Eaton 93PS UPS
8-40 kW
Document ID
Eaton 91PS/93PS UPS
750 mm
480 mm
1750 mm
1300 mm
335 mm
750 mm
645 mm
335 mm
750 mm
2
1
6.1
5.1
5.2
%
100% 0 % 20 % 40% 60% 80 %
95 %
0 ºC 10 ºC 20 ºC 30 ºC 40 ºC 50 ºC -10 ºC
≤ 40 ºC
DOWNLOAD FULL USER’S AND INSTALLATION
GUIDE AT WWW.EATON.COM/91PSAND93PS
REV2 P-164000576
TB20
PE
L1
L1
L3
L1
L3
L3
N
L2
N
L2
N
L2
+
X1 X2 X3 X4
N L N L
+ -
X1
TB20
X2 X3 X4
L1 L2 L3
PE
6.2
3
4.1
4.2
1
A B C
1
5
5
9 14 35 2 1
46
7 8 10 11 12 13 15 16
8
9
1
2
3
4
5
6
14
1516
10
11
7
12
13
3
4
4
7
8
8
6
6
2
2
7
3
93PS 40 kW 93PS 40 kW
91PS 30 kW 91PS 30 kW
BLUE BEADS IN
ARROW INDICATES
CONTAINER WAS
TIPPED OR
MISHANDLED
MADE IN U.S.A.
9.1
9.4
9.6
9.7
9.8
9.2
9.5
1
1
2
2
A
TB20
1
2
3
4
A
TB21
1
2
3
4
NO NC
1 2 3 4 1 2 3 4
NO NC
123
123
NC
NC
NO
NO
9.3
8.1
L1 L2 L3
N L
N L
X1 X2
X4
X3
+ -
PE
PE
(X1,X2)
PE
TB20
+ -
N L1 L2 L3
N L1 L2 L3
N L1 L2 L3
X3
TB20
PE
X2
X4 / -
X1
X4 / +
PE
(X1,X2)
PE
N L
X3
X4/+
X4/-
1 3 2 4
L1 L2 L3
N L
X1
X2
TB21TB20
PE
N L1 L2 L3
N L1 L2 L3
1 3
2 4
N L1 L2 L3
X3
TB21TB20
X2
X4 / -
X1
X4 / +
PE
8.2
7.1 7.2
10.1
13
12
11
10.2
10.3
10.5
10.4
1
2
3
<80°
5.1/5.2
1
CONTENTS
EN Safety and Installation Quick Guide
DE Schnellanleitung für Sicherheit und Installation
FR Guide rapide de sécurité et d’installation
FI Turvallisuus- ja asennuspikaopas
SV Snabbguide för säkerhet och installation
NO Hurtigveiledning for sikkerhets or installasjon
DA Hurtig sikkerheds- of installationsvejledning
RU Kpatkoe руководство по технике безопасности и установке
NL Verkorte handleidingvoor veiligheid en installatie
ES Guía de seguridad y de instalación rápida
CS Rychlá bezpečnostní a instalační příručka
PL Skrócona instrukcja bezpieczeństwa i montażu
IT Guida rapida all’installazione e informazioni sulla sicurezza
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
. . . . . . . . . . . . . . . . . . . . . . . . . . 52
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
. . . . . . . . . . 72
. . . . . . . . . . . . . . . . . . . . . . . 82
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
. . . . . . . . . . . . . . . . . . . . . . . . 112
. . . . . . . . . . . . . 122
1
DANGER
Important safety instructions!
Keep these instructions!
This document provides important safety instructions and a short instruction for how to
examine the UPS delivery and how to install the UPS. This quick guide is only meant to be
used as an installation checklist on site.
The intended audience of this document is experienced professionals who plan and do the
installation of the UPS.
DANGER
Before you do work on the UPS, read the full installation instructions provided in the
Eaton 91PS/93PS UPS 8-40 kW Users and Installation Guide.
The full instructions are available for download at www.eaton.com/91psand93ps.
Operations inside the UPS must be done by an authorized Eaton Customer Service
Engineer or by qualified service personnel authorized by Eaton. There are no user-
serviceable parts inside the UPS.
The UPS operates with mains, battery or bypass power. It contains components that carry
high currents and voltage. A properly installed enclosure is earthed and IP20 rated against
electrical shock and foreign objects. However, the UPS is a sophisticated power system
and only qualified personnel are allowed to install and service it.
DANGER
This UPS carries lethal voltages.
Batteries present a risk of electrical shock or burn from high short circuit current. Obey
the precautions.
Batteries may contain HIGH VOLTAGES, and CORROSIVE, TOXIC and EXPLOSIVE
substances. Because of the battery string the output receptacles may carry high voltage
even when the AC supply is not connected to the UPS. Read the shutdown instructions in
the Users and Installation Guide.
WARNING
The UPS is powered by its own energy source (batteries). The output terminals may be
energized even when the UPS is disconnected from an AC source. To reduce the risk of
fire or electric shock, install this UPS in a temperature and humidity controlled, indoor
environment that is free of conductive contaminants.
Do not stack the 91PS/93PS C-model UPS cabinet on top of any other similar cabinet(s).
Do not stack anything on the top of the 91PS/93PS UPS cabinet. If the 91PS/93PS C-
model UPS cabinet is installed on a shelf, use necessary supports to prevent the UPS
from tipping or dropping.
EN
2
WARNING
The ambient temperature must not exceed 40 °C (104 °F). Do not operate the UPS near
water or excessive humidity (95% maximum). The system is not intended for outdoor
use.
Before you start any installation or service work, make sure that all AC and DC power
sources are disconnected. Power may come from multiple sources. Also ensure system
grounding / PE continuity.
In a parallel system, the output terminals may be energized even when the UPS is turned
off.
Electric energy hazard. To avoid injury, do not attempt to alter any battery wiring or
connectors.
IMPORTANT: Make sure that you disconnect all battery strings before installation.
CAUTION
Only qualified service personnel knowledgeable of batteries and the required precautions
can do installation or service work on batteries. Installation and service work on batteries
is live-line working and requires the use of voltage tools. Keep unauthorized personnel
away from the batteries.
Before you install or replace batteries, consider all the warnings, cautions, and notes
concerning appropriate handling. Do not disconnect the batteries when the UPS is in the
Battery mode.
Make sure that your replacement batteries are of the same number and type as the
battery that was originally installed in the UPS. See more accurate instructions on the
UPS.
Before you connect or disconnect battery terminals, disconnect the charging source by
opening the corresponding battery circuit breaker.
Examine if the battery is inadvertently grounded. If it is, remove the source of the ground.
Contacting any part of a grounded battery can cause a risk of electric shock.
Discard batteries according to your local disposal requirements.
Do not discard batteries in a fire. When exposed to flame, batteries may explode.
To reduce the risk of a fire, connect only to a circuit that is provided with maximum input
circuit breaker current ratings in accordance with the national and local installation rules.
To ensure proper cooling airflow and to protect personnel from dangerous voltages inside
the unit, keep the UPS door closed and the front panels installed.
Do not install or operate the UPS system close to gas or electric heat sources.
Keep the operating environment within the parameters stated in this document. Keep the
surroundings of the UPS uncluttered, clean, and free from excess moisture.
Obey all DANGER, CAUTION, and WARNING notices affixed to the inside and outside of
the equipment.
EN
3
2
The Eaton® 91PS/93PS uninterruptible power supply (UPS) is a true online, continuous-
duty, transformerless, double-conversion, solid-state, single-phase (91PS) or three-phase
(93PS) system. It supplies conditioned and uninterruptible AC power to critical load and
protects it from power failures. Eaton 91PS/93PS output power ratings are based on 15 kW
or 20 kW rated uninterruptible power modules (UPMs).
91PS/93PS is also available as a C-model, which consist of the electrical part of the
91PS/93PS UPS 15/20 kW frame without the battery compartment.
Table 1. UPS cabinet ratings
UPS frame Picture
(Illustration 1)
Number of UPMs
Ratings
91PS 15 kW
A and B
1 8, 10, 15 kW
91PS 30 kW
C
1 or 2 8, 10, 15, 20, 30 kW
93PS 20 kW
A and B
1 8, 10, 15 or 20 kW
93PS 40 kW
C
1 or 2
8, 10, 15, 20, 30 or 40
kW
The main parts of the 91PS/93PS UPS 8-40 kW are shown in illustration 2. The main parts
are as follows:
1. Control panel
2. Door latch
3. Power module (UPM)
4. Internal battery (not in C-models)
5. Communications area
6. Input switch
7. Battery breaker
8. Maintenance bypass switch (optional)
.
DANGER
This UPS carries lethal voltages.
Operations inside the UPS must be done by an authorized Eaton Customer Service
Engineer or by qualified service personnel authorized by Eaton. There are no user-
serviceable parts inside the UPS.
For complete safety instructions, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and
Installation Guide.
The UPS must be installed according to the recommendations in the Eaton 91PS/93PS
UPS 8-40 kW Users and Installation Guide.
Use the following basic sequence of steps to install the UPS:
EN
4
1. Create an installation plan for the UPS system.
2. Prepare your site for the UPS system.
3. Inspect and unpack the UPS cabinet.
4. Unload and install the UPS cabinet and wire the system.
5. Complete the installation checklist.
6. Have authorized service personnel perform the preliminary operational checks and start
-
up.
NOTE: Startup and operational checks must be performed by an authorized Eaton
Customer Service Engineer or by qualified service personnel authorized by Eaton, or the
warranty terms specified in the Warranty become void.
Before you install the UPS system, read and understand how these instructions apply to
the system that you are going to install. Use the procedures and illustrations provided to
create a logical plan for installing the system.
For the UPS system to operate at peak efficiency, the installation site must meet the
environmental parameters outlined in the Eaton 91PS/93PS UPS 8-40 kW Users and
Installation Guide.
The installation environment must meet the UPS weight and size requirements provided in
Tables 2 and 3.
The dimensions of the UPS cabinet are shown in illustration 1. Note that the depth
dimension (750 mm) includes cable glands.
Table 2. UPS cabinet weights with cardboard packaging
C-model 8-20 kW
(Illustration 1,
picture A)
15/20 kW frame*
(Illustration 1,
picture B)
30/40 kW frame*
(Illustration 1,
picture C)
Shipping weight
98 kg
293 kg
558 kg
Installed weight 86 kg
280 kg
532 kg
Floor loading 310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Maximum internal batteries are included with all models.
The UPS cabinets use forced air cooling to regulate internal component temperature. By
default, air inlets are in the front of the cabinet and outlets are in the back, see
illustration 3. Allow clearance in front of and behind each cabinet for proper air circulation.
Make sure that the cooling air that enters the UPS does not exceed +40 °C. For ventilation
requirements, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide.
EN
5
Table 3. UPS cabinet minimum clearances
15/20 kW frame
(Illustration 1,
pictures A and B)
30/40 kW frame
(Illustration 1,
picture C)
From the top of the cabinet 500 mm 500 mm
From the front of the cabinet
500 mm 650 mm
From the back of the cabinet
150 mm 250 mm
From the side of the cabinet 0 mm 0 mm
The recommended ambient operating temperature and humidity for the UPS system is
shown in illustrations 4.1 and 4.2. An ambient temperature from +20 °C to +25 °C is
recommended to achieve a long life of VRLA batteries.
Table 4. Minimum recommended multi-core cable and fuse sizes for rectifier and bypass input and
UPS output cables (3-phase input, 3-phase output models)
93PS UPS rating (kW) 8 10 15 20 30 40
Cable [mm
2
] 4*2.5 4*4 4*10 4*10 4*16 4*25
Rectifier fuse [A]
20 20 32 40 63 80
Bypass fuse [A] 20 20 32 40 63 80
PE cable [mm
2
] 1*6 1*6 1*10 1*10 1*16 1*16
Maximum conductor cross
section
20 kW frame and 20 kW C-model: solid wire 16 mm
2
, stranded wire
with ferrule: 10 mm
2
40kW frame: solid wire 70 mm
2
, stranded wire with ferrule: 50 mm
2
Table 5. Minimum recommended multi-core cable and fuse sizes for rectifier and bypass input and
UPS output cables (3-phase input, 1-phase output models)
91PS UPS rating (kW) 8 10 15 20 30
Rectifier cable [mm
2
]
2,5 4 10 10 16
Rectifier fuse [A] 20 20 32 40 63
Bypass, output cable
[mm
2
]
10 16 25 35 70
Bypass fuse [A]
50 63 80 100 160
PE cable [mm
2
] 10 16 16 16 35
Maximum conductor cross
section, 15 kW frame and
15 kW C-model
Rectifier: solid wire 16 mm
2
, stranded wire with ferrule:
10 mm
2
Bypass/output: solid wire 70 mm
2
, stranded wire with
ferrule: 50 mm
2
EN
6
91PS UPS rating (kW) 8 10 15 20 30
Maximum conductor cross
section, 30 kW frame
Rectifier: solid wire 70 mm
2
, stranded wire with ferrule:
50 mm
2
Bypass/output: solid wire 95 mm
2
, stranded wire with
ferrule: 95 mm
2
CAUTION
Make sure that prospective short-circuit current resulting at the UPS input terminals is
equal or less than conditional short-circuit current declared on the ratings label of the
UPS.
Table 6. Minimum recommended cable and fuse sizes for external battery bank
UPS rating (kW) 8 10 15 20 30 40
Pos. & neg. line [mm
2
] 1*16 1*16 1*16 1*16 1*35 1*35
Battery fuse [A]
63 63 63 63 160 160
PE cable [mm
2
] 1*16 1*16 1*16 1*16 1*16 1*16
Maximum conductor cross
section
15/20 kW frame, C-model and 30/40 kW frame with separate
battery: solid wire: 25 mm
2
, stranded wire with ferrule: 16 mm
2
30/40 kW frame with common battery: solid wire: 90 mm
2
, stranded
wire with ferrule: 70 mm
2
For information on rated and maximum currents for rated power and voltage, refer to the
Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide.
For the external separate battery option, there are separate terminals for both battery
banks (cabinets), refer to Section 2.3.1.
NOTE: External overcurrent protection is not provided by this product, but is required by
codes. Refer to Table 4 and 5 for wiring requirements. If a lockable output disconnect is
required, it must be supplied by the user.
Table 7. UPS power cable terminal torques
UPS frame Function Tightening torque Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: battery +/-
3
PE (ground)
10 Nm for 16-35 mm
2
wire
6 Nm for 4-10 mm
2
wire
4 Nm for 2.5 mm
2
wire
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: battery +/-
6
PE (ground)
10 Nm for 16-35 mm
2
wire
6 Nm for 4-10 mm
2
wire
4 Nm for 2.5 mm
2
wire
EN
7
UPS frame Function Tightening torque Nm
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (ground)
10 Nm for 16-35 mm
2
wire
6 Nm for 4-10 mm
2
wire
4 Nm for 2.5 mm
2
wire
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (ground)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Action
Yes/No
All packing materials and restraints are removed from each cabinet.
Each cabinet in the UPS system is placed in its installed location.
A cabinet grounding kit / mounting kit is installed between any cabinets that are bolted
together.
All conduits and cables are properly routed to the UPS and any ancillary cabinets.
All power cables are properly sized and terminated.
Neutral conductors are installed and bonded to ground according to the requirements.
A ground conductor is properly installed.
Battery cables are terminated and connected to battery connectors.
Battery Shunt trip and Aux contact signal wiring is connected from the UPS to the battery
breaker.
LAN drops are installed.
All LAN connections are completed.
Air conditioning equipment is installed and operating correctly.
The area around the installed UPS system is clean and dust-free (it is recommended that
the UPS is installed on a level floor suitable for computer or electronic equipment).
There is adequate workspace around the UPS and other cabinets.
Adequate lighting is provided around all the UPS equipment.
A 230 VAC service outlet is located within 7.5 meters of the UPS equipment.
The Remote Emergency Power-off (REPO) device is mounted in its installed location
and its wiring is terminated inside the UPS cabinet.
If EPO is used in the NC configuration, a jumper is installed on the EPO between pins 1
and 2.
(OPTIONAL) Alarm relays and signal outputs are wired appropriately.
(OPTIONAL) A remote battery disconnect control is mounted in its installed location and
its wiring is terminated inside the UPS and battery cabinet.
(OPTIONAL) Accessories are mounted in their installed locations and their wiring is
terminated inside the UPS cabinet.
Start-up and operational checks are performed by an authorized Eaton Customer
Service Engineer or by a qualified service engineer authorized by Eaton.
EN
8
The unpacking and unloading of the UPS is shown in illustrations 9.1 - 9.8.
Before you start to unpack and unload the UPS, check the TipNTell and DropNTell
indicators on the package surface. If the equipment has been correctly transported in the
upright position, the indicators should be intact. If the TipNTell indicator arrow has turned
all blue or the arrow head(s) of the DropNTell indicator are black, contact the appropriate
parties to report inappropriate transportation.
For transportation purposes, the UPS cabinet is bolted onto a wooden pallet. Before you
unload the cabinet from the pallet, use a forklift or other material handling equipment to
move the cabinet to the installation area.
WARNING
The UPS cabinet is heavy. If the unpacking instructions are not closely obeyed, the
cabinet may tip over and cause serious injury.
Do not tilt the UPS cabinet more than 10 degrees from the vertical or the cabinet may tip
over.
NOTE: After you have removed the shipping brackets, move the unit immediately away
from the pallet.
After you have removed the shipping brackets and retracted the leveling feet, do not use
a forklift to move the unit while it is still on the pallet. Note that the UPS cabinet is heavy
and there are casters under the cabinet.
If you remove the cabinet from its original installation location and transfer it to a new
location on a pallet, lower the leveling feet so that the cabinet is not resting on the
casters and attach the shipping brackets to the cabinet and the pallet.
The operator has to supply the wiring to connect the UPS to the local power source. The
installation of the UPS must be made by a locally qualified electrician. The installation
inspection and the initial start-up of the UPS and installing an extra battery cabinet must be
carried out by an authorized Eaton Customer Service Engineer or by a qualified service
personnel authorized by Eaton.
The installation of the UPS is shown in illustrations 10.1-10.5.
The UPS power cable terminals are shown in illustrations 6.1 (91PS 15 kW frame), 6.2
(93PS 20 kW frame), 7.1 (91PS 30kW frame with a common battery), 7.2 (91PS 30kW
frame with a separate battery option), 8.1 (93PS 40kW frame with a common battery) and
8.2 (93PS 40kW frame with a separate battery option).
X1
Rectifier input
X4/-
External battery -
X2
Bypass input
TB20
External battery trip
X3
UPS output
TB21
External battery trip
X4/+
External battery +
PE
Protective earth
UPM2
(separate battery)
EN
9
The UPS communication terminals are shown in illustrations 5.1 and 5.2. The terminals are
as follows:
1. TB11, not used
2. TB10, not used
3. TB9, not used
4. TB8, external CAN
termination
5. TB7, external CAN
6. TB6, pull chain bus
7. USB1, USB host
(connection to
accessories)
8. USB2, USB device
(connection to computer)
9. MiniSlot 1
10. TB1, signal input 1-5
11. TB2, not used
12. TB3, not used
13. Serial COM port RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, relay output
If installing a customer-supplied battery system, install the battery system according to the
battery and battery system manufacturer’s instructions and all the applicable national
codes and regulations.
For the battery specification, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and
Installation Guide.
The 91PS/93PS 8-40 kW UPS units are always equipped with an internal battery breaker,
which affects only the UPS internal batteries (except for the C model, where the internal
battery breaker can be used for external batteries). The external battery breaker is a crucial
part of the external battery cabinet or rack and must be placed in it. With the external
battery breaker, signal cabling is important.
Both internal and external battery breakers can be tripped (switched off) by energizing its
shunt trip coil. The shunt trip coils of external battery breakers are energized (controlled)
through connectors TB20 and TB21 (TB21 available only in the 8-40 kW UPS with
separate battery configuration). The default voltage of the shunt trip coil is 24 Vdc.
Battery trip wiring is shown in illustration 11. The parts are as follows:
A
External battery breaker
3
Pin 3, AUX contact
1
Pin 1, shunt trip coil +
4
Pin 4, AUX contact return
2
Pin 2, shunt trip coil -
For instructions on how to install the external battery cabinet and battery power cabling,
refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide and the
instruction manual provided with the external battery cabinet. Earth the external battery
cabinet / customer-supplied battery system to the PE terminal 17.
EPO is connected to the UPS's top front panel, on connector EPO. The connections of the
EPO switch are shown in illustration 12.
For information on installing interface connections, refer to the Eaton 91PS/93PS UPS 8-
40 kW Users and Installation Guide.
EN
10
One general purpose relay contact is provided as a standard feature on the UPS. An alarm
contact is also provided. The output relay configurations are shown in illustration 13.
You can use a normally-closed or normally-open contact. If the state of the contact
changes from the state you specify as normal, a signal is issued. You can connect this
contact to equipment at your facility (such as a light or an alarm bell) to let you know when
an alarm is active on the UPS.
NOTE: Contacts should not be operated in excess of 30 VAC (RMS) and 30 VDC at 5 A
maximum.
For information on wiring parallel 91PS/93PS UPS systems, refer to the Eaton 91PS/93PS
UPS 8-40 kW Users and Installation Guide.
EN
11
DE
1
GEFAHR
Wichtige Sicherheitsanweisungen!
Bewahren Sie diese Hinweise sicher auf!
Dieses Dokument enthält wichtige Sicherheitsanweisungen und eine Kurzanleitung dazu,
wie die Lieferung der USV überprüft und installiert wird. Diese Kurzanleitung dient
ausschließlich der Verwendung als Installationscheckliste vor Ort.
Die Zielgruppe dieses Dokuments sind erfahrene Fachleute, welche die Installation der
USV planen und durchführen.
GEFAHR
Bevor Sie die Arbeiten an der USV aufnehmen, lesen Sie die Installationsanweisungen
aus dem Benutzer- und Installationshandbuch der Eaton 91PS/93PS USV 8-40 kW
vollständig durch.
Die vollständige Anleitung kann unter www.eaton.com/91psand93ps heruntergeladen
werden.
Arbeiten in der USV müssen von einem autorisierten Eaton-Kundendienstmitarbeiter
oder von Kundendienstpersonal ausgeführt werden, das von Eaton qualifiziert wurde. Die
USV enthält keine Teile, die vom Benutzer gewartet werden müssen.
Die USV arbeitet mit Stromnetz, Batterie oder Bypass. Sie enthält Komponenten, die hohe
Ströme und Spannungen führen. Ein ordnungsgemäß installiertes Gehäuse ist geerdet und
nach IP20 gegen Stromschlag und Fremdkörper ausgelegt. Die USV ist jedoch ein
leistungsstarkes Stromversorgungssystem und sollte nur von qualifiziertem Personal
installiert und gewartet werden.
GEFAHR
Diese USV führt tödliche Spannungen.
Batterien stellen eine Gefahr durch Elektroschocks oder Verbrennungen durch
Kurzschlussstrom dar. Halten Sie die Sicherheitsvorkehrungen ein.
Batterien können HOHE SPANNUNGEN und KORRODIERENDE, GIFTIGE und
EXPLOSIVE Substanzen enthalten. Aufgrund der Batteriestränge können die
Ausgangsstecker hohe Spannungen aufweisen, auch wenn die AC-Versorgung nicht an
der USV angeschlossen ist. Lesen Sie die Abschaltungsanleitungen im Benutzer- und
Installationshandbuch.
ACHTUNG
Die USV wird durch die systemeigene Energiequelle (Batterien) mit Strom versorgt. Die
Ausgangsanschlüsse können auch unter Spannung stehen, wenn die USV von der
Wechselstromquelle getrennt ist. Um das Risiko eines Brandes oder Stromschlags zu
minimieren, installieren Sie diese USV in einem temperatur- und feuchtigkeitsgeregelten
Innenraum, der frei von leitenden Verunreinigungen ist.
Stapeln Sie den Schrank des USV 91PS/93PS Modells C nicht mit anderen ähnlichen
Schränken. Stapel Sie nichts oben auf den 91PS/93PS USV-Schrank. Wenn der Schrank
des USV 91PS/93PS Modells C auf einem Regal installiert wird, verwenden Sie die
notwendigen Träger, um zu verhindern, dass die USV umkippt oder herunterfällt.
12
DE
ACHTUNG
Die Umgebungstemperatur darf 40 °C nicht überschreiten. Betreiben Sie die USV nicht in
der Nähe von Wasser oder hoher Feuchtigkeit (maximal 95 %). Das System ist nicht für
den Einsatz im Freien geeignet.
Bevor Sie mit Installations- oder Wartungsarbeiten beginnen, stellen Sie sicher, dass alle
Wechsel- und Gleichstromquellen getrennt wurden. Der Strom kann von verschiedenen
Quellen stammen. Achten Sie auch darauf, dass das System geerdet ist / PE-Durchgang
hat.
In einem Parallelsystem können die Ausgangsanschlüsse auch unter Spannung stehen,
wenn die USV abgeschaltet ist.
Stromschlaggefahr. Um Verletzungen zu verhindern, führen Sie unter keinen Umständen
Änderungen an der Batterieverkabelung oder den Anschlüssen durch.
WICHTIG: Vergewissern Sie sich vor der Installation, dass Sie alle Batteriestränge
getrennt haben.
VORSICHT
Nur qualifiziertes Servicepersonal, das Kenntnisse über Batterien und die erforderlichen
Sicherheitsvorkehrungen hat, darf Installations- oder Servicearbeiten an Batterien
durchführen. Benutzen Sie bei Montage- und Wartungsarbeiten an Batterien geeignetes
Werkzeug für Arbeiten an spannungsführenden Teilen. Halten Sie nicht autorisierte
Personen von den Batterien fern.
Bevor Sie Batterien einbauen oder austauschen, beachten Sie alle Warnungen,
Vorsichtsmaßnahmen und Hinweise über eine angemessene Handhabung. Trennen Sie
die Batterien nicht, wenn sich die USV im Batteriemodus befindet.
Stellen Sie sicher, dass Ihre Austauschbatterien die gleiche Nummer haben und vom
gleichen Typ sind, wie die ursprünglich in der USV installierte Batterie. Genauere
Anweisungen finden Sie auf der USV.
Bevor Sie Batterieanschlüsse verbinden oder trennen, trennen Sie die Ladequelle, indem
Sie den entsprechenden Batteriestromkreistrenner öffnen.
Prüfen Sie, ob die Batterie versehentlich geerdet wurde. Ist dies der Fall, beseitigen Sie
die Erdungsverbindung. Die Berührung von Teilen einer geerdeten Batterie kann zu
Stromschlag führen.
Entsorgen Sie Batterien gemäß den regionalen Entsorgungsbestimmungen.
Werfen Sie die Batterien auf keinen Fall in ein Feuer. Batterien können explodieren,
wenn Sie Flammen ausgesetzt werden.
Um die Brandgefahr zu verringern, verbinden Sie ausschließlich mit einem Stromkreis,
der mit Eingangssicherungen mit den maximalen Nennströmen gemäß den nationalen
und lokalen Installationsvorschriften ausgestattet ist.
Um einen angemessenen Kühlluftstrom sicherzustellen, um Personen vor gefährlichen
Spannungen innerhalb der Einheit zu schützen, halten Sie die USV-Tür geschlossen und
die Frontplatten angebracht.
Vermeiden Sie die Platzierung bzw. den Betrieb des USV-Systems in der Nähe von Gas
oder elektrischen Wärmequellen.
Halten Sie die Betriebsumgebung innerhalb der in diesem Dokument angegebenen
Parameter. Stellen Sie sicher, dass die Umgebung der USV ordentlich, sauber und frei
von übermäßiger Feuchtigkeit ist.
Befolgen Sie alle GEFAHR-, VORSICHT- UND ACHTUNG-Hinweise, die innen und
außen an der Anlage angebracht sind.
13
DE
2
Die unterbrechungsfreie Stromversorgung (USV) Eaton® 91PS/93PS ist ein echtes Online-
, Dauerleistungs-, transformatorloses, doppelwandiges, einphasiges (91PS) oder
dreiphasiges (93PS) System. Es versorgt kritische Verbraucher mit aufbereitetem und
unterbrechungsfreiem Wechselstrom und schützt sie vor Stromausfällen. Die
Ausgangsnennleistungen der Eaton 91PS/93PS basieren auf den auf 15 kW oder 20 kW
ausgelegten unterbrechungsfreien Leistungsmodulen (UPM).
91PS/93PS ist auch als C-Modell erhältlich, welches aus dem elektrischen Teil des
91PS/93PS USV 15/20 kW-Rahmens ohne Batterieabteil besteht.
Tabelle 1. USV-Schrankleistungen
USV-Rahmen Bild
(Abbildung 1)
Anzahl der UPM Leistungen
91PS 15 kW
A und B
1 8, 10, 15 kW
91PS 30 kW
C
1 oder 2 8, 10, 15, 20, 30 kW
93PS 20 kW
A und B
1 8, 10, 15 oder 20 kW
93PS 40 kW
C
1 oder 2
8, 10, 15, 20, 30 oder
40 kW
Die Hauptteile der 91PS/93PS USV 8-40 kW sind in Abbildung 2 dargestellt. Die Hauptteile
sind wie folgt:
1. Bedienfeld
2. Türriegel
3. Leistungsmodul (UPM)
4. Interne Batterie (nicht in Modellen C)
5. Kommunikationsbereich
6. Eingangsschalter
7. Batterietrenner
8. Wartungs-Bypass-Schalter (optional)
.
GEFAHR
Diese USV führt tödliche Spannungen.
Arbeiten in der USV müssen von einem autorisierten Eaton-Kundendienstmitarbeiter
oder von Kundendienstpersonal ausgeführt werden, das von Eaton qualifiziert wurde. Die
USV enthält keine Teile, die vom Benutzer gewartet werden müssen.
Für die vollständigen Sicherheitsanweisungen, siehe das Benutzer- und
Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW.
Die USV muss gemäß den Empfehlungen des Benutzer- und Installationshandbuchs für
die Eaton 91PS/93PS USV 8-40 kW installiert werden.
Halten Sie sich zur Installation der USV an die folgende grundsätzliche Reihenfolge der
Schritte:
14
DE
1. Erstellen Sie einen Installationsplan für das USV-System.
2. Bereiten Sie Ihren Standort für das USV-System vor.
3. Überprüfen und packen Sie den USV-Schrank aus.
4. Entladen und installieren Sie den USV-Schrank und verkabeln Sie das System.
5. Vervollständigen Sie die Installations-Checkliste.
6. Lassen Sie autorisiertes Servicepersonal die Vorab-Betriebskontrollen durchführen und
das System in Betrieb nehmen.
HINWEIS: Kontrollen bei der Inbetriebnahme oder während des Betriebs müssen von
einem autorisierten Eaton-Kundendienstmitarbeiter oder durch qualifiziertes von Eaton
autorisiertes Wartungspersonal durchgeführt werden, andernfalls werden die in der
Garantie angegebenen Garantiebedingungen ungültig.
Vor der Installation des USV-Systems lesen Sie diese Anweisungen und verstehen Sie,
wie sie auf das zu installierende System anzuwenden sind. Verwenden Sie die
angegebenen Abläufe und Abbildungen, um einen logischen Plan für die Installation des
Systems zu erstellen.
Damit das USV-System mit höchster Effizienz läuft, muss der Installationsstandort die
Umgebungsparameter erfüllen, die im Benutzer- und Installationshandbuch für die Eaton
91PS/93PS USV 8-40 kW aufgeführt sind.
Die Installationsumgebung muss den Gewichts- und Größenanforderungen der USV laut
Tabelle 2 und 3 entsprechen.
Die Abmessungen des USV-Schranks sind in Abbildung 1 dargestellt. Beachten Sie, dass
die Tiefenabmessungen (750 mm) Kabeleinführungen enthalten.
Tabelle 2. Gewichte des USV-Schranks mit Kartonverpackung
Modell C 8-20 kW
(Abbildung 1,
Bild A)
15/20 kW Rahmen*
(Abbildung 1,
Bild B)
30/40 kW Rahmen*
(Abbildung 1, Bild C)
Versandgewicht
98 kg
293 kg
558 kg
Montagegewicht
86 kg
280 kg
532 kg
Bodenbelastung
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Maximale Anzahl interner Batterien sind bei allen Modellen enthalten.
Die USV-Schränke verwenden Zwangsluftkühlung, um die Innentemperatur der
Komponenten zu regulieren. Standardmäßig befinden sich Lufteinlässe in der Vorderseite
des Schranks und Auslässe in der Rückseite; siehe Abbildung 3. Lassen Sie für eine
ordnungsgemäße Luftzirkulation einen Abstand vor und hinter jedem Schrank. Stellen Sie
sicher, dass die Kühlluft, die in die USV einströmt, nicht +40 °C überschreitet. Zu den
Kühlungsanforderungen, siehe das Benutzer- und Installationshandbuch für die Eaton
91PS/93PS USV 8-40 kW.
15
DE
Tabelle 3. Mindestabstände für USV-Schränke
15/20 kW Rahmen
(Abbildung 1,
Bilder A und B)
30/40 kW Rahmen
(Abbildung 1,
Bild C)
Von der Oberseite des
Schranks
500 mm* 500 mm*
Von der Vorderseite des
Schranks
500 mm* 650 mm*
Von der Rückseite des
Schranks
150 mm* 250 mm*
Von der Seite des Schranks
0 mm* 0 mm*
Die empfohlene Umgebungsbetriebstemperatur und Luftfeuchtigkeit für das USV-System
ist in Abbildung 4.1 und 4.2 dargestellt. Eine Umgebungstemperatur von +20 °C bis +25 °C
wird empfohlen, um eine lange Lebensdauer der VRLA-Batterien zu erzielen.
Tabelle 4. Mindestanforderungen an das Mehrleiterkabel und die Dimensionierung der Sicherungen
für den Gleichrichter und den Bypass-Eingang sowie für die USV-Ausgangskabel
(Dreiphasen-Eingang, Dreiphasen-Ausgang)
93PS USV-Leistung (kW) 8 10 15 20 30 40
Kabel [mm
2
]
4*2,5 4*4 4*10 4*10 4*16 4*25
Gleichrichtersicherung [A]
20 20 32 40 63 80
Bypass-Sicherung [A]
20 20 32 40 63 80
PE-Kabel [mm
2
]
1*6 1*6 1*10 1*10 1*16 1*16
Maximaler
Leiterquerschnitt
20 kW Rahmen und 20 kW C-Modell: massiver Draht 16 mm
2
,
Litzendraht mit Pressklemme: 10 mm
2
40kW Rahmen: massiver Draht 70 mm
2
, Litzendraht mit
Pressklemme: 50 mm
2
Tabelle 5. Mindestanforderungen an das Mehrleiterkabel und die Dimensionierung der Sicherungen
für den Gleichrichter und den Bypass-Eingang sowie für die USV-Ausgangskabel
(Dreiphasen-Eingang, Einphasen-Ausgang)
91PS USV-Leistung (kW) 8 10 15 20 30
Gleichrichterkabel [mm
2
]
2,5 4 10 10 16
Gleichrichtersicherung [A]
20 20 32 40 63
Bypass, Ausgangskabel
[mm
2
]
10 16 25 35 70
Bypass-Sicherung [A]
50 63 80 100 160
16
DE
91PS USV-Leistung (kW) 8 10 15 20 30
PE-Kabel [mm
2
]
10 16 16 16 35
Maximaler
Leiterquerschnitt, 15 kW
Rahmen und 15 kW C-
Modell
Gleichrichter: massiver Draht 16 mm
2
, Litzendraht mit
Pressklemme: 10 mm
2
Bypass/Ausgang: massiver Draht 70 mm
2
, Litzendraht
mit Pressklemme: 50 mm
2
Maximaler
Leiterquerschnitt, 30 kW
Rahmen
Gleichrichter: massiver Draht 70 mm
2
, Litzendraht mit
Pressklemme: 50 mm
2
Bypass/Ausgang: massiver Draht 95 mm
2
, Litzendraht
mit Pressklemme: 95 mm
2
VORSICHT
Stellen Sie sicher, dass der voraussichtliche Kurzschlussstrom, der an den
Eingangsanschlüssen der USV auftritt, gleich oder geringer ist als der bedingte
Kurzschlussstrom, der auf dem Leistungsschild der USV angegeben ist.
Tabelle 6. Empfohlene Mindestkabelstärken und Sicherungsstärken für externe Batteriebank
USV-Nennleistung (kW) 8 10 15 20 30 40
Plus- & Minus-Leitung
[mm
2
]
1*16 1*16 1*16 1*16 1*35 1*35
Batteriesicherung [A]
63 63 63 63 160 160
PE-Kabel [mm
2
]
1*16 1*16 1*16 1*16 1*16 1*16
Maximaler
Leiterquerschnitt
15/20 kW-Rahmen, C-Modell und 30/40 kW-Rahmen mit eigener
Batterie: massiver Draht: 25 mm
2
, Litzendraht mit Pressklemme: 16
mm
2
30/40 kW Rahmen mit üblicher Batterie: massiver Draht: 90 mm
2
,
Litzendraht mit Pressklemme: 70 mm
2
Für Informationen zu Nenn- und Maximalströmen, Nennleistung und Spannung, siehe das
Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW.
Für die Option mit externer separater Batterie sind separate Anschlüsse für beide
Batteriebänke (Schaltschränke) vorhanden, siehe Abschnitt 2.3.1.
HINWEIS: Externer Überstromschutz wird durch dieses Produkt nicht geboten, ist aber
vorschriftsmäßig erforderlich. Anforderungen für die Verkabelung siehe Tabelle 4 und 5.
Wenn ein abschließbarer Ausgangstrenner erforderlich ist, muss er vom Benutzer
bereitgestellt werden.
Tabelle 7. Anzugsmomente der USV-Hauptstromkabelanschlüsse
USV-Rahmen Funktion Anzugsmoment Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: Batterie +/-
3
17
DE
USV-Rahmen Funktion Anzugsmoment Nm
PE (Erde)
10 Nm für 16-35 mm
2
-Kabel
6 Nm für 4-10 mm
2
-Kabel
4 Nm für 2,5 mm
2
-Kabel
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: Batterie +/-
6
PE (Erde)
10 Nm für 16-35 mm
2
-Kabel
6 Nm für 4-10 mm
2
-Kabel
4 Nm für 2,5 mm
2
-Kabel
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (Erde)
10 Nm für 16-35 mm
2
-Kabel
6 Nm für 4-10 mm
2
-Kabel
4 Nm für 2,5 mm
2
-Kabel
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (Erde)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Aktion
Ja/Nein
Sämtliche Verpackungsmaterialien und -arretierungen wurden von jedem Schrank
entfernt.
Jeder Schrank im USV-System ist an seiner vorgesehenen Position platziert.
Zwischen Schränken, die miteinander verschraubt werden, ist ein Schrank-Erdungs-
/Montagesatz installiert.
Alle Leitungsrohre und Kabel sind ordnungsgemäß zur USV und allen Hilfsschränken
geführt.
Alle Stromkabel sind ordnungsgemäß dimensioniert und angeschlossen.
Die Neutralleiter sind gemäß den Anforderungen installiert und auf der Erde befestigt.
Ein Erdungsleiter ist ordnungsgemäß installiert.
Batteriekabel haben Abschlüsse und sind mit Batterieanschlüssen verbunden.
Batterie-Arbeitsstromauslöse- und Hilfskontaktsignalverkabelung sind von der USV mit
dem Batterietrenner verbunden.
LAN-Verbindungspunkte sind installiert.
Alle LAN-Verbindungen sind hergestellt.
Klimaanlage ist installiert und funktioniert richtig.
Der Bereich um das installierte USV-System herum ist sauber und staubfrei (es wird
empfohlen, die USV auf einem ebenen Boden zu installieren, der sich für Computer oder
elektronische Geräte eignet).
Um die USV und die anderen Schränke ist ausreichend Arbeitsplatz vorhanden.
Um alle USV-Anlagen ist ausreichend Beleuchtung vorhanden.
Eine 230 VAC Servicesteckdose befindet sich innerhalb von 7,5 Metern von der USV-
18
DE
Aktion Ja/Nein
Anlage entfernt.
Der Not-Aus-Fernschalter (REPO) ist an seiner vorgesehenen Position montiert und
seine Verkabelung innerhalb des USV-Schranks vollständig durchgeführt.
Falls der Not-Aus-Schalter in der Öffnerkonfiguration verwendet wird, ist auf dem Not-
Aus-Schalter zwischen den Pins 1 und 2 eine Brücke installiert.
(OPTIONAL) Alarmrelais und Signalausgänge sind ordnungsgemäß verkabelt.
(OPTIONAL) Eine Batterietrenn-Fernsteuerung ist an ihrer Installationsposition montiert
und ihre Verkabelung ist innerhalb des USV- und Batterieschranks angeschlossen.
(OPTIONAL) Das Zubehör ist in den Installationspositionen montiert und die
Verkabelung innerhalb des USV-Schranks durchgeführt.
Kontrollen bei der Inbetriebnahme oder während des Betriebs werden von einem
autorisierten Eaton-Kundendienstmitarbeiter oder von Kundendienstpersonal ausgeführt,
das von Eaton qualifiziert wurde.
Das Auspacken und Abladen der USV ist in den Abbildungen 9.1 - 9.8 dargestellt.
Bevor Sie beginnen, die USV auszupacken und abzuladen, schauen Sie auf die TipNTell /
DropNTell-Anzeige auf der Paketfläche. Falls das Gerät richtig in der aufrechten Position
transportiert wurde, müssen die Anzeigen intakt sein. Wenn der TipNTell-Anzeigepfeil
ganz blau ist oder die Pfeilspitze(n) der DropNTell-Anzeige schwarz sind, wenden Sie sich
an die entsprechenden Personen, um unangemessenen Transport zu melden.
Zu Transportzwecken ist der USV-Schrank auf einer Holzpalette festgeschraubt. Bevor Sie
den Schrank von der Palette abladen, verwenden Sie einen Gabelstapler oder ein
entsprechendes Flurfördermittel, um den Schrank zum Installationsort zu bewegen.
ACHTUNG
Der USV-Schrank ist schwer. Wenn die Auspackanweisungen nicht genau beachtet
werden, kann der Schrank kippen und ernsthafte Verletzungen verursachen.
Kippen Sie den USV-Schrank um nicht mehr als 10° aus der Vertikalen, ansonsten kann
der Schrank umkippen.
HINWEIS: Nachdem Sie die Transportstützen entfernt haben, bewegen Sie die Einheit
sofort von der Palette herunter.
Nachdem Sie die Transportstützen entfernt und die Nivellierfüße hineingedreht haben,
verwenden Sie keinen Gabelstapler, um die Einheit zu bewegen, während sie sich noch
auf der Palette befindet. Beachten Sie, dass der USV-Schrank schwer ist und unter dem
Schrank über Rollen verfügt.
Wenn der Schrank von seiner ursprünglichen Installationsposition entfernt und auf einer
Palette zu einem neuen Standort gebracht wird, müssen die Nivellierfüße abgesenkt
werden, sodass Schrank nicht mehr auf den Rollen ruht, und die Versandklammern
müssen am Schrank und der Palette angebracht werden.
19
DE
Der Betreiber muss die Verkabelung bereitstellen, mit der die USV an die lokale
Stromquelle angeschlossen wird. Die Installation der USV muss von einem ausgebildeten
Elektroinstallateur durchgeführt werden. Die Überprüfung der Installation und der erste
Startvorgang der USV sowie das Installieren eines zusätzlichen Batterieschranks dürfen
nur von einem autorisierten Eaton-Kundendienstmitarbeiter oder Kundendienstpersonal
ausgeführt werden, das von Eaton qualifiziert wurde.
Die Installation der USV ist in den Abbildungen 10.1-10.5 dargestellt.
Die USV-Stromkabelklemmen sind in den Abbildungen 6.1 (Rahmen 91PS 15 kW), 6.2
(Rahmen 93PS 20 kW), 7.1 (Rahmen 91PS 30 kW mit gemeinsamer Batterie), 7.2
(Rahmen 91PS 30 kW mit separater Batterieoption), 8.1 (Rahmen 93PS 40 kW mit
gemeinsamer Batterie) und 8.2 (Rahmen 93PS 40 kW mit separater Batterieoption)
dargestellt.
X1
Gleichrichtereingang
X4/-
Externe Batterie -
X2
Bypass-Eingang
TB20
Externe Batterieauslösung
X3
USV-Ausgang
TB21
Externe Batterieauslösung
X4/+
Externe Batterie +
PE
Schutzleiter
UPM2
(separate Batterie)
Die USV-Kommunikationsanschlüsse sind in Abbildungen 5.1 und 5.2 dargestellt. Die
Anschlüsse sind wie folgt:
1. TB11, nicht verwendet
2. TB10, nicht verwendet
3. TB9, nicht verwendet
4. TB8, externe CAN-
Terminierung
5. TB7, externer CAN
6. TB6, Pull Chain-Bus
7. USB1, USB Host
(Verbindung zu
Zubehörgeräten)
8. USB2, USB-Gerät
(Verbindung zum
Computer)
9. MiniSlot 1
10. TB1, Signaleingang 1-5
11. TB2, nicht verwendet
12. TB3, nicht verwendet
13. Serieller COM-Port RS-
232
14. MiniSlot 2
15. TB4, Not-Aus-Schalter
16. TB5, Relais-Ausgang
Falls Sie ein Kundeneigenes Batteriesystem installieren, gehen Sie bei der Installation
nach den Anweisungen und anwendbaren Richtlinien und Vorschriften des Herstellers der
Batterie und des Batteriesystems vor.
Für die Batterievorgaben, siehe das Benutzer- und Installationshandbuch für die Eaton
91PS/93PS USV 8-40 kW.
Die 91PS/93PS 8-40 kW USV-Einheiten sind immer mit einem internen
Batterieunterbrecher ausgestattet, welcher sich nur auf die internen Batterien der USV
auswirkt (außer beim Modell C, wo der interne Batterieunterbrecher für externe Batterien
verwendet werden kann). Der externe Batterietrenner ist ein äußerst wichtiges Teil des
externen Batterieschranks oder Racks und muss sich unbedingt darin befinden. Beim
externen Batterietrenner ist die Signalverkabelung wichtig.
Sowohl interner als auch externer Batterietrenner können ausgelöst (abgeschaltet)
werden, indem deren Arbeitsstrom-Auslösespule angesteuert wird. Die Arbeitsstrom-
Auslösespulen der externen Batterietrenner werden über die Stecker TB20 und TB21
angesteuert (TB21 steht nur bei der 8-40 kW USV mit separater Batteriekonfiguration zur
Verfügung). Die voreingestellte Spannung der Arbeitsstrom-Auslösespule beträgt 24 Vdc.
20
DE
Die Batterieauslöseverkabelung wird in Abbildung 11 dargestellt. Die Teile sind wie folgt:
A
Externer Batterietrenner
3
Pin 3, Hilfskontakt
1
Pin 1, Arbeitsstrom-
Auslösespule +
4
Pin 4, Hilfskontakt-Rückfluss
2
Pin 2, Arbeitsstrom-
Auslösespule -
Anweisungen zur Installation des externen Batterieschranks und zur Verkabelung der
Batterie sind dem Benutzer- und Installationshandbuch für die Eaton 91PS/93PS 8-40 kW
und dem Anleitungshandbuch des externen Batterieschranks zu entnehmen. Erden Sie
den externen Batterieschrank / das vom Kunden bereitgestellte Batteriesystem mit dem
PE-Anschluss 17.
Der Not-Aus-Schalter wird an der oberen Frontplatte der USV, am Not-Aus-Schalter-
Verbinder, angeschlossen. Die Anschlüsse des Not-Aus-Schalters sind in Abbildung 12
dargestellt.
Für Informationen zur Installation der Schnittstellenverbindungen, siehe das Benutzer- und
Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW.
Ein Universal-Relaiskontakt wird als Standardfunktion der USV geliefert. Ein Alarmkontakt
steht ebenfalls zur Verfügung. Die Ausgaberelaiskonfigurationen sind in Abbildung 13
dargestellt.
Sie können einen Öffner- oder Schließerkontakt verwenden. Wenn der Status von dem als
normal angegebenen Status abweicht, ertönt ein Signal. Sie können diesen Kontakt mit
der Anlage in Ihrer Einrichtung (wie z. B. einem Licht oder einer Alarmglocke) verbinden,
damit Sie wissen, wann ein Alarm in der USV aktiv ist.
HINWEIS: Kontakte sollten nicht bei mehr als 30 VAC (RMS) und 30 VDC bei maximal 5 A
betrieben werden.
Für Informationen zur Verkabelung paralleler 91PS/93PS-USV-Systeme, siehe das
Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW.
21
FR
1
DANGER
Instructions importantes pour la sécurité !
Conservez ces instructions !
Ce document fournit des instructions importantes relatives à la sécurité et des instructions
succinctes pour le contrôle de la livraison et le mode d'installation de l'UPS. Ce guide
rapide est uniquement destiné à servir de liste de contrôle de l'installation sur site.
Ce document est destiné à un public de professionnels expérimentés qui planifient et
exécutent l'installation de l'UPS.
DANGER
Avant de travailler sur l'UPS, lisez l'intégralité des instructions d'installation fournies dans
le Guide d'utilisation et d'installation des UPS Eaton 91PS/93PS 8-40 kW.
Les instructions complètes sont disponibles en téléchargement sur
www.eaton.com/91psand93ps.
Les opérations à l'intérieur de l'UPS doivent être réalisées par un ingénieur agréé du
service client d'Eaton ou par le personnel d'entretien qualifié agréé par Eaton. Aucune
partie de l'UPS ne peut être entretenue par l'utilisateur.
L'UPS fonctionne à l'aide d'une alimentation secteur, par batteries ou de dérivation. Il
contient des composants qui véhiculent des courants et tensions élevés. Pour être
correctement installé, son châssis doit être mis à la masse et protégé conformément à la
norme IP20 contre les chocs électriques et la pénétration de corps étrangers. Toutefois,
l'UPS est un système d'alimentation sophistiqué qui ne peut être installé et entretenu que
par du personnel qualifié.
DANGER
Cet UPS renferme des tensions mortelles.
Les batteries présentent un risque de choc électrique ou de brûlure dû à un courant de
court-circuit élevé. Respectez les précautions.
Les batteries peuvent contenir des TENSIONS ÉLEVÉES, ainsi que des substances
CORROSIVES, TOXIQUES et EXPLOSIVES. Les batteries étant en chaîne, les prises
de sortie peuvent présenter une tension élevée même si l'alimentation CA n'est pas
connectée à l'UPS. Lisez les instructions d'arrêt du Guide d'utilisation et d'installation.
AVERTISSEMENT
L'UPS est alimenté par sa propre source d'énergie (batteries). Les bornes de sortie
peuvent être actives, même si l'UPS est déconnecté d'une source d'alimentation CA.
Pour réduire le risque d'incendie ou de choc électrique, installez cet UPS dans un
environnement intérieur où la température et l'humidité sont contrôlées et exempt de
contaminants conducteurs.
N'empilez pas l'armoire d'UPS 91PS/93PS modèle C sur d'autres armoires similaires.
N'empilez rien au sommet de l'armoire d'UPS 91PS/93PS. Si l'armoire d'UPS 91PS/93PS
modèle C est installée sur une étagère, utilisez les supports nécessaires pour éviter que
l'UPS ne bascule ou ne chute.
22
FR
AVERTISSEMENT
La température ambiante ne doit pas dépasser 40 °C. N'utilisez pas l'UPS à proximité
d'eau ou dans une humidité excessive (95 % maximum). Le système n'est pas prévu
pour un usage en extérieur.
Avant tout travail d'installation ou d'entretien, assurez-vous que toutes les sources
d'alimentation CA et CC sont déconnectées. L'alimentation peut provenir de plusieurs
sources. Assurez-vous aussi de la mise à la terre et de la continuité PE du système.
Dans un système parallèle, les bornes de sortie peuvent être sous tension même si l'UPS
est arrêté.
Risque électrique. Pour éviter les blessures, ne tentez pas de modifier un quelconque
câblage ou connecteur des batteries.
IMPORTANT : Assurez-vous de déconnecter tous les chaînes de batteries avant
l'installation.
ATTENTION
Seul un personnel d'entretien qualifié, familier des batteries et des précautions requises,
est autorisé à assurer les travaux d'installation ou d'entretien sur les batteries. Les
travaux d'installation et d'entretien sur les batteries s'effectuent sous tension et
nécessitent l'usage d'outils de tension. Maintenez le personnel dépourvu d'autorisation à
distance des batteries.
Avant d'installer ou de remplacer des batteries, tenez compte de tous les avertissements,
précautions et notes concernant la manutention correcte. Ne déconnectez pas les
batteries si l'UPS est en mode batterie.
Assurez-vous de remplacer les batteries par un nombre et un type de batteries
respectant l'installation d'origine dans l'UPS. L'UPS fournit des instructions plus précises.
Avant de connecter ou déconnecter les bornes de batterie, déconnectez la source de
chargement en ouvrant le disjoncteur de batterie correspondant.
Vérifiez que la batterie n'est pas reliée à la terre par inadvertance. Si c'est le cas,
supprimez cette mise à la terre. Tout contact avec un élément d'une batterie mise à la
terre risque de provoquer un choc électrique.
Mettez les batteries au rebut selon vos impératifs de mise au rebut locaux.
Ne jetez pas les batteries dans un feu. Exposées à des flammes, les batteries peuvent
exploser.
Afin de réduire le risque d'incendie, connectez uniquement à un circuit respectant les
valeurs nominales maximales pour le courant d'entrée du disjoncteur, conformément aux
règles d'installation nationales et locales.
Afin d'assurer un flux d'air de refroidissement approprié et de protéger le personnel des
tensions dangereuses dans l'unité, maintenez la porte de l'UPS fermée et les panneaux
avant en place.
N'installez ou n'utilisez pas le système UPS à proximité de sources de chaleur électrique
ou à gaz.
Maintenez l'environnement de fonctionnement dans les paramètres mentionnés dans ce
document. Maintenez les alentours de l'UPS dégagés, propres et exempts d'humidité
excessive.
Observez toutes les notifications DANGER, ATTENTION et AVERTISSEMENT
apposées à l'intérieur et à l'extérieur de l'équipement.
23
FR
2
Les systèmes d'alimentation sans interruptions (UPS) Eaton® 91PS/93PS 8-10 kW sont
de véritables systèmes en ligne, à fonctionnement continu, sans transformateur, double-
conversion, à semi-conducteurs, monophasés (91PS) ou triphasés (93PS). Ils fournissent
une alimentation CA conditionnée et sans coupure vers la charge critique pour la protéger
contre les coupures d'électricité. Les valeurs nominales de puissance de sortie de l'Eaton
91PS/93PS sont basées sur des modules d'alimentation sans coupure (UPM) avec une
valeur nominale de 15 ou 20 kW.
Le modèle 91PS/93PS est aussi disponible dans sa version C qui comprend la partie
électrique du châssis de l'UPS 91PS/93PS 15/20 kW mais sans le compartiment de
batteries.
Tableau 1. Valeurs nominales de l'armoire de l'UPS
Châssis d'UPS
Image
(Illustration 1)
Nombre d'UPM
Valeurs nominales
91PS 15 kW
A et B
1
8, 10 ou 15 kW
91PS 30 kW
C
1 ou 2
8, 10, 15, 20 ou 30 kW
93PS 20 kW
A et B
1
8, 10, 15 ou 20 kW
93PS 40 kW
C
1 ou 2
8, 10, 15, 20, 30 ou 40
kW
Les pièces principales de l'UPS 91PS/93PS 8-40 kW sont indiquées dans l'illustration 2.
Les pièces principales sont les suivantes :
1. Panneau de commande
2. Verrou de porte
3. Module d'alimentation (UPM)
4. Batterie interne (sauf modèles C)
5. Zone de communications
6. Commutateur d'entrée
7. Disjoncteur de batterie
8. Commutateur de dérivation de
maintenance (en option)
.
DANGER
Cet UPS renferme des tensions mortelles.
Les opérations à l'intérieur de l'UPS doivent être réalisées par un ingénieur agréé du
service client d'Eaton ou par le personnel d'entretien qualifié agréé par Eaton. Aucune
partie de l'UPS ne peut être entretenue par l'utilisateur.
Pour des instructions complètes relatives à la sécurité, consultez le Guide d'utilisation et
d'installation de l'UPS Eaton 91PS/93PS 8-40 kW.
L'UPS doit être installé selon les recommandations du Guide d'utilisation et d'installation
de l'UPSD Eaton 91PS/93PS 8-40 kW.
Procédez comme suit et dans l'ordre pour installer l'UPS :
24
FR
1. Créez un plan d'installation pour le système UPS.
2. Préparez le site pour le système UPS.
3. Inspectez et déballez l'armoire de l'UPS.
4. Déchargez et installez l'armoire de l'UPS, puis câblez le système.
5. Remplissez la liste de contrôle de l'installation.
6. Organisez la venue d'un personnel qualifié pour la mise en service et la vérification du
bon fonctionnement.
NOTE : La mise en service et la vérification du bon fonctionnement devront être exécutées
par un ingénieur du service clientèle d'Eaton ou par le personnel d'entretien qualifié agréé
par Eaton ; autrement, les conditions générales de la garantie énoncées dans la Garantie
sont annulées.
Avant d'installer le système UPS, il est indispensable de lire et de comprendre comment ce
manuel s'applique au système à installer. Utilisez les procédures et illustrations fournies
pour créer un plan logique d'installation du système.
Afin que le système UPS puisse fonctionner avec une efficience optimale, le site
d'installation doit être conforme aux conditions environnementales exposées dans le Guide
d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW.
Le cadre d'installation doit être conforme aux exigences de poids et d'encombrement de
l'UPS énoncées aux Tableaux 2 et 3.
Les dimensions de l'armoire d'UPS sont indiquées dans l'illustration 1. Notez que la
dimension de profondeur (750 mm) inclut les presse-étoupe.
Tableau 2. Poids des armoires UPS avec emballage carton
Modèle C 8-20 kW
(Illustration 1,
image A)
Châssis 15/20 kW*
(Illustration 1,
image B)
Châssis 30/40 kW*
(Illustration 1,
image C)
Poids pour l'expédition
98 kg
293 kg
558 kg
Poids installé
86 kg
280 kg
532 kg
Charge au sol
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Des batteries internes maximum sont incluses avec tous les modèles.
Les armoires UPS utilisent un apport d'air froid pulsé pour réguler la température des
composants internes. Par défaut, les entrées d'air sont situées à l'avant de l'armoire et les
sorties sont situées à l'arrière - voir illustration 3. Prévoyez un dégagement suffisant
devant et derrière chaque armoire pour une circulation d'air correcte. La température de
l'air froid qui pénètre dans l'UPS ne doit pas dépasser +40 °C Pour les besoins de
ventilation, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40
kW.
25
FR
Tableau 3. Dégagements minimum autour de l'armoire de l'UPS
Châssis 15/20 kW
(Illustration 1,
images A et B)
Châssis 30/40 kW
(Illustration 1,
image C)
Depuis le haut de l'armoire
500 mm
500 mm
Depuis l'avant de l'armoire
500 mm
650 mm
Depuis l'arrière de l'armoire
150 mm
250 mm
Depuis le côté de l'armoire
0 mm
0 mm
Les température et humidité ambiantes de service recommandées pour le système UPS
sont indiquées dans les illustrations 4.1 et 4.2. Une température ambiante entre +20 °C et
+25 °C est recommandée pour assurer un cycle de vie prolongé des batteries VRLA.
Tableau 4. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour les câbles
d'entrée de redresseur et dérivation et de sortie d'UPS (entrée triphasée - sortie triphasée)
Nominal d'UPS 93PS (kW)
8
10
15
20
30
40
Câble [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Fusible de redresseur [A]
20
20
32
40
63
80
Fusible de dérivation [A]
20
20
32
40
63
80
Câble PE [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Section maximum de
conducteur
Châssis 20 kW et modèle C 20 kW : fil plein de 16 mm
2
, fil torsadé
avec férule : 10 mm
2
Châssis 40kW : fil plein de 70 mm
2
, fil torsadé avec férule : 50 mm
2
Tableau 5. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour les câbles
d'entrée de redresseur et dérivation et de sortie d'UPS (entrée triphasée - sortie
monophasée)
Nominal d'UPS 91PS (kW)
8
10
15
20
30
Câble de redresseur [mm
2
]
2,5
4
10
10
16
Fusible de redresseur [A]
20
20
32
40
63
Dérivation, câble de sortie
[mm
2
]
10
16
25
35
70
Fusible de dérivation [A]
50
63
80
100
160
Câble PE [mm
2
]
10
16
16
16
35
Section maximum de
conducteur, châssis 15 kW
et modèle C 15 kW
Redresseur : fil plein de 16 mm
2
, fil torsadé avec férule :
10 mm
2
Dérivation /sortie : fil plein de 70 mm
2
, fil torsadé avec
férule : 50 mm
2
26
FR
Nominal d'UPS 91PS (kW)
8
10
15
20
30
Section maximum de
conducteur, châssis 30 kW
Redresseur : fil plein de 70 mm
2
, fil torsadé avec férule :
50 mm
2
Dérivation /sortie : fil plein de 95 mm
2
, fil torsadé avec
férule : 95 mm
2
ATTENTION
Assurez-vous que le courant de court-circuit prévu résultant sur les bornes d'entrée de
l'UPS est égal ou inférieur à celui du courant de court-circuit conditionnel de la plaque de
type de l'UPS.
Tableau 6. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour le banc de
batteries externe
Nominal d'UPS (kW)
8
10
15
20
30
40
Ligne pos. & nég. [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Fusible de batterie [A]
63
63
63
63
160
160
Câble PE [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Section maximum de
conducteur
Châssis 15/20 kW, modèle C et châssis 30/40 kW avec batterie
séparée : fil plein : 25 mm
2
, fil torsadé avec férule : 16 mm
2
Châssis 30/40 kW avec batterie standard : fil plein : 90 mm
2
, fil
torsadé avec férule : 70 mm
2
Pour en savoir plus sur les courants nominaux et maximum pour les puissances et tension
nominales, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40
kW.
Pour l'option batterie séparée externe, des terminaux distincts sont prévus pour les deux
bancs de batteries (armoires) - voir la section 2.3.1.
NOTE : La protection externe contre les surintensités n'est pas fournie par ce produit mais
elle est exigée par la réglementation. Pour les exigences de câblage, se reporter à
tableaux 4 et 5. Si un dispositif de déconnexion verrouillable de sortie est requis, il doit être
fourni par l'utilisateur.
Tableau 7. Couples de bornes de câble d'alimentation d'UPS
Châssis d'UPS
Fonction
Couple de serrage (Nm)
93PS 20 kW
X1, X2, X3 : L1, L2, L3, N
1.6
X4 : batterie +/-
3
PE (terre)
10 Nm pour fil de 16-35 mm
2
6 Nm pour fil de 4-10 mm
2
4 Nm pour fil de 2,5 mm
2
93PS 40 kW
X1, X2, X3 : L1, L2, L3, N
6
X4 : batterie +/-
6
27
FR
Châssis d'UPS
Fonction
Couple de serrage (Nm)
PE (terre)
10 Nm pour fil de 16-35 mm
2
6 Nm pour fil de 4-10 mm
2
4 Nm pour fil de 2,5 mm
2
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (terre)
10 Nm pour fil de 16-35 mm
2
6 Nm pour fil de 4-10 mm
2
4 Nm pour fil de 2,5 mm
2
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (terre)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Action
Oui/Non
Tous les matériaux d'emballage et accessoires de fixation sont retirés de chaque
armoire.
Chaque armoire du système UPS est placée sur son site d'installation.
Un kit de mise à la terre/montage de l'armoire est installé entre les armoires boulonnées
ensemble.
Tous les câbles et gaines sont correctement acheminés vers l'UPS et les armoires
auxiliaires.
Tous les câbles d'alimentation sont aux bonnes dimensions et raccordés correctement.
Les conducteurs neutres sont raccordés ou liés à la masse conformément aux
exigences.
Un conducteur de terre est correctement installé.
Les câbles de batterie sont raccordés aux connecteurs de batterie.
Un shunt de dérivation et un câblage de signal de contact auxiliaire sont connectés de
l'UPS vers le disjoncteur de batterie.
Des branchements LAN sont installés.
Toutes les connexions LAN sont exécutées.
La climatisation est installée et fonctionne correctement.
La zone autour du système UPS installé est propre et dépoussiérée (Il est recommandé
d'installer le système UPS sur un sol adapté à l'équipement informatique ou
électronique).
Un dégagement adéquat est prévu autour de l'UPS et des autres armoires.
Un éclairage correct est prévu autour de tout l'équipement de l'UPS.
Il existe une prise de courant de service de 230 V CA à 7,5 mètres au plus du site
d'installation de l'UPS.
Le dispositif d'arrêt d'urgence à distance (REPO) est correctement installé et son
câblage est raccordé à l'intérieur de l'armoire de l'UPS.
Si l'EPO est utilisé dans la configuration NF, un cavalier est installé sur l'EPO entre les
broches 1 et 2.
28
FR
Action
Oui/Non
(OPTION) Les relais d'alarme et sorties de signal sont correctement câblés.
(OPTION) Une commande de déconnexion de batterie à distance est montée sur son
site d'installation et son câblage est raccordé à l'intérieur de l'armoire de l'UPS et à
l'armoire de la batterie.
(OPTION) Les accessoires sont montés sur leur site d'installation et leurs câblages sont
raccordés à l'intérieur de l'armoire de l'UPS.
La mise en service et la vérification du bon fonctionnement sont réalisées par un
ingénieur agréé du service client d'Eaton ou par l'ingénieur d'entretien qualifié agréé par
Eaton.
Le déballage et le déchargement de l'UPS sont indiqués dans les illustrations 9.1 - 9.8.
Avant de commencer à déballer et décharger l'UPS, vérifiez l'indicateur TipNTell /
DropNTell sur la surface de l'emballage. Si l'équipement a été correctement transporté en
position verticale, les indicateurs devraient être intacts. Si la flèche de l'indicateur TipNTell
est devenue toute bleue ou si la ou les flèches de l'indicateur DropNTell sont noires,
contactez les parties concernées pour déclarer un transport incorrect.
Pour son transport, l'armoire de l'UPS est boulonnée sur la palette en bois. Avant de la
décharger de la palette, utilisez un chariot élévateur ou tout autre équipement de
manutention pour déplacer l'armoire vers le site d'installation.
AVERTISSEMENT
L'armoire de l'UPS est lourde. Si les instructions de déballage ne sont pas suivies à la
lettre, l'armoire risque de basculer et de provoquer des blessures graves.
N'inclinez pas l'armoire de l'UPS à un angle supérieur à 10 degrés depuis la verticale :
elle pourrait basculer.
NOTE : Une fois les supports d'expédition retirés, écartez immédiatement l'unité de la
palette.
Une fois les supports d'expédition retirés et les pieds de réglage rentrés, n'utilisez pas de
chariot élévateur pour déplacer l'unité tant qu'elle se trouve sur la palette. Notez que
l'armoire de l'UPS est lourde et que des roulettes sont situées dessous.
Si l'armoire est déplacée de son emplacement d'installation d'origine vers un nouvel
emplacement sur une palette, les pieds de réglage doivent être abaissés jusqu'à ce que
l'armoire ne repose plus sur les roulettes et les supports d'expédition doivent être fixés
sur l'armoire et la palette.
L'opérateur doit fournir le câblage pour la connexion de l'UPS à la source d'alimentation
locale. L'installation de l'UPS doit être confiée à un électricien local qualifié. L'inspection de
l'installation et la mise en service initiale de l'UPS ainsi que l'installation d'une armoire de
batteries supplémentaire doivent être effectuées par un ingénieur agréé du service client
d'Eaton ou par un personnel d'entretien qualifié agréé par Eaton.
29
FR
L'installation de l'UPS est indiquée dans les illustrations 10.1-10.5.
Les bornes de câble d'alimentation de l'UPS sont illustrées en 6.1 (91PS châssis 15 kW),
6.2 (93PS châssis 20 kW), 7.1 (91PS châssis 30kW avec batterie commune), 7.2 (91PS
châssis 30kW avec option de batterie séparée), 8.1 (93PS châssis 40kW avec batterie
commune) et 8.2 (93PS châssis 40kW avec option de batterie séparée).
X1
Entrée de redresseur
X4/-
Batterie externe -
X2
Entrée de dérivation
TB20
Excitation de batterie externe
X3
Sortie de l'UPS
TB21
Excitation de batterie externe
X4/+
Batterie externe +
PE
Terre de protection
UPM2
(batterie séparée)
Les bornes de communication de l'UPS sont illustrées en 5.1 et 5.2. Les bornes sont les
suivantes :
1. TB11, sans usage
2. TB10, sans usage
3. TB9, sans usage
4. TB8, raccordement
CAN externe
5. TB7, CAN externe
6. TB6, bus de chaînage
7. USB1, hôte USB
(connexion aux
accessoires)
8. USB2, dispositif USB
(connexion à l'ordinateur)
9. Mini-Slot 1
10. TB1, entrée de signal 1-5
11. TB2, sans usage
12. TB3, sans usage
13. Port COM série RS-232
14. Mini-Slot 2
15. TB4, EPO
16. TB5, sortie de relais
2.3.2 Installation du système de batteries
S'il s'agit de l'installation d'un système de batteries fourni par le client, installez le système
de batterie conformément aux instructions du fabricant de batterie et du système de
batteries et conformément à tous les codes et réglementations nationaux applicables.
Pour les spécifications de batterie, consultez le Guide d'utilisation et d'installation de l'UPS
Eaton 91PS/93PS 8-40 kW.
Les unités UPS 91PS/93PS 8-40 kW sont toujours équipées d'un disjoncteur de batteries
internes qui affecte uniquement les batteries internes de l'UPS (sauf pour le modèle C dont
le disjoncteur de batteries internes peut servir pour les batteries externes). Le disjoncteur
des batteries externes est un élément crucial de l'armoire ou de la baie de batteries
externes et doit y être placé. Le câblage de signalisation est important avec le disjoncteur
de batterie externe.
Les disjoncteurs de batteries externes et internes peuvent être déclenchés (mis hors
tension) tous deux en mettant sous tension leur bobine d'excitation de shunt. Les bobines
d'excitation de shunt des disjoncteurs de batteries externes sont excitées (commandées)
via les connecteurs TB20 et TB21 (TB21 uniquement disponible pour UPS 8-40 kW avec
configuration de batterie séparée). La tension par défaut de la bobine d'excitation de shunt
est de 24 V CC.
Le câblage de la chaîne de batteries est indiqué en illustration 11. Les pièces sont les
suivantes :
A
Disjoncteur de batteries externes
3
Broche 3, contact AUX
1
Broche 1, bobine d'excitation de
shunt +
4
Broche 4, retour de contact AUX
2
Broche 2, bobine d'excitation de
shunt -
30
FR
Pour les instructions d'installation de l'armoire de batteries externes et le câblage
d'alimentation de batterie, consultez le Guide d'utilisation et d'installation des UPS Eaton
91PS/93PS 8-40 kW et le manuel d'instructions accompagnant l'armoire de batteries
externes. Mettez à la terre l'armoire de batteries externes /système de batteries fourni par
le client à la borne PE 17 illustrée.
L'EPO doit être raccordé au connecteur d'EPO du panneau avant supérieur de l'UPS. Les
connexions du commutateur EPO sont indiquées dans l'illustration 12.
Pour en savoir plus sur l'installation des connexions d'interface, consultez le Guide
d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW.
Un contact de relais à usage général est installé comme fonctionnalité standard sur l'UPS.
Un contact d'alarme est également fourni. Les configurations de relais de sortie sont
indiquées en illustration 13.
Utiliser un contact normalement fermé ou normalement ouvert. Si l'état du contact change
par rapport à l'état spécifié comme normal, un signal est émis. Ce contact peut être
connecté à l'équipement du bâtiment (par exemple, un éclairage ou une sonnette d'alarme)
afin d'avertir quand une alarme est active sur l'UPS.
NOTE : Les contacts ne doivent pas fonctionner au-delà de 30 V CA (RMS) et 30 V CC, à
un maximum de 5 A.
Pour en savoir plus sur le câblage en parallèle des systèmes d'UPS 91PS/93PS, consultez
le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW.
31
FI
1
VAARA
Tärkeitä turvallisuusohjeita!
Pidä nämä ohjeet tallessa!
Tässä asiakirjassa on tärkeitä turvallisuusohjeita ja lyhyet ohjeet UPS:n toimituksen
tarkistuksesta ja UPS:n asennuksesta. Tämä pikaopas on tarkoitettu käytettäväksi vain
asennuksen tarkistuslistana asennuspaikalla.
Tämä asiakirja on tarkoitettu UPS:n asennuksen suunnitteleville ja suorittaville kokeneille
ammattilaisille.
VAARA
Ennen töiden aloittamista UPS:llä lue täydelliset asennusohjeet, jotka on annettu Eaton
91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaassa.
Täydet ohjeet ovat ladattavissa osoitteesta: www.eaton.com/91psand93ps.
Työt UPS:n sisäpuolella saa suorittaa vain valtuutettu Eatonin asiakaspalveluinsinööri tai
Eatonin valtuuttama pätevä huoltohenkilöstö. UPS:n sisällä ei ole käyttäjän huollettavissa
olevia osia.
UPS toimii verkkovirran, akkuvirran tai ohitustehon varassa. Se sisältää komponentteja,
joissa kulkee suuria virtoja ja korkea jännite. Oikein asennettu kotelo on maadoitettu, ja
sillä on IP20-suojausluokitus sähköiskuja ja vierasesineitä vastaan. UPS on kuitenkin
kehittynyt virransyöttöjärjestelmä, ja vain pätevä henkilöstö saa tehdä asennus- ja
huoltotöitä UPS:lle.
VAARA
UPS:ssä on hengenvaarallisia jännitteitä.
Akut voivat muodostaa suuren oikosulkuvirran vuoksi sähköiskun tai palovammojen
riskin. Noudata varotoimia.
Akut saattavat sisältää KORKEITA JÄNNITTEITÄ sekä SYÖVYTTÄVIÄ, MYRKYLLISIÄ
ja PALAVIA aineita. Akkusarjasta johtuen lähtöliittimissä saattaa olla korkea jännite,
vaikka vaihtovirtalähdettä ei ole liitetty UPS:ään. Lue sammutusohjeet käyttö- ja
asennusoppaasta.
VAROITUS
UPS saa virtaa omista energianlähteistään (akustot). Lähtöliittimet saattavat olla
jännitteisiä silloinkin, kun UPS on kytketty irti vaihtovirtalähteestä. Tulipalo- tai
sähköiskuriskin vähentämiseksi tämä UPS on asennettava sisätilaan, paikkaan, jossa
lämpötilaa ja kosteutta valvotaan ja jossa ei ole sähköä johtavia epäpuhtauksia.
Älä pinoa UPS 91PS/93PS C -mallin kaappia muiden vastaavien kaappien päälle. Älä
pinoa mitään 91PS/93PS UPS -kaapin päälle. Jos UPS 91/93PS C -mallin kaappi
asennetaan hyllylle, käytä tarpeellisia tukia estämään UPS:n kaatuminen tai putoaminen.
32
FI
VAROITUS
Ympäristön lämpötila ei saa ylittää arvoa 40 °C. Älä käytä UPS-laitetta veden
läheisyydessä tai hyvin kosteassa ympäristössä (enintään 95 %). Järjestelmää ei ole
tarkoitettu ulkokäyttöön.
Varmista ennen asennus- tai huoltotyön aloittamista, että kaikki vaihto- ja
tasasähkölähteet on irrotettu. Virtaa voi tulla useista lähteistä. Varmista myös
järjestelmän maadoitus / PE-eheys.
Rinnakkaisjärjestelmässä lähtöliittimet saattavat olla jännitteisiä silloinkin, kun UPS on
sammutettu.
Sähkövaara. Estä loukkaantuminen. Älä yritä vaihtaa akkujen kytkentöjä tai liittimiä.
TÄRKEÄÄ: Varmista ennen asennusta, että irrotat kaikki akkusarjat.
HUOMAUTUS
Akkujen asennus- ja huoltotöitä saa suorittaa vain akut ja vaadittavat varotoimet tunteva
pätevä huoltohenkilöstö. Akkujen asennus ja huolto on jännitetyö ja edellyttää
jännitetyökalujen käyttöä. Älä päästä valtuuttamatonta henkilöstöä käsittelemään akkuja.
Harkitse ennen akkujen asennusta tai vaihtoa kaikkia akkujen asianmukaiseen
käsittelyyn liittyviä varoituksia, huomautuksia ja ilmoituksia. Älä kytke akkuja irti silloin,
kun UPS toimii akkutilassa.
Varmista uusien akkujen olevan määrältään ja tyypiltään samat kuin alkuperäiset UPS-
akut. Katso tarkemmat ohjeet UPS:stä.
Irrota ennen akkuliittimien kytkemistä tai irrotusta latauslähde avaamalla vastaava
akkuvirtapiirin katkaisija.
Määritä, onko akku maadoitettu tahattomasti. Jos näin on, irrota maalähde. Maadoitetun
akun mihinkään osaan koskeminen voi aiheuttaa sähköiskun vaaran.
Hävitä akut paikallisten hävitysvaatimusten mukaisesti.
Älä hävitä akkuja polttamalla. Akut saattavat räjähtää avotulelle altistuneena.
Tulipalovaaran pienentämiseksi laitteet saa liittää vain virtapiiriin, jonka
syöttövirtapiirikatkaisijan nimellisvirta on kansallisten ja paikallisten asennusmääräysten
mukainen.
