Little GIANT ES33D1-10 Introduction Manual

Tipo
Introduction Manual
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you long
and reliable service. Little Giant pumps are carefully tested, inspected,
and packaged to ensure safe delivery and operation. Please examine
your pump carefully to ensure that no damage occurred during ship-
ment. If damage has occurred, please contact the place of purchase.
They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant Submersible Sump and Sewage Pumps are recom-
mended for use in basins or lift stations and suitable for pump-
ing non-potable, residential drainage water, effluent, and other
non-explosive, non-corrosive liquids. The ES33 pumps have 3/8”
spherical solids handling capability. Other accessories such as
basins, check valves and covers are also available.
SAFETY GUIDELINES
WARNING: Risk of electric shock. This pump is supplied with
a grounding conductor and grounding type attachment plug.
To reduce the risk of electric shock, be certain that it is
connected to a properly grounded, grounding type receptacle.
Your pump is equipped with a 3-prong electrical plug. The
third prong is to ground the pump to prevent possible electrical
shock hazard. Do not remove the third prong from the plug.
A separate branch circuit is recommended. Do not use an
extension cord.
When a pump is in a basin, etc., do not touch motor, pipes or
water until unit is unplugged or shut off. If shut-off box is not
accessible, call the electric company to shut off service to the
house, or call your local fire department for instructions. Failure to
follow this warning can result in fatal electrical shock.
The flexible jacketed cord assembly mounted to the pump must
not be modified in any way, with the exception of shortening the
cord to fit into a control panel. Any splice between the pump and
the control panel must be made within a junction box and mount-
ed outside of the basin, and comply with the National Electrical
Code. Do not use the power cord for lifting the pump.
The pump motor is equipped with an automatic resetting thermal
protector and may restart unexpectedly. Protector tripping is an
indication of motor overloading as a result of excessively high or
low voltage, inadequate wiring, incorrect motor connections, or a
defective motor or pump.
1. Read all instructions and safety guidelines thoroughly. Failure
to follow the guidelines and instructions could result in serious
bodily injury and/or property damage.
2. DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS
SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. DO
NOT USE IN EXPLOSIVE ATMOSPHERES OR HAZARDOUS
LOCATIONS AS CLASSIFIED BY NEC, ANSI/NFPA70. FAILURE
TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
3. During normal operation the sump pump is immersed in
water. Also, during rain storms, water may be present in
the surrounding area of the pump. Caution must be used to
prevent bodily injury when working near the pump:
a. The plug must be removed from the receptacle prior to
touching, servicing or repairing the pump.
b. To minimize possible fatal electrical shock hazard, extreme
care should be used when changing fuses. Do not stand
in water while changing fuses or insert your finger into
the fuse socket.
4. Do not run the pump in a dry basin. If the pump is run in a dry
basin, the surface temperature of the pump will rise to a high
level. This high level could cause skin burns if the pump is
touched and will cause serious damage to your pump.
5. Do not oil the motor. The pump housing is sealed. A high
grade dielectric oil devoid of water has been put into the motor
housing at the factory. Use of other oil could cause serious
electric shock and/or permanent damage to the pump.
6. This pump’s motor housing is filled with a dielectric oil for
motor heat transfer and lifetime lubrication of the bear-
1
ES33D1-10, ES33D1-20
ES33M1-10, ES33M1-20
ES33V1-10, ES33V1-20
ES33W1-10, ES33W1-20
U.S. Patent 6,867,383
ES33W1
E
S33M1
ES3
3V1
ES
33D1
Figure 1
Franklin Electric Co., Inc.
P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-[email protected]
ings. This oil is non-toxic to aquatic life.
However, suffocation can occur if oil is
left on the water surface. If oil escapes the
motor housing it can be removed from the
surface quickly by placing newspapers
on the water surface to soak up the oil.
7. In any installations where property damage
and/or personal injury might result from an
inoperative or leaking pump due to power
outages, discharge line blockage, or any
other reason, a backup system(s) and/or
alarm should be used.
OPERATION
TESTING PUMP OPERATION
ES33 SERIES SUMP PUMPS:
1. All pumps except ES33M are equipped
with an automatic switch. Pump must be
plugged into switch for automatic opera-
tion.
2. When these pumps are installed in a basin
with a sealed cover, switch operation cannot
be observed. The sump cover usually will
have a spare hole that is plugged with a
rubber plug. This plug can be removed and
switch operation can be observed.
3. Plug power cord into a grounded receptacle
with voltage consistent with pump voltage
as indicated on pump nameplate.
4. Run water into basin until pump starts.
5. Be sure gate valve in discharge line is
open.
6. Allow pump to operate through several
on-off cycles.
MAINTENANCE
If pump does not operate properly, consult the troubleshooting
chart. If trouble cannot be located with these steps shown, consult
your pump dealer or take pump to a Little Giant authorized service
center.
CAUTION: When working on pump or switch, always unplug
pump power cord in addition to removing fuse or shutting off cir-
cuit breaker before working on pump.
CLEANING IMPELLER AND VOLUTE
1. Remove (8) screws that hold screen to volute, and volute to
motor housing.
2. Remove volute and clean impeller and volute passage. Do not
use strong solvents on impeller.
3. Be sure impeller turns freely after cleaning.
4. WARNING: DO NOT REMOVE IMPELLER. REMOVAL OF
IMPELLER REQUIRES SPECIAL TOOLS AND IS TO BE DONE
ONLY BY AN AUTHORIZED SERVICE CENTER.
DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY
IS VOID IF MOTOR HOUSING COVER, IMPELLER OR SEALS
HAVE BEEN REMOVED.
ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED
LITTLE GIANT SERVICE CENTER.
2
Pump power cord
Cordon d'alimentation de la pompe
Cable de potencia de la bomba
Discharge pipe no smaller than pump outlet
La canalisation de refoulement doit étre plus petite
que la sortie de pompe
Tubo de descarga que no sea más pequeño que la
salida de la bomba
Union
Raccord
Unión
2" or 3" vent pipe
Canalisation de ventilation de 2 ou 3 po
Tubo de ventilación 2" ó 3"
Power cord grommet
Oeillet du cordon d'alimentation
Anillo protector del cable de potencia
Basin cover
Couvercle du bassin
Tapa del recipiente
Wall
Mur
Power cord taped to pipe
Fil d'alimentation collé au tuyau avec un ruban
Cordón eléctrico sujeto a la tubería con cinta adhesiva
3/16" dia. bleed hole in discharge pipe
Trou de dégagement diam. 3/16 po sur le tuyau d'écoulement
Agujero de purgado de 3/16" de diámetro en la tubería de descarga
Place pump on hard level surface. Never place
directly on clay, earth or gravel surface.
La pompe doit être installée sur une surface dure. N'installez jamais la
pompe sur une surface argileuse, terreuse ou sableuse.
Posicione la bomba sobre una superficie dura y nivelada y nunca
posicione la bomba directamente sobre superficies de arcilla, tierra o grave.
3.5" tether length
Fil de l'interrupteur: 3.5 po
Prisionero de 3.5"
ES33D1: 10"–12" on level • 10 po à 12 po à
niveau • 10" a 12" en el nivel
ES33V1: 5"–6" on level • 5 po à 6 po à
niveau • 5" a 6" en el nivel
ES33W1: 10"–12" on level • 10 po à 12 po à
niveau • 10" a 12" en el nivel
ES33D1: 4"–6" off level • 4 po à 6 po hors
niveau • 4" a 6" fuera del nivel
ES33V1: 2" off level • 2 po hors niveau
• 2" fuera del nivel
ES33W1: 8"–10" off level • 8 po à 10 po
hors niveau • 8" a 10" fuera del nivel
TYPICAL INSTALLATION • INSTALLATION TYPE • INSTALACION TIPICA
Separate protected and grounded service outlet 4' from floor min.
Prise de courant de mise à la terre à protection séparée à une distance minimale de 4 pi du sol
Tomacorrientes de servicio conectado a tierra y protegido separado por lo menos a 4 pies del suelo
Gate valve
Clapet de la vanne
Válvula de la compuerta
Check valve
Clapet de retenue
Verifique válvula
Gas tight basin 18" dia. x 22" deep min.
Bassin anatibactérien d'un diamètre minimal compris
entre 18 po et 22 po
Recipiente hermético al gas de 18" diámetro y de
un mínimo de 22" de profundidad
MODEL
NO. LISTING HP VOLTS
SOLIDS
SIZE (dia.
in.)
AMPS/
WATTS
GPM @ HEAD
SHUT
OFF P.S.I.
PWR.
CORD (ft.)
WT.
(Lbs.)
5’ 10’ 15’ 20’
ES33 CSA/cCSAus 1/3 115 3/8” 5/475 57 40 28 0 20 8.6 10* 30
*20’ cord optional
Figure 2
SPECIFICATIONS
Discharge Size: 1-1/2” NPT vertical
Intake Size: 3/8” screened opening
Horsepower: 1/3 HP
Pump Housing: Cast iron
Volute: Plastic
Screen: Plastic
Impeller: Plastic vortex design
Motor: Single phase permanent split capacitor with
automatic reset thermal overload protection.
Hardware: 300 Series stainless steel
Bearings: Ball bottom, sleeve top
Pump Shaft Seal: Mechanical, spring loaded, stationary carbon
with Nitrile boot and rotating ceramic seat.
Power Cord: 16 AWG 3-conductor, copper, stranded, 10’ or
12’ length
Cooling: The motor housing contains a cooling oil to
provide cooling for the motor and to lubricate
bearings and seals. These pumps are capable of
operating with the motor housing partially exposed
for extended periods of time, providing sufficient
motor cooling and bearing lubrication. However,
for the best cooling and longest motor life, the
liquid level being pumped should normally be
above the top of the cast iron motor housing.
INSTALLATION
Pump must be installed in a suitable gas tight basin which is at
least 18” in diameter and 24” deep.
The ES33 Series pumps feature a 1/3 HP, 1-1/2” female NPT
discharge.
Pump can be installed with ABS, PVC, polyethylene or galvanized steel
pipe. Proper adapters are required to connect plastic pipe to pump.
Pump must be placed on a hard level surface. Never place pump
directly on clay, earth or gravel surfaces.
A check valve must be used in the discharge line to prevent back
flow of liquid into the basin. The check valve should be a free flow
valve that will easily pass solids.
CAUTION: For best performance of check valves, when handling
solids install in a horizontal position or at an angle of no more than
45°. Do not install check valve in a vertical position as solids may
settle in valve and prevent opening on start-up.
When a check valve is used, drill a relief hole (1/8” or 3/16” diameter)
in the discharge pipe. This hole should be located below the floor
line between the pump discharge and the check valve. Unless
such a relief hole is provided, the pump could “air lock” and will
not pump water even though it will run.
WIRING
Check local electrical and building codes before installation. The
installation must be in accordance with their regulations as well as
the most recent National Electrical Code (NEC).
To conform to the National Electrical Code all pumps must be wired
with 14 AWG or larger wire. For runs to 250 feet 14 AWG wire is sufficient.
For longer runs consult a qualified electrician or the factory.
Pump should be connected or wired to its own circuit with no other
outlets or equipment in the circuit line.Fuses and circuit breaker should
be of ample capacity in the electrical circuit (see chart below).
MINIMUM
FUSE OR CIRCUIT
H.P. VOLTAGE BREAKER AMPS
1/3 115 15
INTRODUCTION
FR
Cette feuille d’instructions vous fournit les informations néces-
saires pour entretenir et faire fonctionner votre produit Little Giant.
Conserver ces directives afin de pouvoir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement
fabriqué avec des matériaux de la plus haute qualité et a été conçu
pour durer longtemps et offrir un service fiable. Les produits Little
Giant sont soigneusement testés, inspectés et emballés afin d’en
assurer la sécurité de fonctionnement et une livraison en bonne
condition. Vérifier attentivement le produit afin de vous assurer qu’il
n’a pas été endommagé pendant le transport. S’il est endommagé,
veuillez contacter l’entreprise qui vous l’a vendu. Si une réparation ou
un remplacement est requis, elle vous prêtera assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE
PROCÉDER À L’INSTALLATION, À L’UTILISATION OU À
L’ENTRETIEN DU PRODUIT LITTLE GIANT. SE FAMILIARISER
AVEC LES APPLICATIONS, LES LIMITES ET LES RISQUES
POTENTIELS DU PRODUIT. ASSURER SA PROPRE
PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES
LES RÈGLES DE SÉCURITÉ. LE NON-RESPECT DE CES
DIRECTIVES PEUT ENTRAÎNER DES BLESSURES ET/OU DES
DOMMAGES MATÉRIELS!
DESCRIPTION
Les pompes submersibles à puisard de Little Giant sont recomman-
dées pour les bassins et les stations de pompage et sont conçues
pour eau de drainage non-potable, résidentielle de pompage, effluent
et d’autres liquides non explosifs et non corrosifs. Les pompes ES33
peuvent pomper des matières solides sphériques de 9 mm (3/8 po).
D’autres accessoires comme des bassins, des clapets anti-retour et
des couvercles sont également disponibles.
DIRECTIVES DE SECURITE
AVERTISSEMENT : Danger d’électrocution. Cette pompe est
équipée d’un conducteur de terre et d’une prise de terre mâle.
Pour éviter tout danger d’électrocution, s’assurer que la prise
est connectée à une prise de courant bipolaire plus terre.
Votre pompe est dotée d’une fiche à trois branches. La troisième
branche a pour fonction de mettre la pompe à la terre afin de
prévenir tout choc électrique. Ne pas couper cette troisième
branche. Il est recommandé de brancher la pompe à un circuit
indépendant. Éviter d’utiliser une rallonge.
Lorsqu’une pompe est dans un réservoir, éviter de toucher au
moteur, aux tuyaux ou à l’eau si la pompe n’est pas débran-
chée ou hors tension. Si le panneau électrique n’est pas acces-
sible, communiquer avec votre compagnie d’électricité pour
qu’elle coupe l’alimentation de la maison, ou avec votre service
d’incendie pour connaître la marche à suivre dans ces circon-
stances. Le non-respect de cet avertissement pourrait résulter en
un choc électrique fatal.
Le fil d’alimentation flexible de la pompe, gainé de ne doit être
modifié d’aucune façon, sauf pour être raccourci afin qu’il entre
dans un panneau de commande. Toute épissure entre la pompe
et le panneau de commande doit être faite à l’intérieur d’une boîte
d’accouplement et installée hors du réservoir; elle doit aussi être
conforme au Code national de l’électricité. Ne pas soulever la
pompe à l’aide du fil d’alimentation.
Le moteur de la pompe est pourvu d’un dispositif de protection
thermique à démarrage automatique ; elle peut redémarrer à tout
moment. Le déclenchement du dispositif de protection indique
une surchauffe du moteur provoquée par un voltage excessif ou
insuffisant, un câblage non approprié, des erreurs de raccordement
du moteur, une défaillance du moteur ou une défaillance de
la pompe.
1. Bien lire les instructions du guide de sécurité. Le non-respect
des consignes de sécurité peut causer de graves blessures ou
des dommages à la propriété, ou les deux.
2. Ne pas utiliser pour pomper des liquides explosifs ou inflam-
mables (essence, huile, kérosène, etc.) Ne pas utiliser dans
des environnements explosifs ou des lieux considérés comme
dangereux (voir Code nat. de l’Élect., ANSI/NFPA70). Le
non-respect de cette mesure de sécurité peut causer des dom-
mages ou des blessures.
3. Durant le fonctionnement normal du système, la pompe à
puisard est immergée, donc invisible. De plus, pendant les
orages, il pourrait y avoir de l’eau autour de la pompe. C’est
pourquoi il faut faire attention si on travaille près de celle-ci.
a. Débrancher la pompe avant d’y toucher ou d’en faire l’entretien
ou la réparation.
b. Afin de réduire le risque d’électrocution, faire preuve d’une
grande prudence pendant le remplacement des fusibles.
