Operating Instructions
Electronic Display Counter
E5524E0402
1.1 Safety instructions and warnings
Only use this display
– according to its intended purpose
– if its technical condition is perfect
– adhering to the operating
instructions and the general
safety instructions.
1.2 General safety instructions
1. Before carrying out any installation or mainte-
nance work, make sure that the power supply
of the digital display is switched off.
2. Only use this digital display according to its
intended purpose:
If its technical condition is perfect.
Adhering to the operating instructions and the
general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in
areas with risks of explosion and in the
branches excluded by the standard EN 61010
Part 1.
5. The digital display shall only operated if it has
been correctly mounted in a panel, in accor-
dance with the chapter “Main technical fea-
tures”.
1.3 Use according to the intended
purpose
The digital display may only be used as a panel-
mounted device. Applications of this product may
be found in industrial processes and controls, in
manufacturing lines for the metal, wood, plastics,
paper, glass, textile and other processing
industries.
Over-voltages at the terminals of the digital dis-
play must be kept within the limits in Category II.
If the digital display is used to monitor machines
or processes in which, in case of a failure of the
device or an error made by the operator, there
might be risks of damaging the machine or caus-
ing accidents to the operators, it is your respon-
sibility to take appropriate safety measures.
1.4 Description
E5524E0402 is a multipurpose device.
Depending on the programmed basic function,
the device operates like
• an electronic totalizer and frequency meter
(see page 2)
• an electronic display counter with
2 totalizing ranges (see page 4)
• an electronic totalizer and time meter
(see page 6)
• an electronic time meter with 2 time ranges
(see page 9)
2. Setting of the operating pa ra me ters
a. Press both front side keys and switch on the
supply voltage or, if the supply voltage is
already on, press both keys simultaneously
for 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1.Hold the left key pressed and press the right
key to exit the programming operation.
c2.Press the right key to switch to
.
d. Hold the left key pressed and press the right
key to switch to the first parameter.
!
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 1
e. After releasing the keys, the display alternates
between the menu title and the current menu
item setting. After pressing any key, only the
menu item setting is displayed.
f. Pressing the right key will switch the menu
item setting to the next value.
If figures are to be input (e.g. when setting the
scaling factor), select first the decade using
the left key, and then set the value using the
right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title “EndPro” allows the user,
when selecting “Yes”, to exit the programming
menu and to store the new values.
If “no” is selected, the programming routine is
repeated, the latest values set remaining
active. They can now be checked again or
modified.
3. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
Electronic totalizer and frequency
meter
1. Description
6-digit totalizer
and frequency meter
Red LED display, character height 8 mm
[0.31 in.]
Display range 0 – 999 999
Lead zero blanking
Programming via two setting keys on the front
side
During programming, the display guides the
user with text prompts
Value conversion and display in 1/s or 1/min
2. Inputs
INP A
Dynamic count/frequency input.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Resets the counter to zero.
3. Selection of the displayed value
Pressing the right key allows switching between
the totalizer display and the frequency meter
display. Press the key briefly to display the cur-
rent function (“total” or “tacho”) for 2 seconds.
If, during this period of time, the right key is
pressed a second time, the device switches to
the next function and displays a confirmation
(“total” or “tacho”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
2 MN05401010E
Operating mode adding
counter and frequency
meter,
continued in point 4
below
Operating mode display
counter with 2 totalizing
ranges,
continued in point
4
on page 4
Operating mode totalizer
and time meter,
continued
in point 4
on page 7
Operating mode time
meter with 2 time ranges,
continued in point 4
on
page 9
- Subject to change without prior notice -
E5524E0402: basic operating mode
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 2
MN05401010E 3
english
4.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter (INP A)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.3 Multiplying factor (totalizer)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.4 Dividing factor ( totalizer)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
4.5 Decimal point (totalizer)
4.6 RESET mode (totalizer)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
4.7 Multiplying factor (frequency meter)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.8 Dividing factor (frequency meter)
The decimal point defines
the resolution in the select-
ed measuring range 1/min
or 1/sec
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
4.9 Decimal point (frequency meter)
The filter provides input
damping*
30 Hz filter off (f
max
)
30 Hz filter on
* where bounce occurs, e.g. with contacts
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 3
4 MN05401010E
4.12 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
4.10 Display mode (frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min
4.11 Max. time to wait until “0” is displayed
(frequency meter)
This parameter indicates, how long it takes,
when measuring is active, until “0” is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
Electronic display counter with
2 totalizing ranges
1. Description
6-digit display counter with Reset function
Red LED display, character height 8 mm
[0.31 in.]
Display range 0 – 999 999
Lead zero blanking
Programming via two setting keys on the front
side
During programming, the display guides the
user with text prompts
2. Inputs
INP A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can
be adjusted individually for Counter 1 and
Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of totalizer 1 and the display of
totalizer 2. Press the key briefly to display the
current function (“total1” or “total2”) for 2 sec-
onds. If, during this period of time, the right key
is pressed a second time, the device switches to
the next function and displays a confirmation
(“total1” or “total2”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
E5524E0402: basic operating mode
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 4
MN05401010E 5
english
4.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter (INP A)
30 Hz filter off (f
max
)
30 Hz filter on
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.3 Multiplying factor
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.4 Dividing factor
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
4.5 Decimal point
4.6 RESET mode (totalizer 1)
manual reset via the red
RESET key and
electrical reset via the
RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
4.7 RESET mode (totalizer 2)
manual reset via the red
RESET key and
electrical reset via the
RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
* where bounce occurs, e.g. with contacts
The filter provides input
damping*
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 5
6 MN05401010E
4.8 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
Electronic totalizer and time meter
1. Description
6 digit totalizer and time meter with Reset
function
Red LED display, character height 8 mm
[0.31 in.]
Display range 0 – 999 999
Lead zero blanking
Programming via two setting keys on the front
side
During programming, the display guides the
user with text prompts
Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
Time meter operating modes:
– Counting while INP B is inactive “GAtE.Lo”
– Counting while INP B is active “GAtE.hi”
– Count Start/Stop with INP B edge B
“Inb.Inb”
Counting ranges: h; min; s; h.min.s
2. Inputs
INP A
Dynamic count input for the totalizer.
INP B
Start-/Stop or gate input for time meter
(independent of the input mode)
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can
be adjusted individually for the totalizer and the
time meter.
3. Selection of the displayed value
Pressing the right key allows switching between
the totalizer display and the time meter display.
Press the key briefly to display the current func-
tion (“total” or “time”) for 2 seconds. If, during this
period of time, the right key is pressed a second
time, the device switches to the next function
and displays a confirmation (“total” or “time”) for
2 seconds. Then, the value of the selected func-
tion is displayed.
E5524E0402: basic operating mode
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 6
MN05401010E 7
english
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
4.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
max)
Count and start/stop inputs
not damped
30 Hz filter on
Count and start/stop inputs
damped
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.3 Multiplying factor (totalizer)
It can be set from 00.0001
up to 99.9999.
“0” is not accepted!
4.4 Dividing factor (totalizer)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
4.5 Decimal point (totalizer)
4.6 RESET mode (totalizer)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
Start/Stop via Inp B.
Timing while Inp B (Gate)
not active or open
Start/Stop via Inp B.
Timing while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Time
Start/Stop via
INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the timer
status.
4.7 Input mode (time meter)
* where bounce occurs, e.g. with contacts
The filter provides input
damping*
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 7
8 MN05401010E
Time unit: seconds (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: minutes (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: hours (resolu-
tion depending on posi-
tion of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
4.8 Operating mode (time meter)
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.9 Decimal point (time meter)
The decimal point defines
the resolution of the pro -
gram med time unit.
0 1
0.0 1/10 (0.1)
0.00 1/100 (0.01)
0.000 1/1000 (0.001)
4.11 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
4.10 RESET mode (time meter)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 8
MN05401010E 9
english
Electronic time meter with
2 time ranges
1. Description
6 digit time meter with Reset function
Red LED display, character height 8 mm
[0.31 in.]
Display range 0 – 999 999
Lead zero blanking
Programming via two setting keys on the front
side
During programming, the display guides the
user with text prompts
Operation indicator: the decimal point of the
lowest digit blinks while the count is active
Time meter operating modes:
– Timing while INP B is inactive “GAtE.Lo”
– Timing while INP B is active “GAtE.hi”
– Time Start/Stop with INP B edge (Inb.Inb)
– Time Start with INP A edge, time Stop with
INP B edge (InA.InB)
2. Inputs
INP A
Start input (depending on the input mode chosen)
INP B
Time meter Start/Stop or gate input (depending
on the input mode chosen)
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Resets the timer to zero. Can be
adjusted individually for Timer 1 and Timer 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of time meter 1 and the display of
time meter 2. Press the key briefly to display the
current function (“time1” or “time2”) for 2 sec-
onds. If, during this period of time, the right key
is pressed a second time, the device switches to
the next function and displays a confirmation
(“time1” or “time2”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
4.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
max)
Start/Stop inputs not
damped
30 Hz filter on
Start/Stop inputs damped
for use with me cha nical
switches
* where bounce occurs, e.g. with contacts
The filter provides input
damping*
E5524E0402: basic operating mode
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 9
10 MN05401010E
4.4 Operating mode
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.5 Decimal point
The decimal point defines
the resolution of the pro -
gram med time unit.
0 1
0.0 1/10 (0.1)
0.00 1/100 (0.01)
0.000 1/1000 (0.001)
4.7 RESET mode (time meter 2)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
only electrical reset via the
RESET input
only manual reset via the
red RESET key
4.6 RESET mode (time meter 1)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
Start/Stop via Inp B.
Timing while Inp B (Gate)
not active or open
Start/Stop via Inp B.
Timing while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Time
Start/Stop via
INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the timer
status.
Time start via INP A, stop
via INP B. (LOW-HIGH
edge with pnp; HIGH-
LOW edge with npn)
4.3 Input mode (time meter)
Time unit: seconds (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: minutes (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: hours (resolu-
tion depending on posi-
tion of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 10
MN05401010E 11
english
4.8 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
wil be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
5. Technical data
Supply voltage
Power supply: 10 – 30V DC/max. 40 mA
with inverse-polarity protection
Display: 6 digits, red 7 segment
LED display, height 8 mm
[0.31 in.]
Data retention: EEPROM
Polarity of the inputs:
Programmable, npn or pnp
(sinking or sourcing) for all
inputs
Input resistance:
appr. 5 kΩ
Count frequency:
1)
Start Gate.Lo Inp B not active
2)
Start InpB.InpB and Inp B connected with Inp A
* at maximum frequency square wave pulses 1:1
Frequency measurement:
Error: < 0.1 %
Measuring principle:
<
38 Hz: period measurement
> 38 Hz: gating time measurement
gating time = 26.3 ms
Time ranges:
Seconds 0.001 s – 999 999 s
Minutes 0.001min – 999 999 min
Hours 0.001 h – 999 999 h
h.min.s 00 h 00 min 01 s
– 99 h 59 min 59 s
Error <50 ppm
Minimum pulse length for the Reset input:
5 ms
Input sensitivity:
Standard sensitivity:
Low: 0 – 0.2 x U
B
[V DC]
High: 0.6 x U
B
– 30 [V DC]
U
B
= Supply Voltage
5V sensitivity: Low: 0 – 2V DC
High: 4 – 30V DC
Pulse shape: any,
Schmitt-Trigger inputs
Ambient temperature:
–20 ... +65°C at 10 ... 26 V DC
–20 ... +55°C at >26 ... 30 V DC
Storage temperature:
–25 to +70°C [-9 to 158°F]
EMC:
In compliance with the EC Directive
2004/108/EEC
Noise emission EN 61 000-6-3/
EN 55 011 Class B
Noise immunity EN 61 000-6-2
Housing:
For front panel mounting: 48 x 24 mm
[3.78 x 1.89 in.] acc. to DIN 43700, RAL7021,
dark grey
Weight: appr. 50 g [5.29 oz.]
Front panel rating: IP 65
Cleaning:
The front of the unit is to be cleaned only with a
soft cloth moistened with water.
DC power supply: 24V 12V 10 – 30V
Input level: Standard 5V
typ. low level: 2.5V 2.0V 1.0V
typ. high level: 22.0V 10V 4.0V
Fmax: kHz kHz kHz
tot.tac 35 20 8
tot.tot 60 20 8
tot.ti
1)
40 20 8
tot.ti
2)
15 10 8
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 11
12 MN05401010E
7. Contents:
1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.]
1 Bezel for clip mounting, panel cut out
50 x 25 mm [1.97 x 0.98 in.]
1 Seal
1 Multilingual operating instructions
6. Terminal assignment
8. Dimensions in mm [in.]:
1 10 – 30V DC
2 0 V GND
3 INP A
4 INP B
5 Reset
48 [1.89]
max. 19.3 [0.76]
22 x 5 [0.87 x 1.77]
24 [0.94]
59 [2.32]
4 [0.16]
6.5 [0.26]
Panel cut out:
22.2+0.3 x 45+0.6
[0.87+0.01 x 1.77+0.02]
53 [2.09]
50 + 0.6 [1.97 + 0.02]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
26 [1.10]
25 + 0.5
[0.98 + 0.02]
Front bezel Panel cut out:
40 [1.57]
56 [2.20]
25 [0.98]
25 x 50
[0.98 x 1.97]
50 [1.97]
M3
1 [0.04]
4 [0.16]
32 [ 1.26]
1
32 ± 0.01
[1.26 ± 0.004]
Counter sinking
Af3, DIN 74
1
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 12
MN05401010E 13
español
Instrucciones de puesta en servicio
Contador indicador electrónico
E5524E0402
1.1 Instrucciones de seguridad y
advertencias
Utilizar este visualizador únicamente
– de acuerdo con su función
material
– si se encuentra en perfecto
estado técnico
– respetando las instrucciones
deutilización y las instrucciones
generales de seguridad.
1.2 Instrucciones generales de
seguridad
1. Antes de todo trabajo de instalación o
mantenimiento, asegúrese de que la
alimentación del visualizador digital está
cortada.
2. Utilizar este visualizador únicamente de
acuerdo con su función material:
Si se encuentra en perfecto estado técnico.
Respetando las instrucciones de utilización y
las instrucciones generales de seguridad.
3. Cumplir las normativas correspondientes al
país y al usuario.
4. Este visualizador digital no debe utilizarse en
zonas que presenten riesgo de explosión y en
entornos de uso excluidos de la norma
EN 61 010 Parte 1.
5. Este aparato sólo debe funcionar encajado,
según la normativa profesiona, conforme a lo
indicado en el capítulo “Características
técnicas generales”.
1.3 Utilización correcta
Este visualizador digital sólo puede utilizarse
encajado. La aplicación de este producto
respecta a procesos industriales y de control, en
cadenas de fabricación de industrias del metal,
madera, materias plásticas, papel, vidrio,
textiles, etc. Las sobretensiones en los bornes
del aparato deben limitarse a los valores de la
categoría de sobretensión II.
Si se implanta el visualizador digital para la
vigilancia de máquinas o procesos en los que
puede aparecer un riesgo de daños a la
máquina o accidentes para los operarios en
caso de avería o de un error de manipulación
del aparato, usted tiene la obligación de adoptar
medidas de seguridad apropiadas.
1.4 Descripción
Las prestaciones del E5524E0402 hacen de él
un aparato universal. En función del modo de
funcionamiento seleccionado, se comporta como
• un totalizador y frecuencímetro electrónico
(véase página 14)
un contador indicador electrónico con
2 intervalos de totalización (véase página 16)
• un totalizador y contador de tiempo
electrónico (véase página 18)
• un contador de tiempo electrónico con 2
contadores de tiempo (véase página 21)
2. Ajuste de los parámetros de
funcionamiento
a. Pulsar las dos teclas de la cara delantera y
encender el aparato, o, con el aparato encen-
dido, pulsar las dos teclas durante 5 s.
b. En la pantalla aparece el mensaje
c. Cuando se dejan de pulsar las teclas, la pan-
talla indica .
c1. Mantener pulsada la tecla de la izquierda,
luego pulsar la tecla de la derecha para inter-
rumpir la operación de programación.
c2. Pulsar la tecla de la derecha para que la
pantalla indique .
d. Mantener pulsada la teclada de la izquierda,
luego pulsar la tecla de la derecha, para invo-
car el primer parámetro
!
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 13
e. Cuando se dejan de pulsar las teclas apare-
cen, en intervalos de un segundo, el título del
menú y el ajuste actual del punto del menú.
Pulsar una tecla: la pantalla deja de alternar y
sólo indica el ajuste del punto del menú.
f. Durante el ajuste, si se pulsa una vez la tecla
de la derecha se pasa al valor siguiente del
parámetro.
Para introducir valores numéricos (p. ej., al
ajustar el factor), seleccionar primero la déca-
da con la tecla de la izquierda, luego ajustar
su valor con la tecla de la derecha.
g. Para pasar al siguiente punto del menú, man-
tener pulsada la tecla de la izquierda y pulsar
la tecla de la derecha.
h. El último punto del menú, “EndPro”, permite,
si se selecciona “Yes”, salir del menú de pro-
gramación y asumir (almacenar en memoria)
los nuevos valores. Si se selecciona “no”, la
programación vuelve a comenzar después
del inicio, conservando los últimos valores
introducidos. En ese caso es posible compro-
barlos o modificarlos de nuevo.
3. Rutina de programación
El primer punto del menú es la selección del
modo de funcionamiento básico. Éste determina
las funciones del aparato.
Totalizador y frecuencímetro
electrónico
1. Descripción
Contador totalizador y frecuencímetro con 6
décadas
Pantalla de LED rojos, altura 8 mm
Intervalo de visualización 0 ... 999 999
Supresión de los ceros en cabeza
Programación con dos teclas de la cara
delantera
Programación guiada por mensajes en la pan-
talla
Conversión y visualización del valor en 1/s o
1/min
2. Entradas
INP A
Entrada de conteo/de frecuencia dinámica.
RESET
Entrada RESET dinámica conectada en paralelo
con la tecla RESET roja. Pone el contador a
cero.
3. Selección del valor visualizado
Pulsar la tecla de la derecha para cambiar entre
la pantalla del totalizador y la del frecuencímetro.
Si se pulsa una vez se visualiza durante 2 s la
función corriente (“total” o “tacho”). Si se pulsa la
tecla de la derecha de nuevo durante ese lapso
de tiempo, la pantalla pasa a la función actual, y
se visualiza (“total” o “tacho”) durante 2 s. para
confirmación. A continuación aparece el valor de
la función seleccionada.
4. Rutina de programación
Los parámetros ajustables del dispositivo se indi-
can abajo por su orden de aparición en la pan-
talla. Por tanto, el aparato está totalmente pro-
gramado después de un ciclo de programación.
Los primeros valores indicados corresponden al
ajuste de fábrica.
14 MN05401010E
Modo contador totalizador
y frecuencímetro, véase
pár. 4 en página 14
Modo contador indicador
con 2 intervalos de total-
ización, véase pár. 4 en
página 16
Modo contador totalizador
y contador de tiempo,
véase pár. 4 en página 19
Modo contador de tiempo
con 2 intervalos de tiempo,
véase pár. 4 en página 21
- Sin perjuicio de modificaciones técnicas -
E5524E0402: Modo de funcionamiento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 14
MN05401010E 15
español
4.1 Polaridad de las entradas
npn: conmutación a 0 V
pnp: conmutación a +U
B
4.2 Activación del filtro 30 Hz (INP A)
Filtro 30 Hz desactivado
(f
max
)
Filtro 30 Hz activado
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.3 Factor de multiplicación (totalizador)
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.4 Factor de división (totalizador)
El punto decimal determina
la representación del valor
de conteo. No tiene ningún
efecto sobre el conteo.
0 sin decimales
0.0 un decimal
0.00 dos decimales
0.000 tres decimales
4.5 Ajuste del punto decimal (totalizador)
4.6 Modo RESET (totalizador)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica sólo
por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
4.7 Factor de multiplicación (frecuencímetro)
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.8 Factor de división (frecuencímetro)
El punto decimal determina
la resolución.
0 sin decimales
0.0 un decimal
0.00 dos decimales
0.000 tres decimales
4.9 Ajuste del punto decimal (frecuencímetro)
El filtro amortigua la
entrada*
* en caso de rebotes; p. Ej. , con contactos
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 15
16 MN05401010E
4.12 Fin de la programación
La rutina de programación
se realiza otra vez. Los
valores introducidos
pueden comprobarse y
modificarse.
La rutina de programación
se termina y los valores
introducidos se tienen en
cuenta como nuevos
parámetros.
El dispositivo queda
entonces listo para fun-
cionar.
4.10 Modo de visualización (frecuencímetro)
Conversión y visualización
del valor en 1/s
Conversión y visualización
del valor en 1/min
4.11 Espera máxima (frecuencímetro)
Este valor indica cuánto tiempo debe esperar el
sistema a un impulso, cuando la medición está
en marcha, antes de representar 0 en pantalla.
Espera máxima 00.1 s
(valor mínimo)
Espera máxima 99,9 s
(valor máximo)
Contador indicador electrónico
con 2 intervalos de totalización
1. Descripción
Contador indicador con 6 décadas y función
Reset
Pantalla de LED rojos, altura 8 mm
Intervalo de visualización 0 ... 999 999
Supresión de los ceros en cabeza
Programación con dos teclas de la cara
delantera
Programación guiada por mensajes en la
pantalla
2. Entradas
INP A
Entrada de conteo dinámica Contador 1 y
Contador 2.
RESET
Entrada RESET dinámica conectada en paralelo
con la tecla RESET roja. Pone el contador a
cero. Ajustable de forma separada para el
Contador 1 y para el Contador 2.
3. Selección del valor visualizado
Pulsar la tecla de la derecha para cambiar entre
la pantalla del totalizador 1 y la del totalizador 2.
Si se pulsa una vez se visualiza durante 2 s la
función corriente (“total1” o “total2”). Si se pulsa
la tecla de la derecha de nuevo durante ese
lapso de tiempo, la pantalla pasa a la función
actual, y se visualiza (“total1” o “total2”) durante
2 s. para confirmación. A continuación aparece
el valor de la función seleccionada.
4. Rutina de programación
Los parámetros ajustables del dispositivo se indi-
can abajo por su orden de aparición en la pan-
talla. Por tanto, el aparato está totalmente pro-
gramado después de un ciclo de programación.
Los primeros valores indicados corresponden al
ajuste de fábrica.
E5524E0402: Modo de funcionamiento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 16
MN05401010E 17
español
4.1 Polaridad de las entradas
npn: conmutación a 0 V
pnp: conmutación a +U
B
4.2 Activación del filtro 30 Hz (INP A)
Filtro 30 Hz desactivado
(f
max
)
Filtro 30 Hz activado
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.3 Factor de multiplicación
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.4 Factor de división
El punto decimal determina
la representación del valor
de conteo. No tiene ningún
efecto sobre el conteo.
0 sin decimales
0.0 un decimal
0.00 dos decimales
0.000 tres decimales
4.5 Ajuste del punto decimal
4.6 Modo RESET (totalizador 1)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica
sólo por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
4.7 Modo RESET (totalizador 2)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica
sólo por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
El filtro amortigua la
entrada*
* en caso de rebotes; p. Ej. , con contactos
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 17
18 MN05401010E
4.8 Fin de la programación
La rutina de programación
se realiza otra vez. Los
valores introducidos
pueden comprobarse y
modificarse.
La rutina de programación
se termina y los valores
introducidos se tienen en
cuenta como nuevos
parámetros.
El dispositivo queda
entonces listo para
funcionar.
Totalizador y contador de tiempo
electrónico
1. Descripción
Totalizador y contador de tiempo
con 6 décadas y función Reset
Pantalla de LED rojos, altura 8 mm
Intervalo de visualización 0 ... 999 999
Supresión de los ceros en cabeza
Programación con dos teclas de la cara
delantera
Programación guiada por mensajes en la pan-
talla
Indicación de funcionamiento: el punto deci-
mal de la década más baja parpadea cuando
la medición del tiempo está activa
Modos de medición del tiempo:
Medición si INP B no está activado
“GAtE.Lo”
– Medición si INP B está activado “GAtE.hi”
– Inicio/parada de medición por el frente
INP B “Inb.Inb”
Intervalos de medición de tiempo: h; min; s;
h.min.s
2. Entradas
INP A
Entrada de conteo dinámica para el totalizador.
INP B
Entrada inicio/parada o entrada puerta para el
contador de tiempo (en función del tipo de entrada)
RESET
Entrada RESET dinámica conectada en paralelo
con la tecla RESET roja. Pone el contador a
cero. Ajustable de forma separada para el total-
izador y para el contador de tiempo.
3. Selección del valor visualizado
Pulsar la tecla de la derecha para cambiar entre
la pantalla del totalizador y la del contador de
tiempo. Si se pulsa una vez se visualiza durante
2 s la función corriente (“total” o “time”). Si se
pulsa la tecla de la derecha de nuevo durante
ese lapso de tiempo, la pantalla pasa a la fun-
ción actual, y se visualiza (“total” o “time”)
durante 2 s. para confirmación. A continuación
E5524E0402: Modo de funcionamiento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 18
MN05401010E 19
español
aparece el valor de la función seleccionada.
4. Rutina de programación
Los parámetros ajustables del dispositivo se indi-
can abajo por su orden de aparición en la pan-
talla. Por tanto, el aparato está totalmente pro-
gramado después de un ciclo de programación.
Los primeros valores indicados corresponden al
4.1 Polaridad de las entradas
npn: conmutación a 0 V
pnp: conmutación a +U
B
4.2 Activación del filtro 30 Hz (INP A, INP B)
Filtro 30 Hz desactivado (f
max)
Entradas de conteo y de inicio/
parada no amortiguadas
Filtro 30 Hz activado
Entradas de conteo y de
inicio/parada amortiguadas
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.3 Factor de multiplicación (totalizador)
Factor ajustable de
00.0001 a 99.9999.
El ajuste a “0” no se
acepta.
4.4 Factor de división (totalizador)
El punto decimal determina
la representación del valor
de conteo. No tiene ningún
efecto sobre el conteo.
0 sin decimales
0.0 un decimal
0.00 dos decimales
0.000 tres decimales
4.5 Ajuste del punto decimal (totalizador)
4.6 Modo RESET (totalizador)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica sólo
por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
Inicio/Parada por Inp B.
Medición si Inp B (puerta)
no está activo o está
abierto
Inicio/Parada por Inp B.
Medición si Inp B (puerta)
está activo (nivel alto para
pnp; nivel bajo para npn)
Medición puesta en marcha
y parada por INP B (frente
de impulso ascendente
para pnp; frente de impulso
descendente para npn).
Cada frente activo modifica
el estado de conteo.
4.7 Tipo de entrada (contador de tiempo)
El filtro amortigua la
entrada*
* en caso de rebotes; p. Ej. , con contactos
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 19
20 MN05401010E
Unidad de tiempo:
segundos (el ajuste del
punto decimal determina
la resolución*)
Unidad de tiempo:
minutos (el ajuste del
punto decimal determina
la resolución*)
Unidad de tiempo:
horas (el ajuste del punto
decimal determina la
resolución*)
Unidad de conteo:
Horas:Minutos:Segundos
(el ajuste del punto deci-
mal no se tiene en cuenta)
4.8 Modo de funcionamiento
(contador de tiempo)
*0, 0.1, 0.01, 0.001 significa: medición del tiempo
en 0, 0,1, 0,01, 0,001 unidades de tiempo
4.9 Ajuste del punto decimal
(contador de tiempo)
El punto decimal determina
la resolución de la unidad
de tiempo programada.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.11 Fin de la programación
La rutina de programación
se realiza otra vez. Los
valores introducidos
pueden comprobarse y
modificarse.
La rutina de programación
se termina y los valores
introducidos se tienen en
cuenta como nuevos
parámetros.
El dispositivo queda
entonces listo para
funcionar.
