Greenlee CM-660, CM-860, CM-960, CMI-600, CMH-600 Clamp Meter Manual Manual de usuario

Categoría
Medición
Tipo
Manual de usuario

Este manual también es adecuado para

52066382 REV 2 © 2019 Greenlee Tools, Inc. 10/19
Read and understand all of the instructions and safety information in
this manual before operating or servicing this tool.
Lea y entienda todas las instrucciones y la información sobre
seguridad que aparecen en este manual, antes de manejar estas
herramientas o darles mantenimiento.
Lire attentivement et bien comprendre toutes les instructions et
les informations sur la sécurité de ce manuel avant d’utiliser ou de
procéder à l’entretien de cet outil.
Vor Bedienung oder Wartung dieses Messgerätes bitte alle
Anweisungen und Sicherheitsinformationen in diesem Handbuch
genau durchlesen und beachten.
Clamp Meters
Medidores con pinza
Contrôleurs à pince
Zangenmessgeräte
INSTRUCTION MANUAL
MANUAL DE INSTRUCCIONES
MANUEL D’INSTRUCTIONS
BEDIENUNGSANLEITUNG
CM-660
CM-860
CM-960
CMH-600
CMI-600
Español.............23
Français ...........43
Deutsch ............ 63
2
Description
The Greenlee CM-660, CM-860, CM-960, CMH-600, and CMI-600 Clamp Meters are
hand-held testing devices with the following measurement capabilities: AC and DC
voltage, AC current, AC current AmpTip™, frequency, non-contact electric field (EF)
detection, and resistance. They also check diodes and verify continuity. These meters
are designed to be placed on or removed from insulated or uninsulated conductors.
Additional functionality specific to each model includes:
Function CMI-600 CM-960 CMH-600 CM-860
AC + DC Voltage
DC Current AmpTip™
DC + AC Current AmpTip™
DC Current
µDC Current
Temperature (K-style
thermocouple)
Motor Rotation
Phase Rotation
Peak RMS Capture
Capacitance
Backlight
Zero Mode
Other capabilities include:
• Hold Mode to capture the present LCD value
• Record Minimum, Maximum, or Average Mode
• Intelligent Auto Power Off
• Automatic ranging
Safety
Safety is essential in the use and maintenance of Greenlee tools and equipment. This
instruction manual and any markings on the tool provide information for avoiding
hazards and unsafe practices related to the use of this tool. Observe all of the safety
information provided.
Purpose of This Manual
This instruction manual is intended to familiarize all personnel with the safe operation
and maintenance procedures for the Greenlee CM-660, CM-860, CM-960, CMH-600,
and CMI-600 Clamp Meters.
Keep this manual available to all personnel. Replacement manuals are available upon
request at no charge at www.greenlee.com.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
3
SAFETY ALERT SYMBOL
This symbol is used to call your attention to hazards or unsafe practices which
could result in an injury or property damage. The signal word, defined below,
indicates the severity of the hazard. The message after the signal word provides
information for preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result in severe injury or death.
Hazards which, if not avoided, COULD result in severe injury or death.
Hazards or unsafe practices which, if not avoided, MAY result in injury or property
damage.
Read and understand this material before operating or servicing
this equipment. Failure to understand how to safely operate this
tool could result in an accident causing serious injury or death.
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Important Safety Information
Do not discard this product or throw away!
For recycling information, go to www.greenlee.com.
All specifications are nominal and may change as design improvements occur. Greenlee Tools, Inc.
shall not be liable for damages resulting from misapplication or misuse of its products.
® Registered: The color green for electrical test instruments is a registered trademark of
Tools,Innovations Inc.
AmpTip is a trademark of BTC.
KEEP THIS MANUAL
4
Important Safety Information
Electric shock and fire hazard:
• Do not expose this unit to rain or moisture.
• Do not use the unit if it is wet or damaged.
• Clamp meter, test leads or any other clamp accessory, when used to make a mea-
surement, create a System. The System is rated for CAT III 600 V or CAT IV 300V
when using the test leads or accessories provided with the meter. The System CAT
and voltage rating is limited by the lowest rated component in the System when
using test leads or accessories not provided with the meter.
• Inspect the test leads or accessory before use. They must be clean and dry, and
the insulation must be in good condition. Do not use the test lead if the contrasting
inner layer of insulation is visible.
• Use this unit for the manufacturer’s intended purpose only, as described in this
manual. Anyotheruse can impair the protection provided by the unit.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
• Do not apply more than the rated voltage between any two input terminals, or
between any input terminal and earth ground.
• Keep hands and fingers below the barriers on the test leads and the clamp meter
body.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
• Do not operate with the case open.
Before opening the case, remove the test leads from the circuit and shut off the unit.
Failure to observe these warnings could result in severe injury or death.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
5
Important Safety Information
Electric shock hazard:
• Unless measuring voltage, current, or frequency, shut off and lock out power. Make
sure that all capacitors are discharged. Voltage must not be present.
• Set the selector and connect the test leads so that they correspond to the intended
measurement. Incorrect settings or connections can result in incorrect measure-
ments or damage to the unit.
• Using this unit near equipment that generates electromagnetic interference can
result in unstable or inaccurate readings.
Failure to observe these warnings could result in severe injury or death.
Electric shock hazard:
• Do not change the measurement function while the test leads are connected to a
component or circuit.
• Do not clamp the jaw around a conductor carrying a frequency greater than 400Hz.
The magnetic circuitry may reach a hazardous temperature if this frequency is
exceeded.
Failure to observe these precautions may result in injury and can damage the unit.
Electric shock hazard:
• Do not attempt to repair this unit. It contains no user-serviceable parts.
• Do not expose the unit to extremes in temperature or high humidity. Refer to
“Specifications.”
Failure to observe these precautions may result in injury and can damage the unit.
6
Identification
1. Antenna for non-contact EF detection
2. Jaw center indicator for best current accuracy; polarity indicator for DC amps
3. Selects a function or turns power off
4. LCD
5. Input jack for phase and motor rotation functions only
6. Positive input terminal; L2 input for motor and phase rotation
7. Negative, common, or ground input terminal; L1 input for motor and phase rotation
8. Refer to explanation under “Using the Features.”
9. Jaw lever
10. Keep hand or fingers below the dashed line during operation.
11. Jaw
12. Center indicator for AmpTip™ function
Symbols on the Unit
Warning—Read the instruction manual
Warning—Risk of electric shock
Earth ground
Double insulation
AC (alternating current)
DC (direct current)
Application around or removal from hazardous live conductors is permitted.
12
11
1
2
3
4
6
5
9
10
8
7
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
7
Display Icons
1. Automatic ranging is enabled.
2. Record function is enabled.
3. Diode
4. Continuity
5. PEAK-RMS mode is enabled.
6. Phase rotation main supply
7. Motor rotation
8. 8.8.8.8 Numeric display
9. µ Micro (10
-6
)
10. F Farad
11. A Ampere
12. V Volt
13. Hz Hertz (frequency in cycles per second)
14. Ω Ohm
15. k Kilo (10
3
)
16. AmpTip™ function is enabled.
17. Relative zero function is enabled.
18. Polarity indicator
19. VFD AC measurement with filter for accuracy on variable frequency drives
20. AC measurement is selected.
21. + AC + DC measurement is selected.
22. DC measurement is selected.
23. Low battery
24. Hold function is selected.
25. MAX Maximum value being displayed
26. MIN Minimum value being displayed
27. AVG Average value being displayed
6-7
23-27
18
17
22
28
20
19
21
8
9-12
1
16 15 14 13
2 3 4 5
8
Using the Features
All Models
REC: Press momentarily to activate MAX/MIN/AVG recording mode. and “MAX
MIN AVG” appear on the display. The meter beeps when new maximum or minimum
reading is updated. The average reading is calculated over time. Press the button
momentarily to read the MAX, MIN and AVG readings in sequence. Press the button
for 1 second to exit MAX/MIN/AVG recording mode. APO is disabled automatically in
this mode.
SELECT: Press momentarily to toggle between functions, measurement modes,
or display modes. The last used setting becomes the default when that function is
selected again. To change the default, select a new setting. The setting will be stored
in nonvolatile memory.
HOLD: Press momentarily to hold the present value on the display. Press again to exit
this mode.
Intelligent Auto Power Off (APO): The meter automatically turns off after approxi-
mately 32 minutes of inactivity to extend battery life. Active meter function is specified
as: selector switch is rotated or pushbuttons are pressed; readings above 8.5% of
the range; non-OL readings for resistance, continuity, or diode function; non-zero
readings for Hz function; phase rotation segment moving. To wake up the meter from
Auto Power Off, press the SELECT button momentarily and release or turn the rotary
switch OFF and then back on. Always turn the rotary switch to the OFF position when
the meter is not in use.
CM-860, CM-960, CMH-600, and CMI-600 Only
: Press the SELECT button for 1 second to toggle the LCD backlight. The back-
light automatically turns off after 32 seconds to extend battery life.
∆: Press the button for 1 second to toggle between zero and normal mode. In zero
mode the value on the LCD when the button is pressed becomes the offset. As the
input value changes, the offset is subtracted from the actual value. This modified
value is shown on the LCD.
Note: operation when DCA or DC + ACA functions are selected offsets any mag-
netic hysteresis in the jaw. If DCA or DC + ACA reading before measuring is not zero,
press the button for 1 second. The LCD will display “dc_0”. When this clears, the
meter is ready for operation. When measuring more than 5 A, this mode is disabled.
As an indication, the meter will beep three times.
CM-960, CMH-600, and CMI-600 Only
PEAK-RMS: Press the PEAK-RMS button for 1 second to activate PEAK-RMS mode
to capture peak current or voltage in duration as short as 80 ms.
appears on
the display. Press the button for 1 second to exit PEAK-RMS mode. APO is disabled
automatically in this mode.
CMH-600 and CMI-600 Only
and : If desired, press and hold the REC button while turning the meter ON
to enable the Beeper feature. If the segments indicate a clockwise movement, the
beeper sounds a single long beep per segment cycle. If the segments indicate a coun-
terclockwise movement, the beeper sounds three short beeps per segment cycle.
: Ensure the motor is electrically isolated from its power source. Press the
SELECT button momentarily to select Motor function. Connect the meter to the
motor as described in the “Settings Table” section of this manual. From the
perspective of looking down the shaft of the motor, spin it clockwise. If the meter
indicates a clockwise movement, the motor leads connected to L1, L2, and L3 of
the meter are T1, T2, and T3, respectively. If the meter indicates a counterclock-
wise movement, swap any two connects between the meter and motor. Then
retest.
: Press the SELECT button momentarily to select Phase function. Connect the
meter to the phases as described in the “Settings Table” section of this manual.
If the meter indicates a clockwise movement, the phases connected to L1, L2,
and L3 of the meter are L1, L2, and L3, respectively. If the meter indicates a
counterclockwise movement, swap any two connects between the meter and
phases. Then retest.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
9
Using the Test Leads
Electric shock hazard:
The test leads supplied with this product comply with safety standards that limit the
exposed length of the probe tip to 4 mm for measurement categories III and IV. These
test leads include a cap that must be in place when used in measurement category III
or IV applications.
Failure to observe this warning could result in severe injury or death.
Cap must be in place for measurement category III or IV applications.
Cap can be removed for measurement category I or II applications.
10
AC Measurement
AC measurements are usually displayed as RMS (root mean square) values. The RMS
value is equal to the value of a DC waveform, which would deliver the same power if it
replaced the time-varying waveform. Two AC measurement methods are average-re-
sponding RMS calibrated and true RMS-reading.
The average-responding RMS calibrated method takes the average value of the input
signal after full wave rectification, multiplies it by 1.11, and displays the result. This
method is accurate if the input signal is a pure sine wave.
The true RMS-reading method uses internal circuitry to read the true RMS value. This
method is accurate, within the specified crest factor limitations, whether the input signal
is a pure sine wave, square wave, triangle wave, half wave, or signal with harmonics.
The ability to read true RMS provides much more measurement versatility. The Greenlee
CM-660, CM-860, CM-960, CMH-600, and CMI-600 are true RMS meters.
The Waveforms and Crest Factors table shows some typical AC signals and their RMS
values.
Waveforms and Crest Factors
Waveform
RMS Value 100 100 100 100
Average
Value
90 100 87 64
Crest
Factor*
(x)
1.414 1 1.73 2
* The crest factor is the ratio of the peak value to the RMS value; it is represented by
the Greek letter x.
AC + DC True RMS
AC + DC true RMS calculates both of the AC and DC components given by the
expression
when making measurements and responds accurately to the total effective RMS value
regardless of the waveform. Distorted waveforms with the presence of DC components
and harmonics may cause:
• Transformers, generators, and motors to overheat
• Circuit breakers to trip prematurely
• Fuses to blow
• Neutrals to overheat due to the triplen harmonics present on the neutral
• Bus bars and electrical panels to vibrate
CM-960 and CMI-600 can be set to display AC true RMS or AC + DC true RMS.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
11
AC Bandwidth
AC bandwidth is the range of frequencies over which AC measurements can be made
within the specified accuracy. It is the frequency response of the AC functions—not
of the frequency measurement functions. A meter cannot accurately measure the AC
value with frequency spectrums outside its bandwidth. Complex waveforms, noise,
and distorted waveforms contain frequency components that are much higher than the
fundamental; for example, high frequency noise on a 50/60 Hz power line.
Operation
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
Operating Procedure
1. Refer to the “Settings Table.” Set the selector to the proper setting, press SELECT
(when instructed to do so), and connect the test leads to the meter.
2. Refer to “Typical Measurements” for specific measurement instructions.
3. Test the unit on a known functioning circuit or component.
• If the unit does not function as expected on a known functioning circuit, replace
the batteries.
• If the unit still does not function as expected, call Greenlee for technical assis-
tance at 800-435-0786.
4. Take the reading from the circuit or component to be tested.
12
Settings Table
To measure
this value …
Set the
selector
to this
symbol…
These icons
appear on the
display …
Connect
the red
lead to…
Connect
the black
lead to …
ALL MODELS
Voltage (AC)
V
+ COM
Voltage (DC)
V
+ COM
Current, AmpTip™ (AC)
A
N/A N/A
Current (AC)
A
N/A N/A
Continuity
Ω
+ COM
Resistance
Ω
+ COM
Diode
V
+ COM
Frequency
Hz Hz
+ COM
Electric Field (EF)*
EF EF
N/A COM
CM-860, CM-960, CMH-600, and CMI-600 Only
Capacitance**
µF
+ COM
CM-960 and CMI-600 Only
Voltage (AC + DC) + COM
Current, AmpTip™ (DC)
A
N/A N/A
Current, AmpTip™
(AC + DC)
A
N/A N/A
Current (DC)
A
N/A N/A
Current (AC + DC)
A
N/A N/A
CMH-600 and CMI-600 Only
Temperature
Temp C or F
***
Current (µDC)
µA
+ COM
Phase Rotation† + COM
Motor Rotation† + COM
* Use the top side of the stationary jaw, or for more precise measurements use a
probe in the COM terminal.
** Discharge capacitor before measurement. Refer to “Typical Measurements”
regarding polarized capacitors.
*** Thermocouple + connects to +, thermocouple – connects to COM.
Yellow lead connects to L3.
Operation (cont’d)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
13
Typical Measurements and Accuracy
Refer to the “Specifications” section for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at
23 °C ± 5 °C (73.4 °F ± 9 °F).
Frequency must be within the specified bandwidth for non-sinusoidal waveforms.
Crestfactors, unless otherwise specified, are as follows:
• Crest factor < 2.5:1 at full scale
• Crest factor < 5.0:1 at half scale
Frequency
Function Sensitivity (Sine RMS)* Range
600 V 50 V 5.00 Hz ~ 999.9 Hz
60.0 A AmpTip™ 40 A 50.00 Hz ~ 400.0 Hz
60.00 A, 600.0 A 40 A 50.00 Hz ~ 400.0 Hz
* DC bias must be less than 50% of the Sine RMS value.
Accuracy of Frequency Range
Display Range Accuracy
xx.xx ± (1.0% + 0.05 Hz)
xxx.x ± (1.0% + 0.5 Hz)
Voltage Measurement
VHz
EF
VFD
SELECT SELECT
VFD
AC Voltage
Range
Accuracy at
50 Hz to 60 Hz
600.0 ± (1.0% + 0.5 V)
DC Voltage
Range Accuracy
600.0 ± (1.0% + 0.5 V)
AC + DC Voltage
(CM-960, CMI-600 only)
Range
Accuracy at DC,
50 Hz to 60 Hz
600.0 ± (1.2% + 0.7 V)
Input Impedance: 10 MΩ, 100 pF nominal
14
Current Measurement
Typical Measurements and Accuracy (cont’d)
Flame Sensor
Control
Board
Pilot Flame
µA
AmpTip™ Function
µA DC Current
μDC Current (CMH-600 and CMI-600 only)
Range Accuracy Burden Voltage
200.0 μA ± (1.0% + 0.5 μA)
3.5 mV/μA
2000 μA ± (1.0% + 5 μA)
A
Hz
AmpTip™ AC Current
Range Accuracy Range
Accuracy at
50 Hz to 60 Hz**
60.00 A
< 0.20 A* unspecified
0.00 A to 3.99 A ± (1.5% + 0.15 A)
4.00 A to 60.00 A ± (1.5% + 0.05 A)
* For CM-660, CM-860, and CMH-600 only.
** For CM-960 and CMI-600 only, induced error for
adjacent current carrying conductors is < 0.01 A/A.
AmpTip™ DC Current (CM-960 and CMI-600 only)
Range Accuracy Range Accuracy†
60.00 A
0.00 A to 3.99 A ± (2.0% + 0.15 A)
4.00 A to 60.00 A ± (2.0% + 0.05 A)
AmpTip™ DC + AC Current
(CM-960 and CMI-600 only)
Range
Accuracy
Range
Accuracy at DC,
50 Hz to 60 Hz†
60.00 A
0.00 A to 3.99 A ± (2.0% + 0.17 A)
4.00 A to 60.00 A ± (2.0% + 0.07 A)
† Induced error for adjacent current carrying conductors is < 0.01 A/A.
Note: Use Δ if there is an offset before the measurement is taken.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
15
Typical Measurements and Accuracy (cont’d)
Current Measurement
(cont’d)
AC and DC Clamp
A
Hz
AC Current (CM-960 and CMI-600 only)
Range Accuracy Range
Accuracy at
50 Hz to 100 Hz*†
Accuracy at
100 Hz to 400 Hz*†
60.00 A
0.00 A to 8.99 A ± (1.8% + 0.15 A) ± (2.0% + 0.15 A)
9.00 A to 60.00 A ± (1.8% + 0.05 A) ± (2.0% + 0.05 A)
600.0 A 60.0 A to 600.0 A ± (1.8% + 0.5 A) ± (2.0% + 0.5 A)
* Maximum crest factor < 2:1 at full scale and < 4:1 at half scale.
AC Current (CM-660, CM-860, and CMH-600 only)
Range Accuracy Range
Accuracy at
50 Hz to 100 Hz*†
Accuracy at
100 Hz to 400 Hz*†
60.00 A
0.00 A to 0.19 A unspecified unspecified
0.20 A to 5.99 A ± (1.8% + 0.15 A) ± (2.0% + 0.15 A)
6.00 A to 60.00 A ± (1.8% + 0.05 A) ± (2.0% + 0.05 A)
600.0 A 60.0 A to 600.0 A ± (1.8% + 0.5 A) ± (2.0% + 0.5 A)
* For any measurement, when the conductor is not positioned on the center of the
jaws, add 2.0% to the accuracy for position error.
DC Current (CM-960 and CMI-600 only)
Range Accuracy Range Accuracy†
60.00 A
0.00 A to 8.99 A ± (2.0% + 0.15 A)
9.00 A to 60.00 A ± (2.0% + 0.05 A)
600.0 A 60.0 A to 600.0 A ± (2.0% + 0.5 A)
AC + DC Current (CM-960 and CMI-600 only)
Range Accuracy Range
Accuracy at
50 Hz to 100 Hz†
Accuracy at
100 Hz to 400 Hz†
60.00 A
0.00 A to 8.99 A ± (2.2% + 0.15 A) ± (2.7% + 0.17 A)
9.00 A to 60.00 A ± (2.2% + 0.05 A) ± (2.7% + 0.07 A)
600.0 A 60.0 A to 600.0 A ± (2.2% + 0.5 A) ± (2.7% + 0.7 A)
† Induced error for adjacent current carrying conductors is < 0.01 A/A.
Note: Use Δ if there is an offset before the measurement is taken.
16
Typical Measurements and Accuracy (cont’d)
Ω
SELECT
Resistance
Measurement
SELECT
Continuity Check
Resistance
Range Accuracy
600.0 Ω ± (1.0% + 0.5 Ω)
6.000 kΩ ± (1.0% + 0.005 kΩ)
60.00 kΩ ± (1.0% + 0.05 kΩ)
Open Circuit Voltage: 1.0 VDC
Continuity
Tone Threshold: Between 10 Ω and 250 Ω
Response Time: Approximately 32 ms
Capacitance
Measurement
Capacitance (CM-860, CM-960,
CMH-600, and CMI-600 only)
Range Accuracy*
200.0 μF ± (2.0% + 0.4 μF)
2500 μF ± (2.0% + 4 μF)
* For film capacitors (capacitors with
negligible dielectric absorption).
Note: For polarized capacitors, attach red
probe to positive terminal and black probe to
negative terminal of capacitor.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
17
Typical Measurements and Accuracy (cont’d)
Reverse Bias
Forward Bias
SELECT
Diode Measurement
Diode Test
Measuring Range: 2.000 V
Accuracy: ± (1.5% + 0.005 V)
Test Current (typical): 0.3 mA
Open Circuit Voltage (typical):
< 3.5 VDC
Temperature
SELECT
Temperature (CMH-600 and CMI-600)
Range Accuracy*
-40.0 °C ~ 99.9 °C ± (1.0% + 0.8 °C)
100 °C ~ 400 °C ± (1.0% + 1 °C)
-40.0 °F ~ 211.8 °F ± (1.0% + 1.5 °F)
212 °F ~ 752 °F ± (1.0% + 2 °F)
* K-type thermocouple accuracy not included.
Thermocouple supplied with meter meets
standard JIS C 1602-1981.
18
Typical Measurements and Accuracy (cont’d)
A
10 mm
(0.4")
B
SELECT
Electric Field
Note: CM-660
and CM-860
have a dedicated
switch position.
A–Non-contact OR
B–Contact, precision measurement
Non-contact EF Detection
Typical
Voltage
Range at
50 Hz to 60 Hz
LCD
Indication
20 V 10 V ~ 36 V -
55 V 23 V ~ 83 V - -
110 V 59 V ~ 165 V - - -
220 V 124 V ~ 330 V - - - -
440 V 250 V ~ 600 V - - - - -
Phase Rotation Motor Rotation
Clockwise Counterclockwise
SELECT
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
19
Specifications
Display: LCD, 3-5/6 digits 6000 counts
Polarity: Automatic
Update Rate: 5 per second nominal
Operating Conditions:
0 °C to 31 °C (32 °F to 88 °F), relative humidity 0% to 80%
31 °C to 40 °C (88 °F to 104 °F), relative humidity decreasing linearly
from 80% to 50%
Pollution Degree: 2
Indoor use only
Altitude: Operating below 2000 m (6500 ft)
Storage Temperature: -20 °C to 60 °C, relative humidity < 80%, with batteries removed
Temperature Coefficient: Nominal 0.15 x (Accuracy) per °C below 18 °C from 0 °C to
18 °C (32 °F to 64.4 °F) and above 28 °C from 28 °C to 40 °C (82.4 °F to 104 °F) or
otherwise specified
Sensing: True RMS
E.M.C.:
Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8,
EN61000-4-11)
In an RF field of 1 V/m at a frequency of 405 MHz, DCA and DC+AC A mode
(CM-960 and CMI-960): Total Accuracy = Specified Accuracy + 20 digits
In an RF field of 1 V/m resistance mode (all models) and DC µA mode
(CMH-600 and CMI-600): Total Accuracy = Specified Accuracy + 25 digits
In an RF field of 3 V/m, all other modes and models not specified above:
Total Accuracy = Specified Accuracy + 20 digits
Safety: Double insulation per UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed. 1,
CAN/CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 2 and
IEC/EN61010-031 Ed. 1.1 to CAT III 600V and CAT IV 300V AC and DC
Overload Protections:
Jaws:
Current with Frequency Function: 600 A DC/AC RMS at ≤ 400 Hz
Terminals:
Voltage and Phase Rotation Function: 660 V DC/920 V AC RMS
All Other Modes and Functions: 600 V DC/AC RMS
Transient Protection: 6.0 kV (1.2/50 μs surge)
Power Supply: Two 1.5 V AAA batteries (NEDA 24A or IEC LR03)
Low Battery:
Capacitance and Frequency Function: Approximately 2.85 V
All Other Functions: Approximately 2.5 V
Current Consumption:
CM-960 and CMI-600: Typically 13 mA
CM-660, CM-860, and CMH-600: Typically 4.3 mA
APO Timing: Idle for 32 minutes
APO Consumption: 5 μA typical
Dimensions:
CM-960 and CMI-600: 222 mm x 76 mm x 37 mm (8.7" x 3.0" x 1.4")
CM-660, CM-860, and CMH-600: 217 mm x 76 mm x 37 mm (8.5" x 3.0" x 1.4")
Jaw Opening and Conductor Diameter: 30 mm max (1.18")
20
Measurement Categories
These definitions were derived from the international safety standard for insula-
tion coordination as it applies to measurement, control, and laboratory equipment.
These measurement categories are explained in more detail by the International
Electrotechnical Commission; refer to either of their publications: IEC 61010-1 or
IEC60664.
Measurement Category II
Local level. Appliances, portable equipment, and the circuits they are plugged into.
Some examples include light fixtures, televisions, and long branch circuits.
Measurement Category III
Distribution level. Permanently installed machines and the circuits they are hard-wired
to. Some examples include conveyor systems and the main circuit breaker panels of a
building’s electrical system.
Measurement Category IV
Primary supply level. Overhead lines and other cable systems. Some examples include
cables, meters, transformers, and other exterior equipment owned by the power utility.
Statement of Conformity
Greenlee Tools, Inc. is certified in accordance with ISO 9001 (2000) for our Quality
Management Systems.
The instrument enclosed has been checked and/or calibrated using equipment that is
traceable to the National Institute for Standards and Technology (NIST).
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
21
Maintenance
Electric shock hazard:
Before opening the case, remove the test leads from the circuit and shut off the unit.
Failure to observe this warning could result in severe injury or death.
Replacing the Batteries
1. Disconnect the unit from the
circuit. Turn the unit OFF.
2. Remove the two screws from
the battery access door and
remove it.
3. Replace the batteries, making
sure to observe the polarity.
Cleaning and Storage
Periodically wipe the case with a
damp cloth and mild detergent; do
not use abrasives or solvents.
If the meter will not be used for
periods longer than 60 days,
remove the batteries and store
them separately.
22
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
23
Descripción
Los medidores con pinza CM-660, CM-860, CM-960, CMH-600 y CMI-600 de Greenlee
son unidades de prueba que caben perfectamente en la palma de la mano, capaces
de efectuar los siguientes tipos de mediciones: Voltaje de CA y CC, corriente de CA,
AmpTip™ para corriente de CA, frecuencia, detección de campos eléctricos (EF)
sin contacto y resistencia. También sirven para verificar diodos y continuidad. Estos
medidores están diseñados para ser colocados en o retirados de conductores con
aislamiento o sin aislamiento.
Entre las funciones adicionales específicas para cada modelo se incluyen:
Función CMI-600 CM-960 CMH-600 CM-860
Voltaje de CA + CC
AmpTip™ para corriente de CC
AmpTip™ para corriente de
CC + CA
Corriente de CC
Corriente de µCC
Temperatura (termopar estilo K)
Rotación del motor
Rotación de fase
Captura de RMS máximo
Capacitancia
Luz de fondo
Modo Cero
Entre otras funciones se incluyen:
• Modo de Retención para capturar el valor de LCD presente
• Modo de Registro mínimo, máximo o promedio
• Apagado automático inteligente
• Escala automática
Acerca de la seguridad
Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las
herramientas y equipo Greenlee. Este manual de instrucciones y todas las marcas que
ostenta la herramienta le ofrecen la información necesaria para evitar riesgos y hábitos
poco seguros relacionados con su uso. Siga toda la información sobre seguridad que se
proporciona.
Propósito de este manual
Este manual de instrucciones tiene como propósito familiarizar a todo el personal con
los procedimientos de operación y mantenimiento seguros para los medidores con
pinzas CM-660, CM-860, CM-960, CMH-600, y CMI-600 de Greenlee.
Manténgalo siempre al alcance de todo el personal. Puede obtener copias adicionales
de manera gratuita, previa solicitud en www.greenlee.com.
24
SÍMBOLO DE ALERTA
SOBRE SEGURIDAD
Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría
ocasionar lesiones o daños materiales. Cada uno de los siguientes términos denota
la gravedad del riesgo. El mensaje que sigue a dichos términos le indica cómo
puede evitar o prevenir ese riesgo.
Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso
la muerte.
Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la
muerte.
Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o
daños materiales.
Lea y entienda este documento antes de manejar esta
herramienta o darle mantenimiento. Utilizarla sin comprender
cómo manejarla de manera segura podría ocasionar un
accidente, y como resultado de éste, graves lesiones o incluso la
muerte.
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar graves
lesiones o incluso la muerte.
Importante Información sobre Seguridad
¡No deseche ni descarte este producto!
Para información sobre reciclaje, visite www.greenlee.com.
Todas las especificaciones son nominales y pueden cambiar conforme tengan lugar mejoras de
diseño. Greenlee Tools, Inc. no se hace responsable de los daños que puedan surgir de la mala
aplicación o mal uso de sus productos.
® Registrado: El color verde para instrumentos de verificación eléctricos es una marca registrada
de Tools, Innovations Inc.
Amp-Tip es una marca comercial de BTC.
CONSERVE ESTE MANUAL
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
25
Importante Información sobre Seguridad
Peligro de electrocución e incendio:
• No exponga esta unidad ni a la lluvia ni a la humedad.
• No utilice esta unidad si se encuentra mojada o dañada.
• Los medidores con pinza, las puntas de prueba o cualquier otro accesorio de
cierre, cuando se utilizan para tomar una medición, crean un sistema. El sistema
tiene capacidad nominal CAT III 600 V o CAT IV 300 V cuando se utilizan los cables
de prueba o los accesorios suministrados con el medidor. El sistema CAT y la
capacidad nominal de voltaje están limitados por el componente con capacidad
mínima en el sistema cuando se utilizan cables de prueba o accesorios no
suministrados con el medidor.
• Revise minuciosamente los cables de prueba o el accesorio, antes de utilizarlos.
Deberán estar limpios y secos, y su forro aislante deberá estar en buenas
condiciones. No use el cable de prueba si está visible la capa de aislamiento interior
de contraste.
• Utilícela únicamente para el propósito para el que ha sido diseñada por el
fabricante,
tal como se describe en este manual. Cualquier otro uso puede menoscabar la
protección proporcionada por la unidad.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la
muerte.
Peligro de electrocución:
• No aplique más del voltaje nominal entre dos terminales de entrada cualesquiera, o
entre una terminal de entrada cualquiera y una conexión a tierra.
• Mantenga las manos y los dedos por debajo de las barreras en los cables de prueba
y en el cuerpo del medidor con pinza.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la
muerte.
Peligro de electrocución:
• No haga funcionar esta unidad con la caja abierta.
• Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la
muerte.
26
Importante Información sobre Seguridad
Peligro de electrocución:
• A menos que vaya a medir tensión, corriente o frecuencia, apague y bloquee la
energía. Asegúrese de que todos los condensadores estén totalmente sin carga. No
debe haber tensión alguna.
• Coloque el interruptor de selección y conecte los cables de prueba de modo que
correspondan al tipo de medición que se desea efectuar. Los ajustes o conexiones
incorrectos pueden resultar en mediciones incorrectas o daños en la unidad.
• Al utilizar esta unidad cerca de equipo que genere interferencia electromagnética
quizá se obtenga una lectura inexacta e inestable.
De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la
muerte.
Peligro de electrocución:
• No cambie la función de medición mientras los cables de prueba estén conectados
a un componente o circuito.
• No coloque la mordaza de la abrazadera alrededor de un conductor que porte
una frecuencia mayor de 400 Hz. Los circuitos magnéticos podrían alcanzar una
temperatura peligrosa si se excede esta frecuencia.
De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad.
Peligro de electrocución:
• No intente reparar esta unidad, ya que contiene partes que deben recibir
mantenimiento por parte de un profesional.
• No exponga la unidad a ambientes de temperatura extrema o altos niveles de
humedad. Consulte las Especificaciones.
De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
27
Identificación
1. Antena para detección de EF sin contacto
2. Indicador central en la mordaza para mejor precisión de corriente;
indicador de polaridad para amperios de CC
3. Selecciona una función o apaga la unidad
4. LCD
5. Conector de entrada para las funciones de rotación de motor y fase únicamente
6. Terminal de entrada positiva; entrada L2 para rotación de motor y fase
7. Terminal de entrada negativo, común o conexión a tierra; entrada L1 para rotación
de motor y fase
8. Consulte la explicación pertinente en la sección “Cómo utilizar
las distintas funciones”
9. Palanca de mordaza
10. Mantenga la mano o los dedos por debajo de la línea de puntos durante la
operación.
