ORBIT IRRIGATION 57471 El manual del propietario

Tipo
El manual del propietario
ENGLISH
Installation Instructions
Install the valve in seven easy steps—
1. Attach the Valves
2. Attach Sprinkler Lines
3. Run the Wire
4. Attach the Wire
5. Close the Sprinkler Valves
6. Test the System
7. Open the Valves
A
ttach the Valves
After flushing lines, install the valve to the manifold with an adapter or nipple (adapter or
nipple not required for Male Jar-Top valve). DO NOT OVERTIGHTEN. Do not use pipe
joining compound. Use thread seal tape only. Note arrow for water flow direction. Valves
have tapered fittings and therefore require seven to eight turns of thread seal tape to pre-
vent leaking and to guard against the connections bottoming out. To prevent possible
leaking, make sure that the manifold and pipe are properly aligned.
Attach Sprinkler Lines
Attach sprinkler lines to valve with an adapter (adapter or nipple not required for Male
Jar-Top valve).
RECOMMENDATION: Use Orbit’s Pre-Assembled Manifold to make the valve easier to
service or for future manifold modifications.
Run the Wire
With the power off, connect the valves to a an Orbit
®
timer (or any other timer that uses a
UL-approved 24-volt Class 2 transformer as a power source). Use a multi-colored, multi-
strand approved jacketed sprinkler wire. Be sure the wire has at least one more strand
than the number of valves in the manifold. Run the wire to the valves (usually in the same
trench as the sprinkler pipe).
RECOMMENDATION: Use a piece of PVC pipe as a protective covering for sprinkler wire
in areas of frequent digging.
A
ttach the Wire
Attach a colored wire to one valve wire on the solenoid and a common wire to the other
wire on the solenoid. It doesn’t matter which solenoid wire you use as the common.
Attach the colored wires to the corresponding zone terminal in the timer and the common
wire to the common connection in the timer. Use standard 20 gauge sprinkler wire for dis-
tances less than 800 feet (244 m). Use 18 gauge wire for distances over 800 feet (244 m).
Use an Orbit gr
ease cap and wire nut at each valve connection (See Figure A ). Also,
waterproof any splices made along the sprinkler wire.
C
lose the Sprinkler Valves
Turn the manual bleed lever clockwise until closed. When the water is turned on, the
valve will remain closed.
Test the System
After all pipe and fittings have been installed, turn the water supply on and check for
leaks with the valves closed.
O
pen the Valves
Turn the manual bleed lever/screw counterclockwise to manually open the valve. Then
close themanual bleed lever/scr
ew to shut the valve of
f. The system is now r
eady to be
controlled electrically from the timer or manually by opening the manual lever/screw.
Draining
In freezing areas, the valves and lines will need to be drained. Refer to the Orbit Layout
Guide or local dealer to recommend proper drain points. To insure the electric valve is
completely drained in the fall, turn off the main sprinkler shut-off valve and electrically
run each valve dry for a few minutes. Turn timer to the "OFF" position.
C
autions
Check local codes for valve types and per
mit infor
mation.
If static water pressure exceeds 80 psi, a pressure regulator should
be used.
For outdoor use with cold water only. Not for indoor use. Place valves so they drain
away fr
om the house.
Notes
Where possible, always protect valves with an Orbit Valve Box and place gravel in the
bottom.
Test all lines and fittings before burying the system.
Use a filter if you will not be using culinar
y water in your system.
Troubleshooting for Inline Valves
It is rare that your Orbit
®
low voltage electric valve will not operate as it should. If you do
have any pr
oblems, try the following solutions.
Limited 6 Y
ear W
arranty
Orbit
®
Irrigation Products, Inc. warrants to its customers that its Orbit
®
products will be free
from defects in materials and workmanship for a period of six years from date of purchase. We
will replace, free of charge, the defective part or parts found to be defective under normal use
and service for a period of up to six years after purchase (proof of purchase required). We reserve
the right to inspect the defective part prior to replacement. Orbit
®
Irrigation Products, Inc. will
not be responsible for consequential or incidental cost or damage caused by product failure.
Orbit
®
Irrigation Products, Inc.’s liability under this warranty is limited solely to the replacement
or repair of defective parts.
Pr
oblem: The valve will not open electrically
First, r
un the valve manually by opening the manual bleed lever/scr
ew (turn
counter
-clockwise). Close the manual bleed lever/scr
ew when manual test is complete.
Check if... Solution
1. The valve is installed incorrectly . . .
2. Wiring is incorrect. . . . . . . . . . . . . .
3. There is debris in the port hole . . . .
4. Defective solenoid . . . . . . . . . . . . . .
5. Solenoid plunger is stuck . . . . . . . .
Make sure that the arrows are in the direction of
water flow
.
Check wiring at the valve and at the timer with
the instructions Check to see that timer is work-
ing properly.
T
urn off water. Remove the solenoid. Push a wire
or large paper clip down through the round port
hole working it up and down to fr
ee any debris.
Be sure the plunger and O-ring are in place when
reassembling.
T
ur
n of
f water
. Unscrew the solenoid and replace
with one from a working valve. If the valve
works, replace the solenoid. Be sure the plunger
and O-ring are in place when reassembling.
Turn off water. Remove the solenoid and clean out
sand and debris. Be sur
e the plunger and O-ring
are in place when reassembling.
Pr
oblem: The valve will not close
Check if... Solution
1. The valve is installed incorrectly . . .
2. Solenoid plunger is stuck . . . . . . . .
3. Rock or debris is between the . . . . .
washer and the valve seat
4. Diaphragm has r
uptur
ed
. . . . . . . . .
Make sur
e that the ar
r
ows are in the direction of
water flow.
T
ur
n of
f water
. Remove the solenoid and clean out
sand and debris. Be sure the plunger and O-ring
are in place when reassembling.
T
ur
n off water. Remove valve lid and diaphragm
assembly and clean the interior of the valve.
Turn off water. Remove the lid and inspect the
diaphragm for tears. Replace the diaphragm
assembly if torn.
Pr
oblem: Exter
nal valve leaks
Check if... Solution
1. PVC fittings going into valve . . . . . .
installed incorrectly
2. Pressure is too high . . . . . . . . . . . . .
3. Leaking below solenoid . . . . . . . . . .
Use thread seal tape generously on threads and
tighten firmly. Do not over tighten.
Install a pr
essur
e r
egulator upstr
eam of the valve
and set at about 80 psi (5.5 bars).
Turn off water. Tighten solenoid.