Varmista asianmukainen jäähdytysilmavirtaus ja henkilöstön suojaus vaarallisilta
jännitteiltä UPS:n sisällä pitämällä laitteen ovi suljettuna ja etupaneelit asennettuna.
Älä asenna UPS-järjestelmää kaasulla tai sähköllä tuotettujen lämmönlähteiden lähelle
tai käytä sitä niiden lähellä.
Pidä toimintaympäristö tässä asiakirjassa määritettyjen parametrien puitteissa. Pidä
UPS:n ympäristö siistinä ja puhtaana, äläkä päästä ylimääräistä kosteutta kertymään.
Huomioi kaikki VAARA-, HUOMAUTUS- ja VAROITUS-merkinnät, jotka on kiinnitetty
laitteen si- tai ulkopuolelle.
33
FI
2
Eaton® 91PS/93PS keskeytymätön sähkönsyöttö (uninterruptible power supply – UPS) on
todellinen jatkuvasti toimiva, muuntajaton, kaksoismuuntava, puolijohtein toteutettu yksi-
(91PS) tai kolmivaiheinen (93PS) online-järjestelmä. Se syöttää vakioitua ja
keskeytymätöntä vaihtovirtaa kriittiseen kuormaan ja suojaa sitä sähkökatkoksilta. Eaton
91/93PS:n lähtötehot perustuvat 15 kW:n tai 20 kW:n nimellistehon keskeytymättömän
sähkönsyötön tehomoduuleihin (UPM:iin).
91PS/93PS on saatavilla myös C-mallina, joka sisältää 91PS/93PS UPS 15/20 kW:n
kehikon sähköiset osat ilman akkuosastoa.
Taulukko 1. UPS-kaapin teholuokitus
UPS-kehikko
Kuva
(Piirustus 1)
UPM-kaappien määrä
Tehot
91PS 15 kW
A ja B
1
8, 10, 15 kW
91PS 30 kW
C
1 tai 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A ja B
1
8, 10, 15 tai 20 kW
93PS 40 kW
C
1 tai 2
8, 10, 15, 20, 30 tai 40
kW
91PS/93PS UPS 8-40 kW:n laitteen pääosat on näytetty kuvassa 2. Pääosat ovat
seuraavat:
1. Ohjauspaneeli
2. Oven salpa
3. Tehomoduuli (UPM)
4. Sisäinen akku (ei C-malleissa)
5. Tietoliikennealue
6. Tulokytkin
7. Akun katkaisija
8. Huolto-ohituskytkin (valinnainen)
.
VAARA
UPS:ssä on hengenvaarallisia jännitteitä.
Työt UPS:n sisäpuolella saa suorittaa vain valtuutettu Eatonin asiakaspalveluinsinööri tai
Eatonin valtuuttama pätevä huoltohenkilöstö. UPS:n sisällä ei ole käyttäjän huollettavissa
olevia osia.
Katso täydelliset turvallisuusohjeet Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja
asennusoppaasta.
UPS on asennettava Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaan
suositusten mukaisesti.
Käytä seuraavia vaiheita UPS:n asentamiseksi:
34
FI
1. Luo asennussuunnitelma UPS-järjestelmälle.
2. Valmistele asennuspaikka UPS-järjestelmää varten.
3. Tarkasta UPS-kaappi ja pura pakkaus.
4. Pura UPS-kaappi lavalta ja asenna se sekä järjestelmän johdot.
5. Täydennä asennustarkistuslista.
6. Anna valtuutetun huoltohenkilökunnan suorittaa ensitoimintatarkastukset ja
yttöönotto.
HUOMAA: Käynnistys- ja toimintatarkistukset saa suorittaa vain valtuutettu Eaton
asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltohenkilöstö. Muussa
tapauksessa Takuussa määritetyt takuuehdot eivät ole voimassa.
Ennen UPS-järjestelmän asentamista on luettava ja ymmärrettävä, kuinka näitä ohjeita
käytetään asennettavassa järjestelmässä. Käytä kuvattuja menettelytapoja ja kuvia
laatiaksesi loogisen suunnitelman järjestelmän asennusta varten.
Jotta UPS-järjestelmä toimisi huipputehollaan, asennuspaikan on vastattava Eaton
91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaassa kuvattuja ympäristöä koskevia
parametreja.
Asennusympäristön on täytettävä taulukoissa 2 ja 3 annetut UPS:n paino- ja
kokovaatimukset.
UPS-kaapin mitat on näytetty kuvassa 1. Huomaa, että syvyysmitta (750 mm) sisältää
kaapeliholkit.
Taulukko 2. UPS-kaapin painot pahvipakkauksen kanssa
C-malli 8-20 kW
(Piirustus 1, kuva A)
15/20 kW:n kehikko*
(Piirustus 1, kuva B)
30/40 kW:n kehikko*
(Piirustus 1, kuva C)
Toimituspaino
98 kg
293 kg
558 kg
Asennuspaino
86 kg
280 kg
532 kg
Lattian kuormitus
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Enimmäismäärä sisäisiä akkuja on mukana kaikissa malleissa.
UPS-kaapeissa on oltava ilmanjäähdytin, jotta sisäisten komponenttien lämpötilaa voidaan
säätää. Ilman tuloaukot ovat tavallisesti kaapin etuosassa ja poistoaukot takapuolella,
katso kuva 3. Kunkin kaapin edessä ja yläpuolella on oltava tyhjää tilaa, jotta ilma pääsee
vapaasti kiertämään. Varmista, ettei UPS:ään menevän ilman lämpötila ylitä arvoa +40 °C.
Katso tuuletusvaatimukset Eaton 91PS/93PS UPS 8-40 kW:n käyt- ja asennusoppaasta.
35
FI
Taulukko 3. UPS-kaapin ympärille vaadittu vähimmäistila
15/20 kW:n kehikko
(Piirustus 1,
kuvat A ja B)
30/40 kW:n kehikko
(Piirustus 1,
kuva C)
Kaapin yläpuoli
500 mm
500 mm
Kaapin etupuoli
500 mm
650 mm
Kaapin takapuoli
150 mm
250 mm
Kaapin sivu
0 mm
0 mm
UPS-järjestelmän käytön suositeltu ympäristölämpötila ja kosteus on esitetty kuvissa 4.1 ja
4.2. VRLA-akkujen käyttöiän maksimoimiseksi ympäristön lämpötilaksi suositellaan +20 °C
- +25 °C.
Taulukko 4. Suositellut moniydinkaapelien ja sulakkeiden vähimmäiskoot tasasuuntaaja- ja
ohitustulolle sekä UPS-lähtökaapeleille (kolmivaihetulo, kolmivaihelähtö)
93PS UPS:n teholuokitus (kW)
8
10
15
20
30
40
Kaapeli [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Tasasuuntaajan sulake [A]
20
20
32
40
63
80
Ohituksen sulake [A]
20
20
32
40
63
80
PE-kaapeli [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Johtimen enimmäispoikkipinta-ala
20 kW:n kehikko ja 20 kW:n C-malli: säikeetön johto 16
mm
2
, punottu johto pääteliittimellä: 10 mm
2
40kW:n kehikko ja 20 kW:n C-malli: säikeetön johto 70
mm
2
, punottu johto pääteliittimellä: 50 mm
2
Taulukko 5. Suositellut moniydinkaapelien ja sulakkeiden vähimmäiskoot tasasuuntaaja- ja
ohitustulolle sekä UPS-lähtökaapeleille (kolmivaihetulo, yksivaihelähtö)
91PS UPS:n teholuokitus (kW)
8
10
15
20
30
Tasasuuntaajan kaapeli [mm
2
]*
2,5
4
10
10
16
Tasasuuntaajan sulake [A]
20
20
32
40
63
Ohitus, lähtökaapeli [mm
2
]
10
16
25
35
70
Ohituksen sulake [A]
50
63
80
100
160
PE-kaapeli [mm
2
]
10
16
16
16
35
Johtimen enimmäispoikkipinta-ala, 15
kW:n kehikko ja 15 kW:n C-malli
Tasasuuntaaja: säikeetön johto 16 mm
2
,
punottu johto pääteliittimellä: 10 mm
2
Ohitus/lähtö: säikeetön johto 70 mm
2
, punottu
johto pääteliittimellä: 50 mm
2
36
FI
91PS UPS:n teholuokitus (kW)
8
10
15
20
30
Johtimen enimmäispoikkipinta-ala, 30
kW:n kehikko
Tasasuuntaaja: säikeetön johto 70 mm
2
,
punottu johto pääteliittimellä: 50 mm
2
Ohitus/lähtö: säikeetön johto 95 mm
2
, punottu
johto pääteliittimellä: 95 mm
2
HUOMAUTUS
Varmista, että UPS-järjestelmän tuloliittimien mahdollinen oikosulkuvirta ei ylitä
järjestelmän tyyppikilvessä ilmoitettua ehdollista oikosulkuvirtaa.
Taulukko 6. Ulkoisen akuston suositellut kaapelin ja sulakkeen vähimmäiskoot
UPS-teholuokitus (kW)
8
10
15
20
30
40
Pos. ja neg. linja [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Akun sulake [A]
63
63
63
63
160
160
PE-kaapeli [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Johtimen
enimmäispoikkipinta-ala
15/20 kW:n kehikko, C-malli ja 30/40 kW:n kehikko erillisellä akulla:
säikeetön johto: 25 mm
2
, punottu johto pääteliittimellä: 16 mm
2
30/40 kW:n kehikko yleisakulla: säikeetön johto: 90 mm
2
, punottu
johto pääteliittimellä: 70 mm
2
Katso nimellis- ja enimmäisvirtatiedot nimellisteholla ja -jännitteellä Eaton 91PS/93PS UPS
8-40 kW:n käyttö- ja asennusoppaasta.
Ulkoisessa erillisessä akkuvaihtoehdossa on kaksi erillistä liitintä molemmille akustoille
(kaapeille), katso lukua 2.3.1.
HUOMAA: Tämän tuotteen mukana ei toimiteta ulkoista ylivirtasuojaa, mutta sellainen on
sääntöjen mukaan pakollinen. Katso johdotusvaatimukset kohdasta Taulukko 4 ja 5.
Mahdollisesti tarvittavan lukittavan lähtökatkaisulaitteen toimittaa käyttäjä.
Taulukko 7. UPS-virtakaapeliliittimien kiristysmomentit
UPS-kehikko
Toiminto
Kiristysmomentti Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: akku +/-
3
PE (maa)
10 Nm 16-35 mm
2
johtoon
6 Nm 4-10 mm
2
johtoon
4 Nm 2,5 mm
2
johtoon
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: akku +/-
6
PE (maa)
10 Nm 16-35 mm
2
johtoon
6 Nm 4-10 mm
2
johtoon
4 Nm 2,5 mm
2
johtoon
91PS 15 kW
X1
1.6
37
FI
UPS-kehikko
Toiminto
Kiristysmomentti Nm
X2, X3
7
X4
3
PE (maa)
10 Nm 16-35 mm
2
johtoon
6 Nm 4-10 mm
2
johtoon
4 Nm 2,5 mm
2
johtoon
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (maa)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Toimi
Kyllä/Ei
Kaikki pakkausmateriaalit ja pidikkeet on poistettu kustakin kaapista.
Jokainen kaappi UPS-järjestelmässä on sijoitettu asennuspaikkaansa.
Kaapin maadoitus-/asennussarja on asennettu minkä tahansa kahden toisiinsa pultein
kiinnitetyn kaapin väliin.
Kaikki johdot ja kaapelit on asianmukaisesti reititetty UPS:ään ja mahdollisiin
lisäkaappeihin.
Kaikki virtajohdot on asianmukaisesti mitoitettu ja liitetty.
Nollajohtimet on asennettu tai liitetty maahan vaatimusten mukaisesti.
Maadoitusjohto on asennettu asianmukaisesti.
Akkukaapelit on liitetty ja kytketty akun liittimiin.
Akun rinnakkaislaukaisimen ja Aux (lisälaite) -koskettimen signaalijohdot on liitetty
UPS:stä akkukatkaisijaan.
LAN-haarajohdot on asennettu.
Kaikki LAN-liitännät on tehty.
Ilmastointivarusteet on asennettu, ja ne toimivat asianmukaisesti.
Alue ja asennettu UPS-järjestelmä ovat puhtaat ja pölyttömät (UPS:n asennus
suositellaan tehtäväksi vaakasuoralle tietokoneille ja elektronisille laitteille sopivalle
lattialle).
UPS:n ja muiden kaappien ympärillä on riittävä työtila.
Kaikkien UPS:ien ympärillä on riittävä valaistus.
230 V:n vaihtovirtahuoltopistorasia on sijoitettu enintään 7,5 metrin päähän UPS:stä.
Etähätäpysäytyskytkin (REPO-kytkin) on asennettu sille tarkoitettuun paikkaan, ja sen
johdot on liitetty UPS-kaapin sisäpuolelle.
Jos hätäpysäytyskytkintä (EPO) käytetään NC-kokoonpanossa, hyppyjohdin on
asennettu EPO-nastojen 1 ja 2 välille.
(VALINNAINEN) Hälytysreleiden ja signaalilähtöjen johdot on asennettu
asianmukaisesti.
(VALINNAINEN) Akun etäirrotusohjaus on kiinnitetty ja asennettu sille tarkoitettuun
paikkaan, ja sen johdot on liitetty UPS- ja akkukaapin sisäpuolelle.
(VALINNAINEN) Lisävarusteet on asennettu niille tarkoitettuihin paikkoihin, ja niiden
johdot on liitetty UPS-kaapin sisäpuolelle.
Käynnistys- ja toimintatarkistukset on suorittanut valtuutettu Eaton
asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltoinsinööri.
38
FI
UPS:n pakkauksesta ja lavalta poistaminen on näytetty kuvissa 9.1-9.8.
Tarkista ennen UPS:n pakkauksesta ja lavalta poistamisen aloittamista TipNTell- ja
DropNTell-osoitin pakkauksen pinnalla. Jos laite on kuljetettu oikein pystyasennossa,
osoitin on muuttumaton. Jos TipNTell-osoitinnuoli on kokonaan sininen tai DropNTell-
osoittimen nuolen pää(t) on/ovat musta(t), ota yhteys asianomaisiin osapuoliin
epäasiallisen kuljetuksen raportoimiseksi.
UPS-kaappi on pultattu puulavaan kuljetusta varten. Ennen kuin poistat kaapin lavalta,
käytä trukkia tai muuta tavarankäsittelylaitetta kaapin siirtämiseen asennusalueelle.
VAROITUS
UPS-kaappi on painava. Jos pakkauksen purkamiseen liittyviä ohjeita ei noudateta
tarkasti, kaappi saattaa keikahtaa kumoon ja aiheuttaa vakavia loukkaantumisia.
Älä kallista UPS-kaappia yli 10° pystysuorasta asennosta tai kaappi saattaa kaatua.
HUOMAA: Kun olet poistanut kuljetuskiinnittimet, siirrä yksikkö välittömästi pois
kuormalavalta.
Kun olet poistanut kuljetuskiinnittimet ja vetänyt tasausjalat sisään, älä käytä trukkia
yksikön siirtämiseen sen ollessa edelleen kuormalavalla. Huomaa, että UPS:n kaappi on
raskas ja sen alla on pyörät.
Jos kaappi otetaan pois alkuperäisestä asennuspaikastaan ja siirretään uuteen sijaintiin
kuormalavalla, laske tasausjalkoja, kunnes kaappi ei ole enää pyörien varassa ja kiinnitä
kuljetuskiinnittimet kaappiin ja kuormalavaan.
Asiakkaan on toimitettava johdot UPS:n liittämiseksi paikalliseen virtalähteeseen.
Paikallisen pätevän sähköasentajan on suoritettava UPS:n asennus. Asennustarkastus ja
UPS:n ensikäyttöönotto samoin kuin lisäakkukaapin asennus on annettava valtuutetun
Eaton asiakaspalveluinsinöörin tai Eatonin valtuuttaman huoltohenkilöstön suoritettavaksi.
UPS:n asennus on näytetty kuvissa 10.1-10.5.
UPS:n virtakaapeliliittimet on näytetty kuvissa 6.1 (91PS 15 kW:n kehikko), 6.2 (93PS 20
kW:n kehikko), 7.1 (91PS 30kW:n kehikko yleisakun kanssa), 7.2 (91PS 30kW:n kehikko
erillisen akun kanssa), 8.1 (93PS 40kW:n kehikko yleisakun kanssa) ja 8.2 (93PS 40kW:n
kehikko erillisen akun kanssa).
X1
Tasasuuntaajan tulo
X4/-
Ulkoinen akku -
X2
Ohituksen tulo
TB20
Ulkoinen akkukatkaisija
X3
UPS-lähtö
TB21
Ulkoinen akkukatkaisija
X4/+
Ulkoinen akku +
PE
Suojamaadoitus
UPM2
(erillinen akku)
39
FI
UPS:n tietoliikenneliittimet on näytetty kuvissa 5.1 ja 5.2. Liittimet ovat seuraavat:
1. TB11, ei käytössä
2. TB10, ei käytössä
3. TB9, ei käytössä
4. TB8, ulkoinen CAN-
liitäntä
5. TB7, ulkoinen CAN
6. TB6, tilatietoväylä
7. USB1, USB-isäntä
(liitäntä lisävarusteisiin)
8. USB2, USB-laite (liitäntä
tietokoneeseen)
9. MiniSlot 1
10. TB1, signaalitulo 1-5
11. TB2, ei käytössä
12. TB3, ei käytössä
13. COM-sarjaportti RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, relelähtö
Jos asennat asiakkaan toimittamaa akkujärjestelmää, asenna akkujärjestelmä akun ja
akkujärjestelmän valmistajan ohjeiden ja kaikkien soveltuvien kansallisten
asennussääntöjen ja määräysten mukaisesti.
Katso akun tekniset tiedot Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta.
91PS/93PS 8-40 kW:n UPS-yksiköt on aina varustettu sisäisellä akkukatkaisijalla, joka
vaikuttaa vain UPS:n sisäisiin akkuihin (paitsi C-malli, jossa sisäistä akkukatkaisijaa
voidaan käyttää ulkoisiin akkuihin). Ulkoinen akkukatkaisija on olennaisen tärkeä osa
ulkoista akkukaappia tai telinettä ja se on sijoitettava siihen. Signaalikaapelointi on tärkeää
ulkoisen akkukatkaisijan kanssa.
Sekä sisäinen että ulkoinen akkukatkaisija voidaan laukaista (laittaa pois päältä)
virroittamalla sen rinnakkaislaukaisukela. Ulkoisten akkukatkaisijoiden
rinnakkaislaukaisukelat virroitetaan (ohjataan) liittimien TB20 ja TB21 läpi (TB21
saatavissa vain 8-40 kW UPS:sä erillisellä akkukonfiguraatiolla). Rinnakkaislaukaisukelan
oletusjännite on 24 VDC.
Akkulaukaisun johdotus on näytetty kuvassa 11. Osat ovat seuraavat:
A
Ulkoinen akkukatkaisija
3
Nasta 3, AUX-kontakti
1
Nasta 1, rinnakkaislaukaisukela +
4
Nasta 4, AUX-kontakti, paluu
2
Nasta 2, rinnakkaislaukaisukela -
Katso ulkoisen akkukaapin ja akkujen virtakaapeloinnin asennusohjeet Eaton 91PS/93PS
UPS 8-40 kW:n käyttö- ja asennusoppaasta ja ulkoisen akkukaapin mukana toimitetusta
ohjekirjasta. Maadoita ulkoinen akkukaappi / asiakkaan toimittama akkujärjestelmä PE-
liittimeen 17.
EPO on liitettävä UPS:n yläetupaneelin EPO-liittimeen. EPO-kytkimen liitännät on näytetty
kuvassa 12.
Katso liitäntäkytkentöjen asennustiedot Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja
asennusoppaasta.
UPS:n standardiominaisuutena on yksi relekontakti yleistarkoitukseen. Lisäksi on
saatavissa hälytyskosketin. Relelähtökonfiguraatiot on näytetty kuvassa 13.
40
FI
Sekä normaalisti auki olevan että normaalisti kiinni olevan koskettimen käyttö on
mahdollista. Jos koskettimen tila muuttuu normaaliksi määrittämästäsi tilasta, lähetetään
signaali. Voit yhdistää tämän koskettimen tiloissasi oleviin laitteistoihin (kuten valoon tai
hälytyssummeriin), jotta tiedät, kun UPS-hälytys on aktiivinen.
HUOMAA: Koskettimia käytettäessä 30 VAC (RMS) ja 30 VDC 5 A:n virralla eivät saa
ylittyä.
Katso 91PS/93PS UPS rinnakkaisjärjestelmien johdotustiedot Eaton 93PS UPS 8-40 kW:n
käyttö- ja asennusoppaasta.
41
SV
1
FARA
Viktiga säkerhetsanvisningar!
Spara dessa instruktioner!
Detta dokument förser dig med viktiga säkerhetsinstruktioner och en kort instruktion för hur
du undersöker UPS-leveransen och hur man installerar UPS:en. Denna snabbguide är
endast avsedd att användas som en installationschecklista på plats.
Dokumentets avsedda målgrupp är erfarna medarbetare som planerar och genomför
installationen av UPS:en.
FARA
Innan du arbetar med UPS:en, läs igenom de fullständiga installationsinstruktionerna
som återfinns i Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide.
Fullständiga instruktioner kan laddas ner från www.eaton.com/91psand93ps.
Förfaranden inuti UPS:en måste utföras av behörig servicetekniker från Eaton eller
behörig servicepersonal auktoriserad av Eaton. Det finns inga delar i UPS:en som
användaren själv kan utföra service på.
UPS:en drivs med nätström, batteri, eller förbikopplad kraft. Den innehåller komponenter
som innehåller starkström och högspänning. Ett korrekt installerat hölje är jordat IP20-
graderat mot elektriska stötar och främmande föremål. Men UPS:en är ett sofistikerat
kraftsystem och endast behörig personal får installera och serva UPS:en.
FARA
Denna UPS-enhet leder dödlig spänning.
Batterier innebär risk för elstötar och brännskador från hög kortslutningsström. Följ
säkerhetsföreskrifterna.
Batterier kan innehålla HÖG SPÄNNING eller FRÄTANDE, GIFTIGA, och EXPLOSIVA
ämnen. På grund av batteristrängen kan utgående strömuttag bära hög spänning även
r AC-försörjningen inte är ansluten till UPS:en. Läs igenom nedstäningsinstruktionerna
i Användar- och Installationsguiden.
VARNING
UPS:en drivs med en egen energikälla (batterier). Utgångsterminalerna kan vara
spänningsförande även när UPS:en inte är ansluten till någon växelströmskälla.
Reducera risken för brand eller elstötar genom att installera UPS:en i en inomhusmiljö
med kontrollerad temperatur och luftfuktighet, fri från ledande föroreningar.
Stapla inte UPS 91PS/93PS C-modell på några andra liknande skåp. Stapla ingenting
ovanpå 91PS/93PS UPS-skåpet. Om UPS 91PS/93PS C-modell installeras på en hylla,
använd nödvändiga stöd för att förhindra att UPS:en välter.
42
SV
VARNING
Omgivningstemperaturen får inte överstiga 40 °C. Använd ej UPS:en i närheten av vatten
eller hög fuktighet (maximalt 95 %). Systemet är inte avsett för utomhusbruk.
Innan du påbörjar installations- eller servicearbete, se till att alla AC- och DC-strömkällor
är frånkopplade. Ström kan komma från flera olika källor. Försäkra dig även om
systemjord / PE-kontinuitet.
I parallellkopplade system kan utgångsterminalerna vara strömförande även när UPS:en
är avstängd.
Elenergifara. För att undvika skada, ändra inte batteriets sladdar eller anslutningar.
OBS: Se till att du kopplar ifrån alla batteristrängar innan installation.
FÖRSIKTIGHET
Endast behörig servicepersonal med kunskap om batterier och nödvändiga
försiktighetsåtgärder får utföra installation eller servicearbete på batterierna. Installation-
och servicearbete på batterier är arbete med strömförande ledningar och kräver
användning av spänningsverktyg. Håll obehörig personal borta från batterierna.
Innan du installerar eller byter batterier, tänk på alla varningar, försiktighetsåtgärder och
anmärkningar gällande lämplig hantering. Koppla inte ur batterierna medan UPS:en är i
batteriläget.
Se till att dina ersättningsbatterier är av samma antal och typ som batteriet som
installerades i UPS:en från början. Se mer noggranna instruktioner på UPS:en.
Innan du ansluter eller kopplar ifrån batteriterminaler, koppla ifrån laddningskällan genom
att öppna motsvarande batteribrytare.
Undersök om batteriet har jordats av misstag. Om det är jordat, kopplar du bort
jordkabeln. Kontakt med någon del av ett jordat batteri kan innebära risk för elstötar.
Kasta batterier i enlighet med lokala krav för bortskaffning.
Kasta aldrig batterier i eld. När de utsätts för eld, kan batterier explodera.
För att minska risken för brand ska du bara ansluta till en krets med ingångskretsbrytare
klassificerade för maximal ström i enlighet med nationella och lokala
installationsbestämmelser.
För att försäkra ordentligt kylluftflöde och för att skydda personal från farlig spänning inuti
enheten, håll UPS-dörren stäng och frontpanelerna installerade.
UPS-systemet får inte installeras eller användas i närheten av gas- eller elvärmekällor.
Håll driftmiljön inom parametrarna angivna i detta dokument. UPS:ens omgivningen ska
vara obelamrad, ren, och fri från hög fuktighet.
Följ all FARA-, FÖRSIKTIGHET- och VARNING-text som återfinns på insidan och
utsidan av utrustningen.
43
SV
2
Eaton® 91PS/93PS avbrottsfria strömförsörjning (UPS) är ett verkligt online, driftssäkert,
transformatorlöst, dubbelkonverterat, stabilt, enfas- (91PS) eller trefassystem (93PS). Det
ger konditionerad och oavbruten växelström till den kritiska lasten och skyddar den mot
strömavbrott. Den nominella uteffekten för Eaton 91PS/93PS är baserad på avbrottsfria
kraftmoduler (UPM) med en märkeffekt på 15 kW eller 20 kW.
91PS/93PS finns också som C-modell, vilken består av de elektriska komponenterna från
91PS/93PS UPS 15/20 kW-ramen utan batteriutrymmet.
Tabell 1. UPS-skåpets märkeffekt
UPS-ram
Bild
(Illustration 1)
Antal UPM-enheter
Märkeffekt
91PS 15 kW
A och B
1
8, 10, 15 kW
91PS 30 kW
C
1 eller 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A och B
1
8, 10, 15 eller 20 kW
93PS 40 kW
C
1 eller 2
8, 10, 15, 20, 30 eller 40
kW
Huvuddelarna i 91PS/93PS UPS 8-40 kW visas i illustration 2. Huvuddelarna är följande:
1. Kontrollpanel
2. Dörrlås
3. Effektmodul (UPM)
4. Internt batteri (ej i C-modeller)
5. Kommunikationsområde
6. Ingångsbrytare
7. Batteribrytare
8. Serviceförbikoppling (tillval)
.
FARA
Denna UPS-enhet leder dödlig spänning.
Förfaranden inuti UPS:en måste utföras av behörig servicetekniker från Eaton eller
behörig servicepersonal auktoriserad av Eaton. Det finns inga delar i UPS:en som
användaren själv kan utföra service på.
För fullständiga säkerhetsinstruktioner, se Eaton 91PS/93PS UPS 8-40 kW Användar-
och Installationsguide.
UPS:en måste installeras enligt rekommendationerna i Eaton 91PS/93PS UPS 8-40 kW
Användar- och Installationsguide.
Installera UPS:en via följande grundläggande steg:
44
SV
1. Upprätta en installationsplan för UPS-systemet.
2. Förbered en plats för UPS-systemet.
3. Inspektera och packa upp UPS:en.
4. Packa upp och installera UPS:en, och koppla in kablarna till systemet.
5. Fyll i installationschecklistan.
6. t auktoriserad servicepersonal utföra den preliminära driftskontrollen och starten.
ANMÄRKNING: Igångsättning och driftskontroller måste utföras av en auktoriserad
servicetekniker från Eaton eller behörig servicepersonal auktoriserad av Eaton, annars blir
garantivillkoren som specificeras i Garantin ogiltiga.
Läs och förstå hur dessa instruktioner tillämpas på systemet som ska installeras innan du
installerar UPS-systemet. Använd försedda procedurer och illustrationer för att skapa en
logisk plan för installationen av systemet.
För att UPS-systemet ska fungera effektivast ska installationsplatsen uppfylla
miljöparametrarna som anges i Eaton 91PS/93PS UPS 8-40 kW Användar- och
Installationsguide.
Installationsplatsen måste uppfylla UPS vikt- och storlekskraven som anges i Tabellerna 2
och 3.
Dimensionerna för UPS-skåpet visas i illustration 1. Observera att djupdimensionen (750
mm) inkluderar kabelgenomföringar.
Tabell 2. UPS-skåp vikt med kartongförpackning
C-modell 8-20 kW
(Illustration 1, bild A)
15/20 kW-ram*
(Illustration 1, bild B)
30/40 kW-ram*
(Illustration 1, bild C)
Transportvikt
98 kg
293 kg
558 kg
Installerad vikt
86 kg
280 kg
532 kg
Golvbelastning
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Maximala interna batterier levereras med alla modeller.
UPS:en använder forcerad luftkylning för reglering av de inre komponenternas temperatur.
Som standard sitter luftintagen framtill på enheten och utgångarna på ovansidan, se
illustration 3. Lämna fritt utrymme för ordentlig luftcirkulation framför och bakom enheten.
Se till att kylluften som kommer in i UPS:en inte överskrider +40 °C. För ventilationskrav,
se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide.
45
SV
Tabell 3. Minsta spelrum för UPS-skåpet
15/20 kW-ram
(Illustration 1,
bild A och B)
30/40 kW-ram
(Illustration 1,
bild C)
Från skåpets topp
500 mm
500 mm
Från skåpets framsida
500 mm
650 mm
Från skåpets baksida
150 mm
250 mm
Från skåpets sida
0 mm
0 mm
Rekommenderad omgivande driftstemperatur och luftfuktighet för UPS-systemet visas i
illustration 4.1 and 4.2. En omgivningstemp från +20 °C till +25 °C rekommenderas för att
ge VRLA-batterierna en lång livstid.
Tabell 4. Minsta rekommenderade storlek för flerledarkabel och säkringar till likriktare och
förbikopplingsingång och UPS-utgångskablar (trefasingång, trefasutgång)
93PS UPS märkeffekt (kW)
8
10
15
20
30
40
Kabel [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Likriktare säkring [A]
20
20
32
40
63
80
Förbikoppling säkring [A]
20
20
32
40
63
80
PE-kabel [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maximal ledararea
20 kW-ram och 20 kW C-modell: solidtråd 16mm
2
, tvinnad tråd med
hylsa: 10 mm
2
40kW-ram: solidtråd 70 mm
2
, tvinnad tråd med hylsa: 50 mm
2
Tabell 5. Minsta rekommenderade storlek för flerledarkabel och säkringar till likriktare och
förbikopplingsingång och UPS-utgångskablar (trefasingång, enfasutgång)
91PS UPS märkeffekt (kW)
8
10
15
20
30
Likriktare kabel [mm
2
]
2,5
4
10
10
16
Likriktare säkring [A]
20
20
32
40
63
Förbiledning,
utgångskabel [mm
2
]
10
16
25
35
70
Förbikoppling säkring [A]
50
63
80
100
160
PE-kabel [mm
2
]
10
16
16
16
35
Maximal ledararea, 15 kW
ram och 15 kW C-modell
Likriktare: solidtråd 16 mm
2
, tvinnad tråd med hylsa: 10
mm
2
Förbiledning/utgång: solidtråd 70 mm
2
, tvinnad tråd med
hylsa: 50 mm
2
46
SV
91PS UPS märkeffekt (kW)
8
10
15
20
30
Maximal ledararea, 30 kW
ram
Likriktare: solidtråd 70 mm
2
, tvinnad tråd med hylsa: 50
mm
2
Förbiledning/utgång: solidtråd 95 mm
2
, tvinnad tråd med
hylsa: 95 mm
2
FÖRSIKTIGHET
Se till att prospektiv kortslutningsström som leder till UPS:ens ingångar är lika med eller
mindre än villkorlig kortslutningsströmmen angiven på UPS:ens typskylt.
Tabell 6. Minsta rekommenderade kabel- och säkringsstorlek för extern batteribank
UPS klassificering (kW)
8
10
15
20
30
40
Pos. & neg. ledning [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Batterisäkring [A]
63
63
63
63
160
160
PE-kabel [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maximal ledararea
15/20 kW-ram, C-modell och 30/40 kW-ram med separat batteri:
solidtråd: 25 mm
2
, tvinnad tråd med hylsa: 16 mm
2
30/40 kW-ram med vanligt batteri: solidtråd: 90 mm
2
, tvinnad tråd
med hylsa: 70 mm
2
För information om märk- och max-ström för märkeffekt och -spänning, se Eaton
91PS/93PS UPS 8-40 kW Användar- och Installationsguide.
För de externa separata batterierna finns det separata terminaler för båda batteribankerna
(skåp), se Avsnitt 2.3.1.
ANMÄRKNING: Externt överspänningsskydd ingår inte i den här produkten, men krävs
enligt bestämmelser. Se Tabellerna 4 och 5 för krav på kablar. Om en låsbar
utgångsfrånkoppling krävs ska den tillhandahållas av användaren.
Tabell 7. UPS-strömkabel terminal moment
UPS-ram
Funktion
Åtdragningsmoment Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: batteri +/-
3
PE (jord)
10 Nm för 16-35 mm
2
kabel
6 Nm för 4-10 mm
2
kabel
4 Nm för 2,5 mm
2
kabel
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: batteri +/-
6
PE (jord)
10 Nm för 16-35 mm
2
kabel
6 Nm för 4-10 mm
2
kabel
4 Nm för 2,5 mm
2
kabel
91PS 15 kW
X1
1.6
47
SV
UPS-ram
Funktion
Åtdragningsmoment Nm
X2, X3
7
X4
3
PE (jord)
10 Nm för 16-35 mm
2
kabel
6 Nm för 4-10 mm
2
kabel
4 Nm för 2,5 mm
2
kabel
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (jord)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Handling
Ja/Nej
Allt förpackningsmaterial och alla fasthållningsanordningar har tagits bort från enheterna.
UPS-systemets enheter har placerats på installationsplatserna.
En jordnings-/monteringssats för enheten har installerats mellan enheterna som satts
ihop.
Alla ledningar och kablar har dragits korrekt till UPS:en och alla extra-enheter.
Alla strömkablar är korrekt dimensionerade och anslutna.
Nolledare har installerats och anslutits till jord i enlighet med kraven.
En jordledare har installerats korrekt.
Batterikablarna är anslutna till batteriets kontakter.
Shuntfrånkoppling för batteri och Aux-kontaktsignalkabeln är anslutna från UPS:en till
batteribrytaren.
Nätverksanslutningarna har installerats.
Alla LAN-anslutningar är slutförda.
Luftkonditioneringsutrustning har installerats och fungerar korrekt.
Området kring det installerade UPS-systemet är rent och dammfritt (det är
rekommenderat att installera UPS:en på ett platå lämplig för dator- eller elektronisk
utrustning).
Det finns tillräckligt med arbetsutrymme kring UPS:en och övriga enheter.
UPS-utrustningen omges av tillräcklig belysning.
Ett 230 VAC-uttag är placerad inom 7,5 meter från UPS-utrustningen.
Fjärrnedstängning vid nödläge (REPO) är monterad på dess installationsplats och dess
kablar har dragits till UPS:en.
Om EPO används i NC-konfigurationen, installeras en jumper på EPO:n mellan stift 1
och 2.
(TILLVAL) Larmreläer och signalutgångar är korrekt inkopplade.
(TILLVAL) Kontrollen för fjärrnedstängning av batteri är monterad på dess
installationsplats och dess kablar har dragits till UPS:en och batterienheten.
(TILLVAL) Tillbehör har monterats på sin installationsplats och kablarna har dragits till
UPS:en.
Igångsättning och driftskontroller UPS:en utförs av en behörig Eaton Kundtjänst-tekniker
eller behörig servicetekniker, auktoriserade av Eaton.
48
SV
Uppackning och avlastning av UPS:en visas i illustration 9.1–9.8.
Innan du börjar packa upp UPS:en, kontrollera TipNTell / DropNTell-indikatorerna på
paketets yta. Om utrustningen har transporterats i korrekt upprätt position bör indikatorerna
vara intakta. Om TipNTell-indikatorpilen har blivit blå eller om pilhuvudet(ena) på
DropNTell-indikatorn är svart, kontakta lämpliga parter att rapportera olämplig transport.
För transportändamål är UPS-skåpet fastbultat på en träpall. Innan du lastar av skåpet från
pallen, använd en gaffeltruck eller någon annan form av utrustning för materialhantering för
att flytta skåpet till installationsplatsen.
VARNING
UPS:en är tung. Om uppackningsanvisningarna inte följs noggrant kan enheten välta och
orsaka allvarliga personskador.
Luta inte UPS:en mer än 10 grader från vertikal position, i annat fall kan enheten tippa.
ANMÄRKNING: När du har tagit bort transportfästena, flytta direkt av enheten från
pallen.
När du har tagit bort transportfästena och dragit in fötterna, använd inte en gaffeltryck för
att flytta enheten medan den står på pallen. Observera att UPS:en är tung och att det är
hjul under skåpet.
Om du tar bort skåpet från dess ursprungliga installationsplats och flyttar det till en ny
plats på en pall, sänk ned fötterna så att skåpet inte vilar på hjulen och fäst
transportkonsolerna på skåpet och pallen.
Operatören ska tillhandahålla kablar för att ansluta UPS:en till den lokala strömkällan.
Installationen av UPS:en måste genomföras av en lokalt behörig elektriker. Kontroll av
installation och första drifttagning av UPS-enheten samt installation av ett extra batteriskåp
måste utföras av behörig servicetekniker från Eaton eller behörig servicepersonal
auktoriserad av Eaton.
Installationen av UPS:en visas i illustration 10.1-10.5.
UPS-enhetens strömkabelterminaler visas i illustration 6.1 (91PS 15 kW-ram), 6.2 (93PS
20 kW-ram), 7.1 (91PS 30kW-ram med ett vanligt batteri), 7.2 (91PS 30kW-ram med ett
separat batterialternativ), 8.1 (93PS 40kW-ram med ett vanligt batteri) och 8.2 (93PS
40kW-ram med ett separat batterialternativ).
X1
Likriktaringång
X4/-
Externt batteri -
X2
Förbikopplingsingång
TB20
Utlösning av extern
batteribrytare
X3
UPS-utgång
TB21
Utlösning av extern
batteribrytare
X4/+
Externt batteri +
PE
Skyddsjord
UPM2
(separat batteri)
49
SV
UPS:ens kommunikationsterminaler visas i illustration 5.1 och 5.2. Terminalerna är enligt
följande:
1. TB11, används ej
2. TB10, används ej
3. TB9, används ej
4. TB8, extern CAN-
avslutning
5. TB7, extern CAN
6. TB6, dragbrytare buss
7. USB1, USB-värd
(anslutning till tillbehör)
8. USB2, USB-enhet
(anslutning till dator)
9. MiniSlot 1
10. TB1, signalingång 1-5
11. TB2, används ej
12. TB3, används ej
13. Seriell COM-port RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, reläutgång
Om ett batterisystem som tillhandahålls av kunden installeras, ska det installeras i enlighet
med anvisningarna från batteriets och batterisystemets tillverkare samt alla relevanta
föreskrifter och bestämmelser.
För batterispecifikationer, se Eaton 91PS/93PS UPS 8-40 kW Användar- och
Installationsguide.
91PS/93PS 8-40 kW UPS-enheterna är alltid utrustade med en intern batteribrytare som
endast påverkar UPS:ens interna batterier (förutom för C-modellen, där den interna
batteribrytaren kan användas för externa batterier). Den externa batteribrytaren är en viktig
del av det externa batteriskåpet eller racket och måste placeras i den. Med den externa
batteribrytaren, är signalkablar är viktiga.
Både interna och externa batteribrytare kan utlösas (stängas av) genom aktivering av dess
shuntutlösningsspole. Shuntutlösspolar hos externa batteribrytare aktiveras (kontrolleras)
genom kontakter TB20 och TB21 (TB21 finns endast i 8-40 kW UPS med separat
batterikonfiguration). Standard spänning för shuntutlösningsspolen är 24 VDC.
Batteriutlösning ledningar visas i illustration 11. Delarna är enligt följande:
A
Extern batteribrytare
3
Stift 3, AUX-kontakt
1
Stift 1, shuntutlösspole +
4
Stift 4, AUX-kontakt
återgång
2
Stift 2, shuntutlösspole -
För instruktioner om hur du installerar externa batteriskåpet och batterikablage, se Eaton
91PS/93PS UPS 8-40 kW Användar- och Installationsguide och bruksanvisningen som
medföljer externa batteriskåp. Jorda det externa batteriskåp / kund-medföljande
batterisystemet till PE terminalen 17.
EPO är ansluten till UPS:ens frontpanel, på kontakten EPO. Anslutningarna för EPO-
omkopplaren visas i illustration 12.
För information om installation av anslutningar till gränssnittet, se Eaton 91PS/93PS UPS
8-40 kW Användar- och Installationsguide.
50
SV
En reläkontakt för allmänna ändamål är standard på UPS:en. Det finns också en
larmkontakt. Relänas utgångskonfigurationer visas i illustration 13.
Du kan välja en normalt sluten eller normalt öppen kontakt. En signal avges om kontaktens
status ändras från statusen som du angav som normal. Du kan ansluta den här kontakten
till utrustning i din fastighet (t.ex. en lampa eller akustisk larmfunktion) så kan du få reda på
när ett larm aktiverats på UPS:en.
ANMÄRKNING: Kontakter bör inte användas vid mer än maximalt 30 VAC (RMS) och 30
VDA vid högst 5 A.
För information kabeldragning i parallella 91PS/93PS UPS-system, se Eaton 91PS/93PS
UPS 8-40 kW Användar- och Installationsguide.
51
NO
1
FARE
Viktige sikkerhetsanvisninger!
Ta vare på denne bruksanvisningen!
Dette dokumentet inneholder viktige sikkerhetsanvisninger for hvordan du undersøker
UPS-leveransen og hvordan UPS-en installeres. Denne hurtigveiledningen er bare ment å
bli brukt som en installasjonssjekkliste på stedet.
Det tiltenkte publikum av dette dokumentet er erfarne fagfolk som planlegger og utfører
installasjonen av UPS-en.
FARE
Før du utfører arbeid på UPS-en, les alle installasjonsanvisningene som er inkludert i
bruker- og installasjonsveiledningen for Eaton 91PS/93PS 8-40 kW UPS.
De komplette anvisningene er tilgjengelige for nedlasting på
www.eaton.com/91psand93ps.
Operasjoner inne i UPS-en må gjøres av en autorisert servicetekniker fra Eaton eller av
kvalifisert servicepersonell som er autorisert av Eaton. Ingen av de innvendige delene
kan repareres av brukeren.
UPS-en bruker strømnettet, batteri eller bypass-strøm. UPS-en inneholder komponenter
som er ladet med høy strøm og spenning. Et korrekt montert skap er jordet og IP20-
klassifisert mot elektrisk støt og fremmedlegemer. Imidlertid er UPS-en en avansert
strømkilde og skal kun installeres og repareres av kvalifisert personell.
FARE
Spenningen i UPS-en kan elektrisk støt med døden til følger.
Batteriene utgjør risiko for elektrisk støt eller brannsår fra høye kortslutningsstrømmer.
Følg forholdsreglene.
Batterier kan ha HØYE SPENNINGER, og ETSENDE, GIFTIGE og EKSPLOSIVE stoffer.
På grunn av batteristrengen, kan utgangsmottakerne bære høy spenning, selv når
strømtilførselen ikke er koblet til UPS-en. Les nedstengingsinstruksjonene i bruker- og
installasjonsveiledningen.
ADVARSEL
UPS-en har en egen kraftforsyning (batterier). Strømutgangen kan være strømsatt selv
etter at UPS-en er koblet fra nettspenningen. For å redusere faren for brann eller
elektrisk støt, bør UPS-en settes i et innemiljø som er temperatur- og fuktighetsregulert,
og fritt for ledende kontaminasjoner.
Ikke stable 91PS/93PS UPS C-modellskapet oppå noe/noen annet/andre lignende skap.
Ikke stable noe oppå 91PS/93PS UPS-skapet. Hvis 91PS/93PS UPS C-modellskapet
installeres på en hylle, må du bruke nødvendig støtte for å forhindre at UPS-en velter
eller faller ned.
52
NO
ADVARSEL
Romtemperaturen må ikke overskride 40 °C. UPS-en må ikke brukes i nærheten vann
eller i omgivelser med høy luftfuktighet (maks 95%). Enheten er ikke beregnet for
utendørs bruk.
Før det utføres installasjon eller service, må alle AC og DC-strømkilder være koblet fra.
Flere kilder kan være strømsatt. Sjekk også systemets jording / PE-leder.
I et parallelt system kan utgangene være strømsatt selv når UPS-en er slått av.
Fare for elektrisk støt. For å unngå skade, ikke forsøk å gjøre endringer på batterikablene
eller koblingene.
VIKTIG: Pass på at du kobler fra alle batteristrengene før installasjon.
FORSIKTIG
Det er kun kvalifisert personell med kunnskap om batterier og relevante forholdsregler
som kan utføre installasjon av eller service på batteriene. Installasjons- og servicearbeid
på batterier er strømdrevet arbeid og krever bruk av spenningsverktøy. Uvedkommende
må holdes borte fra batteriene.
Før du installerer eller skifter batterier, må du ta i betraktning alle advarsler,
forsiktighetsregler og merknader om forsvarlig håndtering. Ikke koble fra batteriene når
UPS-en er i batterimodus.
Påse at de nye batteriene er av samme antall og type som det originale batteriet i UPS-
en. Se detaljerte instruksjoner om UPS-en.
Før du kobler til eller fra batteriterminalene, må ladekilden kobles med korresponderende
batteribryter.
Undersøk om batteriet er utilsiktet jordet. Hvis batteriet er jordet, må jordingspunktet
kobles fra. Dersom du kommer i kontakt med et batteri som er jordet, kan det føre til
elektrisk støt.
Batteriene må avhendes i henhold til lokale avfallsforskrifter.
Ikke kast batterier i brannkilder. Batterier kan eksplodere dersom de utsettes for flammer.
For å redusere risikoen for brann, koble kun til en krets som er utstyrt med en
inngangseffektbryter med høyeste nominell strøm i samsvar med nasjonale og lokale
forskrifter for installasjon.
For å sikre tilstrekkelig ventilasjon og for å beskytte personer fra farlige spenninger inne i
enheten, må døren på UPS-en holdes lukket og frontpanelene være på plass.
Ikke installer eller bruk UPS-systemet i nærheten av gass eller elektriske varmekilder.
Driftsmiljøet må opprettholdes innenfor rammene som er beskrevet i dette dokumentet.
Hold omgivelsene rundt UPS-en ryddige, rene og fri for fuktighet.
All merking med FARE, FORSIKTIG og ADVARSEL på innsiden og utsiden av utstyret
må følges.
53
NO
2
Eaton® 91PS/93PS avbruddsfri strømforsyning (UPS-enheten) er et ekte online,
transformatorløs, dobbeltkonverterende, solid-state, enfaset (91PS) eller trefaset (93PS)
system for kontinuerlig drift. Det leverer filtrert og avbruddsfri AC-strøm til kritisk last og
beskytter den mot strømbrudd. Eaton 91PS/93PS utgangseffekt er basert på avbruddsfrie
strømmoduler (UPM-er) med 15 kW eller 20 kW nominell effekt.
91PS/93PS er også tilgjengelig som en C-modell, som består av den elektriske delen av
91PS/93PS UPS 15/20 kW-rammen uten batterirommet.
Tabell 1.Klassifiseringer for UPS-skapet
UPS-ramme
Bilde
(Illustrasjon 1)
Antall UPM-er
Klassifiseringer
91PS 15 kW
A og B
1
8, 10, 15 kW
91PS 30 kW
C
1 eller 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A og B
1
8, 10, 15 eller 20 kW
93PS 40 kW
C
1 eller 2
8, 10, 15, 20, 30 eller 40
kW
Hoveddelene av 91PS/93PS UPS 8-40 kW er vist i illustrasjon 2. Hoveddelene er som
følger:
1. Kontrollpanel
2. Dørlås
3. Strømmodul (UPM)
4. Internt batteri (ikke i C-modeller)
5. Kommunikasjonsseksjon
6. Inngangsbryter
7. Batteribryter
8. Bypass-bryter (MBS) (valgfritt)
.
FARE
Spenningen i UPS-en kan elektrisk støt med døden til følger.
Operasjoner inne i UPS-en må gjøres av en autorisert servicetekniker fra Eaton eller av
kvalifisert servicepersonell som er autorisert av Eaton. Ingen av de innvendige delene
kan repareres av brukeren.
For komplette sikkerhetsanvisninger, se bruker- og installasjonsveiledningen til Eaton
91PS/93PS UPS 8-40 kW.
UPS-en må installeres i henhold til anbefalingene i bruker- og installasjonsveiledningen til
Eaton 91PS/93PS UPS 8-40 kW.
Utfør følgende trinn i oppgitt rekkefølge for å installere UPS-systemet:
54
NO
1. Lag en installasjonsplan for UPS-systemet.
2. Klargjør stedet der UPS-systemet skal installeres.
3. Sjekk og pakk ut UPS-skapet.
4. Ta ut og installer UPS-skapet og ledningsanlegget.
5. Fullfør installasjonssjekklisten.
6. Få autorisert servicepersonell til å utføre forberedende funksjonskontroll og idriftsettelse.
MERK: Oppstart og operasjonelle kontroller må utføres av en autorisert Eaton-
servicetekniker eller kvalifisert servicepersonell som er autorisert av Eaton. Unnlatelse av å
etterleve dette vil ugyldiggjøre garantibetingelsene spesifisert i garantien.
Før UPS-systemet installeres, må du lese gjennom og være innforstått med hvordan disse
instruksjonene anvendes for systemet som skal installeres. Bruk de medfølgende
fremgangsmåtene og illustrasjonene for å utarbeide en logisk plan for installasjon av
systemet.
For at UPS-systemet skal kunne operere så effektivt som mulig, må installasjonsstedet
oppfylle de miljømessige verdiene som er beskrevet i bruker- og installasjonsveiledningen
til Eaton 91PS/93PS UPS 8-40 kW.
Installasjonsmiljøet må oppfylle vekt- og størrelseskravene til UPS-en oppgitt i tabellene 2
og 3.
Dimensjonene av UPS-skapet er vist i illustrasjon 1. Være oppmerksom på at
dybdedimensjonen (750 mm) inkluderer kabelgjennomføringer.
Tabell 2. Vekt på UPS-skap med pappemballasje
C-modell 8-20 kW
(Illustrasjon 1,
bilde A)
15/20 kW ramme*
(Illustrasjon 1,
bilde B)
30/40 kW ramme*
(Illustrasjon 1,
bilde C)
Fraktvekt
98 kg
293 kg
558 kg
Vekt installert
86 kg
280 kg
532 kg
Gulvbelastning
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Maksimalt antall interne batterier følger med alle modellene.
UPS-skap bruker aktiv luftkjøling å regulere den innvendige komponenttemperaturen. Som
standard er luftinnløpet foran på skapet og luftutløpet er bak, se illustrasjon 3. La det være
en klaring foran og bak hvert skap for å oppnå en god luftsirkulasjon. Kontroller at
kjøleluften som kommer inn i UPS-en ikke overstiger +40 °C. For ventilasjonskrav, se
bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW.
55
NO
Tabell 3. Minimumsklaring for UPS-skap
15/20 kW ramme
(Illustrasjon 1,
bildene A og B)
30/40 kW ramme
(Illustrasjon 1,
bilde C)
Fra toppen av skapet
500 mm
500 mm
Fra fronten av skapet
500 mm
650 mm
Fra baksiden av skapet
150 mm
250 mm
Fra siden av skapet
0 mm
0 mm
Den anbefalte omgivelsestemperaturen og luftfuktigheten for UPS-systemet er vist i
illustrasjonene 4.1 og 4.2. Det anbefales en omgivelsestemperatur på mellom 20 °C og
+25 °C for å oppnå en optimal levetid på VRLA-batteriene.
Tabell 4.Minimum anbefalt flerlederkabel og sikringsstørrelser for likeretter og bypass-inngang og
kabler for UPS-utgang (trefaseinngang, trefaseutgang)
93 PS UPS nominell effekt
(kW)
8
10
15
20
30
40
Kabel [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Likerettersikring [A]
20
20
32
40
63
80
Bypass-sikring [A]
20
20
32
40
63
80
PE-kabel [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maksimalt ledertverrsnitt
20 kW-ramme og 20 kW C-modell: massiv tråd 16 mm
2
, flettet
ledning med endehylse: 10 mm
2
40kW-ramme: massiv tråd 70 mm
2
, flettet ledning med endehylse:
50 mm
2
Tabell 5.Minimum anbefalt flerlederkabel og sikringsstørrelser for likeretter og bypass-inngang og
kabler for UPS-utgang (trefaseinngang, enfaseutgang)
91PS UPS nominell effekt
(kW)
8
10
15
20
30
Likeretterkabel [mm
2
]
2,5
4
10
10
16
Likerettersikring [A]
20
20
32
40
63
Bypass, utgangskabel [mm
2
]
10
16
25
35
70
Bypass-sikring [A]
50
63
80
100
160
PE-kabel [mm
2
]
10
16
16
16
35
56
NO
91PS UPS nominell effekt
(kW)
8
10
15
20
30
Maksimalt tverrsnitt leder,
15 kW-ramme og 15 kW C-
modell
Likeretter: massiv ledning 16 mm
2
, flettet ledning med
endehylse: 10 mm
2
Likeretter/utgang: massiv ledning 70 mm
2
, flettet
ledning med endehylse: 50 mm
2
Maksimalt tverrsnitt leder,
30 kW-ramme
Likeretter: massiv ledning 70 mm
2
, flettet ledning med
endehylse: 50 mm
2
Likeretter/utgang: massiv ledning 95 mm
2
, flettet
ledning med endehylse: 95 mm
2
FORSIKTIG
Påse at prospektiv kortslutningsstrøm på UPS-inngangsterminalene er lik eller mindre
enn betinget kortslutningsstrøm som er oppgitt på klassifiseringsskiltet på UPS-en.
Tabell 6. Minimum anbefalte kabeldimensjoner og sikringsstørrelser for ekstern batteribank
UPS nominell effekt (kW)
8
10
15
20
30
40
Pos. og neg. linje [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Batterisikring [A]
63
63
63
63
160
160
PE-kabel [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maksimalt ledertverrsnitt
15/20 kW-ramme, C-modell og 30/40 kW-ramme med separat
batteri: massiv tråd: 25 mm
2
, flettet ledning med endehylse: 16 mm
2
30/40 kW-ramme med fellesbatteri: massiv tråd: 90 mm
2
, flettet
ledning med endehylse: 70 mm
2
For informasjon om nominelle og maksimale strømmer for nominell effekt og spenning, se
bruker- og installasjonsveiledning til Eaton 91PS/93PS UPS 8-40 kW.
For alternativet med separat eksternt batteri, finnes det egne terminaler for begge
batteribankene (kabinett), se seksjon 2.3.1.
MERK: Det er ikke eksternt overspenningsvern med dette produktet, men kreves ihht.
forskrifter. Se tabellene 4 og 5 for krav til kabling. Hvis det er behov for en låsbar
skillebryter på utgangen, må brukeren selv sørge for dette.
Tabell 7. Tiltrekkingsmoment for strømterminalene
UPS-ramme
Punkt
Tiltrekningsmoment Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: batteri +/-
3
PE (jord)
10 Nm for 16-35 mm
2
kabel
6 Nm for 4-10 mm
2
kabel
4 Nm for 2,5 mm
2
kabel
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: batteri +/-
6
57
NO
UPS-ramme
Punkt
Tiltrekningsmoment Nm
PE (jord)
10 Nm for 16-35 mm
2
kabel
6 Nm for 4-10 mm
2
kabel
4 Nm for 2,5 mm
2
kabel
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (jord)
10 Nm for 16-35 mm
2
kabel
6 Nm for 4-10 mm
2
kabel
4 Nm for 2,5 mm
2
kabel
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (jord)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Handling
Ja/Nei
All emballasje og beskyttelse er fjernet fra hvert av skapene.
Hvert skap i UPS-systemet er plassert på installasjonssted.
Det er installert jordingssett mellom eventuelle skap som er boltet sammen.
Alle kabelkanaler og kabler er rutet til UPS-en og eventuelle ekstraskap.
Alle strømkabler er av riktig dimensjon og terminert.
Nøytralledere er koblet og jordet i henhold til kravene.
Jordingsledning er korrekt koblet.
Batterikablene er terminert og koblet til batterikontaktene.
Signalledninger for batterishuntutløser og hjelpekontakt er koblet mellom UPS og
batteribryter.
Nettverkskabling er lagt opp.
Alle nettverkskabler er tilkoblet.
Ventilasjonsanlegg er installert og fungerer som det skal.
Området rundt det installerte UPS-systemet er rent og støvfritt (det anbefales at UPS-en
installeres på et plant gulv egnet for datautstyr og elektronisk utstyr).
Det er tilstrekkelig med arbeidsområde rundt UPS-en og andre skap.
Det er tilstrekkelig med belysning rundt alt UPS-utstyret.
Det finnes et 230 VAC serviceuttak innen 7,5 meter fra UPS-utstyret.
REPO-enheten (Remote Emergency Power-off) er montert på installasjonsposisjon og
kablingen er terminert innvendig i UPS-skapet.
Hvis EPO brukes i NC-konfigurasjon, kobles det en lask på EPO mellom pinn 1 og 2.
(VALGFRITT) Alarmreléer og signalutganger er korrekt kablet.
(VALGFRITT) En ekstern batterifrakoblingskontroll er montert på installasjonsposisjon og
kablingen er terminert innvendig i UPS- og batteriskapet.
(VALGFRITT) Tilbehøret er montert på installasjonsposisjon og kablingen er terminert
innvendig i UPS-skapet.
Oppstart og driftskontroller må utføres av en autorisert servicetekniker fra Eaton eller av
58
NO
Handling
Ja/Nei
kvalifisert servicetekniker som er autorisert av Eaton.
Utpakking og løfting av UPS-enheten er vist i illustrasjonene 9.1 – 9.8.
Før du begynner å pakke ut og løfte på plass UPS-enheten, sjekk TipNTell- og DropNTell-
indikatoren på emballasjen. Hvis utstyret har blitt korrekt transportert i stående stilling, skal
indikatorene være intakt. Hvis TipNTell-indikatorpilen er fullstendig blå eller pilhodet(ene)
av DropNTell-indikatoren er sort, kan du kontakte de aktuelle parter for å rapportere
upassende transport.
For transportformål er UPS-skapet boltet fast på en trepalle. Før skapet løftes fra pallen,
må det brukes en gaffeltruck eller pallejekk for å flytte skapet til installasjonsområdet.
ADVARSEL
UPS-skapet er tungt. Hvis anvisningene for utpakking ikke overholdes nøye, kan skapet
velte og forårsake alvorlig skade.
Ikke vipp UPS-skapet mer enn 10 grader fra vertikal stilling, ellers kan det velte.
MERK: Etter at fraktbrakettene er fjernet, flytt enheten umiddelbart av pallen.
Etter at fraktbrakettene er fjernet og føttene er skrudd inn, må det ikke brukes gaffeltruck
for å flytte enheten mens den står fortsatt på pallen. Vær oppmerksom på at UPS-skapet
er tungt, og at det er hjul på undersiden.
Hvis skapet skal flyttes til et nytt sted ved hjelp av en palle, må føttene på skapet senkes
slik at skapet ikke lenger hviler på hjulene og fest fraktbrakettene til kabinettet og pallen.
Operatøren må sørge for kabling for å koble UPS-en til det lokale strømnettet. Installasjon
av UPS-en må gjøres av en autorisert elektriker lokalt. Inspeksjon etter installasjon,
idriftsettelse av UPS-systemet og installasjon av ekstra batteriskap, må utføres av en
autorisert servicetekniker fra Eaton eller av kvalifisert servicetekniker som er autorisert av
Eaton.
Installasjonen av UPS-enheten er vist i illustrasjonene 10.1-10.5.
UPS strømkabelterminalene er vist i illustrasjonene 6.1 (91PS 15 kW ramme), 6.2 (93PS
20 kW ramme), 7.1 (91PS 30 kW ramme med et felles batteri), 7.2 (91PS 30 kW ramme
med et separat batterialternativ), 8.1 (93PS 40 kW ramme med et felles batteri) og 8.2
(93PS 40 kW ramme med et separat batterialternativ).
X1
Likeretterinngang
X4/-
Eksternt batteri -
X2
Bypass-inngang
TB20
Utløsn. eksternt batteri
X3
UPS-utgang
TB21
Utløsn. eksternt batteri
X4/+
Eksternt batteri +
PE
Beskyttende jording
UPM2
(separat batteri)
59
NO
UPS-kommunikasjonsterminalene er vist i illustrasjonene 5.1 og 5.2. Terminalene er som
følger:
1. TB11, ikke i bruk
2. TB10, ikke i bruk
3. TB9, ikke i bruk
4. TB8, ekstern CAN-
terminering
5. TB7, ekstern CAN
6. TB6, pull-chain-buss
7. USB1, USB-vert
(tilkobling til tilbehør)
8. USB2, USB-enhet
(tilkobling til datamaskin)
9. MiniSlot 1
10. TB1, signalinngang 1-5
11. TB2, ikke i bruk
12. TB3, ikke i bruk
13. Seriell COM-port RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, reléutgang
Hvis kunden har et eget batterisystem som skal installeres, må batterisystemet installeres i
henhold til instruksjonene fra produsenten av batterisystemet, samt alle gjeldende
nasjonale lover og forskrifter.
For batteriets spesifikasjoner, se bruker- og installasjonsveiledningen til Eaton 91PS/93PS
UPS 8-40 kW.
91PS/93PS 8-40 kW UPS-enhetene er alltid utstyrt med en intern batteribryter, som kun
påvirker UPS-ens interne batterier (med unntak av C-modellen, hvor den interne
batteribryteren kan brukes for eksterne batterier). En ekstern batteribrytere er en
avgjørende del av et eksternt batteriskap eller rack, og må monteres sådan. Med en
ekstern batteribryter er det viktig med signalkabler.
Både interne og eksterne batteribrytere kan bli utløst (slått av) ved at shuntutløserspolen
strømsettes. Shuntutløserspolene på eksterne batteribrytere aktiveres (kontrollert)
gjennom kontaktene TB20 og TB21 (TB21 kun tilgjengelig på 8-40 kW UPS med separat
batterikonfigurasjon). Standardspenning shuntutløserspolen er 24 VDC.
Batteriutløseren er vist i illustrasjon 11. Delene er som følger:
A
Ekstern batteribryter
3
Pinn 3, hjelpekontakt
1
Pinn 1, shuntutløserspole +
4
Pinn 4, hjelpekontakt retur
2
Pinn 2, shuntutløserspole -
For instruksjoner om hvordan et eksternt batteriskap og strømtilkobling skal gjøres, se
bruker- og installasjonsveiledningen for Eaton 91PS/93PS 8-40 kW og bruksanvisningen
som følger med det eksterne batteriskapet. Det eksterne batteriskapet / kundens eget
batterisystem må jordes til PE-terminal 17.
EPO kobles til EPO-tilkoblingen på UPS-ens øverste frontpanel. Tilkoblingene av EPO-
bryteren er vist i illustrasjon 12.
For informasjon om installasjon av grensesnittforbindelser, se bruker- og
installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW.
60
NO
Det er som standard én universal relékontakt på UPS-en. Det er også en alarmkontakt.
Utgangsreléets konfigurasjoner er vist i illustrasjon 13.
Det kan brukes en Normalt lukket eller Normalt åpen kontakt. Dersom kontaktstatus endres
fra status som er angitt som normal, vil det sendes ut et signal. Denne kontakten kan
kobles til utstyr på anlegget (for eksempel lampe eller horn) for å varsle deg når en alarm
er aktiv på UPS-en.
MERK: Kontakter skal ikke brukes over maks. 30 VAC (RMS) og 30 VDC ved 5 A.
For informasjon om kobling av parallelle 91PS/93PS UPS-systemer, se bruker- og
installasjonsveiledningen for Eaton 91PS/93PS UPS 8-40 kW.
61
DA
1
FARE
Vigtige sikkerhedsoplysninger!
Gem disse anvisninger!
Dette dokument indeholder vigtige sikkerhedsinstruktioner og en kort introduktion til,
hvordan UPS-anlægget skal kontrolleres ved leveringen, og hvordan det skal installeres.
Denne Quick Guide er kun beregnet til brug som en tjekliste i forbindelse med installation
på stedet.
Dette dokument er udarbejdet til erfarent, fagkyndigt personale, som planlægger og
udfører installationen af UPS-anlægget.
FARE
Inden du udfører arbejde på UPS-anlægget, skal du læse alle
installationsinstruktionerne i bruger- og installationsvejledningen til Eaton 91PS/93PS
8-40 kW UPS.
De samlede instruktioner kan downloades på www.eaton.eu/91psand93ps.
Indgreb inde i UPS-anlægget skal udføres af en autoriseret tekniker fra Eatons
kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. Der findes
ingen indvendige dele i UPS-anlægget, som skal vedligeholdes af brugeren.
UPS-anlægget fungerer med netstrøm, batteri eller bypasseffekt. Det indeholder
komponenter, som leder høj strøm og spænding. Et korrekt installeret kabinet er
jordforbundet og IP20-klassificeret mod elektrisk stød og fremmede genstande. UPS-
anlægget er et sofistikeret strømsystem, og det må kun installeres og serviceres af
kvalificeret personale.
FARE
Dette UPS-anlæg indeholder livsfarlig spænding.
Batterierne udgør en fare for elektrisk stød eller forbrænding fra høj
kortslutningsstrøm. Overhold forholdsreglerne.
Batterier kan indeholde HØJE SPÆNDINGER og ÆTSENDE, GIFTIGE og
BRANDFARLIGE stoffer. På grund af batteristrengen kan udgangsstikkene stadig
være under høj spænding, efter at AC-strømforsyningen til UPS-anlægget er afbrudt.
Læs instruktionerne i afsnittet nedlukning i bruger- og installationsvejledningen.
ADVARSEL
UPS-anlægget strømforsynes af sin egen energikilde (batterier). Udgangsklemmerne
kan være strømførende, efter at UPS-anlægget er afbrudt fra vekselstrømkilden. For
at reducere risikoen for brand eller elektrisk stød, skal UPS-anlægget installeres i
indendørs omgivelser, hvor temperatur og fugtighed er kontrolleret. Desuden må
omgivelserne ikke indeholde ledende kontaminanter.
Stil ikke UPS 91PS/93PS C-modellens kabinet oven på et andet/andre tilsvarende
kabinet(er). Stil ikke nogen genstande oven på 91PS/93PS UPS-kabinettet. Hvis UPS
91PS/93PS C-modellens kabinet er installeret på en hylde, skal der anvendes den
nødvendige understøtning for at sikre, at UPS-enheden ikke kan vælte eller falde ned.
62
DA
ADVARSEL
Omgivelsestemperaturen må ikke overskride 40 °C. Brug aldrig UPS-anlægget i
nærheden af vand eller høj fugtighed (maks. 95 %). Systemet er ikke beregnet til
udendørs opstilling.
Inden du påbegynder installation eller service, skal du kontrollere, at alle veksel- og
jævnstrømskilder er afbrudte. Effekt kan tilføres fra flere kilder. Sørg også for tilslutning
af jordforbindelse/PE-kontinuitet.
Udgangsklemmerne kan være strømførte i et parallelt system, også efter at UPS-
anlægget er slukket.
Fare for elektricitet. Forsøg ikke at ændre på batteriets kabler eller stik. Der er fare for at
komme til skade.
VIGTIGT: Sørg for at afbryde alle batteristrenge før installationen.
FORSIGTIG
Installation og servicering af batterierne må kun udføres af servicepersonale, som har
kendskab til batterierne og de nødvendige forholdsregler. Batterierne er strømførende
og både installation og serviceopgaver kræver brug af spændingsmålere. Hold
uautoriseret personale på afstand af batterierne.
Før du installerer eller udskifter batterierne, skal du tage alle advarsler, forholdsregler
og bemærkninger angående korrekt håndtering i betragtning. Afbryd ikke batterierne,
når UPS-anlægget er i batteritilstand.
Sørg for, at dine reservebatterier har samme nummer og type som batteriet, der
oprindeligt blev installeret i UPS-anlægget. Se flere detaljer om UPS-anlægget.
Inden du tilslutter eller afbryder batteriklemmerne, skal opladekilden afbrydes ved at
åbne den relevante batterikredsafbryder.
Kontroller, om batterierne utilsigtet er jordforbundet. Hvis det er tilfældet, skal kilden til
jorden fjernes. Der er risiko for elektrisk stød ved kontakt med en hvilken som helst del
af et jordforbundet batteri.
Kassér batterierne som anvist i de lokalt gældende bestemmelser for aflevering af
affald.
Kast ikke batterierne i åben ild. Batterierne kan eksplodere, når de udsættes for åben
ild.
For at reducere risikoen for brand må tilslutningen kun udføres til en kreds, der er
forsynet med en indgangskredsafbryder med maksimale mærkestrømme i
overensstemmelse med nationale og lokale installationsregler.
For at sikre en passende afkølende luftstrøm og beskytte personalet mod farlig
spænding inde i enheden skal UPS-anlæggets dør holdes lukket, og frontpanelerne skal
være monteret.
Installer og brug ikke UPS-anlægget i nærheden af gas eller elektriske varmekilder.
Sørg for, at driftsomgivelserne opfylder parametrene, som er opført i dette dokument.
Hold UPS-anlæggets omgivelser ryddelige, rene og fri for overdreven fugt.
Overhold alle skilte med FARE-, FORSIGTIGHEDS- OG ADVARSELSSYMBOLER,
som forefindes inde i og uden på udstyret.
63
DA
2
Eaton® 91PS/93PS nødstrømforsyning (UPS) er et ægte solid state enfaset (91PS)
onlinesystem i konstant funktion, uden transformer og med dobbeltkonvertering eller et
trefaset system (93PS). Den leverer reguleret og uafbrudt vekselstrøm til kritisk udstyr og
beskytter det mod svigt i strømforsyningen. Værdierne for udgangseffekten af Eaton
91PS/93PS er baseret på uafbrudte effektmoduler (UPM'er) med en nominel værdi på 15
kW eller 20 kW.
91PS/93PS kan også fås som en C-model, der består af den elektriske del i 91PS/93PS
UPS 15/20 kW ramme uden batterirummet.
Tabel 1. Værdier for UPS-kabinet
UPS-ramme
Billede
(Figur 1)
Antal UPM’er
Værdier
91PS 15 kW
A og B
1
8, 10, 15 kW
91PS 30 kW
C
1 eller 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A og B
1
8, 10, 15 eller 20 kW
93PS 40 kW
C
1 eller 2
8, 10, 15, 20, 30 or 40
kW
Hovedkomponenterne i 91PS/93PS UPS 8-40 kW er vist i figur 2. Hovedkomponenterne er
følgende:
1. Kontrolpanel
2. Dørlås
3. Effektmodul (UPM)
4. Internt batteri (ikke i C-moduler)
5. Kommunikationsområde
6. Indgangsswitch
7. Batteriafbryder
8. Bypassswitch til brug under
vedligeholdelse (ekstraudstyr)
.
FARE
Dette UPS-anlæg indeholder livsfarlig spænding.
Indgreb inde i UPS-anlægget skal udføres af en autoriseret tekniker fra Eatons
kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. Der findes
ingen indvendige dele i UPS-anlægget, som skal vedligeholdes af brugeren.
Alle sikkerhedsinstruktioner kan findes i bruger- og installationsvejledningen til Eaton
91PS/93PS UPS 8-40 kW.
UPS-enheden skal installeres i overensstemmelse med anvisningerne i bruger- og
installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW.
Brug den følgende standardprocedure til installation af UPS-anlægget:
1. Udarbejd en installationsplan for UPS-anlægget.
64
DA
2. Forbered UPS-anlæggets installationssted.
3. Efterse og pak UPS-kabinettet ud.
4. Installer UPS-kabinettet og ledningsnettet.
5. Udfyld tjeklisten for installationen.
6. Få autoriseret servicepersonale til at udføre de indledende kontroller af driften og
første ibrugtagning.
BEMÆRK: Idriftsættelse og kontrol af driften skal udføres af en autoriseret tekniker fra
Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. I modsat
fald bortfalder garantien.
Inden du installerer UPS-anlægget, skal du læse og sætte dig grundigt ind i, hvordan disse
instruktioner gælder for det system, som du skal installere. Brug procedurerne og figurerne
til at oprettet et logisk diagram for systemets installation.
Det er nødvendigt, at installationsstedet opfylder de specifikationer for omgivelserne, som
er anført i bruger- og installationsvejledningen for Eaton 91PS/93PS UPS 8-40 kW.
Installationsmiljøet skal opfylde kravene til UPS-anlæggets vægt og størrelse som er anført
i tabel 2 og 3.
UPS-kabinettets mål er vist i figur 1. Bemærk, at målet for dybden (750 mm) er inklusive
kabelforskruninger.
Tabel 2. UPS-kabinettets vægt med papemballage
C-model 8-20 kW
(Figur 1,
billede A)
15/20 kW-ramme*
(Figur 1, billede B)
30/40 kW-ramme*
(Figur 1, billede C)
Forsendelsesvægt
98 kg
293 kg
558 kg
Installeret vægt
86 kg
280 kg
532 kg
Gulvbelastning
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
Det maksimale antal interne batterier er inkluderet for alle modeller.
UPS-kabinetterne anvender konstant luftafkøling til regulering af komponenternes
indvendige temperatur. Som standard er luftindtagene placeret på kabinettets forside, og
luftudledningerne på bagsiden, jf. figur 3. Sørg for, at der er tilstrækkeligt frirum foran og
bagved hvert kabinet til at luften kan cirkulere korrekt. Sørg for, at temperaturen for
afkølingsluften, som suges ind i UPS-enheden, ikke overstiger +40 °C. Se bruger- og
installationsvejledningen for Eaton 91PS/93PS UPS 8-40 kW for oplysninger om krav til
ventilationen.
65
DA
Tabel 3. Mindste frirum for UPS-kabinet
15/20 kW-ramme
(Figur 1,
billede A og B)
30/40 kW-ramme
(Figur 1,
billede C)
Fra kabinettets top
500 mm
500 mm
Fra kabinettets forside
500 mm
650 mm
Fra kabinettets bagside
150 mm
250 mm
Fra kabinettets side
0 mm
0 mm
Den anbefalede temperatur for USP-systemets driftsomgivelser og fugtighed er vist i figur
4.1 og 4.2. En omgivelsestemperatur på mellem +20 °C og +25 °C anbefales for at sikre
VRLA-batteriernes lange levetid.
Tabel 4. Anbefalede minima for flerlederkabler og sikringsstørrelser for ensretter og bypassindgang
og UPS-udgangskabler (modeller med 3-faset indgang, 3-faset udgang)
93PS UPS-effekt (kW)
8
10
15
20
30
40
Ledning [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Ensrettersikring [A]
20
20
32
40
63
80
Bypasssikring [A]
20
20
32
40
63
80
PE-kabel [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maks. tværsnit for leder
20 kW ramme og 20 kW C-model: massiv ledning 16 mm
2
, snoet
tråd med ferule: 10 mm
2
40 kW ramme: massiv ledning 70 mm
2
, snoet tråd med ferrule:
50 mm
2
Tabel 5. Anbefalede minima for flerlederkabler og sikringsstørrelser for ensretter og bypassindgang
og UPS-udgangskabler (3-faset indgang, 1-faset udgang)
91PS UPS-effekt (kW)
8
10
15
20
30
Ensretterindgang, kabel [mm
2
]
2,5
4
10
10
16
Ensrettersikring [A]
20
20
32
40
63
Bypass, udgangskabel [mm2]
10
16
25
35
70
Bypasssikring [A]
50
63
80
100
160
PE-kabel [mm2]
10
16
16
16
35
Maks. tværsnit for leder, 15 kW
ramme og 15 kW C-model
Ensretter: 40 kW-ramme: massiv ledning 16 mm
2
,
snoet tråd med ferrule: 10 mm
2
Bypass/udgang: massiv ledning 70 mm
2
, snoet tråd
med ferrule: 50 mm
2
66
DA
91PS UPS-effekt (kW)
8
10
15
20
30
Maks. tværsnit for leder, 30 kW-
ramme
Ensretter: 40 kW ramme: massiv ledning 70 mm
2
,
snoet tråd med ferrule: 50 mm
2
Bypass/udgang: massiv ledning 95 mm
2
, snoet tråd
med ferrule: 95 mm
2
FORSIGTIG
Sørg for, at den prospektive kortslutningsstrøm, som opstår på UPS-anlæggets
indgangsklemmer, er lig med eller mindre end den betingede kortslutningsstrøm, som
er angivet på UPS-anlæggets effektskilt.