11. Mordaza
12. Indicador de centro para la función AmpTip™
12
11
1
2
3
4
6
5
9
10
8
7
Símbolos en la unidad
Advertencia — Lea el manual de instrucciones
Advertencia — Peligro de electrocución
Conexión a tierra
Doble forro aislante
CA (corriente alterna)
CC (corriente continua)
Se permite la aplicación o el retiro de la unidad alrededor de conductores
energizados peligrosos.
28
Iconos de la pantalla
1. Está habilitada la selección automática de escala.
2. Está habilitada la función Record (Grabar).
3. Diodo
4. Continuidad
5. Está habilitado el modo PEAK-RMS.
6. Suministro principal de rotación de fase
7. Rotación del motor
8. 8.8.8.8 Pantalla numérica
9. µ Micro (10
-6
)
10. F Faradio
11. A Amperio
12. V Voltio
13. Hz Hertzios (frecuencia en ciclos por segundo)
14. Ω Ohmios
15. k Kilo (10
3
)
16. AEstá habilitada la función AmpTip™.
17. Está habilitada la función Cero relativo (Relative zero).
18. Indicador de polaridad
19. VFD Medición de CA con filtro para precisión en variadores de frecuencia
20. Está seleccionada la medición de CA.
21. + Está seleccionada la medición de CA + CC.
22. Está seleccionada la medición de CC.
23. Batería baja
24. Está seleccionada la función Hold (Retención de datos en pantalla).
25. MAX Aparece el valor máximo
26. MIN Aparece el valor mínimo
27. AVG Aparece el valor promedio
6-7
23-27
18
17
22
28
20
19
21
8
9-12
1
16 15 14 13
2 3 4 5
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
29
Cómo utilizar las distintas funciones
Todos los modelos
REC: Oprima momentáneamente este botón para activar el modo de grabación
MAX/MIN/AVG. y “MAX MIN AVG” aparecerán en la pantalla. El medidor emite
un tono audible siempre que se actualice la lectura de valor máximo o mínimo. La
lectura promedio se calcula en el transcurso del tiempo. Oprima momentáneamente
el botón para leer en secuencia los valores MAX, MIN y AVG. Oprima el botón durante
1 segundo para salir del modo de grabación MAX/MIN/AVG. En este modo APO se
inhabilita automáticamente.
SELECT: Oprímalo momentáneamente para alternar entre las funciones, modos de
medición o modos de pantalla. El último ajuste utilizado se convierte en el valor por
defecto cuando se vuelva a seleccionar dicha función. Para cambiar el valor por
defecto, seleccione un nuevo ajuste. El ajuste será almacenado en una memoria
estable.
HOLD: Oprima momentáneamente para retener en pantalla el valor actual. Oprímalo
nuevamente para salir de este modo.
Apagado automático inteligente (APO): El medidor se apaga automáticamente
después de aproximadamente 32 segundos de inactividad a fin de preservar la
vida útil de la batería. La función activa del medidor se especifica como: Se gira el
interruptor selector o se presionan los botones pulsadores; las lecturas por encima
de 8.5% de la escala; lecturas de no OL para resistencia, continuidad, o función de
diodos, lecturas diferentes de cero para la función HZ; rotación de fase de segmentos
en movimiento. Para activar el medidor desde el apagado automático APO, oprima
momentáneamente el botón SELECT y suéltelo o gire el interruptor rotativo a la
posición OFF y después de regreso a la posición de encendido ON. Siempre gire el
interruptor rotativo a la posición OFF cuando el medidor no esté en uso.
CM-860, CM-960, CMH-600, y CMI-600 solamente
: Oprima el botón SELECT durante 1 segundo para alternar la luz de fondo de la
pantalla LCD. La luz de fondo se apagará automáticamente después de 32 segundos
para prolongar la vida útil de la batería.
∆: Oprima el botón durante 1 segundo para alternar entre cero y modo normal. En
el modo cero el valor en la pantalla LCD cuando se oprime el botón se convierte en la
desviación. A medida que cambia el valor de entrada, se resta la desviación del valor
actual. Este valor modificado se muestra en la pantalla LCD.
Nota: La operación cuando se seleccionan las funciones DCA o CC + CAA compensa
cualquier histéresis magnética en la mordaza. Si la lectura de DCA o CC + CAA antes
de la medición no es cero, entonces oprima el botón durante 1 segundo. En la
pantalla LCD aparecerá “dc_0”. Cuando este valor desaparezca, el medidor estará
listo para la operación. Cuando la lectura de medición sea mayor de 5 A, se inhabilita
este modo. A manera de indicación el medidor emitirá tres pitidos.
CM-960, CMH-600, y CMI-600 solamente
PEAK-RMS (Máximo valor eficaz [RMS]): Oprima el botón PEAK-RMS durante
1segundo para activar el modo PEAK-RMS y capturar la corriente pico o voltaje con
duraciones de tan solo 80 ms. Aparece el en la pantalla. Oprima el botón
durante 1 segundo para salir del modo PEAK-RMS. En este modo APO se inhabilita
automáticamente.
30
Cómo utilizar las distintas funciones (continuación)
CMH-600 y CMI-600 solamente
y : Si se desea, oprima sin soltar el botón REC a la vez que enciende el
medidor para habilitar la función Beeper (Señal audible). Si los segmentos indican
un movimiento hacia la derecha, la señal audible emitirá un solo pitido prolongado
por ciclo de segmento. Si los segmentos indican un movimiento hacia la izquierda, la
señal audible emitirá tres pitidos cortos por ciclo de segmento.
: Asegúrese que el motor esté eléctricamente aislado de su fuente de
alimentación. Oprima el botón SELECT momentáneamente para seleccionar
la función Motor. Conecte el medidor al motor según se describe en la sección
“Tabla de ajustes” en este manual. Desde la perspectiva de arriba hacia abajo,
gire el eje del motor hacia la derecha. Si el medidor indica un movimiento hacia
la derecha, los cables de prueba del motor conectados a L1, L2 y L3 del medidor
son T1, T2 y T3, respectivamente. Si el medidor indica un movimiento hacia la
izquierda, intercambie cualesquiera dos conexiones entre el medidor y el motor.
Después repita la prueba.
: Oprima el botón SELECT momentáneamente para seleccionar la función
Fase. Conecte el medidor a las fases según se describe en la sección “Tabla de
ajustes” en este manual. Si el medidor indica un movimiento hacia la derecha, las
fases conectadas a L1, L2 y L3 del medidor son L1, L2 y L3, respectivamente. Si
el medidor indica un movimiento hacia la izquierda, intercambie cualesquiera dos
conexiones entre el medidor y las fases. Después repita la prueba.
Cómo utilizar los cables de prueba
Peligro de descarga eléctrica:
Los cables de prueba suministrados con este producto cumplen con las normativas
de seguridad que limitan la longitud expuesta de la punta de la sonda a 4 mm para
mediciones en las categorías III y IV. Estos cables de prueba incluyen una tapadera
que debe estar colocada en posición cuando se utilizan en aplicaciones con categoría
de medición III o IV.
De no observarse esta advertencia podrían sufrirse lesiones graves o incluso la
muerte.
La tapadera debe estar en posición para aplicaciones
con categoría de medición III o IV.
Se puede retirar la tapadera para aplicaciones
con categoría de medición I o II.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
31
Medición de corriente alterna
Las mediciones de corriente alterna generalmente se muestran como valores eficaces
(RMS o root mean squared). El valor eficaz equivale al valor de una forma de onda de
CC, la cual brinda la misma potencia que si reemplazara la forma de onda variable
con el tiempo. Existen dos métodos de medición de corriente alterna: calibrados para
responder al valor eficaz medio y a una lectura de valores eficaces reales.
El método calibrado para responder al valor eficaz medio toma el valor medio de
la señal de entrada luego de una rectificación total de onda, la multiplica por 1,11
y muestra el resultado. El resultado es exacto si la señal de entrada es una onda
sinusoidal pura.
El método de lectura de valores eficaces reales utiliza un circuito interno para leer
el valor eficaz real. Este método es exacto, dentro de las limitaciones de factor de
cresta especificadas, independientemente del tipo de señal de entrada, ya sea una
onda sinusoidal pura, rectangular, triangular, media onda o señal con armónicas. La
capacidad para leer valores eficaces reales brinda una mayor versatilidad de medición.
Los modelos CM-660, CM-860, CM-960, CMH-600, y CMI-600 de Greenlee son
medidores de RMS reales.
La tabla de Formas de onda y Factores de cresta muestra algunas de las señales de CA
y sus valores eficaces reales más comunes.
Formas de onda y Factores de cresta
Forma de
onda
Valor eficaz 100 100 100 100
Valor medio 90 100 87 64
Factor de
cresta*
(x)
1,414 1 1,73 2
* El factor de cresta es el cociente de un valor máximo en relación con el valor
eficaz; está representado por la letra griega x.
Valor eficaz real CA + CC
El valor eficaz real CA + CC calcula los componentes de CA y CC expresados
al efectuar mediciones y responde acertadamente al valor eficaz efectivo total
independientemente de la forma de onda. Formas de onda distorsionadas con la
presencia de componentes de CC y armónicas podrían ocasionar:
• el sobrecalentamiento de transformadores, generadores y motores
• el disparo prematuro de interruptores automáticos de circuito
• que fusibles se quemen
• el sobrecalentamiento de neutrales debido a la presencia de armónicas triples en el
neutral
• la vibración de barras colectoras y paneles eléctricos
Los modelos CM-960 y CMI-600 pueden configurarse para mostrar RMS reales de CA o
RMS reales de CA + CC.
32
Ancho de banda de CA
El ancho de banda de CA es la escala de frecuencias sobre la cual se puede realizar
mediciones de CA dentro de las tolerancias de precisión especificadas. Se trata de la
respuesta de frecuencia de las funciones de CA—no de las funciones de medición de
frecuencia. Un medidor no puede medir con precisión los valores de CA si los espectros
de frecuencia están fuera de su ancho de banda. Las formas de onda complejas, el
ruido y las formas de onda distorsionadas contienen componentes de frecuencia mucho
mayores que los fundamentales; por ejemplo, ruido de alta frecuencia en una línea de
energía de 50/60 Hz.
Operación
Peligro de electrocución:
El contacto con circuitos activados podría ocasionar graves
lesiones o incluso la muerte.
Procedimiento de operación
1. Consulte la Tabla de ajustes. Coloque el interruptor de selección en el ajuste
apropiado, oprima SELECT (cuando se le pida que lo haga), y conecte los cables de
prueba al multímetro.
2. Consulte la sección “Mediciones más comunes” en relación con las instrucciones
específicas para cada tipo de medición.
3. Pruebe la unidad en un circuito o componente que se sabe está funcionando
perfectamente.
• Si la unidad no funciona como debería en un circuito que se sabe está
funcionando perfectamente, reemplace las baterías.
• Si la unidad aún sigue sin funcionar como debería, llame a Greenlee al 800-435-
0786 para obtener asistencia técnica.
4. Anote la lectura del circuito o componente que se está verificando.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
33
Tabla de ajustes
Para medir este valor …
Coloque el
interruptor
de selección
en este
símbolo…
Enseguida
aparecen
estos
iconos en la
pantalla…
Conecte
el cable
de prueba
rojo a…
Conecte
el cable
de prueba
negro a …
TODOS LOS MODELOS
Voltaje (CA)
V
+ COM
Voltaje (CC)
V
+ COM
Corriente, AmpTip™ (CA)
A
N/A N/A
Corriente alterna (CA)
A
N/A N/A
Continuidad
Ω
+ COM
Resistencia
Ω
+ COM
Diodo
V
+ COM
Frecuencia
Hz Hz
+ COM
Campo eléctrico (EF)*
EF EF
N/A COM
CM-860, CM-960, CMH-600, y CMI-600 solamente
Capacitancia**
µF
+ COM
CM-960 y CMI-600 solamente
Voltaje (CA + CC) + COM
Corriente, AmpTip™ (CC)
A
N/A N/A
Corriente, AmpTip™
(CA + CC)
A
N/A N/A
Corriente (CC)
A
N/A N/A
Corriente (CA + CC)
A
N/A N/A
CMH-600 y CMI-600 solamente
Temperatura
Temp C or F
***
Corriente (µCC)
µA
+ COM
Rotación de fase† + COM
Rotación del motor† + COM
* Use el lado superior de la mordaza estacionaria, o para mediciones de mayor
precisión use una sonda en el terminal COM.
** Descargue el condensador antes de efectuar una medición. Consulte “Mediciones
típicas” respecto a los capacitores polarizados.
*** Termopar + conexiones a +, termopar – conexiones a COM.
El cable amarillo se conecta a L3.
Operación (continuación)
34
Mediciones típicas y precisión
Consulte la sección “Especificaciones” en relación con las condiciones de operación y
el coeficiente de temperatura.
La precisión se especifica de la siguiente manera: ± (un porcentaje de la lectura + una
cantidad fija) a 23°C ± 5 °C (73,4 °F ± 9 °F).
La frecuencia debe hallarse dentro del ancho de banda especificado para formas de
onda no sinusoidales. Los factores de cresta, salvo que se especifique de manera
diferente, son de la manera siguiente:
• Factor de cresta < 2,5:1 a plena escala
• Factor de cresta < 5,0:1 a escala media
Frecuencia
Función
Sensibilidad
(sinusoidalRMS)*
Escala
600 V 50 V 5,00 Hz ~ 999,9 Hz
60,0 A AmpTip™ 40 A 50,00 Hz ~ 400,0 Hz
60,00 A, 600,0 A 40 A 50,00 Hz ~ 400,0 Hz
* La desviación de CC debe ser menor que el 50% del valor sinusoidal RMS.
Precisión de la escala de frecuencias
Escala de la pantalla Precisión
xx.xx ± (1,0% + 0,05 Hz)
xxx.x ± (1,0% + 0,5 Hz)
Medición de voltaje
VHz
EF
VFD
SELECT SELECT
VFD
Voltaje de CA
Escala
Precisión a
50 Hz a 60 Hz
600,0 ± (1,0% + 0,5 V)
Voltaje de CC
Escala Precisión
600,0 ± (1,0% + 0,5 V)
Voltaje de CA + CC
(CM-960 y CMI-600
solamente))
Escala
Precisión en CC,
50 Hz a 60 Hz
600,0 ± (1,2% + 0,7 V)
Impedancia de entrada: 10 MΩ, 100 pF nominal
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
35
Medición de corriente
Mediciones típicas y precisión (continuación)
Función AmpTip™
Corriente µA CC
Corriente de μCC (CMH-600 y CMI-600 solamente)
Escala Precisión Voltaje de carga
200,0 μA ± (1,0% + 0,5 μA)
3,5 mV/μA
2000 μA ± (1,0% + 5 μA)
A
Hz
Corriente de CA AmpTip™
Escala
Escala de
precisión
Precisión a
50 Hz a 60 Hz**
60,00 A
< 0,20 A* No especificada
0,00 A a 3,99 A ± (1,5% + 0,15 A)
4,00 A a 60,00 A ± (1,5% + 0,05 A)
* Para CM-660, CM-860 y CMH-600 solamente.
** Para CM-960 y CMI-600 solamente, el error
inducido por conductores adyacentes portadores
de corriente es < 0,01 A/A.
Corriente de CC AmpTip™
(CM-960 y CMI-600 solamente)
Escala
Escala de
precisión
Precisión†
60,00 A
0,00 A a 3,99 A ± (2,0% + 0,15 A)
4,00 A a 60,00 A ± (2,0% + 0,05 A)
Corriente de CC + CA AmpTip™
(CM-960 y CMI-600 solamente)
Escala
Escala de
precisión
Precisión en CC,
50 Hz a 60 Hz†
60,00 A
0,00 A a 3,99 A ± (2,0% + 0,17 A)
4,00 A a 60,00 A ± (2,0% + 0,07 A)
† El error inducido para conductores adyacentes portadores de corriente
es < 0,01 A/A.
Nota: Use Δ si hay una desviación antes de que se tome la medición.
Flame Sensor
Control
Board
Pilot Flame
µA
Sensor de llama
Llama piloto
Tarjeta de
control
36
Mediciones típicas y precisión (continuación)
Medición de corriente
(continuación)
Pinza para CA y CC
A
Hz
Corriente de CA (CM-960 y CMI-600 solamente)
Escala Escala de precisión
Precisión a
50 Hz a 100 Hz*†
Precisión a
100 Hz a 400 Hz*†
60,00 A
0,00 A a 8,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
9,00 A a 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A a 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Factor de cresta máximo < 2:1 a escala completa y < 4:1 a media escala.
Corriente de CA (CM-660, CM-860, y CMH-600 solamente)
Escala Escala de precisión
Precisión a
50 Hz a 100 Hz*†
Precisión a
100 Hz a 400 Hz*†
60,00 A
0,00 A a 0,19 A No especificada No especificada
0,20 A a 5,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
6,00 A a 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A a 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Para cualquier medición, cuando el conductor no esté posicionado en el centro de las
mordazas, agregue 2,0% a la precisión para compensar el error de posición.
Corriente de CC (CM-960 y CMI-600 solamente)
Escala Escala de precisión Precisión†
60,00 A
0,00 A a 8,99 A ± (2,0% + 0,15 A)
9,00 A a 60,00 A ± (2,0% + 0,05 A)
600,0 A 60,0 A a 600,0 A ± (2,0% + 0,5 A)
Corriente de CA + CC (CM-960 y CMI-600 solamente)
Escala Escala de precisión
Precisión a
50 Hz a 100 Hz†
Precisión a
100 Hz a 400 Hz†
60,00 A
0,00 A a 8,99 A ± (2,2% + 0,15 A) ± (2,7% + 0,17 A)
9,00 A a 60,00 A ± (2,2% + 0,05 A) ± (2,7% + 0,07 A)
600,0 A 60,0 A a 600,0 A ± (2,2% + 0,5 A) ± (2,7% + 0,7 A)
† El error inducido para conductores adyacentes portadores de corriente es < 0,01 A/A.
Nota: Use Δ si hay una desviación antes de que se tome la medición.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
37
Mediciones típicas y precisión (continuación)
Ω
SELECT
Medición
de resistencia
SELECT
Verificación de continuidad
Resistencia
Escala Precisión
600,0 Ω ± (1,0% + 0,5 Ω)
6,000 kΩ ± (1,0% + 0,005 kΩ)
60,00 kΩ ± (1,0% + 0,05 kΩ)
Voltaje de circuito abierto: 1,0 V CC
Continuidad
Umbral de tono: Entre 10 Ω y 250 Ω
Tiempo de respuesta: Aproximadamente 32 ms.
Medición
de capacitancia
Capacitancia (CM-860, CM-960,
CMH-600, y CMI-600 solamente)
Escala Precisión*
200,0 μF ± (2,0% + 0,4 μF)
2500 μF ± (2,0% + 4 μF)
* Para los capacitores de película
(capacitores con absorción
dieléctrica insignificante).
Nota: Para condensadores polarizados, conecte
la sonda roja al terminal positivo y la sonda
negra al terminal negativo del condensador.
38
Mediciones típicas y precisión (continuación)
Polarización
inversa
Polarización
directa
SELECT
Verificación de diodo
Verificación de diodos
Escala de medición: 2,000 V
Precisión: ± (1,5% + 0,005 V)
Corriente de prueba (típica): 0,3 mA
Voltaje de circuito abierto (típica):
< 3,5 V CC
Temperatura
SELECT
Temperatura (CMH-600 y CMI-600)
Escala Precisión*
-40,0 °C ~ 99,9 °C ± (1,0% + 0,8 °C)
100 °C ~ 400 °C ± (1,0% + 1 °C)
-40,0 °F ~ 211,8 °F ± (1,0% + 1,5 °F)
212 °F ~ 752 °F ± (1,0% + 2 °F)
* La precisión del termopar tipo K no está incluida.
Los termopares suministrados con el medidor
cumplen las normativas JIS C 16021981.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
39
Mediciones típicas y precisión (continuación)
A
10 mm
(0.4")
B
SELECT
Campo eléctrico
Nota: CM-660 y
CM-860 tienen una
posición dedicada de
interruptor.
A–Sin contacto O BIEN
B–Con contacto, medición de
precisión
Detección de EF sin contacto
Voltaje
típico
Escala de
50 Hz a 60 Hz
Indicación
en LCD
20 V 10 V ~ 36 V -
55 V 23 V ~ 83 V - -
110 V 59 V ~ 165 V - - -
220 V 124 V ~ 330 V - - - -
440 V 250 V ~ 600 V - - - - -
Rotación de fase Rotación del motor
Clockwise Counterclockwise
SELECT
A la derecha A la izquierda
40
Especificaciones
Pantalla: LCD, 3-5/6 dígitos 6000 puntos
Polaridad: Automática
Frecuencia de actualización: 5 por segundo, nominal
Condiciones de funcionamiento:
0 °C a 31 (32 °F a 88 °F), 0% a 80% de humedad relativa
31 °C a 40 (88 °F a 104 °F), humedad relativa disminuyendo linealmente
de 80% a 50%
Grado de contaminación: 2
Uso en interiores únicamente
Altitud: Funcionando por debajo de 2000 m (6500 pies)
Temperatura de almacenamiento: -20 °C a 60 °C, humedad relativa < 80%, sin baterías
Coeficiente de temperatura: Nominal 0,15 x (Precisión) por °C debajo de 18 °C desde
0 °C hasta 18 °C (32 °F hasta 64,4 °F) y por encima de 28 °C, desde 28 °C hasta
40 °C (82,4 °F hasta 104 °F) a menos que se especifique de manera diferente
Detección: Valores eficaces (RMS) reales
E.M.C.:
Cumple EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8,
EN61000-4-11)
En un campo de RF de 1 V/m a una frecuencia de 405 MHz, CC A y modo CC+CA A
(CM-960 y CMI-960): Precisión total = Precisión especificada + 20 dígitos
En un campo de RF de 1 V/m, modo Resistencia (todos los modelos) y modo µA CC
(CMH-600 y CMI-600): Precisión total = Precisión especificada + 25 dígitos
En un campo de RF de 3 V/m, y todos los otros modos y modelos no especificados
anteriormente: Precisión total = Precisión especificada + 20 dígitos
Seguridad: Doble aislamiento según UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed.
1, CAN/CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 2 y IEC/EN61010-
031 Ed. 1.1 para CAT III 600 V y CAT IV 300 V CA y CC
Protecciones contra sobrecarga:
Mordazas:
Función Corriente con frecuencia: 600 A CC/CA RMS a ≤ 400 Hz
Terminales:
Función Voltaje y Rotación de fase: 660 V CC/920 V CA RMS
Todos los otros modos y funciones: 600 V CC/CA RMS
Protección contra corrientes transitorias: 6,0 kV (1,2/50 µs sobrevoltaje)
Fuente de alimentación: Dos baterías de 1,5 V AAA (NEDA 24 A o IEC LR03)
Batería baja:
Función Capacitancia y Frecuencia: Aproximadamente 2,85 V
Toda otra función: Aproximadamente 2,5 V
Consumo de corriente:
CM-960 y CMI-600: Típicamente 13 mA
CM-660, CM-860 y CMH-600: Típicamente 4,3 mA
Sincronización de APO: Marcha en vacío durante 32 minutos
Consumo de APO: 5 µA típico
Dimensiones:
CM-960 y CMI-600: 222 mm x 76 mm x 37 mm (8,7 pulg. x 3,0 pulg. x 1,4 pulg.)
CM-660, CM-860 y CMH-600: 217 mm x 76 mm x 37 mm
(8,5 pulg. x 3,0 pulg. x 1,4 pulg.)
Apertura de mordazas y diámetro del conductor: 30 mm máx. (1,18 pulg.)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
41
Categorías de medición
Las siguientes definiciones proceden de la norma de seguridad internacional sobre
la coordinación de aislamientos tal y como se aplica a equipos de medición, control
y laboratorio. En las publicaciones IEC 61010-1 y IEC 60664 de la International
Electrotechnical Commission (Comisión Electrotécnica Internacional) se detallan más a
fondo estas categorías de medición.
Categoría de medición II
Nivel local. Aparatos eléctricos, equipo portátil, y los circuitos a los que están
conectados. Como ejemplo pueden citarse dispositivos de iluminación, televisores y
circuitos de rama larga.
Categoría de medición III
Nivel de distribución. Máquinas instaladas permanentemente y los circuitos a los que
están cableados. Como ejemplo pueden citarse sistemas conductores y los paneles del
interruptor automático principal del sistema eléctrico de un edificio.
Categoría de medición IV
Nivel de abastecimiento primario. Líneas aéreas y otros sistemas de cable. Como
ejemplo pueden citarse cables, medidores, transformadores y cualquier otro equipo
exterior perteneciente a la empresa de servicio eléctrico.
Certificado de Conformidad
Greenlee Tools, Inc. cuenta con certificación conforme a ISO 9001 (2000) para nuestros
Sistemas de Gerencia de Calidad.
El instrumento provisto ha sido inspeccionado y/o calibrado mediante el uso de equipo
reconocido por el Instituto Nacional de Normas y Tecnologías (National Institute for
Standards and Technology [NIST]).
42
Mantenimiento
Peligro de electrocución:
Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad.
De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la
muerte.
Reemplazo de las baterías
1. Desconecte la unidad del
circuito. Apague (OFF) la
unidad.
2. Extraiga los dos tornillos de la
puerta de acceso a la batería y
retírela.
3. Cambie las baterías y verifique
la polaridad, limpieza y
almacenamiento.
Limpieza y almacenamiento
Limpie periódicamente la caja
utilizando un paño húmedo y
detergente suave; no utilice
abrasivos ni solventes.
Si el medidor no se utilizará
durante períodos de más de 60
días, extraiga la batería y guárdela
separadamente.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
43
Description
Les contrôleurs à pince CM-660, CM-860, CM-960, CMH-600 et CMI-600 de
Greenlee sont des appareils de contrôle portables offrant les capacités de mesure
suivantes: tension alternative et continue, intensité alternative, AmpTip™ pour
intensité alternative, fréquence, détection de champ électrique (EF) sans contact
et résistance. Ils permettent également la vérification de diodes et les contrôles de
continuité. Ces contrôleurs sont conçus pour être utilisés sur des conducteurs isolés ou
non isolés.
Fonctionnalités supplémentaires propres à certains modèles :
Fonction CMI-600 CM-960 CMH-600 CM-860
Tension alternative + continue
AmpTip™ pour intensité
continue
AmpTip™ pour intensité
cont. + alt.
Intensité continue
Micro-intensité continue
Température
(thermocouple de type K)
Rotation de moteur
Rotation de phase
Saisie de valeurs efficaces
de crête
Capacité
Rétroéclairage
Mode zéro
Autres capacités :
• Mode de maintien pour saisir la valeur affichée en cours
• Mode d’enregistrement de minimum, maximum ou moyenne
• Mise hors tension automatique intelligente
• Sélection automatique du calibre
Sécurité
Lors de l’utilisation et de l’entretien des outils et des équipements de Greenlee, votre
sécurité est une priorité. Ce manuel d’instructions et toute étiquette sur l’outil fournit
des informations permettant d’éviter des dangers ou des manipulations dangereuses
liées à l’utilisation de cet outil. Suivre toutes les consignes de sécurité indiquées.
Dessein de ce manuel
Ce manuel a pour objet de familiariser l’utilisateur avec les procédures préconisées
pour une utilisation et un entretien sans danger des contrôleurs à pince CM-660,
CM-860, CM-960, CMH-600, et CMI-600 de Greenlee.
Mettre ce manuel à la disposition de tous les employés. On peut obtenir des
exemplaires gratuits sur simple demande sur le site Web www.greenlee.com.
44
SYMBOLE D’AVERTISSEMENT
Ce symbole met en garde contre les risques et les manipulations dangereuses
pouvant entraîner des blessures ou l’endommagement du matériel. Le mot
indicateur, défini ci-dessous, indique la gravité du danger. Le message qui suit le
mot indicateur indique comment empêcher le danger.
Danger immédiat qui, s’il n’est pas pris en considération ENTRAINERA des
blessures graves, voire mortelles.
Danger qui, s’il n’est pas pris en considération, POURRAIT entraîner des blessures
graves, voire mortelles.
Dangers ou manipulations dangereuses qui, s’ils ne sont pas pris en considération,
POURRAIENT EVENTUELLEMENT entraîner des dommages à la propriété ou causer
des blessures.
Lire attentivement et bien comprendre cette documentation
avant d’utiliser ou de procéder à l’entretien de cet équipement.
Négliger de comprendre comment utiliser cet outil en toute
sécurité pourrait provoquer un accident et entraîner des blessures
graves, voire mortelles.
Risque de décharge électrique :
Un contact avec des circuits sous tension pourrait entraîner des
blessures graves, voire mortelles.
Consignes de sécurité importantes
Ne pas se débarrasser de ce produit ou le jeter !
Pour des informations sur le recyclage, visiter www.greenlee.com.
Toutes les spécifications sont nominales et peuvent changer avec l’amélioration de la conception.
Greenlee Tools, Inc. ne peut être tenue responsable des dommages résultant d’une application
inappropriée ou d’un mauvais usage de ses produits.
® Déposé : La couleur verte des instruments de vérification électrique est une marque déposée de
Tools,Innovations Inc.
AmpTip est une marque de commerce de BTC.
CONSERVER CE MANUEL
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
45
Consignes de sécurité importantes
Risques de décharge électrique et d’incendie:
• Ne pas exposer cet appareil à la pluie ou à l’humidité.
• Ne pas utiliser cet appareil s’il est mouillé ou endommagé.
• Le contrôleur à pince, les fils de mesure ou tout autre accessoire de la pince,
lorsqu’ils sont utilisés pour effectuer une mesure, constituent un système. Ce
système est classé CAT III 600 V ou CAT IV 300 V si les fils de mesure ou les
accessoires fournis avec l’appareil sont utilisés. La catégorie (CAT) et la classe de
tension du système sont limités par l’élément du système de classe la plus basse
en cas d’utilisation de fils de mesure ou d’accessoires non fournis avec l’appareil
• Vérifier les fils de mesure ou l’accessoire avant de les utiliser. Ils doivent être
propres et secs et l’isolation doit être en bon état. Ne pas utiliser un fil de mesure si
la gaine isolante intérieure de couleur contrastée est visible.
• Utiliser cet appareil uniquement dans le but pour lequel il a été conçu, tel que décrit
dans ce manuel. Toute autre utilisation peut altérer le système de protection de cet
appareil.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire
mortelles.
Risques de décharge électrique:
• Ne pas appliquer plus que la tension nominale entre deux bornes d’entrée, ou entre
une borne d’entrée et une prise de terre.
• Tenir les mains et les doigts en dessous des gardes sur les fils de mesure et le
corps du contrôleur à pince.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire
mortelles.
Risques de décharge électrique:
• Ne pas utiliser lorsq ue le boîtier est ouvert.
• Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors
tension.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire
mortelles.
46
Consignes de sécurité importantes
Risques de décharge électrique:
• Sauf si l’on mesure la tension, le courant ou la fréquence, mettre hors tension
et couper la source d’alimentation. S’assurer que tous les condensateurs sont
déchargés. Aucune tension ne doit être présente.
• Régler le sélecteur et raccorder les fils de mesure comme il se doit pour la mesure
à effectuer. Des réglages ou branchements incorrects peuvent produire des
mesures inexactes ou endommager l’appareil.
• L’utilisation de cet appareil à proximité d’équipements qui génèrent des
interférences électromagnétiques peut produire des lectures instables ou erronées.
L’inobservation de ces consignes pourrait entraîner des blessures graves, voire
mortelles.
Risques de décharge électrique:
• Ne pas modifier la fonction de mesure pendant que les fils d’essai sont connectés à
un composant ou à un circuit.
• Ne pas placer la mâchoire autour d’un conducteur transportant un courant de plus
de 400 Hz de fréquence. Le circuit magnétique peut atteindre une température
dangereuse en cas de dépassement de cette fréquence.
L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner
des blessures.
Risques de décharge électrique:
• Ne pas tenter de réparer cet appareil. Il ne comporte aucune pièce pouvant être
réparée.
• Ne pas exposer l’appareil à des températures ou à une humidité extrêmes.
Voir les caractéristiques techniques.
L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner
des blessures.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
47
Identification
1. Antenne pour détection de champ électrique (EF) sans contact
2. Indicateur de centre de mâchoire pour mesurer les intensités avec précision ;
indicateur de polarité pour les intensités continues
3. Sélecteur de fonction ou de mise hors tension
4. Écran à cristaux liquides
5. Prise d’entrée pour la détection de rotation de phase et de moteur seulement
6. Borne d’entrée positive ; entrée L2 pour rotation de moteur et de phase
7. Borne d’entrée négative, commune ou de terre ; entrée L1 pour rotation de moteur
et de phase
8. Voir l’explication sous « Utilisation des fonctions »
9. Levier de mâchoire
10. Garder les mains et les doigts sous le trait pointillé durant l’utilisation.
11. Mâchoire
12. Indicateur de centre pour la fonction AmpTip™
12
11
1
2
3
4
6
5
9
10
8
7
Symboles sur l’appareil
Avertissement — Lire le mode d’emploi
Avertissement — Risque de décharge électrique
Terre
Double isolation
Courant alternatif (AC)
Courant continu (DC)
Peut être placé autour de conducteurs sous tension dangereuse
ou en être enlevé.
