4
5 5
Shingle Application:
These shingles are applied with a
6
1
⁄2" offset, with 5
5
⁄8" exposure, over
prepared roof deck, starting at the
bottom of the roof and working across
and up. This will blend shingles from
one bundle into the next and minimize
any normal shade variation. Application
with offsets of 4" or 8" are also
acceptable.
Caution must be exercised to assure
that end joints are no closer than 2"
from fastener in the shingle below
and that side laps are no less than
4" in succeeding courses. Refer to
course application steps for specific
instructions.
Starter Course:
Use an Owens Corning
®
Starter
shingle product or trim 5
5
⁄8" from the
starter course shingle. Trim 6
1
⁄2" off the
rake of the starter course shingle and
flush with the drip edge along the rake
and eaves edge, and continue across
the roof. Use 5 fasteners for each
shingle, placed 2" to 3" up from eaves
edge. See Fig. 5. (If no drip edge
is used, shingles must extend a
minimum of
1
⁄2" and no more than
1" from rake and eaves edge.)
First Course:
Apply first course starting with the
full shingle even with the starter
course. See Fig. 5A. Fasten securely
according to fastening instructions.
See Fig. 4.
Second Course:
Remove 6
1
⁄2" from the left end of this
shingle and apply the remaining piece
over and above the first course shingle
and flush with edge of the first course
with 5
5
⁄8" exposure. See Fig. 5B.
Fasten securely according to fastening
instructions. See Fig. 4.
Third Course:
Remove 13" from the left end of this
shingle and apply the remaining piece
over and above the second course
shingle flush with edge of the second
course with 5
5
⁄8" exposure. See
Fig. 5C. Fasten securely according
to fastening instructions. See Fig. 4.
(continued on next page)
Instalación de las tejas:
Estas tejas se instalan con un
desplazamiento de 6
1
⁄2 pulg., con
una superficie expuesta de 5
5
⁄8
pulg., sobre plataformas de techos
preparadas. La colocación comienza
por la parte inferior del techo y se
realiza en forma transversal hacia
arriba. De esta manera, las tejas de
un paquete se mezclan con las del
siguiente y se reducen al mínimo las
variaciones normales de tonalidad.
También se pueden instalar tejas con
un desplazamiento de 4 ó 8 pulg.
Asegúrese de que las uniones de los
extremos no se encuentren a menos
de 2 pulg. del sujetador de la teja
que se encuentra más abajo, y que
las superposiciones laterales no sean
de menos de 4 pulg. en las hileras
siguientes. Consulte los pasos de
instalación de hileras para ver las
instrucciones específicas.
Hilera inicial:
Utilice un rollo de inicio o corte
5
5
⁄8 pulg. de la teja de la hilera inicial.
Corte 6
1
⁄2 pulg. desde la viga inclinada
en la teja de la hilera inicial y extienda
más allá de la viga inclinada y el
borde del alero, y continúe a lo ancho
del techo. Utilice 5 sujetadores para
cada teja, colocados a una distancia
de entre 2 y 3 pulg. del borde del
alero. Ver la Fig. 5. (Si no utiliza un
borde de goteo, las tejas deben
extenderse un mínimo de
1
⁄2 pulg.
y un máximo de 1 pulg. de la viga
inclinada y el borde del alero.)
Primera hilera:
Coloque la primera hilera comenzando
con la teja entera alineada con la hilera
inicial. Ver la Fig. 5A. Sujete firmemente
de acuerdo con las instrucciones de
sujeción. Ver la Fig. 4.
Segunda hilera:
Quite 6
1
⁄2" pulg. del borde izquierdo
de esta teja y aplique la pieza restante
sobre y por encima de la teja de la
primera hilera y al ras del borde de
la primera hilera, con 5
5
⁄8 pulg. de
exposición. Ver la Fig. 5B. Sujete
firmemente de acuerdo con las
instrucciones de sujeción. Ver la Fig. 4.