Tabel 6. Anbefalede minimum for kabler og sikringsstørrelser for ekstern batteribank
UPS-effekt (kW)
8
10
15
20
30
40
Pos. og neg. linje [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Batterisikring [A]
63
63
63
63
160
160
PE-kabel [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maks. tværsnit for leder
15/20 kW-ramme, C-model og 30/40 kW-ramme med separat
batteri: massiv ledning: 25 mm
2
, snoet tråd med ferule: 16 mm
2
30/40 kW-ramme med fælles batteri: massiv ledning: 90 mm
2
,
snoet tråd med ferule: 70 mm
2
Oplysninger om mærkestrøm og maksimum strøm for nominel effekt og spænding kan
findes i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW.
Til den eksterne, separate batterifunktion findes separate klemmer for begge batteribanker
(kabinetter). Se afsnit 2.3.1.
BEMÆRK: Ekstern overstrømsbeskyttelse følger ikke med dette produkt, men er
påkrævet iht. standarderne. Se Tabel 4 og 5 for krav til kabelføring. Hvis en aflåselig
udgangsafbryder er påkrævet, skal den anskaffes af brugeren.
Tabel 7. Tilspændingsmomenter for klemmerne på UPS-anlæggets strømkabel
UPS-ramme
Funktion
Tilspændingsmoment Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: batteri +/-
3
PE (jord)
10 Nm for 16-35 mm
2
ledning
6 Nm for 4-10 mm
2
ledning
4 Nm for 2,5 mm
2
ledning
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: batteri +/-
6
PE (jord)
10 Nm for 16-35 mm
2
ledning
6 Nm for 4-10 mm
2
ledning
4 Nm for 2,5 mm
2
ledning
X1
1.6
67
DA
UPS-ramme
Funktion
Tilspændingsmoment Nm
91PS 15 kW
X2, X3
7
X4
3
PE (jord)
10 Nm for 16-35 mm
2
ledning
6 Nm for 4-10 mm
2
ledning
4 Nm for 2,5 mm
2
ledning
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (jord)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Handling
Ja/Nej
Al emballage og fastgøringsmidler er blevet fjernet fra alle kabinetter.
Hvert kabinet i UPS-anlægget er placeret på installationsstedet.
Et jordtilslutningssæt og monteringssæt er installeret mellem kabinetter, som er
sammenboltede.
Alle rør og kabler er ført korrekt til UPS-anlægget og eventuelle andre kabinetter.
Alle strømførende kabler er korrekt dimensionerede og korrekt afsluttede.
Neutrale ledere er installeret og jordet i henhold til kravene.
En jordleder er korrekt installeret.
Batterikablerne er afsluttet og tilsluttet til batteristikkene.
Batterishuntudløsning og AUX-kontaktsignalets kabler er tilsluttet fra UPS-anlægget til
batteriafbryderen.
LAN-stikmoduler er installerede.
Alle LAN-forbindelser er afsluttede.
Aircondition-udstyr er installeret og fungerer korrekt.
Området omkring det installerede UPS-anlæg er rent og støvfrit (det anbefales at UPS-
anlægget installeres på et plant gulv, som er egnet til computer- og elektronisk udstyr).
Der er tilstrækkelig arbejdsplads omkring UPS-anlægget og andre kabinetter.
Der findes passende belysning omkring hele UPS-anlægget og tilhørende udstyr.
En 230 VAC-stikudgang er placeret inden for en afstand på 7,5 meter fra UPS-udstyret.
Fjernbetjent nødslukning (REPO) er monteret på dens installationssted og dens
kabelføring er afsluttet inde i UPS-kabinettet.
Hvis der anvendes EOP i NC-konfigurationen, er der installeret en jumper på EOP
mellem benene 1 og 2.
(EKSTRAUDSTYR) Alarmrelæer og signaludgange har korrekt kabelføring.
(EKSTRAUDSTYR) En ekstern batteriafbryderstyring er monteret på dets
installationssted, og dens kabelføring er afsluttet inde i UPS-anlægget og
batterikabinettet.
(EKSTRAUDSTYR) Tilbehør er monteret på dets installationssteder, og dets kabelføring
er afsluttet inden i UPS-kabinettet.
Idriftsættelse og kontrol af driften skal udføres af en autoriseret tekniker fra Eatons
kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton.
68
DA
Udpakning og aflæsning af UPS-enheden er vist i figur 9.1 - 9.8.
Inden du pakker UPS-anlægget ud og aflæsser det, skal TipNTell/DropNTell-indikatorerne
på pakkens overflade kontrolleres. Hvis udstyret er blevet transporteret korrekt i opret
position, vil indikatorerne være intakte. Hvis TipNTell-indikatorpilen er blevet blå, eller
pilehovederne på DropNTell-indikatoren er sorte, skal de relevante parter kontaktes med
anmeldelse af ukorrekt transport.
Under transporten er UPS-kabinettet boltet fast til en træpalle. Inden kabinettet tages ned
af pallen, flyttes det til installationsstedet ved hjælp af en gaffeltruck eller andet løfteudstyr.
ADVARSEL
UPS-kabinettet er tungt. Hvis udpakningsinstruktionerne ikke overholdes nøje, kan
kabinettet krænge over og forårsage alvorlige skader.
Vip ikke UPS-kabinettet mere end 10 grader i vertikal retning, ellers kan det krænge
over.
BEMÆRK: Enheden skal tage ned fra pallen, så snart transportremmene er fjernet.
Når transportremmene er fjernet og justeringsfødderne trukket op, må der ikke længere
bruges gaffeltruck til at løfte enheden ned fra pallen. Bemærk, at UPS-kabinettet er
tungt, og der er hjul under kabinettet.
Hvis du flytter kabinettet fra dets oprindelige opstillingssted og flytter det til et nyt sted
på en palle, skal justeringsfødderne sænkes indtil kabinettet ikke længere støtter på
hjulene. Transportbeslagene skal fastgøres til kabinettet og pallen.
Operatøren skal levere kabelføringen til tilslutning af UPS-anlægget til den lokale
strømkilde. Installationen af UPS-anlægget skal udføres af en lokal, kvalificeret elektriker.
Inspektion af installationen og den første ibrugtagning af UPS-anlægget samt installation af
et ekstra batterikabinet skal udføres af autoriseret tekniker fra Eatons kundeservice eller af
kvalificeret servicepersonale autoriseret af Eaton.
Installation af UPS-anlægget er vist i figur 10.1-10.5.
UPS-strømkablets klemmer er vist i figur 6.1 (91PS 15 kW-ramme), 6.2 (93PS 20 kW-
ramme), 7.1 (91PS 30 kW-ramme med fælles batteri), 7.2 (91PS 30 kW-ramme med
valgfrit separat batteri), 8.1 (93PS 40 kW-ramme med fælles batteri) og 8.2 (93PS 40 kW-
ramme med valgfrit separat batteri).
X1
Ensretterindgang
X4/-
Eksternt batteri -
X2
Bypassindgang
TB20
Ekstern batteriudløser
X3
UPS-udgang
TB21
Ekstern batteriudløser
X4/+
Eksternt batteri +
PE
Jordingsbeskyttelse
UPM2
(separat batteri)
69
DA
UPS-enhedens kommunikatiosklemmer er vist i figur 5.1 og 5.2. Klemmernes tildeling er
følgende:
1. TB11, ikke anvendt
2. TB10, ikke anvendt
3. TB9, ikke anvendt
4. TB8, ekstern CAN-
afslutning
5. TB8, ekstern CAN
6. TB6, pull chain-bus
7. USB1, USB-vært
(tilslutning til tilbehør)
8. USB2, USB-enhed
(tilslutning til computer)
9. Minislot 1
10. TB1, signalindgang 1-5
11. TB2, ikke anvendt
12. TB3, ikke anvendt
13. Seriel COM-port RS-232
14. Minislot 2
15. TB4, EPO
16. TB5, relæudgang
Hvis kundens eget batterisystem skal installeres, skal systemet installeres som anvist af
batteriets og batterisystemets producent, og alle nationale regler og bestemmelser skal
overholdes.
Oplysninger om batterispecifikationer kan findes i bruger- og installationsvejledningen til
Eaton 91PS/93PS UPS 8-40 kW.
91PS/93PS 8-40 kW UPS-enhederne er altid udstyret med en intern batteriafbryder, som
kun afbryder UPS-enhedens interne batterier (undtagen for C-modellen, hvor den interne
batteriafbryder kan bruges til eksterne batterier). Den eksterne batteriafbryder er en central
del af det eksterne batterikabinet eller stativ, og skal placeres inde i dette. Med ekstern
batteriafbryder er signalkablingen vigtig.
Både interne og eksterne batteriafbrydere kan udløses (afbrydes) ved at tilføre strøm til
deres shuntudløserspole. Shuntudløserspolerne i de eksterne batteriafbrydere er
strømførte (styrede) gennem stikkene TB20 og TB21 (TB21 er kun tilgængelig på 8-40 kW
UPS med separat batterikonfiguration). Standardspændingen for shuntudløserspolen er
24 VDC.
Batteriudløserens ledningsføring er vist i figur 11. Komponenterne er følgende:
A
Ekstern batteriafbryder
3
Ben 3, AUX-kontakt
1
Ben 1, Shuntudløsning spole +
4
Ben 4, AUX-kontakt retur
2
Ben 2,shuntudløsningsspole +
Se bruger- og installationsvejledningen til Eaton 91PS/93PS 8-40 kW UPS og
instruktionsvejledningen, som følger med det eksterne batterikabinet, for instruktioner om
installation af det eksterne batterikabinet og batteriets strømkabler. Det eksterne
batterikabinet/det kundeleverede batterisystem skal jordforbindes til PE-klemme 17.
EPO er tilsluttet EPO-konnektoren på UPS-anlæggets øverste frontpanel. EPO-kontaktens
tilslutninger er vist i figur 12.
Oplysninger om installation af grænsefladetilslutningerne kan findes i bruger- og
installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW.
70
DA
En allround relækontakt leveres som standard på UPS-anlægget. Der findes også en
alarmkontakt. Udgangsrelæernes konfigurationer er vist i figur 13.
Du kan bruge en normalt lukket eller normalt åben kontakt. Hvis kontaktens tilstand skifter
fra den tilstand, du angiver som normal, udstedes et signal. Du kan tilslutte denne kontakt
til udstyr på din enhed (f.eks. en lampe eller en alarmklokke), som giver dig besked, når en
alarm er aktiv på UPS-anlægget.
BEMÆRK: Brug ikke kontakter som overskrider 30 VAC (RMS) og 30 VDC ved 5 A
maksimum.
Oplysninger om parallel ledningsføring af 91PS/93PS UPS-systemer kan findes i bruger-
og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW.
71
RU
1 Безопасность
ОПАСНОСТЬ
Важные сведения по технике безопасности!
Храните эти инструкции в доступном месте!
В данном документе приводятся важные правила техники безопасности и краткие
инструкции по проверке ИБП после поставки, установке и его эксплуатации. Это краткое
руководство может использоваться только в качестве контрольного списка при установке
устройства на объекте.
В целевую аудиторию читателей данного руководства входят опытные специалисты,
планирующие и выполняющие установку ИБП.
ОПАСНОСТЬ
Прежде чем приступить к эксплуатации ИБП, ознакомьтесь с инструкциями,
приведенными в Руководстве по установке и эксплуатации ИБП Eaton 91PS/93PS UPS
8–40 кВт.
Полную версию инструкций можно загрузить с сайта www.eaton.com/91psand93ps.
К проведению работ внутри ИБП допускается только сервисный инженер службы
клиентской поддержки Eaton или квалифицированные специалисты, уполномоченные
компанией Eaton. В этом ИБП нет деталей, обслуживаемых пользователем.
ИБП работает от сети питания, аккумулятора или линии байпаса. В нем содержатся
компоненты, в которых присутствуют высокие токи и напряжения. Правильно
установленный корпус должен быть заземлен и иметь степень защиты IP20 от поражения
электрическим током и попадания посторонних предметов. Помните, что ИБП является
сложной силовой системой и к его эксплуатации и обслуживанию допускается только
квалифицированный персонал.
ОПАСНОСТЬ
В данном ИБП присутствует опасное для жизни напряжение.
Аккумуляторы могут стать причиной поражения электрическим током или ожогов
вследствие КЗ, вызванного большими токами. Соблюдайте меры предосторожности.
Аккумуляторы могут быть под ВЫСОКИМ НАПРЯЖЕНИЕМ, а также содержать
КОРРОЗИЙНЫЕ, ТОКСИЧНЫЕ и ВЗРЫВООПАСНЫЕ вещества. Ввиду наличия
аккумуляторного блока помните, что на выходной розетке также может присутствовать
высокое напряжение даже при условии, что к ИБП не подключен источник питания
переменного тока. Инструкции по выключению приводятся в Руководстве по установке и
эксплуатации.
ПРЕДУПРЕЖДЕНИЕ
Для питания ИБП используются собственные источники энергии (аккумуляторы). На
выходных клеммах может присутствовать напряжение даже после отключения ИБП от
источника питания переменного тока. Для уменьшения опасности возгорания или
поражения электрическим током следует устанавливать данный ИБП в помещении с
контролируемой температурой и влажностью, и отсутствием посторонних примесей,
способных проводить электрический ток.
Не устанавливайте шкаф ИБП модели 91PS/93PS C на другой схожий шкаф или шкафы.
Не ставьте никаких посторонних предметов на шкаф ИБП 91PS/93PS. При установке
шкафа ИБП модели 91PS/93PS C на полку используйте соответствующие опоры,
предотвращающие опрокидывание или падение ИБП.
72
RU
ПРЕДУПРЕЖДЕНИЕ
Температура воздуха не должна превышать 40°C (104°F). Не устанавливайте ИБП
вблизи от воды или в местах с повышенной влажностью (максимум 95%). Система не
предназначена для эксплуатации вне помещений.
Перед началом операций установки или обслуживания убедитесь, что отключены
источники питания с переменным и постоянным током. Электропитание может поступать
из нескольких источников. Также обеспечьте неразрывность рабочего/защитного
заземления.
На выходных клеммах параллельной системы может присутствовать напряжение даже
после выключения ИБП.
Опасность поражения электрическим током. Во избежание получения травм,
запрещается вносить изменения в схему подключения или соединения аккумуляторов.
ВАЖНО: Перед установкой убедитесь, что отключены все аккумуляторные блоки.
ВНИМАНИЕ
К установке и обслуживанию устройства допускаются только квалифицированный
технический персонал, обладающий необходимыми знаниями по аккумуляторам и
технике безопасности. Установка и обслуживание АКБ производится под напряжением и
требует использования электроизоляционного инструмента. Необходимо ограничить
доступ посторонних лиц к аккумуляторам.
Перед установкой или заменой аккумуляторов необходимо прочитать все
предупреждения, предостережения и примечания по технике безопасности.
Запрещается отключать аккумуляторы во время работы ИБП от аккумулятора.
Количество и тип заменяемых аккумуляторов должны совпадать с оригинальными
аккумуляторами, установленными в ИБП. См. более подробную информацию в
руководстве по эксплуатации ИБП.
Перед подключением или отключением клемм АКБ отключите его от источника питания,
разомкнув соответствующий прерыватель цепи.
Проверьте аккумулятор на предмет непреднамеренного заземления. При обнаружении
такого заземления устраните его. Контакт с любой частью заземленного аккумулятора
может привести к поражению электрическим током.
Утилизация аккумуляторов выполняется в соответствии с требованиями местного
законодательства в отношении утилизации.
Запрещается сжигать аккумуляторы. Под воздействием пламени возможен взрыв
аккумуляторов.
Для уменьшения опасности возгорания подключайтесь только к цепи, оснащенной
входным выключателем с максимальным номинальным входным током в соответствии с
национальными и местными правилами установки.
Для обеспечения надлежащего охлаждения системы и защиты персонала от опасного
напряжения, присутствующего в устройстве, следует держать дверцу ИБП закрытой и
установить передние панели.
Запрещается установка или эксплуатация системы ИБП вблизи газовых или
электрических источников тепла.
Условия эксплуатации должны соответствовать требованиям, приведенным в
настоящем документе. В помещении с ИБП следует поддерживать чистоту, избегать
высокой влажности и нагромождения посторонних предметов.
Соблюдайте требования, указанные на табличках с надписями ОПАСНОСТЬ,
ВНИМАНИЕ и ПРЕДУПРЕЖДЕНИЕ, расположенных на внешней и внутренней
поверхностях оборудования.
73
RU
2 Установка ИБП Eaton 91PS/93PS
2.1 Введение в ИБП Eaton 91PS/93PS
Источник бесперебойного питания (ИБП) Eaton® 91PS/93PS представляет собой
оперативную систему: непрерывного действия, бестрансформаторная, двухдиапазонная,
полупроводниковая, однофазная (91PS) или трехфазная (93PS). ИБП служит для
непрерывной подачи гармонизированного переменного тока к критической нагрузке и
защищает ее от отказов системы электроснабжения. Значение номинальной выходной
мощности Eaton 91PS/93PS рассчитано с учетом модулей бесперебойного питания (UPM)
с номиналом 15 или 20 кВт.
Устройство 91PS/93PS также выпускается в модификации «C», которая состоит из
электрической части рамы ИБП 91PS/93PS на 15/20 кВт без отсека для аккумуляторов.
Таблица 1. Номинальные ВАХ шкафа ИБП
Рама ИБП
Рис.
(Иллюстрация 1)
Количество ИБП
Номинальные ВАХ
91PS 15 кВт
A и B
1
8, 10, 15 кВт
91PS 30 кВт
C
1 или 2
8, 10, 15, 20, 30 кВт
93PS 20 кВт
A и B
1
8, 10, 15 или 20 кВт
93PS 40 кВт
C
1 или 2
8, 10, 15, 20, 30 или 40
кВт
Основные компоненты ИБП 91PS/93PS UPS 8-40 кВт показаны на рисунке 2. Устройство
состоит из следующих основных компонентов:
1. Панель управления
2. Дверной замок
3. Модуль питания (UPM)
4. Внутренний аккумулятор (не в
моделях «C»)
5. Зона средств связи
6. Входной переключатель
7. Выключатель аккумулятора
8. Переключатель сервисного байпаса
(дополнительно)
.
ОПАСНОСТЬ
В данном ИБП присутствует опасное для жизни напряжение.
К проведению работ внутри ИБП допускается только сервисный инженер службы
клиентской поддержки Eaton или квалифицированные специалисты, уполномоченные
компанией Eaton. В этом ИБП нет деталей, обслуживаемых пользователем.
Полный текст инструкций по технике безопасности приводится в инструкциях по
установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
2.1
Окружающая среда
Установка ИБП выполняется в соответствии с рекомендациями, приведенными в
инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
2.2
План распаковки и установки ИБП
Для установки ИБП выполните следующую последовательность шагов:
74
RU
1. Составьте план установки системы ИБП.
2. Подготовьте объект к установке системы ИБП.
3. Осмотрите и распакуйте шкаф ИБП.
4. Выгрузите и установите шкаф ИБП и подключите проводку системы.
5. Заполните контрольный список по установке.
6. Вызовите квалифицированных специалистов для проведения предварительной
регламентной проверки и ввода в эксплуатацию.
ПРИМЕЧАНИЕ: Запуск и регламентные проверки должны выполняться
квалифицированным специалистом сервисного центра Eaton или квалифицированными
специалистами, уполномоченными компанией Eaton, в противном случае будут
аннулированы гарантийные обязательства.
2.2.1 Создание плана установки
Перед установкой системы ИБП внимательно прочитайте приведенные инструкции по
установке соответствующей системы. Создайте логичный план установки системы
согласно инструкциям и рисункам.
2.2.2 Подготовка объекта
Для обеспечения максимальной производительности системы ИБП окружающая среда в
месте установки устройства должна соответствовать параметрам, приведенным в
инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
2.2.2.1 Рекомендации по условиям окружающей среды и установке
Условия установки должны соответствовать требованиям веса и размеров ИБП,
указанным в Таблицах 2 и 3.
Размеры шкафа ИБП показаны на рисунке 1. Помните, что глубина установки (750 мм)
учитывает размер кабельных уплотнений.
Таблица 2. Массы шкафов ИБП с картонной упаковкой
Модель C, 820 кВт
(Иллюстрация 1,
рис. А)
Рама на 15/20 кВт*
(Иллюстрация 1,
рис. В)
Рама на 30/40 кВт*
(Иллюстрация 1,
рис С)
Транспортный вес
98 кг
293 кг
558 кг
Вес установленного
оборудования
86 кг
280 кг
532 кг
Нагрузка на пол
310 кг/м
2
1 107 кг/м
2
1 478 кг/м
2
* В комплект всех моделей входит максимальное количество встроенных аккумуляторов.
Для регулировки температуры внутренних компонентов в шкафах ИБП используется
принудительное воздушное охлаждение. По умолчанию, воздухоприемники расположены
в передней части шкафа, а воздуховыпускные отверстия в задней, см. рисунок 3. Для
обеспечения правильной циркуляции воздуха впереди и сзади каждого шкафа
необходимо оставлять достаточно свободного пространства. Убедитесь, что температура
входящего в ИБП охлаждающего воздуха не превышает +40 °C. Требования к вентиляции
приводятся в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
75
RU
Таблица 3. Минимальное свободное пространство вокруг шкафа ИБП
Рама на 15/20 кВт
(Иллюстрация 1,
рис. А и В)
Рама на 30/40 кВт
(Иллюстрация 1,
рис. С)
Свободное пространство
сверху
500 мм
500 мм
Свободное пространство
спереди
500 мм
650 мм
Свободное пространство
сзади
150 мм
250 мм
Свободное пространство
сбоку
0 мм
0 мм
На рисунках 4.1 и 4.2 показана рекомендуемая рабочая температура окружающего
воздуха и влажность для работы системы ИБП. Для обеспечения длительного срока
службы аккумуляторов VRLA рекомендуется поддерживать температуру окружающей
среды в диапазоне от +20 °C до +25 °C.
2.2.2.2 Подготовка силовой проводки системы ИБП
Таблица 4. Минимальные рекомендуемые сечения многожильных кабелей и размеры
предохранителей для выпрямительных и байпасных входов и выходных кабелей
ИБП (3-фазный вход, 3-фазный выход)
Номинальные ВАХ (кВт)
ИБП 93PS
8
10
15
20
30
40
Кабель [мм
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Предохранитель
выпрямителя [A]
20
20
32
40
63
80
Предохранитель байпаса [A]
20
20
32
40
63
80
Кабель заземления [мм
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Максимальное
поперечное сечение
проводника
Рама 20 кВт и 20 кВт модели «C»: одножильный провод 16
мм
2
, многожильный провод с изоляционной трубкой: 10 мм
2
Рама 40 кВт: одножильный провод 70 мм
2
, многожильный
провод с изоляционной трубкой: 50 мм
2
Таблица 5. Минимальные рекомендуемые сечения многожильных кабелей и размеры
предохранителей для выпрямительных и байпасных входов и выходных кабелей
ИБП (3-фазный вход, 1-фазный выход)
Номинальные ВАХ (кВт)
ИБП 91PS
8
10
15
20
30
Кабель выпрямителя [мм
2
]
2,5
4
10
10
16
Предохранитель
выпрямителя [A]
20
20
32
40
63
76
RU
Номинальные ВАХ (кВт)
ИБП 91PS
8
10
15
20
30
Байпас, внешний кабель [мм
2
]
10
16
25
35
70
Предохранитель байпаса [A]
50
63
80
100
160
Кабель заземления [мм
2
]
10
16
16
16
35
Максимальное
поперечное сечение
проводника, рама на 15
кВт и модель С на 15 кВт
Выпрямитель: одножильный провод 16 мм
2
,
многожильный провод с изоляционной трубкой: 10 мм
2
Байпас/выход: одножильный провод 70 мм
2
,
многожильный провод с изоляционной трубкой: 50 мм
2
Максимальное
поперечное сечение
проводника, рама на 30
кВт
Выпрямитель: одножильный провод 70 мм
2
,
многожильный провод с изоляционной трубкой: 50 мм
2
Байпас/выход: одножильный провод 95 мм
2
,
многожильный провод с изоляционной трубкой: 95 мм
2
ВНИМАНИЕ
Убедитесь, что предполагаемый ток КЗ на входных клеммах ИБП не будет превышать
значение условного тока КЗ, указанного на паспортной табличке ИБП.
Таблица.6 Минимальные рекомендуемые сечения кабелей и размеры предохранителей для
внешнего аккумуляторного блока
Номинал ИБП (кВт)
8
10
15
20
30
40
Положительная и
отрицательная линия [мм
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Предохранитель
аккумулятора [A]
63
63
63
63
160
160
Кабель заземления [мм
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Максимальное
поперечное сечение
проводника
Рама 15/20 кВт, модель «C» и рама на 30/40 кВт с отдельным
аккумулятором: одножильный провод: 25 мм
2
, многожильный
провод с изоляционной трубкой: 16 мм
2
Рама на 30/40 кВт с общим аккумулятором: одножильный
провод: 90 мм
2
, многожильный провод с изоляционной трубкой:
70 мм
2
Информация о номинальном и максимальном токе при номинальной мощности и
напряжении приводится в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS
8–40 кВт.
При использовании дополнительного внешнего аккумулятора для обоих аккумуляторных
блоков (шкафов) предусмотрены отдельные клеммы.
2.3.1
ПРИМЕЧАНИЕ: Внешняя защита от сверхтоков не входит в комплект поставки
данного изделия, но требуется согласно правилам установки электрического
оборудования. Информации по требованиям к проводке приведена в Таблицах 4 и 5.
Если требуется блокируемое устройство отключения выхода, его должен
предоставить клиент.
77
RU
Таблица 7. Моменты затяжки на клеммной колодке кабеля питания ИБП
Рама ИБП
Функция
Момент затяжки Нм
93PS 20 кВт
X1, X2, X3: L1, L2, L3, N
1.6
X4: аккумулятор +/-
3
PE (заземление)
10 Нм для провода 1635 мм
2
6 Нм для провода 410 мм
2
4 Нм для провода 2,5 мм
2
93PS 40 кВт
X1, X2, X3: L1, L2, L3, N
6
X4: аккумулятор +/-
6
PE (заземление)
10 Нм для провода 1635 мм
2
6 Нм для провода 410 мм
2
4 Нм для провода 2,5 мм
2
91PS 15 кВт
X1
1.6
X2, X3
7
X4
3
PE (заземление)
10 Нм для провода 1635 мм
2
6 Нм для провода 410 мм
2
4 Нм для провода 2,5 мм
2
91PS 30 кВт
X1
6
X2, X3
17
X4
6
PE (заземление)
7 Нм (X1, X2, X3)
3.5 Нм (X4)
2.2.3 Проверочный список по монтажу
Действие
Да/нет
Со шкафов снята вся упаковка и ограничители.
Каждый шкаф системы ИБП размещен в месте установки.
Зажимы заземления/крепежные элементы установлены между соединенными
вместе шкафами.
Вся проводка и кабели правильным образом подведены к ИБП и любым
дополнительным шкафам.
Все силовые кабели имеют правильный размер и правильным образом заделаны.
Контакты нейтрали установлены или соединены с заземлением согласно
требованиям.
Заземление установлено правильным образом.
Кабели аккумуляторов подведены и подключены к разъемам для аккумуляторов.
Сигнальная проводка независимого выключателя и дополнительных контактов
подключена от ИБП к прерывателю аккумулятора.
Установлены отводы для линии LAN.
Выполнена все соединения линии LAN.
Системы кондиционирования воздуха установлены и работают правильным
образом.
78
RU
Действие
Да/нет
Пространство вокруг установленной системы ИБП должно быть чистым и
незапыленным (рекомендуется устанавливать ИБП на ровной поверхности,
пригодной для установки компьютерного или электронного оборудования).
Вокруг ИБП и других шкафов имеется достаточное рабочее пространство.
В месте установки оборудования ИБП обеспечено достаточное освещение.
На расстоянии не более 7,5 метров от оборудования ИБП имеется розетка 230 В
переменного тока.
Модуль удаленного аварийного отключения электропитания (REPO) установлен в
требуемом месте, и его проводка подведена к клеммам внутри шкафа ИБП.
При использовании в конфигурации НЗ выключателя EPO на него устанавливается
перемычка между контактами 1 и 2.
(ДОПОЛНИТЕЛЬНО) Аварийные реле и выводы сигнала подключены надлежащим
образом.
(ДОПОЛНИТЕЛЬНО) Модуль удаленного отключения аккумуляторов установлен в
требуемом месте, и его проводка подведена к клеммам внутри ИБП и
аккумуляторного шкафа.
(ДОПОЛНИТЕЛЬНО) Дополнительное оборудование установлено в требуемых
местах, и его проводка подведена к клеммам внутри шкафа ИБП.
Запуск и эксплуатационная проверка выполнены сервисным инженером службы
клиентской поддержки Eaton или квалифицированными специалистами,
уполномоченными Eaton.
2.2.4 Распаковка и выгрузка ИБП
На рисунках 9.19.8 показана процедура распаковки и выгрузки ИБП.
Перед началом распаковки и выгрузки ИБП проверьте индикаторы TipNTell/DropNTell на
поверхности упаковки. Если оборудование транспортировалось надлежащим образом в
вертикальном положении, то индикаторы останутся в исходном состоянии. Если стрелка
индикатора TipNTell полностью заполнилась синим цветом или головки стрелок
индикатора DropNTell почернели, то свяжитесь с соответствующими сторонами и заявите
о нарушениях при транспортировке.
Для удобства транспортировки шкаф ИБП крепится болтами к деревянному поддону.
Перед снятием шкафа с поддона перевезите его на место установки с помощью
вилочного погрузчика или другой погрузочной техники.
ПРЕДУПРЕЖДЕНИЕ
Шкаф ИБП обладает большим весом. В случае нарушения инструкций по распаковке
шкаф может опрокинуться, что может привести к серьезным травмам.
Не наклоняйте шкаф ИБП более чем на 10 градусов от вертикального положения, чтобы
он не опрокинулся.
ПРИМЕЧАНИЕ: После снятия транспортировочных скоб немедленно уберите
устройство с поддона.
После снятия транспортировочных скоб и втягивания регулировочных ножек
запрещается использовать вилочный погрузчик для транспортировки находящегося
на поддоне устройства. Помните, что шкаф ИБП обладает большим весом, а в его
нижней части имеются ролики.
Для перемещения шкафа из места исходной установки на поддоне опустите
регулировочные ножки так, чтобы шкаф перестал опираться на ролики.
79
RU
2.3
Установка системы ИБП
Проводку для подключения ИБП к местному источнику питания должен предоставить
оператор. Установка ИБП выполняется местным квалифицированным специалистом по
электрооборудованию. К проверке установки и первому запуску ИБП, а также к установке
дополнительного аккумуляторного шкафа допускаются только квалифицированные
сервисные специалисты, уполномоченные Eaton ил уполномоченные сотрудники
технической службы клиента.
2.3.1 Порядок установки ИБП
На рисунках 10.110.5 показана процедура распаковки и выгрузки ИБП.
Клеммы силового кабеля ИБП показаны на рисунках 6.1 (91PS, рама на 15 кВт), 6.2 (93PS,
рама на 20 кВт), 7.1 (91PS, рама на 30 кВт с общей батареей), 7.2 (91PS, рама на 30 кВт с
опциональной отдельной батареей), 8.1 (93PS, рама на 40 кВт с общей батареей) и 8.2
(93PS, рама на 40 кВт с опциональной отдельной батареей).
X1
Вход выпрямителя
X4/-
Внешний аккумулятор -
X2
Вход байпаса
TB20
Автоматический
выключатель внешнего
аккумулятора
X3
Значение тока на выходе из
ИБП
TB21
Автоматический
выключатель внешнего
аккумулятора
X4/+
Внешний аккумулятор +
PE
Защитное заземление
UPM2
(отдельный аккумулятор)
Клеммы для связи ИБП показаны на рисунке 5.1 и 5.2. Кабель имеет следующие клеммы:
1. TB11, не используется
2. TB10, не используется
3. TB9, не используется
4. TB8, клемма для
внешнего подключения
CAN
5. TB7, внешняя сеть CAN
6. TB6, шина
параллельного
монтажа
7. USB1, USB-хост (при
подключении к
дополнительному
оборудованию)
8. USB2, USB-устройство
(при подключении к
компьютеру)
9. MiniSlot 1
10. TB1, сигнальный вход 15
11. TB2, не используется
12. TB3, не используется
13. Последовательный COM-
порт RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, релейный выход
2.3.2 Установка аккумуляторной системы
При установке аккумуляторной системы, предоставленной клиентом, следует
руководствоваться инструкциями к самой системе и прочими инструкциями
производителя, а также применимыми национальными требованиями и нормативами.
Технические характеристики аккумулятора приводятся в инструкциях по установке и
эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
2.3.3 Проводка расцепителя аккумулятора
Устройства ИБП 91PS/93PS 840 кВт стандартно оборудованы встроенным
выключателем аккумулятора, который предназначен только для выключения встроенных
аккумуляторов ИБПа исключением модели «С», в которой встроенный выключатель
может использоваться для выключения внешних аккумуляторов). Внешний выключатель
аккумуляторов является важнейшим компонентом внешнего аккумуляторного шкафа или
стойки, поэтому подлежит обязательной установке. При наличии внешнего выключателя
аккумулятора очень важно обеспечить надлежащую систему сигнальных кабелей.
При подаче питания на катушку шунтового расцепителя могут сработать (выключиться)
как встроенные, так и внешние выключатели аккумуляторов. Питание (управляемое)
катушек шунтовых расцепителей внешних выключателей аккумуляторов осуществляется
80
RU
через разъемы TB20 и TB21 (TB21 имеется только в ИБП 840 кВт в конфигурации с
отдельным аккумулятором). Напряжение по умолчанию на катушке шунтового
расцепителя составляет 24 впост. тока.
На рисунке 11 показана схема проводки расцепителя аккумулятора. Устройство состоит
из следующих компонентов:
A
Внешний выключатель
аккумулятора
3
Вывод 3, вспомогательный
контакт
1
Вывод 1, катушка шунтового
расцепителя +
4
Вывод 4, возвратный
вспомогательный контакт
2
Вывод 2, катушка шунтового
расцепителя -
2.3.4 Установка внешнего аккумуляторного шкафа ИБП и подключение
силовой проводки аккумулятора
Инструкции по установке внешнего аккумуляторного шкафа и силовой проводки
аккумулятора приводятся в инструкциях по установке и эксплуатации ИБП Eaton
91PS/93PS 840 кВт и в руководстве по эксплуатации внешнего аккумуляторного шкафа.
Выполните заземление внешнего аккумуляторного шкафа/собственной системы
аккумуляторов на клемму защитного заземления 17.
2.3.5 Установка удаленного выключателя EPO
Выключатель EPO подключается к разъему EPO на верхней передней панели устройств
ИБП. Соединения для выключателя EPO показаны на рисунке 12.
2.3.6 Установка соединений интерфейса
Информация по установке подключений интерфейса приводится в инструкциях по
установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
2.3.7 Универсальные релейные контакты
В стандартный комплект поставки ИБП входит один универсальный релейный контакт.
Также имеется аварийный контакт. Конфигурации выходных реле показаны на рисунке 13.
Вы можете использовать нормальноамкнутый или нормально-разомкнутый контакт.
Сигнал поступает тогда, когда состояние контакта изменяется с того состояния, которое
вы определили, какнормальное. Вы можете подключить этот контакт к оборудованию на
вашем объекте (например, к световой или звуковой сигнализации), которое будет
информировать вас об аварийном сигнале на ИБП.
ПРИМЕЧАНИЕ: Не допускайте работы контактов с током, превышающим 30 В
переменного тока (RMS) и 30 В постоянного тока при 5 А.
2.3.8 Проводка в параллельных системах ИБП 91PS/93PS
Информация по проводке в параллельных системах ИБП 91PS/93PS приводится в
инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 840 кВт.
81
NL
1
GEVAAR
Belangrijke veiligheidsinstructies!
Bewaar deze instructies!
Dit document verschaft belangrijke veiligheidsinstructies en een korte instructie voor het
controleren van de opbrengst van de UPS en het installeren van de UPS. Deze verkorte
handleiding is uitsluitend bedoeld voor gebruik als installatiechecklist ter plaatse.
De beoogde doelgroep van dit document bestaat uit ervaren vakmensen die de installatie
van de UPS plannen en uitvoeren.
GEVAAR
Lees voordat u met de UPS aan het werk gaat de volledige installatie-instructies zoals
verschaft in de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding.
De volledige instructies zijn beschikbaar voor downloaden via
www.eaton.com/91psand93ps.
Werkzaamheden aan de binnenzijde van de UPS moeten door een erkende Eaton
klantenservicemonteur of door Eaton erkende gekwalificeerde servicemedewerkers
worden uitgevoerd. De UPS bevat geen door de gebruiker te onderhouden onderdelen.
De UPS werkt met netspanning, accuspanning of bypass-spanning. De UPS bevat
componenten die hoge stroom en spanning voeren. Een goed geïnstalleerde behuizing is
geaard en heeft een IP20-classificatie tegen elektrische schokken en vreemde
voorwerpen. De UPS is echter een geavanceerd voedingssysteem en alleen
gekwalificeerde medewerkers mogen de UPS installeren en servicewerkzaamheden
hieraan uitvoeren.
GEVAAR
Deze UPS bevat dodelijke spanningen.
Accu's kunnen door een hoge kortsluitstroom elektrische schokken of brandwonden
veroorzaken. Tref de voorzorgsmaatregelen.
Accu's kunnen HOGE SPANNINGEN en CORROSIEVE, GIFTIGE en EXPLOSIEVE
stoffen bevatten. In verband met de accustreng kunnen de uitgangen onder
hoogspanning staan, zelfs als de AC-voeding niet op de UPS is aangesloten. Lees de
uitschakelinstructies in de Gebruikers- en Installatiehandleiding.
WAARSCHUWING
De UPS wordt door een eigen energiebron gevoed (accu's). De
uitgangsaansluitklemmen kunnen onder spanning staan, zelfs als de UPS van een
wisselstroomvoedingsbron is afgekoppeld. Installeer om het risico op brand of elektrische
schokken te verlagen deze UPS binnenshuis in een omgeving waar temperatuur en
vochtigheid worden geregeld en waar geen geleidende verontreinigde stoffen aanwezig
zijn.
Stapel de 91PS/93PS C-model UPS-kast niet op andere vergelijkbare kasten. Stapel
niets op de 91PS/93PS UPS-kast. Gebruik bij installatie van de 91PS/93PS C-model
UPS-kast op een plank de benodigde steunen om kantelen of vallen van de UPS te
voorkomen.
82
NL
WAARSCHUWING
De omgevingstemperatuur mag niet hoger zijn dan 40 °C. Werk niet met de UPS in de
buurt van water of bij een zeer hoge vochtigheid (maximaal 95%). Het systeem is niet
bestemd voor gebruik buitenshuis.
Controleer voordat u enige installatie- of onderhoudswerkzaamheden gaat uitvoeren of
alle AC- en DC-voedingsbronnen zijn afgekoppeld. Voeding kan van meerdere bronnen
afkomstig zijn. Zorg ook voor systeemaarding/PE-continuïteit van het systeem.
In een parallel systeem kunnen uitgangsaansluitklemmen onder spanning staan, zelfs als
de UPS is uitgeschakeld.
Gevaar in verband met elektriciteit. Probeer om letsel te voorkomen niet de bedrading
van de accu's of connectors te wijzigen.
BELANGRIJK: Zorg dat voorafgaande aan de installatie alle accustrengen zijn
afgekoppeld.
PAS OP
Uitsluitend hiervoor gekwalificeerde servicemedewerkers met kennis van accu's en de
vereiste voorzorgsmaatregelen mogen installatie- of servicewerkzaamheden aan accu's
uitvoeren. De werkzaamheden met betrekking tot het plaatsen en onderhouden van
accu's worden uitgevoerd met spanningvoerende verbindingen en vereist gebruik van
geïsoleerde gereedschappen. Houd onbevoegde medewerkers uit de buurt van de
accu's.
Neem voordat u accu's gaat installeren of vervangen alle aanwijzingen aangeduid met
'waarschuwing' en 'voorzichtig' alsook opmerkingen betreffende de juiste werkwijze in
acht. Koppel de accu's niet af als de UPS in de accumodus staat.
Zorg dat de vervangende accu's hetzelfde nummer en type hebben als de oorspronkelijk
in de UPS geplaatste accu's. Meer nauwkeurige instructies vindt u op de UPS.
Koppel voordat u accuklemmen gaat aansluiten of afkoppelen de voedingsbron af door
de bijbehorende accubeveiliging te openen.
Controleer of de accu niet onbedoeld is geaard. Verwijder als dit het geval is de
aardingsbron. Bij aanraking van een willekeurig deel van een geaarde accu kunt u een
elektrische schok krijgen.
Voer de accu's volgens de lokale eisen af.
Werp accu's niet in open vuur. Bij blootstelling aan vuur kunnen accu's exploderen.
Sluit om het risico van brand te verlagen uitsluitend aan op een met ingangsbeveiligingen
met maximumstroomwaarden uitgerust circuit volgens de nationale en plaatselijke
installatievoorschriften.
Houd om correcte luchtstroming voor koeling te verzekeren en medewerkers tegen
gevaarlijke spanningen in de unit te beschermen de deur van de UPS gesloten en de
voorpanelen geplaatst.
Installeer of gebruik het UPS-systeem niet in de buurt van op gas of elektriciteit werkende
warmtebronnen.
Houd de bedrijfsomgeving binnen de in dit document genoemde parameters. Houd de
omgeving van de UPS ordelijk, schoon en vrij van overmatig vocht.
Neem alle aan de binnen- en buitenzijde van de apparatuur aangebrachte aanwijzingen
met de aanduidingen GEVAAR, VOORZICHTIG en WAARSCHUWING in acht.
83
NL
2
De Eaton® 91PS/93PS uninterruptible power supply (UPS) is een werkelijk online,
ononderbroken en geïntegreerd eenfase- (91PS) of driefasesysteem (93PS). Het levert
geconditioneerde en ononderbroken wisselstroom aan een kritische last en beschermt
deze tegen stroomuitval. Het uitgangsvermogen van de Eaton 91PS/93PS is gebaseerd op
ononderbroken voedingsmodules (UPM's = uninterruptible power modules) van 15 kW of
20 kW.
De 91PS/93PS is ook verkrijgbaar als C-model, bestaande uit het elektrische deel van het
91PS/93PS UPS 15/20 kW frame zonder accucompartiment.
Tabel 1. Waarden UPS-kast
UPS-frame
Foto
(Afbeelding 1)
Aantal UPM's
Waarden
91PS 15 kW
A en B
1
8, 10, 15 kW
91PS 30 kW
C
1 of 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A en B
1
8, 10, 15 of 20 kW
93PS 40 kW
C
1 of 2
8, 10, 15, 20, 30 of 40
kW
De belangrijkste onderdelen van de 91PS/93PS UPS 8-40 kW worden in afbeelding 2
weergegeven. De belangrijkste onderdelen zijn de volgende:
1. Bedieningspaneel
2. Deurgrendel
3. Voedingsmodule (UPM)
4. Interne accu (niet in C-modellen)
5. Communicatiecompartiment
6. Ingangsschakelaar
7. Accubeveiliging
8. Bypass-schakelaar voor onderhoud
(optioneel)
.
GEVAAR
Deze UPS bevat dodelijke spanningen.
Werkzaamheden aan de binnenzijde van de UPS moeten door een erkende Eaton
klantenservicemonteur of door Eaton erkende gekwalificeerde servicemedewerkers
worden uitgevoerd. De UPS bevat geen door de gebruiker te onderhouden onderdelen.
Zie voor de volledige veiligheidsinstructies de Eaton 91PS/93PS UPS 8-40 kW
Gebruikers- en Installatiehandleiding.
Installeer de UPS volgens de aanbevelingen in de Eaton 91PS/93PS UPS 8-40 kW
Gebruikers- en Installatiehandleiding.
Voer de volgende basisstappen voor installatie van de UPS in de gegeven volgorde uit:
84
NL
1. Stel een installatieplan voor het UPS-systeem op.
2. Bereid de locatie op het UPS-systeem voor.
3. Pak de UPS-kast uit en controleer deze.
4. Laad de UPS-kast uit en installeer deze en bedraad het systeem.
5. Vul de installatiechecklist in.
6. Laat erkende servicemedewerkers de voorbereidende operationele controles en de
opstart uitvoeren.
OPMERKING: Opstarten en operationele controles moeten worden uitgevoerd door een
erkende Eaton Klantenservicetechnicus of door Eaton erkende gekwalificeerde
servicemedewerkers, anders komen de garantievoorwaarden zoals in de Garantie
beschreven te vervallen.
Lees voordat u het UPS-systeem gaat installeren de instructies en zorg dat u begrijpt hoe
deze instructies van toepassing zijn op het door u te installeren systeem. Volg de
verschafte procedures en afbeeldingen voor het opstellen van een logisch plan voor de
installatie van het systeem.
Voor werking van het UPS-systeem bij piekefficiëntie moet de installatielocatie aan de in
de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding vermelde
omgevingsparameters voldoen.
De installatieomgeving moet aan de eisen betreffende het gewicht en de omvang van de
UPS zoals gegeven in tabellen 2 en 3 voldoen.
De afmetingen van de UPS-kast worden in afbeelding 1 weergegeven. Merk op dat de
dieptemaat (750 mm) inclusief kabelwartels is.
Tabel 2. Gewicht van UPS-kast met kartonnen verpakking
C-model 8-20 kW
(Afbeelding 1,
foto A)
15/20 kW frame*
(Afbeelding 1, foto
B)
30/40 kW frame*
(afbeelding 1, foto C)
Transportgewicht
98 kg
293 kg
558 kg
Geïnstalleerd gewicht
86 kg
280 kg
532 kg
Vloerbelasting
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Merk op dat het maximumaantal interne accu’s bij alle modellen is inbegrepen.
De UPS-kasten regelen de temperatuur van de interne componenten via geforceerde
luchtkoeling. De kast bevat standaard luchtinlaten aan de voorzijde en uitlaten aan de
achterzijde, zie afbeelding 3. Laat voor voldoende luchtcirculatie voor en achter iedere kast
ruimte vrij. Zorg dat de koellucht die de UPS binnenkomt niet warmer is dan +40 °C. Zie
voor ventilatie-eisen de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en
Installatiehandleiding.
85
NL
Tabel 3. Minimale vrije ruimte voor UPS-kast
15/20 kW frame
(Afbeelding 1,
foto’s A en B)
30/40 kW frame
(Afbeelding 1,
foto C)
Vanaf de bovenzijde van de
kast
500 mm
500 mm
Vanaf de voorzijde van de kast
500 mm
650 mm
Vanaf de achterzijde van de
kast
150 mm
250 mm
Vanaf de zijkant van de kast
0 mm
0 mm
De aanbevolen omgevingstemperatuur voor bedrijf en vochtigheid voor het UPS-systeem
wordt weergegeven in afbeeldingen 4.1 en 4.2. Een omgevingstemperatuur tussen +20 °C
en +25 °C wordt aanbevolen voor een lange levensduur van de VRLA-accu's.
Tabel 4. Minimaal aanbevolen maten voor de meeraderige kabel en de zekeringen voor de
gelijkrichter, de bypassingangskabel en de UPS-uitgangskabel (driefase-ingang, driefase-
uitgang)
UPS-vermogen 93PS (kW)
8
10
15
20
30
40
Kabel [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Zekering gelijkrichter [A]
20
20
32
40
63
80
Zekering bypass [A]
20
20
32
40
63
80
PE-kabel [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maximumdoorsnede
geleider
20 kW frame en 20 kW C-model: massieve draad 16 mm
2
,
draadstrengen met bus: 10 mm
2
40 kW frame: massieve draad 70 mm
2
, draadstrengen met bus: 50
mm
2
Tabel 5. Minimaal aanbevolen maten voor de meeraderige kabel en de zekeringen voor de
gelijkrichter, de bypassingangskabel en de UPS-uitgangskabel (driefase-ingang, eenfase-
uitgang)
UPS-vermogen 91PS (kW)
8
10
15
20
30
Gelijkrichterkabel [mm
2
]*
2,5
4
10
10
16
Zekering gelijkrichter [A]
20
20
32
40
63
Bypass, uitgangskabel
[mm
2
]
10
16
25
35
70
Zekering bypass [A]
50
63
80
100
160
PE-kabel [mm
2
]
10
16
16
16
35
86
NL
UPS-vermogen 91PS (kW)
8
10
15
20
30
Maximale doorsnede van
de geleider, 15 kW frame
en 15 kW C-model
Gelijkrichter: massieve draad 16 mm
2
, draadstrengen
met bus: 10 mm
2
Bypass/uitgang: massieve draad 70 mm
2
,
draadstrengen met bus: 50 mm
2
Maximumdoorsnede
geleider, 30 kW frame
Gelijkrichter: massieve draad 70 mm
2
, draadstrengen
met bus: 50 mm
2
Bypass/uitgang: massieve draad 95 mm
2
,
draadstrengen met bus: 95 mm
2
PAS OP
Zorg dat de verwachte kortsluitstroom die bij de ingangsaansluitklemmen van de UPS
ontstaat gelijk is aan of minder is dan de op de typeplaat van de UPS vermelde
voorwaardelijke kortsluitstroom.
Tabel 6. Minimaal aanbevolen kabel- en zekeringmaten voor externe accu's
UPS-vermogen (kW)
8
10
15
20
30
40
Pos. & neg. lijn [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Accuzekering [A]
63
63
63
63
160
160
PE-kabel [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maximumdoorsnede
geleider
15/20 kW frame, C-model en 30/40 kW frame met gescheiden accu:
massieve draad: 25 mm
2
, draadstreng met bus: 16 mm
2
30/40 kW frame met gemeenschappelijke accu: massieve draad: 90
mm
2
, draadstreng met bus: 70 mm
2
Zie voor informatie over nominale en maximumstroomwaarden voor nominaal vermogen
en spanning de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding.
Voor de optionele externe gescheiden accu zijn aparte aansluitklemmen voor beide accu's
(kasten) beschikbaar. Zie paragraaf 2.3.1.
OPMERKING: Dit product levert geen externe bescherming tegen overstroom, maar dit is
wel vereist door de regelgeving. Zie tabellen 4 en 5 voor eisen met betrekking tot de
bedrading. De gebruiker moet een eventueel vereiste vergrendelbare uitgangsafkoppeling
leveren.
Tabel 7. Aandraaimomenten van UPS voedingskabelaansluitingen
UPS-frame
Functie
Vastdraaikoppel Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: accu +/-
3
PE (aarde)
10 Nm voor 16-35 mm
2
draad
6 Nm voor 4-10 mm
2
draad
4 Nm voor 2,5 mm
2
draad
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: accu +/-
6
87
NL
UPS-frame
Functie
Vastdraaikoppel Nm
PE (aarde)
10 Nm voor 16-35 mm
2
draad
6 Nm voor 4-10 mm
2
draad
4 Nm voor 2,5 mm
2
draad
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (aarde)
10 Nm voor 16-35 mm
2
draad
6 Nm voor 4-10 mm
2
draad
4 Nm voor 2,5 mm
2
draad
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (aarde)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Handeling
Ja/Nee
Alle verpakkingsmaterialen en bevestigingen zijn van alle kasten verwijderd.
Alle kasten in het UPS-systeem staan op hun installatielocaties.
Tussen alle kasten die met bouten aan elkaar worden bevestigd is een aardings-
/montageset geplaatst.
Alle leidingen en kabels zijn correct naar de UPS en eventuele hulpkasten geleid.
Alle voedingskabels hebben de juiste maten en zijn correct aangesloten.
Neutrale geleiders zijn volgens de eisen geïnstalleerd of geaard.
Een aardegeleider is op de juiste wijze geïnstalleerd.
Accukabels zijn afgewerkt en op accuconnectors aangesloten.
De shuntafschakeling van de accu en de bedrading van het AUX-contactsignaal zijn
tussen de UPS en de accubeveiliging aangesloten.
LAN-aansluitpunten zijn geïnstalleerd.
Alle LAN-aansluitingen zijn tot stand gebracht.
Airconditioningapparatuur is geïnstalleerd en werkt correct.
Het gebied rondom het geïnstalleerde UPS-systeem is schoon en stofvrij (aanbevolen
wordt om de UPS op een vlakke en voor computers of elektronische apparatuur
geschikte vloer te plaatsen).
Rondom de UPS en andere kasten is voldoende werkruimte aanwezig.
Rondom alle UPS-apparatuur is voldoende verlichting aanwezig.
Een 230 VAC stopcontact bevindt zich binnen 7,5 meter van de UPS-apparatuur.
De voorziening voor uitschakeling van de externe voeding in noodsituaties (REPO =
Remote Emergency Power-Off) is op de installatielocatie geïnstalleerd en de bedrading
is in de UPS-kast aangesloten.
Plaats bij gebruik van EPO in de NC-configuratie een jumper tussen pennen 1 en 2 op
de EPO.
(OPTIE) Alarmrelais en signaaluitgangen zijn correct bedraad.
(OPTIE) Een externe besturing voor het afkoppelen van de accu is op de
installatielocatie geplaatst en de bedrading hiervan is in de UPS- en accukast
88
NL
Handeling
Ja/Nee
aangesloten.
(OPTIE) Accessoires zijn op de betreffende installatielocaties geplaatst en de bedrading
is in de UPS-kast aangesloten.
Het opstarten en de operationele controles worden door een erkende Eaton
Klantenservicetechnicus of door Eaton erkende gekwalificeerde servicemedewerkers
uitgevoerd.
Het uitpakken en uitladen van de UPS wordt weergegeven in afbeeldingen 9.1-9.8.
Controleer voordat u begint met het uitpakken en uitladen van de UPS de TipNTell en
DropNTell indicatoren op de buitenzijde van de verpakking. Als de apparatuur correct in
verticale positie is getransporteerd, moet de indicator intact zijn. Neem als de pijl van de
TipNTell-indicator volledig blauw is geworden of de pijl(en) van de DropNTell-indicator
zwart zijn contact op met de betreffende partijen om incorrect transport te melden.
De UPS is voor transport met bouten op een houten pallet vastgezet. Verplaats voordat u
de kast van de pallet verwijdert deze met een vorkheftruck of een ander hulpmiddel voor
het verplaatsen van apparatuur naar de installatieruimte.
WAARSCHUWING
De UPS-kast is zwaar. Als de instructies voor het uitpakken niet nauwkeurig worden
opgevolgd, kan de kast omvallen en ernstig letsel veroorzaken.
Kantel de UPS-kast niet meer dan 10 graden uit de verticale stand om te voorkomen dat
de kast omvalt.
OPMERKING: Verplaats nadat u de transportbeugels heeft verwijderd de unit direct uit
de buurt van de pallet.
Gebruik nadat u de transportbeugels heeft verwijderd en de stelvoeten heeft ingetrokken
geen vorkheftruck om de unit te verplaatsen terwijl deze nog op de pallet staat. Bedenk
dat de UPS-kast zwaar is en dat zwenkwielen onder de kast aanwezig zijn.
Breng als u de kast van zijn oorspronkelijke installatielocatie verwijdert en op een pallet
naar een nieuwe locatie verplaatst de stelvoeten omlaag tot de kast niet op de
zwenkwielen steunt en bevestig de transportbeugels aan de kast en de pallet.
De gebruiker moet de bedrading voor aansluiting van de UPS op de lokale voedingsbron
leveren. Laat de installatie van de UPS aan een lokale, gekwalificeerde elektricien over.
Laat de installatie-inspectie, de eerste opstart van de UPS en de installatie van een extra
accukast door een erkende Eaton klantenservicemonteur of door Eaton erkende
servicemedewerkers uitvoeren.
De installatie van de UPS wordt in afbeeldingen 10.1-10.5 weergegeven.
De UPS-voedingskabelaansluitklemmen worden weergegeven in afbeeldingen 6.1 (91PS
15 kW frame), 6.2 (frame 93PS 20 kW), 7.1 (91PS 30kW frame met een
gemeenschappelijke accu), 7.2 (91PS 30kW frame met een optionele gescheiden accu),
89
NL
8.1 (93PS 40kW frame met een gemeenschappelijke accu) en 8.2 (93PS 40kW frame met
een optionele gescheiden accu).
X1
Gelijkrichteringang
X4/-
Externe accu -
X2
Bypassingang
TB20
Afschakeling externe accu
X3
UPS-uitgang
TB21
Afschakeling externe accu
X4/+
Externe accu +
PE
Beschermende aarde
UPM2
(gescheiden accu)
De UPS communicatieaansluitingen worden in afbeeldingen 5.1 en 5.2 weergegeven. De
aansluitklemmen zijn als volgt:
1. TB11, niet in gebruik
2. TB10, niet in gebruik
3. TB9, niet in gebruik
4. TB8, externe CAN-
afsluiting
5. TB7, externe CAN
6. TB6, Pull Chain-bus
7. USB1, USB-host
(aansluiting op
accessoires)
8. USB2, USB-apparaat
(aansluiting op
computer)
9. MiniSlot 1
10. TB1, signaalingang 1-5
11. TB2, niet in gebruik
12. TB3, niet in gebruik
13. Seriële COM-poort RS-
232
14. MiniSlot 2
15. TB4, EPO
16. TB5, relaisuitgang
Plaats bij installatie van een door de klant geleverd accusysteem dit accusysteem volgens
de aanwijzingen van de fabrikant van de accu en het accusysteem en volgens alle
toepasselijke reglementen en voorschriften.
Zie voor de accuspecificaties de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en
Installatiehandleiding.
De 91PS/93PS 8-40 kW UPS-units zijn altijd voorzien van een interne
accustroomonderbreker die uitsluitend op de interne accu's van de UPS werkt (behalve bij
het C-model, waar de interne accustroomonderbreker voor externe accu's kan worden
gebruikt). De externe accubeveiliging is een cruciaal onderdeel van de externe accukast of
het rek en moet hierin worden geplaatst. Bij de externe accubeveiliging is
signaalbekabeling belangrijk.
Zowel interne als externe accubeveiligingen kunnen afschakelen (uitschakelen) door de
shuntafschakelspoel onder spanning te zetten. De shuntafschakelspoelen van de externe
accustroomonderbrekers worden onder spanning gezet (bestuurd) via connectors TB20 en
TB21 (TB21 uitsluitend beschikbaar in de 8-40 kW UPS met gescheiden accuconfiguratie).
De standaardspanning van de shuntafschakelspoel is 24 VDC.
De accu-afschakelbedrading wordt weergegeven in afbeelding 11. De onderdelen zijn de
volgende:
A
Externe accubeveiliging
3
Pin 3, AUX-contact
1
Pen 1, shuntafschakelspoel +
4
Pin 4, AUX-contact retour
2
Pen 2, shuntafschakelspoel -
Zie voor instructies betreffende de installatie van de externe accukast en
accuvoedingsbekabeling de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en
Installatiehandleiding en de bij de externe accukast geleverde instructiehandleiding. Aard
de kast voor de externe accu/het door de klant geleverde accusysteem op de PE-
aansluitklem 17.
90
NL
De EPO wordt op het bovenste voorpaneel van de UPS op de EPO-connector
aangesloten. De aansluitingen van de EPO-schakelaar worden in afbeelding 12
weergegeven.
Zie voor de installatie van de interface-aansluitingen de Eaton 91PS/93PS UPS 8-40 kW
Gebruikers- en Installatiehandleiding.
Eén algemeen relaiscontact wordt als standaardoptie op de UPS geleverd. Ook is een
alarmcontact aanwezig. De uitgangsrelaisconfiguraties worden in afbeelding 13
weergegeven.
U kunt een normaal gesloten of normaal open contact gebruiken. Bij verandering van de
staat van het contact die u als normaal heeft gespecificeerd, wordt een signaal
gegenereerd. U kunt dit contact op apparatuur in uw pand (bijvoorbeeld een lampje of een
alarmbel) aansluiten, zodat u weet wanneer een alarm op de UPS actief is.
OPMERKING: Gebruik contacten niet bij een hogere spanning dan 30 VAC (RMS) en
30 VDC bij maximaal 5 A.
Zie voor informatie over het bedraden van parallelle 91PS/93PS UPS-systemen de Eaton
91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding.
91
ES
1
PELIGRO
¡Instrucciones importantes de seguridad!
¡Conserve estas instrucciones!
Este documento proporciona instrucciones importantes de seguridad y una breve
instrucción sobre cómo examinar la entrega y cómo instalar el SAI. Esta guía rápida solo
debe utilizarse como una lista de comprobación de instalación en el emplazamiento.
La audiencia objetivo de este manual incluye a los profesionales que planifican y realizan
la instalación del SAI.
PELIGRO
Antes de trabajar en el SAI, lea la totalidad de las instrucciones de instalación que se
encuentran en la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW.
Las instrucciones completas se encuentran disponibles para su descarga en
www.eaton.com/91psand93ps.
Un ingeniero del servicio técnico de Eaton autorizado o personal de servicio cualificado y
autorizado por Eaton se encarga de realizar las operaciones en el interior del SAI. El SAI
no contiene piezas que puedan ser reparadas por el usuario.
El SAI funciona con la red eléctrica, batería o alimentación de bypass. Contiene
componentes con altas corrientes y tensión. Un alojamiento instalado adecuadamente se
conecta a tierra y cuenta con certificación de protección IP20 con respecto a descargas
eléctricas y objetos extraños. No obstante, el SAI es un sistema de alimentación
sofisticado y solo debe instalarlo y mantenerlo personal cualificado.
PELIGRO
Este SAI contiene tensiones letales.
Las baterías suponen un riesgo de descarga eléctrica o de quemaduras debido a
corrientes altas de cortocircuito. Respete las precauciones.
Las baterías podrían contener ALTAS TENSIONES y sustancias CORROSIVAS,
TÓXICAS y EXPLOSIVAS. Debido a la cadena de baterías, los receptáculos de salida
pueden transportar alta tensión incluso cuando el suministro de CA no está conectado al
SAI. Lea las instrucciones de apagado en la Guía de usuario y de instalación.
ADVERTENCIA
El SAI recibe la alimentación de su propia fuente de energía (baterías). Los terminales
de salida pueden estar energizados incluso si el SAI se ha desconectado de una fuente
de CA. Para reducir el riesgo de incendio o descarga eléctrica, instale este SAI en un
lugar interior con control de temperatura y humedad y sin contaminantes conductores.
No apile el alojamiento modelo C del SAI 91PS/93PS encima de otros alojamientos
similares. No apile nada encima del alojamiento del SAI 91PS/93PS. Si el alojamiento
modelo C del SAI 91PS/93PS se instala en una estantería, utilice los soportes
necesarios para impedir que el SAI vuelque o se caiga.
92
ES
ADVERTENCIA
La temperatura ambiente no debe superar 40 °C. No utilice el SAI cerca del agua o con
una humedad excesiva (máximo de 95 %). El sistema no se ha diseñado para su uso en
exteriores.
Antes de realizar trabajos de instalación o mantenimiento, asegúrese de que todas las
fuentes de alimentación de CA y CC estén desconectadas. La alimentación podría
proceder de múltiples fuentes. Asegúrese de la continuidad de PE / conexión a tierra del
sistema.
En un sistema paralelo, los terminales de salida pueden estar energizados incluso si el
SAI se ha desconectado.
Peligro de energía eléctrica. Para evitar lesiones, no intente modificar ningún conector o
cable de la batería.
IMPORTANTE: Asegúrese de desconectar todas las ramas de baterías antes de la
instalación.
PRECAUCIÓN
Las tareas de instalación o mantenimiento en las baterías solo pueden ser realizadas por
personal de servicio técnico cualificado conocedor de las baterías y de las precauciones
requeridas. La instalación y el trabajo de servicio en las baterías es trabajo en línea con
corriente y requiere el uso de herramientas de tensión. Mantenga alejado de las baterías
al personal no autorizado.
Antes de instalar o sustituir las baterías, tenga en cuenta todas las advertencias,
precauciones y notas relativas a la manipulación adecuada. No desconecte las baterías
mientras el SAI se encuentre en el modo Batería.
Asegúrese de que las baterías de repuesto sean de la misma gama y modelo que la
batería instalada originalmente en el SAI. Puede consultar instrucciones más precisas en
el SAI.
Antes de conectar o desconectar terminales de batería, desconecte la fuente de carga
abriendo el disyuntor de la batería correspondiente.
Examine si la batería se ha conectado a tierra involuntariamente. Si es así, retire la
fuente de la tierra. El contacto con cualquier parte de una batería conectada a tierra
puede provocar riesgo de descarga eléctrica.
Deseche las baterías de conformidad con los requisitos locales de eliminación.
No arroje las baterías al fuego. Las baterías pueden explotar cuando se exponen a las
llamas.
Para reducir el riesgo de incendio, realice la conexión solo a un circuito proporcionado
con la corriente nominal máxima del disyuntor de entrada de acuerdo con las normas de
instalación nacionales y locales.
Mantenga la puerta del SAI cerrada y los paneles frontales instalados para garantizar
una corriente de aire de refrigeración adecuada y proteger al personal de tensiones
peligrosas dentro de la unidad.
No instale ni haga funcionar el sistema SAI cerca de fuentes de calefacción de gas o
eléctricas.
Mantenga el entorno de funcionamiento dentro de los parámetros especificados en este
documento. Mantenga el entorno del SAI despejado, limpio y exento de humedad
excesiva.
Respete todos los avisos de PELIGRO, PRECAUCIÓN y ADVERTENCIA fijados en el
interior y exterior de los equipos.
93
ES
2
El Sistema de alimentación ininterrumpida (SAI) Eaton® 91PS/93PS es un sistema
monofásico (91PS) o trifásico (93PS), de estado sólido, de doble conversión, sin
transformadores, de servicio continuo, en línea real. Suministra alimentación CA adaptada
e ininterrumpible a la carga crítica y la protege de fallos de la alimentación. Las potencias
nominales de salida del Eaton 91PS/93PS se basan en módulos de alimentación
ininterrumpida (UPM) con una potencia nominal de 15 kW o 20 kW.
El 91PS/93PS también se encuentra disponible como un modelo C, que consta de la
sección eléctrica del bastidor de 15/20 kW del SAI 91PS/93PS sin el compartimento de la
batería.
Tabla 1. Potencias nominales del alojamiento del SAI
Bastidor del SAI
Imagen
(Ilustración 1)
Número de UPMs
Potencias nominales
91PS 15 kW
A y B
1
8, 10, 15 kW
91PS 30 kW
C
1 ó 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A y B
1
8, 10, 15 o 20 kW
93PS 40 kW
C
1 ó 2
8, 10, 15, 20, 30 o 40
kW
Las piezas principales del SAI 91PS/93PS 8-40 kW se muestran en la ilustración 2. Las
piezas principales son las siguientes:
1. Panel de control
2. Cerrojo de la puerta
3. Módulo de alimentación (UPM)
4. Batería interna (no en modelos C)
5. Área de comunicaciones
6. Conmutador de entrada
7. Señales del disyuntor
8. Conmutador de bypass de mantenimiento
(opcional)
.
PELIGRO
Este SAI contiene tensiones letales.
Un ingeniero del servicio técnico de Eaton autorizado o personal de servicio cualificado y
autorizado por Eaton se encarga de realizar las operaciones en el interior del SAI. El SAI
no contiene piezas que puedan ser reparadas por el usuario.
Para conocer las instrucciones de seguridad completas, consulte la Guía de usuario y de
instalación del SAI Eaton 91PS/93PS 8-40 kW.
El SAI debe instalarse de acuerdo con las recomendaciones en la Guía de usuario y de
instalación del SAI Eaton 91PS/93PS 8-40 kW.
Use la siguiente secuencia básica de pasos para instalar el SAI:
94
ES
1. Elabore un plan de instalación para el sistema SAI.
2. Prepare su emplazamiento para el sistema SAI.
3. Inspeccione y desembale el alojamiento del SAI.
4. Descargue e instale el alojamiento del SAI y realice el cableado del sistema.
5. Complete la lista de comprobación de la instalación.
6. Disponga de personal de servicio técnico autorizado para realizar las comprobaciones
operativas preliminares y el arranque.
NOTA: Solo un Ingeniero de servicio técnico de Eaton autorizado o personal de servicio
cualificado y autorizado por Eaton deberá realizar el arranque y las comprobaciones
operativas ya que de lo contrario los términos de la garantía especificados en la Garana
dejarán de tener validez.
Antes de instalar el sistema SAI, lea y entienda cómo se aplican estas instrucciones en el
sistema que va a instalar. Utilice los procedimientos e ilustraciones proporcionados para
elaborar un plan lógico para instalar el sistema.
Para que el sistema SAI funcione con la máxima eficiencia, el emplazamiento de
instalación debe cumplir los parámetros ambientales descritos en la Guía de usuario y de
instalación del SAI Eaton 91PS/93PS 8-40 kW.
El entorno de instalación debe cumplir los requisitos de peso y tamaño del SAI
proporcionados en las Tablas 2 y 3.
Las dimensiones del alojamiento del SAI se muestran en la ilustración 1. Tenga en cuenta
que la dimensión de profundidad (750 mm) incluye los prensa cables.
Tabla 2. Pesos del alojamiento del SAI con embalaje de cartón
Modelo C 8-20 kW
(Ilustración 1,
imagen A)
Bastidor de 15/20
kW*
(Ilustración 1,
imagen B)
Bastidor de 30/40
kW* (Ilustración 1,
imagen C)
Peso de envío
98 kg
293 kg
558 kg
Peso instalado
86 kg
280 kg
532 kg
Carga del suelo
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Se incluyen baterías internas máximas con todos los modelos.
Los alojamientos del SAI utilizan refrigeración forzada por circulación de aire para regular
la temperatura interna de los componentes. De forma predeterminada, las entradas de aire
se encuentran en la parte delantera y las salidas se encuentran en la parte posterior del
alojamiento; consulte la ilustración 3. Deje holgura en la parte frontal y por detrás de cada
alojamiento para que se produzca una circulación de aire adecuada. Asegúrese de que el
aire de refrigeración que penetra en el SAI no supere +40 °C. Para conocer los requisitos
de ventilación, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40
kW.
95
ES
Tabla 3. Holguras mínimas del alojamiento del SAI
Bastidor de 15/20 kW
(Ilustración 1,
imágenes A y B)
Bastidor de 30/40 kW
(Ilustración 1,
imagen C)
Desde la parte superior del
alojamiento
500 mm
500 mm
Desde la parte frontal del
alojamiento
500 mm
650 mm
Desde la parte posterior del
alojamiento
150 mm
250 mm
Desde la parte lateral del
alojamiento
0 mm
0 mm
La temperatura ambiente de funcionamiento y la humedad recomendadas para el sistema
SAI se muestran en las ilustraciones 4.1 y 4.2. Se recomienda una temperatura ambiente
de +20 °C a +25 °C para obtener una vida útil prolongada de las baterías VRLA.
Tabla 4. Cable multiconductor mínimo recomendado y tamaños de fusibles para la entrada del
rectificador y de bypass y cables de salida del SAI (entrada trifásica, salida trifásica)
Potencia nominal del SAI
93PS (kW)
8
10
15
20
30
40
Cable [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Fusible del rectificador [A]
20
20
32
40
63
80
Fusible de bypass [A]
20
20
32
40
63
80
Cable PE [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Sección transversal
máxima del conductor
Bastidor de 20 kW y modelo C de 20 kW: cable macizo de 16 mm
2
,
cable trenzado con férula: 10 mm
2
Bastidor de 40kW: cable macizo de 70 mm
2
, cable trenzado con
férula: 50 mm
2
Tabla 5. Cable multiconductor mínimo recomendado y tamaños de fusibles para la entrada del
rectificador y de bypass y cables de salida del SAI (entrada trifásica, salida monofásica)
Potencia nominal del SAI
91PS (kW)
8
10
15
20
30
Cable del rectificador
[mm
2
]
2,5
4
10
10
16
Fusible del rectificador [A]
20
20
32
40
63
Bypass, cable de salida
[mm
2
]
10
16
25
35
70
Fusible de bypass [A]
50
63
80
100
160
96
ES
Potencia nominal del SAI
91PS (kW)
8
10
15
20
30
Cable PE [mm
2
]
10
16
16
16
35
Sección transversal
máxima del conductor,
bastidor de 15 kW y
modelo C de 15 kW
Rectificador: cable macizo de 16 mm
2
, cable trenzado
con férula: 10 mm
2
Bypass/salida: cable macizo de 70 mm
2
, cable trenzado
con férula: 50 mm
2
Sección transversal
máxima del conductor,
bastidor de 30 kW
Rectificador: cable macizo de 70 mm
2
, cable trenzado
con férula: 50 mm
2
Bypass/salida: cable macizo de 95 mm
2
, cable trenzado
con férula: 95 mm
2
PRECAUCIÓN
Asegúrese de que la corriente de cortocircuito potencial resultante en los terminales de
entrada del SAI sea igual o inferior que la corriente de cortocircuito condicional declarada
en la etiqueta de clasificación del SAI.
Tabla 6. Tamaños mínimos recomendados de cable y de fusible para banco de batería externa
Valores nominales del SAI
(kW)
8
10
15
20
30
40
Línea pos. y neg. [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Fusible de batería [A]
63
63
63
63
160
160
Cable PE [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Sección transversal
máxima del conductor
Bastidor de 15/20 kW, modelo C y bastidor de 30/40 kW con batería
independiente: cable macizo: 25 mm
2
, cable trenzado con férula: 16
mm
2
Bastidor de 30/40 kW con batería común: cable macizo: 90 mm
2
,
cable trenzado con férula: 70 mm
2
Si desea información sobre las corrientes nominales y máximas para la potencia y tensión
nominal, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW.
Para la opción de batería separada externa, hay terminales separados para ambos bancos
de la batería (alojamientos), consulte la sección 2.3.1.
NOTA: La protección externa de supresión de sobretensiones no se proporciona con este
producto, aunque las normas la exigen. Consulte las Tablas 4 y 5 para conocer los
requisitos de cableado. Si se requiere un dispositivo de desconexión bloqueable de la
salida, éste será suministrado por el usuario.
97
ES
Tabla 7. Pares de apriete de terminales de cable de alimentación del SAI
Bastidor del SAI
Función
Par de apriete Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: batería +/-
3
PE (tierra)
10 Nm para cable de 16-35 mm
2
6 Nm para cable de 4-10 mm
2
4 Nm para cable de 2,5 mm
2
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: batería +/-
6
PE (tierra)
10 Nm para cable de 16-35 mm
2
6 Nm para cable de 4-10 mm
2
4 Nm para cable de 2,5 mm
2
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (tierra)
10 Nm para cable de 16-35 mm
2
6 Nm para cable de 4-10 mm
2
4 Nm para cable de 2,5 mm
2
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (tierra)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Acción
Sí/No
Todos los materiales y elementos de sujeción del embalaje se han retirado de cada
alojamiento.
Cada alojamiento del sistema SAI se ha colocado en su posición predeterminada de
instalación.
Se ha instalado un kit de conexión a tierra / kit de montaje del alojamiento entre los
alojamientos que se hayan fijado juntos con pernos.
Todos los conductos y cables se han tendido adecuadamente hasta el SAI y hasta
cualquier alojamiento auxiliar.
Todos los cables de alimentación están dimensionados y terminados adecuadamente.
Los conductores de neutro están instalados y unidos a tierra según los requisitos.
Se ha instalado adecuadamente un conductor de puesta a tierra.
Los cables de la batería se terminan y conectan a los conectores de la batería.
El cableado de señal del contacto auxiliar y de disparo de la batería está conectado
desde el SAI hasta el disyuntor de la batería.
Los cables LAN están instalados.
Todas las conexiones LAN se han completado.
Los equipos de aire acondicionado están instalados y funcionan correctamente.
98
ES
Acción
Sí/No
El área que rodea al sistema SAI instalado está limpia y libre de polvo (se recomienda
instalar el SAI en un suelo nivelado adecuado para los equipos informáticos o
electrónicos).
Hay un espacio de trabajo adecuado en torno al SAI y a otros alojamientos.
Se proporciona iluminación adecuada en torno a todos los equipos del SAI.
Una toma de corriente de 230 VCA se encuentra dentro de una distancia de 7,5 metros
de los equipos del SAI.
El dispositivo de apagado remoto de emergencia (REPO) está montado en su posición
predeterminada de instalación y su cableado termina dentro del alojamiento del SAI.
Si el EPO se utiliza en la configuración NC, debe instalarse un puente en el EPO entre
los pines 1 y 2.
(OPCIONAL) Los relés de alarma y las salidas de señal están cableados
adecuadamente.
(OPCIONAL) Existe un control de desconexión remota de la batería montado en su
posición predeterminada de instalación y su cableado termina dentro del alojamiento del
SAI y de la batería.
(OPCIONAL) Los accesorios están montados en sus posiciones predeterminadas de
instalación y el cableado termina dentro del alojamiento del SAI.
Un ingeniero del servicio técnico de Eaton autorizado o un ingeniero de servicio
cualificado y autorizado por Eaton se encarga de realizar el arranque y las
comprobaciones operativas.
El desembalaje y la descarga del SAI se muestran en las ilustraciones 9.1 - 9.8.
Antes de empezar a desembalar y descargar el SAI, compruebe los indicadores TipNTell y
DropNTell de la superficie del embalaje. Si el equipo se ha transportado correctamente en
la posición vertical, los indicadores deben estar intactos. Si la flecha indicadora TipNTell
se ha vuelto toda azul o las puntas de flecha del indicador DropNTell están negras,
contacte con las partes correspondientes para notificar un transporte inadecuado.