48
Icônes de l’afficheur
1. Sélection de calibre automatique activée
2. Fonction d’enregistrement activée
3. Diode
4. Continuité
5. Mode crête-efficace activé
6. Rotation de phase alimentation principale
7. Rotation de moteur
8. 8.8.8.8 Affichage numérique
9. µ Micro (10
-6
)
10. F Farad
11. A Ampère
12. V Volt
13. Hz Hertz (fréquence en cycles par seconde)
14. Ω Ohm
15. k Kilo (10
3
)
16. Fonction AmpTip™ activée
17. Fonction de zéro relatif activée
18. Indicateur de polarité
19. VFD Filtre pour mesures en courant alternatif exactes
sur les variateurs de vitesse (VFD)
20. Mesure de courant alternatif sélectionnée
21. + Mesure de courant alternatif + continu sélectionnée
22. Mesure de courant continu sélectionnée
23. Pile déchargée
24. Fonction de rétention activée
25. MAX Valeur maximale affichée
26. MIN Valeur minimale affichée
27. AVG Valeur moyenne affichée
6-7
23-27
18
17
22
28
20
19
21
8
9-12
1
16 15 14 13
2 3 4 5
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
49
Utilisation des fonctions
Tous les modèles
REC : Appuyer brièvement pour activer le mode d’enregistrement MAX/MIN/AVG.
et « MAX MIN AVG » s’affichent à l’écran. L’appareil émet un bip à chaque mise à jour
du maximum ou du minimum. La mesure moyenne (AVG) est calculée sur la durée.
Appuyer brièvement sur cette touche pour afficher successivement les mesures
MAX, MIN et AVG. Appuyer sur la touche pendant 1 seconde pour quitter le mode
d’enregistrement MAX/MIN/AVG. L’APO est désactivé automatiquement dans ce mode.
SELECT : Appuyer brièvement pour passer d’une fonction, d’un mode de mesure
ou d’un mode d’affichage à l’autre. Le dernier réglage utilisé devient le réglage par
défaut lorsque la fonction considérée est sélectionnée une nouvelle fois. Pour changer
de réglage par défaut, en sélectionner un nouveau. Le réglage est conservé dans une
mémoire non volatile.
HOLD : Appuyer brièvement pour figer l’affichage de la valeur courante. Appuyer une
nouvelle fois pour quitter ce mode.
Mise hors tension automatique intelligente (APO) : L’appareil s’éteint
automatiquement au bout de 32 minutes d’inactivité environ pour économiser la pile.
Le contrôleur est considéré comme actif dans les cas suivants : sélecteur tourné ou
bouton-poussoir enfoncé ; mesures supérieures à 8,5 % du calibre ; mesures sans
surcharge de résistance, de continuité ou de fonction de diode ; mesure de fréquence
non nulle ; segment de rotation de phase en mouvement. Pour réactiver le contrôleur
depuis le mode APO, appuyer brièvement sur la touche SELECT ou placer le bouton
sélecteur tournant sur OFF puis le ramener en position de marche. Toujours mettre le
sélecteur tournant en position OFF lorsque le contrôleur n’est pas utilisé.
CM-860, CM-960, CMH-600 et CMI-600 seulement
: Appuyer sur la touche SELECT pendant 1 seconde pour allumer et éteindre le
rétroéclairage de l’écran. Le rétroéclairage s’éteint automatiquement au bout de 32
secondes pour économiser la pile.
∆ : Appuyer sur la touche pendant 1 seconde pour alterner entre le mode zéro et le
mode normal. En mode zéro, la valeur à l’écran au moment où la touche est enfoncée
devient le facteur de correction. À mesure que la valeur d’entrée varie, ce facteur
de correction est retranché de la valeur mesurée. L’écran affiche la valeur modifiée
résultante.
Remarque : L’utilisation de lorsque les fonctions d’intensité continue ou d’intensité
continue + alternative sont sélectionnées a pour effet de décaler l’hystérésis mag-
nétique dans la mâchoire. Si la valeur d’intensité continue ou continue + alternative
avant la mesure n’est pas nulle, appuyer sur la touche pendant 1 seconde. L’écran
affiche alors « dc_0 ». Quand ce message s’efface, l’appareil est prêt à l’utilisation.
Lors de mesures de plus de 5 A, ce mode est désactivé. L’appareil émet alors trois
bips pour l’indiquer.
CM-960, CMH-600 et CMI-600 seulement
PEAK-RMS : Appuyer sur la touche PEAK-RMS pendant 1 seconde pour activer le
mode PEAK-RMS (crête-efficace) afin d’effectuer l’acquisition de l’intensité ou la
tension d’appel pendant une durée de 80 ms ou plus. s’affiche à l’écran.
Appuyer sur la touche pendant 1 seconde pour quitter le mode PEAK-RMS. L’APO est
désactivé automatiquement dans ce mode.
CMH-600 et CMI-600 seulement
et : Le cas échéant, tenir la touche REC enfoncée durant la mise en marche
de l’appareil pour activer la fonction de bip. Si les segments indiquent un mouvement
dans le sens des aiguilles d’une montre, l’appareil émet un bip long unique par cycle.
Si les segments indiquent un mouvement dans le sens inverse, l’appareil émet trois
bips courts par cycle.
: S’assurer que le moteur est isolé électriquement de sa source
d’alimentation. Appuyer brièvement sur la touche SELECT pour sélectionner la
fonction Moteur. Raccorder l’appareil au moteur conformément aux indications de
la section « Tableau des réglages » de ce manuel. Faire tourner l’arbre du moteur
dans le sens des aiguilles d’une montre, vu depuis le côté arbre du moteur. Si
l’appareil indique un mouvement dans le sens des aiguilles d’une montre, les fils
50
Utilisation des fonctions (suite)
du moteur raccordés à L1, L2 et L3 sur l’appareil sont, respectivement, T1, T2
et T3. Si l’appareil indique un mouvement inverse, inverser deux raccordements
quelconques entre le contrôleur et le moteur. Refaire ensuite l’essai.
: Appuyer brièvement sur la touche SELECT pour sélectionner la fonction
Phase. Raccorder l’appareil aux phases conformément aux indications de
la section « Tableau des réglages » de ce manuel. Si l’appareil indique un
mouvement dans le sens des aiguilles d’une montre, les phases raccordées à L1,
L2 et L3 sur l’appareil sont, respectivement, L1, L2 et L3. Si l’appareil indique un
mouvement inverse, inverser deux raccordements quelconques entre le contrôleur
et les phases. Refaire ensuite l’essai.
Utilisation des fils de mesure
Danger de choc électrique :
Les fils de mesure fournis avec ce produit sont conformes à des normes de sécurité
qui limitent la longueur exposée d’embout de sonde à 4 mm pour les catégories de
mesure III et IV. Ces fils de mesure comportent un capuchon qui doit être en place
pour effectuer des mesures de catégorie III ou IV.
Le non-respect de cette mise en garde peut entraîner des blessures graves ou la
mort.
Le capuchon doit être en place pour effectuer des mesures de catégorie III ou IV.
Le capuchon peut être retiré pour les mesures de catégorie I ou II.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
51
Mesure de courant alternatif
En règle générale, les mesures de courant alternatif sont affichées en valeurs efficaces
(RMS). La valeur efficace équivaut à la valeur d’une forme d’onde de courant continu,
qui fournirait la même puissance si elle remplaçait la forme d’onde qui varie en fonction
du temps. Les deux méthodes de mesure du courant alternatif sont la mesure de valeur
efficace de réponse moyenne étalonnée et la mesure de valeur efficace vraie.
La méthode par valeur efficace de réponse moyenne étalonnée consiste à mesurer
la valeur moyenne du signal d’entrée après un redressement à double alternance, à
la multiplier par 1,11 et à afficher le résultat. Cette méthode est précise si le signal
d’entrée est une onde sinusoïdale pure.
La méthode par mesure de la valeur efficace vraie fait appel à un circuit interne
permettant de mesurer directement la valeur efficace. Cette méthode est précise
dans les limites du facteur de crête spécifiées, que le signal soit une onde sinusoïdale
pure, une onde carrée, une onde triangulaire, une demi-onde ou un signal comportant
des harmoniques. Les appareils à mesure de valeur efficace vraie sont beaucoup
plus polyvalents que les appareils conventionnels. Les contrôleurs CM-660, CM-860,
CM-960, CMH-600, et CMI-600 de Greenlee sont des multimètres à valeur efficace
vraie (True RMS).
Le tableau des formes d’onde et facteurs de crête fournit les valeurs efficaces des
signaux alternatifs courants.
Formes d’ondes et facteurs de crêtes
Forme d’onde
Valeur RMS 100 100 100 100
Valeur moyenne 90 100 87 64
Facteur de crête* (x) 1,414 1 1,73 2
* Le facteur de crête correspond au rapport de la valeur de crête sur la valeur
efficace; il est représenté par la lettre grecque x.
Valeur efficace vraie AC + DC
La valeur efficace vraie AC + DC distingue les composantes alternative et continue
suivant l'expression données par l’expression
lors de la prise des mesures et reproduit avec précision la valeur efficace vraie totale
réelle indépendamment de la forme d’onde. Les formes d’ondes déformées par la
présence de composantes continues et d’harmoniques peuvent entraîner:
• une surchauffe des transformateurs, des groupes électrogènes et des moteurs
• un déclenchement prématuré des disjoncteurs
• une condition où les fusibles vont griller
• une surchauffe des neutres à cause de la triple harmonique présente dans le neutre
• une vibration des barres omnibus et des panneaux électriques
Les modèles CM-960 et CMI-600 peuvent être configurés pour afficher les valeurs
efficaces vraies des mesures de courant alternatif ou de courant alternatif + continu.
52
Bande passante en courant alternatif
La bande passante en courant alternatif est la plage de fréquences sur laquelle les
mesures de courant alternatif peuvent être effectuées dans les limites d’incertitude
indiquées. Il s’agit de la réponse en fréquence des fonctions de mesure en courant
alternatif, pas des fonctions de mesure de fréquence. Une valeur de courant alternatif
ne peut pas être mesurée avec précision dans des spectres de fréquence en dehors de
la bande passante de l’appareil. Les formes d’onde complexes, le bruit et les formes
d’onde ayant subi une distorsion contiennent des composantes de fréquence beaucoup
plus élevée que la fondamentale. Exemple : le bruit haute fréquence sur une ligne haute
tension de 50 ou 60 Hz.
Utilisation
Risque de décharge électrique :
Un contact avec des circuits sous tension pourrait entraîner des
blessures graves, voire mortelles.
Mode d'emploi
1. Se reporter au Tableau des réglages. Placer le sélecteur sur le réglage qui convient,
appuyer sur SELECT (lorsque l'instruction en est donnée) et raccorder les fils
d'essai au multimètre.
2. Voir les instructions de mesure particulières sous « Mesures types ».
3. Tester l’appareil sur un circuit ou un composant connu.
• Si l’appareil ne fonctionne pas comme prévu sur un circuit opérationnel connu,
changer les piles.
• Si l’appareil ne fonctionne toujours pas comme prévu, appeler le service
d'assistance technique de Greenlee au 800-435-0786.
4. Effectuer la mesure sur le circuit ou le composant à contrôler.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
53
Tableau des réglages
Pour mesurer
cette valeur …
Régler le
sélecteur sur
ce symbole …
Ces icônes
s’affichent à
l’écran …
Raccorder
le fil rouge
à …
Raccorder
le fil noir
à …
TOUS MODÈLES
Tension (alternative)
V
+ COM
Tension (continue)
V
+ COM
Intensité, AmpTip™ (alt.)
A
Néant Néant
Intensité (alternative)
A
Néant Néant
Continuité
Ω
+ COM
Résistance
Ω
+ COM
Diode
V
+ COM
Fréquence
Hz Hz
+ COM
Champ électrique (EF)*
EF EF
Néant COM
CM-860, CM-960, CMH-600 et CMI-600 seulement
Capacité**
µF
+ COM
CM-960 et CMI-600 seulement
Tension (alt. + cont.) + COM
Intensité, AmpTip™ (cont.)
A
Néant Néant
Intensité, AmpTip™
(alt. + cont.)
A
Néant Néant
Intensité (continue)
A
Néant Néant
Intensité
(alternative + continue)
A
Néant Néant
CMH-600 et CMI-600 seulement
Température
Temp C ou F
***
Intensité (micro, alt.)
µA
+ COM
Rotation de phase† + COM
Rotation de moteur† + COM
* Utiliser la partie supérieure de la mâchoire fixe ou, pour obtenir des mesures plus
précises, utiliser une sonde branchée sur la borne COM.
** Décharger les condensateurs avant la mesure. Voir « Mesures types » concernant
les condensateurs polarisés.
*** Le + du thermocouple sur +, le – du thermocouple sur COM.
Fil jaune sur L3.
Utilisation (suite)
54
Mesures types et incertitude
Voir les conditions d’utilisation et le coefficient de température dans la section «
Caractéristiques techniques ».
L’incertitude est spécifiée comme suit : ± (un pourcentage de la mesure + une quantité
fixe) à 23 °C ± 5 °C (73,4 °F ± 9 ºF).
La fréquence doit être dans les limites de la largeur de bande spécifiée pour les ondes
non sinusoïdales. Sauf indication contraire, les facteurs de crête sont les suivants :
• Facteur de crête < 2,5:1 à pleine échelle
• Facteur de crête < 5,0:1 à mi-échelle
Fréquence
Fonction Sensibilité (eff. sinus.)* Calibre
600 V 50 V 5,00 Hz ~ 999,9 Hz
60,0 A AmpTip™ 40 A 50,00 Hz ~ 400,0 Hz
60,00 A, 600,0 A 40 A 50,00 Hz ~ 400,0 Hz
* La tension de polarisation (DC Bias) doit être inférieure à 50 % de la valeur efficace
sinusoïdale.
Incertitude de la mesure de fréquence
Plage d’affichage Incertitude
xx.xx ± (1,0% + 0,05 Hz)
xxx.x ± (1,0% + 0,5 Hz)
Mesure de tension
VHz
EF
VFD
SELECT SELECT
VFD
Tension alternative
Calibre
Incertitude de
50 Hz à 60 Hz
600,0 ± (1,0% + 0,5 V)
Tension continue
Calibre Incertitude
600,0 ± (1,0% + 0,5 V)
Tension alt. + cont.
(CM-960, CMI-600
seulement)
Calibre
Incertitude
cour. cont., de
50 Hz à 60 Hz
600,0 ± (1,2% + 0,7 V)
Impédance d’entrée : 10 MΩ, 100 pF nominal
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
55
Mesure d’intensité de courant
Mesures types et incertitude (suite)
Fonction AmpTip™
µA continu
Micro-intensité continue (CMH-600 et CMI-600 seulement)
Calibre Incertitude Tension absorbée
200,0 μA ± (1,0% + 0,5 μA)
3,5 mV/μA
2000 μA ± (1,0% + 5 μA)
A
Hz
Intensité alternative AmpTip™
Calibre Plage de mesure
Incertitude de
50 Hz à 60 Hz**
60,00 A
< 0,20 A* Non spécifié
0,00 A à 3,99 A ± (1,5% + 0,15 A)
4,00 A à 60,00 A ± (1,5% + 0,05 A)
* CM-660, CM-860 et CMH-600 seulement.
** Pour CM-960 et CMI-600 seulement, l’erreur
induite pour les conducteurs voisins est
<0,01A/A..
Intensité continue AmpTip™
(CM-960 et CMI-600 seulement)
Calibre Plage de mesure Incertitude†
60,00 A
0,00 A à 3,99 A ± (2,0% + 0,15 A)
4,00 A à 60,00 A ± (2,0% + 0,05 A)
Intensité cont. + alt. AmpTip™
(CM-960 et CMI-600 seulement)
Calibre
Plage de
mesure
Incertitude
cour. cont., de
50 Hz à 60 Hz†
60,00 A
0,00 A à 3,99 A ± (2,0% + 0,17 A)
4,00 A à 60,00 A ± (2,0% + 0,07 A)
† L’erreur induite pour les conducteurs voisins est < 0,01 A/A.
Remarque : Utiliser Δ si une correction est nécessaire avant d’effectuer la mesure.
Flame Sensor
Control
Board
Pilot Flame
µA
Détecteur de
flamme
Veilleuse
Circuit de
commande
56
Mesures types et incertitude (suite)
Mesure d’intensité de
courant (suite)
Pince, courant alternatif
et continu
A
Hz
Intensité alternative (CM-960 et CMI-600 seulement)
Calibre Plage de mesure
Incertitude de
50 Hz à 100 Hz*†
Incertitude de
100 Hz à 400 Hz*†
60,00 A
0,00 A à 8,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
9,00 A à 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A à 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Le facteur de crête maximal est < 2:1 à pleine échelle et < 4:1 à mi-échelle.
Intensité alternative (CM-660, CM-860, et CMH-600 seulement)
Calibre Plage de mesure
Incertitude de
50 Hz à 100 Hz*†
Incertitude de
100 Hz à 400 Hz*†
60,00 A
0,00 A à 0,19 A Non spécifié Non spécifié
0,20 A à 5,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
6,00 A à 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A à 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Pour toute mesure, si le conducteur n’est pas placé au centre des mâchoires, ajouter
2,0 % d’incertitude pour l’erreur de position.
Intensité continue (CM-960 et CMI-600 seulement)
Calibre Plage de mesure Incertitude†
60,00 A
0,00 A à 8,99 A ± (2,0% + 0,15 A)
9,00 A à 60,00 A ± (2,0% + 0,05 A)
600,0 A 60,0 A à 600,0 A ± (2,0% + 0,5 A)
Intensité alt. + cont. (CM-960 et CMI-600 seulement)
Calibre Plage de mesure
Incertitude de
50 Hz à 100 Hz†
Incertitude de
100 Hz à 400 Hz†
60,00 A
0,00 A à 8,99 A ± (2,2% + 0,15 A) ± (2,7% + 0,17 A)
9,00 A à 60,00 A ± (2,2% + 0,05 A) ± (2,7% + 0,07 A)
600,0 A 60,0 A à 600,0 A ± (2,2% + 0,5 A) ± (2,7% + 0,7 A)
† L’erreur induite pour les conducteurs voisins est < 0,01 A/A.
Remarque : Utiliser Δ si une correction est nécessaire avant d’effectuer la mesure.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
57
Mesures types et incertitude (suite)
Ω
SELECT
Mesure de
résistance
SELECT
Contrôle de continuité
Résistance
Calibre Incertitude
600,0 Ω ± (1,0% + 0,5 Ω)
6,000 kΩ ± (1,0% + 0,005 kΩ)
60,00 kΩ ± (1,0% + 0,05 kΩ)
Tension en circuit ouvert : 1,0 VDC
Continuité
Seuil de tonalité : Entre 10 Ω et 250 Ω
Temps de réponse : 32 ms environ
Mesure de
capacité
Capacité (CM-860, CM-960,
CMH-600, et CMI-600 seulement)
Calibre Incertitude*
200,0 μF ± (2,0% + 0,4 μF)
2500 μF ± (2,0% + 4 μF)
* Pour les condensateurs à couches
(absorption diélectrique négligeable).
Remarque : Pour les condensateurs polarisés,
attacher le fil de mesure rouge à la borne
positive et le fil noir à la borne négative du
condensateur.
58
Mesures types et incertitude (suite)
Polarisation
inverse
Polarisation
directe
Mesure de diode
Contrôle de diode
Calibre de mesure : 2,000 V
Incertitude : ± (1,5 % + 0,005 V)
Intensité de contrôle (type) : 0,3 mA
Tension en circuit ouvert (type) :
< 3,5 VDC
Température
SELECT
Température (CMH-600 et CMI-600)
Calibre Incertitude*
-40,0 °C ~ 99,9 °C ± (1,0% + 0,8 °C)
100 °C ~ 400 °C ± (1,0% + 1 °C)
-40,0 °F ~ 211,8 °F ± (1,0% + 1,5 °F)
212 °F ~ 752 °F ± (1,0% + 2 °F)
* Incertitude des thermocouples de type K non
incluse. Le thermocouple fourni avec l’appareil
est conforme à la norme JIS C 16021981.
SELECT
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
59
Mesures types et incertitude (suite)
A
10 mm
(0.4")
B
SELECT
Champ électrique
Remarque : Les modèles
CM-660 et CM-860
comportent une position
spécifique du sélecteur.
A – Sans contact OU
B – Avec contact, mesure de
précision
Détection de champ électrique
sans contact
Tension
type
Plage, de
50 Hz à 60 Hz
Affichage
20 V 10 V ~ 36 V -
55 V 23 V ~ 83 V - -
110 V 59 V ~ 165 V - - -
220 V 124 V ~ 330 V - - - -
440 V 250 V ~ 600 V - - - - -
Rotation de phase Rotation de moteur
Clockwise Counterclockwise
SELECT
Sens des aiguilles
d’une montre
Sens inverse des
aiguilles d’une montre
60
Caractéristiques techniques
Affichage : Écran à cristaux liquides (LCD), 3-5/6 digits, 6 000 points
Polarité : Automatique
Taux de rafraîchissement : 5 par seconde (nominal)
Conditions d’utilisation :
0 °C à 31 °C (32 °F à 88 °F), 0 % à 80 % d’humidité relative
31 °C à 40 °C (88 °F à 104 °F), l’humidité relative décroît linéairement
de 80 % à 50 %
Degré de pollution : 2
Utilisation à l’intérieur uniquement
Altitude : Utilisation : en dessous de 2 000 m (6 500 ft)
Température d’entreposage : -20 °C à 60 °C, humidité relative < 80 %, piles retirées
Coefficient de température : Nominal 0,15 x (incertitude) par °C en dessous de 18 °C
entre 0 °C et 18 °C (32 °F et 64,4 °F) ou au-dessus de 28 °C entre 28 °C et 40 °C
(82,4 °F et 104 °F), sauf indication contraire
Détection : Valeur efficace vraie
C.E.M. :
Conforme à EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11)
Dans un champ RF de 1 V/m à une fréquence de 405 MHz, modes intensité cont. et
intensité cont. + alt. (CM-960 et CMI-960) :
Incertitude totale = incertitude indiquée + 20 digits
Dans un champ RF de 1 V/m, modes résistance (tous modèles) et µA cont.
(CMH-600 et CMI-600) : Incertitude totale = incertitude indiquée + 25 digits
Dans un champ RF de 3 V/m, tous les autres modes et modèles non spécifiés
ci-dessus : Incertitude totale = incertitude indiquée + 20 digits
Sécurité : Double isolation selon UL/IEC/EN61010-1 Éd. 3, IEC/EN61010-2-033 Éd. 1,
CAN/CSA C22.2 n° 61010-1 Éd. 3, IEC/EN61010-2-032 Éd. 2 et IEC/EN61010-031
Éd. 1.1 jusqu’à CAT III 600 V et CAT IV 300 V alt. et cont.
Protections antisurcharge :
Mâchoires :
Fonctions d’intensité et de fréquence : 600 A DC/AC eff. à ≤ 400 Hz
Bornes :
Fonctions de tension et de rotation de phase : 660 V DC/920 V AC eff.
Tous autres modes et fonctions : 600 V DC/AC eff.
Protection contre les transitoires : 6,0 kV (surtension de 1,2/50 μs)
Alimentation : Deux piles de AAA de 1,5 V (NEDA 24A ou IEC LR03)
Piles déchargées :
Fonctions de capacité et de fréquence : 2,85 V environ
Toutes autres fonctions : 2,5 V environ
Consommation de courant :
CM-960 et CMI-600 : 13 mA typique
CM-660, CM-860 et CMH-600 : 4,3 mA typique
Temporisation d’arrêt automatique (APO) : 32 minutes d’inactivité
Consommation de l’APO : 5 μA typique
Dimensions :
CM-960 et CMI-600 : 222 mm x 76 mm x 37 mm (8,7” x 3,0” x 1,4”)
CM-660, CM-860 et CMH-600 : 217 mm x 76 mm x 37 mm (8,5” x 3,0” x 1,4”)
Ouverture de la pince et diamètre de conducteur : 30 mm max. (1,18”)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
61
Catégories de mesure
Ces définitions sont dérivées des normes internationales sur la sécurité pour la
coordination de l’isolation telle qu’elle s’applique à la mesure, au contrôle et à
l’équipement de laboratoire. Ces catégories de mesure sont expliquées plus en détail
par la Commission électrotechnique internationale ; se reporter à l’une de ces deux
publications : IEC 61010-1 ou IEC 60664.
Catégorie de mesure II
Niveau local. Appareils, équipement portatif et les circuits dans lesquels ils sont
branchés. Par exemple, les appareils d’éclairage, les téléviseurs et les dérivations.
Catégorie de mesure III
Niveau de distribution. Les machines installées en permanence et les circuits auxquels
elles sont câblées. Par exemple, les systèmes de convoyeurs et les panneaux de
disjoncteurs principaux du système électrique d’un édifice.
Catégorie de mesure IV
Niveau d’alimentation principal. Lignes surélevées et autres systèmes de câbles.
Par exemple, les câbles, les compteurs, les transformateurs et autres équipements
extérieurs appartenant aux fournisseurs en électricité.
Déclaration de conformité
Greenlee Tools, Inc. est certifiée selon ISO 9001 (2000) pour nos Systèmes de gestion
de la qualité.
L’instrument ci-inclus a été vérifié et/ou étalonné avec des moyens de mesure
raccordés aux étalons du National Institute of Standards and Technology (NIST).
62
Entretien
Risques de décharge électrique:
Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors
tension.
L’inobservation de cette consigne pourrait entraîner des blessures graves, voire
mortelles.
Changer les piles
1. Débrancher l’appareil du circuit.
Mettre l’appareil hors tension
(OFF).
2. Ôter les deux vis du couvercle
d’accès à la pile et enlever le
couvercle.
3. Changer les piles en veillant à
respecter la polarité.
Nettoyage et entreposage
Essuyer régulièrement le boîtier
avec un chiffon humide et un
détergent doux. Ne pas utiliser de
produit abrasif ni de solvant.
Si le multimètre doit rester inutilisé
pendant des durées de plus de
60 jours, sortir les piles et les
entreposer séparément.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
63
Beschreibung
Die Zangenmessgeräte CM-660, CM-860, CM-960, CMH-600 und CMI-600 von
Greenlee sind Handmessgeräte mit den folgenden Messfähigkeiten: Wechsel- und
Gleichspannung, Wechselstrom, Wechselstrom mit AmpTip™, Frequenz, kontaktloser
Nachweis eines elektrischen Feldes (EF) und Widerstand. Sie können zudem zur
Überprüfung von Dioden und zur Durchgangsprüfung eingesetzt werden. Diese
Messgeräte sind für isolierte und nicht isolierte Leiter ausgelegt (Anbringen/Abnehmen).
Zusätzliche Funktionen der einzelnen Modelle:
Funktion CMI-600 CM-960 CMH-600 CM-860
Wechsel- und Gleichspannung
Gleichstrom mit AmpTip™
Gleich- und Wechselstrom mit
AmpTip™
Gleichstrom
Gleichstrom im µA-Bereich
Temperatur
(Thermoelement Typ K)
Motordrehung
Drehfeld
Spitzen-Effektivwert-Erfassung
Kapazität
Hintergrundbeleuchtung
Zero-Modus
Das Gerät bietet folgende weitere Funktionen:
• Haltemodus zur Erfassung des aktuellen LCD-Werts
• Aufzeichnungsmodus für Minimum, Maximum oder Durchschnitt
Intelligente Abschaltautomatik
• Automatische Bereichswahl
Sicherheitsvorkehrungen
Sicherheitsvorkehrungen sind bei der Verwendung und der Wartung der Geräte und
Ausrüstung von Greenlee entscheidend. Die vorliegende Anleitung und etwaige am
Gerät angebrachte Beschriftungen geben Hinweise zur Vermeidung von Gefahren und
gefährlichen Praktiken in Bezug auf die Handhabung dieses Geräts. Bitte alle hier
angegebenen Sicherheitshinweise beachten.
Zweck dieses Handbuchs
Dieses Handbuch ist dazu vorgesehen, das Personal mit den sicheren Betriebs- und
Wartungsverfahren für die Zangenmessgeräte CM-660, CM-860, CM-960, CMH-600
und CMI-600 von Greenlee vertraut zu machen.
Bitte dieses Handbuch allen Mitarbeitern zugänglich machen. Ersatz-Handbücher sind
auf Anfrage kostenlos erhältlich unter www.greenlee.com.
64
SICHERHEITS-WARNSYMBOL
Dieses Symbol macht auf gefährliche oder riskante Praktiken aufmerksam, die
zu Schäden oder Verletzungen führen können. Das Signalwort, wie nachfolgend
definiert, gibt den Schweregrad der Gefahr an. Der dem Signalwort folgende
Hinweis informiert darüber, wie die Gefahr verhindert oder vermieden wird.
Akute Gefahr, die bei Nichtvermeiden zu schweren Verletzungen oder zum Tod
FÜHRT.
Gefahr, die bei Nichtvermeiden zu schweren Verletzungen oder zum Tod führen
KANN.
Gefahr oder unsichere Praktiken, die bei Nichtvermeiden zu Verletzungen oder
Sachschäden führen KÖNNEN.
Vor Betrieb oder Wartung dieses Geräts die Bedienungsanleitung
sorgfältig durchlesen und beachten. Mangelndes Verständnis
der sicheren Betriebsweise dieses Geräts kann zu Unfällen mit
schweren oder tödlichen Verletzungen führen.
Stromschlaggefahr:
Das Berühren von Stromkreisen kann zu schweren Verletzungen
oder zum Tod führen.
Wichtige Sicherheitsinformationen
Dieses Produkt nicht wegwerfen.
Recycling-Informationen sind unter www.greenlee.com nachzulesen.
Alle technischen Daten sind Nennwerte. Bei Designverbesserungen sind Änderungen der Nennwerte
vorbehalten. Greenlee Tools, Inc. haftet nicht für Schäden, die sich aus der falschen Anwendung oder
dem Missbrauch seiner Produkte ergeben.
® Eingetragen: Die Farbe Grün für elektrische Testgeräte ist eine eingetragene Marke von Tools,
Innovations Inc.
AmpTip ist eine Marke von BTC.
DIESES HANDBUCH UNBEDINGT AUFBEWAHREN
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
65
Wichtige Sicherheitsinformationen
Stromschlag- und Brandgefahr:
• Dieses Gerät darf weder Regen noch Feuchtigkeit ausgesetzt werden.
• Das Gerät nicht benutzen, wenn es nass oder beschädigt ist.
• Zangenmessgerät, Messleitungen und alles andere Zubehör gelten als ein
System, wenn sie zusammen zur Messung verwendet werden. Das System ist
bei Verwendung der im Lieferumfang des Messgeräts enthaltenen Messleitungen
und Zubehörteile für Stromkreise CAT III 600 V oder CATIV 300 V ausgelegt.
Bei Verwendung von nicht mit dem Messgerät gelieferten Messleitungen oder
Zubehörteilen basiert die Systemauslegung in Bezug auf CAT und Spannung auf der
Komponente mit der niedrigsten Auslegung im System.
• Vor dem Einsatz die Messleitungen oder Zubehörteile überprüfen. Sie müssen
sauber und trocken und die Isolation muss in einem guten Zustand sein.
Messleitungen dürfen nicht verwendet werden, wenn die kontrastierende innere
Isolierung sichtbar ist.
• Dieses Gerät darf nur zu seinem vom Hersteller bestimmten Zweck wie
in dieser Anleitung beschrieben verwendet werden. Davon abweichende
Verwendungszwecke beeinträchtigen u.U. den vom Gerät gebotenen Schutz.
Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen
Verletzungen führen.
Stromschlaggefahr:
• Zwischen zwei Eingangsanschlüssen bzw. einem Eingangsanschluss und der
Erdung nicht mehr als die Nennspannung anlegen.
• Darauf achten, dass Hände und Finger unterhalb der Schutzbarrieren an den
Messleitungen und am Messgerätgehäuse bleiben.
Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen
Verletzungen führen.
Stromschlaggefahr:
• Das Gerät nicht mit offenem Gehäuse benutzen.
• Vor dem Öffnen des Gehäuses die Messleitungen vom Stromkreis entfernen und
das Gerät ausschalten.
Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen
Verletzungen führen.
66
Wichtige Sicherheitsinformationen
Stromschlaggefahr:
• Das Gerät ausschalten und die Stromzufuhr blockieren, wenn es nicht zur Messung
von Stromstärke, der Spannung oder Frequenz eingesetzt wird. Darauf achten, dass
alle Kondensatoren entladen sind. Es darf keine elektrische Spannung vorhanden
sein.
• Den Wahlschalter gemäß der vorzunehmenden Messung einstellen und die
Messleitungen entsprechend anschließen. Falsche Einstellungen oder falsches
Anlegen können zu Messfehlern oder Geräteschäden führen.
• Die Verwendung dieses Geräts in der Nähe von Anlagen, die elektromagnetische
Störungen hervorrufen, kann zu instabilen bzw. ungenauen Messwerten führen.
Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen
Verletzungen führen.
Stromschlaggefahr:
• Bei an einer Komponente oder einem Stromkreis angeschlossenen Messleitungen
darf die Messfunktion nicht geändert werden.
• Die Zange darf nicht an einen Leiter angelegt werden, der eine Frequenz über
400 Hz führt. Bei Überschreitung dieser Frequenz können die Magnetschaltkreise
gefährliche Temperaturen entwickeln.