4.10 Modo RESET (contador de tiempo)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica sólo
por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 20
MN05401010E 21
español
Contador de tiempo electrónico
con 2 contadores
1. Descripción
Contador de tiempo con 6 décadas y función
Reset
Pantalla de LED rojos, altura 8 mm
Intervalo de visualización 0 ... 999 999
Supresión de los ceros en cabeza
Programación con dos teclas de la cara
delantera
Programación guiada por mensajes en la pantalla
Indicación de funcionamiento: el punto deci-
mal de la década más baja parpadea cuando
la medición del tiempo está activa
Modos de medición del tiempo:
Medición si INP B no está activado
“GAtE.Lo”
– Medición si INP B está activado “GAtE.hi”
– Inicio/parada de medición por el frente
INP B “Inb.Inb”
– Inicio de medición por el frente Inp A,
parada de medición por el frente INP B
(InA.InB)
Intervalos de medición de tiempo: h; min; s; h.min.s
2. Entradas
INP A
Entrada de inicio (en función del tipo de entrada)
INP B
Entrada inicio/parada o entrada puerta para el con-
tador de tiempo (en función del tipo de entrada)
RESET
Entrada RESET dinámica conectada en paralelo
con la tecla RESET roja. Pone el contador en
cero. Ajustable separadamente para el Contador
1 y para el Contador 2.
3. Selección del valor visualizado
Pulsar la tecla de la derecha para cambiar entre
la pantalla del contador de tiempo 1 y la del
contador de tiempo 2. Si se pulsa una vez se
visualiza durante 2 s la función corriente (“time1”
o “time2”). Si se pulsa la tecla de la derecha de
nuevo durante ese lapso de tiempo, la pantalla
pasa a la función actual, y se visualiza (“time1” o
“time2”) durante 2 s. para confirmación. A
continuación aparece el valor de la función
seleccionada.
4. Rutina de programación
Los parámetros ajustables del dispositivo se indi-
can abajo por su orden de aparición en la pan-
talla. Por tanto, el aparato está totalmente pro-
gramado después de un ciclo de programación.
Los primeros valores indicados corresponden al
ajuste de fábrica.
4.1 Polaridad de las entradas
npn: conmutación a 0 V
pnp: conmutación a +U
B
4.2 Activación del filtro 30 Hz (INP A, INP B)
Filtro 30 Hz desactivado
(f
max)
Entrada de inicio/parada
no amortiguada
Filtro 30 Hz activado
Amortiguación de las
entradas de inicio/parada
para un comando por
contactos mecánicos
El filtro amortigua la
entrada*
* en caso de rebotes; p. Ej. , con contactos
E5524E0402: Modo de funcionamiento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 21
22 MN05401010E
Unidad de tiempo: segundos
(el ajuste del punto decimal
determina la resolución*)
Unidad de tiempo: minutos
(el ajuste del punto decimal
determina la resolución*)
Unidad de tiempo: horas
(el ajuste del punto decimal
determina la resolución*)
Unidad de conteo:
Horas:Minutos:Segundos
(el ajuste del punto deci-
mal no se tiene en cuenta)
4.4 Modo de funcionamiento
*0, 0.1, 0.01, 0.001 significa: medición del tiempo
en 0, 0,1, 0,01, 0,001 unidades de tiempo
4.5 Ajuste del punto decimal
El punto decimal determina
la resolución de la unidad
de tiempo programada
.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 Modo RESET (contador de tiempo 2)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Puesta a cero eléctrica
sólo por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
Puesta a cero eléctrica sólo
por la entrada RESET
Puesta a cero manual sólo
por la tecla RESET roja
4.6 Modo RESET (contador de tiempo 1)
Puesta a cero manual con
la tecla RESET roja y eléc-
trica por la entrada RESET
No hay puesta a cero (tecla
RESET roja y entrada
RESET desactivadas)
Inicio/Parada por Inp B.
Medición si Inp B (puerta)
no está activo o está
abierto
Inicio/Parada por Inp B.
Medición si Inp B (puerta)
está activo (nivel alto para
pnp; nivel bajo para npn)
Medición puesta en mar-
cha y parada por INP B
(frente de impulso ascen-
dente para pnp; frente de
impulso descendente
para npn). Cada frente
activo modifica el estado
de conteo.
Medición puesta en mar-
cha por INP A, parada por
INP B. (frente de impulso
ascendente para pnp;
frente de impulso descen-
dente para npn)
4.3 Tipo de entrada (contador de tiempo)
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 22
MN05401010E 23
español
4.8 Fin de la programación
La rutina de programación
se realiza otra vez. Los val-
ores introducidos pueden
comprobarse y modificarse.
La rutina de programación
se termina y los valores
introducidos se tienen en
cuenta como nuevos
parámetros.
El dispositivo queda
entonces listo para
funcionar.
5. Características técnicas
Tensión de alimentación
Alimentación: 10 ... 30 V CC/max. 50 mA
con protección contra las
inversiones de la polaridad
Pantalla : Roja, 6 décadas, LED con
7 segmentos, altura 8 mm
Memorización de datos:
EEPROM
Polaridad de las entradas:
Programable, npn o pnp
para todas las entradas
Resistencia de entrada:
alrededor de 5 kΩ
Frecuencias de conteo:
* a máxima frecuencia impulsos de onda cuadrada 1:1
1)
Start Gate.Lo Inp B no está activo
2)
Start InpB.InpB e Inp B conectado con Inp A
Medición de la frecuencia:
Precisión: < 0,1 %
Principio de medida:
< 38 Hz: Medición de duración del
periodo
> 38 Hz: Medición de duración de
accionamiento de puerta
Medicióne de puerta 25,3 ms
Intervalos de medición de tiempo:
Segundos 0,001 s ... 999 999 s
Minutos 0,001min ... 999 999 min
Horas 0,001 h ... 999 999 h
h.min.s 00 h 00 min 01 s
... 99 h 59 min 59 s
Precisión <50 ppm
Duración mínima de impulso en la entrada de
puesta a cero: 5 ms
Nivel de conmutación de las entradas:
Nivel estándar:
Low: 0 ... 0,2 x U
B
[V CC]
High: 0,6 x U
B
... 30 [V CC]
U
B
= Suministro de voltaje
Nivel 5V: Low: 0 ... 1 V CC
High: 4 ...30 V CC
Forma de los impulsos*:
cualquiera, entrada por
disparador de Schmitt
Temperatura ambiente:
–20 ... +65 °C a 10 ... 26 V DC
–20 ... +55 °C a >26 ... 30 V DC
Temperatura de almacenamiento:
–25 ... +70 °C
CEM:
Conforme con la directiva CE 2004/108/CEE
Emisión de ruidos EN 61 000-6-3/
EN 55 011 Clase B
Inmunidad a las ruidos
EN 61 000-6-2
Caja:
Para montaje en panel: 48 x 24 mm
según DIN 43700, RAL7021, gris oscuro
Peso: alrededor de 50 g
Tipo de protección:IP 65 (cara delantera)
Limpieza:
Los frontales de los aparatos deben limpiarse
exclusivamente con un paño suave húmedo.
Alimentación CC: 24 V 12 V 10 ... 30 V
Nivel: Standard 5 V
typ. Low: 2,5 V 2,0 V 1,0 V
typ. High: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
tot.tac 35 20 8
tot.tot 60 20 8
tot.ti
1)
40 20 8
tot.ti
2)
15 10 8
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 23
24 MN05401010E
6. Conexiones 7. El suministro incluye:
1 Indicador
1 Brida de fijación
1 Marco para fijación por brida, para recorte en
panel 50 x 25 mm
1 Marco para fijación por tornillos, para recorte
en panel 50 x 25 mm
1 Junta de estanqueidad
1 Manual de instrucciones multilingüe
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 Reset
8. Dimensiones:
48 [1.89]
max. 19.3 [0.76]
22 x 5 [0.87 x 1.77]
24 [0.94]
59 [2.32]
4 [0.16]
6.5 [0.26]
53 [2.09]
50 + 0.6 [1.97 + 0.02]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
26 [1.10]
25 + 0.5
[0.98 + 0.02]
40 [1.57]
56 [2.20]
25 [0.98]
25 x 50
[0.98 x 1.97]
50 [1.97]
M3
1 [0.04]
4 [0.16]
32 [ 1.26]
1
32 ± 0.01
[1.26 ± 0.004]
Avellanado Af3, DIN 74
1
Bisel delantero Corte en el panel:
Corte en el panel:
22,2+0,3 x 45+0,6 mm
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 24
MN05401010E 25
français
Notice de mise en service
Compteur à affichage électronique
E5524E0402
1.1 Instructions de sécurité et
avertissements
N’utiliser ces afficheurs que
– de manière conforme à leur
destination
– s’ils sont techniquement en
parfait état
– en respectant les instructions
d’utilisation et les instructions
générales de sécurité.
1.2 Onstructions générales de sécurité
1. Avant tout travail d’installation ou de
maintenance, s’assurer que l’alimentation de
l’afficheur digital est coupée.
2. N’utiliser cet afficheur que de manière
conforme à sa destination:
Il doit être techniquement en parfait état.
Respecter les instructions d’utilisation et les
instructions générales de sécurité.
3. Tenir compte des réglementations spécifiques
au pays et à l’utilisateur.
4. L’afficheur digital ne convient pas pour des
zones présentant des risques d’explosion, ni
dans les domaines d’utilisation exclus par la
norme EN 61010 Partie 1.
5. L’afficheur digital ne doit être utilisé que s’il a
été encastré dans les règles de l’art,
conformément au chapitre “Caractéristiques
techniques générales”.
1.3 Utilisation conforme
L’afficheur digital ne peut être utilisé qu’en tant
qu’appareil encastré. Ce produit trouve son
application dans les process industriels et les
commandes, dans le domaine des chaînes de
fabrication des industries du métal, du bois, des
matières plastiques, du papier, du verre, du
textile, etc.
Les surtensions aux bornes de l’afficheur digital
doivent être limitées aux valeurs de la catégorie
de surtension II.
Si l’afficheur digital est mis en oeuvre pour la
surveillance de machines ou de process où, en
cas de panne ou d’une erreur de manipulation
de l’appareil, peuvent apparaître des risques de
dommages à la machine ou d’accidents pour les
opérateurs, il vous appartient de prendre les
mesures de sécurité appropriées.
1.4 Description
L’exécution du E5524E0402 en fait un appareil
universel. En fonction du mode de fonction-
nement sélectionné, il se comporte comme
un totalisateur et fréquencemètre
électronique (voir page 26)
un compteur à affichage électronique avec
2 plages de totalisation (voir page 28)
un totalisateur et compteur de temps
électronique (voir page 30)
un compteur de temps électronique avec 2
compteurs de temps (voir page 33)
2. Réglage des pa ra tres de
fonctionnement
a. Presser les deux touches de la face avant et
mettre l’appareil sous tension, ou, l’appareil
étant sous tension, presser les deux touches
pendant 5 s.
b. Sur l’affichage apparaît le message
c. Dès que les touches sont relâchées,
l’affichage indique
c1.Maintenir la touche de gauche pressée, puis
presser la touche de droite, pour interrompre
l’opération de programmation.
c2.Presser la touche de droite pour que
l’affichage indique
.
d. Maintenir la touche de gauche pressée, puis
presser la touche de droite, pour appeler le
premier paramètre.
!
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 25
e. Dès relâchement des touches apparaît, par
périodes d’une seconde, le titre du menu et sa
programmation actuelle. Presser une touche :
l’affichage cesse d’alterner et n’indique plus
que le réglage du point du menu.
f. Une impulsion sur la touche de droite permet
de passer à la valeur suivante du paramètre
en cours de réglage.
Pour introduire des valeurs numériques (p. ex.
lors du réglage du facteur), sélectionner
d’abord la décade à l’aide de la touche de
gauche, puis régler sa valeur à l’aide de la
touche de droite.
g. Pour passer au paramètre suivant du menu,
maintenir la touche de gauche pressée et
presser la touche de droite.
h. Le dernier paramètre du menu, “EndPro”, per-
met, en sélectionnant “Yes”, de quitter le
menu de programmation et de prendre en
compte (sauvegarder) les nouvelles valeurs.
Si “No” est sélectionné, la programmation
recommence depuis le début, en conservant
les dernières valeurs introduites. Il est alors
possible de les vérifier ou de les modifier à
nouveau.
3. Routine de programmation
Le premier point du menu est la sélection du
mode de fonctionnement de base. Celui-ci
détermine les fonctions de l’appareil.
Totalisateur et fréquencemètre
électronique
1. Description
Compteur totalisateur et fréquencemètre à 6
décades
Affichage par LED rouges, hauteur 8 mm
Plage d’affichage de 0 à 999 999
Suppression des zéros de tête
Programmation par deux touches sur la face
avant
Programmation guidée par des messages sur
l’affichage
Conversion et affichage de la valeur
en 1/s ou 1/min
2. Entrées
INP A
Entrée de comptage/de fréquence dynamique.
RESET
Entrée RESET dynamique couplée en parallèle
avec la touche RESET rouge. Remet le comp-
teur à zéro.
3. Sélection de la valeur affichée
Presser la touche de droite pour commuter entre
l’affichage du totalisateur et celui du
fréquencemètre. Une impulsion unique affiche
pendant 2 s. la fonction courante (“total” ou
“tacho”). Si la touche de droite est pressée à
nouveau pendant ce laps de temps, l’affichage
passe à la fonction courante, et (“total” ou
“tacho”) s’affiche pendant 2 s. pour confirmation.
Ensuite, la valeur de la fonction sélectionnée
s’affiche.
4. Routine de programmation
Les paramètres réglables de l’appareil sont
indiqués ci-dessous dans l’ordre de leur apparition
sur l’affichage. L’appareil est donc entièrement
programmé après un cycle de programmation.
Les premières valeurs indiquées correspondent
au réglage d’usine.
26 MN05401010E
Mode compteur totalisateur
et fréquencemètre,
voir par. 4 en page 26
Mode compteur à affichage
avec 2 plages de totalisa-
tion, voir par.
4 en page 28
Mode compteur totalisateur
et compteur de temps,
voir par. 4. en page 31
Mode compteur de temps
avec 2 plages de temps,
voir par. 4. en page 33
- Sous réserve de modifications techniques -
E5524E0402 : Mode de fonctionnement
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 26
MN05401010E 27
français
4.1 Polarité des entrées
npn : commutation à 0 V
pnp : commutation à +U
B
4.2 Activation du filtre 30 Hz (INP A)
Filtre 30 Hz désactivé
(f
max)
Filtre 30 Hz activé
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.3 Facteur de multiplication (totalisateur)
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.4 Facteur de division (totalisateur)
Le point décimal détermine
la représentation de la
valeur de comptage. Il n’a
aucun effet sur le
comptage.
0 pas de décimale
0.0 une décimale
0.00 deux décimales
0.000 trois décimales
4.5 Réglage du point décimal (totalisateur)
4.6 Mode RESET (totalisateur)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
4.7 Facteur de multiplication (fréquencemètre)
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté !
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté !
4.8 Facteur de division (fréquencemètre)
Le point décimal détermine
la résolution pour les bases
de temps 1/min et 1/sec.
0 pas de décimale
0.0 une décimale
0.00 deux décimales
0.000 trois décimales
4.9 Réglage du point décimal (fréquencemètre)
Le filtre atténue
l’entrée*
* rebonds, par ex. avec des contacts mécaniques
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 27
28 MN05401010E
4.12 Fin de la programmation
La programmation est
exécutée encore une fois.
Les valeurs introduites
peuvent être vérifiées et
modifiées.
La programmation est
terminée et les valeurs
introduites sont prises en
compte comme nouveaux
paramètres.
L’appareil est alors prêt à
fonctionner.
4.10 Mode d’affichage (fréquencemètre)
Conversion et affichage
de la valeur en 1/s
Conversion et affichage
de la valeur en 1/min
4.11 Attente maximale (fréquencemètre)
Cette valeur indique combien de temps le
système doit attendre une impulsion, la mesure
étant en marche, avant d’afficher 0.
Attente maximale 00.1 s
(valeur minimum)
Attente maximale 99,9 s
(valeur maximum)
Compteur à affichage électron-
ique avec 2 plages de totalisation
1. Description
Compteur à affichage à 6 décades avec fonc-
tion Reset
Affichage par LED rouges, hauteur 8 mm
Plage d’affichage de 0 à 999 999
Suppression des zéros de tête
Programmation par deux touches sur la face
avant
Programmation guidée par des messages sur
l’affichage
2. Entrées
INP A
Entrée de comptage dynamique Compteur 1 er
Compteur 2.
RESET
Entrée RESET dynamique couplée en parallèle
avec la touche RESET rouge. Remet le comp-
teur à zéro. Réglable séparément pour le
Compteur 1 et le Compteur 2.
3. Sélection de la valeur affichée
Presser la touche de droite pour commuter entre
l’affichage du totalisateur 1 et celui du totalisa-
teur 2. Une impulsion unique affiche pendant 2 s.
la fonction courante (“total1” ou “total2”). Si la
touche de droite est pressée à nouveau pendant
ce laps de temps, l’affichage passe à la fonction
courante, et (“total1” ou “total2”) s’affiche pen-
dant 2 s. pour confirmation. Ensuite, la valeur de
la fonction sélectionnée s’affiche.
4. Routine de programmation
Les paramètres réglables de l’appareil sont
indiqués ci-dessous dans l’ordre de leur
apparition sur l’affichage. L’appareil est donc
entièrement programmé après un cycle de
programmation.
Les premières valeurs affichées correspondent
au réglage d’usine.
E5524E0402 : Mode de fonctionnement
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 28
MN05401010E 29
français
4.1 Polarité des entrées
npn : commutation à 0 V
pnp : commutation à +U
B
4.2 Activation du filtre 30 Hz(INP A)
Filtre 30 Hz désactivé
(f
max)
Filtre 30 Hz activé
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.3 Facteur de multiplication
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.4 Facteur de division
Le point décimal détermine
la représentation de la
valeur de comptage. Il n’a
aucun effet sur le
comptage.
0 pas de décimale
0.0 une décimale
0.00 deux décimales
0.000 trois décimales
4.5 Réglage du point décimal
4.6 Mode RESET (totalisateur 1)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
4.7 Mode RESET (totalisateur 2)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
Le filtre atténue
l’entrée*
* rebonds, par ex. avec des contacts mécaniques
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 29
30 MN05401010E
4.8 Fin de la programmation
La programmation est
exécutée encore une fois.
Les valeurs introduites
peuvent être vérifiées et
modifiées.
La programmation est
terminée et les valeurs
introduites sont prises en
compte comme nouveaux
paramètres.
L’appareil est alors prêt à
fonctionner.
Totalisateur et compteur de temps
électronique
1. Description
Totalisateur et compteur de temps à 6
décades avec fonction Reset
Affichage par LED rouges, hauteur 8 mm
Plage d’affichage de 0 à 999 999
Suppression des zéros de tête
Programmation par deux touches sur la face
avant
Programmation guidée par des messages sur
l’affichage
Indication de fonctionnement : le point décimal
de la décade la plus faible clignote lorsque la
mesure de temps est active
Modes de mesure de temps :
– Mesure de temps si INP B n’est pas activé
“GAtE.Lo”
Mesure de temps si INP B est activé “GAtE.hi”
– Marche/arrêt de la mesure de temps par le
front INP B “Inb.Inb”
Plages de mesure de temps : h; min; s;
h.min.s
2. Entrées
INP A
Entrée de comptage dynamique du totalisateur.
INP B
Entrée marche/arrêt ou porte du compteur de
temps (en fonction du type d’entrée)
RESET
Entrée RESET dynamique couplée en parallèle
avec la touche RESET rouge. Remet le comp-
teur à zéro. Réglable séparément pour le total-
isateur et pour le compteur de temps.
3. Sélection de la valeur affichée
Presser la touche de droite pour commuter entre
l’affichage du totalisateur et celui du compteur de
temps. Une impulsion unique affiche pendant 2
s. la fonction courante (“total” ou “time”). Si la
touche de droite est pressée à nouveau pendant
ce laps de temps, l’affichage passe à la fonction
courante, et (“total” ou“time”) s’affiche pendant
2 s. pour confirmation. Ensuite, la valeur de la
fonction sélectionnée s’affiche.
E5524E0402 : Mode de fonctionnement
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 30
MN05401010E 31
français
4. Routine de programmation
Les paramètres réglables de l’appareil sont
indiqués ci-dessous dans l’ordre de leur
apparition sur l’affichage. L’appareil est donc
entièrement programmé après un cycle de
programmation.
Les premières valeurs affichées correspondent
au réglage d’usine.
4.1 Polarité des entrées
npn : commutation à 0 V
pnp : commutation à +U
B
4.2 Activation du filtre 30 Hz (INP A, INP B)
Filtre 30 Hz désactivé (f
max)
Entrées de comptage et de
marche/arrêt non amorties
Filtre 30 Hz activé
Entrées de comptage et de
marche/arrêt amorties
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.3 Facteur de multiplication (totalisateur)
Facteur réglable de
00.0001 à 99.9999.
Le réglage à “0” n’est pas
accepté.
4.4 Facteur de division (totalisateur)
Le point décimal détermine
la représentation de la
valeur de comptage. Il n’a
aucun effet sur le comptage.
0 pas de décimale
0.0 une décimale
0.00 deux décimales
0.000 trois décimales
4.5 Réglage du point décimal (totalisateur)
4.6 Mode RESET (totalisateur)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
Marche/arrêt par Inp B.
Mesure du temps si Inp B
(porte) n’est pas actif ou
est ouvert
Marche/arrêt par Inp B.
Mesure du temps si Inp B
(porte) est actif (niveau
haut pour pnp ; niveau bas
pour npn)
Mesure de temps mise en
marche et arrêtée par
INP B (front d’impulsion
montant pour pnp ; front
d’impulsion descendant
pour npn). Chaque front
actif modifie l’état du
comptage.
4.7 Type d’entrée (compteur de temps)
Le filtre atténue
l’entrée*
* rebonds, par ex. avec des contacts mécaniques
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 31
32 MN05401010E
Unité de temps :
secondes (le réglage du
point décimal détermine
la résolution*)
Unité de temps :
minutes (le réglage du
point décimal détermine
la résolution*)
Unité de temps :
heures (le réglage du
point décimal détermine
la résolution*)
Unité de comptage :
Heures:Minutes:Secondes
(le réglage du point
décimal est ignoré)
4.8 Mode de fonctionnement (compteur de
temps)
*0, 0.1, 0.01, 0.001 signifie : mesure du temps
en 0, 0,1, 0,01, 0,001 unités de temps
4.9 Réglage du point décimal (compteur de temps)
Le point décimal
détermine la résolution
de l’unité de temps
programmée.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.11 Fin de la programmation
La programmation est
exécutée encore une fois.
Les valeurs introduites
peuvent être vérifiées et
modifiées.
La programmation est
terminée et les valeurs
introduites sont prises en
compte comme nouveaux
paramètres.
L’appareil est alors prêt à
fonctionner.
4.10 Mode RESET (compteur de temps)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 32
MN05401010E 33
français
Compteur de temps électronique
avec 2 compteurs
1. Description
Compteur de temps à 6 décades avec fonc-
tion Reset
Affichage par LED rouges, hauteur 8 mm
Plage d’affichage de 0 à 999 999
Suppression des zéros de tête
Programmation par deux touches sur la face
avant
Programmation guidée par des messages sur
l’affichage
Indication de fonctionnement : le point décimal
de la décade la plus faible clignote lorsque la
mesure de temps est active
Modes de mesure de temps :
– Mesure de temps si INP B n’est pas activé
“GAtE.Lo”
Mesure de temps si INP B est activé “GAtE.hi”
– Marche/arrêt de la mesure de temps par le
front INP B “Inb.Inb”
– Marche de la mesure par le front Inp A, arrêt
de la mesure par le front INP B (InA.InB)
Plages de mesure de temps : h; min; s;
h.min.s
2. Entrées
INP A
Entrée de “marche” (en fonction du type d’entrée)
INP B
Entrée marche/arrêt ou entrée porte pour le
compteur de temps (en fonction du type d’entrée)
RESET
Entrée RESET dynamique couplée en parallèle
avec la touche RESET rouge. Remet le comp-
teur à zéro. Réglable séparément pour le
Compteur 1 et pour le Compteur 2.
3. Sélection de la valeur affichée
Presser la touche de droite pour commuter entre
l’affichage du compteur de temps 1 et celui du
compteur de temps 2. Une impulsion unique
affiche pendant 2 s. la fonction courante (“time1”
ou “time2”). Si la touche de droite est pressée à
nouveau pendant ce laps de temps, l’affichage
passe à la fonction courante, et (“time1” ou “time2”)
s’affiche pendant 2 s. pour confirmation. Ensuite,
la valeur de la fonction sélectionnée s’affiche.
4. Routine de programmation
Les paramètres réglables de l’appareil sont
indiqués ci-dessous dans l’ordre de leur
apparition sur l’affichage. L’appareil est donc
entièrement programmé après un cycle de
programmation.
Les premières valurs affichées correspondent au
réglage d’usine.
4.1 Polarité des entrées
npn : commutation à 0 V
pnp : commutation à +U
B
4.2 Activation du filtre 30 Hz (INP A, INP B)
Filtre 30 Hz désactivé (f
max)
Entrée de marche/arrêt non
amortie
Filtre 30 Hz activé
Amortissement des entrées
de marche/arrêt pour une
commande par contacts
mécaniques
Le filtre atténue
l’entrée*
* rebonds, par ex. avec des contacts mécaniques
E5524E0402 : Mode de fonctionnement
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 33
34 MN05401010E
Unité de temps : secondes
(le réglage du point déci-
mal détermine la résolu-
tion*)
Unité de temps : minutes
(le réglage du point déci-
mal détermine la résolu-
tion*)
Unité de temps : heures
(le réglage du point déci-
mal détermine la résolu-
tion*)
Unité de comptage :
4.4 Mode de fonctionnement
*0, 0.1, 0.01, 0.001 signifie : mesure du temps
en 0, 0,1, 0,01, 0,001 unités de temps
4.5 Réglage du point décimal
Le point décimal déter-
mine la résolution de
l’unité de temps
programmée.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 Mode RESET (compteur de temps 2)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
Remise à zéro électrique par
l’entrée RESET uniquement
Remise à zéro manuelle
par la touche RESET rouge
uniquement
4.6 Mode RESET (compteur de temps 1)
Remise à zéro manuelle
par la touche RESET rouge
et électrique par l’entrée
RESET
Pas de remise à zéro
(touche RESET rouge et
entrée RESET désactivées)
Marche/arrêt par Inp B.
Mesure du temps si Inp B
(porte) n’est pas actif ou
est ouvert
Marche/arrêt par Inp B.
Mesure du temps si Inp B
(porte) est actif (niveau
haut pour pnp ; niveau
bas pour npn)
Mesure de temps mise
en marche et arrêtée par
INP B (front d’impulsion
montant pour pnp ; front
d’impulsion descendant
pour npn). Chaque front
actif modifie l’état du
comptage.
Mesure de temps mise
en marche par INP A,
arrêtée par INP B. (front
d’impulsion montant pour
pnp ; front d’impulsion
descendant pour npn)
4.3 Type d’entrée (compteur de temps)
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 34
MN05401010E 35
français
4.8 Fin de la programmation
La programmation est
exécutée encore une fois.
Les valeurs introduites
peuvent être vérifiées et
modifiées.
La programmation est
terminée et les valeurs
introduites sont prises en
compte comme nouveaux
paramètres.
L’appareil est alors prêt à
fonctionner.