Con fines de transporte, el alojamiento del SAI está fijado con pernos a un palé de
madera. Antes de descargar el alojamiento del palé, utilice una carretilla elevadora u otro
equipo de manipulación de materiales para mover el alojamiento hasta la zona de
instalación.
ADVERTENCIA
El alojamiento del SAI es pesado. Si no se respetan estrictamente las instrucciones de
desembalaje, el alojamiento podría volcar y provocar lesiones graves.
No incline el alojamiento del SAI más de 10 grados desde la vertical o el alojamiento
podría volcar.
NOTA: Tras retirar los soportes de envío, saque la unidad inmediatamente del palé.
Tras retirar los soportes de envío y replegar los pies de nivelación, no utilice una
carretilla elevadora para mover la unidad mientras aún se encuentre en el palé. Tenga
en cuenta que el alojamiento del SAI es pesado y que existen ruedas giratorias bajo el
alojamiento.
Si retira el alojamiento de su posición predeterminada de instalación original y se lleva a
una nueva posición sobre un palé, baje los pies de nivelación hasta que el alojamiento
deje de descansar en las ruedas giratorias y fije los soportes de envío al alojamiento y al
palé.
99
ES
El operador tiene que suministrar el cableado para conectar el SAI a la fuente de
alimentación local. La instalación del SAI debe realizarla un electricista cualificado
localmente. La inspección de la instalación y el arranque inicial del SAI, así como la
instalación de un alojamiento de batería adicional, deben realizarse mediante un ingeniero
del servicio técnico de Eaton autorizado o personal de servicio cualificado y autorizado por
Eaton.
La instalación del SAI se muestra en las ilustraciones 10.1-10.5.
Los terminales de cables de alimentación del SAI se muestran en las ilustraciones 6.1
(91PS bastidor de 15 kW), 6.2 (93PS bastidor de 20 kW), 7.1 (91PS bastidor de 30kW con
una batería común), 7.2 (91PS bastidor de 30kW con una opción de batería separada), 8.1
(93PS bastidor de 40kW con una batería común) y 8.2 (93PS bastidor de 40kW con una
opción de batería separada).
X1
Entrada del rectificador
X4/-
Batería externa -
X2
Entrada de bypass
TB20
Disparo de batería externa
X3
Salida del SAI
TB21
Disparo de batería externa
X4/+
Batería externa +
PE
Tierra de protección
UPM2
(batería separada)
Los terminales de comunicación del SAI se muestran en las ilustraciones 5.1 y 5.2. Los
terminales son los siguientes:
1. TB11, no se utiliza
2. TB10, no se utiliza
3. TB9, no se utiliza
4. TB8, terminación CAN
externa
5. TB7, CAN externa
6. TB6, bus de cadena
de tracción
7. USB1, host USB
(conexión a accesorios)
8. USB2, dispositivo USB
(conexión a ordenador)
9. MiniSlot 1
10. TB1, entrada de señal 1-5
11. TB2, no se utiliza
12. TB3, no se utiliza
13. Puerto COM de serie RS-
232
14. MiniSlot 2
15. TB4, EPO
16. TB5, salida de relé
Si instala un sistema de batería suministrado por el cliente, realice la instalación siguiendo
las instrucciones del fabricante de la batería y del sistema de batería, así como todas las
normas y códigos nacionales aplicables.
Para conocer las especificaciones de la batería, consulte la Guía de usuario y de
instalación del SAI Eaton 91PS/93PS 8-40 kW.
Las unidades SAI 91PS/93PS 8-40 kW siempre están equipadas con un disyuntor de
batería interna, que afecta solo a las baterías internas del SAI (excepto para el modelo C,
donde el disyuntor de batería interna puede utilizarse para baterías externas). El disyuntor
de batería externa es una parte crucial del alojamiento o bastidor de la batería externa y
debe colocarse en el mismo. Con el disyuntor de batería externa, el cableado de señal es
importante.
Tanto los disyuntores de batería interna como externa pueden dispararse (desactivarse)
energizando la bobina de disparo. Las bobinas de disparo de los disyuntores de batería
externa se energizan (controlan) mediante los conectores TB20 y TB21 (TB21 disponible
solo en el SAI de 8-40 kW con configuración de batería independiente). La tensión
predeterminada de la bobina de disparo es 24 VCC.
100
ES
El cableado de disparo de la batería se muestra en la ilustración 11. Las piezas son las
siguientes:
A
Disyuntor de batería externa
3
Pin 3, contacto AUX
1
Pin 1, bobina de disparo +
4
Pin 4, retorno de contacto
AUX
2
Pin 2, bobina de disparo -
Si desea instrucciones sobre la instalación del alojamiento de la batería externa y el
cableado de alimentación de la batería, consulte la Guía de usuario y de instalación del
SAI Eaton 91PS/93PS 8-40 kW y el manual de instrucciones que se proporciona con el
alojamiento de la batería externa. Conecte a tierra el alojamiento de la batería externa /
sistema de batería suministrado por el cliente al terminal PE 17.
El EPO se conecta en el panel frontal superior del SAI, en el conector del EPO. Las
conexiones del conmutador EPO se muestran en la ilustración 12.
Si desea información sobre la instalación de las conexiones de la interfaz, consulte la Guía
de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW.
En el SAI se proporciona un contacto de relé de propósito general como función estándar.
También se proporciona un contacto de alarma. Las configuraciones del relé de salida se
muestran en la ilustración 13.
Puede utilizar un contacto normalmente cerrado o normalmente abierto. Si el estado del
contacto cambiara con respecto al estado especificado como normal, se emitirá una señal.
Puede conectar este contacto a los equipos de su instalación (como por ejemplo una
indicación luminosa o un timbre de alarma) para permitirle saber cuándo se activa una
alarma en el SAI.
NOTA: A los contactos no se les debe aplicar una tensión y corriente que superen 30 VCA
(RMS) y 30 VCC a 5 A.
Si desea información sobre el cableado en paralelo de sistemas SAI 91PS/93PS, consulte
la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW.
101
CS
1
NEBEZPEČÍ
Důležité bezpečnostní pokyny!
Uschovejte tuto příručku!
Tato příručka obsahuje důležité bezpečnostní pokyny a stručné pokyny, jak zkontrolovat
dodané zařízení UPS a jak jej správně nainstalovat. Tato rychlá příručka má sloužit jako
kontrolní seznam v místě instalace.
Cílovou skupinou této příručky jsou zkušení odborníci, kteří plánují a provádějí instalaci
zařízení UPS.
NEBEZPEČÍ
Před zahájením prací na zařízení UPS si přečtěte pokyny k instalaci, které jsou uvedeny
v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS UPS 8-40 kW.
Celé znění pokynů si můžete stáhnout z adresy www.eaton.com/91psand93ps.
Zásahy uvnitř zařízení UPS musí provádět autorizovaný servisní technik společnosti
Eaton nebo kvalifikovaný servisní personál pověřený společností Eaton. Uvnitř UPS
nejsou žádné součásti, které může opravit či vyměnit uživatel.
UPS pracuje s napájením ze sítě, z baterií či přes bypass. Obsahuje součásti, kterými
protékají vysoké proudy a na kterých se vyskytuje nebezpečné napětí. Správně
instalovaný UPS je uzemněn a zajišťuje ochranu proti úrazu elektrickým proudem
a vniknutí cizích předmětů se stupněm krytí IP20. Zařízení UPS je nicméně sofistikovaný
napájecí systém a jeho instalaci a servis smí provádět pouze kvalifikovaní pracovníci.
NEBEZPEČÍ
Zařízení UPS pracuje s životu nebezpečným napětím.
Baterie představují nebezpečí úrazu elektrickým proudem či popálením v důsledku
velkého zkratového proudu. Dodržujte bezpečnostní opatření.
Baterie mohou obsahovat VYSOKÉ NAPĚTÍ a AGRESIVNÍ, TOXICKÉ či VÝBUŠNÉ
látky. Kvůli řetězci baterií může být na výstupních svorkách vysoké napětí, i když není
zařízení UPS připojeno ke zdroji střídavého napětí. Přečtěte si pokyny k vypnutí, které
jsou uvedeny v Instalační a uživatelské příručce.
VAROVÁNÍ
Zařízení UPS je napájeno vlastním zdrojem energie (bateriemi). Výstupní svorky mohou
být pod napětím, i když je zařízení UPS odpojeno od zdroje střídavého napětí. Abyste
snížili riziko požáru či úrazu elektrickým proudem, instalujte toto zařízení UPS do
vnitřních prostor s regulovanou teplotou a vlhkostí a bez výskytu vodivých prachových
částic.
Nepokládejte zařízení skříňový model zařízení UPS 91PS/93PS C na žádné další
podobné skříňky. Nepokládejte rovněž nic na skříň zařízení UPS 91PS/93PS. Pokud
skříňový model UPS 91PS/93PS C instalujete na regál, použijte nezbytné podpěry,
kterými zabráníte pádu nebo převrácení zařízení UPS.
102
CS
VAROVÁNÍ
Okolní teplota nesmí překročit 40 °C. Nepoužívejte UPS v blízkosti vody či při nadměrné
vlhkosti (nejvýše 95 %). Systém není určen pro použití ve venkovním prostředí.
Než zahájíte jakékoli instalační či servisní práce, zkontrolujte, zda jsou odpojeny zdroje
střídavého i stejnosměrného napájení. Napájení může přicházet z několika zdrojů. Též je
třeba zajistit uzemnění systému a spojitost vodiče PE.
U systému s paralelním zapojením mohou být výstupní svorky pod napětím, i když je
zařízení UPS vypnuté.
Nebezpečí úrazu elektrickým proudem. Abyste předešli zraněním, nepokoušejte se
upravovat ani opravovat žádné vodiče ani konektory baterií.
DŮLEŽITÉ: Před instalací se ujistěte, že jste odpojili všechny řetězce baterií.
POZOR
Instalovat baterie a provádět jejich servis smějí pouze kvalifikovaní servisní pracovníci se
zkušenostmi s bateriemi a potřebnými opatřeními. Instalace a servisní práce na bateriích
probíhají na živých částech a vyžadují používání nástrojů pro práci pod napětím.
Zamezte přístupu neoprávněných osob k bateriím.
Při instalaci a výměně baterií pamatujte na všechna varování, upozornění a poznámky
týkající se správné manipulace s nimi. Neodpojujte baterie, je-li UPS v bateriovém
režimu.
Zkontrolujte, zda jsou náhradní baterie stejného typu a počtu jako baterie, které byly
v UPS původně instalovány. Přesnější pokyny jsou uvedeny na UPS.
Před připojením či odpojením bateriových svorek odpojte nabíjecí zdroj. Provedete to
rozpojením příslušného jističe bateriového obvodu.
Zkontrolujte, zda není baterie neúmyslně uzemněna. Pokud ano, uzemnění odstraňte.
Kontakt s libovolnou částí uzemněné baterie představuje nebezpečí úrazu elektrickým
proudem.
Baterie likvidujte v souladu s místními předpisy.
Nevhazujte baterie do ohně. Jsou-li vystaveny ohni, mohou explodovat.
Abyste snížili riziko požáru, připojujte zařízení pouze k obvodu vybavenému jističem
maximálního vstupního proudu dimenzovaným v souladu s národními a místními
elektroinstalačními předpisy podle údajů, které obsahuje.
Abyste zajistili správný tok chladicího vzduchu a chránili osoby před nebezpečným
napětím uvnitř zařízení, udržujte dveře UPS zavřené a přední panely namontované.
Neinstalujte ani neprovozujte systém UPS v blízkosti plynových ani elektrických topidel.
Dbejte na to, aby provozní prostředí odpovídalo parametrům uvedeným v tomto
dokumentu. Okolí UPS udržujte bez nepořádku, čisté a bez nadměrné vlhkosti.
Věnujte pozornost všem symbolům NEBEZPEČÍ, POZOR a VAROVÁNÍ umístěným
uvnitř a vně zařízení.
103
CS
2
Nepřerušitelný záložní zdroj Eaton® 91PS/93PS (UPS) je kontinuální beztransformátorový
energeticky nezávislý jednofázový (91PS) nebo třífázový (93PS) systém s technologií
online a dvojitou konverzí. Dodává upravený nepřerušovaný střídavý proud (AC) kritické
zátěží a chrání ji před výpadky proudu. Jmenovité výkony zařízení Eaton řady 91PS/93PS
jsou založeny na modulech nepřerušovaného napájení (UPM) o jmenovitém výkonu 15 kW
nebo 20 kW.
Model 91PS/93PS je rovněž v dispozici jako skříňový model C, který obsahuje elektrickou
část rámu 91PS/93PS UPS 15/20 kW bez prostoru na baterie.
Tabulka 1. Parametry skříně UPS
Rám UPS
Obrázek
(Ilustrace 1)
Počet UPM
Technické údaje
91PS 15 kW
A a B
1
8, 10, 15 kW
91PS 30 kW
C
1 nebo 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A a B
1
8, 10, 15 nebo 20 kW
93PS 40 kW
C
1 nebo 2
8, 10, 15, 20, 30 nebo
40 kW
Hlavní části modelu 91PS/93PS 8-40 kW UPS jsou uvedeny na obrázku 2. Hlavní části:
1. Ovládací panel
2. Západka dveří
3. Výkonový modul (UPM)
4. Interní baterie (nejsou ve skříňovém
modelu C)
5. Komunikační rozhraní
6. Spínač vstupu
7. Bateriový jistič
8. Spínač údržbového bypassu (volitelný)
.
NEBEZPEČÍ
Zařízení UPS pracuje s životu nebezpečným napětím.
Zásahy uvnitř zařízení UPS musí provádět autorizovaný servisní technik společnosti
Eaton nebo kvalifikovaný servisní personál pověřený společností Eaton. Uvnitř UPS
nejsou žádné součásti, které může opravit či vyměnit uživatel.
Kompletní bezpečnostní pokyny naleznete v Instalační a uživatelské příručce k zařízení
Eaton 91PS/93PS 8-40 kW UPS.
Zařízení UPS je třeba instalovat podle doporučení uvedených v Instalační a uživatelské
příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS.
Při instalaci zařízení UPS dodržujte následující základní postup:
1. Vytvořte si plán instalace systému UPS.
104
CS
2. Připravte pro systém UPS své prostory.
3. Zkontrolujte a vybalte skříň UPS.
4. Vyjměte a nainstalujte skříň UPS a systém zapojte.
5. Vyplňte kontrolní seznam pro instalaci.
6. Požádejte pověřené pracovníky servisu, aby provedli kontrolu před spuštěním
a samotné spuštění.
POZNÁMKA: Úvodní a provozní revize musí provádět technik zákaznické péče společnosti
Eaton nebo kvalifikovaný personál pověřený společností Eaton, jinak pozbývají platnosti
záruční podmínky uvedené v Záruce.
Před instalací systému UPS si přečtěte tyto pokyny a ujistěte se, že rozumíte jejich
souvislosti s vámi instalovaným systémem. Podle postupů a ilustrací sestavte logický
postup instalace systému.
Aby systém UPS pracoval co nejefektivněji, musí místo instalace splňovat parametry
prostředí uvedené v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW
UPS.
Prostředí místa instalace musí splňovat hmotnostní a rozměrová doporučení pro zařízení
UPS uvedená v tabulce 2 a 3.
Rozměry skříně UPS jsou uvedeny na obrázku 1. Mějte na paměti, že hloubkové rozměry
(750 mm) jsou včetně kabelových průchodek.
Tabulka 2. Hmotnost skříně UPS v kartonovém obalu
Model C 8-20 kW
(Ilustrace 1,
obr. A)
rám 15/20 kW*
(Ilustrace 1, obr. B)
30/40 kW rám*
(Ilustrace 1, obr. C)
Přepravní hmotnost
98 kg
293 kg
558 kg
Hmotnost po instalaci
86 kg
280 kg
532 kg
Zatížení podlahy
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* U všech modelů jsou započteny interní baterie maximální možné kapacity.
Skříně UPS používají nucené chlazení vzduchem, které reguluje teplotu vestavěných
součástí. Otvory pro nasávání vzduchu jsou standardně na přední straně skříně a výfukové
otvory jsou na zadní straně, jak ukazuje obrázek 3. Kvůli řádnému proudění vzduchu mu
být před a za každou skříní dostatek volného prostoru. Ujistěte se, že chladicí vzduch
vstupující do zařízení UPS nemá vyšší teplotu než +40°C. Požadavky na ventilaci jsou
uvedeny v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS.
105
CS
Tabulka 3. Minimální požadované volné místo kolem skříně UPS
rám 15/20 kW
(Ilustrace 1,
obr. A a B)
rám 30/40 kW
(Ilustrace 1,
obr. C)
Nad skříní
500 mm
500 mm
Před skříní
500 mm
650 mm
Za skříní
150 mm
250 mm
Po stranách skříně
0 mm
0 mm
Doporučená teplota a vlhkost okolního prostředí pro systém UPS je uvedena na obrázku
4.1 a 4.2. Doporučujeme zajistit teplotu prostředí v rozsahu od +20 °C do +25 °C.
Dosáhnete tak dlouhé životnosti baterií VRLA.
Tabulka 4. Minimální doporučený průřez vícevodičového kabelu, dimenzování pojistky pro
usměrňovač a bypass a průřez kabelu pro výstup z UPS (3fázový vstup, 3fázový výstup)
93PS výkon UPS (kW)
8
10
15
20
30
40
Kabel [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Pojistka usměrňovače [A]
20
20
32
40
63
80
Pojistka bypassu [A]
20
20
32
40
63
80
Kabel PE [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maximální průřez vodiče
20kW rám a 20kW skříňový model: pevný vodič 16 mm
2
, spletený
vodič s ochranným kroužkem: 10 mm
2
40kW rám: pevný vodič 70 mm
2
, spletený vodič s ochranným
kroužkem: 50 mm
2
Tabulka 5. Minimální doporučený průřez vícevodičového kabelu, dimenzování pojistky pro
usměrňovač a bypass a průřez kabelu pro výstup z UPS (3-fázový vstup, 1-fázový výstup)
91PS výkon UPS (kW)
8
10
15
20
30
Kabel usměrňovače [mm
2
]
2,5
4
10
10
16
Pojistka usměrňovače [A]
20
20
32
40
63
Bypass, kabel výstupu
[mm
2
]
10
16
25
35
70
Pojistka bypassu [A]
50
63
80
100
160
Kabel PE [mm
2
]
10
16
16
16
35
Maximální průřez vodiče,
15 kW rám a 15 kW model C
Usměrňovač: pevný vodič 16 mm
2
, spletený vodič s
ochranným kroužkem: 10 mm
2
Bypass/výstup: pevný vodič 70 mm
2
, spletený vodič s
ochranným kroužkem: 50 mm
2
106
CS
91PS výkon UPS (kW)
8
10
15
20
30
Maximální průřez vodiče,
30 kW rám
Usměrňovač: pevný vodič 70 mm
2
, spletený vodič s
ochranným kroužkem: 50 mm
2
Bypass/výstup: pevný vodič 95 mm
2
, spletený vodič s
ochranným kroužkem: 95 mm
2
POZOR
Zkontrolujte, zda případný zkratový proud na vstupních svorkách UPS je menší či roven
podmíněnému zkratovému proudu uvedeném na typovém štítku UPS.
Tabulka 6. Minimální doporučený průřez kabelu a dimenzování pojistky pro externí baterie
Výkon UPS (kW)
8
10
15
20
30
40
Kladný a záporný vodič
[mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Pojistka baterie [A]
63
63
63
63
160
160
Kabel PE [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maximální průřez vodiče
15/20 kW rám, model C a 30/40 kW rám se samostatnou baterií:
pevný vodič: 25 mm
2
, spletený vodič s ochranným kroužkem: 16
mm
2
30/40 kW rám se společnou baterií: pevný vodič: 90 mm
2
, spletený
vodič s ochranným kroužkem: 70 mm
2
Informace o jmenovitých a maximálních proudech a napětí jsou uvedeny v Instalační a
uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS.
Pro možnost použití externí samostatné baterie, je zařízení vybaveno samostatnými
svorkami pro obě baterie (skříně), viz oddíl 2.3.1.
POZNÁMKA: Externí nadproudová ochrana není součástí tohoto produktu, předpisy ji však
vyžadují. Požadavky na kabeláže viz Tabulka 4 a 5. Pokud je vyžadováno uzamykatelné
zařízení pro odpojení výstupu, musí jej zajistit uživatel sám.
Tabulka 7. Utahovací momenty pro svorky napájecích kabelů UPS
Rám UPS
Funkce
Utahovací moment (Nm)
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: Externí baterie +/-
3
PE (uzemnění)
10 Nm pro vodič 16-35 mm
2
6 Nm pro vodič 4-10 mm
2
4 Nm pro vodič 2,5 mm
2
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: Externí baterie +/-
6
PE (uzemnění)
10 Nm pro vodič 16-35 mm
2
6 Nm pro vodič 4-10 mm
2
4 Nm pro vodič 2,5 mm
2
107
CS
Rám UPS
Funkce
Utahovací moment (Nm)
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (uzemnění)
10 Nm pro vodič 16-35 mm
2
6 Nm pro vodič 4-10 mm
2
4 Nm pro vodič 2,5 mm
2
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (uzemnění)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Činnost
Ano/Ne
Ze skříně byl odstraněn veškerý balicí materiál a přepravní držáky.
Všechny skříně systému UPS byly umístěny na místo instalace.
Mezi všemi skříněmi, které mají být sešroubovány dohromady, bylo instalováno uzemnění /
montážní sada.
Všechna vedení a kabely mezi zařízením UPS a pomocnými skříněmi jsou řádně instalovány.
Všechny napájecí kabely jsou správně dimenzované a mají správné zakončení.
Nulové vodiče jsou instalovány a uzemněny podle požadavků.
Zemnicí vodič je řádně instalován.
Kabely baterií jsou zakončeny a připojeny ke svorkám.
Mezi UPS a bateriovým jističem je zapojena kabeláž ovládání cívky vypínače a pomocného
signalizačního kontaktu.
Je instalován přívod LAN.
Byla provedena všechna připojení LAN.
Klimatizace je řádně zapojená a funguje správně.
Prostor v místě instalace systému UPS je čistý a bezprašný (doporučujeme umístit UPS na
rovnou podlahu vhodnou pro počítače či elektronická zařízení).
Okolo skříně UPS a ostatních skříní je dostatek prostoru.
Veškerá zařízení systému UPS jsou dostatečně osvětlena.
Nejdále ve vzdálenosti 7,5 metru od zařízení UPS je k dispozici zásuvka s napájením
230 VAC.
Zařízení REPO (Dálkové nouzové vypnutí) je namontováno na svém místě a vedení od něj je
zapojeno do skříně UPS.
Je-li spínač EPO (nouzové vypnutí) použit jako rozpínací kontakt, je mezi piny 1 a 2 spínače
EPO instalována propojka.
(VOLITELNĚ) Relé alarmu a signálové vstupy jsou řádně zapojeny.
(VOLITELNĚ) Dálkové ovládání bateriového jističe je namontováno na správném místě
a vedení je zapojeno do skříně s UPS a baterií.
(VOLITELNĚ) Příslušenství a jeho kabeláž jsou namontovány a připojeny do skříně UPS.
Úvodní a provozní revize provádí autorizovaný technik péče o zákazníky společnosti Eaton
nebo kvalifikovaný servisní technik pověřený společností Eaton.
108
CS
Rozbalení a vyložení zařízení UPS je znázorněno na obrázku 9.1 9.8.
Než začnete UPS vybalovat, zkontrolujte indikátory TipNTell a DropNTell na povrchu
obalu. Pokud bylo zařízení převáženo správně ve svislé poloze, měly by být indikátory
neporušené. Pokud šipka ukazatele TipNTell zcela zmodrá nebo bude hlava či hlavy
ukazatele DropNTell černé, spojte se s příslušnou stranou a nahlaste nesprávnou
přepravu.
Během přepravy je skříň UPS přišroubována k dřevěné paletě. Než skříň z palety sundáte,
přesuňte ji pomocí paletového vozíku či jiné manipulační techniky na místo instalace.
VAROVÁNÍ
Skříň UPS je těžká. Pokud se nebudete přesně držet pokynů pro rozbalování, může dojít
k jejímu převrácení a sledně k vážnému zranění.
Nenaklánějte skříň UPS o více než 10° od vertikální roviny, jinak se může převrátit.
POZNÁMKA: Poté, co přepravní konzoly odstraníte, zařízení okamžitě přesuňte z palety.
Po odstranění přepravních konzol a zatažení vyrovnávacích nohou se zařízením, dokud
je ještě na paletě, nemanipulujte pomocí vysokozdvižného vozíku. Skříň UPS je těžká
a zespodu je opatřena pojezdovými kolečky.
Pokud skříň z místa původní instalace přesouváte na nové místo a transportujete ji na
paletě, vysuňte vyrovnávací nohy tak, aby skříň neležela na kolečkách, a připojte ke
skříni a paletě přepravní konzole.
Zákazník musí zajistit kabeláž pro připojení zařízení UPS k místnímu zdroji napájení.
Instalaci UPS musí provádět elektrikář s kvalifikací podle místních předpisů. Kontrolu
instalace a prvotní spuštění zařízení UPS včetně instalace externí bateriové skříně smí
provádět pouze autorizovaný servisní technik společnosti Eaton nebo kvalifikovaný
servisní personál pověřený společností Eaton.
Instalace zařízení UPS je znázorněna na obrázku 10.1-10.5.
Svorkovnice napájecích kabelů zařízení UPS jsou znázorněny na obrázky 6.1 (rám 91PS
15 kW), 6.2 (rám 93PS 20 kW), 7.1 (rám 91PS 30kW se společnou baterií), 7.2 (rám 91PS
30kW s možností samostatné baterie), 8.1 (rám 93PS 40kW se společnou baterií) a 8.2
(rám 93PS 40kW s možností samostatné baterie).
X1
Vstup usměrňovače
X4/-
Externí baterie -
X2
Vstup bypassu
TB20
Vypnutí externí baterie
X3
Výstup UPS
TB21
Vypnutí externí baterie
X4/+
Externí baterie +
PE
Ochranné uzemnění
UPM2
(samostatná baterie)
109
CS
Komunikační svorkovnice zařízení UPS jsou popsány na obrázku 5.1 a 5.2. Svorkovnice:
1. TB11, nepoužito
2. TB10, nepoužito
3. TB9, nepoužito
4. TB8, zakončení
externí CAN
5. TB7, externí CAN
6. TB6, sběrnice
paralelní komunikace
7. USB1, USB host
(připojení k počítači)
8. USB2, USB device
(připojení k počítači)
9. MiniSlot 1
10. TB1, signální vstup 15
11. TB2, nepoužito
12. TB3, nepoužito
13. Sériový port COM RS-232
14. MiniSlot 2
15. TB4, EPO
16. TB5, výstup relé
Pokud provádíte instalaci bateriového systému dodaného zákazníkem, instalujte jej podle
pokynů jeho výrobce, výrobce baterií a v souladu se všemi příslušnými předpisy a kony.
Specifikace baterie naleznete v Instalační a uživatelské příručce k zařízení Eaton
91PS/93PS 8-40 kW UPS.
Zařízení UPS 91PS/93PS 8-40 kW jsou vždy vybavena jističem interní baterie, který má
vliv pouze na interní baterie zařízení UPS (s výjimkou skříňového modelu C, u kterého lze
jistič interní baterie použít také pro externí baterie). Jistič externích baterií je velmi
důležitou součástí skříně nebo racku s externími bateriemi a musí v něm být umístěn. U
jističe externích baterií je důležité připojení signálních kabelů.
Jističe interních i externích baterií lze aktivovat (rozepnout) připojením napětí na cívku
jejich jističe. Cívky externích bateriových jističů jsou napájeny (řízeny) přes konektory TB20
a TB21 (konektor TB21 je obsažen pouze v zařízení UPS 8–40 kW se samostatnou
konfigurací baterie). Standardní napětí cívky je 24 VDC.
Zapojení vypínací cívky je uvedeno na obrázku 11. Jednotlivé části:
A
Externí bateriový jistič
3
Pin 3, pomocný kontakt
1
Pin 1, vypínací cívka +
4
Pin 4, zpětný vodič
pomocného kontaktu
2
Pin 2, vypínací cívka -
Pokyny k instalaci skříně externí baterie a jejího připojení naleznete v Instalační a
uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS a příručce s pokyny, která
byla dodána spolu se skříní externí baterie. Skříň externí baterie či zákazníkem dodaný
bateriový systém uzemněte na svorku PE 17.
Spínač EPO je připojen k přednímu hornímu panelu zařízení UPS ke konektoru
označenému EPO. Přípojky spínače EPO jsou uvedeny na obrázku 12.
Informace o instalaci přípojek rozhraní naleznete v Instalační a uživatelské příručce k
zařízení Eaton 91PS/93PS 8-40 kW UPS.
110
CS
Standardní součástí zařízení UPS je jeden univerzální reléový kontakt. K dispozici je také
kontakt alarmu. Konfigurace výstupního relé jsou uvedeny na obrázku 13.
Lze jej použít jako spínací či rozpínací kontakt. Pokud se stav kontaktu změní ze stavu,
který jste stanovili jako normální, je vyslán signál. Tento kontakt můžete připojit k zařízení
ve vašich prostorách (například ke světelné signalizaci nebo ke zvukovému alarmu), které
vás poté varuje, že došlo k alarmu na zařízení UPS.
POZNÁMKA: Kontakty nepoužívejte, pokud napětí přesahuje 30 VAC (efektivně) nebo
30 VDC při max. 5 A.
Informace o systémech 91PS/93PS UPS s paralelní elektroinstalací naleznete v Instalační
a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS.
111
PL
1
NIEBEZPIECZEŃSTWO
Ważne wskazówki bezpieczeństwa!
Te instrukcje należy zachować!
Ten dokument zawiera ważne instrukcje bezpieczeństwa oraz krótką instrukcję dotyczącą
kontroli dostawy jednostki UPS oraz sposobu jej montażu. Skrócona instrukcja powinna być
wykorzystywana wyłącznie jako lista kontrolna w miejscu montażu.
Dokument skierowany jest do doświadczonych profesjonalistów, którzy planują i wykonują
montaż jednostki UPS.
NIEBEZPIECZEŃSTWO
Przed wykonaniem prac przy jednostce UPS należy przeczytać wszystkie instrukcje dotyczące
montażu zawarte w instrukcji obsługi i montażu Eaton 91PS/93PS UPS 8-40 kW.
Pełne instrukcje są dostępne do pobrania na stronie www.eaton.com/91psand93ps.
Prace wewnątrz jednostki UPS może wykonywupoważniony technik serwisu firmy Eaton
lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton. Wewnątrz jednostki UPS
nie ma żadnych elementów nadających się do serwisowania przez użytkownika.
Jednostka zasilająca UPS może pracować z następującymi źródłami zasilania: sieciowym,
bateryjnym lub obejściowym (układ bypassu). Zawiera podzespoły, które znajdują się pod
wysokim napięciem i przewodzą prąd o dużym natężeniu. Prawidłowo zamontowana szafa jest
uziemiona i zapewnia stopień ochrony IP20 przed porażeniem elektrycznym i przenikaniem
materiałów obcych. Jednostka UPS jest zaawansowanym systemem zasilania i powinna być
montowana oraz serwisowana wyłącznie przez wykwalifikowany personel.
NIEBEZPIECZEŃSTWO
W tej jednostce UPS występują napięcia o wartościach zagrażających życiu.
Baterie stwarzają ryzyko porażenia prądem elektrycznym lub oparzenia wywołanych prądem
zwarcia o wysokim natężeniu. Należy przestrzegać środków ostrożności.
Baterie zawierają ŻRĄCE, TRUJĄCE i WYBUCHOWE substancje. Są też źródłem
WYSOKIEGO NAPIĘCIA. Z powodu zestawu baterii gniazdo wyjściowe może być pod
wysokim napięciem, nawet jeśli źródło prądu przemiennego nie jest podłączone do jednostki
UPS. Proszę przeczytać instrukcje dotyczące wyłączania zawarte w instrukcji obsługi i
montażu.
OSTRZEŻENIE
Jednostka UPS jest zasilana przez własne źródło energii (baterie). Na zaciskach wyjściowych
może być obecne napięcie nawet wtedy, gdy jednostka UPS jest odłączona od źródła prądu
przemiennego. Aby zmniejszyć ryzyko powstania pożaru lub porażenia prądem elektrycznym,
jednostkę UPS należy instalować w środowisku o kontrolowanej temperaturze i wilgotności,
wewnątrz budynku.
Nie kłaść szafy UPS 91PS/93PS model C na górze żadnej innej podobnej szafy. Nie kłaść
żadnych przedmiotów na górze szafy UPS 91PS/93PS. Jeśli szafa UPS 91PS/93PS model C
jest zamontowana na półce, należy użyć odpowiednich podpór, aby uchronić jednostkę UPS
przed przechyleniem lub upadkiem.
112
PL
OSTRZEŻENIE
Temperatura otoczenia nie może przekraczać 40 °C. Jednostki UPS nie należy eksploatować
w pobliżu wody lub w miejscu o nadmiernej wilgotności (maksymalnie 95%). Urządzenie nie
jest przeznaczone do użytkowania na zewnątrz budynków.
Przed rozpoczęciem dowolnych prac montażowych lub serwisowych należy upewnić się, że
urządzenie zostało odłączone od wszystkich źródeł zasilania prądem zmiennym (AC) i stałym
(DC). Zasilanie może pochodzić z wielu źródeł. Należy również zapewnić ciągłość
uziemienia/przewodu ochronnego systemu.
W systemie równoległym na zaciskach wyjściowych może być obecne napięcie nawet wtedy,
gdy jednostka UPS jest wyłączona.
Zagrożenie ze strony energii elektrycznej. Aby uniknąć obrażeń ciała, nie podejmować prób
zmiany żadnych przewodów lub złączy baterii.
WAŻNE: Przed montażem należy zapewnić odłączenie wszystkich zestawów baterii.
PRZESTROGA
Montaż baterii lub związane z nimi prace serwisowe mogą wykonywać wykwalifikowani
pracownicy serwisu posiadający wiedzę w zakresie baterii i wymaganych środków ostrożności.
Prace montażowe i serwisowe na bateriach są wykonywane pod napięciem, dlatego też
wymagają zastosowania specjalnych narzędzi. Nieupoważniony personel nie może mieć z
bateriami jakiejkolwiek styczności.
Przed montażem lub wymianą baterii należy zapoznać się ze wszystkimi ostrzeżeniami,
przestrogami i uwagami dotyczącymi prawidłowej obsługi. Nie odłączać baterii, gdy UPS
pracuje w trybie Baterii.
Należy upewnić się, że nowa bateria ma ten sam numer i jest tego samego typu, co bateria
oryginalnie zainstalowana w jednostce UPS. Dokładne instrukcje znajdują się na jednostce
UPS.
Przed podłączeniem lub odłączeniem zacisków baterii należy odłączyć źródło ładowania przez
otwarcie wyłącznika obwodu baterii.
Sprawdzić, czy bateria nie została uziemiona w sposób niezamierzony. Jeśli tak, należy
usunąć źródło uziemienia. Dotknięcie jakiejkolwiek części uziemionej baterii może stanowić
zagrożenie porażeniem prądem elektrycznym.
Baterie należy utylizować zgodnie z lokalnymi wymaganiami w zakresie utylizacji.
Nie wrzucać baterii do ognia. Wystawienie baterii na dzianie ognia może spowodować
wybuch.
Aby zmniejszyć ryzyko pożaru, połączenie należy wykonać wyłącznie do obwodu
wyposażonego w odłącznik wejściowy o wartości znamionowej prądu, zgodnie z
obowiązującymi krajowymi i lokalnymi zasadami instalacji.
Drzwi UPS powinny być przez cały czas zamknięte, a przednie panele zamontowane, aby
zapewnić właściwy przepływ powietrza chłodzącego i chronić personel przed niebezpiecznym
napięciem obecnym wewnątrz jednostki.
Nie wolno montować ani eksploatować systemu UPS w pobliżu źródeł gazu lub ciepła
wytwarzanego przez prąd elektryczny.
Parametry środowiska pracy należy utrzymywać w granicach podanych w tym dokumencie.
Otoczenie jednostki UPS musi być uporządkowane, czyste i wolne od nadmiernej wilgoci.
Stosować się do wszystkich tabliczek NIEBEZPIECZEŃSTWO, PRZESTROGA i
OSTRZEŻENIE umieszczonych wewnątrz i na zewnątrz sprzętu.
113
PL
2
Zasilacz bezprzerwowy (UPS) 91PS/93PS firmy Eaton® to prawdziwy beztransformatorowy o
podwójnej konwersji, stały, jednofazowy (91PS) lub trójfazowy (93PS) system online do pracy
ciągłej. Dostarcza ustabilizowane i bezprzerwowe zasilanie prądu zmiennego do krytycznego
obciążenia i chroni go przed awariami zasilania. Znamionowa moc wyjściowa systemu
91PS/93PS firmy Eaton zależy od liczby bezprzerwowych modułów zasilających (UPM), z
których każdy ma moc 15 kW lub 20 kW.
91PS/93PS jest również dostępny jako model C, który składa się z części elektrycznej ramy
zwymiarowanej do mocy 15/20kW systemu UPS 91PS/93PS bez przedziału na baterie.
Tabela 1. Wartości znamionowe szafy UPS
Rama systemu UPS
Rysunek
(Ilustracja 1)
Liczba UPM
Wartości znamionowe
91PS 15 kW
A i B
1
8, 10, 15 kW
91PS 30 kW
C
1 lub 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A i B
1
8, 10, 15 lub 20 kW
93PS 40 kW
C
1 lub 2
8, 10, 15, 20, 30 lub 40
kW
Główne części systemu UPS 91PS/93PS 8-40 kW przedstawia rysunek 2. Główne części to:
1. Panel sterowania
2. Zamek drzwi
3. Moduł zasilania (UPM)
4. Bateria wewnętrzna (brak w modelach C)
5. Obszar komunikacyjny
6. Przełącznik wejściowy
7. Odłącznik baterii
8. Przełącznik bypassu serwisowego
(opcjonalny)
.
NIEBEZPIECZEŃSTWO
W tej jednostce UPS występują napięcia o wartościach zagrażających życiu.
Prace wewnątrz jednostki UPS może wykonywupoważniony technik serwisu firmy Eaton
lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton. Wewnątrz jednostki UPS
nie ma żadnych elementów nadających się do serwisowania przez użytkownika.
W celu uzyskania kompletnych instrukcji bezpieczeństwa proszę odnieść się do instrukcji
obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton.
UPS musi być zamontowany zgodnie z zaleceniami zawartymi w instrukcji obsługi i montażu
systemu UPS 91PS/93PS 8-40 kW firmy Eaton.
Wykonaj poniższe czynności, aby zamontować UPS:
114
PL
1. Utwórz plan montażu systemu UPS.
2. Przygotuj miejsce montażu systemu UPS.
3. Sprawdź i rozpakuj szafę UPS.
4. Rozładuj szafę UPS i zamontuj ją, a następnie podłącz okablowanie.
5. Wypełnij listę kontrolną przy instalacji.
6. Upoważniony personel serwisu powinien przeprowadzić wstępną kontrolę i uruchomienie.
UWAGA: Kontrole przy uruchomieniu i eksploatacji muszą być wykonywane przez
upoważnionego technika serwisu firmy Eaton lub wykwalifikowany personel serwisowy z
autoryzacją firmy Eaton. W innym wypadku zostaną unieważnione warunki gwarancji.
Przed przystąpieniem do montażu systemu UPS należy przeczytać i zrozumieć instrukcje, które
odnoszą się do montowanego systemu. Do utworzenia logicznego planu instalacji systemu
należy wykorzystać dostarczone procedury oraz rysunki.
Aby zapewnić maksymalną sprawność systemu UPS, parametry środowiskowe miejsca
montażu muszą być zgodne z wartościami podanymi w instrukcji obsługi i montażu systemu
UPS 91PS/93PS 8-40 kW firmy Eaton.
Środowisko montażu musi spełniać wymagania dotyczące masy i rozmiaru UPS zawarte w
tabelach 2 i 3.
Wymiary systemu UPS przedstawia rysunek 1. Należy zauważyć, że wymiar głębokości (750
mm) zawiera dławiki kablowe.
Tabela 2. Wartości ciężaru szafy UPS z opakowaniem kartonowym
Model C 8-20 kW
(Ilustracja 1,
rysunek A)
Rama 15/20 kW*
(Ilustracja 1,
rysunek B)
Rama 30/40 kW*
(Ilustracja 1,
rysunek C)
Ciężar wysyłkowy
98 kg
293 kg
558 kg
Ciężar po montażu
86 kg
280 kg
532 kg
Obciążenie podłoża
310 kg/m
2
1107 kg/m
2
1478 kg/m
2
* Wszystkie modele są wyposażone w maksymalną liczbę baterii wewnętrznych.
W szafach UPS zastosowano układ wymuszonego chłodzenia powietrzem w celu kontrolowania
temperatury podzespołów wewnętrznych. Wloty powietrza standardowo znajdują się z przodu
szafy, a wyloty z tyłu. Patrz rysunek 3. W celu uzyskania poprawnego obiegu powietrza, z
przodu i z tyłu każdej szafy musi być wystarczająca ilość miejsca. Upewnić się, że temperatura
powietrza chłodzącego wchodzącego do jednostki UPS nie przekracza +40 °C. W celu
zapewnienia wymogów wentylacji należy odnieść się do instrukcji obsługi i montażu systemu
UPS 91PS/93PS 8-40 kW firmy Eaton.
115
PL
Tabela 3. Minimalna ilość wolnego miejsca dookoła szafy UPS
Rama 15/20 kW*
(Ilustracja 1,
rysunki A i B)
Rama 30/40 kW*
(Ilustracja 1,
rysunek C)
Nad szafą
500 mm
500 mm
Przed szafą
500 mm
650 mm
Za szafą
150 mm
250 mm
Z boku szafy
0 mm
0 mm
Zalecana temperatura i wilgotność robocza otoczenia dla systemu UPS przedstawiają rysunki
4.1 i 4.2. Aby uzyskać długą żywotność baterii VRLA zalecane jest utrzymywanie temperatury
otoczenia w zakresie od +20 °C do +25 °C.
Tabela 4. Minimalne parametry kabli wielyłowych i bezpieczników dla prostownika i wejścia bypassu
oraz wyjściowych przewodów systemu UPS (wejście trójfazowe, wyjście trójfazowe)
Moc znamionowa systemu
UPS 93PS (kW)
8
10
15
20
30
40
Kabel [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Bezpiecznik prostownika [A]
20
20
32
40
63
80
Bezpiecznik układu bypassu
[A]
20
20
32
40
63
80
Kabel PE [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Maksymalny przekrój
przewodu
Rama 20 kW i model C 20 kW: przewód drutowy 16 mm
2
,
standardowy przewód z tulejką: 10 mm
2
Rama 40kW: przewód drutowy 70 mm
2
, standardowy przewód z
tulejką: 50 mm
2
Tabela 5. Minimalne parametry kabli wielyłowych i bezpieczników dla prostownika i wejścia
bypassu oraz wyjściowych przewodów systemu UPS (wejście trójfazowe, wyjście
jednofazowe)
Moc znamionowa systemu
UPS 91PS (kW)
8
10
15
20
30
Przewód prostownika [mm
2
]
2,5
4
10
10
16
Bezpiecznik prostownika [A]
20
20
32
40
63
Obejście, przewód
wyjściowy [mm
2
]
10
16
25
35
70
Bezpiecznik układu bypassu
[A]
50
63
80
100
160
Kabel PE [mm
2
]
10
16
16
16
35
116
PL
Moc znamionowa systemu
UPS 91PS (kW)
8
10
15
20
30
Maksymalny przekrój
przewodu, rama 15 kW i
model C 15 kW
Prostownik: przewód drutowy 16 mm
2
, standardowy
przewód z tulejką: 10 mm
2
Obejście/wyjście: przewód drutowy 70 mm
2
,
standardowy przewód z tulejką: 50 mm
2
Maksymalny przekrój
przewodu, rama 30 kW
Prostownik: przewód drutowy 70 mm
2
, standardowy
przewód z tulejką: 50 mm
2
Obejście/wyjście: przewód drutowy 95 mm
2
,
standardowy przewód z tulejką: 95 mm
2
PRZESTROGA
Należy zapewnić, aby ewentualny prąd zwarcia na zaciskach wejściowych systemu UPS
był niższy lub równy warunkowemu prądowi zwarcia podanemu na tabliczce
znamionowej systemu UPS.
Tabela 6. Minimalne parametry kabli i bezpieczników przeznaczonych dla zewnętrznego zestawu
baterii
Moc znamionowa systemu
UPS (kW)
8
10
15
20
30
40
Linia dodatnia i ujemna
[mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Bezpiecznik baterii [A]
63
63
63
63
160
160
Kabel PE [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Maksymalny przekrój
przewodu
Rama 15/20 kW, model C i rama 30/40 kW z osobną baterią:
przewód drutowy: 25 mm
2
, standardowy przewód z tulejką: 16 mm
2
Rama 30/40 kW ze wspólna baterią: przewód drutowy: 90 mm
2
,
standardowy przewód z tulejką: 70 mm
2
Aby uzyskać więcej informacji o znamionowych i maksymalnych natężeniach dla znamionowej
mocy i napięcia, należy odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-
40 kW firmy Eaton.
W przypadku opcji oddzielnej baterii zewnętrznej dla obu zestawów baterii (szaf) są dostępne
oddzielne zaciski, patrz punkt 2.3.1.
UWAGA: Zewnętrzne zabezpieczenie nadprądowe nie jest wbudowane w tym urządzeniu, ale
jest wymagane w ramach przepisów. Wymagania dotyczące okablowania można znaleźć w
tabelach 4 i 5. Jeśli jest wymagany odłącznik na wyjściu z możliwością blokowania, jego
instalacja należy do obowiązków użytkownika.
Tabela 7. Momenty dokręcania zacisków kabli zasilających systemu UPS
Rama systemu UPS
Funkcja
Moment dokręcania Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: bateria +/-
3
117
PL
Rama systemu UPS
Funkcja
Moment dokręcania Nm
PE (uziemienie)
10 Nm dla przewodu 16-35 mm
2
6 Nm dla przewodu 4-10 mm
2
4 Nm dla przewodu 2,5 mm
2
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: bateria +/-
6
PE (uziemienie)
10 Nm dla przewodu 16-35 mm
2
6 Nm dla przewodu 4-10 mm
2
4 Nm dla przewodu 2,5 mm
2
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (uziemienie)
10 Nm dla przewodu 16-35 mm
2
6 Nm dla przewodu 4-10 mm
2
4 Nm dla przewodu 2,5 mm
2
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (uziemienie)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Czynność
Tak/Nie
Wszystkie materiały opakowaniowe i mocowania zostały zdjęte z każdej szafy.
Każda szafa w systemie UPS znajduje się w miejscu montażu.
Zamontowano zestaw montażowy/zestaw uziemienia szafy pomiędzy wszystkimi szafami,
które są razem skręcone.
Wszystkie kanały i kable są poprawnie poprowadzone do UPS i wszystkich szaf
pomocniczych.
Wszystkie kable zasilające mają właściwy przekrój poprzeczny i są prawidłowo
zakończone.
Przewody neutralne są zamontowane i podłączone do uziemienia zgodnie z wymogami.
Przewód uziemienia został prawidłowo zamontowany.
Przewody baterii są zakończone i podłączone do złączy baterii.
Przewód sygnału wyzwalania wzrostowego napięciowego baterii i przewód styku
pomocniczego z UPS należy podłączyć do odłącznika baterii.
Zamontowano linie odgałęźne sieci LAN.
Wszystkie połączenia LAN zostały wykonane.
System klimatyzacji został zainstalowany i działa prawidłowo.
Przestrzeń wokół zainstalowanego systemu UPS jest uporządkowana i oczyszczona z
kurzu (zalecane jest, aby system UPS został zainstalowany na poziomej posadzce,
odpowiedniej dla urządzeń komputerowych i elektronicznych).
Dookoła systemu UPS i innych szaf jest dostępna dostateczna ilość wolnego miejsca.
Okolice całego wyposażenia UPS są wyposażone w dostateczne oświetlenie.
118
PL
Czynność
Tak/Nie
Gniazdo zasilania 230 V (prąd przemienny) do celów serwisowych jest dostępne w
odległości do 7,5 m od sprzętu UPS.
Zdalny wyłącznik awaryjny (REPO) znajduje się w miejscu montażu, a jego okablowanie
jest zakończone wewnątrz szafy UPS.
Jeśli wykorzystywany jest wyłącznik EPO w konfiguracji NC, styki 1 i 2 EPO muszą
zostać połączone łącznikiem.
(OPCJA) Przekaźniki alarmowe i wyjścia sygnałowe zostały właściwie podłączone.
(OPCJA) Zdalny odłącznik baterii znajduje się w miejscu montażu, a jego okablowanie
jest zakończone wewnątrz szafy UPS i szafy baterii.
(OPCJA) Akcesoria znajdują się w miejscach montażu, a ich okablowanie jest
zakończone wewnątrz szafy UPS.
Upoważniony technik serwisu firmy Eaton lub wykwalifikowany technik serwisowy z
autoryzacją firmy Eaton przeprowadzili rozruch i kontrolę eksploatacji.
Rozpakowanie i wyładunek jednostki UPS przedstawiają rysunki 9.1 - 9.8.
Przed rozpoczęciem rozpakowania i rozładunku systemu UPS, należy sprawdzić wskaźniki
TipNTell i DropNTell na powierzchni opakowania. Jeśli urządzenie zostało prawidłowo
przetransportowane w pozycji pionowej, wskaźniki powinny pozostać nienaruszone. Jeśli
strzałka wskaźnika TipNTell zrobiła się cała niebieska lub grot(y) strzałki wskaźnika DropNTell
są czarne, należy skontaktować się z odpowiednimi osobami, aby zgłosić nieprawidłowy
transport.
W celach związanych z transportem szafa UPS jest przymocowana śrubami do drewnianej
palety. Przed rozładowaniem szafy z palety, należy użyć podnośnika widłowego lub innego
urządzenia transportowego do przeniesienia urządzenia do miejsca montażu.
OSTRZEŻENIE
Szafa UPS jest ciężka. Nieprzestrzeganie instrukcji dotyczących rozpakowywania może być
przyczyną przewrócenia szafy i poważnych obrażeń ciała.
Nie wolno przechylać szaf UPS więcej niż 10 stopni od pionu. W przeciwnym razie może dojść
do przewrócenia szafy.
UWAGA: Po usunięciu wsporniw transportowych, jednostkę należy natychmiast usunąć z
palety.
Po zdemontowaniu wsporników transportowych i wkręceniu nóżek poziomujących, do
przenoszenia urządzenia nie należy używać podnośnika widłowego, gdy znajduje się nadal na
palecie. Należy pamiętać, że szafa UPS jest ciężka i ma przymocowane kółka w dolnej części.
W przypadku konieczności usunięcia szafy z pierwotnego miejsca instalacji i przeniesienia jej
na palecie do nowego, należy obniżyć nóżki poziomujące do momentu aż szafa nie będzie
opierać się na kółkach i zamontować wsporniki transportowe do szafy i palety.
Do obowiązków operatora należy instalacja okablowania, które umożliwi podłączenie UPS
do lokalnego źródła zasilania. Instalacja systemu UPS musi zostać wykonana przez
wykwalifikowanego elektryka. Upoważniony technik serwisu firmy Eaton lub
wykwalifikowany personel serwisowy z autoryzacją firmy Eaton może sprawdzić instalację,
wykonać wstępny rozruch UPS lub zamontować dodatkową szafę baterii.
119
PL
Montaż jednostki UPS przedstawiają rysunki 10.1-10.5.
Zaciski kabla zasilającego UPS przedstawiają ilustracje 6.1 (rama 91PS 15 kW), 6.2 (rama
93PS 20 kW), 7.1 (rama 91PS 30 kW ze wspólną baterią), 7.2 (rama 91PS 30 kW z opc
osobnej baterii), 8.1 (rama 93PS 40 kW ze wspólną baterią) i 8.2 (rama 93PS 40 kW z opc
osobnej baterii).
X1
Wejście prostownika
X4/-
Zewnętrzna bateria -
X2
Wejście bypassu
TB20
Wyłącznik baterii
zewnętrznej
X3
Wyjście UPS
TB21
Wyłącznik baterii
zewnętrznej
X4/+
Zewnętrzna bateria +
PE
Uziemienie ochronne
UPM2
(osobna bateria)
Zaciski komunikacyjne UPS przedstawiają ilustracje 5.1 i 5.2. Zaciski mają oznaczenia, jak
poniżej:
1. TB11, nieużywany
2. TB10, nieużywany
3. TB9, nieużywany
4. TB8, zewnętrzne
przyłącze CAN
5. TB7, zewnętrzny CAN
6. TB6, magistrala
komunikacji
łańcuchowej
7. USB1, host USB
(podłączenie akcesoriów)
8. USB2, urządzenie USB
(połączenie z komputerem
PC)
9. MiniSlot 1
10. TB1, wejście sygnałowe 1-5
11. TB2, nieużywany
12. TB3, nieużywany
13. Szeregowy port COM RS-
232
14. MiniSlot 2
15. TB4, EPO
16. TB5, wyjście przekaźnika
W przypadku instalacji systemu baterii dostarczonego przez klienta należy zamontować system
zgodnie z instrukcjami producenta baterii i systemu baterii oraz wszystkich stosownych
krajowych przepisów i zarządzeń.
W celu uzyskania danych technicznych baterii proszę odnieść się do instrukcji obsługi i montażu
systemu UPS 91PS/93PS 8-40 kW firmy Eaton.
Jednostki UPS 91PS/93PS 8-40 kW zawsze są wyposażone w odłącznik wewnętrznej baterii,
który dotyczy wyłącznie baterii wewnętrznych UPS (z wyjątkiem modeli C, w których odłącznik
wewnętrznej baterii może zostać użyty dla baterii zewnętrznych). Kluczowym elementem
zewnętrznej szafy lub regału baterii jest odłącznik baterii zewnętrznych. Urządzenia te mus
być w niego wyposażone. W przypadku odłącznika baterii zewnętrznej, znaczenie ma również
okablowanie sygnałowe.
Odłączniki baterii wewnętrznych i zewnętrznych mogą zostać wyzwolone (wyłączone) poprzez
podłączenie napięcia do cewki wyzwalacza wzrostowego. Cewki wyzwalacza wzrostowego
odłączników baterii zewnętrznych są podłączane do napięcia (sterowane) za pośrednictwem
złączy TB20 i TB21 (złącze TB21 jest dostępne wyłącznie w przypadku systemu UPS o mocy 8-
40 kW w konfiguracji z osobną baterią). Standardowe napięcie cewki wyzwalacza wzrostowego
wynosi 24 V prądu stałego.
Okablowanie wyłącznika samoczynnego baterii przedstawia rysunek 11. Części to:
A
Odłącznik baterii zewnętrznej
3
Styk 3, styk AUX
1
Styk 1, cewka wyzwalacza
wzrostowego +
4
Styk 4, styk powrotny AUX
2
Styk 2, cewka wyzwalacza
wzrostowego -
120
PL
Instrukcje na temat sposobu instalacji zewnętrznej szafy baterii i jej okablowania zasilającego
znajdują się w instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton oraz
instrukcji obsługi zewnętrznej szafy baterii. Zewnętrzną szafę baterii / system baterii dostarczany
przez użytkownika należy uziem za pomocą zacisku ochronnego PE 17.
Wyłącznik EPO jest podłączony do górnego panelu przedniego systemu UPS za pośrednictwem
złącza EPO. Złącza przełącznika EPO przedstawia rysunek 12.
W celu uzyskania informacji dotyczących montażu złączy interfejsu proszę odnieść się do
instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton.
Jeden styk przekaźnika ogólnego zastosowania należy do wyposażenia standardowego UPS.
Jest także dostępny styk alarmu. Konfiguracje przekaźnika wyjściowego przedstawia rysunek
13.
Można użyć styku normalnie otwartego lub normalnie zamkniętego. Jeśli stan styku zmieni się
ze stanu określonego jako normalny, jest generowany sygnał. Można podłączyć ten styk do
sprzętu w instalacji (jak np. oświetlenie czy dzwonek alarmowy), aby zasygnalizować stan
alarmu UPS.
UWAGA: Maksymalna obcżalność styków wynosi 30 V (prąd przemienny) (RMS) i 30 V (prąd
stały) przy prądzie 5 A.
W celu uzyskania informacji dotyczących okablowania równoległych systemów UPS 91PS/93PS
proszę odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy
Eaton.
121
IT
1
PERICOLO
Istruzioni importanti per la sicurezza!
Conservare le presenti istruzioni!
Il presente documento contiene importanti istruzioni sulla sicurezza e brevi istruzioni per
l'ispezione dell'UPS alla consegna nonché per l'installazione dell'UPS. La presente guida
rapida è destinata esclusivamente a essere usata come elenco di controllo per
l'installazione in loco.
Il presente documento è destinato a professionisti esperti che pianificano ed eseguono
l’installazione dell’UPS.
PERICOLO
Prima di iniziare a lavorare sull’UPS, leggere le istruzioni di installazione complete fornite
nel Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS.
Le istruzioni complete sono disponibili per il download dal sito
www.eaton.com/91psand93ps.
Le operazioni all’interno dell’UPS devono essere effettuate da un tecnico autorizzato
dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e
autorizzato da Eaton. All'interno dell'UPS non sono presenti parti sostituibili o riparabili
dall'utente.
L'unità UPS funziona con alimentazione da rete elettrica, batteria o alimentazione di
bypass. Contiene componenti sottoposti a correnti e tensioni elevate. Per una corretta
installazione dell'involucro, è necessaria una messa a terra adeguata e una classificazione
IP20 contro scosse elettriche e corpi estranei. Nondimeno, l'unità UPS è un sistema di
alimentazione sofisticato e solo il personale qualificato è autorizzato a effettuare
l'installazione e gli interventi di manutenzione su di esso.
PERICOLO
In questo UPS sono presenti organi con tensioni letali.
Le batterie costituiscono rischio di scosse elettriche o ustioni causate da elevata corrente
di cortocircuito. Osservare le precauzioni.
Le batterie potrebbero contenere TENSIONI ELEVATE e SOSTANZE CORROSIVE,
TOSSICHE ed ESPLOSIVE. A causa della stringa della batteria, sulle prese di uscita può
essere presente alta tensione anche quando l’alimentazione CA non è collegata all’UPS.
Leggere le istruzioni per lo spegnimento nel Manuale utente e guida all'installazione.
ATTENZIONE
Questo UPS è alimentato dalla propria fonte di energia (batterie). I morsetti di uscita
potrebbero essere sotto tensione anche quando l'UPS è disconnesso da una sorgente di
CA. Per ridurre il rischio di incendi o scosse elettriche, installare l'UPS in un ambiente
chiuso privo di elementi contaminanti conduttivi, con temperatura e umidità controllate.
Non sovrapporre l’armadio modello C dell’UPS 91PS/93PS su altri armadi simili. Non
sovrapporre niente sopra l’armadio dell’UPS 91PS/93PS. Se l’armadio modello C
dell’UPS 91PS/93PS è installato su uno scaffale, usare i supporti necessari per evitare
che l’UPS si ribalti o cada.
122
IT
ATTENZIONE
La temperatura ambiente non deve superare i 40 °C. Non utilizzare l'UPS in prossimità di
acqua o eccessiva umidità (massimo 95%). Il sistema non è destinato all'uso in ambienti
esterni.
Prima di iniziare qualunque intervento di installazione o assistenza, verificare che tutte le
fonti di alimentazione elettrica CA e CC siano disconnesse. L'alimentazione elettrica può
provenire da diverse fonti. Verificare inoltre la continuità della connessione a terra / e dei
conduttori PE.
In un sistema parallelo, i morsetti di uscita potrebbero essere sotto tensione anche
quando l'UPS è spento.
Pericolo per presenza di energia elettrica. Per evitare lesioni, non tentare di alterare
alcun cablaggio o connettore delle batterie.
IMPORTANTE: Assicurarsi di disconnettere tutte le stringhe delle batterie prima
dell'installazione.
AVVISO
Solo il personale addetto all'assistenza qualificato e competente in materia di batterie e
precauzioni necessarie è autorizzato a effettuare interventi di installazione o assistenza
sulle batterie. Gli interventi di installazione e manutenzione sulle batterie sono lavori su
linee attive e richiedono l’uso di strumenti per interventi con tensione attiva. Tenere il
personale non autorizzato lontano dalle batterie.
Prima di installare o sostituire le batterie, considerare tutte le indicazioni di allarme e
attenzione e le note relative alla corretta manipolazione. Non disconnettere le batterie
con l'unità UPS in modalità batteria.
Verificare che le batterie sostitutive siano dello stesso numero e tipo delle batterie
installate in origine nell'UPS. Consultare le istruzioni più accurate presenti sull'UPS.
Prima di connettere o disconnettere i terminali della batteria, scollegare la fonte di
alimentazione di ricarica aprendo il corrispondente interruttore di circuito.
Controllare che la batteria non sia stata inavvertitamente connessa a terra. Se lo è,
rimuovere la sorgente di terra. Il contatto di una parte di una batteria con messa a terra
può causare rischio di scosse elettriche.
Smaltire le batterie in conformità alle disposizioni locali in materia di smaltimento dei
rifiuti.
Non smaltire le batterie nel fuoco. Se esposte al fuoco, le batterie possono esplodere.
Per ridurre il rischio di incendio, collegare solo a un circuito dotato di interruttore di
circuito con corrente nominale massima di ingresso in conformità ai regolamenti locali e
nazionali per impianti elettrici.
Per garantire un adeguato flusso d'aria di raffreddamento e proteggere il personale dalle
tensioni elettriche pericolose presenti all'interno dell'unità, mantenere lo sportello
dell'UPS chiuso e i pannelli anteriori installati.
Non installare o utilizzare il sistema di UPS in prossimità di fonti di calore a gas o
elettriche.
Mantenere l'ambiente di lavoro entro i parametri stabiliti nel presente documento.
Mantenere l'area circostante l'UPS ordinata, pulita e priva di umidità in eccesso.
Osservare tutte le indicazioni di PERICOLO, AVVISO e ATTENZIONE apposte all'interno
e all'esterno delle apparecchiature.
123
IT
2
Il gruppo di continuità (UPS, uninterruptible power supply) Eaton® 91PS/93PS è un
sistema online monofase (91PS) o trifase (93PS), a stato solido, a doppia conversione,
senza trasformatore, per servizio continuo. Fornisce alimentazione CA condizionata e
continua ai carichi critici proteggendoli in caso di interruzioni di corrente. Le potenze
nominali di uscita dell'unità Eaton 91PS/93PS si basano sui moduli di continuità di
alimentazione (UPM) con potenza nominale di 15 kW o 20 kW.
Il 91PS/93PS è disponibile anche come modello C costituito dalla parte elettrica del telaio
da 15/20 kW dell’UPS 91PS/93PS senza vano batterie.
Tabella 1. Valori nominali dell'armadio UPS
Telaio UPS
Immagine
(Illustrazione 1)
Numero di UPM
Valori nominali
91PS 15 kW
A e B
1
8, 10, 15 kW
91PS 30 kW
C
1 o 2
8, 10, 15, 20, 30 kW
93PS 20 kW
A e B
1
8, 10, 15 o 20 kW
93PS 40 kW
C
1 o 2
8, 10, 15, 20, 30 o 40
kW
I componenti principali dell’UPS 91PS/93PS da 8-40 kW sono mostrati nell’illustrazione 2.
Le parti principali sono le seguenti:
1. Pannello di controllo
2. Blocco sportello
3. Modulo di alimentazione (UPM)
4. Batteria interna (non nei modelli C)
5. Area comunicazioni
6. Interruttore di ingresso
7. Interruttore di esclusione batteria
8. Interruttore di bypass per manutenzione
(opzionale)
.
PERICOLO
In questo UPS sono presenti organi con tensioni letali.
Le operazioni all’interno dell’UPS devono essere effettuate da un tecnico autorizzato
dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e
autorizzato da Eaton. All'interno dell'UPS non sono presenti parti sostituibili o riparabili
dall'utente.
Per istruzioni complete sulla sicurezza, vedere il Manuale utente e guida all'installazione
dell’UPS da 8-40 kW Eaton 91PS/93PS.
L’UPS deve essere installato in conformità alle raccomandazioni contenute nel Manuale
utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS.
Utilizzare la seguente procedura di base per installare l'UPS:
124
IT
1. Creare un piano di installazione per il sistema UPS.
2. Preparate il sito per il sistema UPS.
3. Ispezione e disimballaggio degli armadi dell'UPS.
4. Scaricare e installare l'armadio dell'UPS, quindi cablare il sistema.
5. Completare l'elenco di controllo di installazione.
6. Chiedere al personale di assistenza autorizzato di eseguire controlli operativi preliminari
e avviare il sistema.
NOTA: Le verifiche di avvio e in fase operativa devono essere eseguite esclusivamente da
un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza
qualificato e autorizzato da Eaton, altrimenti la garanzia verrà invalidata.
Prima di installare il sistema UPS, leggere e comprendere il modo in cui le presenti
istruzioni possono essere applicate al sistema da installare. Seguire le procedure e le
illustrazioni fornite per creare un piano logico per l'installazione del sistema.
Per il funzionamento del sistema UPS alla massima efficienza, il luogo di installazione
deve soddisfare i parametri ambientali indicati nel Manuale utente e guida all'installazione
dell’UPS da 8-40 kW Eaton 91PS/93PS.
L’ambiente di installazione deve soddisfare i requisiti di peso e dimensioni dell’UPS forniti
nelle Tabelle 2 e 3.
Le dimensioni dell’armadio dell’UPS sono indicate nell’illustrazione 1. Notare che la quota
della profondità (750 mm) include i passacavi.
Tabella 2. Peso dell'armadio dell'UPS con imballaggio in cartone
Modello C 8-20 kW
(Illustrazione 1,
immagine A)
Telaio da 15/20 kW*
(Illustrazione 1,
immagine B)
Telaio da 30/40 kW*
(Illustrazione 1,
immagine C)
Peso di spedizione
98 kg
293 kg
558 kg
Peso dopo
l'installazione
86 kg
280 kg
532 kg
Carico sul pavimento
310 kg/m
2
1.107 kg/m
2
1.478 kg/m
2
* Le batterie interne massime sono incluse in tutti i modelli.
Gli armadi per UPS utilizzano il raffreddamento forzato dell'aria per regolare la temperatura
dei componenti interni. Per impostazione predefinita, gli ingressi dell'aria si trovano sulla
parte anteriore dell'armadio e le uscite sulla parte posteriore, vedere illustrazione 3.
Lasciare uno spazio idoneo davanti e dietro a ciascun armadio per la corretta circolazione
dell'aria. Verificare che l'aria di raffreddamento in ingresso nell'UPS non superi +40 °C. Per
i requisiti di ventilazione, vedere il Manuale utente e guida all'installazione dell’UPS da 8-
40 kW Eaton 91PS/93PS.
125
IT
Tabella 3. Distanze minime dell'armadio UPS
Telaio da 15/20 kW
(Illustrazione 1,
immagini A e B)
Telaio da 30/40 kW
(Illustrazione 1,
immagine C)
Dalla parte superiore
dell'armadio
500 mm
500 mm
Dalla parte anteriore
dell'armadio
500 mm
650 mm
Dalla parte posteriore
dell'armadio
150 mm
250 mm
Dalla parte laterale
dell'armadio
0 mm
0 mm
La temperatura ambiente e l’umidità raccomandate per il funzionamento del sistema UPS
sono mostrate nelle illustrazioni 4.1 e 4.2. Si consiglia una temperatura ambiente
compresa fra +20 °C e +25 °C per ottenere una lunga durata delle batterie VRLA.
Tabella 4. Dimensioni minime raccomandate per cavo multiconduttore e fusibili per cavi di ingresso di
bypass e raddrizzatore e cavi di uscita UPS (ingresso trifase, uscita trifase)
Valori nominali dell’UPS 93PS (kW)
8
10
15
20
30
40
Cavo [mm
2
]
4*2,5
4*4
4*10
4*10
4*16
4*25
Fusibile del raddrizzatore [A]
20
20
32
40
63
80
Fusibile di bypass [A]
20
20
32
40
63
80
Cavo PE [mm
2
]
1*6
1*6
1*10
1*10
1*16
1*16
Sezione massima del conduttore
Telaio da 20 kW e modello C da 20 kW: cavo pieno da
16 mm
2
, cavo intrecciato con boccola: 10 mm
2
Telaio da 40kW: cavo pieno da 70 mm
2
, cavo intrecciato
con boccola: 50 mm
2
Tabella 5. Dimensioni minime raccomandate per cavo multiconduttore e fusibili per cavi di ingresso di
bypass e raddrizzatore e cavi di uscita UPS (ingresso trifase, uscita monofase)
Valori nominali dell’UPS 91PS (kW)
8
10
15
20
30
Cavo raddrizzatore [mm
2
]*
2,5
4
10
10
16
Fusibile del raddrizzatore [A]
20
20
32
40
63
Bypass, cavo di uscita [mm
2
]
10
16
25
35
70
Fusibile di bypass [A]
50
63
80
100
160
Cavo PE [mm
2
]
10
16
16
16
35
126
IT
Valori nominali dell’UPS 91PS (kW)
8
10
15
20
30
Sezione massima conduttore, telaio
15 kW e modello 15 kW C
Raddrizzatore: cavo pieno da 16 mm
2
, cavo
intrecciato con boccola: 10 mm
2
Bypass/uscita: cavo pieno da 70 mm
2
, cavo
intrecciato con boccola: 50 mm
2
Sezione massima del conduttore,
telaio da 30 kW
Raddrizzatore: cavo pieno da 70 mm
2
, cavo
intrecciato con boccola: 50 mm
2
Bypass/uscita: cavo pieno da 95 mm
2
, cavo
intrecciato con boccola: 95 mm
2
AVVISO
Assicurarsi che la corrente di cortocircuito potenziale ai terminali di ingresso dell’UPS sia
uguale o inferiore alla corrente di cortocircuito condizionale dichiarata sulla targhetta
nominale dell’UPS.
Tabella 6. Dimensioni minime raccomandate di cavi e fusibili per il banco esterno della batteria
Valori nominali dell’UPS
(kW)
8
10
15
20
30
40
Linea pos. e neg. [mm
2
]
1*16
1*16
1*16
1*16
1*35
1*35
Fusibile batteria [A]
63
63
63
63
160
160
Cavo PE [mm
2
]
1*16
1*16
1*16
1*16
1*16
1*16
Sezione massima del
conduttore
Telaio da 15/20 kW, modello C e telaio da 30/40 kW con batteria
separata: cavo pieno: 25 mm
2
, cavo intrecciato con boccola:
16 mm
2
Telaio da 30/40 kW con batteria comune: cavo pieno: 90 mm
2
, cavo
intrecciato con boccola: 70 mm
2
Per informazioni sulle correnti nominali e massime relative ai valori di potenza e tensione
nominali, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton
91PS/93PS.
Per un’opzione batteria separata esterna, vi sono morsetti separati per entrambi i banchi
della batteria (armadi), vedere la sezione 2.3.1.
NOTA: La protezione contro la sovracorrente esterna non è fornita dal prodotto, ma è
richiesta dalle normative. Per i requisiti di cablaggio, fare riferimento alle tabelle 4 e 5. Se è
necessario un sezionatore bloccabile di uscita, deve essere fornito dall'utente.
127
IT
Tabella 7. Coppie dei morsetti per i cavi di alimentazione dell'UPS
Telaio UPS
Funzione
Coppia di serraggio Nm
93PS 20 kW
X1, X2, X3: L1, L2, L3, N
1.6
X4: batteria +/-
3
PE (terra)
10 Nm per cavo da 16-35 mm
2
6 Nm per cavo da 4-10 mm
2
4 Nm per cavo da 2,5 mm
2
93PS 40 kW
X1, X2, X3: L1, L2, L3, N
6
X4: batteria +/-
6
PE (terra)
10 Nm per cavo da 16-35 mm
2
6 Nm per cavo da 4-10 mm
2
4 Nm per cavo da 2,5 mm
2
91PS 15 kW
X1
1.6
X2, X3
7
X4
3
PE (terra)
10 Nm per cavo da 16-35 mm
2
6 Nm per cavo da 4-10 mm
2
4 Nm per cavo da 2,5 mm
2
91PS 30 kW
X1
6
X2, X3
17
X4
6
PE (terra)
7 Nm (X1, X2, X3)
3.5 Nm (X4)
Azione
Sì/No
Tutti i materiali dell'imballaggio e i sostegni sono stati rimossi da ciascun armadio.
Ciascun armadio del sistema UPS si trova nella posizione di installazione.
Un kit di messa a terra dell'armadio / un kit di montaggio è installato fra gli armadi
imbullonati fra loro.
Tutti i condotti e i cavi sono stati disposti correttamente nell'UPS e negli armadi
accessori.
Tutti i cavi di alimentazione sono correttamente dimensionati e cablati.
I conduttori neutri sono installati e collegati a massa in conformità ai requisiti.
Il conduttore di massa è correttamente installato.
I cavi della batteria sono terminati e connessi ai connettori della batteria.
Il cablaggio del segnale di contatto Aux e di attivazione dello shunt della batteria è
collegato dall'UPS all'interruttore della batteria.
I punti di collegamento della LAN sono installati.
Tutte le connessioni LAN sono completate.
L'apparecchio di climatizzazione è installato e funziona correttamente.
L'area attorno al sistema UPS installato è pulita e priva di polvere (si raccomanda di
installare su una superficie piana adeguata per computer o apparecchiature
elettroniche).
128
IT
Azione
Sì/No
È presente un adeguato spazio di lavoro tra l'UPS e altri armadi.
È fornita un'illuminazione adeguata intorno a tutte le apparecchiature dell'UPS.
Una presa di servizio a 230 VCA si trova entro 7,5 metri dalle apparecchiature dell'UPS.
Il dispositivo REPO (Remote Emergency Power-off) è montato nella posizione di
installazione e il relativo cablaggio è terminato all'interno dell'armadio dell'UPS.
Se è utilizzato un dispositivo EPO nella configurazione NC, fra i pin 1 e 2 è installato un
ponticello sull'EPO.
(OPZIONALE) I relè di allarme e le uscite dei segnali sono collegate adeguatamente.
(OPZIONALE) Un dispositivo di scollegamento remoto della batteria è montato nella
posizione di installazione e il relativo cablaggio è terminato all'interno dell'armadio per
UPS e batterie.
(OPZIONALE) Gli accessori sono montati nelle posizioni di installazione e il cablaggio è
terminato all'interno dell'armadio dell'UPS.
I controlli per l'avvio e il funzionamento sono stati eseguiti da un tecnico autorizzato
dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e
autorizzato da Eaton.
Le operazioni di disimballaggio e scarico dell'UPS sono mostrate nelle illustrazioni 9.1 -
9.8.
Prima di iniziare a disimballare e scaricare l’UPS, controllare gli indicatori di
danneggiamento TipNTell / DropNTell sulla superficie dell’imballaggio. Se
l'apparecchiatura è stata trasportata correttamente in posizione verticale, gli indicatori
devono essere intatti. Se la freccia dell’indicatore TipNTell è diventata interamente blu o le
teste delle frecce per l’indicatore DropNTell sono nere, contattare le parti incaricate per
segnalare un trasporto errato.
L’armadio dell’UPS è imbullonato su un pallet di legno per il trasporto. Prima di scaricare
l'armadio dal pallet, utilizzare un carrello elevatore a forca o altri dispositivi di
movimentazione merci per spostare l'armadio nell'area di installazione.
ATTENZIONE
L'armadio dell'UPS è pesante. Se non si osservano rigorosamente le istruzioni per il
disimballaggio, l'armadio potrebbe ribaltarsi e causare gravi lesioni.
Non inclinare l'armadio dell'UPS di oltre 10° in verticale per evitare che si ribalti.
NOTA: Dopo aver rimosso le staffe di trasporto, spostare immediatamente l'unità dal
pallet.
Dopo aver rimosso le staffe di trasporto e aver fatto ritrarre i piedini regolabili, non usare
un carrello elevatore a forche per spostare l'unità quando è ancora sul pallet. Notare che
l'armadio UPS è pesante ed è dotato di ruote orientabili nella parte inferiore.
Se si rimuove l'armadio dalla posizione di installazione originale per trasferirlo in una
nuova posizione utilizzando un pallet, far rientrare i piedini regolabili finché l'armadio non
appoggia sulle ruote e collegare le staffe di trasporto all’armadio e al pallet.
129
IT
L’operatore deve fornire il cablaggio per collegare l'UPS alla fonte di alimentazione locale.
L’installazione dell’UPS deve essere effettuata da un elettricista del posto qualificato.
L'ispezione dell'installazione e l'avvio iniziale dell'UPS, nonché l'installazione di un armadio
della batteria supplementare devono essere eseguiti da un tecnico autorizzato
dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e
autorizzato da Eaton.
L’installazione dell'UPS è mostrata nelle illustrazioni 10.1-10.5.