Tercera hilera:
Quite 13 pulg. del borde izquierdo de
esta teja y aplique la pieza restante
sobre y por encima de la teja de la
segunda hilera y al ras del borde de
la segunda hilera, con 5
5
⁄8 pulg. de
exposición. Ver la Fig. 5C. Sujete
firmemente de acuerdo con las
instrucciones de sujeción. Ver la Fig. 4.
(continúa en la página siguiente)
Vista lateral de la teja
Shingle Side View
Properly Driven Improperly Driven
1/2"
3/4" min.
Decking
Shingle
3/8" min.
diameter
1/4"
Bien colocado Mal colocado
1/2 pulg.
3/4 pulg. mín.
diámetro mín.
3/8 pulg.
1/4 pulg.
Entablonado
Teja
12"
1"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
1"
12"
4 Nail Pattern
Esquema con 4 clavos
Fig. 3
Pendiente baja del revestimiento
Underlayment Low Slope
Fig. 4
Esquema de instalación estándar
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Nails
Clavos
Fig. 5C
Instalación de tejas
Shingle Application
Third Course
Tercera hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 13"
from
left edge
Cortar 13 pulg.
del borde izquierdo
13"
Tercera hilera
3rd Course
Fig. 5E
Instalación de tejas
Shingle Application
Fifth Course
Quinta hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
5 5/8"
Trim 26" from left edge
Cortar 26 pulg. del
borde izquierdo
26"
Quinta hilera
5th Course
Starter Course
Hilera inicial
Instalación de tejas
Rake Edge
Borde de viga
inclinada
6 1/2"
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
Trim 5 5/8"
from front edge
Cortar 5 5/8 pulg. del
borde delantero
Fig. 5B
Instalación de tejas
Shingle Application
Second Course
Segunda hilera
Rake Edge
Borde de viga
inclinada
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
6 1/2"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
Segunda hilera
2nd Course
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Fig. 5D
Instalación de tejas
Shingle Application
Fourth Course
Cuarta hilera
Rake Edge
Borde de viga
inclinada
Trim
19 1/2"
from left edge
Cortar 19 1/2 pulg.
del borde izquierdo
19 1/2"
Cuarta hilera
4th Course
Fig. 5F
Instalación de tejas
Shingle Application
Sixth Course
Sexta hilera
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 32 1/2" from left edge
Cortar 32 1/2 pulg. del
borde izquierdo
32 1/2"
Sexta hilera
6th Course
Fig. 8
Instalación de caballetes y cumbreras
Hip & Ridge Application
Prevailing Wind Direction
Dirección del viento predominante
Exposure
Exposición
Fig. 5G
Instalación de tejas
Shingle Application
Succeeding Courses
Hileras siguientes
Séptima hilera
7th Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
First Course
Rake Edge
Primera hilera
Borde de viga
inclinada
5 5/8"
13 1/4"
Primera hilera
1st Course
Fig. 5A
Instalación de tejas
Shingle Application
Fig. 4B
Esquema de instalación en pendientes pronunciadas o mansardas
Fig. 4A
Esquema de instalación con seis clavos
Six Nail Fastening Pattern
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
6 Fasteners
6 sujetadores
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
Nails
Clavos
Fig. 6
Construcción del valle con corte cerrado
Closed-Cut Valley Construction
Centerline
Línea central
Valley Liner
Revestimiento del valle
6" Min.
6 pulg. de mínimo
2"
2 pulg.
Extra Nail
Clavo adicional
Asphalt Roof Cement
Cemento asfaltado para techos
Clip Corner
Cortar esquina
Eaves flashing
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Línea de la pared
24 pulg. más allá de la
línea de la pared interior
Tapajuntas para aleros
Wall line
24" Beyond interior
wall line
Slopes 4" in 12" or more
Clavos
Borde de goteo
sobre el
revestimiento en la
cornisa del tímpano
4" min. end lap
Pendientes de 4 pulg. cada 12 pulg. o más
Nails
Drip edge
over
underlayment
at rake edge
Superposición
final. 4 pulg. mínimo
Uniones verticales
a 6 pies de mínimo
Vertical seams
6' min.