5. Caractéristiques techniques
Tension d’alimentation
Alimentation : 10 ... 30 V CC/max. 40 mA
avec protection contre les
inversions de polarité
Affichage :
Rouge, 6 décades
LED à 7 segments,
hauteur 8 mm
Mémorisation des données :
EEPROM
Polarité des entrées:
Programmable, npn ou pnp
pour toutes les entrées
Résistance d’entrée :
env. 5 kΩ
Fréquences de comptage :
*signaux rectangulaires,
rapport impulsion/pause 1:1
1)
Start Gate.Lo Inp B non actif
2)
Start InpB.InpB et Inp B connexe avec Inp A
Mesure de fréquence :
Précision : < 0,1 %
Principe de mesure :
<
38 Hz:
Mesure de durée de période
> 38 Hz: Mesure de durée de
portillonnage
durée de potillonage = 23,6 ms
Plages de mesure du temps :
Secondes 0,001 s ... 999 999 s
Minutes 0,001min ... 999 999 min
Heures 0,001 h ... 999 999 h
h.min.s 00 h 00 min 01 s
... 99 h 59 min 59 s
Précision <50 ppm
Durée minimale de l’impulsion sur l’entrée de
remise à zéro : 5 ms
Niveau de commutation des entrées :
Niveau standard :
Low: 0 ... 0,2 x U
B
[V CC]
High: 0,6 x U
B
... 30 [V CC]
U
B
= Tension d’alimentation
Niveau 5 V : Low: 0 ... 2 V CC
High: 4 ...30 V CC
Fome des impulsions :
quelconque*, entrée par
trigger de Schmitt
Température ambiante :
–20 ... +65 °C avec 10 ... 26 V DC
–20 ... +55 °C avec >26 ... 30 V DC
Température de stockage :
–25 ... +70 °C
CEM :
Conforme à la directive CE 2004/108/CEE
Emission de parasites EN 61 000-6-3/
EN 55 011 Classe B
Immunité aux parasites EN 61 000-6-2
Boîtier :
Pour montage dans panneau : 48 x 24 mm
selon DIN 43700, RAL7021, gris foncé
Poids : env. 50 g
Indice de protection : IP 65 (face avant)
Nettoyage:
Les faces avant des appareils ne doivent être
nettoyées qu’avec un chiffon doux humide.
Alimentation CC: 24 V 12 V 10 ... 30 V
Niveau: Standard 5 V
typ. low: 2,5 V 2,0 V 1,0 V
typ. ligh: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
tot.tac 35 20 8
tot.tot 60 20 8
tot.ti
1)
40 20 8
tot.ti
2)
15 10 8
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 35
36 MN05401010E
6. Raccordements 7. La livraison comprend :
1 Afficheur
1 Bride de fixation
1 Cadre pour fixation par bride, pour découpe
d’encastrement 50 x 25 mm
1 Cadre pour fixation par vis, pour découpe
d’encastrement 50 x 25 mm
1 Joint
1 Notice d´utilisation multilingue
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 Reset
8. Dimensions :
48 [1.89]
max. 19.3 [0.76]
22 x 5 [0.87 x 1.77]
24 [0.94]
59 [2.32]
4 [0.16]
6.5 [0.26]
53 [2.09]
50 + 0.6 [1.97 + 0.02]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
26 [1.10]
25 + 0.5
[0.98 + 0.02]
40 [1.57]
56 [2.20]
25 [0.98]
25 x 50
[0.98 x 1.97]
50 [1.97]
M3
1 [0.04]
4 [0.16]
32 [ 1.26]
1
32 ± 0.01
[1.26 ± 0.004]
Fraisure Af3, DIN 74
1
Facade encastrable Découpe d´encastrement :
Découpe d´encastrement :
22,2
+0,3
x 45
+0,6
mm
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 36
MN05401010E 37
deutsch
Bedienungsanleitung
Elektronische Anzeigezähler
E5524E0402
1.1 Sicherheits- und Warnhinweise
Benutzen Sie diese Anzeige nur
– bestimmungsgemäß
– in technisch einwandfreiem
Zustand
– unter Beachtung der Bedien-
ungsanleitung und den allgemei-
nen Sicherheitsbestimmungen.
1.2 Allgemeine Sicherheits- und
Warnhinweise
1. Vor Durchführung von Installations- oder
Wartungsarbeiten stellen Sie bitte sicher, dass
die Digitalanzeige von der Versorgungs-
spannung getrennt ist.
2. Setzen Sie die Digitalanzeige nur
bestimmungsgemäß ein:
In technisch einwandfreiem Zustand.
Unter Beachtung der Bedienungsanleitung
und den allgemeinen
Sicherheitsbestimmungen.
3. Beachten Sie länder- und
anwendungsspezifische Bestimmungen
4. Die Digitalanzeige ist nicht geeingnet für den
explosionsgeschützten Bereich und den
Einsatzbereichen, die in EN 61010 Teil 1
ausgeschlossen sind.
5. Die Digitalanzeige darf nur im ordnungsgemäß
eingebautem Zustand entsprechend dem
Kapitel “Technische Daten” betrieben werden.
1.3 Bestimmungsgemäßer Gebrauch
Die Digitalanzeige darf nur als Einbaugerät
eingesetzt werden. Der Einsatzbereich dieser
Anzeige liegt in industriellen Prozessen und
Steuerungen. In den Bereichen von
Fertigungsstraßen der Metall-, Holz-, Kunststoff-,
Papier-, Glas- und Textilindustrie u.ä.
Überspannungen an den Schraubklemmen der
Digitalanzeige müssen auf den Wert der
Überspannungskategorie II begrenzt sein. Wird
die Digitalanzeige zur Überwachung von
Maschinen oder Ablaufprozessen eingesetzt, bei
denen infolge eines Ausfalls oder einer
Fehlbedienung der Digitalanzeige eine
Beschädigung der Maschine oder ein Unfall des
Bedienungsper-sonals möglich ist, dann müssen
Sie entsprechende Sicherheitsvorkehrungen
treffen.
1.4 Beschreibung
Die Ausführung E5524E0402 ist ein
Universalgerät und verhält sich je nach ein ge -
stell ter Grund be triebs art wie
• ein elektronischer Summier- und Frequenz-
zähler (ab Seite 38)
ein elektronischer Anzeigezähler
mit 2 Summierbereichen (ab Seite 40)
ein elektronischer Summier- und Zeitzähler
(ab Seite 42)
ein elektronischer Zeitzähler mit 2
Zeitzählern (ab Seite 45)
2. Einstellung der Be triebs pa ra me ter
a. Beide Tasten auf der Vor der sei te gedrückt
hal ten und Span nungs ver sor gung ein schal ten,
oder bei eingeschalteter Spannungsver-
sorgung beide Tasten gleichzeitig 5 s drücken.
b. Auf dem Display erscheint
c. Sobald die Tasten los ge las sen werden,
er scheint auf dem Display
c1. durch gedrückt halten der linken Taste und
betätigen der rechten Taste wird der
Programmiervorgang abgebrochen.
c2. durch Drücken der rechten Taste wird auf
umgeschaltet.
d. Umschalten in den ersten Parameter durch
gedrückt halten der linken Taste und betätigen
der rechten Taste.
!
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 37
38 MN05401010E
e. Sobald die Tasten losgelassen werden,
erscheint in sekündlichen Wechsel der
Menütitel und die aktuelle Menüpunkt-
einstellung. Nach Betätigen einer Taste wird
nur noch die Menüpunkteinstellung angezeigt.
f. Durch Drücken der rechten Taste wird die
Me punkt ein stel lung jeweils um einen Wert
wei ter ge schal tet.
Wenn Zahlenwerte ein ge ge ben werden sollen
(z.B. bei der Fak tor ein stel lung), wird mit der
linken Taste zunächst die De ka de angewählt
und dann mit der rech ten der Wert ein ge stellt.
g. Umschalten auf den näch sten Menüpunkt
durch ge drückt halten der linken Taste und
betätigen der rechten Taste.
h. Der jeweils letzte Menütitel „EndPro“
ermöglicht durch An wahl von „YES“ das
Ver las sen des Programmiermenüs und die
Über nah me (Spei che rung) der neuen Werte.
Wird „no“ an ge wählt, be ginnt die
Programmierroutine von vorne, wobei die
zuletzt ein ge stell ten Werte zunächst er hal ten
blei ben. Diese können nun nochmals
verändert oder kon trol liert werden.
3. Programmierroutine
Der erste Menüpunkt ist die Auswahl der Grund -
be triebs art. Diese legt die Funktionen des
Ge tes fest.
Elektronischer Summier- und
Frequenzzähler
1. Beschreibung
6-stelliger Summier- und Frequenzzähler
LED-Anzeige, 8 mm hoch, rot
Anzeigebereich von 0 ... 999 999
Vor nul len un ter drüc kung
Programmierung über zwei frontseitige Tasten
Bedienerführung auf dem Display während
der Programmierung
Umrechnung und Anzeige des Wertes
in 1/s oder 1/min
2. Eingänge
INP A
Dynamischer Zähleingang/Frequenzeingang.
RESET
Dynamischer RESET-Eingang. Dieser ist mit der
roten RESET-Taste parallel geschaltet und setzt
den Zähler auf Null.
3. Auswahl des angezeigten Wertes
Durch drücken der rechten Taste kann zwischen
der Anzeige des Summierzählers und des
Fequenzzählers umgeschaltet werden. Durch
einmaliges Betätigen wird für 2 s die aktuelle
Funktion („totAL“ oder „tAcho“) angezeigt. Wird
innerhalb dieser Zeit die rechte Taste ein zweites
Mal betätigt, so wird zur nächsten Funktion
gewechselt und zur Bestätigung („totAL“ oder
„tAcho“) für 2 s angezeigt. Danach wird der Wert
der ausgewählten Funktion angezeigt.
4. Programmierroutine
Nachfolgend sind die einstellbaren Parameter
des Gerätes aufgeführt, die in der unten
angegebenen Reihenfolge eingestellt werden
können. Nach einem Durchlauf der Routine ist
das Gerät voll stän dig programmiert.
Die zuerst angegebenen Werte entsprechen der
Werkseinstellung.
Betriebsart Summier-
und Frequenzzähler,
weiter unter 4. ab Seite 38
Betriebsart Anzeigezähler
mit 2 Summierbereichen,
weiter unter 4. ab Seite 40
Betriebsart Summier-
und Zeitzähler, weiter
unter 4. ab Seite 43
Betriebsart Zeitzähler mit
2 Zeitbereichen, weiter
unter 4. ab Seite 45
- Technische Änderungen vorbehalten -
E5524E0402: Grundbetriebsart
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 38
MN05401010E 39
deutsch
4.1 Polarität der Eingänge
npn: nach 0 V schal tend
pnp: nach +U
B
schaltend
4.2 Zuschaltung des 30 Hz Filters (INP A)
30 Hz-Filter aus (f
max)
30 Hz-Filter ein
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.3 Multiplikationsfaktor (Summierer)
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.4 Divisionsfaktor (Summierer)
Der Dezimalpunkt legt Dar -
stel lung des Zäh ler stan des
fest. Er hat keinen Einfluß
auf die Zäh lung.
0 keine De zi mal stel le
0.0 eine De zi mal stel le
0.00 zwei De zi mal stel len
0.000 drei De zi mal stel len
4.5 Dezimalpunkteinstellung (Summierer)
4.6 RESET-Mode (Summierer)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rück set -
zung über RESET-Eingang
nur manuelle Rücksetzung
über rote RESET-Taste
4.7 Multitplikationsfaktor (Frequenzzähler)
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert !
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert!
4.8 Divisionsfaktor (Frequenzzähler)
Der Dezimalpunkt definiert
die Auflösung im gewählten
Messbereich 1/min oder
1/sec.
0 keine De zi mal stel le
0.0 eine De zi mal stel le
0.00 zwei De zi mal stel len
0.000 drei De zi mal stel len
4.9 Dezimalpunkteinstellung (Frequenzzähler)
Der Filter bedämpft den
Eingang*
* bei Prellimpulsen, z.B. bei Kontakten
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 39
40 MN05401010E
4.12 Ende der Programmierung
Programmierroutine wird
noch einmal durchlaufen.
Bisher eingestellte Werte
können überprüft und
geändert werden.
Programmierroutine wird
beendet und alle ein ge -
stell ten Werte werden als
neue Parameter
über nom men.
Das Gerät ist an schlie -
ßend betriebsbereit.
4.10 Displaymode (Frequenzzähler)
Umrechnung und Anzeige
des Wertes in 1/s
Umrechnung und Anzeige
des Wertes in 1/min
4.11 Maximale Wartezeit (Frequenzzähler)
Dieser Wert gibt an, wie lange bei gestarteter
Mes sung gewartet werden soll, bis 0 angezeigt
wird.
Maximale Wartezeit 00.1 s
(minimaler Wert)
Maximale Wartezeit
99,9 s (maximaler Wert)
Elektronischer Anzeigezähler mit
2 Summierbereichen
1. Beschreibung
6-stelliger Anzeigezähler mit Reset-Funktion
LED-Anzeige, 8 mm hoch, rot
Anzeigebereich von 0 ... 999 999
Vor nul len un ter drüc kung
Programmierung über zwei frontseitige Tasten
Bedienerführung auf dem Display während
der Programmierung
2. Eingänge
INP A
Dynamischer Zähleingang Zähler 1 und Zähler 2.
RESET
Dynamischer RESET-Eingang. Dieser ist mit der
roten RESET-Taste parallel geschaltet und setzt
den Zähler auf Null. Für Zähler 1 und Zähler 2
getrennt einstellbar
3. Auswahl des angezeigten Wertes
Durch drücken der rechten Taste kann zwischen
der Anzeige des Summierzählers 1 und des
Summierzählers 2 umgeschaltet werden. Durch
einmaliges Betätigen wird für 2 s die aktuelle
Funktion („totAL1“ oder „totAL2“) angezeigt. Wird
innerhalb dieser Zeit die rechte Taste ein zweites
Mal betätigt, so wird zur nächsten Funktion
gewechselt und zur Bestätigung („totAL1“ oder
„totAL2“) für 2 s angezeigt. Danach wird der
Wert der ausgewählten Funktion angezeigt.
4. Programmierroutine
Nachfolgend sind die einstellbaren Parameter
des Gerätes aufgeführt, die in der unten
angegebenen Reihenfolge eingestellt werden
können. Nach einem Durchlauf der Routine ist
das Gerät voll stän dig programmiert.
Die zuerst angegebenen Werte entsprechen der
Werkseinstellung.
E5524E0402: Grundbetriebsart
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 40
MN05401010E 41
deutsch
4.1 Polarität der Eingänge
npn: nach 0 V schal tend
pnp: nach +U
B
schaltend
4.2 Zuschaltung des 30 Hz Filters (INP A)
30 Hz-Filter aus (f
max)
30 Hz-Filter ein
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.3 Multiplikationsfaktor
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.4 Divisionsfaktor
Der Dezimalpunkt legt
Dar stel lung des Zäh ler -
stan des fest. Er hat keinen
Einfluß auf die Zäh lung.
0 keine De zi mal stel le
0.0 eine De zi mal stel le
0.00 zwei De zi mal stel len
0.000 drei De zi mal stel len
4.5 Dezimalpunkteinstellung
4.6 RESET-Mode (Summierer 1)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rück stel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
4.7 RESET-Mode (Summierer 2)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rück stel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
Der Filter bedämpft den
Eingang*
* bei Prellimpulsen, z.B. bei Kontakten
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 41
42 MN05401010E
4.8 Ende der Programmierung
Programmierroutine wird
noch einmal durchlaufen.
Bisher eingestellte Werte
können überprüft und
geändert werden.
Programmierroutine wird
beendet und alle
ein ge stell ten Werte wer-
den als neue Parameter
über nom men.
Das Gerät ist an schlie -
ßend betriebsbereit.
Elektronischer Summier- und
Zeitzähler
1. Beschreibung
6-stelliger Summierer und Zeitzähler mit
Reset-Funktion
LED-Anzeige, 8 mm hoch, rot
Anzeigebereich von 0 ... 999 999
Vor nul len un ter drüc kung
Programmierung über zwei frontseitige Tasten
Bedienerführung auf dem Display während
der Programmierung
Laufanzeige: bei aktiver Zeitmessung blinkt
der Dezimalpunkt der niederwertigsten
Dekade
Zeitmessbetriebsarten:
– Zeitmessung wenn INP B nicht aktiv
„GAtE.Lo“
– Zeitmessung wenn INP B aktiv „GAtE.hi“
– Start/Stop der Zeitmessung
mit Flanke INP B „Inb.Inb“
Zeitmessbereiche: h; min; s; h.min.s
2. Eingänge
INP A
Dynamischer Zähleingang für Summierer.
INP B
Start-/Stop- oder Toreingang für Zeitzähler
(abhängig von der Eingangsart)
RESET
Dynamischer RESET-Eingang. Dieser ist mit der
roten RESET-Taste parallel geschaltet und setzt
den Zähler auf Null. Für Summierer und
Zeitzähler getrennt einstellbar.
3. Auswahl des angezeigten Wertes
Durch drücken der rechten Taste kann zwischen
der Anzeige des Summierzählers und des
Zeitzählers umgeschaltet werden. Durch
einmaliges Betätigen wird für 2 s die aktuelle
Funktion („totAL“ oder „tiME“) angezeigt. Wird
innerhalb dieser Zeit die rechte Taste ein zweites
Mal betätigt, so wird zur nächsten Funktion
gewechselt und zur Bestätigung („totAL“ oder
„tiME“) für 2 s angezeigt. Danach wird der Wert
der ausgewählten Funktion angezeigt.
E5524E0402: Grundbetriebsart
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 42
MN05401010E 43
deutsch
4. Programmierroutine
Nachfolgend sind die einstellbaren Parameter
des Gerätes aufgeführt, die in der unten
angegebenen Reihenfolge eingestellt werden
können. Nach einem Durchlauf der Routine ist
das Gerät voll stän dig programmiert.
Die zuerst angegebenen Werte entsprechen der
Werkseinstellung.
4.1 Polarität der Eingänge
npn: nach 0 V schal tend
pnp: nach +U
B
schaltend
4.2 Zuschaltung des 30 Hz Filters (INP A, INP B)
30 Hz-Filter aus (f
max)
Zähleingang und Start-/
Stopeingang unbedämpft
30 Hz-Filter ein
Zähleingang und Start-/
Stopeingang bedämpft
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.3 Multiplikationsfaktor (Summierer)
Faktor von 00.0001 bis
99.9999 einstellbar.
Eine Einstellung von „0“
wird nicht akzeptiert.
4.4 Divisionsfaktor (Summierer)
Der Dezimalpunkt legt Dar -
stel lung des Zäh ler stan des
fest. Er hat keinen Einfluß
auf die Zäh lung.
0 keine De zi mal stel le
0.0 eine De zi mal stel le
0.00 zwei De zi mal stel len
0.000 drei De zi mal stel len
4.5 Dezimalpunkteinstellung (Summierer)
4.6 RESET-Mode (Summierer)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rückstel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
Start/Stop über Inp B.
Zeitmessung wenn Inp B
(Tor) nicht aktiv oder offen
Start/Stop über Inp B.
Zeitmessung wenn Inp B
(Tor) aktiv (High-Pegel bei
pnp; Low-Pegel bei npn)
Zeitmessung wird mit
INP B ge star tet und
gestoppt (LOW-HIGH
Flanke bei pnp; HIGH-
LOW Flan ke bei npn).
Jede aktive Flanke ändert
Zählstatus.
4.7 Eingangsart (Zeitzähler)
Der Filter bedämpft den
Eingang*
* bei Prellimpulsen, z.B. bei Kontakten
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 43
44 MN05401010E
Zeiteinheit Sekunden
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit: Minuten
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit: Stunden
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit:
Stunden:Minuten:Sekunden
(De zi mal punkt ein stel lung
wird übersprungen)
4.8 Betriebsart (Zeitzähler)
*0, 0.1, 0.01, 0.001 bedeutet: Zeitmessung in 0,
0,1, 0,01, 0,001 Zeiteinheiten (siehe 4.9)
4.9 Dezimalpunkteinstellung (Zeitzähler)
Der Dezimalpunkt legt die
Auflösung der pro gram -
mier ten Zeiteinheit fest.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.10 RESET-Mode (Zeitzähler)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rückstel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
4.11 Ende der Programmierung
Programmierroutine wird
noch einmal durchlaufen.
Bisher eingestellte Werte
können überprüft und
geändert werden.
Programmierroutine wird
beendet und alle
ein ge stell ten Werte wer-
den als neue Parameter
über nom men.
Das Gerät ist an schlie -
ßend betriebsbereit.
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 44
MN05401010E 45
deutsch
Elektronischer Zeitzähler mit
2 Zeitbereichen
1. Beschreibung
6-stelliger Zeitzähler mit Reset-Funktion
LED-Anzeige, 8 mm hoch, rot
Anzeigebereich von 0 ... 999 999
Vor nul len un ter drüc kung
Programmierung über zwei frontseitige Tasten
Bedienerführung auf dem Display während
der Programmierung
Laufanzeige: bei aktiver Zeitmessung blinkt
der Dezimalpunkt der niederwertigsten
Dekade
Zeitmessbetriebsarten:
– Zeitmessung wenn INP B nicht aktiv
„GAtE.Lo“
– Zeitmessung wenn INP B aktiv „GAtE.hi“
– Start/Stop der Zeitmessung mit Flanke INP B
(Inb.Inb)
– Start der Zeitmessung mit Flanke Inp A,
Stop der Zeitmessung mit Flanke INP B
(InA.InB)
Zeitmessbereiche: h; min; s; h.min.s
2. Eingänge
INP A
Starteingang (abhängig von der Eingangsart)
INP B
Start-/Stop- oder Toreingang für Zeitzähler
(abhängig von der Eingangsart)
RESET
Dynamischer RESET-Eingang. Dieser ist mit der
roten RESET-Taste parallel geschaltet und setzt
den Zähler auf Null. Für Zähler 1 und Zähler 2
getrennt einstellbar.
3. Auswahl des angezeigten Wertes
Durch drücken der rechten Taste kann zwischen
der Anzeige des Zeitzählers 1 und des
Zeitzählers 2 umgeschaltet werden. Durch
einmaliges Betätigen wird für 2 s die aktuelle
Funktion („tiME1“ oder „tiME2“) angezeigt. Wird
innerhalb dieser Zeit die rechte Taste ein zweites
Mal betätigt, so wird zur nächsten Funktion
gewechselt und zur Bestätigung („tiME1“ oder
„tiME2“) für 2 s angezeigt. Danach wird der Wert
der ausgewählten Funktion angezeigt.
4. Programmierroutine
Nachfolgend sind die einstellbaren Parameter
des Gerätes aufgeführt, die in der unten
angegebenen Reihenfolge eingestellt werden
können. Nach einem Durchlauf der Routine ist
das Gerät voll stän dig programmiert.
Die zuerst angegebenen Werte entsprechen der
Werkseinstellung.
4.1 Polarität der Eingänge
npn: nach 0 V schal tend
pnp: nach +U
B
schaltend
4.2 Zuschaltung des 30 Hz Filters (INP A, INP
30 Hz-Filter aus (f
max)
Start-/Stopeingang
unbedämpft
30 Hz-Filter ein
Bedämpfung der Start und
Stopeingänge
Der Filter bedämpft den
Eingang*
* bei Prellimpulsen, z.B. bei Kontakten
E5524E0402: Grundbetriebsart
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 45
46 MN05401010E
Zeiteinheit Sekunden
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit: Minuten
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit: Stunden
(De zi mal punkt ein stel lung
bestimmt Auf sung*)
Zeiteinheit:
Stunden:Minuten:Sekunden
(De zi mal punkt ein stel lung
wird übersprungen)
4.4 Betriebsart
*0, 0.1, 0.01, 0.001 bedeutet: Zeitmessung in 0,
0,1, 0,01, 0,001 Zeiteinheiten
4.5 Dezimalpunkteinstellung
Der Dezimalpunkt legt die
Auflösung der pro gram -
mier ten Zeiteinheit fest.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 RESET-Mode (Zeitbereich 2)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
nur elektrische Rückstel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
nur elektrische Rückstel -
lung über RESET-Eingang
nur manuelle Rückstellung
über rote RESET-Taste
4.6 RESET-Mode (Zeitbereich 1)
manuelle Rückstellung über
die rote RESET-Taste und
elek tri sche Rückstellung
über RESET-Eingang
keine Rückstellung mög lich
(rote RESET-Taste und
RESET-Eingang gesperrt)
Start/Stop über Inp B.
Zeitmessung wenn Inp B
(Tor) nicht aktiv oder offen
Start/Stop über Inp B.
Zeitmessung wenn Inp B
(Tor) aktiv (High-Pegel bei
pnp; Low-Pegel bei npn)
Zeitmessung wird mit
INP B ge star tet und
gestoppt (LOW-HIGH
Flanke bei pnp; HIGH-
LOW Flan ke bei npn).
Jede aktive Flanke ändert
Zählstatus.
Zeitmessung wird mit
INP A ge star tet, mit INP B
gestoppt. (LOW-HIGH
Flanke bei pnp; HIGH-
LOW Flanke bei npn)
4.3 Eingangsart (Zeitzähler)
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 46
MN05401010E 47
deutsch
4.8 Ende der Programmierung
Programmierroutine wird
noch einmal durchlaufen.
Bisher eingestellte Werte
können überprüft und
geändert werden.
Programmierroutine wird
beendet und alle
ein ge stell ten Werte wer-
den als neue Parameter
über nom men.
Das Gerät ist an schlie -
ßend betriebsbereit.
5. Technische Daten
Spannungsversorgung
Versorgung: 10 ... 30 V DC/max. 40 mA
mit Verpolschutz
Anzeige: 6-stellige rote 7-Segment
LED-Anzeige, 8 mm hoch
Datensicherung: EEPROM
Polarität der Eingänge:
Programmierbar, npn oder
pnp für alle Eingänge
Eingangswiderstand:
ca. 5 kΩ
Zählfrequenzen:
1)
Start Gate.Lo Inp B nicht aktiv
2)
Start InpB.InpB und Inp B mit Inp A verbunden
*bei maximaler Frequenz Rechteckimpulse 1:1
Frequenzmessung:
Genauigkeit: < 0,1 %
Messprinzip:
<
38Hz: Periodendauermessung
> 38 Hz: Torzeitmessung
Torzeit 26,3 ms
Zeitmessbereiche:
Sekunden 0,001 s ... 999 999 s
Minuten 0,001min ... 999 999 min
Stunden 0,001 h ... 999 999 h
h.min.s 00 h 00 min 01 s
... 99 h 59 min 59 s
Genauigkeit <50 ppm
Mindestimpulsdauer des Rücksetzeingangs:
5 ms
Schaltpegel der Eingänge:
Standard-Pegel:
Low: 0 ... 0,2 x U
B
[V DC]
High: 0,6 x U
B
... 30 [V DC]
U
B
= Netzspannung
5 V-Pegel: Low: 0 ... 2 V DC
High: 4 ...30 V DC
Impulsform: beliebig*,
Schmitt-Trigger-Eingang
Umgebungstemperatur:
–20 ... +65 °C bei 10 ... 26 V DC
–20 ... +55 °C bei >26 ... 30 V DC
Lagertemperatur:
–25 ... +70 °C
EMV:
CE-Konform zur EG-Richtlinie 2004/108/EWG
Störabstrahlung EN 61 000-6-3
EN 55 011 Klasse B
Störfestigkeit EN 61 000-6-2
Gehäuse:
Schalttafelgehäuse: 48 x 24 mm
nach DIN 43700, RAL7021, dunkelgrau
Gewicht: ca. 50 g
Schutzart: IP 65 (frontseitig)
Reinigung:
Die Frontseiten der Geräte dürfen nur mit einem
weichen, mit Wasser angefeuchteten Tuch
gereinigt werden.
