivez les étapes 3 à 5. Pour les modèles sans éclairage, passez directement aux étapes 4 et 5. Boîtier avec un conduit de 4 po : 3 ¼16 po du dessous de la poutrelle. Boîtiers avec 6 po : 15 /32 po Vis anti-dérapante sur modèles à conduits de 4 po. Figure 3 Figure 4 3. Faites la connexion électrique au boîtier de la grille au plafond. En utilisant un tournevis, enlevez le couvercle électrique à l’intérieur du boîtier en métal. Connectez le courant en suivant le diagramme de branchement (Figure 5) et en suivant les codes électriques locaux ou les codes électriques nationaux. Remettez le couvercle électrique. Panneau Anneau 2 Joint Vis 4. Raccordement du ventilateur du boîtier. Installez le conduit de 4 po ou de 6 po du ventilateur au boîtier de la grille au plafond. (Les conduits flexibles isolants recommandés par Fantech pour toutes applications d’évacuation pour salle de bains vous donneront un rendement plus silencieux). Pour les modèles à grilles jumelles, montez les conduits entre le ventilateur et l’adapteur « wye » (inclus), puis reliez les conduits à chaque sortie du « wye » et à chaque boîtier des grilles. Attachez les conduits en place, puis scellez. Si vous utilisez un tuyau flexible isolant, scellez la couche intérieure au connecteur de conduit puis scellez la couche extérieure couvrant la couche intérieure. Ne laissez pas le matériel isolant exposé. 5. Installation de l'ampoule. Procédez en insérant doucement l’ampoule dans la douille située dans le boîtier de la grille. Posez la grille en la poussant fermement le collier jusqu’à ce que la grillle soit en contact ferme avec le plafond. (Figure 3). Répétez les étapes 1 à 6 pour chaque boîtier de grille pour plafond additionnel à installer. *Pour un fonctionnement plus efficace, l’adapteur « wye » devrait être positionné à une distance égale à trois fois le diamètre du conduit de l'entrée du ventilateur. fantech Anneau 2 SCALE 3/10 Grille Ampoule Fluorescente Figure 5 Douille Électrique 9 Dimensions Dimension du boîtier des modèles à conduit de 4 po Dimension du boîtier des modèles à conduit de 6 po 9 11/16" (246mm) 9 /16" (243mm) 9 8" (205mm) 8 15/16" (227mm) 6" (150mm) 5 5/16" (134mm) 5 1/16" (148mm) 9" (230mm) 5 /16" (8mm) 5 13/16" (148mm) 13 /16" (21mm) 4" (102mm) 7 3/16" (182.5mm) Toutes les dimensions sont en pouces. fantech 10 Instalación del extractor en la pared exterior 1. Antes de elegir la posición para la instalación del ventilador, considere los puntos siguientes: a) Instalar el ventilador lo más alejado posible al punto de admisión garantiza una operación silenciosa. Se recomienda un mínimo de ducto flexible aislado de 8’ entre la rejilla de escape y el ventilador. b) Coloque el ventilador en un lugar de fácil acceso para darle servicio. 2. Fije el soporte de instalación a una vigueta de soporte con los tornillos para madera incluidos. Es posible instalar el ventilador en cualquier punto a lo largo del ducto y en cualquier ángulo. Se recomienda la instalación vertical para reducir la condensación en el ventilador. Para instalaciones horizontales, enrolle aislante alrededor del ventilador o perfore un agujero de 1¼" en la base de la caja. Agregue el inserto NPT y la manguera de drenaje (comprada por separado) para el drenaje de la condensación. 3. Para los ventiladores Modelo FG, si han de montarse en un soporte, refiérase a la Ilustración 1. Si ha de colgarse un ventilador con tirantes, refiérase a la Ilustración 2. 