Ne pas avoir les pieds dans l’eau pendant le remplacement
des fusibles et ne pas insérer le doigt dans les culots de
fusibles.
4. Ne pas faire fonctionner la pompe dans un réservoir à sec.
Si cela se produisait, la température de surface de la pompe
deviendrait assez élevée pour causer de graves brûlures et
endommager sérieusement la pompe.
3
5. Ne pas lubrifier le moteur. Le boîtier de la pompe est scellé. De
l’huile diélectrique de haute qualité sans eau a été mise dans
le boîtier en usine. L’utilisation d’un autre type d’huile pourrait
causer un choc électrique grave ou gravement endommager
la pompe, ou les deux.
6. Le boîtier du moteur de cette pompe est rempli d’une huile diélec-
trique, pour un transfert de chaleur optimal et une lubrification
durable des paliers. Cette huile n’est d’aucun danger pour la vie
aquatique. Il y a toutefois risque de suffocation si l’huile reste à la
surface de l’eau. S’il devait y avoir fuite, retirer l’huile de la surface
en plaçant du papier journal sur l’eau afin d’absorber l’huile.
7. L’utilisation d’un ou de plusieurs systèmes auxiliaires et/ou d’un
système d’alarme est recommandée pour toute installation
potentiellement dangereuse (fuite ou défectuosité causées par
une coupure de courant, un blocage du circuit de refoulement
ou pour toute autre raison) pour les personnes ou la propriëtë.
FONCTIONNEMENT
VÉRIFICATION DU FONCTIONNEMENT DE LA POMPE
POMPES À PUISARD DE SÉRIE ES33 :
1. Toutes les pompes sauf ES33M sont équipées d’un inter-
rupteur automatique. La pompe doit être branchée dans le
commutateur pour l’opération automatique.
2. Lorsque ces pompes sont installées dans bassin avec un cou-
vercle scellé, le fonctionnement du commutateur ne peut être
observé. Le couvercle du puisard comporte généralement un
trou supplémentaire obstrué par un bouchon en caoutchouc.
Ce bouchon peut être enlevé pour observer le fonctionnement
du commutateur.
3. Brancher les fils d’alimentation de la pompe et de l’interrupteur
dans une prise mise à la terre en s’assurant que la tension de celle-
ci correspond à la tension indiquée sur la plaque signalétique.
4. Remplir le réservoir d’eau jusqu’à ce que la pompe se mette
en marche.
5. S’assurer que la vanne à obturateur du conduit de sortie est ouverte.
6. Laisser la pompe s’allumer et s’éteindre à plusieurs reprises.
ENTRETIEN
Si la pompe ne fonctionne pas convenablement, consultez le
tableau de relève des dérangements. Si vous pouvez identifier le
problème en suivant les étapes indiquées, consultez le fournis-
seur de votre pompe ou rapportez la pompe à un centre de ser-
vice autorisé Little Giant.
MISE EN GARDE : Avant tout entretien ou réparation effectué sur
la pompe ou l’interrupteur, toujours débrancher la pompe et retirer
le fusible (ou déclencher le disjoncteur).
NETTOYAGE DE LA TURBINE ET DE LA VOLUTE
1. Enlever les vis qui retiennent le grillage à la volute et la volute
au boîtier du moteur.
2. Retirer la volute et nettoyer la turbine ainsi que le passage de
la volute. Éviter d’utiliser de puissants solvants sur la turbine.
3. Veillez à ce que la turbine tourne librement une fois le
nettoyage terminé.
4. AVERTISSEMENT : LAISSEZ LA TURBINE EN PLACE. LE
RETRAIT DE LA TURBINE NÉCESSITE DES OUTILS SPÉCIAUX
ET NE PEUT ÊTRE EFFECTUÉ QU À UN CENTRE DE SERVICE
AUTORISÉ.
LAISSER LE COUVERCLE DU BOÎTIER DU MOTEUR EN
PLACE. LE RETRAIT DU COUVERCLE DU BOÎTIER DU MOTEUR,
DE LA TURBINE OU DES JOINTS ANNULE LA GARANTIE.
TOUTE RÉPARATION DU MOTEUR DOIT ÊTRE EFFECTUÉE
À UN CENTRE DE SERVICE AUTORISÉ LITTLE GIANT .
CARACTÉRISTIQUES TECHNIQUES
Taille D’écoulement : 1-1/2” po NPT Vertical
Taille D’aspiration : Ouverture grillagée de 3/8” po
Chevaux-vapeur : 1/3 Ch
Boîtier de la pompe : Fonte
Volute : Plástico
Grille : Plástico
Turbine : Conception avec vortex en plastique
Moteur : Condensateur auxiliaire permanent mono-
phasé avec protecteur thermique à réen-
clenchement automatique
Attaches. : Acier inoxydable, série 300
Roulements : Bille à la base, manchon sur le dessus
Joint étanche de
l’arbre du moteur : Contacteur mécanique à ressort, carbone
fixe avec enveloppe en nitrile et siège rota-
tif en céramique
Cordon
d’alimentation : 16 AWG 3 conducteurs, cuivre, à torons, 3
ou 3,65 m (10 ou 12 pieds) de long
Refroidissement : Le boîtier du moteur renferme une huile de
refroidissement pour le moteur, qui lubri-
fiera aussi les paliers et les joints d’étanchéité.
Même si le boîtier du moteur était partiellement
exposé, ces pompes pourraient fonctionner
pour de longues périodes de temps, à con-
dition que le refroidissement et la lubrification
soient adéquats. Toutefois, il est recommandé
que le niveau du liquide à pomper soit au-
dessus du boîtier de fonte afin d’assurer
le meilleur refroidissement possible et de
prolonger la durée de vie du moteur.
INSTALLATION
La pompe doit être installée dans un bassin approprié, étanche
au gaz et mesurant au moins 46 cm (18 po) de diamètre et 61 cm (24
po) de profondeur.
Les pompes de série ES33 possèdent une évacuation femelle de
1½ po de type NPT, de 1/3 HP.
La pompe peut être installée avec des tuyaux d’acier galvanisé,
de polyéthylène, d’ABS ou de PVC. Des adaptateurs sont requis
pour raccorder le tuyau de plastique à la pompe.
La pompe doit être placée sur une surface plate et dure. Ne jamais
placer la pompe directement sur de l’argile, de la terre ou des
surfaces en concassé.
Un clapet de retenue doit être placé dans la conduite de sortie afin
de prévenir tout reflux de liquide à l’intérieur du réservoir. Le clapet
devrait être à flot libre et pouvoir laisser passer des matières solides.
MISE EN GARDE : Afin d’obtenir une performance maximale
des clapets de retenue pendant le pompage de matières solides,
installer les clapets à l’horizontale ou à un angle ne dépassant
pas 45°. Éviter de les installer à la verticale, car des matières sol-
ides pourraient rester coincées dans le clapet et empêcher son
ouverture lors de la mise en marche de la pompe.
Dans ce cas, percer dans le tuyau d’écoulement un trou de
dégagement d’un diamètre de 1/8 po à 3/16 po, en-dessous du
sol entre l’écoulement de la pompe et la soupape d’arrêt pour
éviter qu “un bouchon d’air” se produise qui empêcherait l’appareil
de pomper même s’il fonctionnait normalement.
CÂBLAGE
Vérifier les codes locaux de l’électricité et du bâtiment avant
l’installation. Celle-ci devrait être conforme avec ces règlements
ainsi qu’avec le plus récent Code national de l’Électricité.
4
Afin de respecter les exigences du Code national de l’Électricité,
toute les pompes doivent être branchées avec du fil #14 AWG ou
plus gros. Pour des longueurs de fils inférieures à 250 pi, un fil
#14 AWG convient. Consulter un électricien ou l’usine pour des
longueurs plus élevées.
La pompe devrait être branchée à un circuit indépendant. Aucun
autre appareil ne devrait être branché à ce circuit, et les fusibles
et disjoncteurs devraient être de capacité adéquate. Consulter le
tableau ci-dessous.
AMPÉRAGE MINIMUM DU FUSIBLE
Ch VOLTAGE OU DU DISJONCTEUR
1/3 115 15
INTRODUCCIÓN
ES
Esta hoja de instrucciones le proporciona la información requeri-
da para tener y operar de forma segura su producto Little Giant.
Guarde las instrucciones para referencia futura.
El producto Little Giant que ha adquirido se fabrica utilizando mano
de obra y materiales de la más alta calidad y ha sido diseñado para
prestarle un servicio duradero y confiable. Los productos Little Giant
son cuidadosamente probados, inspeccionados y empacados
para garantizarle una entrega y operación seguras. Examine su
unidad cuidadosamente para asegurarse de que no haya ocurrido
ningún daño durante el transporte. Si se ha presentado algún daño,
comuníquese con el lugar de compra. Deberán darle asistencia para
obtener la reparación o reemplazo, si se requiere.
LEA ESTAS INSTRUCCIONES CUIDADOSAMENTE ANTES
DE INTENTAR INSTALAR, HACER FUNCIONAR O PRESTAR
SERVICIO TÉCNICO A SU PRODUCTO LITTLE GIANT. CONOZCA
CUÁLES SON LAS APLICACIONES, LIMITACIONES Y PELIGROS
POTENCIALES DE LA UNIDAD. PROTEJA A TERCEROS Y
PROTÉJASE A USTED MISMO SIGUIENDO TODA LA
INFORMACIÓN DE SEGURIDAD. ¡LA FALTA DE CUMPLIMIENTO
DE ESTAS INSTRUCCIONES PUEDE PRODUCIR LESIONES
PERSONALES Y/O DAÑOS A LA PROPIEDAD!
DESCRIPTION
Las bombas sumergibles Little Giant para sumideros y aguas
cloacales se recomiendan para bombear agua de drenaje no
potable, residencial, efluente, y otros líquidos que no sean explo-
sivos o corrosivos. Las bombas ES33 cuentan con la capacidad
de manejar desechos sólidos esféricos de 9,5 mm (3/8 pulg.).
También hay otros accesorios disponibles, como cubetas, válvu-
las de retención y tapas.
NORMAS DE SEGURIDAD
ADVERTENCIA: PELIGRO DE CHOQUE ELÉCTRICO. Esta bomba
está dotada de un cable de puesta tierra y un enchufe accesorio
de puesta a tierra. Para reducir el riesgo de choque eléctrico,
cerciórese de que se encuentre conectada a un receptáculo del
tipo de puesta a tierra, debidamente puesto a tierra.
Su bomba está dotada de un enchufe eléctrico de tres dientes.
El tercer diente es para ponerla a tierra, con el fin de evitar el
riesgo de posibles choques eléctricos. No quite el tercer diente
del enchufe. Se recomienda un circuito de ramal independiente.
No utilice un cable de extensión.
Cuando la bomba se encuentre en un dique seco, etc., no toque el
motor, los tubos ni el agua, mientras no se encuentre desconectada
o apagada. Si hay agua o humedad en sus instalaciones, no toque
el área húmeda mientras no se haya cortado toda la electricidad. Si
la caja de interruptores no está accesible, llame a la compañía de
electricidad para que interrumpa el servicio a la casa, o pida instruc-
ciones al departamento local de bomberos. El hacer caso omiso de
esta advertencia, puede producir un choque eléctrico mortal.
El conjunto de cables flexibles con manguito de cloruro polivinílico
montado en la bomba, no debe modificarse de ninguna manera,
salvo para acortar el cable, con el fin de ajustarlo a un tablero de
mandos. Cualquier empalme entre la bomba y el tablero de mandos
debe efectuarse dentro de una caja de conexiones y montarse
fuera del dique seco. Además, debe ajustarse al Código Eléctrico
Nacional. No utilice el cable eléctrico para levantar la bomba.
El motor de la bomba está equipado con un protector térmico de
reposición automática y puede reposicionarse inesperadamente.
El accionamiento del protector es una indicación de sobrecarga
del motor debida a un voltaje demasiado alto o bajo, un cableado
inadecuado, conexiones de motor incorrectas o un motor o
bomba defectuosos.
1. Lea todo el instructivo, el no seguir estas recomendaciones
puede causar serios daños a la persona y al equipo.
2. NO USE LA UNIDAD PARA BOMBEAR LIQUIDOS
INFLAMABLES NI EXPLOSIVOS TALES COMO GASOLINA,
FUELOIL, QUEROSENO, ETC. NO SE USE EN AMBIENTES
EXPLOSIVOS O LUGARES EPLIGROSOS, SEGUN LA
CLASIFICACION DEL CODIGO ELECTRICO NACIONAL
(NEC) Y LA NORMA NFPA70 DEL INSTITUTO NACIONAL
NORTEAMERICANO DE NORMAS. EL HACER CASO OMISO
DE ESTA ADVERTENCIA, PUEDE TRAER COMO RESULTADO
LESIONES CORPORALES, DAÑOS MATERIALES O AMBOS.
3. Durante el funcionamiento normal la bomba de sumidero está
inmersa en agua. Además, durante las tormentas, puede haber
agua en el área circundante de la bomba. Se debe observar
precaución para prevenir lesiones personales al trabajar cerca
de la bomba.
a. Debe sacarse el enchufe de la toma de corriente, antes de
tocar, limpiar o reparar la bomba.
b. Para disminuir el riesgo de choques eléctricos posible-
mente fatales, tenga sumo cuidado al cambiar los fusibles.
No pise agua mientras cambia los fusibles ni introduzca el
dedo en el receptáculo del fusible.
4. No haga funcionar la bomba en un depósito seco. Si la
bomba es operada en un depósito seco, la temperatura de
la superficie de la bomba se elevará a un alto nivel. Este alto
nivel podría causar quemaduras de la piel si se toca la bomba
y puede causar daños graves a la bomba.
5. No engrase el motor. La caja de la bomba está sellada. Desde
la fábrica se ha colocado un aceite dieléctrico de alto grado
y repelente al agua dentro de la carcasa del motor. El uso de
otro tipo de aceite podría causar daños eléctricos graves y/o
daños permanentes a la bomba.
6. El alojamiento del motor de esta bomba está lleno con un aceite
dieléctrico para la transferencia de calor y la lubricación de por
vida de los cojinetes. Este aceite no es tóxico para la vida acuáti-
ca. Sin embargo, puede ocurrir la muerte de ésta, si el aceite
queda sobre la superficie. Para quitar rápidamente el aceite que
pueda haberse escapado del alojamiento del motor, coloque
periódicos sobre la superficie del agua para absorber el aceite.
7. EN CUALQUIER INSTALACION DONDE PUEDAN OCURRIR
DAÑOS MATERIALES Y/O LESIONES PERSONALES QUE
RESULTEN DEL FUNCIONAMIENTO INADECUADO O DE FUGAS
EN LA BOMBA A CAUSA DE FALLOS EN LA ALIMENTACION
ELECTRICA, BLOQUEO DE LA LINEA DE LA DESCARGA, O
CUALQUIER OTRA RAZON, SE DEBERA USAR UNO O
VARIOS SISTEMAS DE RESPALDO Y/O ALARMAS.
5
FUNCIONAMIENTO
PROBAR EL FUNCIONAMIENTO DE LA BOMBA
BOMBAS PARA SUMIDERO SERIE ES33:
1. Todas las bombas excepto ES33M son equipadas con un
interruptor automático. La bomba debe ser enchufada el
interruptor para la operación automática.
2. Al instalar estas bombas en una cubeta con la tapa sellada, no
se puede observar el funcionamiento del interruptor. La tapa
de la bomba generalmente cuenta con un orificio cubierto con
un tapón de caucho. Este tapón se puede retirar para observar
el funcionamiento del interruptor.
3. Conecte el cable eléctrico del interruptor de control remoto
accionado por un flotador a un receptáculo puesto a tierra,
con un voltaje similar al de la bomba, como se indica en la
placa del fabricante de la bomba. Conecte el cable eléctrico
de la bomba en el enchufe del interruptor de control remoto,
accionado por el flotador.