Nichtbeachten dieser Sicherheitsvorkehrungen kann zu Verletzungen oder Schäden
am Gerät führen.
Stromschlaggefahr:
• An diesem Gerät keine Reparaturen vornehmen. Es enthält keine Teile, die vom
Benutzer gewartet werden können.
• Das Gerät keinen extremen Temperaturen oder hoher Luftfeuchtigkeit aussetzen.
Siehe „Technische Daten“.
Nichtbeachten dieser Sicherheitsvorkehrungen kann zu Verletzungen oder Schäden
am Gerät führen.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
67
Bezeichnungen
1. Antenne für berührungslosen Nachweis eines elektrischen Feldes (EF)
2. Zangenmittenanzeige für optimale Genauigkeit; Polaritätsanzeige für Gleichstrom
3. Zur Auswahl einer Funktion oder zum Ausschalten des Geräts
4. LCD
5. Eingangsbuchsen – nur für Drehfeld und Motordrehung
6. Eingangsanschluss (+); Eingang L2 für Drehfeld und Motordrehung
7. Eingangsanschluss (– , Masse, Erde); Eingang L1 für Drehfeld und Motordrehung
8. Siehe Erläuterungen unter „Einsatz der Funktionen“.
9. Zangenhebel
10. Hände und Finger sind während des Betriebs unterhalb der Strichellinie zu halten.
11. Zange
12. Mittenanzeige für AmpTip™ Funktion
12
11
1
2
3
4
6
5
9
10
8
7
Symbole am Gerät
Warnhinweis – Bedienungsanleitung lesen
Warnung – Stromschlaggefahr
Erde
Doppelisolierung
AC (Wechselstrom)
DC (Gleichstrom)
Anlegen an bzw. Abnehmen von stromführenden Leitern mit gefährlichen
Spannungen ist zulässig.
68
Anzeigesymbole
1. Automatische Bereichswahl ist aktiviert.
2. Aufzeichnungs-Funktion ist aktiviert
3. Diode
4. Durchgang
5. Spitzen-Effektivwert-Modus ist aktiviert.
6. Drehfeld Netzstromversorgung
7. Motordrehung
8. 8.8.8.8 Numerische Anzeige
9. µ Mikro (10
-6
)
10. F Farad
11. A Ampere
12. V Volt
13. Hz Hertz (Frequenz in Taktzyklen pro Sekunde)
14. Ω Ohm
15. k Kilo (10
3
)
16. AmpTip™-Funktion ist aktiviert.
17. Funktion „Relative Zero“ (Relativer Nullpunkt) ist aktiviert.
18. Polaritätsanzeige
19. VFD Wechselstrommessung mit Filter zur genauen Messung bei
variablen Frequenzantrieben
20. AC-Messung ist ausgewählt.
21. + AC- und DC-Messung ist ausgewählt.
22. DC-Messung ist ausgewählt.
23. Niedriger Batteriestand
24. Halte-Funktion ist ausgewählt.
25. MAX Maximaler Messwert wird angezeigt.
26. MIN Minimaler Messwert wird angezeigt.
27. AVG Durchschnittswert wird angezeigt.
6-7
23-27
18
17
22
28
20
19
21
8
9-12
1
16 15 14 13
2 3 4 5
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
69
Einsatz der Funktionen
Alle Modelle
REC (AUFZEICHNUNG): Diese Taste kurz drücken, um den MAX/MIN/AVG-
Aufzeichnungsmodus zu aktivieren. und „MAX MIN AVG“ erscheinen dann auf der
Anzeige. Bei Aktualisierung des Minimal- bzw. Maximalwertes gibt das Messgerät ein
Tonsignal ab. Der Durchschnittswert wird über einen Zeitraum berechnet. Die Taste
kurz drücken, um die Messewerte für MAX, MIN und AVG nacheinander anzuzeigen.
Diese Taste eine Sekunde lang drücken, um den MAX/MIN/AVG-Aufzeichnungsmodus
zu aktivieren. Die Abschaltautomatik (APO) ist in diesem Modus automatisch
deaktiviert.
SELECT (AUSWÄHLEN): Kurz drücken, um zu den verschiedenen Funktionen,
Messarten oder Anzeigemodi umzuschalten. Die letzte verwendete Einstellung wird
zur Standardeinstellung, wenn diese Funktion erneut gewählt wird. Zur Änderung
der Standardeinstellung eine neue Einstellung wählen. Die Einstellung wird im
nichtflüchtigen Speicher gespeichert.
HOLD (HALTEN): Kurz drücken, um den aktuellen Messwert auf der Anzeige zu halten.
Nochmals drücken, um diesen Modus zu beenden.
Intelligente Abschaltautomatik (APO): Das Messgerät schaltet sich nach ungefähr
32 Minuten Inaktivität aus, um die Nutzungsdauer der Batterie zu verlängern. Die
aktive Messgerätefunktion wird wie folgt definiert: Auswahlschalter wird gedreht,
Tasten werden gedrückt; Messungen von über 8,5 % des Bereichs; nicht auf die
Überlast (OL) bezogene Messungen für Widerstand, Durchgang oder Diodenfunktion;
Messwerte ungleich null für die Hz-Funktion; Drehfeld-Segment in Bewegung. Um
das Messgerät nach einer automatischen Abschaltung wieder zu aktivieren, die Taste
SELECT (AUSWÄHLEN) kurz drücken oder den Wahlschalter auf OFF (AUS) drehen und
dann wieder einschalten. Den Drehschalter grundsätzlich auf OFF (AUS) drehen, wenn
das Messgerät nicht in Gebrauch ist.
Nur für CM-860, CM-960, CMH-600 und CMI-600
: Die Taste SELECT (AUSWÄHLEN) eine Sekunde lang drücken, um die LCD-
Hintergrundbeleuchtung ein- und auszuschalten. Die Hintergrundbeleuchtung schaltet
sich nach 32 Sekunden aus, um die Nutzungsdauer der Batterie zu verlängern.
∆: Die Taste eine Sekunde lang drücken, um zwischen den Modi Zero und Normal
umzuschalten. Im Zero-Modus wird der beim Drücken der Taste auf der LCD-Anzeige
angezeigte Wert als Offset-Wert festgelegt. Bei einer Änderung des Eingangswerts
wird die Verschiebung vom Istwert abgezogen. Dieser abgeänderte Wert erscheint auf
der LCD-Anzeige.
Hinweis: Betrieb, wenn Funktion DCA oder DC + ACA ausgewählt wird, wird die
magnetische Hysterese in der Zange ausgeglichen. Wenn der Wert für DCA oder DC
+ ACA vor der Messung nicht null ist, die Taste eine Sekunde lang drücken. Auf
der LCD-Anzeige wird „dc_0“ eingeblendet. Wenn diese Anzeige erlischt, ist das
Messgerät betriebsbereit. Wenn mehr als 5 A gemessen werden, ist dieser Modus
deaktiviert. Das Messgerät gibt drei Signaltöne ab, um darauf aufmerksam zu
machen.
Nur für CM-960, CMH-600 und CMI-600
PEAK-RMS (SPITZEN-EFFEKTIVWERT): Die Taste PEAK-RMS (SPITZEN-
EFFEKTIVWERT) eine Sekunde lang drücken, um den PEAK-RMS-Modus zur Erfassung
des Spitzenstroms bzw. der Spitzenspannung ab 80 ms Dauer zu aktivieren.
wird auf der Anzeige eingeblendet. Die Taste eine Sekunde lang drücken, um den
Modus PEAK-RMS (SPITZEN-EFFEKTIVWERT) zu verlassen. Die Abschaltautomatik
(APO) ist in diesem Modus automatisch deaktiviert.
70
Nur für CMH-600 und CMI-600
und : Falls gewünscht, die Taste REC (AUFZEICHNUNG) gedrückt halten und
dabei das Messgerät einschalten, um das akustische Signal zu aktivieren. Wenn
die Segmente eine Drehung im Uhrzeigersinn anzeigen, ertönt ein einzelner langer
Signalton pro Segmentzyklus. Wenn die Segmente eine Bewegung entgegen dem
Uhrzeigersinn anzeigen, ertönen drei kurze Signaltöne pro Segmentzyklus.
: Sicherstellen, dass der Motor von seiner Stromversorgung elektrisch
isoliert ist. Die Taste SELECT (AUSWÄHLEN) kurz drücken, um die Motorfunktion
auszuwählen. Das Messgerät entsprechend den Anweisungen in der „Tabelle
der Einstellungen“ in diesem Handbuch an den Motor anlegen. Den Motor im
Uhrzeigersinn drehen (Blickrichtung entlang der Motorwelle). Wenn das Messgerät
eine Drehung im Uhrzeigersinn anzeigt, sind die an L1, L2 und L3 des Messgeräts
angeschlossenen Motorleitungen T1, T2 bzw. T3. Wenn das Messgerät eine
Drehung entgegen dem Uhrzeigersinn anzeigt, zwei beliebige Anschlüsse
zwischen Messgerät und Motor vertauschen und erneut prüfen.
: Die Taste SELECT (AUSWÄHLEN) kurz drücken, um die Drehfeldfunktion
auszuwählen. Das Messgerät entsprechend den Anweisungen in der „Tabelle der
Einstellungen“ in diesem Handbuch an die Phasen anlegen. Wenn das Messgerät
eine Drehung im Uhrzeigersinn anzeigt, sind die an L1, L2 und L3 des Messgeräts
angeschlossenen Phasen L1, L2 bzw. L3. Wenn das Messgerät eine Drehung
entgegen dem Uhrzeigersinn anzeigt, zwei beliebige Anschlüsse zwischen
Messgerät und Phasen vertauschen und erneut prüfen.
Verwendung der Messleitungen
Stromschlaggefahr:
Die im Lieferumfang dieses Produkts enthaltenen Messleitungen entsprechen
den Sicherheitsstandards, die die freiliegende Länge der Sondenspitze für die
Messkategorien III und IV auf 4 mm beschränken. Zu diesen Messleitungen gehört
eine Kappe, die für Anwendungen der Messkategorie III bzw. IV aufgesetzt sein muss.
Das Nichtbeachten dieser Warnung kann zu schweren oder tödlichen Verletzungen
führen.
Für Anwendungen der Messkategorie III oder IV
muss die Kappe aufgesetzt sein.
Für Anwendungen der Messkategorie I oder II
kann sie jedoch abgenommen werden.
Einsatz der Funktionen (Fortsetzung)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
71
Wechselstrommessung
Wechselstrommessungen werden normalerweise als Effektivwerte (RMS,
quadratischer Mittelwert) angezeigt. Der Effektivwert entspricht dem Wert
einer Gleichstromwellenform, die dieselbe Stromleistung liefern würde, als
wenn sie die zeitlich-veränderliche Wellenform ersetzen würde. Die beiden
Wechselstrommessmethoden sind: den Mittelwert ermittelnde, auf den Effektivwert
kalibrierte Messung und Echteffektivwert-Messung.
Bei der Methode „den Mittelwert ermittelnde, auf den Effektivwert kalibrierte Messung“
wird der Mittelwert des Eingangssignals nach kompletter Gleichrichtung der Wellen mit
1,11 multipliziert und das Ergebnis angezeigt. Diese Methode ist genau, wenn es sich
bei dem Eingangsignal um eine reine Sinuswelle handelt.
Bei der Echteffektivwertmessmethode kommt zum Ablesen des echten Effektivwerts
ein innerer Schaltkreis zum Einsatz. Diese Methode ist im Rahmen der angegebenen
Crestfaktor-Beschränkungen genau, gleich, ob es sich bei dem Eingangssignal um eine
reine Sinus-, Rechteck-, Dreieck- oder Halbwelle bzw. ein Signal mit Oberschwingungen
handelt. Die Möglichkeit, den Echteffektivwert abzulesen, bietet vielseitigere
Messmöglichkeiten. Bei den Modellen CM-660, CM-860, CM-960, CMH-600 und
CMI-600 von Greenlee handelt es sich um Echteffektivwert-Messgeräte.
In der Tabelle „Wellenformen und Crestfaktoren“ sind einige typische
Wechselstromsignale und deren Effektivwerte angegeben.
Wellenformen und Crestfaktoren
Wellenform
Effektivwert 100 100 100 100
Durchschnittswert 90 100 87 64
Crestfaktor*
(x)
1,414 1 1,73 2
* Bei dem Crestfaktor handelt es sich um das Verhältnis des Spitzenwertes (auch
Scheitelwertes) zum Effektivwert und wird durch den griechischen Buchstaben x
dargestellt.
AC + DC Echteffektivwert
Mit AC + DC Echteffektivwert werden die beiden Wechselstrom- und
Gleichstromkomponenten bei der Messung mithilfe der folgenden Formel bestimmt:
Das Gerät reagiert ungeachtet der Wellenform fehlerfrei auf den gesamten Effektivwert.
Verzerrte Wellenformen mit vorhandenen DC-Komponenten und Oberschwingen können
Folgendes verursachen:
• Überhitzung von Transformatoren, Generatoren und Motoren
• Frühzeitige Auslösung von Schutzschaltern
• Durchbrennen von Sicherungen
• Überhitzung von Nullleitern aufgrund von auf dem Nullleiter vorhandenen
harmonischen Triplen
• Vibration der Stromschiene und der Elektroschalttafeln
Die Modelle CM-960 und CMI-600 können so eingestellt werden, dass sie entweder den
AC-Echteffektivwert oder AC- + DC-Echteffektivwert anzeigen.
72
AC-Bandbreite
Bei der AC-Bandbreite handelt es sich um den Frequenzbereich, in dem AC-Messungen
mit der angegebenen Genauigkeit vorgenommen werden können. Es ist die
Frequenzreaktion der AC-Funktionen – nicht die der Frequenzmessungsfunktionen.
Ein Messgerät kann den AC-Wert mit Frequenzspektren außerhalb seiner Bandbreite
nicht genau bestimmen. Komplexe Wellenformen, Rauschen und verzerrte
Wellenformen enthalten Frequenzkomponenten, die sehr viel höher sind als die
Fundamentalschwingung. Beispiel: hochfrequentes Rauschen auf einer 50/60
Hz-Freileitung.
Betrieb
Stromschlaggefahr:
Das Berühren von Stromkreisen kann zu schweren Verletzungen
oder zum Tod führen.
Bedienungsanweisung
1. Siehe „Tabelle der Einstellungen“. Den Wahlschalter auf die richtige Einstellung
drehen, (bei Aufforderung) SELECT (AUSWÄHLEN) drücken und dann die
Messleitungen am Messgerät anschließen.
2. Siehe „Typische Messungen“ für spezifische Messanleitungen.
3. Das Gerät an einem funktionierenden Stromkreis oder einer funktionsfähigen
Komponente testen.
• Wenn das Messgerät an einem funktionierenden Stromkreis nicht wie erwartet
funktioniert, die Batterien austauschen.
• Wenn das Messgerät anschließend immer noch nicht wie erwartet funktioniert,
unter der Rufnummer +1-815-397-7070 Kontakt mit dem technischen
Kundendienst von Greenlee aufnehmen.
4. Den Messwert von dem zu testenden Stromkreis oder der zu testenden Komponente
ablesen.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
73
Tabelle der Einstellungen
Zur Messung von …
den
Wahlschalter
auf dieses
Symbol
stellen …
Diese Symbole
erscheinen
dann in der
Anzeige …
Die rote
Messleitung
anschließen
an …
Die
schwarze
Messleitung
anschließen
an …
ALLE MODELLE
Spannung (AC)
V
+ COM
Spannung (DC)
V
+ COM
Strom, AmpTip™ (AC)
A
nicht zutr. nicht zutr.
Strom (AC)
A
nicht zutr. nicht zutr.
Durchgang
Ω
+ COM
Widerstand
Ω
+ COM
Diode
V
+ COM
Frequenz
Hz Hz
+ COM
Elektrisches Feld (EF)*
EF EF
nicht zutr. COM
Nur für CM-860, CM-960, CMH-600 und CMI-600
Kapazität**
µF
+ COM
Nur für CM-960 und CMI-600
Spannung (AC + DC) + COM
Strom, AmpTip™ (DC)
A
nicht zutr. nicht zutr.
Strom, AmpTip™
(AC + DC)
A
nicht zutr. nicht zutr.
Strom (DC)
A
nicht zutr. nicht zutr.
Strom (AC + DC)
A
nicht zutr. nicht zutr.
Nur für CMH-600 und CMI-600
Temperatur
Temp C oder F
***
Strom (µA DC)
µA
+ COM
Drehfeld† + COM
Motordrehung† + COM
* Die Oberseite der stationären Zangenbacke verwenden oder, für noch genauere
Messungen, eine Sonde im COM-Anschluss.
** Den Kondensator vor der Messung entladen. Weitere Informationen zu polarisierten
Kondensatoren sind unter „Typische Messungen“ zu finden.
*** Thermoelement + wird an + angeschlossen, Thermoelement – wird an COM
angeschlossen.
Die gelbe Leitung wird an L3 angeschlossen.
Betrieb (Fortsetzung)
74
Typische Messungen und Messgenauigkeit
Informationen zu den Betriebsbedingungen und zum Temperaturkoeffizienten sind im
Abschnitt „Technische Daten“ zu finden.
Die Messgenauigkeit ist wie folgt angegeben: ± (ein Prozentsatz des Messwerts + ein
fester Betrag) bei 23 °C ± 5 °C (73,4 °F ± 9 °F).
Bei nicht sinusförmigen Wellenformen muss die Frequenz innerhalb der angegebenen
Bandbreite liegen. Die Crestfaktoren sind, falls nicht anders angegeben, wie folgt:
• Crestfaktor < 2,5:1 bei Maßstab 1:1
• Crestfaktor < 5,0:1 bei Maßstab 1:2
Frequenz
Funktion
Empfindlichkeit
(Sinussignal-Effektivwert)*
Bereich
600 V 50 V 5,00 Hz ~ 999,9 Hz
60,0 A AmpTip™ 40 A 50,00 Hz ~ 400,0 Hz
60,00 A, 600,0 A 40 A 50,00 Hz ~ 400,0 Hz
* Die DC-Vorspannung muss <50 % des Sinussignal-Effektivwerts sein.
Genauigkeit des Frequenzbereichs
Anzeigebereich Messgenauigkeit
xx.xx ± (1,0% + 0,05 Hz)
xxx.x ± (1,0% + 0,5 Hz)
Spannungsmessung
VHz
EF
VFD
SELECT SELECT
VFD
Wechselspannung
Bereich
Messgenauigkeit
bei
50 Hz bis 60 Hz
600,0 ± (1,0% + 0,5 V)
Gleichspannung
Bereich Messgenauigkeit
600,0 ± (1,0% + 0,5 V)
Wechsel- und
Gleichspannung (nur für
(CM-960 und CMI-600)
Bereich
Messgenauigkeit
bei
Gleichspannung,
50 Hz bis 60 Hz
600,0 ± (1,2% + 0,7 V)
Eingangsimpedanz: 10 MΩ, 100 pF nominal
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
75
Strommessung
AmpTip™ Funktion
DC µA
μDC Strom (nur für CMH-600 und CMI-600)
Bereich Messgenauigkeit Bürdenspannung
200,0 μA ± (1,0% + 0,5 μA)
3,5 mV/μA
2000 μA ± (1,0% + 5 μA)
A
Hz
AmpTip™ Wechselstrom
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit bei
50 Hz bis 60 Hz**
60,00 A
< 0,20 A* Nicht angegeben
0,00 A bis 3,99 A ± (1,5% + 0,15 A)
4,00 A bis 60,00 A ± (1,5% + 0,05 A)
* Nur für CM-660, CM-860 und CMH-600.
** Nur für CM-960 und CMI-600: Der Induktionsfehler
für benachbarte stromführende Leiter ist <0,01 A/A.
AmpTip™ Gleichstrom
(nur für CM-960 und CMI-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit†
60,00 A
0,00 A bis 3,99 A ± (2,0% + 0,15 A)
4,00 A bis 60,00 A ± (2,0% + 0,05 A)
AmpTip™ Gleich- und Wechselstrom
(nur für CM-960 und CMI-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit
bei Gleichspannung,
50 Hz bis 60 Hz†
60,00 A
0,00 A bis 3,99 A ± (2,0% + 0,17 A)
4,00 A bis 60,00 A ± (2,0% + 0,07 A)
† Der Induktionsfehler für benachbarte stromführende Leiter ist <0,01 A/A.
Hinweis: Δ drücken, falls vor der Messung ein Wert angezeigt wird, der dann
als Offset-Wert abgezogen wird.
Typische Messungen und Messgenauigkeit
(Fortsetzung)
Flame Sensor
Control
Board
Pilot Flame
µA
Flammenwächter
Steuerplatine
Zündflamme
76
A
Hz
Wechselstrom (nur für CM-960 und CMI-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit bei
50 Hz bis 100 Hz*†
Messgenauigkeit bei
100 Hz bis 400 Hz*†
60,00 A
0,00 A bis 8,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
9,00 A bis 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A bis 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Maximaler Crestfaktor <2:1 bei Maßstab 1:1 und <4:1 bei Maßstab 1:2.
Wechselstrom (nur für CM-660, CM-860 und CMH-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit bei
50 Hz bis 100 Hz*†
Messgenauigkeit bei
100 Hz bis 400 Hz*†
60,00 A
0,00 A bis 0,19 A Nicht angegeben Nicht angegeben
0,20 A bis 5,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A)
6,00 A bis 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A)
600,0 A 60,0 A bis 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A)
* Bei allen Messungen, bei denen der Leiter nicht mittig in der Zange positioniert ist,
müssen 2,0 % aufgrund des Positionsfehlers zur Toleranz addiert werden.
Gleichstrom (nur für CM-960 und CMI-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit†
60,00 A
0,00 A bis 8,99 A ± (2,0% + 0,15 A)
9,00 A bis 60,00 A ± (2,0% + 0,05 A)
600,0 A 60,0 A bis 600,0 A ± (2,0% + 0,5 A)
Wechsel- und Gleichstrom (nur für CM-960 und CMI-600)
Bereich
Messgenauigkeits-
bereich
Messgenauigkeit bei
50 Hz bis 100 Hz†
Messgenauigkeit bei
100 Hz bis 400 Hz†
60,00 A
0,00 A bis 8,99 A ± (2,2% + 0,15 A) ± (2,7% + 0,17 A)
9,00 A bis 60,00 A ± (2,2% + 0,05 A) ± (2,7% + 0,07 A)
600,0 A 60,0 A bis 600,0 A ± (2,2% + 0,5 A) ± (2,7% + 0,7 A)
† Der Induktionsfehler für benachbarte stromführende Leiter ist <0,01 A/A.
Hinweis: Δ drücken, falls vor der Messung ein Wert angezeigt wird, der dann als Offset-
Wert abgezogenwird.
Typische Messungen und Messgenauigkeit
(Fortsetzung)
Strommessung
(Fortsetzung)
Zange für Wechsel-
und Gleichstrom
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
77
Ω
SELECT
Widerstandsmessung
SELECT
Durchgangsprüfung
Widerstand
Bereich Messgenauigkeit
600,0 Ω ± (1,0% + 0,5 Ω)
6,000 kΩ ± (1,0% + 0,005 kΩ)
60,00 kΩ ± (1,0% + 0,05 kΩ)
Leerlaufspannung: 1,0 V DC
Durchgang
Signal-Schwellenwert:
Zwischen 10 Ω und 250 Ω
Ansprechzeit: ca. 32 ms
Kapazitätsmessung
Kapazität (nur für CM-860,
CM-960, CMH-600 und CMI-600)
Bereich Messgenauigkeit*
200,0 μF ± (2,0% + 0,4 μF)
2500 μF ± (2,0% + 4 μF)
* Für Schichtkondensatoren
(Kondensatoren mit vernachlässigbarer
dielektrischer Absorption)
Hinweis: Bei polarisierten Kondensatoren die
rote Sonde an den positiven Anschluss und die
schwarze Sonde an den negativen Anschluss
des Kondensators anschließen.
Typische Messungen und Messgenauigkeit
(Fortsetzung)
78
Sperrvor-
spannung
Durchlass-
spannung
Diodenmessung
Diodentest
Messbereich: 2000 V
Messgenauigkeit: ± (1,5 % + 0,005 V)
Prüfstrom (typisch): 0,3 mA
Leerlaufspannung (typisch): <3,5 V DC
Temperatur
SELECT
Temperatur (nur für CMH-600 und CMI-600)
Bereich Messgenauigkeit*
-40,0 °C ~ 99,9 °C ± (1,0% + 0,8 °C)
100 °C ~ 400 °C ± (1,0% + 1 °C)
-40,0 °F ~ 211,8 °F ± (1,0% + 1,5 °F)
212 °F ~ 752 °F ± (1,0% + 2 °F)
* Messgenauigkeit des Thermoelements vom
TypK nicht aufgeführt. Das im Lieferumfang des
Messgeräts enthaltene Thermoelement entspricht
der Norm JIS C 1602 1981.
SELECT
Typische Messungen und Messgenauigkeit
(Fortsetzung)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
79
A
10 mm
(0.4")
B
SELECT
Elektrisches Feld
Hinweis: CM-660
und CM-860 haben
eine dedizierte
Schalterposition.
A – Kontaktlos ODER
B – Kontakt, Präzisionsmessung
Berührungsloser Nachweis eines
elektrischen Feldes (EF)
Typische
Spannung
Bereich bei
50 Hz bis 60 Hz
LCD-
Anzeige
20 V 10 V ~ 36 V -
55 V 23 V ~ 83 V - -
110 V 59 V ~ 165 V - - -
220 V 124 V ~ 330 V - - - -
440 V 250 V ~ 600 V - - - - -
Drehfeld Motordrehung
Typische Messungen und Messgenauigkeit
(Fortsetzung)
Clockwise Counterclockwise
SELECT
Entgegen dem
Uhrzeigersinn
Im
Uhrzeigersinn
80
Technische Daten
Anzeige: LCD, 3 5/6 Stellen mit maximal 6000 Punkten
Polarität: Automatisch
Aktualisierungsrate: 5 pro Sekunde, Nennwert
Betriebsbedingungen:
0 °C bis 31 (32 °F bis 88 °F), 0 % bis 80 % relative Luftfeuchtigkeit
31 °C bis 40 (88°F bis 40,00 ), relative Luftfeuchtigkeit verringert sich linear
von 80 % auf 50 %
Verschmutzungsgrad: 2
Nur in Innenräumen verwenden
Höhe über NN: Betrieb unterhalb 2000 m (6500 ft)
Lagertemperatur: -20 °C bis 60 °C, relative Luftfeuchtigkeit <80 %,
mit entnommenen Batterien
Temperaturkoeffizient: Nennwert 0,15 x (Genauigkeit) pro Grad C unter 18 °C von 0 °C
bis 18 °C (32 °F bis 64,4 °F) und über 28 °C von 28 °C bis 40 (82,4 °F bis 104 °F)
oder anderweitig angegeben
Messung: Echteffektivwert
EMV:
Entspricht EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11)
In einem RF-Feld von 1 V/m bei Frequenzen von 405 MHz,
Modi DCA und DC+AC A (CM-960 und CMI-960):
Messgenauigkeit gesamt: angegebene Genauigkeit +20 Stellen
In einem RF-Feld von 1 V/m, Widerstandsmodi (alle Modelle) und Modus DC µA
(CMH-600 und CMI-600):
Messgenauigkeit gesamt: angegebene Genauigkeit +25 Stellen
In einem RF-Feld von 3 V/m, alle anderen Modi sowie oben nicht angegebenen
Modelle: Messgenauigkeit gesamt: angegebene Genauigkeit +20 Stellen
Sicherheitsvorkehrungen: Doppelisolierung gemäß UL/IEC/EN61010-1 Version 3, IEC/
EN61010-2-033 Version 1, CAN/CSA C22.2 Nr. 61010-1 Version 3,
IEC/EN61010-2-032 Version 2 und IEC/EN61010-031 Version 1.1 nach CAT III 600V
und CAT IV 300V AC und DC
Überlastschutz:
Zange:
Strom- mit Frequenzfunktion: 600 A DC/AC Effektivwert bei ≤400 Hz
Eingänge:
Spannungs- und Drehfeld-Funktion: 660 V DC/920 V AC Effektivwert
Alle anderen Modi und Funktionen: 600 V DC/AC Effektivwert
Stoßspannungsschutz: 6,0 kV (Stoßspannung von 1,2/50 μs)
Stromversorgung: Zwei 1,5-V-AAA-Batterien (NEDA 24A oder IEC LR03)
Niedriger Batteriestand:
Kapazitäts- und Frequenzfunktion: Ca. 2,85 V
Alle anderen Funktionen: Ca. 2,5 V
Stromaufnahme:
CM-960 und CMI-600: Normalerweise 13 mA
CM-660, CM-860 und CMH-600: Normalerweise 4,3 mA
Wartezeit für Abschaltautomatik (APO): 32 Minuten Inaktivität
APO-Stromaufnahme: 5 μA typischer Wert
Abmessungen:
CM-960 und CMI-600: 222 mm x 76 mm x 37 mm (8,7” x 3,0” x 1,4”)
CM-660, CM-860 und CMH-600: 217 mm x 76 mm x 37 mm (8,5” x 3,0” x 1,4”)
Zangenöffnung und Leiterdurchmesser: Max. 30 mm (1,18”)
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
81
Messkategorien
Diese Definitionen stammen aus den internationalen Sicherheitsnormen für Isolierungen
– abgestimmt auf die Anwendbarkeit bei Mess-, Steuer- und Laborgeräten. Genauere
Beschreibungen dieser Messkategorien sind in den beiden folgenden Veröffentlichungen
der International Electrotechnical Commission zu finden: IEC 61010-1 oder IEC 60664.
Messkategorie II
Lokalebene. Haushaltgeräte, tragbare Geräte und die Stromnetze, an denen sie
angeschlossen sind. Dazu gehören beispielsweise Lampen, Fernsehgeräte und lange
Abzweigkreise.
Messkategorie III
Verteilungsebene. Fest installierte Maschinen und die Netze, an denen sie
fest angeschlossen sind. Dazu gehören beispielsweise Förderanlagen und die
Hauptstromunterbrechungs-Schalttafeln der elektrischen Anlage eines Gebäudes.
Messkategorie IV
Primärversorgungsebene. Freileitungen und andere Kabelsysteme. Dazu gehören
beispielsweise Kabel, Elektrizitätszähler, Transformatoren und sonstige Anlagen im
Freien, die der Stromversorgungsgesellschaft gehören.
Konformitätserklärung
Greenlee Tools, Inc. ist für seine Qualitätsverwaltungssysteme gemäß ISO 9001:2008
zertifiziert.
Das gelieferte Gerät wurde mit Betriebsmitteln überprüft bzw. kalibriert, die zum
National Institute for Standards and Technology (NIST) rückführbar sind.
82
Wartung
Stromschlaggefahr:
Vor dem Öffnen des Gehäuses die Messleitungen vom Stromkreis entfernen und das
Gerät ausschalten.
Das Nichtbeachten dieser Warnung könnte zu schweren oder tödlichen Verletzungen
führen.
Auswechseln der Batterien
1. Das Gerät vom Netz trennen.
Das Gerät AUSSCHALTEN.
2. Die beiden Schrauben aus
dem Batteriefachdeckel
herausdrehen und den Deckel
abnehmen.
3. Beim Auswechseln der
Batterien die Polarität der
Batterien beachten.
Reinigen und Lagerung
Das Gehäuse regelmäßig mit einem
feuchten Tuch und einem milden
Reinigungsmittel abwischen. Keine
Scheuer- oder Lösungsmittel
verwenden.
Soll das Messgerät länger als
60Tage nicht verwendet werden,
die Batterien herausnehmen und
getrennt vom Gerät aufbewahren.
CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600
83
Lifetime Limited Warranty
Greenlee Tools, Inc. warrants to the original purchaser of these goods for use that
these products will be free from defects in workmanship and material for their
useful life, excepting normal wear and abuse. This warranty is subject to the same
terms and conditions contained in Greenlee Tools, Inc.’s standard one-year limited
warranty.
For all Test Instrument repairs, contact Customer Service at 800-435-0786 and
request a ReturnAuthorization.
For items not covered under warranty (such as items dropped, abused, etc.), a
repair cost quote is available uponrequest.
Note: Prior to returning any test instrument, please check replaceable batteries or
make sure the battery is at fullcharge.
Garantía limitada válida durante la vida útil del producto
Greenlee Tools, Inc. le garantiza al comprador original de estos bienes de uso,
que los mismos estarán libres de defectos de materiales y fabricación durante su
vida útil, excepto en el caso de que sean maltratados o hayan sufrido el deterioro
normal. Esta garantía está sujeta a los mismos términos y condiciones de la
garantía estándar limitada válida por un año, otorgada por Greenlee Tools, Inc.
Para reparaciones de todo instrumento de verificación, comuníquese con el
Departamento de Servicio al Cliente al 800-435-0786 y solicite una autorización de
devolución.
Puede obtener, previa solicitud, una cotización de precios de reparación para
aquellos artículos que no están cubiertos bajo esta garantía (los que se han dejado
caer o han sido maltratados).
Aviso: Antes de devolver un instrumento de verificación, revise si las baterías están
bajas y es necesario reemplazarlas.