4. Conecte el conducto a la entrada y salida del ventilador con abrazaderas de plástico tipo CB [de terceros] o con cinta especial para conductos. Cuando se usen conductos flexibles con aislamiento, se recomienda que el núcleo de vinilo se sujete con abrazadera o cinta a la entrada y a la salida y que la barrera contra vapor que rodea el material aislante se fije con cinta para conductos a la caja del ventilador. Fantech recomienda el uso de conductos flexibles y aislados para todas las aplicaciones de escape en el baño. NOTA: Se puede invertir el orden de los pasos 2 y 3. Ilustración 1 • • • • • • • • • PB110 PB110F PB110H PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 • PB370-2 Consulte los requerimientos del código local antes de la instalación. Para lograr la instalación más silenciosa posible, Fantech recomienda un mínimo de 8 pies de conducto flexible aislado entre cualquier rejilla de admisión y el ventilador. Al montar un conducto de tipo flexible, el mismo se debe instalar lo más apretado y recto posible. De lo contrario, el sistema podría sufrir una importante pérdida de rendimiento. El conducto flexible se debe conectar al ventilador con abrazaderas de plástico tipo CB o con cinta para conductos. Todas las conexiones deben quedar lo más herméticas posible para lograr un máximo rendimiento. Conexión eléctrica 1. Quite los tornillos de montaje de la tapa de la caja de conexiones en el costado del ventilador. Todas las conexiones del motor del ventilador están precableadas a una regleta eléctrica. Se necesitará un conector de fijación de cables tipo romex de 3/8" para sujetar el cableado a través del agujero ciego provisto en el costado de la caja de conexiones. 2. Pase la alimentación eléctrica a través del conector romex y el agujero ciego del ventilador. Tenga cuidado de colocar la tuerca del conector encima del cableado que entra a la caja de conexiones. En la regleta de conexiones hay dos lumbreras abiertas. Con un pequeño destornillador estándar, apriete el cable neutro (color blanco) de la alimentación eléctrica debajo de la lumbrera marcada “N” en la regleta. Apriete el hilo de línea (negro) de la alimentación eléctrica debajo de la lumbrera marcada “L”. Dado que el motor del ventilador está aislado por su carcasa de plástico, no es necesario conectarlo a tierra. 3. Asegure el conector romex. Asegure la alimentación entrante con el conector romex. Vuelva a colocar la tapa de la caja de conexiones del ventilador. Todas las conexiones del motor del ventilador y del capacitor vienen precableadas de fábrica. No hace falta ningún cableado adicional para el ventilador. Diagramas de cableado Tierra (Verde/Amarillo) (Verde/Amarillo) Tierra Condensador Fan bracket should be installed, then fan mounted directly to bracket using sheet metal screws. Sin controlador de velocidad de motor Soporte Montura Y Tornillo Localización • PB110 • PB110F • PB110H (Verde/Amarillo) Con controlador de velocidad de motor Tierra • • • • • • PB190 PB270-2 PB270F-2 PB270H-2 PB270FV-2 PB270HV-2 • PB370-2 Tierra (Verde/Amarillo) Tierra Tierra (Verde/Amarillo) (Verde/Amarillo) (Marrón) (Marrón) (Marrón) Diagrama de cableado para conmutación desde varios puntos Ilustración 2 Tornillo de Abrazadera Condensador Condensador Ventilador en Conducto Los ventiladores se pueden colgar sin necesidad de soportes especiales. Tierra (Verde/Amarillo) Tierra Tierra (Verde/Amarillo) (Azul) (Verde/Amarillo) (Azul) (Negro) (Azul) (Negro) (Marrón) (Negro) (Marrón) (Marrón) Conducto Material amotiguador en Espiral Sugerencias para la instalación del conducto flexible Fantech recomienda firmemente el uso de ducto aislado flexible cuando los ductos atraviesan espacios no acondicionados o donde el ruido sea un factor a considerar. fantech Conmutación de posición múltiple Conmutación de posición múltiple Conmutación de posición múltiple Advertencia El par máximo que se puede aplicar a los tornillos de la caja de bornes es de 0.79 Nm (7 lb-in). 11 Análisis de fallas Si el ventilador deja de funcionar, revise lo siguiente: 1. Consulte los diagramas eléctricos (a la derecha) para asegurar que las conexiones se hagan correctamente. 2. Revise el cableado del motor, del capacitor y de la alimentación eléctrica para asegurar el debido contacto. 