Instrucciones de instalación
Instale la válvula siguiendo estos siete pasos–
1. Fije las válvulas
2. Fije las conducciones de los aspersores
3. Tienda el cable
4. Fíjelo
5. Cierre las válvulas del aspersor
6. Compruebe el sistema
7. Abra las válvulas
Fije las válvulas
Después de haber limpiado con una descarga de agua los conductos, instale la válvula en el
colector con un adaptador o acoplador (No se necesita un adaptador o boquilla para la
válvula tipo Jar-Top (de tapa superior de rosca). NO LO APRIETE DEMASIADO. No utilice
un compuesto para unir tubos. Utilice cinta adhesiva únicamente. Observe la flecha para ver
la dirección del flujo del agua. Las válvulas disponen de accesorios cónicos y por tanto es
necesario que se envuelvan siete u ocho veces con cinta adhesiva para impedir que haya
fugas y evitar que las conexiones sufran ningún golpe. Para evitar posibles goteos, verifique
que el distribuidor y el tubo estén adecuadamente alineados.
Fije los conductos del aspersor
Fije los conductos del aspersor a la válvula con un adaptador (No se necesita un adaptador o
boquilla para la válvula tipo Jar-Top (de tapa superior de rosca).
RECOMENDACIÓN: Utilice el colector de Orbit previamente montado para hacer que la
válvula sea más fácil de reparar o por si más adelante es necesario realizar modificaciones en
el colector.
Tienda el cable
Con el suministro eléctrico desconectado, conecte las válvulas a un programador Orbit
®
(u otro programador que utilice un transformador aprobado por UL (laboratorio de asegu-
radores) de 24 volt Clase 2 como fuente de alimentación eléctrica). Utilice un cable de asper-
sor de manguito de múltiples hebras y varios colores autorizado. Asegúrese que el cable tiene
una hebra más que el número de válvulas que hay en el colector. Tienda el cable a las válvu-
las (por lo general en la misma regata en la que se encuentra la tubería del aspersor).
RECOMENDACIÓN: Utilice un pedazo de tubería PVC como cubierta de protección para el
cable del aspersor en zonas donde se cave a menudo.
Fije el cable
Fije un cable de color a un cable de válvula en el solenoide y un cable normal en el otro
cable del solenoide. No importa que cable solenoide utilice como normal. Fije los cables de
colores a la zona terminal correspondiente del programador y el cable normal a la conexión
normal del programador. Utilice cable del aspersor estándar de espesor 20 para distancias de
menos de 800 feet (244 m). Utilice cable de calibre 18 para distancias de 244 metros. Utilice
una capsula de grasa y una tuerca para cables Orbit en cada conexión de válvula (Ver ilus-
tración A). Impermeabilice los empalmes que se hayan hecho a lo largo del cable del asper-
sor.
C
ier
r
e las válvulas del aspersor
Gire la palanca de purga manual en el sentido de las agujas del reloj hasta cerrarla. Cuando
fluya el agua, la válvula permanecerá cerrada.
C
ompruebe el sistema
Después de que se hayan instalado la tubería y los accesorios, abra el suministr
o de agua y
compr
uebe que no haya fugas con las válvulas cer
radas.
Abra las válvulas
Gir
e la palanca/el tor
nillo de pur
ga manual en sentido contrario a las agujas del reloj para
abrir la válvula manualmente. Luego cierre la palanca/el tornillo de purga manual para cerrar
la válvula. Ahora el sistema está listo para ser controlado eléctricamente desde el progra-
mador o manualmente si se abre el palanca/el tornillo de purga manual.
Drenaje
En áreas muy frías, las válvulas y los conductos necesitarán drenarse. Consulte la guía de dis-
tribución Orbit o a su proveedor para que le recomiende los puntos de drenaje adecuados.
Para asegurárse de que la válvula eléctrica está dr
enada completamente en otoño, desconecte
la válvula de cier
r
e del aspersor principal y haga funcionar sin lubricante cada válvula
durante unos minutos. Ponga el programador en la posición “OFF” (desconectado).
Precaución
Compr
uebe los códigos locales para los tipos de válvula e infor
maciones de per
miso.
Si la presión del agua en reposo es superior a 80 psi (5.5 bars), debería utilizar un
regulador de presión.
Sólo puede utilizarse en el exterior con agua fría. No se puede utilizar en el interior de
casa. Coloque las válvulas de modo que se dr
enen lejos de su casa.
Notas
Siempr
e que sea posible pr
oteja las válvulas con una caja para válvulas de Orbit y ponga
gravilla en el fondo.
Compruebe todos los conductos y accesorios antes de enterrar el sistema.
Utilice un filtr
o si no va a utilizar agua potable en el sistema.
Resolución de problemas para válvulas en línea
Es poco frecuente que la válvula de bajo voltaje eléctrico Orbit
®
no funcione
correctamente. Si tiene problemas, intente una de las siguientes soluciones.
SPANISH
Problema: La válvula no se abre automáticamente
Primero, ponga en marcha la válvula manualmente abriendo la palanca/el tornillo de
purga manual. (girando en sentido contrario a las agujas del reloj). Cierre la palanca/el
tornillo de purga manual cuando se haya completado el test manual.
Compruebe si... Solución
Pr
oblema: La válvula no se cierra
Compruebe si... Solución
1. La válvula no está instalada . . . . . .
correctamente
2. El pistón solenoide está atascado. . .
3.
Hay piedras o residuos entre la . . . .
arandela y el asiento de válvula
4. Se ha roto el diafragma . . . . . . . . . .
Asegúr
ese que las flechas se encuentran en la
dir
ección del flujo de agua.
Desconecte el agua. Retire el solenoide y limpie la
arena y los residuos. Asegúrese que el pistón y el
anillo en forma de O están en su sitio cuando
vuelva a colocar las piezas.
Desconecte el agua. Retir
e la cubier
ta de la válvula
y el ensamblaje de diafragma y limpie el interior
de la válvula.
Cier
r
e el agua. Retir
e la cubier
ta e inspeccione el
diafragma en busca de desgarros. Retire el ensam-
blaje del diafragma si se encuentra rasgado.
Pr
oblema: Fugas en las válvulas exter
nas
Compruebe si... Solución
1. Los accesorios PVC que van a la
. . .
1- válvula no están instalados correcta
mente
2. La presión es demasiado alta . . . . . .
3.
Hay una per
dida debajo del solenoide. .
Utilice una cinta adhesiva para sujetar firmemente las
r
oscas. No las sujete demasiado fuerte.
Instale un regulador de presión contracorriente de la
válvula y establezca una presión de 80 psi
(5.5 bars).
Cierre el agua. Apriete firmemente el solenoide.
