Cooper Lumark Prevail Installation Instructions Manual

Tipo
Installation Instructions Manual

Este manual también es adecuado para

INS #
Brand Logo
reversed out of
black
INS #
IB50 00 02EN
Installation Instructions – Prevail / USSL
Instructions d’installation – Prevail / USSL
Instrucciones de instalacn – Prevail / USSL
WARNINGWARNING
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind
that may arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Green ground wire provided in proper location. Do not relocate.
ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be
filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
Safety: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area
of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to
installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation
and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and
maintained according to the following recommendations.
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this
product must be performed by a qualified electrician. This product must be installed in accordance
with the applicable installation code by a person familiar with the construction and operation of the
product and hazards involved.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting
any maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Refer to product label for specific minimum supply conductor requirements.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
Regulatory Information: This equipment has been test and found to comply with the limits of a Class A digital
device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
2
Cooper Lighting Solutions IB500002EN Installation instructions
Installation Instructions – Prevail / USSL
INSTALLATION
This lighting fixture has been shipped complete with one
of several mounting options. Please follow the installation
instructions specific to the catalog part that you ordered.
ote: N Care must be taken not to set lighting fixture down
on optical lenses or lift the fixture by the lens.
Tools Required
Ratchet, 3/4” socket, 3/4” wrench, #2 Phillips head screw
driver and torque wrench.
Pole Mount Arm (Figure 1. - Figure 5.)
1. Pole mounting arm is designed for a square or round
pole. Round pole installation will require the mounting
arm break away tabs to be removed. Grab break away
tab with pliers and break-away the tab. (Figure 1.)
2. Mount the arm to the round or square pole using the
provided 1/2” x 1-3/4” long bolts and nuts as shown.
Torque bolts to 40 foot-lbs. (55 N-M). (Figure 2.)
3. Fold fixtures wires tightly towards fixture door when
sliding fixture on to mounting arm. Tighten the center
phillips head screw to 20 in-lbs. (2.3 N-M). (Figure 3.)
4. Make wire connections inside the mounting arm. Refer
to wire diagram for power connections. Connect the
supply wires to appropriate luminaire leads: (Figure 4.)
Supply side ground wire to green luminaire lead.
Supply side neutral wire to white luminaire lead.
Supply side line voltage wire to black luminaire lead.
5. Install arm cover and tighten phillips head screws to 20
in-lbs. (2.3 N-M).
ote: N Ensure the luminaire supply leads do not get pinched
between cover and mounting arm. (Figure 5.)
6. Install pole cap after completion of luminaire installation
and wiring.
Figure 2.
Figure 3.
Line (Black)
Black
White
(Black
480V)
Green
Ground
Fixture
White Common
(Black 480V)
Green Ground
Cover Plate Screws.
Tighten to 20 in-lbs
(2.3N-M)
Align Cover Tabs
With Arm Slots
Washer
1/2” Bolt
1/2” Nut
Washer
Split Washer
Close-Up View
Center Phillips Head Screw And
Tighten to 20 in-lbs. (2.3N-M)
Figure 1.
For Round Pole
Installations,
Break away Tabs
9/16” (14.3mm)
Diameter Hole and
Slot
4-7/8”
(124mm)
7/8”
(22mm)
Figure 4.
Figure 5.
3
Cooper Lighting Solutions IB500002EN Installation instructions
Installation Instructions – Prevail / USSL
Tools required
#2 Phillips head screw driver, torque wrench.
ote: N Hardware and tools to mount wall plate to wall not
supplied.
Wall Mount (Figure 6.)
1. Pull the supply wires out of junction box (not supplied)
and through the large hole in the center of the wall
plate.
2. Secure attachment plate to the wall using four bolts
(not included).
3. Follow instructions step 3 through 5 from pole mount
arm configuration.
Tools required
1/4” Allen wrench, #2 Phillips head screw driver, torque
wrench, drill and 7/16” drill bit.
Mast Arm Mount (Figure 7. and Figure 8.)