4. Haga correr agua en la bomba, hasta que la bomba
arranque.
5. Cerciórese de que la válvula de paso directo del tubero de
descarga se encuentre abierta.
6. Permite que la bomba funcione durante varios ciclos de
apagado y encendido.
MANTENIMIENTO
Si la bomba no funciona apropiadamente, consulte el plano de
investigación de averías. Si no puede encontrar el problema
siguiendo estos pasos, consulte al distribuidor de la bomba o
lleve la bomba a un centro de servicio autorizado de Little Giant.
PRECAUCION: Cuando trabaje en la bomba o en el interruptor,
desconecte siempre el cable eléctrico, además de quitar el fusible o
apagar el interruptor automítico, antes de trabajar en la bomba.
LIMPIEZA DEL ROTOR Y EL DIFUSOR
1. Retire los tornillos que sujetan la malla al espiral y el espiral al
alojamiento del motor.
2. Limpie el rotor y el conducto del difusor. No utilice detergen-
tes fuertes en el impulsor.
3. Asegúrese de que el impulsor gire libremente antes de limpiarlo.
4. ADVERTENCIA: NO QUITE EL IMPULSOR. PARA QUITAR EL
IMPULSOR SE REQUIEREN HERRAMIENTAS ESPECIALES Y
ESTO DEBE HACERSE SOLO EN UN CENTRO DE SERVICIO
AUTORIZADO.
NO QUITE LA CUBIERTA DE LA CAJA DEL MOTOR. LA
GARANTIA ES NULA SI SE QUITA LA CUBIERTA DE LA CAJA
DEL MOTOR, EL IMPULSOR O LOS OBTURADORES.
CUALQUIER REPARACION DEL MOTOR DEBE HACERSE EN
UN CENTRO DE SERVICIO AUTORIZADO DE LITTLE GIANT.
ESPECIFICACIONES
Tamaño
de la Descarga: 1-1/2” NPT Vertical
Tamaño de la Toma: abertura de 3/8” pulgadas de diámetro
Caballos de fuerza: 1/3 KP
Bastidor
de la bomba: Hierro colado
Voluta: Plástico
Difusor: Plástico
Propulsor: Diseño de vórtex de plástico
Motores: Capacitor con división permanente monofásico
con protección contra sobrecarga térmica
de reestablecimiento automático
Piezas Metalicas: Serie 300, de acero inoxidable
Cojinetes: Inferior bola, superior manguito
Sello del eje
de la bomba: Carbón estacionario, mecánico y cargado
con resorte con protector de nitrilo y base
giratoria de cerámica
Cable de potencia: Calibre 16 de 3 hilos de cobre, trenzado de
3 ó 3,6 metros (10 ó 12 pies) de largo
Enfriamiento: El estator contiene un aceite refrigerante
para enfriar el motor y lubricar los cojine-
tes y obturadores. Estas bombas pueden
funcionar largo tiempo con el estator par-
cialmente expuesto, siempre y cuando el
refrigerante del motor y la lubricación de
los cojinetes sea sulficiente. No obstante,
para un enfriamiento óptimo y una vida
máxima del motor, el nivel del líquido que
se bombee, normalmente debe encontrarse
por encima del estator de hierro colado.
INSTALACION
La bomba se debe instalar en una cubeta apropiada, hermética al
gas, que tenga por lo menos 45,7 cm (18 pulg.) de diámetro y 61
cm (24 pulg.) de profundidad.
Las bombas serie ES33 incluyen una descarga NPT hembra de 1 ½
pulg. (38,1 mm) de 1/3 HP.
La bomba puede instalarse con tubos ABS, de cloruro polivinílico
(PVC) o de acero galvanizado. Para conectar el tubo plástico a la
bomba, se requieren adaptadores apropiados.
La bomba debe colocarse en una superficie dura y nivelada. No
la coloque nunca directamente sobre superficies de arcilla, tierra
o grava.
Debe utilizarse una válvula de retención en el tubo de descarga,
para evitar el reflujo en el dique seco. La válvula de retención
debe ser una válvula sin estrangulación, que permita pasar
fácilmente cuerpos sólidos.
Cuando se utilice una válvula de retención, perfórese un agujero
de descompresión (de un diámetro de 1/8 ó 3/16 de pulgada) en
el tubo de descarga. Este agujero deberá encontrarse debajo de
la línea de la superficie del suelo, entre la descarga de la bomba
y la válvula de retención. A menos que se proporcione tal agujero
de descompresión, la bomba podría llenarse de burbujas de aire
y no bombeará el agua, aunque sí funcionará.
CABLES
Estudie las normas locales sobre electricidad y construcción,
antes de instalar los cables. La instalación debe ajustarse a sus
regulaciones así como a las del Código Eléctrico Nacional (NEC)
más reciente.
Para ajustarse a las disposiciones del Código Eléctrico Nacional,
todas las bombas deben tener cables 14 AWG o mayores. Para
recorridos 250 pies, basta el cable de 14 AWG. Para recorridos
mayores, consulte a un electricista competente o a la fábrica.
La bomba debe enchufarse o conectarse en su propio circuito,
sin otras tomas o equipos en la línea del circuito. Los fusibles e
interruptores automíticos del circuito eléctrico deben ser de gran
capacidad. Remítase al siguiente cuadro:
AMPERIOS MÍNIMOS DEL
KP VOLTIOS FUSIBLE O CORTACIRCUITO
1/3 115 15
6
7
Figure 3
REPLACEMENT PARTS • PIÈCES DE RECHANGE • PIEZAS DE REEMPLAZO
ITEM
ARTICLE
ELEMENTO
DESCRIPTION • DESCRIPTION • DESCRIPCIÓN
PART No.
No DE PIÈCE
Nº DE PIEZA
1
Pump Lifting Ring, 2.72” Dia. Plated Steel
Anneau de levage de la pompe, en acier plaqué de 6,9 cm (2,72 po) de dia.
Anillo para levantar la bomba, diámetro de 69 mm (2,72 pulg.) Acero enchapado
106437
2
Washer, #10 Lock, 410SS
Rondelle de blocage, no 10, 410 inox.
Arandela de seguridad Nº 10, 410SS
921023
3
Screw, #10 x 3/8”, Pan Head, Phillips Drive
Vis, no 10 x 3/8 po, tête cylindrique bombée, cruciforme
Tornillo Phillips de cabeza Pan Nº 10 x 9,53 mm (3/8 de pulg.)
902525
4A
Bracket, Mounting, SS, “ES33D” Series
Support de montage, inox, de série « ES33D »
Soporte de montaje de acero inoxidable, serie “ES33D”
170263
4B
Bracket, Mounting, SS, “ES33V” Series
Support de montage, inox, de série « ES33V »
Soporte de montaje de acero inoxidable, serie “ES33V”
170265
4C
Clamp, Loop, Strain Relief, Nylon
Collier de cadre, de réduction de tension, nylon
Abrazadera de bucle de nilón para alivio de presión
927027
5A
Piggyback Switch, “ES33D”, 6” Vertical Diaphragm, 10ft, 115VAC
Interrupteur avec fiche jumelle, « ES33D », diaphragme vertical de 15,2 cm (6 po), 3 m (10 pi), 115 V c.a.
Interruptor en cascada, “ES33D”, diafragma vertical de 152,4 mm (6 pulg.), 3 metros (10 pies) 115 VCA
106002
5B
Piggyback Switch, “ES33V” 3” Vertical Mechanical, 10ft, 115VAC
Interrupteur avec fiche jumelle, « ES33V », diaphragme mécanique de 7,6 cm (3 po), 3 m (10 pi), 115 V c.a.
Interruptor en cascada, “ES33V”, mecánico vertical de 76,2 mm (3 pulg.), 3 metros (10 pies) 115 VCA
950010
5C
Piggyback Switch, “ES33W” Wide Angle Float, 10ft, 115VAC
Interrupteur avec fiche jumelle, à flotteur grand-angle « ES33W », 3 m (10 pi), 115 V c.a.
Interruptor en cascada, “ES33W”, flotador de ángulo amplio, 3 metros (10 pies) 115 VCA
950011
5D
Piggyback Switch, “ES33D” 6” Vertical Diaphragm, 20ft, 115VAC
Interrupteur avec fiche jumelle, « ES33D », diaphragme vertical de 15,2 cm (6 po), 6 m (20 pi), 115 V c.a.
Interruptor en cascada, “ES33D”, diafragma vertical de 152,4 mm (6 pulg.), 6 metros (20 pies) 115 VCA
106001
5E
Piggyback Switch, “ES33V” 3” Vertical Mechanical, 20ft, 115VAC
Interrupteur avec fiche jumelle, « ES33V », vertical, mécanique de 7,6 cm (3 po), 6 m (20 pi), 115 V c.a.
Interruptor en cascada, “ES33V”, mecánico vertical de 76,2 mm (3 pulg.), 6 metros (20 pies) 115 VCA
950012
5F
Piggyback Switch, “ES33W” Wide Angle Float, 20ft, 115VAC
Interrupteur avec fiche jumelle, à flotteur grand-angle « ES33W », 6 m (20 pi), 115 V c.a.
Interruptor en cascada, “ES33W”, flotador de ángulo amplio, 6 metros (20 pies) 115 VCA
950013
6
Seal Ring, Nitrile, Formed, ES33 Volute
Bague d’étanchéité, nitrile, formée, volute ES33
Anillo de sello de nitrilo formado, espiral ES33
928070
7
Volute, ES33, Black
Volute, ES33, noire
Espiral ES33 negro
106438
8
Base, Screen, ES33, Black
Base, grillage, ES33, noire
Base de rejilla ES33 negra
106434
9
Screw, 10-32 x 2.38”, SS, Phillips Pan Head
Vis, no 10-32 x 2,38 po, inox, cruciforme, tête cylindrique bombée
Tonillo Phillips de cabeza Pan Nº 10-32 x 60,5 mm (2,38 pulg.) de acero inoxidable
902524
8
TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS
• INFORMACION DE INVESTIGACION DE AVERIAS
PROBLEM • FONCTIONNEMENT
DÉFECTEUX • PROBLEMA
PROBABLE CAUSES • CAUSES PROBABLES
• CAUSAS PROBABLES
CORRECTIVE ACTION • SOLUTIONS
• SOLUCION
Pump does not turn on. • La pompe
ne peut être mise sous tension. • La
bomba no se activa.
Pump not plugged in. • La pompe n’est pas branchée. • La bomba
no está enchufada.
Plug in pump. • Branchez le puisard. • Enchufar la bomba.
Circuit breaker shutoff or fuse removed. • Disjoncteur coupé ou
fusible enlevé. • Desactivación del disyuntor o se ha retirado el
fusible.
Turn on circuit breaker or replace fuse. • Mettez le disjoncteur sous
tension ou remplacez le fusible. • Active el disyuntor o reemplace
el fusible.
Accumulation of trash on switch. • Accumulation de débris sur
le interrupteur. • Acumulación de desperdicios en el interruptor.
Clean switch. • Nettoyez le interrupteur. • Limpie el interruptor.
Switch obstruction. • Interrupteur bloqué. • Obstrucción del
interruptor.
Check switch path and provide clearance. • Vérifiez la voie de
passage du interrupteur et dégagez-la au besoin. • Verifique el
interruptor y proporcione espacio limpio.
Defective motor. • Moteur défectueux. • Motor defectuoso.
Have pump serviced by authorized service center. • Faites réparer
la pompe à un centre de service autorisé. • Lleve la bomba a un
centro de servicio autorizado.
Pump will not shut off. • Le moteur de
la pompe ne s’arrête pas. • La bomba
no se apaga.
Switch obstruction. • Interrupteur bloqué. • Obstrucción del
interruptor.
Check switch path and provide clearance. • Vérifiez la voie de
passage du interrupteur et dégagez-la au besoin. • Verifique el
interruptor y proporcione espacio limpio.
Pump is air locked. • Poche d’air dans la pompe. • Burbujas de
aire en la bomba.
Shut power off for approximately 1 minute, then restart. Repeat
several times to clear air from pump. • Couper le courant pendant
1 minute environ puis recommencer. Répéter cette opération plu-
sieurs fois pour évacuer l’air de la pompe. • Desconecte la elec-
tricidad durante un minuto, aproximadamente. Luego, vuélvala a
conectar. Repita varias veces, para purgar el aire de la bomba.
Liquid inflow matches pump capacity. • Afflux de liquide corre-
spondant au volume de la pompe. • El caudal que entra es igual
a la capacidad de la bomba.
Larger pump required. • Une pompe plus puissante est nécessaire.
• Se requiere una bomba mayor.
Pump runs but does not discharge
liquid. • La pompe fonctionne mais il
n’y a pas d’écoulement de liquide. •
La bomba funciona, pero no descarga
líquido.
Check valve installed backwards. • Montage à l’envers de la
soupape d’arrêt • Válvula de retención montada al revés
Check flow indicating arrow on check valve body to insure it is
installed properly. • Vérifier la fléche indiquant l’écoulement pour
s’assurer que la soupape d’arrêt est bien montée. • Inspeccione la
flecha indicadora del flujo en el cuerpo de la válvula de retención,
para cerciorase de que se encuentre instalada correctamente.
Check valve stuck or plugged. • Soupape d’arrêt bloquée ou
obstruée. • Válvula de retención atorada u ocluída.
Remove check valve and inspect for proper operation. • Démonter
et vérifier la soupape d’arrêt pour un bon fonctionnement. • Quite
la válvula de retención, y verifique que funcione debidamente.
Lift too high for pump. • Aspiration trop puissante pour la
pompe. • Altura de impulsión excesiva para la bomba.
Check rating table. • Vérifier le tableau d’évaluation. • Estudie la
tabla de capacidad.
Inlet to impeller plugged. • Arrivée de la roue à aubes obstruée.
• Toma de la rueda móvil conectada.
Pull pump and clean. • Tirer la pompe pour la nettoyer. • Saque la
bomba y límpiela.
Pump is air locked. • Présence d’une poche d’air dans la pompe.
• La bomba está llena de burbujas de aire.
(See corrective action above.) • (Voir ci-dessus la solution.)
• (Remítase a la solución anterior.)
Pump does not deliver rated capacity.
• La pompe ne pompe pas le volume
normal. • La bomba no impele a su
capacidad normal.
Lift too high for pump. • Aspiration trop puissante pour la pompe.
• Altura de impulsión excesiva para la bomba.
Check rated pump performance. • Vérifier les caractéristiques
techniques de la pompe. • Verifique el rendimiento normal de la bomba.
Low voltage, speed too slow. • Voltage et vitesse pas assez
puissants. • Voltaje demasiado bajo, velocidad demasiado baja.
Check for proper supply voltage to make certain it corresponds
to nameplate voltage. • S’assurer que le voltage correspond bien
à celui mentionné sur la plaque. • Verifique que el suministro de
electricidad sea adecuado, para cerciorarse de que corresponde
al voltaje indicado en la placa del fabricante.
Impeller or discharge pipe is clogged. • Obstruction de la roue
à aubes ou du tuyau d’écoulement. • La rueda móvil en el tubo
de descarga está ocluída.
Pull pump and clean. Check pipe for scale or corrosion. • Tirer la
pompe pour la nettoyer. Vérifier la présence de dépôts ou de cor-
rosion dans les tuyaux. • Saque la bomba y límpiela. Inspeccione
el tubo, en busca de capas de óxido o corrosión.
Pump cycles continually. • La pompe
recommence son cycle sans s’arrêter.
• La bomba se enciende y apaga con-
tinuamente
No check valve in long discharge pipe allowing liquid to drain
back into sump. • Absence de soupape d’arrêt dans le grand
tuyau d’écoulement ainsi permettant l’écoulement du liquide
dans le puisard de réception. • Falta la válvula de retención en
el tubo de descarga largo, lo cual permite que el líquido refluya
a la sumidero.