3. Si es posible, use un comprobador para verificar la continuidad entre los hilos del motor del ventilador. Para ello, se debe desconectar el capacitor. (No pruebe el capacitor, ya que no tiene continuidad.) Si los hilos del motor muestran continuidad, solicite a la fábrica un capacitor de repuesto. Instrucciones de mantenimiento Puesto que los rodamientos del ventilador están sellados y provistos de lubricante interno, no es necesario aplicarles lubricante adicional. Instalación de la caja de rejilla de techo con o sin luz 1. Planee la ubicación de las rejillas de admisión. Con base en el diseño y el mobiliario del baño, planee la ubicación de las rejillas del techo para obtener la ventilación más efectiva. 2. Fije la caja a las viguetas del techo. CONSTRUCCIÓN NUEVA Fije la caja directamente en la vigueta del techo con tornillos y las ranuras de alineación. Las pestañas de ubicación en la caja deben estar a nivel con el borde inferior de la vigueta del techo para la correcta ubicación de la unidad una vez instalada la tablarroca. (Figura 1) O Utilice las barras de soporte para sujetar la caja entre las viguetas del techo. Para su colocación correcta, las barras de soporte deben colocarse a 13/16" arriba del borde inferior de la vigueta del techo en los modelos con conexión de ducto de 4" y 15/32" arriba del borde inferior de la vigueta en los modelos con conexión con ducto de 6”. En los modelos con ducto de 4", apriete los tornillos antideslizantes para mantener las barras de soporte en su sitio. (Figura 2). 3. Efectúe las conexiones eléctricas a la caja de la rejilla de techo. Con un destornillador, retire la tapa eléctrica del interior del gabinete de acero. Conecte la alimentación conforme a los diagramas de cableado (Figura 5) y cumpliendo con los códigos locales o nacionales sobre instalaciones eléctricas. Vuelva a colocar la tapa eléctrica. 4. Conecte el ventilador a la caja de la rejilla de techo. Instale el conducto de 4" o 6" desde el ventilador hasta la caja de la rejilla. El uso de conducto flexible con aislamiento (recomendado para todas las aplicaciones de ventilación de baños de Fantech) producirá un funcionamiento más silencioso. Sujete el conducto en su lugar y séllelo. Si se usa conducto flexible con aislamiento, selle el forro interior al conector del conducto, a continuación selle la carcasa exterior por sobre el forro interior. No deje al descubierto el material aislante. 5. Instalación de la bombilla. Instale la bombilla introduciéndola con cuidado en el portabombillas dentro del gabinete de acero. Para instalar la rejilla empújela firmemente hacia el collarín de acero hasta quedar a ras del panel de yeso del techo (Figura 3). Repita los pasos del 1 al 5 para cada caja de rejilla de techo que se instale. * Para obtener una operación más eficiente el adaptador en “Y” debe colocarse a una distancia equivalente a tres diámetros del ducto del ventilador de admisión. Pasos adicionales necesarios cuando se instala un modelo fluorescente encima de una bañera o ducha (Figura 4) 1. Coloque el aro 1 sobre el casquillo, con las patas primero. 2. Atornille la placa protectora de metal sobre el casquillo. 3. Instale la guarnición de goma. 4. Fije el aro 2 en el casquillo. El chasquido indica la instalación segura. Nota: Las barras de soporte en las unidades con conexión de ducto de 4" pueden emplearse en viguetas de techo de hasta 24" en el centro. Las barras de soporte en las unidades con conexión de ducto de 6" abarcan las viguetas del techo hasta una distancia de 16" desde el centro. Nota: Si el grosor del panel de yeso o del material del techo es de más de 5/8" ahora puede retirar las pestañas guías. Durante la instalación de la tablarroca, corte un hueco para la rejilla del techo. CONSTRUCCIÓN EXISTENTE O CUANDO LA TABLARROCA ESTÁ EN SU SITIO Corte una orificio redondo de 6” sólo para la rejilla e instale la caja desde el altillo. (Figura 3) Coloque la caja contra la vigueta del techo. Para completar la instalación en los modelos de ventilador para baño con luz, continúe con los pasos del 3 al 5. Para los modelos sin luces, vaya a los pasos 4 y 5. Perfore los agujeros ciegos (si se van a usar) y el que corresponda al cable eléctrico si es necesario. Siga con los pasos 3 a 5 para continuar con la instalación de los modelos de ventiladores para baño Premium con luces. De lo contrario, siga a los pasos 4 y 5 para completar la instalación de los modelos sin luces. fantech 12 Dimensiones Figure 1 Dimensiones de la caja de los modelos de conductos de 4" 9 9/16" (243mm) /16" (21mm) Coloque las pestañas guías al ras con el borde inferior de la vigueta. 