I terminali del cavo di alimentazione dell'UPS sono illustrati nella figura 6.1 (telaio da 15
kW 91PS), 6.2 (telaio da 20 kW 93PS), 7.1 (telaio da 30kW 91PS con batteria comune),
7.2 (telaio da 30kW 91PS con opzione batteria separata), 8.1 (telaio da 40kW 93PS con
batteria comune) e 8.2 (telaio da 40kW 93PS con opzione batteria separata).
X1
Ingresso raddrizzatore
X4/-
Batteria esterna -
X2
Ingresso bypass
TB20
Esclusione batteria esterna
X3
Uscita UPS
TB21
Esclusione batteria esterna
X4/+
Batteria esterna +
PE
Terra di protezione
UPM2
(batteria separata)
I terminali di comunicazione dell'UPS sono mostrati nelle illustrazioni 5.1 e 5.2. I terminali
sono i seguenti:
1. TB11, non utilizzato
2. TB10, non utilizzato
3. TB9, non utilizzato
4. TB8, terminazione
esterna CAN
5. TB7, CAN esterna
6. TB6, bus pull chain
7. USB1, host USB
(connessione agli
accessori)
8. USB2, dispositivo USB
(connessione al computer)
9. Mini-Slot 1
10. TB1, ingresso segnale 1-5
11. TB2, non utilizzato
12. TB3, non utilizzato
13. Porta COM in serie RS-
232
14. Mini-Slot 2
15. TB4, EPO
16. TB5, uscita relè
Se si installa un sistema di batterie fornito dal cliente, è necessario operare
conformemente alle istruzioni del produttore della batteria e del sistema di batterie e a tutti
i codici e le normative nazionali applicabili.
Per le specifiche della batteria, vedere il Manuale utente e guida all'installazione dell’UPS
da 8-40 kW Eaton 91PS/93PS.
Le unità dell’UPS 91PS/93PS 8-40 kW sono sempre dotate di un interruttore di esclusione
batteria interno che ha effetto solo sulle batterie interne dell’UPS (tranne per i modelli C in
cui l’interruttore di esclusione batteria interno può essere usato per le batterie esterne).
L'interruttore esterno di esclusione delle batterie è una parte cruciale dell'armadio o del
rack portabatterie esterno e deve essere incluso in tale componente. Con l’interruttore
esterno di esclusione della batteria, il cablaggio del segnale è importante.
Per far scattare (disattivare) gli interruttori di esclusione batteria interni ed esterni è
possibile eccitare la bobina di attivazione shunt. Le bobine di attivazione shunt di
interruttori di esclusione batteria esterni sono alimentate (controllate) attraverso connettori
TB20 e TB21 (TB21 disponibile solo nell’UPS da 8-40 kW con configurazione della batteria
separata). La tensione predefinita di innesco della bobina di attivazione shunt è 24 VCC.
130
IT
Il cablaggio di esclusione batteria è mostrato nell’illustrazione 11. Le parti sono le seguenti:
A
Interruttore di esclusione
batteria esterno
3
Pin 3, contatto AUX
1
Pin 1, bobina di attivazione
shunt +
4
Pin 4, ritorno contatto AUX
2
Pin 2, bobina di attivazione
shunt -
Per istruzioni su come installare l’armadio batteria esterno e il cablaggio di alimentazione
della batteria, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton
91PS/93PS e il manuale di istruzioni fornito con l’armadio della batteria esterno. Collegare
a terra l’armadio batteria esterno / sistema di batterie fornito dal cliente al morsetto PE 17.
L'interruttore EPO è connesso al connettore dedicato EPO posto sul pannello frontale
superiore dell'UPS. Le connessioni dell’interruttore EPO sono mostrate nell’illustrazione
12.
Per informazioni sulle connessioni dell’interfaccia di installazione, vedere il Manuale utente
e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS.
Un contatto relè per uso generico è fornito sull'UPS come caratteristica standard. È
disponibile anche un contatto di allarme. Le configurazioni del relè di uscita sono mostrate
nell’illustrazione 13.
È possibile utilizzare un contatto normalmente chiuso o normalmente aperto. Se lo stato
del segnale cambia dallo stato specificato come normale, viene emesso un segnale.
Questo contatto può essere collegato all'apparecchiatura della struttura (ad esempio una
spia o un allarme) per sapere quando sull'UPS si attiva un allarme.
NOTA: I contatti azionati non devono superare 30 VCA (RMS) e 30 VCC a massimo 5 A.
Per informazioni sul cablaggio dei sistemi UPS 91PS/93PS paralleli, vedere il Manuale
utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS.
131
132
133
134
135
Eaton Power Quality Oy
Koskelontie 13
FI-02920 Espoo
Finland
www.eaton.eu
Copyright © 2018 Eaton Corporation plc. All rights reserved. Unauthorized copying and lending are prohibited.
ARTWORK, SOFTWARE DOWNLOAD INSERT
P-164000532
001
11-DEC-2015M. Carnes
ECO-094337
Release
1 1
Eaton.com/downloads
Software
© 2015 Eaton. All rights reserved.
Literature code: IL152001EN November 2015
Part Number: P-164000532 Rev 001
Obrigado por
escolher uma UPS
Eaton. Incremente
a sua compra ao
fazer o download
do software de
gestão de energia
da Eaton
Thank you for choosing
an Eaton UPS. Enhance
your purchase by
downloading Eaton
power management
software
Gracias por elegir
un UPS de Eaton.
Descarga el software
de administración de
energía Eaton para
mejorar su compra
inmediatamente
Vielen Dank, dass Sie sich für eine
Eaton USV entschieden haben. Um
das volle Potential zu nutzen, laden
Sie die Eaton Power Management
Software herunter
Merci d’avoir choisi un
onduleur Eaton. Bénéficiez
de toutes ses performances
en téléchargeant le logiciel
de gestion d’énerg
ie Eaton
P-164000532_artwork.ai 11/3/15 2:05 PM

Transcripción de documentos

480 mm SAFETY AND INSTALLATION QUICK GUIDE 335 mm 750 mm 7 1 335 mm 750 mm 8 2 750 mm 1750 mm 1300 mm 9 3 10 4 11 5 12 6 13 645 mm 14 DOWNLOAD FULL USER’S AND INSTALLATION GUIDE AT WWW.EATON.COM/91PSAND93PS 93PS UPS Eaton Eaton 91PS/93PS 8-40 kW 5.1 16 15 ≤ 40 ºC A 91PS 15 kW 93PS 20 kW B 91PS 15 kW 93PS 20 kW C 91PS 30 kW 93PS 40 kW 1 9 14 5 6 ID REV2 Document P-164000576 1 3 5 7 -10 ºC 0 ºC 10 ºC 20 ºC 30 ºC 40 ºC 93PS 20 kW 4.1 8 4 0% % 3 1 20 % 40% 60% 80 % 100% 95 % X1 N L2 X2 N L2 X3 N L2 X4 L1 L3 L1 L3 L1 L3 + - 91PS 15 kW X1 4.2 L1 L2 L3 5 X2 X3 N L N L X4 + - 6 8 1 8 10 11 12 13 15 16 50 ºC 7 2 2 5.2 3 6 3 4 TB20 7 PE TB20 2 4 2 PE 6.1 6.2 91PS 30 kW 91PS 30 kW 1 X1 X2 X4/+ PE 4 X4/- 1 TB20 PE 93PS 40 kW 9.2 9.1 PE (X1,X2) TB20 7.1 10.2 N L X3 PE (X1,X2) TB21 11 1 9.5 10.1 2 X2 N L1 L2 L3 NC NC 10.3 5.1/5.2 12 1 <80° 9.6 X2 X4 / + 1 N L1 L2 L3 X4 / - 2 4 X3 X4 / - TB20 TB20 1 2 3 4 NO NO 9.4 X1 1 3 1 2 3 4 3 2 X1 3 4 7.2 N L1 L2 L3 N L1 L2 L3 2 A 9.3 93PS 40 kW N L1 L2 L3 X4 / + 3 TB21 PE 1 3 2 4 PE N L X3 2 A X2 X1 + X4 BLUE BEADS IN ARROW INDICATES CONTAINER WAS TIPPED OR MISHANDLED MADE IN U.S.A. L1 L2 L3 N L TB20 L1 L2 L3 N L N L1 L2 L3 NO NO 2 3 1 2 3 NC NC X3 2 TB21 1 PE PE 8.1 8.2 9.7 9.8 10.4 10.5 13 CONTENTS EN DE FR FI SV NO DA RU NL ES CS PL IT Safety and Installation Quick Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2 Schnellanleitung für Sicherheit und Installation . . . . . . . . . . . . . . . . . . . . . . . . . 12 Guide rapide de sécurité et d’installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Turvallisuus- ja asennuspikaopas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Snabbguide för säkerhet och installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Hurtigveiledning for sikkerhets or installasjon . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Hurtig sikkerheds- of installationsvejledning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Kpatkoe руководство по технике безопасности и установке . . . . . . . . . . 72 Verkorte handleidingvoor veiligheid en installatie. . . . . . . . . . . . . . . . . . . . . . . 82 Guía de seguridad y de instalación rápida. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Rychlá bezpečnostní a instalační příručka. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102 Skrócona instrukcja bezpieczeństwa i montażu . . . . . . . . . . . . . . . . . . . . . . . . 112 Guida rapida all’installazione e informazioni sulla sicurezza . . . . . . . . . . . . . 122 1 EN 1 DANGER Important safety instructions! Keep these instructions! This document provides important safety instructions and a short instruction for how to examine the UPS delivery and how to install the UPS. This quick guide is only meant to be used as an installation checklist on site. The intended audience of this document is experienced professionals who plan and do the installation of the UPS. DANGER Before you do work on the UPS, read the full installation instructions provided in the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. The full instructions are available for download at www.eaton.com/91psand93ps. Operations inside the UPS must be done by an authorized Eaton Customer Service Engineer or by qualified service personnel authorized by Eaton. There are no userserviceable parts inside the UPS. The UPS operates with mains, battery or bypass power. It contains components that carry high currents and voltage. A properly installed enclosure is earthed and IP20 rated against electrical shock and foreign objects. However, the UPS is a sophisticated power system and only qualified personnel are allowed to install and service it. DANGER This UPS carries lethal voltages. Batteries present a risk of electrical shock or burn from high short circuit current. Obey the precautions. Batteries may contain HIGH VOLTAGES, and CORROSIVE, TOXIC and EXPLOSIVE substances. Because of the battery string the output receptacles may carry high voltage even when the AC supply is not connected to the UPS. Read the shutdown instructions in the User’s and Installation Guide. WARNING The UPS is powered by its own energy source (batteries). The output terminals may be energized even when the UPS is disconnected from an AC source. To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity controlled, indoor environment that is free of conductive contaminants. Do not stack the 91PS/93PS C-model UPS cabinet on top of any other similar cabinet(s). Do not stack anything on the top of the 91PS/93PS UPS cabinet. If the 91PS/93PS Cmodel UPS cabinet is installed on a shelf, use necessary supports to prevent the UPS from tipping or dropping. 2 EN WARNING The ambient temperature must not exceed 40 °C (104 °F). Do not operate the UPS near water or excessive humidity (95% maximum). The system is not intended for outdoor use. Before you start any installation or service work, make sure that all AC and DC power sources are disconnected. Power may come from multiple sources. Also ensure system grounding / PE continuity. In a parallel system, the output terminals may be energized even when the UPS is turned off. Electric energy hazard. To avoid injury, do not attempt to alter any battery wiring or connectors. IMPORTANT: Make sure that you disconnect all battery strings before installation. CAUTION Only qualified service personnel knowledgeable of batteries and the required precautions can do installation or service work on batteries. Installation and service work on batteries is live-line working and requires the use of voltage tools. Keep unauthorized personnel away from the batteries. Before you install or replace batteries, consider all the warnings, cautions, and notes concerning appropriate handling. Do not disconnect the batteries when the UPS is in the Battery mode. Make sure that your replacement batteries are of the same number and type as the battery that was originally installed in the UPS. See more accurate instructions on the UPS. Before you connect or disconnect battery terminals, disconnect the charging source by opening the corresponding battery circuit breaker. Examine if the battery is inadvertently grounded. If it is, remove the source of the ground. Contacting any part of a grounded battery can cause a risk of electric shock. Discard batteries according to your local disposal requirements. Do not discard batteries in a fire. When exposed to flame, batteries may explode. To reduce the risk of a fire, connect only to a circuit that is provided with maximum input circuit breaker current ratings in accordance with the national and local installation rules. To ensure proper cooling airflow and to protect personnel from dangerous voltages inside the unit, keep the UPS door closed and the front panels installed. Do not install or operate the UPS system close to gas or electric heat sources. Keep the operating environment within the parameters stated in this document. Keep the surroundings of the UPS uncluttered, clean, and free from excess moisture. Obey all DANGER, CAUTION, and WARNING notices affixed to the inside and outside of the equipment. 3 EN 2 The Eaton® 91PS/93PS uninterruptible power supply (UPS) is a true online, continuousduty, transformerless, double-conversion, solid-state, single-phase (91PS) or three-phase (93PS) system. It supplies conditioned and uninterruptible AC power to critical load and protects it from power failures. Eaton 91PS/93PS output power ratings are based on 15 kW or 20 kW rated uninterruptible power modules (UPMs). 91PS/93PS is also available as a C-model, which consist of the electrical part of the 91PS/93PS UPS 15/20 kW frame without the battery compartment. Table 1. UPS cabinet ratings Picture (Illustration 1) Number of UPMs Ratings 91PS 15 kW A and B 1 8, 10, 15 kW 91PS 30 kW C 1 or 2 8, 10, 15, 20, 30 kW 93PS 20 kW A and B 1 8, 10, 15 or 20 kW 93PS 40 kW C 1 or 2 8, 10, 15, 20, 30 or 40 kW UPS frame The main parts of the 91PS/93PS UPS 8-40 kW are shown in illustration 2. The main parts are as follows: 1. 2. 3. 4. Control panel Door latch Power module (UPM) Internal battery (not in C-models) 5. 6. 7. 8. Communications area Input switch Battery breaker Maintenance bypass switch (optional) DANGER . This UPS carries lethal voltages. Operations inside the UPS must be done by an authorized Eaton Customer Service Engineer or by qualified service personnel authorized by Eaton. There are no userserviceable parts inside the UPS. For complete safety instructions, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. The UPS must be installed according to the recommendations in the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. Use the following basic sequence of steps to install the UPS: 4 1. 2. 3. 4. 5. 6. Create an installation plan for the UPS system. Prepare your site for the UPS system. Inspect and unpack the UPS cabinet. Unload and install the UPS cabinet and wire the system. Complete the installation checklist. Have authorized service personnel perform the preliminary operational checks and startup. NOTE: Startup and operational checks must be performed by an authorized Eaton Customer Service Engineer or by qualified service personnel authorized by Eaton, or the warranty terms specified in the Warranty become void. Before you install the UPS system, read and understand how these instructions apply to the system that you are going to install. Use the procedures and illustrations provided to create a logical plan for installing the system. For the UPS system to operate at peak efficiency, the installation site must meet the environmental parameters outlined in the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. The installation environment must meet the UPS weight and size requirements provided in Tables 2 and 3. The dimensions of the UPS cabinet are shown in illustration 1. Note that the depth dimension (750 mm) includes cable glands. Table 2. UPS cabinet weights with cardboard packaging C-model 8-20 kW (Illustration 1, picture A) 15/20 kW frame* (Illustration 1, picture B) 30/40 kW frame* (Illustration 1, picture C) Shipping weight 98 kg 293 kg 558 kg Installed weight 86 kg 280 kg 532 kg 310 kg/m2 1107 kg/m2 1478 kg/m2 Floor loading * Maximum internal batteries are included with all models. The UPS cabinets use forced air cooling to regulate internal component temperature. By default, air inlets are in the front of the cabinet and outlets are in the back, see illustration 3. Allow clearance in front of and behind each cabinet for proper air circulation. Make sure that the cooling air that enters the UPS does not exceed +40 °C. For ventilation requirements, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. 5 EN Table 3. UPS cabinet minimum clearances EN 15/20 kW frame (Illustration 1, pictures A and B) 30/40 kW frame (Illustration 1, picture C) From the top of the cabinet 500 mm 500 mm From the front of the cabinet 500 mm 650 mm From the back of the cabinet 150 mm 250 mm From the side of the cabinet 0 mm 0 mm The recommended ambient operating temperature and humidity for the UPS system is shown in illustrations 4.1 and 4.2. An ambient temperature from +20 °C to +25 °C is recommended to achieve a long life of VRLA batteries. Table 4. Minimum recommended multi-core cable and fuse sizes for rectifier and bypass input and UPS output cables (3-phase input, 3-phase output models) 93PS UPS rating (kW) 8 10 15 20 30 40 4*2.5 4*4 4*10 4*10 4*16 4*25 Rectifier fuse [A] 20 20 32 40 63 80 Bypass fuse [A] 20 20 32 40 63 80 PE cable [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Cable [mm2] Maximum conductor cross section 20 kW frame and 20 kW C-model: solid wire 16 mm2, stranded wire with ferrule: 10 mm2 40kW frame: solid wire 70 mm2, stranded wire with ferrule: 50 mm2 Table 5. Minimum recommended multi-core cable and fuse sizes for rectifier and bypass input and UPS output cables (3-phase input, 1-phase output models) 91PS UPS rating (kW) 8 10 15 20 30 Rectifier cable [mm2] 2,5 4 10 10 16 Rectifier fuse [A] 20 20 32 40 63 Bypass, output cable [mm2] 10 16 25 35 70 Bypass fuse [A] 50 63 80 100 160 PE cable [mm2] 10 16 16 16 35 Maximum conductor cross section, 15 kW frame and 15 kW C-model 6 Rectifier: solid wire 16 mm2, stranded wire with ferrule: 10 mm2 Bypass/output: solid wire 70 mm2, stranded wire with ferrule: 50 mm2 91PS UPS rating (kW) Maximum conductor cross section, 30 kW frame 8 10 15 20 30 EN Rectifier: solid wire 70 mm2, stranded wire with ferrule: 50 mm2 Bypass/output: solid wire 95 mm2, stranded wire with ferrule: 95 mm2 CAUTION Make sure that prospective short-circuit current resulting at the UPS input terminals is equal or less than conditional short-circuit current declared on the ratings label of the UPS. Table 6. Minimum recommended cable and fuse sizes for external battery bank UPS rating (kW) 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 Battery fuse [A] 63 63 63 63 160 160 PE cable [mm2] 1*16 1*16 1*16 1*16 1*16 1*16 Pos. & neg. line [mm2] Maximum conductor cross section 15/20 kW frame, C-model and 30/40 kW frame with separate battery: solid wire: 25 mm2, stranded wire with ferrule: 16 mm2 30/40 kW frame with common battery: solid wire: 90 mm2, stranded wire with ferrule: 70 mm2 For information on rated and maximum currents for rated power and voltage, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. For the external separate battery option, there are separate terminals for both battery banks (cabinets), refer to Section 2.3.1. NOTE: External overcurrent protection is not provided by this product, but is required by codes. Refer to Table 4 and 5 for wiring requirements. If a lockable output disconnect is required, it must be supplied by the user. Table 7. UPS power cable terminal torques UPS frame 93PS 20 kW Function Tightening torque Nm X1, X2, X3: L1, L2, L3, N 1.6 X4: battery +/PE (ground) 93PS 40 kW 3 10 Nm for 16-35 mm2 wire 6 Nm for 4-10 mm2 wire 4 Nm for 2.5 mm2 wire X1, X2, X3: L1, L2, L3, N 6 X4: battery +/- 6 PE (ground) 10 Nm for 16-35 mm2 wire 6 Nm for 4-10 mm2 wire 4 Nm for 2.5 mm2 wire 7 UPS frame EN 91PS 15 kW 91PS 30 kW Function Tightening torque Nm X1 1.6 X2, X3 7 X4 3 PE (ground) 10 Nm for 16-35 mm2 wire 6 Nm for 4-10 mm2 wire 4 Nm for 2.5 mm2 wire X1 6 X2, X3 17 X4 6 PE (ground) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Action All packing materials and restraints are removed from each cabinet. Each cabinet in the UPS system is placed in its installed location. A cabinet grounding kit / mounting kit is installed between any cabinets that are bolted together. All conduits and cables are properly routed to the UPS and any ancillary cabinets. All power cables are properly sized and terminated. Neutral conductors are installed and bonded to ground according to the requirements. A ground conductor is properly installed. Battery cables are terminated and connected to battery connectors. Battery Shunt trip and Aux contact signal wiring is connected from the UPS to the battery breaker. LAN drops are installed. All LAN connections are completed. Air conditioning equipment is installed and operating correctly. The area around the installed UPS system is clean and dust-free (it is recommended that the UPS is installed on a level floor suitable for computer or electronic equipment). There is adequate workspace around the UPS and other cabinets. Adequate lighting is provided around all the UPS equipment. A 230 VAC service outlet is located within 7.5 meters of the UPS equipment. The Remote Emergency Power-off (REPO) device is mounted in its installed location and its wiring is terminated inside the UPS cabinet. If EPO is used in the NC configuration, a jumper is installed on the EPO between pins 1 and 2. (OPTIONAL) Alarm relays and signal outputs are wired appropriately. (OPTIONAL) A remote battery disconnect control is mounted in its installed location and its wiring is terminated inside the UPS and battery cabinet. (OPTIONAL) Accessories are mounted in their installed locations and their wiring is terminated inside the UPS cabinet. Start-up and operational checks are performed by an authorized Eaton Customer Service Engineer or by a qualified service engineer authorized by Eaton. 8 Yes/No EN The unpacking and unloading of the UPS is shown in illustrations 9.1 - 9.8. Before you start to unpack and unload the UPS, check the TipNTell and DropNTell indicators on the package surface. If the equipment has been correctly transported in the upright position, the indicators should be intact. If the TipNTell indicator arrow has turned all blue or the arrow head(s) of the DropNTell indicator are black, contact the appropriate parties to report inappropriate transportation. For transportation purposes, the UPS cabinet is bolted onto a wooden pallet. Before you unload the cabinet from the pallet, use a forklift or other material handling equipment to move the cabinet to the installation area. WARNING The UPS cabinet is heavy. If the unpacking instructions are not closely obeyed, the cabinet may tip over and cause serious injury. Do not tilt the UPS cabinet more than 10 degrees from the vertical or the cabinet may tip over. NOTE: After you have removed the shipping brackets, move the unit immediately away from the pallet. After you have removed the shipping brackets and retracted the leveling feet, do not use a forklift to move the unit while it is still on the pallet. Note that the UPS cabinet is heavy and there are casters under the cabinet. If you remove the cabinet from its original installation location and transfer it to a new location on a pallet, lower the leveling feet so that the cabinet is not resting on the casters and attach the shipping brackets to the cabinet and the pallet. The operator has to supply the wiring to connect the UPS to the local power source. The installation of the UPS must be made by a locally qualified electrician. The installation inspection and the initial start-up of the UPS and installing an extra battery cabinet must be carried out by an authorized Eaton Customer Service Engineer or by a qualified service personnel authorized by Eaton. The installation of the UPS is shown in illustrations 10.1-10.5. The UPS power cable terminals are shown in illustrations 6.1 (91PS 15 kW frame), 6.2 (93PS 20 kW frame), 7.1 (91PS 30kW frame with a common battery), 7.2 (91PS 30kW frame with a separate battery option), 8.1 (93PS 40kW frame with a common battery) and 8.2 (93PS 40kW frame with a separate battery option). X1 X2 X3 X4/+ UPM2 Rectifier input Bypass input UPS output External battery + (separate battery) X4/TB20 TB21 PE External battery External battery trip External battery trip Protective earth 9 EN The UPS communication terminals are shown in illustrations 5.1 and 5.2. The terminals are as follows: 1. 2. 3. 4. 5. 6. TB11, not used TB10, not used TB9, not used TB8, external CAN termination TB7, external CAN TB6, pull chain bus 7. 8. 9. 10. USB1, USB host (connection to accessories) USB2, USB device (connection to computer) MiniSlot 1 TB1, signal input 1-5 11. 12. 13. 14. 15. 16. TB2, not used TB3, not used Serial COM port RS-232 MiniSlot 2 TB4, EPO TB5, relay output If installing a customer-supplied battery system, install the battery system according to the battery and battery system manufacturer’s instructions and all the applicable national codes and regulations. For the battery specification, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. The 91PS/93PS 8-40 kW UPS units are always equipped with an internal battery breaker, which affects only the UPS internal batteries (except for the C model, where the internal battery breaker can be used for external batteries). The external battery breaker is a crucial part of the external battery cabinet or rack and must be placed in it. With the external battery breaker, signal cabling is important. Both internal and external battery breakers can be tripped (switched off) by energizing its shunt trip coil. The shunt trip coils of external battery breakers are energized (controlled) through connectors TB20 and TB21 (TB21 available only in the 8-40 kW UPS with separate battery configuration). The default voltage of the shunt trip coil is 24 Vdc. Battery trip wiring is shown in illustration 11. The parts are as follows: A 1 2 External battery breaker Pin 1, shunt trip coil + Pin 2, shunt trip coil - 3 4 Pin 3, AUX contact Pin 4, AUX contact return For instructions on how to install the external battery cabinet and battery power cabling, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide and the instruction manual provided with the external battery cabinet. Earth the external battery cabinet / customer-supplied battery system to the PE terminal 17. EPO is connected to the UPS's top front panel, on connector EPO. The connections of the EPO switch are shown in illustration 12. For information on installing interface connections, refer to the Eaton 91PS/93PS UPS 840 kW User’s and Installation Guide. 10 One general purpose relay contact is provided as a standard feature on the UPS. An alarm contact is also provided. The output relay configurations are shown in illustration 13. You can use a normally-closed or normally-open contact. If the state of the contact changes from the state you specify as normal, a signal is issued. You can connect this contact to equipment at your facility (such as a light or an alarm bell) to let you know when an alarm is active on the UPS. NOTE: Contacts should not be operated in excess of 30 VAC (RMS) and 30 VDC at 5 A maximum. For information on wiring parallel 91PS/93PS UPS systems, refer to the Eaton 91PS/93PS UPS 8-40 kW User’s and Installation Guide. 11 EN 1 GEFAHR DE Wichtige Sicherheitsanweisungen! Bewahren Sie diese Hinweise sicher auf! Dieses Dokument enthält wichtige Sicherheitsanweisungen und eine Kurzanleitung dazu, wie die Lieferung der USV überprüft und installiert wird. Diese Kurzanleitung dient ausschließlich der Verwendung als Installationscheckliste vor Ort. Die Zielgruppe dieses Dokuments sind erfahrene Fachleute, welche die Installation der USV planen und durchführen. GEFAHR Bevor Sie die Arbeiten an der USV aufnehmen, lesen Sie die Installationsanweisungen aus dem Benutzer- und Installationshandbuch der Eaton 91PS/93PS USV 8-40 kW vollständig durch. Die vollständige Anleitung kann unter www.eaton.com/91psand93ps heruntergeladen werden. Arbeiten in der USV müssen von einem autorisierten Eaton-Kundendienstmitarbeiter oder von Kundendienstpersonal ausgeführt werden, das von Eaton qualifiziert wurde. Die USV enthält keine Teile, die vom Benutzer gewartet werden müssen. Die USV arbeitet mit Stromnetz, Batterie oder Bypass. Sie enthält Komponenten, die hohe Ströme und Spannungen führen. Ein ordnungsgemäß installiertes Gehäuse ist geerdet und nach IP20 gegen Stromschlag und Fremdkörper ausgelegt. Die USV ist jedoch ein leistungsstarkes Stromversorgungssystem und sollte nur von qualifiziertem Personal installiert und gewartet werden. GEFAHR Diese USV führt tödliche Spannungen. Batterien stellen eine Gefahr durch Elektroschocks oder Verbrennungen durch Kurzschlussstrom dar. Halten Sie die Sicherheitsvorkehrungen ein. Batterien können HOHE SPANNUNGEN und KORRODIERENDE, GIFTIGE und EXPLOSIVE Substanzen enthalten. Aufgrund der Batteriestränge können die Ausgangsstecker hohe Spannungen aufweisen, auch wenn die AC-Versorgung nicht an der USV angeschlossen ist. Lesen Sie die Abschaltungsanleitungen im Benutzer- und Installationshandbuch. ACHTUNG Die USV wird durch die systemeigene Energiequelle (Batterien) mit Strom versorgt. Die Ausgangsanschlüsse können auch unter Spannung stehen, wenn die USV von der Wechselstromquelle getrennt ist. Um das Risiko eines Brandes oder Stromschlags zu minimieren, installieren Sie diese USV in einem temperatur- und feuchtigkeitsgeregelten Innenraum, der frei von leitenden Verunreinigungen ist. Stapeln Sie den Schrank des USV 91PS/93PS Modells C nicht mit anderen ähnlichen Schränken. Stapel Sie nichts oben auf den 91PS/93PS USV-Schrank. Wenn der Schrank des USV 91PS/93PS Modells C auf einem Regal installiert wird, verwenden Sie die notwendigen Träger, um zu verhindern, dass die USV umkippt oder herunterfällt. 12 ACHTUNG Die Umgebungstemperatur darf 40 °C nicht überschreiten. Betreiben Sie die USV nicht in der Nähe von Wasser oder hoher Feuchtigkeit (maximal 95 %). Das System ist nicht für den Einsatz im Freien geeignet. Bevor Sie mit Installations- oder Wartungsarbeiten beginnen, stellen Sie sicher, dass alle Wechsel- und Gleichstromquellen getrennt wurden. Der Strom kann von verschiedenen Quellen stammen. Achten Sie auch darauf, dass das System geerdet ist / PE-Durchgang hat. In einem Parallelsystem können die Ausgangsanschlüsse auch unter Spannung stehen, wenn die USV abgeschaltet ist. Stromschlaggefahr. Um Verletzungen zu verhindern, führen Sie unter keinen Umständen Änderungen an der Batterieverkabelung oder den Anschlüssen durch. WICHTIG: Vergewissern Sie sich vor der Installation, dass Sie alle Batteriestränge getrennt haben. VORSICHT Nur qualifiziertes Servicepersonal, das Kenntnisse über Batterien und die erforderlichen Sicherheitsvorkehrungen hat, darf Installations- oder Servicearbeiten an Batterien durchführen. Benutzen Sie bei Montage- und Wartungsarbeiten an Batterien geeignetes Werkzeug für Arbeiten an spannungsführenden Teilen. Halten Sie nicht autorisierte Personen von den Batterien fern. Bevor Sie Batterien einbauen oder austauschen, beachten Sie alle Warnungen, Vorsichtsmaßnahmen und Hinweise über eine angemessene Handhabung. Trennen Sie die Batterien nicht, wenn sich die USV im Batteriemodus befindet. Stellen Sie sicher, dass Ihre Austauschbatterien die gleiche Nummer haben und vom gleichen Typ sind, wie die ursprünglich in der USV installierte Batterie. Genauere Anweisungen finden Sie auf der USV. Bevor Sie Batterieanschlüsse verbinden oder trennen, trennen Sie die Ladequelle, indem Sie den entsprechenden Batteriestromkreistrenner öffnen. Prüfen Sie, ob die Batterie versehentlich geerdet wurde. Ist dies der Fall, beseitigen Sie die Erdungsverbindung. Die Berührung von Teilen einer geerdeten Batterie kann zu Stromschlag führen. Entsorgen Sie Batterien gemäß den regionalen Entsorgungsbestimmungen. Werfen Sie die Batterien auf keinen Fall in ein Feuer. Batterien können explodieren, wenn Sie Flammen ausgesetzt werden. Um die Brandgefahr zu verringern, verbinden Sie ausschließlich mit einem Stromkreis, der mit Eingangssicherungen mit den maximalen Nennströmen gemäß den nationalen und lokalen Installationsvorschriften ausgestattet ist. Um einen angemessenen Kühlluftstrom sicherzustellen, um Personen vor gefährlichen Spannungen innerhalb der Einheit zu schützen, halten Sie die USV-Tür geschlossen und die Frontplatten angebracht. Vermeiden Sie die Platzierung bzw. den Betrieb des USV-Systems in der Nähe von Gas oder elektrischen Wärmequellen. Halten Sie die Betriebsumgebung innerhalb der in diesem Dokument angegebenen Parameter. Stellen Sie sicher, dass die Umgebung der USV ordentlich, sauber und frei von übermäßiger Feuchtigkeit ist. Befolgen Sie alle GEFAHR-, VORSICHT- UND ACHTUNG-Hinweise, die innen und außen an der Anlage angebracht sind. 13 DE 2 Die unterbrechungsfreie Stromversorgung (USV) Eaton® 91PS/93PS ist ein echtes Online, Dauerleistungs-, transformatorloses, doppelwandiges, einphasiges (91PS) oder dreiphasiges (93PS) System. Es versorgt kritische Verbraucher mit aufbereitetem und unterbrechungsfreiem Wechselstrom und schützt sie vor Stromausfällen. Die Ausgangsnennleistungen der Eaton 91PS/93PS basieren auf den auf 15 kW oder 20 kW ausgelegten unterbrechungsfreien Leistungsmodulen (UPM). DE 91PS/93PS ist auch als C-Modell erhältlich, welches aus dem elektrischen Teil des 91PS/93PS USV 15/20 kW-Rahmens ohne Batterieabteil besteht. Tabelle 1. USV-Schrankleistungen USV-Rahmen Bild (Abbildung 1) Anzahl der UPM Leistungen 91PS 15 kW A und B 1 8, 10, 15 kW 91PS 30 kW C 1 oder 2 8, 10, 15, 20, 30 kW 93PS 20 kW A und B 1 8, 10, 15 oder 20 kW 93PS 40 kW C 1 oder 2 8, 10, 15, 20, 30 oder 40 kW Die Hauptteile der 91PS/93PS USV 8-40 kW sind in Abbildung 2 dargestellt. Die Hauptteile sind wie folgt: 1. 2. 3. 4. Bedienfeld Türriegel Leistungsmodul (UPM) Interne Batterie (nicht in Modellen C) . 5. 6. 7. 8. Kommunikationsbereich Eingangsschalter Batterietrenner Wartungs-Bypass-Schalter (optional) GEFAHR Diese USV führt tödliche Spannungen. Arbeiten in der USV müssen von einem autorisierten Eaton-Kundendienstmitarbeiter oder von Kundendienstpersonal ausgeführt werden, das von Eaton qualifiziert wurde. Die USV enthält keine Teile, die vom Benutzer gewartet werden müssen. Für die vollständigen Sicherheitsanweisungen, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. Die USV muss gemäß den Empfehlungen des Benutzer- und Installationshandbuchs für die Eaton 91PS/93PS USV 8-40 kW installiert werden. Halten Sie sich zur Installation der USV an die folgende grundsätzliche Reihenfolge der Schritte: 14 1. 2. 3. 4. 5. 6. Erstellen Sie einen Installationsplan für das USV-System. Bereiten Sie Ihren Standort für das USV-System vor. Überprüfen und packen Sie den USV-Schrank aus. Entladen und installieren Sie den USV-Schrank und verkabeln Sie das System. Vervollständigen Sie die Installations-Checkliste. Lassen Sie autorisiertes Servicepersonal die Vorab-Betriebskontrollen durchführen und das System in Betrieb nehmen. HINWEIS: Kontrollen bei der Inbetriebnahme oder während des Betriebs müssen von einem autorisierten Eaton-Kundendienstmitarbeiter oder durch qualifiziertes von Eaton autorisiertes Wartungspersonal durchgeführt werden, andernfalls werden die in der Garantie angegebenen Garantiebedingungen ungültig. Vor der Installation des USV-Systems lesen Sie diese Anweisungen und verstehen Sie, wie sie auf das zu installierende System anzuwenden sind. Verwenden Sie die angegebenen Abläufe und Abbildungen, um einen logischen Plan für die Installation des Systems zu erstellen. Damit das USV-System mit höchster Effizienz läuft, muss der Installationsstandort die Umgebungsparameter erfüllen, die im Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW aufgeführt sind. Die Installationsumgebung muss den Gewichts- und Größenanforderungen der USV laut Tabelle 2 und 3 entsprechen. Die Abmessungen des USV-Schranks sind in Abbildung 1 dargestellt. Beachten Sie, dass die Tiefenabmessungen (750 mm) Kabeleinführungen enthalten. Tabelle 2. Gewichte des USV-Schranks mit Kartonverpackung Modell C 8-20 kW (Abbildung 1, Bild A) 15/20 kW Rahmen* (Abbildung 1, Bild B) 30/40 kW Rahmen* (Abbildung 1, Bild C) Versandgewicht 98 kg 293 kg 558 kg Montagegewicht 86 kg 280 kg 532 kg Bodenbelastung 310 kg/m2 1107 kg/m2 1478 kg/m2 * Maximale Anzahl interner Batterien sind bei allen Modellen enthalten. Die USV-Schränke verwenden Zwangsluftkühlung, um die Innentemperatur der Komponenten zu regulieren. Standardmäßig befinden sich Lufteinlässe in der Vorderseite des Schranks und Auslässe in der Rückseite; siehe Abbildung 3. Lassen Sie für eine ordnungsgemäße Luftzirkulation einen Abstand vor und hinter jedem Schrank. Stellen Sie sicher, dass die Kühlluft, die in die USV einströmt, nicht +40 °C überschreitet. Zu den Kühlungsanforderungen, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. 15 DE Tabelle 3. Mindestabstände für USV-Schränke DE 15/20 kW Rahmen (Abbildung 1, Bilder A und B) 30/40 kW Rahmen (Abbildung 1, Bild C) Von der Oberseite des Schranks 500 mm* 500 mm* Von der Vorderseite des Schranks 500 mm* 650 mm* Von der Rückseite des Schranks 150 mm* 250 mm* 0 mm* 0 mm* Von der Seite des Schranks Die empfohlene Umgebungsbetriebstemperatur und Luftfeuchtigkeit für das USV-System ist in Abbildung 4.1 und 4.2 dargestellt. Eine Umgebungstemperatur von +20 °C bis +25 °C wird empfohlen, um eine lange Lebensdauer der VRLA-Batterien zu erzielen. Tabelle 4. Mindestanforderungen an das Mehrleiterkabel und die Dimensionierung der Sicherungen für den Gleichrichter und den Bypass-Eingang sowie für die USV-Ausgangskabel (Dreiphasen-Eingang, Dreiphasen-Ausgang) 93PS USV-Leistung (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Gleichrichtersicherung [A] 20 20 32 40 63 80 Bypass-Sicherung [A] 20 20 32 40 63 80 PE-Kabel [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] Maximaler Leiterquerschnitt 20 kW Rahmen und 20 kW C-Modell: massiver Draht 16 mm2, Litzendraht mit Pressklemme: 10 mm2 40kW Rahmen: massiver Draht 70 mm 2, Litzendraht mit Pressklemme: 50 mm2 Tabelle 5. Mindestanforderungen an das Mehrleiterkabel und die Dimensionierung der Sicherungen für den Gleichrichter und den Bypass-Eingang sowie für die USV-Ausgangskabel (Dreiphasen-Eingang, Einphasen-Ausgang) 16 91PS USV-Leistung (kW) 8 10 15 20 30 Gleichrichterkabel [mm2] 2,5 4 10 10 16 Gleichrichtersicherung [A] 20 20 32 40 63 Bypass, Ausgangskabel [mm2] 10 16 25 35 70 Bypass-Sicherung [A] 50 63 80 100 160 91PS USV-Leistung (kW) 8 10 15 20 30 PE-Kabel [mm2] 10 16 16 16 35 Maximaler Leiterquerschnitt, 15 kW Rahmen und 15 kW CModell Gleichrichter: massiver Draht 16 mm2, Litzendraht mit Pressklemme: 10 mm2 Bypass/Ausgang: massiver Draht 70 mm 2, Litzendraht mit Pressklemme: 50 mm2 Maximaler Leiterquerschnitt, 30 kW Rahmen Gleichrichter: massiver Draht 70 mm2, Litzendraht mit Pressklemme: 50 mm2 Bypass/Ausgang: massiver Draht 95 mm 2, Litzendraht mit Pressklemme: 95 mm2 DE VORSICHT Stellen Sie sicher, dass der voraussichtliche Kurzschlussstrom, der an den Eingangsanschlüssen der USV auftritt, gleich oder geringer ist als der bedingte Kurzschlussstrom, der auf dem Leistungsschild der USV angegeben ist. Tabelle 6. Empfohlene Mindestkabelstärken und Sicherungsstärken für externe Batteriebank USV-Nennleistung (kW) 8 10 15 20 30 40 Plus- & Minus-Leitung [mm2] 1*16 1*16 1*16 1*16 1*35 1*35 Batteriesicherung [A] 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 PE-Kabel [mm2] Maximaler Leiterquerschnitt 15/20 kW-Rahmen, C-Modell und 30/40 kW-Rahmen mit eigener Batterie: massiver Draht: 25 mm2, Litzendraht mit Pressklemme: 16 mm2 30/40 kW Rahmen mit üblicher Batterie: massiver Draht: 90 mm 2, Litzendraht mit Pressklemme: 70 mm2 Für Informationen zu Nenn- und Maximalströmen, Nennleistung und Spannung, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. Für die Option mit externer separater Batterie sind separate Anschlüsse für beide Batteriebänke (Schaltschränke) vorhanden, siehe Abschnitt 2.3.1. HINWEIS: Externer Überstromschutz wird durch dieses Produkt nicht geboten, ist aber vorschriftsmäßig erforderlich. Anforderungen für die Verkabelung siehe Tabelle 4 und 5. Wenn ein abschließbarer Ausgangstrenner erforderlich ist, muss er vom Benutzer bereitgestellt werden. Tabelle 7. Anzugsmomente der USV-Hauptstromkabelanschlüsse USV-Rahmen 93PS 20 kW Funktion Anzugsmoment Nm X1, X2, X3: L1, L2, L3, N 1.6 X4: Batterie +/- 3 17 USV-Rahmen DE 93PS 40 kW Funktion Anzugsmoment Nm PE (Erde) 10 Nm für 16-35 mm2-Kabel 6 Nm für 4-10 mm2-Kabel 4 Nm für 2,5 mm2-Kabel X1, X2, X3: L1, L2, L3, N 6 X4: Batterie +/- 6 91PS 15 kW 91PS 30 kW PE (Erde) 10 Nm für 16-35 mm2-Kabel 6 Nm für 4-10 mm2-Kabel 4 Nm für 2,5 mm2-Kabel X1 1.6 X2, X3 7 X4 3 PE (Erde) 10 Nm für 16-35 mm2-Kabel 6 Nm für 4-10 mm2-Kabel 4 Nm für 2,5 mm2-Kabel X1 6 X2, X3 17 X4 6 PE (Erde) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Aktion Sämtliche Verpackungsmaterialien und -arretierungen wurden von jedem Schrank entfernt. Jeder Schrank im USV-System ist an seiner vorgesehenen Position platziert. Zwischen Schränken, die miteinander verschraubt werden, ist ein Schrank-Erdungs/Montagesatz installiert. Alle Leitungsrohre und Kabel sind ordnungsgemäß zur USV und allen Hilfsschränken geführt. Alle Stromkabel sind ordnungsgemäß dimensioniert und angeschlossen. Die Neutralleiter sind gemäß den Anforderungen installiert und auf der Erde befestigt. Ein Erdungsleiter ist ordnungsgemäß installiert. Batteriekabel haben Abschlüsse und sind mit Batterieanschlüssen verbunden. Batterie-Arbeitsstromauslöse- und Hilfskontaktsignalverkabelung sind von der USV mit dem Batterietrenner verbunden. LAN-Verbindungspunkte sind installiert. Alle LAN-Verbindungen sind hergestellt. Klimaanlage ist installiert und funktioniert richtig. Der Bereich um das installierte USV-System herum ist sauber und staubfrei (es wird empfohlen, die USV auf einem ebenen Boden zu installieren, der sich für Computer oder elektronische Geräte eignet). Um die USV und die anderen Schränke ist ausreichend Arbeitsplatz vorhanden. Um alle USV-Anlagen ist ausreichend Beleuchtung vorhanden. Eine 230 VAC Servicesteckdose befindet sich innerhalb von 7,5 Metern von der USV- 18 Ja/Nein Aktion Ja/Nein Anlage entfernt. Der Not-Aus-Fernschalter (REPO) ist an seiner vorgesehenen Position montiert und seine Verkabelung innerhalb des USV-Schranks vollständig durchgeführt. Falls der Not-Aus-Schalter in der Öffnerkonfiguration verwendet wird, ist auf dem NotAus-Schalter zwischen den Pins 1 und 2 eine Brücke installiert. (OPTIONAL) Alarmrelais und Signalausgänge sind ordnungsgemäß verkabelt. DE (OPTIONAL) Eine Batterietrenn-Fernsteuerung ist an ihrer Installationsposition montiert und ihre Verkabelung ist innerhalb des USV- und Batterieschranks angeschlossen. (OPTIONAL) Das Zubehör ist in den Installationspositionen montiert und die Verkabelung innerhalb des USV-Schranks durchgeführt. Kontrollen bei der Inbetriebnahme oder während des Betriebs werden von einem autorisierten Eaton-Kundendienstmitarbeiter oder von Kundendienstpersonal ausgeführt, das von Eaton qualifiziert wurde. Das Auspacken und Abladen der USV ist in den Abbildungen 9.1 - 9.8 dargestellt. Bevor Sie beginnen, die USV auszupacken und abzuladen, schauen Sie auf die TipNTell / DropNTell-Anzeige auf der Paketfläche. Falls das Gerät richtig in der aufrechten Position transportiert wurde, müssen die Anzeigen intakt sein. Wenn der TipNTell-Anzeigepfeil ganz blau ist oder die Pfeilspitze(n) der DropNTell-Anzeige schwarz sind, wenden Sie sich an die entsprechenden Personen, um unangemessenen Transport zu melden. Zu Transportzwecken ist der USV-Schrank auf einer Holzpalette festgeschraubt. Bevor Sie den Schrank von der Palette abladen, verwenden Sie einen Gabelstapler oder ein entsprechendes Flurfördermittel, um den Schrank zum Installationsort zu bewegen. ACHTUNG Der USV-Schrank ist schwer. Wenn die Auspackanweisungen nicht genau beachtet werden, kann der Schrank kippen und ernsthafte Verletzungen verursachen. Kippen Sie den USV-Schrank um nicht mehr als 10° aus der Vertikalen, ansonsten kann der Schrank umkippen. HINWEIS: Nachdem Sie die Transportstützen entfernt haben, bewegen Sie die Einheit sofort von der Palette herunter. Nachdem Sie die Transportstützen entfernt und die Nivellierfüße hineingedreht haben, verwenden Sie keinen Gabelstapler, um die Einheit zu bewegen, während sie sich noch auf der Palette befindet. Beachten Sie, dass der USV-Schrank schwer ist und unter dem Schrank über Rollen verfügt. Wenn der Schrank von seiner ursprünglichen Installationsposition entfernt und auf einer Palette zu einem neuen Standort gebracht wird, müssen die Nivellierfüße abgesenkt werden, sodass Schrank nicht mehr auf den Rollen ruht, und die Versandklammern müssen am Schrank und der Palette angebracht werden. 19 Der Betreiber muss die Verkabelung bereitstellen, mit der die USV an die lokale Stromquelle angeschlossen wird. Die Installation der USV muss von einem ausgebildeten Elektroinstallateur durchgeführt werden. Die Überprüfung der Installation und der erste Startvorgang der USV sowie das Installieren eines zusätzlichen Batterieschranks dürfen nur von einem autorisierten Eaton-Kundendienstmitarbeiter oder Kundendienstpersonal ausgeführt werden, das von Eaton qualifiziert wurde. DE Die Installation der USV ist in den Abbildungen 10.1-10.5 dargestellt. Die USV-Stromkabelklemmen sind in den Abbildungen 6.1 (Rahmen 91PS 15 kW), 6.2 (Rahmen 93PS 20 kW), 7.1 (Rahmen 91PS 30 kW mit gemeinsamer Batterie), 7.2 (Rahmen 91PS 30 kW mit separater Batterieoption), 8.1 (Rahmen 93PS 40 kW mit gemeinsamer Batterie) und 8.2 (Rahmen 93PS 40 kW mit separater Batterieoption) dargestellt. X1 X2 X3 X4/+ UPM2 Gleichrichtereingang Bypass-Eingang USV-Ausgang Externe Batterie + (separate Batterie) X4/TB20 TB21 PE Externe Batterie Externe Batterieauslösung Externe Batterieauslösung Schutzleiter Die USV-Kommunikationsanschlüsse sind in Abbildungen 5.1 und 5.2 dargestellt. Die Anschlüsse sind wie folgt: 1. 2. 3. 4. 5. 6. TB11, nicht verwendet TB10, nicht verwendet TB9, nicht verwendet TB8, externe CANTerminierung TB7, externer CAN TB6, Pull Chain-Bus 7. USB1, USB Host (Verbindung zu Zubehörgeräten) 8. USB2, USB-Gerät (Verbindung zum Computer) 9. MiniSlot 1 10. TB1, Signaleingang 1-5 11. TB2, nicht verwendet 12. TB3, nicht verwendet 13. Serieller COM-Port RS232 14. MiniSlot 2 15. TB4, Not-Aus-Schalter 16. TB5, Relais-Ausgang Falls Sie ein Kundeneigenes Batteriesystem installieren, gehen Sie bei der Installation nach den Anweisungen und anwendbaren Richtlinien und Vorschriften des Herstellers der Batterie und des Batteriesystems vor. Für die Batterievorgaben, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. Die 91PS/93PS 8-40 kW USV-Einheiten sind immer mit einem internen Batterieunterbrecher ausgestattet, welcher sich nur auf die internen Batterien der USV auswirkt (außer beim Modell C, wo der interne Batterieunterbrecher für externe Batterien verwendet werden kann). Der externe Batterietrenner ist ein äußerst wichtiges Teil des externen Batterieschranks oder Racks und muss sich unbedingt darin befinden. Beim externen Batterietrenner ist die Signalverkabelung wichtig. Sowohl interner als auch externer Batterietrenner können ausgelöst (abgeschaltet) werden, indem deren Arbeitsstrom-Auslösespule angesteuert wird. Die ArbeitsstromAuslösespulen der externen Batterietrenner werden über die Stecker TB20 und TB21 angesteuert (TB21 steht nur bei der 8-40 kW USV mit separater Batteriekonfiguration zur Verfügung). Die voreingestellte Spannung der Arbeitsstrom-Auslösespule beträgt 24 Vdc. 20 Die Batterieauslöseverkabelung wird in Abbildung 11 dargestellt. Die Teile sind wie folgt: A 1 2 Externer Batterietrenner Pin 1, ArbeitsstromAuslösespule + Pin 2, ArbeitsstromAuslösespule - 3 4 Pin 3, Hilfskontakt Pin 4, Hilfskontakt-Rückfluss DE Anweisungen zur Installation des externen Batterieschranks und zur Verkabelung der Batterie sind dem Benutzer- und Installationshandbuch für die Eaton 91PS/93PS 8-40 kW und dem Anleitungshandbuch des externen Batterieschranks zu entnehmen. Erden Sie den externen Batterieschrank / das vom Kunden bereitgestellte Batteriesystem mit dem PE-Anschluss 17. Der Not-Aus-Schalter wird an der oberen Frontplatte der USV, am Not-Aus-SchalterVerbinder, angeschlossen. Die Anschlüsse des Not-Aus-Schalters sind in Abbildung 12 dargestellt. Für Informationen zur Installation der Schnittstellenverbindungen, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. Ein Universal-Relaiskontakt wird als Standardfunktion der USV geliefert. Ein Alarmkontakt steht ebenfalls zur Verfügung. Die Ausgaberelaiskonfigurationen sind in Abbildung 13 dargestellt. Sie können einen Öffner- oder Schließerkontakt verwenden. Wenn der Status von dem als normal angegebenen Status abweicht, ertönt ein Signal. Sie können diesen Kontakt mit der Anlage in Ihrer Einrichtung (wie z. B. einem Licht oder einer Alarmglocke) verbinden, damit Sie wissen, wann ein Alarm in der USV aktiv ist. HINWEIS: Kontakte sollten nicht bei mehr als 30 VAC (RMS) und 30 VDC bei maximal 5 A betrieben werden. Für Informationen zur Verkabelung paralleler 91PS/93PS-USV-Systeme, siehe das Benutzer- und Installationshandbuch für die Eaton 91PS/93PS USV 8-40 kW. 21 1 DANGER Instructions importantes pour la sécurité ! Conservez ces instructions ! Ce document fournit des instructions importantes relatives à la sécurité et des instructions succinctes pour le contrôle de la livraison et le mode d'installation de l'UPS. Ce guide rapide est uniquement destiné à servir de liste de contrôle de l'installation sur site. FR Ce document est destiné à un public de professionnels expérimentés qui planifient et exécutent l'installation de l'UPS. DANGER Avant de travailler sur l'UPS, lisez l'intégralité des instructions d'installation fournies dans le Guide d'utilisation et d'installation des UPS Eaton 91PS/93PS 8-40 kW. Les instructions complètes sont disponibles en téléchargement sur www.eaton.com/91psand93ps. Les opérations à l'intérieur de l'UPS doivent être réalisées par un ingénieur agréé du service client d'Eaton ou par le personnel d'entretien qualifié agréé par Eaton. Aucune partie de l'UPS ne peut être entretenue par l'utilisateur. L'UPS fonctionne à l'aide d'une alimentation secteur, par batteries ou de dérivation. Il contient des composants qui véhiculent des courants et tensions élevés. Pour être correctement installé, son châssis doit être mis à la masse et protégé conformément à la norme IP20 contre les chocs électriques et la pénétration de corps étrangers. Toutefois, l'UPS est un système d'alimentation sophistiqué qui ne peut être installé et entretenu que par du personnel qualifié. DANGER Cet UPS renferme des tensions mortelles. Les batteries présentent un risque de choc électrique ou de brûlure dû à un courant de court-circuit élevé. Respectez les précautions. Les batteries peuvent contenir des TENSIONS ÉLEVÉES, ainsi que des substances CORROSIVES, TOXIQUES et EXPLOSIVES. Les batteries étant en chaîne, les prises de sortie peuvent présenter une tension élevée même si l'alimentation CA n'est pas connectée à l'UPS. Lisez les instructions d'arrêt du Guide d'utilisation et d'installation. AVERTISSEMENT L'UPS est alimenté par sa propre source d'énergie (batteries). Les bornes de sortie peuvent être actives, même si l'UPS est déconnecté d'une source d'alimentation CA. Pour réduire le risque d'incendie ou de choc électrique, installez cet UPS dans un environnement intérieur où la température et l'humidité sont contrôlées et exempt de contaminants conducteurs. N'empilez pas l'armoire d'UPS 91PS/93PS modèle C sur d'autres armoires similaires. N'empilez rien au sommet de l'armoire d'UPS 91PS/93PS. Si l'armoire d'UPS 91PS/93PS modèle C est installée sur une étagère, utilisez les supports nécessaires pour éviter que l'UPS ne bascule ou ne chute. 22 AVERTISSEMENT La température ambiante ne doit pas dépasser 40 °C. N'utilisez pas l'UPS à proximité d'eau ou dans une humidité excessive (95 % maximum). Le système n'est pas prévu pour un usage en extérieur. Avant tout travail d'installation ou d'entretien, assurez-vous que toutes les sources d'alimentation CA et CC sont déconnectées. L'alimentation peut provenir de plusieurs sources. Assurez-vous aussi de la mise à la terre et de la continuité PE du système. Dans un système parallèle, les bornes de sortie peuvent être sous tension même si l'UPS est arrêté. Risque électrique. Pour éviter les blessures, ne tentez pas de modifier un quelconque câblage ou connecteur des batteries. IMPORTANT : Assurez-vous de déconnecter tous les chaînes de batteries avant l'installation. ATTENTION Seul un personnel d'entretien qualifié, familier des batteries et des précautions requises, est autorisé à assurer les travaux d'installation ou d'entretien sur les batteries. Les travaux d'installation et d'entretien sur les batteries s'effectuent sous tension et nécessitent l'usage d'outils de tension. Maintenez le personnel dépourvu d'autorisation à distance des batteries. Avant d'installer ou de remplacer des batteries, tenez compte de tous les avertissements, précautions et notes concernant la manutention correcte. Ne déconnectez pas les batteries si l'UPS est en mode batterie. Assurez-vous de remplacer les batteries par un nombre et un type de batteries respectant l'installation d'origine dans l'UPS. L'UPS fournit des instructions plus précises. Avant de connecter ou déconnecter les bornes de batterie, déconnectez la source de chargement en ouvrant le disjoncteur de batterie correspondant. Vérifiez que la batterie n'est pas reliée à la terre par inadvertance. Si c'est le cas, supprimez cette mise à la terre. Tout contact avec un élément d'une batterie mise à la terre risque de provoquer un choc électrique. Mettez les batteries au rebut selon vos impératifs de mise au rebut locaux. Ne jetez pas les batteries dans un feu. Exposées à des flammes, les batteries peuvent exploser. Afin de réduire le risque d'incendie, connectez uniquement à un circuit respectant les valeurs nominales maximales pour le courant d'entrée du disjoncteur, conformément aux règles d'installation nationales et locales. Afin d'assurer un flux d'air de refroidissement approprié et de protéger le personnel des tensions dangereuses dans l'unité, maintenez la porte de l'UPS fermée et les panneaux avant en place. N'installez ou n'utilisez pas le système UPS à proximité de sources de chaleur électrique ou à gaz. Maintenez l'environnement de fonctionnement dans les paramètres mentionnés dans ce document. Maintenez les alentours de l'UPS dégagés, propres et exempts d'humidité excessive. Observez toutes les notifications DANGER, ATTENTION et AVERTISSEMENT apposées à l'intérieur et à l'extérieur de l'équipement. 23 FR 2 Les systèmes d'alimentation sans interruptions (UPS) Eaton® 91PS/93PS 8-10 kW sont de véritables systèmes en ligne, à fonctionnement continu, sans transformateur, doubleconversion, à semi-conducteurs, monophasés (91PS) ou triphasés (93PS). Ils fournissent une alimentation CA conditionnée et sans coupure vers la charge critique pour la protéger contre les coupures d'électricité. Les valeurs nominales de puissance de sortie de l'Eaton 91PS/93PS sont basées sur des modules d'alimentation sans coupure (UPM) avec une valeur nominale de 15 ou 20 kW. FR Le modèle 91PS/93PS est aussi disponible dans sa version C qui comprend la partie électrique du châssis de l'UPS 91PS/93PS 15/20 kW mais sans le compartiment de batteries. Tableau 1. Valeurs nominales de l'armoire de l'UPS Châssis d'UPS Image (Illustration 1) Nombre d'UPM Valeurs nominales 91PS 15 kW A et B 1 8, 10 ou 15 kW 91PS 30 kW C 1 ou 2 8, 10, 15, 20 ou 30 kW 93PS 20 kW A et B 1 8, 10, 15 ou 20 kW 93PS 40 kW C 1 ou 2 8, 10, 15, 20, 30 ou 40 kW Les pièces principales de l'UPS 91PS/93PS 8-40 kW sont indiquées dans l'illustration 2. Les pièces principales sont les suivantes : 1. 2. 3. 4. . Panneau de commande Verrou de porte Module d'alimentation (UPM) Batterie interne (sauf modèles C) 5. 6. 7. 8. Zone de communications Commutateur d'entrée Disjoncteur de batterie Commutateur de dérivation de maintenance (en option) DANGER Cet UPS renferme des tensions mortelles. Les opérations à l'intérieur de l'UPS doivent être réalisées par un ingénieur agréé du service client d'Eaton ou par le personnel d'entretien qualifié agréé par Eaton. Aucune partie de l'UPS ne peut être entretenue par l'utilisateur. Pour des instructions complètes relatives à la sécurité, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. L'UPS doit être installé selon les recommandations du Guide d'utilisation et d'installation de l'UPSD Eaton 91PS/93PS 8-40 kW. Procédez comme suit et dans l'ordre pour installer l'UPS : 24 1. 2. 3. 4. 5. 6. Créez un plan d'installation pour le système UPS. Préparez le site pour le système UPS. Inspectez et déballez l'armoire de l'UPS. Déchargez et installez l'armoire de l'UPS, puis câblez le système. Remplissez la liste de contrôle de l'installation. Organisez la venue d'un personnel qualifié pour la mise en service et la vérification du bon fonctionnement. NOTE : La mise en service et la vérification du bon fonctionnement devront être exécutées par un ingénieur du service clientèle d'Eaton ou par le personnel d'entretien qualifié agréé par Eaton ; autrement, les conditions générales de la garantie énoncées dans la Garantie sont annulées. Avant d'installer le système UPS, il est indispensable de lire et de comprendre comment ce manuel s'applique au système à installer. Utilisez les procédures et illustrations fournies pour créer un plan logique d'installation du système. Afin que le système UPS puisse fonctionner avec une efficience optimale, le site d'installation doit être conforme aux conditions environnementales exposées dans le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. Le cadre d'installation doit être conforme aux exigences de poids et d'encombrement de l'UPS énoncées aux Tableaux 2 et 3. Les dimensions de l'armoire d'UPS sont indiquées dans l'illustration 1. Notez que la dimension de profondeur (750 mm) inclut les presse-étoupe. Tableau 2. Poids des armoires UPS avec emballage carton Modèle C 8-20 kW (Illustration 1, image A) Châssis 15/20 kW* (Illustration 1, image B) Châssis 30/40 kW* (Illustration 1, image C) Poids pour l'expédition 98 kg 293 kg 558 kg Poids installé 86 kg 280 kg 532 kg Charge au sol 310 kg/m2 1107 kg/m2 1478 kg/m2 * Des batteries internes maximum sont incluses avec tous les modèles. Les armoires UPS utilisent un apport d'air froid pulsé pour réguler la température des composants internes. Par défaut, les entrées d'air sont situées à l'avant de l'armoire et les sorties sont situées à l'arrière - voir illustration 3. Prévoyez un dégagement suffisant devant et derrière chaque armoire pour une circulation d'air correcte. La température de l'air froid qui pénètre dans l'UPS ne doit pas dépasser +40 °C Pour les besoins de ventilation, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. 25 FR Tableau 3. Dégagements minimum autour de l'armoire de l'UPS FR Châssis 15/20 kW (Illustration 1, images A et B) Châssis 30/40 kW (Illustration 1, image C) Depuis le haut de l'armoire 500 mm 500 mm Depuis l'avant de l'armoire 500 mm 650 mm Depuis l'arrière de l'armoire 150 mm 250 mm Depuis le côté de l'armoire 0 mm 0 mm Les température et humidité ambiantes de service recommandées pour le système UPS sont indiquées dans les illustrations 4.1 et 4.2. Une température ambiante entre +20 °C et +25 °C est recommandée pour assurer un cycle de vie prolongé des batteries VRLA. Tableau 4. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour les câbles d'entrée de redresseur et dérivation et de sortie d'UPS (entrée triphasée - sortie triphasée) Nominal d'UPS 93PS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Fusible de redresseur [A] 20 20 32 40 63 80 Fusible de dérivation [A] 20 20 32 40 63 80 Câble PE [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Câble [mm2] Section maximum de conducteur Châssis 20 kW et modèle C 20 kW : fil plein de 16 mm2, fil torsadé avec férule : 10 mm2 Châssis 40kW : fil plein de 70 mm2, fil torsadé avec férule : 50 mm2 Tableau 5. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour les câbles d'entrée de redresseur et dérivation et de sortie d'UPS (entrée triphasée - sortie monophasée) Nominal d'UPS 91PS (kW) 8 10 15 20 30 Câble de redresseur [mm2] 2,5 4 10 10 16 Fusible de redresseur [A] 20 20 32 40 63 Dérivation, câble de sortie [mm2] 10 16 25 35 70 Fusible de dérivation [A] 50 63 80 100 160 Câble PE [mm2] 10 16 16 16 35 Section maximum de conducteur, châssis 15 kW et modèle C 15 kW 26 Redresseur : fil plein de 16 mm2, fil torsadé avec férule : 10 mm2 Dérivation /sortie : fil plein de 70 mm 2, fil torsadé avec férule : 50 mm2 Nominal d'UPS 91PS (kW) Section maximum de conducteur, châssis 30 kW 8 10 15 20 30 Redresseur : fil plein de 70 mm2, fil torsadé avec férule : 50 mm2 Dérivation /sortie : fil plein de 95 mm 2, fil torsadé avec férule : 95 mm2 ATTENTION Assurez-vous que le courant de court-circuit prévu résultant sur les bornes d'entrée de l'UPS est égal ou inférieur à celui du courant de court-circuit conditionnel de la plaque de type de l'UPS. Tableau 6. Tailles minimales recommandées des câbles multiconducteurs et fusibles pour le banc de batteries externe Nominal d'UPS (kW) Ligne pos. & nég. [mm2] Fusible de batterie [A] Câble PE [mm2] Section maximum de conducteur 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Châssis 15/20 kW, modèle C et châssis 30/40 kW avec batterie séparée : fil plein : 25 mm2, fil torsadé avec férule : 16 mm2 Châssis 30/40 kW avec batterie standard : fil plein : 90 mm2, fil torsadé avec férule : 70 mm2 Pour en savoir plus sur les courants nominaux et maximum pour les puissances et tension nominales, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. Pour l'option batterie séparée externe, des terminaux distincts sont prévus pour les deux bancs de batteries (armoires) - voir la section 2.3.1. NOTE : La protection externe contre les surintensités n'est pas fournie par ce produit mais elle est exigée par la réglementation. Pour les exigences de câblage, se reporter à tableaux 4 et 5. Si un dispositif de déconnexion verrouillable de sortie est requis, il doit être fourni par l'utilisateur. Tableau 7. Couples de bornes de câble d'alimentation d'UPS Châssis d'UPS 93PS 20 kW Fonction Couple de serrage (Nm) X1, X2, X3 : L1, L2, L3, N 1.6 X4 : batterie +/PE (terre) 93PS 40 kW 3 10 Nm pour fil de 16-35 mm2 6 Nm pour fil de 4-10 mm2 4 Nm pour fil de 2,5 mm2 X1, X2, X3 : L1, L2, L3, N 6 X4 : batterie +/- 6 27 FR Châssis d'UPS Fonction Couple de serrage (Nm) PE (terre) 10 Nm pour fil de 16-35 mm2 6 Nm pour fil de 4-10 mm2 4 Nm pour fil de 2,5 mm2 X1 1.6 X2, X3 7 X4 3 PE (terre) 10 Nm pour fil de 16-35 mm2 6 Nm pour fil de 4-10 mm2 4 Nm pour fil de 2,5 mm2 X1 6 X2, X3 17 X4 6 PE (terre) 7 Nm (X1, X2, X3) 3.5 Nm (X4) 91PS 15 kW FR 91PS 30 kW Action Tous les matériaux d'emballage et accessoires de fixation sont retirés de chaque armoire. Chaque armoire du système UPS est placée sur son site d'installation. Un kit de mise à la terre/montage de l'armoire est installé entre les armoires boulonnées ensemble. Tous les câbles et gaines sont correctement acheminés vers l'UPS et les armoires auxiliaires. Tous les câbles d'alimentation sont aux bonnes dimensions et raccordés correctement. Les conducteurs neutres sont raccordés ou liés à la masse conformément aux exigences. Un conducteur de terre est correctement installé. Les câbles de batterie sont raccordés aux connecteurs de batterie. Un shunt de dérivation et un câblage de signal de contact auxiliaire sont connectés de l'UPS vers le disjoncteur de batterie. Des branchements LAN sont installés. Toutes les connexions LAN sont exécutées. La climatisation est installée et fonctionne correctement. La zone autour du système UPS installé est propre et dépoussiérée (Il est recommandé d'installer le système UPS sur un sol adapté à l'équipement informatique ou électronique). Un dégagement adéquat est prévu autour de l'UPS et des autres armoires. Un éclairage correct est prévu autour de tout l'équipement de l'UPS. Il existe une prise de courant de service de 230 V CA à 7,5 mètres au plus du site d'installation de l'UPS. Le dispositif d'arrêt d'urgence à distance (REPO) est correctement installé et son câblage est raccordé à l'intérieur de l'armoire de l'UPS. Si l'EPO est utilisé dans la configuration NF, un cavalier est installé sur l'EPO entre les broches 1 et 2. 28 Oui/Non Action Oui/Non (OPTION) Les relais d'alarme et sorties de signal sont correctement câblés. (OPTION) Une commande de déconnexion de batterie à distance est montée sur son site d'installation et son câblage est raccordé à l'intérieur de l'armoire de l'UPS et à l'armoire de la batterie. (OPTION) Les accessoires sont montés sur leur site d'installation et leurs câblages sont raccordés à l'intérieur de l'armoire de l'UPS. La mise en service et la vérification du bon fonctionnement sont réalisées par un ingénieur agréé du service client d'Eaton ou par l'ingénieur d'entretien qualifié agréé par Eaton. FR Le déballage et le déchargement de l'UPS sont indiqués dans les illustrations 9.1 - 9.8. Avant de commencer à déballer et décharger l'UPS, vérifiez l'indicateur TipNTell / DropNTell sur la surface de l'emballage. Si l'équipement a été correctement transporté en position verticale, les indicateurs devraient être intacts. Si la flèche de l'indicateur TipNTell est devenue toute bleue ou si la ou les flèches de l'indicateur DropNTell sont noires, contactez les parties concernées pour déclarer un transport incorrect. Pour son transport, l'armoire de l'UPS est boulonnée sur la palette en bois. Avant de la décharger de la palette, utilisez un chariot élévateur ou tout autre équipement de manutention pour déplacer l'armoire vers le site d'installation. AVERTISSEMENT L'armoire de l'UPS est lourde. Si les instructions de déballage ne sont pas suivies à la lettre, l'armoire risque de basculer et de provoquer des blessures graves. N'inclinez pas l'armoire de l'UPS à un angle supérieur à 10 degrés depuis la verticale : elle pourrait basculer. NOTE : Une fois les supports d'expédition retirés, écartez immédiatement l'unité de la palette. Une fois les supports d'expédition retirés et les pieds de réglage rentrés, n'utilisez pas de chariot élévateur pour déplacer l'unité tant qu'elle se trouve sur la palette. Notez que l'armoire de l'UPS est lourde et que des roulettes sont situées dessous. Si l'armoire est déplacée de son emplacement d'installation d'origine vers un nouvel emplacement sur une palette, les pieds de réglage doivent être abaissés jusqu'à ce que l'armoire ne repose plus sur les roulettes et les supports d'expédition doivent être fixés sur l'armoire et la palette. L'opérateur doit fournir le câblage pour la connexion de l'UPS à la source d'alimentation locale. L'installation de l'UPS doit être confiée à un électricien local qualifié. L'inspection de l'installation et la mise en service initiale de l'UPS ainsi que l'installation d'une armoire de batteries supplémentaire doivent être effectuées par un ingénieur agréé du service client d'Eaton ou par un personnel d'entretien qualifié agréé par Eaton. 29 L'installation de l'UPS est indiquée dans les illustrations 10.1-10.5. Les bornes de câble d'alimentation de l'UPS sont illustrées en 6.1 (91PS châssis 15 kW), 6.2 (93PS châssis 20 kW), 7.1 (91PS châssis 30kW avec batterie commune), 7.2 (91PS châssis 30kW avec option de batterie séparée), 8.1 (93PS châssis 40kW avec batterie commune) et 8.2 (93PS châssis 40kW avec option de batterie séparée). X1 X2 X3 X4/+ UPM2 FR Entrée de redresseur Entrée de dérivation Sortie de l'UPS Batterie externe + (batterie séparée) X4/TB20 TB21 PE Batterie externe Excitation de batterie externe Excitation de batterie externe Terre de protection Les bornes de communication de l'UPS sont illustrées en 5.1 et 5.2. Les bornes sont les suivantes : 1. 2. 3. 4. 5. 6. TB11, sans usage TB10, sans usage TB9, sans usage TB8, raccordement CAN externe TB7, CAN externe TB6, bus de chaînage 2.3.2 7. USB1, hôte USB (connexion aux accessoires) 8. USB2, dispositif USB (connexion à l'ordinateur) 9. Mini-Slot 1 10. TB1, entrée de signal 1-5 11. 12. 13. 14. 15. 