Install a check valve in discharge line. • Installer une soupape
d’arrêt sur le tuyau d’écoulement. • Instale una válvula de retención
en la tubería de descarga.
Check valve leaking. • Fuite à la soupape d’arrêt. • Escape en
la válvula de retención.
Inspect check valve for correct operation. • Vérifier la soupape
d’arrêt pour obtenir un bon fonctionnement. • Verifique que la vál-
vula de retención funcione correctamente.
Basin too small for inflow. • Bassin de réception trop petit pour
l’afflux. • El fondo del sumidero es muy pequeño o está inundado.
Install larger basin. • Installer une bassin de réception plus grand.
• Instale un sumidero con un fondo mayor.
9
LIMITED WARRANTY
SUMP & EFFLUENT
Little Giant ES33 Series Submersible Sump/Effluent Pumps are
recommended for use in sumps, basins or lift stations and suit-
able for pumping basement drainage water, effluent, wastewater
and other non-explosive, non-corrosive, non-abrasive liquids
not above 140°F with up to 3/8” spherical solids handling ability.
(NOT TO BE USED FOR SEWAGE WATER EXCEPT TO PUMP
SEPTIC TANK EFFLUENT.)
Little Giant products are guaranteed to be in perfect condition
when they leave our factory. During the time periods and subject
to the conditions hereinafter set forth, LITTLE GIANT, subsidiary of
Franklin Electric Company, Inc., will repair or replace to the original
user or consumer any portion of your new LITTLE GIANT product
which proves defective due to materials or workmanship of LITTLE
GIANT. Contact your nearest Authorized Little Giant Service
Station for warranty service. At all times LITTLE GIANT shall have
and possess the sole right and option to determine whether to
repair or replace defective equipment, parts, or components.
Damage due to lightning or conditions beyond the control of
LITTLE GIANT is NOT COVERED BY THIS WARRANTY.
WARRANTY PERIOD
PUMPS: 12 months from date of installation or 18 months from
date of manufacture, whichever comes first.
LABOR, ETC. COSTS: LITTLE GIANT shall IN NO EVENT be
responsible or liable for the cost of field labor or other charges
incurred by any customer in removing and/or affixing any LITTLE
GIANT product, part or component thereof.
THIS WARRANTY WILL NOT APPLY:
1. to defects or malfunctions resulting from failure to properly
install, operate, or maintain the unit in accordance with printed
instructions provided.
2. to failures resulting from abuse, accident or negligence.
3. to normal maintenance services and the parts used in connec-
tion with such service.
4. to units which are not installed in accordance with applicable
local codes, ordinances and good trade practices.
5. if unit is used for purposes other than for what it was designed
and manufactured.
6. if pump exposed to but not limited to the following: sand, gravel,
cement, grease, plaster, mud, tar, hydrocarbons, or hydrocar-
bon derivatives (oil, gasoline, solvents, etc.) or other abrasive
or corrosive substances.
7. if pump has been used for continuous pumping of suitable
liquids above 140°F.
8. if cord cut off to a length less than three feet.
9. if pump has been dismantled by customer. (Authorized Little
Giant Service Stations only can dismantle pump for field ser-
vice.)
RETURN OR REPLACED COMPONENTS: Any item to be
replaced under the Warranty must be returned to LITTLE GIANT
at Oklahoma City, OK or such other place as LITTLE GIANT may
designate, freight prepaid.
PRODUCT IMPROVEMENTS: Little Giant reserves the right to
change or improve its products or any portions thereof without
being obligated to provide such a change or improvement for
units sold and/or shipped to such change or improvement.
DISCLAIMER: Any oral statements about the product made
by the seller, the manufacturer, the representatives or any other
parties, do not constitute warranties, shall not be relied upon
by the user, and are not part of the contract for sale. Seller’s and
manufacturer’s only obligation, and buyer’s only remedy, shall be
the replacement and/or repair by the manufacturer of the product
as described above. Neither seller nor the manufacturer shall be
liable for any injury, loss or damage, direct, incidental or conse-
quential (including, but not limited to, incidental or consequential
damages for lost profits, lost sales, injury to person or property,
or any other incidental or consequential loss), arising out of the
use or the inability to use the product, and the user agrees that no
other remedy shall be available to it. Before using, the user shall
determine the suitability of the product for his intended use, and
user assumes all risk of liability whatsoever in connection therewith.
The warranty and remedy described in this limited warranty is
an EXCLUSIVE warranty and remedy and is IN LIEU OF any
other warranty or remedy, expressed or implied, which other war-
ranties and remedies are hereby expressly EXCLUDED, including
but not limited to any implied warranty of MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. Some states do
not allow the exclusive or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to
you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
In the absence of other suitable proof of the installation date,
the effective date of this warranty will be based upon the date of
manufacture plus one year. Direct All Notices, etc. To: Service
Department, LITTLE GIANT, 301 N. MacArthur Blvd., Oklahoma
City, OK 73127-6616.
DETERMINATION OF UNIT DATE OF MANUFACTURE: (9-87)
month and year stamped on pump and/or serial number on pump
nameplate coded to indicate year of manufacture.
GARANTIE LIMITÉE
POMPE À PUISARD ET À EFFLUENT
Les pompes submersibles pour puisard et effluent de Little Giant
de série ES33 sont recommandées pour une utilisation dans des pui-
sards, des bassins ou des stations de relèvement et conçues pour
le pompage des eaux de drainage d’un sous-sol, des eaux usées,
des eaux résiduaires et d’autres liquides non explosifs, non cor-
rosifs et non abrasifs ne dépassant pas 60°C (140°F) et contenant
des matières solides sphériques d’un diamètre pouvant aller
jusqu’à 5 mm (3/8 po). (NE PAS UTILISER POUR POMPER DES
EAUX D’ÉGOUTS, À L’EXCEPTION DES EAUX RÉSIDUAIRES
DE FOSSES SEPTIQUES).
Little Giant garantit que votre produit est en parfait état au moment
de quitter l’usine. Pour la durée et selon les conditions mention-
nées dans les présentes, LITTLE GIANT, filiale de Franklin Electric
Company, Inc., réparera ou remplacera au profit de l’acheteur ou
de l’utilisateur initial toute partie du produit LITTLE GIANT qui, à
cause d’un défaut de matériau ou de fabrication, sera défectueuse.
Communiquer avec le détaillant LITTLE GIANT le plus près de
chez vous pour des réparations sous la garantie. La réparation ou
le remplacement de l’appareil, des pièces ou des composantes
se fera à la seule discrétion de LITTLE GIANT, et ce en tout
temps. Les dommages dûs à la foudre ou à des circonstances
hors du contrôle de LITTLE GIANT NE SONT PAS COUVERTS
PAR LA PRÉSENTE GARANTIE.
DURÉE DE LA GARANTIE
POMPES : 12 mois à partir de la date d’installation, ou 18 mois à
partir de la date de fabrication, selon le premier terme atteint.
FRAIS DE MAIN-D’ŒUVRE, ETC. : EN AUCUN CAS, LITTLE
GIANT ne peut être tenue responsable des frais de main-d’œuvre
sur place ou de tout autre frais contracté par le client lors de
l’enlèvement ou de l’installation (ou des deux) de tout produit ou
pièce dudit produit LITTLE GIANT.
10
LA PRÉSENTE GARANTIE NE S’APPLIQUE PAS :
1. aux défauts ou défectuosités résultant d’une installation, d’une
utilisation ou d’un entretien non-conforme aux instructions
incluses avec le produit;
2. aux défectuosités résultant d’une mauvaise utilisation, d’un
accident ou de négligence;
3. à l’entretien normal et aux pièces nécessaires à cet entretien;
4. aux appareils qui n’ont pas été installés conformément aux
codes et règlements locaux ainsi qu’aux règles de l’art;
5. à un appareil utilisé dans un but autre que celui dans lequel il
fut conçu et fabriqué;
6. à une pompe qui a été exposée, entre autres, aux matières sui-
vantes : sable, gravier, ciment, graisse, plâtre, boue, goudron,
hydrocarbones et leurs dérivés (huile, essence, solvants, etc.)
ou autres substances abrasives ou corrosives;
7. à une pompe utilisée pour pomper sans interruption des liq-
uides non dangereux à des températures dépassant 140°F;
8. le fil d’alimentation a été coupé à une longueur inférieure à
0,91 m (trois pieds);
9. à une pompe démontée par l’utilisateur. (Seul le détaillant est
habilité à démonter la pompe sur place.)
RETOUR DE PIÈCES À REMPLACER : Toute pièce qui doit être
remplacée conformément à la garantie doit être retournée port
payé à l’entreprise LITTLE GIANT à Oklahoma City, Oklahoma
U.S.A. ou à tout autre endroit désigné par LITTLE GIANT.
AMÉLIORATIONS DE PRODUITS : LITTLE GIANT se réserve le
droit de modifier ou d’améliorer ses produits ou toute partie de
ces derniers sans être tenue d’apporter ces modifications aux
appareils vendus ou expédiés auparavant.
DÉNÉGATION : Toute déclaration sur la pompe faite oralement
par le vendeur, le fabricant, le représentant ou par toute autre
partie ne constitue pas une garantie et, par conséquent, ne peut
ni servir à l’utilisateur ni faire partie du contrat de vente. L’unique
obligation du vendeur et du fabricant, et l’unique recours de
l’acheteur, est le remplacement ou la réparation de la pompe
selon les modalités décrites précédemment. Ni le vendeur ni le
fabricant ne peuvent être tenus responsables de toute blessure,
toute perte ou tout dommage , direct, indirect ou accessoire
(incluant, mais non exclusivement, les ventes ou profits perdus,
les atteintes aux personnes ou à la propriété ou toute autre perte
indirecte ou accessoire) résultant de l’utilisation ou de l’incapacité
d’utilisation de la pompe, et l’acheteur convient qu’il ne dispose
d’aucun autre recours. Avant d’utiliser la pompe, il incombe à
l’acheteur de déterminer si la pompe choisie convient à l’usage
anticipé. L’acheteur accepte tout risque relié au choix de la
pompe. La garantie et les recours énoncés dans les présentes
sont EXCLUSIFS et REMPLACENT toute autre garantie ou recours
explicite ou implicite. Tout autre recours ou garantie est donc
expressément EXCLU.
Cela comprend, mais non exclusivement, toute garantie implic-
ite d’APTITUDE À LA COMMERCIALISATION OU D’APTITUDE
PARTICULIÈRE. Certaines juridictions ne permettent pas
l’exclusion ou la limitation pour des dommages indirects ou
accessoires. Par conséquent, la limitation ou l’exclusion indiquée
précédemment peut ne pas être applicable. Cette garantie vous
donne des droits particuliers et peut-être d’autres, dépendam-
ment des juridictions en vigueur.
S’il n’existe aucune preuve acceptable de la date d’installation, la
durée de la présente garantie sera d’un an à partir de la date de
fabrication. Adresser toute remarque, etc. à : Service Department,
LITTLE GIANT, 301 N. MacArthur, Oklahoma City, OK 73127-6616,
U.S.A.
DÉTERMINATION DE LA DATE DE FABRICATION : (9-87) Le
mois et l’année estampillés sur la pompe ou le numéro de série sur
la plaque du fabricant, codé pour indiqué l’année de fabrication.
GARANTIA LIMITADA
SUMIDERO Y EFLUENTES
Las bombas sumergibles para sumidero y efluente serie ES33
de Little Giant se recomiendan para ser utilizadas en sumideros,
cubetas o estaciones de levante y se pueden utilizar para agua
de drenaje de sótanos, efluentes y aguas residuales y otros líqui-
dos no explosivos o no corrosivos que no estén a más de 60ºC
(140ºF) con capacidad de manejo de sólidos esféricos de hasta
9,5 mm (3/8 de pulg.). (NO SE DEBEN UTILIZAR PARA AGUAS
CLOACALES, EXCEPTO PARA BOMBEAR EL EFLUENTE DE
POZOS SÉPTICOS).
Se garantiza que los productos Little Giant están en perfecto
estado al salir de fábrica. Durante los lapsos establecidos y sujeto
a las estipulaciones que se establezcan de aquí en adelante, la
compañía LITTLE GIANT, una subsidiaria de Franklin Electric
Company, Inc., reparará o reemplazará para el usuario original
o consumidor cualquier porción de su nuevo producto LITTLE
GIANT que demuestre estar defectuoso debido a materiales o
mano de obra de LITTLE GIANT.
Póngase en contacto con su Distribuidor Little Giant para el servicio
de garantía.
En todo momento, LITTLE GIANT tendrá y poseerá el derecho
único y opción para determinar si debe reparar o reemplazar
equipo, piezas o componentes defectuosos. Los daños causados
por rayos o condiciones fuera del control de LITTLE GIANT NO
ESTAN CUBIERTOS POR ESTA GARANTIA.
PERIODO DE GARANTIA
BOMBAS: 12 meses a partir de la fecha de instalación o 18 meses
a partir de la fecha de fabricación, lo que ocurra primero.
MANO DE OBRA, ETC. COSTOS: BAJO NINGUNA
CIRCUNSTANCIA LITTLE GIANT será responsable o estará
expuesto a acción judicial por el costo de mano de obra externa
en el lugar u otros cargos incurridos por cualquier cliente al
extraer o asegurar cualquier producto LITTLE GIANT, pieza o
componente de éste.
ESTA GARANTIA NO SERA APLICABLE:
1. a defectos o funcionamiento defectuoso ocasionados por no
instalar, operar o mantener la unidad conforme a las instruc-
ciones escritas provistas.
2. a fallas causadas por abuso, accidente o negligencia.
3. a servicios normales de mantenimiento y a las piezas utiliza-
das para prestar dichos servicios.
4. a unidades que no se hayan instalado de conformidad con los
códigos, ordenanzas y buenas prácticas comerciales.
5. a la unidad que es utilizada para fines diferentes de aquellos
para los que fue diseñada y fabricada.
6. si la unidad es expuesta, pero sin limitarse, a: arena, grava,
cemento, grasa, yeso, barro, brea, hidrocarburos, o derivados
de hidrocarburos (aceite, gasolina, solventes, etc.) u otras
sustancias abrasivas o corrosivas.
7. si la bomba ha sido utilizada para bombear continuamente
líquidos apropiados a temperaturas superiores a 140°F.
8. el cable cortado a menos de tres pies (0,91 m.).
9. si la bomba ha sido desarmada por el cliente. (Sólo el dis-
tribuidor puede desarmar la bomba para prestarle servicio
externo en el lugar).
11
COMPONENTES QUE DEBEN DEVOLVERSE O REEMPLAZARSE:
Cualquier ítem que deba reemplazarse bajo la Garantía debe
devolverse, flete prepagado, a LITTLE GIANT en Oklahoma City,
OK o a cualquier otro sitio que LITTLE GIANT pueda designar.
MEJORAMIENTO DE LOS PRODUCTOS: LITTLE GIANT se
reserva el derecho de cambiar o mejorar sus productos o
cualquier porción de ellos sin estar obligada a proveer tal cambio
o mejora para las unidades vendidas y/o enviadas antes de tal
cambio o mejora.