8 15/16" (227mm) 5 5/16" (134mm) 5 13 Figure 2 5 13/16" (148mm) /16" (8mm) 4" (102mm) 7 3/16" (182.5mm) Todas las dimensiones son en pulgada. Dimensiones de la caja de los modelos de conductos de 6" 9 11/16" (246mm) 8" (205mm) Tornillo antideslizante de seguridad en modelos con ducto de 4". Figure 3 6" (150mm) Cajas con ducto de 4": A 3/16" desde la base inferior de la vigueta. Cajas con ducto de 6”: 15/32" Figure 4 Aro 2 Planca Guarnición 5 1/16" (148mm) 9" (230mm) Tornillo Aro 1 Todas las dimensiones son en pulgada. SCALE 3/10 Grille Bombilla Fluorescente Socket Figure 5 Eléctrico Tierra fantech Casquillo 13 Warranty 7 Year Warranty This warranty supersedes all prior warranties DURING ENTIRE WARRANTY PERIOD: Fantech will repair or replace any part which has a factory defect in workmanship or material. Product may need to be returned to the Fantech factory, together with a copy of the bill of sale and identified with RMA number. FOR FACTORY RETURN YOU MUST: • Have a Return Materials Authorization (RMA) number. This may be obtained by calling Fantech either in the USA at 1.800.747.1762 or in CANADA at 1.800.565.3548. Please have bill of sale available. • The RMA number must be clearly written on the outside of the carton, or the carton will be refused. • All parts and/or product will be repaired/replaced and shipped back to buyer; no credit will be issued. OR The Distributor may place an order for the warranty part and/or product and is invoiced. The Distributor will receive a credit equal to the invoice only after product is returned prepaid and verified to be defective. Fantech WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL. DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO THE END USER, AS CREDIT TO DISTRIBUTOR’S ACCOUNT WILL BE PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY Fantech. THE FOLLOWING WARRANTIES DO NOT APPLY: • Damages from shipping, either concealed or visible. Claim must be filed with freight company. • Damages resulting from improper wiring or installation. • Damages or failure caused by acts of God, or resulting from improper consumer procedures, such as: 1. Improper maintenance 2. Misuse, abuse, abnormal use, or accident, and 3. Incorrect electrical voltage or current. • Removal or any alteration made on the Fantech label control number or date of manufacture. • Any other warranty, expressed, implied or written, and to any consequential or incidental damages, loss or property, revenues, or profit, or costs of removal, installation or reinstallation, for any breach of warranty. WARRANTY VALIDATION • The user must keep a copy of the bill of sale to verify purchase date. • These warranties give you specific legal rights, and are subject to an applicable consumer protection legislation. You may have additional rights which vary from state to state. Limitation of Warranty and Liability This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse, incorrect electrical connections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts. We will not approve for payment any repair not made by us or our authorized agent without prior written consent. The foregoing shall constitute our sole and exclusive warranty and our sole exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description on the page hereof. In no event, whether as a result of breach of contract, or warranty or alleged negligence, defect incorrect advice or other causes, shall Fantech be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of equipment or any other associated equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs, or claims of customers of purchase for such damages. Fantech neither assumes or authorizes any person to assume for it any other liability in connection with the sale of product(s) or part(s). Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you. Warning Fantech products are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100% free from defects. Even reliable products will experience occasional failures and this possibility should be recognized by the user. If these products are used in a life support ventilation system where failure could result in loss or injury, the user should provide adequate backup ventilation, supplementary natural ventilation, failure alarm system, or acknowledge willingness to accept the risk of such loss or injury. fantech 14 Garantie Garantie de 7 ans Cette garantie remplace toutes les garanties précédentes. DURANT TOUTE LA PÉRIODE DE GARANTIE: Fantech s'engage à réparer ou à remplacer toute pièce présentant un défaut d'usine en matière de qualité d'exécution ou de matériau. Il sera peut être nécessaire de retourner le produit à l'usine Fantech, accompagné d'une copie du contrat de vente et du numéro d'autorisation de retour. POUR RETOURNER UN PRODUIT À L'USINE, VOUS DEVEZ: • Obtenir un numéro d'autorisation de retour; pour ce faire, communiquer avec Fantech aux États-Unis au numéro 1.800.747.1762, ou au Canada, au numéro 1.800.565.3548. Veuillez avoir votre contrat de vente à portée de la main. • S'assurer que le numéro d'autorisation de retour est lisible sur l'extérieur de la boîte, sinon la boîte sera refusée. • Toutes les pièces et/ou le produit seront réparés ou remplacés puis retournés à l'acheteur. Aucun crédit ne sera accordé. OU Le Distributeur peut commander une pièce ou un produit couvert par la garantie; la facture lui sera envoyée. Le distributeur ne sera crédité du montant de sa facture qu'après que le produit a été retourné port payé et qu'il a été trouvé défectueux. LES TERMES DE LA GARANTIE DE Fantech NE PRÉVOIENT PAS DE REMPLACEMENT SANS FRAIS AVANT QUE LA PIÈCE OU LE PRODUIT DÉFECTUEUX AIT ÉTÉ INSPECTÉ. LES PRODUITS OU PIÈCES REMPLACÉS AVANT L'INSPECTION DE LA DÉFECTUOSITÉ SERONT FACTURÉS ET LE MONTANT DU CRÉDIT EST FONCTION DE L'INSPECTION DE LA PIÈCE OU DU PRODUIT RETOURNÉ. LE DISTRIBUTEUR NE DOIT PAS REMPLACER SANS FRAIS POUR L'UTILISATEUR FINAL L'ÉQUIPEMENT DÉFECTUEUX RETOURNÉ PAR L'UTILISATEUR FINAL, CAR LE COMPTE DU DISTRIBUTEUR NE SERA CRÉDITÉ QU'APRÈS L'INSPECTION ET LA VÉRIFICATION PAR Fantech DE LA DÉFECTUOSITÉ. LES GARANTIES NE S'APPLIQUENT PAS DANS LES CAS SUIVANTS: • Dommages dus au transport (dissimulés ou visibles). Les réclamations doivent être faites à la compagnie de fret. • Dommages dus au mauvais câblage ou à l'installation inappropriée. • Dommages ou défectuosité causés par une calamité naturelle ou résultant d'une procédure irrégulière de l'acheteur, notamment : 1. Entretien irrégulier 2. Mauvais usage, usage abusif, usage anormal ou accident 3. Tension ou courant électrique incorrect • Enlèvement ou toute modification du numéro de contrôle ou de la date de fabrication de l'étiquette Fantech • Toute autre garantie expresse, écrite ou implicite, pour les dommages accidentels ou indirects, perte de biens, de recettes, manque à gagner ou coûts relatifs à la dépose, à l'installation ou à la réinstallation, en cas de violation de garantie. CERTIFICATION DE LA GARANTIE: • L'utilisateur doit conserver une copie du contrat de vente pour confirmer la date d'achat. • Les présentes garanties vous donnent des droits spécifiques reconnus par la loi et sont régies par les lois sur la protection du consommateur appropriées. Il est possible que différents états offrent d'autres droits. Limites de garanties et de responsabilités Cette garantie ne s’applique