Fig. 1
Tapajuntas especial para aleros
Specialty Eave Flashing
Fig. 2
Pendiente estándar del revestimiento
Underlayment Standard Slope
Underlayment
Revestimiento
Fig. 7
Tapajuntas escalonado
Step Flashing
5"
5"
Clavar el tapajuntas
al techo
Nail flashing to roof
Four 1" Spots of Asphalt Cement
Cuatro puntos de cemento asfáltico de 1 pulg.
Tapajuntas de metal
10 pulg. de longitud x 2 pulg. más de ancho
que la exposición
Exposure + 2"
Exposición + 2 pulg.
2" Top Lap
Empalme superior de 2 pulg.
Metal Flashing
10" long x 2" wider than exposure
Primera hilera e hileras siguientes tienen 36 pulg.
de ancho con una superposición de 19 pulg.
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
Borde de
goteo
Borde
de goteo
Superposición final,
12 pulg.
Hilera inicial,
19 pulg.
19"
19"
17"
36"
19"
Línea de la pared
(B) First and succeeding courses
are 36" wide with 19" lap
Drip edge
Drip
edge
12" End lap
(A) 19"
Starter strip
19"
Wall line
(C)
(C)
(C)
(B)
(A)
Revestimiento
sobre borde de
goteo en el alero
Superposición
superior, 2 pulg.
Underlayment over
drip edge at eave
2
"
overlap
Underlayment
Revestimiento
Underlayment
Revestimiento
Underlayment
Revestimiento
Fig. 3A
Pendiente baja del revestimiento
Underlayment Low Slope
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
WeatherLock
®
sobre borde de
goteo en el alero
Clavos
Borde de goteo
sobre WeatherLock
®
en la cornisa
del tímpano
Superposición
superior, 3 pulg.
6" min. end lap
WeatherLock
®
over drip edge
at eave
Nails
Drip edge
over
WeatherLock
®
at rake edge
3"
Top lap
Superposición
final, 6 pulg. mín.
Uniones verticales
a 6 pies mín.
Vertical seams
6' min.
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Vista lateral de la teja
Shingle Side View
Properly Driven Improperly Driven
1/2"
3/4" min.
Decking
Shingle
3/8" min.
diameter
1/4"
Bien colocado Mal colocado
1/2 pulg.
3/4 pulg. mín.
diámetro mín.
3/8 pulg.
1/4 pulg.
Entablonado
Teja
12"
1"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
1"
12"
4 Nail Pattern
Esquema con 4 clavos
Fig. 3
Pendiente baja del revestimiento
Underlayment Low Slope
Fig. 4
Esquema de instalación estándar
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Nails
Clavos
Fig. 5C
Instalación de tejas
Shingle Application
Third Course
Tercera hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 13"
from
left edge
Cortar 13 pulg.
del borde izquierdo
13"
Tercera hilera
3rd Course
Fig. 5E
Instalación de tejas
Shingle Application
Fifth Course
Quinta hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
5 5/8"
Trim 26" from left edge
Cortar 26 pulg. del
borde izquierdo
26"
Quinta hilera
5th Course
Starter Course
Hilera inicial
Fig. 5
Instalación de tejas
Shingle Application
Rake Edge
Borde de viga
inclinada
6 1/2"
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
Trim 5 5/8"
from front edge
Cortar 5 5/8 pulg. del
borde delantero
Fig. 5B
Instalación de tejas
Second Course
Segunda hilera
Rake Edge
Borde de viga
inclinada
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
6 1/2"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
Segunda hilera
2nd Course
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Fig. 5D
Instalación de tejas
Shingle Application
Fourth Course
Cuarta hilera
Rake Edge
Borde de viga
inclinada
Trim
19 1/2"
from left edge
Cortar 19 1/2 pulg.