RECHAZO: Cualesquiera afirmaciones orales acerca del producto
hechas por el vendedor, el fabricante, los representantes o cualesquiera
otros, no constituyen garantías, no deberán ser objeto de confianza
por parte del usuario, y no son parte del contrato de venta. La
única obligación del vendedor y del fabricante, y el único recurso
del comprador, será el reemplazo y/o la reparación por el fabrican-
te del producto como se describe arriba. Ni el vendedor ni el fab-
ricante serán responsables por cualquier lesión, pérdida o daños,
directos, incidentales o emergentes (incluyendo, pero sin limitarse
a daños incidentales, o emergentes por pérdida de ganancias,
pérdida de ventas, daños a personas o propiedades, o cualesqui-
era otra pérdida incidental o emergente), que surja del uso o de
la incapacidad de usar el producto y el usuario conviene en que
ningún otro recurso estará a su disposición. Antes de utilizar el
producto, el usuario deberá determinar la idoneidad de éste para
el fin propuesto, y el usuario asume todo riesgo de responsabilidad
en relación a dicha utilización. La garantía y recurso descritos en
esta garantía limitada es una garantía EXCLUSIVA y el recurso
es EN LUGAR DE cualquier otra garantía y recursos explícitos
o implícitos, que otras garantías y recursos están expresamente
EXCLUIDOS por el presente documento, incluyendo, pero sin
limitarse a cualquier garantía implícita de COMERCIABILIDAD o
IDONEIDAD PARA UNA FINALIDAD PARTICULAR. Algunos esta-
dos no permiten la exclusión o limitación de daños incidentales
o emergentes, así que la limitación o exclusión arriba indicada
puede que no sea aplicable a usted. Esta garantía le da a usted
derechos legales específicos, y usted puede tener otros derechos
que pueden variar de un estado a otro.
En ausencia de otra prueba apropiada de la fecha de instalación,
la fecha de vigencia de esta garantía se basará en la fecha de
manufactura, más un año. Dirija todas las notificaciones, etc. a:
Service Department, LITTLE GIANT, 301 N. MacArthur, Oklahoma
City, OK 73127-6616.
DETERMINACION DE LA FECHA DE FABRICACION DE LA
UNIDAD: (9-87) el mes y el año estampados en la bomba y/o el
número serial sobre la placa de la bomba codificado para indicar
el año de fabricación.
Form 998557 - 01/2008
© 2007 Franklin Electric Co., Inc.
Little Giant® is a registered trademark of Franklin Electric Co., Inc.
For parts or repair, please contact . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
For technical assistance, please contact . . . . . . . . . . . . . . . 1.888.956.0000
Pour des parties ou la réparation,
entrez s’il vous plaît en contact . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
Pour l’aide technique, entrez s’il vous plaît en contact . . . . 1.888.956.0000
Para partes o la reparación,
por favor póngase en contacto . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933
Para la ayuda técnica, por favor póngase en contacto . . . . 1.888.956.0000
www.LittleGiantPump.com

Transcripción de documentos

Franklin Electric Co., Inc. P. O. Box 12010 Oklahoma City, OK 73157-2010 405.947.2511 • Fax: 405.947.8720 www.LittleGiantPump.com [email protected] EN ES33D1-10, ES33M1-10, ES33V1-10, ES33W1-10, ES33D1-20 ES33M1-20 ES33V1-20 ES33W1-20 U.S. Patent 6,867,383 INTRODUCTION This instruction sheet provides you with the information required to safely own and operate your Little Giant pump. Retain these instructions for future reference. The Little Giant pump you have purchased is of the highest quality workmanship and material, and has been engineered to give you long and reliable service. Little Giant pumps are carefully tested, inspected, and packaged to ensure safe delivery and operation. Please examine your pump carefully to ensure that no damage occurred during shipment. If damage has occurred, please contact the place of purchase. They will assist you in replacement or repair, if required. 1. Read all instructions and safety guidelines thoroughly. Failure to follow the guidelines and instructions could result in serious bodily injury and/or property damage. 2. DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES OR HAZARDOUS LOCATIONS AS CLASSIFIED BY NEC, ANSI/NFPA70. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE. 3. During normal operation the sump pump is immersed in water. Also, during rain storms, water may be present in the surrounding area of the pump. Caution must be used to prevent bodily injury when working near the pump: a. The plug must be removed from the receptacle prior to touching, servicing or repairing the pump. b. To minimize possible fatal electrical shock hazard, extreme care should be used when changing fuses. Do not stand in water while changing fuses or insert your finger into the fuse socket. 4. Do not run the pump in a dry basin. If the pump is run in a dry basin, the surface temperature of the pump will rise to a high level. This high level could cause skin burns if the pump is touched and will cause serious damage to your pump. READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW THE PUMP’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! 5. Do not oil the motor. The pump housing is sealed. A high grade dielectric oil devoid of water has been put into the motor housing at the factory. Use of other oil could cause serious electric shock and/or permanent damage to the pump. DESCRIPTION 6. This pump’s motor housing is filled with a dielectric oil for motor heat transfer and lifetime lubrication of the bear- Little Giant Submersible Sump and Sewage Pumps are recommended for use in basins or lift stations and suitable for pumping non-potable, residential drainage water, effluent, and other non-explosive, non-corrosive liquids. The ES33 pumps have 3/8” spherical solids handling capability. Other accessories such as basins, check valves and covers are also available. E S 3 3D 1 E S 3 3M 1 SAFETY GUIDELINES WARNING: Risk of electric shock. This pump is supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected to a properly grounded, grounding type receptacle. Your pump is equipped with a 3-prong electrical plug. The third prong is to ground the pump to prevent possible electrical shock hazard. Do not remove the third prong from the plug. A separate branch circuit is recommended. Do not use an extension cord. When a pump is in a basin, etc., do not touch motor, pipes or water until unit is unplugged or shut off. If shut-off box is not accessible, call the electric company to shut off service to the house, or call your local fire department for instructions. Failure to follow this warning can result in fatal electrical shock. E S 33V 1 E S 3 3W 1 The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of shortening the cord to fit into a control panel. Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin, and comply with the National Electrical Code. Do not use the power cord for lifting the pump. The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of excessively high or low voltage, inadequate wiring, incorrect motor connections, or a defective motor or pump. Figure 1 1 ings. This oil is non-toxic to aquatic life. However, suffocation can occur if oil is left on the water surface. If oil escapes the motor housing it can be removed from the surface quickly by placing newspapers on the water surface to soak up the oil. TYPICAL INSTALLATION • INSTALLATION TYPE • INSTALACION TIPICA Separate protected and grounded service outlet 4' from floor min. Prise de courant de mise à la terre à protection séparée à une distance minimale de 4 pi du sol Tomacorrientes de servicio conectado a tierra y protegido separado por lo menos a 4 pies del suelo Figure 2 7. In any installations where property damage and/or personal injury might result from an inoperative or leaking pump due to power outages, discharge line blockage, or any other reason, a backup system(s) and/or alarm should be used. Wall Mur Pump power cord Cordon d'alimentation de la pompe Cable de potencia de la bomba Discharge pipe no smaller than pump outlet La canalisation de refoulement doit étre plus petite que la sortie de pompe Tubo de descarga que no sea más pequeño que la salida de la bomba Gate valve Clapet de la vanne Válvula de la compuerta Union Check valve Raccord Clapet de retenue Unión Verifique válvula 2" or 3" vent pipe Canalisation de ventilation de 2 ou 3 po Tubo de ventilación 2" ó 3" OPERATION Power cord grommet Oeillet du cordon d'alimentation Anillo protector del cable de potencia TESTING PUMP OPERATION ES33 SERIES SUMP PUMPS: 1. All pumps except ES33M are equipped with an automatic switch. Pump must be plugged into switch for automatic operation. 2. When these pumps are installed in a basin with a sealed cover, switch operation cannot be observed. The sump cover usually will have a spare hole that is plugged with a rubber plug. This plug can be removed and switch operation can be observed. 3. Plug power cord into a grounded receptacle with voltage consistent with pump voltage as indicated on pump nameplate. 4. Run water into basin until pump starts. 5. Be sure gate valve in discharge line is open. 6. Allow pump on-off cycles. to operate Basin cover Couvercle du bassin Tapa del recipiente Power cord taped to pipe Fil d'alimentation collé au tuyau avec un ruban Cordón eléctrico sujeto a la tubería con cinta adhesiva Gas tight basin 18" dia. x 22" deep min. Bassin anatibactérien d'un diamètre minimal compris entre 18 po et 22 po Recipiente hermético al gas de 18" diámetro y de un mínimo de 22" de profundidad 3/16" dia. bleed hole in discharge pipe Trou de dégagement diam. 3/16 po sur le tuyau d'écoulement Agujero de purgado de 3/16" de diámetro en la tubería de descarga Place pump on hard level surface. Never place directly on clay, earth or gravel surface. 3.5" tether length La pompe doit être installée sur une surface dure. N'installez jamais la pompe sur une surface argileuse, terreuse ou sableuse. Fil de l'interrupteur: 3.5 po Posicione la bomba sobre una superficie dura y nivelada y nunca Prisionero de 3.5" posicione la bomba directamente sobre superficies de arcilla, tierra o grave. through several MAINTENANCE If pump does not operate properly, consult the troubleshooting chart. If trouble cannot be located with these steps shown, consult your pump dealer or take pump to a Little Giant authorized service center. CAUTION: When working on pump or switch, always unplug pump power cord in addition to removing fuse or shutting off circuit breaker before working on pump. CLEANING IMPELLER AND VOLUTE 1. Remove (8) screws that hold screen to volute, and volute to motor housing. 2. Remove volute and clean impeller and volute passage. Do not use strong solvents on impeller. 3. Be sure impeller turns freely after cleaning. 4. WARNING: DO NOT REMOVE IMPELLER. REMOVAL OF IMPELLER REQUIRES SPECIAL TOOLS AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER. DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY IS VOID IF MOTOR HOUSING COVER, IMPELLER OR SEALS HAVE BEEN REMOVED. ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED LITTLE GIANT SERVICE CENTER. MODEL NO. ES33 LISTING CSA/cCSAus *20’ cord optional 2 HP 1/3 VOLTS 115 ES33D1: 10"–12" on level • 10 po à 12 po à niveau • 10" a 12" en el nivel ES33V1: 5"–6" on level • 5 po à 6 po à niveau • 5" a 6" en el nivel ES33W1: 10"–12" on level • 10 po à 12 po à niveau • 10" a 12" en el nivel SOLIDS SIZE (dia. AMPS/ in.) WATTS 3/8” 5/475 ES33D1: 4"–6" off level • 4 po à 6 po hors niveau • 4" a 6" fuera del nivel ES33V1: 2" off level • 2 po hors niveau • 2" fuera del nivel ES33W1: 8"–10" off level • 8 po à 10 po hors niveau • 8" a 10" fuera del nivel SPECIFICATIONS Discharge Size: Intake Size: Horsepower: Pump Housing: Volute: Screen: Impeller: Motor: 1-1/2” NPT vertical 3/8” screened opening 1/3 HP Cast iron Plastic Plastic Plastic vortex design Single phase permanent split capacitor with automatic reset thermal overload protection. Hardware: 300 Series stainless steel Bearings: Ball bottom, sleeve top Pump Shaft Seal: Mechanical, spring loaded, stationary carbon with Nitrile boot and rotating ceramic seat. Power Cord: 16 AWG 3-conductor, copper, stranded, 10’ or 12’ length Cooling: The motor housing contains a cooling oil to provide cooling for the motor and to lubricate bearings and seals. These pumps are capable of operating with the motor housing partially exposed for extended periods of time, providing sufficient motor cooling and bearing lubrication. However, for the best cooling and longest motor life, the liquid level being pumped should normally be above the top of the cast iron motor housing. GPM @ HEAD 5’ 10’ 15’ 20’ 57 40 28 0 SHUT OFF 20 P.S.I. 8.6 PWR. CORD (ft.) 10* WT. (Lbs.) 30 INSTALLATION Pump must be installed in a suitable gas tight basin which is at least 18” in diameter and 24” deep. The ES33 Series pumps feature a 1/3 HP, 1-1/2” female NPT discharge. Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe. Proper adapters are required to connect plastic pipe to pump. Pump must be placed on a hard level surface. Never place pump directly on clay, earth or gravel surfaces. A check valve must be used in the discharge line to prevent back flow of liquid into the basin. The check valve should be a free flow valve that will easily pass solids. CAUTION: For best performance of check valves, when handling solids install in a horizontal position or at an angle of no more than 45°. Do not install check valve in a vertical position as solids may settle in valve and prevent opening on start-up. When a check valve is used, drill a relief hole (1/8” or 3/16” diameter) in the discharge pipe. This hole should be located below the floor line between the pump discharge and the check valve. Unless such a relief hole is provided, the pump could “air lock” and will not pump water even though it will run. WIRING Check local electrical and building codes before installation. The installation must be in accordance with their regulations as well as the most recent National Electrical Code (NEC). To conform to the National Electrical Code all pumps must be wired with 14 AWG or larger wire. For runs to 250 feet 14 AWG wire is sufficient. For longer runs consult a qualified electrician or the factory. Pump should be connected or wired to its own circuit with no other outlets or equipment in the circuit line.Fuses and circuit breaker should be of ample capacity in the electrical circuit (see chart below). H.P. 1/3 VOLTAGE 115 FR MINIMUM FUSE OR CIRCUIT BREAKER AMPS 15 INTRODUCTION et d’autres liquides non explosifs et non corrosifs. Les pompes ES33 peuvent pomper des matières solides sphériques de 9 mm (3/8 po). D’autres accessoires comme des bassins, des clapets anti-retour et des couvercles sont également disponibles. DIRECTIVES DE SECURITE AVERTISSEMENT : Danger d’électrocution. Cette pompe est équipée d’un conducteur de terre et d’une prise de terre mâle. Pour éviter tout danger d’électrocution, s’assurer que la prise est connectée à une prise de courant bipolaire plus terre. Votre pompe est dotée d’une fiche à trois branches. La troisième branche a pour fonction de mettre la pompe à la terre afin de prévenir tout choc électrique. Ne pas couper cette troisième branche. Il est recommandé de brancher la pompe à un circuit indépendant. Éviter d’utiliser une rallonge. Lorsqu’une pompe est dans un réservoir, éviter de toucher au moteur, aux tuyaux ou à l’eau si la pompe n’est pas débranchée ou hors tension. Si le panneau électrique n’est pas accessible, communiquer avec votre compagnie d’électricité pour qu’elle coupe l’alimentation de la maison, ou avec votre service d’incendie pour connaître la marche à suivre dans ces circonstances. Le non-respect de cet avertissement pourrait résulter en un choc électrique fatal. Le fil d’alimentation flexible de la pompe, gainé de ne doit être modifié d’aucune façon, sauf pour être raccourci afin qu’il entre dans un panneau de commande. Toute épissure entre la pompe et le panneau de commande doit être faite à l’intérieur d’une boîte d’accouplement et installée hors du réservoir; elle doit aussi être conforme au Code national de l’électricité. Ne pas soulever la pompe à l’aide du fil d’alimentation. Le moteur de la pompe est pourvu d’un dispositif de protection thermique à démarrage automatique ; elle peut redémarrer à tout moment. Le déclenchement du dispositif de protection indique une surchauffe du moteur provoquée par un voltage excessif ou insuffisant, un câblage non approprié, des erreurs de raccordement du moteur, une défaillance du moteur ou une défaillance de la pompe. Cette feuille d’instructions vous fournit les informations nécessaires pour entretenir et faire fonctionner votre produit Little Giant. Conserver ces directives afin de pouvoir les consulter plus tard. 1. Bien lire les instructions du guide de sécurité. Le non-respect des consignes de sécurité peut causer de graves blessures ou des dommages à la propriété, ou les deux. Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec des matériaux de la plus haute qualité et a été conçu pour durer longtemps et offrir un service fiable. Les produits Little Giant sont soigneusement testés, inspectés et emballés afin d’en assurer la sécurité de fonctionnement et une livraison en bonne condition. Vérifier attentivement le produit afin de vous assurer qu’il n’a pas été endommagé pendant le transport. S’il est endommagé, veuillez contacter l’entreprise qui vous l’a vendu. Si une réparation ou un remplacement est requis, elle vous prêtera assistance. 2. Ne pas utiliser pour pomper des liquides explosifs ou inflammables (essence, huile, kérosène, etc.) Ne pas utiliser dans des environnements explosifs ou des lieux considérés comme dangereux (voir Code nat. de l’Élect., ANSI/NFPA70). Le non-respect de cette mesure de sécurité peut causer des dommages ou des blessures. LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À L’INSTALLATION, À L’UTILISATION OU À L’ENTRETIEN DU PRODUIT LITTLE GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES ET LES RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES DE SÉCURITÉ. LE NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER DES BLESSURES ET/OU DES DOMMAGES MATÉRIELS! DESCRIPTION Les pompes submersibles à puisard de Little Giant sont recommandées pour les bassins et les stations de pompage et sont conçues pour eau de drainage non-potable, résidentielle de pompage, effluent 3. Durant le fonctionnement normal du système, la pompe à puisard est immergée, donc invisible. De plus, pendant les orages, il pourrait y avoir de l’eau autour de la pompe. C’est pourquoi il faut faire attention si on travaille près de celle-ci. a. Débrancher la pompe avant d’y toucher ou d’en faire l’entretien ou la réparation. b. Afin de réduire le risque d’électrocution, faire preuve d’une grande prudence pendant le remplacement des fusibles. Ne pas avoir les pieds dans l’eau pendant le remplacement des fusibles et ne pas insérer le doigt dans les culots de fusibles. 4. Ne pas faire fonctionner la pompe dans un réservoir à sec. Si cela se produisait, la température de surface de la pompe deviendrait assez élevée pour causer de graves brûlures et endommager sérieusement la pompe. 3 5. Ne pas lubrifier le moteur. Le boîtier de la pompe est scellé. De l’huile diélectrique de haute qualité sans eau a été mise dans le boîtier en usine. L’utilisation d’un autre type d’huile pourrait causer un choc électrique grave ou gravement endommager la pompe, ou les deux. 6. Le boîtier du moteur de cette pompe est rempli d’une huile diélectrique, pour un transfert de chaleur optimal et une lubrification durable des paliers. Cette huile n’est d’aucun danger pour la vie aquatique. Il y a toutefois risque de suffocation si l’huile reste à la surface de l’eau. S’il devait y avoir fuite, retirer l’huile de la surface en plaçant du papier journal sur l’eau afin d’absorber l’huile. 7. L’utilisation d’un ou de plusieurs systèmes auxiliaires et/ou d’un système d’alarme est recommandée pour toute installation potentiellement dangereuse (fuite ou défectuosité causées par une coupure de courant, un blocage du circuit de refoulement ou pour toute autre raison) pour les personnes ou la propriëtë. CARACTÉRISTIQUES TECHNIQUES Taille D’écoulement Taille D’aspiration : Chevaux-vapeur : Boîtier de la pompe : Volute : Grille : Turbine : Moteur : Attaches. : Roulements : Joint étanche de l’arbre du moteur : FONCTIONNEMENT VÉRIFICATION DU FONCTIONNEMENT DE LA POMPE POMPES À PUISARD DE SÉRIE ES33 : 1. Toutes les pompes sauf ES33M sont équipées d’un interrupteur automatique. La pompe doit être branchée dans le commutateur pour l’opération automatique. 2. Lorsque ces pompes sont installées dans bassin avec un couvercle scellé, le fonctionnement du commutateur ne peut être observé. Le couvercle du puisard comporte généralement un trou supplémentaire obstrué par un bouchon en caoutchouc. Ce bouchon peut être enlevé pour observer le fonctionnement du commutateur. 3. Brancher les fils d’alimentation de la pompe et de l’interrupteur dans une prise mise à la terre en s’assurant que la tension de celleci correspond à la tension indiquée sur la plaque signalétique. 4. Remplir le réservoir d’eau jusqu’à ce que la pompe se mette en marche. 5. S’assurer que la vanne à obturateur du conduit de sortie est ouverte. 6. Laisser la pompe s’allumer et s’éteindre à plusieurs reprises. ENTRETIEN Si la pompe ne fonctionne pas convenablement, consultez le tableau de relève des dérangements. Si vous pouvez identifier le problème en suivant les étapes indiquées, consultez le fournisseur de votre pompe ou rapportez la pompe à un centre de service autorisé Little Giant. MISE EN GARDE : Avant tout entretien ou réparation effectué sur la pompe ou l’interrupteur, toujours débrancher la pompe et retirer le fusible (ou déclencher le disjoncteur). NETTOYAGE DE LA TURBINE ET DE LA VOLUTE 1. Enlever les vis qui retiennent le grillage à la volute et la volute au boîtier du moteur. 2. Retirer la volute et nettoyer la turbine ainsi que le passage de la volute. Éviter d’utiliser de puissants solvants sur la turbine. 3. Veillez à ce que la turbine tourne librement une fois le nettoyage terminé. 4. AVERTISSEMENT : LAISSEZ LA TURBINE EN PLACE. LE RETRAIT DE LA TURBINE NÉCESSITE DES OUTILS SPÉCIAUX ET NE PEUT ÊTRE EFFECTUÉ QU À UN CENTRE DE SERVICE AUTORISÉ. LAISSER LE COUVERCLE DU BOÎTIER DU MOTEUR EN PLACE. LE RETRAIT DU COUVERCLE DU BOÎTIER DU MOTEUR, DE LA TURBINE OU DES JOINTS ANNULE LA GARANTIE. TOUTE RÉPARATION DU MOTEUR DOIT ÊTRE EFFECTUÉE À UN CENTRE DE SERVICE AUTORISÉ LITTLE GIANT . 4 Cordon d’alimentation : Refroidissement : : 1-1/2” po NPT Vertical Ouverture grillagée de 3/8” po 1/3 Ch Fonte Plástico Plástico Conception avec vortex en plastique Condensateur auxiliaire permanent monophasé avec protecteur thermique à réenclenchement automatique Acier inoxydable, série 300 Bille à la base, manchon sur le dessus Contacteur mécanique à ressort, carbone fixe avec enveloppe en nitrile et siège rotatif en céramique 16 AWG 3 conducteurs, cuivre, à torons, 3 ou 3,65 m (10 ou 12 pieds) de long Le boîtier du moteur renferme une huile de refroidissement pour le moteur, qui lubrifiera aussi les paliers et les joints d’étanchéité. Même si le boîtier du moteur était partiellement exposé, ces pompes pourraient fonctionner pour de longues périodes de temps, à condition que le refroidissement et la lubrification soient adéquats. Toutefois, il est recommandé que le niveau du liquide à pomper soit audessus du boîtier de fonte afin d’assurer le meilleur refroidissement possible et de prolonger la durée de vie du moteur. INSTALLATION La pompe doit être installée dans un bassin approprié, étanche au gaz et mesurant au moins 46 cm (18 po) de diamètre et 61 cm (24 po) de profondeur. Les pompes de série ES33 possèdent une évacuation femelle de 1½ po de type NPT, de 1/3 HP. La pompe peut être installée avec des tuyaux d’acier galvanisé, de polyéthylène, d’ABS ou de PVC. Des adaptateurs sont requis pour raccorder le tuyau de plastique à la pompe. La pompe doit être placée sur une surface plate et dure. Ne jamais placer la pompe directement sur de l’argile, de la terre ou des surfaces en concassé. Un clapet de retenue doit être placé dans la conduite de sortie afin de prévenir tout reflux de liquide à l’intérieur du réservoir. Le clapet devrait être à flot libre et pouvoir laisser passer des matières solides. MISE EN GARDE : Afin d’obtenir une performance maximale des clapets de retenue pendant le pompage de matières solides, installer les clapets à l’horizontale ou à un angle ne dépassant pas 45°. Éviter de les installer à la verticale, car des matières solides pourraient rester coincées dans le clapet et empêcher son ouverture lors de la mise en marche de la pompe. Dans ce cas, percer dans le tuyau d’écoulement un trou de dégagement d’un diamètre de 1/8 po à 3/16 po, en-dessous du sol entre l’écoulement de la pompe et la soupape d’arrêt pour éviter qu “un bouchon d’air” se produise qui empêcherait l’appareil de pomper même s’il fonctionnait normalement. CÂBLAGE Vérifier les codes locaux de l’électricité et du bâtiment avant l’installation. Celle-ci devrait être conforme avec ces règlements ainsi qu’avec le plus récent Code national de l’Électricité. Afin de respecter les exigences du Code national de l’Électricité, toute les pompes doivent être branchées avec du fil #14 AWG ou plus gros. Pour des longueurs de fils inférieures à 250 pi, un fil #14 AWG convient. Consulter un électricien ou l’usine pour des longueurs plus élevées. La pompe devrait être branchée à un circuit indépendant. Aucun autre appareil ne devrait être branché à ce circuit, et les fusibles et disjoncteurs devraient être de capacité adéquate. Consulter le tableau ci-dessous. Ch VOLTAGE AMPÉRAGE MINIMUM DU FUSIBLE OU DU DISJONCTEUR 1/3 115 15 ES INTRODUCCIÓN Esta hoja de instrucciones le proporciona la información requerida para tener y operar de forma segura su producto Little Giant. Guarde las instrucciones para referencia futura. El producto Little Giant que ha adquirido se fabrica utilizando mano de obra y materiales de la más alta calidad y ha sido diseñado para prestarle un servicio duradero y confiable. Los productos Little Giant son cuidadosamente probados, inspeccionados y empacados para garantizarle una entrega y operación seguras. Examine su unidad cuidadosamente para asegurarse de que no haya ocurrido ningún daño durante el transporte. Si se ha presentado algún daño, comuníquese con el lugar de compra. Deberán darle asistencia para obtener la reparación o reemplazo, si se requiere. LEA ESTAS INSTRUCCIONES CUIDADOSAMENTE ANTES DE INTENTAR INSTALAR, HACER FUNCIONAR O PRESTAR SERVICIO TÉCNICO A SU PRODUCTO LITTLE GIANT. CONOZCA CUÁLES SON LAS APLICACIONES, LIMITACIONES Y PELIGROS POTENCIALES DE LA UNIDAD. PROTEJA A TERCEROS Y PROTÉJASE A USTED MISMO SIGUIENDO TODA LA INFORMACIÓN DE SEGURIDAD. ¡LA FALTA DE CUMPLIMIENTO DE ESTAS INSTRUCCIONES PUEDE PRODUCIR LESIONES PERSONALES Y/O DAÑOS A LA PROPIEDAD! DESCRIPTION Las bombas sumergibles Little Giant para sumideros y aguas cloacales se recomiendan para bombear agua de drenaje no potable, residencial, efluente, y otros líquidos que no sean explosivos o corrosivos. Las bombas ES33 cuentan con la capacidad de manejar desechos sólidos esféricos de 9,5 mm (3/8 pulg.). También hay otros accesorios disponibles, como cubetas, válvulas de retención y tapas. NORMAS DE SEGURIDAD ADVERTENCIA: PELIGRO DE CHOQUE ELÉCTRICO. Esta bomba está dotada de un cable de puesta tierra y un enchufe accesorio de puesta a tierra. Para reducir el riesgo de choque eléctrico, cerciórese de que se encuentre conectada a un receptáculo del tipo de puesta a tierra, debidamente puesto a tierra. Su bomba está dotada de un enchufe eléctrico de tres dientes. El tercer diente es para ponerla a tierra, con el fin de evitar el riesgo de posibles choques eléctricos. No quite el tercer diente del enchufe. Se recomienda un circuito de ramal independiente. No utilice un cable de extensión. Cuando la bomba se encuentre en un dique seco, etc., no toque el motor, los tubos ni el agua, mientras no se encuentre desconectada o apagada. Si hay agua o humedad en sus instalaciones, no toque el área húmeda mientras no se haya cortado toda la electricidad. Si la caja de interruptores no está accesible, llame a la compañía de electricidad para que interrumpa el servicio a la casa, o pida instrucciones al departamento local de bomberos. El hacer caso omiso de esta advertencia, puede producir un choque eléctrico mortal. El conjunto de cables flexibles con manguito de cloruro polivinílico montado en la bomba, no debe modificarse de ninguna manera, salvo para acortar el cable, con el fin de ajustarlo a un tablero de mandos. Cualquier empalme entre la bomba y el tablero de mandos debe efectuarse dentro de una caja de conexiones y montarse fuera del dique seco. Además, debe ajustarse al Código Eléctrico Nacional. No utilice el cable eléctrico para levantar la bomba. El motor de la bomba está equipado con un protector térmico de reposición automática y puede reposicionarse inesperadamente. El accionamiento del protector es una indicación de sobrecarga del motor debida a un voltaje demasiado alto o bajo, un cableado inadecuado, conexiones de motor incorrectas o un motor o bomba defectuosos. 1. Lea todo el instructivo, el no seguir estas recomendaciones puede causar serios daños a la persona y al equipo. 2. NO USE LA UNIDAD PARA BOMBEAR LIQUIDOS INFLAMABLES NI EXPLOSIVOS TALES COMO GASOLINA, FUELOIL, QUEROSENO, ETC. NO SE USE EN AMBIENTES EXPLOSIVOS O LUGARES EPLIGROSOS, SEGUN LA CLASIFICACION DEL CODIGO ELECTRICO NACIONAL (NEC) Y LA NORMA NFPA70 DEL INSTITUTO NACIONAL NORTEAMERICANO DE NORMAS. EL HACER CASO OMISO DE ESTA ADVERTENCIA, PUEDE TRAER COMO RESULTADO LESIONES CORPORALES, DAÑOS MATERIALES O AMBOS. 3. Durante el funcionamiento normal la bomba de sumidero está inmersa en agua. Además, durante las tormentas, puede haber agua en el área circundante de la bomba. Se debe observar precaución para prevenir lesiones personales al trabajar cerca de la bomba. a. Debe sacarse el enchufe de la toma de corriente, antes de tocar, limpiar o reparar la bomba. b. Para disminuir el riesgo de choques eléctricos posiblemente fatales, tenga sumo cuidado al cambiar los fusibles. No pise agua mientras cambia los fusibles ni introduzca el dedo en el receptáculo del fusible. 4. No haga funcionar la bomba en un depósito seco. Si la bomba es operada en un depósito seco, la temperatura de la superficie de la bomba se elevará a un alto nivel. Este alto nivel podría causar quemaduras de la piel si se toca la bomba y puede causar daños graves a la bomba. 5. No engrase el motor. La caja de la bomba está sellada. Desde la fábrica se ha colocado un aceite dieléctrico de alto grado y repelente al agua dentro de la carcasa del motor. El uso de otro tipo de aceite podría causar daños eléctricos graves y/o daños permanentes a la bomba. 6. El alojamiento del motor de esta bomba está lleno con un aceite dieléctrico para la transferencia de calor y la lubricación de por vida de los cojinetes. Este aceite no es tóxico para la vida acuática. Sin embargo, puede ocurrir la muerte de ésta, si el aceite queda sobre la superficie. Para quitar rápidamente el aceite que pueda haberse escapado del alojamiento del motor, coloque periódicos sobre la superficie del agua para absorber el aceite. 