à aucun produit de Fantech ou à aucune pièce détachée dont la défectuosité relève d’une erreur d’installation ou d’abus ou de mauvaise installation électrique ou dut à des modifications extérieures ou utilisées dans des conditions anormales ou encore une mauvaise installation du produit ou des pièces détachées. Nous n’approuverons aucun remboursement pour des réparations qui ne sont pas effectuées par un agent américain ou un agent autorisé sans un accord écrit. Ce dernier constituera notre seule et exclusive garantie et notre seule exclusive responsabilité et tient lieu de toute autre garantie ou bien écrite ou orale implicite ou statuaire. Aucune garantie ne s’appliquera au-delà des descriptions faites de la page ci-dessus. En aucun cas, que ce soit pour une rupture de contrat ou de garanties ou des dommages dut à la négligence ou a des conseils incorrects ou autres causes, Fantech ne pourra être tenu pour responsable des dommages particuliers ou consécutifs, incluant mais pas limités aux pertes et profits ou bénéfices perte de matériel ou autres matériels associés. Coût du capital, coût des équipements de remplacement, matériels ou services, coût de temps d’arrêt ou les réclamations des clients pour de tels dommages. Fantech ne délègue ou autorise aucune personne d’assumer sa responsabilité sur la vente du produit ou des pièces détachées. Certaines juridictions ne permettent pas l’exclusion de la limitation des dommages accidentels ou consécutifs ainsi ces limitations ci-dessus et les exclusions ne s’appliquent pas à vous. Avertissement Les produits de Fantech sont conçus et fabriqués pour produire des performances fiables, mais il n’y a aucune garantie qu’ils soient 100% sans défaut. Les plus produits les plus fiables ont occasionnellement des défectuosités et cette possibilité devraient être reconnu par les usagers. Si ces produits sont utilisés comme une source de ventilation ou leur fantech panne risque de mettre en danger des vies humaines ou entraîner des blessures, les usagers devront avoir une source de ventilation de secours en addition à une ventilation naturelle, le défaut de système d’alarme ou la connaissance de ces conditions entraînent sa responsabilité envers de telles pertes ou blessures. 15 Garantia Garantia de 7 Años Esta garantia de sin efecto cualquier otra garantia anterior DURANTE EL PERÍODO INTEGRO DE LA GARANTÍA: Fantech reparará o reemplazará toda parte que presente un defecto en el material o en la mano de obra. Es posible que el producto deba ser devuelto a la fabrica Fantech, juntamente con una copia de la constancia de compraventa e identificado con el número de RMA. PARA DEVOLUCIÓN A FÁBRICA USTED DEBE: • Tener un número de Autorización de Devolución de Material (RMA). Esto se puede obtener llamando a Fantech ya sea en los Estados Unidos al 1.800.747.1762 • en Canadá al 1.800.565.3548. Tenga a mano la constancia de compraventa. • El número de RMA deberá estar claramente escrito en la parte exterior de la caja, de lo contrario la caja será rechazada. • Todas las partes y/o el producto serán reparados/reemplazados y devueltos al comprador; no se otorgará crédito. O BIEN El Distribuidor puede colocar una orden por la parte y/o producto en garantía y facturarla/o. El Distribuidor recibirá un crédito igual a la factura sólo después de que se haya devuelto el producto con pago previo y con verificación de defecto. LAS CONDICIONES DE LA GARANTÍA DE Fantech NO CONTEMPLAN EL REEMPLAZO SIN CARGO ANTES DE REALIZAR LA INSPECCIÓN PARA DETECTAR DEFECTOS. LOS REEMPLAZOS EMITIDOS ANTES DE INSPECCIONAR POR DEFECTOS SON FACTURADOS, Y EL CRÉDITO ESTÁ A LA ESPERA DE INSPECCIÓN DEL MATERIAL DEVUELTO. EL MATERIAL DEFECTUOSO DEVUELTO POR LOS USUARIOS FINALES NO DEBERÁ SER REEMPLAZADO POR EL DISTRIBUIDOR SIN CARGO PARA EL USUARIO FINAL, YA QUE EL CRÉDITO DE LA CUENTA DEL DISTRIBUIDOR ESTARÁ A LA ESPERA DE INSPECCIÓN Y VERIFICACIÓN DEL DEFECTO REAL POR Fantech. LAS