del borde izquierdo
19 1/2"
Cuarta hilera
4th Course
Fig. 5F
Instalación de tejas
Shingle Application
Sixth Course
Sexta hilera
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 32 1/2" from left edge
Cortar 32 1/2 pulg. del
borde izquierdo
32 1/2"
Sexta hilera
6th Course
Fig. 8
Instalación de caballetes y cumbreras
Hip & Ridge Application
Prevailing Wind Direction
Dirección del viento predominante
Exposure
Exposición
Fig. 5G
Instalación de tejas
Shingle Application
Succeeding Courses
Hileras siguientes
Séptima hilera
7th Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
First Course
Rake Edge
Primera hilera
Borde de viga
inclinada
5 5/8"
13 1/4"
Primera hilera
1st Course
Fig. 5A
Instalación de tejas
Shingle Application
Fig. 4B
Esquema de instalación en pendientes pronunciadas o mansardas
Fig. 4A
Esquema de instalación con seis clavos
Six Nail Fastening Pattern
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
6 Fasteners
6 sujetadores
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
Nails
Clavos
Fig. 6
Construcción del valle con corte cerrado
Closed-Cut Valley Construction
Centerline
Línea central
Valley Liner
Revestimiento del valle
6" Min.
6 pulg. de mínimo
2"
2 pulg.
Extra Nail
Clavo adicional
Asphalt Roof Cement
Cemento asfaltado para techos
Clip Corner
Cortar esquina
Eaves flashing
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Línea de la pared
24 pulg. más allá de la
línea de la pared interior
Tapajuntas para aleros
Wall line
24" Beyond interior
wall line
Slopes 4" in 12" or more
Clavos
Borde de goteo
sobre el
revestimiento en la
cornisa del tímpano
4" min. end lap
Pendientes de 4 pulg. cada 12 pulg. o más
Nails
Drip edge
over
underlayment
at rake edge
Superposición
final. 4 pulg. mínimo
Uniones verticales
a 6 pies de mínimo
Vertical seams
6' min.
Fig. 1
Tapajuntas especial para aleros
Specialty Eave Flashing
Fig. 2
Pendiente estándar del revestimiento
Underlayment Standard Slope
Underlayment
Revestimiento
Fig. 7
Tapajuntas escalonado
Step Flashing
5"
5"
Clavar el tapajuntas
al techo
Nail flashing to roof
Four 1" Spots of Asphalt Cement
Cuatro puntos de cemento asfáltico de 1 pulg.
Tapajuntas de metal
10 pulg. de longitud x 2 pulg. más de ancho
que la exposición
Exposure + 2"
Exposición + 2 pulg.
2" Top Lap
Empalme superior de 2 pulg.
Metal Flashing
10" long x 2" wider than exposure
Primera hilera e hileras siguientes tienen 36 pulg.
de ancho con una superposición de 19 pulg.
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
Borde de
goteo
Borde
de goteo
Superposición final,
12 pulg.
Hilera inicial,
19 pulg.
19"
19"
17"
36"
19"
Línea de la pared
(B) First and succeeding courses
are 36" wide with 19" lap
Drip edge
Drip
edge
12" End lap
(A) 19"
Starter strip
19"
Wall line
(C)
(C)
(C)
(B)
(A)
Revestimiento
sobre borde de
goteo en el alero
Superposición
superior, 2 pulg.
Underlayment over
drip edge at eave
2
"
overlap
Underlayment
Revestimiento
Underlayment
Revestimiento
Underlayment
Revestimiento
Fig. 3A
Pendiente baja del revestimiento
Underlayment Low Slope
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
WeatherLock
®
sobre borde de
goteo en el alero
Clavos
Borde de goteo
sobre WeatherLock
®
en la cornisa
del tímpano
Superposición
superior, 3 pulg.
6" min. end lap
WeatherLock
®
over drip edge
at eave
Nails
Drip edge
over
WeatherLock
®
at rake edge
3"
Top lap
Superposición
final, 6 pulg. mín.
Uniones verticales
a 6 pies mín.
Vertical seams
6' min.
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Vista lateral de la teja
Shingle Side View
Properly Driven Improperly Driven
1/2"
3/4" min.
Decking
Shingle
3/8" min.
diameter
1/4"
Bien colocado Mal colocado
1/2 pulg.
3/4 pulg. mín.
diámetro mín.
3/8 pulg.
1/4 pulg.
