iotty OSWFR Glass Electrical Outlet Manual de usuario

Tipo
Manual de usuario
Model: OSWFR
ID: OSW2FR
MOS2FR01
2
Deutsch
Technische Daten 4
Wichtige Hinweise 5
Fehlerbehebung 5
Übersicht über das Gerät 6
Installationsanweisungen 7
App 11
Integrationen 12
Données techniques 13
Notes Importantes 14
Troubleshooting 14
Aperçu du dispositif 15
Instructions de montage 16
Appli 20
Integrations 21
Français
3
Technical specifications 22
Important notes 23
Troubleshooting 23
Device overview 24
Installation steps 25
App 29
Integrations 30
Especificaciones técnicas 31
Notas importantes 32
Resolución de problemas 32
Descripción general del dispositivo 33
Pasos para la instalación 34
Aplicación 38
Integraciones 39
English
Español
4
OFR PLUS Smarte Steckdose
Modell: OSWFR
ID: OSW2FR
Eingang: 230 Vac
Frequenz: 50Hz
Max. 16 A
Umgebungstemperatur: 25°C
Betriebstemperatur: 0°C bis 40°C
Funktioniert nur mit 2.4GHz band
Frequenzbereich: 2412-2472MHz
Maximale HF-Ausgangsleistung des Produkts:
17.29 dBm
Informationen zur HF-Exposition: Die maximal
zulässige Exposition (MPE) wird auf der
Grundlage eines Abstands von d = 20 cm
zwischen dem Gerät und dem menschlichen
Körper berechnet. Um die Einhaltung der HF-
IOTTY srl
Via Del Laghetto, 18/20
33080 Porcia (PN) - ITALY
support@iotty.com
Technische Daten
5
DE
Sicherheitsvorkehrung
Installieren Sie das Gerät in Übereinstimmung mit
allen nationalen und lokalen Vorschriften.
Wenden Sie sich an einen Elektrofachmann, wenn Sie
mit elektrischen Arbeiten nicht vertraut oder nicht
fachkundig sind oder wenn die Verkabelung in Ihrer
Verteilung von den Abbildungen abweicht.
Nur zur Verwendung in Innenräumen und an
trockenen Orten.
Vorsichtsmaßnahme bei der Installation
Neutralleiter erforderlich.
Versuchen Sie im Falle eines Netzwerkfehlers die
folgenden Schritte der Reihe nach:
• Starten Sie das Modem neu und warten Sie ein
paar Minuten, bis alle Geräte verbunden sind
ODER, sollte das Problem fortbestehen:
Expositionsanforderungen zu gewährleisten,
sollte ein Abstand von 20 cm zwischen dem
Gerät und dem Menschen eingehalten werden.
Wichtige Hinweise
Fehlerbehebung
6
• Entfernen Sie die Touch-Glasplatte und drücken Sie
die Reset-Taste am Schalter
ODER, sollte das Problem fortbestehen:
• Entfernen Sie das Glas und drücken Sie
die AP-Taste am Gerät. Wiederholen Sie die
Geräteregistrierung.
mm 60 [in 2,362]
Übersicht über das Gerät
Zum einfachen Ein-
und Ausschalten der
Steckdose muss das
angeschlossene Gerät
nicht ausgesteckt werden.
AN/AUS
Schalter
L N
Mindest-
abstand
zwischen
der Rück-
seite des
iotty-Ge-
räts und
der Wand.
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
Wand
Wand
Wand
Wand
Gewährleistung
Informationen zur Gewährleistung erhalten Sie unter
link.iotty.com/warranty
Reset-Taste
AP-
Taste
Startet das Gerät neu. Alle Einstellungen
bleiben gespeichert.
Macht das WLAN des Geräts
wieder sichtbar. Nützlich für die
Neuregistrierung des Geräts in
der App, die Aktualisierung der
Internet-Zugangsdaten oder
das Ausschalten des WLAN
des Geräts.
Rückseite
des
Geräts
7
Entfernen Sie die alte Steckdose und kennzeichnen
Sie die Drähte. Denken Sie daran, dass Sie den
Nullleiter benötigen, um Steckdose zu installieren.
2
1
Schalten Sie das Schütz der zu ersetzenden
Steckdose aus.
Installationsanweisungen DE
Hauptstromversorgung 230 Vac
= Phase
= Nullleiter
= Erdungskabel
8
Das iotty-Steckdose verdrahten
Führen Sie das Stromversorgungskabel in die
Klemme L ein. Führen Sie den Draht des Nullleiters in
die Klemme N ein. Führen Sie den Draht der Erdung
in die Klemme ein. Vergleichen Sie die Verdrahtung
mit dem Schaltplan in der Abbildung, um zu prüfen,
ob alles korrekt ist.