7. EN CUALQUIER INSTALACION DONDE PUEDAN OCURRIR DAÑOS MATERIALES Y/O LESIONES PERSONALES QUE RESULTEN DEL FUNCIONAMIENTO INADECUADO O DE FUGAS EN LA BOMBA A CAUSA DE FALLOS EN LA ALIMENTACION ELECTRICA, BLOQUEO DE LA LINEA DE LA DESCARGA, O CUALQUIER OTRA RAZON, SE DEBERA USAR UNO O VARIOS SISTEMAS DE RESPALDO Y/O ALARMAS. 5 FUNCIONAMIENTO PROBAR EL FUNCIONAMIENTO DE LA BOMBA BOMBAS PARA SUMIDERO SERIE ES33: de reestablecimiento automático Piezas Metalicas: Serie 300, de acero inoxidable Cojinetes: Inferior bola, superior manguito 1. Todas las bombas excepto ES33M son equipadas con un interruptor automático. La bomba debe ser enchufada el interruptor para la operación automática. Sello del eje de la bomba: 2. Al instalar estas bombas en una cubeta con la tapa sellada, no se puede observar el funcionamiento del interruptor. La tapa de la bomba generalmente cuenta con un orificio cubierto con un tapón de caucho. Este tapón se puede retirar para observar el funcionamiento del interruptor. Cable de potencia: Calibre 16 de 3 hilos de cobre, trenzado de 3 ó 3,6 metros (10 ó 12 pies) de largo Enfriamiento: 3. Conecte el cable eléctrico del interruptor de control remoto accionado por un flotador a un receptáculo puesto a tierra, con un voltaje similar al de la bomba, como se indica en la placa del fabricante de la bomba. Conecte el cable eléctrico de la bomba en el enchufe del interruptor de control remoto, accionado por el flotador. 4. Haga correr agua en la bomba, hasta que la bomba arranque. 5. Cerciórese de que la válvula de paso directo del tubero de descarga se encuentre abierta. 6. Permite que la bomba funcione durante varios ciclos de apagado y encendido. MANTENIMIENTO Si la bomba no funciona apropiadamente, consulte el plano de investigación de averías. Si no puede encontrar el problema siguiendo estos pasos, consulte al distribuidor de la bomba o lleve la bomba a un centro de servicio autorizado de Little Giant. PRECAUCION: Cuando trabaje en la bomba o en el interruptor, desconecte siempre el cable eléctrico, además de quitar el fusible o apagar el interruptor automítico, antes de trabajar en la bomba. LIMPIEZA DEL ROTOR Y EL DIFUSOR 1. Retire los tornillos que sujetan la malla al espiral y el espiral al alojamiento del motor. 2. Limpie el rotor y el conducto del difusor. No utilice detergentes fuertes en el impulsor. 3. Asegúrese de que el impulsor gire libremente antes de limpiarlo. 4. ADVERTENCIA: NO QUITE EL IMPULSOR. PARA QUITAR EL IMPULSOR SE REQUIEREN HERRAMIENTAS ESPECIALES Y ESTO DEBE HACERSE SOLO EN UN CENTRO DE SERVICIO AUTORIZADO. NO QUITE LA CUBIERTA DE LA CAJA DEL MOTOR. LA GARANTIA ES NULA SI SE QUITA LA CUBIERTA DE LA CAJA DEL MOTOR, EL IMPULSOR O LOS OBTURADORES. CUALQUIER REPARACION DEL MOTOR DEBE HACERSE EN UN CENTRO DE SERVICIO AUTORIZADO DE LITTLE GIANT. Tamaño de la Descarga: ESPECIFICACIONES 1-1/2” NPT Vertical Tamaño de la Toma: abertura de 3/8” pulgadas de diámetro Caballos de fuerza: 1/3 KP Bastidor de la bomba: Hierro colado Voluta: Plástico Difusor: Plástico Propulsor: Diseño de vórtex de plástico Motores: Capacitor con división permanente monofásico con protección contra sobrecarga térmica 6 Carbón estacionario, mecánico y cargado con resorte con protector de nitrilo y base giratoria de cerámica El estator contiene un aceite refrigerante para enfriar el motor y lubricar los cojinetes y obturadores. Estas bombas pueden funcionar largo tiempo con el estator parcialmente expuesto, siempre y cuando el refrigerante del motor y la lubricación de los cojinetes sea sulficiente. No obstante, para un enfriamiento óptimo y una vida máxima del motor, el nivel del líquido que se bombee, normalmente debe encontrarse por encima del estator de hierro colado. INSTALACION La bomba se debe instalar en una cubeta apropiada, hermética al gas, que tenga por lo menos 45,7 cm (18 pulg.) de diámetro y 61 cm (24 pulg.) de profundidad. Las bombas serie ES33 incluyen una descarga NPT hembra de 1 ½ pulg. (38,1 mm) de 1/3 HP. La bomba puede instalarse con tubos ABS, de cloruro polivinílico (PVC) o de acero galvanizado. Para conectar el tubo plástico a la bomba, se requieren adaptadores apropiados. La bomba debe colocarse en una superficie dura y nivelada. No la coloque nunca directamente sobre superficies de arcilla, tierra o grava. Debe utilizarse una válvula de retención en el tubo de descarga, para evitar el reflujo en el dique seco. La válvula de retención debe ser una válvula sin estrangulación, que permita pasar fácilmente cuerpos sólidos. Cuando se utilice una válvula de retención, perfórese un agujero de descompresión (de un diámetro de 1/8 ó 3/16 de pulgada) en el tubo de descarga. Este agujero deberá encontrarse debajo de la línea de la superficie del suelo, entre la descarga de la bomba y la válvula de retención. A menos que se proporcione tal agujero de descompresión, la bomba podría llenarse de burbujas de aire y no bombeará el agua, aunque sí funcionará. CABLES Estudie las normas locales sobre electricidad y construcción, antes de instalar los cables. La instalación debe ajustarse a sus regulaciones así como a las del Código Eléctrico Nacional (NEC) más reciente. Para ajustarse a las disposiciones del Código Eléctrico Nacional, todas las bombas deben tener cables 14 AWG o mayores. Para recorridos 250 pies, basta el cable de 14 AWG. Para recorridos mayores, consulte a un electricista competente o a la fábrica. La bomba debe enchufarse o conectarse en su propio circuito, sin otras tomas o equipos en la línea del circuito. Los fusibles e interruptores automíticos del circuito eléctrico deben ser de gran capacidad. Remítase al siguiente cuadro: KP VOLTIOS AMPERIOS MÍNIMOS DEL FUSIBLE O CORTACIRCUITO 1/3 115 15 Figure 3 REPLACEMENT PARTS • PIÈCES DE RECHANGE • PIEZAS DE REEMPLAZO ITEM ARTICLE ELEMENTO 1 2 3 4A 4B 4C 5A 5B 5C 5D 5E 5F 6 7 8 9 DESCRIPTION • DESCRIPTION • DESCRIPCIÓN Pump Lifting Ring, 2.72” Dia. Plated Steel Anneau de levage de la pompe, en acier plaqué de 6,9 cm (2,72 po) de dia. Anillo para levantar la bomba, diámetro de 69 mm (2,72 pulg.) Acero enchapado Washer, #10 Lock, 410SS Rondelle de blocage, no 10, 410 inox. Arandela de seguridad Nº 10, 410SS Screw, #10 x 3/8”, Pan Head, Phillips Drive Vis, no 10 x 3/8 po, tête cylindrique bombée, cruciforme Tornillo Phillips de cabeza Pan Nº 10 x 9,53 mm (3/8 de pulg.) Bracket, Mounting, SS, “ES33D” Series Support de montage, inox, de série « ES33D » Soporte de montaje de acero inoxidable, serie “ES33D” Bracket, Mounting, SS, “ES33V” Series Support de montage, inox, de série « ES33V » Soporte de montaje de acero inoxidable, serie “ES33V” Clamp, Loop, Strain Relief, Nylon Collier de cadre, de réduction de tension, nylon Abrazadera de bucle de nilón para alivio de presión Piggyback Switch, “ES33D”, 6” Vertical Diaphragm, 10ft, 115VAC Interrupteur avec fiche jumelle, « ES33D », diaphragme vertical de 15,2 cm (6 po), 3 m (10 pi), 115 V c.a. Interruptor en cascada, “ES33D”, diafragma vertical de 152,4 mm (6 pulg.), 3 metros (10 pies) 115 VCA Piggyback Switch, “ES33V” 3” Vertical Mechanical, 10ft, 115VAC Interrupteur avec fiche jumelle, « ES33V », diaphragme mécanique de 7,6 cm (3 po), 3 m (10 pi), 115 V c.a. Interruptor en cascada, “ES33V”, mecánico vertical de 76,2 mm (3 pulg.), 3 metros (10 pies) 115 VCA Piggyback Switch, “ES33W” Wide Angle Float, 10ft, 115VAC Interrupteur avec fiche jumelle, à flotteur grand-angle « ES33W », 3 m (10 pi), 115 V c.a. Interruptor en cascada, “ES33W”, flotador de ángulo amplio, 3 metros (10 pies) 115 VCA Piggyback Switch, “ES33D” 6” Vertical Diaphragm, 20ft, 115VAC Interrupteur avec fiche jumelle, « ES33D », diaphragme vertical de 15,2 cm (6 po), 6 m (20 pi), 115 V c.a. Interruptor en cascada, “ES33D”, diafragma vertical de 152,4 mm (6 pulg.), 6 metros (20 pies) 115 VCA Piggyback Switch, “ES33V” 3” Vertical Mechanical, 20ft, 115VAC Interrupteur avec fiche jumelle, « ES33V », vertical, mécanique de 7,6 cm (3 po), 6 m (20 pi), 115 V c.a. Interruptor en cascada, “ES33V”, mecánico vertical de 76,2 mm (3 pulg.), 6 metros (20 pies) 115 VCA Piggyback Switch, “ES33W” Wide Angle Float, 20ft, 115VAC Interrupteur avec fiche jumelle, à flotteur grand-angle « ES33W », 6 m (20 pi), 115 V c.a. Interruptor en cascada, “ES33W”, flotador de ángulo amplio, 6 metros (20 pies) 115 VCA Seal Ring, Nitrile, Formed, ES33 Volute Bague d’étanchéité, nitrile, formée, volute ES33 Anillo de sello de nitrilo formado, espiral ES33 Volute, ES33, Black Volute, ES33, noire Espiral ES33 negro Base, Screen, ES33, Black Base, grillage, ES33, noire Base de rejilla ES33 negra Screw, 10-32 x 2.38”, SS, Phillips Pan Head Vis, no 10-32 x 2,38 po, inox, cruciforme, tête cylindrique bombée Tonillo Phillips de cabeza Pan Nº 10-32 x 60,5 mm (2,38 pulg.) de acero inoxidable PART No. No DE PIÈCE Nº DE PIEZA 106437 921023 902525 170263 170265 927027 106002 950010 950011 106001 950012 950013 928070 106438 106434 902524 7 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX • PROBLEMA PROBABLE CAUSES • CAUSES PROBABLES • CAUSAS PROBABLES CORRECTIVE ACTION • SOLUTIONS • SOLUCION Pump not plugged in. • La pompe n’est pas branchée. • La bomba Plug in pump. • Branchez le puisard. • Enchufar la bomba. no está enchufada. Pump does not turn on. • La pompe ne peut être mise sous tension. • La bomba no se activa. Pump will not shut off. • Le moteur de la pompe ne s’arrête pas. • La bomba no se apaga. Pump runs but does not discharge liquid. • La pompe fonctionne mais il n’y a pas d’écoulement de liquide. • La bomba funciona, pero no descarga líquido. Circuit breaker shutoff or fuse removed. • Disjoncteur coupé ou fusible enlevé. • Desactivación del disyuntor o se ha retirado el fusible. Turn on circuit breaker or replace fuse. • Mettez le disjoncteur sous tension ou remplacez le fusible. • Active el disyuntor o reemplace el fusible. Accumulation of trash on switch. • Accumulation de débris sur le interrupteur. • Acumulación de desperdicios en el interruptor. Clean switch. • Nettoyez le interrupteur. • Limpie el interruptor. Switch obstruction. • Interrupteur bloqué. • Obstrucción del interruptor. Check switch path and provide clearance. • Vérifiez la voie de passage du interrupteur et dégagez-la au besoin. • Verifique el interruptor y proporcione espacio limpio. Defective motor. • Moteur défectueux. • Motor defectuoso. Have pump serviced by authorized service center. • Faites réparer la pompe à un centre de service autorisé. • Lleve la bomba a un centro de servicio autorizado. Switch obstruction. • Interrupteur bloqué. • Obstrucción del interruptor. Check switch path and provide clearance. • Vérifiez la voie de passage du interrupteur et dégagez-la au besoin. • Verifique el interruptor y proporcione espacio limpio. Pump is air locked. • Poche d’air dans la pompe. • Burbujas de aire en la bomba. Shut power off for approximately 1 minute, then restart. Repeat several times to clear air from pump. • Couper le courant pendant 1 minute environ puis recommencer. Répéter cette opération plusieurs fois pour évacuer l’air de la pompe. • Desconecte la electricidad durante un minuto, aproximadamente. Luego, vuélvala a conectar. Repita varias veces, para purgar el aire de la bomba. Liquid inflow matches pump capacity. • Afflux de liquide correspondant au volume de la pompe. • El caudal que entra es igual a la capacidad de la bomba. Larger pump required. • Une pompe plus puissante est nécessaire. • Se requiere una bomba mayor. Check valve installed backwards. • Montage à l’envers de la soupape d’arrêt • Válvula de retención montada al revés Check flow indicating arrow on check valve body to insure it is installed properly. • Vérifier la fléche indiquant l’écoulement pour s’assurer que la soupape d’arrêt est bien montée. • Inspeccione la flecha indicadora del flujo en el cuerpo de la válvula de retención, para cerciorase de que se encuentre instalada correctamente. Check valve stuck or plugged. • Soupape d’arrêt bloquée ou obstruée. • Válvula de retención atorada u ocluída. Remove check valve and inspect for proper operation. • Démonter et vérifier la soupape d’arrêt pour un bon fonctionnement. • Quite la válvula de retención, y verifique que funcione debidamente. Lift too high for pump. • Aspiration trop puissante pour la pompe. • Altura de impulsión excesiva para la bomba. Check rating table. • Vérifier le tableau d’évaluation. • Estudie la tabla de capacidad. Inlet to impeller plugged. • Arrivée de la roue à aubes obstruée. • Toma de la rueda móvil conectada. Pull pump and clean. • Tirer la pompe pour la nettoyer. • Saque la bomba y límpiela. Pump is air locked. • Présence d’une poche d’air dans la pompe. • La bomba está llena de burbujas de aire. (See corrective action above.) • (Voir ci-dessus la solution.) • (Remítase a la solución anterior.) Lift too high for pump. • Aspiration trop puissante pour la pompe. Check rated pump performance. • Vérifier les caractéristiques • Altura de impulsión excesiva para la bomba. techniques de la pompe. • Verifique el rendimiento normal de la bomba. Pump does not deliver rated capacity. • La pompe ne pompe pas le volume normal. • La bomba no impele a su capacidad normal. Pump cycles continually. • La pompe recommence son cycle sans s’arrêter. • La bomba se enciende y apaga continuamente 8 Low voltage, speed too slow. • Voltage et vitesse pas assez puissants. • Voltaje demasiado bajo, velocidad demasiado baja. Check for proper supply voltage to make certain it corresponds to nameplate voltage. • S’assurer que le voltage correspond bien à celui mentionné sur la plaque. • Verifique que el suministro de electricidad sea adecuado, para cerciorarse de que corresponde al voltaje indicado en la placa del fabricante. Impeller or discharge pipe is clogged. • Obstruction de la roue à aubes ou du tuyau d’écoulement. • La rueda móvil en el tubo de descarga está ocluída. Pull pump and clean. Check pipe for scale or corrosion. • Tirer la pompe pour la nettoyer. Vérifier la présence de dépôts ou de corrosion dans les tuyaux. • Saque la bomba y límpiela. Inspeccione el tubo, en busca de capas de óxido o corrosión. No check valve in long discharge pipe allowing liquid to drain back into sump. • Absence de soupape d’arrêt dans le grand tuyau d’écoulement ainsi permettant l’écoulement du liquide dans le puisard de réception. • Falta la válvula de retención en el tubo de descarga largo, lo cual permite que el líquido refluya a la sumidero. Install a check valve in discharge line. • Installer une soupape d’arrêt sur le tuyau d’écoulement. • Instale una válvula de retención en la tubería de descarga. Check valve leaking. • Fuite à la soupape d’arrêt. • Escape en la válvula de retención. Inspect check valve for correct operation. • Vérifier la soupape d’arrêt pour obtenir un bon fonctionnement. • Verifique que la válvula de retención funcione correctamente. Basin too small for inflow. • Bassin de réception trop petit pour l’afflux. • El fondo del sumidero es muy pequeño o está inundado. Install larger basin. • Installer une bassin de réception plus grand. • Instale un sumidero con un fondo mayor. LIMITED WARRANTY SUMP & EFFLUENT Little Giant ES33 Series Submersible Sump/Effluent Pumps are recommended for use in sumps, basins or lift stations and suitable for pumping basement drainage water, effluent, wastewater and other non-explosive, non-corrosive, non-abrasive liquids not above 140°F with up to 3/8” spherical solids handling ability. (NOT TO BE USED FOR SEWAGE WATER EXCEPT TO PUMP SEPTIC TANK EFFLUENT.) Little Giant products are guaranteed to be in perfect condition when they leave our factory. During the time periods and subject to the conditions hereinafter set forth, LITTLE GIANT, subsidiary of Franklin Electric Company, Inc., will repair or replace to the original user or consumer any portion of your new LITTLE GIANT product which proves defective due to materials or workmanship of LITTLE GIANT. Contact your nearest Authorized Little Giant Service Station for warranty service. At all times LITTLE GIANT shall have and possess the sole right and option to determine whether to repair or replace defective equipment, parts, or components. Damage due to lightning or conditions beyond the control of LITTLE GIANT is NOT COVERED BY THIS WARRANTY. WARRANTY PERIOD PUMPS: 12 months from date of installation or 18 months from date of manufacture, whichever comes first. LABOR, ETC. COSTS: LITTLE GIANT shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or affixing any LITTLE GIANT product, part or component thereof. THIS WARRANTY WILL NOT APPLY: 1. to defects or malfunctions resulting from failure to properly install, operate, or maintain the unit in accordance with printed instructions provided. 