Manual del Operador 33
CALCOMANIAS DE SEGURIDAD Y UBICACION
NO RETIRE LAS CALCOMANIAS DE SEGURIDAD DE LA UNIDAD A MENOS QUE LAS REEMPLACE POR LAS
CALCOMANIAS DE SEGURIDAD MAS RECIENTES!
RISK OF ELECTROCUTION. DO NOT REMOVE THIS
LABEL.
1. Connect only to a properly grounded outlet. Do not remove ground pin.
2. Inspect cord before using. Do not use if cord is damaged.
3. Keep all connections dry and off the ground.
4. Do not touch plug with wet hands.
5. This unit may be provided with a Ground Fault Circuit Interrupter (GFCI)
built into the power cord plug. If replacement of plug or cord is needed, use
only identical replacement parts. If this unit is not provided with a GFCI, this
unit should only be connected to a power supply receptacle protected by a
ground fault circuit interrupter.
6. Do not use an extension cord with this machine.
7. Read the operator's manual carefully before using.
8. RISK OF INJECTION OR SEVERE INJURY TO
PERSONS:Keep clear of nozzle. Do not touch or direct discharge
stream at persons. This machine is to only be used by qualified operators.
9. RISK OF ELECTROCUTION: Do not direct spray toward any
electrical connections or outlets.
10. RISK OF EXPLOSION: Do not spray flammable liquids. Do not spray
in an area containing combustible dust, liquids or vapors.
11. RISK OF INJURY: Always wear proper safety attire including eye
protection. Do not use this product when children are present.
12. RISK OF CHEMICAL EXPOSURE: Use only water and
recommended detergents with this unit.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS
COULD RESULT IN A SEVERE ELECTRICAL SHOCK.
RIESGO DE ELCTROCUCION. NO QUITE ESTA
ETIQUETA.
1. Conecte solamente a una toma corriente que está bien fundado. No quite la
pata de conexión de la tierra.
2. Antes de usar inspeccióne la cuerda. No use si la cuerda està dañando.
3. Mantenga los conexiones secos y apar tados de la tierra.
4. No torque el enchufe con manos mojados.
5. Este producto debe conectarse a tierra. Asegúrese de que la lavadora a
presión esté equipada con un Interruptor de circuito de falla a tierra
(Ground Fault Circuit Interrupter, GCIF) incorporado en el cordón de
alimentación. Si no lo tiene, debe conectarse la lavadora a presión
únicamente en un receptáculo que esté protegido por un Interruptor de
circuito de falla a tierra. Desconéctela cuando no esté en uso.
6. No use una cuerda extensión con la unidad.
7. Antes de usar lea y entienda todas las instrucciónes y el manual de
operación.
8. RIESGO DE INYECCIÓN O LESION SEVERA: Mantenga la
boquilla despe jada. No dirija el chorro hacía alguna persona o hacía usted.
9. RIESGO DE ELECTROCUCIÓN: No dirija el rociado hacía
conexiones o toma corrientes electricos.
10. RIESGO DE EXPLOSION: No dirija el chorro hacía conexiones
electricos. Tomas de corrientes o lineas de alimentacion de corriente.
11. RIESGO DE LESION: Mientras se opera esta unidad se recomiendan
antiparras y protección apropriada. No use esta unidad cerca de niños.
12. RIESGO DE EXPOSICIÓN QUÍMICA: Use usted solemente aqua
y detergente con esta unidad.
SI NO SIGA LAS INSTRUCCIÓNES HAY EL RIESGO DE
ELECTROCUCIÓN SEVERA.
CAUTION
WARNING ADVERTENCIA
PRECAUCION
1. TO REDUCE RISK OF INJURY: Read and understand the
operation manual and all instructions before using.
2. STAY ALERT: Hold onto gun/wand firmly with both hands to avoid
dangerous kickbacks.
3. Do not overreach or stand on unstable support. Keep good footing and
balance at all times.
4. Inspect all hoses for kinking, cuts and leaks.
5. RISK OF EYE INJURY: Always wear eye protection.
6. Protect pump from freezing.
7. Always turn on water supply to pump before starting.
8. Engage trigger safety lock-off when not in use.
CONNECT TO AN INDIVIDUAL BRANCH
CIRCUIT ONLY.
1. PARA REDUCIR EL RIESGO DE QUE OCURRAN LESIONS:
Lea y entienda el manual de operacion y todas las instrucciones ante de usar
el producto.
2. PERMANIZCA ALERTA: Sostenga la pistola varilla firmenmente con
ambas mano para evitar golpes de retroceso peligrosos.