1. Slip the mast arm mounting assembly over the mast
arm (making sure not to pinch any supply leads). Make
sure the mast arm is fully seated into the mast arm
adapter as it should bottom out against the adapter.
2. Secure the mast arm adapter to the mast arm with
the (4) 3/8-16 x 3/8” set screws. Level the mast arm
adapter while tightening the set screws. Torque to 120
in-lbs.
3. Drill a 7/16” hole through the mast arm and install the
3/8” bolt and nut. Use care when drilling this hole so as
not to damage any wires within the mast arm. Torque
to 120 in-lbs.
4. Open fixture door by loosening the (4) Phillips head
screws (or thumb screws if supplied) on the door.
(Figure 8.)
5. Remove wire grommet for fixture wires at the back of
the fixture. (Figure 8.)
6. Fold fixtures wires and mast arm adapter wires out of
the way and slide fixture on to the mast arm adapter.
Tighten the three phillips head screws to 20 in-lbs. (2.3
N-M), and install the plastic plug over the center screw.
(Figure 7.)
7. Make wire connections inside the fixture. Refer to wire
diagram for power connections. Connect the supply
wires to appropriate luminaire leads: (Figure 4.)
Supply side ground wire to green luminaire lead.
Supply side neutral wire to white luminaire lead.
Supply side line voltage wire to black luminaire lead.
8. Tuck wires into the fixture and install fixture door.
Tighten the (4) fixture door screws to 20 in-lbs. (or
tighten door thumb screws).
Wall Plate
Wireway
(Center Hole)
6x8 Plate Size
Mast Arm Pole
(2” Tenon Arm)
Level Surface
3/8” Bolt
Wire
Grommet
Open Fixture
Door
Set Screws (Torque to
120 in-lbs.)
Tighten to 20 in-lbs.
7.12
[180.85]
.44 dia
[11.20]
5.12
[130.05]
6.00
[152.40]
8.00
[203.20]
Figure 6.
Figure 7.
Figure 8.
4
Cooper Lighting Solutions IB500002EN Installation instructions
Installation Instructions – Prevail / USSL
Tools required
#2 Phillips head screw driver and pliers.
House Side Shield (Figure 9. and Figure 10.)
1. Remove plastic push pins on back side of optic.
(Figure 9.)
ote: N The optics are permanently secured to the fixture. DO NOT
try to remove the optics. The optics are not rotatable.
2. Install house side shield with provided #10 x 1/2” Phillips
screws. Tighten until house side shield is snug. Do not over
tighten.
ote: N House side shield must ONLY be installed on the back side
of the optics as shown. DO NOT install on the other side of
the optic. (Figure 10.)
House Side Shield for rectangle shaped optics (Figure 11.)
1. Remove the six torx type screws around the optics.
ote: N The optics are permanently secured to the fixture. DO NOT
try to remove the optics. The optics are not rotatable.
2. Place House Side shield over the optics. All six screw holes
will align with the optic if the House Side Shield is installed
correctly.
ote: N The light will shine out of the rounded portion of the lens.
The sharp vertical portion of the lens is the house side of
the lens.
3. Re-install all six torx screws per the rectangle optic(s) on your
fixture. Torque to 10 to 15 in-lbs.
Photocontrol Orientation (If Equipped) (Figure 12.)
ote: N The orientation procedure is only required for photocontrols
which specifically require the cell to be aimed north.
Otherwise pre-selected factory orientation will function
properly. Follow the directions recommended by the
photocontrol supplier for proximity to light sources. Lighted
signs, building surface reflection, floodlights, tree branches,
etc. may affect final position of the photocontrol.
1. Loosen the two screws to allow rotation of the receptacle.
2. Insert screwdriver into center slot and rotate receptacle until
indicator arrow points north.
3. Retighten screws.
4. Insert the photoelectric control (or shorting cap) into
receptacle and twist into locked position.
ote: N The photocontrol (not included) must contain a soft,
resilient gasket fastened to the bottom surface to assure
a proper weather seal between the control and the
receptacle.
ote: N Always use a photocontrol rated for 120V to 277V.