DC-Versorgung 24 V 12 V 10 ... 30 V
Eingangspegel: Standard 5 V
typ. Low Pegel: 2,5 V 2,0 V 1,0 V
typ. High Pegel: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
tot.tac 35 20 8
tot.tot 60 20 8
tot.ti
1)
40 20 8
tot.ti
2)
15 10 8
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 47
48 MN05401010E
6. Anschlussbelegung
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 Reset
7. Lieferumfang:
1 Digitalanzeige
1 Spannbügel
1 Frontrahmen für Spannbügelbefestigung,
für Einbauquerschnitt 50 x 25 mm
1 Frontrahmen für Schraubbefestigung,
für Einbauquerschnitt 50 x 25 mm
1 Dichtung
1 Bedienungsanleitung multilingual
8. Abmessungen:
48 [1.89]
max. 19.3 [0.76]
22 x 5 [0.87 x 1.77]
24 [0.94]
59 [2.32]
4 [0.16]
6.5 [0.26]
53 [2.09]
50 + 0.6 [1.97 + 0.02]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
26 [1.10]
25 + 0.5
[0.98 + 0.02]
40 [1.57]
56 [2.20]
25 [0.98]
25 x 50
[0.98 x 1.97]
50 [1.97]
M3
1 [0.04]
4 [0.16]
32 [ 1.26]
1
32 ± 0.01
[1.26 ± 0.004]
Senkung Af3, DIN 74
1
Schalttafelausschnitt:
22,2+0,3 x 45+0,6 mm
Einbaurahmen Schalttafelausschnitt:
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 48
MN05401010E 49
italiano
Istruzioni per l’uso
Contatori con display elettronici
E5524E0402
1.1 Istruzioni per la sicurezza e
avvertenze
Utilizzare questi visualizzatori solo
– in maniera conforme alla loro
destinazione
– se la loro condizione tecnica è
perfetta
– osservando le istruzioni di utilizzo
e le norme generali di sicurezza.
1.2 norme generali di sicurezza.
1. Prima di qualsiasi lavoro d'installazione o di
manutenzione, accertarsi che l’alimentazione
del visualizzatore digitale sia interrotta.
2. Utilizzare questo visualizzatore solo in
maniera conforme alla sua destinazione:
La sua condizione tecnica deve essere perfetta.
Osservare le istruzioni di utilizzo e le norme
generali di sicurezza.
3. Rispettare le norme specifiche al paese e
all’utilizzatore.
4. Il visualizzatore digitale non conviene per
delle zone che presentino rischi d'esplosione,
né per i campi d'utilizzo esclusi della norma
EN 61010, Parte 1.
5. Il visualizzatore digitale deve funzionare solo
se è stato inserito a regola d’arte, in
conformità con le prescrizioni del capitolo
“Caratteristiche tecniche generali”.
1.3 Utilizzazione in conformità
Il visualizzatore digitale può essere utilizzato solo
in qualità d'apparecchiatura incassata. Questo
prodotto trova la sua applicazione nei processi
industriali ed i comandi, nel campo delle linee di
produzione delle industrie metallurgiche, del
legno, delle materie plastiche, della carta, del
vetro, dei tessili eccetera.
Le sovratensioni ai terminali dell’apparecchiatura
devono essere limitate ai valori della categoria di
sovratensione II
.
Se il visualizzatore digitale è utilizzato per la
sorveglianza di macchine o di processi ove, in
caso di guasto o di errori di manipolazione
dell’apparecchio, possano presentarsi rischi di
danni alla macchina o d’incidenti per gli operatori,
l’utente deve assumere la responsabilità per le
opportune misure di sicurezza.
1.4 Descrizione
Il modello E5524E0402 è stato concepito in
modo tale da farne un apparecchio universale.
Secondo il modo di funzionamento selezionato,
esso si comporta come
un totalizzatore e frequenzimetro elettroni-
co (vedi pagina 50)
un contatore con display elettronico, con 2
campi di totalizzazione (vedi pagina 52)
un totalizzatore e contatore di tempo
elettronico (vedi pagina 54)
un contatore di tempo elettronico con 2
contatori di tempo (vedi pagina 57)
2. Regolazione dei parametri di
funzionamento
a. Premere i due tasti sulla parte anteriore e
mettere l’apparecchio sotto tensione o,
qualora l’apparecchio sia sotto tensione,
premere i due tasti per 5 secondi.
b. Sul display compare il seguente messaggio
c. Al rilascio dei tasti, il display visualizza
c1.Mantenere il tasto sinistro premuto, poi
premere il tasto destro per interrompere
l’operazione di programmazione.
c2.Premere il tasto destro. Il display indica
.
d. Mantenere il tasto sinistro premuto, poi
premere il tasto destro per richiamare il primo
parametro.
!
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 49
e. Al rilascio dei tasti, compare, ad intervalli di
un secondo, il titolo del menu e la regolazione
del punto del menu in essere. Premere un
tasto: la visualizzazione alternata cessa ed il
display indica solo la regolazione del punto
del menu.
f. Un impulso sul tasto destro consente di
passare al valore successivo del parametro in
fase di regolazione.
Per inserire dei dati numerici (per esempio al
momento della regolazione del fattore),
selezionare prima la decade tramite il tasto
sinistro, poi regolare il suo valore con il tasto
destro.
g. Mantenere il tasto sinistro premuto, poi pre-
mere il tasto destro per richiamare il punto
successivo del menu.
h. L’ultimo parametro del menu “EndPro”
permette, selezionando “Yes”, di uscire dal
menu di programmazione e di salvare i nuovi
valori. Selezionando “no”, la programmazione
riparte dall’inizio, conservando gli ultimi valori
inseriti. In questo modo, è possibile controllar-
li e modificarli di nuovo.
3. Routine di programmazione
Il primo punto del menu è la selezione del modo
di funzionamento base. Determina le funzioni
dell’apparecchio.
Totalizzatore e frequenzimetro
elettronico
1. Descrizione
Totalizzatore e frequenzimetro a 6 decadi
Display a LED rossi, altezza 8 mm
Campo di visualizzazione 0 ... 999 999
Soppressione degli zeri in testa
Programmazione tramite due tasti sulla parte
frontale
Programmazione guidata tramite messaggi sul
display
Conversione e visualizzazione del valore in
1/s o 1/min
2. Entrate
INP A
Entrata di conteggio/di frequenza dinamica.
RESET
Entrata RESET dinamica accoppiata in parallelo
con il tasto RESET rosso. Azzera il contatore.
3. Selezione del valore visualizzato
Premere il tasto destro per commutare dal dis-
play del totalizzatore a quello del frequenzimetro.
Un impulso unico visualizza per 2 secondi la
funzione corrente (“total” o “tacho”). Qualora il
tasto di destra sia premuto nuovamente durante
questo lasso di tempo, il sistema passa alla
funzione corrente ed il display visualizza (“total”
o “tacho”) per 2 secondi per confermare. In
seguito, il valore della funzione selezionata è
visualizzato.
4. Routine di programmazione
I parametri regolabili dell’apparecchio sono
indicati di seguito nell’ordine in cui sono visualiz-
zati sul display. Perciò, la programmazione
dell’apparecchio è completata dopo un ciclo di
programmazione.
I primi valori indicati corrispondono a quelli
regolati in fabbrica.
50 MN05401010E
Modo contatore totalizza-
tore e frequenzimetro,
vedi par. 4, pagina 50
Modo contatore con display,
con 2 campi di totalizzazione,
vedi par. 4, pagina 52
Modo contatore totalizza-
tore e contatore di tempo,
vedi par. 4, pagina 55
Modo contatore di tempo
con 2 contatori di tempo,
vedi par. 4, pagina 57
- Sotto riserva di modifiche tecniche -
E5524E0402:
Modo di funzionamento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 50
MN05401010E 51
italiano
4.1 Polarità delle entrate
npn: commutazione a 0 V
pnp: commutazione a +U
B
4.2 Attivazione del filtro 30Hz (INP A)
Filtro 30 Hz disattivato
(f
max
)
Filtro 30 Hz attivato
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.3 Fattore di moltiplicazione (totalizzatore)
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.4 Fattore di divisione (totalizzatore)
Il punto decimale determina
la rappresentazione del
valore di conteggio. Non ha
nessun effetto sul
conteggio.
0 nessuna decimale
0.0 una decimale
0.00 due decimali
0.000 tre decimali
4.5 Regolazione del punto decimale (totalizza
tore)
4.6 Modo RESET (totalizzatore)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
4.7 Fattore di moltiplicazione (frequenzimetro)
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non
è accettata.
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non
è accettata.
4.8 Fattore di divisione (frequenzimetro)
Il punto decimale determina
la risoluzione.
0 nessuna decimale
0.0 una decimale
0.00 due decimali
0.000 tre decimali
4.9 Regolazione del punto decimale (frequen
zimetro)
Il filtro permette di
impostare la frequenza
max di conteggio
all’ingresso*
* dove si verifica una pendolazione, per esempio con i
contatti
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 51
52 MN05401010E
4.12 Fine della programmazione
La programmazione è
realizzata ancora una volta.
I valori inseriti possono
essere controllati e modifi-
cati.
La programmazione è
conclusa ed i valori inseriti
sono presi in consider-
azione come nuovi para-
metri.
Ora, l’apparecchio è pron-
to per il funzionamento.
4.10 Modo di visualizzazione (frequenzimetro)
Conversione e visualiz-
zazione del valore in 1/s
Conversione e visualiz-
zazione del valore in 1/min
4.11 Attesa massima (frequenzimetro)
Questo valore indica quanto tempo il sistema
deve aspettare un impulso, la misura essendo
attiva, prima di visualizzare 0.
Attesa massima 00.1 s
(valore minimo)
Attesa massima 99,9 s
(valore massimo)
Contatore con display elettronico,
con 2 campi di totalizzazione
1. Descrizione
Contatore con display a 6 decadi, con fun-
zione Reset
Display a LED rossi, altezza 8 mm
Campo di visualizzazione 0 ... 999 999
Soppressione degli zeri in testa
Programmazione tramite due tasti sulla parte
frontale
Programmazione guidata tramite messaggi sul
display.
2. Entrate
INP A
Entrata di conteggio dinamica Contatore 1 e
Contatore 2.
RESET
Entrata RESET dinamica accoppiata in parallelo
con il tasto RESET rosso. Azzera il contatore.
Regolabile separatamente per il contatore 1 e il
contatore 2.
3. Selezione del valore visualizzato
Premere il tasto destro per commutare dal
display del totalizzatore 1 a quello del totalizza-
tore 2. Un impulso unico visualizza per 2 secondi
la funzione corrente (“total1” o “total2”). Qualora
il tasto di destra sia premuto nuovamente
durante questo lasso di tempo, il sistema passa
alla funzione corrente ed il display visualizza
(“total1” o “total2”) per 2 secondi per confermare.
In seguito, il valore della funzione selezionata è
visualizzato.
4. Routine di programmazione
I parametri regolabili dell’apparecchio sono
indicati di seguito nell’ordine in cui sono visualiz-
zati sul display. Perciò, la programmazione
dell’apparecchio è completata dopo un ciclo di
programmazione.
I primi valori indicati corrispondono a quelli
regolati in fabbrica.
E5524E0402:
Modo di funzionamento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 52
MN05401010E 53
italiano
4.1 Polarità delle entrate
npn: commutazione a 0 V
pnp: commutazione a +U
B
4.2 Attivazione del filtro 30Hz (INP A)
Filtro 30 Hz disattivato
(f
max
)
Filtro 30 Hz attivato
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.3 Fattore di moltiplicazione
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.4 Fattore di divisione
Il punto decimale determina
la rappresentazione del
valore di conteggio. Non ha
nessun effetto sul
conteggio.
0 nessuna decimale
0.0 una decimale
0.00 due decimali
0.000 tre decimali
4.5 Regolazione del punto decimale
4.6 Modo RESET (totalizzatore 1)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
4.7 Modo RESET (totalizzatore 2)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
Il filtro permette di
impostare la frequenza
max di conteggio
all’ingresso*
* dove si verifica una pendolazione, per esempio con i
contatti
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 53
54 MN05401010E
4.8 Fine della programmazione
La programmazione è
realizzata ancora una volta.
I valori inseriti possono
essere controllati e
modificati.
La programmazione è
conclusa ed i valori
inseriti sono presi in
considerazione come
nuovi parametri.
Ora, l’apparecchio è
pronto per il
funzionamento.
Totalizzatore e contatore di tempo
elettronico
1. Descrizione
Totalizzatore e contatore di tempo a 6 decadi,
con funzione Reset
Display a LED rossi, altezza 8 mm
Campo di visualizzazione 0 ... 999 999
Soppressione degli zeri in testa
Programmazione tramite due tasti sulla parte
frontale
Programmazione guidata tramite messaggi sul
display
Indicazione di funzionamento: il punto deci-
male della decade più bassa lampeggia quan-
do la misura di tempo è attiva
Modi di funzionamento per la misura di tempo:
– Misura se INP B non è attivo “GAtE.Lo”
– Misura se INP B è attivo “GAtE.hi”
– Start/Stop della misura tramite fronte INP B
“Inb.Inb”
Campi di misura di tempo: h; min; s; h.min.s
2. Entrate
INP A
Entrata di conteggio dinamica per il totalizzatore.
INP B
Entrata di Start-/Stop o entrata di porta per il
contatore di tempo (secondo il tipo d’entrata
selezionato)
RESET
Entrata RESET dinamica accoppiata in parallelo
con il tasto RESET rosso. Azzera il contatore.
Regolabile separatamente per il totalizzatore e
per il contatore di tempo.
3. Selezione del valore visualizzato
Premere il tasto destro per commutare dal
display del totalizzatore a quello del contatore di
tempo. Un impulso unico visualizza per 2 secon-
di la funzione corrente (“total” o “time”). Qualora
il tasto di destra sia premuto nuovamente
durante questo lasso di tempo, il sistema passa
alla funzione corrente ed il display visualizza
(“tota1” o “timer”) per 2 secondi per confermare.
In seguito, il valore della funzione selezionata è
visualizzato.
E5524E0402:
Modo di funzionamento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 54
MN05401010E 55
italiano
4. Routine di programmazione
I parametri regolabili dell’apparecchio sono
indicati di seguito nell’ordine in cui sono visualiz-
zati sul display. Perciò, la programmazione
dell’apparecchio è completata dopo un ciclo di
programmazione.
I primi valori indicati corrispondono a quelli
regolati in fabbrica.
4.1 Polarità delle entrate
npn: commutazione a 0 V
pnp: commutazione a +U
B
4.2 Attivazione del filtro 30Hz (INP A, INP B)
Filtro 30 Hz disattivato (f
max)
Entrate di conteggio e di
Start-Stop non amortizzate
Filtro 30 Hz attivato
Entrate di conteggio e di
Start-Stop amortizzate
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.3 Fattore di moltiplicazione (totalizzatore)
Fattore regolabile da
00.0001 a 99.9999.
La regolazione a “0” non è
accettata.
4.4 Fattore di divisione (totalizzatore)
Il punto decimale determina la
rappresentazione del valore di
conteggio. Non ha nessun
effetto sul conteggio.
0 nessuna decimale
0.0 una decimale
0.00 due decimali
0.000 tre decimali
4.5 Regolazione del punto decimale (totalizzatore)
4.6 Modo RESET (
totalizzatore
)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET rosso
Start/Stop tramite Inp B.
Misura di tempo se Inp B
(porta) non è attivo o è
aperto
Start/Stop tramite Inp B.
Misura di tempo se Inp B
(porta) è attivo (livello alto
per pnp; livello basso per
npn)
Start e Stop della misura
di tempo tramite INP B
(fronte d’impulso ascen-
dente per pnp; fronte dis-
cendente per npn). Ogni
fronte attiva modifica lo
stato del conteggio.
4.7 Tipo d’entrata (contatore di tempo)
Il filtro permette di
impostare la frequenza max
di conteggio all’ingresso*
* dove si verifica una pendolazione, per esempio con i
contatti
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 55
56 MN05401010E
Unità di tempo: secondi (la
regolazione del punto deci-
male determina la risoluzione*)
Unità di tempo: minuti (la rego-
lazione del punto decimale
determina la risoluzione*)
Unità di tempo: ore (la rego-
lazione del punto decimale
determina la risoluzione*)
Unità di conteggio:
Ore:Minuti:Secondi (la
regolazione del punto
decimale è ignorata)
4.8 Modo di funzionamento (contatore di tempo)
*0, 0.1, 0.01, 0.001 significa: misura di tempo in
0, 0,1, 0,01, 0,001 unità di tempo
4.9 Regolazione del punto decimale
(contatore di tempo)
Il punto decimale determi-
na la risoluzione dell’unità
di tempo programmata.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.11 Fine della programmazione
La programmazione è
realizzata ancora una volta.
I valori inseriti possono
essere controllati e modifi-
cati.
La programmazione è
conclusa ed i valori
inseriti sono presi in
considerazione come
nuovi parametri.
Ora, l’apparecchio è
pronto per il
funzionamento.
4.10 Modo RESET (contatore di tempo)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 56
MN05401010E 57
italiano
Contatore di tempo elettronico
con 2 contatori
1. Descrizione
Contatore di tempo a 6 decadi, con funzione
Reset
Display a LED rossi, altezza 8 mm
Campo di visualizzazione 0 ... 999 999
Soppressione degli zeri in testa
Programmazione tramite due tasti sulla parte
frontale
Programmazione guidata tramite messaggi sul
display
Indicazione di funzionamento: il punto deci-
male della decade più bassa lampeggia quan-
do il conteggio è attivo.
Modi di funzionamento per la misura di tempo:
– Misura se INP B non è attivo “GAtE.Lo”
– Misura se INP B è attivo “GAtE.hi”
– Start/Stop della misura tramite fronte INP B
(Inb.Inb)
– Start della misura tramite fronte Inp A, Stop
della misura tramite fronte INP B (InA.InB)
Campi di misura di tempo: h; min; s; h.min.s
2. Entrate
INP A
Entrata di Start (secondo il tipo d’entrata selezionato)
INP B
Entrata di Start/Stop o entrata di porta per il conta-
tore di tempo (secondo il tipo d’entrata selezionato)
RESET
Entrata RESET dinamica accoppiata in parallelo
con il tasto RESET rosso. Azzera il contatore.
Regolabile separatamente per il contatore 1 e il
contatore 2.
3. Selezione del valore visualizzato
Premere il tasto destro per commutare dal
display del contatore di tempo 1 a quello del
contatore di tempo 2. Un impulso unico visualiz-
za per 2 secondi la funzione corrente (“time1” o
“time2”). Qualora il tasto di destra sia premuto
nuovamente durante questo lasso di tempo, il
sistema passa alla funzione corrente ed il display
visualizza (“time1” o “time2”) per 2 secondi per
confermare. In seguito, il valore della funzione
selezionata è visualizzato.
4. Routine di programmazione
I parametri regolabili dell’apparecchio sono
indicati di seguito nell’ordine in cui sono visualiz-
zati sul display. Perciò, la programmazione
dell’apparecchio è completata dopo un ciclo di
programmazione.
I primi valori indicati corrispondono a quelli
regolati in fabbrica.
4.1 Polarità delle entrate
npn: commutazione a 0 V
pnp: commutazione a +U
B
4.2 Attivazione del filtro 30Hz (INP A, INP B)
Filtro 30 Hz disattivato (f
max)
Entrate di Start/Stop non
amortizzate
Filtro 30 Hz attivato
Amortizzamento delle
entrate di Start/Stop per
un comando per contatti
meccanici
Il filtro permette di
impostare la frequenza max
di conteggio all’ingresso*
* dove si verifica una pendolazione, per esempio con i
contatti
E5524E0402:
Modo di funzionamento
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 57
58 MN05401010E
Unità di tempo: secondi (la
regolazione del punto decimale
determina la risoluzione*)
Unità di tempo: minuti (la rego-
lazione del punto decimale
determina la risoluzione*)
Unità di tempo: ore (la rego-
lazione del punto decimale
determina la risoluzione*)
Unità di conteggio:
Ore:Minuti:Secondi (la
regolazione del punto
decimale è ignorata)
4.4 Modo di funzionamento
*0, 0.1, 0.01, 0.001 significa: misura di tempo in
0, 0,1, 0,01, 0,001 unità di tempo
4.5 Regolazione del punto decimale
Il punto decimale determi-
na la risoluzione dell’unità
di tempo programmata.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 Modo RESET (contatore di tempo 2)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
Solo ripristino elettrico
tramite l’entrata RESET
Solo ripristino manuale
tramite il tasto RESET
rosso
4.6 Modo RESET (contatore di tempo 1)
Ripristino manuale tramite il
tasto RESET rosso ed
elettrico tramite l’entrata
RESET
Nessun ripristino (tasto
RESET rosso ed entrata
RESET disattivati)
Start/Stop tramite Inp B.
Misura di tempo se Inp B
(porta) non è attivo o è
aperto.
Start/Stop tramite Inp B.
Misura di tempo se Inp B
(porta) è attivo (livello alto
per pnp; livello basso per
npn)
Start e Stop della misura
di tempo tramite INP B
(fronte d’impulso ascen-
dente per pnp; fronte dis-
cendente per npn). Ogni
fronte attiva modifica lo
stato del conteggio.
Start della misura di tempo
tramite INP A, Stop tramite
INP B. (fronte d’impulso
ascendente per pnp; fronte
discendente per npn)
4.3 Tipo d’entrata (contatore di tempo)
MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 58
5. Caratteristiche tecniche
Tensione d’alimentazione
Alimentazione: 10 ... 30 V CC/max. 40 mA
Con protezione contro le
inversioni di polarità
Display: 6 decadi, LED rossi a
7 segmenti, altezza 8 mm
Memorizzazione dei dati:
EEPROM
Polarità delle entrate:
Programmabile, npn o pnp
per tutte le entrate
Resistenza d’entrata:
circa. 5 kΩ
Frequenze di conteggio:
1)
Start Gate.Lo Inp B non actif
2)
Start InpB.InpB è Inp B con Inp A
* alla massima frequenza l’onda quadra è 1:1
MN05401010E 59
italiano
4.8 Fine della programmazione
La programmazione è
realizzata ancora una
volta. I valori inseriti pos-
sono essere controllati e
modificati.
La programmazione è con-
clusa ed i valori inseriti
sono presi in consider-
azione come nuovi para-
metri.
Ora, l’apparecchio è pron-
to per il funzionamento.
Misura di frequenza:
Precisione: < 0,1 %
Principio di misura:
< 38 Hz:
Misura di durata di periodo
> 38 Hz: Misura del tempo di porta
tempo di porta = 26,6 ms
Campi di misura del tempo:
Secondi 0,001 s ... 999 999 s
Minuti 0,001min ... 999 999 min
Ore 0,001 h ... 999 999 h
h.min.s 00 h 00 min 01 s
... 99 h 59 min 59 s
Precisione <50 ppm
Durata minima dell’impulso sull’entrata di
rimessa a zero: 5 ms
Livello di commutazione delle entrate:
Livello standard:
Low: 0 ... 0,2 x U
B
[V CC]
High: 0,6 x U
B
... 30 [V CC]
U
B
= Tensione di
alimentazione
Livello 5 V: Low: 0 ... 1 V CC
High: 4 ...30 V CC
Forma degli impulsi:
qualsiasi*, entrata tramite
trigger di Schmitt
Temperatura ambiente:
–20 ... +65 °C a 10 ... 26 V DC
–20 ... +55 °C a >26 ... 30 V DC
Temperatura di immagazzinamento:
–25 ... +70 °C
CEM :
Conforme alla direttiva CE 2004/108/CEE
Emissione di parassiti
EN EN 61 000-6-3/
EN 55 011 Classe B
Immunità ai parasiti EN 61 000-6-2
Contenitore :
Per montaggio in pannello:48 x 24 mm
in accordo con DIN 43700, RAL7021, grigio scuro
Peso: circa 50 g
Grado di protezione:
IP 65 (frontale)
Pulizia :
Le parti frontali degli apparecchi devono essere
pulite esclusivamente con uno straccio morbido
umido.
Alimentazione CC: 24 V 12 V 10 ... 30 V
Livello: Standard 5 V
typ. low: 2,5 V 2,0 V 1,0 V
typ. high: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
tot.tac 35 20 8
tot.tot 60 20 8
tot.ti
1)
40 20 8
tot.ti
2)
15 10 8
MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 59
60 MN05401010E
6. Collegamenti 7. La consegna include
1 Display digitale
1 Staffa di fissaggio
1 frontale per montaggio con viti, pannelo 50 x 25
1 clip per lannello di montaggio, pannelo 50 x 50
1 Sigillare
1 Manuale operativo multilingua
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 Reset
8. Dimensioni:
48 [1.89]
max. 19.3 [0.76]
22 x 5 [0.87 x 1.77]
24 [0.94]
59 [2.32]
4 [0.16]
6.5 [0.26]
53 [2.09]
50 + 0.6 [1.97 + 0.02]
1 [0.04]
4 [0.16]
25 x 50
[0.98 x 1.97]
26 [1.10]
25 + 0.5
[0.98 + 0.02]
40 [1.57]
56 [2.20]
25 [0.98]
25 x 50
[0.98 x 1.97]
50 [1.97]
M3
1 [0.04]
4 [0.16]
32 [ 1.26]
1
32 ± 0.01
[1.26 ± 0.004]
Accecatura Af3, DIN 74
1
Sfinestratura pannello:
22,2
+0,3
x 45
+0,6
mm
Cornice anteriore Sfinestratura pannello:
MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 60
MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 61
Eaton is a registered trademark of
Eaton Corporation.
All trademarks are property of their
respective owners.