Entablonado
Teja
12"
1"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
1"
12"
4 Nail Pattern
Esquema con 4 clavos
Fig. 3
Pendiente baja del revestimiento
Underlayment Low Slope
Fig. 4
Esquema de instalación estándar
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Nails
Clavos
Fig. 5C
Instalación de tejas
Third Course
Tercera hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 13"
from
left edge
Cortar 13 pulg.
del borde izquierdo
13"
Tercera hilera
3rd Course
Fig. 5E
Instalación de tejas
Shingle Application
Fifth Course
Quinta hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
5 5/8"
Trim 26" from left edge
Cortar 26 pulg. del
borde izquierdo
26"
Quinta hilera
5th Course
Starter Course
Hilera inicial
Fig. 5
Instalación de tejas
Shingle Application
Rake Edge
Borde de viga
inclinada
6 1/2"
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
Trim 5 5/8"
from front edge
Cortar 5 5/8 pulg. del
borde delantero
Fig. 5B
Instalación de tejas
Shingle Application
Second Course
Segunda hilera
Rake Edge
Borde de viga
inclinada
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
6 1/2"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
Segunda hilera
2nd Course
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Fig. 5D
Instalación de tejas
Shingle Application
Fourth Course
Cuarta hilera
Rake Edge
Borde de viga
inclinada
Trim
19 1/2"
from left edge
Cortar 19 1/2 pulg.
del borde izquierdo
19 1/2"
Cuarta hilera
4th Course
Fig. 5F
Instalación de tejas
Shingle Application
Sixth Course
Sexta hilera
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 32 1/2" from left edge
Cortar 32 1/2 pulg. del
borde izquierdo
32 1/2"
Sexta hilera
6th Course
Fig. 8
Instalación de caballetes y cumbreras
Hip & Ridge Application
Prevailing Wind Direction
Dirección del viento predominante
Exposure
Exposición
Fig. 5G
Instalación de tejas
Shingle Application
Succeeding Courses
Hileras siguientes
Séptima hilera
7th Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
First Course
Rake Edge
Primera hilera
Borde de viga
inclinada
5 5/8"
13 1/4"
Primera hilera
1st Course
Fig. 5A
Instalación de tejas
Shingle Application
Fig. 4B
Esquema de instalación en pendientes pronunciadas o mansardas
Fig. 4A
Esquema de instalación con seis clavos
Six Nail Fastening Pattern
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
6 Fasteners
6 sujetadores
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
Nails
Clavos
Fig. 6
Construcción del valle con corte cerrado
Closed-Cut Valley Construction
Centerline
Línea central
Valley Liner
Revestimiento del valle
6" Min.
6 pulg. de mínimo
2"
2 pulg.
Extra Nail
Clavo adicional
Asphalt Roof Cement
Cemento asfaltado para techos
Clip Corner
Cortar esquina
Eaves flashing
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Línea de la pared
24 pulg. más allá de la
línea de la pared interior
Tapajuntas para aleros
Wall line
24" Beyond interior
wall line
Slopes 4" in 12" or more
Clavos
Borde de goteo
sobre el
revestimiento en la
cornisa del tímpano
4" min. end lap
Pendientes de 4 pulg. cada 12 pulg. o más
Nails
Drip edge
over
underlayment
at rake edge
Superposición
final. 4 pulg. mínimo
Uniones verticales
a 6 pies de mínimo
Vertical seams
6' min.
Fig. 1
Tapajuntas especial para aleros
Specialty Eave Flashing
Fig. 2
Pendiente estándar del revestimiento
Underlayment Standard Slope
Underlayment
Revestimiento
Fig. 7
Tapajuntas escalonado
Step Flashing
5"
5"
Clavar el tapajuntas
al techo
Nail flashing to roof
Four 1" Spots of Asphalt Cement
Cuatro puntos de cemento asfáltico de 1 pulg.
Tapajuntas de metal
10 pulg. de longitud x 2 pulg. más de ancho
que la exposición
Exposure + 2"
Exposición + 2 pulg.
2" Top Lap
Empalme superior de 2 pulg.
Metal Flashing
10" long x 2" wider than exposure
Primera hilera e hileras siguientes tienen 36 pulg.
de ancho con una superposición de 19 pulg.