Instructions d’installation
Pose de la vanne en sept étapes simples
1. Fixation des vannes
2. Raccordement des conduites d’arroseur
3. Traction du fil
4. Raccordement du fil
5. Fermeture des vannes d’arrosage
6. Mise à l’essai de l’installation
7. Ouverture des vannes
F
ixer les vannes
Après avoir rincé les conduites, installez la vanne sur le collecteur avec un adaptateur ou un
mamelon (Un adaptateur ou un raccord ne sont pas nécessaires pour la valve mâle du couvercle
de bocal). NE SERREZ PAS EXCESSIVEMENT. N’utilisez pas de pâte à joints. N’utilisez que du
ruban pour joints filetés. Notez l’orientation de la flèche; elle indique le sens d’écoulement de
l’eau. Les vannes ont des raccords coniques; appliquez-y sept à huit tours de ruban pour joints
filetés pour les étanchéiser et empêcher les connexions de buter en fin de course. Pour éviter
des fuites possibles, s’assurer que le collecteur et le tuyau sont alignés correctement.
R
accordement des conduites d’arroseur
Raccordez les conduites d’arroseur à la vanne avec un adaptateur (Un adaptateur ou un
raccord ne sont pas nécessaires pour la valve mâle du couvercle de bocal).
RECOMMANDATION: Utilisez un collecteur préassemblé Orbit, pour faciliter l’entretien de la
vanne ou pouvoir modifier ultérieurement le collecteur.
T
raction du fil
Après avoir coupé l’alimentation électrique, connectez les vannes à un programmateur Orbit
®
(ou à tout autre programmateur alimenté par un transformateur 24 V catégorie 2 agréé UL).
Utilisez un fil à arroseur multicolore, à plusieurs torons, gainé et agrée. Assurez-vous que le fil
comporte au moins un toron de plus que le nombre de vannes du collecteur. Tirez le fil
jusqu’aux vannes (généralement dans la même tranchée que la tuyauterie d’arroseur).
RECOMMANDATION: Utilisez du tuyau en PCV pour protéger le fil à arroseur dans les zones
où l’on creuse fréquemment.
Raccordement du fil
Raccordez un fil coloré à une extrémité du solénoïde de la vanne et un conducteur neutre à
l’autre extrémité du solénoïde. On peut utiliser n’importe quel fil du solénoïde comme con-
ducteur neutre. Raccordez les fils colorés à la borne de zone correspondante du programma-
teur, et le conducteur neutre, à la borne neutre du programmateur. Utilisez du fil à arroseur
standard de calibre 20 pour les distances inférieures à 800 pieds (244 m). Utilisez du fil de
calibre 18 pour les distances supérieures à 800 pieds. Utilisez un capuchon de graisse Orbit et
une connexion à chaque connexion de la vanne
(Voir Figure A ). De plus, étanchéisez toute jonction réalisée sur le fil à arroseur.
Fermeture des vannes d’arrosage
Tournez le levier manuel de purge dans le sens des aiguilles d'une montre jusqu'à ce qu'il soit
fermé. Lorsqu’on rétablit l’alimentation d’eau, la vanne reste fermée.
Mise à l’essai de l’installation
Après avoir posé tous les tuyaux et tous les raccords, rétablissez l’alimentation d’eau et décelez
toute fuite lors de la fermeture des vannes.
Ouvrir les vannes
T
ournez le levier/vis manuel de purge en sens inverse des aiguilles d'une montre pour ouvrir
manuellement la valve. Ensuite fermez le levier/vis manuel de purge pour fermer la valve. Le
circuit est à présent prêt à être commandé électriquement à partir du programmateur ou
manuellement en desserrant la levier/vis de purge manuelle.
Pur
ge
Dans les zones où la température baisse au-dessous du point de congélation, on doit purger les
vannes et les conduites. Consultez le guide de disposition Orbit ou le détaillant de la localité
au sujet des points de purge recommandés. En automne, pour s’assurer que l’électrovanne est
complètement purgée, fermez le robinet principal des arroseurs et faites fonctionner électrique-
ment chaque vanne, à sec, pendant quelques minutes. Mettez le pr
ogrammateur sur
“ARRÊT”.
Mises en garde
Consulter les codes locaux pour les types de vannes et tout r
enseignement r
elatif aux per
mis.
Si la pression statique de l’eau dépasse 80 psi (5.5 bars), l’utilisation d’un régulateur de
pr
ession est r
ecommandée.
• À utiliser à l’extérieur, avec une alimentation d’eau froide uniquement. Ne pas utiliser à l’in-
t
érieur. Disposez les vannes de manière à ce que la purge se fasse en direction opposée de la
maison.
Remar
ques
Si possible, protégez toujours les vannes par une boîte à vanne Orbit, en plaçant du gravier
au fond.
Testez toutes les conduites et tous les raccords avant d’enterrer le circuit.
Utilisez un filtre si le circuit n’est pas alimenté avec de l’eau potable.
Dépannage des vannes en ligne
Il est rar
e qu’une électr
ovanne basse tension Orbit
®
fonctionne mal. En cas de pr
oblème,
essayez les solutions suivantes.
FRANCAIS
Problème: La vanne ne s’ouvre pas électriquement.
D'abord, manœuvrez la valve manuellement en ouvrant le levier/vis manuel de purge.
(tournez la levier/vis de purge manuelle dans le sens contraire des aiguilles). Fermez le
levier/vis manuel de purge quand le test manuel est terminé.
1. La vanne est correctement posée . . .
2. Le câblage est satisfaisant. . . . . . . . .
3.
Il y a des débris dans l’orifice . . . . .
circulaire
4. Le solénoïde est défectueux . . . . . . .
5. Le plongeur du solénoïde est bloqué
Assur
ez-vous que les flèches indiquent le sens d’é
-
coulement de l’eau.
Vérifiez-le au niveau de la vanne et du pr
ogram
-
mateur pour vous assur
er qu’il est confor
me aux
instructions. Assurez-vous que le programmateur
fonctionne cor
r
ectement.
Coupez l’eau. Retirez le solénoïde. Introduisez un
fil ou un grand trombone par l’orifice circulaire et,
d’un mouvement de va et vient, enlevez tous les
débris. Assurez-vous que le plongeur et le joint
torique sont à leur place lors du remontage.
Coupez l’eau. Dévissez le solénoïde et r
emplacez-le
par celui d’une vanne en bon état. Si la vanne
fonctionne, r
eplacez le solénoïde. Assur
ez-vous
que le plongeur et le joint torique sont à leur place
lors du remontage.
Coupez l’eau. Retir
ez le solénoïde et enlevez sable
et débris. Assurez-vous que le plongeur et le joint
torique sont à leur place lors du r
emontage.
Problème: La vanne ne se ferme pas
Vérifiez si... Solution
1. La vanne est cor
rectement posée . . .
2. Le plongeur du solénoïde est bloqué
3. Une pier
r
e ou des débris sont pris . .
entre la rondelle et le siège de la
vanne
4. La membrane s’est déchirée . . . . . . .
Assurez-vous que les flèches indiquent le sens d’é-
coulement de l’eau.
Coupez l’eau. Retir
ez le solénoïde et enlevez sable
et débris. Assurez-vous que le plongeur et le joint
torique sont à leur place lors du remontage.