3. No se extienda demasiado o se pare en un apoyo inestable. Mantenga una
buena posicion y balance todo el tiempo.
4. Inspeccione las mangueras por dobleces, cortes y pérdidas.
5. RIESGO DE QUE OCULAR LESIONS: Use siempre proteccion
ocular.
6. Proteja la bomba de la congelacion.
7. Antes de comenzar. Abra sienpre el suminstro de agua a la bomba.
8. Coloque el suguro del gatillo en la posicion apagado cuando no este usando
el producto.
CONECTE A UNA RAMA INTERRUPTOR
INDIVIDUAL SOLAMENTE.
IMPORTANT IMPORTANTE
1. For indoor and outdoor use.
2. Store indoors.
3. Avoid pump damage. Protect from freezing. Do not run for more than 3
minutes with spray gun not triggered.
4. If connected to a circuit protected by fuses, use time-delay fuses only.
5. Servicing is to be done with the unit disconnected from the supply circuit.
1. Para uso interior y exterior.
2. Almacene bajo techo.
3. Evite daños a la bomba. Protéjala contra la congelación. No haga funcionar
por más de 3 minutos sin accionar el gatillo de la pistola.
4. Si se conecta a un circuito protegido por fusibles, use fusibles con retardo
solamente.
5. Para hacer los servicios, necesita desconectar la unidad del circuito de
suministro.
OPERATION
1. Be sure that the correct electrical system (voltage, amperage) is
supplied for this unit.
2. Connect the inlet water supply to the unit. Turn on the water
supply. Trigger gun to prime pump and release air.
3. Point gun in a safe direction. Brace wand securely to avoid
recoil.
4. To start the unit, press the green "ON" button.
5. To stop the unit, press the red "OFF" button. Always turn off
water supply and trigger spray gun to release pressure.
6. Observe lubrication and maintenance recommendations as listed
in the operator's manual.
1. Sea usted seguro que la sistema electrica es corecta (voltaje,
amperaje) para esta unidad.
2. Conecte usted el suministro del agua a la unidad. Encienda el
suministro del agua. Haz la pistola para preparar la bomba y
despedir el aire.
3. Haz la pistola en una manera segura. Afirme la varita
seguramente para evitar el retroceso.
4. Para encender la unidad, pon el botón verde de "encendido".
5. Para apagar la unidad, pon el botón rojo de "apagado".
6. Lea usted las recomendaciones del lubricacíon y el
mantenimiento como se dice en el manual del propietario.
OPERACIÓN
34-1137/102912
ON
I
OFF
O
CAUTION
PRECAUCION
34-1254/080912
Hot discharge fluid. Do not
touch or direct discharge
stream at people.
Pump surface temperature
is same as inlet water
temperature.
190°F maximum water inlet
temperature.
Descarga de caliente.¡No
dirija el chorro de descarga
hacia personas. De
temperatura del superficie la
bomba como lo mismo
entrada de temperatura del
agua.
Entrada de temperatura del
agua la máximo 190°F.
WARNING ADVERTENCIA
RISK OF EXPLOSION: Do not
spray flammable liquids.
RISK OF ELECTROCUTION: Do
not spray electrical apparatus
and wiring.
RISK OF INJECTION OR
SEVERE CUTTING INJURY:
Keep clear of nozzle. Do not
direct discharge stream at persons.
RIESGO DE EXPLOSI
ÓN
: No
rocie liquidos inflamables.
RIESGO DE ELECTROCUCIÓN:
No rocíe el aparato y el cableado
eléctricos.
RIESGO DE INYECCI
ÓN O LESIÓN
DE CORTE
: Manténgase alejado de la
boquilla. No dirija la corriente de descarga
hacia las personas.
34-1017/080612
RISK OF INJECTION OR SEVERE INJURY
Never put your hand, fingers or body directly
over the spray nozzle.
34-1253/07272012
RIESGO DE INYECCIÓN O LESIÓN SEVERA
Nunca coloque la mano, los dedos o el cuerpo
directamente sobre la boquilla de rocío.
WARNING
ADVERTENCIA
34-1477/080612
WARNING/ADVERTENCIA
If connection is made to
a potable water system,
the system shall be
protected against backflow.
Si la conexión se hace a un
sistema de agua potable, el
sistema será protegido
contra la expulsión.
34-1068/080912
IMPORTANT/IMPORTANTE
Do not operate
without water.
Do not use
water that is
over 125°F.
No se opere sin agua.
No se use con agua
con temperaturas de
mas de 52 °C.