Kohler 4960-ET-47 Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

Installation
Guide
Urinal
M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page “Français-1”
Español, página “Español-1”
K-4960 K-4904
1007294-2-D
K-4960-ET Roughing-In Dimensions
Roughing-in dimensions are identical if using an optional 3
outlet spud.
The urinal complies with ADA requirements when the rim is
mounted no higher than 17 (43.2 cm) from the finished floor.
3"
(7.6 cm)
3/4" Spud
12" (30.5 cm)
18" (45.7 cm)
Wall
Hangers
2" NPS
Tap
21"
(53.3 cm)
24"
(61 cm)
K-4960-ET
1/4"
(6 mm)
2" NPS Tap
3"
(7.6 cm)
19"
(48.3 cm)
28"
(71.1 cm)
14-1/8"
(35.9 cm)
40-1/2"
(102.9 cm)
To Floor
6" (15.2 cm)
Outlet Detail
1007294-2-D 4 Kohler Co.
K-4960-ER Roughing-In Dimensions
Roughing-In remains the same when using the optional 3” outlet
spud.
3/4" Spud
12" (30.5 cm)
18" (45.7 cm)
Wall
Hangers
2" NPS
Tap
21"
(53.3 cm)
24"
(61 cm)
K-4960-ER
1/4"
(6 mm)
2" NPS Tap
3"
(7.6 cm)
19"
(48.3 cm)
28"
(71.1 cm)
14-1/8"
(35.9 cm)
40-1/2"
(102.9 cm)
To Floor
6" (15.2 cm)
Outlet Detail
20-3/8"
(51.8 cm)
Kohler Co. 5 1007294-2-D
K-4904-ET Roughing-In Dimensions
Roughing-in remains the same when using the optional 3 outlet
spud.
*The urinal complies with ADA requirements when the rim is
mounted no higher than 17 (43.2 cm) from the finished floor.
3"
(7.6 cm)
3/4" Spud
12" (30.5 cm)
18" (45.7 cm)
Wall
Hangers
2" NPS
Tap
21"
(53.3 cm)
24"
(61 cm)
K-4904-ET
1/4"
(6 mm)
2" NPS Tap
3"
(7.6 cm)
19"
(48.3 cm)
26-7/8"
(68.3 cm)
14-1/8"
(35.9 cm)
40-1/2"
(102.9 cm)
To Floor
6" (15.2 cm)
Outlet Detail
1007294-2-D 6 Kohler Co.
K-4904-ER Roughing-In Dimensions
Roughing-in remains the same when using the optional 3 outlet
spud.
1. Preparation
NOTE: If a pre-existing waste pipe will be used and will result in an
acceptable rim height (refer to the rough-in dimensions), follow the
retrofit installation instructions.
Turn the water supply off.
Install or relocate the waste pipe as necessary to conform to the
roughing-in dimensions.
Install the shut-off valve.
Install adequate support framing for the wall hangers as needed.
12" (30.5 cm)
18" (45.7 cm)
Wall
Hangers
2" NPT
Tap
21"
(53.3 cm)
24"
(61 cm)
K-4904-ER
1/4"
(6 mm)
2" NPT Tap
3"
(7.6 cm)
19"
(48.3 cm)
26-7/8"
(68.3 cm)
20-3/4"
(52.7 cm)
40-1/2"
(102.9 cm)
To Floor
6" (15.2 cm)
Outlet Detail
14-1/8"
(35.9 cm)
3/4" Spud
Kohler Co. 7 1007294-2-D
K-4960-ET Dimensions de raccordement
Les dimensions de raccordement sont identiques lors de
l’utilisation du raccord de sortie optionnel de 3.
*L’urinoir est conforme aux exigences de l’ADA lorsque le rebord
n’est pas monté à plus de 17 (43,2 cm) du sol fini.
3"
(7,6 cm)
3/4" raccord
12" (30,5 cm)
18" (45,7 cm)
Supports
muraux
2" NPS
taraudé
21"
(53,3 cm)
24"
(61 cm)
K-4960-ET
1/4"
(6 mm)
2" NPS taraudé
3"
(7,6 cm)
19"
(48,3 cm)
28"
(71,1 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Au sol
6" (15,2 cm)
Détail sortie
Kohler Co. Français-3 1007294-2-D
K-4960-ER Dimensions de raccordement
Le raccordement demeure le même lors de l’utilisation du raccord
optionnel de sortie de 3.