Fixtures ordered with 347V or 480V power connection will
use a 120V to 277V photocontrol. Fixture is wired with
photocontrol after transformer (347V and 480V only).
Front of
Fixture
Pole
Side of
Fixture
Optic
Plastic
Pins
Figure 9.
Figure 11.
(6) Torx type
screws
House Side
Shield
Loosen
Screws
Insert Flat Head
and Rotate
Figure 12.
Front of
Fixture
Pole
Side of
Fixture
Screws
#10 x 1/2”
House Side Shield
Figure 10.
5
Cooper Lighting Solutions IB500002EN Instructions d’installation
Instructions d’installation – Prevail / USSL
AVERTISSEMENTAVERTISSEMENT
EXONÉRATION DE RESPONSABILITÉ: Cooper Lighting Solutions n’assume aucune responsabilité pour les
dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou
d’une utilisation inappropriée, imprudente ou négligente de ce produit.
AVIS: Le fil de mise à la terre vert se trouve au bon endroit. Ne le déplacez pas.
ATTENTION Service de réception: Veuillez fournir une description réelle de tout manque ou de tout dommage
constaté à la réception du luminaire. Les réclamations contre le transporteur (chargement partiel) doivent être
déposées directement auprès dudit transporteur. Les réclamations d’avaries occultes doivent être faites dans les
15jours suivant la réception. Tout matériel endommagé doit être entièrement conservé avec son emballage d’origine.
Sécurité: Le câblage du luminaire doit être conforme au Code national de l’électricité, aux lois et ordonnances
locales en vigueur. Une mise à la terre adéquate est requise afin d’assurer votre sécurité. Respectez soigneusement
la procédure de mise à la terre du chapitre d’installation.
APPLICATIONS: ce luminaire a été conçu pour l’éclairage extérieur et ne doit pas être utilisé dans un endroit peu
ventilé ou dans des enceintes à haute température ambiante. Il doit être rangé dans un endroit sec en attendant
son installation. N’exposez pas le luminaire à la pluie, à la poussière ou à d’autres conditions ambiantes avant
l’installation et l’insertion de l’interrupteur photo-électrique ou de la fiche de mise en court-circuit (si équipés). Pour
de meilleurs résultats, respectez les recommandations d’installation et d’entretien suivantes.
Risque d’incendie, de décharge électrique, de coupure ou d’autres accidents de personne – L’installation
et l’entretien de ce produit doivent être effectués par un électricien qualifié. Ce produit doit être installé
conformément aux règles d’installation en vigueur par une personne familière avec la construction et le
fonctionnement du produit, ainsi qu’avec les risques inhérents.
Risque d’incendie et de décharge électrique – Assurez-vous que l’alimentation électrique est HORS
TENSION avant de commencer l’installation ou de tenter d’en faire l’entretien. Mettez l’alimentation
électrique hors tension depuis le fusible ou le disjoncteur.
Risque d’incendie – Consultez l’étiquette du produit pour connaître les exigences minimums du
conducteur d’alimentation.
Risque de brûlure– Débranchez la source d’alimentation et laissez refroidir le luminaire avant de procéder
à son entretien ou à sa manipulation.
Risques de blessures – Le luminaire peut être endommagé et/ou instable s’il n’est pas installé
correctement.
La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et de
dommages matériels.
Renseignements légaux: Cet équipement a été mis à l’essai et déclaré conforme aux limites établies pour un
dispositif numérique de catégorieA en vertu de la section15 des règlements de la FCC. Son fonctionnement est
assujetti aux deux conditions suivantes: 1)cet appareil ne doit pas provoquer d’interférences nuisibles et 2)cet
appareil doit accepter toutes les interférences reçues, même celles qui pourraient provoquer un fonctionnement
indésirable.
6
Cooper Lighting Solutions IB500002EN Instructions d’installation
Instructions d’installation – Prevail / USSL
INSTALACIÓN
Esta luminaria se ha enviado completa con una de las varias
opciones de montaje. Siga las instrucciones de instalación
específicas para la pieza que haya solicitado del catálogo.
ota: N Se deben tomar precauciones para no bajar la
luminaria sobre las lentes ópticas ni levantarla en el
área de la lente.