2. to failures resulting from abuse, accident or negligence. 3. to normal maintenance services and the parts used in connection with such service. 4. to units which are not installed in accordance with applicable local codes, ordinances and good trade practices. 5. if unit is used for purposes other than for what it was designed and manufactured. 6. if pump exposed to but not limited to the following: sand, gravel, cement, grease, plaster, mud, tar, hydrocarbons, or hydrocarbon derivatives (oil, gasoline, solvents, etc.) or other abrasive or corrosive substances. 7. if pump has been used for continuous pumping of suitable liquids above 140°F. 8. if cord cut off to a length less than three feet. 9. if pump has been dismantled by customer. (Authorized Little Giant Service Stations only can dismantle pump for field service.) RETURN OR REPLACED COMPONENTS: Any item to be replaced under the Warranty must be returned to LITTLE GIANT at Oklahoma City, OK or such other place as LITTLE GIANT may designate, freight prepaid. PRODUCT IMPROVEMENTS: Little Giant reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and/or shipped to such change or improvement. DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, shall not be relied upon by the user, and are not part of the contract for sale. Seller’s and manufacturer’s only obligation, and buyer’s only remedy, shall be the replacement and/or repair by the manufacturer of the product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising out of the use or the inability to use the product, and the user agrees that no other remedy shall be available to it. Before using, the user shall determine the suitability of the product for his intended use, and user assumes all risk of liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an EXCLUSIVE warranty and remedy and is IN LIEU OF any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED, including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow the exclusive or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. In the absence of other suitable proof of the installation date, the effective date of this warranty will be based upon the date of manufacture plus one year. Direct All Notices, etc. To: Service Department, LITTLE GIANT, 301 N. MacArthur Blvd., Oklahoma City, OK 73127-6616. DETERMINATION OF UNIT DATE OF MANUFACTURE: (9-87) month and year stamped on pump and/or serial number on pump nameplate coded to indicate year of manufacture. GARANTIE LIMITÉE POMPE À PUISARD ET À EFFLUENT Les pompes submersibles pour puisard et effluent de Little Giant de série ES33 sont recommandées pour une utilisation dans des puisards, des bassins ou des stations de relèvement et conçues pour le pompage des eaux de drainage d’un sous-sol, des eaux usées, des eaux résiduaires et d’autres liquides non explosifs, non corrosifs et non abrasifs ne dépassant pas 60°C (140°F) et contenant des matières solides sphériques d’un diamètre pouvant aller jusqu’à 5 mm (3/8 po). (NE PAS UTILISER POUR POMPER DES EAUX D’ÉGOUTS, À L’EXCEPTION DES EAUX RÉSIDUAIRES DE FOSSES SEPTIQUES). Little Giant garantit que votre produit est en parfait état au moment de quitter l’usine. Pour la durée et selon les conditions mentionnées dans les présentes, LITTLE GIANT, filiale de Franklin Electric Company, Inc., réparera ou remplacera au profit de l’acheteur ou de l’utilisateur initial toute partie du produit LITTLE GIANT qui, à cause d’un défaut de matériau ou de fabrication, sera défectueuse. Communiquer avec le détaillant LITTLE GIANT le plus près de chez vous pour des réparations sous la garantie. La réparation ou le remplacement de l’appareil, des pièces ou des composantes se fera à la seule discrétion de LITTLE GIANT, et ce en tout temps. Les dommages dûs à la foudre ou à des circonstances hors du contrôle de LITTLE GIANT NE SONT PAS COUVERTS PAR LA PRÉSENTE GARANTIE. DURÉE DE LA GARANTIE POMPES : 12 mois à partir de la date d’installation, ou 18 mois à partir de la date de fabrication, selon le premier terme atteint. FRAIS DE MAIN-D’ŒUVRE, ETC. : EN AUCUN CAS, LITTLE GIANT ne peut être tenue responsable des frais de main-d’œuvre sur place ou de tout autre frais contracté par le client lors de l’enlèvement ou de l’installation (ou des deux) de tout produit ou pièce dudit produit LITTLE GIANT. 9 LA PRÉSENTE GARANTIE NE S’APPLIQUE PAS : 1. aux défauts ou défectuosités résultant d’une installation, d’une utilisation ou d’un entretien non-conforme aux instructions incluses avec le produit; 2. aux défectuosités résultant d’une mauvaise utilisation, d’un accident ou de négligence; 3. à l’entretien normal et aux pièces nécessaires à cet entretien; 4. aux appareils qui n’ont pas été installés conformément aux codes et règlements locaux ainsi qu’aux règles de l’art; 5. à un appareil utilisé dans un but autre que celui dans lequel il fut conçu et fabriqué; 6. à une pompe qui a été exposée, entre autres, aux matières suivantes : sable, gravier, ciment, graisse, plâtre, boue, goudron, hydrocarbones et leurs dérivés (huile, essence, solvants, etc.) ou autres substances abrasives ou corrosives; 7. à une pompe utilisée pour pomper sans interruption des liquides non dangereux à des températures dépassant 140°F; 8. le fil d’alimentation a été coupé à une longueur inférieure à 0,91 m (trois pieds); 9. à une pompe démontée par l’utilisateur. (Seul le détaillant est habilité à démonter la pompe sur place.) RETOUR DE PIÈCES À REMPLACER : Toute pièce qui doit être remplacée conformément à la garantie doit être retournée port payé à l’entreprise LITTLE GIANT à Oklahoma City, Oklahoma U.S.A. ou à tout autre endroit désigné par LITTLE GIANT. AMÉLIORATIONS DE PRODUITS : LITTLE GIANT se réserve le droit de modifier ou d’améliorer ses produits ou toute partie de ces derniers sans être tenue d’apporter ces modifications aux appareils vendus ou expédiés auparavant. DÉNÉGATION : Toute déclaration sur la pompe faite oralement par le vendeur, le fabricant, le représentant ou par toute autre partie ne constitue pas une garantie et, par conséquent, ne peut ni servir à l’utilisateur ni faire partie du contrat de vente. L’unique obligation du vendeur et du fabricant, et l’unique recours de l’acheteur, est le remplacement ou la réparation de la pompe selon les modalités décrites précédemment. Ni le vendeur ni le fabricant ne peuvent être tenus responsables de toute blessure, toute perte ou tout dommage , direct, indirect ou accessoire (incluant, mais non exclusivement, les ventes ou profits perdus, les atteintes aux personnes ou à la propriété ou toute autre perte indirecte ou accessoire) résultant de l’utilisation ou de l’incapacité d’utilisation de la pompe, et l’acheteur convient qu’il ne dispose d’aucun autre recours. Avant d’utiliser la pompe, il incombe à l’acheteur de déterminer si la pompe choisie convient à l’usage anticipé. L’acheteur accepte tout risque relié au choix de la pompe. La garantie et les recours énoncés dans les présentes sont EXCLUSIFS et REMPLACENT toute autre garantie ou recours explicite ou implicite. Tout autre recours ou garantie est donc expressément EXCLU. Cela comprend, mais non exclusivement, toute garantie implicite d’APTITUDE À LA COMMERCIALISATION OU D’APTITUDE PARTICULIÈRE. Certaines juridictions ne permettent pas l’exclusion ou la limitation pour des dommages indirects ou accessoires. Par conséquent, la limitation ou l’exclusion indiquée précédemment peut ne pas être applicable. Cette garantie vous donne des droits particuliers et peut-être d’autres, dépendamment des juridictions en vigueur. S’il n’existe aucune preuve acceptable de la date d’installation, la durée de la présente garantie sera d’un an à partir de la date de fabrication. Adresser toute remarque, etc. à : Service Department, LITTLE GIANT, 301 N. MacArthur, Oklahoma City, OK 73127-6616, U.S.A. 10 DÉTERMINATION DE LA DATE DE FABRICATION : (9-87) Le mois et l’année estampillés sur la pompe ou le numéro de série sur la plaque du fabricant, codé pour indiqué l’année de fabrication. GARANTIA LIMITADA SUMIDERO Y EFLUENTES Las bombas sumergibles para sumidero y efluente serie ES33 de Little Giant se recomiendan para ser utilizadas en sumideros, cubetas o estaciones de levante y se pueden utilizar para agua de drenaje de sótanos, efluentes y aguas residuales y otros líquidos no explosivos o no corrosivos que no estén a más de 60ºC (140ºF) con capacidad de manejo de sólidos esféricos de hasta 9,5 mm (3/8 de pulg.). (NO SE DEBEN UTILIZAR PARA AGUAS CLOACALES, EXCEPTO PARA BOMBEAR EL EFLUENTE DE POZOS SÉPTICOS). Se garantiza que los productos Little Giant están en perfecto estado al salir de fábrica. Durante los lapsos establecidos y sujeto a las estipulaciones que se establezcan de aquí en adelante, la compañía LITTLE GIANT, una subsidiaria de Franklin Electric Company, Inc., reparará o reemplazará para el usuario original o consumidor cualquier porción de su nuevo producto LITTLE GIANT que demuestre estar defectuoso debido a materiales o mano de obra de LITTLE GIANT. Póngase en contacto con su Distribuidor Little Giant para el servicio de garantía. En todo momento, LITTLE GIANT tendrá y poseerá el derecho único y opción para determinar si debe reparar o reemplazar equipo, piezas o componentes defectuosos. Los daños causados por rayos o condiciones fuera del control de LITTLE GIANT NO ESTAN CUBIERTOS POR ESTA GARANTIA. PERIODO DE GARANTIA BOMBAS: 12 meses a partir de la fecha de instalación o 18 meses a partir de la fecha de fabricación, lo que ocurra primero. MANO DE OBRA, ETC. COSTOS: BAJO NINGUNA CIRCUNSTANCIA LITTLE GIANT será responsable o estará expuesto a acción judicial por el costo de mano de obra externa en el lugar u otros cargos incurridos por cualquier cliente al extraer o asegurar cualquier producto LITTLE GIANT, pieza o componente de éste. ESTA GARANTIA NO SERA APLICABLE: 1. a defectos o funcionamiento defectuoso ocasionados por no instalar, operar o mantener la unidad conforme a las instrucciones escritas provistas. 2. a fallas causadas por abuso, accidente o negligencia. 3. a servicios normales de mantenimiento y a las piezas utilizadas para prestar dichos servicios. 4. a unidades que no se hayan instalado de conformidad con los códigos, ordenanzas y buenas prácticas comerciales. 5. a la unidad que es utilizada para fines diferentes de aquellos para los que fue diseñada y fabricada. 6. si la unidad es expuesta, pero sin limitarse, a: arena, grava, cemento, grasa, yeso, barro, brea, hidrocarburos, o derivados de hidrocarburos (aceite, gasolina, solventes, etc.) u otras sustancias abrasivas o corrosivas. 7. si la bomba ha sido utilizada para bombear continuamente líquidos apropiados a temperaturas superiores a 140°F. 8. el cable cortado a menos de tres pies (0,91 m.). 9. si la bomba ha sido desarmada por el cliente. (Sólo el distribuidor puede desarmar la bomba para prestarle servicio externo en el lugar). COMPONENTES QUE DEBEN DEVOLVERSE O REEMPLAZARSE: Cualquier ítem que deba reemplazarse bajo la Garantía debe devolverse, flete prepagado, a LITTLE GIANT en Oklahoma City, OK o a cualquier otro sitio que LITTLE GIANT pueda designar. MEJORAMIENTO DE LOS PRODUCTOS: LITTLE GIANT se reserva el derecho de cambiar o mejorar sus productos o cualquier porción de ellos sin estar obligada a proveer tal cambio o mejora para las unidades vendidas y/o enviadas antes de tal cambio o mejora. RECHAZO: Cualesquiera afirmaciones orales acerca del producto hechas por el vendedor, el fabricante, los representantes o cualesquiera otros, no constituyen garantías, no deberán ser objeto de confianza por parte del usuario, y no son parte del contrato de venta. La única obligación del vendedor y del fabricante, y el único recurso del comprador, será el reemplazo y/o la reparación por el fabricante del producto como se describe arriba. Ni el vendedor ni el fabricante serán responsables por cualquier lesión, pérdida o daños, directos, incidentales o emergentes (incluyendo, pero sin limitarse a daños incidentales, o emergentes por pérdida de ganancias, pérdida de ventas, daños a personas o propiedades, o cualesquiera otra pérdida incidental o emergente), que surja del uso o de la incapacidad de usar el producto y el usuario conviene en que ningún otro recurso estará a su disposición. Antes de utilizar el producto, el usuario deberá determinar la idoneidad de éste para el fin propuesto, y el usuario asume todo riesgo de responsabilidad en relación a dicha utilización. La garantía y recurso descritos en esta garantía limitada es una garantía EXCLUSIVA y el recurso es EN LUGAR DE cualquier otra garantía y recursos explícitos o implícitos, que otras garantías y recursos están expresamente EXCLUIDOS por el presente documento, incluyendo, pero sin limitarse a cualquier garantía implícita de COMERCIABILIDAD o IDONEIDAD PARA UNA FINALIDAD PARTICULAR. Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes, así que la limitación o exclusión arriba indicada puede que no sea aplicable a usted. Esta garantía le da a usted derechos legales específicos, y usted puede tener otros derechos que pueden variar de un estado a otro. En ausencia de otra prueba apropiada de la fecha de instalación, la fecha de vigencia de esta garantía se basará en la fecha de manufactura, más un año. Dirija todas las notificaciones, etc. a: Service Department, LITTLE GIANT, 301 N. MacArthur, Oklahoma City, OK 73127-6616. DETERMINACION DE LA FECHA DE FABRICACION DE LA UNIDAD: (9-87) el mes y el año estampados en la bomba y/o el número serial sobre la placa de la bomba codificado para indicar el año de fabricación. 11 For parts or repair, please contact . . . . . . . . . . . . . . . . . . . . 1.888.572.9933 For technical assistance, please contact . . . . . . . . . . . . . . . 1.888.956.0000 Pour des parties ou la réparation, entrez s’il vous plaît en contact . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933 Pour l’aide technique, entrez s’il vous plaît en contact . . . . 1.888.956.0000 Para partes o la reparación, por favor póngase en contacto . . . . . . . . . . . . . . . . . . . . . . . 1.888.572.9933 Para la ayuda técnica, por favor póngase en contacto . . . . 1.888.956.0000 www.LittleGiantPump.com [email protected] Form 998557 - 01/2008 © 2007 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Little GIANT ES33D1-10 Introduction Manual

Tipo
Introduction Manual

en otros idiomas