3/4" raccord
12" (30,5 cm)
18" (45,7 cm)
Supports
muraux
2" NPS
taraudé
21"
(53,3 cm)
24"
(61 cm)
K-4960-ER
1/4"
(6 mm)
2" NPS taraudé
3"
(7,6 cm)
19"
(48,3 cm)
28"
(71,1 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Au sol
6" (15,2 cm)
Détail sortie
20-3/8"
(51,8 cm)
1007294-2-D Français-4 Kohler Co.
K-4904-ET Dimensions de raccordement
Le raccordement demeure le même lors de l’utilisation du raccord
de sortie optionnel de 3.
* L’urinoir est conforme aux exigences de l’ADA lorsque le rebord
n’est pas monté à plus de 17 (43,2 cm) du sol fini.
3"
(7,6 cm)
3/4" raccord
12" (30,5 cm)
18" (45,7 cm)
Supports
muraux
2" NPS
taraudé
21"
(53,3 cm)
24"
(61 cm)
K-4904-ET
1/4"
(6 mm)
2" NPS taraudé
3"
(7,6 cm)
19"
(48,3 cm)
26-7/8"
(68,3 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Au sol
6" (15,2 cm)
Détail sortie
Kohler Co. Français-5 1007294-2-D
Terminer l’installation (cont.)
Actionner la chasse et vérifier s’il y a des fuites.
1007294-2-D Français-8 Kohler Co.
Guía de instalación
Urinario
Herramientas y materiales
Gracias por elegir los productos Kohler
Gracias for elegir los productos de Kohler Co. Su producto de Kohler
Co. refleja la verdadera pasión por el diseño, la mano de obra, la
artesanía y la innovación que forman parte de Kohler Co. Estamos
seguros que su confiabilidad y belleza excederán sus más altas
expectativas, dándole satisfacción por años.
Toda la información que aparece en la guía está basada en la
información más reciente disponible al momento de publicación. En
Kohler Co. os esforzamos por alcanzar nuestra misión de mejorar el
nivel del buen vivir de quienes disfrutan de nuestros productos y
servicios. Nos reservamos el derecho de efectuar cambios en las
características, embalaje o disponibilidad del producto en cualquier
momento, sin previo aviso.
Dedique unos minutos para leer esta guía. Si tiene algún problema de
instalación o funcionamiento, llámenos al 1-800-4-KOHLER
(1-800-456-4537) desde los EE.UU. y Canadá, ó 001-800-456-4537 desde
México.
Llave de
trinquette de 1/4"
Lápiz
Cinta para
medir
Niveles
Destornillador
plano
Llave
ajustable
Cinta selladora
de roscas
Lentes de
seguridad
• Herramientas para perforar
orificios
Más:
Kohler Co. Español-1 1007294-2-D
Antes de comenzar
PRECAUCIÓN: Riesgo de lesiones personales o daños al producto.
Maneje este producto con cuidado. La porcelana vitrificada puede
romperse o despostillarse si no se maneja con cuidado.
NOTA: Las dimensiones de instalación no cambian si se utiliza el
spud de salida opcional de 3.
Cumpla con todos los códigos locales de plomería y construcción.
Consulte los códigos locales y las instrucciones del fabricante para
obtener los requisitos de la válvula de descarga.
Revise con cuidado el urinario nuevo para determinar si presenta
daños.
Las dimensiones del producto son nominales y cumplen con las
tolerancias establecidas por la norma A112.19.2 de ASME.
La preparación del sitio puede requerir herrajes y herramientas
adicionales.
Kohler Co. se reserva el derecho de modificar el diseño de los
productos sin previo aviso, tal como se especifica en la lista de
precios.
1007294-2-D Español-2 Kohler Co.
Dimensiones de instalación para K-4960-ET
Las dimensiones de instalación son idénticas si se utiliza un spud
de salida opcional de 3.
El urinario cumple con los requisitos de la ADA si la distancia
entre el borde y el piso acabado es menor de 17 (43,2 cm).