Eaton Corporation
Electrical Sector
1111 Superior Ave.
Cleveland, OH 44114 USA
Eaton.com
© 2012 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. MN05401010E / Z12462
July 2012
MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 62

Transcripción de documentos

7/31/12 9:10 AM Page 1 english Operating Instructions Electronic Display Counter E5524E0402 1.4 Description Only use this display – according to its intended purpose – if its technical condition is perfect – adhering to the operating instructions and the general safety instructions. E5524E0402 is a multipurpose device. Depending on the programmed basic function, the device operates like • an electronic totalizer and frequency meter (see page 2) • an electronic display counter with 2 totalizing ranges (see page 4) • an electronic totalizer and time meter (see page 6) • an electronic time meter with 2 time ranges (see page 9) 1.2 General safety instructions 1. Before carrying out any installation or maintenance work, make sure that the power supply of the digital display is switched off. 2. Only use this digital display according to its intended purpose: If its technical condition is perfect. Adhering to the operating instructions and the general safety instructions. 3. Adhere to country or user specific regulations. 4. The digital display is not intended for use in areas with risks of explosion and in the branches excluded by the standard EN 61010 Part 1. 5. The digital display shall only operated if it has been correctly mounted in a panel, in accordance with the chapter “Main technical features”. 2. Setting of the operating parameters a. Press both front side keys and switch on the supply voltage or, if the supply voltage is already on, press both keys simultaneously for 5 s. b. The display shows deutsch ! français 1.1 Safety instructions and warnings español MN05401010E.qxd:MN05401010E c. After releasing the keys, the display shows The digital display may only be used as a panelmounted device. Applications of this product may be found in industrial processes and controls, in manufacturing lines for the metal, wood, plastics, paper, glass, textile and other processing industries. Over-voltages at the terminals of the digital display must be kept within the limits in Category II. If the digital display is used to monitor machines or processes in which, in case of a failure of the device or an error made by the operator, there might be risks of damaging the machine or causing accidents to the operators, it is your responsibility to take appropriate safety measures. MN05401010E italiano 1.3 Use according to the intended purpose c1.Hold the left key pressed and press the right key to exit the programming operation. c2. Press the right key to switch to . d. Hold the left key pressed and press the right key to switch to the first parameter. 1 7/31/12 e. After releasing the keys, the display alternates between the menu title and the current menu item setting. After pressing any key, only the menu item setting is displayed. f. Pressing the right key will switch the menu item setting to the next value. If figures are to be input (e.g. when setting the scaling factor), select first the decade using the left key, and then set the value using the right key. g. Hold the left key pressed and press the right key to switch to the next menu item. h. The last menu title “EndPro” allows the user, when selecting “Yes”, to exit the programming menu and to store the new values. If “no” is selected, the programming routine is repeated, the latest values set remaining active. They can now be checked again or modified. 3. Programming routine The first menu item is the selection of the basic operating mode, which determines the functions of the device. Operating mode adding counter and frequency meter, continued in point 4 below Operating mode display counter with 2 totalizing ranges, continued in point 4 on page 4 Operating mode totalizer and time meter, continued in point 4 on page 7 Operating mode time meter with 2 time ranges, continued in point 4 on page 9 2 9:10 AM Page 2 Electronic totalizer and frequency meter E5524E0402: basic operating mode 1. Description • 6-digit totalizer and frequency meter • Red LED display, character height 8 mm [0.31 in.] • Display range 0 – 999 999 • Lead zero blanking • Programming via two setting keys on the front side • During programming, the display guides the user with text prompts • Value conversion and display in 1/s or 1/min 2. Inputs INP A Dynamic count/frequency input. RESET Dynamic RESET input. Linked in parallel to the red RESET key. Resets the counter to zero. 3. Selection of the displayed value Pressing the right key allows switching between the totalizer display and the frequency meter display. Press the key briefly to display the current function (“total” or “tacho”) for 2 seconds. If, during this period of time, the right key is pressed a second time, the device switches to the next function and displays a confirmation (“total” or “tacho”) for 2 seconds. Then, the value of the selected function is displayed. 4. Programming routine The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factory settings. MN05401010E - Subject to change without prior notice - MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarity of the inputs npn: sinking sensor 9:10 AM Page 3 4.6 RESET mode (totalizer) english MN05401010E.qxd:MN05401010E manual reset via the red RESET key and electrical reset via the RESET input pnp: sourcing sensor 4.2 Switching on the 30 Hz filter (INP A) The filter provides input damping* no reset (red RESET key and RESET input locked) only electrical reset via the RESET input 30 Hz filter off (fmax) 30 Hz filter on 4.3 Multiplying factor (totalizer) It can be set from 00.0001 up to 99.9999. “0” is not accepted! only manual reset via the red RESET key 4.7 Multiplying factor (frequency meter) It can be set from 00.0001 up to 99.9999. “0” is not accepted! 4.4 Dividing factor ( totalizer) 4.8 Dividing factor (frequency meter) It can be set from 00.0001 up to 99.9999. “0” is not accepted! It can be set from 00.0001 up to 99.9999. “0” is not accepted! 4.5 Decimal point (totalizer) The decimal point defines the way of displaying the count values. It does not affect counting. 0 no decimal place 0.0 one decimal place 0.00 two decimal places 0.000 three decimal places * where bounce occurs, e.g. with contacts MN05401010E 4.9 Decimal point (frequency meter) The decimal point defines the resolution in the selected measuring range 1/min or 1/sec 0 no decimal place 0.0 one decimal place 0.00 two decimal places 0.000 three decimal places 3 MN05401010E.qxd:MN05401010E 7/31/12 4.10 Display mode (frequency meter) Value conversion and display in 1/s Value conversion and display in 1/min 4.11 Max. time to wait until “0” is displayed (frequency meter) This parameter indicates, how long it takes, when measuring is active, until “0” is displayed. Max. time to wait 00.1 s (min. value) Max. time to wait 99.9 s 4.12 End of programming The programming routine is repeated once more. The values set until now can be checked and modified. The programming routine will be exited and all values set will be stored as new parameters. Afterwards the device is ready for operation. 9:10 AM Page 4 Electronic display counter with 2 totalizing ranges E5524E0402: basic operating mode 1. Description • 6-digit display counter with Reset function • Red LED display, character height 8 mm [0.31 in.] • Display range 0 – 999 999 • Lead zero blanking • Programming via two setting keys on the front side • During programming, the display guides the user with text prompts 2. Inputs INP A Dynamic count input Counter 1 and Counter 2. RESET Dynamic RESET input. Linked in parallel to the red RESET key. Sets the counter to zero. Can be adjusted individually for Counter 1 and Counter 2. 3. Selection of the displayed value Pressing the right key allows switching between the display of totalizer 1 and the display of totalizer 2. Press the key briefly to display the current function (“total1” or “total2”) for 2 seconds. If, during this period of time, the right key is pressed a second time, the device switches to the next function and displays a confirmation (“total1” or “total2”) for 2 seconds. Then, the value of the selected function is displayed. 4. Programming routine The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factory settings. 4 MN05401010E 7/31/12 4.1 Polarity of the inputs npn: sinking sensor pnp: sourcing sensor 4.2 Switching on the 30 Hz filter (INP A) The filter provides input damping* 9:10 AM Page 5 4.6 RESET mode (totalizer 1) english MN05401010E.qxd:MN05401010E manual reset via the red RESET key and electrical reset via the RESET input no reset (red RESET key and RESET input locked) 30 Hz filter off (fmax) only electrical reset via the RESET input 30 Hz filter on only manual reset via the red RESET key 4.3 Multiplying factor It can be set from 00.0001 up to 99.9999. “0” is not accepted! 4.4 Dividing factor It can be set from 00.0001 up to 99.9999. “0” is not accepted! 4.7 RESET mode (totalizer 2) manual reset via the red RESET key and electrical reset via the RESET input no reset (red RESET key and RESET input locked) only electrical reset via the RESET input only manual reset via the red RESET key 4.5 Decimal point The decimal point defines the way of displaying the count values. It does not affect counting. 0 no decimal place 0.0 one decimal place 0.00 two decimal places 0.000 three decimal places * where bounce occurs, e.g. with contacts MN05401010E 5 MN05401010E.qxd:MN05401010E 7/31/12 4.8 End of programming 9:10 AM Page 6 Electronic totalizer and time meter E5524E0402: basic operating mode The programming routine is repeated once more. The values set until now can be checked and modified. The programming routine will be exited and all values set will be stored as new parameters. Afterwards the device is ready for operation. 1. Description • 6 digit totalizer and time meter with Reset function • Red LED display, character height 8 mm [0.31 in.] • Display range 0 – 999 999 • Lead zero blanking • Programming via two setting keys on the front side • During programming, the display guides the user with text prompts • Operation indicator: the decimal point of the lowest digit blinks while the count is active. • Time meter operating modes: – Counting while INP B is inactive “GAtE.Lo” – Counting while INP B is active “GAtE.hi” – Count Start/Stop with INP B edge B “Inb.Inb” • Counting ranges: h; min; s; h.min.s 2. Inputs INP A Dynamic count input for the totalizer. INP B Start-/Stop or gate input for time meter (independent of the input mode) RESET Dynamic RESET input. Linked in parallel to the red RESET key. Sets the counter to zero. Can be adjusted individually for the totalizer and the time meter. 3. Selection of the displayed value Pressing the right key allows switching between the totalizer display and the time meter display. Press the key briefly to display the current function (“total” or “time”) for 2 seconds. If, during this period of time, the right key is pressed a second time, the device switches to the next function and displays a confirmation (“total” or “time”) for 2 seconds. Then, the value of the selected function is displayed. 6 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4. Programming routine 9:10 AM Page 7 4.5 Decimal point (totalizer) The decimal point defines the way of displaying the count values. It does not affect counting. The first values stated correspond to the factory settings. 0 no decimal place 0.0 one decimal place 0.00 two decimal places 0.000 three decimal places 4.1 Polarity of the inputs english The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. 4.6 RESET mode (totalizer) npn: sinking sensor pnp: sourcing sensor 4.2 Switching on the 30 Hz filter (INP A, INP B) The filter provides input damping* 30 Hz filter off (fmax) Count and start/stop inputs not damped 30 Hz filter on Count and start/stop inputs damped 4.3 Multiplying factor (totalizer) It can be set from 00.0001 up to 99.9999. “0” is not accepted! 4.4 Dividing factor (totalizer) It can be set from 00.0001 up to 99.9999. “0” is not accepted! manual reset via the red RESET key and electrical reset via the RESET input no reset (red RESET key and RESET input locked) only electrical reset via the RESET input only manual reset via the red RESET key 4.7 Input mode (time meter) Start/Stop via Inp B. Timing while Inp B (Gate) not active or open Start/Stop via Inp B. Timing while Inp B (Gate) active (High level with pnp; Low level with npn) Time Start/Stop via INP B (LOW-HIGH edge with pnp; HIGH-LOW edge with npn). Every active edge changes the timer status. * where bounce occurs, e.g. with contacts MN05401010E 7 MN05401010E.qxd:MN05401010E 7/31/12 4.8 Operating mode (time meter) Time unit: seconds (resolution depending on position of the decimal point*) 9:10 AM Page 8 4.10 RESET mode (time meter) manual reset via the red RESET key and electrical reset via the RESET input Time unit: minutes (resolution depending on position of the decimal point*) no reset (red RESET key and RESET input locked) Time unit: hours (resolution depending on position of the decimal point*) only electrical reset via the RESET input Time units: Hours:Minutes:Seconds (decimal point setting is ignored) only manual reset via the red RESET key 4.11 End of programming *0, 0.1, 0.01, 0.001 means: time measurement in 0, 0.1, 0.01, 0.001 time units 4.9 Decimal point (time meter) The decimal point defines the resolution of the programmed time unit. 0 1 0.0 1/10 (0.1) 0.00 1/100 (0.01) 0.000 1/1000 (0.001) The programming routine is repeated once more. The values set until now can be checked and modified. The programming routine will be exited and all values set will be stored as new parameters. Afterwards the device is ready for operation. 8 MN05401010E 7/31/12 Electronic time meter with 2 time ranges E5524E0402: basic operating mode 1. Description • 6 digit time meter with Reset function • Red LED display, character height 8 mm [0.31 in.] • Display range 0 – 999 999 • Lead zero blanking • Programming via two setting keys on the front side • During programming, the display guides the user with text prompts • Operation indicator: the decimal point of the lowest digit blinks while the count is active • Time meter operating modes: – Timing while INP B is inactive “GAtE.Lo” – Timing while INP B is active “GAtE.hi” – Time Start/Stop with INP B edge (Inb.Inb) – Time Start with INP A edge, time Stop with INP B edge (InA.InB) 9:10 AM Page 9 4. Programming routine The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine. The first values stated correspond to the factory settings. 4.1 Polarity of the inputs npn: sinking sensor pnp: sourcing sensor 2. Inputs INP A Start input (depending on the input mode chosen) INP B Time meter Start/Stop or gate input (depending on the input mode chosen) RESET Dynamic RESET input. Linked in parallel to the red RESET key. Resets the timer to zero. Can be adjusted individually for Timer 1 and Timer 2. 3. Selection of the displayed value Pressing the right key allows switching between the display of time meter 1 and the display of time meter 2. Press the key briefly to display the current function (“time1” or “time2”) for 2 seconds. If, during this period of time, the right key is pressed a second time, the device switches to the next function and displays a confirmation (“time1” or “time2”) for 2 seconds. Then, the value of the selected function is displayed. 4.2 Switching on the 30 Hz filter (INP A, INP B) The filter provides input damping* 30 Hz filter off (fmax) Start/Stop inputs not damped 30 Hz filter on Start/Stop inputs damped for use with mechanical switches * where bounce occurs, e.g. with contacts MN05401010E 9 english MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.3 Input mode (time meter) Start/Stop via Inp B. Timing while Inp B (Gate) not active or open Start/Stop via Inp B. Timing while Inp B (Gate) active (High level with pnp; Low level with npn) Time Start/Stop via INP B (LOW-HIGH edge with pnp; HIGH-LOW edge with npn). Every active edge changes the timer status. Time start via INP A, stop via INP B. (LOW-HIGH edge with pnp; HIGHLOW edge with npn) 9:10 AM Page 10 4.5 Decimal point The decimal point defines the resolution of the programmed time unit. 0 1 0.0 1/10 (0.1) 0.00 1/100 (0.01) 0.000 1/1000 (0.001) 4.6 RESET mode (time meter 1) manual reset via the red RESET key and electrical reset via the RESET input no reset (red RESET key and RESET input locked) only electrical reset via the RESET input only manual reset via the red RESET key 4.4 Operating mode 4.7 RESET mode (time meter 2) Time unit: seconds (resolution depending on position of the decimal point*) Time unit: minutes (resolution depending on position of the decimal point*) Time unit: hours (resolution depending on position of the decimal point*) Time units: Hours:Minutes:Seconds (decimal point setting is ignored) *0, 0.1, 0.01, 0.001 means: time measurement in 0, 0.1, 0.01, 0.001 time units 10 manual reset via the red RESET key and electrical reset via the RESET input no reset (red RESET key and RESET input locked) only electrical reset via the RESET input only manual reset via the red RESET key MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Page 11 Frequency measurement: Error: < 0.1 % The programming routine is repeated once more. The values set until now can be checked and modified. The programming routine wil be exited and all values set will be stored as new parameters. Afterwards the device is ready for operation. 5. Technical data Supply voltage Measuring principle: < 38 Hz: period measurement > 38 Hz: gating time measurement gating time = 26.3 ms Time ranges: Seconds Minutes Hours h.min.s Error english 4.8 End of programming 9:10 AM 0.001 s – 999 999 s 0.001min – 999 999 min 0.001 h – 999 999 h 00 h 00 min 01 s – 99 h 59 min 59 s <50 ppm Minimum pulse length for the Reset input: 5 ms Input sensitivity: Standard sensitivity: Low: 0 – 0.2 x UB [V DC] High: 0.6 x UB – 30 [V DC] UB = Supply Voltage Power supply: 10 – 30V DC/max. 40 mA with inverse-polarity protection 5V sensitivity: Display: 6 digits, red 7 segment LED display, height 8 mm [0.31 in.] Low: 0 – 2V DC High: 4 – 30V DC Pulse shape: any, Schmitt-Trigger inputs EEPROM Ambient temperature: –20 ... +65°C at 10 ... 26 V DC –20 ... +55°C at >26 ... 30 V DC Data retention: Polarity of the inputs: Programmable, npn or pnp (sinking or sourcing) for all inputs Input resistance: appr. 5 kΩ Count frequency: DC power supply: Input level: typ. low level: typ. high level: Fmax: tot.tac tot.tot tot.ti1) tot.ti2) 24V 12V Standard 2.5V 2.0V 22.0V 10V kHz kHz 35 20 60 20 40 20 15 10 10 – 30V 5V 1.0V 4.0V kHz 8 8 8 8 1) Start Gate.Lo Inp B not active 2) Start InpB.InpB and Inp B connected with Inp A * at maximum frequency square wave pulses 1:1 MN05401010E Storage temperature: –25 to +70°C [-9 to 158°F] EMC: In compliance with the EC Directive 2004/108/EEC Noise emission EN 61 000-6-3/ EN 55 011 Class B Noise immunity EN 61 000-6-2 Housing: For front panel mounting: 48 x 24 mm [3.78 x 1.89 in.] acc. to DIN 43700, RAL7021, dark grey Weight: appr. 50 g [5.29 oz.] Front panel rating: IP 65 Cleaning: The front of the unit is to be cleaned only with a soft cloth moistened with water. 11 MN05401010E.qxd:MN05401010E 7/31/12 6. Terminal assignment 1 2 3 4 5 9:10 AM Page 12 7. Contents: 1 Digital display 1 Panel mounting clip 1 Bezel for screw mounting, panel cut out 50 x 25 mm [1.97 x 0.98 in.] 1 Bezel for clip mounting, panel cut out 50 x 25 mm [1.97 x 0.98 in.] 1 Seal 1 Multilingual operating instructions 10 – 30V DC 0 V GND INP A INP B Reset 8. Dimensions in mm [in.]: max. 19.3 [0.76] 24 [0.94] 22 x 5 [0.87 x 1.77] 48 [1.89] Panel cut out: 22.2+0.3 x 45+0.6 [0.87+0.01 x 1.77+0.02] 4 [0.16] 6.5 [0.26] 59 [2.32] Front bezel Panel cut out: 53 [2.09] 25 + 0.5 [0.98 + 0.02] 26 [1.10] 25 x 50 [0.98 x 1.97] 50 + 0.6 [1.97 + 0.02] 1 [0.04] 4 [0.16] 56 [2.20] 1 12 1 [0.04] 4 [0.16] 32 ± 0.01 [1.26 ± 0.004] 25 [0.98] 25 x 50 [0.98 x 1.97] 32 [ 1.26] 40 [1.57] 50 [1.97] M3 1 Counter sinking Af3, DIN 74 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 13 Instrucciones de puesta en servicio Contador indicador electrónico E5524E0402 Utilizar este visualizador únicamente – de acuerdo con su función material – si se encuentra en perfecto estado técnico – respetando las instrucciones deutilización y las instrucciones generales de seguridad. ! 1.2 Instrucciones generales de seguridad 1. Antes de todo trabajo de instalación o mantenimiento, asegúrese de que la alimentación del visualizador digital está cortada. 2. Utilizar este visualizador únicamente de acuerdo con su función material: Si se encuentra en perfecto estado técnico. Respetando las instrucciones de utilización y las instrucciones generales de seguridad. 3. Cumplir las normativas correspondientes al país y al usuario. 4. Este visualizador digital no debe utilizarse en zonas que presenten riesgo de explosión y en entornos de uso excluidos de la norma EN 61 010 Parte 1. 5. Este aparato sólo debe funcionar encajado, según la normativa profesiona, conforme a lo indicado en el capítulo “Características técnicas generales”. 1.3 Utilización correcta Este visualizador digital sólo puede utilizarse encajado. La aplicación de este producto respecta a procesos industriales y de control, en cadenas de fabricación de industrias del metal, madera, materias plásticas, papel, vidrio, textiles, etc. Las sobretensiones en los bornes del aparato deben limitarse a los valores de la categoría de sobretensión II. Si se implanta el visualizador digital para la vigilancia de máquinas o procesos en los que puede aparecer un riesgo de daños a la máquina o accidentes para los operarios en caso de avería o de un error de manipulación del aparato, usted tiene la obligación de adoptar medidas de seguridad apropiadas. MN05401010E 1.4 Descripción Las prestaciones del E5524E0402 hacen de él un aparato universal. En función del modo de funcionamiento seleccionado, se comporta como • un totalizador y frecuencímetro electrónico (véase página 14) • un contador indicador electrónico con 2 intervalos de totalización (véase página 16) • un totalizador y contador de tiempo electrónico (véase página 18) • un contador de tiempo electrónico con 2 contadores de tiempo (véase página 21) 2. Ajuste de los parámetros de funcionamiento a. Pulsar las dos teclas de la cara delantera y encender el aparato, o, con el aparato encendido, pulsar las dos teclas durante 5 s. b. En la pantalla aparece el mensaje c. Cuando se dejan de pulsar las teclas, la pantalla indica . c1. Mantener pulsada la tecla de la izquierda, luego pulsar la tecla de la derecha para interrumpir la operación de programación. c2. Pulsar la tecla de la derecha para que la pantalla indique . d. Mantener pulsada la teclada de la izquierda, luego pulsar la tecla de la derecha, para invocar el primer parámetro 13 español 1.1 Instrucciones de seguridad y advertencias 7/31/12 e. Cuando se dejan de pulsar las teclas aparecen, en intervalos de un segundo, el título del menú y el ajuste actual del punto del menú. Pulsar una tecla: la pantalla deja de alternar y sólo indica el ajuste del punto del menú. f. Durante el ajuste, si se pulsa una vez la tecla de la derecha se pasa al valor siguiente del parámetro. Para introducir valores numéricos (p. ej., al ajustar el factor), seleccionar primero la década con la tecla de la izquierda, luego ajustar su valor con la tecla de la derecha. g. Para pasar al siguiente punto del menú, mantener pulsada la tecla de la izquierda y pulsar la tecla de la derecha. h. El último punto del menú, “EndPro”, permite, si se selecciona “Yes”, salir del menú de programación y asumir (almacenar en memoria) los nuevos valores. Si se selecciona “no”, la programación vuelve a comenzar después del inicio, conservando los últimos valores introducidos. En ese caso es posible comprobarlos o modificarlos de nuevo. 9:10 AM Page 14 Totalizador y frecuencímetro electrónico E5524E0402: Modo de funcionamiento 1. Descripción • Contador totalizador y frecuencímetro con 6 décadas • Pantalla de LED rojos, altura 8 mm • Intervalo de visualización 0 ... 999 999 • Supresión de los ceros en cabeza • Programación con dos teclas de la cara delantera • Programación guiada por mensajes en la pantalla • Conversión y visualización del valor en 1/s o 1/min 2. Entradas 3. Rutina de programación INP A Entrada de conteo/de frecuencia dinámica. RESET Entrada RESET dinámica conectada en paralelo con la tecla RESET roja. Pone el contador a cero. El primer punto del menú es la selección del modo de funcionamiento básico. Éste determina las funciones del aparato. 3. Selección del valor visualizado Modo contador totalizador y frecuencímetro, véase pár. 4 en página 14 Modo contador indicador con 2 intervalos de totalización, véase pár. 4 en página 16 Pulsar la tecla de la derecha para cambiar entre la pantalla del totalizador y la del frecuencímetro. Si se pulsa una vez se visualiza durante 2 s la función corriente (“total” o “tacho”). Si se pulsa la tecla de la derecha de nuevo durante ese lapso de tiempo, la pantalla pasa a la función actual, y se visualiza (“total” o “tacho”) durante 2 s. para confirmación. A continuación aparece el valor de la función seleccionada. 4. Rutina de programación Modo contador totalizador y contador de tiempo, véase pár. 4 en página 19 Modo contador de tiempo con 2 intervalos de tiempo, véase pár. 4 en página 21 14 Los parámetros ajustables del dispositivo se indican abajo por su orden de aparición en la pantalla. Por tanto, el aparato está totalmente programado después de un ciclo de programación. Los primeros valores indicados corresponden al ajuste de fábrica. MN05401010E - Sin perjuicio de modificaciones técnicas - MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 4.1 Polaridad de las entradas npn: conmutación a 0 V 7/31/12 9:10 AM Page 15 4.6 Modo RESET (totalizador) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET pnp: conmutación a +UB El filtro amortigua la entrada* Filtro 30 Hz desactivado (fmax) Filtro 30 Hz activado 4.3 Factor de multiplicación (totalizador) Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja 4.7 Factor de multiplicación (frecuencímetro) Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. 4.4 Factor de división (totalizador) 4.8 Factor de división (frecuencímetro) Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. 4.5 Ajuste del punto decimal (totalizador) El punto decimal determina la representación del valor de conteo. No tiene ningún efecto sobre el conteo. 0 0.0 0.00 0.000 sin decimales un decimal dos decimales tres decimales * en caso de rebotes; p. Ej. , con contactos MN05401010E 4.9 Ajuste del punto decimal (frecuencímetro) El punto decimal determina la resolución. 