16. TB2, sans usage TB3, sans usage Port COM série RS-232 Mini-Slot 2 TB4, EPO TB5, sortie de relais Installation du système de batteries S'il s'agit de l'installation d'un système de batteries fourni par le client, installez le système de batterie conformément aux instructions du fabricant de batterie et du système de batteries et conformément à tous les codes et réglementations nationaux applicables. Pour les spécifications de batterie, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. Les unités UPS 91PS/93PS 8-40 kW sont toujours équipées d'un disjoncteur de batteries internes qui affecte uniquement les batteries internes de l'UPS (sauf pour le modèle C dont le disjoncteur de batteries internes peut servir pour les batteries externes). Le disjoncteur des batteries externes est un élément crucial de l'armoire ou de la baie de batteries externes et doit y être placé. Le câblage de signalisation est important avec le disjoncteur de batterie externe. Les disjoncteurs de batteries externes et internes peuvent être déclenchés (mis hors tension) tous deux en mettant sous tension leur bobine d'excitation de shunt. Les bobines d'excitation de shunt des disjoncteurs de batteries externes sont excitées (commandées) via les connecteurs TB20 et TB21 (TB21 uniquement disponible pour UPS 8-40 kW avec configuration de batterie séparée). La tension par défaut de la bobine d'excitation de shunt est de 24 V CC. Le câblage de la chaîne de batteries est indiqué en illustration 11. Les pièces sont les suivantes : A 1 2 30 Disjoncteur de batteries externes Broche 1, bobine d'excitation de shunt + Broche 2, bobine d'excitation de shunt - 3 4 Broche 3, contact AUX Broche 4, retour de contact AUX Pour les instructions d'installation de l'armoire de batteries externes et le câblage d'alimentation de batterie, consultez le Guide d'utilisation et d'installation des UPS Eaton 91PS/93PS 8-40 kW et le manuel d'instructions accompagnant l'armoire de batteries externes. Mettez à la terre l'armoire de batteries externes /système de batteries fourni par le client à la borne PE 17 illustrée. L'EPO doit être raccordé au connecteur d'EPO du panneau avant supérieur de l'UPS. Les connexions du commutateur EPO sont indiquées dans l'illustration 12. Pour en savoir plus sur l'installation des connexions d'interface, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. Un contact de relais à usage général est installé comme fonctionnalité standard sur l'UPS. Un contact d'alarme est également fourni. Les configurations de relais de sortie sont indiquées en illustration 13. Utiliser un contact normalement fermé ou normalement ouvert. Si l'état du contact change par rapport à l'état spécifié comme normal, un signal est émis. Ce contact peut être connecté à l'équipement du bâtiment (par exemple, un éclairage ou une sonnette d'alarme) afin d'avertir quand une alarme est active sur l'UPS. NOTE : Les contacts ne doivent pas fonctionner au-delà de 30 V CA (RMS) et 30 V CC, à un maximum de 5 A. Pour en savoir plus sur le câblage en parallèle des systèmes d'UPS 91PS/93PS, consultez le Guide d'utilisation et d'installation de l'UPS Eaton 91PS/93PS 8-40 kW. 31 FR 1 VAARA Tärkeitä turvallisuusohjeita! Pidä nämä ohjeet tallessa! Tässä asiakirjassa on tärkeitä turvallisuusohjeita ja lyhyet ohjeet UPS:n toimituksen tarkistuksesta ja UPS:n asennuksesta. Tämä pikaopas on tarkoitettu käytettäväksi vain asennuksen tarkistuslistana asennuspaikalla. Tämä asiakirja on tarkoitettu UPS:n asennuksen suunnitteleville ja suorittaville kokeneille ammattilaisille. FI VAARA Ennen töiden aloittamista UPS:llä lue täydelliset asennusohjeet, jotka on annettu Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaassa. Täydet ohjeet ovat ladattavissa osoitteesta: www.eaton.com/91psand93ps. Työt UPS:n sisäpuolella saa suorittaa vain valtuutettu Eatonin asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltohenkilöstö. UPS:n sisällä ei ole käyttäjän huollettavissa olevia osia. UPS toimii verkkovirran, akkuvirran tai ohitustehon varassa. Se sisältää komponentteja, joissa kulkee suuria virtoja ja korkea jännite. Oikein asennettu kotelo on maadoitettu, ja sillä on IP20-suojausluokitus sähköiskuja ja vierasesineitä vastaan. UPS on kuitenkin kehittynyt virransyöttöjärjestelmä, ja vain pätevä henkilöstö saa tehdä asennus- ja huoltotöitä UPS:lle. VAARA UPS:ssä on hengenvaarallisia jännitteitä. Akut voivat muodostaa suuren oikosulkuvirran vuoksi sähköiskun tai palovammojen riskin. Noudata varotoimia. Akut saattavat sisältää KORKEITA JÄNNITTEITÄ sekä SYÖVYTTÄVIÄ, MYRKYLLISIÄ ja PALAVIA aineita. Akkusarjasta johtuen lähtöliittimissä saattaa olla korkea jännite, vaikka vaihtovirtalähdettä ei ole liitetty UPS:ään. Lue sammutusohjeet käyttö- ja asennusoppaasta. VAROITUS UPS saa virtaa omista energianlähteistään (akustot). Lähtöliittimet saattavat olla jännitteisiä silloinkin, kun UPS on kytketty irti vaihtovirtalähteestä. Tulipalo- tai sähköiskuriskin vähentämiseksi tämä UPS on asennettava sisätilaan, paikkaan, jossa lämpötilaa ja kosteutta valvotaan ja jossa ei ole sähköä johtavia epäpuhtauksia. Älä pinoa UPS 91PS/93PS C -mallin kaappia muiden vastaavien kaappien päälle. Älä pinoa mitään 91PS/93PS UPS -kaapin päälle. Jos UPS 91/93PS C -mallin kaappi asennetaan hyllylle, käytä tarpeellisia tukia estämään UPS:n kaatuminen tai putoaminen. 32 VAROITUS Ympäristön lämpötila ei saa ylittää arvoa 40 °C. Älä käytä UPS-laitetta veden läheisyydessä tai hyvin kosteassa ympäristössä (enintään 95 %). Järjestelmää ei ole tarkoitettu ulkokäyttöön. Varmista ennen asennus- tai huoltotyön aloittamista, että kaikki vaihto- ja tasasähkölähteet on irrotettu. Virtaa voi tulla useista lähteistä. Varmista myös järjestelmän maadoitus / PE-eheys. Rinnakkaisjärjestelmässä lähtöliittimet saattavat olla jännitteisiä silloinkin, kun UPS on sammutettu. Sähkövaara. Estä loukkaantuminen. Älä yritä vaihtaa akkujen kytkentöjä tai liittimiä. TÄRKEÄÄ: Varmista ennen asennusta, että irrotat kaikki akkusarjat. FI HUOMAUTUS Akkujen asennus- ja huoltotöitä saa suorittaa vain akut ja vaadittavat varotoimet tunteva pätevä huoltohenkilöstö. Akkujen asennus ja huolto on jännitetyö ja edellyttää jännitetyökalujen käyttöä. Älä päästä valtuuttamatonta henkilöstöä käsittelemään akkuja. Harkitse ennen akkujen asennusta tai vaihtoa kaikkia akkujen asianmukaiseen käsittelyyn liittyviä varoituksia, huomautuksia ja ilmoituksia. Älä kytke akkuja irti silloin, kun UPS toimii akkutilassa. Varmista uusien akkujen olevan määrältään ja tyypiltään samat kuin alkuperäiset UPSakut. Katso tarkemmat ohjeet UPS:stä. Irrota ennen akkuliittimien kytkemistä tai irrotusta latauslähde avaamalla vastaava akkuvirtapiirin katkaisija. Määritä, onko akku maadoitettu tahattomasti. Jos näin on, irrota maalähde. Maadoitetun akun mihinkään osaan koskeminen voi aiheuttaa sähköiskun vaaran. Hävitä akut paikallisten hävitysvaatimusten mukaisesti. Älä hävitä akkuja polttamalla. Akut saattavat räjähtää avotulelle altistuneena. Tulipalovaaran pienentämiseksi laitteet saa liittää vain virtapiiriin, jonka syöttövirtapiirikatkaisijan nimellisvirta on kansallisten ja paikallisten asennusmääräysten mukainen. Varmista asianmukainen jäähdytysilmavirtaus ja henkilöstön suojaus vaarallisilta jännitteiltä UPS:n sisällä pitämällä laitteen ovi suljettuna ja etupaneelit asennettuna. Älä asenna UPS-järjestelmää kaasulla tai sähköllä tuotettujen lämmönlähteiden lähelle tai käytä sitä niiden lähellä. Pidä toimintaympäristö tässä asiakirjassa määritettyjen parametrien puitteissa. Pidä UPS:n ympäristö siistinä ja puhtaana, äläkä päästä ylimääräistä kosteutta kertymään. Huomioi kaikki VAARA-, HUOMAUTUS- ja VAROITUS-merkinnät, jotka on kiinnitetty laitteen sisä- tai ulkopuolelle. 33 2 Eaton® 91PS/93PS keskeytymätön sähkönsyöttö (uninterruptible power supply – UPS) on todellinen jatkuvasti toimiva, muuntajaton, kaksoismuuntava, puolijohtein toteutettu yksi(91PS) tai kolmivaiheinen (93PS) online-järjestelmä. Se syöttää vakioitua ja keskeytymätöntä vaihtovirtaa kriittiseen kuormaan ja suojaa sitä sähkökatkoksilta. Eaton 91/93PS:n lähtötehot perustuvat 15 kW:n tai 20 kW:n nimellistehon keskeytymättömän sähkönsyötön tehomoduuleihin (UPM:iin). 91PS/93PS on saatavilla myös C-mallina, joka sisältää 91PS/93PS UPS 15/20 kW:n kehikon sähköiset osat ilman akkuosastoa. FI Taulukko 1. UPS-kaapin teholuokitus UPS-kehikko Kuva (Piirustus 1) UPM-kaappien määrä Tehot 91PS 15 kW A ja B 1 8, 10, 15 kW 91PS 30 kW C 1 tai 2 8, 10, 15, 20, 30 kW 93PS 20 kW A ja B 1 8, 10, 15 tai 20 kW 93PS 40 kW C 1 tai 2 8, 10, 15, 20, 30 tai 40 kW 91PS/93PS UPS 8-40 kW:n laitteen pääosat on näytetty kuvassa 2. Pääosat ovat seuraavat: 1. 2. 3. 4. 5. 6. 7. 8. Ohjauspaneeli Oven salpa Tehomoduuli (UPM) Sisäinen akku (ei C-malleissa) . Tietoliikennealue Tulokytkin Akun katkaisija Huolto-ohituskytkin (valinnainen) VAARA UPS:ssä on hengenvaarallisia jännitteitä. Työt UPS:n sisäpuolella saa suorittaa vain valtuutettu Eatonin asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltohenkilöstö. UPS:n sisällä ei ole käyttäjän huollettavissa olevia osia. Katso täydelliset turvallisuusohjeet Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. UPS on asennettava Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaan suositusten mukaisesti. Käytä seuraavia vaiheita UPS:n asentamiseksi: 34 1. 2. 3. 4. 5. 6. Luo asennussuunnitelma UPS-järjestelmälle. Valmistele asennuspaikka UPS-järjestelmää varten. Tarkasta UPS-kaappi ja pura pakkaus. Pura UPS-kaappi lavalta ja asenna se sekä järjestelmän johdot. Täydennä asennustarkistuslista. Anna valtuutetun huoltohenkilökunnan suorittaa ensitoimintatarkastukset ja käyttöönotto. HUOMAA: Käynnistys- ja toimintatarkistukset saa suorittaa vain valtuutettu Eaton asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltohenkilöstö. Muussa tapauksessa Takuussa määritetyt takuuehdot eivät ole voimassa. FI Ennen UPS-järjestelmän asentamista on luettava ja ymmärrettävä, kuinka näitä ohjeita käytetään asennettavassa järjestelmässä. Käytä kuvattuja menettelytapoja ja kuvia laatiaksesi loogisen suunnitelman järjestelmän asennusta varten. Jotta UPS-järjestelmä toimisi huipputehollaan, asennuspaikan on vastattava Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaassa kuvattuja ympäristöä koskevia parametreja. Asennusympäristön on täytettävä taulukoissa 2 ja 3 annetut UPS:n paino- ja kokovaatimukset. UPS-kaapin mitat on näytetty kuvassa 1. Huomaa, että syvyysmitta (750 mm) sisältää kaapeliholkit. Taulukko 2. UPS-kaapin painot pahvipakkauksen kanssa C-malli 8-20 kW (Piirustus 1, kuva A) 15/20 kW:n kehikko* (Piirustus 1, kuva B) 30/40 kW:n kehikko* (Piirustus 1, kuva C) Toimituspaino 98 kg 293 kg 558 kg Asennuspaino 86 kg 280 kg 532 kg 310 kg/m2 1107 kg/m2 1478 kg/m2 Lattian kuormitus * Enimmäismäärä sisäisiä akkuja on mukana kaikissa malleissa. UPS-kaapeissa on oltava ilmanjäähdytin, jotta sisäisten komponenttien lämpötilaa voidaan säätää. Ilman tuloaukot ovat tavallisesti kaapin etuosassa ja poistoaukot takapuolella, katso kuva 3. Kunkin kaapin edessä ja yläpuolella on oltava tyhjää tilaa, jotta ilma pääsee vapaasti kiertämään. Varmista, ettei UPS:ään menevän ilman lämpötila ylitä arvoa +40 °C. Katso tuuletusvaatimukset Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. 35 Taulukko 3. UPS-kaapin ympärille vaadittu vähimmäistila 15/20 kW:n kehikko (Piirustus 1, kuvat A ja B) 30/40 kW:n kehikko (Piirustus 1, kuva C) Kaapin yläpuoli 500 mm 500 mm Kaapin etupuoli 500 mm 650 mm Kaapin takapuoli 150 mm 250 mm 0 mm 0 mm Kaapin sivu FI UPS-järjestelmän käytön suositeltu ympäristölämpötila ja kosteus on esitetty kuvissa 4.1 ja 4.2. VRLA-akkujen käyttöiän maksimoimiseksi ympäristön lämpötilaksi suositellaan +20 °C - +25 °C. Taulukko 4. Suositellut moniydinkaapelien ja sulakkeiden vähimmäiskoot tasasuuntaaja- ja ohitustulolle sekä UPS-lähtökaapeleille (kolmivaihetulo, kolmivaihelähtö) 93PS UPS:n teholuokitus (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Tasasuuntaajan sulake [A] 20 20 32 40 63 80 Ohituksen sulake [A] 20 20 32 40 63 80 PE-kaapeli [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kaapeli [mm2] Johtimen enimmäispoikkipinta-ala 20 kW:n kehikko ja 20 kW:n C-malli: säikeetön johto 16 mm2, punottu johto pääteliittimellä: 10 mm2 40kW:n kehikko ja 20 kW:n C-malli: säikeetön johto 70 mm2, punottu johto pääteliittimellä: 50 mm2 Taulukko 5. Suositellut moniydinkaapelien ja sulakkeiden vähimmäiskoot tasasuuntaaja- ja ohitustulolle sekä UPS-lähtökaapeleille (kolmivaihetulo, yksivaihelähtö) 91PS UPS:n teholuokitus (kW) 8 10 15 20 30 Tasasuuntaajan kaapeli [mm2]* 2,5 4 10 10 16 Tasasuuntaajan sulake [A] 20 20 32 40 63 Ohitus, lähtökaapeli [mm2] 10 16 25 35 70 Ohituksen sulake [A] 50 63 80 100 160 PE-kaapeli [mm2] 10 16 16 16 35 Johtimen enimmäispoikkipinta-ala, 15 kW:n kehikko ja 15 kW:n C-malli 36 Tasasuuntaaja: säikeetön johto 16 mm 2, punottu johto pääteliittimellä: 10 mm 2 Ohitus/lähtö: säikeetön johto 70 mm 2, punottu johto pääteliittimellä: 50 mm2 91PS UPS:n teholuokitus (kW) 8 Johtimen enimmäispoikkipinta-ala, 30 kW:n kehikko 10 15 20 30 Tasasuuntaaja: säikeetön johto 70 mm 2, punottu johto pääteliittimellä: 50 mm 2 Ohitus/lähtö: säikeetön johto 95 mm 2, punottu johto pääteliittimellä: 95 mm2 HUOMAUTUS Varmista, että UPS-järjestelmän tuloliittimien mahdollinen oikosulkuvirta ei ylitä järjestelmän tyyppikilvessä ilmoitettua ehdollista oikosulkuvirtaa. Taulukko 6. Ulkoisen akuston suositellut kaapelin ja sulakkeen vähimmäiskoot FI UPS-teholuokitus (kW) 8 10 15 20 30 40 Pos. ja neg. linja [mm2] 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Akun sulake [A] PE-kaapeli [mm2] Johtimen enimmäispoikkipinta-ala 15/20 kW:n kehikko, C-malli ja 30/40 kW:n kehikko erillisellä akulla: säikeetön johto: 25 mm2, punottu johto pääteliittimellä: 16 mm 2 30/40 kW:n kehikko yleisakulla: säikeetön johto: 90 mm 2, punottu johto pääteliittimellä: 70 mm2 Katso nimellis- ja enimmäisvirtatiedot nimellisteholla ja -jännitteellä Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. Ulkoisessa erillisessä akkuvaihtoehdossa on kaksi erillistä liitintä molemmille akustoille (kaapeille), katso lukua 2.3.1. HUOMAA: Tämän tuotteen mukana ei toimiteta ulkoista ylivirtasuojaa, mutta sellainen on sääntöjen mukaan pakollinen. Katso johdotusvaatimukset kohdasta Taulukko 4 ja 5. Mahdollisesti tarvittavan lukittavan lähtökatkaisulaitteen toimittaa käyttäjä. Taulukko 7. UPS-virtakaapeliliittimien kiristysmomentit UPS-kehikko Toiminto Kiristysmomentti Nm 93PS 20 kW X1, X2, X3: L1, L2, L3, N 1.6 X4: akku +/PE (maa) 93PS 40 kW 91PS 15 kW 3 10 Nm 16-35 mm2 johtoon 6 Nm 4-10 mm2 johtoon 4 Nm 2,5 mm2 johtoon X1, X2, X3: L1, L2, L3, N 6 X4: akku +/- 6 PE (maa) 10 Nm 16-35 mm2 johtoon 6 Nm 4-10 mm2 johtoon 4 Nm 2,5 mm2 johtoon X1 1.6 37 UPS-kehikko Toiminto Kiristysmomentti Nm X2, X3 7 X4 3 PE (maa) 10 Nm 16-35 mm2 johtoon 6 Nm 4-10 mm2 johtoon 4 Nm 2,5 mm2 johtoon X1 6 X2, X3 17 X4 6 91PS 30 kW PE (maa) FI 7 Nm (X1, X2, X3) 3.5 Nm (X4) Toimi Kaikki pakkausmateriaalit ja pidikkeet on poistettu kustakin kaapista. Jokainen kaappi UPS-järjestelmässä on sijoitettu asennuspaikkaansa. Kaapin maadoitus-/asennussarja on asennettu minkä tahansa kahden toisiinsa pultein kiinnitetyn kaapin väliin. Kaikki johdot ja kaapelit on asianmukaisesti reititetty UPS:ään ja mahdollisiin lisäkaappeihin. Kaikki virtajohdot on asianmukaisesti mitoitettu ja liitetty. Nollajohtimet on asennettu tai liitetty maahan vaatimusten mukaisesti. Maadoitusjohto on asennettu asianmukaisesti. Akkukaapelit on liitetty ja kytketty akun liittimiin. Akun rinnakkaislaukaisimen ja Aux (lisälaite) -koskettimen signaalijohdot on liitetty UPS:stä akkukatkaisijaan. LAN-haarajohdot on asennettu. Kaikki LAN-liitännät on tehty. Ilmastointivarusteet on asennettu, ja ne toimivat asianmukaisesti. Alue ja asennettu UPS-järjestelmä ovat puhtaat ja pölyttömät (UPS:n asennus suositellaan tehtäväksi vaakasuoralle tietokoneille ja elektronisille laitteille sopivalle lattialle). UPS:n ja muiden kaappien ympärillä on riittävä työtila. Kaikkien UPS:ien ympärillä on riittävä valaistus. 230 V:n vaihtovirtahuoltopistorasia on sijoitettu enintään 7,5 metrin päähän UPS:stä. Etähätäpysäytyskytkin (REPO-kytkin) on asennettu sille tarkoitettuun paikkaan, ja sen johdot on liitetty UPS-kaapin sisäpuolelle. Jos hätäpysäytyskytkintä (EPO) käytetään NC-kokoonpanossa, hyppyjohdin on asennettu EPO-nastojen 1 ja 2 välille. (VALINNAINEN) Hälytysreleiden ja signaalilähtöjen johdot on asennettu asianmukaisesti. (VALINNAINEN) Akun etäirrotusohjaus on kiinnitetty ja asennettu sille tarkoitettuun paikkaan, ja sen johdot on liitetty UPS- ja akkukaapin sisäpuolelle. (VALINNAINEN) Lisävarusteet on asennettu niille tarkoitettuihin paikkoihin, ja niiden johdot on liitetty UPS-kaapin sisäpuolelle. Käynnistys- ja toimintatarkistukset on suorittanut valtuutettu Eaton asiakaspalveluinsinööri tai Eatonin valtuuttama pätevä huoltoinsinööri. 38 Kyllä/Ei UPS:n pakkauksesta ja lavalta poistaminen on näytetty kuvissa 9.1-9.8. Tarkista ennen UPS:n pakkauksesta ja lavalta poistamisen aloittamista TipNTell- ja DropNTell-osoitin pakkauksen pinnalla. Jos laite on kuljetettu oikein pystyasennossa, osoitin on muuttumaton. Jos TipNTell-osoitinnuoli on kokonaan sininen tai DropNTellosoittimen nuolen pää(t) on/ovat musta(t), ota yhteys asianomaisiin osapuoliin epäasiallisen kuljetuksen raportoimiseksi. UPS-kaappi on pultattu puulavaan kuljetusta varten. Ennen kuin poistat kaapin lavalta, käytä trukkia tai muuta tavarankäsittelylaitetta kaapin siirtämiseen asennusalueelle. VAROITUS FI UPS-kaappi on painava. Jos pakkauksen purkamiseen liittyviä ohjeita ei noudateta tarkasti, kaappi saattaa keikahtaa kumoon ja aiheuttaa vakavia loukkaantumisia. Älä kallista UPS-kaappia yli 10° pystysuorasta asennosta tai kaappi saattaa kaatua. HUOMAA: Kun olet poistanut kuljetuskiinnittimet, siirrä yksikkö välittömästi pois kuormalavalta. Kun olet poistanut kuljetuskiinnittimet ja vetänyt tasausjalat sisään, älä käytä trukkia yksikön siirtämiseen sen ollessa edelleen kuormalavalla. Huomaa, että UPS:n kaappi on raskas ja sen alla on pyörät. Jos kaappi otetaan pois alkuperäisestä asennuspaikastaan ja siirretään uuteen sijaintiin kuormalavalla, laske tasausjalkoja, kunnes kaappi ei ole enää pyörien varassa ja kiinnitä kuljetuskiinnittimet kaappiin ja kuormalavaan. Asiakkaan on toimitettava johdot UPS:n liittämiseksi paikalliseen virtalähteeseen. Paikallisen pätevän sähköasentajan on suoritettava UPS:n asennus. Asennustarkastus ja UPS:n ensikäyttöönotto samoin kuin lisäakkukaapin asennus on annettava valtuutetun Eaton asiakaspalveluinsinöörin tai Eatonin valtuuttaman huoltohenkilöstön suoritettavaksi. UPS:n asennus on näytetty kuvissa 10.1-10.5. UPS:n virtakaapeliliittimet on näytetty kuvissa 6.1 (91PS 15 kW:n kehikko), 6.2 (93PS 20 kW:n kehikko), 7.1 (91PS 30kW:n kehikko yleisakun kanssa), 7.2 (91PS 30kW:n kehikko erillisen akun kanssa), 8.1 (93PS 40kW:n kehikko yleisakun kanssa) ja 8.2 (93PS 40kW:n kehikko erillisen akun kanssa). X1 X2 X3 X4/+ UPM2 Tasasuuntaajan tulo Ohituksen tulo UPS-lähtö Ulkoinen akku + (erillinen akku) X4/TB20 TB21 PE Ulkoinen akku Ulkoinen akkukatkaisija Ulkoinen akkukatkaisija Suojamaadoitus 39 UPS:n tietoliikenneliittimet on näytetty kuvissa 5.1 ja 5.2. Liittimet ovat seuraavat: 1. 2. 3. 4. 5. 6. TB11, ei käytössä TB10, ei käytössä TB9, ei käytössä TB8, ulkoinen CANliitäntä TB7, ulkoinen CAN TB6, tilatietoväylä 7. USB1, USB-isäntä (liitäntä lisävarusteisiin) 8. USB2, USB-laite (liitäntä tietokoneeseen) 9. MiniSlot 1 10. TB1, signaalitulo 1-5 11. 12. 13. 14. 15. 16. TB2, ei käytössä TB3, ei käytössä COM-sarjaportti RS-232 MiniSlot 2 TB4, EPO TB5, relelähtö Jos asennat asiakkaan toimittamaa akkujärjestelmää, asenna akkujärjestelmä akun ja akkujärjestelmän valmistajan ohjeiden ja kaikkien soveltuvien kansallisten asennussääntöjen ja määräysten mukaisesti. FI Katso akun tekniset tiedot Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. 91PS/93PS 8-40 kW:n UPS-yksiköt on aina varustettu sisäisellä akkukatkaisijalla, joka vaikuttaa vain UPS:n sisäisiin akkuihin (paitsi C-malli, jossa sisäistä akkukatkaisijaa voidaan käyttää ulkoisiin akkuihin). Ulkoinen akkukatkaisija on olennaisen tärkeä osa ulkoista akkukaappia tai telinettä ja se on sijoitettava siihen. Signaalikaapelointi on tärkeää ulkoisen akkukatkaisijan kanssa. Sekä sisäinen että ulkoinen akkukatkaisija voidaan laukaista (laittaa pois päältä) virroittamalla sen rinnakkaislaukaisukela. Ulkoisten akkukatkaisijoiden rinnakkaislaukaisukelat virroitetaan (ohjataan) liittimien TB20 ja TB21 läpi (TB21 saatavissa vain 8-40 kW UPS:sä erillisellä akkukonfiguraatiolla). Rinnakkaislaukaisukelan oletusjännite on 24 VDC. Akkulaukaisun johdotus on näytetty kuvassa 11. Osat ovat seuraavat: A 1 2 Ulkoinen akkukatkaisija Nasta 1, rinnakkaislaukaisukela + Nasta 2, rinnakkaislaukaisukela - 3 4 Nasta 3, AUX-kontakti Nasta 4, AUX-kontakti, paluu Katso ulkoisen akkukaapin ja akkujen virtakaapeloinnin asennusohjeet Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta ja ulkoisen akkukaapin mukana toimitetusta ohjekirjasta. Maadoita ulkoinen akkukaappi / asiakkaan toimittama akkujärjestelmä PEliittimeen 17. EPO on liitettävä UPS:n yläetupaneelin EPO-liittimeen. EPO-kytkimen liitännät on näytetty kuvassa 12. Katso liitäntäkytkentöjen asennustiedot Eaton 91PS/93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. UPS:n standardiominaisuutena on yksi relekontakti yleistarkoitukseen. Lisäksi on saatavissa hälytyskosketin. Relelähtökonfiguraatiot on näytetty kuvassa 13. 40 Sekä normaalisti auki olevan että normaalisti kiinni olevan koskettimen käyttö on mahdollista. Jos koskettimen tila muuttuu normaaliksi määrittämästäsi tilasta, lähetetään signaali. Voit yhdistää tämän koskettimen tiloissasi oleviin laitteistoihin (kuten valoon tai hälytyssummeriin), jotta tiedät, kun UPS-hälytys on aktiivinen. HUOMAA: Koskettimia käytettäessä 30 VAC (RMS) ja 30 VDC 5 A:n virralla eivät saa ylittyä. Katso 91PS/93PS UPS rinnakkaisjärjestelmien johdotustiedot Eaton 93PS UPS 8-40 kW:n käyttö- ja asennusoppaasta. FI 41 1 FARA Viktiga säkerhetsanvisningar! Spara dessa instruktioner! Detta dokument förser dig med viktiga säkerhetsinstruktioner och en kort instruktion för hur du undersöker UPS-leveransen och hur man installerar UPS:en. Denna snabbguide är endast avsedd att användas som en installationschecklista på plats. Dokumentets avsedda målgrupp är erfarna medarbetare som planerar och genomför installationen av UPS:en. FARA SV Innan du arbetar med UPS:en, läs igenom de fullständiga installationsinstruktionerna som återfinns i Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. Fullständiga instruktioner kan laddas ner från www.eaton.com/91psand93ps. Förfaranden inuti UPS:en måste utföras av behörig servicetekniker från Eaton eller behörig servicepersonal auktoriserad av Eaton. Det finns inga delar i UPS:en som användaren själv kan utföra service på. UPS:en drivs med nätström, batteri, eller förbikopplad kraft. Den innehåller komponenter som innehåller starkström och högspänning. Ett korrekt installerat hölje är jordat IP20graderat mot elektriska stötar och främmande föremål. Men UPS:en är ett sofistikerat kraftsystem och endast behörig personal får installera och serva UPS:en. FARA Denna UPS-enhet leder dödlig spänning. Batterier innebär risk för elstötar och brännskador från hög kortslutningsström. Följ säkerhetsföreskrifterna. Batterier kan innehålla HÖG SPÄNNING eller FRÄTANDE, GIFTIGA, och EXPLOSIVA ämnen. På grund av batteristrängen kan utgående strömuttag bära hög spänning även när AC-försörjningen inte är ansluten till UPS:en. Läs igenom nedstäningsinstruktionerna i Användar- och Installationsguiden. VARNING UPS:en drivs med en egen energikälla (batterier). Utgångsterminalerna kan vara spänningsförande även när UPS:en inte är ansluten till någon växelströmskälla. Reducera risken för brand eller elstötar genom att installera UPS:en i en inomhusmiljö med kontrollerad temperatur och luftfuktighet, fri från ledande föroreningar. Stapla inte UPS 91PS/93PS C-modell på några andra liknande skåp. Stapla ingenting ovanpå 91PS/93PS UPS-skåpet. Om UPS 91PS/93PS C-modell installeras på en hylla, använd nödvändiga stöd för att förhindra att UPS:en välter. 42 VARNING Omgivningstemperaturen får inte överstiga 40 °C. Använd ej UPS:en i närheten av vatten eller hög fuktighet (maximalt 95 %). Systemet är inte avsett för utomhusbruk. Innan du påbörjar installations- eller servicearbete, se till att alla AC- och DC-strömkällor är frånkopplade. Ström kan komma från flera olika källor. Försäkra dig även om systemjord / PE-kontinuitet. I parallellkopplade system kan utgångsterminalerna vara strömförande även när UPS:en är avstängd. Elenergifara. För att undvika skada, ändra inte batteriets sladdar eller anslutningar. OBS: Se till att du kopplar ifrån alla batteristrängar innan installation. FÖRSIKTIGHET Endast behörig servicepersonal med kunskap om batterier och nödvändiga försiktighetsåtgärder får utföra installation eller servicearbete på batterierna. Installationoch servicearbete på batterier är arbete med strömförande ledningar och kräver användning av spänningsverktyg. Håll obehörig personal borta från batterierna. Innan du installerar eller byter batterier, tänk på alla varningar, försiktighetsåtgärder och anmärkningar gällande lämplig hantering. Koppla inte ur batterierna medan UPS:en är i batteriläget. Se till att dina ersättningsbatterier är av samma antal och typ som batteriet som installerades i UPS:en från början. Se mer noggranna instruktioner på UPS:en. Innan du ansluter eller kopplar ifrån batteriterminaler, koppla ifrån laddningskällan genom att öppna motsvarande batteribrytare. Undersök om batteriet har jordats av misstag. Om det är jordat, kopplar du bort jordkabeln. Kontakt med någon del av ett jordat batteri kan innebära risk för elstötar. Kasta batterier i enlighet med lokala krav för bortskaffning. Kasta aldrig batterier i eld. När de utsätts för eld, kan batterier explodera. För att minska risken för brand ska du bara ansluta till en krets med ingångskretsbrytare klassificerade för maximal ström i enlighet med nationella och lokala installationsbestämmelser. För att försäkra ordentligt kylluftflöde och för att skydda personal från farlig spänning inuti enheten, håll UPS-dörren stäng och frontpanelerna installerade. UPS-systemet får inte installeras eller användas i närheten av gas- eller elvärmekällor. Håll driftmiljön inom parametrarna angivna i detta dokument. UPS:ens omgivningen ska vara obelamrad, ren, och fri från hög fuktighet. Följ all FARA-, FÖRSIKTIGHET- och VARNING-text som återfinns på insidan och utsidan av utrustningen. 43 SV 2 Eaton® 91PS/93PS avbrottsfria strömförsörjning (UPS) är ett verkligt online, driftssäkert, transformatorlöst, dubbelkonverterat, stabilt, enfas- (91PS) eller trefassystem (93PS). Det ger konditionerad och oavbruten växelström till den kritiska lasten och skyddar den mot strömavbrott. Den nominella uteffekten för Eaton 91PS/93PS är baserad på avbrottsfria kraftmoduler (UPM) med en märkeffekt på 15 kW eller 20 kW. 91PS/93PS finns också som C-modell, vilken består av de elektriska komponenterna från 91PS/93PS UPS 15/20 kW-ramen utan batteriutrymmet. Tabell 1. UPS-skåpets märkeffekt UPS-ram SV Bild (Illustration 1) Antal UPM-enheter Märkeffekt 91PS 15 kW A och B 1 8, 10, 15 kW 91PS 30 kW C 1 eller 2 8, 10, 15, 20, 30 kW 93PS 20 kW A och B 1 8, 10, 15 eller 20 kW 93PS 40 kW C 1 eller 2 8, 10, 15, 20, 30 eller 40 kW Huvuddelarna i 91PS/93PS UPS 8-40 kW visas i illustration 2. Huvuddelarna är följande: 1. 2. 3. 4. Kontrollpanel Dörrlås Effektmodul (UPM) Internt batteri (ej i C-modeller) . 5. 6. 7. 8. Kommunikationsområde Ingångsbrytare Batteribrytare Serviceförbikoppling (tillval) FARA Denna UPS-enhet leder dödlig spänning. Förfaranden inuti UPS:en måste utföras av behörig servicetekniker från Eaton eller behörig servicepersonal auktoriserad av Eaton. Det finns inga delar i UPS:en som användaren själv kan utföra service på. För fullständiga säkerhetsinstruktioner, se Eaton 91PS/93PS UPS 8-40 kW Användaroch Installationsguide. UPS:en måste installeras enligt rekommendationerna i Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. Installera UPS:en via följande grundläggande steg: 44 1. 2. 3. 4. 5. 6. Upprätta en installationsplan för UPS-systemet. Förbered en plats för UPS-systemet. Inspektera och packa upp UPS:en. Packa upp och installera UPS:en, och koppla in kablarna till systemet. Fyll i installationschecklistan. Låt auktoriserad servicepersonal utföra den preliminära driftskontrollen och starten. ANMÄRKNING: Igångsättning och driftskontroller måste utföras av en auktoriserad servicetekniker från Eaton eller behörig servicepersonal auktoriserad av Eaton, annars blir garantivillkoren som specificeras i Garantin ogiltiga. Läs och förstå hur dessa instruktioner tillämpas på systemet som ska installeras innan du installerar UPS-systemet. Använd försedda procedurer och illustrationer för att skapa en logisk plan för installationen av systemet. SV För att UPS-systemet ska fungera effektivast ska installationsplatsen uppfylla miljöparametrarna som anges i Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. Installationsplatsen måste uppfylla UPS vikt- och storlekskraven som anges i Tabellerna 2 och 3. Dimensionerna för UPS-skåpet visas i illustration 1. Observera att djupdimensionen (750 mm) inkluderar kabelgenomföringar. Tabell 2. UPS-skåp vikt med kartongförpackning C-modell 8-20 kW (Illustration 1, bild A) 15/20 kW-ram* (Illustration 1, bild B) 30/40 kW-ram* (Illustration 1, bild C) Transportvikt 98 kg 293 kg 558 kg Installerad vikt 86 kg 280 kg 532 kg Golvbelastning 310 kg/m2 1107 kg/m2 1478 kg/m2 * Maximala interna batterier levereras med alla modeller. UPS:en använder forcerad luftkylning för reglering av de inre komponenternas temperatur. Som standard sitter luftintagen framtill på enheten och utgångarna på ovansidan, se illustration 3. Lämna fritt utrymme för ordentlig luftcirkulation framför och bakom enheten. Se till att kylluften som kommer in i UPS:en inte överskrider +40 °C. För ventilationskrav, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. 45 Tabell 3. Minsta spelrum för UPS-skåpet 15/20 kW-ram (Illustration 1, bild A och B) 30/40 kW-ram (Illustration 1, bild C) Från skåpets topp 500 mm 500 mm Från skåpets framsida 500 mm 650 mm Från skåpets baksida 150 mm 250 mm 0 mm 0 mm Från skåpets sida Rekommenderad omgivande driftstemperatur och luftfuktighet för UPS-systemet visas i illustration 4.1 and 4.2. En omgivningstemp från +20 °C till +25 °C rekommenderas för att ge VRLA-batterierna en lång livstid. SV Tabell 4. Minsta rekommenderade storlek för flerledarkabel och säkringar till likriktare och förbikopplingsingång och UPS-utgångskablar (trefasingång, trefasutgång) 93PS UPS märkeffekt (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Likriktare säkring [A] 20 20 32 40 63 80 Förbikoppling säkring [A] 20 20 32 40 63 80 PE-kabel [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] Maximal ledararea 20 kW-ram och 20 kW C-modell: solidtråd 16mm2, tvinnad tråd med hylsa: 10 mm2 40kW-ram: solidtråd 70 mm2, tvinnad tråd med hylsa: 50 mm2 Tabell 5. Minsta rekommenderade storlek för flerledarkabel och säkringar till likriktare och förbikopplingsingång och UPS-utgångskablar (trefasingång, enfasutgång) 91PS UPS märkeffekt (kW) 8 10 15 20 30 Likriktare kabel [mm2] 2,5 4 10 10 16 Likriktare säkring [A] 20 20 32 40 63 Förbiledning, utgångskabel [mm2] 10 16 25 35 70 Förbikoppling säkring [A] 50 63 80 100 160 PE-kabel [mm2] 10 16 16 16 35 Maximal ledararea, 15 kW ram och 15 kW C-modell 46 Likriktare: solidtråd 16 mm2, tvinnad tråd med hylsa: 10 mm2 Förbiledning/utgång: solidtråd 70 mm2, tvinnad tråd med hylsa: 50 mm2 91PS UPS märkeffekt (kW) Maximal ledararea, 30 kW ram 8 10 15 20 30 Likriktare: solidtråd 70 mm2, tvinnad tråd med hylsa: 50 mm2 Förbiledning/utgång: solidtråd 95 mm2, tvinnad tråd med hylsa: 95 mm2 FÖRSIKTIGHET Se till att prospektiv kortslutningsström som leder till UPS:ens ingångar är lika med eller mindre än villkorlig kortslutningsströmmen angiven på UPS:ens typskylt. Tabell 6. Minsta rekommenderade kabel- och säkringsstorlek för extern batteribank UPS klassificering (kW) Pos. & neg. ledning [mm2] Batterisäkring [A] PE-kabel [mm2] Maximal ledararea 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 15/20 kW-ram, C-modell och 30/40 kW-ram med separat batteri: solidtråd: 25 mm2, tvinnad tråd med hylsa: 16 mm2 30/40 kW-ram med vanligt batteri: solidtråd: 90 mm2, tvinnad tråd med hylsa: 70 mm2 För information om märk- och max-ström för märkeffekt och -spänning, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. För de externa separata batterierna finns det separata terminaler för båda batteribankerna (skåp), se Avsnitt 2.3.1. ANMÄRKNING: Externt överspänningsskydd ingår inte i den här produkten, men krävs enligt bestämmelser. Se Tabellerna 4 och 5 för krav på kablar. Om en låsbar utgångsfrånkoppling krävs ska den tillhandahållas av användaren. Tabell 7. UPS-strömkabel terminal moment UPS-ram 93PS 20 kW Funktion Åtdragningsmoment Nm X1, X2, X3: L1, L2, L3, N 1.6 X4: batteri +/PE (jord) 93PS 40 kW 91PS 15 kW 3 10 Nm för 16-35 mm2 kabel 6 Nm för 4-10 mm2 kabel 4 Nm för 2,5 mm2 kabel X1, X2, X3: L1, L2, L3, N 6 X4: batteri +/- 6 PE (jord) 10 Nm för 16-35 mm2 kabel 6 Nm för 4-10 mm2 kabel 4 Nm för 2,5 mm2 kabel X1 1.6 47 SV UPS-ram 91PS 30 kW SV Funktion Åtdragningsmoment Nm X2, X3 7 X4 3 PE (jord) 10 Nm för 16-35 mm2 kabel 6 Nm för 4-10 mm2 kabel 4 Nm för 2,5 mm2 kabel X1 6 X2, X3 17 X4 6 PE (jord) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Handling Allt förpackningsmaterial och alla fasthållningsanordningar har tagits bort från enheterna. UPS-systemets enheter har placerats på installationsplatserna. En jordnings-/monteringssats för enheten har installerats mellan enheterna som satts ihop. Alla ledningar och kablar har dragits korrekt till UPS:en och alla extra-enheter. Alla strömkablar är korrekt dimensionerade och anslutna. Nolledare har installerats och anslutits till jord i enlighet med kraven. En jordledare har installerats korrekt. Batterikablarna är anslutna till batteriets kontakter. Shuntfrånkoppling för batteri och Aux-kontaktsignalkabeln är anslutna från UPS:en till batteribrytaren. Nätverksanslutningarna har installerats. Alla LAN-anslutningar är slutförda. Luftkonditioneringsutrustning har installerats och fungerar korrekt. Området kring det installerade UPS-systemet är rent och dammfritt (det är rekommenderat att installera UPS:en på ett platå lämplig för dator- eller elektronisk utrustning). Det finns tillräckligt med arbetsutrymme kring UPS:en och övriga enheter. UPS-utrustningen omges av tillräcklig belysning. Ett 230 VAC-uttag är placerad inom 7,5 meter från UPS-utrustningen. Fjärrnedstängning vid nödläge (REPO) är monterad på dess installationsplats och dess kablar har dragits till UPS:en. Om EPO används i NC-konfigurationen, installeras en jumper på EPO:n mellan stift 1 och 2. (TILLVAL) Larmreläer och signalutgångar är korrekt inkopplade. (TILLVAL) Kontrollen för fjärrnedstängning av batteri är monterad på dess installationsplats och dess kablar har dragits till UPS:en och batterienheten. (TILLVAL) Tillbehör har monterats på sin installationsplats och kablarna har dragits till UPS:en. Igångsättning och driftskontroller UPS:en utförs av en behörig Eaton Kundtjänst-tekniker eller behörig servicetekniker, auktoriserade av Eaton. 48 Ja/Nej Uppackning och avlastning av UPS:en visas i illustration 9.1–9.8. Innan du börjar packa upp UPS:en, kontrollera TipNTell / DropNTell-indikatorerna på paketets yta. Om utrustningen har transporterats i korrekt upprätt position bör indikatorerna vara intakta. Om TipNTell-indikatorpilen har blivit blå eller om pilhuvudet(ena) på DropNTell-indikatorn är svart, kontakta lämpliga parter att rapportera olämplig transport. För transportändamål är UPS-skåpet fastbultat på en träpall. Innan du lastar av skåpet från pallen, använd en gaffeltruck eller någon annan form av utrustning för materialhantering för att flytta skåpet till installationsplatsen. VARNING UPS:en är tung. Om uppackningsanvisningarna inte följs noggrant kan enheten välta och orsaka allvarliga personskador. Luta inte UPS:en mer än 10 grader från vertikal position, i annat fall kan enheten tippa. SV ANMÄRKNING: När du har tagit bort transportfästena, flytta direkt av enheten från pallen. När du har tagit bort transportfästena och dragit in fötterna, använd inte en gaffeltryck för att flytta enheten medan den står på pallen. Observera att UPS:en är tung och att det är hjul under skåpet. Om du tar bort skåpet från dess ursprungliga installationsplats och flyttar det till en ny plats på en pall, sänk ned fötterna så att skåpet inte vilar på hjulen och fäst transportkonsolerna på skåpet och pallen. Operatören ska tillhandahålla kablar för att ansluta UPS:en till den lokala strömkällan. Installationen av UPS:en måste genomföras av en lokalt behörig elektriker. Kontroll av installation och första drifttagning av UPS-enheten samt installation av ett extra batteriskåp måste utföras av behörig servicetekniker från Eaton eller behörig servicepersonal auktoriserad av Eaton. Installationen av UPS:en visas i illustration 10.1-10.5. UPS-enhetens strömkabelterminaler visas i illustration 6.1 (91PS 15 kW-ram), 6.2 (93PS 20 kW-ram), 7.1 (91PS 30kW-ram med ett vanligt batteri), 7.2 (91PS 30kW-ram med ett separat batterialternativ), 8.1 (93PS 40kW-ram med ett vanligt batteri) och 8.2 (93PS 40kW-ram med ett separat batterialternativ). X1 X2 Likriktaringång Förbikopplingsingång X4/TB20 X3 UPS-utgång TB21 X4/+ UPM2 Externt batteri + (separat batteri) PE Externt batteri Utlösning av extern batteribrytare Utlösning av extern batteribrytare Skyddsjord 49 UPS:ens kommunikationsterminaler visas i illustration 5.1 och 5.2. Terminalerna är enligt följande: 1. 2. 3. 4. 5. 6. TB11, används ej TB10, används ej TB9, används ej TB8, extern CANavslutning TB7, extern CAN TB6, dragbrytare buss 7. USB1, USB-värd (anslutning till tillbehör) 8. USB2, USB-enhet (anslutning till dator) 9. MiniSlot 1 10. TB1, signalingång 1-5 11. 12. 13. 14. 15. 16. TB2, används ej TB3, används ej Seriell COM-port RS-232 MiniSlot 2 TB4, EPO TB5, reläutgång Om ett batterisystem som tillhandahålls av kunden installeras, ska det installeras i enlighet med anvisningarna från batteriets och batterisystemets tillverkare samt alla relevanta föreskrifter och bestämmelser. För batterispecifikationer, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. SV 91PS/93PS 8-40 kW UPS-enheterna är alltid utrustade med en intern batteribrytare som endast påverkar UPS:ens interna batterier (förutom för C-modellen, där den interna batteribrytaren kan användas för externa batterier). Den externa batteribrytaren är en viktig del av det externa batteriskåpet eller racket och måste placeras i den. Med den externa batteribrytaren, är signalkablar är viktiga. Både interna och externa batteribrytare kan utlösas (stängas av) genom aktivering av dess shuntutlösningsspole. Shuntutlösspolar hos externa batteribrytare aktiveras (kontrolleras) genom kontakter TB20 och TB21 (TB21 finns endast i 8-40 kW UPS med separat batterikonfiguration). Standard spänning för shuntutlösningsspolen är 24 VDC. Batteriutlösning ledningar visas i illustration 11. Delarna är enligt följande: A 1 Extern batteribrytare Stift 1, shuntutlösspole + 2 Stift 2, shuntutlösspole - 3 4 Stift 3, AUX-kontakt Stift 4, AUX-kontakt återgång För instruktioner om hur du installerar externa batteriskåpet och batterikablage, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide och bruksanvisningen som medföljer externa batteriskåp. Jorda det externa batteriskåp / kund-medföljande batterisystemet till PE terminalen 17. EPO är ansluten till UPS:ens frontpanel, på kontakten EPO. Anslutningarna för EPOomkopplaren visas i illustration 12. För information om installation av anslutningar till gränssnittet, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. 50 En reläkontakt för allmänna ändamål är standard på UPS:en. Det finns också en larmkontakt. Relänas utgångskonfigurationer visas i illustration 13. Du kan välja en normalt sluten eller normalt öppen kontakt. En signal avges om kontaktens status ändras från statusen som du angav som normal. Du kan ansluta den här kontakten till utrustning i din fastighet (t.ex. en lampa eller akustisk larmfunktion) så kan du få reda på när ett larm aktiverats på UPS:en. ANMÄRKNING: Kontakter bör inte användas vid mer än maximalt 30 VAC (RMS) och 30 VDA vid högst 5 A. För information kabeldragning i parallella 91PS/93PS UPS-system, se Eaton 91PS/93PS UPS 8-40 kW Användar- och Installationsguide. SV 51 1 FARE Viktige sikkerhetsanvisninger! Ta vare på denne bruksanvisningen! Dette dokumentet inneholder viktige sikkerhetsanvisninger for hvordan du undersøker UPS-leveransen og hvordan UPS-en installeres. Denne hurtigveiledningen er bare ment å bli brukt som en installasjonssjekkliste på stedet. Det tiltenkte publikum av dette dokumentet er erfarne fagfolk som planlegger og utfører installasjonen av UPS-en. FARE Før du utfører arbeid på UPS-en, les alle installasjonsanvisningene som er inkludert i bruker- og installasjonsveiledningen for Eaton 91PS/93PS 8-40 kW UPS. De komplette anvisningene er tilgjengelige for nedlasting på www.eaton.com/91psand93ps. NO Operasjoner inne i UPS-en må gjøres av en autorisert servicetekniker fra Eaton eller av kvalifisert servicepersonell som er autorisert av Eaton. Ingen av de innvendige delene kan repareres av brukeren. UPS-en bruker strømnettet, batteri eller bypass-strøm. UPS-en inneholder komponenter som er ladet med høy strøm og spenning. Et korrekt montert skap er jordet og IP20klassifisert mot elektrisk støt og fremmedlegemer. Imidlertid er UPS-en en avansert strømkilde og skal kun installeres og repareres av kvalifisert personell. FARE Spenningen i UPS-en kan elektrisk støt med døden til følger. Batteriene utgjør risiko for elektrisk støt eller brannsår fra høye kortslutningsstrømmer. Følg forholdsreglene. Batterier kan ha HØYE SPENNINGER, og ETSENDE, GIFTIGE og EKSPLOSIVE stoffer. På grunn av batteristrengen, kan utgangsmottakerne bære høy spenning, selv når strømtilførselen ikke er koblet til UPS-en. Les nedstengingsinstruksjonene i bruker- og installasjonsveiledningen. ADVARSEL UPS-en har en egen kraftforsyning (batterier). Strømutgangen kan være strømsatt selv etter at UPS-en er koblet fra nettspenningen. For å redusere faren for brann eller elektrisk støt, bør UPS-en settes i et innemiljø som er temperatur- og fuktighetsregulert, og fritt for ledende kontaminasjoner. Ikke stable 91PS/93PS UPS C-modellskapet oppå noe/noen annet/andre lignende skap. Ikke stable noe oppå 91PS/93PS UPS-skapet. Hvis 91PS/93PS UPS C-modellskapet installeres på en hylle, må du bruke nødvendig støtte for å forhindre at UPS-en velter eller faller ned. 52 ADVARSEL Romtemperaturen må ikke overskride 40 °C. UPS-en må ikke brukes i nærheten vann eller i omgivelser med høy luftfuktighet (maks 95%). Enheten er ikke beregnet for utendørs bruk. Før det utføres installasjon eller service, må alle AC og DC-strømkilder være koblet fra. Flere kilder kan være strømsatt. Sjekk også systemets jording / PE-leder. I et parallelt system kan utgangene være strømsatt selv når UPS-en er slått av. Fare for elektrisk støt. For å unngå skade, ikke forsøk å gjøre endringer på batterikablene eller koblingene. VIKTIG: Pass på at du kobler fra alle batteristrengene før installasjon. FORSIKTIG Det er kun kvalifisert personell med kunnskap om batterier og relevante forholdsregler som kan utføre installasjon av eller service på batteriene. Installasjons- og servicearbeid på batterier er strømdrevet arbeid og krever bruk av spenningsverktøy. Uvedkommende må holdes borte fra batteriene. Før du installerer eller skifter batterier, må du ta i betraktning alle advarsler, forsiktighetsregler og merknader om forsvarlig håndtering. Ikke koble fra batteriene når UPS-en er i batterimodus. Påse at de nye batteriene er av samme antall og type som det originale batteriet i UPSen. Se detaljerte instruksjoner om UPS-en. Før du kobler til eller fra batteriterminalene, må ladekilden kobles med korresponderende batteribryter. Undersøk om batteriet er utilsiktet jordet. Hvis batteriet er jordet, må jordingspunktet kobles fra. Dersom du kommer i kontakt med et batteri som er jordet, kan det føre til elektrisk støt. Batteriene må avhendes i henhold til lokale avfallsforskrifter. Ikke kast batterier i brannkilder. Batterier kan eksplodere dersom de utsettes for flammer. For å redusere risikoen for brann, koble kun til en krets som er utstyrt med en inngangseffektbryter med høyeste nominell strøm i samsvar med nasjonale og lokale forskrifter for installasjon. For å sikre tilstrekkelig ventilasjon og for å beskytte personer fra farlige spenninger inne i enheten, må døren på UPS-en holdes lukket og frontpanelene være på plass. Ikke installer eller bruk UPS-systemet i nærheten av gass eller elektriske varmekilder. Driftsmiljøet må opprettholdes innenfor rammene som er beskrevet i dette dokumentet. Hold omgivelsene rundt UPS-en ryddige, rene og fri for fuktighet. All merking med FARE, FORSIKTIG og ADVARSEL på innsiden og utsiden av utstyret må følges. 53 NO 2 Eaton® 91PS/93PS avbruddsfri strømforsyning (UPS-enheten) er et ekte online, transformatorløs, dobbeltkonverterende, solid-state, enfaset (91PS) eller trefaset (93PS) system for kontinuerlig drift. Det leverer filtrert og avbruddsfri AC-strøm til kritisk last og beskytter den mot strømbrudd. Eaton 91PS/93PS utgangseffekt er basert på avbruddsfrie strømmoduler (UPM-er) med 15 kW eller 20 kW nominell effekt. 91PS/93PS er også tilgjengelig som en C-modell, som består av den elektriske delen av 91PS/93PS UPS 15/20 kW-rammen uten batterirommet. Tabell 1.Klassifiseringer for UPS-skapet NO UPS-ramme Bilde (Illustrasjon 1) Antall UPM-er Klassifiseringer 91PS 15 kW A og B 1 8, 10, 15 kW 91PS 30 kW C 1 eller 2 8, 10, 15, 20, 30 kW 93PS 20 kW A og B 1 8, 10, 15 eller 20 kW 93PS 40 kW C 1 eller 2 8, 10, 15, 20, 30 eller 40 kW Hoveddelene av 91PS/93PS UPS 8-40 kW er vist i illustrasjon 2. Hoveddelene er som følger: 1. 2. 3. 4. . Kontrollpanel Dørlås Strømmodul (UPM) Internt batteri (ikke i C-modeller) 5. 6. 7. 8. Kommunikasjonsseksjon Inngangsbryter Batteribryter Bypass-bryter (MBS) (valgfritt) FARE Spenningen i UPS-en kan elektrisk støt med døden til følger. Operasjoner inne i UPS-en må gjøres av en autorisert servicetekniker fra Eaton eller av kvalifisert servicepersonell som er autorisert av Eaton. Ingen av de innvendige delene kan repareres av brukeren. For komplette sikkerhetsanvisninger, se bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. UPS-en må installeres i henhold til anbefalingene i bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. Utfør følgende trinn i oppgitt rekkefølge for å installere UPS-systemet: 54 1. 2. 3. 4. 5. 6. Lag en installasjonsplan for UPS-systemet. Klargjør stedet der UPS-systemet skal installeres. Sjekk og pakk ut UPS-skapet. Ta ut og installer UPS-skapet og ledningsanlegget. Fullfør installasjonssjekklisten. Få autorisert servicepersonell til å utføre forberedende funksjonskontroll og idriftsettelse. MERK: Oppstart og operasjonelle kontroller må utføres av en autorisert Eatonservicetekniker eller kvalifisert servicepersonell som er autorisert av Eaton. Unnlatelse av å etterleve dette vil ugyldiggjøre garantibetingelsene spesifisert i garantien. Før UPS-systemet installeres, må du lese gjennom og være innforstått med hvordan disse instruksjonene anvendes for systemet som skal installeres. Bruk de medfølgende fremgangsmåtene og illustrasjonene for å utarbeide en logisk plan for installasjon av systemet. For at UPS-systemet skal kunne operere så effektivt som mulig, må installasjonsstedet oppfylle de miljømessige verdiene som er beskrevet i bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. Installasjonsmiljøet må oppfylle vekt- og størrelseskravene til UPS-en oppgitt i tabellene 2 og 3. Dimensjonene av UPS-skapet er vist i illustrasjon 1. Være oppmerksom på at dybdedimensjonen (750 mm) inkluderer kabelgjennomføringer. Tabell 2. Vekt på UPS-skap med pappemballasje C-modell 8-20 kW (Illustrasjon 1, bilde A) 15/20 kW ramme* (Illustrasjon 1, bilde B) 30/40 kW ramme* (Illustrasjon 1, bilde C) Fraktvekt 98 kg 293 kg 558 kg Vekt installert 86 kg 280 kg 532 kg 310 kg/m2 1107 kg/m2 1478 kg/m2 Gulvbelastning * Maksimalt antall interne batterier følger med alle modellene. UPS-skap bruker aktiv luftkjøling å regulere den innvendige komponenttemperaturen. Som standard er luftinnløpet foran på skapet og luftutløpet er bak, se illustrasjon 3. La det være en klaring foran og bak hvert skap for å oppnå en god luftsirkulasjon. Kontroller at kjøleluften som kommer inn i UPS-en ikke overstiger +40 °C. For ventilasjonskrav, se bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. 55 NO Tabell 3. Minimumsklaring for UPS-skap 15/20 kW ramme (Illustrasjon 1, bildene A og B) 30/40 kW ramme (Illustrasjon 1, bilde C) Fra toppen av skapet 500 mm 500 mm Fra fronten av skapet 500 mm 650 mm Fra baksiden av skapet 150 mm 250 mm 0 mm 0 mm Fra siden av skapet Den anbefalte omgivelsestemperaturen og luftfuktigheten for UPS-systemet er vist i illustrasjonene 4.1 og 4.2. Det anbefales en omgivelsestemperatur på mellom 20 °C og +25 °C for å oppnå en optimal levetid på VRLA-batteriene. Tabell 4.Minimum anbefalt flerlederkabel og sikringsstørrelser for likeretter og bypass-inngang og kabler for UPS-utgang (trefaseinngang, trefaseutgang) NO 93 PS UPS nominell effekt (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Likerettersikring [A] 20 20 32 40 63 80 Bypass-sikring [A] 20 20 32 40 63 80 PE-kabel [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] Maksimalt ledertverrsnitt 20 kW-ramme og 20 kW C-modell: massiv tråd 16 mm2, flettet ledning med endehylse: 10 mm 2 40kW-ramme: massiv tråd 70 mm2, flettet ledning med endehylse: 50 mm2 Tabell 5.Minimum anbefalt flerlederkabel og sikringsstørrelser for likeretter og bypass-inngang og kabler for UPS-utgang (trefaseinngang, enfaseutgang) 56 91PS UPS nominell effekt (kW) 8 10 15 20 30 Likeretterkabel [mm2] 2,5 4 10 10 16 Likerettersikring [A] 20 20 32 40 63 Bypass, utgangskabel [mm2] 10 16 25 35 70 Bypass-sikring [A] 50 63 80 100 160 PE-kabel [mm2] 10 16 16 16 35 91PS UPS nominell effekt (kW) 8 10 15 20 30 Maksimalt tverrsnitt leder, 15 kW-ramme og 15 kW Cmodell Likeretter: massiv ledning 16 mm2, flettet ledning med endehylse: 10 mm2 Likeretter/utgang: massiv ledning 70 mm 2, flettet ledning med endehylse: 50 mm 2 Maksimalt tverrsnitt leder, 30 kW-ramme Likeretter: massiv ledning 70 mm2, flettet ledning med endehylse: 50 mm2 Likeretter/utgang: massiv ledning 95 mm 2, flettet ledning med endehylse: 95 mm 2 FORSIKTIG Påse at prospektiv kortslutningsstrøm på UPS-inngangsterminalene er lik eller mindre enn betinget kortslutningsstrøm som er oppgitt på klassifiseringsskiltet på UPS-en. Tabell 6. Minimum anbefalte kabeldimensjoner og sikringsstørrelser for ekstern batteribank UPS nominell effekt (kW) 8 10 15 20 30 40 Pos. og neg. linje [mm2] 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Batterisikring [A] PE-kabel [mm2] Maksimalt ledertverrsnitt 15/20 kW-ramme, C-modell og 30/40 kW-ramme med separat batteri: massiv tråd: 25 mm2, flettet ledning med endehylse: 16 mm2 30/40 kW-ramme med fellesbatteri: massiv tråd: 90 mm2, flettet ledning med endehylse: 70 mm2 For informasjon om nominelle og maksimale strømmer for nominell effekt og spenning, se bruker- og installasjonsveiledning til Eaton 91PS/93PS UPS 8-40 kW. For alternativet med separat eksternt batteri, finnes det egne terminaler for begge batteribankene (kabinett), se seksjon 2.3.1. MERK: Det er ikke eksternt overspenningsvern med dette produktet, men kreves ihht. forskrifter. Se tabellene 4 og 5 for krav til kabling. Hvis det er behov for en låsbar skillebryter på utgangen, må brukeren selv sørge for dette. Tabell 7. Tiltrekkingsmoment for strømterminalene UPS-ramme Punkt Tiltrekningsmoment Nm 93PS 20 kW X1, X2, X3: L1, L2, L3, N 1.6 X4: batteri +/PE (jord) 93PS 40 kW 3 10 Nm for 16-35 mm2 kabel 6 Nm for 4-10 mm2 kabel 4 Nm for 2,5 mm2 kabel X1, X2, X3: L1, L2, L3, N 6 X4: batteri +/- 6 57 NO UPS-ramme 91PS 15 kW 91PS 30 kW NO Punkt Tiltrekningsmoment Nm PE (jord) 10 Nm for 16-35 mm2 kabel 6 Nm for 4-10 mm2 kabel 4 Nm for 2,5 mm2 kabel X1 1.6 X2, X3 7 X4 3 PE (jord) 10 Nm for 16-35 mm2 kabel 6 Nm for 4-10 mm2 kabel 4 Nm for 2,5 mm2 kabel X1 6 X2, X3 17 X4 6 PE (jord) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Handling All emballasje og beskyttelse er fjernet fra hvert av skapene. Hvert skap i UPS-systemet er plassert på installasjonssted. Det er installert jordingssett mellom eventuelle skap som er boltet sammen. Alle kabelkanaler og kabler er rutet til UPS-en og eventuelle ekstraskap. Alle strømkabler er av riktig dimensjon og terminert. Nøytralledere er koblet og jordet i henhold til kravene. Jordingsledning er korrekt koblet. Batterikablene er terminert og koblet til batterikontaktene. Signalledninger for batterishuntutløser og hjelpekontakt er koblet mellom UPS og batteribryter. Nettverkskabling er lagt opp. Alle nettverkskabler er tilkoblet. Ventilasjonsanlegg er installert og fungerer som det skal. Området rundt det installerte UPS-systemet er rent og støvfritt (det anbefales at UPS-en installeres på et plant gulv egnet for datautstyr og elektronisk utstyr). Det er tilstrekkelig med arbeidsområde rundt UPS-en og andre skap. Det er tilstrekkelig med belysning rundt alt UPS-utstyret. Det finnes et 230 VAC serviceuttak innen 7,5 meter fra UPS-utstyret. REPO-enheten (Remote Emergency Power-off) er montert på installasjonsposisjon og kablingen er terminert innvendig i UPS-skapet. Hvis EPO brukes i NC-konfigurasjon, kobles det en lask på EPO mellom pinn 1 og 2. (VALGFRITT) Alarmreléer og signalutganger er korrekt kablet. (VALGFRITT) En ekstern batterifrakoblingskontroll er montert på installasjonsposisjon og kablingen er terminert innvendig i UPS- og batteriskapet. (VALGFRITT) Tilbehøret er montert på installasjonsposisjon og kablingen er terminert innvendig i UPS-skapet. Oppstart og driftskontroller må utføres av en autorisert servicetekniker fra Eaton eller av 58 Ja/Nei Handling Ja/Nei kvalifisert servicetekniker som er autorisert av Eaton. Utpakking og løfting av UPS-enheten er vist i illustrasjonene 9.1 – 9.8. Før du begynner å pakke ut og løfte på plass UPS-enheten, sjekk TipNTell- og DropNTellindikatoren på emballasjen. Hvis utstyret har blitt korrekt transportert i stående stilling, skal indikatorene være intakt. Hvis TipNTell-indikatorpilen er fullstendig blå eller pilhodet(ene) av DropNTell-indikatoren er sort, kan du kontakte de aktuelle parter for å rapportere upassende transport. For transportformål er UPS-skapet boltet fast på en trepalle. Før skapet løftes fra pallen, må det brukes en gaffeltruck eller pallejekk for å flytte skapet til installasjonsområdet. ADVARSEL UPS-skapet er tungt. Hvis anvisningene for utpakking ikke overholdes nøye, kan skapet velte og forårsake alvorlig skade. Ikke vipp UPS-skapet mer enn 10 grader fra vertikal stilling, ellers kan det velte. NO MERK: Etter at fraktbrakettene er fjernet, flytt enheten umiddelbart av pallen. Etter at fraktbrakettene er fjernet og føttene er skrudd inn, må det ikke brukes gaffeltruck for å flytte enheten mens den står fortsatt på pallen. Vær oppmerksom på at UPS-skapet er tungt, og at det er hjul på undersiden. Hvis skapet skal flyttes til et nytt sted ved hjelp av en palle, må føttene på skapet senkes slik at skapet ikke lenger hviler på hjulene og fest fraktbrakettene til kabinettet og pallen. Operatøren må sørge for kabling for å koble UPS-en til det lokale strømnettet. Installasjon av UPS-en må gjøres av en autorisert elektriker lokalt. Inspeksjon etter installasjon, idriftsettelse av UPS-systemet og installasjon av ekstra batteriskap, må utføres av en autorisert servicetekniker fra Eaton eller av kvalifisert servicetekniker som er autorisert av Eaton. Installasjonen av UPS-enheten er vist i illustrasjonene 10.1-10.5. UPS strømkabelterminalene er vist i illustrasjonene 6.1 (91PS 15 kW ramme), 6.2 (93PS 20 kW ramme), 7.1 (91PS 30 kW ramme med et felles batteri), 7.2 (91PS 30 kW ramme med et separat batterialternativ), 8.1 (93PS 40 kW ramme med et felles batteri) og 8.2 (93PS 40 kW ramme med et separat batterialternativ). X1 X2 X3 X4/+ UPM2 Likeretterinngang Bypass-inngang UPS-utgang Eksternt batteri + (separat batteri) X4/TB20 TB21 PE Eksternt batteri Utløsn. eksternt batteri Utløsn. eksternt batteri Beskyttende jording 59 UPS-kommunikasjonsterminalene er vist i illustrasjonene 5.1 og 5.2. Terminalene er som følger: 1. 2. 3. 4. 5. 6. TB11, ikke i bruk TB10, ikke i bruk TB9, ikke i bruk TB8, ekstern CANterminering TB7, ekstern CAN TB6, pull-chain-buss 7. USB1, USB-vert (tilkobling til tilbehør) 8. USB2, USB-enhet (tilkobling til datamaskin) 9. MiniSlot 1 10. TB1, signalinngang 1-5 11. 12. 13. 14. 15. 16. TB2, ikke i bruk TB3, ikke i bruk Seriell COM-port RS-232 MiniSlot 2 TB4, EPO TB5, reléutgang Hvis kunden har et eget batterisystem som skal installeres, må batterisystemet installeres i henhold til instruksjonene fra produsenten av batterisystemet, samt alle gjeldende nasjonale lover og forskrifter. For batteriets spesifikasjoner, se bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. NO 91PS/93PS 8-40 kW UPS-enhetene er alltid utstyrt med en intern batteribryter, som kun påvirker UPS-ens interne batterier (med unntak av C-modellen, hvor den interne batteribryteren kan brukes for eksterne batterier). En ekstern batteribrytere er en avgjørende del av et eksternt batteriskap eller rack, og må monteres sådan. Med en ekstern batteribryter er det viktig med signalkabler. Både interne og eksterne batteribrytere kan bli utløst (slått av) ved at shuntutløserspolen strømsettes. Shuntutløserspolene på eksterne batteribrytere aktiveres (kontrollert) gjennom kontaktene TB20 og TB21 (TB21 kun tilgjengelig på 8-40 kW UPS med separat batterikonfigurasjon). Standardspenning shuntutløserspolen er 24 VDC. Batteriutløseren er vist i illustrasjon 11. Delene er som følger: A 1 2 Ekstern batteribryter Pinn 1, shuntutløserspole + Pinn 2, shuntutløserspole - 3 4 Pinn 3, hjelpekontakt Pinn 4, hjelpekontakt retur For instruksjoner om hvordan et eksternt batteriskap og strømtilkobling skal gjøres, se bruker- og installasjonsveiledningen for Eaton 91PS/93PS 8-40 kW og bruksanvisningen som følger med det eksterne batteriskapet. Det eksterne batteriskapet / kundens eget batterisystem må jordes til PE-terminal 17. EPO kobles til EPO-tilkoblingen på UPS-ens øverste frontpanel. Tilkoblingene av EPObryteren er vist i illustrasjon 12. For informasjon om installasjon av grensesnittforbindelser, se bruker- og installasjonsveiledningen til Eaton 91PS/93PS UPS 8-40 kW. 60 Det er som standard én universal relékontakt på UPS-en. Det er også en alarmkontakt. Utgangsreléets konfigurasjoner er vist i illustrasjon 13. Det kan brukes en Normalt lukket eller Normalt åpen kontakt. Dersom kontaktstatus endres fra status som er angitt som normal, vil det sendes ut et signal. Denne kontakten kan kobles til utstyr på anlegget (for eksempel lampe eller horn) for å varsle deg når en alarm er aktiv på UPS-en. MERK: Kontakter skal ikke brukes over maks. 30 VAC (RMS) og 30 VDC ved 5 A. For informasjon om kobling av parallelle 91PS/93PS UPS-systemer, se bruker- og installasjonsveiledningen for Eaton 91PS/93PS UPS 8-40 kW. NO 61 1 FARE Vigtige sikkerhedsoplysninger! Gem disse anvisninger! Dette dokument indeholder vigtige sikkerhedsinstruktioner og en kort introduktion til, hvordan UPS-anlægget skal kontrolleres ved leveringen, og hvordan det skal installeres. Denne Quick Guide er kun beregnet til brug som en tjekliste i forbindelse med installation på stedet. Dette dokument er udarbejdet til erfarent, fagkyndigt personale, som planlægger og udfører installationen af UPS-anlægget. FARE Inden du udfører arbejde på UPS-anlægget, skal du læse alle installationsinstruktionerne i bruger- og installationsvejledningen til Eaton 91PS/93PS 8-40 kW UPS. De samlede instruktioner kan downloades på www.eaton.eu/91psand93ps. Indgreb inde i UPS-anlægget skal udføres af en autoriseret tekniker fra Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. Der findes ingen indvendige dele i UPS-anlægget, som skal vedligeholdes af brugeren. DA UPS-anlægget fungerer med netstrøm, batteri eller bypasseffekt. Det indeholder komponenter, som leder høj strøm og spænding. Et korrekt installeret kabinet er jordforbundet og IP20-klassificeret mod elektrisk stød og fremmede genstande. UPSanlægget er et sofistikeret strømsystem, og det må kun installeres og serviceres af kvalificeret personale. FARE Dette UPS-anlæg indeholder livsfarlig spænding. Batterierne udgør en fare for elektrisk stød eller forbrænding fra høj kortslutningsstrøm. Overhold forholdsreglerne. Batterier kan indeholde HØJE SPÆNDINGER og ÆTSENDE, GIFTIGE og BRANDFARLIGE stoffer. På grund af batteristrengen kan udgangsstikkene stadig være under høj spænding, efter at AC-strømforsyningen til UPS-anlægget er afbrudt. Læs instruktionerne i afsnittet nedlukning i bruger- og installationsvejledningen. ADVARSEL UPS-anlægget strømforsynes af sin egen energikilde (batterier). Udgangsklemmerne kan være strømførende, efter at UPS-anlægget er afbrudt fra vekselstrømkilden. For at reducere risikoen for brand eller elektrisk stød, skal UPS-anlægget installeres i indendørs omgivelser, hvor temperatur og fugtighed er kontrolleret. Desuden må omgivelserne ikke indeholde ledende kontaminanter. Stil ikke UPS 91PS/93PS C-modellens kabinet oven på et andet/andre tilsvarende kabinet(er). Stil ikke nogen genstande oven på 91PS/93PS UPS-kabinettet. Hvis UPS 91PS/93PS C-modellens kabinet er installeret på en hylde, skal der anvendes den nødvendige understøtning for at sikre, at UPS-enheden ikke kan vælte eller falde ned. 62 ADVARSEL Omgivelsestemperaturen må ikke overskride 40 °C. Brug aldrig UPS-anlægget i nærheden af vand eller høj fugtighed (maks. 95 %). Systemet er ikke beregnet til udendørs opstilling. Inden du påbegynder installation eller service, skal du kontrollere, at alle veksel- og jævnstrømskilder er afbrudte. Effekt kan tilføres fra flere kilder. Sørg også for tilslutning af jordforbindelse/PE-kontinuitet. Udgangsklemmerne kan være strømførte i et parallelt system, også efter at UPSanlægget er slukket. Fare for elektricitet. Forsøg ikke at ændre på batteriets kabler eller stik. Der er fare for at komme til skade. VIGTIGT: Sørg for at afbryde alle batteristrenge før installationen. FORSIGTIG Installation og servicering af batterierne må kun udføres af servicepersonale, som har kendskab til batterierne og de nødvendige forholdsregler. Batterierne er strømførende og både installation og serviceopgaver kræver brug af spændingsmålere. Hold uautoriseret personale på afstand af batterierne. Før du installerer eller udskifter batterierne, skal du tage alle advarsler, forholdsregler og bemærkninger angående korrekt håndtering i betragtning. Afbryd ikke batterierne, når UPS-anlægget er i batteritilstand. Sørg for, at dine reservebatterier har samme nummer og type som batteriet, der oprindeligt blev installeret i UPS-anlægget. Se flere detaljer om UPS-anlægget. Inden du tilslutter eller afbryder batteriklemmerne, skal opladekilden afbrydes ved at åbne den relevante batterikredsafbryder. Kontroller, om batterierne utilsigtet er jordforbundet. Hvis det er tilfældet, skal kilden til jorden fjernes. Der er risiko for elektrisk stød ved kontakt med en hvilken som helst del af et jordforbundet batteri. Kassér batterierne som anvist i de lokalt gældende bestemmelser for aflevering af affald. Kast ikke batterierne i åben ild. Batterierne kan eksplodere, når de udsættes for åben ild. For at reducere risikoen for brand må tilslutningen kun udføres til en kreds, der er forsynet med en indgangskredsafbryder med maksimale mærkestrømme i overensstemmelse med nationale og lokale installationsregler. For at sikre en passende afkølende luftstrøm og beskytte personalet mod farlig spænding inde i enheden skal UPS-anlæggets dør holdes lukket, og frontpanelerne skal være monteret. Installer og brug ikke UPS-anlægget i nærheden af gas eller elektriske varmekilder. Sørg for, at driftsomgivelserne opfylder parametrene, som er opført i dette dokument. Hold UPS-anlæggets omgivelser ryddelige, rene og fri for overdreven fugt. Overhold alle skilte med FARE-, FORSIGTIGHEDS- OG ADVARSELSSYMBOLER, som forefindes inde i og uden på udstyret. 63 DA 2 Eaton® 91PS/93PS nødstrømforsyning (UPS) er et ægte solid state enfaset (91PS) onlinesystem i konstant funktion, uden transformer og med dobbeltkonvertering eller et trefaset system (93PS). Den leverer reguleret og uafbrudt vekselstrøm til kritisk udstyr og beskytter det mod svigt i strømforsyningen. Værdierne for udgangseffekten af Eaton 91PS/93PS er baseret på uafbrudte effektmoduler (UPM'er) med en nominel værdi på 15 kW eller 20 kW. 91PS/93PS kan også fås som en C-model, der består af den elektriske del i 91PS/93PS UPS 15/20 kW ramme uden batterirummet. Tabel 1. Værdier for UPS-kabinet DA UPS-ramme Billede (Figur 1) Antal UPM’er Værdier 91PS 15 kW A og B 1 8, 10, 15 kW 91PS 30 kW C 1 eller 2 8, 10, 15, 20, 30 kW 93PS 20 kW A og B 1 8, 10, 15 eller 20 kW 93PS 40 kW C 1 eller 2 8, 10, 15, 20, 30 or 40 kW Hovedkomponenterne i 91PS/93PS UPS 8-40 kW er vist i figur 2. Hovedkomponenterne er følgende: 1. 2. 3. 4. . Kontrolpanel Dørlås Effektmodul (UPM) Internt batteri (ikke i C-moduler) 5. 6. 7. 8. Kommunikationsområde Indgangsswitch Batteriafbryder Bypassswitch til brug under vedligeholdelse (ekstraudstyr) FARE Dette UPS-anlæg indeholder livsfarlig spænding. Indgreb inde i UPS-anlægget skal udføres af en autoriseret tekniker fra Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. Der findes ingen indvendige dele i UPS-anlægget, som skal vedligeholdes af brugeren. Alle sikkerhedsinstruktioner kan findes i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. UPS-enheden skal installeres i overensstemmelse med anvisningerne i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. Brug den følgende standardprocedure til installation af UPS-anlægget: 1. 64 Udarbejd en installationsplan for UPS-anlægget. 2. 3. 4. 5. 6. Forbered UPS-anlæggets installationssted. Efterse og pak UPS-kabinettet ud. Installer UPS-kabinettet og ledningsnettet. Udfyld tjeklisten for installationen. Få autoriseret servicepersonale til at udføre de indledende kontroller af driften og første ibrugtagning. BEMÆRK: Idriftsættelse og kontrol af driften skal udføres af en autoriseret tekniker fra Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. I modsat fald bortfalder garantien. Inden du installerer UPS-anlægget, skal du læse og sætte dig grundigt ind i, hvordan disse instruktioner gælder for det system, som du skal installere. Brug procedurerne og figurerne til at oprettet et logisk diagram for systemets installation. Det er nødvendigt, at installationsstedet opfylder de specifikationer for omgivelserne, som er anført i bruger- og installationsvejledningen for Eaton 91PS/93PS UPS 8-40 kW. Installationsmiljøet skal opfylde kravene til UPS-anlæggets vægt og størrelse som er anført i tabel 2 og 3. UPS-kabinettets mål er vist i figur 1. Bemærk, at målet for dybden (750 mm) er inklusive kabelforskruninger. Tabel 2. UPS-kabinettets vægt med papemballage C-model 8-20 kW (Figur 1, billede A) 15/20 kW-ramme* (Figur 1, billede B) Forsendelsesvægt 98 kg 293 kg 558 kg Installeret vægt 86 kg 280 kg 532 kg Gulvbelastning 310 kg/m2 1107 kg/m2 1478 kg/m2 30/40 kW-ramme* (Figur 1, billede C) Det maksimale antal interne batterier er inkluderet for alle modeller. UPS-kabinetterne anvender konstant luftafkøling til regulering af komponenternes indvendige temperatur. Som standard er luftindtagene placeret på kabinettets forside, og luftudledningerne på bagsiden, jf. figur 3. Sørg for, at der er tilstrækkeligt frirum foran og bagved hvert kabinet til at luften kan cirkulere korrekt. Sørg for, at temperaturen for afkølingsluften, som suges ind i UPS-enheden, ikke overstiger +40 °C. Se bruger- og installationsvejledningen for Eaton 91PS/93PS UPS 8-40 kW for oplysninger om krav til ventilationen. 65 DA Tabel 3. Mindste frirum for UPS-kabinet 15/20 kW-ramme (Figur 1, billede A og B) 30/40 kW-ramme (Figur 1, billede C) Fra kabinettets top 500 mm 500 mm Fra kabinettets forside 500 mm 650 mm Fra kabinettets bagside 150 mm 250 mm 0 mm 0 mm Fra kabinettets side Den anbefalede temperatur for USP-systemets driftsomgivelser og fugtighed er vist i figur 4.1 og 4.2. En omgivelsestemperatur på mellem +20 °C og +25 °C anbefales for at sikre VRLA-batteriernes lange levetid. Tabel 4. Anbefalede minima for flerlederkabler og sikringsstørrelser for ensretter og bypassindgang og UPS-udgangskabler (modeller med 3-faset indgang, 3-faset udgang) 93PS UPS-effekt (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Ensrettersikring [A] 20 20 32 40 63 80 Bypasssikring [A] 20 20 32 40 63 80 PE-kabel [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Ledning [mm2] DA Maks. tværsnit for leder 20 kW ramme og 20 kW C-model: massiv ledning 16 mm2, snoet tråd med ferule: 10 mm2 40 kW ramme: massiv ledning 70 mm2, snoet tråd med ferrule: 50 mm2 Tabel 5. Anbefalede minima for flerlederkabler og sikringsstørrelser for ensretter og bypassindgang og UPS-udgangskabler (3-faset indgang, 1-faset udgang) 91PS UPS-effekt (kW) 8 10 15 20 30 Ensretterindgang, kabel [mm2] 2,5 4 10 10 16 Ensrettersikring [A] 20 20 32 40 63 Bypass, udgangskabel [mm2] 10 16 25 35 70 Bypasssikring [A] 50 63 80 100 160 PE-kabel [mm2] 10 16 16 16 35 Maks. tværsnit for leder, 15 kW ramme og 15 kW C-model 66 Ensretter: 40 kW-ramme: massiv ledning 16 mm 2, snoet tråd med ferrule: 10 mm2 Bypass/udgang: massiv ledning 70 mm 2, snoet tråd med ferrule: 50 mm2 91PS UPS-effekt (kW) 8 10 15 20 30 2 Maks. tværsnit for leder, 30 kW- Ensretter: 40 kW ramme: massiv ledning 70 mm , 2 snoet tråd med ferrule: 50 mm ramme Bypass/udgang: massiv ledning 95 mm 2, snoet tråd med ferrule: 95 mm2 FORSIGTIG Sørg for, at den prospektive kortslutningsstrøm, som opstår på UPS-anlæggets indgangsklemmer, er lig med eller mindre end den betingede kortslutningsstrøm, som er angivet på UPS-anlæggets effektskilt. Tabel 6. Anbefalede minimum for kabler og sikringsstørrelser for ekstern batteribank UPS-effekt (kW) Pos. og neg. linje [mm2] Batterisikring [A] PE-kabel [mm2] Maks. tværsnit for leder 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 15/20 kW-ramme, C-model og 30/40 kW-ramme med separat batteri: massiv ledning: 25 mm2, snoet tråd med ferule: 16 mm2 30/40 kW-ramme med fælles batteri: massiv ledning: 90 mm2, snoet tråd med ferule: 70 mm2 DA Oplysninger om mærkestrøm og maksimum strøm for nominel effekt og spænding kan findes i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. Til den eksterne, separate batterifunktion findes separate klemmer for begge batteribanker (kabinetter). Se afsnit 2.3.1. BEMÆRK: Ekstern overstrømsbeskyttelse følger ikke med dette produkt, men er påkrævet iht. standarderne. Se Tabel 4 og 5 for krav til kabelføring. Hvis en aflåselig udgangsafbryder er påkrævet, skal den anskaffes af brugeren. Tabel 7. Tilspændingsmomenter for klemmerne på UPS-anlæggets strømkabel UPS-ramme Funktion Tilspændingsmoment Nm 93PS 20 kW X1, X2, X3: L1, L2, L3, N 1.6 X4: batteri +/PE (jord) 93PS 40 kW 3 10 Nm for 16-35 mm2 ledning 6 Nm for 4-10 mm2 ledning 4 Nm for 2,5 mm2 ledning X1, X2, X3: L1, L2, L3, N 6 X4: batteri +/- 6 PE (jord) 10 Nm for 16-35 mm2 ledning 6 Nm for 4-10 mm2 ledning 4 Nm for 2,5 mm2 ledning X1 1.6 67 UPS-ramme Funktion Tilspændingsmoment Nm 91PS 15 kW X2, X3 7 X4 3 PE (jord) 10 Nm for 16-35 mm2 ledning 6 Nm for 4-10 mm2 ledning 4 Nm for 2,5 mm2 ledning X1 6 X2, X3 17 X4 6 PE (jord) 7 Nm (X1, X2, X3) 3.5 Nm (X4) 91PS 30 kW Handling Al emballage og fastgøringsmidler er blevet fjernet fra alle kabinetter. Hvert kabinet i UPS-anlægget er placeret på installationsstedet. Et jordtilslutningssæt og monteringssæt er installeret mellem kabinetter, som er sammenboltede. Alle rør og kabler er ført korrekt til UPS-anlægget og eventuelle andre kabinetter. DA Alle strømførende kabler er korrekt dimensionerede og korrekt afsluttede. Neutrale ledere er installeret og jordet i henhold til kravene. En jordleder er korrekt installeret. Batterikablerne er afsluttet og tilsluttet til batteristikkene. Batterishuntudløsning og AUX-kontaktsignalets kabler er tilsluttet fra UPS-anlægget til batteriafbryderen. LAN-stikmoduler er installerede. Alle LAN-forbindelser er afsluttede. Aircondition-udstyr er installeret og fungerer korrekt. Området omkring det installerede UPS-anlæg er rent og støvfrit (det anbefales at UPSanlægget installeres på et plant gulv, som er egnet til computer- og elektronisk udstyr). Der er tilstrækkelig arbejdsplads omkring UPS-anlægget og andre kabinetter. Der findes passende belysning omkring hele UPS-anlægget og tilhørende udstyr. En 230 VAC-stikudgang er placeret inden for en afstand på 7,5 meter fra UPS-udstyret. Fjernbetjent nødslukning (REPO) er monteret på dens installationssted og dens kabelføring er afsluttet inde i UPS-kabinettet. Hvis der anvendes EOP i NC-konfigurationen, er der installeret en jumper på EOP mellem benene 1 og 2. (EKSTRAUDSTYR) Alarmrelæer og signaludgange har korrekt kabelføring. (EKSTRAUDSTYR) En ekstern batteriafbryderstyring er monteret på dets installationssted, og dens kabelføring er afsluttet inde i UPS-anlægget og batterikabinettet. (EKSTRAUDSTYR) Tilbehør er monteret på dets installationssteder, og dets kabelføring er afsluttet inden i UPS-kabinettet. Idriftsættelse og kontrol af driften skal udføres af en autoriseret tekniker fra Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. 