Coupez l’eau. Retir
ez le couver
cle de la vanne et la
membrane, et nettoyez l’intérieur de la vanne.
Coupez l’eau. Retirez le couvercle et décelez toute
déchir
ure de membrane. Remplacez la membrane
en cas de déchirure.
Problème: Fuites à l’extérieur de la vanne
Vérifiez si...
Solution
1. Les raccords en PCV qui entrent dans
1- la vanne sont correctement posés
2. La pr
ession est excessive
. . . . . . . . .
3. Fuites sous le solénoïde
. . . . . . . . . .
Posez une bonne quantité de r
uban pour joints
filetés sur les filets et serrez fermement. Ne serrez
pas excessivement.
Installez un régulateur de pression en amont de la
vanne et réglez-le à environ.
Coupez l’eau. Serrez le solénoïde.
Parts Listing
L
istado de piezas
Liste des pièces
C
aractéristiques électriques minimales: 18 V
c.a. au solénoïde.
Puissance d’appel
@24 V c.a. - 8,5 VA
C
ourant d’appel @24 V c.a. - 0,35 A
P
uissance de maintien @24 V c.a. - 5,5 VA
Courant de maintien
@24 V c.a. - 0,23 A
1
2
3
4
5
6
7
8
9
5 10 15 20 25 30 35
Friction Loss Chart
For In-Line V
alve
Flow Rate - GPM
Velocidad de flujo - GPM
Débit (gal/min)
Pressure Loss - psi
Perdida de presión - psi
Perte de pression (kg/cm2)
Gráfica de perdidas por fricción
para válvula en línea
T
ableau des pertes de charge par frottement
des vannes en ligne
Se requiere un voltaje de 18 Volts CA como
m
ínimo en el solenoide.
V
olt-amps de entrada
@24 V
AC - 8,5 VA
Corriente de entrada @24 VAC - 0,35 AMPS
Volt-amps de retención @24 VAC - 5,5 VA
Corriente de retención
@24 V
AC - 0,23
AMPS
Always check local codes before installing any sprinkler system.
Arrow indicates direction of water flow.
If static water pressure exceeds 80 psi (5.5 bars), a pressure regulator
should be used.
Compruebe siempre los códigos locales antes de instalar un sis-
tema de riego por aspersión.
La flecha indica la dirección del flujo del agua.
Si la presión del agua en reposo es superior a 80 psi (5.5 bars),
debe utilizarse un regulador de presión.
Consultez toujours les codes locaux avant d’installer un arroseur.
La flèche indique le sens d’écoulement de l’eau.
Si la pression d’eau statique dépasse, l’utilisation d’un régulateur
de pression est recommandée.
Figure A
Ilustración A
F
igure A
Garantía limitada de 6 años
Orbit
®
Irrigation Products, Inc. garantiza a sus clientes que sus productos Orbit
®
están protegidos
contra cualquier defecto de fabricación durante un periodo de seises años a contar a partir de la
fecha de compra. Le cambiaremos, sin ningún gasto adicional, la pieza o piezas defectuosas
durante un periodo de seises años a partir de la fecha de compra (es necesario presentar el docu-
mento que certifique la compra). Nos reservamos el derecho de inspeccionar la pieza defectuosa
antes de proceder a su sustitución. Orbit
®
Irrigation Products, Inc. no se hace responsable de los
gastos incidentales o derivados ni de los daños producidos por defectos del producto. La respon-
sabilidad de Orbit
®
Irrigation Products, Inc. según esta garantía se limita únicamente a la sustitu-
ción o reparación de las piezas defectuosas.
Garantie limitée de 6 ans
Orbit
®
Ir
rigation Pr
oducts, Inc. garantit à ses clients ses pr
oduits Orbit
®
contr
e tout défaut de
matièr
e et de fabrication, et ce pendant six ans à compter de la date d’achat. La société s’engage à
r
emplacer
, gratuitement, la ou les pièces qui se révéleraient défectueuses dans des conditions d’u
-
tilisation et de fonctionnement nor
males pendant au plus six ans à compter de l’achat (pr
euve
d’achat exigée). La société se réser
ve le dr
oit d’inspecter toute pièce défectueuse avant de la r
em
-
placer
. Orbit
®
Ir
rigation Pr
oducts, Inc. décline toute r
esponsabilité en matièr
e de frais ou de
dommages dir
ects ou indir
ects imputables à une défaillance de ses pr
oduits. En ver
tu de la
présente garantie, la r
esponsabilité d’Orbit
®
Ir
rigation Pr
oducts, Inc. se limite exclusivement au
r
emplacement ou à la réparation des pièces défectueuses.
A Ring
Anillo
Baque
B Solenoid
Solenoide
Solénoïde
C Internal Bleed lever
Palanca de purga
Levier de purge
D Solenoid Plunger
P
istón de solenoide
Tige du solénoïde
E Solenoid O-Ring
Anillo en form a de O solenoide
Joint du solénoïde
F V
alve Lid Assembly
Ensamblaje de la cubierta de la válvula
Couvercle de la vanne
G Spring
Muelle
Ressort
H Diaphragm Assembly
Ensamblaje de diafragma
Membrane
I Diaphragm Support Ring
Anillo de soporte de diafragma
Bague d'appui de la membrane
J S.S. Tube
S.S. Tubo
Tube en acier inox
K V
alve Body
Cuerpo de válvula
Corps de vanne
L Bleed Screw
Tornillos de purga
Vis de purge
A To Timer
Al programador
Vers le programmateur
B Common Wire Out T
o Timer
Cable Común que va al programador
rizador Fil neutre de sortie vers le pro-
grammateur
C Grease Cap
C
apuchon
Capuchon de graisse
D Valve Common Wires
Cables comunes de válvula
Fils neutres de la vanne
E T
o Sprinkler Heads
A los cabezales del aspersor
Vers les têtes d'arroseur
F Main Sprinkler Water Line
Conducción de agua del aspersor principal
C
onduite d'alimentation d'eau de l'arroseur
principal
Electrical requirements are 18 Volts AC
minimum at the solenoid.
I
nrush volt-amps
@
24 V
AC - 8.5 V
A
I
nrush current @24 VAC - .35 AMPS
Holding volt-amps @24 VAC - 5.5 VA
Holding current @24 VAC - .23 AMPS
B
C
A
F
H
G
I
J
K
D
E
1. La válvula no está instalada . . . . . .
correctamente
2. El cableado no es correcto. . . . . . . .
3. Hay r
esiduos en la aber
tura de entra
da y salida de la válvula
. . . . . . . . .
4.
Solenoide defectuoso . . . . . . . . . . . .
5. El pistón de solenoide está atascado. .
Asegúr
ese que las flechas se encuentran en la
dirección del flujo de agua.