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
Borde de
goteo
Borde
de goteo
Superposición final,
12 pulg.
Hilera inicial,
19 pulg.
19"
19"
17"
36"
19"
Línea de la pared
(B) First and succeeding courses
are 36" wide with 19" lap
Drip edge
Drip
edge
12" End lap
(A) 19"
Starter strip
19"
Wall line
(C)
(C)
(C)
(B)
(A)
Revestimiento
sobre borde de
goteo en el alero
Superposición
superior, 2 pulg.
Underlayment over
drip edge at eave
2
"
overlap
Underlayment
Revestimiento
Underlayment
Revestimiento
Underlayment
Revestimiento
Fig. 3A
Pendiente baja del revestimiento
Underlayment Low Slope
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
WeatherLock
®
sobre borde de
goteo en el alero
Clavos
Borde de goteo
sobre WeatherLock
®
en la cornisa
del tímpano
Superposición
superior, 3 pulg.
6" min. end lap
WeatherLock
®
over drip edge
at eave
Nails
Drip edge
over
WeatherLock
®
at rake edge
3"
Top lap
Superposición
final, 6 pulg. mín.
Uniones verticales
a 6 pies mín.
Vertical seams
6' min.
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Vista lateral de la teja
Shingle Side View
Properly Driven Improperly Driven
1/2"
3/4" min.
Decking
Shingle
3/8" min.
diameter
1/4"
Bien colocado Mal colocado
1/2 pulg.
3/4 pulg. mín.
diámetro mín.
3/8 pulg.
1/4 pulg.
Entablonado
Teja
12"
1"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
1"
12"
4 Nail Pattern
Esquema con 4 clavos
Fig. 3
Pendiente baja del revestimiento
Underlayment Low Slope
Fig. 4
Esquema de instalación estándar
Standard Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Nails
Clavos
Fig. 5C
Instalación de tejas
Shingle Application
Third Course
Tercera hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 13"
from
left edge
Cortar 13 pulg.
del borde izquierdo
13"
Tercera hilera
3rd Course
Fig. 5E
Instalación de tejas
Shingle Application
Fifth Course
Quinta hilera
Línea de tiza horizontal
Rake Edge
Borde de viga
inclinada
Horizontal chalk line
5 5/8"
Trim 26" from left edge
Cortar 26 pulg. del
borde izquierdo
26"
Quinta hilera
5th Course
Starter Course
Hilera inicial
Fig. 5
Instalación de tejas
Shingle Application
Rake Edge
Borde de viga
inclinada
6 1/2"
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
Trim 5 5/8"
from front edge
Cortar 5 5/8 pulg. del
borde delantero
Fig. 5B
Instalación de tejas
Shingle Application
Second Course
Segunda hilera
Rake Edge
Borde de viga
inclinada
5 5/8"
Trim 6 1/2"
from left edge
Cortar 6 1/2 pulg. del
borde izquierdo
6 1/2"
5 5/8" Exposure
Exposición de 5 5/8 pulg.
Segunda hilera
2nd Course
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Fig. 5D
Instalación de tejas
Shingle Application
Fourth Course
Cuarta hilera
Rake Edge
Borde de viga
inclinada
Trim
19 1/2"
from left edge
Cortar 19 1/2 pulg.
del borde izquierdo
19 1/2"
Cuarta hilera
4th Course
Fig. 5F
Instalación de tejas
Shingle Application
Sixth Course
Sexta hilera
Línea de tiza horizontal
Horizontal chalk line
5 5/8"
Trim 32 1/2" from left edge
Cortar 32 1/2 pulg. del
borde izquierdo
32 1/2"
Sexta hilera
6th Course
Fig. 8
Instalación de caballetes y cumbreras
Hip & Ridge Application
Prevailing Wind Direction
Dirección del viento predominante
Exposure
Exposición
Fig. 5G
Instalación de tejas
Shingle Application
Succeeding Courses
Hileras siguientes
Séptima hilera
7th Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
Sexta hilera
6th Course
Quinta hilera
5th Course
Cuarta hilera
4th Course
Tercera hilera
3rd Course
Segunda hilera
2nd Course
Primera hilera
1st Course
First Course
Rake Edge
Primera hilera
Borde de viga
inclinada
5 5/8"
13 1/4"
Primera hilera
1st Course
Instalación de tejas
Shingle Application
Fig. 4B
Esquema de instalación en pendientes pronunciadas o mansardas
Fig. 4A
Esquema de instalación con seis clavos
Six Nail Fastening Pattern
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
6 Fasteners
6 sujetadores
5 5/8"
Exposure
Exposición de
5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
5 5/8" Exposure
Exposición de 5 5/8 pulg.