68 Ja/Nej Udpakning og aflæsning af UPS-enheden er vist i figur 9.1 - 9.8. Inden du pakker UPS-anlægget ud og aflæsser det, skal TipNTell/DropNTell-indikatorerne på pakkens overflade kontrolleres. Hvis udstyret er blevet transporteret korrekt i opret position, vil indikatorerne være intakte. Hvis TipNTell-indikatorpilen er blevet blå, eller pilehovederne på DropNTell-indikatoren er sorte, skal de relevante parter kontaktes med anmeldelse af ukorrekt transport. Under transporten er UPS-kabinettet boltet fast til en træpalle. Inden kabinettet tages ned af pallen, flyttes det til installationsstedet ved hjælp af en gaffeltruck eller andet løfteudstyr. ADVARSEL UPS-kabinettet er tungt. Hvis udpakningsinstruktionerne ikke overholdes nøje, kan kabinettet krænge over og forårsage alvorlige skader. Vip ikke UPS-kabinettet mere end 10 grader i vertikal retning, ellers kan det krænge over. BEMÆRK: Enheden skal tage ned fra pallen, så snart transportremmene er fjernet. Når transportremmene er fjernet og justeringsfødderne trukket op, må der ikke længere bruges gaffeltruck til at løfte enheden ned fra pallen. Bemærk, at UPS-kabinettet er tungt, og der er hjul under kabinettet. Hvis du flytter kabinettet fra dets oprindelige opstillingssted og flytter det til et nyt sted på en palle, skal justeringsfødderne sænkes indtil kabinettet ikke længere støtter på hjulene. Transportbeslagene skal fastgøres til kabinettet og pallen. Operatøren skal levere kabelføringen til tilslutning af UPS-anlægget til den lokale strømkilde. Installationen af UPS-anlægget skal udføres af en lokal, kvalificeret elektriker. Inspektion af installationen og den første ibrugtagning af UPS-anlægget samt installation af et ekstra batterikabinet skal udføres af autoriseret tekniker fra Eatons kundeservice eller af kvalificeret servicepersonale autoriseret af Eaton. Installation af UPS-anlægget er vist i figur 10.1-10.5. UPS-strømkablets klemmer er vist i figur 6.1 (91PS 15 kW-ramme), 6.2 (93PS 20 kWramme), 7.1 (91PS 30 kW-ramme med fælles batteri), 7.2 (91PS 30 kW-ramme med valgfrit separat batteri), 8.1 (93PS 40 kW-ramme med fælles batteri) og 8.2 (93PS 40 kWramme med valgfrit separat batteri). X1 X2 X3 X4/+ UPM2 Ensretterindgang Bypassindgang UPS-udgang Eksternt batteri + (separat batteri) X4/TB20 TB21 PE Eksternt batteri Ekstern batteriudløser Ekstern batteriudløser Jordingsbeskyttelse 69 DA UPS-enhedens kommunikatiosklemmer er vist i figur 5.1 og 5.2. Klemmernes tildeling er følgende: 1. 2. 3. 4. 5. 6. TB11, ikke anvendt TB10, ikke anvendt TB9, ikke anvendt TB8, ekstern CANafslutning TB8, ekstern CAN TB6, pull chain-bus 7. USB1, USB-vært (tilslutning til tilbehør) 8. USB2, USB-enhed (tilslutning til computer) 9. Minislot 1 10. TB1, signalindgang 1-5 11. 12. 13. 14. 15. 16. TB2, ikke anvendt TB3, ikke anvendt Seriel COM-port RS-232 Minislot 2 TB4, EPO TB5, relæudgang Hvis kundens eget batterisystem skal installeres, skal systemet installeres som anvist af batteriets og batterisystemets producent, og alle nationale regler og bestemmelser skal overholdes. Oplysninger om batterispecifikationer kan findes i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. 91PS/93PS 8-40 kW UPS-enhederne er altid udstyret med en intern batteriafbryder, som kun afbryder UPS-enhedens interne batterier (undtagen for C-modellen, hvor den interne batteriafbryder kan bruges til eksterne batterier). Den eksterne batteriafbryder er en central del af det eksterne batterikabinet eller stativ, og skal placeres inde i dette. Med ekstern batteriafbryder er signalkablingen vigtig. DA Både interne og eksterne batteriafbrydere kan udløses (afbrydes) ved at tilføre strøm til deres shuntudløserspole. Shuntudløserspolerne i de eksterne batteriafbrydere er strømførte (styrede) gennem stikkene TB20 og TB21 (TB21 er kun tilgængelig på 8-40 kW UPS med separat batterikonfiguration). Standardspændingen for shuntudløserspolen er 24 VDC. Batteriudløserens ledningsføring er vist i figur 11. Komponenterne er følgende: A 1 2 Ekstern batteriafbryder Ben 1, Shuntudløsning spole + Ben 2,shuntudløsningsspole + 3 4 Ben 3, AUX-kontakt Ben 4, AUX-kontakt retur Se bruger- og installationsvejledningen til Eaton 91PS/93PS 8-40 kW UPS og instruktionsvejledningen, som følger med det eksterne batterikabinet, for instruktioner om installation af det eksterne batterikabinet og batteriets strømkabler. Det eksterne batterikabinet/det kundeleverede batterisystem skal jordforbindes til PE-klemme 17. EPO er tilsluttet EPO-konnektoren på UPS-anlæggets øverste frontpanel. EPO-kontaktens tilslutninger er vist i figur 12. Oplysninger om installation af grænsefladetilslutningerne kan findes i bruger- og installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. 70 En allround relækontakt leveres som standard på UPS-anlægget. Der findes også en alarmkontakt. Udgangsrelæernes konfigurationer er vist i figur 13. Du kan bruge en normalt lukket eller normalt åben kontakt. Hvis kontaktens tilstand skifter fra den tilstand, du angiver som normal, udstedes et signal. Du kan tilslutte denne kontakt til udstyr på din enhed (f.eks. en lampe eller en alarmklokke), som giver dig besked, når en alarm er aktiv på UPS-anlægget. BEMÆRK: Brug ikke kontakter som overskrider 30 VAC (RMS) og 30 VDC ved 5 A maksimum. Oplysninger om parallel ledningsføring af 91PS/93PS UPS-systemer kan findes i brugerog installationsvejledningen til Eaton 91PS/93PS UPS 8-40 kW. DA 71 1 Безопасность ОПАСНОСТЬ Важные сведения по технике безопасности! Храните эти инструкции в доступном месте! В данном документе приводятся важные правила техники безопасности и краткие инструкции по проверке ИБП после поставки, установке и его эксплуатации. Это краткое руководство может использоваться только в качестве контрольного списка при установке устройства на объекте. В целевую аудиторию читателей данного руководства входят опытные специалисты, планирующие и выполняющие установку ИБП. ОПАСНОСТЬ Прежде чем приступить к эксплуатации ИБП, ознакомьтесь с инструкциями, приведенными в Руководстве по установке и эксплуатации ИБП Eaton 91PS/93PS UPS 8–40 кВт. Полную версию инструкций можно загрузить с сайта www.eaton.com/91psand93ps. К проведению работ внутри ИБП допускается только сервисный инженер службы клиентской поддержки Eaton или квалифицированные специалисты, уполномоченные компанией Eaton. В этом ИБП нет деталей, обслуживаемых пользователем. ИБП работает от сети питания, аккумулятора или линии байпаса. В нем содержатся компоненты, в которых присутствуют высокие токи и напряжения. Правильно установленный корпус должен быть заземлен и иметь степень защиты IP20 от поражения электрическим током и попадания посторонних предметов. Помните, что ИБП является сложной силовой системой и к его эксплуатации и обслуживанию допускается только квалифицированный персонал. RU ОПАСНОСТЬ В данном ИБП присутствует опасное для жизни напряжение. Аккумуляторы могут стать причиной поражения электрическим током или ожогов вследствие КЗ, вызванного большими токами. Соблюдайте меры предосторожности. Аккумуляторы могут быть под ВЫСОКИМ НАПРЯЖЕНИЕМ, а также содержать КОРРОЗИЙНЫЕ, ТОКСИЧНЫЕ и ВЗРЫВООПАСНЫЕ вещества. Ввиду наличия аккумуляторного блока помните, что на выходной розетке также может присутствовать высокое напряжение даже при условии, что к ИБП не подключен источник питания переменного тока. Инструкции по выключению приводятся в Руководстве по установке и эксплуатации. ПРЕДУПРЕЖДЕНИЕ Для питания ИБП используются собственные источники энергии (аккумуляторы). На выходных клеммах может присутствовать напряжение даже после отключения ИБП от источника питания переменного тока. Для уменьшения опасности возгорания или поражения электрическим током следует устанавливать данный ИБП в помещении с контролируемой температурой и влажностью, и отсутствием посторонних примесей, способных проводить электрический ток. Не устанавливайте шкаф ИБП модели 91PS/93PS C на другой схожий шкаф или шкафы. Не ставьте никаких посторонних предметов на шкаф ИБП 91PS/93PS. При установке шкафа ИБП модели 91PS/93PS C на полку используйте соответствующие опоры, предотвращающие опрокидывание или падение ИБП. 72 ПРЕДУПРЕЖДЕНИЕ Температура воздуха не должна превышать 40°C (104°F). Не устанавливайте ИБП вблизи от воды или в местах с повышенной влажностью (максимум 95%). Система не предназначена для эксплуатации вне помещений. Перед началом операций установки или обслуживания убедитесь, что отключены источники питания с переменным и постоянным током. Электропитание может поступать из нескольких источников. Также обеспечьте неразрывность рабочего/защитного заземления. На выходных клеммах параллельной системы может присутствовать напряжение даже после выключения ИБП. Опасность поражения электрическим током. Во избежание получения травм, запрещается вносить изменения в схему подключения или соединения аккумуляторов. ВАЖНО: Перед установкой убедитесь, что отключены все аккумуляторные блоки. ВНИМАНИЕ К установке и обслуживанию устройства допускаются только квалифицированный технический персонал, обладающий необходимыми знаниями по аккумуляторам и технике безопасности. Установка и обслуживание АКБ производится под напряжением и требует использования электроизоляционного инструмента. Необходимо ограничить доступ посторонних лиц к аккумуляторам. Перед установкой или заменой аккумуляторов необходимо прочитать все предупреждения, предостережения и примечания по технике безопасности. Запрещается отключать аккумуляторы во время работы ИБП от аккумулятора. Количество и тип заменяемых аккумуляторов должны совпадать с оригинальными аккумуляторами, установленными в ИБП. См. более подробную информацию в руководстве по эксплуатации ИБП. Перед подключением или отключением клемм АКБ отключите его от источника питания, разомкнув соответствующий прерыватель цепи. Проверьте аккумулятор на предмет непреднамеренного заземления. При обнаружении такого заземления устраните его. Контакт с любой частью заземленного аккумулятора может привести к поражению электрическим током. Утилизация аккумуляторов выполняется в соответствии с требованиями местного законодательства в отношении утилизации. Запрещается сжигать аккумуляторы. Под воздействием пламени возможен взрыв аккумуляторов. Для уменьшения опасности возгорания подключайтесь только к цепи, оснащенной входным выключателем с максимальным номинальным входным током в соответствии с национальными и местными правилами установки. Для обеспечения надлежащего охлаждения системы и защиты персонала от опасного напряжения, присутствующего в устройстве, следует держать дверцу ИБП закрытой и установить передние панели. Запрещается установка или эксплуатация системы ИБП вблизи газовых или электрических источников тепла. Условия эксплуатации должны соответствовать требованиям, приведенным в настоящем документе. В помещении с ИБП следует поддерживать чистоту, избегать высокой влажности и нагромождения посторонних предметов. Соблюдайте требования, указанные на табличках с надписями ОПАСНОСТЬ, ВНИМАНИЕ и ПРЕДУПРЕЖДЕНИЕ, расположенных на внешней и внутренней поверхностях оборудования. 73 RU 2 Установка ИБП Eaton 91PS/93PS 2.1 Введение в ИБП Eaton 91PS/93PS Источник бесперебойного питания (ИБП) Eaton® 91PS/93PS представляет собой оперативную систему: непрерывного действия, бестрансформаторная, двухдиапазонная, полупроводниковая, однофазная (91PS) или трехфазная (93PS). ИБП служит для непрерывной подачи гармонизированного переменного тока к критической нагрузке и защищает ее от отказов системы электроснабжения. Значение номинальной выходной мощности Eaton 91PS/93PS рассчитано с учетом модулей бесперебойного питания (UPM) с номиналом 15 или 20 кВт. Устройство 91PS/93PS также выпускается в модификации «C», которая состоит из электрической части рамы ИБП 91PS/93PS на 15/20 кВт без отсека для аккумуляторов. Таблица 1. Номинальные ВАХ шкафа ИБП Рама ИБП Рис. (Иллюстрация 1) Количество ИБП Номинальные ВАХ 91PS 15 кВт AиB 1 8, 10, 15 кВт 91PS 30 кВт C 1 или 2 8, 10, 15, 20, 30 кВт 93PS 20 кВт AиB 1 8, 10, 15 или 20 кВт 93PS 40 кВт C 1 или 2 8, 10, 15, 20, 30 или 40 кВт Основные компоненты ИБП 91PS/93PS UPS 8-40 кВт показаны на рисунке 2. Устройство состоит из следующих основных компонентов: RU 1. 2. 3. 4. Панель управления Дверной замок Модуль питания (UPM) Внутренний аккумулятор (не в моделях «C») . 5. 6. 7. 8. Зона средств связи Входной переключатель Выключатель аккумулятора Переключатель сервисного байпаса (дополнительно) ОПАСНОСТЬ В данном ИБП присутствует опасное для жизни напряжение. К проведению работ внутри ИБП допускается только сервисный инженер службы клиентской поддержки Eaton или квалифицированные специалисты, уполномоченные компанией Eaton. В этом ИБП нет деталей, обслуживаемых пользователем. Полный текст инструкций по технике безопасности приводится в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 2.1 Окружающая среда Установка ИБП выполняется в соответствии с рекомендациями, приведенными в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 2.2 План распаковки и установки ИБП Для установки ИБП выполните следующую последовательность шагов: 74 1. 2. 3. 4. 5. 6. Составьте план установки системы ИБП. Подготовьте объект к установке системы ИБП. Осмотрите и распакуйте шкаф ИБП. Выгрузите и установите шкаф ИБП и подключите проводку системы. Заполните контрольный список по установке. Вызовите квалифицированных специалистов для проведения предварительной регламентной проверки и ввода в эксплуатацию. ПРИМЕЧАНИЕ: Запуск и регламентные проверки должны выполняться квалифицированным специалистом сервисного центра Eaton или квалифицированными специалистами, уполномоченными компанией Eaton, в противном случае будут аннулированы гарантийные обязательства. 2.2.1 Создание плана установки Перед установкой системы ИБП внимательно прочитайте приведенные инструкции по установке соответствующей системы. Создайте логичный план установки системы согласно инструкциям и рисункам. 2.2.2 Подготовка объекта Для обеспечения максимальной производительности системы ИБП окружающая среда в месте установки устройства должна соответствовать параметрам, приведенным в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 2.2.2.1 Рекомендации по условиям окружающей среды и установке Условия установки должны соответствовать требованиям веса и размеров ИБП, указанным в Таблицах 2 и 3. Размеры шкафа ИБП показаны на рисунке 1. Помните, что глубина установки (750 мм) учитывает размер кабельных уплотнений. Таблица 2. Массы шкафов ИБП с картонной упаковкой Модель C, 8–20 кВт (Иллюстрация 1, рис. А) Рама на 15/20 кВт* (Иллюстрация 1, рис. В) Рама на 30/40 кВт* (Иллюстрация 1, рис С) Транспортный вес 98 кг 293 кг 558 кг Вес установленного оборудования 86 кг Нагрузка на пол 310 кг/м2 280 кг 1 107 кг/м2 532 кг 1 478 кг/м2 * В комплект всех моделей входит максимальное количество встроенных аккумуляторов. Для регулировки температуры внутренних компонентов в шкафах ИБП используется принудительное воздушное охлаждение. По умолчанию, воздухоприемники расположены в передней части шкафа, а воздуховыпускные отверстия — в задней, см. рисунок 3. Для обеспечения правильной циркуляции воздуха впереди и сзади каждого шкафа необходимо оставлять достаточно свободного пространства. Убедитесь, что температура входящего в ИБП охлаждающего воздуха не превышает +40 °C. Требования к вентиляции приводятся в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 75 RU Таблица 3. Минимальное свободное пространство вокруг шкафа ИБП Рама на 15/20 кВт (Иллюстрация 1, рис. А и В) Рама на 30/40 кВт (Иллюстрация 1, рис. С) Свободное пространство сверху 500 мм 500 мм Свободное пространство спереди 500 мм 650 мм Свободное пространство сзади 150 мм 250 мм Свободное пространство сбоку 0 мм 0 мм На рисунках 4.1 и 4.2 показана рекомендуемая рабочая температура окружающего воздуха и влажность для работы системы ИБП. Для обеспечения длительного срока службы аккумуляторов VRLA рекомендуется поддерживать температуру окружающей среды в диапазоне от +20 °C до +25 °C. 2.2.2.2 Подготовка силовой проводки системы ИБП Таблица 4. Минимальные рекомендуемые сечения многожильных кабелей и размеры предохранителей для выпрямительных и байпасных входов и выходных кабелей ИБП (3-фазный вход, 3-фазный выход) Номинальные ВАХ (кВт) ИБП 93PS RU 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Предохранитель выпрямителя [A] 20 20 32 40 63 80 Предохранитель байпаса [A] 20 20 32 40 63 80 Кабель заземления [мм2] 1*6 1*6 1*10 1*10 1*16 1*16 Кабель [мм2] Максимальное поперечное сечение проводника Рама 20 кВт и 20 кВт модели «C»: одножильный провод 16 мм2, многожильный провод с изоляционной трубкой: 10 мм2 Рама 40 кВт: одножильный провод 70 мм2, многожильный провод с изоляционной трубкой: 50 мм2 Таблица 5. Минимальные рекомендуемые сечения многожильных кабелей и размеры предохранителей для выпрямительных и байпасных входов и выходных кабелей ИБП (3-фазный вход, 1-фазный выход) 76 Номинальные ВАХ (кВт) ИБП 91PS 8 10 15 20 30 Кабель выпрямителя [мм2] 2,5 4 10 10 16 Предохранитель выпрямителя [A] 20 20 32 40 63 Номинальные ВАХ (кВт) ИБП 91PS 8 10 15 20 30 Байпас, внешний кабель [мм2] 10 16 25 35 70 Предохранитель байпаса [A] 50 63 80 100 160 Кабель заземления [мм2] 10 16 16 16 35 Максимальное поперечное сечение проводника, рама на 15 кВт и модель С на 15 кВт Выпрямитель: одножильный провод 16 мм2, многожильный провод с изоляционной трубкой: 10 мм2 Байпас/выход: одножильный провод 70 мм2, многожильный провод с изоляционной трубкой: 50 мм2 Максимальное поперечное сечение проводника, рама на 30 кВт Выпрямитель: одножильный провод 70 мм2, многожильный провод с изоляционной трубкой: 50 мм2 Байпас/выход: одножильный провод 95 мм2, многожильный провод с изоляционной трубкой: 95 мм2 ВНИМАНИЕ Убедитесь, что предполагаемый ток КЗ на входных клеммах ИБП не будет превышать значение условного тока КЗ, указанного на паспортной табличке ИБП. Таблица.6 Минимальные рекомендуемые сечения кабелей и размеры предохранителей для внешнего аккумуляторного блока Номинал ИБП (кВт) Положительная и отрицательная линия [мм2] Предохранитель аккумулятора [A] Кабель заземления [мм2] Максимальное поперечное сечение проводника 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Рама 15/20 кВт, модель «C» и рама на 30/40 кВт с отдельным аккумулятором: одножильный провод: 25 мм2, многожильный провод с изоляционной трубкой: 16 мм2 Рама на 30/40 кВт с общим аккумулятором: одножильный провод: 90 мм2, многожильный провод с изоляционной трубкой: 70 мм2 Информация о номинальном и максимальном токе при номинальной мощности и напряжении приводится в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. При использовании дополнительного внешнего аккумулятора для обоих аккумуляторных блоков (шкафов) предусмотрены отдельные клеммы.2.3.1 ПРИМЕЧАНИЕ: Внешняя защита от сверхтоков не входит в комплект поставки данного изделия, но требуется согласно правилам установки электрического оборудования. Информации по требованиям к проводке приведена в Таблицах 4 и 5. Если требуется блокируемое устройство отключения выхода, его должен предоставить клиент. 77 RU Таблица 7. Моменты затяжки на клеммной колодке кабеля питания ИБП Рама ИБП 93PS 20 кВт Функция Момент затяжки Нм X1, X2, X3: L1, L2, L3, N 1.6 X4: аккумулятор +/PE (заземление) 93PS 40 кВт 6 X4: аккумулятор +/- 6 PE (заземление) 10 Нм для провода 16–35 мм2 6 Нм для провода 4–10 мм2 4 Нм для провода 2,5 мм2 X1 1.6 X2, X3 7 X4 3 PE (заземление) 10 Нм для провода 16–35 мм2 6 Нм для провода 4–10 мм2 4 Нм для провода 2,5 мм2 X1 6 X2, X3 17 X4 6 PE (заземление) 7 Нм (X1, X2, X3) 3.5 Нм (X4) 91PS 30 кВт 2.2.3 10 Нм для провода 16–35 мм2 6 Нм для провода 4–10 мм2 4 Нм для провода 2,5 мм2 X1, X2, X3: L1, L2, L3, N 91PS 15 кВт RU 3 Проверочный список по монтажу Действие Со шкафов снята вся упаковка и ограничители. Каждый шкаф системы ИБП размещен в месте установки. Зажимы заземления/крепежные элементы установлены между соединенными вместе шкафами. Вся проводка и кабели правильным образом подведены к ИБП и любым дополнительным шкафам. Все силовые кабели имеют правильный размер и правильным образом заделаны. Контакты нейтрали установлены или соединены с заземлением согласно требованиям. Заземление установлено правильным образом. Кабели аккумуляторов подведены и подключены к разъемам для аккумуляторов. Сигнальная проводка независимого выключателя и дополнительных контактов подключена от ИБП к прерывателю аккумулятора. Установлены отводы для линии LAN. Выполнена все соединения линии LAN. Системы кондиционирования воздуха установлены и работают правильным образом. 78 Да/нет Действие Да/нет Пространство вокруг установленной системы ИБП должно быть чистым и незапыленным (рекомендуется устанавливать ИБП на ровной поверхности, пригодной для установки компьютерного или электронного оборудования). Вокруг ИБП и других шкафов имеется достаточное рабочее пространство. В месте установки оборудования ИБП обеспечено достаточное освещение. На расстоянии не более 7,5 метров от оборудования ИБП имеется розетка 230 В переменного тока. Модуль удаленного аварийного отключения электропитания (REPO) установлен в требуемом месте, и его проводка подведена к клеммам внутри шкафа ИБП. При использовании в конфигурации НЗ выключателя EPO на него устанавливается перемычка между контактами 1 и 2. (ДОПОЛНИТЕЛЬНО) Аварийные реле и выводы сигнала подключены надлежащим образом. (ДОПОЛНИТЕЛЬНО) Модуль удаленного отключения аккумуляторов установлен в требуемом месте, и его проводка подведена к клеммам внутри ИБП и аккумуляторного шкафа. (ДОПОЛНИТЕЛЬНО) Дополнительное оборудование установлено в требуемых местах, и его проводка подведена к клеммам внутри шкафа ИБП. Запуск и эксплуатационная проверка выполнены сервисным инженером службы клиентской поддержки Eaton или квалифицированными специалистами, уполномоченными Eaton. 2.2.4 Распаковка и выгрузка ИБП На рисунках 9.1–9.8 показана процедура распаковки и выгрузки ИБП. Перед началом распаковки и выгрузки ИБП проверьте индикаторы TipNTell/DropNTell на поверхности упаковки. Если оборудование транспортировалось надлежащим образом в вертикальном положении, то индикаторы останутся в исходном состоянии. Если стрелка индикатора TipNTell полностью заполнилась синим цветом или головки стрелок индикатора DropNTell почернели, то свяжитесь с соответствующими сторонами и заявите о нарушениях при транспортировке. Для удобства транспортировки шкаф ИБП крепится болтами к деревянному поддону. Перед снятием шкафа с поддона перевезите его на место установки с помощью вилочного погрузчика или другой погрузочной техники. ПРЕДУПРЕЖДЕНИЕ Шкаф ИБП обладает большим весом. В случае нарушения инструкций по распаковке шкаф может опрокинуться, что может привести к серьезным травмам. Не наклоняйте шкаф ИБП более чем на 10 градусов от вертикального положения, чтобы он не опрокинулся. ПРИМЕЧАНИЕ: После снятия транспортировочных скоб немедленно уберите устройство с поддона. После снятия транспортировочных скоб и втягивания регулировочных ножек запрещается использовать вилочный погрузчик для транспортировки находящегося на поддоне устройства. Помните, что шкаф ИБП обладает большим весом, а в его нижней части имеются ролики. Для перемещения шкафа из места исходной установки на поддоне опустите регулировочные ножки так, чтобы шкаф перестал опираться на ролики. 79 RU 2.3 Установка системы ИБП Проводку для подключения ИБП к местному источнику питания должен предоставить оператор. Установка ИБП выполняется местным квалифицированным специалистом по электрооборудованию. К проверке установки и первому запуску ИБП, а также к установке дополнительного аккумуляторного шкафа допускаются только квалифицированные сервисные специалисты, уполномоченные Eaton ил уполномоченные сотрудники технической службы клиента. 2.3.1 Порядок установки ИБП На рисунках 10.1–10.5 показана процедура распаковки и выгрузки ИБП. Клеммы силового кабеля ИБП показаны на рисунках 6.1 (91PS, рама на 15 кВт), 6.2 (93PS, рама на 20 кВт), 7.1 (91PS, рама на 30 кВт с общей батареей), 7.2 (91PS, рама на 30 кВт с опциональной отдельной батареей), 8.1 (93PS, рама на 40 кВт с общей батареей) и 8.2 (93PS, рама на 40 кВт с опциональной отдельной батареей). X1 X2 Вход выпрямителя Вход байпаса X4/TB20 X3 Значение тока на выходе из ИБП TB21 X4/+ UPM2 Внешний аккумулятор + (отдельный аккумулятор) PE Внешний аккумулятор Автоматический выключатель внешнего аккумулятора Автоматический выключатель внешнего аккумулятора Защитное заземление Клеммы для связи ИБП показаны на рисунке 5.1 и 5.2. Кабель имеет следующие клеммы: 1. 2. 3. 4. TB11, не используется TB10, не используется TB9, не используется TB8, клемма для внешнего подключения CAN 5. TB7, внешняя сеть CAN 6. TB6, шина параллельного монтажа RU 2.3.2 7. USB1, USB-хост (при подключении к дополнительному оборудованию) 8. USB2, USB-устройство (при подключении к компьютеру) 9. MiniSlot 1 10. TB1, сигнальный вход 1–5 11. TB2, не используется 12. TB3, не используется 13. Последовательный COMпорт RS-232 14. MiniSlot 2 15. TB4, EPO 16. TB5, релейный выход Установка аккумуляторной системы При установке аккумуляторной системы, предоставленной клиентом, следует руководствоваться инструкциями к самой системе и прочими инструкциями производителя, а также применимыми национальными требованиями и нормативами. Технические характеристики аккумулятора приводятся в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 2.3.3 Проводка расцепителя аккумулятора Устройства ИБП 91PS/93PS 8–40 кВт стандартно оборудованы встроенным выключателем аккумулятора, который предназначен только для выключения встроенных аккумуляторов ИБП (за исключением модели «С», в которой встроенный выключатель может использоваться для выключения внешних аккумуляторов). Внешний выключатель аккумуляторов является важнейшим компонентом внешнего аккумуляторного шкафа или стойки, поэтому подлежит обязательной установке. При наличии внешнего выключателя аккумулятора очень важно обеспечить надлежащую систему сигнальных кабелей. При подаче питания на катушку шунтового расцепителя могут сработать (выключиться) как встроенные, так и внешние выключатели аккумуляторов. Питание (управляемое) катушек шунтовых расцепителей внешних выключателей аккумуляторов осуществляется 80 через разъемы TB20 и TB21 (TB21 имеется только в ИБП 8–40 кВт в конфигурации с отдельным аккумулятором). Напряжение по умолчанию на катушке шунтового расцепителя составляет 24 впост. тока. На рисунке 11 показана схема проводки расцепителя аккумулятора. Устройство состоит из следующих компонентов: A 1 2 2.3.4 Внешний выключатель аккумулятора Вывод 1, катушка шунтового расцепителя + Вывод 2, катушка шунтового расцепителя - 3 4 Вывод 3, вспомогательный контакт Вывод 4, возвратный вспомогательный контакт Установка внешнего аккумуляторного шкафа ИБП и подключение силовой проводки аккумулятора Инструкции по установке внешнего аккумуляторного шкафа и силовой проводки аккумулятора приводятся в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт и в руководстве по эксплуатации внешнего аккумуляторного шкафа. Выполните заземление внешнего аккумуляторного шкафа/собственной системы аккумуляторов на клемму защитного заземления 17. 2.3.5 Установка удаленного выключателя EPO Выключатель EPO подключается к разъему EPO на верхней передней панели устройств ИБП. Соединения для выключателя EPO показаны на рисунке 12. 2.3.6 Установка соединений интерфейса Информация по установке подключений интерфейса приводится в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 2.3.7 Универсальные релейные контакты В стандартный комплект поставки ИБП входит один универсальный релейный контакт. Также имеется аварийный контакт. Конфигурации выходных реле показаны на рисунке 13. Вы можете использовать нормально-замкнутый или нормально-разомкнутый контакт. Сигнал поступает тогда, когда состояние контакта изменяется с того состояния, которое вы определили, какнормальное. Вы можете подключить этот контакт к оборудованию на вашем объекте (например, к световой или звуковой сигнализации), которое будет информировать вас об аварийном сигнале на ИБП. ПРИМЕЧАНИЕ: Не допускайте работы контактов с током, превышающим 30 В переменного тока (RMS) и 30 В постоянного тока при 5 А. 2.3.8 Проводка в параллельных системах ИБП 91PS/93PS Информация по проводке в параллельных системах ИБП 91PS/93PS приводится в инструкциях по установке и эксплуатации ИБП Eaton 91PS/93PS 8–40 кВт. 81 RU 1 GEVAAR Belangrijke veiligheidsinstructies! Bewaar deze instructies! Dit document verschaft belangrijke veiligheidsinstructies en een korte instructie voor het controleren van de opbrengst van de UPS en het installeren van de UPS. Deze verkorte handleiding is uitsluitend bedoeld voor gebruik als installatiechecklist ter plaatse. De beoogde doelgroep van dit document bestaat uit ervaren vakmensen die de installatie van de UPS plannen en uitvoeren. GEVAAR Lees voordat u met de UPS aan het werk gaat de volledige installatie-instructies zoals verschaft in de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. De volledige instructies zijn beschikbaar voor downloaden via www.eaton.com/91psand93ps. Werkzaamheden aan de binnenzijde van de UPS moeten door een erkende Eaton klantenservicemonteur of door Eaton erkende gekwalificeerde servicemedewerkers worden uitgevoerd. De UPS bevat geen door de gebruiker te onderhouden onderdelen. De UPS werkt met netspanning, accuspanning of bypass-spanning. De UPS bevat componenten die hoge stroom en spanning voeren. Een goed geïnstalleerde behuizing is geaard en heeft een IP20-classificatie tegen elektrische schokken en vreemde voorwerpen. De UPS is echter een geavanceerd voedingssysteem en alleen gekwalificeerde medewerkers mogen de UPS installeren en servicewerkzaamheden hieraan uitvoeren. GEVAAR NL Deze UPS bevat dodelijke spanningen. Accu's kunnen door een hoge kortsluitstroom elektrische schokken of brandwonden veroorzaken. Tref de voorzorgsmaatregelen. Accu's kunnen HOGE SPANNINGEN en CORROSIEVE, GIFTIGE en EXPLOSIEVE stoffen bevatten. In verband met de accustreng kunnen de uitgangen onder hoogspanning staan, zelfs als de AC-voeding niet op de UPS is aangesloten. Lees de uitschakelinstructies in de Gebruikers- en Installatiehandleiding. WAARSCHUWING De UPS wordt door een eigen energiebron gevoed (accu's). De uitgangsaansluitklemmen kunnen onder spanning staan, zelfs als de UPS van een wisselstroomvoedingsbron is afgekoppeld. Installeer om het risico op brand of elektrische schokken te verlagen deze UPS binnenshuis in een omgeving waar temperatuur en vochtigheid worden geregeld en waar geen geleidende verontreinigde stoffen aanwezig zijn. Stapel de 91PS/93PS C-model UPS-kast niet op andere vergelijkbare kasten. Stapel niets op de 91PS/93PS UPS-kast. Gebruik bij installatie van de 91PS/93PS C-model UPS-kast op een plank de benodigde steunen om kantelen of vallen van de UPS te voorkomen. 82 WAARSCHUWING De omgevingstemperatuur mag niet hoger zijn dan 40 °C. Werk niet met de UPS in de buurt van water of bij een zeer hoge vochtigheid (maximaal 95%). Het systeem is niet bestemd voor gebruik buitenshuis. Controleer voordat u enige installatie- of onderhoudswerkzaamheden gaat uitvoeren of alle AC- en DC-voedingsbronnen zijn afgekoppeld. Voeding kan van meerdere bronnen afkomstig zijn. Zorg ook voor systeemaarding/PE-continuïteit van het systeem. In een parallel systeem kunnen uitgangsaansluitklemmen onder spanning staan, zelfs als de UPS is uitgeschakeld. Gevaar in verband met elektriciteit. Probeer om letsel te voorkomen niet de bedrading van de accu's of connectors te wijzigen. BELANGRIJK: Zorg dat voorafgaande aan de installatie alle accustrengen zijn afgekoppeld. PAS OP Uitsluitend hiervoor gekwalificeerde servicemedewerkers met kennis van accu's en de vereiste voorzorgsmaatregelen mogen installatie- of servicewerkzaamheden aan accu's uitvoeren. De werkzaamheden met betrekking tot het plaatsen en onderhouden van accu's worden uitgevoerd met spanningvoerende verbindingen en vereist gebruik van geïsoleerde gereedschappen. Houd onbevoegde medewerkers uit de buurt van de accu's. Neem voordat u accu's gaat installeren of vervangen alle aanwijzingen aangeduid met 'waarschuwing' en 'voorzichtig' alsook opmerkingen betreffende de juiste werkwijze in acht. Koppel de accu's niet af als de UPS in de accumodus staat. Zorg dat de vervangende accu's hetzelfde nummer en type hebben als de oorspronkelijk in de UPS geplaatste accu's. Meer nauwkeurige instructies vindt u op de UPS. Koppel voordat u accuklemmen gaat aansluiten of afkoppelen de voedingsbron af door de bijbehorende accubeveiliging te openen. Controleer of de accu niet onbedoeld is geaard. Verwijder als dit het geval is de aardingsbron. Bij aanraking van een willekeurig deel van een geaarde accu kunt u een elektrische schok krijgen. Voer de accu's volgens de lokale eisen af. Werp accu's niet in open vuur. Bij blootstelling aan vuur kunnen accu's exploderen. Sluit om het risico van brand te verlagen uitsluitend aan op een met ingangsbeveiligingen met maximumstroomwaarden uitgerust circuit volgens de nationale en plaatselijke installatievoorschriften. Houd om correcte luchtstroming voor koeling te verzekeren en medewerkers tegen gevaarlijke spanningen in de unit te beschermen de deur van de UPS gesloten en de voorpanelen geplaatst. Installeer of gebruik het UPS-systeem niet in de buurt van op gas of elektriciteit werkende warmtebronnen. Houd de bedrijfsomgeving binnen de in dit document genoemde parameters. Houd de omgeving van de UPS ordelijk, schoon en vrij van overmatig vocht. Neem alle aan de binnen- en buitenzijde van de apparatuur aangebrachte aanwijzingen met de aanduidingen GEVAAR, VOORZICHTIG en WAARSCHUWING in acht. 83 NL 2 De Eaton® 91PS/93PS uninterruptible power supply (UPS) is een werkelijk online, ononderbroken en geïntegreerd eenfase- (91PS) of driefasesysteem (93PS). Het levert geconditioneerde en ononderbroken wisselstroom aan een kritische last en beschermt deze tegen stroomuitval. Het uitgangsvermogen van de Eaton 91PS/93PS is gebaseerd op ononderbroken voedingsmodules (UPM's = uninterruptible power modules) van 15 kW of 20 kW. De 91PS/93PS is ook verkrijgbaar als C-model, bestaande uit het elektrische deel van het 91PS/93PS UPS 15/20 kW frame zonder accucompartiment. Tabel 1. Waarden UPS-kast UPS-frame Foto (Afbeelding 1) Aantal UPM's Waarden 91PS 15 kW A en B 1 8, 10, 15 kW 91PS 30 kW C 1 of 2 8, 10, 15, 20, 30 kW 93PS 20 kW A en B 1 8, 10, 15 of 20 kW 93PS 40 kW C 1 of 2 8, 10, 15, 20, 30 of 40 kW De belangrijkste onderdelen van de 91PS/93PS UPS 8-40 kW worden in afbeelding 2 weergegeven. De belangrijkste onderdelen zijn de volgende: 1. 2. 3. 4. NL . Bedieningspaneel Deurgrendel Voedingsmodule (UPM) Interne accu (niet in C-modellen) 5. 6. 7. 8. Communicatiecompartiment Ingangsschakelaar Accubeveiliging Bypass-schakelaar voor onderhoud (optioneel) GEVAAR Deze UPS bevat dodelijke spanningen. Werkzaamheden aan de binnenzijde van de UPS moeten door een erkende Eaton klantenservicemonteur of door Eaton erkende gekwalificeerde servicemedewerkers worden uitgevoerd. De UPS bevat geen door de gebruiker te onderhouden onderdelen. Zie voor de volledige veiligheidsinstructies de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. Installeer de UPS volgens de aanbevelingen in de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. Voer de volgende basisstappen voor installatie van de UPS in de gegeven volgorde uit: 84 1. 2. 3. 4. 5. 6. Stel een installatieplan voor het UPS-systeem op. Bereid de locatie op het UPS-systeem voor. Pak de UPS-kast uit en controleer deze. Laad de UPS-kast uit en installeer deze en bedraad het systeem. Vul de installatiechecklist in. Laat erkende servicemedewerkers de voorbereidende operationele controles en de opstart uitvoeren. OPMERKING: Opstarten en operationele controles moeten worden uitgevoerd door een erkende Eaton Klantenservicetechnicus of door Eaton erkende gekwalificeerde servicemedewerkers, anders komen de garantievoorwaarden zoals in de Garantie beschreven te vervallen. Lees voordat u het UPS-systeem gaat installeren de instructies en zorg dat u begrijpt hoe deze instructies van toepassing zijn op het door u te installeren systeem. Volg de verschafte procedures en afbeeldingen voor het opstellen van een logisch plan voor de installatie van het systeem. Voor werking van het UPS-systeem bij piekefficiëntie moet de installatielocatie aan de in de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding vermelde omgevingsparameters voldoen. De installatieomgeving moet aan de eisen betreffende het gewicht en de omvang van de UPS zoals gegeven in tabellen 2 en 3 voldoen. De afmetingen van de UPS-kast worden in afbeelding 1 weergegeven. Merk op dat de dieptemaat (750 mm) inclusief kabelwartels is. Tabel 2. Gewicht van UPS-kast met kartonnen verpakking NL C-model 8-20 kW (Afbeelding 1, foto A) 15/20 kW frame* (Afbeelding 1, foto B) 30/40 kW frame* (afbeelding 1, foto C) Transportgewicht 98 kg 293 kg 558 kg Geïnstalleerd gewicht 86 kg 280 kg 532 kg 310 kg/m2 1107 kg/m2 1478 kg/m2 Vloerbelasting * Merk op dat het maximumaantal interne accu’s bij alle modellen is inbegrepen. De UPS-kasten regelen de temperatuur van de interne componenten via geforceerde luchtkoeling. De kast bevat standaard luchtinlaten aan de voorzijde en uitlaten aan de achterzijde, zie afbeelding 3. Laat voor voldoende luchtcirculatie voor en achter iedere kast ruimte vrij. Zorg dat de koellucht die de UPS binnenkomt niet warmer is dan +40 °C. Zie voor ventilatie-eisen de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. 85 Tabel 3. Minimale vrije ruimte voor UPS-kast 15/20 kW frame (Afbeelding 1, foto’s A en B) 30/40 kW frame (Afbeelding 1, foto C) Vanaf de bovenzijde van de kast 500 mm 500 mm Vanaf de voorzijde van de kast 500 mm 650 mm Vanaf de achterzijde van de kast 150 mm 250 mm Vanaf de zijkant van de kast 0 mm 0 mm De aanbevolen omgevingstemperatuur voor bedrijf en vochtigheid voor het UPS-systeem wordt weergegeven in afbeeldingen 4.1 en 4.2. Een omgevingstemperatuur tussen +20 °C en +25 °C wordt aanbevolen voor een lange levensduur van de VRLA-accu's. Tabel 4. Minimaal aanbevolen maten voor de meeraderige kabel en de zekeringen voor de gelijkrichter, de bypassingangskabel en de UPS-uitgangskabel (driefase-ingang, driefaseuitgang) UPS-vermogen 93PS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Zekering gelijkrichter [A] 20 20 32 40 63 80 Zekering bypass [A] 20 20 32 40 63 80 PE-kabel [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] NL Maximumdoorsnede geleider 20 kW frame en 20 kW C-model: massieve draad 16 mm2, draadstrengen met bus: 10 mm 2 40 kW frame: massieve draad 70 mm2, draadstrengen met bus: 50 mm2 Tabel 5. Minimaal aanbevolen maten voor de meeraderige kabel en de zekeringen voor de gelijkrichter, de bypassingangskabel en de UPS-uitgangskabel (driefase-ingang, eenfaseuitgang) 86 UPS-vermogen 91PS (kW) 8 10 15 20 30 Gelijkrichterkabel [mm2]* 2,5 4 10 10 16 Zekering gelijkrichter [A] 20 20 32 40 63 Bypass, uitgangskabel [mm2] 10 16 25 35 70 Zekering bypass [A] 50 63 80 100 160 PE-kabel [mm2] 10 16 16 16 35 UPS-vermogen 91PS (kW) 8 10 15 20 30 Maximale doorsnede van de geleider, 15 kW frame en 15 kW C-model Gelijkrichter: massieve draad 16 mm2, draadstrengen met bus: 10 mm2 Bypass/uitgang: massieve draad 70 mm 2, draadstrengen met bus: 50 mm 2 Maximumdoorsnede geleider, 30 kW frame Gelijkrichter: massieve draad 70 mm2, draadstrengen met bus: 50 mm2 Bypass/uitgang: massieve draad 95 mm 2, draadstrengen met bus: 95 mm 2 PAS OP Zorg dat de verwachte kortsluitstroom die bij de ingangsaansluitklemmen van de UPS ontstaat gelijk is aan of minder is dan de op de typeplaat van de UPS vermelde voorwaardelijke kortsluitstroom. Tabel 6. Minimaal aanbevolen kabel- en zekeringmaten voor externe accu's UPS-vermogen (kW) Pos. & neg. lijn [mm2] Accuzekering [A] PE-kabel [mm2] Maximumdoorsnede geleider 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 15/20 kW frame, C-model en 30/40 kW frame met gescheiden accu: massieve draad: 25 mm2, draadstreng met bus: 16 mm2 30/40 kW frame met gemeenschappelijke accu: massieve draad: 90 mm2, draadstreng met bus: 70 mm2 Zie voor informatie over nominale en maximumstroomwaarden voor nominaal vermogen en spanning de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. Voor de optionele externe gescheiden accu zijn aparte aansluitklemmen voor beide accu's (kasten) beschikbaar. Zie paragraaf 2.3.1. OPMERKING: Dit product levert geen externe bescherming tegen overstroom, maar dit is wel vereist door de regelgeving. Zie tabellen 4 en 5 voor eisen met betrekking tot de bedrading. De gebruiker moet een eventueel vereiste vergrendelbare uitgangsafkoppeling leveren. Tabel 7. Aandraaimomenten van UPS voedingskabelaansluitingen UPS-frame Functie Vastdraaikoppel Nm 93PS 20 kW X1, X2, X3: L1, L2, L3, N 1.6 X4: accu +/PE (aarde) 93PS 40 kW 3 10 Nm voor 16-35 mm2 draad 6 Nm voor 4-10 mm2 draad 4 Nm voor 2,5 mm2 draad X1, X2, X3: L1, L2, L3, N 6 X4: accu +/- 6 87 NL UPS-frame Functie Vastdraaikoppel Nm PE (aarde) 10 Nm voor 16-35 mm2 draad 6 Nm voor 4-10 mm2 draad 4 Nm voor 2,5 mm2 draad X1 1.6 X2, X3 7 X4 3 PE (aarde) 10 Nm voor 16-35 mm2 draad 6 Nm voor 4-10 mm2 draad 4 Nm voor 2,5 mm2 draad X1 6 X2, X3 17 X4 6 91PS 15 kW 91PS 30 kW PE (aarde) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Handeling Alle verpakkingsmaterialen en bevestigingen zijn van alle kasten verwijderd. Alle kasten in het UPS-systeem staan op hun installatielocaties. Tussen alle kasten die met bouten aan elkaar worden bevestigd is een aardings/montageset geplaatst. Alle leidingen en kabels zijn correct naar de UPS en eventuele hulpkasten geleid. Alle voedingskabels hebben de juiste maten en zijn correct aangesloten. Neutrale geleiders zijn volgens de eisen geïnstalleerd of geaard. NL Een aardegeleider is op de juiste wijze geïnstalleerd. Accukabels zijn afgewerkt en op accuconnectors aangesloten. De shuntafschakeling van de accu en de bedrading van het AUX-contactsignaal zijn tussen de UPS en de accubeveiliging aangesloten. LAN-aansluitpunten zijn geïnstalleerd. Alle LAN-aansluitingen zijn tot stand gebracht. Airconditioningapparatuur is geïnstalleerd en werkt correct. Het gebied rondom het geïnstalleerde UPS-systeem is schoon en stofvrij (aanbevolen wordt om de UPS op een vlakke en voor computers of elektronische apparatuur geschikte vloer te plaatsen). Rondom de UPS en andere kasten is voldoende werkruimte aanwezig. Rondom alle UPS-apparatuur is voldoende verlichting aanwezig. Een 230 VAC stopcontact bevindt zich binnen 7,5 meter van de UPS-apparatuur. De voorziening voor uitschakeling van de externe voeding in noodsituaties (REPO = Remote Emergency Power-Off) is op de installatielocatie geïnstalleerd en de bedrading is in de UPS-kast aangesloten. Plaats bij gebruik van EPO in de NC-configuratie een jumper tussen pennen 1 en 2 op de EPO. (OPTIE) Alarmrelais en signaaluitgangen zijn correct bedraad. (OPTIE) Een externe besturing voor het afkoppelen van de accu is op de installatielocatie geplaatst en de bedrading hiervan is in de UPS- en accukast 88 Ja/Nee Handeling Ja/Nee aangesloten. (OPTIE) Accessoires zijn op de betreffende installatielocaties geplaatst en de bedrading is in de UPS-kast aangesloten. Het opstarten en de operationele controles worden door een erkende Eaton Klantenservicetechnicus of door Eaton erkende gekwalificeerde servicemedewerkers uitgevoerd. Het uitpakken en uitladen van de UPS wordt weergegeven in afbeeldingen 9.1-9.8. Controleer voordat u begint met het uitpakken en uitladen van de UPS de TipNTell en DropNTell indicatoren op de buitenzijde van de verpakking. Als de apparatuur correct in verticale positie is getransporteerd, moet de indicator intact zijn. Neem als de pijl van de TipNTell-indicator volledig blauw is geworden of de pijl(en) van de DropNTell-indicator zwart zijn contact op met de betreffende partijen om incorrect transport te melden. De UPS is voor transport met bouten op een houten pallet vastgezet. Verplaats voordat u de kast van de pallet verwijdert deze met een vorkheftruck of een ander hulpmiddel voor het verplaatsen van apparatuur naar de installatieruimte. WAARSCHUWING De UPS-kast is zwaar. Als de instructies voor het uitpakken niet nauwkeurig worden opgevolgd, kan de kast omvallen en ernstig letsel veroorzaken. Kantel de UPS-kast niet meer dan 10 graden uit de verticale stand om te voorkomen dat de kast omvalt. OPMERKING: Verplaats nadat u de transportbeugels heeft verwijderd de unit direct uit de buurt van de pallet. Gebruik nadat u de transportbeugels heeft verwijderd en de stelvoeten heeft ingetrokken geen vorkheftruck om de unit te verplaatsen terwijl deze nog op de pallet staat. Bedenk dat de UPS-kast zwaar is en dat zwenkwielen onder de kast aanwezig zijn. Breng als u de kast van zijn oorspronkelijke installatielocatie verwijdert en op een pallet naar een nieuwe locatie verplaatst de stelvoeten omlaag tot de kast niet op de zwenkwielen steunt en bevestig de transportbeugels aan de kast en de pallet. De gebruiker moet de bedrading voor aansluiting van de UPS op de lokale voedingsbron leveren. Laat de installatie van de UPS aan een lokale, gekwalificeerde elektricien over. Laat de installatie-inspectie, de eerste opstart van de UPS en de installatie van een extra accukast door een erkende Eaton klantenservicemonteur of door Eaton erkende servicemedewerkers uitvoeren. De installatie van de UPS wordt in afbeeldingen 10.1-10.5 weergegeven. De UPS-voedingskabelaansluitklemmen worden weergegeven in afbeeldingen 6.1 (91PS 15 kW frame), 6.2 (frame 93PS 20 kW), 7.1 (91PS 30kW frame met een gemeenschappelijke accu), 7.2 (91PS 30kW frame met een optionele gescheiden accu), 89 NL 8.1 (93PS 40kW frame met een gemeenschappelijke accu) en 8.2 (93PS 40kW frame met een optionele gescheiden accu). X1 X2 X3 X4/+ UPM2 Gelijkrichteringang Bypassingang UPS-uitgang Externe accu + (gescheiden accu) X4/TB20 TB21 PE Externe accu Afschakeling externe accu Afschakeling externe accu Beschermende aarde De UPS communicatieaansluitingen worden in afbeeldingen 5.1 en 5.2 weergegeven. De aansluitklemmen zijn als volgt: 1. 2. 3. 4. 5. 6. TB11, niet in gebruik TB10, niet in gebruik TB9, niet in gebruik TB8, externe CANafsluiting TB7, externe CAN TB6, Pull Chain-bus 7. USB1, USB-host (aansluiting op accessoires) 8. USB2, USB-apparaat (aansluiting op computer) 9. MiniSlot 1 10. TB1, signaalingang 1-5 11. TB2, niet in gebruik 12. TB3, niet in gebruik 13. Seriële COM-poort RS232 14. MiniSlot 2 15. TB4, EPO 16. TB5, relaisuitgang Plaats bij installatie van een door de klant geleverd accusysteem dit accusysteem volgens de aanwijzingen van de fabrikant van de accu en het accusysteem en volgens alle toepasselijke reglementen en voorschriften. Zie voor de accuspecificaties de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. De 91PS/93PS 8-40 kW UPS-units zijn altijd voorzien van een interne accustroomonderbreker die uitsluitend op de interne accu's van de UPS werkt (behalve bij het C-model, waar de interne accustroomonderbreker voor externe accu's kan worden gebruikt). De externe accubeveiliging is een cruciaal onderdeel van de externe accukast of het rek en moet hierin worden geplaatst. Bij de externe accubeveiliging is signaalbekabeling belangrijk. NL Zowel interne als externe accubeveiligingen kunnen afschakelen (uitschakelen) door de shuntafschakelspoel onder spanning te zetten. De shuntafschakelspoelen van de externe accustroomonderbrekers worden onder spanning gezet (bestuurd) via connectors TB20 en TB21 (TB21 uitsluitend beschikbaar in de 8-40 kW UPS met gescheiden accuconfiguratie). De standaardspanning van de shuntafschakelspoel is 24 VDC. De accu-afschakelbedrading wordt weergegeven in afbeelding 11. De onderdelen zijn de volgende: A 1 2 Externe accubeveiliging Pen 1, shuntafschakelspoel + Pen 2, shuntafschakelspoel - 3 4 Pin 3, AUX-contact Pin 4, AUX-contact retour Zie voor instructies betreffende de installatie van de externe accukast en accuvoedingsbekabeling de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding en de bij de externe accukast geleverde instructiehandleiding. Aard de kast voor de externe accu/het door de klant geleverde accusysteem op de PEaansluitklem 17. 90 De EPO wordt op het bovenste voorpaneel van de UPS op de EPO-connector aangesloten. De aansluitingen van de EPO-schakelaar worden in afbeelding 12 weergegeven. Zie voor de installatie van de interface-aansluitingen de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. Eén algemeen relaiscontact wordt als standaardoptie op de UPS geleverd. Ook is een alarmcontact aanwezig. De uitgangsrelaisconfiguraties worden in afbeelding 13 weergegeven. U kunt een normaal gesloten of normaal open contact gebruiken. Bij verandering van de staat van het contact die u als normaal heeft gespecificeerd, wordt een signaal gegenereerd. U kunt dit contact op apparatuur in uw pand (bijvoorbeeld een lampje of een alarmbel) aansluiten, zodat u weet wanneer een alarm op de UPS actief is. OPMERKING: Gebruik contacten niet bij een hogere spanning dan 30 VAC (RMS) en 30 VDC bij maximaal 5 A. Zie voor informatie over het bedraden van parallelle 91PS/93PS UPS-systemen de Eaton 91PS/93PS UPS 8-40 kW Gebruikers- en Installatiehandleiding. NL 91 1 PELIGRO ¡Instrucciones importantes de seguridad! ¡Conserve estas instrucciones! Este documento proporciona instrucciones importantes de seguridad y una breve instrucción sobre cómo examinar la entrega y cómo instalar el SAI. Esta guía rápida solo debe utilizarse como una lista de comprobación de instalación en el emplazamiento. La audiencia objetivo de este manual incluye a los profesionales que planifican y realizan la instalación del SAI. PELIGRO Antes de trabajar en el SAI, lea la totalidad de las instrucciones de instalación que se encuentran en la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. Las instrucciones completas se encuentran disponibles para su descarga en www.eaton.com/91psand93ps. Un ingeniero del servicio técnico de Eaton autorizado o personal de servicio cualificado y autorizado por Eaton se encarga de realizar las operaciones en el interior del SAI. El SAI no contiene piezas que puedan ser reparadas por el usuario. El SAI funciona con la red eléctrica, batería o alimentación de bypass. Contiene componentes con altas corrientes y tensión. Un alojamiento instalado adecuadamente se conecta a tierra y cuenta con certificación de protección IP20 con respecto a descargas eléctricas y objetos extraños. No obstante, el SAI es un sistema de alimentación sofisticado y solo debe instalarlo y mantenerlo personal cualificado. PELIGRO Este SAI contiene tensiones letales. Las baterías suponen un riesgo de descarga eléctrica o de quemaduras debido a corrientes altas de cortocircuito. Respete las precauciones. Las baterías podrían contener ALTAS TENSIONES y sustancias CORROSIVAS, TÓXICAS y EXPLOSIVAS. Debido a la cadena de baterías, los receptáculos de salida pueden transportar alta tensión incluso cuando el suministro de CA no está conectado al SAI. Lea las instrucciones de apagado en la Guía de usuario y de instalación. ES ADVERTENCIA El SAI recibe la alimentación de su propia fuente de energía (baterías). Los terminales de salida pueden estar energizados incluso si el SAI se ha desconectado de una fuente de CA. Para reducir el riesgo de incendio o descarga eléctrica, instale este SAI en un lugar interior con control de temperatura y humedad y sin contaminantes conductores. No apile el alojamiento modelo C del SAI 91PS/93PS encima de otros alojamientos similares. No apile nada encima del alojamiento del SAI 91PS/93PS. Si el alojamiento modelo C del SAI 91PS/93PS se instala en una estantería, utilice los soportes necesarios para impedir que el SAI vuelque o se caiga. 92 ADVERTENCIA La temperatura ambiente no debe superar 40 °C. No utilice el SAI cerca del agua o con una humedad excesiva (máximo de 95 %). El sistema no se ha diseñado para su uso en exteriores. Antes de realizar trabajos de instalación o mantenimiento, asegúrese de que todas las fuentes de alimentación de CA y CC estén desconectadas. La alimentación podría proceder de múltiples fuentes. Asegúrese de la continuidad de PE / conexión a tierra del sistema. En un sistema paralelo, los terminales de salida pueden estar energizados incluso si el SAI se ha desconectado. Peligro de energía eléctrica. Para evitar lesiones, no intente modificar ningún conector o cable de la batería. IMPORTANTE: Asegúrese de desconectar todas las ramas de baterías antes de la instalación. PRECAUCIÓN Las tareas de instalación o mantenimiento en las baterías solo pueden ser realizadas por personal de servicio técnico cualificado conocedor de las baterías y de las precauciones requeridas. La instalación y el trabajo de servicio en las baterías es trabajo en línea con corriente y requiere el uso de herramientas de tensión. Mantenga alejado de las baterías al personal no autorizado. Antes de instalar o sustituir las baterías, tenga en cuenta todas las advertencias, precauciones y notas relativas a la manipulación adecuada. No desconecte las baterías mientras el SAI se encuentre en el modo Batería. Asegúrese de que las baterías de repuesto sean de la misma gama y modelo que la batería instalada originalmente en el SAI. Puede consultar instrucciones más precisas en el SAI. Antes de conectar o desconectar terminales de batería, desconecte la fuente de carga abriendo el disyuntor de la batería correspondiente. Examine si la batería se ha conectado a tierra involuntariamente. Si es así, retire la fuente de la tierra. El contacto con cualquier parte de una batería conectada a tierra puede provocar riesgo de descarga eléctrica. Deseche las baterías de conformidad con los requisitos locales de eliminación. No arroje las baterías al fuego. Las baterías pueden explotar cuando se exponen a las llamas. Para reducir el riesgo de incendio, realice la conexión solo a un circuito proporcionado con la corriente nominal máxima del disyuntor de entrada de acuerdo con las normas de instalación nacionales y locales. Mantenga la puerta del SAI cerrada y los paneles frontales instalados para garantizar una corriente de aire de refrigeración adecuada y proteger al personal de tensiones peligrosas dentro de la unidad. No instale ni haga funcionar el sistema SAI cerca de fuentes de calefacción de gas o eléctricas. Mantenga el entorno de funcionamiento dentro de los parámetros especificados en este documento. Mantenga el entorno del SAI despejado, limpio y exento de humedad excesiva. Respete todos los avisos de PELIGRO, PRECAUCIÓN y ADVERTENCIA fijados en el interior y exterior de los equipos. 93 ES 2 El Sistema de alimentación ininterrumpida (SAI) Eaton® 91PS/93PS es un sistema monofásico (91PS) o trifásico (93PS), de estado sólido, de doble conversión, sin transformadores, de servicio continuo, en línea real. Suministra alimentación CA adaptada e ininterrumpible a la carga crítica y la protege de fallos de la alimentación. Las potencias nominales de salida del Eaton 91PS/93PS se basan en módulos de alimentación ininterrumpida (UPM) con una potencia nominal de 15 kW o 20 kW. El 91PS/93PS también se encuentra disponible como un modelo C, que consta de la sección eléctrica del bastidor de 15/20 kW del SAI 91PS/93PS sin el compartimento de la batería. Tabla 1. Potencias nominales del alojamiento del SAI Bastidor del SAI Imagen (Ilustración 1) Número de UPMs Potencias nominales 91PS 15 kW AyB 1 8, 10, 15 kW 91PS 30 kW C 1ó2 8, 10, 15, 20, 30 kW 93PS 20 kW AyB 1 8, 10, 15 o 20 kW 93PS 40 kW C 1ó2 8, 10, 15, 20, 30 o 40 kW Las piezas principales del SAI 91PS/93PS 8-40 kW se muestran en la ilustración 2. Las piezas principales son las siguientes: 1. 2. 3. 4. . ES Panel de control Cerrojo de la puerta Módulo de alimentación (UPM) Batería interna (no en modelos C) 5. 6. 7. 8. Área de comunicaciones Conmutador de entrada Señales del disyuntor Conmutador de bypass de mantenimiento (opcional) PELIGRO Este SAI contiene tensiones letales. Un ingeniero del servicio técnico de Eaton autorizado o personal de servicio cualificado y autorizado por Eaton se encarga de realizar las operaciones en el interior del SAI. El SAI no contiene piezas que puedan ser reparadas por el usuario. Para conocer las instrucciones de seguridad completas, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. El SAI debe instalarse de acuerdo con las recomendaciones en la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. Use la siguiente secuencia básica de pasos para instalar el SAI: 94 1. 2. 3. 4. 5. 6. Elabore un plan de instalación para el sistema SAI. Prepare su emplazamiento para el sistema SAI. Inspeccione y desembale el alojamiento del SAI. Descargue e instale el alojamiento del SAI y realice el cableado del sistema. Complete la lista de comprobación de la instalación. Disponga de personal de servicio técnico autorizado para realizar las comprobaciones operativas preliminares y el arranque. NOTA: Solo un Ingeniero de servicio técnico de Eaton autorizado o personal de servicio cualificado y autorizado por Eaton deberá realizar el arranque y las comprobaciones operativas ya que de lo contrario los términos de la garantía especificados en la Garantía dejarán de tener validez. Antes de instalar el sistema SAI, lea y entienda cómo se aplican estas instrucciones en el sistema que va a instalar. Utilice los procedimientos e ilustraciones proporcionados para elaborar un plan lógico para instalar el sistema. Para que el sistema SAI funcione con la máxima eficiencia, el emplazamiento de instalación debe cumplir los parámetros ambientales descritos en la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. El entorno de instalación debe cumplir los requisitos de peso y tamaño del SAI proporcionados en las Tablas 2 y 3. Las dimensiones del alojamiento del SAI se muestran en la ilustración 1. Tenga en cuenta que la dimensión de profundidad (750 mm) incluye los prensa cables. Tabla 2. Pesos del alojamiento del SAI con embalaje de cartón Modelo C 8-20 kW (Ilustración 1, imagen A) Bastidor de 15/20 kW* (Ilustración 1, imagen B) Bastidor de 30/40 kW* (Ilustración 1, imagen C) Peso de envío 98 kg 293 kg 558 kg Peso instalado 86 kg 280 kg 532 kg Carga del suelo 310 kg/m2 1107 kg/m2 1478 kg/m2 ES * Se incluyen baterías internas máximas con todos los modelos. Los alojamientos del SAI utilizan refrigeración forzada por circulación de aire para regular la temperatura interna de los componentes. De forma predeterminada, las entradas de aire se encuentran en la parte delantera y las salidas se encuentran en la parte posterior del alojamiento; consulte la ilustración 3. Deje holgura en la parte frontal y por detrás de cada alojamiento para que se produzca una circulación de aire adecuada. Asegúrese de que el aire de refrigeración que penetra en el SAI no supere +40 °C. Para conocer los requisitos de ventilación, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. 95 Tabla 3. Holguras mínimas del alojamiento del SAI Bastidor de 15/20 kW (Ilustración 1, imágenes A y B) Bastidor de 30/40 kW (Ilustración 1, imagen C) Desde la parte superior del alojamiento 500 mm 500 mm Desde la parte frontal del alojamiento 500 mm 650 mm Desde la parte posterior del alojamiento 150 mm 250 mm 0 mm 0 mm Desde la parte lateral del alojamiento La temperatura ambiente de funcionamiento y la humedad recomendadas para el sistema SAI se muestran en las ilustraciones 4.1 y 4.2. Se recomienda una temperatura ambiente de +20 °C a +25 °C para obtener una vida útil prolongada de las baterías VRLA. Tabla 4. Cable multiconductor mínimo recomendado y tamaños de fusibles para la entrada del rectificador y de bypass y cables de salida del SAI (entrada trifásica, salida trifásica) Potencia nominal del SAI 93PS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Fusible del rectificador [A] 20 20 32 40 63 80 Fusible de bypass [A] 20 20 32 40 63 80 Cable PE [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Cable [mm2] Sección transversal máxima del conductor ES Bastidor de 20 kW y modelo C de 20 kW: cable macizo de 16 mm 2, cable trenzado con férula: 10 mm 2 Bastidor de 40kW: cable macizo de 70 mm 2, cable trenzado con férula: 50 mm2 Tabla 5. Cable multiconductor mínimo recomendado y tamaños de fusibles para la entrada del rectificador y de bypass y cables de salida del SAI (entrada trifásica, salida monofásica) Potencia nominal del SAI 91PS (kW) 96 8 10 15 20 30 Cable del rectificador [mm2] 2,5 4 10 10 16 Fusible del rectificador [A] 20 20 32 40 63 Bypass, cable de salida [mm2] 10 16 25 35 70 Fusible de bypass [A] 50 63 80 100 160 Potencia nominal del SAI 91PS (kW) 8 10 15 20 30 Cable PE [mm2] 10 16 16 16 35 Sección transversal máxima del conductor, bastidor de 15 kW y modelo C de 15 kW Rectificador: cable macizo de 16 mm2, cable trenzado con férula: 10 mm2 Bypass/salida: cable macizo de 70 mm 2, cable trenzado con férula: 50 mm2 Sección transversal máxima del conductor, bastidor de 30 kW Rectificador: cable macizo de 70 mm2, cable trenzado con férula: 50 mm2 Bypass/salida: cable macizo de 95 mm 2, cable trenzado con férula: 95 mm2 PRECAUCIÓN Asegúrese de que la corriente de cortocircuito potencial resultante en los terminales de entrada del SAI sea igual o inferior que la corriente de cortocircuito condicional declarada en la etiqueta de clasificación del SAI. Tabla 6. Tamaños mínimos recomendados de cable y de fusible para banco de batería externa Valores nominales del SAI (kW) Línea pos. y neg. [mm2] Fusible de batería [A] Cable PE [mm2] Sección transversal máxima del conductor 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Bastidor de 15/20 kW, modelo C y bastidor de 30/40 kW con batería independiente: cable macizo: 25 mm2, cable trenzado con férula: 16 mm2 Bastidor de 30/40 kW con batería común: cable macizo: 90 mm 2, cable trenzado con férula: 70 mm 2 Si desea información sobre las corrientes nominales y máximas para la potencia y tensión nominal, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. Para la opción de batería separada externa, hay terminales separados para ambos bancos de la batería (alojamientos), consulte la sección 2.3.1. NOTA: La protección externa de supresión de sobretensiones no se proporciona con este producto, aunque las normas la exigen. Consulte las Tablas 4 y 5 para conocer los requisitos de cableado. Si se requiere un dispositivo de desconexión bloqueable de la salida, éste será suministrado por el usuario. 97 ES Tabla 7. Pares de apriete de terminales de cable de alimentación del SAI Bastidor del SAI 93PS 20 kW Función Par de apriete Nm X1, X2, X3: L1, L2, L3, N 1.6 X4: batería +/PE (tierra) 93PS 40 kW 91PS 15 kW 91PS 30 kW 3 10 Nm para cable de 16-35 mm2 6 Nm para cable de 4-10 mm2 4 Nm para cable de 2,5 mm2 X1, X2, X3: L1, L2, L3, N 6 X4: batería +/- 6 PE (tierra) 10 Nm para cable de 16-35 mm2 6 Nm para cable de 4-10 mm2 4 Nm para cable de 2,5 mm2 X1 1.6 X2, X3 7 X4 3 PE (tierra) 10 Nm para cable de 16-35 mm2 6 Nm para cable de 4-10 mm2 4 Nm para cable de 2,5 mm2 X1 6 X2, X3 17 X4 6 PE (tierra) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Acción Todos los materiales y elementos de sujeción del embalaje se han retirado de cada alojamiento. ES Cada alojamiento del sistema SAI se ha colocado en su posición predeterminada de instalación. Se ha instalado un kit de conexión a tierra / kit de montaje del alojamiento entre los alojamientos que se hayan fijado juntos con pernos. Todos los conductos y cables se han tendido adecuadamente hasta el SAI y hasta cualquier alojamiento auxiliar. Todos los cables de alimentación están dimensionados y terminados adecuadamente. Los conductores de neutro están instalados y unidos a tierra según los requisitos. Se ha instalado adecuadamente un conductor de puesta a tierra. Los cables de la batería se terminan y conectan a los conectores de la batería. El cableado de señal del contacto auxiliar y de disparo de la batería está conectado desde el SAI hasta el disyuntor de la batería. Los cables LAN están instalados. Todas las conexiones LAN se han completado. Los equipos de aire acondicionado están instalados y funcionan correctamente. 98 Sí/No Acción Sí/No El área que rodea al sistema SAI instalado está limpia y libre de polvo (se recomienda instalar el SAI en un suelo nivelado adecuado para los equipos informáticos o electrónicos). Hay un espacio de trabajo adecuado en torno al SAI y a otros alojamientos. Se proporciona iluminación adecuada en torno a todos los equipos del SAI. Una toma de corriente de 230 VCA se encuentra dentro de una distancia de 7,5 metros de los equipos del SAI. El dispositivo de apagado remoto de emergencia (REPO) está montado en su posición predeterminada de instalación y su cableado termina dentro del alojamiento del SAI. Si el EPO se utiliza en la configuración NC, debe instalarse un puente en el EPO entre los pines 1 y 2. (OPCIONAL) Los relés de alarma y las salidas de señal están cableados adecuadamente. (OPCIONAL) Existe un control de desconexión remota de la batería montado en su posición predeterminada de instalación y su cableado termina dentro del alojamiento del SAI y de la batería. (OPCIONAL) Los accesorios están montados en sus posiciones predeterminadas de instalación y el cableado termina dentro del alojamiento del SAI. Un ingeniero del servicio técnico de Eaton autorizado o un ingeniero de servicio cualificado y autorizado por Eaton se encarga de realizar el arranque y las comprobaciones operativas. El desembalaje y la descarga del SAI se muestran en las ilustraciones 9.1 - 9.8. Antes de empezar a desembalar y descargar el SAI, compruebe los indicadores TipNTell y DropNTell de la superficie del embalaje. Si el equipo se ha transportado correctamente en la posición vertical, los indicadores deben estar intactos. Si la flecha indicadora TipNTell se ha vuelto toda azul o las puntas de flecha del indicador DropNTell están negras, contacte con las partes correspondientes para notificar un transporte inadecuado. Con fines de transporte, el alojamiento del SAI está fijado con pernos a un palé de madera. Antes de descargar el alojamiento del palé, utilice una carretilla elevadora u otro equipo de manipulación de materiales para mover el alojamiento hasta la zona de instalación. ADVERTENCIA ES El alojamiento del SAI es pesado. Si no se respetan estrictamente las instrucciones de desembalaje, el alojamiento podría volcar y provocar lesiones graves. No incline el alojamiento del SAI más de 10 grados desde la vertical o el alojamiento podría volcar. NOTA: Tras retirar los soportes de envío, saque la unidad inmediatamente del palé. Tras retirar los soportes de envío y replegar los pies de nivelación, no utilice una carretilla elevadora para mover la unidad mientras aún se encuentre en el palé. Tenga en cuenta que el alojamiento del SAI es pesado y que existen ruedas giratorias bajo el alojamiento. Si retira el alojamiento de su posición predeterminada de instalación original y se lleva a una nueva posición sobre un palé, baje los pies de nivelación hasta que el alojamiento deje de descansar en las ruedas giratorias y fije los soportes de envío al alojamiento y al palé. 99 El operador tiene que suministrar el cableado para conectar el SAI a la fuente de alimentación local. La instalación del SAI debe realizarla un electricista cualificado localmente. La inspección de la instalación y el arranque inicial del SAI, así como la instalación de un alojamiento de batería adicional, deben realizarse mediante un ingeniero del servicio técnico de Eaton autorizado o personal de servicio cualificado y autorizado por Eaton. La instalación del SAI se muestra en las ilustraciones 10.1-10.5. Los terminales de cables de alimentación del SAI se muestran en las ilustraciones 6.1 (91PS bastidor de 15 kW), 6.2 (93PS bastidor de 20 kW), 7.1 (91PS bastidor de 30kW con una batería común), 7.2 (91PS bastidor de 30kW con una opción de batería separada), 8.1 (93PS bastidor de 40kW con una batería común) y 8.2 (93PS bastidor de 40kW con una opción de batería separada). X1 X2 X3 X4/+ UPM2 Entrada del rectificador Entrada de bypass Salida del SAI Batería externa + (batería separada) X4/TB20 TB21 PE Batería externa Disparo de batería externa Disparo de batería externa Tierra de protección Los terminales de comunicación del SAI se muestran en las ilustraciones 5.1 y 5.2. Los terminales son los siguientes: 1. 