Compr
uebe el cableado de la válvula y del pr
ogra
-
mador con las instr
ucciones. Compr
uebe que el
programador funciona correctamente.
Cier
re el agua. Retire el solenoide. Con un alambre
o un clip extraiga moviendo de ar
riba abajo los
residuos que se encuentran alrededor de la abertu-
ra de entrada y salida de la válvula. Asegúr
ese que
el pistón y el anillo en forma de O están en su sitio
cuando vuelva a colocar las piezas.
Cier
r
e el agua. Destornille el solenoide y sustitúya-
lo por uno de la válvula de maniobra. Si la válvula
funciona, sustituya el solenoide. Asegúr
ese que el
pistón y el anillo en forma de O están en su sitio
cuando vuelva a colocar las piezas.
Cier
r
e el agua. Retire el solenoide y limpie la arena
y los residuos. Asegúrese que el pistón y el anillo
en for
ma de O están en su sitio cuando vuelva a
colocar las piezas.
A
B
D
E
F
C
O
rbit
®
L
07WTM002681 57470-30 rG.qxd 3/26/07 4:22 PM Page 2

Transcripción de documentos

07WTM002681 57470-30 rG.qxd 3/26/07 4:22 PM Page 2 • Always check local codes before installing any sprinkler system. • Arrow indicates direction of water flow. • If static water pressure exceeds 80 psi (5.5 bars), a pressure regulator should be used. • Compruebe siempre los códigos locales antes de instalar un sistema de riego por aspersión. • La flecha indica la dirección del flujo del agua. • Si la presión del agua en reposo es superior a 80 psi (5.5 bars), debe utilizarse un regulador de presión. • Consultez toujours les codes locaux avant d’installer un arroseur. • La flèche indique le sens d’écoulement de l’eau. ENGLISH SPANISH FRANCAIS Installation Instructions Instrucciones de instalación Instructions d’installation Install the valve in seven easy steps— Instale la válvula siguiendo estos siete pasos– Pose de la vanne en sept étapes simples 1. Attach the Valves 2. Attach Sprinkler Lines 3. Run the Wire 4. Attach the Wire 5. Close the Sprinkler Valves 6. Test the System 7. Open the Valves 1. Fije las válvulas 2. Fije las conducciones de los aspersores 3. Tienda el cable 4. Fíjelo 5. Cierre las válvulas del aspersor 6. Compruebe el sistema 7. Abra las válvulas 1. Fixation des vannes 2. Raccordement des conduites d’arroseur 3. Traction du fil 4. Raccordement du fil 5. Fermeture des vannes d’arrosage 6. Mise à l’essai de l’installation 7. Ouverture des vannes Attach the Valves Fije las válvulas Fixer les vannes Después de haber limpiado con una descarga de agua los conductos, instale la válvula en el colector con un adaptador o acoplador (No se necesita un adaptador o boquilla para la válvula tipo Jar-Top (de tapa superior de rosca). NO LO APRIETE DEMASIADO. No utilice un compuesto para unir tubos. Utilice cinta adhesiva únicamente. Observe la flecha para ver la dirección del flujo del agua. Las válvulas disponen de accesorios cónicos y por tanto es necesario que se envuelvan siete u ocho veces con cinta adhesiva para impedir que haya fugas y evitar que las conexiones sufran ningún golpe. Para evitar posibles goteos, verifique que el distribuidor y el tubo estén adecuadamente alineados. Après avoir rincé les conduites, installez la vanne sur le collecteur avec un adaptateur ou un mamelon (Un adaptateur ou un raccord ne sont pas nécessaires pour la valve mâle du couvercle de bocal). NE SERREZ PAS EXCESSIVEMENT. N’utilisez pas de pâte à joints. N’utilisez que du ruban pour joints filetés. Notez l’orientation de la flèche; elle indique le sens d’écoulement de l’eau. Les vannes ont des raccords coniques; appliquez-y sept à huit tours de ruban pour joints filetés pour les étanchéiser et empêcher les connexions de buter en fin de course. Pour éviter des fuites possibles, s’assurer que le collecteur et le tuyau sont alignés correctement. After flushing lines, install the valve to the manifold with an adapter or nipple (adapter or nipple not required for Male Jar-Top valve). DO NOT OVERTIGHTEN. Do not use pipe joining compound. Use thread seal tape only. Note arrow for water flow direction. Valves have tapered fittings and therefore require seven to eight turns of thread seal tape to prevent leaking and to guard against the connections bottoming out. To prevent possible leaking, make sure that the manifold and pipe are properly aligned. • Si la pression d’eau statique dépasse, l’utilisation d’un régulateur de pression est recommandée. Figure A Ilustración A Figure A Attach Sprinkler Lines Attach sprinkler lines to valve with an adapter (adapter or nipple not required for Male Jar-Top valve). RECOMMENDATION: Use Orbit’s Pre-Assembled Manifold to make the valve easier to service or for future manifold modifications. Run the Wire With the power off, connect the valves to a an Orbit® timer (or any other timer that uses a UL-approved 24-volt Class 2 transformer as a power source). Use a multi-colored, multistrand approved jacketed sprinkler wire. Be sure the wire has at least one more strand than the number of valves in the manifold. Run the wire to the valves (usually in the same trench as the sprinkler pipe). RECOMMENDATION: Use a piece of PVC pipe as a protective covering for sprinkler wire in areas of frequent digging. D A Attach the Wire Attach a colored wire to one valve wire on the solenoid and a common wire to the other wire on the solenoid. It doesn’t matter which solenoid wire you use as the common. Attach the colored wires to the corresponding zone terminal in the timer and the common wire to the common connection in the timer. Use standard 20 gauge sprinkler wire for distances less than 800 feet (244 m). Use 18 gauge wire for distances over 800 feet (244 m). Use an Orbit grease cap and wire nut at each valve connection (See Figure A ). Also, waterproof any splices made along the sprinkler wire. B C Close the Sprinkler Valves Turn the manual bleed lever clockwise until closed. When the water is turned on, the valve will remain closed. E Test the System After all pipe and fittings have been installed, turn the water supply on and check for leaks with the valves closed. Open the Valves F Turn the manual bleed lever/screw counterclockwise to manually open the valve. Then close themanual bleed lever/screw to shut the valve off. The system is now ready to be controlled electrically from the timer or manually by opening the manual lever/screw. A To Timer Al programador Vers le programmateur D Valve Common Wires Cables comunes de válvula Fils neutres de la vanne B Common Wire Out To Timer Cable Común que va al programador rizador Fil neutre de sortie vers le programmateur E To Sprinkler Heads A los cabezales del aspersor Vers les têtes d'arroseur C F Grease Cap Capuchon Capuchon de graisse Draining Main Sprinkler Water Line Conducción de agua del aspersor principal Conduite