3"
(7,6 cm)
Spud de 3/4"
12" (30,5 cm)
18" (45,7 cm)
Soportes
de
suspensión
mural
Rosca de
2" NPS
21"
(53,3 cm)
24"
(61 cm)
K-4960-ET
1/4"
(6 mm)
Rosca de 2" NPS
3"
(7,6 cm)
19"
(48,3 cm)
28"
(71,1 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Al piso
6" (15,2 cm)
Detalle de la salida
Kohler Co. Español-3 1007294-2-D
Dimensiones de instalación para K-4960-ER
Las dimensiones de instalación no cambian si se utiliza el
opcional spud de salida de 3.
Spud de 3/4"
12" (30,5 cm)
18" (45,7 cm)
Soportes
de
suspensión
mural
Rosca de
2" NPS
21"
(53,3 cm)
24"
(61 cm)
K-4960-ER
1/4"
(6 mm)
Rosca de 2" NPS
3"
(7,6 cm)
19"
(48,3 cm)
28"
(71,1 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Al piso
6" (15,2 cm)
Detalle de la salida
20-3/8"
(51,8 cm)
1007294-2-D Español-4 Kohler Co.
Dimensiones de instalación para K-4904-ET
Las dimensiones de instalación no cambian si se utiliza el spud
de salida opcional de 3.
* El urinario cumple con los requisitos de la ADA si la distancia
entre el borde y el piso acabado no es mayor de 17 (43,2 cm).
3"
(7,6 cm)
Spud de 3/4"
12" (30,5 cm)
18" (45,7 cm)
Soportes
de
suspensión
mural
Rosca de
2" NPS
21"
(53,3 cm)
24"
(61 cm)
K-4904-ET
1/4"
(6 mm)
Rosca de 2" NPS
3"
(7,6 cm)
19"
(48,3 cm)
26-7/8"
(68,3 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Al piso
6" (15,2 cm)
Detalle de la salida
Kohler Co. Español-5 1007294-2-D
Dimensiones de instalación para K-4904-ER
Las dimensiones de instalación no cambian si se utiliza el spud
de salida opcional de 3.
1. Preparación
NOTA: Si va a utilizar la tubería de desagüe existente y el borde
tendrá una altura aceptable (consulte las dimensiones del diagrama
de instalación), siga las instrucciones de instalación de conversión.
Cierre el suministro de agua.
Instale o cambie el lugar de la tubería de desagüe según sea
necesario para cumplir con las dimensiones de la instalación.
Instale la llave de paso.
Instale la estructura de soporte adecuada para los soportes de
suspensión mural, según sea necesario.
12" (30,5 cm)
18" (45,7 cm)
Soportes
de
suspensión
mural
Rosca
NPT de
2"
21"
(53,3 cm)
24"
(61 cm)
K-4904-ER
1/4"
(6 mm)
Rosca NPT
de 2"
3"
(7,6 cm)
19"
(48,3 cm)
26-7/8"
(68,3 cm)
14-1/8"
(35,9 cm)
40-1/2"
(102,9 cm)
Al piso
6" (15,2 cm)
Detalle de la salida
20-3/4"
(52,7 cm)
Spud de 3/4"
1007294-2-D Español-6 Kohler Co.
2. Instale el urinario
PRECAUCIÓN: Riesgo de lesiones personales o daños al
producto. Maneje el producto con cuidado. La porcelana
vitrificada puede romperse o despostillarse si no se maneja
con cuidado.
PRECAUCIÓN: Riesgo de daños al producto. No apriete
demasiado los pernos.
Instale los soportes de suspensión mural según el diagrama de
instalación.
Aplique cinta selladora a las roscas de la tubería del desagüe e
instale el collarín en el desagüe.
Con la superficie cónica del empaque orientada al lado opuesto
del collarín, coloque el empaque con firmeza en el collarín.
Con cuidado, coloque el urinario sobre los soportes de suspensión
mural.
Fije el urinario al collarín utilizando los pernos y arandelas
provistos.
3. Termine la instalación
Instale la válvula de descarga según las instrucciones del
fabricante.
Conecte el suministro de agua y complete las conexiones de la
tubería de desagüe.
Soportes de suspensión mural instalados
Collarín
hembra
Arandela
Tornillo
Empaque
Aplique cinta
selladora.
Pared
Soportes de
suspensión mural
Kohler Co. Español-7 1007294-2-D
Termine la instalación (cont.)
Abra el suministro de agua.
Descargue el sistema y revise toda la instalación para verificar
que no haya fugas.
1007294-2-D Español-8 Kohler Co.