2. 3. 4. 5. 6. TB11, no se utiliza TB10, no se utiliza TB9, no se utiliza TB8, terminación CAN externa TB7, CAN externa TB6, bus de cadena de tracción 7. USB1, host USB (conexión a accesorios) 8. USB2, dispositivo USB (conexión a ordenador) 9. MiniSlot 1 10. TB1, entrada de señal 1-5 11. TB2, no se utiliza 12. TB3, no se utiliza 13. Puerto COM de serie RS232 14. MiniSlot 2 15. TB4, EPO 16. TB5, salida de relé Si instala un sistema de batería suministrado por el cliente, realice la instalación siguiendo las instrucciones del fabricante de la batería y del sistema de batería, así como todas las normas y códigos nacionales aplicables. ES Para conocer las especificaciones de la batería, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. Las unidades SAI 91PS/93PS 8-40 kW siempre están equipadas con un disyuntor de batería interna, que afecta solo a las baterías internas del SAI (excepto para el modelo C, donde el disyuntor de batería interna puede utilizarse para baterías externas). El disyuntor de batería externa es una parte crucial del alojamiento o bastidor de la batería externa y debe colocarse en el mismo. Con el disyuntor de batería externa, el cableado de señal es importante. Tanto los disyuntores de batería interna como externa pueden dispararse (desactivarse) energizando la bobina de disparo. Las bobinas de disparo de los disyuntores de batería externa se energizan (controlan) mediante los conectores TB20 y TB21 (TB21 disponible solo en el SAI de 8-40 kW con configuración de batería independiente). La tensión predeterminada de la bobina de disparo es 24 VCC. 100 El cableado de disparo de la batería se muestra en la ilustración 11. Las piezas son las siguientes: A 1 Disyuntor de batería externa Pin 1, bobina de disparo + 2 Pin 2, bobina de disparo - 3 4 Pin 3, contacto AUX Pin 4, retorno de contacto AUX Si desea instrucciones sobre la instalación del alojamiento de la batería externa y el cableado de alimentación de la batería, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW y el manual de instrucciones que se proporciona con el alojamiento de la batería externa. Conecte a tierra el alojamiento de la batería externa / sistema de batería suministrado por el cliente al terminal PE 17. El EPO se conecta en el panel frontal superior del SAI, en el conector del EPO. Las conexiones del conmutador EPO se muestran en la ilustración 12. Si desea información sobre la instalación de las conexiones de la interfaz, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. En el SAI se proporciona un contacto de relé de propósito general como función estándar. También se proporciona un contacto de alarma. Las configuraciones del relé de salida se muestran en la ilustración 13. Puede utilizar un contacto normalmente cerrado o normalmente abierto. Si el estado del contacto cambiara con respecto al estado especificado como normal, se emitirá una señal. Puede conectar este contacto a los equipos de su instalación (como por ejemplo una indicación luminosa o un timbre de alarma) para permitirle saber cuándo se activa una alarma en el SAI. NOTA: A los contactos no se les debe aplicar una tensión y corriente que superen 30 VCA (RMS) y 30 VCC a 5 A. ES Si desea información sobre el cableado en paralelo de sistemas SAI 91PS/93PS, consulte la Guía de usuario y de instalación del SAI Eaton 91PS/93PS 8-40 kW. 101 1 NEBEZPEČÍ Důležité bezpečnostní pokyny! Uschovejte tuto příručku! Tato příručka obsahuje důležité bezpečnostní pokyny a stručné pokyny, jak zkontrolovat dodané zařízení UPS a jak jej správně nainstalovat. Tato rychlá příručka má sloužit jako kontrolní seznam v místě instalace. Cílovou skupinou této příručky jsou zkušení odborníci, kteří plánují a provádějí instalaci zařízení UPS. NEBEZPEČÍ Před zahájením prací na zařízení UPS si přečtěte pokyny k instalaci, které jsou uvedeny v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS UPS 8-40 kW. Celé znění pokynů si můžete stáhnout z adresy www.eaton.com/91psand93ps. Zásahy uvnitř zařízení UPS musí provádět autorizovaný servisní technik společnosti Eaton nebo kvalifikovaný servisní personál pověřený společností Eaton. Uvnitř UPS nejsou žádné součásti, které může opravit či vyměnit uživatel. UPS pracuje s napájením ze sítě, z baterií či přes bypass. Obsahuje součásti, kterými protékají vysoké proudy a na kterých se vyskytuje nebezpečné napětí. Správně instalovaný UPS je uzemněn a zajišťuje ochranu proti úrazu elektrickým proudem a vniknutí cizích předmětů se stupněm krytí IP20. Zařízení UPS je nicméně sofistikovaný napájecí systém a jeho instalaci a servis smí provádět pouze kvalifikovaní pracovníci. NEBEZPEČÍ Zařízení UPS pracuje s životu nebezpečným napětím. Baterie představují nebezpečí úrazu elektrickým proudem či popálením v důsledku velkého zkratového proudu. Dodržujte bezpečnostní opatření. Baterie mohou obsahovat VYSOKÉ NAPĚTÍ a AGRESIVNÍ, TOXICKÉ či VÝBUŠNÉ látky. Kvůli řetězci baterií může být na výstupních svorkách vysoké napětí, i když není zařízení UPS připojeno ke zdroji střídavého napětí. Přečtěte si pokyny k vypnutí, které jsou uvedeny v Instalační a uživatelské příručce. CS VAROVÁNÍ Zařízení UPS je napájeno vlastním zdrojem energie (bateriemi). Výstupní svorky mohou být pod napětím, i když je zařízení UPS odpojeno od zdroje střídavého napětí. Abyste snížili riziko požáru či úrazu elektrickým proudem, instalujte toto zařízení UPS do vnitřních prostor s regulovanou teplotou a vlhkostí a bez výskytu vodivých prachových částic. Nepokládejte zařízení skříňový model zařízení UPS 91PS/93PS C na žádné další podobné skříňky. Nepokládejte rovněž nic na skříň zařízení UPS 91PS/93PS. Pokud skříňový model UPS 91PS/93PS C instalujete na regál, použijte nezbytné podpěry, kterými zabráníte pádu nebo převrácení zařízení UPS. 102 VAROVÁNÍ Okolní teplota nesmí překročit 40 °C. Nepoužívejte UPS v blízkosti vody či při nadměrné vlhkosti (nejvýše 95 %). Systém není určen pro použití ve venkovním prostředí. Než zahájíte jakékoli instalační či servisní práce, zkontrolujte, zda jsou odpojeny zdroje střídavého i stejnosměrného napájení. Napájení může přicházet z několika zdrojů. Též je třeba zajistit uzemnění systému a spojitost vodiče PE. U systému s paralelním zapojením mohou být výstupní svorky pod napětím, i když je zařízení UPS vypnuté. Nebezpečí úrazu elektrickým proudem. Abyste předešli zraněním, nepokoušejte se upravovat ani opravovat žádné vodiče ani konektory baterií. DŮLEŽITÉ: Před instalací se ujistěte, že jste odpojili všechny řetězce baterií. POZOR Instalovat baterie a provádět jejich servis smějí pouze kvalifikovaní servisní pracovníci se zkušenostmi s bateriemi a potřebnými opatřeními. Instalace a servisní práce na bateriích probíhají na živých částech a vyžadují používání nástrojů pro práci pod napětím. Zamezte přístupu neoprávněných osob k bateriím. Při instalaci a výměně baterií pamatujte na všechna varování, upozornění a poznámky týkající se správné manipulace s nimi. Neodpojujte baterie, je-li UPS v bateriovém režimu. Zkontrolujte, zda jsou náhradní baterie stejného typu a počtu jako baterie, které byly v UPS původně instalovány. Přesnější pokyny jsou uvedeny na UPS. Před připojením či odpojením bateriových svorek odpojte nabíjecí zdroj. Provedete to rozpojením příslušného jističe bateriového obvodu. Zkontrolujte, zda není baterie neúmyslně uzemněna. Pokud ano, uzemnění odstraňte. Kontakt s libovolnou částí uzemněné baterie představuje nebezpečí úrazu elektrickým proudem. Baterie likvidujte v souladu s místními předpisy. Nevhazujte baterie do ohně. Jsou-li vystaveny ohni, mohou explodovat. Abyste snížili riziko požáru, připojujte zařízení pouze k obvodu vybavenému jističem maximálního vstupního proudu dimenzovaným v souladu s národními a místními elektroinstalačními předpisy podle údajů, které obsahuje. Abyste zajistili správný tok chladicího vzduchu a chránili osoby před nebezpečným napětím uvnitř zařízení, udržujte dveře UPS zavřené a přední panely namontované. CS Neinstalujte ani neprovozujte systém UPS v blízkosti plynových ani elektrických topidel. Dbejte na to, aby provozní prostředí odpovídalo parametrům uvedeným v tomto dokumentu. Okolí UPS udržujte bez nepořádku, čisté a bez nadměrné vlhkosti. Věnujte pozornost všem symbolům NEBEZPEČÍ, POZOR a VAROVÁNÍ umístěným uvnitř a vně zařízení. 103 2 Nepřerušitelný záložní zdroj Eaton® 91PS/93PS (UPS) je kontinuální beztransformátorový energeticky nezávislý jednofázový (91PS) nebo třífázový (93PS) systém s technologií online a dvojitou konverzí. Dodává upravený nepřerušovaný střídavý proud (AC) kritické zátěží a chrání ji před výpadky proudu. Jmenovité výkony zařízení Eaton řady 91PS/93PS jsou založeny na modulech nepřerušovaného napájení (UPM) o jmenovitém výkonu 15 kW nebo 20 kW. Model 91PS/93PS je rovněž v dispozici jako skříňový model C, který obsahuje elektrickou část rámu 91PS/93PS UPS 15/20 kW bez prostoru na baterie. Tabulka 1. Parametry skříně UPS Rám UPS Obrázek (Ilustrace 1) Počet UPM Technické údaje 91PS 15 kW AaB 1 8, 10, 15 kW 91PS 30 kW C 1 nebo 2 8, 10, 15, 20, 30 kW 93PS 20 kW AaB 1 8, 10, 15 nebo 20 kW 93PS 40 kW C 1 nebo 2 8, 10, 15, 20, 30 nebo 40 kW Hlavní části modelu 91PS/93PS 8-40 kW UPS jsou uvedeny na obrázku 2. Hlavní části: 1. 2. 3. 4. . 5. 6. 7. 8. Ovládací panel Západka dveří Výkonový modul (UPM) Interní baterie (nejsou ve skříňovém modelu C) Komunikační rozhraní Spínač vstupu Bateriový jistič Spínač údržbového bypassu (volitelný) NEBEZPEČÍ Zařízení UPS pracuje s životu nebezpečným napětím. Zásahy uvnitř zařízení UPS musí provádět autorizovaný servisní technik společnosti Eaton nebo kvalifikovaný servisní personál pověřený společností Eaton. Uvnitř UPS nejsou žádné součásti, které může opravit či vyměnit uživatel. CS Kompletní bezpečnostní pokyny naleznete v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. Zařízení UPS je třeba instalovat podle doporučení uvedených v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. Při instalaci zařízení UPS dodržujte následující základní postup: 1. 104 Vytvořte si plán instalace systému UPS. 2. 3. 4. 5. 6. Připravte pro systém UPS své prostory. Zkontrolujte a vybalte skříň UPS. Vyjměte a nainstalujte skříň UPS a systém zapojte. Vyplňte kontrolní seznam pro instalaci. Požádejte pověřené pracovníky servisu, aby provedli kontrolu před spuštěním a samotné spuštění. POZNÁMKA: Úvodní a provozní revize musí provádět technik zákaznické péče společnosti Eaton nebo kvalifikovaný personál pověřený společností Eaton, jinak pozbývají platnosti záruční podmínky uvedené v Záruce. Před instalací systému UPS si přečtěte tyto pokyny a ujistěte se, že rozumíte jejich souvislosti s vámi instalovaným systémem. Podle postupů a ilustrací sestavte logický postup instalace systému. Aby systém UPS pracoval co nejefektivněji, musí místo instalace splňovat parametry prostředí uvedené v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. Prostředí místa instalace musí splňovat hmotnostní a rozměrová doporučení pro zařízení UPS uvedená v tabulce 2 a 3. Rozměry skříně UPS jsou uvedeny na obrázku 1. Mějte na paměti, že hloubkové rozměry (750 mm) jsou včetně kabelových průchodek. Tabulka 2. Hmotnost skříně UPS v kartonovém obalu Model C 8-20 kW (Ilustrace 1, obr. A) rám 15/20 kW* (Ilustrace 1, obr. B) Přepravní hmotnost 98 kg 293 kg 558 kg Hmotnost po instalaci 86 kg 280 kg 532 kg 310 kg/m2 1107 kg/m2 1478 kg/m2 Zatížení podlahy 30/40 kW rám* (Ilustrace 1, obr. C) * U všech modelů jsou započteny interní baterie maximální možné kapacity. Skříně UPS používají nucené chlazení vzduchem, které reguluje teplotu vestavěných součástí. Otvory pro nasávání vzduchu jsou standardně na přední straně skříně a výfukové otvory jsou na zadní straně, jak ukazuje obrázek 3. Kvůli řádnému proudění vzduchu musí být před a za každou skříní dostatek volného prostoru. Ujistěte se, že chladicí vzduch vstupující do zařízení UPS nemá vyšší teplotu než +40°C. Požadavky na ventilaci jsou uvedeny v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. 105 CS Tabulka 3. Minimální požadované volné místo kolem skříně UPS rám 15/20 kW (Ilustrace 1, obr. A a B) rám 30/40 kW (Ilustrace 1, obr. C) Nad skříní 500 mm 500 mm Před skříní 500 mm 650 mm Za skříní 150 mm 250 mm 0 mm 0 mm Po stranách skříně Doporučená teplota a vlhkost okolního prostředí pro systém UPS je uvedena na obrázku 4.1 a 4.2. Doporučujeme zajistit teplotu prostředí v rozsahu od +20 °C do +25 °C. Dosáhnete tak dlouhé životnosti baterií VRLA. Tabulka 4. Minimální doporučený průřez vícevodičového kabelu, dimenzování pojistky pro usměrňovač a bypass a průřez kabelu pro výstup z UPS (3fázový vstup, 3fázový výstup) 93PS výkon UPS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Pojistka usměrňovače [A] 20 20 32 40 63 80 Pojistka bypassu [A] 20 20 32 40 63 80 Kabel PE [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] Maximální průřez vodiče 20kW rám a 20kW skříňový model: pevný vodič 16 mm 2, spletený vodič s ochranným kroužkem: 10 mm2 40kW rám: pevný vodič 70 mm2, spletený vodič s ochranným kroužkem: 50 mm2 Tabulka 5. Minimální doporučený průřez vícevodičového kabelu, dimenzování pojistky pro usměrňovač a bypass a průřez kabelu pro výstup z UPS (3-fázový vstup, 1-fázový výstup) CS 91PS výkon UPS (kW) 8 10 15 20 30 Kabel usměrňovače [mm2] 2,5 4 10 10 16 Pojistka usměrňovače [A] 20 20 32 40 63 Bypass, kabel výstupu [mm2] 10 16 25 35 70 Pojistka bypassu [A] 50 63 80 100 160 Kabel PE [mm2] 10 16 16 16 35 Maximální průřez vodiče, 15 kW rám a 15 kW model C 106 Usměrňovač: pevný vodič 16 mm2, spletený vodič s ochranným kroužkem: 10 mm2 Bypass/výstup: pevný vodič 70 mm 2, spletený vodič s ochranným kroužkem: 50 mm2 91PS výkon UPS (kW) Maximální průřez vodiče, 30 kW rám 8 10 15 20 30 Usměrňovač: pevný vodič 70 mm2, spletený vodič s ochranným kroužkem: 50 mm2 Bypass/výstup: pevný vodič 95 mm 2, spletený vodič s ochranným kroužkem: 95 mm2 POZOR Zkontrolujte, zda případný zkratový proud na vstupních svorkách UPS je menší či roven podmíněnému zkratovému proudu uvedeném na typovém štítku UPS. Tabulka 6. Minimální doporučený průřez kabelu a dimenzování pojistky pro externí baterie Výkon UPS (kW) Kladný a záporný vodič [mm2] Pojistka baterie [A] Kabel PE [mm2] Maximální průřez vodiče 8 10 15 20 30 40 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 15/20 kW rám, model C a 30/40 kW rám se samostatnou baterií: pevný vodič: 25 mm2, spletený vodič s ochranným kroužkem: 16 mm2 30/40 kW rám se společnou baterií: pevný vodič: 90 mm 2, spletený vodič s ochranným kroužkem: 70 mm2 Informace o jmenovitých a maximálních proudech a napětí jsou uvedeny v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. Pro možnost použití externí samostatné baterie, je zařízení vybaveno samostatnými svorkami pro obě baterie (skříně), viz oddíl 2.3.1. POZNÁMKA: Externí nadproudová ochrana není součástí tohoto produktu, předpisy ji však vyžadují. Požadavky na kabeláže viz Tabulka 4 a 5. Pokud je vyžadováno uzamykatelné zařízení pro odpojení výstupu, musí jej zajistit uživatel sám. Tabulka 7. Utahovací momenty pro svorky napájecích kabelů UPS Rám UPS 93PS 20 kW Funkce Utahovací moment (Nm) X1, X2, X3: L1, L2, L3, N 1.6 X4: Externí baterie +/PE (uzemnění) 93PS 40 kW 3 10 Nm pro vodič 16-35 mm2 6 Nm pro vodič 4-10 mm2 4 Nm pro vodič 2,5 mm2 X1, X2, X3: L1, L2, L3, N 6 X4: Externí baterie +/- 6 PE (uzemnění) 10 Nm pro vodič 16-35 mm2 6 Nm pro vodič 4-10 mm2 4 Nm pro vodič 2,5 mm2 107 CS Rám UPS 91PS 15 kW 91PS 30 kW Funkce Utahovací moment (Nm) X1 1.6 X2, X3 7 X4 3 PE (uzemnění) 10 Nm pro vodič 16-35 mm2 6 Nm pro vodič 4-10 mm2 4 Nm pro vodič 2,5 mm2 X1 6 X2, X3 17 X4 6 PE (uzemnění) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Činnost Ze skříně byl odstraněn veškerý balicí materiál a přepravní držáky. Všechny skříně systému UPS byly umístěny na místo instalace. Mezi všemi skříněmi, které mají být sešroubovány dohromady, bylo instalováno uzemnění / montážní sada. Všechna vedení a kabely mezi zařízením UPS a pomocnými skříněmi jsou řádně instalovány. Všechny napájecí kabely jsou správně dimenzované a mají správné zakončení. Nulové vodiče jsou instalovány a uzemněny podle požadavků. Zemnicí vodič je řádně instalován. Kabely baterií jsou zakončeny a připojeny ke svorkám. Mezi UPS a bateriovým jističem je zapojena kabeláž ovládání cívky vypínače a pomocného signalizačního kontaktu. Je instalován přívod LAN. Byla provedena všechna připojení LAN. Klimatizace je řádně zapojená a funguje správně. Prostor v místě instalace systému UPS je čistý a bezprašný (doporučujeme umístit UPS na rovnou podlahu vhodnou pro počítače či elektronická zařízení). Okolo skříně UPS a ostatních skříní je dostatek prostoru. Veškerá zařízení systému UPS jsou dostatečně osvětlena. CS Nejdále ve vzdálenosti 7,5 metru od zařízení UPS je k dispozici zásuvka s napájením 230 VAC. Zařízení REPO (Dálkové nouzové vypnutí) je namontováno na svém místě a vedení od něj je zapojeno do skříně UPS. Je-li spínač EPO (nouzové vypnutí) použit jako rozpínací kontakt, je mezi piny 1 a 2 spínače EPO instalována propojka. (VOLITELNĚ) Relé alarmu a signálové vstupy jsou řádně zapojeny. (VOLITELNĚ) Dálkové ovládání bateriového jističe je namontováno na správném místě a vedení je zapojeno do skříně s UPS a baterií. (VOLITELNĚ) Příslušenství a jeho kabeláž jsou namontovány a připojeny do skříně UPS. Úvodní a provozní revize provádí autorizovaný technik péče o zákazníky společnosti Eaton nebo kvalifikovaný servisní technik pověřený společností Eaton. 108 Ano/Ne Rozbalení a vyložení zařízení UPS je znázorněno na obrázku 9.1 – 9.8. Než začnete UPS vybalovat, zkontrolujte indikátory TipNTell a DropNTell na povrchu obalu. Pokud bylo zařízení převáženo správně ve svislé poloze, měly by být indikátory neporušené. Pokud šipka ukazatele TipNTell zcela zmodrá nebo bude hlava či hlavy ukazatele DropNTell černé, spojte se s příslušnou stranou a nahlaste nesprávnou přepravu. Během přepravy je skříň UPS přišroubována k dřevěné paletě. Než skříň z palety sundáte, přesuňte ji pomocí paletového vozíku či jiné manipulační techniky na místo instalace. VAROVÁNÍ Skříň UPS je těžká. Pokud se nebudete přesně držet pokynů pro rozbalování, může dojít k jejímu převrácení a následně k vážnému zranění. Nenaklánějte skříň UPS o více než 10° od vertikální roviny, jinak se může převrátit. POZNÁMKA: Poté, co přepravní konzoly odstraníte, zařízení okamžitě přesuňte z palety. Po odstranění přepravních konzol a zatažení vyrovnávacích nohou se zařízením, dokud je ještě na paletě, nemanipulujte pomocí vysokozdvižného vozíku. Skříň UPS je těžká a zespodu je opatřena pojezdovými kolečky. Pokud skříň z místa původní instalace přesouváte na nové místo a transportujete ji na paletě, vysuňte vyrovnávací nohy tak, aby skříň neležela na kolečkách, a připojte ke skříni a paletě přepravní konzole. Zákazník musí zajistit kabeláž pro připojení zařízení UPS k místnímu zdroji napájení. Instalaci UPS musí provádět elektrikář s kvalifikací podle místních předpisů. Kontrolu instalace a prvotní spuštění zařízení UPS včetně instalace externí bateriové skříně smí provádět pouze autorizovaný servisní technik společnosti Eaton nebo kvalifikovaný servisní personál pověřený společností Eaton. Instalace zařízení UPS je znázorněna na obrázku 10.1-10.5. Svorkovnice napájecích kabelů zařízení UPS jsou znázorněny na obrázky 6.1 (rám 91PS 15 kW), 6.2 (rám 93PS 20 kW), 7.1 (rám 91PS 30kW se společnou baterií), 7.2 (rám 91PS 30kW s možností samostatné baterie), 8.1 (rám 93PS 40kW se společnou baterií) a 8.2 (rám 93PS 40kW s možností samostatné baterie). X1 X2 X3 X4/+ UPM2 Vstup usměrňovače Vstup bypassu Výstup UPS Externí baterie + (samostatná baterie) X4/TB20 TB21 PE Externí baterie Vypnutí externí baterie Vypnutí externí baterie Ochranné uzemnění 109 CS Komunikační svorkovnice zařízení UPS jsou popsány na obrázku 5.1 a 5.2. Svorkovnice: 1. 2. 3. 4. 5. 6. TB11, nepoužito TB10, nepoužito TB9, nepoužito TB8, zakončení externí CAN TB7, externí CAN TB6, sběrnice paralelní komunikace 7. USB1, USB host (připojení k počítači) 8. USB2, USB device (připojení k počítači) 9. MiniSlot 1 10. TB1, signální vstup 1–5 11. 12. 13. 14. 15. 16. TB2, nepoužito TB3, nepoužito Sériový port COM RS-232 MiniSlot 2 TB4, EPO TB5, výstup relé Pokud provádíte instalaci bateriového systému dodaného zákazníkem, instalujte jej podle pokynů jeho výrobce, výrobce baterií a v souladu se všemi příslušnými předpisy a zákony. Specifikace baterie naleznete v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. Zařízení UPS 91PS/93PS 8-40 kW jsou vždy vybavena jističem interní baterie, který má vliv pouze na interní baterie zařízení UPS (s výjimkou skříňového modelu C, u kterého lze jistič interní baterie použít také pro externí baterie). Jistič externích baterií je velmi důležitou součástí skříně nebo racku s externími bateriemi a musí v něm být umístěn. U jističe externích baterií je důležité připojení signálních kabelů. Jističe interních i externích baterií lze aktivovat (rozepnout) připojením napětí na cívku jejich jističe. Cívky externích bateriových jističů jsou napájeny (řízeny) přes konektory TB20 a TB21 (konektor TB21 je obsažen pouze v zařízení UPS 8–40 kW se samostatnou konfigurací baterie). Standardní napětí cívky je 24 VDC. Zapojení vypínací cívky je uvedeno na obrázku 11. Jednotlivé části: A 1 Externí bateriový jistič Pin 1, vypínací cívka + 2 Pin 2, vypínací cívka - 3 4 Pin 3, pomocný kontakt Pin 4, zpětný vodič pomocného kontaktu Pokyny k instalaci skříně externí baterie a jejího připojení naleznete v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS a příručce s pokyny, která byla dodána spolu se skříní externí baterie. Skříň externí baterie či zákazníkem dodaný bateriový systém uzemněte na svorku PE 17. CS Spínač EPO je připojen k přednímu hornímu panelu zařízení UPS ke konektoru označenému EPO. Přípojky spínače EPO jsou uvedeny na obrázku 12. Informace o instalaci přípojek rozhraní naleznete v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. 110 Standardní součástí zařízení UPS je jeden univerzální reléový kontakt. K dispozici je také kontakt alarmu. Konfigurace výstupního relé jsou uvedeny na obrázku 13. Lze jej použít jako spínací či rozpínací kontakt. Pokud se stav kontaktu změní ze stavu, který jste stanovili jako normální, je vyslán signál. Tento kontakt můžete připojit k zařízení ve vašich prostorách (například ke světelné signalizaci nebo ke zvukovému alarmu), které vás poté varuje, že došlo k alarmu na zařízení UPS. POZNÁMKA: Kontakty nepoužívejte, pokud napětí přesahuje 30 VAC (efektivně) nebo 30 VDC při max. 5 A. Informace o systémech 91PS/93PS UPS s paralelní elektroinstalací naleznete v Instalační a uživatelské příručce k zařízení Eaton 91PS/93PS 8-40 kW UPS. CS 111 1 NIEBEZPIECZEŃSTWO Ważne wskazówki bezpieczeństwa! Te instrukcje należy zachować! Ten dokument zawiera ważne instrukcje bezpieczeństwa oraz krótką instrukcję dotyczącą kontroli dostawy jednostki UPS oraz sposobu jej montażu. Skrócona instrukcja powinna być wykorzystywana wyłącznie jako lista kontrolna w miejscu montażu. Dokument skierowany jest do doświadczonych profesjonalistów, którzy planują i wykonują montaż jednostki UPS. NIEBEZPIECZEŃSTWO Przed wykonaniem prac przy jednostce UPS należy przeczytać wszystkie instrukcje dotyczące montażu zawarte w instrukcji obsługi i montażu Eaton 91PS/93PS UPS 8-40 kW. Pełne instrukcje są dostępne do pobrania na stronie www.eaton.com/91psand93ps. Prace wewnątrz jednostki UPS może wykonywać upoważniony technik serwisu firmy Eaton lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton. Wewnątrz jednostki UPS nie ma żadnych elementów nadających się do serwisowania przez użytkownika. Jednostka zasilająca UPS może pracować z następującymi źródłami zasilania: sieciowym, bateryjnym lub obejściowym (układ bypassu). Zawiera podzespoły, które znajdują się pod wysokim napięciem i przewodzą prąd o dużym natężeniu. Prawidłowo zamontowana szafa jest uziemiona i zapewnia stopień ochrony IP20 przed porażeniem elektrycznym i przenikaniem materiałów obcych. Jednostka UPS jest zaawansowanym systemem zasilania i powinna być montowana oraz serwisowana wyłącznie przez wykwalifikowany personel. NIEBEZPIECZEŃSTWO W tej jednostce UPS występują napięcia o wartościach zagrażających życiu. Baterie stwarzają ryzyko porażenia prądem elektrycznym lub oparzenia wywołanych prądem zwarcia o wysokim natężeniu. Należy przestrzegać środków ostrożności. Baterie zawierają ŻRĄCE, TRUJĄCE i WYBUCHOWE substancje. Są też źródłem WYSOKIEGO NAPIĘCIA. Z powodu zestawu baterii gniazdo wyjściowe może być pod wysokim napięciem, nawet jeśli źródło prądu przemiennego nie jest podłączone do jednostki UPS. Proszę przeczytać instrukcje dotyczące wyłączania zawarte w instrukcji obsługi i montażu. OSTRZEŻENIE Jednostka UPS jest zasilana przez własne źródło energii (baterie). Na zaciskach wyjściowych może być obecne napięcie nawet wtedy, gdy jednostka UPS jest odłączona od źródła prądu przemiennego. Aby zmniejszyć ryzyko powstania pożaru lub porażenia prądem elektrycznym, jednostkę UPS należy instalować w środowisku o kontrolowanej temperaturze i wilgotności, wewnątrz budynku. PL Nie kłaść szafy UPS 91PS/93PS model C na górze żadnej innej podobnej szafy. Nie kłaść żadnych przedmiotów na górze szafy UPS 91PS/93PS. Jeśli szafa UPS 91PS/93PS model C jest zamontowana na półce, należy użyć odpowiednich podpór, aby uchronić jednostkę UPS przed przechyleniem lub upadkiem. 112 OSTRZEŻENIE Temperatura otoczenia nie może przekraczać 40 °C. Jednostki UPS nie należy eksploatować w pobliżu wody lub w miejscu o nadmiernej wilgotności (maksymalnie 95%). Urządzenie nie jest przeznaczone do użytkowania na zewnątrz budynków. Przed rozpoczęciem dowolnych prac montażowych lub serwisowych należy upewnić się, że urządzenie zostało odłączone od wszystkich źródeł zasilania prądem zmiennym (AC) i stałym (DC). Zasilanie może pochodzić z wielu źródeł. Należy również zapewnić ciągłość uziemienia/przewodu ochronnego systemu. W systemie równoległym na zaciskach wyjściowych może być obecne napięcie nawet wtedy, gdy jednostka UPS jest wyłączona. Zagrożenie ze strony energii elektrycznej. Aby uniknąć obrażeń ciała, nie podejmować prób zmiany żadnych przewodów lub złączy baterii. WAŻNE: Przed montażem należy zapewnić odłączenie wszystkich zestawów baterii. PRZESTROGA Montaż baterii lub związane z nimi prace serwisowe mogą wykonywać wykwalifikowani pracownicy serwisu posiadający wiedzę w zakresie baterii i wymaganych środków ostrożności. Prace montażowe i serwisowe na bateriach są wykonywane pod napięciem, dlatego też wymagają zastosowania specjalnych narzędzi. Nieupoważniony personel nie może mieć z bateriami jakiejkolwiek styczności. Przed montażem lub wymianą baterii należy zapoznać się ze wszystkimi ostrzeżeniami, przestrogami i uwagami dotyczącymi prawidłowej obsługi. Nie odłączać baterii, gdy UPS pracuje w trybie Baterii. Należy upewnić się, że nowa bateria ma ten sam numer i jest tego samego typu, co bateria oryginalnie zainstalowana w jednostce UPS. Dokładne instrukcje znajdują się na jednostce UPS. Przed podłączeniem lub odłączeniem zacisków baterii należy odłączyć źródło ładowania przez otwarcie wyłącznika obwodu baterii. Sprawdzić, czy bateria nie została uziemiona w sposób niezamierzony. Jeśli tak, należy usunąć źródło uziemienia. Dotknięcie jakiejkolwiek części uziemionej baterii może stanowić zagrożenie porażeniem prądem elektrycznym. Baterie należy utylizować zgodnie z lokalnymi wymaganiami w zakresie utylizacji. Nie wrzucać baterii do ognia. Wystawienie baterii na działanie ognia może spowodować wybuch. Aby zmniejszyć ryzyko pożaru, połączenie należy wykonać wyłącznie do obwodu wyposażonego w odłącznik wejściowy o wartości znamionowej prądu, zgodnie z obowiązującymi krajowymi i lokalnymi zasadami instalacji. Drzwi UPS powinny być przez cały czas zamknięte, a przednie panele zamontowane, aby zapewnić właściwy przepływ powietrza chłodzącego i chronić personel przed niebezpiecznym napięciem obecnym wewnątrz jednostki. Nie wolno montować ani eksploatować systemu UPS w pobliżu źródeł gazu lub ciepła wytwarzanego przez prąd elektryczny. Parametry środowiska pracy należy utrzymywać w granicach podanych w tym dokumencie. Otoczenie jednostki UPS musi być uporządkowane, czyste i wolne od nadmiernej wilgoci. Stosować się do wszystkich tabliczek NIEBEZPIECZEŃSTWO, PRZESTROGA i OSTRZEŻENIE umieszczonych wewnątrz i na zewnątrz sprzętu. 113 PL 2 Zasilacz bezprzerwowy (UPS) 91PS/93PS firmy Eaton® to prawdziwy beztransformatorowy o podwójnej konwersji, stały, jednofazowy (91PS) lub trójfazowy (93PS) system online do pracy ciągłej. Dostarcza ustabilizowane i bezprzerwowe zasilanie prądu zmiennego do krytycznego obciążenia i chroni go przed awariami zasilania. Znamionowa moc wyjściowa systemu 91PS/93PS firmy Eaton zależy od liczby bezprzerwowych modułów zasilających (UPM), z których każdy ma moc 15 kW lub 20 kW. 91PS/93PS jest również dostępny jako model C, który składa się z części elektrycznej ramy zwymiarowanej do mocy 15/20kW systemu UPS 91PS/93PS bez przedziału na baterie. Tabela 1. Wartości znamionowe szafy UPS Rama systemu UPS Rysunek (Ilustracja 1) Liczba UPM Wartości znamionowe 91PS 15 kW AiB 1 8, 10, 15 kW 91PS 30 kW C 1 lub 2 8, 10, 15, 20, 30 kW 93PS 20 kW AiB 1 8, 10, 15 lub 20 kW 93PS 40 kW C 1 lub 2 8, 10, 15, 20, 30 lub 40 kW Główne części systemu UPS 91PS/93PS 8-40 kW przedstawia rysunek 2. Główne części to: 1. 2. 3. 4. . Panel sterowania Zamek drzwi Moduł zasilania (UPM) Bateria wewnętrzna (brak w modelach C) 5. 6. 7. 8. Obszar komunikacyjny Przełącznik wejściowy Odłącznik baterii Przełącznik bypassu serwisowego (opcjonalny) NIEBEZPIECZEŃSTWO W tej jednostce UPS występują napięcia o wartościach zagrażających życiu. Prace wewnątrz jednostki UPS może wykonywać upoważniony technik serwisu firmy Eaton lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton. Wewnątrz jednostki UPS nie ma żadnych elementów nadających się do serwisowania przez użytkownika. W celu uzyskania kompletnych instrukcji bezpieczeństwa proszę odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. UPS musi być zamontowany zgodnie z zaleceniami zawartymi w instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. PL Wykonaj poniższe czynności, aby zamontować UPS: 114 1. 2. 3. 4. 5. 6. Utwórz plan montażu systemu UPS. Przygotuj miejsce montażu systemu UPS. Sprawdź i rozpakuj szafę UPS. Rozładuj szafę UPS i zamontuj ją, a następnie podłącz okablowanie. Wypełnij listę kontrolną przy instalacji. Upoważniony personel serwisu powinien przeprowadzić wstępną kontrolę i uruchomienie. UWAGA: Kontrole przy uruchomieniu i eksploatacji muszą być wykonywane przez upoważnionego technika serwisu firmy Eaton lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton. W innym wypadku zostaną unieważnione warunki gwarancji. Przed przystąpieniem do montażu systemu UPS należy przeczytać i zrozumieć instrukcje, które odnoszą się do montowanego systemu. Do utworzenia logicznego planu instalacji systemu należy wykorzystać dostarczone procedury oraz rysunki. Aby zapewnić maksymalną sprawność systemu UPS, parametry środowiskowe miejsca montażu muszą być zgodne z wartościami podanymi w instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. Środowisko montażu musi spełniać wymagania dotyczące masy i rozmiaru UPS zawarte w tabelach 2 i 3. Wymiary systemu UPS przedstawia rysunek 1. Należy zauważyć, że wymiar głębokości (750 mm) zawiera dławiki kablowe. Tabela 2. Wartości ciężaru szafy UPS z opakowaniem kartonowym Model C 8-20 kW (Ilustracja 1, rysunek A) Rama 15/20 kW* (Ilustracja 1, rysunek B) Rama 30/40 kW* (Ilustracja 1, rysunek C) Ciężar wysyłkowy 98 kg 293 kg 558 kg Ciężar po montażu 86 kg 280 kg 532 kg Obciążenie podłoża 310 kg/m2 1107 kg/m2 1478 kg/m2 * Wszystkie modele są wyposażone w maksymalną liczbę baterii wewnętrznych. W szafach UPS zastosowano układ wymuszonego chłodzenia powietrzem w celu kontrolowania temperatury podzespołów wewnętrznych. Wloty powietrza standardowo znajdują się z przodu szafy, a wyloty z tyłu. Patrz rysunek 3. W celu uzyskania poprawnego obiegu powietrza, z przodu i z tyłu każdej szafy musi być wystarczająca ilość miejsca. Upewnić się, że temperatura powietrza chłodzącego wchodzącego do jednostki UPS nie przekracza +40 °C. W celu zapewnienia wymogów wentylacji należy odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. 115 PL Tabela 3. Minimalna ilość wolnego miejsca dookoła szafy UPS Rama 15/20 kW* (Ilustracja 1, rysunki A i B) Rama 30/40 kW* (Ilustracja 1, rysunek C) Nad szafą 500 mm 500 mm Przed szafą 500 mm 650 mm Za szafą 150 mm 250 mm 0 mm 0 mm Z boku szafy Zalecana temperatura i wilgotność robocza otoczenia dla systemu UPS przedstawiają rysunki 4.1 i 4.2. Aby uzyskać długą żywotność baterii VRLA zalecane jest utrzymywanie temperatury otoczenia w zakresie od +20 °C do +25 °C. Tabela 4. Minimalne parametry kabli wielożyłowych i bezpieczników dla prostownika i wejścia bypassu oraz wyjściowych przewodów systemu UPS (wejście trójfazowe, wyjście trójfazowe) Moc znamionowa systemu UPS 93PS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Bezpiecznik prostownika [A] 20 20 32 40 63 80 Bezpiecznik układu bypassu [A] 20 20 32 40 63 80 Kabel PE [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Kabel [mm2] Maksymalny przekrój przewodu Rama 20 kW i model C 20 kW: przewód drutowy 16 mm 2, standardowy przewód z tulejką: 10 mm 2 Rama 40kW: przewód drutowy 70 mm2, standardowy przewód z tulejką: 50 mm2 Tabela 5. Minimalne parametry kabli wielożyłowych i bezpieczników dla prostownika i wejścia bypassu oraz wyjściowych przewodów systemu UPS (wejście trójfazowe, wyjście jednofazowe) PL 116 Moc znamionowa systemu UPS 91PS (kW) 8 10 15 20 30 Przewód prostownika [mm2] 2,5 4 10 10 16 Bezpiecznik prostownika [A] 20 20 32 40 63 Obejście, przewód wyjściowy [mm2] 10 16 25 35 70 Bezpiecznik układu bypassu [A] 50 63 80 100 160 Kabel PE [mm2] 10 16 16 16 35 Moc znamionowa systemu UPS 91PS (kW) 8 10 15 20 30 Maksymalny przekrój przewodu, rama 15 kW i model C 15 kW Prostownik: przewód drutowy 16 mm2, standardowy przewód z tulejką: 10 mm2 Obejście/wyjście: przewód drutowy 70 mm 2, standardowy przewód z tulejką: 50 mm 2 Maksymalny przekrój przewodu, rama 30 kW Prostownik: przewód drutowy 70 mm2, standardowy przewód z tulejką: 50 mm2 Obejście/wyjście: przewód drutowy 95 mm 2, standardowy przewód z tulejką: 95 mm 2 PRZESTROGA Należy zapewnić, aby ewentualny prąd zwarcia na zaciskach wejściowych systemu UPS był niższy lub równy warunkowemu prądowi zwarcia podanemu na tabliczce znamionowej systemu UPS. Tabela 6. Minimalne parametry kabli i bezpieczników przeznaczonych dla zewnętrznego zestawu baterii Moc znamionowa systemu UPS (kW) 8 10 15 20 30 40 Linia dodatnia i ujemna [mm2] 1*16 1*16 1*16 1*16 1*35 1*35 Bezpiecznik baterii [A] 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Kabel PE [mm2] Maksymalny przekrój przewodu Rama 15/20 kW, model C i rama 30/40 kW z osobną baterią: przewód drutowy: 25 mm2, standardowy przewód z tulejką: 16 mm2 Rama 30/40 kW ze wspólna baterią: przewód drutowy: 90 mm 2, standardowy przewód z tulejką: 70 mm 2 Aby uzyskać więcej informacji o znamionowych i maksymalnych natężeniach dla znamionowej mocy i napięcia, należy odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 840 kW firmy Eaton. W przypadku opcji oddzielnej baterii zewnętrznej dla obu zestawów baterii (szaf) są dostępne oddzielne zaciski, patrz punkt 2.3.1. UWAGA: Zewnętrzne zabezpieczenie nadprądowe nie jest wbudowane w tym urządzeniu, ale jest wymagane w ramach przepisów. Wymagania dotyczące okablowania można znaleźć w tabelach 4 i 5. Jeśli jest wymagany odłącznik na wyjściu z możliwością blokowania, jego instalacja należy do obowiązków użytkownika. PL Tabela 7. Momenty dokręcania zacisków kabli zasilających systemu UPS Rama systemu UPS 93PS 20 kW Funkcja Moment dokręcania Nm X1, X2, X3: L1, L2, L3, N 1.6 X4: bateria +/- 3 117 Rama systemu UPS 93PS 40 kW Funkcja Moment dokręcania Nm PE (uziemienie) 10 Nm dla przewodu 16-35 mm2 6 Nm dla przewodu 4-10 mm2 4 Nm dla przewodu 2,5 mm2 X1, X2, X3: L1, L2, L3, N 6 X4: bateria +/- 6 PE (uziemienie) 10 Nm dla przewodu 16-35 mm2 6 Nm dla przewodu 4-10 mm2 4 Nm dla przewodu 2,5 mm2 X1 1.6 X2, X3 7 X4 3 PE (uziemienie) 10 Nm dla przewodu 16-35 mm2 6 Nm dla przewodu 4-10 mm2 4 Nm dla przewodu 2,5 mm2 X1 6 X2, X3 17 X4 6 PE (uziemienie) 7 Nm (X1, X2, X3) 3.5 Nm (X4) 91PS 15 kW 91PS 30 kW Czynność Wszystkie materiały opakowaniowe i mocowania zostały zdjęte z każdej szafy. Każda szafa w systemie UPS znajduje się w miejscu montażu. Zamontowano zestaw montażowy/zestaw uziemienia szafy pomiędzy wszystkimi szafami, które są razem skręcone. Wszystkie kanały i kable są poprawnie poprowadzone do UPS i wszystkich szaf pomocniczych. Wszystkie kable zasilające mają właściwy przekrój poprzeczny i są prawidłowo zakończone. Przewody neutralne są zamontowane i podłączone do uziemienia zgodnie z wymogami. Przewód uziemienia został prawidłowo zamontowany. Przewody baterii są zakończone i podłączone do złączy baterii. Przewód sygnału wyzwalania wzrostowego napięciowego baterii i przewód styku pomocniczego z UPS należy podłączyć do odłącznika baterii. Zamontowano linie odgałęźne sieci LAN. PL Wszystkie połączenia LAN zostały wykonane. System klimatyzacji został zainstalowany i działa prawidłowo. Przestrzeń wokół zainstalowanego systemu UPS jest uporządkowana i oczyszczona z kurzu (zalecane jest, aby system UPS został zainstalowany na poziomej posadzce, odpowiedniej dla urządzeń komputerowych i elektronicznych). Dookoła systemu UPS i innych szaf jest dostępna dostateczna ilość wolnego miejsca. Okolice całego wyposażenia UPS są wyposażone w dostateczne oświetlenie. 118 Tak/Nie Czynność Tak/Nie Gniazdo zasilania 230 V (prąd przemienny) do celów serwisowych jest dostępne w odległości do 7,5 m od sprzętu UPS. Zdalny wyłącznik awaryjny (REPO) znajduje się w miejscu montażu, a jego okablowanie jest zakończone wewnątrz szafy UPS. Jeśli wykorzystywany jest wyłącznik EPO w konfiguracji NC, styki 1 i 2 EPO muszą zostać połączone łącznikiem. (OPCJA) Przekaźniki alarmowe i wyjścia sygnałowe zostały właściwie podłączone. (OPCJA) Zdalny odłącznik baterii znajduje się w miejscu montażu, a jego okablowanie jest zakończone wewnątrz szafy UPS i szafy baterii. (OPCJA) Akcesoria znajdują się w miejscach montażu, a ich okablowanie jest zakończone wewnątrz szafy UPS. Upoważniony technik serwisu firmy Eaton lub wykwalifikowany technik serwisowy z autoryzacją firmy Eaton przeprowadzili rozruch i kontrolę eksploatacji. Rozpakowanie i wyładunek jednostki UPS przedstawiają rysunki 9.1 - 9.8. Przed rozpoczęciem rozpakowania i rozładunku systemu UPS, należy sprawdzić wskaźniki TipNTell i DropNTell na powierzchni opakowania. Jeśli urządzenie zostało prawidłowo przetransportowane w pozycji pionowej, wskaźniki powinny pozostać nienaruszone. Jeśli strzałka wskaźnika TipNTell zrobiła się cała niebieska lub grot(y) strzałki wskaźnika DropNTell są czarne, należy skontaktować się z odpowiednimi osobami, aby zgłosić nieprawidłowy transport. W celach związanych z transportem szafa UPS jest przymocowana śrubami do drewnianej palety. Przed rozładowaniem szafy z palety, należy użyć podnośnika widłowego lub innego urządzenia transportowego do przeniesienia urządzenia do miejsca montażu. OSTRZEŻENIE Szafa UPS jest ciężka. Nieprzestrzeganie instrukcji dotyczących rozpakowywania może być przyczyną przewrócenia szafy i poważnych obrażeń ciała. Nie wolno przechylać szaf UPS więcej niż 10 stopni od pionu. W przeciwnym razie może dojść do przewrócenia szafy. UWAGA: Po usunięciu wsporników transportowych, jednostkę należy natychmiast usunąć z palety. Po zdemontowaniu wsporników transportowych i wkręceniu nóżek poziomujących, do przenoszenia urządzenia nie należy używać podnośnika widłowego, gdy znajduje się nadal na palecie. Należy pamiętać, że szafa UPS jest ciężka i ma przymocowane kółka w dolnej części. W przypadku konieczności usunięcia szafy z pierwotnego miejsca instalacji i przeniesienia jej na palecie do nowego, należy obniżyć nóżki poziomujące do momentu aż szafa nie będzie opierać się na kółkach i zamontować wsporniki transportowe do szafy i palety. PL Do obowiązków operatora należy instalacja okablowania, które umożliwi podłączenie UPS do lokalnego źródła zasilania. Instalacja systemu UPS musi zostać wykonana przez wykwalifikowanego elektryka. Upoważniony technik serwisu firmy Eaton lub wykwalifikowany personel serwisowy z autoryzacją firmy Eaton może sprawdzić instalację, wykonać wstępny rozruch UPS lub zamontować dodatkową szafę baterii. 119 Montaż jednostki UPS przedstawiają rysunki 10.1-10.5. Zaciski kabla zasilającego UPS przedstawiają ilustracje 6.1 (rama 91PS 15 kW), 6.2 (rama 93PS 20 kW), 7.1 (rama 91PS 30 kW ze wspólną baterią), 7.2 (rama 91PS 30 kW z opcją osobnej baterii), 8.1 (rama 93PS 40 kW ze wspólną baterią) i 8.2 (rama 93PS 40 kW z opcją osobnej baterii). X1 X2 Wejście prostownika Wejście bypassu X4/TB20 X3 Wyjście UPS TB21 X4/+ UPM2 Zewnętrzna bateria + (osobna bateria) PE Zewnętrzna bateria Wyłącznik baterii zewnętrznej Wyłącznik baterii zewnętrznej Uziemienie ochronne Zaciski komunikacyjne UPS przedstawiają ilustracje 5.1 i 5.2. Zaciski mają oznaczenia, jak poniżej: 1. TB11, nieużywany 2. TB10, nieużywany 3. TB9, nieużywany 4. TB8, zewnętrzne przyłącze CAN 5. TB7, zewnętrzny CAN 6. TB6, magistrala komunikacji łańcuchowej 7. USB1, host USB (podłączenie akcesoriów) 8. USB2, urządzenie USB (połączenie z komputerem PC) 9. MiniSlot 1 10. TB1, wejście sygnałowe 1-5 11. TB2, nieużywany 12. TB3, nieużywany 13. Szeregowy port COM RS232 14. MiniSlot 2 15. TB4, EPO 16. TB5, wyjście przekaźnika W przypadku instalacji systemu baterii dostarczonego przez klienta należy zamontować system zgodnie z instrukcjami producenta baterii i systemu baterii oraz wszystkich stosownych krajowych przepisów i zarządzeń. W celu uzyskania danych technicznych baterii proszę odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. Jednostki UPS 91PS/93PS 8-40 kW zawsze są wyposażone w odłącznik wewnętrznej baterii, który dotyczy wyłącznie baterii wewnętrznych UPS (z wyjątkiem modeli C, w których odłącznik wewnętrznej baterii może zostać użyty dla baterii zewnętrznych). Kluczowym elementem zewnętrznej szafy lub regału baterii jest odłącznik baterii zewnętrznych. Urządzenia te muszą być w niego wyposażone. W przypadku odłącznika baterii zewnętrznej, znaczenie ma również okablowanie sygnałowe. Odłączniki baterii wewnętrznych i zewnętrznych mogą zostać wyzwolone (wyłączone) poprzez podłączenie napięcia do cewki wyzwalacza wzrostowego. Cewki wyzwalacza wzrostowego odłączników baterii zewnętrznych są podłączane do napięcia (sterowane) za pośrednictwem złączy TB20 i TB21 (złącze TB21 jest dostępne wyłącznie w przypadku systemu UPS o mocy 840 kW w konfiguracji z osobną baterią). Standardowe napięcie cewki wyzwalacza wzrostowego wynosi 24 V prądu stałego. PL Okablowanie wyłącznika samoczynnego baterii przedstawia rysunek 11. Części to: A 1 2 120 Odłącznik baterii zewnętrznej Styk 1, cewka wyzwalacza wzrostowego + Styk 2, cewka wyzwalacza wzrostowego - 3 4 Styk 3, styk AUX Styk 4, styk powrotny AUX Instrukcje na temat sposobu instalacji zewnętrznej szafy baterii i jej okablowania zasilającego znajdują się w instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton oraz instrukcji obsługi zewnętrznej szafy baterii. Zewnętrzną szafę baterii / system baterii dostarczany przez użytkownika należy uziemić za pomocą zacisku ochronnego PE 17. Wyłącznik EPO jest podłączony do górnego panelu przedniego systemu UPS za pośrednictwem złącza EPO. Złącza przełącznika EPO przedstawia rysunek 12. W celu uzyskania informacji dotyczących montażu złączy interfejsu proszę odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. Jeden styk przekaźnika ogólnego zastosowania należy do wyposażenia standardowego UPS. Jest także dostępny styk alarmu. Konfiguracje przekaźnika wyjściowego przedstawia rysunek 13. Można użyć styku normalnie otwartego lub normalnie zamkniętego. Jeśli stan styku zmieni się ze stanu określonego jako normalny, jest generowany sygnał. Można podłączyć ten styk do sprzętu w instalacji (jak np. oświetlenie czy dzwonek alarmowy), aby zasygnalizować stan alarmu UPS. UWAGA: Maksymalna obciążalność styków wynosi 30 V (prąd przemienny) (RMS) i 30 V (prąd stały) przy prądzie 5 A. W celu uzyskania informacji dotyczących okablowania równoległych systemów UPS 91PS/93PS proszę odnieść się do instrukcji obsługi i montażu systemu UPS 91PS/93PS 8-40 kW firmy Eaton. PL 121 1 PERICOLO Istruzioni importanti per la sicurezza! Conservare le presenti istruzioni! Il presente documento contiene importanti istruzioni sulla sicurezza e brevi istruzioni per l'ispezione dell'UPS alla consegna nonché per l'installazione dell'UPS. La presente guida rapida è destinata esclusivamente a essere usata come elenco di controllo per l'installazione in loco. Il presente documento è destinato a professionisti esperti che pianificano ed eseguono l’installazione dell’UPS. PERICOLO Prima di iniziare a lavorare sull’UPS, leggere le istruzioni di installazione complete fornite nel Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. Le istruzioni complete sono disponibili per il download dal sito www.eaton.com/91psand93ps. Le operazioni all’interno dell’UPS devono essere effettuate da un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e autorizzato da Eaton. All'interno dell'UPS non sono presenti parti sostituibili o riparabili dall'utente. L'unità UPS funziona con alimentazione da rete elettrica, batteria o alimentazione di bypass. Contiene componenti sottoposti a correnti e tensioni elevate. Per una corretta installazione dell'involucro, è necessaria una messa a terra adeguata e una classificazione IP20 contro scosse elettriche e corpi estranei. Nondimeno, l'unità UPS è un sistema di alimentazione sofisticato e solo il personale qualificato è autorizzato a effettuare l'installazione e gli interventi di manutenzione su di esso. PERICOLO In questo UPS sono presenti organi con tensioni letali. Le batterie costituiscono rischio di scosse elettriche o ustioni causate da elevata corrente di cortocircuito. Osservare le precauzioni. Le batterie potrebbero contenere TENSIONI ELEVATE e SOSTANZE CORROSIVE, TOSSICHE ed ESPLOSIVE. A causa della stringa della batteria, sulle prese di uscita può essere presente alta tensione anche quando l’alimentazione CA non è collegata all’UPS. Leggere le istruzioni per lo spegnimento nel Manuale utente e guida all'installazione. ATTENZIONE Questo UPS è alimentato dalla propria fonte di energia (batterie). I morsetti di uscita potrebbero essere sotto tensione anche quando l'UPS è disconnesso da una sorgente di CA. Per ridurre il rischio di incendi o scosse elettriche, installare l'UPS in un ambiente chiuso privo di elementi contaminanti conduttivi, con temperatura e umidità controllate. Non sovrapporre l’armadio modello C dell’UPS 91PS/93PS su altri armadi simili. Non sovrapporre niente sopra l’armadio dell’UPS 91PS/93PS. Se l’armadio modello C dell’UPS 91PS/93PS è installato su uno scaffale, usare i supporti necessari per evitare che l’UPS si ribalti o cada. IT 122 ATTENZIONE La temperatura ambiente non deve superare i 40 °C. Non utilizzare l'UPS in prossimità di acqua o eccessiva umidità (massimo 95%). Il sistema non è destinato all'uso in ambienti esterni. Prima di iniziare qualunque intervento di installazione o assistenza, verificare che tutte le fonti di alimentazione elettrica CA e CC siano disconnesse. L'alimentazione elettrica può provenire da diverse fonti. Verificare inoltre la continuità della connessione a terra / e dei conduttori PE. In un sistema parallelo, i morsetti di uscita potrebbero essere sotto tensione anche quando l'UPS è spento. Pericolo per presenza di energia elettrica. Per evitare lesioni, non tentare di alterare alcun cablaggio o connettore delle batterie. IMPORTANTE: Assicurarsi di disconnettere tutte le stringhe delle batterie prima dell'installazione. AVVISO Solo il personale addetto all'assistenza qualificato e competente in materia di batterie e precauzioni necessarie è autorizzato a effettuare interventi di installazione o assistenza sulle batterie. Gli interventi di installazione e manutenzione sulle batterie sono lavori su linee attive e richiedono l’uso di strumenti per interventi con tensione attiva. Tenere il personale non autorizzato lontano dalle batterie. Prima di installare o sostituire le batterie, considerare tutte le indicazioni di allarme e attenzione e le note relative alla corretta manipolazione. Non disconnettere le batterie con l'unità UPS in modalità batteria. Verificare che le batterie sostitutive siano dello stesso numero e tipo delle batterie installate in origine nell'UPS. Consultare le istruzioni più accurate presenti sull'UPS. Prima di connettere o disconnettere i terminali della batteria, scollegare la fonte di alimentazione di ricarica aprendo il corrispondente interruttore di circuito. Controllare che la batteria non sia stata inavvertitamente connessa a terra. Se lo è, rimuovere la sorgente di terra. Il contatto di una parte di una batteria con messa a terra può causare rischio di scosse elettriche. Smaltire le batterie in conformità alle disposizioni locali in materia di smaltimento dei rifiuti. Non smaltire le batterie nel fuoco. Se esposte al fuoco, le batterie possono esplodere. Per ridurre il rischio di incendio, collegare solo a un circuito dotato di interruttore di circuito con corrente nominale massima di ingresso in conformità ai regolamenti locali e nazionali per impianti elettrici. Per garantire un adeguato flusso d'aria di raffreddamento e proteggere il personale dalle tensioni elettriche pericolose presenti all'interno dell'unità, mantenere lo sportello dell'UPS chiuso e i pannelli anteriori installati. Non installare o utilizzare il sistema di UPS in prossimità di fonti di calore a gas o elettriche. Mantenere l'ambiente di lavoro entro i parametri stabiliti nel presente documento. Mantenere l'area circostante l'UPS ordinata, pulita e priva di umidità in eccesso. Osservare tutte le indicazioni di PERICOLO, AVVISO e ATTENZIONE apposte all'interno e all'esterno delle apparecchiature. 123 IT 2 Il gruppo di continuità (UPS, uninterruptible power supply) Eaton® 91PS/93PS è un sistema online monofase (91PS) o trifase (93PS), a stato solido, a doppia conversione, senza trasformatore, per servizio continuo. Fornisce alimentazione CA condizionata e continua ai carichi critici proteggendoli in caso di interruzioni di corrente. Le potenze nominali di uscita dell'unità Eaton 91PS/93PS si basano sui moduli di continuità di alimentazione (UPM) con potenza nominale di 15 kW o 20 kW. Il 91PS/93PS è disponibile anche come modello C costituito dalla parte elettrica del telaio da 15/20 kW dell’UPS 91PS/93PS senza vano batterie. Tabella 1. Valori nominali dell'armadio UPS Telaio UPS Immagine (Illustrazione 1) Numero di UPM Valori nominali 91PS 15 kW AeB 1 8, 10, 15 kW 91PS 30 kW C 1o2 8, 10, 15, 20, 30 kW 93PS 20 kW AeB 1 8, 10, 15 o 20 kW 93PS 40 kW C 1o2 8, 10, 15, 20, 30 o 40 kW I componenti principali dell’UPS 91PS/93PS da 8-40 kW sono mostrati nell’illustrazione 2. Le parti principali sono le seguenti: 1. 2. 3. 4. . Pannello di controllo Blocco sportello Modulo di alimentazione (UPM) Batteria interna (non nei modelli C) 5. 6. 7. 8. Area comunicazioni Interruttore di ingresso Interruttore di esclusione batteria Interruttore di bypass per manutenzione (opzionale) PERICOLO In questo UPS sono presenti organi con tensioni letali. Le operazioni all’interno dell’UPS devono essere effettuate da un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e autorizzato da Eaton. All'interno dell'UPS non sono presenti parti sostituibili o riparabili dall'utente. Per istruzioni complete sulla sicurezza, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. L’UPS deve essere installato in conformità alle raccomandazioni contenute nel Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. IT Utilizzare la seguente procedura di base per installare l'UPS: 124 1. 2. 3. 4. 5. 6. Creare un piano di installazione per il sistema UPS. Preparate il sito per il sistema UPS. Ispezione e disimballaggio degli armadi dell'UPS. Scaricare e installare l'armadio dell'UPS, quindi cablare il sistema. Completare l'elenco di controllo di installazione. Chiedere al personale di assistenza autorizzato di eseguire controlli operativi preliminari e avviare il sistema. NOTA: Le verifiche di avvio e in fase operativa devono essere eseguite esclusivamente da un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e autorizzato da Eaton, altrimenti la garanzia verrà invalidata. Prima di installare il sistema UPS, leggere e comprendere il modo in cui le presenti istruzioni possono essere applicate al sistema da installare. Seguire le procedure e le illustrazioni fornite per creare un piano logico per l'installazione del sistema. Per il funzionamento del sistema UPS alla massima efficienza, il luogo di installazione deve soddisfare i parametri ambientali indicati nel Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. L’ambiente di installazione deve soddisfare i requisiti di peso e dimensioni dell’UPS forniti nelle Tabelle 2 e 3. Le dimensioni dell’armadio dell’UPS sono indicate nell’illustrazione 1. Notare che la quota della profondità (750 mm) include i passacavi. Tabella 2. Peso dell'armadio dell'UPS con imballaggio in cartone Modello C 8-20 kW (Illustrazione 1, immagine A) Telaio da 15/20 kW* (Illustrazione 1, immagine B) Telaio da 30/40 kW* (Illustrazione 1, immagine C) Peso di spedizione 98 kg 293 kg 558 kg Peso dopo l'installazione 86 kg Carico sul pavimento 310 kg/m2 280 kg 1.107 kg/m2 532 kg 1.478 kg/m2 * Le batterie interne massime sono incluse in tutti i modelli. Gli armadi per UPS utilizzano il raffreddamento forzato dell'aria per regolare la temperatura dei componenti interni. Per impostazione predefinita, gli ingressi dell'aria si trovano sulla parte anteriore dell'armadio e le uscite sulla parte posteriore, vedere illustrazione 3. Lasciare uno spazio idoneo davanti e dietro a ciascun armadio per la corretta circolazione dell'aria. Verificare che l'aria di raffreddamento in ingresso nell'UPS non superi +40 °C. Per i requisiti di ventilazione, vedere il Manuale utente e guida all'installazione dell’UPS da 840 kW Eaton 91PS/93PS. 125 IT Tabella 3. Distanze minime dell'armadio UPS Telaio da 15/20 kW (Illustrazione 1, immagini A e B) Telaio da 30/40 kW (Illustrazione 1, immagine C) Dalla parte superiore dell'armadio 500 mm 500 mm Dalla parte anteriore dell'armadio 500 mm 650 mm Dalla parte posteriore dell'armadio 150 mm 250 mm 0 mm 0 mm Dalla parte laterale dell'armadio La temperatura ambiente e l’umidità raccomandate per il funzionamento del sistema UPS sono mostrate nelle illustrazioni 4.1 e 4.2. Si consiglia una temperatura ambiente compresa fra +20 °C e +25 °C per ottenere una lunga durata delle batterie VRLA. Tabella 4. Dimensioni minime raccomandate per cavo multiconduttore e fusibili per cavi di ingresso di bypass e raddrizzatore e cavi di uscita UPS (ingresso trifase, uscita trifase) Valori nominali dell’UPS 93PS (kW) 8 10 15 20 30 40 4*2,5 4*4 4*10 4*10 4*16 4*25 Fusibile del raddrizzatore [A] 20 20 32 40 63 80 Fusibile di bypass [A] 20 20 32 40 63 80 Cavo PE [mm2] 1*6 1*6 1*10 1*10 1*16 1*16 Cavo [mm2] Sezione massima del conduttore Telaio da 20 kW e modello C da 20 kW: cavo pieno da 16 mm2, cavo intrecciato con boccola: 10 mm2 Telaio da 40kW: cavo pieno da 70 mm2, cavo intrecciato con boccola: 50 mm2 Tabella 5. Dimensioni minime raccomandate per cavo multiconduttore e fusibili per cavi di ingresso di bypass e raddrizzatore e cavi di uscita UPS (ingresso trifase, uscita monofase) IT 126 Valori nominali dell’UPS 91PS (kW) 8 10 15 20 30 Cavo raddrizzatore [mm2]* 2,5 4 10 10 16 Fusibile del raddrizzatore [A] 20 20 32 40 63 Bypass, cavo di uscita [mm2] 10 16 25 35 70 Fusibile di bypass [A] 50 63 80 100 160 Cavo PE [mm2] 10 16 16 16 35 Valori nominali dell’UPS 91PS (kW) 8 10 15 20 30 Sezione massima conduttore, telaio 15 kW e modello 15 kW C Raddrizzatore: cavo pieno da 16 mm2, cavo intrecciato con boccola: 10 mm2 Bypass/uscita: cavo pieno da 70 mm2, cavo intrecciato con boccola: 50 mm2 Sezione massima del conduttore, telaio da 30 kW Raddrizzatore: cavo pieno da 70 mm2, cavo intrecciato con boccola: 50 mm2 Bypass/uscita: cavo pieno da 95 mm2, cavo intrecciato con boccola: 95 mm2 AVVISO Assicurarsi che la corrente di cortocircuito potenziale ai terminali di ingresso dell’UPS sia uguale o inferiore alla corrente di cortocircuito condizionale dichiarata sulla targhetta nominale dell’UPS. Tabella 6. Dimensioni minime raccomandate di cavi e fusibili per il banco esterno della batteria Valori nominali dell’UPS (kW) 8 10 15 20 30 40 Linea pos. e neg. [mm2] 1*16 1*16 1*16 1*16 1*35 1*35 63 63 63 63 160 160 1*16 1*16 1*16 1*16 1*16 1*16 Fusibile batteria [A] Cavo PE [mm2] Sezione massima del conduttore Telaio da 15/20 kW, modello C e telaio da 30/40 kW con batteria separata: cavo pieno: 25 mm2, cavo intrecciato con boccola: 16 mm2 Telaio da 30/40 kW con batteria comune: cavo pieno: 90 mm2, cavo intrecciato con boccola: 70 mm2 Per informazioni sulle correnti nominali e massime relative ai valori di potenza e tensione nominali, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. Per un’opzione batteria separata esterna, vi sono morsetti separati per entrambi i banchi della batteria (armadi), vedere la sezione 2.3.1. NOTA: La protezione contro la sovracorrente esterna non è fornita dal prodotto, ma è richiesta dalle normative. Per i requisiti di cablaggio, fare riferimento alle tabelle 4 e 5. Se è necessario un sezionatore bloccabile di uscita, deve essere fornito dall'utente. IT 127 Tabella 7. Coppie dei morsetti per i cavi di alimentazione dell'UPS Telaio UPS Funzione Coppia di serraggio Nm 93PS 20 kW X1, X2, X3: L1, L2, L3, N 1.6 X4: batteria +/PE (terra) 93PS 40 kW 3 10 Nm per cavo da 16-35 mm2 6 Nm per cavo da 4-10 mm2 4 Nm per cavo da 2,5 mm2 X1, X2, X3: L1, L2, L3, N 6 X4: batteria +/- 6 91PS 15 kW 91PS 30 kW PE (terra) 10 Nm per cavo da 16-35 mm2 6 Nm per cavo da 4-10 mm2 4 Nm per cavo da 2,5 mm2 X1 1.6 X2, X3 7 X4 3 PE (terra) 10 Nm per cavo da 16-35 mm2 6 Nm per cavo da 4-10 mm2 4 Nm per cavo da 2,5 mm2 X1 6 X2, X3 17 X4 6 PE (terra) 7 Nm (X1, X2, X3) 3.5 Nm (X4) Azione Tutti i materiali dell'imballaggio e i sostegni sono stati rimossi da ciascun armadio. Ciascun armadio del sistema UPS si trova nella posizione di installazione. Un kit di messa a terra dell'armadio / un kit di montaggio è installato fra gli armadi imbullonati fra loro. Tutti i condotti e i cavi sono stati disposti correttamente nell'UPS e negli armadi accessori. Tutti i cavi di alimentazione sono correttamente dimensionati e cablati. I conduttori neutri sono installati e collegati a massa in conformità ai requisiti. Il conduttore di massa è correttamente installato. I cavi della batteria sono terminati e connessi ai connettori della batteria. Il cablaggio del segnale di contatto Aux e di attivazione dello shunt della batteria è collegato dall'UPS all'interruttore della batteria. I punti di collegamento della LAN sono installati. IT Tutte le connessioni LAN sono completate. L'apparecchio di climatizzazione è installato e funziona correttamente. L'area attorno al sistema UPS installato è pulita e priva di polvere (si raccomanda di installare su una superficie piana adeguata per computer o apparecchiature elettroniche). 128 Sì/No Azione Sì/No È presente un adeguato spazio di lavoro tra l'UPS e altri armadi. È fornita un'illuminazione adeguata intorno a tutte le apparecchiature dell'UPS. Una presa di servizio a 230 VCA si trova entro 7,5 metri dalle apparecchiature dell'UPS. Il dispositivo REPO (Remote Emergency Power-off) è montato nella posizione di installazione e il relativo cablaggio è terminato all'interno dell'armadio dell'UPS. Se è utilizzato un dispositivo EPO nella configurazione NC, fra i pin 1 e 2 è installato un ponticello sull'EPO. (OPZIONALE) I relè di allarme e le uscite dei segnali sono collegate adeguatamente. (OPZIONALE) Un dispositivo di scollegamento remoto della batteria è montato nella posizione di installazione e il relativo cablaggio è terminato all'interno dell'armadio per UPS e batterie. (OPZIONALE) Gli accessori sono montati nelle posizioni di installazione e il cablaggio è terminato all'interno dell'armadio dell'UPS. I controlli per l'avvio e il funzionamento sono stati eseguiti da un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e autorizzato da Eaton. Le operazioni di disimballaggio e scarico dell'UPS sono mostrate nelle illustrazioni 9.1 9.8. Prima di iniziare a disimballare e scaricare l’UPS, controllare gli indicatori di danneggiamento TipNTell / DropNTell sulla superficie dell’imballaggio. Se l'apparecchiatura è stata trasportata correttamente in posizione verticale, gli indicatori devono essere intatti. Se la freccia dell’indicatore TipNTell è diventata interamente blu o le teste delle frecce per l’indicatore DropNTell sono nere, contattare le parti incaricate per segnalare un trasporto errato. L’armadio dell’UPS è imbullonato su un pallet di legno per il trasporto. Prima di scaricare l'armadio dal pallet, utilizzare un carrello elevatore a forca o altri dispositivi di movimentazione merci per spostare l'armadio nell'area di installazione. ATTENZIONE L'armadio dell'UPS è pesante. Se non si osservano rigorosamente le istruzioni per il disimballaggio, l'armadio potrebbe ribaltarsi e causare gravi lesioni. Non inclinare l'armadio dell'UPS di oltre 10° in verticale per evitare che si ribalti. NOTA: Dopo aver rimosso le staffe di trasporto, spostare immediatamente l'unità dal pallet. Dopo aver rimosso le staffe di trasporto e aver fatto ritrarre i piedini regolabili, non usare un carrello elevatore a forche per spostare l'unità quando è ancora sul pallet. Notare che l'armadio UPS è pesante ed è dotato di ruote orientabili nella parte inferiore. Se si rimuove l'armadio dalla posizione di installazione originale per trasferirlo in una nuova posizione utilizzando un pallet, far rientrare i piedini regolabili finché l'armadio non appoggia sulle ruote e collegare le staffe di trasporto all’armadio e al pallet. 129 IT L’operatore deve fornire il cablaggio per collegare l'UPS alla fonte di alimentazione locale. L’installazione dell’UPS deve essere effettuata da un elettricista del posto qualificato. L'ispezione dell'installazione e l'avvio iniziale dell'UPS, nonché l'installazione di un armadio della batteria supplementare devono essere eseguiti da un tecnico autorizzato dell'Assistenza clienti di Eaton o da personale addetto all'assistenza qualificato e autorizzato da Eaton. L’installazione dell'UPS è mostrata nelle illustrazioni 10.1-10.5. I terminali del cavo di alimentazione dell'UPS sono illustrati nella figura 6.1 (telaio da 15 kW 91PS), 6.2 (telaio da 20 kW 93PS), 7.1 (telaio da 30kW 91PS con batteria comune), 7.2 (telaio da 30kW 91PS con opzione batteria separata), 8.1 (telaio da 40kW 93PS con batteria comune) e 8.2 (telaio da 40kW 93PS con opzione batteria separata). X1 X2 X3 X4/+ UPM2 Ingresso raddrizzatore Ingresso bypass Uscita UPS Batteria esterna + (batteria separata) X4/TB20 TB21 PE Batteria esterna Esclusione batteria esterna Esclusione batteria esterna Terra di protezione I terminali di comunicazione dell'UPS sono mostrati nelle illustrazioni 5.1 e 5.2. I terminali sono i seguenti: 1. 2. 3. 4. 5. 6. TB11, non utilizzato TB10, non utilizzato TB9, non utilizzato TB8, terminazione esterna CAN TB7, CAN esterna TB6, bus pull chain 7. USB1, host USB (connessione agli accessori) 8. USB2, dispositivo USB (connessione al computer) 9. Mini-Slot 1 10. TB1, ingresso segnale 1-5 11. TB2, non utilizzato 12. TB3, non utilizzato 13. Porta COM in serie RS232 14. Mini-Slot 2 15. TB4, EPO 16. TB5, uscita relè Se si installa un sistema di batterie fornito dal cliente, è necessario operare conformemente alle istruzioni del produttore della batteria e del sistema di batterie e a tutti i codici e le normative nazionali applicabili. Per le specifiche della batteria, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. Le unità dell’UPS 91PS/93PS 8-40 kW sono sempre dotate di un interruttore di esclusione batteria interno che ha effetto solo sulle batterie interne dell’UPS (tranne per i modelli C in cui l’interruttore di esclusione batteria interno può essere usato per le batterie esterne). L'interruttore esterno di esclusione delle batterie è una parte cruciale dell'armadio o del rack portabatterie esterno e deve essere incluso in tale componente. Con l’interruttore esterno di esclusione della batteria, il cablaggio del segnale è importante. Per far scattare (disattivare) gli interruttori di esclusione batteria interni ed esterni è possibile eccitare la bobina di attivazione shunt. Le bobine di attivazione shunt di interruttori di esclusione batteria esterni sono alimentate (controllate) attraverso connettori TB20 e TB21 (TB21 disponibile solo nell’UPS da 8-40 kW con configurazione della batteria separata). La tensione predefinita di innesco della bobina di attivazione shunt è 24 VCC. IT 130 Il cablaggio di esclusione batteria è mostrato nell’illustrazione 11. Le parti sono le seguenti: A 1 2 Interruttore di esclusione batteria esterno Pin 1, bobina di attivazione shunt + Pin 2, bobina di attivazione shunt - 3 Pin 3, contatto AUX 4 Pin 4, ritorno contatto AUX Per istruzioni su come installare l’armadio batteria esterno e il cablaggio di alimentazione della batteria, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS e il manuale di istruzioni fornito con l’armadio della batteria esterno. Collegare a terra l’armadio batteria esterno / sistema di batterie fornito dal cliente al morsetto PE 17. L'interruttore EPO è connesso al connettore dedicato EPO posto sul pannello frontale superiore dell'UPS. Le connessioni dell’interruttore EPO sono mostrate nell’illustrazione 12. Per informazioni sulle connessioni dell’interfaccia di installazione, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. Un contatto relè per uso generico è fornito sull'UPS come caratteristica standard. È disponibile anche un contatto di allarme. Le configurazioni del relè di uscita sono mostrate nell’illustrazione 13. È possibile utilizzare un contatto normalmente chiuso o normalmente aperto. Se lo stato del segnale cambia dallo stato specificato come normale, viene emesso un segnale. Questo contatto può essere collegato all'apparecchiatura della struttura (ad esempio una spia o un allarme) per sapere quando sull'UPS si attiva un allarme. NOTA: I contatti azionati non devono superare 30 VCA (RMS) e 30 VCC a massimo 5 A. Per informazioni sul cablaggio dei sistemi UPS 91PS/93PS paralleli, vedere il Manuale utente e guida all'installazione dell’UPS da 8-40 kW Eaton 91PS/93PS. IT 131 132 133 134 135 Copyright © 2018 Eaton Corporation plc. All rights reserved. Unauthorized copying and lending are prohibited. Software Thank you for choosing an Eaton UPS. Enhance your purchase by downloading Eaton power management software Obrigado por escolher uma UPS Eaton. Incremente a sua compra ao fazer o download do software de gestão de energia da Eaton Gracias por elegir un UPS de Eaton. Descarga el software de administración de energía Eaton para mejorar su compra inmediatamente Eaton.com/downloads Vielen Dank, dass Sie sich für eine Eaton USV entschieden haben. Um das volle Potential zu nutzen, laden Sie die Eaton Power Management Software herunter Merci d’avoir choisi un onduleur Eaton. Bénéficiez de toutes ses performances en téléchargeant le logiciel de gestion d’énergie Eaton © 2015 Eaton. All rights reserved. Literature code: IL152001EN November 2015 Part Number: P-164000532 Rev 001 P-164000532_artwork.ai Eaton Power Quality Oy Koskelontie 13 FI-02920 Espoo ARTWORK, SOFTWARE DOWNLOAD INSERT Finland M. Carnes 11-DEC-2015 www.eaton.eu Release ECO-094337 P-164000532 11/3/15 2:05 PM 001 1 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138

Eaton 93PS Safety And Installation Quick Manual

Tipo
Safety And Installation Quick Manual
Este manual también es adecuado para

en otros idiomas