d'alimentation d'eau de l'arroseur principal In freezing areas, the valves and lines will need to be drained. Refer to the Orbit Layout Guide or local dealer to recommend proper drain points. To insure the electric valve is completely drained in the fall, turn off the main sprinkler shut-off valve and electrically run each valve dry for a few minutes. Turn timer to the "OFF" position. A Notes C D Solenoid Plunger Pistón de solenoide Tige du solénoïde I Orbit Valve Lid Assembly Ensamblaje de la cubierta de la válvula Couvercle de la vanne J K L Spring Muelle Ressort J It is rare that your Orbit® low voltage electric valve will not operate as it should. If you do have any problems, try the following solutions. K Problem: The valve will not open electrically ® First, run the valve manually by opening the manual bleed lever/screw (turn counter-clockwise). Close the manual bleed lever/screw when manual test is complete. Friction Loss Chart For In-Line Valve Gráfica de perdidas por fricción para válvula en línea Tableau des pertes de charge par frottement Con el suministro eléctrico desconectado, conecte las válvulas a un programador Orbit® (u otro programador que utilice un transformador aprobado por UL (laboratorio de aseguradores) de 24 volt Clase 2 como fuente de alimentación eléctrica). Utilice un cable de aspersor de manguito de múltiples hebras y varios colores autorizado. Asegúrese que el cable tiene una hebra más que el número de válvulas que hay en el colector. Tienda el cable a las válvulas (por lo general en la misma regata en la que se encuentra la tubería del aspersor). RECOMENDACIÓN: Utilice un pedazo de tubería PVC como cubierta de protección para el cable del aspersor en zonas donde se cave a menudo. Fije el cable Fije un cable de color a un cable de válvula en el solenoide y un cable normal en el otro cable del solenoide. No importa que cable solenoide utilice como normal. Fije los cables de colores a la zona terminal correspondiente del programador y el cable normal a la conexión normal del programador. Utilice cable del aspersor estándar de espesor 20 para distancias de menos de 800 feet (244 m). Utilice cable de calibre 18 para distancias de 244 metros. Utilice una capsula de grasa y una tuerca para cables Orbit en cada conexión de válvula (Ver ilustración A). Impermeabilice los empalmes que se hayan hecho a lo largo del cable del aspersor. Cierre las válvulas del aspersor Gire la palanca de purga manual en el sentido de las agujas del reloj hasta cerrarla. Cuando fluya el agua, la válvula permanecerá cerrada. Compruebe el sistema Después de que se hayan instalado la tubería y los accesorios, abra el suministro de agua y compruebe que no haya fugas con las válvulas cerradas. Abra las válvulas Gire la palanca/el tornillo de purga manual en sentido contrario a las agujas del reloj para abrir la válvula manualmente. Luego cierre la palanca/el tornillo de purga manual para cerrar la válvula. Ahora el sistema está listo para ser controlado eléctricamente desde el programador o manualmente si se abre el palanca/el tornillo de purga manual. Check if... Solution En áreas muy frías, las válvulas y los conductos necesitarán drenarse. Consulte la guía de distribución Orbit o a su proveedor para que le recomiende los puntos de drenaje adecuados. Para asegurárse de que la válvula eléctrica está drenada completamente en otoño, desconecte la válvula de cierre del aspersor principal y haga funcionar sin lubricante cada válvula durante unos minutos. Ponga el programador en la posición “OFF” (desconectado). Precaución • Compruebe los códigos locales para los tipos de válvula e informaciones de permiso. • Si la presión del agua en reposo es superior a 80 psi (5.5 bars), debería utilizar un regulador de presión. • Sólo puede utilizarse en el exterior con agua fría. No se puede utilizar en el interior de casa. Coloque las válvulas de modo que se drenen lejos de su casa. Raccordez les conduites d’arroseur à la vanne avec un adaptateur (Un adaptateur ou un raccord ne sont pas nécessaires pour la valve mâle du couvercle de bocal). RECOMMANDATION: Utilisez un collecteur préassemblé Orbit, pour faciliter l’entretien de la vanne ou pouvoir modifier ultérieurement le collecteur. Traction du fil Après avoir coupé l’alimentation électrique, connectez les vannes à un programmateur Orbit® (ou à tout autre programmateur alimenté par un transformateur 24 V catégorie 2 agréé UL). Utilisez un fil à arroseur multicolore, à plusieurs torons, gainé et agrée. Assurez-vous que le fil comporte au moins un toron de plus que le nombre de vannes du collecteur. Tirez le fil jusqu’aux vannes (généralement dans la même tranchée que la tuyauterie d’arroseur). RECOMMANDATION: Utilisez du tuyau en PCV pour protéger le fil à arroseur dans les zones où l’on creuse fréquemment. Raccordement du fil Raccordez un fil coloré à une extrémité du solénoïde de la vanne et un conducteur neutre à l’autre extrémité du solénoïde. On peut utiliser n’importe quel fil du solénoïde comme conducteur neutre. Raccordez les fils colorés à la borne de zone correspondante du programmateur, et le conducteur neutre, à la borne neutre du programmateur. Utilisez du fil à arroseur standard de calibre 20 pour les distances inférieures à 800 pieds (244 m). Utilisez du fil de calibre 18 pour les distances supérieures à 800 pieds. Utilisez un capuchon de graisse Orbit et une connexion à chaque connexion de la vanne (Voir Figure A ). De plus, étanchéisez toute jonction réalisée sur le fil à arroseur. Fermeture des vannes d’arrosage Tournez le levier manuel de purge dans le sens des aiguilles d'une montre jusqu'à ce qu'il soit fermé. Lorsqu’on rétablit l’alimentation d’eau, la vanne reste fermée. Mise à l’essai de l’installation Après avoir posé tous les tuyaux et tous les raccords, rétablissez l’alimentation d’eau et décelez toute fuite lors de la fermeture des vannes. Ouvrir les vannes Tournez le levier/vis manuel de purge en sens inverse des aiguilles d'une montre pour ouvrir manuellement la valve. Ensuite fermez le levier/vis manuel de purge pour fermer la valve. Le circuit est à présent prêt à être commandé électriquement à partir du programmateur ou manuellement en desserrant la levier/vis de purge manuelle. Purge Dans les zones où la température baisse au-dessous du point de congélation, on doit purger les vannes et les conduites. Consultez le guide de disposition Orbit ou le détaillant de la localité au sujet des points de purge recommandés. En automne, pour s’assurer que l’électrovanne est complètement purgée, fermez le robinet principal des arroseurs et faites fonctionner électriquement chaque vanne, à sec, pendant quelques minutes. Mettez le programmateur sur “ARRÊT”. Mises en garde • Consulter les codes locaux pour les types de vannes et tout renseignement relatif aux permis. • Si la pression statique de l’eau dépasse 80 psi (5.5 bars), l’utilisation d’un régulateur de pression est recommandée. • À utiliser à l’extérieur, avec une alimentation d’eau froide uniquement. Ne pas utiliser à l’intérieur. Disposez les vannes de manière à ce que la purge se fasse en direction opposée de la maison. Remarques Notas • Siempre que sea posible proteja las válvulas con una caja para válvulas de Orbit y ponga gravilla en el fondo. • Compruebe todos los conductos y accesorios antes de enterrar el sistema. • Utilice un filtro si no va a utilizar agua potable en el sistema. Resolución de problemas para válvulas en línea 1. The valve is installed incorrectly . . . Make sure that the arrows are in the direction of water flow. Es poco frecuente que la válvula de bajo voltaje eléctrico Orbit® no funcione correctamente. Si tiene problemas, intente una de las siguientes soluciones. 