Herramientas necesarias
Trinquete, portacasquillos de 3/4 pulgadas, llave de 3/4
pulgadas, destornillador cabeza Phillips n.° 2 y llave de
torsión.
Brazo para montaje en poste (Figura 1. - Figura 5.)
1. El brazo para montaje en postes está diseñado para
un poste cuadrado o redondo. Para instalar la luminaria
en un poste redondo se deberán retirar las lengüetas
troqueladas del brazo de montaje. Sujete la lengüeta
troquelada con unas pinzas y despréndala. (Figura 1.)
2. Monte el brazo sobre el poste redondo o cuadrado
con los pernos de 1/2” x 1-3/4” y las tuercas incluidos
como se indica. Ajuste los pernos con un torque de 40
pies-lb. (55 Nm). (Figura 2.)
3. Doble los cables de la luminaria hacia la puerta de la
luminaria cuando deslice la luminaria hacia el brazo de
montaje. Ajuste el tornillo Phillips central hasta
20 lb-pulg. (2,3 Nm). (Figura 3.)
4. Conecte los cables en el interior del brazo de montaje.
Consulte el diagrama de cableado para conocer las
conexiones de la alimentación. Conecte los cables
de alimentación a los conectores adecuados de la
luminaria: (Figura 4.)
Cable de conexión a tierra del lado de la alimentación
con el terminal verde de la luminaria.
Cable neutro del lado de la alimentación con el
terminal blanco de la luminaria.
Cable de tensión de línea del lado de la alimentación
con el terminal negro de la luminaria.
Figura 1.
Figura 3.
Figura 4.
Figura 5.
Línea (Negro)
Negro
Blanco
(Negro
480 V)
Verde
Tierra
Luminaria
Blanco Común
(Negro 480 V)
Verde Tierra
Para instalaciones
en postes
redondos,
desprenda las
lengüetas
9/16” (14,3 mm)
Ranura y orificio de
4-7/8”
(124 mm)
7/8” (22
mm) de
diámetro
Tornillos de la placa de
la cubierta Ajuste hasta
20 pulg.-lb (2,3 N-M)
Alinee las lengüetas de la cubierta
con las ranuras de los brazos
Vista de cerca
Tornillo Phillips central y ajústelo
hasta 20 pulg.-lb (2.3 N-M)
Rondelle
Boulon de
1,27cm
(1/2po)
Écrou de
1,27cm (1/2po)
Rondelle
Rondelle fendue
Figura 2.
Rondelle
Boulon de
1,27cm
(1/2po)
Écrou de
1,27cm (1/2po)
Rondelle
Rondelle fendue
7
Cooper Lighting Solutions IB500002EN Instructions d’installation
Instructions d’installation – Prevail / USSL
5. Instale la cubierta del brazo y ajuste los tornillos Philips
con un torque de 20 pulg.-lb. (2,3 Nm).
ota: N Asegúrese de que los terminales del lado de la
alimentación de la luminaria no queden “mordidos”
ente la cubierta y el brazo de montaje. (Figura 5.)
6. Coloque la tapa superior del poste luego de finalizar la
instalación y el cableado de la luminaria.
Herramientas necesarias
Tornillo cabeza Phillips n.° 2, llave de torsión.
ota: N Los accesorios y las herramientas para colocar la
placa de pared en la pared no están incluidos.
Montaje en pared (Figura 6.)
1. Tire de los cables de alimentación hacia afuera de la
caja de derivación (no incluida) y a través del orificio
amplio en el centro de la placa de pared.
2. Asegure la placa de sujeción a la pared utilizando cuatro
pernos (no incluidos)
3. Siga las instrucciones del paso 3 al 5 de la
configuración del brazo para montaje en poste.
Herramientas necesarias
Llave allen de 1/4", destornillador Phillips n.° 2, llave de
torsión, taladro y broca para taladro de 7/16".
Montaje en brazo del mástil (Figura 7. y Figura 8.)
