Burner input requirements
Elevations up to 10,000 ft (3,048 m):
• The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are net required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft (3,048 m}:
• When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner B.T.U. rating shown on the model/serial number
plate is required for each 1,000 ft (305 m) increase in
elevation.
Gas supply pressure testing
• The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2psi.
Dryer gas pipe
• The gas pipe that comes out through the rear of your dryer
has a %" male pipe thread.
*6¼" .........
(15.9 cm} ............
J 7T
_" 1½"
A (3.8ore)
A. _2" NPT gas supply line
B. _" NPT dryer pipe
*NOTE: Ifthe dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (25.4 cm) from the floor.
Fire Hazard
Use a heavy meta_ vent.
Do not use a p}astic vent.
Do not use a meta_ foi{ vent.
Failure to fo[}ow these instructions can result in death
or fire.
WARNING; To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
If using an existing vent system
• Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
• Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
• Review Vent length chart. Modify existing vent system if
necessary to achieve the best drying performance.
_t__ _;,,,,,,,,,,,,,,,,,,,,,,,,,,_,,,,_,_,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,J,_,__,,,
If this is a new vent system
Vent material
• Use a heavy metal vent. Do not use plastic or metal foil vent.
• 4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TM venting products are recommended.
4" (10.2 cm) heavy metalexhaust vent
DURASAFE TM vent products can be purchased from your
local Sears store or Sears Service Center. For more
information, call 1-800-4-MY-HOME _(1-800-469-4663}.
Rigid metal vent
• For best drying performance, rigid metal vents are
recommended.
• Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent
• Flexible metal vents are acceptable only if accessible for
cleaning.
• Flexible metal vent must be fully extended and supported
when the dryer is in its final position.
• Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
• Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbow provide better airflow than 90° elbows
Good Better
Clamps
• Use clamps to seal all joints.