3Hauptstromversorgung 230 Vac
= Phase oder Leitung
= Nullleiter
= Erdungskabel
L N
L N
L
N
9
4
Drücken Sie alle Drähte in die Wandschalterdose
(verwenden Sie dazu nicht die Rückseite des
Schalters). Setzen Sie iotty-Steckdose in die
Wandschalterdose ein und schrauben Sie sie fest.
Positionieren Sie die Steckdose so, dass sich die AP-
und Reset-Tasten rechts befinden.
Die iotty-Steckdose festschrauben
DE
10
Setzen Sie das Glas so ein, dass sich der kleine Kreis
oben befindet. Befestigen Sie das Glas an Ihrem
iotty-Steckdose
Die Glasplatte anbringen
5
11
Schalten Sie das Schütz der Steckdose ein.
Überprüfen Sie, ob die Verdrahtung korrekt ausgeführt
wurde, indem Sie ein elektrisches Gerät, z. B. ein
Ladegerät, in die Steckdose stecken. Perfekt, jetzt
ist die Installation erfolgreich abgeschlossen und Sie
können mit der Registrierung des Geräts fortfahren.
6App DE
Den Strom wieder einschalten und registriert
das Gerät
12
Hey Google
works with
iotty Geräte sind mit folgenden
kompatibel:
Wenn Sie weitere
Informationen
benötigen, können Sie
uns unter
support@iotty.com
kontaktieren oder
besuchen Sie unseren
FAQ-Bereich
Integrationen
13
OFR PLUS Prise intelligente
Modèle: OSWFR
ID: OSW2FR
Entrée: 230 Vac
Fréquence: 50Hz
Max 16 A
Température ambiante: 25°C
Température de fonctionnement: de 0°C à 40°C
Fonctionne uniquement avec la bande 2.4GHz
Wi-Fi
Gamme de fréquences: 2412-2472MHz
Puissance de sortie RF maximale du produit:
17.29 dBm
Informations sur l’exposition aux RF: Le
niveau d’exposition maximale admissible
(MPE) est calculé sur la base d’une distance
de d = 20 cm entre l’appareil et le corps
IOTTY srl
Via Del Laghetto, 18/20
33080 Porcia (PN) - ITALY
support@iotty.com
Données techniques FR
14
Mesure de sécurité
Faites l’installation conformément à tous les normes
nationales et locales.
Faites venir un électricien professionnel si vous
n’êtes pas familier ou pas à l’aise avec les travaux
électriques, ou si le câblage de votre boîtier
électrique est différent des schémas.
Pour usage intérieur et endroit sec uniquement.
Précaution d’installation
Fil neutre requis.
En cas d’erreur réseau, essayez ces étapes dans
l’ordre:
• Redémarrez votre routeur
OU, if the problem persists,
humain. Pour maintenir la conformité aux
exigences d’exposition aux RF, une distance
de séparation de 20 cm entre l’appareil et
l’humain doit être maintenue.
Notes Importantes
Troubleshooting
15
• Retirez la façade de verre et appuyez sur le bouton
de réinitialisation de la prise
OU, if the problem persists,
• Retirez la façade de verre et appuyez sur le bouton
AP de la prise.
mm 60 [in 2,362]
Aperçu du dispositif
Pour allumer et éteindre
facilement la prise de
courant, pas besoin de
débrancher l’appareil
électroménager.
Bouton
ON/OFF
5 mm
(0.20 in)
Distance
minimum
entre
l’arrière du
dispositif
iotty et le
mur.
L N
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
mur
mur
mur
mur
Garantie
Pour des informations sur la garantie, allez sur link.
iotty.com/warranty
FR
Bouton de redémarrage
Bouton
AP
Redémarrer le dispositif, tous les
paramètres restent enregistrés.
Rend la WiFi du dispositif à
nouveau visible. Utile pour
refaire l’enregistrement du
dispositif sur l’Appli, mettre
à jour les identifiants
pour le réseau Internet
ou éteindre la WiFi de la
plaque.
Arrière du
dispositif
16 Retirez votre ancienne prise et étiquetez les câbles.
2
1
Éteignez le contacteur de la prise que vous
remplacez.
Instructions de montage
17
Insérez le câble du courant dans la borne L. Insérez
le câble du neutre dans la borne N. Insérez le câble
de la terre dans la borne . Confrontez le câblage
avec le schéma électrique de l’image pour vérifier
que tout soit correct.