Garantie à vie limitée
La société Greenlee Tools, Inc. garantit à l’acheteur d’origine de ces produits que
ces derniers ne comportent aucun défaut d’exécution ou de matériau pour la durée
de leur vie utile, sauf l’usure normale. Cette garantie est assujettie aux mêmes
conditions que celles contenues dans les modalités et conditions de la garantie
limitée standard d’un an de Greenlee Tools, Inc.
Pour toutes les réparations d’instruments de mesure, appeler le service après vente
au 800 435-0786 et demander une autorisation de retour.
Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil
tombe, s’il est soumis à un usage abusif, etc.), une soumission pour le prix de
réparation sera présentée sur demande.
Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier les piles
remplaçables ou vous assurer que la batterie est complètement chargée.
Lebenslange beschränkte Garantie
Greenlee Tools, Inc. garantiert dem Erstkäufer dieser Produkte, dass sie unter
Ausschluss von normalem Verschleiß oder Missbrauch für den Zeitraum ihrer
Nutzungsdauer frei von Bearbeitungs- und Materialfehlern sind. Diese Garantie
unterliegt denselben Bedingungen, die auch für die standardmäßige beschränkte
Einjahresgarantie von Greenlee Tools, Inc. gelten.
Bei allen Reparaturen von Messgeräten muss eine Rücksendegenehmigung bei der
Kundendienstabteilung unter +1-800-435-0786 angefordert werden.
Bei Geräten ohne Garantieschutz (z.B. heruntergefallene oder missbrauchte
Produkte) kann auf Anfrage ein Kostenvoranschlag für die Reparatur erstellt werden.
Hinweis: Bitte prüfen Sie vor dem Einsenden des Geräts die austauschbaren
Batterien bzw. stellen Sie sicher, dass die Batterie vollständig geladen ist.
4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070
An ISO 9001 Company • ©2019 Greenlee Tools, Inc.
USA
Tel: 800-435-0786
Fax: 800-451-2632
Canada
Tel: 800-435-0786
Fax: 800-524-2853
International
Tel: +1-815-397-7070
Fax: +1-815-397-9247
www.greenlee.com
Register this product at www.greenlee.com
Registre este producto en www.greenlee.com
Enregistrez votre produit en ligne, www.greenlee.com
Dieses Produkt kann unter www.greenlee.com registriert werden

Transcripción de documentos

INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D’INSTRUCTIONS BEDIENUNGSANLEITUNG CM-660 CM-860 CM-960 CMH-600 CMI-600 Español.............23 Français............43 Deutsch.............63 Clamp Meters Medidores con pinza Contrôleurs à pince Zangenmessgeräte Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Lea y entienda todas las instrucciones y la información sobre seguridad que aparecen en este manual, antes de manejar estas herramientas o darles mantenimiento. Lire attentivement et bien comprendre toutes les ­instructions et les informations sur la sécurité de ce manuel avant d’utiliser ou de procéder à l’entretien de cet outil. Vor Bedienung oder Wartung dieses Messgerätes bitte alle Anweisungen und Sicherheitsinformationen in diesem Handbuch genau durchlesen und beachten. 52066382 REV 2 © 2019 Greenlee Tools, Inc. 10/19 Description The Greenlee CM-660, CM-860, CM-960, CMH-600, and CMI-600 Clamp Meters are hand-held testing devices with the following measurement capabilities: AC and DC voltage, AC current, AC current AmpTip™, frequency, non-contact electric field (EF) detection, and resistance. They also check diodes and verify continuity. These meters are designed to be placed on or removed from insulated or uninsulated conductors. Additional functionality specific to each model includes: Function CMI-600 CM-960 CMH-600 CM-860 AC + DC Voltage • • DC Current AmpTip™ • • DC + AC Current AmpTip™ • • DC Current • • µDC Current • • Temperature (K-style thermocouple) • • Motor Rotation • • Phase Rotation • Peak RMS Capture • • • Capacitance • • • • Backlight • • • • Zero Mode • • • • • Other capabilities include: • Hold Mode to capture the present LCD value • Record Minimum, Maximum, or Average Mode • Intelligent Auto Power Off • Automatic ranging Safety Safety is essential in the use and maintenance of Greenlee tools and equipment. This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool. Observe all of the safety information provided. Purpose of This Manual This instruction manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee CM-660, CM-860, CM-960, CMH-600, and CMI-600 Clamp Meters. Keep this manual available to all personnel. Replacement manuals are available upon request at no charge at www.greenlee.com. 2 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Important Safety Information SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message after the signal word provides information for preventing or avoiding the hazard. Immediate hazards which, if not avoided, WILL result in severe injury or death. Hazards which, if not avoided, COULD result in severe injury or death. Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage. Read and understand this material before operating or servicing this ­equipment. Failure to understand how to safely operate this tool could result in an accident causing serious injury or death. Electric shock hazard: Contact with live circuits could result in severe injury or death. Do not discard this product or throw away! For recycling information, go to www.greenlee.com. All specifications are nominal and may change as design improvements occur. Greenlee Tools, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. ® Registered: The color green for electrical test instruments is a registered trademark of Tools, Innovations Inc. AmpTip is a trademark of BTC. KEEP THIS MANUAL 3 Important Safety Information Electric shock and fire hazard: • Do not expose this unit to rain or moisture. • Do not use the unit if it is wet or damaged. • Clamp meter, test leads or any other clamp accessory, when used to make a measurement, create a System. The System is rated for CAT III 600 V or CAT IV 300 V when using the test leads or accessories provided with the meter. The System CAT and voltage rating is limited by the lowest rated component in the System when using test leads or accessories not provided with the meter. • Inspect the test leads or accessory before use. They must be clean and dry, and the insulation must be in good condition. Do not use the test lead if the contrasting inner layer of insulation is visible. • Use this unit for the manufacturer’s intended purpose only, as described in this manual. Any other use can impair the protection provided by the unit. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: • Do not apply more than the rated voltage between any two input terminals, or between any input terminal and earth ground. • Keep hands and fingers below the barriers on the test leads and the clamp meter body. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: • Do not operate with the case open. • Before opening the case, remove the test leads from the circuit and shut off the unit. Failure to observe these warnings could result in severe injury or death. 4 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Important Safety Information Electric shock hazard: • Unless measuring voltage, current, or frequency, shut off and lock out power. Make sure that all capacitors are discharged. Voltage must not be present. • Set the selector and connect the test leads so that they correspond to the intended measurement. Incorrect settings or connections can result in incorrect measurements or damage to the unit. • Using this unit near equipment that generates electromagnetic interference can result in unstable or inaccurate readings. Failure to observe these warnings could result in severe injury or death. Electric shock hazard: • Do not change the measurement function while the test leads are connected to a component or circuit. • Do not clamp the jaw around a conductor carrying a frequency greater than 400 Hz. The magnetic circuitry may reach a hazardous temperature if this frequency is exceeded. Failure to observe these precautions may result in injury and can damage the unit. Electric shock hazard: • Do not attempt to repair this unit. It contains no user-serviceable parts. • Do not expose the unit to extremes in temperature or high humidity. Refer to “Specifications.” Failure to observe these precautions may result in injury and can damage the unit. 5 Identification 1. Antenna for non-contact EF detection 2. Jaw center indicator for best current accuracy; polarity indicator for DC amps 3. Selects a function or turns power off 4. LCD 5. Input jack for phase and motor rotation functions only 6. Positive input terminal; L2 input for motor and phase rotation 7. Negative, common, or ground input terminal; L1 input for motor and phase rotation 8. Refer to explanation under “Using the Features.” 9. Jaw lever 10. Keep hand or fingers below the dashed line during operation. 11. Jaw 12. Center indicator for AmpTip™ function 12 1 11 2 10 9 3 4 8 7 5 6 Symbols on the Unit Warning—Read the instruction manual Warning—Risk of electric shock Earth ground Double insulation AC (alternating current) DC (direct current) Application around or removal from hazardous live conductors is permitted. 6 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Display Icons 1. 2. 3. 4. 5. 6. 7. 8. 8.8.8.8 9. µ 10. F 11. A 12. V 13. Hz 14. Ω 15. k 16. 17. ∆ 18. – 19. VFD 20. 21. + 22. 23. 24. 25. MAX 26. MIN 27. AVG Automatic ranging is enabled. Record function is enabled. Diode Continuity PEAK-RMS mode is enabled. Phase rotation main supply Motor rotation Numeric display Micro (10-6) Farad Ampere Volt Hertz (frequency in cycles per second) Ohm Kilo (103) AmpTip™ function is enabled. Relative zero function is enabled. Polarity indicator AC measurement with filter for accuracy on variable frequency drives AC measurement is selected. AC + DC measurement is selected. DC measurement is selected. Low battery Hold function is selected. Maximum value being displayed Minimum value being displayed Average value being displayed 1 2 3 4 5 28 21 19 23-27 22 6-7 20 8 18 17 9-12 16 15 14 13 7 Using the Features All Models • REC: Press momentarily to activate MAX/MIN/AVG recording mode. and “MAX MIN AVG” appear on the display. The meter beeps when new maximum or minimum reading is updated. The average reading is calculated over time. Press the button momentarily to read the MAX, MIN and AVG readings in sequence. Press the button for 1 second to exit MAX/MIN/AVG recording mode. APO is disabled automatically in this mode. • SELECT: Press momentarily to toggle between functions, measurement modes, or display modes. The last used setting becomes the default when that function is selected again. To change the default, select a new setting. The setting will be stored in nonvolatile memory. • HOLD: Press momentarily to hold the present value on the display. Press again to exit this mode. • Intelligent Auto Power Off (APO): The meter automatically turns off after approximately 32 minutes of inactivity to extend battery life. Active meter function is specified as: selector switch is rotated or pushbuttons are pressed; readings above 8.5% of the range; non-OL readings for resistance, continuity, or diode function; non-zero readings for Hz function; phase rotation segment moving. To wake up the meter from Auto Power Off, press the SELECT button momentarily and release or turn the rotary switch OFF and then back on. Always turn the rotary switch to the OFF position when the meter is not in use. CM-860, CM-960, CMH-600, and CMI-600 Only : Press the SELECT button for 1 second to toggle the LCD backlight. The backlight automatically turns off after 32 seconds to extend battery life. • ∆: Press the ∆ button for 1 second to toggle between zero and normal mode. In zero mode the value on the LCD when the button is pressed becomes the offset. As the input value changes, the offset is subtracted from the actual value. This modified value is shown on the LCD. Note: ∆ operation when DCA or DC + ACA functions are selected offsets any magnetic hysteresis in the jaw. If DCA or DC + ACA reading before measuring is not zero, press the ∆ button for 1 second. The LCD will display “dc_0”. When this clears, the meter is ready for operation. When measuring more than 5 A, this mode is disabled. As an indication, the meter will beep three times. • CM-960, CMH-600, and CMI-600 Only • PEAK-RMS: Press the PEAK-RMS button for 1 second to activate PEAK-RMS mode to capture peak current or voltage in duration as short as 80 ms. appears on the display. Press the button for 1 second to exit PEAK-RMS mode. APO is disabled automatically in this mode. CMH-600 and CMI-600 Only • 8 and : If desired, press and hold the REC button while turning the meter ON to enable the Beeper feature. If the segments indicate a clockwise movement, the beeper sounds a single long beep per segment cycle. If the segments indicate a counterclockwise movement, the beeper sounds three short beeps per segment cycle. • : Ensure the motor is electrically isolated from its power source. Press the SELECT button momentarily to select Motor function. Connect the meter to the motor as described in the “Settings Table” section of this manual. From the perspective of looking down the shaft of the motor, spin it clockwise. If the meter indicates a clockwise movement, the motor leads connected to L1, L2, and L3 of the meter are T1, T2, and T3, respectively. If the meter indicates a counterclockwise movement, swap any two connects between the meter and motor. Then retest. • : Press the SELECT button momentarily to select Phase function. Connect the meter to the phases as described in the “Settings Table” section of this manual. If the meter indicates a clockwise movement, the phases connected to L1, L2, and L3 of the meter are L1, L2, and L3, respectively. If the meter indicates a counterclockwise movement, swap any two connects between the meter and phases. Then retest. CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Using the Test Leads Electric shock hazard: The test leads supplied with this product comply with safety standards that limit the exposed length of the probe tip to 4 mm for measurement categories III and IV. These test leads include a cap that must be in place when used in measurement category III or IV applications. Failure to observe this warning could result in severe injury or death. Cap must be in place for measurement category III or IV applications. Cap can be removed for measurement category I or II applications. 9 AC Measurement AC measurements are usually displayed as RMS (root mean square) values. The RMS value is equal to the value of a DC waveform, which would deliver the same power if it replaced the time-varying waveform. Two AC measurement methods are average-responding RMS calibrated and true RMS-reading. The average-responding RMS calibrated method takes the average value of the input signal after full wave rectification, multiplies it by 1.11, and displays the result. This method is accurate if the input signal is a pure sine wave. The true RMS-reading method uses internal circuitry to read the true RMS value. This method is accurate, within the specified crest factor limitations, whether the input signal is a pure sine wave, square wave, triangle wave, half wave, or signal with harmonics. The ability to read true RMS provides much more measurement versatility. The Greenlee CM-660, CM-860, CM-960, CMH-600, and CMI-600 are true RMS meters. The Waveforms and Crest Factors table shows some typical AC signals and their RMS values. Waveforms and Crest Factors Waveform RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor* (x) 1.414 1 1.73 2 * The crest factor is the ratio of the peak value to the RMS value; it is represented by the Greek letter x. AC + DC True RMS AC + DC true RMS calculates both of the AC and DC components given by the expression when making measurements and responds accurately to the total effective RMS value regardless of the waveform. Distorted waveforms with the presence of DC components and harmonics may cause: • Transformers, generators, and motors to overheat • Circuit breakers to trip prematurely • Fuses to blow • Neutrals to overheat due to the triplen harmonics present on the neutral • Bus bars and electrical panels to vibrate CM-960 and CMI-600 can be set to display AC true RMS or AC + DC true RMS. 10 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 AC Bandwidth AC bandwidth is the range of frequencies over which AC measurements can be made within the specified accuracy. It is the frequency response of the AC functions—not of the frequency measurement functions. A meter cannot accurately measure the AC value with frequency spectrums outside its bandwidth. Complex waveforms, noise, and distorted waveforms contain frequency components that are much higher than the fundamental; for example, high frequency noise on a 50/60 Hz power line. Operation Electric shock hazard: Contact with live circuits could result in severe injury or death. Operating Procedure 1. Refer to the “Settings Table.” Set the selector to the proper setting, press SELECT (when instructed to do so), and connect the test leads to the meter. 2. Refer to “Typical Measurements” for specific measurement instructions. 3. Test the unit on a known functioning circuit or component. • If the unit does not function as expected on a known functioning circuit, replace the batteries. • If the unit still does not function as expected, call Greenlee for technical assistance at 800-435-0786. 4. Take the reading from the circuit or component to be tested. 11 Operation (cont’d) Settings Table To measure this value … Set the These icons Connect Connect selector appear on the the red the black to this display … lead to … lead to … symbol … ALL MODELS Voltage (AC) V + COM Voltage (DC) V + COM Current, AmpTip™ (AC) A N/A N/A Current (AC) A N/A N/A + COM + COM + COM + COM N/A COM Ω Continuity Resistance Ω kΩ V Diode Frequency Electric Field (EF)* Hz EF Hz EF CM-860, CM-960, CMH-600, and CMI-600 Only µF Capacitance** + COM + COM CM-960 and CMI-600 Only Voltage (AC + DC) Current, AmpTip™ (DC) A N/A N/A Current, AmpTip™ (AC + DC) A N/A N/A Current (DC) A N/A N/A Current (AC + DC) A N/A N/A CMH-600 and CMI-600 Only Temperature Current (µDC) Temp C or F µA *** + COM Phase Rotation† + COM Motor Rotation† + COM * Use the top side of the stationary jaw, or for more precise measurements use a probe in the COM terminal. ** Discharge capacitor before measurement. Refer to “Typical Measurements” regarding polarized capacitors. *** Thermocouple + connects to +, thermocouple – connects to COM. † Yellow lead connects to L3. 12 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typical Measurements and Accuracy Refer to the “Specifications” section for operating conditions and temperature coefficient. Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F). Frequency must be within the specified bandwidth for non-sinusoidal waveforms. Crest factors, unless otherwise specified, are as follows: • Crest factor < 2.5:1 at full scale • Crest factor < 5.0:1 at half scale Frequency Function 600 V 60.0 A AmpTip™ 60.00 A, 600.0 A Sensitivity (Sine RMS)* 50 V 40 A 40 A Range 5.00 Hz ~ 999.9 Hz 50.00 Hz ~ 400.0 Hz 50.00 Hz ~ 400.0 Hz * DC bias must be less than 50% of the Sine RMS value. Accuracy of Frequency Range Display Range xx.xx xxx.x Accuracy ± (1.0% + 0.05 Hz) ± (1.0% + 0.5 Hz) Voltage Measurement EF Hz V VFD VFD SELECT AC Voltage Range Accuracy at 50 Hz to 60 Hz 600.0 ± (1.0% + 0.5 V) SELECT AC + DC Voltage (CM-960, CMI-600 only) DC Voltage Range Accuracy 600.0 ± (1.0% + 0.5 V) Range Accuracy at DC, 50 Hz to 60 Hz 600.0 ± (1.2% + 0.7 V) Input Impedance: 10 MΩ, 100 pF nominal 13 Typical Measurements and Accuracy (cont’d) Current Measurement µA DC Current Flame Sensor µA Pilot Flame Control Board μDC Current (CMH-600 and CMI-600 only) Range 200.0 μA 2000 μA AmpTip™ Function Accuracy ± (1.0% + 0.5 μA) ± (1.0% + 5 μA) Burden Voltage 3.5 mV/μA AmpTip™ AC Current Range Accuracy Range < 0.20 A* 60.00 A 0.00 A to 3.99 A 4.00 A to 60.00 A Accuracy at 50 Hz to 60 Hz** unspecified ± (1.5% + 0.15 A) ± (1.5% + 0.05 A) * For CM-660, CM-860, and CMH-600 only. ** For CM-960 and CMI-600 only, induced error for adjacent current carrying conductors is < 0.01 A/A. Hz A AmpTip™ DC Current (CM-960 and CMI-600 only) Range Accuracy Range 0.00 A to 3.99 A 60.00 A 4.00 A to 60.00 A Accuracy† ± (2.0% + 0.15 A) ± (2.0% + 0.05 A) AmpTip™ DC + AC Current (CM-960 and CMI-600 only) Range 60.00 A Accuracy Range 0.00 A to 3.99 A 4.00 A to 60.00 A Accuracy at DC, 50 Hz to 60 Hz† ± (2.0% + 0.17 A) ± (2.0% + 0.07 A) † Induced error for adjacent current carrying conductors is < 0.01 A/A. Note: Use Δ if there is an offset before the measurement is taken. 14 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typical Measurements and Accuracy (cont’d) Current Measurement (cont’d) AC and DC Clamp Hz A AC Current (CM-960 and CMI-600 only) Range 60.00 A 600.0 A Accuracy Range 0.00 A to 8.99 A 9.00 A to 60.00 A 60.0 A to 600.0 A Accuracy at 50 Hz to 100 Hz*† ± (1.8% + 0.15 A) ± (1.8% + 0.05 A) ± (1.8% + 0.5 A) Accuracy at 100 Hz to 400 Hz*† ± (2.0% + 0.15 A) ± (2.0% + 0.05 A) ± (2.0% + 0.5 A) * Maximum crest factor < 2:1 at full scale and < 4:1 at half scale. AC Current (CM-660, CM-860, and CMH-600 only) Accuracy at Range Accuracy Range 50 Hz to 100 Hz*† 0.00 A to 0.19 A unspecified 60.00 A 0.20 A to 5.99 A ± (1.8% + 0.15 A) 6.00 A to 60.00 A ± (1.8% + 0.05 A) 600.0 A 60.0 A to 600.0 A ± (1.8% + 0.5 A) Accuracy at 100 Hz to 400 Hz*† unspecified ± (2.0% + 0.15 A) ± (2.0% + 0.05 A) ± (2.0% + 0.5 A) * For any measurement, when the conductor is not positioned on the center of the jaws, add 2.0% to the accuracy for position error. DC Current (CM-960 and CMI-600 only) Range Accuracy Range 0.00 A to 8.99 A 60.00 A 9.00 A to 60.00 A 600.0 A 60.0 A to 600.0 A AC + DC Current (CM-960 and CMI-600 only) Accuracy at Range Accuracy Range 50 Hz to 100 Hz† 0.00 A to 8.99 A ± (2.2% + 0.15 A) 60.00 A 9.00 A to 60.00 A ± (2.2% + 0.05 A) 600.0 A 60.0 A to 600.0 A ± (2.2% + 0.5 A) Accuracy† ± (2.0% + 0.15 A) ± (2.0% + 0.05 A) ± (2.0% + 0.5 A) Accuracy at 100 Hz to 400 Hz† ± (2.7% + 0.17 A) ± (2.7% + 0.07 A) ± (2.7% + 0.7 A) † Induced error for adjacent current carrying conductors is < 0.01 A/A. Note: Use Δ if there is an offset before the measurement is taken. 15 Typical Measurements and Accuracy (cont’d) Resistance Measurement Resistance Range 600.0 Ω 6.000 kΩ 60.00 kΩ Ω Accuracy ± (1.0% + 0.5 Ω) ± (1.0% + 0.005 kΩ) ± (1.0% + 0.05 kΩ) Open Circuit Voltage: 1.0 VDC SELECT Continuity Check Continuity Tone Threshold: Between 10 Ω and 250 Ω Response Time: Approximately 32 ms SELECT Capacitance Measurement Capacitance (CM-860, CM-960, CMH-600, and CMI-600 only) Range 200.0 μF 2500 μF Accuracy* ± (2.0% + 0.4 μF) ± (2.0% + 4 μF) * For film capacitors (capacitors with negligible dielectric absorption). Note: For polarized capacitors, attach red probe to positive terminal and black probe to negative terminal of capacitor. 16 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typical Measurements and Accuracy (cont’d) Diode Measurement Reverse Bias Forward Bias Diode Test Measuring Range: 2.000 V Accuracy: ± (1.5% + 0.005 V) Test Current (typical): 0.3 mA Open Circuit Voltage (typical): < 3.5 VDC SELECT Temperature Temperature (CMH-600 and CMI-600) Range -40.0 °C ~ 99.9 °C 100 °C ~ 400 °C -40.0 °F ~ 211.8 °F 212 °F ~ 752 °F Accuracy* ± (1.0% + 0.8 °C) ± (1.0% + 1 °C) ± (1.0% + 1.5 °F) ± (1.0% + 2 °F) * K-type thermocouple accuracy not included. Thermocouple supplied with meter meets standard JIS C 1602-1981. SELECT 17 Typical Measurements and Accuracy (cont’d) 10 mm (0.4") A Electric Field Note: CM-660 and CM-860 have a dedicated switch position. Non-contact EF Detection Typical Voltage 20 V 55 V 110 V 220 V 440 V Range at 50 Hz to 60 Hz 10 V ~ 36 V 23 V ~ 83 V 59 V ~ 165 V 124 V ~ 330 V 250 V ~ 600 V LCD Indication ----------- SELECT B A–Non-contact OR B–Contact, precision measurement Phase Rotation Motor Rotation SELECT Clockwise 18 Counterclockwise CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Specifications Display: LCD, 3-5/6 digits 6000 counts Polarity: Automatic Update Rate: 5 per second nominal Operating Conditions: 0 °C to 31 °C (32 °F to 88 °F), relative humidity 0% to 80% 31 °C to 40 °C (88 °F to 104 °F), relative humidity decreasing linearly from 80% to 50% Pollution Degree: 2 Indoor use only Altitude: Operating below 2000 m (6500 ft) Storage Temperature: -20 °C to 60 °C, relative humidity < 80%, with batteries removed Temperature Coefficient: Nominal 0.15 x (Accuracy) per °C below 18 °C from 0 °C to 18 °C (32 °F to 64.4 °F) and above 28 °C from 28 °C to 40 °C (82.4 °F to 104 °F) or otherwise specified Sensing: True RMS E.M.C.: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 1 V/m at a frequency of 405 MHz, DCA and DC+AC A mode (CM-960 and CMI-960): Total Accuracy = Specified Accuracy + 20 digits In an RF field of 1 V/m resistance mode (all models) and DC µA mode (CMH-600 and CMI-600): Total Accuracy = Specified Accuracy + 25 digits In an RF field of 3 V/m, all other modes and models not specified above: Total Accuracy = Specified Accuracy + 20 digits Safety: Double insulation per UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed. 1, CAN/CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 2 and IEC/EN61010-031 Ed. 1.1 to CAT III 600V and CAT IV 300V AC and DC Overload Protections: Jaws: Current with Frequency Function: 600 A DC/AC RMS at ≤ 400 Hz Terminals: Voltage and Phase Rotation Function: 660 V DC/920 V AC RMS All Other Modes and Functions: 600 V DC/AC RMS Transient Protection: 6.0 kV (1.2/50 μs surge) Power Supply: Two 1.5 V AAA batteries (NEDA 24A or IEC LR03) Low Battery: Capacitance and Frequency Function: Approximately 2.85 V All Other Functions: Approximately 2.5 V Current Consumption: CM-960 and CMI-600: Typically 13 mA CM-660, CM-860, and CMH-600: Typically 4.3 mA APO Timing: Idle for 32 minutes APO Consumption: 5 μA typical Dimensions: CM-960 and CMI-600: 222 mm x 76 mm x 37 mm (8.7" x 3.0" x 1.4") CM-660, CM-860, and CMH-600: 217 mm x 76 mm x 37 mm (8.5" x 3.0" x 1.4") Jaw Opening and Conductor Diameter: 30 mm max (1.18") 19 Measurement Categories These definitions were derived from the international safety standard for insulation ­coordination as it applies to measurement, control, and laboratory equipment. These measurement categories are explained in more detail by the International Electrotechnical Commission; refer to either of their p­ ublications: IEC 61010-1 or IEC 60664. Measurement Category II Local level. Appliances, portable equipment, and the circuits they are plugged into. Some examples include light fixtures, televisions, and long branch circuits. Measurement Category III Distribution level. Permanently installed machines and the circuits they are hard-wired to. Some examples include conveyor systems and the main circuit breaker panels of a building’s electrical system. Measurement Category IV Primary supply level. Overhead lines and other cable systems. Some examples include cables, meters, transformers, and other exterior equipment owned by the power utility. Statement of Conformity Greenlee Tools, Inc. is certified in accordance with ISO 9001 (2000) for our Quality Management Systems. The instrument enclosed has been checked and/or calibrated using equipment that is traceable to the National Institute for Standards and Technology (NIST). 20 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Maintenance Electric shock hazard: Before opening the case, remove the test leads from the circuit and shut off the unit. Failure to observe this warning could result in severe injury or death. Replacing the Batteries 1. Disconnect the unit from the circuit. Turn the unit OFF. 2. Remove the two screws from the battery access door and remove it. 3. Replace the batteries, making sure to observe the polarity. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter will not be used for periods longer than 60 days, remove the batteries and store them separately. 21 22 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Descripción Los medidores con pinza CM-660, CM-860, CM-960, CMH-600 y CMI-600 de Greenlee son unidades de prueba que caben perfectamente en la palma de la mano, capaces de efectuar los siguientes tipos de mediciones: Voltaje de CA y CC, corriente de CA, AmpTip™ para corriente de CA, frecuencia, detección de campos eléctricos (EF) sin contacto y resistencia. También sirven para verificar diodos y continuidad. Estos medidores están diseñados para ser colocados en o retirados de conductores con aislamiento o sin aislamiento. Entre las funciones adicionales específicas para cada modelo se incluyen: CMI-600 CM-960 Voltaje de CA + CC Función • • CMH-600 CM-860 AmpTip™ para corriente de CC • • AmpTip™ para corriente de CC + CA • • Corriente de CC • • Corriente de µCC • • Temperatura (termopar estilo K) • • Rotación del motor • • Rotación de fase • • Captura de RMS máximo • • • Capacitancia • • • • Luz de fondo • • • • Modo Cero • • • • Entre otras funciones se incluyen: • Modo de Retención para capturar el valor de LCD presente • Modo de Registro mínimo, máximo o promedio • Apagado automático inteligente • Escala automática Acerca de la seguridad Es fundamental observar métodos seguros al utilizar y dar mantenimiento a las herramientas y equipo Greenlee. Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la información necesaria para evitar riesgos y hábitos poco seguros relacionados con su uso. Siga toda la información sobre seguridad que se proporciona. Propósito de este manual Este manual de instrucciones tiene como propósito familiarizar a todo el personal con los procedimientos de operación y mantenimiento seguros para los medidores con pinzas CM-660, CM-860, CM-960, CMH-600, y CMI-600 de Greenlee. Manténgalo siempre al alcance de todo el personal. Puede obtener copias adicionales de manera gratuita, previa solicitud en www.greenlee.com. 23 Importante Información sobre Seguridad SÍMBOLO DE ALERTA SOBRE SEGURIDAD Este símbolo se utiliza para indicar un riesgo o práctica poco segura que podría ocasionar lesiones o daños materiales. Cada uno de los siguientes términos denota la gravedad del riesgo. El mensaje que sigue a dichos términos le indica cómo ­puede evitar o prevenir ese riesgo. Peligros inmediatos que, de no evitarse, OCASIONARÁN graves lesiones o incluso la muerte. Peligros que, de no evitarse, PODRÍAN OCASIONAR graves lesiones o incluso la muerte. Peligro o prácticas peligrosas que, de no evitarse, PUEDEN OCASIONAR lesiones o daños materiales. Lea y entienda este documento antes de manejar esta herramienta o darle mantenimiento. Utilizarla sin comprender cómo manejarla de manera segura podría ocasionar un accidente, y como resultado de éste, graves lesiones o incluso la muerte. Peligro de electrocución: El contacto con circuitos activados podría ocasionar graves lesiones o incluso la muerte. ¡No deseche ni descarte este producto! Para información sobre reciclaje, visite www.greenlee.com. Todas las especificaciones son nominales y pueden cambiar conforme tengan lugar mejoras de diseño. Greenlee Tools, Inc. no se hace responsable de los daños que puedan surgir de la mala aplicación o mal uso de sus productos. ® Registrado: El color verde para instrumentos de verificación eléctricos es una marca registrada de Tools, Innovations Inc. Amp-Tip es una marca comercial de BTC. 24 CONSERVE ESTE MANUAL CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Importante Información sobre Seguridad Peligro de electrocución e incendio: • No exponga esta unidad ni a la lluvia ni a la humedad. • No utilice esta unidad si se encuentra mojada o dañada. • Los medidores con pinza, las puntas de prueba o cualquier otro accesorio de cierre, cuando se utilizan para tomar una medición, crean un sistema. El sistema tiene capacidad nominal CAT III 600 V o CAT IV 300 V cuando se utilizan los cables de prueba o los accesorios suministrados con el medidor. El sistema CAT y la capacidad nominal de voltaje están limitados por el componente con capacidad mínima en el sistema cuando se utilizan cables de prueba o accesorios no suministrados con el medidor. • Revise minuciosamente los cables de prueba o el accesorio, antes de utilizarlos. Deberán estar limpios y secos, y su forro aislante deberá estar en buenas condiciones. No use el cable de prueba si está visible la capa de aislamiento interior de contraste. • Utilícela únicamente para el propósito para el que ha sido diseñada por el fabricante, tal como se describe en este manual. Cualquier otro uso puede menoscabar la protección proporcionada por la unidad. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: • No aplique más del voltaje nominal entre dos terminales de entrada cualesquiera, o entre una terminal de entrada cualquiera y una conexión a tierra. • Mantenga las manos y los dedos por debajo de las barreras en los cables de prueba y en el cuerpo del medidor con pinza. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: • No haga funcionar esta unidad con la caja abierta. • Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. 25 Importante Información sobre Seguridad Peligro de electrocución: • A menos que vaya a medir tensión, corriente o frecuencia, apague y bloquee la energía. Asegúrese de que todos los condensadores estén totalmente sin carga. No debe haber tensión alguna. • Coloque el interruptor de selección y conecte los cables de prueba de modo que correspondan al tipo de medición que se desea efectuar. Los ajustes o conexiones incorrectos pueden resultar en mediciones incorrectas o daños en la unidad. • Al utilizar esta unidad cerca de equipo que genere interferencia electromagnética quizá se obtenga una lectura inexacta e inestable. De no observarse estas advertencias podrían sufrirse graves lesiones o incluso la muerte. Peligro de electrocución: • No cambie la función de medición mientras los cables de prueba estén conectados a un componente o circuito. • No coloque la mordaza de la abrazadera alrededor de un conductor que porte una frecuencia mayor de 400 Hz. Los circuitos magnéticos podrían alcanzar una temperatura peligrosa si se excede esta frecuencia. De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad. Peligro de electrocución: • No intente reparar esta unidad, ya que contiene partes que deben recibir mantenimiento por parte de un profesional. • No exponga la unidad a ambientes de temperatura extrema o altos niveles de humedad. Consulte las Especificaciones. De no observarse estas precauciones podrían sufrirse lesiones o daños a la unidad. 26 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Identificación 1. Antena para detección de EF sin contacto 2. Indicador central en la mordaza para mejor precisión de corriente; indicador de polaridad para amperios de CC 3. Selecciona una función o apaga la unidad 4. LCD 5. Conector de entrada para las funciones de rotación de motor y fase únicamente 6. Terminal de entrada positiva; entrada L2 para rotación de motor y fase 7. Terminal de entrada negativo, común o conexión a tierra; entrada L1 para rotación de motor y fase 8. Consulte la explicación pertinente en la sección “Cómo utilizar las distintas funciones” 9. Palanca de mordaza 10. Mantenga la mano o los dedos por debajo de la línea de puntos durante la operación. 11. Mordaza 12. Indicador de centro para la función AmpTip™ 12 1 11 2 10 9 3 4 8 7 5 6 Símbolos en la unidad Advertencia — Lea el manual de instrucciones Advertencia — Peligro de electrocución Conexión a tierra Doble forro aislante CA (corriente alterna) CC (corriente continua) Se permite la aplicación o el retiro de la unidad alrededor de conductores energizados peligrosos. 27 Iconos de la pantalla 1. 2. 3. 4. 5. 6. 7. 8. 8.8.8.8 9. µ 10. F 11. A 12. V 13. Hz 14. Ω 15. k 16. 17. ∆ 18. – 19. VFD 20. 21. + 22. 23. 24. 25. MAX 26. MIN 27. AVG Está habilitada la selección automática de escala. Está habilitada la función Record (Grabar). Diodo Continuidad Está habilitado el modo PEAK-RMS. Suministro principal de rotación de fase Rotación del motor Pantalla numérica Micro (10-6) Faradio Amperio Voltio Hertzios (frecuencia en ciclos por segundo) Ohmios Kilo (103) AEstá habilitada la función AmpTip™. Está habilitada la función Cero relativo (Relative zero). Indicador de polaridad Medición de CA con filtro para precisión en variadores de frecuencia Está seleccionada la medición de CA. Está seleccionada la medición de CA + CC. Está seleccionada la medición de CC. Batería baja Está seleccionada la función Hold (Retención de datos en pantalla). Aparece el valor máximo Aparece el valor mínimo Aparece el valor promedio 1 2 3 4 5 28 21 19 23-27 22 6-7 20 8 18 17 9-12 16 28 15 14 13 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Cómo utilizar las distintas funciones Todos los modelos • REC: Oprima momentáneamente este botón para activar el modo de grabación MAX/MIN/AVG. y “MAX MIN AVG” aparecerán en la pantalla. El medidor emite un tono audible siempre que se actualice la lectura de valor máximo o mínimo. La lectura promedio se calcula en el transcurso del tiempo. Oprima momentáneamente el botón para leer en secuencia los valores MAX, MIN y AVG. Oprima el botón durante 1 segundo para salir del modo de grabación MAX/MIN/AVG. En este modo APO se inhabilita automáticamente. • SELECT: Oprímalo momentáneamente para alternar entre las funciones, modos de medición o modos de pantalla. El último ajuste utilizado se convierte en el valor por defecto cuando se vuelva a seleccionar dicha función. Para cambiar el valor por defecto, seleccione un nuevo ajuste. El ajuste será almacenado en una memoria estable. • HOLD: Oprima momentáneamente para retener en pantalla el valor actual. Oprímalo nuevamente para salir de este modo. • Apagado automático inteligente (APO): El medidor se apaga automáticamente después de aproximadamente 32 segundos de inactividad a fin de preservar la vida útil de la batería. La función activa del medidor se especifica como: Se gira el interruptor selector o se presionan los botones pulsadores; las lecturas por encima de 8.5% de la escala; lecturas de no OL para resistencia, continuidad, o función de diodos, lecturas diferentes de cero para la función HZ; rotación de fase de segmentos en movimiento. Para activar el medidor desde el apagado automático APO, oprima momentáneamente el botón SELECT y suéltelo o gire el interruptor rotativo a la posición OFF y después de regreso a la posición de encendido ON. Siempre gire el interruptor rotativo a la posición OFF cuando el medidor no esté en uso. CM-860, CM-960, CMH-600, y CMI-600 solamente : Oprima el botón SELECT durante 1 segundo para alternar la luz de fondo de la pantalla LCD. La luz de fondo se apagará automáticamente después de 32 segundos para prolongar la vida útil de la batería. • ∆: Oprima el botón ∆ durante 1 segundo para alternar entre cero y modo normal. En el modo cero el valor en la pantalla LCD cuando se oprime el botón se convierte en la desviación. A medida que cambia el valor de entrada, se resta la desviación del valor actual. Este valor modificado se muestra en la pantalla LCD. Nota: La operación ∆ cuando se seleccionan las funciones DCA o CC + CAA compensa cualquier histéresis magnética en la mordaza. Si la lectura de DCA o CC + CAA antes de la medición no es cero, entonces oprima el botón ∆ durante 1 segundo. En la pantalla LCD aparecerá “dc_0”. Cuando este valor desaparezca, el medidor estará listo para la operación. Cuando la lectura de medición sea mayor de 5 A, se inhabilita este modo. A manera de indicación el medidor emitirá tres pitidos. • CM-960, CMH-600, y CMI-600 solamente • PEAK-RMS (Máximo valor eficaz [RMS]): Oprima el botón PEAK-RMS durante 1 segundo para activar el modo PEAK-RMS y capturar la corriente pico o voltaje con duraciones de tan solo 80 ms. Aparece el en la pantalla. Oprima el botón durante 1 segundo para salir del modo PEAK-RMS. En este modo APO se inhabilita automáticamente. 29 Cómo utilizar las distintas funciones (continuación) CMH-600 y CMI-600 solamente • y : Si se desea, oprima sin soltar el botón REC a la vez que enciende el medidor para habilitar la función Beeper (Señal audible). Si los segmentos indican un movimiento hacia la derecha, la señal audible emitirá un solo pitido prolongado por ciclo de segmento. Si los segmentos indican un movimiento hacia la izquierda, la señal audible emitirá tres pitidos cortos por ciclo de segmento. • : Asegúrese que el motor esté eléctricamente aislado de su fuente de alimentación. Oprima el botón SELECT momentáneamente para seleccionar la función Motor. Conecte el medidor al motor según se describe en la sección “Tabla de ajustes” en este manual. Desde la perspectiva de arriba hacia abajo, gire el eje del motor hacia la derecha. Si el medidor indica un movimiento hacia la derecha, los cables de prueba del motor conectados a L1, L2 y L3 del medidor son T1, T2 y T3, respectivamente. Si el medidor indica un movimiento hacia la izquierda, intercambie cualesquiera dos conexiones entre el medidor y el motor. Después repita la prueba. • : Oprima el botón SELECT momentáneamente para seleccionar la función Fase. Conecte el medidor a las fases según se describe en la sección “Tabla de ajustes” en este manual. Si el medidor indica un movimiento hacia la derecha, las fases conectadas a L1, L2 y L3 del medidor son L1, L2 y L3, respectivamente. Si el medidor indica un movimiento hacia la izquierda, intercambie cualesquiera dos conexiones entre el medidor y las fases. Después repita la prueba. Cómo utilizar los cables de prueba Peligro de descarga eléctrica: Los cables de prueba suministrados con este producto cumplen con las normativas de seguridad que limitan la longitud expuesta de la punta de la sonda a 4 mm para mediciones en las categorías III y IV. Estos cables de prueba incluyen una tapadera que debe estar colocada en posición cuando se utilizan en aplicaciones con categoría de medición III o IV. De no observarse esta advertencia podrían sufrirse lesiones graves o incluso la muerte. La tapadera debe estar en posición para aplicaciones con categoría de medición III o IV. Se puede retirar la tapadera para aplicaciones con categoría de medición I o II. 30 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Medición de corriente alterna Las mediciones de corriente alterna generalmente se muestran como valores eficaces (RMS o root mean squared). El valor eficaz equivale al valor de una forma de onda de CC, la cual brinda la misma potencia que si reemplazara la forma de onda variable con el tiempo. Existen dos métodos de medición de corriente alterna: calibrados para responder al valor eficaz medio y a una lectura de valores eficaces reales. El método calibrado para responder al valor eficaz medio toma el valor medio de la señal de entrada luego de una rectificación total de onda, la multiplica por 1,11 y muestra el resultado. El resultado es exacto si la señal de entrada es una onda sinusoidal pura. El método de lectura de valores eficaces reales utiliza un circuito interno para leer el valor eficaz real. Este método es exacto, dentro de las limitaciones de factor de cresta especificadas, independientemente del tipo de señal de entrada, ya sea una onda sinusoidal pura, rectangular, triangular, media onda o señal con armónicas. La capacidad para leer valores eficaces reales brinda una mayor versatilidad de medición. Los modelos CM-660, CM-860, CM-960, CMH-600, y CMI-600 de Greenlee son medidores de RMS reales. La tabla de Formas de onda y Factores de cresta muestra algunas de las señales de CA y sus valores eficaces reales más comunes. Formas de onda y Factores de cresta Forma de onda Valor eficaz 100 100 100 100 Valor medio 90 100 87 64 Factor de cresta* (x) 1,414 1 1,73 2 * El factor de cresta es el cociente de un valor máximo en relación con el valor eficaz; está representado por la letra griega x. Valor eficaz real CA + CC El valor eficaz real CA + CC calcula los componentes de CA y CC expresados al efectuar mediciones y responde acertadamente al valor eficaz efectivo total independientemente de la forma de onda. Formas de onda distorsionadas con la presencia de componentes de CC y armónicas podrían ocasionar: • el sobrecalentamiento de transformadores, generadores y motores • el disparo prematuro de interruptores automáticos de circuito • que fusibles se quemen • el sobrecalentamiento de neutrales debido a la presencia de armónicas triples en el neutral • la vibración de barras colectoras y paneles eléctricos Los modelos CM-960 y CMI-600 pueden configurarse para mostrar RMS reales de CA o RMS reales de CA + CC. 31 Ancho de banda de CA El ancho de banda de CA es la escala de frecuencias sobre la cual se puede realizar mediciones de CA dentro de las tolerancias de precisión especificadas. Se trata de la respuesta de frecuencia de las funciones de CA—no de las funciones de medición de frecuencia. Un medidor no puede medir con precisión los valores de CA si los espectros de frecuencia están fuera de su ancho de banda. Las formas de onda complejas, el ruido y las formas de onda distorsionadas contienen componentes de frecuencia mucho mayores que los fundamentales; por ejemplo, ruido de alta frecuencia en una línea de energía de 50/60 Hz. Operación Peligro de electrocución: El contacto con circuitos activados podría ocasionar graves lesiones o incluso la muerte. Procedimiento de operación 1. Consulte la Tabla de ajustes. Coloque el interruptor de selección en el ajuste apropiado, oprima SELECT (cuando se le pida que lo haga), y conecte los cables de prueba al multímetro. 2. Consulte la sección “Mediciones más comunes” en relación con las instrucciones específicas para cada tipo de medición. 3. Pruebe la unidad en un circuito o componente que se sabe está funcionando perfectamente. • Si la unidad no funciona como debería en un circuito que se sabe está funcionando perfectamente, reemplace las baterías. • Si la unidad aún sigue sin funcionar como debería, llame a Greenlee al 800-4350786 para obtener asistencia técnica. 4. Anote la lectura del circuito o componente que se está verificando. 32 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Operación (continuación) Tabla de ajustes Coloque el Enseguida interruptor aparecen Para medir este valor … de selección estos en este iconos en la símbolo… pantalla… TODOS LOS MODELOS Conecte Conecte el cable el cable de prueba de prueba rojo a … negro a … Voltaje (CA) V + COM Voltaje (CC) V + COM Corriente, AmpTip™ (CA) A N/A N/A Corriente alterna (CA) A N/A N/A + COM + COM + COM + COM N/A COM Ω Continuidad Resistencia Ω kΩ V Diodo Frecuencia Campo eléctrico (EF)* Hz EF Hz EF CM-860, CM-960, CMH-600, y CMI-600 solamente µF Capacitancia** + COM + COM CM-960 y CMI-600 solamente Voltaje (CA + CC) Corriente, AmpTip™ (CC) A N/A N/A Corriente, AmpTip™ (CA + CC) A N/A N/A Corriente (CC) A N/A N/A Corriente (CA + CC) A N/A N/A CMH-600 y CMI-600 solamente Temperatura Corriente (µCC) Temp C or F µA *** + COM Rotación de fase† + COM Rotación del motor† + COM * Use el lado superior de la mordaza estacionaria, o para mediciones de mayor precisión use una sonda en el terminal COM. ** Descargue el condensador antes de efectuar una medición. Consulte “Mediciones típicas” respecto a los capacitores polarizados. *** Termopar + conexiones a +, termopar – conexiones a COM. † El cable amarillo se conecta a L3. 33 Mediciones típicas y precisión Consulte la sección “Especificaciones” en relación con las condiciones de operación y el coeficiente de temperatura. La precisión se especifica de la siguiente manera: ± (un porcentaje de la lectura + una cantidad fija) a 23 °C ± 5 °C (73,4 °F ± 9 °F). La frecuencia debe hallarse dentro del ancho de banda especificado para formas de onda no sinusoidales. Los factores de cresta, salvo que se especifique de manera diferente, son de la manera siguiente: • Factor de cresta < 2,5:1 a plena escala • Factor de cresta < 5,0:1 a escala media Frecuencia Sensibilidad (sinusoidal RMS)* 50 V 40 A 40 A Función 600 V 60,0 A AmpTip™ 60,00 A, 600,0 A Escala 5,00 Hz ~ 999,9 Hz 50,00 Hz ~ 400,0 Hz 50,00 Hz ~ 400,0 Hz * La desviación de CC debe ser menor que el 50% del valor sinusoidal RMS. Precisión de la escala de frecuencias Escala de la pantalla xx.xx xxx.x Precisión ± (1,0% + 0,05 Hz) ± (1,0% + 0,5 Hz) Medición de voltaje EF Hz V VFD VFD SELECT Voltaje de CA Escala Precisión a 50 Hz a 60 Hz 600,0 ± (1,0% + 0,5 V) SELECT Voltaje de CC Escala Precisión 600,0 ± (1,0% + 0,5 V) Voltaje de CA + CC (CM-960 y CMI-600 solamente)) Escala Precisión en CC, 50 Hz a 60 Hz 600,0 ± (1,2% + 0,7 V) Impedancia de entrada: 10 MΩ, 100 pF nominal 34 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mediciones típicas y precisión (continuación) Medición de corriente Corriente µA CC Sensor llama Flame de Sensor µA Llama piloto Pilot Flame TarjetaControl de control Board Corriente de μCC (CMH-600 y CMI-600 solamente) Escala 200,0 μA 2000 μA Función AmpTip™ Precisión ± (1,0% + 0,5 μA) ± (1,0% + 5 μA) 60,00 A A 3,5 mV/μA Corriente de CA AmpTip™ Escala Hz Voltaje de carga Escala de precisión < 0,20 A* 0,00 A a 3,99 A 4,00 A a 60,00 A Precisión a 50 Hz a 60 Hz** No especificada ± (1,5% + 0,15 A) ± (1,5% + 0,05 A) * Para CM-660, CM-860 y CMH-600 solamente. ** Para CM-960 y CMI-600 solamente, el error inducido por conductores adyacentes portadores de corriente es < 0,01 A/A. Corriente de CC AmpTip™ (CM-960 y CMI-600 solamente) Escala 60,00 A Escala de precisión 0,00 A a 3,99 A 4,00 A a 60,00 A Precisión† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) Corriente de CC + CA AmpTip™ (CM-960 y CMI-600 solamente) Escala 60,00 A Escala de precisión 0,00 A a 3,99 A 4,00 A a 60,00 A Precisión en CC, 50 Hz a 60 Hz† ± (2,0% + 0,17 A) ± (2,0% + 0,07 A) † El error inducido para conductores adyacentes portadores de corriente es < 0,01 A/A. Nota: Use ∆ si hay una desviación antes de que se tome la medición. 35 Mediciones típicas y precisión (continuación) Medición de corriente (continuación) Pinza para CA y CC Hz A Corriente de CA (CM-960 y CMI-600 solamente) Precisión a Escala Escala de precisión 50 Hz a 100 Hz*† 0,00 A a 8,99 A ± (1,8% + 0,15 A) 60,00 A 9,00 A a 60,00 A ± (1,8% + 0,05 A) 600,0 A 60,0 A a 600,0 A ± (1,8% + 0,5 A) Precisión a 100 Hz a 400 Hz*† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) * Factor de cresta máximo < 2:1 a escala completa y < 4:1 a media escala. Corriente de CA (CM-660, CM-860, y CMH-600 solamente) Precisión a Escala Escala de precisión 50 Hz a 100 Hz*† 0,00 A a 0,19 A No especificada 60,00 A 0,20 A a 5,99 A ± (1,8% + 0,15 A) 6,00 A a 60,00 A ± (1,8% + 0,05 A) 600,0 A 60,0 A a 600,0 A ± (1,8% + 0,5 A) Precisión a 100 Hz a 400 Hz*† No especificada ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) * Para cualquier medición, cuando el conductor no esté posicionado en el centro de las mordazas, agregue 2,0% a la precisión para compensar el error de posición. Corriente de CC (CM-960 y CMI-600 solamente) Escala Escala de precisión 0,00 A a 8,99 A 60,00 A 9,00 A a 60,00 A 600,0 A 60,0 A a 600,0 A Corriente de CA + CC (CM-960 y CMI-600 solamente) Precisión a Escala Escala de precisión 50 Hz a 100 Hz† 0,00 A a 8,99 A ± (2,2% + 0,15 A) 60,00 A 9,00 A a 60,00 A ± (2,2% + 0,05 A) 600,0 A 60,0 A a 600,0 A ± (2,2% + 0,5 A) Precisión† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) Precisión a 100 Hz a 400 Hz† ± (2,7% + 0,17 A) ± (2,7% + 0,07 A) ± (2,7% + 0,7 A) † El error inducido para conductores adyacentes portadores de corriente es < 0,01 A/A. Nota: Use ∆ si hay una desviación antes de que se tome la medición. 36 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mediciones típicas y precisión (continuación) Medición de resistencia Resistencia Escala 600,0 Ω 6,000 kΩ 60,00 kΩ Ω Precisión ± (1,0% + 0,5 Ω) ± (1,0% + 0,005 kΩ) ± (1,0% + 0,05 kΩ) Voltaje de circuito abierto: 1,0 V CC SELECT Verificación de continuidad Continuidad Umbral de tono: Entre 10 Ω y 250 Ω Tiempo de respuesta: Aproximadamente 32 ms. SELECT Medición de capacitancia Capacitancia (CM-860, CM-960, CMH-600, y CMI-600 solamente) Escala 200,0 μF 2500 μF Precisión* ± (2,0% + 0,4 μF) ± (2,0% + 4 μF) * Para los capacitores de película (capacitores con absorción dieléctrica insignificante). Nota: Para condensadores polarizados, conecte la sonda roja al terminal positivo y la sonda negra al terminal negativo del condensador. 37 Mediciones típicas y precisión (continuación) Verificación de diodo Polarización inversa Polarización directa Verificación de diodos Escala de medición: 2,000 V Precisión: ± (1,5% + 0,005 V) Corriente de prueba (típica): 0,3 mA Voltaje de circuito abierto (típica): < 3,5 V CC SELECT Temperatura Temperatura (CMH-600 y CMI-600) Escala -40,0 °C ~ 99,9 °C 100 °C ~ 400 °C -40,0 °F ~ 211,8 °F 212 °F ~ 752 °F Precisión* ± (1,0% + 0,8 °C) ± (1,0% + 1 °C) ± (1,0% + 1,5 °F) ± (1,0% + 2 °F) * La precisión del termopar tipo K no está incluida. Los termopares suministrados con el medidor cumplen las normativas JIS C 16021981. SELECT 38 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mediciones típicas y precisión (continuación) 10 mm (0.4") A Campo eléctrico Nota: CM-660 y CM-860 tienen una posición dedicada de interruptor. Detección de EF sin contacto Voltaje típico 20 V 55 V 110 V 220 V 440 V Escala de 50 Hz a 60 Hz 10 V ~ 36 V 23 V ~ 83 V 59 V ~ 165 V 124 V ~ 330 V 250 V ~ 600 V Indicación en LCD ----------- SELECT B A–Sin contacto O BIEN B–Con contacto, medición de precisión Rotación de fase Rotación del motor SELECT Clockwise A la derecha Counterclockwise A la izquierda 39 Especificaciones Pantalla: LCD, 3-5/6 dígitos 6000 puntos Polaridad: Automática Frecuencia de actualización: 5 por segundo, nominal Condiciones de funcionamiento: 0 °C a 31 (32 °F a 88 °F), 0% a 80% de humedad relativa 31 °C a 40 (88 °F a 104 °F), humedad relativa disminuyendo linealmente de 80% a 50% Grado de contaminación: 2 Uso en interiores únicamente Altitud: Funcionando por debajo de 2000 m (6500 pies) Temperatura de almacenamiento: -20 °C a 60 °C, humedad relativa < 80%, sin baterías Coeficiente de temperatura: Nominal 0,15 x (Precisión) por °C debajo de 18 °C desde 0 °C hasta 18 °C (32 °F hasta 64,4 °F) y por encima de 28 °C, desde 28 °C hasta 40 °C (82,4 °F hasta 104 °F) a menos que se especifique de manera diferente Detección: Valores eficaces (RMS) reales E.M.C.: Cumple EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) En un campo de RF de 1 V/m a una frecuencia de 405 MHz, CC A y modo CC+CA A (CM-960 y CMI-960): Precisión total = Precisión especificada + 20 dígitos En un campo de RF de 1 V/m, modo Resistencia (todos los modelos) y modo µA CC (CMH-600 y CMI-600): Precisión total = Precisión especificada + 25 dígitos En un campo de RF de 3 V/m, y todos los otros modos y modelos no especificados anteriormente: Precisión total = Precisión especificada + 20 dígitos Seguridad: Doble aislamiento según UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed. 1, CAN/CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed. 2 y IEC/EN61010031 Ed. 1.1 para CAT III 600 V y CAT IV 300 V CA y CC Protecciones contra sobrecarga: Mordazas: Función Corriente con frecuencia: 600 A CC/CA RMS a ≤ 400 Hz Terminales: Función Voltaje y Rotación de fase: 660 V CC/920 V CA RMS Todos los otros modos y funciones: 600 V CC/CA RMS Protección contra corrientes transitorias: 6,0 kV (1,2/50 µs sobrevoltaje) Fuente de alimentación: Dos baterías de 1,5 V AAA (NEDA 24 A o IEC LR03) Batería baja: Función Capacitancia y Frecuencia: Aproximadamente 2,85 V Toda otra función: Aproximadamente 2,5 V Consumo de corriente: CM-960 y CMI-600: Típicamente 13 mA CM-660, CM-860 y CMH-600: Típicamente 4,3 mA Sincronización de APO: Marcha en vacío durante 32 minutos Consumo de APO: 5 µA típico Dimensiones: CM-960 y CMI-600: 222 mm x 76 mm x 37 mm (8,7 pulg. x 3,0 pulg. x 1,4 pulg.) CM-660, CM-860 y CMH-600: 217 mm x 76 mm x 37 mm (8,5 pulg. x 3,0 pulg. x 1,4 pulg.) Apertura de mordazas y diámetro del conductor: 30 mm máx. (1,18 pulg.) 40 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Categorías de medición Las siguientes definiciones proceden de la norma de seguridad internacional sobre la coordinación de­aislamientos tal y como se aplica a equipos de medición, control y laboratorio. En las publicaciones IEC 61010-1 y IEC 60664 de la International Electrotechnical Commission (Comisión Electrotécnica Internacional) se detallan más a fondo estas categorías de medición. Categoría de medición II Nivel local. Aparatos eléctricos, equipo portátil, y los circuitos a los que están conectados. Como ejemplo pueden citarse dispositivos de iluminación, televisores y circuitos de rama larga. Categoría de medición III Nivel de distribución. Máquinas instaladas permanentemente y los circuitos a los que están cableados. Como ejemplo pueden citarse sistemas conductores y los paneles del interruptor automático principal del sistema eléctrico de un edificio. Categoría de medición IV Nivel de abastecimiento primario. Líneas aéreas y otros sistemas de cable. Como ejemplo pueden citarse cables, medidores, transformadores y cualquier otro equipo exterior perteneciente a la empresa de servicio eléctrico. Certificado de Conformidad Greenlee Tools, Inc. cuenta con certificación conforme a ISO 9001 (2000) para nuestros Sistemas de Gerencia de Calidad. El instrumento provisto ha sido inspeccionado y/o calibrado mediante el uso de equipo reconocido por el Instituto Nacional de Normas y Tecnologías (National Institute for Standards and Technology [NIST]). 41 Mantenimiento Peligro de electrocución: Antes de abrir la caja, retire del circuito los cables de prueba y apague la unidad. De no observarse esta advertencia podrían sufrirse graves lesiones o incluso la muerte. Reemplazo de las baterías 1. Desconecte la unidad del circuito. Apague (OFF) la unidad. 2. Extraiga los dos tornillos de la puerta de acceso a la batería y retírela. 3. Cambie las baterías y verifique la polaridad, limpieza y almacenamiento. Limpieza y almacenamiento Limpie periódicamente la caja utilizando un paño húmedo y detergente suave; no utilice abrasivos ni solventes. Si el medidor no se utilizará durante períodos de más de 60 días, extraiga la batería y guárdela separadamente. 42 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Description Les contrôleurs à pince CM-660, CM-860, CM-960, CMH-600 et CMI-600 de Greenlee sont des appareils de contrôle portables offrant les capacités de mesure suivantes : tension alternative et continue, intensité alternative, AmpTip™ pour intensité alternative, fréquence, détection de champ électrique (EF) sans contact et résistance. Ils permettent également la vérification de diodes et les contrôles de continuité. Ces contrôleurs sont conçus pour être utilisés sur des conducteurs isolés ou non isolés. Fonctionnalités supplémentaires propres à certains modèles : Fonction CMI-600 CM-960 CMH-600 CM-860 Tension alternative + continue • • AmpTip™ pour intensité continue • • AmpTip™ pour intensité cont. + alt. • • Intensité continue • • Micro-intensité continue • • Température (thermocouple de type K) • • Rotation de moteur • • Rotation de phase • • Saisie de valeurs efficaces de crête • • • Capacité • • • • Rétroéclairage • • • • Mode zéro • • • • Autres capacités : • Mode de maintien pour saisir la valeur affichée en cours • Mode d’enregistrement de minimum, maximum ou moyenne • Mise hors tension automatique intelligente • Sélection automatique du calibre Sécurité Lors de l’utilisation et de l’entretien des outils et des équipements de Greenlee, votre sécurité est une priorité. Ce manuel d’instructions et toute étiquette sur l’outil fournit des informations permettant d’éviter des dangers ou des manipulations dangereuses liées à l’utilisation de cet outil. Suivre toutes les consignes de sécurité indiquées. Dessein de ce manuel Ce manuel a pour objet de familiariser l’utilisateur avec les procédures préconisées pour une utilisation et un entretien sans danger des contrôleurs à pince CM-660, CM-860, CM-960, CMH-600, et CMI-600 de Greenlee. Mettre ce manuel à la disposition de tous les employés. On peut obtenir des exemplaires gratuits sur simple demande sur le site Web www.greenlee.com. 43 Consignes de sécurité importantes SYMBOLE D’AVERTISSEMENT Ce symbole met en garde contre les risques et les manipulations dangereuses pouvant entraîner des blessures ou l’endommagement du matériel. Le mot indicateur, défini ci-dessous, indique la gravité du danger. Le message qui suit le mot indicateur indique comment ­empêcher le danger. Danger immédiat qui, s’il n’est pas pris en considération ENTRAINERA des blessures graves, voire mortelles. Danger qui, s’il n’est pas pris en considération, POURRAIT entraîner des blessures graves, voire mortelles. Dangers ou manipulations dangereuses qui, s’ils ne sont pas pris en considération, POURRAIENT EVENTUELLEMENT entraîner des dommages à la propriété ou causer des blessures. Lire attentivement et bien comprendre cette documentation avant d’utiliser ou de procéder à l’entretien de cet équipement. Négliger de comprendre comment utiliser cet outil en toute sécurité pourrait provoquer un accident et entraîner des blessures graves, voire mortelles. Risque de décharge électrique : Un contact avec des circuits sous tension pourrait entraîner des blessures graves, voire mortelles. Ne pas se débarrasser de ce produit ou le jeter ! Pour des informations sur le recyclage, visiter www.greenlee.com. Toutes les spécifications sont nominales et peuvent changer avec l’amélioration de la conception. Greenlee Tools, Inc. ne peut être tenue responsable des dommages résultant d’une application inappropriée ou d’un mauvais usage de ses produits. ® Déposé : La couleur verte des instruments de vérification électrique est une marque déposée de Tools, Innovations Inc. AmpTip est une marque de commerce de BTC. 44 CONSERVER CE MANUEL CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Consignes de sécurité importantes Risques de décharge électrique et d’incendie : • Ne pas exposer cet appareil à la pluie ou à l’humidité. • Ne pas utiliser cet appareil s’il est mouillé ou endommagé. • Le contrôleur à pince, les fils de mesure ou tout autre accessoire de la pince, lorsqu’ils sont utilisés pour effectuer une mesure, constituent un système. Ce système est classé CAT III 600 V ou CAT IV 300 V si les fils de mesure ou les accessoires fournis avec l’appareil sont utilisés. La catégorie (CAT) et la classe de tension du système sont limités par l’élément du système de classe la plus basse en cas d’utilisation de fils de mesure ou d’accessoires non fournis avec l’appareil • Vérifier les fils de mesure ou l’accessoire avant de les utiliser. Ils doivent être propres et secs et l’isolation doit être en bon état. Ne pas utiliser un fil de mesure si la gaine isolante intérieure de couleur contrastée est visible. • Utiliser cet appareil uniquement dans le but pour lequel il a été conçu, tel que décrit dans ce manuel. Toute autre utilisation peut altérer le système de protection de cet appareil. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : • Ne pas appliquer plus que la tension nominale entre deux bornes d’entrée, ou entre une borne d’entrée et une prise de terre. • Tenir les mains et les doigts en dessous des gardes sur les fils de mesure et le corps du contrôleur à pince. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : • Ne pas utiliser lorsq ue le boîtier est ouvert. • Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. 45 Consignes de sécurité importantes Risques de décharge électrique : • Sauf si l’on mesure la tension, le courant ou la fréquence, mettre hors tension et couper la source d’alimentation. S’assurer que tous les condensateurs sont déchargés. Aucune tension ne doit être présente. • Régler le sélecteur et raccorder les fils de mesure comme il se doit pour la mesure à effectuer. Des réglages ou branchements incorrects peuvent produire des mesures inexactes ou endommager l’appareil. • L’utilisation de cet appareil à proximité d’équipements qui génèrent des interférences électromagnétiques peut produire des lectures instables ou erronées. L’inobservation de ces consignes pourrait entraîner des blessures graves, voire mortelles. Risques de décharge électrique : • Ne pas modifier la fonction de mesure pendant que les fils d’essai sont connectés à un composant ou à un circuit. • Ne pas placer la mâchoire autour d’un conducteur transportant un courant de plus de 400 Hz de fréquence. Le circuit magnétique peut atteindre une température dangereuse en cas de dépassement de cette fréquence. L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner des blessures. Risques de décharge électrique : • Ne pas tenter de réparer cet appareil. Il ne comporte aucune pièce pouvant être réparée. • Ne pas exposer l’appareil à des températures ou à une humidité extrêmes. Voir les caractéristiques techniques. L’inobservation de ces consignes pourrait endommager l’appareil et pourrait entraîner des blessures. 46 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Identification 1. Antenne pour détection de champ électrique (EF) sans contact 2. Indicateur de centre de mâchoire pour mesurer les intensités avec précision ; indicateur de polarité pour les intensités continues 3. Sélecteur de fonction ou de mise hors tension 4. Écran à cristaux liquides 5. Prise d’entrée pour la détection de rotation de phase et de moteur seulement 6. Borne d’entrée positive ; entrée L2 pour rotation de moteur et de phase 7. Borne d’entrée négative, commune ou de terre ; entrée L1 pour rotation de moteur et de phase 8. Voir l’explication sous « Utilisation des fonctions » 9. Levier de mâchoire 10. Garder les mains et les doigts sous le trait pointillé durant l’utilisation. 11. Mâchoire 12. Indicateur de centre pour la fonction AmpTip™ 12 1 11 2 10 9 3 4 8 7 5 6 Symboles sur l’appareil Avertissement — Lire le mode d’emploi Avertissement — Risque de décharge électrique Terre Double isolation Courant alternatif (AC) Courant continu (DC) Peut être placé autour de conducteurs sous tension dangereuse ou en être enlevé. 47 Icônes de l’afficheur 1. 2. 3. 4. 5. 6. 7. 8. 8.8.8.8 9. µ 10. F 11. A 12. V 13. Hz 14. Ω 15. k 16. 17. ∆ 18. – 19. VFD 20. 21. 22. 23. 24. 25. 26. 27. + MAX MIN AVG Sélection de calibre automatique activée Fonction d’enregistrement activée Diode Continuité Mode crête-efficace activé Rotation de phase alimentation principale Rotation de moteur Affichage numérique Micro (10-6) Farad Ampère Volt Hertz (fréquence en cycles par seconde) Ohm Kilo (103) Fonction AmpTip™ activée Fonction de zéro relatif activée Indicateur de polarité Filtre pour mesures en courant alternatif exactes sur les variateurs de vitesse (VFD) Mesure de courant alternatif sélectionnée Mesure de courant alternatif + continu sélectionnée Mesure de courant continu sélectionnée Pile déchargée Fonction de rétention activée Valeur maximale affichée Valeur minimale affichée Valeur moyenne affichée 1 2 3 4 5 28 21 19 23-27 22 6-7 20 8 18 17 9-12 16 48 15 14 13 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Utilisation des fonctions Tous les modèles • REC : Appuyer brièvement pour activer le mode d’enregistrement MAX/MIN/AVG. et « MAX MIN AVG » s’affichent à l’écran. L’appareil émet un bip à chaque mise à jour du maximum ou du minimum. La mesure moyenne (AVG) est calculée sur la durée. Appuyer brièvement sur cette touche pour afficher successivement les mesures MAX, MIN et AVG. Appuyer sur la touche pendant 1 seconde pour quitter le mode d’enregistrement MAX/MIN/AVG. L’APO est désactivé automatiquement dans ce mode. • SELECT : Appuyer brièvement pour passer d’une fonction, d’un mode de mesure ou d’un mode d’affichage à l’autre. Le dernier réglage utilisé devient le réglage par défaut lorsque la fonction considérée est sélectionnée une nouvelle fois. Pour changer de réglage par défaut, en sélectionner un nouveau. Le réglage est conservé dans une mémoire non volatile. • HOLD : Appuyer brièvement pour figer l’affichage de la valeur courante. Appuyer une nouvelle fois pour quitter ce mode. • Mise hors tension automatique intelligente (APO) : L’appareil s’éteint automatiquement au bout de 32 minutes d’inactivité environ pour économiser la pile. Le contrôleur est considéré comme actif dans les cas suivants : sélecteur tourné ou bouton-poussoir enfoncé ; mesures supérieures à 8,5 % du calibre ; mesures sans surcharge de résistance, de continuité ou de fonction de diode ; mesure de fréquence non nulle ; segment de rotation de phase en mouvement. Pour réactiver le contrôleur depuis le mode APO, appuyer brièvement sur la touche SELECT ou placer le bouton sélecteur tournant sur OFF puis le ramener en position de marche. Toujours mettre le sélecteur tournant en position OFF lorsque le contrôleur n’est pas utilisé. CM-860, CM-960, CMH-600 et CMI-600 seulement : Appuyer sur la touche SELECT pendant 1 seconde pour allumer et éteindre le rétroéclairage de l’écran. Le rétroéclairage s’éteint automatiquement au bout de 32 secondes pour économiser la pile. • ∆ : Appuyer sur la touche ∆ pendant 1 seconde pour alterner entre le mode zéro et le mode normal. En mode zéro, la valeur à l’écran au moment où la touche est enfoncée devient le facteur de correction. À mesure que la valeur d’entrée varie, ce facteur de correction est retranché de la valeur mesurée. L’écran affiche la valeur modifiée résultante. Remarque : L’utilisation de ∆ lorsque les fonctions d’intensité continue ou d’intensité continue + alternative sont sélectionnées a pour effet de décaler l’hystérésis magnétique dans la mâchoire. Si la valeur d’intensité continue ou continue + alternative avant la mesure n’est pas nulle, appuyer sur la touche ∆ pendant 1 seconde. L’écran affiche alors « dc_0 ». Quand ce message s’efface, l’appareil est prêt à l’utilisation. Lors de mesures de plus de 5 A, ce mode est désactivé. L’appareil émet alors trois bips pour l’indiquer. • CM-960, CMH-600 et CMI-600 seulement • PEAK-RMS : Appuyer sur la touche PEAK-RMS pendant 1 seconde pour activer le mode PEAK-RMS (crête-efficace) afin d’effectuer l’acquisition de l’intensité ou la tension d’appel pendant une durée de 80 ms ou plus. s’affiche à l’écran. Appuyer sur la touche pendant 1 seconde pour quitter le mode PEAK-RMS. L’APO est désactivé automatiquement dans ce mode. CMH-600 et CMI-600 seulement • et : Le cas échéant, tenir la touche REC enfoncée durant la mise en marche de l’appareil pour activer la fonction de bip. Si les segments indiquent un mouvement dans le sens des aiguilles d’une montre, l’appareil émet un bip long unique par cycle. Si les segments indiquent un mouvement dans le sens inverse, l’appareil émet trois bips courts par cycle. • : S’assurer que le moteur est isolé électriquement de sa source d’alimentation. Appuyer brièvement sur la touche SELECT pour sélectionner la fonction Moteur. Raccorder l’appareil au moteur conformément aux indications de la section « Tableau des réglages » de ce manuel. Faire tourner l’arbre du moteur dans le sens des aiguilles d’une montre, vu depuis le côté arbre du moteur. Si l’appareil indique un mouvement dans le sens des aiguilles d’une montre, les fils 49 Utilisation des fonctions (suite) du moteur raccordés à L1, L2 et L3 sur l’appareil sont, respectivement, T1, T2 et T3. Si l’appareil indique un mouvement inverse, inverser deux raccordements quelconques entre le contrôleur et le moteur. Refaire ensuite l’essai. • : Appuyer brièvement sur la touche SELECT pour sélectionner la fonction Phase. Raccorder l’appareil aux phases conformément aux indications de la section « Tableau des réglages » de ce manuel. Si l’appareil indique un mouvement dans le sens des aiguilles d’une montre, les phases raccordées à L1, L2 et L3 sur l’appareil sont, respectivement, L1, L2 et L3. Si l’appareil indique un mouvement inverse, inverser deux raccordements quelconques entre le contrôleur et les phases. Refaire ensuite l’essai. Utilisation des fils de mesure Danger de choc électrique : Les fils de mesure fournis avec ce produit sont conformes à des normes de sécurité qui limitent la longueur exposée d’embout de sonde à 4 mm pour les catégories de mesure III et IV. Ces fils de mesure comportent un capuchon qui doit être en place pour effectuer des mesures de catégorie III ou IV. Le non-respect de cette mise en garde peut entraîner des blessures graves ou la mort. Le capuchon doit être en place pour effectuer des mesures de catégorie III ou IV. Le capuchon peut être retiré pour les mesures de catégorie I ou II. 50 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mesure de courant alternatif En règle générale, les mesures de courant alternatif sont affichées en valeurs efficaces (RMS). La valeur efficace équivaut à la valeur d’une forme d’onde de courant continu, qui fournirait la même puissance si elle remplaçait la forme d’onde qui varie en fonction du temps. Les deux méthodes de mesure du courant alternatif sont la mesure de valeur efficace de réponse moyenne étalonnée et la mesure de valeur efficace vraie. La méthode par valeur efficace de réponse moyenne étalonnée consiste à mesurer la valeur moyenne du signal d’entrée après un redressement à double alternance, à la multiplier par 1,11 et à afficher le résultat. Cette méthode est précise si le signal d’entrée est une onde sinusoïdale pure. La méthode par mesure de la valeur efficace vraie fait appel à un circuit interne permettant de mesurer directement la valeur efficace. Cette méthode est précise dans les limites du facteur de crête spécifiées, que le signal soit une onde sinusoïdale pure, une onde carrée, une onde triangulaire, une demi-onde ou un signal comportant des harmoniques. Les appareils à mesure de valeur efficace vraie sont beaucoup plus polyvalents que les appareils conventionnels. Les contrôleurs CM-660, CM-860, CM-960, CMH-600, et CMI-600 de Greenlee sont des multimètres à valeur efficace vraie (True RMS). Le tableau des formes d’onde et facteurs de crête fournit les valeurs efficaces des signaux alternatifs courants. Formes d’ondes et facteurs de crêtes Forme d’onde Valeur RMS Valeur moyenne Facteur de crête* (x) 100 90 1,414 100 100 1 100 87 1,73 100 64 2 * Le facteur de crête correspond au rapport de la valeur de crête sur la valeur efficace ; il est représenté par la lettre grecque x. Valeur efficace vraie AC + DC La valeur efficace vraie AC + DC distingue les composantes alternative et continue suivant l'expression données par l’expression lors de la prise des mesures et reproduit avec précision la valeur efficace vraie totale réelle indépendamment de la forme d’onde. Les formes d’ondes déformées par la présence de composantes continues et d’harmoniques peuvent entraîner : • une surchauffe des transformateurs, des groupes électrogènes et des moteurs • un déclenchement prématuré des disjoncteurs • une condition où les fusibles vont griller • une surchauffe des neutres à cause de la triple harmonique présente dans le neutre • une vibration des barres omnibus et des panneaux électriques Les modèles CM-960 et CMI-600 peuvent être configurés pour afficher les valeurs efficaces vraies des mesures de courant alternatif ou de courant alternatif + continu. 51 Bande passante en courant alternatif La bande passante en courant alternatif est la plage de fréquences sur laquelle les mesures de courant alternatif peuvent être effectuées dans les limites d’incertitude indiquées. Il s’agit de la réponse en fréquence des fonctions de mesure en courant alternatif, pas des fonctions de mesure de fréquence. Une valeur de courant alternatif ne peut pas être mesurée avec précision dans des spectres de fréquence en dehors de la bande passante de l’appareil. Les formes d’onde complexes, le bruit et les formes d’onde ayant subi une distorsion contiennent des composantes de fréquence beaucoup plus élevée que la fondamentale. Exemple : le bruit haute fréquence sur une ligne haute tension de 50 ou 60 Hz. Utilisation Risque de décharge électrique : Un contact avec des circuits sous tension pourrait entraîner des blessures graves, voire mortelles. Mode d'emploi 1. Se reporter au Tableau des réglages. Placer le sélecteur sur le réglage qui convient, appuyer sur SELECT (lorsque l'instruction en est donnée) et raccorder les fils d'essai au multimètre. 2. Voir les instructions de mesure particulières sous « Mesures types ». 3. Tester l’appareil sur un circuit ou un composant connu. • Si l’appareil ne fonctionne pas comme prévu sur un circuit opérationnel connu, changer les piles. • Si l’appareil ne fonctionne toujours pas comme prévu, appeler le service d'assistance technique de Greenlee au 800-435-0786. 4. Effectuer la mesure sur le circuit ou le composant à contrôler. 52 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Utilisation (suite) Tableau des réglages Régler le Ces icônes Raccorder Raccorder sélecteur sur s’affichent à le fil rouge le fil noir ce symbole … l’écran … à… à… TOUS MODÈLES Pour mesurer cette valeur … Tension (alternative) V + COM Tension (continue) V + COM Intensité, AmpTip™ (alt.) A Néant Néant Intensité (alternative) A Néant Néant + COM + COM + COM + COM Néant COM Ω Continuité Ω Résistance kΩ V Diode Hz EF Fréquence Champ électrique (EF)* Hz EF CM-860, CM-960, CMH-600 et CMI-600 seulement µF Capacité** + COM + COM CM-960 et CMI-600 seulement Tension (alt. + cont.) Intensité, AmpTip™ (cont.) A Néant Néant Intensité, AmpTip™ (alt. + cont.) A Néant Néant Intensité (continue) A Néant Néant Intensité (alternative + continue) A Néant Néant CMH-600 et CMI-600 seulement Température Intensité (micro, alt.) Temp C ou F µA *** + COM Rotation de phase† + COM Rotation de moteur† + COM * Utiliser la partie supérieure de la mâchoire fixe ou, pour obtenir des mesures plus précises, utiliser une sonde branchée sur la borne COM. ** Décharger les condensateurs avant la mesure. Voir « Mesures types » concernant les condensateurs polarisés. *** Le + du thermocouple sur +, le – du thermocouple sur COM. † Fil jaune sur L3. 53 Mesures types et incertitude Voir les conditions d’utilisation et le coefficient de température dans la section « Caractéristiques techniques ». L’incertitude est spécifiée comme suit : ± (un pourcentage de la mesure + une quantité fixe) à 23 °C ± 5 °C (73,4 °F ± 9 ºF). La fréquence doit être dans les limites de la largeur de bande spécifiée pour les ondes non sinusoïdales. Sauf indication contraire, les facteurs de crête sont les suivants : • Facteur de crête < 2,5:1 à pleine échelle • Facteur de crête < 5,0:1 à mi-échelle Fréquence Fonction 600 V 60,0 A AmpTip™ 60,00 A, 600,0 A Sensibilité (eff. sinus.)* 50 V 40 A 40 A Calibre 5,00 Hz ~ 999,9 Hz 50,00 Hz ~ 400,0 Hz 50,00 Hz ~ 400,0 Hz * La tension de polarisation (DC Bias) doit être inférieure à 50 % de la valeur efficace sinusoïdale. Incertitude de la mesure de fréquence Plage d’affichage xx.xx xxx.x Incertitude ± (1,0% + 0,05 Hz) ± (1,0% + 0,5 Hz) Mesure de tension EF Hz V VFD VFD SELECT Tension alternative Calibre Incertitude de 50 Hz à 60 Hz 600,0 ± (1,0% + 0,5 V) SELECT Tension continue Calibre Incertitude 600,0 ± (1,0% + 0,5 V) Impédance d’entrée : 10 MΩ, 100 pF nominal 54 Tension alt. + cont. (CM-960, CMI-600 seulement) Incertitude Calibre cour. cont., de 50 Hz à 60 Hz 600,0 ± (1,2% + 0,7 V) CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mesures types et incertitude (suite) Mesure d’intensité de courant µA continu Détecteur de flamme Flame Sensor µA Pilot Flame Veilleuse CircuitControl de commande Board Micro-intensité continue (CMH-600 et CMI-600 seulement) Calibre 200,0 μA 2000 μA Fonction AmpTip™ Incertitude ± (1,0% + 0,5 μA) ± (1,0% + 5 μA) Tension absorbée Intensité alternative AmpTip™ Calibre Plage de mesure < 0,20 A* 60,00 A 0,00 A à 3,99 A 4,00 A à 60,00 A Hz A 3,5 mV/μA Incertitude de 50 Hz à 60 Hz** Non spécifié ± (1,5% + 0,15 A) ± (1,5% + 0,05 A) * CM-660, CM-860 et CMH-600 seulement. ** Pour CM-960 et CMI-600 seulement, l’erreur induite pour les conducteurs voisins est < 0,01 A/A.. Intensité continue AmpTip™ (CM-960 et CMI-600 seulement) Calibre Plage de mesure 0,00 A à 3,99 A 60,00 A 4,00 A à 60,00 A Incertitude† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) Intensité cont. + alt. AmpTip™ (CM-960 et CMI-600 seulement) Calibre Plage de mesure 60,00 A 0,00 A à 3,99 A 4,00 A à 60,00 A Incertitude cour. cont., de 50 Hz à 60 Hz† ± (2,0% + 0,17 A) ± (2,0% + 0,07 A) † L’erreur induite pour les conducteurs voisins est < 0,01 A/A. Remarque : Utiliser ∆ si une correction est nécessaire avant d’effectuer la mesure. 55 Mesures types et incertitude (suite) Mesure d’intensité de courant (suite) Pince, courant alternatif et continu Hz A Intensité alternative (CM-960 et CMI-600 seulement) Incertitude de Calibre Plage de mesure 50 Hz à 100 Hz*† 0,00 A à 8,99 A ± (1,8% + 0,15 A) 60,00 A 9,00 A à 60,00 A ± (1,8% + 0,05 A) 600,0 A 60,0 A à 600,0 A ± (1,8% + 0,5 A) Incertitude de 100 Hz à 400 Hz*† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) * Le facteur de crête maximal est < 2:1 à pleine échelle et < 4:1 à mi-échelle. Intensité alternative (CM-660, CM-860, et CMH-600 seulement) Incertitude de Incertitude de Calibre Plage de mesure 50 Hz à 100 Hz*† 100 Hz à 400 Hz*† 0,00 A à 0,19 A Non spécifié Non spécifié 60,00 A 0,20 A à 5,99 A ± (1,8% + 0,15 A) ± (2,0% + 0,15 A) 6,00 A à 60,00 A ± (1,8% + 0,05 A) ± (2,0% + 0,05 A) 600,0 A 60,0 A à 600,0 A ± (1,8% + 0,5 A) ± (2,0% + 0,5 A) * Pour toute mesure, si le conducteur n’est pas placé au centre des mâchoires, ajouter 2,0 % d’incertitude pour l’erreur de position. Intensité continue (CM-960 et CMI-600 seulement) Calibre Plage de mesure 0,00 A à 8,99 A 60,00 A 9,00 A à 60,00 A 600,0 A 60,0 A à 600,0 A Intensité alt. + cont. (CM-960 et CMI-600 seulement) Incertitude de Calibre Plage de mesure 50 Hz à 100 Hz† 0,00 A à 8,99 A ± (2,2% + 0,15 A) 60,00 A 9,00 A à 60,00 A ± (2,2% + 0,05 A) 600,0 A 60,0 A à 600,0 A ± (2,2% + 0,5 A) Incertitude† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) Incertitude de 100 Hz à 400 Hz† ± (2,7% + 0,17 A) ± (2,7% + 0,07 A) ± (2,7% + 0,7 A) † L’erreur induite pour les conducteurs voisins est < 0,01 A/A. Remarque : Utiliser ∆ si une correction est nécessaire avant d’effectuer la mesure. 56 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mesures types et incertitude (suite) Mesure de résistance Résistance Calibre 600,0 Ω 6,000 kΩ 60,00 kΩ Ω Incertitude ± (1,0% + 0,5 Ω) ± (1,0% + 0,005 kΩ) ± (1,0% + 0,05 kΩ) Tension en circuit ouvert : 1,0 VDC SELECT Contrôle de continuité Continuité Seuil de tonalité : Entre 10 Ω et 250 Ω Temps de réponse : 32 ms environ SELECT Mesure de capacité Capacité (CM-860, CM-960, CMH-600, et CMI-600 seulement) Calibre 200,0 μF 2500 μF Incertitude* ± (2,0% + 0,4 μF) ± (2,0% + 4 μF) * Pour les condensateurs à couches (absorption diélectrique négligeable). Remarque : Pour les condensateurs polarisés, attacher le fil de mesure rouge à la borne positive et le fil noir à la borne négative du condensateur. 57 Mesures types et incertitude (suite) Mesure de diode Polarisation inverse Polarisation directe Contrôle de diode Calibre de mesure : 2,000 V Incertitude : ± (1,5 % + 0,005 V) Intensité de contrôle (type) : 0,3 mA Tension en circuit ouvert (type) : < 3,5 VDC SELECT Température Température (CMH-600 et CMI-600) Calibre -40,0 °C ~ 99,9 °C 100 °C ~ 400 °C -40,0 °F ~ 211,8 °F 212 °F ~ 752 °F Incertitude* ± (1,0% + 0,8 °C) ± (1,0% + 1 °C) ± (1,0% + 1,5 °F) ± (1,0% + 2 °F) * Incertitude des thermocouples de type K non incluse. Le thermocouple fourni avec l’appareil est conforme à la norme JIS C 16021981. SELECT 58 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Mesures types et incertitude (suite) 10 mm (0.4") A Champ électrique Remarque : Les modèles CM-660 et CM-860 comportent une position spécifique du sélecteur. Détection de champ électrique sans contact Tension type 20 V 55 V 110 V 220 V 440 V Plage, de 50 Hz à 60 Hz 10 V ~ 36 V 23 V ~ 83 V 59 V ~ 165 V 124 V ~ 330 V 250 V ~ 600 V Affichage ----------- Rotation de phase SELECT B A – Sans contact OU B – Avec contact, mesure de précision Rotation de moteur SELECT Clockwise Counterclockwise Sens des aiguilles Sens inverse des d’une montre aiguilles d’une montre 59 Caractéristiques techniques Affichage : Écran à cristaux liquides (LCD), 3-5/6 digits, 6 000 points Polarité : Automatique Taux de rafraîchissement : 5 par seconde (nominal) Conditions d’utilisation : 0 °C à 31 °C (32 °F à 88 °F), 0 % à 80 % d’humidité relative 31 °C à 40 °C (88 °F à 104 °F), l’humidité relative décroît linéairement de 80 % à 50 % Degré de pollution : 2 Utilisation à l’intérieur uniquement Altitude : Utilisation : en dessous de 2 000 m (6 500 ft) Température d’entreposage : -20 °C à 60 °C, humidité relative < 80 %, piles retirées Coefficient de température : Nominal 0,15 x (incertitude) par °C en dessous de 18 °C entre 0 °C et 18 °C (32 °F et 64,4 °F) ou au-dessus de 28 °C entre 28 °C et 40 °C (82,4 °F et 104 °F), sauf indication contraire Détection : Valeur efficace vraie C.E.M. : Conforme à EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) Dans un champ RF de 1 V/m à une fréquence de 405 MHz, modes intensité cont. et intensité cont. + alt. (CM-960 et CMI-960) : Incertitude totale = incertitude indiquée + 20 digits Dans un champ RF de 1 V/m, modes résistance (tous modèles) et µA cont. (CMH-600 et CMI-600) : Incertitude totale = incertitude indiquée + 25 digits Dans un champ RF de 3 V/m, tous les autres modes et modèles non spécifiés ci-dessus : Incertitude totale = incertitude indiquée + 20 digits Sécurité : Double isolation selon UL/IEC/EN61010-1 Éd. 3, IEC/EN61010-2-033 Éd. 1, CAN/CSA C22.2 n° 61010-1 Éd. 3, IEC/EN61010-2-032 Éd. 2 et IEC/EN61010-031 Éd. 1.1 jusqu’à CAT III 600 V et CAT IV 300 V alt. et cont. Protections antisurcharge : Mâchoires : Fonctions d’intensité et de fréquence : 600 A DC/AC eff. à ≤ 400 Hz Bornes : Fonctions de tension et de rotation de phase : 660 V DC/920 V AC eff. Tous autres modes et fonctions : 600 V DC/AC eff. Protection contre les transitoires : 6,0 kV (surtension de 1,2/50 μs) Alimentation : Deux piles de AAA de 1,5 V (NEDA 24A ou IEC LR03) Piles déchargées : Fonctions de capacité et de fréquence : 2,85 V environ Toutes autres fonctions : 2,5 V environ Consommation de courant : CM-960 et CMI-600 : 13 mA typique CM-660, CM-860 et CMH-600 : 4,3 mA typique Temporisation d’arrêt automatique (APO) : 32 minutes d’inactivité Consommation de l’APO : 5 μA typique Dimensions : CM-960 et CMI-600 : 222 mm x 76 mm x 37 mm (8,7” x 3,0” x 1,4”) CM-660, CM-860 et CMH-600 : 217 mm x 76 mm x 37 mm (8,5” x 3,0” x 1,4”) Ouverture de la pince et diamètre de conducteur : 30 mm max. (1,18”) 60 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Catégories de mesure Ces définitions sont dérivées des normes internationales sur la sécurité pour la ­coordination de l’isolation telle qu’elle s’applique à la mesure, au contrôle et à l’équipement de laboratoire. Ces catégories de mesure sont expliquées plus en détail par la Commission électrotechnique internationale ; se reporter à l’une de ces deux publications : IEC 61010-1 ou IEC 60664. Catégorie de mesure II Niveau local. Appareils, équipement portatif et les circuits dans lesquels ils sont branchés. Par exemple, les appareils d’éclairage, les téléviseurs et les dérivations. Catégorie de mesure III Niveau de distribution. Les machines installées en permanence et les circuits auxquels elles sont câblées. Par exemple, les systèmes de convoyeurs et les panneaux de disjoncteurs principaux du système électrique d’un édifice. Catégorie de mesure IV Niveau d’alimentation principal. Lignes surélevées et autres systèmes de câbles. Par exemple, les câbles, les compteurs, les transformateurs et autres équipements extérieurs appartenant aux fournisseurs en électricité. Déclaration de conformité Greenlee Tools, Inc. est certifiée selon ISO 9001 (2000) pour nos Systèmes de gestion de la qualité. L’instrument ci-inclus a été vérifié et/ou étalonné avec des moyens de mesure raccordés aux étalons du National Institute of Standards and Technology (NIST). 61 Entretien Risques de décharge électrique : Avant d’ouvrir le boîtier, retirer les fils d’essai du circuit et mettre l’appareil hors tension. L’inobservation de cette consigne pourrait entraîner des blessures graves, voire mortelles. Changer les piles 1. Débrancher l’appareil du circuit. Mettre l’appareil hors tension (OFF). 2. Ôter les deux vis du couvercle d’accès à la pile et enlever le couvercle. 3. Changer les piles en veillant à respecter la polarité. Nettoyage et entreposage Essuyer régulièrement le boîtier avec un chiffon humide et un détergent doux. Ne pas utiliser de produit abrasif ni de solvant. Si le multimètre doit rester inutilisé pendant des durées de plus de 60 jours, sortir les piles et les entreposer séparément. 62 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Beschreibung Die Zangenmessgeräte CM-660, CM-860, CM-960, CMH-600 und CMI-600 von Greenlee sind Handmessgeräte mit den folgenden Messfähigkeiten: Wechsel- und Gleichspannung, Wechselstrom, Wechselstrom mit AmpTip™, Frequenz, kontaktloser Nachweis eines elektrischen Feldes (EF) und Widerstand. Sie können zudem zur Überprüfung von Dioden und zur Durchgangsprüfung eingesetzt werden. Diese Messgeräte sind für isolierte und nicht isolierte Leiter ausgelegt (Anbringen/Abnehmen). Zusätzliche Funktionen der einzelnen Modelle: Funktion CMI-600 CM-960 CMH-600 CM-860 Wechsel- und Gleichspannung • • Gleichstrom mit AmpTip™ • • Gleich- und Wechselstrom mit AmpTip™ • • Gleichstrom • • Gleichstrom im µA-Bereich • • Temperatur (Thermoelement Typ K) • • Motordrehung • • Drehfeld • • Spitzen-Effektivwert-Erfassung • • • Kapazität • • • • Hintergrundbeleuchtung • • • • Zero-Modus • • • • Das Gerät bietet folgende weitere Funktionen: • Haltemodus zur Erfassung des aktuellen LCD-Werts • Aufzeichnungsmodus für Minimum, Maximum oder Durchschnitt • Intelligente Abschaltautomatik • Automatische Bereichswahl Sicherheitsvorkehrungen Sicherheitsvorkehrungen sind bei der Verwendung und der Wartung der Geräte und Ausrüstung von Greenlee entscheidend. Die vorliegende Anleitung und etwaige am Gerät angebrachte Beschriftungen geben Hinweise zur Vermeidung von Gefahren und gefährlichen Praktiken in Bezug auf die Handhabung dieses Geräts. Bitte alle hier angegebenen Sicherheitshinweise beachten. Zweck dieses Handbuchs Dieses Handbuch ist dazu vorgesehen, das Personal mit den sicheren Betriebs- und Wartungsverfahren für die Zangenmessgeräte CM-660, CM-860, CM-960, CMH-600 und CMI-600 von Greenlee vertraut zu machen. Bitte dieses Handbuch allen Mitarbeitern zugänglich machen. Ersatz-Handbücher sind auf Anfrage kostenlos erhältlich unter www.greenlee.com. 63 Wichtige Sicherheitsinformationen SICHERHEITS-WARNSYMBOL Dieses Symbol macht auf gefährliche oder riskante Praktiken aufmerksam, die zu Schäden oder Verletzungen führen können. Das Signalwort, wie nachfolgend definiert, gibt den Schweregrad der Gefahr an. Der dem Signalwort folgende Hinweis informiert darüber, wie die Gefahr verhindert oder vermieden wird. Akute Gefahr, die bei Nichtvermeiden zu schweren Verletzungen oder zum Tod FÜHRT. Gefahr, die bei Nichtvermeiden zu schweren Verletzungen oder zum Tod führen KANN. Gefahr oder unsichere Praktiken, die bei Nichtvermeiden zu Verletzungen oder Sachschäden führen KÖNNEN. Vor Betrieb oder Wartung dieses Geräts die Bedienungsanleitung sorgfältig durchlesen und beachten. Mangelndes Verständnis der sicheren Betriebsweise dieses Geräts kann zu Unfällen mit schweren oder tödlichen Verletzungen führen. Stromschlaggefahr: Das Berühren von Stromkreisen kann zu schweren Verletzungen oder zum Tod führen. Dieses Produkt nicht wegwerfen. Recycling-Informationen sind unter www.greenlee.com nachzulesen. Alle technischen Daten sind Nennwerte. Bei Designverbesserungen sind Änderungen der Nennwerte vorbehalten. Greenlee Tools, Inc. haftet nicht für Schäden, die sich aus der falschen Anwendung oder dem Missbrauch seiner Produkte ergeben. ® Eingetragen: Die Farbe Grün für elektrische Testgeräte ist eine eingetragene Marke von Tools, Innovations Inc. AmpTip ist eine Marke von BTC. DIESES HANDBUCH UNBEDINGT AUFBEWAHREN 64 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Wichtige Sicherheitsinformationen Stromschlag- und Brandgefahr: • Dieses Gerät darf weder Regen noch Feuchtigkeit ausgesetzt werden. • Das Gerät nicht benutzen, wenn es nass oder beschädigt ist. • Zangenmessgerät, Messleitungen und alles andere Zubehör gelten als ein System, wenn sie zusammen zur Messung verwendet werden. Das System ist bei Verwendung der im Lieferumfang des Messgeräts enthaltenen Messleitungen und Zubehörteile für Stromkreise CAT III 600 V oder CAT IV 300 V ausgelegt. Bei Verwendung von nicht mit dem Messgerät gelieferten Messleitungen oder Zubehörteilen basiert die Systemauslegung in Bezug auf CAT und Spannung auf der Komponente mit der niedrigsten Auslegung im System. • Vor dem Einsatz die Messleitungen oder Zubehörteile überprüfen. Sie müssen sauber und trocken und die Isolation muss in einem guten Zustand sein. Messleitungen dürfen nicht verwendet werden, wenn die kontrastierende innere Isolierung sichtbar ist. • Dieses Gerät darf nur zu seinem vom Hersteller bestimmten Zweck wie in dieser Anleitung beschrieben verwendet werden. Davon abweichende Verwendungszwecke beeinträchtigen u.U. den vom Gerät gebotenen Schutz. Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen Verletzungen führen. Stromschlaggefahr: • Zwischen zwei Eingangsanschlüssen bzw. einem Eingangsanschluss und der Erdung nicht mehr als die Nennspannung anlegen. • Darauf achten, dass Hände und Finger unterhalb der Schutzbarrieren an den Messleitungen und am Messgerätgehäuse bleiben. Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen Verletzungen führen. Stromschlaggefahr: • Das Gerät nicht mit offenem Gehäuse benutzen. • Vor dem Öffnen des Gehäuses die Messleitungen vom Stromkreis entfernen und das Gerät ausschalten. Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen Verletzungen führen. 65 Wichtige Sicherheitsinformationen Stromschlaggefahr: • Das Gerät ausschalten und die Stromzufuhr blockieren, wenn es nicht zur Messung von Stromstärke, der Spannung oder Frequenz eingesetzt wird. Darauf achten, dass alle Kondensatoren entladen sind. Es darf keine elektrische Spannung vorhanden sein. • Den Wahlschalter gemäß der vorzunehmenden Messung einstellen und die Messleitungen entsprechend anschließen. Falsche Einstellungen oder falsches Anlegen können zu Messfehlern oder Geräteschäden führen. • Die Verwendung dieses Geräts in der Nähe von Anlagen, die elektromagnetische Störungen hervorrufen, kann zu instabilen bzw. ungenauen Messwerten führen. Das Nichtbeachten dieser Warnungen könnte zu schweren oder tödlichen Verletzungen führen. Stromschlaggefahr: • Bei an einer Komponente oder einem Stromkreis angeschlossenen Messleitungen darf die Messfunktion nicht geändert werden. • Die Zange darf nicht an einen Leiter angelegt werden, der eine Frequenz über 400 Hz führt. Bei Überschreitung dieser Frequenz können die Magnetschaltkreise gefährliche Temperaturen entwickeln. Nichtbeachten dieser Sicherheitsvorkehrungen kann zu Verletzungen oder Schäden am Gerät führen. Stromschlaggefahr: • An diesem Gerät keine Reparaturen vornehmen. Es enthält keine Teile, die vom Benutzer gewartet werden können. • Das Gerät keinen extremen Temperaturen oder hoher Luftfeuchtigkeit aussetzen. Siehe „Technische Daten“. Nichtbeachten dieser Sicherheitsvorkehrungen kann zu Verletzungen oder Schäden am Gerät führen. 66 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Bezeichnungen 1. Antenne für berührungslosen Nachweis eines elektrischen Feldes (EF) 2. Zangenmittenanzeige für optimale Genauigkeit; Polaritätsanzeige für Gleichstrom 3. Zur Auswahl einer Funktion oder zum Ausschalten des Geräts 4. LCD 5. Eingangsbuchsen – nur für Drehfeld und Motordrehung 6. Eingangsanschluss (+); Eingang L2 für Drehfeld und Motordrehung 7. Eingangsanschluss (– , Masse, Erde); Eingang L1 für Drehfeld und Motordrehung 8. Siehe Erläuterungen unter „Einsatz der Funktionen“. 9. Zangenhebel 10. Hände und Finger sind während des Betriebs unterhalb der Strichellinie zu halten. 11. Zange 12. Mittenanzeige für AmpTip™ Funktion 12 1 11 2 10 9 3 4 8 7 5 6 Symbole am Gerät Warnhinweis – Bedienungsanleitung lesen Warnung – Stromschlaggefahr Erde Doppelisolierung AC (Wechselstrom) DC (Gleichstrom) Anlegen an bzw. Abnehmen von stromführenden Leitern mit gefährlichen Spannungen ist zulässig. 67 Anzeigesymbole 1. 2. 3. 4. 5. 6. 7. 8. 8.8.8.8 9. µ 10. F 11. A 12. V 13. Hz 14. Ω 15. k 16. 17. ∆ 18. – 19. VFD 20. 21. 22. 23. 24. 25. 26. 27. + MAX MIN AVG Automatische Bereichswahl ist aktiviert. Aufzeichnungs-Funktion ist aktiviert Diode Durchgang Spitzen-Effektivwert-Modus ist aktiviert. Drehfeld Netzstromversorgung Motordrehung Numerische Anzeige Mikro (10-6) Farad Ampere Volt Hertz (Frequenz in Taktzyklen pro Sekunde) Ohm Kilo (103) AmpTip™-Funktion ist aktiviert. Funktion „Relative Zero“ (Relativer Nullpunkt) ist aktiviert. Polaritätsanzeige Wechselstrommessung mit Filter zur genauen Messung bei variablen Frequenzantrieben AC-Messung ist ausgewählt. AC- und DC-Messung ist ausgewählt. DC-Messung ist ausgewählt. Niedriger Batteriestand Halte-Funktion ist ausgewählt. Maximaler Messwert wird angezeigt. Minimaler Messwert wird angezeigt. Durchschnittswert wird angezeigt. 1 2 3 4 5 28 21 19 23-27 22 6-7 20 8 18 17 9-12 16 68 15 14 13 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Einsatz der Funktionen Alle Modelle • REC (AUFZEICHNUNG): Diese Taste kurz drücken, um den MAX/MIN/AVGAufzeichnungsmodus zu aktivieren. und „MAX MIN AVG“ erscheinen dann auf der Anzeige. Bei Aktualisierung des Minimal- bzw. Maximalwertes gibt das Messgerät ein Tonsignal ab. Der Durchschnittswert wird über einen Zeitraum berechnet. Die Taste kurz drücken, um die Messewerte für MAX, MIN und AVG nacheinander anzuzeigen. Diese Taste eine Sekunde lang drücken, um den MAX/MIN/AVG-Aufzeichnungsmodus zu aktivieren. Die Abschaltautomatik (APO) ist in diesem Modus automatisch deaktiviert. • SELECT (AUSWÄHLEN): Kurz drücken, um zu den verschiedenen Funktionen, Messarten oder Anzeigemodi umzuschalten. Die letzte verwendete Einstellung wird zur Standardeinstellung, wenn diese Funktion erneut gewählt wird. Zur Änderung der Standardeinstellung eine neue Einstellung wählen. Die Einstellung wird im nichtflüchtigen Speicher gespeichert. • HOLD (HALTEN): Kurz drücken, um den aktuellen Messwert auf der Anzeige zu halten. Nochmals drücken, um diesen Modus zu beenden. • Intelligente Abschaltautomatik (APO): Das Messgerät schaltet sich nach ungefähr 32 Minuten Inaktivität aus, um die Nutzungsdauer der Batterie zu verlängern. Die aktive Messgerätefunktion wird wie folgt definiert: Auswahlschalter wird gedreht, Tasten werden gedrückt; Messungen von über 8,5 % des Bereichs; nicht auf die Überlast (OL) bezogene Messungen für Widerstand, Durchgang oder Diodenfunktion; Messwerte ungleich null für die Hz-Funktion; Drehfeld-Segment in Bewegung. Um das Messgerät nach einer automatischen Abschaltung wieder zu aktivieren, die Taste SELECT (AUSWÄHLEN) kurz drücken oder den Wahlschalter auf OFF (AUS) drehen und dann wieder einschalten. Den Drehschalter grundsätzlich auf OFF (AUS) drehen, wenn das Messgerät nicht in Gebrauch ist. Nur für CM-860, CM-960, CMH-600 und CMI-600 : Die Taste SELECT (AUSWÄHLEN) eine Sekunde lang drücken, um die LCDHintergrundbeleuchtung ein- und auszuschalten. Die Hintergrundbeleuchtung schaltet sich nach 32 Sekunden aus, um die Nutzungsdauer der Batterie zu verlängern. • ∆: Die Taste ∆ eine Sekunde lang drücken, um zwischen den Modi Zero und Normal umzuschalten. Im Zero-Modus wird der beim Drücken der Taste auf der LCD-Anzeige angezeigte Wert als Offset-Wert festgelegt. Bei einer Änderung des Eingangswerts wird die Verschiebung vom Istwert abgezogen. Dieser abgeänderte Wert erscheint auf der LCD-Anzeige. Hinweis: ∆ Betrieb, wenn Funktion DCA oder DC + ACA ausgewählt wird, wird die magnetische Hysterese in der Zange ausgeglichen. Wenn der Wert für DCA oder DC + ACA vor der Messung nicht null ist, die Taste ∆ eine Sekunde lang drücken. Auf der LCD-Anzeige wird „dc_0“ eingeblendet. Wenn diese Anzeige erlischt, ist das Messgerät betriebsbereit. Wenn mehr als 5 A gemessen werden, ist dieser Modus deaktiviert. Das Messgerät gibt drei Signaltöne ab, um darauf aufmerksam zu machen. • Nur für CM-960, CMH-600 und CMI-600 • PEAK-RMS (SPITZEN-EFFEKTIVWERT): Die Taste PEAK-RMS (SPITZENEFFEKTIVWERT) eine Sekunde lang drücken, um den PEAK-RMS-Modus zur Erfassung des Spitzenstroms bzw. der Spitzenspannung ab 80 ms Dauer zu aktivieren. wird auf der Anzeige eingeblendet. Die Taste eine Sekunde lang drücken, um den Modus PEAK-RMS (SPITZEN-EFFEKTIVWERT) zu verlassen. Die Abschaltautomatik (APO) ist in diesem Modus automatisch deaktiviert. 69 Einsatz der Funktionen (Fortsetzung) Nur für CMH-600 und CMI-600 • und : Falls gewünscht, die Taste REC (AUFZEICHNUNG) gedrückt halten und dabei das Messgerät einschalten, um das akustische Signal zu aktivieren. Wenn die Segmente eine Drehung im Uhrzeigersinn anzeigen, ertönt ein einzelner langer Signalton pro Segmentzyklus. Wenn die Segmente eine Bewegung entgegen dem Uhrzeigersinn anzeigen, ertönen drei kurze Signaltöne pro Segmentzyklus. • : Sicherstellen, dass der Motor von seiner Stromversorgung elektrisch isoliert ist. Die Taste SELECT (AUSWÄHLEN) kurz drücken, um die Motorfunktion auszuwählen. Das Messgerät entsprechend den Anweisungen in der „Tabelle der Einstellungen“ in diesem Handbuch an den Motor anlegen. Den Motor im Uhrzeigersinn drehen (Blickrichtung entlang der Motorwelle). Wenn das Messgerät eine Drehung im Uhrzeigersinn anzeigt, sind die an L1, L2 und L3 des Messgeräts angeschlossenen Motorleitungen T1, T2 bzw. T3. Wenn das Messgerät eine Drehung entgegen dem Uhrzeigersinn anzeigt, zwei beliebige Anschlüsse zwischen Messgerät und Motor vertauschen und erneut prüfen. • : Die Taste SELECT (AUSWÄHLEN) kurz drücken, um die Drehfeldfunktion auszuwählen. Das Messgerät entsprechend den Anweisungen in der „Tabelle der Einstellungen“ in diesem Handbuch an die Phasen anlegen. Wenn das Messgerät eine Drehung im Uhrzeigersinn anzeigt, sind die an L1, L2 und L3 des Messgeräts angeschlossenen Phasen L1, L2 bzw. L3. Wenn das Messgerät eine Drehung entgegen dem Uhrzeigersinn anzeigt, zwei beliebige Anschlüsse zwischen Messgerät und Phasen vertauschen und erneut prüfen. Verwendung der Messleitungen Stromschlaggefahr: Die im Lieferumfang dieses Produkts enthaltenen Messleitungen entsprechen den Sicherheitsstandards, die die freiliegende Länge der Sondenspitze für die Messkategorien III und IV auf 4 mm beschränken. Zu diesen Messleitungen gehört eine Kappe, die für Anwendungen der Messkategorie III bzw. IV aufgesetzt sein muss. Das Nichtbeachten dieser Warnung kann zu schweren oder tödlichen Verletzungen führen. Für Anwendungen der Messkategorie III oder IV muss die Kappe aufgesetzt sein. Für Anwendungen der Messkategorie I oder II kann sie jedoch abgenommen werden. 70 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Wechselstrommessung Wechselstrommessungen werden normalerweise als Effektivwerte (RMS, quadratischer Mittelwert) angezeigt. Der Effektivwert entspricht dem Wert einer Gleichstromwellenform, die dieselbe Stromleistung liefern würde, als wenn sie die zeitlich-veränderliche Wellenform ersetzen würde. Die beiden Wechselstrommessmethoden sind: den Mittelwert ermittelnde, auf den Effektivwert kalibrierte Messung und Echteffektivwert-Messung. Bei der Methode „den Mittelwert ermittelnde, auf den Effektivwert kalibrierte Messung“ wird der Mittelwert des Eingangssignals nach kompletter Gleichrichtung der Wellen mit 1,11 multipliziert und das Ergebnis angezeigt. Diese Methode ist genau, wenn es sich bei dem Eingangsignal um eine reine Sinuswelle handelt. Bei der Echteffektivwertmessmethode kommt zum Ablesen des echten Effektivwerts ein innerer Schaltkreis zum Einsatz. Diese Methode ist im Rahmen der angegebenen Crestfaktor-Beschränkungen genau, gleich, ob es sich bei dem Eingangssignal um eine reine Sinus-, Rechteck-, Dreieck- oder Halbwelle bzw. ein Signal mit Oberschwingungen handelt. Die Möglichkeit, den Echteffektivwert abzulesen, bietet vielseitigere Messmöglichkeiten. Bei den Modellen CM-660, CM-860, CM-960, CMH-600 und CMI-600 von Greenlee handelt es sich um Echteffektivwert-Messgeräte. In der Tabelle „Wellenformen und Crestfaktoren“ sind einige typische Wechselstromsignale und deren Effektivwerte angegeben. Wellenformen und Crestfaktoren Wellenform Effektivwert 100 100 100 100 Durchschnittswert 90 100 87 64 Crestfaktor* (x) 1,414 1 1,73 2 * Bei dem Crestfaktor handelt es sich um das Verhältnis des Spitzenwertes (auch Scheitelwertes) zum Effektivwert und wird durch den griechischen Buchstaben x dargestellt. AC + DC Echteffektivwert Mit AC + DC Echteffektivwert werden die beiden Wechselstrom- und Gleichstromkomponenten bei der Messung mithilfe der folgenden Formel bestimmt: Das Gerät reagiert ungeachtet der Wellenform fehlerfrei auf den gesamten Effektivwert. Verzerrte Wellenformen mit vorhandenen DC-Komponenten und Oberschwingen können Folgendes verursachen: • Überhitzung von Transformatoren, Generatoren und Motoren • Frühzeitige Auslösung von Schutzschaltern • Durchbrennen von Sicherungen • Überhitzung von Nullleitern aufgrund von auf dem Nullleiter vorhandenen harmonischen Triplen • Vibration der Stromschiene und der Elektroschalttafeln Die Modelle CM-960 und CMI-600 können so eingestellt werden, dass sie entweder den AC-Echteffektivwert oder AC- + DC-Echteffektivwert anzeigen. 71 AC-Bandbreite Bei der AC-Bandbreite handelt es sich um den Frequenzbereich, in dem AC-Messungen mit der angegebenen Genauigkeit vorgenommen werden können. Es ist die Frequenzreaktion der AC-Funktionen – nicht die der Frequenzmessungsfunktionen. Ein Messgerät kann den AC-Wert mit Frequenzspektren außerhalb seiner Bandbreite nicht genau bestimmen. Komplexe Wellenformen, Rauschen und verzerrte Wellenformen enthalten Frequenzkomponenten, die sehr viel höher sind als die Fundamentalschwingung. Beispiel: hochfrequentes Rauschen auf einer 50/60 Hz-Freileitung. Betrieb Stromschlaggefahr: Das Berühren von Stromkreisen kann zu schweren Verletzungen oder zum Tod führen. Bedienungsanweisung 1. Siehe „Tabelle der Einstellungen“. Den Wahlschalter auf die richtige Einstellung drehen, (bei Aufforderung) SELECT (AUSWÄHLEN) drücken und dann die Messleitungen am Messgerät anschließen. 2. Siehe „Typische Messungen“ für spezifische Messanleitungen. 3. Das Gerät an einem funktionierenden Stromkreis oder einer funktionsfähigen Komponente testen. • Wenn das Messgerät an einem funktionierenden Stromkreis nicht wie erwartet funktioniert, die Batterien austauschen. • Wenn das Messgerät anschließend immer noch nicht wie erwartet funktioniert, unter der Rufnummer +1-815-397-7070 Kontakt mit dem technischen Kundendienst von Greenlee aufnehmen. 4. Den Messwert von dem zu testenden Stromkreis oder der zu testenden Komponente ablesen. 72 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Betrieb (Fortsetzung) Tabelle der Einstellungen Zur Messung von … den Die Diese Symbole Die rote Wahlschalter schwarze erscheinen Messleitung auf dieses Messleitung dann in der anschließen Symbol anschließen Anzeige … an … stellen … an … ALLE MODELLE Spannung (AC) V + COM Spannung (DC) V + COM Strom, AmpTip™ (AC) A nicht zutr. nicht zutr. Strom (AC) A nicht zutr. nicht zutr. + COM + COM + COM + COM nicht zutr. COM Ω Durchgang Widerstand Ω kΩ V Diode Frequenz Elektrisches Feld (EF)* Hz EF Hz EF Nur für CM-860, CM-960, CMH-600 und CMI-600 µF Kapazität** + COM + COM Nur für CM-960 und CMI-600 Spannung (AC + DC) Strom, AmpTip™ (DC) A nicht zutr. nicht zutr. Strom, AmpTip™ (AC + DC) A nicht zutr. nicht zutr. Strom (DC) A nicht zutr. nicht zutr. Strom (AC + DC) A nicht zutr. nicht zutr. Nur für CMH-600 und CMI-600 Temperatur Strom (µA DC) Temp C oder F µA *** + COM Drehfeld† + COM Motordrehung† + COM * Die Oberseite der stationären Zangenbacke verwenden oder, für noch genauere Messungen, eine Sonde im COM-Anschluss. ** Den Kondensator vor der Messung entladen. Weitere Informationen zu polarisierten Kondensatoren sind unter „Typische Messungen“ zu finden. *** Thermoelement + wird an + angeschlossen, Thermoelement – wird an COM angeschlossen. † Die gelbe Leitung wird an L3 angeschlossen. 73 Typische Messungen und Messgenauigkeit Informationen zu den Betriebsbedingungen und zum Temperaturkoeffizienten sind im Abschnitt „Technische Daten“ zu finden. Die Messgenauigkeit ist wie folgt angegeben: ± (ein Prozentsatz des Messwerts + ein fester Betrag) bei 23 °C ± 5 °C (73,4 °F ± 9 °F). Bei nicht sinusförmigen Wellenformen muss die Frequenz innerhalb der angegebenen Bandbreite liegen. Die Crestfaktoren sind, falls nicht anders angegeben, wie folgt: • Crestfaktor < 2,5:1 bei Maßstab 1:1 • Crestfaktor < 5,0:1 bei Maßstab 1:2 Frequenz Funktion 600 V 60,0 A AmpTip™ 60,00 A, 600,0 A Empfindlichkeit (Sinussignal-Effektivwert)* 50 V 40 A 40 A Bereich 5,00 Hz ~ 999,9 Hz 50,00 Hz ~ 400,0 Hz 50,00 Hz ~ 400,0 Hz * Die DC-Vorspannung muss <50 % des Sinussignal-Effektivwerts sein. Genauigkeit des Frequenzbereichs Anzeigebereich xx.xx xxx.x Messgenauigkeit ± (1,0% + 0,05 Hz) ± (1,0% + 0,5 Hz) Spannungsmessung EF Hz V VFD VFD SELECT Wechselspannung Messgenauigkeit Bereich bei 50 Hz bis 60 Hz Gleichspannung Wechsel- und Gleichspannung (nur für (CM-960 und CMI-600) Bereich Messgenauigkeit 600,0 ± (1,0% + 0,5 V) 600,0 ± (1,0% + 0,5 V) Eingangsimpedanz: 10 MΩ, 100 pF nominal 74 SELECT Bereich Messgenauigkeit bei Gleichspannung, 50 Hz bis 60 Hz 600,0 ± (1,2% + 0,7 V) CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typische Messungen und Messgenauigkeit (Fortsetzung) Strommessung DC µA Flame Sensor Flammenwächter µA Pilot Flame Zündflamme Control Steuerplatine Board μDC Strom (nur für CMH-600 und CMI-600) Bereich 200,0 μA 2000 μA AmpTip™ Funktion Messgenauigkeit ± (1,0% + 0,5 μA) ± (1,0% + 5 μA) Bürdenspannung 3,5 mV/μA AmpTip™ Wechselstrom Bereich Messgenauigkeitsbereich Messgenauigkeit bei 50 Hz bis 60 Hz** 60,00 A < 0,20 A* 0,00 A bis 3,99 A 4,00 A bis 60,00 A Nicht angegeben ± (1,5% + 0,15 A) ± (1,5% + 0,05 A) * Nur für CM-660, CM-860 und CMH-600. ** Nur für CM-960 und CMI-600: Der Induktionsfehler für benachbarte stromführende Leiter ist <0,01 A/A. Hz A AmpTip™ Gleichstrom (nur für CM-960 und CMI-600) Bereich Messgenauigkeitsbereich Messgenauigkeit† 60,00 A 0,00 A bis 3,99 A 4,00 A bis 60,00 A ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) AmpTip™ Gleich- und Wechselstrom (nur für CM-960 und CMI-600) Bereich Messgenauigkeitsbereich Messgenauigkeit bei Gleichspannung, 50 Hz bis 60 Hz† 60,00 A 0,00 A bis 3,99 A 4,00 A bis 60,00 A ± (2,0% + 0,17 A) ± (2,0% + 0,07 A) † Der Induktionsfehler für benachbarte stromführende Leiter ist <0,01 A/A. Hinweis: ∆ drücken, falls vor der Messung ein Wert angezeigt wird, der dann als Offset-Wert abgezogen wird. 75 Typische Messungen und Messgenauigkeit (Fortsetzung) Strommessung (Fortsetzung) Zange für Wechselund Gleichstrom Hz A Wechselstrom (nur für CM-960 und CMI-600) Messgenauigkeits- Messgenauigkeit bei Bereich bereich 50 Hz bis 100 Hz*† 0,00 A bis 8,99 A ± (1,8% + 0,15 A) 60,00 A 9,00 A bis 60,00 A ± (1,8% + 0,05 A) 600,0 A 60,0 A bis 600,0 A ± (1,8% + 0,5 A) Messgenauigkeit bei 100 Hz bis 400 Hz*† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) * Maximaler Crestfaktor <2:1 bei Maßstab 1:1 und <4:1 bei Maßstab 1:2. Wechselstrom (nur für CM-660, CM-860 und CMH-600) Messgenauigkeits- Messgenauigkeit bei Bereich bereich 50 Hz bis 100 Hz*† 0,00 A bis 0,19 A Nicht angegeben 60,00 A 0,20 A bis 5,99 A ± (1,8% + 0,15 A) 6,00 A bis 60,00 A ± (1,8% + 0,05 A) 600,0 A 60,0 A bis 600,0 A ± (1,8% + 0,5 A) Messgenauigkeit bei 100 Hz bis 400 Hz*† Nicht angegeben ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) * Bei allen Messungen, bei denen der Leiter nicht mittig in der Zange positioniert ist, müssen 2,0 % aufgrund des Positionsfehlers zur Toleranz addiert werden. Gleichstrom (nur für CM-960 und CMI-600) MessgenauigkeitsBereich bereich 0,00 A bis 8,99 A 60,00 A 9,00 A bis 60,00 A 600,0 A 60,0 A bis 600,0 A Wechsel- und Gleichstrom (nur für CM-960 und CMI-600) Messgenauigkeits- Messgenauigkeit bei Bereich bereich 50 Hz bis 100 Hz† 0,00 A bis 8,99 A ± (2,2% + 0,15 A) 60,00 A 9,00 A bis 60,00 A ± (2,2% + 0,05 A) 600,0 A 60,0 A bis 600,0 A ± (2,2% + 0,5 A) Messgenauigkeit† ± (2,0% + 0,15 A) ± (2,0% + 0,05 A) ± (2,0% + 0,5 A) Messgenauigkeit bei 100 Hz bis 400 Hz† ± (2,7% + 0,17 A) ± (2,7% + 0,07 A) ± (2,7% + 0,7 A) † Der Induktionsfehler für benachbarte stromführende Leiter ist <0,01 A/A. Hinweis: ∆ drücken, falls vor der Messung ein Wert angezeigt wird, der dann als OffsetWert abgezogen wird. 76 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typische Messungen und Messgenauigkeit (Fortsetzung) Widerstandsmessung Widerstand Bereich 600,0 Ω 6,000 kΩ 60,00 kΩ Ω Messgenauigkeit ± (1,0% + 0,5 Ω) ± (1,0% + 0,005 kΩ) ± (1,0% + 0,05 kΩ) Leerlaufspannung: 1,0 V DC SELECT Durchgangsprüfung Durchgang Signal-Schwellenwert: Zwischen 10 Ω und 250 Ω Ansprechzeit: ca. 32 ms SELECT Kapazitätsmessung Kapazität (nur für CM-860, CM-960, CMH-600 und CMI-600) Bereich 200,0 μF 2500 μF Messgenauigkeit* ± (2,0% + 0,4 μF) ± (2,0% + 4 μF) * Für Schichtkondensatoren (Kondensatoren mit vernachlässigbarer dielektrischer Absorption) Hinweis: Bei polarisierten Kondensatoren die rote Sonde an den positiven Anschluss und die schwarze Sonde an den negativen Anschluss des Kondensators anschließen. 77 Typische Messungen und Messgenauigkeit (Fortsetzung) Diodenmessung Sperrvorspannung Durchlassspannung Diodentest Messbereich: 2000 V Messgenauigkeit: ± (1,5 % + 0,005 V) Prüfstrom (typisch): 0,3 mA Leerlaufspannung (typisch): <3,5 V DC SELECT Temperatur Temperatur (nur für CMH-600 und CMI-600) Bereich -40,0 °C ~ 99,9 °C 100 °C ~ 400 °C -40,0 °F ~ 211,8 °F 212 °F ~ 752 °F Messgenauigkeit* ± (1,0% + 0,8 °C) ± (1,0% + 1 °C) ± (1,0% + 1,5 °F) ± (1,0% + 2 °F) * Messgenauigkeit des Thermoelements vom Typ K nicht aufgeführt. Das im Lieferumfang des Messgeräts enthaltene Thermoelement entspricht der Norm JIS C 1602 1981. SELECT 78 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Typische Messungen und Messgenauigkeit (Fortsetzung) 10 mm (0.4") A Elektrisches Feld Hinweis: CM-660 und CM-860 haben eine dedizierte Schalterposition. Berührungsloser Nachweis eines elektrischen Feldes (EF) Typische Bereich bei Spannung 50 Hz bis 60 Hz 20 V 10 V ~ 36 V 55 V 23 V ~ 83 V 110 V 59 V ~ 165 V 220 V 124 V ~ 330 V 440 V 250 V ~ 600 V LCDAnzeige ----------- Drehfeld SELECT B A – Kontaktlos ODER B – Kontakt, Präzisionsmessung Motordrehung SELECT Clockwise Im Uhrzeigersinn Counterclockwise Entgegen dem Uhrzeigersinn 79 Technische Daten Anzeige: LCD, 3 5/6 Stellen mit maximal 6000 Punkten Polarität: Automatisch Aktualisierungsrate: 5 pro Sekunde, Nennwert Betriebsbedingungen: 0 °C bis 31 (32 °F bis 88 °F), 0 % bis 80 % relative Luftfeuchtigkeit 31 °C bis 40 (88°F bis 40,00 ), relative Luftfeuchtigkeit verringert sich linear von 80 % auf 50 % Verschmutzungsgrad: 2 Nur in Innenräumen verwenden Höhe über NN: Betrieb unterhalb 2000 m (6500 ft) Lagertemperatur: -20 °C bis 60 °C, relative Luftfeuchtigkeit <80 %, mit entnommenen Batterien Temperaturkoeffizient: Nennwert 0,15 x (Genauigkeit) pro Grad C unter 18 °C von 0 °C bis 18 °C (32 °F bis 64,4 °F) und über 28 °C von 28 °C bis 40 (82,4 °F bis 104 °F) oder anderweitig angegeben Messung: Echteffektivwert EMV: Entspricht EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In einem RF-Feld von 1 V/m bei Frequenzen von 405 MHz, Modi DCA und DC+AC A (CM-960 und CMI-960): Messgenauigkeit gesamt: angegebene Genauigkeit +20 Stellen In einem RF-Feld von 1 V/m, Widerstandsmodi (alle Modelle) und Modus DC µA (CMH-600 und CMI-600): Messgenauigkeit gesamt: angegebene Genauigkeit +25 Stellen In einem RF-Feld von 3 V/m, alle anderen Modi sowie oben nicht angegebenen Modelle: Messgenauigkeit gesamt: angegebene Genauigkeit +20 Stellen Sicherheitsvorkehrungen: Doppelisolierung gemäß UL/IEC/EN61010-1 Version 3, IEC/ EN61010-2-033 Version 1, CAN/CSA C22.2 Nr. 61010-1 Version 3, IEC/EN61010-2-032 Version 2 und IEC/EN61010-031 Version 1.1 nach CAT III 600V und CAT IV 300V AC und DC Überlastschutz: Zange: Strom- mit Frequenzfunktion: 600 A DC/AC Effektivwert bei ≤400 Hz Eingänge: Spannungs- und Drehfeld-Funktion: 660 V DC/920 V AC Effektivwert Alle anderen Modi und Funktionen: 600 V DC/AC Effektivwert Stoßspannungsschutz: 6,0 kV (Stoßspannung von 1,2/50 μs) Stromversorgung: Zwei 1,5-V-AAA-Batterien (NEDA 24A oder IEC LR03) Niedriger Batteriestand: Kapazitäts- und Frequenzfunktion: Ca. 2,85 V Alle anderen Funktionen: Ca. 2,5 V Stromaufnahme: CM-960 und CMI-600: Normalerweise 13 mA CM-660, CM-860 und CMH-600: Normalerweise 4,3 mA Wartezeit für Abschaltautomatik (APO): 32 Minuten Inaktivität APO-Stromaufnahme: 5 μA typischer Wert Abmessungen: CM-960 und CMI-600: 222 mm x 76 mm x 37 mm (8,7” x 3,0” x 1,4”) CM-660, CM-860 und CMH-600: 217 mm x 76 mm x 37 mm (8,5” x 3,0” x 1,4”) Zangenöffnung und Leiterdurchmesser: Max. 30 mm (1,18”) 80 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Messkategorien Diese Definitionen stammen aus den internationalen Sicherheitsnormen für Isolierungen – abgestimmt auf die Anwendbarkeit bei Mess-, Steuer- und Laborgeräten. Genauere Beschreibungen dieser Messkategorien sind in den beiden folgenden Veröffentlichungen der International Electrotechnical Commission zu finden: IEC 61010-1 oder IEC 60664. Messkategorie II Lokalebene. Haushaltgeräte, tragbare Geräte und die Stromnetze, an denen sie angeschlossen sind. Dazu gehören beispielsweise Lampen, Fernsehgeräte und lange Abzweigkreise. Messkategorie III Verteilungsebene. Fest installierte Maschinen und die Netze, an denen sie fest angeschlossen sind. Dazu gehören beispielsweise Förderanlagen und die Hauptstromunterbrechungs-Schalttafeln der elektrischen Anlage eines Gebäudes. Messkategorie IV Primärversorgungsebene. Freileitungen und andere Kabelsysteme. Dazu gehören beispielsweise Kabel, Elektrizitätszähler, Transformatoren und sonstige Anlagen im Freien, die der Stromversorgungsgesellschaft gehören. Konformitätserklärung Greenlee Tools, Inc. ist für seine Qualitätsverwaltungssysteme gemäß ISO 9001:2008 zertifiziert. Das gelieferte Gerät wurde mit Betriebsmitteln überprüft bzw. kalibriert, die zum National Institute for Standards and Technology (NIST) rückführbar sind. 81 Wartung Stromschlaggefahr: Vor dem Öffnen des Gehäuses die Messleitungen vom Stromkreis entfernen und das Gerät ausschalten. Das Nichtbeachten dieser Warnung könnte zu schweren oder tödlichen Verletzungen führen. Auswechseln der Batterien 1. Das Gerät vom Netz trennen. Das Gerät AUSSCHALTEN. 2. Die beiden Schrauben aus dem Batteriefachdeckel herausdrehen und den Deckel abnehmen. 3. Beim Auswechseln der Batterien die Polarität der Batterien beachten. Reinigen und Lagerung Das Gehäuse regelmäßig mit einem feuchten Tuch und einem milden Reinigungsmittel abwischen. Keine Scheuer- oder Lösungsmittel verwenden. Soll das Messgerät länger als 60 Tage nicht verwendet werden, die Batterien herausnehmen und getrennt vom Gerät aufbewahren. 82 CM-660 • CM-860 • CM-960 • CMH-600 • CMI-600 Lifetime Limited Warranty Greenlee Tools, Inc. warrants to the original purchaser of these goods for use that these p­ roducts will be free from defects in workmanship and material for their useful life, excepting normal wear and abuse. This warranty is subject to the same terms and conditions contained in Greenlee Tools, Inc.’s standard one-year limited warranty. For all Test Instrument repairs, contact Customer Service at 800-435-0786 and request a Return Authorization. For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote is available upon request. Note: Prior to returning any test instrument, please check replaceable b­ atteries or make sure the battery is at full charge. Garantía limitada válida durante la vida útil del producto Greenlee Tools, Inc. le garantiza al comprador original de estos bienes de uso, que los mismos estarán libres de defectos de materiales y fabricación durante su vida útil, excepto en el caso de que sean maltratados o hayan sufrido el deterioro normal. Esta garantía está sujeta a los mismos términos y condiciones de la garantía estándar limitada válida por un año, otorgada por Greenlee Tools, Inc. Para reparaciones de todo instrumento de verificación, comuníquese con el Departamento de Servicio al Cliente al 800-435-0786 y solicite una autorización de devolución. Puede obtener, previa solicitud, una cotización de precios de reparación para aquellos artículos que no están cubiertos bajo esta garantía (los que se han dejado caer o han sido maltratados). Aviso: Antes de devolver un instrumento de verificación, revise si las baterías están bajas y es necesario reemplazarlas. Garantie à vie limitée La société Greenlee Tools, Inc. garantit à l’acheteur d’origine de ces produits que ces derniers ne comportent aucun défaut d’exécution ou de matériau pour la durée de leur vie utile, sauf l’usure normale. Cette garantie est assujettie aux mêmes conditions que celles contenues dans les modalités et conditions de la garantie limitée standard d’un an de Greenlee Tools, Inc. Pour toutes les réparations d’instruments de mesure, appeler le service après vente au 800 435-0786 et demander une autorisation de retour. Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil tombe, s’il est soumis à un usage abusif, etc.), une soumission pour le prix de réparation sera présentée sur demande. Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier les piles remplaçables ou vous assurer que la batterie est ­complètement chargée. Lebenslange beschränkte Garantie Greenlee Tools, Inc. garantiert dem Erstkäufer dieser Produkte, dass sie unter Ausschluss von normalem Verschleiß oder Missbrauch für den Zeitraum ihrer Nutzungsdauer frei von Bearbeitungs- und Materialfehlern sind. Diese Garantie unterliegt denselben Bedingungen, die auch für die standardmäßige beschränkte Einjahresgarantie von Greenlee Tools, Inc. gelten. Bei allen Reparaturen von Messgeräten muss eine Rücksendegenehmigung bei der Kundendienstabteilung unter +1-800-435-0786 angefordert werden. Bei Geräten ohne Garantieschutz (z.B. heruntergefallene oder missbrauchte Produkte) kann auf Anfrage ein Kostenvoranschlag für die Reparatur erstellt werden. Hinweis: Bitte prüfen Sie vor dem Einsenden des Geräts die austauschbaren Batterien bzw. stellen Sie sicher, dass die Batterie vollständig geladen ist. 83 Register this product at www.greenlee.com Registre este producto en www.greenlee.com Enregistrez votre produit en ligne, www.greenlee.com Dieses Produkt kann unter www.greenlee.com registriert werden 4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070 An ISO 9001 Company • ©2019 Greenlee Tools, Inc. USA Tel: 800-435-0786 Fax: 800-451-2632 Canada Tel: 800-435-0786 Fax: 800-524-2853 www.greenlee.com International Tel: +1-815-397-7070 Fax: +1-815-397-9247
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Greenlee CM-660, CM-860, CM-960, CMI-600, CMH-600 Clamp Meter Manual Manual de usuario

Categoría
Medición
Tipo
Manual de usuario
Este manual también es adecuado para