1. Deslice la unidad de montaje para el brazo del mástil
sobre este último (asegurándose de no apretar
ninguno de los cables de alimentación). Asegúrese de
que el brazo del mástil esté totalmente apoyado en
el adaptador para el brazo del mástil, ya que debería
quedar contra el adaptador.
2. Asegure el adaptador del brazo mástil al brazo con
los (4) tornillos de sujeción de 3/8-16 x 3/8". Nivele
el adaptador del brazo del mástil mientras ajusta los
tornillos de sujeción. Ejerza torsión a 120 pulg./lb.
3. Perfore un orificio de 7/16" a través del brazo mástil
y coloque el perno de 3/8" y la tuerca. Tenga cuidado
cuando realice la perforación para no dañar ningún
cable dentro del brazo mástil. Ejerza torsión a
120 pulg./lb.
4. Abra la puerta de la luminaria aflojando los (4) tornillos
Phillips (o las tuercas mariposa si estuvieran incluidas)
de la puerta. (Figura 8.)
5. Quite la arandela aislante en la parte trasera para los
cables de la luminaria. (Figura 8.)
6. Pliegue los cables de las luminarias y los cables del
adaptador para brazo mástil para sacarlos del camino
y deslice la luminaria sobre el adaptador para el brazo
mástil. Ajuste los tres tornillos Phillips hasta 20 pulg.
libras (2.3 N-M) e instale el tapón de plástico sobre el
tornillo central. (Figura 7.)
Figura 6.
Figura 7.
Figura 8.
Placa para pared
Conducto de cables
(orificio central)
Tamaño de la placa 6 x 8
Poste del brazo mástil
(Brazo espiga de 2")
Superficie a
nivel
Perno de 3/8”
Arandela
aislante
para cables
Abra la puerta
de la luminaria
Tornillos de sujeción
(Ajuste hasta 120 pulg.-lb)
Ajuste hasta 20 pulg.-lb (2,3 N-M).
7,12
[180,85]
0,44 de
diámetro [11,20]
5,12
[130,05]
6,00
[152,40]
8,00
[203,20]
7. Conecte los cables en el interior de la luminaria.
Consulte el diagrama de cableado para conocer las
conexiones de la alimentación. Conecte los cables
de alimentación a los conectores adecuados de la
luminaria: (Figura 4.)
8
Cooper Lighting Solutions IB500002EN Instructions d’installation
Instructions d’installation – Prevail / USSL
Outillage nécessaire
Tournevis cruciforme n°2 et pince.
Protecteur côté maison (Figure 9. et Figure 10.)
1. Retirez les barrettes à ressort en plastique qui se trouvent derrière
le dispositif optique. (Figure9.)
emarque: R Les dispositifs optiques sont fixés de manière
permanente au luminaire. N'essayez PAS de les retirer. Les
dispositifs optiques ne sont pas remplaçables.
2. Installez les protecteurs côté maison avec les vis à tête
hexagonale #10 x 12,7 mm (1/2 po) fournies. Serrez jusqu'à ce que
le protecteur côté maison soit bien fixé. Ne serrez pas trop.
emarque: R Le protecteur côté maison doit UNIQUEMENT être installé
à l'arrière du dispositif optique, tel qu'illustré. NE l'installez
PAS sur l'autre côté du dispositif optique. (Figure10.)
Protecteur côté maison pour les dispositifs optiques
rectangulaires (Figure 11)
1. Retirez les six vis de type Torx autour des dispositifs optiques
emarque: R Les dispositifs optiques sont fixés de manière
permanente au luminaire. N’essayez PAS de les retirer.
Les dispositifs optiques ne peuvent pas être tournés.
2. Placez le protecteur côté maison sur les dispositifs optiques.
Les six trous de vis s’aligneront avec le dispositif optique si le
protecteur côté maison est correctement installé.
emarque: R La lumière sortira de la partie arrondie de l’objectif.
La partie verticale tranchante de la lentille correspond au côté
maison de la lentille.
3. Réinstallez les six vis de type Torx par dispositif optique
rectangulaire sur votre luminaire. Serrez à un couple de 10 à 15 lb/
po.