Câblez la plaque iotty
3Alimentation principale 230 Vac
= Phase ou ligne
= Neutre
= Terre
L N
FR
L N
L
N
18
4
Poussez tous les câbles dans le boîtier mural (ne pas
le faire avec l’arrière de la prise). Insérez la prise iotty
dans le boîtier mural et vissez-le. Placez la prise de
sorte que les boutons AP et reset se trouvent sur la
droite.
Vissez la prise iotty
19
Placez le verre de sorte que le petit cercle soit
positionné en haut.
Fixez le verre
5FR
20
Allumez le contacteur de la prise. Contrôlez que le
câblage ait été correctement réaliséen introduisant
un appareil électrique dans la prise, par exemple un
chargeur. Parfait, l’installation a été réalisée avec
succès et vous pouvez enregistrer le dispositif.
Rébranchez le courant et enregistrer le dispositif
6Appli
21
Hey Google
works with
Les appareils iotty sont compatibles avec les
suivantes:
Si vous avez besoin de
plus d’informations,
vous pouvez nous
contacter à
support@iotty.com
ou visitez notre
Section FAQ
integrations
Rébranchez le courant et enregistrer le dispositif
FR
22
OFR PLUS Smart Outlet
Model: OSWFR
ID: OSW2FR
Input: 230 Vac
Frequency: 50Hz
Max 16 A per RL
Ambient temperature: 25°C
Operating temperature: from 0°C to 40°C
Only works with 2.4GHz Wi-Fi band
Frequency range: 2412-2472MHz
Maximum RF output power of the product:
17.29 dBm
RF exposure information: The Maximum
Permissible Exposure (MPE) level is calculated
based on a distance of d=20 cm between
the device and the human body. To maintain
IOTTY srl
Via Del Laghetto, 18/20
33080 Porcia (PN) - ITALY
support@iotty.com
Technical specifications
23
Safety Precaution
Incorrect installation is dangerous or illegal. Install in
accordance with all national and local codes.
Hire a professional electrician if you are not familiar
or not comfortable with electrical work, or if the
wiring in your electrical box looks different from the
pictures.
For indoor use and dry location only.
Installation Precaution
Neutral wire required.
In case of network error, try these steps in order:
• Restart the router and wait a few minutes to allow
all devices to reconnect
OR, if the problem persists,
• Remove the faceplate and push the Reset button
on the device
compliance with the RF exposure requirement,
a separation distance of 20 cm between the
device and the human should be maintained.
Important notes
Troubleshooting
EN
24
OR, if the problem persists,
• Remove the faceplate and push the AP button on
the device. Repeat device registration
mm 60 [in 2,362]
Device overview
To easily switch on
and off the power of
the outlet no need
of unplugging the
household appliance.
ON-OFF
switch
5 mm
(0.20 in)
minimal
distance
between
the back of
iotty
device and
the wall.
L N
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
wall
wall
wall
wall
Warranty
For warranty information visit us at link.iotty.com/
warranty
Reset button
AP
button
It restarts the device, all settings remain saved.
It makes the iotty
Wi-Fi visible again.
Useful to re-register
the device on the
app, update the Wi-Fi
credentials, or turn off
the device Wi-Fi.
25
Remove your old outlet and label your wires.
Remember that you must have neutral wire.
2
1
Turn off the power at the circuit breaker for the
outlet you are replacing.
Installation steps
EN
26
Insert the power wire into terminal L. Insert the
neutral wire into terminal N. Insert the ground
wire into terminal . Compare the wiring with the
electrical scheme in the picture to be sure everything
is in place.
Wire the iotty plate
3Main power supply 230 Vac
= Power/Live
= Neutral
= Ground
L N
L N
L
N
27
4
Push all the wires back into the wall box (do not push
the wires using the back of the outlet). Insert the
device in the wall box and screw it in. Position the
outlet so that the AP and reset buttons are located
on the right.
Screw the iotty outlet in
EN
28
Attach the faceplate so that the little circle is located
at the top.
Attach the glass faceplate
5
29
Turn on the power at the circuit breaker. Check if the
wiring was made correctly by tapping on the glass
to turn on and off the outlet. Now the installation is
complete and you can proceed to register the device.