0 0.0 0.00 0.000 sin decimales un decimal dos decimales tres decimales 15 español 4.2 Activación del filtro 30 Hz (INP A) MN05401010E.qxd:MN05401010E 7/31/12 4.10 Modo de visualización (frecuencímetro) Conversión y visualización del valor en 1/s Conversión y visualización del valor en 1/min 4.11 Espera máxima (frecuencímetro) Este valor indica cuánto tiempo debe esperar el sistema a un impulso, cuando la medición está en marcha, antes de representar 0 en pantalla. Espera máxima 00.1 s (valor mínimo) 9:10 AM Page 16 Contador indicador electrónico con 2 intervalos de totalización E5524E0402: Modo de funcionamiento 1. Descripción • Contador indicador con 6 décadas y función Reset • Pantalla de LED rojos, altura 8 mm • Intervalo de visualización 0 ... 999 999 • Supresión de los ceros en cabeza • Programación con dos teclas de la cara delantera • Programación guiada por mensajes en la pantalla 2. Entradas Espera máxima 99,9 s (valor máximo) 4.12 Fin de la programación La rutina de programación se realiza otra vez. Los valores introducidos pueden comprobarse y modificarse. La rutina de programación se termina y los valores introducidos se tienen en cuenta como nuevos parámetros. El dispositivo queda entonces listo para funcionar. INP A Entrada de conteo dinámica Contador 1 y Contador 2. RESET Entrada RESET dinámica conectada en paralelo con la tecla RESET roja. Pone el contador a cero. Ajustable de forma separada para el Contador 1 y para el Contador 2. 3. Selección del valor visualizado Pulsar la tecla de la derecha para cambiar entre la pantalla del totalizador 1 y la del totalizador 2. Si se pulsa una vez se visualiza durante 2 s la función corriente (“total1” o “total2”). Si se pulsa la tecla de la derecha de nuevo durante ese lapso de tiempo, la pantalla pasa a la función actual, y se visualiza (“total1” o “total2”) durante 2 s. para confirmación. A continuación aparece el valor de la función seleccionada. 4. Rutina de programación Los parámetros ajustables del dispositivo se indican abajo por su orden de aparición en la pantalla. Por tanto, el aparato está totalmente programado después de un ciclo de programación. Los primeros valores indicados corresponden al ajuste de fábrica. 16 MN05401010E MN05401010E.qxd:MN05401010E 4.1 Polaridad de las entradas npn: conmutación a 0 V 7/31/12 9:10 AM Page 17 4.6 Modo RESET (totalizador 1) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET pnp: conmutación a +UB El filtro amortigua la entrada* Filtro 30 Hz desactivado (fmax) Filtro 30 Hz activado No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja 4.3 Factor de multiplicación Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. 4.7 Modo RESET (totalizador 2) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET 4.4 Factor de división Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja 4.5 Ajuste del punto decimal El punto decimal determina la representación del valor de conteo. No tiene ningún efecto sobre el conteo. 0 0.0 0.00 0.000 sin decimales un decimal dos decimales tres decimales * en caso de rebotes; p. Ej. , con contactos MN05401010E 17 español 4.2 Activación del filtro 30 Hz (INP A) MN05401010E.qxd:MN05401010E 7/31/12 4.8 Fin de la programación 9:10 AM Page 18 Totalizador y contador de tiempo electrónico E5524E0402: Modo de funcionamiento La rutina de programación se realiza otra vez. Los valores introducidos pueden comprobarse y modificarse. La rutina de programación se termina y los valores introducidos se tienen en cuenta como nuevos parámetros. El dispositivo queda entonces listo para funcionar. 1. Descripción • Totalizador y contador de tiempo con 6 décadas y función Reset • Pantalla de LED rojos, altura 8 mm • Intervalo de visualización 0 ... 999 999 • Supresión de los ceros en cabeza • Programación con dos teclas de la cara delantera • Programación guiada por mensajes en la pantalla • Indicación de funcionamiento: el punto decimal de la década más baja parpadea cuando la medición del tiempo está activa • Modos de medición del tiempo: – Medición si INP B no está activado “GAtE.Lo” – Medición si INP B está activado “GAtE.hi” – Inicio/parada de medición por el frente INP B “Inb.Inb” • Intervalos de medición de tiempo: h; min; s; h.min.s 2. Entradas INP A Entrada de conteo dinámica para el totalizador. INP B Entrada inicio/parada o entrada puerta para el contador de tiempo (en función del tipo de entrada) RESET Entrada RESET dinámica conectada en paralelo con la tecla RESET roja. Pone el contador a cero. Ajustable de forma separada para el totalizador y para el contador de tiempo. 3. Selección del valor visualizado Pulsar la tecla de la derecha para cambiar entre la pantalla del totalizador y la del contador de tiempo. Si se pulsa una vez se visualiza durante 2 s la función corriente (“total” o “time”). Si se pulsa la tecla de la derecha de nuevo durante ese lapso de tiempo, la pantalla pasa a la función actual, y se visualiza (“total” o “time”) durante 2 s. para confirmación. A continuación 18 MN05401010E 7/31/12 aparece el valor de la función seleccionada. 4. Rutina de programación Los parámetros ajustables del dispositivo se indican abajo por su orden de aparición en la pantalla. Por tanto, el aparato está totalmente programado después de un ciclo de programación. Los primeros valores indicados corresponden al 4.1 Polaridad de las entradas 9:10 AM Page 19 4.5 Ajuste del punto decimal (totalizador) El punto decimal determina la representación del valor de conteo. No tiene ningún efecto sobre el conteo. 0 0.0 0.00 0.000 sin decimales un decimal dos decimales tres decimales español MN05401010E.qxd:MN05401010E 4.6 Modo RESET (totalizador) npn: conmutación a 0 V pnp: conmutación a +UB Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET 4.2 Activación del filtro 30 Hz (INP A, INP B) El filtro amortigua la entrada* No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Filtro 30 Hz desactivado (fmax) Entradas de conteo y de inicio/ parada no amortiguadas Puesta a cero eléctrica sólo por la entrada RESET Filtro 30 Hz activado Entradas de conteo y de inicio/parada amortiguadas Puesta a cero manual sólo por la tecla RESET roja 4.3 Factor de multiplicación (totalizador) 4.7 Tipo de entrada (contador de tiempo) Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. 4.4 Factor de división (totalizador) Factor ajustable de 00.0001 a 99.9999. El ajuste a “0” no se acepta. * en caso de rebotes; p. Ej. , con contactos MN05401010E Inicio/Parada por Inp B. Medición si Inp B (puerta) no está activo o está abierto Inicio/Parada por Inp B. Medición si Inp B (puerta) está activo (nivel alto para pnp; nivel bajo para npn) Medición puesta en marcha y parada por INP B (frente de impulso ascendente para pnp; frente de impulso descendente para npn). Cada frente activo modifica el estado de conteo. 19 MN05401010E.qxd:MN05401010E 7/31/12 4.8 Modo de funcionamiento (contador de tiempo) Unidad de tiempo: segundos (el ajuste del punto decimal determina la resolución*) Unidad de tiempo: minutos (el ajuste del punto decimal determina la resolución*) Unidad de tiempo: horas (el ajuste del punto decimal determina la resolución*) Unidad de conteo: Horas:Minutos:Segundos (el ajuste del punto decimal no se tiene en cuenta) *0, 0.1, 0.01, 0.001 significa: medición del tiempo en 0, 0,1, 0,01, 0,001 unidades de tiempo 4.9 Ajuste del punto decimal (contador de tiempo) El punto decimal determina la resolución de la unidad de tiempo programada. 0 0.0 0.00 0.000 20 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 9:10 AM Page 20 4.10 Modo RESET (contador de tiempo) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja 4.11 Fin de la programación La rutina de programación se realiza otra vez. Los valores introducidos pueden comprobarse y modificarse. La rutina de programación se termina y los valores introducidos se tienen en cuenta como nuevos parámetros. El dispositivo queda entonces listo para funcionar. MN05401010E 7/31/12 Contador de tiempo electrónico con 2 contadores E5524E0402: Modo de funcionamiento 1. Descripción • Contador de tiempo con 6 décadas y función Reset • Pantalla de LED rojos, altura 8 mm • Intervalo de visualización 0 ... 999 999 • Supresión de los ceros en cabeza • Programación con dos teclas de la cara delantera • Programación guiada por mensajes en la pantalla • Indicación de funcionamiento: el punto decimal de la década más baja parpadea cuando la medición del tiempo está activa • Modos de medición del tiempo: – Medición si INP B no está activado “GAtE.Lo” – Medición si INP B está activado “GAtE.hi” – Inicio/parada de medición por el frente INP B “Inb.Inb” – Inicio de medición por el frente Inp A, parada de medición por el frente INP B (InA.InB) • Intervalos de medición de tiempo: h; min; s; h.min.s 2. Entradas INP A Entrada de inicio (en función del tipo de entrada) INP B Entrada inicio/parada o entrada puerta para el contador de tiempo (en función del tipo de entrada) RESET Entrada RESET dinámica conectada en paralelo con la tecla RESET roja. Pone el contador en cero. Ajustable separadamente para el Contador 1 y para el Contador 2. 3. Selección del valor visualizado Pulsar la tecla de la derecha para cambiar entre la pantalla del contador de tiempo 1 y la del contador de tiempo 2. Si se pulsa una vez se visualiza durante 2 s la función corriente (“time1” o “time2”). Si se pulsa la tecla de la derecha de nuevo durante ese lapso de tiempo, la pantalla pasa a la función actual, y se visualiza (“time1” o “time2”) durante 2 s. para confirmación. A continuación aparece el valor de la función seleccionada. MN05401010E 9:10 AM Page 21 4. Rutina de programación Los parámetros ajustables del dispositivo se indican abajo por su orden de aparición en la pantalla. Por tanto, el aparato está totalmente programado después de un ciclo de programación. Los primeros valores indicados corresponden al ajuste de fábrica. español MN05401010E.qxd:MN05401010E 4.1 Polaridad de las entradas npn: conmutación a 0 V pnp: conmutación a +UB 4.2 Activación del filtro 30 Hz (INP A, INP B) El filtro amortigua la entrada* Filtro 30 Hz desactivado (fmax) Entrada de inicio/parada no amortiguada Filtro 30 Hz activado Amortiguación de las entradas de inicio/parada para un comando por contactos mecánicos * en caso de rebotes; p. Ej. , con contactos 21 MN05401010E.qxd:MN05401010E 7/31/12 4.3 Tipo de entrada (contador de tiempo) Inicio/Parada por Inp B. Medición si Inp B (puerta) no está activo o está abierto Inicio/Parada por Inp B. Medición si Inp B (puerta) está activo (nivel alto para pnp; nivel bajo para npn) Medición puesta en marcha y parada por INP B (frente de impulso ascendente para pnp; frente de impulso descendente para npn). Cada frente activo modifica el estado de conteo. Medición puesta en marcha por INP A, parada por INP B. (frente de impulso ascendente para pnp; frente de impulso descendente para npn) 4.4 Modo de funcionamiento Unidad de tiempo: segundos (el ajuste del punto decimal determina la resolución*) Unidad de tiempo: minutos (el ajuste del punto decimal determina la resolución*) Unidad de tiempo: horas (el ajuste del punto decimal determina la resolución*) Unidad de conteo: Horas:Minutos:Segundos (el ajuste del punto decimal no se tiene en cuenta) *0, 0.1, 0.01, 0.001 significa: medición del tiempo en 0, 0,1, 0,01, 0,001 unidades de tiempo 22 9:10 AM Page 22 4.5 Ajuste del punto decimal El punto decimal determina la resolución de la unidad de tiempo programada. 0 0.0 0.00 0.000 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 4.6 Modo RESET (contador de tiempo 1) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja 4.7 Modo RESET (contador de tiempo 2) Puesta a cero manual con la tecla RESET roja y eléctrica por la entrada RESET No hay puesta a cero (tecla RESET roja y entrada RESET desactivadas) Puesta a cero eléctrica sólo por la entrada RESET Puesta a cero manual sólo por la tecla RESET roja MN05401010E 7/31/12 4.8 Fin de la programación La rutina de programación se realiza otra vez. Los valores introducidos pueden comprobarse y modificarse. La rutina de programación se termina y los valores introducidos se tienen en cuenta como nuevos parámetros. El dispositivo queda entonces listo para funcionar. 5. Características técnicas Tensión de alimentación Alimentación: 10 ... 30 V CC/max. 50 mA con protección contra las inversiones de la polaridad Pantalla : Roja, 6 décadas, LED con 7 segmentos, altura 8 mm 9:10 AM Page 23 Medición de la frecuencia: Precisión: < 0,1 % Principio de medida: < 38 Hz: Medición de duración del periodo > 38 Hz: Medición de duración de accionamiento de puerta Medicióne de puerta 25,3 ms Intervalos de medición de tiempo: Segundos 0,001 s ... 999 999 s Minutos 0,001min ... 999 999 min Horas 0,001 h ... 999 999 h h.min.s 00 h 00 min 01 s ... 99 h 59 min 59 s Precisión <50 ppm español MN05401010E.qxd:MN05401010E Duración mínima de impulso en la entrada de puesta a cero: 5 ms Nivel de conmutación de las entradas: Nivel estándar: Low: 0 ... 0,2 x UB [V CC] High: 0,6 x UB ... 30 [V CC] UB = Suministro de voltaje Nivel 5V: Low: 0 ... 1 V CC High: 4 ...30 V CC Memorización de datos: EEPROM Forma de los impulsos*: cualquiera, entrada por disparador de Schmitt Polaridad de las entradas: Programable, npn o pnp para todas las entradas Temperatura ambiente: –20 ... +65 °C a 10 ... 26 V DC –20 ... +55 °C a >26 ... 30 V DC Resistencia de entrada: alrededor de 5 kΩ Frecuencias de conteo: Alimentación CC: 24 V 12 V Nivel: Standard typ. Low: 2,5 V 2,0 V typ. High: 22,0 V 10 V Fmax*: kHz kHz tot.tac 35 20 tot.tot 60 20 tot.ti1) 40 20 2) tot.ti 15 10 10 ... 30 V 5V 1,0 V 4,0 V kHz 8 8 8 8 * a máxima frecuencia impulsos de onda cuadrada 1:1 1) Start Gate.Lo Inp B no está activo 2) Start InpB.InpB e Inp B conectado con Inp A MN05401010E Temperatura de almacenamiento: –25 ... +70 °C CEM: Conforme con la directiva CE 2004/108/CEE Emisión de ruidos EN 61 000-6-3/ EN 55 011 Clase B Inmunidad a las ruidos EN 61 000-6-2 Caja: Para montaje en panel: 48 x 24 mm según DIN 43700, RAL7021, gris oscuro Peso: alrededor de 50 g Tipo de protección: IP 65 (cara delantera) Limpieza: Los frontales de los aparatos deben limpiarse exclusivamente con un paño suave húmedo. 23 MN05401010E.qxd:MN05401010E 6. 1 2 3 4 5 7/31/12 Conexiones 10 ... 30 V DC 0 V GND INP A INP B Reset 9:10 AM Page 24 7. El suministro incluye: 1 Indicador 1 Brida de fijación 1 Marco para fijación por brida, para recorte en panel 50 x 25 mm 1 Marco para fijación por tornillos, para recorte en panel 50 x 25 mm 1 Junta de estanqueidad 1 Manual de instrucciones multilingüe 8. Dimensiones: max. 19.3 [0.76] 24 [0.94] 22 x 5 [0.87 x 1.77] 48 [1.89] Corte en el panel: 22,2+0,3 x 45+0,6 mm 4 [0.16] 6.5 [0.26] 59 [2.32] Bisel delantero Corte en el panel: 53 [2.09] 25 + 0.5 [0.98 + 0.02] 26 [1.10] 25 x 50 [0.98 x 1.97] 50 + 0.6 [1.97 + 0.02] 1 [0.04] 4 [0.16] 56 [2.20] 1 24 1 [0.04] 4 [0.16] 32 ± 0.01 [1.26 ± 0.004] 25 [0.98] 25 x 50 [0.98 x 1.97] 32 [ 1.26] 40 [1.57] 50 [1.97] M3 1 Avellanado Af3, DIN 74 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 25 Notice de mise en service Compteur à affichage électronique E5524E0402 N’utiliser ces afficheurs que – de manière conforme à leur destination – s’ils sont techniquement en parfait état – en respectant les instructions d’utilisation et les instructions générales de sécurité. ! 1.2 Onstructions générales de sécurité 1. Avant tout travail d’installation ou de maintenance, s’assurer que l’alimentation de l’afficheur digital est coupée. 2. N’utiliser cet afficheur que de manière conforme à sa destination: Il doit être techniquement en parfait état. Respecter les instructions d’utilisation et les instructions générales de sécurité. 3. Tenir compte des réglementations spécifiques au pays et à l’utilisateur. 4. L’afficheur digital ne convient pas pour des zones présentant des risques d’explosion, ni dans les domaines d’utilisation exclus par la norme EN 61010 Partie 1. 5. L’afficheur digital ne doit être utilisé que s’il a été encastré dans les règles de l’art, conformément au chapitre “Caractéristiques techniques générales”. 1.4 Description L’exécution du E5524E0402 en fait un appareil universel. En fonction du mode de fonctionnement sélectionné, il se comporte comme • un totalisateur et fréquencemètre électronique (voir page 26) • un compteur à affichage électronique avec 2 plages de totalisation (voir page 28) • un totalisateur et compteur de temps électronique (voir page 30) • un compteur de temps électronique avec 2 compteurs de temps (voir page 33) 2. Réglage des paramètres de fonctionnement a. Presser les deux touches de la face avant et mettre l’appareil sous tension, ou, l’appareil étant sous tension, presser les deux touches pendant 5 s. b. Sur l’affichage apparaît le message c. Dès que les touches sont relâchées, l’affichage indique 1.3 Utilisation conforme L’afficheur digital ne peut être utilisé qu’en tant qu’appareil encastré. Ce produit trouve son application dans les process industriels et les commandes, dans le domaine des chaînes de fabrication des industries du métal, du bois, des matières plastiques, du papier, du verre, du textile, etc. Les surtensions aux bornes de l’afficheur digital doivent être limitées aux valeurs de la catégorie de surtension II. Si l’afficheur digital est mis en oeuvre pour la surveillance de machines ou de process où, en cas de panne ou d’une erreur de manipulation de l’appareil, peuvent apparaître des risques de dommages à la machine ou d’accidents pour les opérateurs, il vous appartient de prendre les mesures de sécurité appropriées. MN05401010E c1.Maintenir la touche de gauche pressée, puis presser la touche de droite, pour interrompre l’opération de programmation. c2. Presser la touche de droite pour que l’affichage indique . d. Maintenir la touche de gauche pressée, puis presser la touche de droite, pour appeler le premier paramètre. 25 français 1.1 Instructions de sécurité et avertissements 7/31/12 e. Dès relâchement des touches apparaît, par périodes d’une seconde, le titre du menu et sa programmation actuelle. Presser une touche : l’affichage cesse d’alterner et n’indique plus que le réglage du point du menu. f. Une impulsion sur la touche de droite permet de passer à la valeur suivante du paramètre en cours de réglage. Pour introduire des valeurs numériques (p. ex. lors du réglage du facteur), sélectionner d’abord la décade à l’aide de la touche de gauche, puis régler sa valeur à l’aide de la touche de droite. g. Pour passer au paramètre suivant du menu, maintenir la touche de gauche pressée et presser la touche de droite. h. Le dernier paramètre du menu, “EndPro”, permet, en sélectionnant “Yes”, de quitter le menu de programmation et de prendre en compte (sauvegarder) les nouvelles valeurs. Si “No” est sélectionné, la programmation recommence depuis le début, en conservant les dernières valeurs introduites. Il est alors possible de les vérifier ou de les modifier à nouveau. 9:10 AM Page 26 Totalisateur et fréquencemètre électronique E5524E0402 : Mode de fonctionnement 1. Description • Compteur totalisateur et fréquencemètre à 6 décades • Affichage par LED rouges, hauteur 8 mm • Plage d’affichage de 0 à 999 999 • Suppression des zéros de tête • Programmation par deux touches sur la face avant • Programmation guidée par des messages sur l’affichage • Conversion et affichage de la valeur en 1/s ou 1/min 2. Entrées INP A Entrée de comptage/de fréquence dynamique. RESET Entrée RESET dynamique couplée en parallèle avec la touche RESET rouge. Remet le compteur à zéro. 3. Routine de programmation Le premier point du menu est la sélection du mode de fonctionnement de base. Celui-ci détermine les fonctions de l’appareil. Mode compteur totalisateur et fréquencemètre, voir par. 4 en page 26 Mode compteur à affichage avec 2 plages de totalisation, voir par. 4 en page 28 Mode compteur totalisateur et compteur de temps, voir par. 4. en page 31 Mode compteur de temps avec 2 plages de temps, voir par. 4. en page 33 26 3. Sélection de la valeur affichée Presser la touche de droite pour commuter entre l’affichage du totalisateur et celui du fréquencemètre. Une impulsion unique affiche pendant 2 s. la fonction courante (“total” ou “tacho”). Si la touche de droite est pressée à nouveau pendant ce laps de temps, l’affichage passe à la fonction courante, et (“total” ou “tacho”) s’affiche pendant 2 s. pour confirmation. Ensuite, la valeur de la fonction sélectionnée s’affiche. 4. Routine de programmation Les paramètres réglables de l’appareil sont indiqués ci-dessous dans l’ordre de leur apparition sur l’affichage. L’appareil est donc entièrement programmé après un cycle de programmation. Les premières valeurs indiquées correspondent au réglage d’usine. MN05401010E - Sous réserve de modifications techniques - MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarité des entrées npn : commutation à 0 V pnp : commutation à +UB 4.2 Activation du filtre 30 Hz (INP A) 9:10 AM Page 27 4.6 Mode RESET (totalisateur) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Le filtre atténue l’entrée* Filtre 30 Hz désactivé (fmax) Remise à zéro électrique par l’entrée RESET uniquement Filtre 30 Hz activé Remise à zéro manuelle par la touche RESET rouge uniquement 4.3 Facteur de multiplication (totalisateur) Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. 4.7 Facteur de multiplication (fréquencemètre) Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté ! 4.4 Facteur de division (totalisateur) 4.8 Facteur de division (fréquencemètre) Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. 4.5 Réglage du point décimal (totalisateur) Le point décimal détermine la représentation de la valeur de comptage. Il n’a aucun effet sur le comptage. 0 pas de décimale 0.0 une décimale 0.00 deux décimales 0.000 trois décimales * rebonds, par ex. avec des contacts mécaniques MN05401010E Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté ! 4.9 Réglage du point décimal (fréquencemètre) Le point décimal détermine la résolution pour les bases de temps 1/min et 1/sec. 0 pas de décimale 0.0 une décimale 0.00 deux décimales 0.000 trois décimales 27 français MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.10 Mode d’affichage (fréquencemètre) Conversion et affichage de la valeur en 1/s Conversion et affichage de la valeur en 1/min 4.11 Attente maximale (fréquencemètre) Cette valeur indique combien de temps le système doit attendre une impulsion, la mesure étant en marche, avant d’afficher 0. Attente maximale 00.1 s (valeur minimum) Attente maximale 99,9 s (valeur maximum) 4.12 Fin de la programmation La programmation est exécutée encore une fois. Les valeurs introduites peuvent être vérifiées et modifiées. La programmation est terminée et les valeurs introduites sont prises en compte comme nouveaux paramètres. L’appareil est alors prêt à fonctionner. 9:10 AM Page 28 Compteur à affichage électronique avec 2 plages de totalisation E5524E0402 : Mode de fonctionnement 1. Description • Compteur à affichage à 6 décades avec fonction Reset • Affichage par LED rouges, hauteur 8 mm • Plage d’affichage de 0 à 999 999 • Suppression des zéros de tête • Programmation par deux touches sur la face avant • Programmation guidée par des messages sur l’affichage 2. Entrées INP A Entrée de comptage dynamique Compteur 1 er Compteur 2. RESET Entrée RESET dynamique couplée en parallèle avec la touche RESET rouge. Remet le compteur à zéro. Réglable séparément pour le Compteur 1 et le Compteur 2. 3. Sélection de la valeur affichée Presser la touche de droite pour commuter entre l’affichage du totalisateur 1 et celui du totalisateur 2. Une impulsion unique affiche pendant 2 s. la fonction courante (“total1” ou “total2”). Si la touche de droite est pressée à nouveau pendant ce laps de temps, l’affichage passe à la fonction courante, et (“total1” ou “total2”) s’affiche pendant 2 s. pour confirmation. Ensuite, la valeur de la fonction sélectionnée s’affiche. 4. Routine de programmation Les paramètres réglables de l’appareil sont indiqués ci-dessous dans l’ordre de leur apparition sur l’affichage. L’appareil est donc entièrement programmé après un cycle de programmation. Les premières valeurs affichées correspondent au réglage d’usine. 28 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarité des entrées npn : commutation à 0 V pnp : commutation à +UB 4.2 Activation du filtre 30 Hz(INP A) Le filtre atténue l’entrée* Filtre 30 Hz désactivé (fmax) Filtre 30 Hz activé 9:10 AM Page 29 4.6 Mode RESET (totalisateur 1) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Remise à zéro manuelle par la touche RESET rouge uniquement Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. 4.4 Facteur de division Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. 4.5 Réglage du point décimal Le point décimal détermine la représentation de la valeur de comptage. Il n’a aucun effet sur le comptage. français 4.3 Facteur de multiplication 4.7 Mode RESET (totalisateur 2) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Remise à zéro manuelle par la touche RESET rouge uniquement 0 pas de décimale 0.0 une décimale 0.00 deux décimales 0.000 trois décimales * rebonds, par ex. avec des contacts mécaniques MN05401010E 29 MN05401010E.qxd:MN05401010E 7/31/12 4.8 Fin de la programmation 9:10 AM Page 30 Totalisateur et compteur de temps électronique E5524E0402 : Mode de fonctionnement La programmation est exécutée encore une fois. Les valeurs introduites peuvent être vérifiées et modifiées. La programmation est terminée et les valeurs introduites sont prises en compte comme nouveaux paramètres. L’appareil est alors prêt à fonctionner. 1. Description • Totalisateur et compteur de temps à 6 décades avec fonction Reset • Affichage par LED rouges, hauteur 8 mm • Plage d’affichage de 0 à 999 999 • Suppression des zéros de tête • Programmation par deux touches sur la face avant • Programmation guidée par des messages sur l’affichage • Indication de fonctionnement : le point décimal de la décade la plus faible clignote lorsque la mesure de temps est active • Modes de mesure de temps : – Mesure de temps si INP B n’est pas activé “GAtE.Lo” – Mesure de temps si INP B est activé “GAtE.hi” – Marche/arrêt de la mesure de temps par le front INP B “Inb.Inb” • Plages de mesure de temps : h; min; s; h.min.s 2. Entrées INP A Entrée de comptage dynamique du totalisateur. INP B Entrée marche/arrêt ou porte du compteur de temps (en fonction du type d’entrée) RESET Entrée RESET dynamique couplée en parallèle avec la touche RESET rouge. Remet le compteur à zéro. Réglable séparément pour le totalisateur et pour le compteur de temps. 3. Sélection de la valeur affichée Presser la touche de droite pour commuter entre l’affichage du totalisateur et celui du compteur de temps. Une impulsion unique affiche pendant 2 s. la fonction courante (“total” ou “time”). Si la touche de droite est pressée à nouveau pendant ce laps de temps, l’affichage passe à la fonction courante, et (“total” ou“time”) s’affiche pendant 2 s. pour confirmation. Ensuite, la valeur de la fonction sélectionnée s’affiche. 