SIGUIENTES GARANTÍAS NO SE APLICAN: • Daños durante el envío, ya sean encubiertos o visibles. Se deberá presentar el reclamo a la compañía transportadora. • Daños ocasionados por cableado o instalación indebidos. • Daños o fallas causados por hechos fortuitos, u ocasionados por procedimientos impropios por parte del usuario, tales como: 1. Mantenimiento indebido 2. Uso indebido, abuso, uso anormal o accidente y 3. Tensión o corriente eléctrica incorrecta. • Remoción o modificación realizada al número de control del rótulo de Fantech o de la fecha de fabricación. • Toda otra garantía, expresa, implícita o escrita, daños y perjuicios, pérdida de propiedad, de ingresos, o de beneficios, o costo de remoción, instalación o reinstalación por incumplimiento de la garantía. VALIDACIÓN DE LA GARANTÍA • El usuario debe conservar una copia de la constancia de compraventa para verificar la fecha de compra. • Estas garantías le otorgan derechos legales específicos, y están sujetas a una legislación aplicable para protección del consumidor. Usted puede tener derechos adicionales que varían de estado en estado. Limitacion de Garantia y Responsabilidad Civil Esta garantía no cubre ningún producto o pieza de Fantech que haya fallado por mala instalación, abuso, conexión eléctrica incorrecta o por alteraciones hechas por terceros, o por utilización bajo condiciones anormales de operación, o por aplicación incorrecta del producto o de las piezas. Nosotros no aprobamos el pago de ninguna reparación que no se haya realizado por nosotros o por nuestro agente autorizado previo consentimiento por escrito. Lo que antecede constituirá nuestra única y exclusiva garantía y nuestra única y exclusiva responsabilidad; y obra en lugar de cualquier otra garantía, ya sea escrita, verbal, tácita o estatutaria. No hay ninguna garantía que vaya más allá de lo que está descrito en esta página. Bajo ninguna circunstancia responderá Fantech, ya sea por incumplimiento de contrato o garantía ni por alegada negligencia, defecto, consejos incorrectos u otra causa, por daños especiales o consiguientes, incluso, pero no de manera única, pérdida de ganancias o ingresos, equipo cesante o cualquier otra pérdida relativa a equipos asociados; el costo del capital, costo de equipos, instalaciones o servicios sustitutos, tiempo ocioso o reclamos de clientes por compras incurridas por tales daños. Fantech ni asume ni autoriza a ninguna persona a que asuma a su nombre ninguna otra responsabilidad relativa a la venta de productos o piezas. Debido a que algunos distritos jurisdiccionales no permiten la exclusión o limitación por daños incidentales o consiguientes, puede que las limitaciones y limitaciones antes descritas no lo afe cten a Ud. Advertencia Aunque los productos de Fantech están diseñados y son fabricados para un rendimiento seguro, no garantizamos que estén libres de defectos al 100%. Hasta productos confiables a veces fallan; y el usuario debe reconocer esta posibilidad. Si estos productos se utilizan en un sistema de ventilación vital en donde una falla pudiera dar lugar a pérdidas o lesiones, el usuario debe disponer de una ventilación adecuada de reserva, ventilación natural suplemental, sistema de alarma de fallas, o expresar su voluntad de aceptar el riesgo de tales pérdidas o lesiones. fantech Fantech reserves the right to make technical changes. For updated documentation please refer to www.fantech.net Fantech se réserve le droit de faire des changements techniques. Pour de la documentation à jour, s'il vous plaît se référer au www.fantech.net Fantech se reserva el derecho de hacer modificaciones técnicas en cualquier momento. Para obtener la documentación actualizada, por favor consulte www.fantech.net Fantech® fantech
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Fantech PB270-2 Installation and Maintenance Manual

Tipo
Installation and Maintenance Manual
Este manual también es adecuado para

en otros idiomas