USA/Canada: 1-800-4KOHLER
México: 001-800-456-4537
kohler.com
©2009 Kohler Co.
1007294-2-D

Transcripción de documentos

Installation Guide Urinal K-4960 M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1” 1007294-2-D K-4904 3" (7.6 cm) 18" (45.7 cm) Wall 12" (30.5 cm) Hangers 3/4" Spud 14-1/8" (35.9 cm) 19" (48.3 cm) 2" NPS Tap 28" (71.1 cm) 40-1/2" (102.9 cm) To Floor 3" (7.6 cm) 21" (53.3 cm) 24" (61 cm) 2" NPS Tap 1/4" (6 mm) K-4960-ET 6" (15.2 cm) Outlet Detail K-4960-ET Roughing-In Dimensions • Roughing-in dimensions are identical if using an optional 3″ outlet spud. • The urinal complies with ADA requirements when the rim is mounted no higher than 17″ (43.2 cm) from the finished floor. 1007294-2-D 4 Kohler Co. 18" (45.7 cm) 3/4" Spud 14-1/8" (35.9 cm) 21" (53.3 cm) Wall Hangers 19" (48.3 cm) 20-3/8" (51.8 cm) 2" NPS Tap 12" (30.5 cm) 28" (71.1 cm) 40-1/2" (102.9 cm) To Floor 3" (7.6 cm) 24" (61 cm) 2" NPS Tap 1/4" (6 mm) 6" (15.2 cm) Outlet Detail K-4960-ER K-4960-ER Roughing-In Dimensions • Roughing-In remains the same when using the optional 3” outlet spud. Kohler Co. 5 1007294-2-D 3" (7.6 cm) 18" (45.7 cm) Wall 12" (30.5 cm) Hangers 3/4" Spud 14-1/8" (35.9 cm) 19" (48.3 cm) 2" NPS Tap 26-7/8" (68.3 cm) 40-1/2" (102.9 cm) To Floor 3" (7.6 cm) 21" (53.3 cm) 24" (61 cm) 2" NPS Tap 1/4" (6 mm) K-4904-ET 6" (15.2 cm) Outlet Detail K-4904-ET Roughing-In Dimensions • Roughing-in remains the same when using the optional 3″ outlet spud. • *The urinal complies with ADA requirements when the rim is mounted no higher than 17″ (43.2 cm) from the finished floor. 1007294-2-D 6 Kohler Co. 3/4" Spud 18" (45.7 cm) Wall 12" (30.5 cm) Hangers 14-1/8" (35.9 cm) 19" (48.3 cm) 20-3/4" (52.7 cm) 26-7/8" (68.3 cm) 40-1/2" (102.9 cm) To Floor 3" (7.6 cm) 2" NPT Tap 21" (53.3 cm) 24" (61 cm) 2" NPT Tap 1/4" (6 mm) K-4904-ER 6" (15.2 cm) Outlet Detail K-4904-ER Roughing-In Dimensions • Roughing-in remains the same when using the optional 3″ outlet spud. 1. Preparation NOTE: If a pre-existing waste pipe will be used and will result in an acceptable rim height (refer to the rough-in dimensions), follow the retrofit installation instructions. Turn the water supply off. Install or relocate the waste pipe as necessary to conform to the roughing-in dimensions. Install the shut-off valve. Install adequate support framing for the wall hangers as needed. Kohler Co. 7 1007294-2-D 3" (7,6 cm) 18" (45,7 cm) Supports 12" (30,5 cm) muraux 3/4" raccord 14-1/8" (35,9 cm) 19" (48,3 cm) 2" NPS taraudé 28" (71,1 cm) 40-1/2" (102,9 cm) Au sol 3" (7,6 cm) 21" (53,3 cm) 24" (61 cm) 2" NPS taraudé 1/4" (6 mm) K-4960-ET 6" (15,2 cm) Détail sortie K-4960-ET Dimensions de raccordement • Les dimensions de raccordement sont identiques lors de l’utilisation du raccord de sortie optionnel de 3″. • *L’urinoir est conforme aux exigences de l’ADA lorsque le rebord n’est pas monté à plus de 17″ (43,2 cm) du sol fini. Kohler Co. Français-3 1007294-2-D 18" (45,7 cm) 3/4" raccord 14-1/8" (35,9 cm) 21" (53,3 cm) Supports muraux 19" (48,3 cm) 20-3/8" (51,8 cm) 2" NPS taraudé 12" (30,5 cm) 28" (71,1 cm) 40-1/2" (102,9 cm) Au sol 3" (7,6 cm) 24" (61 cm) 2" NPS taraudé 1/4" (6 mm) 6" (15,2 cm) Détail sortie K-4960-ER K-4960-ER Dimensions de raccordement • Le raccordement demeure le même lors de l’utilisation du raccord optionnel de sortie de 3″. 