30 MN05401010E 7/31/12 4. Routine de programmation 9:10 AM Page 31 4.5 Réglage du point décimal (totalisateur) Les paramètres réglables de l’appareil sont indiqués ci-dessous dans l’ordre de leur apparition sur l’affichage. L’appareil est donc entièrement programmé après un cycle de programmation. Le point décimal détermine la représentation de la valeur de comptage. Il n’a aucun effet sur le comptage. Les premières valeurs affichées correspondent au réglage d’usine. 0 pas de décimale 0.0 une décimale 0.00 deux décimales 0.000 trois décimales 4.1 Polarité des entrées npn : commutation à 0 V pnp : commutation à +UB 4.2 Activation du filtre 30 Hz (INP A, INP B) Le filtre atténue l’entrée* Filtre 30 Hz désactivé (fmax) Entrées de comptage et de marche/arrêt non amorties Filtre 30 Hz activé Entrées de comptage et de marche/arrêt amorties 4.6 Mode RESET (totalisateur) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Remise à zéro manuelle par la touche RESET rouge uniquement 4.7 Type d’entrée (compteur de temps) 4.3 Facteur de multiplication (totalisateur) Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. 4.4 Facteur de division (totalisateur) Facteur réglable de 00.0001 à 99.9999. Le réglage à “0” n’est pas accepté. * rebonds, par ex. avec des contacts mécaniques MN05401010E Marche/arrêt par Inp B. Mesure du temps si Inp B (porte) n’est pas actif ou est ouvert Marche/arrêt par Inp B. Mesure du temps si Inp B (porte) est actif (niveau haut pour pnp ; niveau bas pour npn) Mesure de temps mise en marche et arrêtée par INP B (front d’impulsion montant pour pnp ; front d’impulsion descendant pour npn). Chaque front actif modifie l’état du comptage. 31 français MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.8 Mode de fonctionnement (compteur de temps) Unité de temps : secondes (le réglage du point décimal détermine la résolution*) Unité de temps : minutes (le réglage du point décimal détermine la résolution*) Unité de temps : heures (le réglage du point décimal détermine la résolution*) Unité de comptage : Heures:Minutes:Secondes (le réglage du point décimal est ignoré) *0, 0.1, 0.01, 0.001 signifie : mesure du temps en 0, 0,1, 0,01, 0,001 unités de temps 4.9 Réglage du point décimal (compteur de temps) Le point décimal détermine la résolution de l’unité de temps programmée. 0 0.0 0.00 0.000 32 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 9:10 AM Page 32 4.10 Mode RESET (compteur de temps) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Remise à zéro manuelle par la touche RESET rouge uniquement 4.11 Fin de la programmation La programmation est exécutée encore une fois. Les valeurs introduites peuvent être vérifiées et modifiées. La programmation est terminée et les valeurs introduites sont prises en compte comme nouveaux paramètres. L’appareil est alors prêt à fonctionner. MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Compteur de temps électronique avec 2 compteurs E5524E0402 : Mode de fonctionnement 9:10 AM Page 33 4. Routine de programmation Les paramètres réglables de l’appareil sont indiqués ci-dessous dans l’ordre de leur apparition sur l’affichage. L’appareil est donc entièrement programmé après un cycle de programmation. 1. Description 2. Entrées INP A Entrée de “marche” (en fonction du type d’entrée) INP B Entrée marche/arrêt ou entrée porte pour le compteur de temps (en fonction du type d’entrée) RESET Entrée RESET dynamique couplée en parallèle avec la touche RESET rouge. Remet le compteur à zéro. Réglable séparément pour le Compteur 1 et pour le Compteur 2. Les premières valurs affichées correspondent au réglage d’usine. 4.1 Polarité des entrées npn : commutation à 0 V pnp : commutation à +UB 4.2 Activation du filtre 30 Hz (INP A, INP B) Le filtre atténue l’entrée* Filtre 30 Hz désactivé (fmax) Entrée de marche/arrêt non amortie Filtre 30 Hz activé Amortissement des entrées de marche/arrêt pour une commande par contacts mécaniques 3. Sélection de la valeur affichée Presser la touche de droite pour commuter entre l’affichage du compteur de temps 1 et celui du compteur de temps 2. Une impulsion unique affiche pendant 2 s. la fonction courante (“time1” ou “time2”). Si la touche de droite est pressée à nouveau pendant ce laps de temps, l’affichage passe à la fonction courante, et (“time1” ou “time2”) s’affiche pendant 2 s. pour confirmation. Ensuite, la valeur de la fonction sélectionnée s’affiche. MN05401010E * rebonds, par ex. avec des contacts mécaniques 33 français • Compteur de temps à 6 décades avec fonction Reset • Affichage par LED rouges, hauteur 8 mm • Plage d’affichage de 0 à 999 999 • Suppression des zéros de tête • Programmation par deux touches sur la face avant • Programmation guidée par des messages sur l’affichage • Indication de fonctionnement : le point décimal de la décade la plus faible clignote lorsque la mesure de temps est active • Modes de mesure de temps : – Mesure de temps si INP B n’est pas activé “GAtE.Lo” – Mesure de temps si INP B est activé “GAtE.hi” – Marche/arrêt de la mesure de temps par le front INP B “Inb.Inb” – Marche de la mesure par le front Inp A, arrêt de la mesure par le front INP B (InA.InB) • Plages de mesure de temps : h; min; s; h.min.s MN05401010E.qxd:MN05401010E 7/31/12 4.3 Type d’entrée (compteur de temps) Marche/arrêt par Inp B. Mesure du temps si Inp B (porte) n’est pas actif ou est ouvert Marche/arrêt par Inp B. Mesure du temps si Inp B (porte) est actif (niveau haut pour pnp ; niveau bas pour npn) Mesure de temps mise en marche et arrêtée par INP B (front d’impulsion montant pour pnp ; front d’impulsion descendant pour npn). Chaque front actif modifie l’état du comptage. Mesure de temps mise en marche par INP A, arrêtée par INP B. (front d’impulsion montant pour pnp ; front d’impulsion descendant pour npn) 4.4 Mode de fonctionnement 9:10 AM Page 34 4.5 Réglage du point décimal Le point décimal détermine la résolution de l’unité de temps programmée. 0 0.0 0.00 0.000 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 4.6 Mode RESET (compteur de temps 1) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Remise à zéro manuelle par la touche RESET rouge uniquement 4.7 Mode RESET (compteur de temps 2) Unité de temps : secondes (le réglage du point décimal détermine la résolution*) Unité de temps : minutes (le réglage du point décimal détermine la résolution*) Unité de temps : heures (le réglage du point décimal détermine la résolution*) Remise à zéro manuelle par la touche RESET rouge et électrique par l’entrée RESET Pas de remise à zéro (touche RESET rouge et entrée RESET désactivées) Remise à zéro électrique par l’entrée RESET uniquement Unité de comptage : *0, 0.1, 0.01, 0.001 signifie : mesure du temps en 0, 0,1, 0,01, 0,001 unités de temps 34 Remise à zéro manuelle par la touche RESET rouge uniquement MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Mesure de fréquence : Précision : < 0,1 % La programmation est exécutée encore une fois. Les valeurs introduites peuvent être vérifiées et modifiées. Principe de mesure : Mesure de durée de période < 38 Hz: > 38 Hz: Mesure de durée de portillonnage durée de potillonage = 23,6 ms La programmation est terminée et les valeurs introduites sont prises en compte comme nouveaux paramètres. Plages de mesure du temps : Secondes 0,001 s ... 999 999 s Minutes 0,001min ... 999 999 min Heures 0,001 h ... 999 999 h h.min.s 00 h 00 min 01 s ... 99 h 59 min 59 s Précision <50 ppm L’appareil est alors prêt à fonctionner. 5. Caractéristiques techniques Tension d’alimentation Alimentation : 10 ... 30 V CC/max. 40 mA avec protection contre les inversions de polarité Affichage : Rouge, 6 décades LED à 7 segments, hauteur 8 mm Mémorisation des données : EEPROM Polarité des entrées: Programmable, npn ou pnp pour toutes les entrées Résistance d’entrée : env. 5 kΩ Alimentation CC: 24 V 12 V Niveau: Standard typ. low: 2,5 V 2,0 V typ. ligh: 22,0 V 10 V Fmax*: kHz kHz tot.tac 35 20 tot.tot 60 20 tot.ti1) 40 20 tot.ti2) 15 10 Durée minimale de l’impulsion sur l’entrée de remise à zéro : 5 ms Niveau de commutation des entrées : Niveau standard : Low: 0 ... 0,2 x UB [V CC] High: 0,6 x UB ... 30 [V CC] UB = Tension d’alimentation Niveau 5 V : Low: 0 ... 2 V CC High: 4 ...30 V CC Fome des impulsions : quelconque*, entrée par trigger de Schmitt Température ambiante : –20 ... +65 °C avec 10 ... 26 V DC –20 ... +55 °C avec >26 ... 30 V DC Température de stockage : –25 ... +70 °C Fréquences de comptage : 10 ... 30 V 5V 1,0 V 4,0 V kHz 8 8 8 8 *signaux rectangulaires, rapport impulsion/pause 1:1 1) Start Gate.Lo Inp B non actif 2) Start InpB.InpB et Inp B connexe avec Inp A MN05401010E Page 35 CEM : Conforme à la directive CE 2004/108/CEE Emission de parasites EN 61 000-6-3/ EN 55 011 Classe B Immunité aux parasites EN 61 000-6-2 Boîtier : Pour montage dans panneau : 48 x 24 mm selon DIN 43700, RAL7021, gris foncé Poids : env. 50 g Indice de protection : IP 65 (face avant) Nettoyage: Les faces avant des appareils ne doivent être nettoyées qu’avec un chiffon doux humide. 35 français 4.8 Fin de la programmation 9:10 AM MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 36 6. Raccordements 7. La livraison comprend : 1 2 3 4 5 1 Afficheur 1 Bride de fixation 1 Cadre pour fixation par bride, pour découpe d’encastrement 50 x 25 mm 1 Cadre pour fixation par vis, pour découpe d’encastrement 50 x 25 mm 1 Joint 1 Notice d´utilisation multilingue 10 ... 30 V DC 0 V GND INP A INP B Reset 8. Dimensions : max. 19.3 [0.76] 22 x 5 [0.87 x 1.77] 24 [0.94] 48 [1.89] Découpe d´encastrement : 22,2+0,3 x 45+0,6 mm 4 [0.16] 6.5 [0.26] 59 [2.32] Facade encastrable Découpe d´encastrement : 53 [2.09] 25 + 0.5 [0.98 + 0.02] 26 [1.10] 25 x 50 [0.98 x 1.97] 50 + 0.6 [1.97 + 0.02] 1 [0.04] 4 [0.16] 56 [2.20] 1 36 1 [0.04] 4 [0.16] 32 ± 0.01 [1.26 ± 0.004] 25 [0.98] 25 x 50 [0.98 x 1.97] 32 [ 1.26] 40 [1.57] 50 [1.97] M3 1 Fraisure Af3, DIN 74 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 37 Bedienungsanleitung Elektronische Anzeigezähler E5524E0402 1.1 Sicherheits- und Warnhinweise 1.4 Beschreibung Benutzen Sie diese Anzeige nur – bestimmungsgemäß – in technisch einwandfreiem Zustand – unter Beachtung der Bedienungsanleitung und den allgemeinen Sicherheitsbestimmungen. Die Ausführung E5524E0402 ist ein Universalgerät und verhält sich je nach eingestellter Grundbetriebsart wie • ein elektronischer Summier- und Frequenzzähler (ab Seite 38) • ein elektronischer Anzeigezähler mit 2 Summierbereichen (ab Seite 40) • ein elektronischer Summier- und Zeitzähler (ab Seite 42) • ein elektronischer Zeitzähler mit 2 Zeitzählern (ab Seite 45) 1.2 Allgemeine Sicherheits- und Warnhinweise 1. Vor Durchführung von Installations- oder Wartungsarbeiten stellen Sie bitte sicher, dass die Digitalanzeige von der Versorgungsspannung getrennt ist. 2. Setzen Sie die Digitalanzeige nur bestimmungsgemäß ein: In technisch einwandfreiem Zustand. Unter Beachtung der Bedienungsanleitung und den allgemeinen Sicherheitsbestimmungen. 3. Beachten Sie länder- und anwendungsspezifische Bestimmungen 4. Die Digitalanzeige ist nicht geeingnet für den explosionsgeschützten Bereich und den Einsatzbereichen, die in EN 61010 Teil 1 ausgeschlossen sind. 5. Die Digitalanzeige darf nur im ordnungsgemäß eingebautem Zustand entsprechend dem Kapitel “Technische Daten” betrieben werden. 1.3 Bestimmungsgemäßer Gebrauch Die Digitalanzeige darf nur als Einbaugerät eingesetzt werden. Der Einsatzbereich dieser Anzeige liegt in industriellen Prozessen und Steuerungen. In den Bereichen von Fertigungsstraßen der Metall-, Holz-, Kunststoff-, Papier-, Glas- und Textilindustrie u.ä. Überspannungen an den Schraubklemmen der Digitalanzeige müssen auf den Wert der Überspannungskategorie II begrenzt sein. Wird die Digitalanzeige zur Überwachung von Maschinen oder Ablaufprozessen eingesetzt, bei denen infolge eines Ausfalls oder einer Fehlbedienung der Digitalanzeige eine Beschädigung der Maschine oder ein Unfall des Bedienungsper-sonals möglich ist, dann müssen Sie entsprechende Sicherheitsvorkehrungen treffen. MN05401010E 2. Einstellung der Betriebsparameter a. Beide Tasten auf der Vorderseite gedrückt halten und Spannungsversorgung einschalten, oder bei eingeschalteter Spannungsversorgung beide Tasten gleichzeitig 5 s drücken. b. Auf dem Display erscheint deutsch ! c. Sobald die Tasten losgelassen werden, erscheint auf dem Display c1. durch gedrückt halten der linken Taste und betätigen der rechten Taste wird der Programmiervorgang abgebrochen. c2. durch Drücken der rechten Taste wird auf umgeschaltet. d. Umschalten in den ersten Parameter durch gedrückt halten der linken Taste und betätigen der rechten Taste. 37 7/31/12 e. Sobald die Tasten losgelassen werden, erscheint in sekündlichen Wechsel der Menütitel und die aktuelle Menüpunkteinstellung. Nach Betätigen einer Taste wird nur noch die Menüpunkteinstellung angezeigt. f. Durch Drücken der rechten Taste wird die Menüpunkteinstellung jeweils um einen Wert weitergeschaltet. Wenn Zahlenwerte eingegeben werden sollen (z.B. bei der Faktoreinstellung), wird mit der linken Taste zunächst die Dekade angewählt und dann mit der rechten der Wert eingestellt. g. Umschalten auf den nächsten Menüpunkt durch gedrückt halten der linken Taste und betätigen der rechten Taste. h. Der jeweils letzte Menütitel „EndPro“ ermöglicht durch Anwahl von „YES“ das Verlassen des Programmiermenüs und die Übernahme (Speicherung) der neuen Werte. Wird „no“ angewählt, beginnt die Programmierroutine von vorne, wobei die zuletzt eingestellten Werte zunächst erhalten bleiben. Diese können nun nochmals verändert oder kontrolliert werden. 9:10 AM Page 38 Elektronischer Summier- und Frequenzzähler E5524E0402: Grundbetriebsart 1. Beschreibung • • • • • • 6-stelliger Summier- und Frequenzzähler LED-Anzeige, 8 mm hoch, rot Anzeigebereich von 0 ... 999 999 Vornullenunterdrückung Programmierung über zwei frontseitige Tasten Bedienerführung auf dem Display während der Programmierung • Umrechnung und Anzeige des Wertes in 1/s oder 1/min 2. Eingänge INP A Dynamischer Zähleingang/Frequenzeingang. RESET Dynamischer RESET-Eingang. Dieser ist mit der roten RESET-Taste parallel geschaltet und setzt den Zähler auf Null. 3. Programmierroutine Der erste Menüpunkt ist die Auswahl der Grundbetriebsart. Diese legt die Funktionen des Gerätes fest. Betriebsart Summierund Frequenzzähler, weiter unter 4. ab Seite 38 Betriebsart Anzeigezähler mit 2 Summierbereichen, weiter unter 4. ab Seite 40 Betriebsart Summierund Zeitzähler, weiter unter 4. ab Seite 43 Betriebsart Zeitzähler mit 2 Zeitbereichen, weiter unter 4. ab Seite 45 38 3. Auswahl des angezeigten Wertes Durch drücken der rechten Taste kann zwischen der Anzeige des Summierzählers und des Fequenzzählers umgeschaltet werden. Durch einmaliges Betätigen wird für 2 s die aktuelle Funktion („totAL“ oder „tAcho“) angezeigt. Wird innerhalb dieser Zeit die rechte Taste ein zweites Mal betätigt, so wird zur nächsten Funktion gewechselt und zur Bestätigung („totAL“ oder „tAcho“) für 2 s angezeigt. Danach wird der Wert der ausgewählten Funktion angezeigt. 4. Programmierroutine Nachfolgend sind die einstellbaren Parameter des Gerätes aufgeführt, die in der unten angegebenen Reihenfolge eingestellt werden können. Nach einem Durchlauf der Routine ist das Gerät vollständig programmiert. Die zuerst angegebenen Werte entsprechen der Werkseinstellung. MN05401010E - Technische Änderungen vorbehalten - MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarität der Eingänge npn: nach 0 V schaltend pnp: nach +UB schaltend 4.2 Zuschaltung des 30 Hz Filters (INP A) Der Filter bedämpft den Eingang* 9:10 AM Page 39 4.6 RESET-Mode (Summierer) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) 30 Hz-Filter aus (fmax) nur elektrische Rücksetzung über RESET-Eingang 30 Hz-Filter ein nur manuelle Rücksetzung über rote RESET-Taste 4.3 Multiplikationsfaktor (Summierer) 4.7 Multitplikationsfaktor (Frequenzzähler) Eine Einstellung von „0“ wird nicht akzeptiert. 4.4 Divisionsfaktor (Summierer) Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert ! deutsch Faktor von 00.0001 bis 99.9999 einstellbar. 4.8 Divisionsfaktor (Frequenzzähler) Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert. Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert! 4.5 Dezimalpunkteinstellung (Summierer) Der Dezimalpunkt legt Darstellung des Zählerstandes fest. Er hat keinen Einfluß auf die Zählung. 0 keine Dezimalstelle 0.0 eine Dezimalstelle 0.00 zwei Dezimalstellen 0.000 drei Dezimalstellen * bei Prellimpulsen, z.B. bei Kontakten MN05401010E 4.9 Dezimalpunkteinstellung (Frequenzzähler) Der Dezimalpunkt definiert die Auflösung im gewählten Messbereich 1/min oder 1/sec. 0 keine Dezimalstelle 0.0 eine Dezimalstelle 0.00 zwei Dezimalstellen 0.000 drei Dezimalstellen 39 MN05401010E.qxd:MN05401010E 7/31/12 4.10 Displaymode (Frequenzzähler) 4.11 Maximale Wartezeit (Frequenzzähler) Dieser Wert gibt an, wie lange bei gestarteter Messung gewartet werden soll, bis 0 angezeigt wird. Maximale Wartezeit 00.1 s (minimaler Wert) Maximale Wartezeit 99,9 s (maximaler Wert) 4.12 Ende der Programmierung Programmierroutine wird noch einmal durchlaufen. Bisher eingestellte Werte können überprüft und geändert werden. Programmierroutine wird beendet und alle eingestellten Werte werden als neue Parameter übernommen. Das Gerät ist anschließend betriebsbereit. Page 40 Elektronischer Anzeigezähler mit 2 Summierbereichen E5524E0402: Grundbetriebsart Umrechnung und Anzeige des Wertes in 1/s Umrechnung und Anzeige des Wertes in 1/min 9:10 AM 1. Beschreibung • • • • • • 6-stelliger Anzeigezähler mit Reset-Funktion LED-Anzeige, 8 mm hoch, rot Anzeigebereich von 0 ... 999 999 Vornullenunterdrückung Programmierung über zwei frontseitige Tasten Bedienerführung auf dem Display während der Programmierung 2. Eingänge INP A Dynamischer Zähleingang Zähler 1 und Zähler 2. RESET Dynamischer RESET-Eingang. Dieser ist mit der roten RESET-Taste parallel geschaltet und setzt den Zähler auf Null. Für Zähler 1 und Zähler 2 getrennt einstellbar 3. Auswahl des angezeigten Wertes Durch drücken der rechten Taste kann zwischen der Anzeige des Summierzählers 1 und des Summierzählers 2 umgeschaltet werden. Durch einmaliges Betätigen wird für 2 s die aktuelle Funktion („totAL1“ oder „totAL2“) angezeigt. Wird innerhalb dieser Zeit die rechte Taste ein zweites Mal betätigt, so wird zur nächsten Funktion gewechselt und zur Bestätigung („totAL1“ oder „totAL2“) für 2 s angezeigt. Danach wird der Wert der ausgewählten Funktion angezeigt. 4. Programmierroutine Nachfolgend sind die einstellbaren Parameter des Gerätes aufgeführt, die in der unten angegebenen Reihenfolge eingestellt werden können. Nach einem Durchlauf der Routine ist das Gerät vollständig programmiert. Die zuerst angegebenen Werte entsprechen der Werkseinstellung. 40 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarität der Eingänge npn: nach 0 V schaltend pnp: nach +UB schaltend 4.2 Zuschaltung des 30 Hz Filters (INP A) Der Filter bedämpft den Eingang* 30 Hz-Filter aus (fmax) 30 Hz-Filter ein 9:10 AM Page 41 4.6 RESET-Mode (Summierer 1) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) nur elektrische Rückstellung über RESET-Eingang nur manuelle Rückstellung über rote RESET-Taste 4.3 Multiplikationsfaktor Eine Einstellung von „0“ wird nicht akzeptiert. 4.4 Divisionsfaktor Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert. 4.5 Dezimalpunkteinstellung 4.7 RESET-Mode (Summierer 2) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) nur elektrische Rückstellung über RESET-Eingang nur manuelle Rückstellung über rote RESET-Taste Der Dezimalpunkt legt Darstellung des Zählerstandes fest. Er hat keinen Einfluß auf die Zählung. 0 keine Dezimalstelle 0.0 eine Dezimalstelle 0.00 zwei Dezimalstellen 0.000 drei Dezimalstellen * bei Prellimpulsen, z.B. bei Kontakten MN05401010E 41 deutsch Faktor von 00.0001 bis 99.9999 einstellbar. MN05401010E.qxd:MN05401010E 7/31/12 4.8 Ende der Programmierung 9:10 AM Page 42 Elektronischer Summier- und Zeitzähler E5524E0402: Grundbetriebsart Programmierroutine wird noch einmal durchlaufen. Bisher eingestellte Werte können überprüft und geändert werden. Programmierroutine wird beendet und alle eingestellten Werte werden als neue Parameter übernommen. Das Gerät ist anschließend betriebsbereit. 1. Beschreibung • 6-stelliger Summierer und Zeitzähler mit Reset-Funktion • LED-Anzeige, 8 mm hoch, rot • Anzeigebereich von 0 ... 999 999 • Vornullenunterdrückung • Programmierung über zwei frontseitige Tasten • Bedienerführung auf dem Display während der Programmierung • Laufanzeige: bei aktiver Zeitmessung blinkt der Dezimalpunkt der niederwertigsten Dekade • Zeitmessbetriebsarten: – Zeitmessung wenn INP B nicht aktiv „GAtE.Lo“ – Zeitmessung wenn INP B aktiv „GAtE.hi“ – Start/Stop der Zeitmessung mit Flanke INP B „Inb.Inb“ • Zeitmessbereiche: h; min; s; h.min.s 2. Eingänge INP A Dynamischer Zähleingang für Summierer. INP B Start-/Stop- oder Toreingang für Zeitzähler (abhängig von der Eingangsart) RESET Dynamischer RESET-Eingang. Dieser ist mit der roten RESET-Taste parallel geschaltet und setzt den Zähler auf Null. Für Summierer und Zeitzähler getrennt einstellbar. 3. Auswahl des angezeigten Wertes Durch drücken der rechten Taste kann zwischen der Anzeige des Summierzählers und des Zeitzählers umgeschaltet werden. Durch einmaliges Betätigen wird für 2 s die aktuelle Funktion („totAL“ oder „tiME“) angezeigt. Wird innerhalb dieser Zeit die rechte Taste ein zweites Mal betätigt, so wird zur nächsten Funktion gewechselt und zur Bestätigung („totAL“ oder „tiME“) für 2 s angezeigt. Danach wird der Wert der ausgewählten Funktion angezeigt. 42 MN05401010E 7/31/12 4. Programmierroutine 9:10 AM Page 43 4.5 Dezimalpunkteinstellung (Summierer) Nachfolgend sind die einstellbaren Parameter des Gerätes aufgeführt, die in der unten angegebenen Reihenfolge eingestellt werden können. Nach einem Durchlauf der Routine ist das Gerät vollständig programmiert. Der Dezimalpunkt legt Darstellung des Zählerstandes fest. Er hat keinen Einfluß auf die Zählung. Die zuerst angegebenen Werte entsprechen der Werkseinstellung. 0 keine Dezimalstelle 0.0 eine Dezimalstelle 0.00 zwei Dezimalstellen 0.000 drei Dezimalstellen 4.1 Polarität der Eingänge npn: nach 0 V schaltend pnp: nach +UB schaltend 4.2 Zuschaltung des 30 Hz Filters (INP A, INP B) Der Filter bedämpft den Eingang* 30 Hz-Filter aus (fmax) Zähleingang und Start-/ Stopeingang unbedämpft 30 Hz-Filter ein Zähleingang und Start-/ Stopeingang bedämpft 4.3 Multiplikationsfaktor (Summierer) Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert. 4.4 Divisionsfaktor (Summierer) Faktor von 00.0001 bis 99.9999 einstellbar. Eine Einstellung von „0“ wird nicht akzeptiert. 4.6 RESET-Mode (Summierer) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) nur elektrische Rückstellung über RESET-Eingang nur manuelle Rückstellung über rote RESET-Taste 4.7 Eingangsart (Zeitzähler) Start/Stop über Inp B. Zeitmessung wenn Inp B (Tor) nicht aktiv oder offen Start/Stop über Inp B. Zeitmessung wenn Inp B (Tor) aktiv (High-Pegel bei pnp; Low-Pegel bei npn) Zeitmessung wird mit INP B gestartet und gestoppt (LOW-HIGH Flanke bei pnp; HIGHLOW Flanke bei npn). Jede aktive Flanke ändert Zählstatus. * bei Prellimpulsen, z.B. bei Kontakten MN05401010E 43 deutsch MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 44 4.10 RESET-Mode (Zeitzähler) 4.8 Betriebsart (Zeitzähler) Zeiteinheit Sekunden (Dezimalpunkteinstellung bestimmt Auflösung*) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang Zeiteinheit: Minuten (Dezimalpunkteinstellung bestimmt Auflösung*) keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) Zeiteinheit: Stunden (Dezimalpunkteinstellung bestimmt Auflösung*) nur elektrische Rückstellung über RESET-Eingang Zeiteinheit: Stunden:Minuten:Sekunden (Dezimalpunkteinstellung wird übersprungen) nur manuelle Rückstellung über rote RESET-Taste 4.11 Ende der Programmierung *0, 0.1, 0.01, 0.001 bedeutet: Zeitmessung in 0, 0,1, 0,01, 0,001 Zeiteinheiten (siehe 4.9) 4.9 Dezimalpunkteinstellung (Zeitzähler) Der Dezimalpunkt legt die Auflösung der programmierten Zeiteinheit fest. 0 0.0 0.00 0.000 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) Programmierroutine wird noch einmal durchlaufen. Bisher eingestellte Werte können überprüft und geändert werden. Programmierroutine wird beendet und alle eingestellten Werte werden als neue Parameter übernommen. Das Gerät ist anschließend betriebsbereit. 44 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Elektronischer Zeitzähler mit 2 Zeitbereichen E5524E0402: Grundbetriebsart 9:10 AM Page 45 4. Programmierroutine Nachfolgend sind die einstellbaren Parameter des Gerätes aufgeführt, die in der unten angegebenen Reihenfolge eingestellt werden können. Nach einem Durchlauf der Routine ist das Gerät vollständig programmiert. 1. Beschreibung 6-stelliger Zeitzähler mit Reset-Funktion LED-Anzeige, 8 mm hoch, rot Anzeigebereich von 0 ... 999 999 Vornullenunterdrückung Programmierung über zwei frontseitige Tasten Bedienerführung auf dem Display während der Programmierung • Laufanzeige: bei aktiver Zeitmessung blinkt der Dezimalpunkt der niederwertigsten Dekade • Zeitmessbetriebsarten: – Zeitmessung wenn INP B nicht aktiv „GAtE.Lo“ – Zeitmessung wenn INP B aktiv „GAtE.hi“ – Start/Stop der Zeitmessung mit Flanke INP B (Inb.Inb) – Start der Zeitmessung mit Flanke Inp A, Stop der Zeitmessung mit Flanke INP B (InA.InB) • Zeitmessbereiche: h; min; s; h.min.s Die zuerst angegebenen Werte entsprechen der Werkseinstellung. 4.1 Polarität der Eingänge npn: nach 0 V schaltend pnp: nach +UB schaltend deutsch • • • • • • 2. Eingänge INP A Starteingang (abhängig von der Eingangsart) INP B Start-/Stop- oder Toreingang für Zeitzähler (abhängig von der Eingangsart) RESET Dynamischer RESET-Eingang. Dieser ist mit der roten RESET-Taste parallel geschaltet und setzt den Zähler auf Null. Für Zähler 1 und Zähler 2 getrennt einstellbar. 