2. Wiring is incorrect. . . . . . . . . . . . . . Check wiring at the valve and at the timer with the instructions Check to see that timer is working properly. Problema: La válvula no se abre automáticamente • Si possible, protégez toujours les vannes par une boîte à vanne Orbit, en plaçant du gravier au fond. • Testez toutes les conduites et tous les raccords avant d’enterrer le circuit. • Utilisez un filtre si le circuit n’est pas alimenté avec de l’eau potable. Dépannage des vannes en ligne Il est rare qu’une électrovanne basse tension Orbit® fonctionne mal. En cas de problème, essayez les solutions suivantes. des vannes en ligne 9 Diaphragm Assembly Ensamblaje de diafragma Membrane Diaphragm Support Ring Anillo de soporte de diafragma Bague d'appui de la membrane 8 7 6 5 3. There is debris in the port hole . . . . Turn off water. Remove the solenoid. Push a wire or large paper clip down through the round port hole working it up and down to free any debris. Be sure the plunger and O-ring are in place when reassembling. 4 3 2 1 S.S. Tube S.S. Tubo Tube en acier inox 5 10 15 20 25 30 35 Flow Rate - GPM Velocidad de flujo - GPM Débit (gal/min) Valve Body Cuerpo de válvula Corps de vanne 4. Defective solenoid . . . . . . . . . . . . . . Turn off water. Unscrew the solenoid and replace with one from a working valve. If the valve works, replace the solenoid. Be sure the plunger and O-ring are in place when reassembling. 5. Solenoid plunger is stuck . . . . . . . . Turn off water. Remove the solenoid and clean out sand and debris. Be sure the plunger and O-ring are in place when reassembling. Bleed Screw Tornillos de purga Vis de purge Electrical requirements are 18 Volts AC minimum at the solenoid. Inrush volt-amps Inrush current Holding volt-amps Holding current Troubleshooting for Inline Valves G H F I • Where possible, always protect valves with an Orbit Valve Box and place gravel in the bottom. • Test all lines and fittings before burying the system. • Use a filter if you will not be using culinary water in your system. F Internal Bleed lever Palanca de purga Levier de purge Solenoid O-Ring Anillo en form a de O solenoide Joint du solénoïde H C A E G L E Solenoid Solenoide Solénoïde Pressure Loss - psi Perdida de presión - psi Perte de pression (kg/cm2) B B Tienda el cable Drenaje • Check local codes for valve types and permit information. • If static water pressure exceeds 80 psi, a pressure regulator should be used. • For outdoor use with cold water only. Not for indoor use. Place valves so they drain away from the house. D Fije los conductos del aspersor a la válvula con un adaptador (No se necesita un adaptador o boquilla para la válvula tipo Jar-Top (de tapa superior de rosca). RECOMENDACIÓN: Utilice el colector de Orbit previamente montado para hacer que la válvula sea más fácil de reparar o por si más adelante es necesario realizar modificaciones en el colector. Cautions Parts Listing Listado de piezas Liste des pièces Ring Anillo Baque Raccordement des conduites d’arroseur Fije los conductos del aspersor Se requiere un voltaje de 18 Volts CA como mínimo en el solenoide. @24 VAC - 8.5 VA @24 VAC - .35 AMPS @24 VAC - 5.5 VA @24 VAC - .23 AMPS Volt-amps de entrada Corriente de entrada Volt-amps de retención Corriente de retención @24 VAC - 8,5 VA @24 VAC - 0,35 AMPS @24 VAC - 5,5 VA @24 VAC - 0,23 AMPS Caractéristiques électriques minimales: 18 V c.a. au solénoïde. Puissance d’appel Courant d’appel Puissance de maintien Courant de maintien @24 V c.a. - 8,5 VA @24 V c.a. - 0,35 A @24 V c.a. - 5,5 VA @24 V c.a. - 0,23 A Limited 6 Year Warranty Orbit® Irrigation Products, Inc. warrants to its customers that its Orbit® products will be free from defects in materials and workmanship for a period of six years from date of purchase. We will replace, free of charge, the defective part or parts found to be defective under normal use and service for a period of up to six years after purchase (proof of purchase required). We reserve the right to inspect the defective part prior to replacement. Orbit® Irrigation Products, Inc. will not be responsible for consequential or incidental cost or damage caused by product failure. Orbit® Irrigation Products, Inc.’s liability under this warranty is limited solely to the replacement or repair of defective parts. Garantía limitada de 6 años Orbit® Irrigation Products, Inc. garantiza a sus clientes que sus productos Orbit® están protegidos contra cualquier defecto de fabricación durante un periodo de seises años a contar a partir de la fecha de compra. Le cambiaremos, sin ningún gasto adicional, la pieza o piezas defectuosas durante un periodo de seises años a partir de la fecha de compra (es necesario presentar el documento que certifique la compra). Nos reservamos el derecho de inspeccionar la pieza defectuosa antes de proceder a su sustitución. Orbit® Irrigation Products, Inc. no se hace responsable de los gastos incidentales o derivados ni de los daños producidos por defectos del producto. La responsabilidad de Orbit® Irrigation Products, Inc. según esta garantía se limita únicamente a la sustitución o reparación de las piezas defectuosas. Garantie limitée de 6 ans Orbit® Irrigation Products, Inc. garantit à ses clients ses produits Orbit® contre tout défaut de matière et de fabrication, et ce pendant six ans à compter de la date d’achat. La société s’engage à remplacer, gratuitement, la ou les pièces qui se révéleraient défectueuses dans des conditions d’utilisation et de fonctionnement normales pendant au plus six ans à compter de l’achat (preuve d’achat exigée). La société se réserve le droit d’inspecter toute pièce défectueuse avant de la remplacer. Orbit® Irrigation Products, Inc. décline toute responsabilité en matière de frais ou de dommages directs ou indirects imputables à une défaillance de ses produits. En vertu de la présente garantie, la responsabilité d’Orbit® Irrigation Products, Inc. se limite exclusivement au remplacement ou à la réparation des pièces défectueuses. Problem: The valve will not close Check if... Solution 1. The valve is installed incorrectly . . . Make sure that the arrows are in the direction of water flow. 2. Solenoid plunger is stuck . . . . . . . . Turn off water. Remove the solenoid and clean out sand and debris. Be sure the plunger and O-ring are in place when reassembling. 