1007294-2-D Français-4 Kohler Co. 3" (7,6 cm) 18" (45,7 cm) Supports 12" (30,5 cm) muraux 3/4" raccord 14-1/8" (35,9 cm) 19" (48,3 cm) 2" NPS taraudé 26-7/8" (68,3 cm) 40-1/2" (102,9 cm) Au sol 3" (7,6 cm) 21" (53,3 cm) 24" (61 cm) 2" NPS taraudé 1/4" (6 mm) K-4904-ET 6" (15,2 cm) Détail sortie K-4904-ET Dimensions de raccordement • Le raccordement demeure le même lors de l’utilisation du raccord de sortie optionnel de 3″. • * L’urinoir est conforme aux exigences de l’ADA lorsque le rebord n’est pas monté à plus de 17″ (43,2 cm) du sol fini. Kohler Co. Français-5 1007294-2-D Terminer l’installation (cont.) Actionner la chasse et vérifier s’il y a des fuites. 1007294-2-D Français-8 Kohler Co. Guía de instalación Urinario Herramientas y materiales Lentes de seguridad Cinta para medir Destornillador plano Llave ajustable Lápiz Más: • Herramientas para perforar orificios Niveles Cinta selladora Llave de de roscas trinquette de 1/4" Gracias por elegir los productos Kohler Gracias for elegir los productos de Kohler Co. Su producto de Kohler Co. refleja la verdadera pasión por el diseño, la mano de obra, la artesanía y la innovación que forman parte de Kohler Co. Estamos seguros que su confiabilidad y belleza excederán sus más altas expectativas, dándole satisfacción por años. Toda la información que aparece en la guía está basada en la información más reciente disponible al momento de publicación. En Kohler Co. os esforzamos por alcanzar nuestra misión de mejorar el nivel del buen vivir de quienes disfrutan de nuestros productos y servicios. Nos reservamos el derecho de efectuar cambios en las características, embalaje o disponibilidad del producto en cualquier momento, sin previo aviso. Dedique unos minutos para leer esta guía. Si tiene algún problema de instalación o funcionamiento, llámenos al 1-800-4-KOHLER (1-800-456-4537) desde los EE.UU. y Canadá, ó 001-800-456-4537 desde México. Kohler Co. Español-1 1007294-2-D Antes de comenzar PRECAUCIÓN: Riesgo de lesiones personales o daños al producto. Maneje este producto con cuidado. La porcelana vitrificada puede romperse o despostillarse si no se maneja con cuidado. NOTA: Las dimensiones de instalación no cambian si se utiliza el spud de salida opcional de 3″. Cumpla con todos los códigos locales de plomería y construcción. Consulte los códigos locales y las instrucciones del fabricante para obtener los requisitos de la válvula de descarga. Revise con cuidado el urinario nuevo para determinar si presenta daños. Las dimensiones del producto son nominales y cumplen con las tolerancias establecidas por la norma A112.19.2 de ASME. La preparación del sitio puede requerir herrajes y herramientas adicionales. Kohler Co. se reserva el derecho de modificar el diseño de los productos sin previo aviso, tal como se especifica en la lista de precios. 1007294-2-D Español-2 Kohler Co. 3" (7,6 cm) Soportes 18" (45,7 cm) de 12" (30,5 cm) suspensión mural Spud de 3/4" 14-1/8" (35,9 cm) 19" (48,3 cm) Rosca de 2" NPS 28" (71,1 cm) 40-1/2" (102,9 cm) Al piso 3" (7,6 cm) 21" (53,3 cm) 24" (61 cm) Rosca de 2" NPS 1/4" (6 mm) K-4960-ET 6" (15,2 cm) Detalle de la salida Dimensiones de instalación para K-4960-ET • Las dimensiones de instalación son idénticas si se utiliza un spud de salida opcional de 3″. • El urinario cumple con los requisitos de la ADA si la distancia entre el borde y el piso acabado es menor de 17″ (43,2 cm). Kohler Co. Español-3 1007294-2-D 18" (45,7 cm) Spud de 3/4" 14-1/8" (35,9 cm) 19" (48,3 cm) 20-3/8" (51,8 cm) Rosca de 2" NPS 21" (53,3 cm) 12" (30,5 cm) Soportes de suspensión mural 28" (71,1 cm) 40-1/2" (102,9 cm) Al piso 3" (7,6 cm) 24" (61 cm) Rosca de 2" NPS 1/4" (6 mm) 6" (15,2 cm) Detalle de la salida K-4960-ER Dimensiones de instalación para K-4960-ER • Las dimensiones de instalación no cambian si se utiliza el opcional spud de salida de 3″. 