Orientation de la cellule photoélectrique (si le
luminaire en est doté) (Figure 12)
emarque: R Cette procédure ne vise que les cellules photoélectriques
qui doivent absolument être orientées vers le nord. Dans
les autres cas, les réglages définis en usine les rendront
parfaitement fonctionnels. Respectez les instructions du
fournisseur de la cellule photoélectrique lorsqu'elle se
trouve à proximité de sources d'éclairage. La présence de
panneaux lumineux, de projecteurs et de branches d'arbres,
la réflexion lumineuse sur les surfaces d'immeubles,
etc., peuvent influencer la position finale de la cellule
photoélectrique.
1. Desserrez les deux vis pour permettre la rotation de la prise.
2. Insérez un tournevis dans la fente centrale pour faire tourner le
connecteur jusqu'à ce que la flèche pointe vers le nord.
Desserrez les vis
Insérez la vis à tête plate puis
tournez
Le fil de mise en terre provenant de l’alimentation avec
le fil vert du luminaire.
Le fil neutre provenant de l’alimentation avec le fil blanc
du luminaire.
Le fil de tension provenant de l’alimentation avec le fil
noir du luminaire.
5. Introduisez les fils dans le luminaire et installez la porte
du luminaire. Serrez les (4) vis de la porte du luminaire
à 2,3 Nm (20 po-lb) (ou serrez les vis à ailettes).
3. Resserrez les vis.
4. Insérez l'interrupteur photoélectrique (ou fiche de mise
en court-circuit) dans le réceptacle et tournez-le pour le
verrouiller en place.
emarque: R La cellule photoélectrique (non fournie) doit être
équipée d'un joint souple élastique situé sur la
surface inférieure afin d'assurer l'étanchéité
avec le connecteur.
emarque: R Utilisez toujours une cellule photoélectrique d'une
capacité de 120 V à 277 V. Les luminaires commandés
avec une connexion électrique de 347 V ou de 480
V nécessiteront une cellule photoélectrique de 120
V à 277 V. Le luminaire est câblé avec une cellule
photoélectrique après le transformateur (347 V et 480
V seulement).
Figura 9.
Devant
du
luminaire
Côté poteau du luminaire
Dispositif
optique
Barrettes en
plastique
Figura 11.
Vis de
type Torx
Protecteur
côté maison
Figura 12.
Devant
du
luminaire
Côté poteau
du luminaire
Vis n° 10 x 12,7 mm
(1/2 po)
Protecteur côté
maison
Figura 10.
Instrucciones de instalación – Prevail / USSL
9
Cooper Lighting Solutions IB500002EN Instructions d’installation
ADVERTENCIAADVERTENCIA
RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o
pérdidas de ningún tipo que puedan derivarse de la instalación, manipulación o uso incorrecto, descuidado o
negligente de este producto.
AVISO: El tornillo de puesta a tierra verde ya está ubicado correctamente. No lo cambie de ubicación.
ATENCIÓN Departamento de Recepción: Observe que la descripción real de la luminaria no carezca de piezas ni
presente daños notorios al momento de su entrega. Presente el reclamo directamente al transportista de carga por
envíos de carga ligera (LTL). Los reclamos por daños ocultos deben presentarse dentro de los 15 días posteriores a la
entrega del producto. Se debe guardar todo el material dañado, junto con el embalaje original.
Seguridad: Esta luminaria debe cablearse de acuerdo con el Código Eléctrico Nacional y los códigos y ordenanzas
locales aplicables. Se requiere una conexión a tierra adecuada para garantizar la seguridad personal. Observe
cuidadosamente el procedimiento de conexión a tierra en la sección de instalación.
APLICACIONES: Este accesorio de iluminación está diseñado para servicios de iluminación al aire libre y no debe
utilizarse en áreas de ventilación limitada o en lugares cerrados a alta temperatura ambiente. Debe almacenarse en
un lugar seco antes de la instalación. No exponga el accesorio de iluminación a la lluvia, el polvo u otras condiciones
ambientales antes de la instalación e inserción del control fotográfico o la tapa de cortocircuito (si está equipado).