3. Rock or debris is between the . . . . . Turn off water. Remove valve lid and diaphragm washer and the valve seat assembly and clean the interior of the valve. 4. Diaphragm has ruptured . . . . . . . . . Turn off water. Remove the lid and inspect the diaphragm for tears. Replace the diaphragm assembly if torn. Problem: External valve leaks Check if... Solution D'abord, manœuvrez la valve manuellement en ouvrant le levier/vis manuel de purge. (tournez la levier/vis de purge manuelle dans le sens contraire des aiguilles). Fermez le levier/vis manuel de purge quand le test manuel est terminé. Compruebe si... 1. La vanne est correctement posée . . . Assurez-vous que les flèches indiquent le sens d’écoulement de l’eau. 2. Le câblage est satisfaisant. . . . . . . . . Vérifiez-le au niveau de la vanne et du programmateur pour vous assurer qu’il est conforme aux instructions. Assurez-vous que le programmateur fonctionne correctement. 3. Leaking below solenoid . . . . . . . . . . Turn off water. Tighten solenoid. Solución 1. La válvula no está instalada . . . . . . correctamente Asegúrese que las flechas se encuentran en la dirección del flujo de agua. 2. El cableado no es correcto. . . . . . . . Compruebe el cableado de la válvula y del programador con las instrucciones. Compruebe que el programador funciona correctamente. 3. Hay residuos en la abertura de entra Cierre el agua. Retire el solenoide. Con un alambre da y salida de la válvula . . . . . . . . . o un clip extraiga moviendo de arriba abajo los residuos que se encuentran alrededor de la abertura de entrada y salida de la válvula. Asegúrese que el pistón y el anillo en forma de O están en su sitio cuando vuelva a colocar las piezas. 4. Solenoide defectuoso . . . . . . . . . . . . Cierre el agua. Destornille el solenoide y sustitúyalo por uno de la válvula de maniobra. Si la válvula funciona, sustituya el solenoide. Asegúrese que el pistón y el anillo en forma de O están en su sitio cuando vuelva a colocar las piezas. 5. El pistón de solenoide está atascado. . Cierre el agua. Retire el solenoide y limpie la arena y los residuos. Asegúrese que el pistón y el anillo en forma de O están en su sitio cuando vuelva a colocar las piezas. Problema: La válvula no se cierra Compruebe si... Solución 1. La válvula no está instalada . . . . . . correctamente Asegúrese que las flechas se encuentran en la dirección del flujo de agua. 2. El pistón solenoide está atascado. . . Desconecte el agua. Retire el solenoide y limpie la arena y los residuos. Asegúrese que el pistón y el anillo en forma de O están en su sitio cuando vuelva a colocar las piezas. 1. PVC fittings going into valve . . . . . . Use thread seal tape generously on threads and installed incorrectly tighten firmly. Do not over tighten. 2. Pressure is too high . . . . . . . . . . . . . Install a pressure regulator upstream of the valve and set at about 80 psi (5.5 bars). Problème: La vanne ne s’ouvre pas électriquement. Primero, ponga en marcha la válvula manualmente abriendo la palanca/el tornillo de purga manual. (girando en sentido contrario a las agujas del reloj). Cierre la palanca/el tornillo de purga manual cuando se haya completado el test manual. 3. Hay piedras o residuos entre la . . . . Desconecte el agua. Retire la cubierta de la válvula arandela y el asiento de válvula y el ensamblaje de diafragma y limpie el interior de la válvula. 3. Il y a des débris dans l’orifice . . . . . Coupez l’eau. Retirez le solénoïde. Introduisez un circulaire fil ou un grand trombone par l’orifice circulaire et, d’un mouvement de va et vient, enlevez tous les débris. Assurez-vous que le plongeur et le joint torique sont à leur place lors du remontage. 4. Le solénoïde est défectueux . . . . . . . Coupez l’eau. Dévissez le solénoïde et remplacez-le par celui d’une vanne en bon état. Si la vanne fonctionne, replacez le solénoïde. Assurez-vous que le plongeur et le joint torique sont à leur place lors du remontage. 5. Le plongeur du solénoïde est bloqué Coupez l’eau. Retirez le solénoïde et enlevez sable et débris. Assurez-vous que le plongeur et le joint torique sont à leur place lors du remontage. Problème: La vanne ne se ferme pas Vérifiez si... Solution 1. La vanne est correctement posée . . . Assurez-vous que les flèches indiquent le sens d’écoulement de l’eau. 2. Le plongeur du solénoïde est bloqué Coupez l’eau. Retirez le solénoïde et enlevez sable et débris. Assurez-vous que le plongeur et le joint torique sont à leur place lors du remontage. 3. Une pierre ou des débris sont pris . . Coupez l’eau. Retirez le couvercle de la vanne et la membrane, et nettoyez l’intérieur de la vanne. entre la rondelle et le siège de la vanne 4. La membrane s’est déchirée . . . . . . . Coupez l’eau. Retirez le couvercle et décelez toute déchirure de membrane. Remplacez la membrane en cas de déchirure. 4. Se ha roto el diafragma . . . . . . . . . . Cierre el agua. Retire la cubierta e inspeccione el diafragma en busca de desgarros. Retire el ensamblaje del diafragma si se encuentra rasgado. Problème: Fuites à l’extérieur de la vanne Solution Vérifiez si... Problema: Fugas en las válvulas externas Compruebe si... Solución 1. Les raccords en PCV qui entrent dans Posez une bonne quantité de ruban pour joints filetés sur les filets et serrez fermement. Ne serrez 1- la vanne sont correctement posés pas excessivement. 1. Los accesorios PVC que van a la . . . 1- válvula no están instalados correcta mente 2. La presión es demasiado alta . . . . . . Utilice una cinta adhesiva para sujetar firmemente las roscas. No las sujete demasiado fuerte. 2. La pression est excessive . . . . . . . . . Installez un régulateur de pression en amont de la vanne et réglez-le à environ. Instale un regulador de presión contracorriente de la válvula y establezca una presión de 80 psi (5.5 bars). 3. Fuites sous le solénoïde . . . . . . . . . . Coupez l’eau. Serrez le solénoïde. 3. Hay una perdida debajo del solenoide. . Cierre el agua. Apriete firmemente el solenoide.
  • Page 1 1
  • Page 2 2

ORBIT IRRIGATION 57471 El manual del propietario

Tipo
El manual del propietario