SCHEDULE
US Certificate Of Conformity No: FM17US0275X
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +
1 (1) 781 762 4300 F: +
1 (1) 781 762 9375 E-mail: informat[email protected]om www.fmapprovals.com
F 347 (Mar 16) Page 2 of 4
Intrinsically safe for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G hazardous (classified)
locations; Intrinsically safe for Class I, Zone 0, Group IIC hazardous (classified) locations; Intrinsically safe
for Zone 20, Group IIIC hazardous (classified) locations; nonincendive for Class I, Division 2, Groups A, B,
C, and D, hazardous (classified) locations; Suitable for Class II and III, Division 2 hazardous (classified)
locations. Temperature classification T4. Ambient temperature range -20°C to +60°C for PR 6130/6ab and
PR 6021/68S,-30°C to +60°C for PR6130/64Sa-Temp, PR6130/64C-Temp and PR6130/65S-Temp and -
40°C to 60°C for PR6130/68S-Temp and PR6021/68S-Temp. Indoor and outdoor Type 4X and IP6x.
The marking of the equipment shall include:
PR 6130/6[a][b] and PR 6021/68S Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-751-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-751-07; 4X, IP6x
CL I, Zone 0, AEx ia IIC T4 - 36931-751-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-751-07; 4X, IP6x
T4 Ta= -20°C to 60°C
PR 6130/64Sa-Temp, PR 6130/64C-Temp and PR 6130/65S-Temp Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-731-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-751-07; 4X, IP6x
CL I, Zone 0, AEx ia IIC T4 - 36931-731-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-731-07; 4X, IP6x
T4 Ta= -30°C to 60°C
PR 6130/68S-Temp and PR 6021/68S-Temp Cable Junction Box
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G T4 - 36931-721-07; 4X, IP6x
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G T4; 4X, IP6x
S CL II, DIV 2, GP E,F,G / T4; 4X, IP6X,
S CL III, DIV 1 T4 - 36931-721-07; 4X, IP6x
CL I, Zone 0, Ex ia IIC T4 - 36931-721-07; 4X, IP6x
Zone 20, AEx ia IIIC T90°C - 36931-721-07; 4X, IP6x
T4 Ta= -40°C to 60°C
Description of Equipment:
General - The Cable Junction Boxes are designed to interconnect up to 8 load cells and then connect this
arrangement to the interface of an evaluation unit (e.g. indicator).
Construction - The Cable Junction Boxes series PR 6130/6… and PR 6021/6… consist of stainless steel
housings with ingress protection IP6x in accordance with ANSI/IEC 60529 and Type 4X. All screws, flat and lock
washers are also made of stainless steel.