12"
1"
1"
12"
6 Nail Pattern
Esquema con 6 clavos
Nails
Clavos
Fig. 6
Construcción del valle con corte cerrado
Closed-Cut Valley Construction
Centerline
Línea central
Valley Liner
Revestimiento del valle
6" Min.
6 pulg. de mínimo
2"
2 pulg.
Extra Nail
Clavo adicional
Asphalt Roof Cement
Cemento asfaltado para techos
Clip Corner
Cortar esquina
Eaves flashing
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo
Línea de la pared
24 pulg. más allá de la
línea de la pared interior
Tapajuntas para aleros
Wall line
24" Beyond interior
wall line
Slopes 4" in 12" or more
Clavos
Borde de goteo
sobre el
revestimiento en la
cornisa del tímpano
4" min. end lap
Pendientes de 4 pulg. cada 12 pulg. o más
Nails
Drip edge
over
underlayment
at rake edge
Superposición
final. 4 pulg. mínimo
Uniones verticales
a 6 pies de mínimo
Vertical seams
6' min.
Fig. 1
Tapajuntas especial para aleros
Specialty Eave Flashing
Fig. 2
Pendiente estándar del revestimiento
Underlayment Standard Slope
Underlayment
Revestimiento
Fig. 7
Tapajuntas escalonado
Step Flashing
5"
5"
Clavar el tapajuntas
al techo
Nail flashing to roof
Four 1" Spots of Asphalt Cement
Cuatro puntos de cemento asfáltico de 1 pulg.
Tapajuntas de metal
10 pulg. de longitud x 2 pulg. más de ancho
que la exposición
Exposure + 2"
Exposición + 2 pulg.
2" Top Lap
Empalme superior de 2 pulg.
Metal Flashing
10" long x 2" wider than exposure
Primera hilera e hileras siguientes tienen 36 pulg.
de ancho con una superposición de 19 pulg.
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
Borde de
goteo
Borde
de goteo
Superposición final,
12 pulg.
Hilera inicial,
19 pulg.
19"
19"
17"
36"
19"
Línea de la pared
(B) First and succeeding courses
are 36" wide with 19" lap
Drip edge
Drip
edge
12" End lap
(A) 19"
Starter strip
19"
Wall line
(C)
(C)
(C)
(B)
(A)
Revestimiento
sobre borde de
goteo en el alero
Superposición
superior, 2 pulg.
Underlayment over
drip edge at eave
2
"
overlap
Underlayment
Revestimiento
Underlayment
Revestimiento
Underlayment
Revestimiento
Fig. 3A
Pendiente baja del revestimiento
Underlayment Low Slope
Slopes 2" in 12" to less than 4" in 12"
Pendientes de 2 pulg. cada 12 pulg., hasta menos de 4 pulg. cada 12 pulg.
WeatherLock
®
sobre borde de
goteo en el alero
Clavos
Borde de goteo
sobre WeatherLock
®
en la cornisa
del tímpano
Superposición
superior, 3 pulg.
6" min. end lap
WeatherLock
®
over drip edge
at eave
Nails
Drip edge
over
WeatherLock
®
at rake edge
3"
Top lap
Superposición
final, 6 pulg. mín.
Uniones verticales
a 6 pies mín.
Vertical seams
6' min.
Self adhered membrane
Impermeabilizante autoadhesivo
Self-adhered membrane
Impermeabilizante autoadhesivo