1007294-2-D Español-4 Kohler Co. 3" (7,6 cm) Soportes 18" (45,7 cm) de 12" (30,5 cm) suspensión mural Spud de 3/4" 14-1/8" (35,9 cm) 19" (48,3 cm) Rosca de 2" NPS 26-7/8" (68,3 cm) 40-1/2" (102,9 cm) Al piso 3" (7,6 cm) 21" (53,3 cm) 24" (61 cm) Rosca de 2" NPS 1/4" (6 mm) K-4904-ET 6" (15,2 cm) Detalle de la salida Dimensiones de instalación para K-4904-ET • Las dimensiones de instalación no cambian si se utiliza el spud de salida opcional de 3″. • * El urinario cumple con los requisitos de la ADA si la distancia entre el borde y el piso acabado no es mayor de 17″ (43,2 cm). Kohler Co. Español-5 1007294-2-D Spud de 3/4" Soportes 18" (45,7 cm) de 12" (30,5 cm) suspensión mural 14-1/8" (35,9 cm) 19" (48,3 cm) 20-3/4" (52,7 cm) 26-7/8" (68,3 cm) Rosca NPT de 2" 21" (53,3 cm) 40-1/2" (102,9 cm) Al piso 3" (7,6 cm) 24" (61 cm) Rosca NPT de 2" 1/4" (6 mm) K-4904-ER 6" (15,2 cm) Detalle de la salida Dimensiones de instalación para K-4904-ER • Las dimensiones de instalación no cambian si se utiliza el spud de salida opcional de 3″. 1. Preparación NOTA: Si va a utilizar la tubería de desagüe existente y el borde tendrá una altura aceptable (consulte las dimensiones del diagrama de instalación), siga las instrucciones de instalación de conversión. Cierre el suministro de agua. Instale o cambie el lugar de la tubería de desagüe según sea necesario para cumplir con las dimensiones de la instalación. Instale la llave de paso. Instale la estructura de soporte adecuada para los soportes de suspensión mural, según sea necesario. 1007294-2-D Español-6 Kohler Co. Soportes de suspensión mural instalados Aplique cinta selladora. Pared Collarín hembra Soportes de suspensión mural Arandela Tornillo Empaque 2. Instale el urinario PRECAUCIÓN: Riesgo de lesiones personales o daños al producto. Maneje el producto con cuidado. La porcelana vitrificada puede romperse o despostillarse si no se maneja con cuidado. PRECAUCIÓN: Riesgo de daños al producto. No apriete demasiado los pernos. Instale los soportes de suspensión mural según el diagrama de instalación. Aplique cinta selladora a las roscas de la tubería del desagüe e instale el collarín en el desagüe. Con la superficie cónica del empaque orientada al lado opuesto del collarín, coloque el empaque con firmeza en el collarín. Con cuidado, coloque el urinario sobre los soportes de suspensión mural. Fije el urinario al collarín utilizando los pernos y arandelas provistos. 3. Termine la instalación Instale la válvula de descarga según las instrucciones del fabricante. Conecte el suministro de agua y complete las conexiones de la tubería de desagüe. Kohler Co. Español-7 1007294-2-D Termine la instalación (cont.) Abra el suministro de agua. Descargue el sistema y revise toda la instalación para verificar que no haya fugas. 1007294-2-D Español-8 Kohler Co. USA/Canada: 1-800-4KOHLER México: 001-800-456-4537 kohler.com ©2009 Kohler Co. 1007294-2-D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Kohler 4960-ET-47 Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para