Turn on the power and register device
6App
EN
30
Hey Google
works with
iotty devices are compatible with the following
If you need more
information you can
contact us at
support@iotty.com
or visit our
FAQ section
integrations
31
OFR PLUS Enchufe Inteligente
Modelo: OSWFR
ID: OSW2FR
Entrada: 230 Vac
Frecuencia: 50Hz
Máx 16 A
Temperatura ambiente: 25°C
Temperatura de funcionamiento: de 0°C a
40°C
Solo funciona con banda Wi-Fi de 2.4 GHz
Banda de frecuencia: 2412-2472MHz
Potencia máxima de salida de RF del producto:
17.29 dBm
Información sobre la exposición a RF: el nivel
máximo de exposición permitido se calcula
sobre la base de una distancia de 20 cm
entre el dispositivo y el cuerpo humano. Para
IOTTY srl
Via Del Laghetto, 18/20
33080 Porcia (PN) - ITALY
support@iotty.com
Especificaciones técnicas
ES
32
Instrucciones de seguridad
La instalación incorrecta puede llegar a ser peligrosa
o, incluso, ilegal según qué caso IInstalar dentro del
marco legal de todas las leyes nacionales y locales.
Contrata un electricista profesional si no estás
familiarizado o no te sientes cómo manejando
instalaciones eléctricas; o, en caso de que tu
instalación sea diferente a aquella mostrada en las
instrucciones.
Para uso exclusivo dentro del hogar y en lugares poco
húmedos.
Precauciones de Instalación
Se requiere un cable neutro.
En caso de un error con la red, intenta realizar:
• Reinicie el router y espere unos minutos para permitir
que todos los dispositivos se vuelvan a conectar.
garantizar el cumplimiento de la normativa
sobre exposición a RF, debe mantenerse una
distancia de 20 cm entre el dispositivo y el
cuerpo humano.
Notas importantes
Resolución de problemas
33
O, si el problema persiste,
• Retira el cristal y presiona el pulsador de
Restablecimiento del dispositivo
O, si el problema persiste,
• Retira el cristal y presiona el pulsador AP del
dispositivo. Repite el registro del dispositivo.
Garantía
Para más información acerca de la garantía de este
producto, consulte link.iotty.com/warranty ES
mm 60 [in 2,362]
Descripción general del dispositivo
Para encender y apagar
fácilmente el enchufe, no
es necesario desenchufar
el aparato.
Pulsador de
encendido/
apagado
L N
Botón de reinicio
Botón
AP
Reinicia el dispositivo, todas las
configuraciones permanecen guardadas
Hace que iotty Wi-Fi sea de
nuevo visible. Útil para volver a
registrar el dispositivo en la app,
actualizar las credenciales de Wi-
Fi o apagar la Wi-Fi del dispositivo.
5 mm (0.20 in)
distancia mínima
entre la parte
posterior
del
dispositivo
y la caja
eléctrica
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
5 mm • 0.20 in
pared
pared
pared
pared
parte
posterior del
dispositivo
34Retira el viejo enchufe y pon una etiqueta en los cables.
2
1
Apaga el contactor del enchufe que estás
sustituyendo.
Pasos para la instalación
35
Inserta el cable de la corriente en el terminal L.
IInserta el cable de neutro en el terminal N. Inserta
el cable de tierra en el terminal . Compara el
cableado con el diagrama de cableado de la imagen
para comprobar que todo es correcto.
Realiza el cableado de la placa iotty
3Alimentación 230 Vac
= Fase o línea
= Neutro
= Tierra
L N
ES
L N
L
N
36
4
Introduce todos los cables en la caja de pared (no lo
hagas con la parte trasera del enchufe). Introduce el
dispositivo en la caja de pared y atorníllalo. Coloca el
enchufe de forma que los botones AP y de reinicio
queden a la derecha.
Enrosca el enchufe iotty
37
Coloca el cristal de forma que el círculo pequeño se
sitúe en la parte inferior. Fija el cristal.
Coloca el cristal
5
ES
38
Enciende el contactor del enchufe. Comprueba
si el cableado se ha realizado correctamente
conectando un aparato eléctrico al enchufe, por
ejemplo, un cargador. Perfecto, ahora la instalación
se ha realizado correctamente, puedes proceder a
registrar el dispositivo.
Conectar la electricidad y registra el dispositivo
6Aplicación
39
Si necesitas más
información, puedes
ponerte en contacto con
nosotros en
support@iotty.com
o visitar nuestra
sección de preguntas
frecuentes:
Hey Google
works with
ES
Los dispositivos iotty son compatibles con las
siguientes integraciones
40
Hey Google
works with
iotty devices are compatible with the following
If you need more
information you can
contact us at
support@iotty.com
or visit our
FAQ section
integrations
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

iotty OSWFR Glass Electrical Outlet Manual de usuario

Tipo
Manual de usuario