3. Auswahl des angezeigten Wertes Durch drücken der rechten Taste kann zwischen der Anzeige des Zeitzählers 1 und des Zeitzählers 2 umgeschaltet werden. Durch einmaliges Betätigen wird für 2 s die aktuelle Funktion („tiME1“ oder „tiME2“) angezeigt. Wird innerhalb dieser Zeit die rechte Taste ein zweites Mal betätigt, so wird zur nächsten Funktion gewechselt und zur Bestätigung („tiME1“ oder „tiME2“) für 2 s angezeigt. Danach wird der Wert der ausgewählten Funktion angezeigt. MN05401010E 4.2 Zuschaltung des 30 Hz Filters (INP A, INP Der Filter bedämpft den Eingang* 30 Hz-Filter aus (fmax) Start-/Stopeingang unbedämpft 30 Hz-Filter ein Bedämpfung der Start und Stopeingänge * bei Prellimpulsen, z.B. bei Kontakten 45 MN05401010E.qxd:MN05401010E 7/31/12 4.3 Eingangsart (Zeitzähler) Start/Stop über Inp B. Zeitmessung wenn Inp B (Tor) nicht aktiv oder offen Start/Stop über Inp B. Zeitmessung wenn Inp B (Tor) aktiv (High-Pegel bei pnp; Low-Pegel bei npn) Zeitmessung wird mit INP B gestartet und gestoppt (LOW-HIGH Flanke bei pnp; HIGHLOW Flanke bei npn). Jede aktive Flanke ändert Zählstatus. Zeitmessung wird mit INP A gestartet, mit INP B gestoppt. (LOW-HIGH Flanke bei pnp; HIGHLOW Flanke bei npn) 9:10 AM Page 46 4.5 Dezimalpunkteinstellung Der Dezimalpunkt legt die Auflösung der programmierten Zeiteinheit fest. 0 0.0 0.00 0.000 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 4.6 RESET-Mode (Zeitbereich 1) manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) nur elektrische Rückstellung über RESET-Eingang nur manuelle Rückstellung über rote RESET-Taste 4.4 Betriebsart 4.7 RESET-Mode (Zeitbereich 2) Zeiteinheit Sekunden (Dezimalpunkteinstellung bestimmt Auflösung*) Zeiteinheit: Minuten (Dezimalpunkteinstellung bestimmt Auflösung*) Zeiteinheit: Stunden (Dezimalpunkteinstellung bestimmt Auflösung*) Zeiteinheit: Stunden:Minuten:Sekunden (Dezimalpunkteinstellung wird übersprungen) *0, 0.1, 0.01, 0.001 bedeutet: Zeitmessung in 0, 0,1, 0,01, 0,001 Zeiteinheiten 46 manuelle Rückstellung über die rote RESET-Taste und elektrische Rückstellung über RESET-Eingang keine Rückstellung möglich (rote RESET-Taste und RESET-Eingang gesperrt) nur elektrische Rückstellung über RESET-Eingang nur manuelle Rückstellung über rote RESET-Taste MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Frequenzmessung: Genauigkeit: < 0,1 % Programmierroutine wird noch einmal durchlaufen. Bisher eingestellte Werte können überprüft und geändert werden. Programmierroutine wird beendet und alle eingestellten Werte werden als neue Parameter übernommen. Das Gerät ist anschließend betriebsbereit. 5. Technische Daten Spannungsversorgung Versorgung: Page 47 10 ... 30 V DC/max. 40 mA mit Verpolschutz Messprinzip: < 38Hz: > 38 Hz: Zeitmessbereiche: Sekunden Minuten Stunden h.min.s Genauigkeit Periodendauermessung Torzeitmessung Torzeit 26,3 ms 0,001 s ... 999 999 s 0,001min ... 999 999 min 0,001 h ... 999 999 h 00 h 00 min 01 s ... 99 h 59 min 59 s <50 ppm Mindestimpulsdauer des Rücksetzeingangs: 5 ms Schaltpegel der Eingänge: Standard-Pegel: Low: 0 ... 0,2 x UB [V DC] High: 0,6 x UB ... 30 [V DC] UB = Netzspannung Anzeige: 6-stellige rote 7-Segment LED-Anzeige, 8 mm hoch 5 V-Pegel: Low: 0 ... 2 V DC High: 4 ...30 V DC Datensicherung: EEPROM Impulsform: beliebig*, Schmitt-Trigger-Eingang Polarität der Eingänge: Programmierbar, npn oder pnp für alle Eingänge Eingangswiderstand: ca. 5 kΩ Zählfrequenzen: DC-Versorgung Eingangspegel: typ. Low Pegel: typ. High Pegel: Fmax*: tot.tac tot.tot tot.ti1) tot.ti2) 24 V 12 V Standard 2,5 V 2,0 V 22,0 V 10 V kHz kHz 35 20 60 20 40 20 15 10 Umgebungstemperatur: –20 ... +65 °C bei 10 ... 26 V DC –20 ... +55 °C bei >26 ... 30 V DC Lagertemperatur: –25 ... +70 °C 10 ... 30 V 5V 1,0 V 4,0 V kHz 8 8 8 8 1) Start Gate.Lo Inp B nicht aktiv 2) Start InpB.InpB und Inp B mit Inp A verbunden *bei maximaler Frequenz Rechteckimpulse 1:1 MN05401010E deutsch 4.8 Ende der Programmierung 9:10 AM EMV: CE-Konform zur EG-Richtlinie 2004/108/EWG Störabstrahlung EN 61 000-6-3 EN 55 011 Klasse B Störfestigkeit EN 61 000-6-2 Gehäuse: Schalttafelgehäuse: 48 x 24 mm nach DIN 43700, RAL7021, dunkelgrau Gewicht: ca. 50 g Schutzart: IP 65 (frontseitig) Reinigung: Die Frontseiten der Geräte dürfen nur mit einem weichen, mit Wasser angefeuchteten Tuch gereinigt werden. 47 MN05401010E.qxd:MN05401010E 7/31/12 6. Anschlussbelegung 1 2 3 4 5 9:10 AM Page 48 7. Lieferumfang: 1 Digitalanzeige 1 Spannbügel 1 Frontrahmen für Spannbügelbefestigung, für Einbauquerschnitt 50 x 25 mm 1 Frontrahmen für Schraubbefestigung, für Einbauquerschnitt 50 x 25 mm 1 Dichtung 1 Bedienungsanleitung multilingual 10 ... 30 V DC 0 V GND INP A INP B Reset 8. Abmessungen: max. 19.3 [0.76] 24 [0.94] 22 x 5 [0.87 x 1.77] 48 [1.89] Schalttafelausschnitt: 22,2+0,3 x 45+0,6 mm 4 [0.16] 6.5 [0.26] 59 [2.32] Einbaurahmen Schalttafelausschnitt: 53 [2.09] 25 + 0.5 [0.98 + 0.02] 26 [1.10] 25 x 50 [0.98 x 1.97] 50 + 0.6 [1.97 + 0.02] 1 [0.04] 4 [0.16] 56 [2.20] 1 48 1 [0.04] 4 [0.16] 32 ± 0.01 [1.26 ± 0.004] 25 [0.98] 25 x 50 [0.98 x 1.97] 32 [ 1.26] 40 [1.57] 50 [1.97] M3 1 Senkung Af3, DIN 74 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 49 Istruzioni per l’uso Contatori con display elettronici E5524E0402 1.1 Istruzioni per la sicurezza e avvertenze Utilizzare questi visualizzatori solo – in maniera conforme alla loro destinazione – se la loro condizione tecnica è perfetta – osservando le istruzioni di utilizzo e le norme generali di sicurezza. ! 1.2 norme generali di sicurezza. 1. Prima di qualsiasi lavoro d'installazione o di manutenzione, accertarsi che l’alimentazione del visualizzatore digitale sia interrotta. 2. Utilizzare questo visualizzatore solo in maniera conforme alla sua destinazione: La sua condizione tecnica deve essere perfetta. Osservare le istruzioni di utilizzo e le norme generali di sicurezza. 3. Rispettare le norme specifiche al paese e all’utilizzatore. 4. Il visualizzatore digitale non conviene per delle zone che presentino rischi d'esplosione, né per i campi d'utilizzo esclusi della norma EN 61010, Parte 1. 5. Il visualizzatore digitale deve funzionare solo se è stato inserito a regola d’arte, in conformità con le prescrizioni del capitolo “Caratteristiche tecniche generali”. 1.4 Descrizione Il modello E5524E0402 è stato concepito in modo tale da farne un apparecchio universale. Secondo il modo di funzionamento selezionato, esso si comporta come • un totalizzatore e frequenzimetro elettronico (vedi pagina 50) • un contatore con display elettronico, con 2 campi di totalizzazione (vedi pagina 52) • un totalizzatore e contatore di tempo elettronico (vedi pagina 54) • un contatore di tempo elettronico con 2 contatori di tempo (vedi pagina 57) 2. Regolazione dei parametri di funzionamento a. Premere i due tasti sulla parte anteriore e mettere l’apparecchio sotto tensione o, qualora l’apparecchio sia sotto tensione, premere i due tasti per 5 secondi. b. Sul display compare il seguente messaggio c. Al rilascio dei tasti, il display visualizza Il visualizzatore digitale può essere utilizzato solo in qualità d'apparecchiatura incassata. Questo prodotto trova la sua applicazione nei processi industriali ed i comandi, nel campo delle linee di produzione delle industrie metallurgiche, del legno, delle materie plastiche, della carta, del vetro, dei tessili eccetera. Le sovratensioni ai terminali dell’apparecchiatura devono essere limitate ai valori della categoria di sovratensione II. Se il visualizzatore digitale è utilizzato per la sorveglianza di macchine o di processi ove, in caso di guasto o di errori di manipolazione dell’apparecchio, possano presentarsi rischi di danni alla macchina o d’incidenti per gli operatori, l’utente deve assumere la responsabilità per le opportune misure di sicurezza. MN05401010E italiano 1.3 Utilizzazione in conformità c1.Mantenere il tasto sinistro premuto, poi premere il tasto destro per interrompere l’operazione di programmazione. c2. Premere il tasto destro. Il display indica . d. Mantenere il tasto sinistro premuto, poi premere il tasto destro per richiamare il primo parametro. 49 7/31/12 9:10 AM Page 50 e. Al rilascio dei tasti, compare, ad intervalli di un secondo, il titolo del menu e la regolazione del punto del menu in essere. Premere un tasto: la visualizzazione alternata cessa ed il display indica solo la regolazione del punto del menu. Totalizzatore e frequenzimetro elettronico f. Un impulso sul tasto destro consente di passare al valore successivo del parametro in fase di regolazione. Per inserire dei dati numerici (per esempio al momento della regolazione del fattore), selezionare prima la decade tramite il tasto sinistro, poi regolare il suo valore con il tasto destro. 1. Descrizione g. Mantenere il tasto sinistro premuto, poi premere il tasto destro per richiamare il punto successivo del menu. E5524E0402: Modo di funzionamento • • • • • Totalizzatore e frequenzimetro a 6 decadi Display a LED rossi, altezza 8 mm Campo di visualizzazione 0 ... 999 999 Soppressione degli zeri in testa Programmazione tramite due tasti sulla parte frontale • Programmazione guidata tramite messaggi sul display • Conversione e visualizzazione del valore in 1/s o 1/min h. L’ultimo parametro del menu “EndPro” permette, selezionando “Yes”, di uscire dal menu di programmazione e di salvare i nuovi valori. Selezionando “no”, la programmazione riparte dall’inizio, conservando gli ultimi valori inseriti. In questo modo, è possibile controllarli e modificarli di nuovo. 2. Entrate 3. Routine di programmazione 3. Selezione del valore visualizzato Il primo punto del menu è la selezione del modo di funzionamento base. Determina le funzioni dell’apparecchio. Premere il tasto destro per commutare dal display del totalizzatore a quello del frequenzimetro. Un impulso unico visualizza per 2 secondi la funzione corrente (“total” o “tacho”). Qualora il tasto di destra sia premuto nuovamente durante questo lasso di tempo, il sistema passa alla funzione corrente ed il display visualizza (“total” o “tacho”) per 2 secondi per confermare. In seguito, il valore della funzione selezionata è visualizzato. Modo contatore totalizzatore e frequenzimetro, vedi par. 4, pagina 50 Modo contatore con display, con 2 campi di totalizzazione, vedi par. 4, pagina 52 Modo contatore totalizzatore e contatore di tempo, vedi par. 4, pagina 55 Modo contatore di tempo con 2 contatori di tempo, vedi par. 4, pagina 57 50 INP A Entrata di conteggio/di frequenza dinamica. RESET Entrata RESET dinamica accoppiata in parallelo con il tasto RESET rosso. Azzera il contatore. 4. Routine di programmazione I parametri regolabili dell’apparecchio sono indicati di seguito nell’ordine in cui sono visualizzati sul display. Perciò, la programmazione dell’apparecchio è completata dopo un ciclo di programmazione. I primi valori indicati corrispondono a quelli regolati in fabbrica. MN05401010E - Sotto riserva di modifiche tecniche - MN05401010E.qxd:MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarità delle entrate npn: commutazione a 0 V pnp: commutazione a +UB 4.2 Attivazione del filtro 30Hz (INP A) Il filtro permette di impostare la frequenza max di conteggio all’ingresso* Filtro 30 Hz disattivato (fmax) Filtro 30 Hz attivato 4.3 Fattore di moltiplicazione (totalizzatore) Fattore regolabile da 00.0001 a 99.9999. La regolazione a “0” non è accettata. 9:10 AM Page 51 4.6 Modo RESET (totalizzatore) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET Solo ripristino manuale tramite il tasto RESET rosso 4.7 Fattore di moltiplicazione (frequenzimetro) Fattore regolabile da 00.0001 a 99.9999. La regolazione a “0” non è accettata. 4.4 Fattore di divisione (totalizzatore) 4.8 Fattore di divisione (frequenzimetro) Fattore regolabile da 00.0001 a 99.9999. 4.5 Regolazione del punto decimale (totalizzatore) Il punto decimale determina la rappresentazione del valore di conteggio. Non ha nessun effetto sul conteggio. 0 nessuna decimale 0.0 una decimale 0.00 due decimali 0.000 tre decimali * dove si verifica una pendolazione, per esempio con i contatti MN05401010E Fattore regolabile da 00.0001 a 99.9999. italiano La regolazione a “0” non è accettata. La regolazione a “0” non è accettata. 4.9 Regolazione del punto decimale (frequenzimetro) Il punto decimale determina la risoluzione. 0 nessuna decimale 0.0 una decimale 0.00 due decimali 0.000 tre decimali 51 MN05401010E.qxd:MN05401010E 7/31/12 4.10 Modo di visualizzazione (frequenzimetro) Conversione e visualizzazione del valore in 1/s Conversione e visualizzazione del valore in 1/min 4.11 Attesa massima (frequenzimetro) Questo valore indica quanto tempo il sistema deve aspettare un impulso, la misura essendo attiva, prima di visualizzare 0. Attesa massima 00.1 s (valore minimo) Attesa massima 99,9 s (valore massimo) 4.12 Fine della programmazione La programmazione è realizzata ancora una volta. I valori inseriti possono essere controllati e modificati. La programmazione è conclusa ed i valori inseriti sono presi in considerazione come nuovi parametri. Ora, l’apparecchio è pronto per il funzionamento. 9:10 AM Page 52 Contatore con display elettronico, con 2 campi di totalizzazione E5524E0402: Modo di funzionamento 1. Descrizione • Contatore con display a 6 decadi, con funzione Reset • Display a LED rossi, altezza 8 mm • Campo di visualizzazione 0 ... 999 999 • Soppressione degli zeri in testa • Programmazione tramite due tasti sulla parte frontale • Programmazione guidata tramite messaggi sul display. 2. Entrate INP A Entrata di conteggio dinamica Contatore 1 e Contatore 2. RESET Entrata RESET dinamica accoppiata in parallelo con il tasto RESET rosso. Azzera il contatore. Regolabile separatamente per il contatore 1 e il contatore 2. 3. Selezione del valore visualizzato Premere il tasto destro per commutare dal display del totalizzatore 1 a quello del totalizzatore 2. Un impulso unico visualizza per 2 secondi la funzione corrente (“total1” o “total2”). Qualora il tasto di destra sia premuto nuovamente durante questo lasso di tempo, il sistema passa alla funzione corrente ed il display visualizza (“total1” o “total2”) per 2 secondi per confermare. In seguito, il valore della funzione selezionata è visualizzato. 4. Routine di programmazione I parametri regolabili dell’apparecchio sono indicati di seguito nell’ordine in cui sono visualizzati sul display. Perciò, la programmazione dell’apparecchio è completata dopo un ciclo di programmazione. I primi valori indicati corrispondono a quelli regolati in fabbrica. 52 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.1 Polarità delle entrate npn: commutazione a 0 V pnp: commutazione a +UB 4.2 Attivazione del filtro 30Hz (INP A) Il filtro permette di impostare la frequenza max di conteggio all’ingresso* Filtro 30 Hz disattivato (fmax) Filtro 30 Hz attivato 9:10 AM Page 53 4.6 Modo RESET (totalizzatore 1) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET Solo ripristino manuale tramite il tasto RESET rosso 4.3 Fattore di moltiplicazione La regolazione a “0” non è accettata. 4.4 Fattore di divisione Fattore regolabile da 00.0001 a 99.9999. La regolazione a “0” non è accettata. 4.5 Regolazione del punto decimale Il punto decimale determina la rappresentazione del valore di conteggio. Non ha nessun effetto sul conteggio. 4.7 Modo RESET (totalizzatore 2) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET italiano Fattore regolabile da 00.0001 a 99.9999. Solo ripristino manuale tramite il tasto RESET rosso 0 nessuna decimale 0.0 una decimale 0.00 due decimali 0.000 tre decimali * dove si verifica una pendolazione, per esempio con i contatti MN05401010E 53 MN05401010E.qxd:MN05401010E 7/31/12 4.8 Fine della programmazione 9:10 AM Page 54 Totalizzatore e contatore di tempo elettronico E5524E0402: Modo di funzionamento La programmazione è realizzata ancora una volta. I valori inseriti possono essere controllati e modificati. La programmazione è conclusa ed i valori inseriti sono presi in considerazione come nuovi parametri. Ora, l’apparecchio è pronto per il funzionamento. 1. Descrizione • Totalizzatore e contatore di tempo a 6 decadi, con funzione Reset • Display a LED rossi, altezza 8 mm • Campo di visualizzazione 0 ... 999 999 • Soppressione degli zeri in testa • Programmazione tramite due tasti sulla parte frontale • Programmazione guidata tramite messaggi sul display • Indicazione di funzionamento: il punto decimale della decade più bassa lampeggia quando la misura di tempo è attiva • Modi di funzionamento per la misura di tempo: – Misura se INP B non è attivo “GAtE.Lo” – Misura se INP B è attivo “GAtE.hi” – Start/Stop della misura tramite fronte INP B “Inb.Inb” • Campi di misura di tempo: h; min; s; h.min.s 2. Entrate INP A Entrata di conteggio dinamica per il totalizzatore. INP B Entrata di Start-/Stop o entrata di porta per il contatore di tempo (secondo il tipo d’entrata selezionato) RESET Entrata RESET dinamica accoppiata in parallelo con il tasto RESET rosso. Azzera il contatore. Regolabile separatamente per il totalizzatore e per il contatore di tempo. 3. Selezione del valore visualizzato Premere il tasto destro per commutare dal display del totalizzatore a quello del contatore di tempo. Un impulso unico visualizza per 2 secondi la funzione corrente (“total” o “time”). Qualora il tasto di destra sia premuto nuovamente durante questo lasso di tempo, il sistema passa alla funzione corrente ed il display visualizza (“tota1” o “timer”) per 2 secondi per confermare. In seguito, il valore della funzione selezionata è visualizzato. 54 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4. Routine di programmazione 9:10 AM Page 55 4.5 Regolazione del punto decimale (totalizzatore) I parametri regolabili dell’apparecchio sono indicati di seguito nell’ordine in cui sono visualizzati sul display. Perciò, la programmazione dell’apparecchio è completata dopo un ciclo di programmazione. Il punto decimale determina la rappresentazione del valore di conteggio. Non ha nessun effetto sul conteggio. I primi valori indicati corrispondono a quelli regolati in fabbrica. 0 nessuna decimale 0.0 una decimale 0.00 due decimali 0.000 tre decimali 4.1 Polarità delle entrate npn: commutazione a 0 V pnp: commutazione a +UB 4.2 Attivazione del filtro 30Hz (INP A, INP B) Il filtro permette di impostare la frequenza max di conteggio all’ingresso* Filtro 30 Hz disattivato (fmax) Entrate di conteggio e di Start-Stop non amortizzate Filtro 30 Hz attivato Entrate di conteggio e di Start-Stop amortizzate 4.6 Modo RESET (totalizzatore) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET Solo ripristino manuale tramite il tasto RESET rosso 4.7 Tipo d’entrata (contatore di tempo) Fattore regolabile da 00.0001 a 99.9999. La regolazione a “0” non è accettata. 4.4 Fattore di divisione (totalizzatore) Fattore regolabile da 00.0001 a 99.9999. La regolazione a “0” non è accettata. * dove si verifica una pendolazione, per esempio con i contatti MN05401010E Start/Stop tramite Inp B. Misura di tempo se Inp B (porta) non è attivo o è aperto Start/Stop tramite Inp B. Misura di tempo se Inp B (porta) è attivo (livello alto per pnp; livello basso per npn) Start e Stop della misura di tempo tramite INP B (fronte d’impulso ascendente per pnp; fronte discendente per npn). Ogni fronte attiva modifica lo stato del conteggio. 55 italiano 4.3 Fattore di moltiplicazione (totalizzatore) MN05401010E.qxd:MN05401010E 7/31/12 4.8 Modo di funzionamento (contatore di tempo) 9:10 AM Page 56 4.10 Modo RESET (contatore di tempo) Unità di tempo: secondi (la regolazione del punto decimale determina la risoluzione*) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Unità di tempo: minuti (la regolazione del punto decimale determina la risoluzione*) Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Unità di tempo: ore (la regolazione del punto decimale determina la risoluzione*) Solo ripristino elettrico tramite l’entrata RESET Unità di conteggio: Ore:Minuti:Secondi (la regolazione del punto decimale è ignorata) Solo ripristino manuale tramite il tasto RESET rosso 4.11 Fine della programmazione *0, 0.1, 0.01, 0.001 significa: misura di tempo in 0, 0,1, 0,01, 0,001 unità di tempo 4.9 Regolazione del punto decimale (contatore di tempo) Il punto decimale determina la risoluzione dell’unità di tempo programmata. 0 1 0.0 1/10 (0,1) 0.00 1/100 (0,01) 0.000 1/1000 (0,001) 56 La programmazione è realizzata ancora una volta. I valori inseriti possono essere controllati e modificati. La programmazione è conclusa ed i valori inseriti sono presi in considerazione come nuovi parametri. Ora, l’apparecchio è pronto per il funzionamento. MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 Contatore di tempo elettronico con 2 contatori E5524E0402: Modo di funzionamento 9:10 AM Page 57 4. Routine di programmazione I parametri regolabili dell’apparecchio sono indicati di seguito nell’ordine in cui sono visualizzati sul display. Perciò, la programmazione dell’apparecchio è completata dopo un ciclo di programmazione. 1. Descrizione • Contatore di tempo a 6 decadi, con funzione Reset • Display a LED rossi, altezza 8 mm • Campo di visualizzazione 0 ... 999 999 • Soppressione degli zeri in testa • Programmazione tramite due tasti sulla parte frontale • Programmazione guidata tramite messaggi sul display • Indicazione di funzionamento: il punto decimale della decade più bassa lampeggia quando il conteggio è attivo. • Modi di funzionamento per la misura di tempo: – Misura se INP B non è attivo “GAtE.Lo” – Misura se INP B è attivo “GAtE.hi” – Start/Stop della misura tramite fronte INP B (Inb.Inb) – Start della misura tramite fronte Inp A, Stop della misura tramite fronte INP B (InA.InB) • Campi di misura di tempo: h; min; s; h.min.s I primi valori indicati corrispondono a quelli regolati in fabbrica. 4.1 Polarità delle entrate npn: commutazione a 0 V pnp: commutazione a +UB 2. Entrate 4.2 Attivazione del filtro 30Hz (INP A, INP B) Il filtro permette di impostare la frequenza max di conteggio all’ingresso* Filtro 30 Hz disattivato (fmax) Entrate di Start/Stop non amortizzate 3. Selezione del valore visualizzato Premere il tasto destro per commutare dal display del contatore di tempo 1 a quello del contatore di tempo 2. Un impulso unico visualizza per 2 secondi la funzione corrente (“time1” o “time2”). Qualora il tasto di destra sia premuto nuovamente durante questo lasso di tempo, il sistema passa alla funzione corrente ed il display visualizza (“time1” o “time2”) per 2 secondi per confermare. In seguito, il valore della funzione selezionata è visualizzato. MN05401010E Filtro 30 Hz attivato Amortizzamento delle entrate di Start/Stop per un comando per contatti meccanici * dove si verifica una pendolazione, per esempio con i contatti 57 italiano INP A Entrata di Start (secondo il tipo d’entrata selezionato) INP B Entrata di Start/Stop o entrata di porta per il contatore di tempo (secondo il tipo d’entrata selezionato) RESET Entrata RESET dinamica accoppiata in parallelo con il tasto RESET rosso. Azzera il contatore. Regolabile separatamente per il contatore 1 e il contatore 2. MN05401010E.qxd:MN05401010E 7/31/12 4.3 Tipo d’entrata (contatore di tempo) Start/Stop tramite Inp B. Misura di tempo se Inp B (porta) non è attivo o è aperto. Start/Stop tramite Inp B. Misura di tempo se Inp B (porta) è attivo (livello alto per pnp; livello basso per npn) Start e Stop della misura di tempo tramite INP B (fronte d’impulso ascendente per pnp; fronte discendente per npn). Ogni fronte attiva modifica lo stato del conteggio. Start della misura di tempo tramite INP A, Stop tramite INP B. (fronte d’impulso ascendente per pnp; fronte discendente per npn) 4.4 Modo di funzionamento 9:11 AM Page 58 4.5 Regolazione del punto decimale Il punto decimale determina la risoluzione dell’unità di tempo programmata. 0 0.0 0.00 0.000 1 1/10 (0,1) 1/100 (0,01) 1/1000 (0,001) 4.6 Modo RESET (contatore di tempo 1) Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET Solo ripristino manuale tramite il tasto RESET rosso 4.7 Modo RESET (contatore di tempo 2) Unità di tempo: secondi (la regolazione del punto decimale determina la risoluzione*) Unità di tempo: minuti (la regolazione del punto decimale determina la risoluzione*) Unità di tempo: ore (la regolazione del punto decimale determina la risoluzione*) Unità di conteggio: Ore:Minuti:Secondi (la regolazione del punto decimale è ignorata) *0, 0.1, 0.01, 0.001 significa: misura di tempo in 0, 0,1, 0,01, 0,001 unità di tempo 58 Ripristino manuale tramite il tasto RESET rosso ed elettrico tramite l’entrata RESET Nessun ripristino (tasto RESET rosso ed entrata RESET disattivati) Solo ripristino elettrico tramite l’entrata RESET Solo ripristino manuale tramite il tasto RESET rosso MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 4.8 Fine della programmazione Principio di misura: < 38 Hz: Misura di durata di periodo > 38 Hz: Misura del tempo di porta tempo di porta = 26,6 ms La programmazione è conclusa ed i valori inseriti sono presi in considerazione come nuovi parametri. Campi di misura del tempo: Secondi 0,001 s ... 999 999 s Minuti 0,001min ... 999 999 min Ore 0,001 h ... 999 999 h h.min.s 00 h 00 min 01 s ... 99 h 59 min 59 s Precisione <50 ppm Ora, l’apparecchio è pronto per il funzionamento. Durata minima dell’impulso sull’entrata di rimessa a zero: 5 ms 5. Caratteristiche tecniche Tensione d’alimentazione Alimentazione: 10 ... 30 V CC/max. 40 mA Con protezione contro le inversioni di polarità Display: 6 decadi, LED rossi a 7 segmenti, altezza 8 mm Memorizzazione dei dati: EEPROM Polarità delle entrate: Programmabile, npn o pnp per tutte le entrate Livello 5 V: Low: 0 ... 1 V CC High: 4 ...30 V CC Forma degli impulsi: qualsiasi*, entrata tramite trigger di Schmitt Temperatura ambiente: –20 ... +65 °C a 10 ... 26 V DC –20 ... +55 °C a >26 ... 30 V DC 10 ... 30 V 5V 1,0 V 4,0 V kHz 8 8 8 8 1) Start Gate.Lo Inp B non actif 2) Start InpB.InpB è Inp B con Inp A * alla massima frequenza l’onda quadra è 1:1 italiano Frequenze di conteggio: 24 V 12 V Standard 2,5 V 2,0 V 22,0 V 10 V kHz kHz 35 20 60 20 40 20 15 10 Livello di commutazione delle entrate: Livello standard: Low: 0 ... 0,2 x UB [V CC] High: 0,6 x UB ... 30 [V CC] UB = Tensione di alimentazione Temperatura di immagazzinamento: –25 ... +70 °C Resistenza d’entrata: circa. 5 kΩ MN05401010E Page 59 Misura di frequenza: Precisione: < 0,1 % La programmazione è realizzata ancora una volta. I valori inseriti possono essere controllati e modificati. Alimentazione CC: Livello: typ. low: typ. high: Fmax*: tot.tac tot.tot tot.ti1) tot.ti2) 9:11 AM CEM : Conforme alla direttiva CE 2004/108/CEE Emissione di parassiti EN EN 61 000-6-3/ EN 55 011 Classe B Immunità ai parasiti EN 61 000-6-2 Contenitore : Per montaggio in pannello:48 x 24 mm in accordo con DIN 43700, RAL7021, grigio scuro Peso: circa 50 g Grado di protezione: IP 65 (frontale) Pulizia : Le parti frontali degli apparecchi devono essere pulite esclusivamente con uno straccio morbido umido. 59 MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 60 6. Collegamenti 7. La consegna include 1 2 3 4 5 1 Display digitale 1 Staffa di fissaggio 1 frontale per montaggio con viti, pannelo 50 x 25 1 clip per lannello di montaggio, pannelo 50 x 50 1 Sigillare 1 Manuale operativo multilingua 10 ... 30 V DC 0 V GND INP A INP B Reset 8. Dimensioni: max. 19.3 [0.76] 24 [0.94] 22 x 5 [0.87 x 1.77] 48 [1.89] Sfinestratura pannello: 22,2+0,3 x 45+0,6 mm 4 [0.16] 6.5 [0.26] 59 [2.32] Cornice anteriore Sfinestratura pannello: 53 [2.09] 25 + 0.5 [0.98 + 0.02] 26 [1.10] 25 x 50 [0.98 x 1.97] 50 + 0.6 [1.97 + 0.02] 1 [0.04] 4 [0.16] 56 [2.20] 1 60 1 [0.04] 4 [0.16] 32 ± 0.01 [1.26 ± 0.004] 25 [0.98] 25 x 50 [0.98 x 1.97] 32 [ 1.26] 40 [1.57] 50 [1.97] M3 1 Accecatura Af3, DIN 74 MN05401010E MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 61 MN05401010E.qxd:MN05401010E 7/31/12 9:11 AM Page 62 Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 USA Eaton.com © 2012 Eaton Corporation All Rights Reserved Printed in USA Publication No. MN05401010E / Z12462 July 2012 Eaton is a registered trademark of Eaton Corporation. All trademarks are property of their respective owners.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

Eaton E5524E0402 Operating Instructions Manual

Tipo
Operating Instructions Manual

en otros idiomas