Los mejores resultados se obtendrán si se instala y se mantiene de acuerdo con las siguientes recomendaciones.
Riesgo de incendio, descarga eléctrica, cortes u otros riesgos de accidentes: la instalación y el
mantenimiento de este producto deben ser realizados por un electricista calificado. Una persona con
conocimientos sobre la construcción y el funcionamiento del producto y los riesgos implicados debe
instalar este producto de conformidad con el código de instalación aplicable.
Riesgo de incendio y descarga eléctrica: asegúrese de que la alimentación eléctrica esté APAGADA
antes de comenzar la instalación o intentar realizar cualquier tipo de mantenimiento. Desconecte la
alimentación eléctrica en el fusible o cortacircuitos.
Riesgo de incendio: consulte la etiqueta del producto para conocer los requisitos mínimos específicos del
conductor de suministro.
Riesgo de quemadura: desconecte la alimentación y permita que la luminaria se refresque antes de
manipularla o repararla.
Riesgo de lesiones personales: la luminaria puede dañarse o desestabilizarse de no instalarla
correctamente.
El incumplimiento de estas instrucciones puede provocar la muerte, lesiones corporales graves y daños
materiales.
Información reglamentaria: Este equipo ha sido probado y cumple con los límites de un dispositivo digital de
Clase A, de conformidad con la parte 15 de las Normas de la FCC. La operación está sujeta a las siguientes dos
condiciones: (1) Que este dispositivo no produzca interferencia dañina y (2) que este dispositivo debe aceptar
cualquier interferencia recibida, incluida aquella que pueda provocar un funcionamiento no deseado.
Instrucciones de instalación – Prevail / USSL
10
Cooper Lighting Solutions IB500002EN Instructions d’installation
INSTALACIÓN
Esta luminaria se ha enviado completa con una de las varias
opciones de montaje. Siga las instrucciones de instalación
específicas para la pieza que haya solicitado del catálogo.
ota: N Se deben tomar precauciones para no bajar la
luminaria sobre las lentes ópticas ni levantarla en el
área de la lente.
Herramientas necesarias
Trinquete, portacasquillos de 3/4 pulgadas, llave de 3/4
pulgadas, destornillador cabeza Phillips n.° 2 y llave de
torsión.
Brazo para montaje en poste (Figura 1. - Figura 5.)
1. El brazo para montaje en postes está diseñado para
un poste cuadrado o redondo. Para instalar la luminaria
en un poste redondo se deberán retirar las lengüetas
troqueladas del brazo de montaje. Sujete la lengüeta
troquelada con unas pinzas y despréndala. (Figura 1.)
2. Monte el brazo sobre el poste redondo o cuadrado
con los pernos de 1/2” x 1-3/4” y las tuercas incluidos
como se indica. Ajuste los pernos con un torque de 40
pies-lb. (55 Nm). (Figura 2.)
3. Doble los cables de la luminaria hacia la puerta de la
luminaria cuando deslice la luminaria hacia el brazo de
montaje. Ajuste el tornillo Phillips central hasta
20 lb-pulg. (2,3 Nm). (Figura 3.)
4. Conecte los cables en el interior del brazo de montaje.
Consulte el diagrama de cableado para conocer las
conexiones de la alimentación. Conecte los cables
de alimentación a los conectores adecuados de la
luminaria: (Figura 4.)
Cable de conexión a tierra del lado de la aliment
ación con el terminal verde de la luminaria.
Cable neutro del lado de la alimentación con el
terminal blanco de la luminaria.
Cable de tensión de línea del lado de la alimentación
con el terminal negro de la luminaria.
Figura 1.
Figura 2.
Figura 3.
Figura 4.
Figura 5.
Línea (Negro)
Negro
Blanco
(Negro
480 V)
Verde
Tierra
Luminaria
Blanco Común
(Negro 480 V)
Verde Tierra
Para instalaciones
en postes
redondos,
desprenda las
lengüetas
9/16” (14,3 mm)
Ranura y orificio de
4-7/8”
(124 mm)
7/8” (22
mm) de
diámetro
Tornillos de la placa de
la cubierta Ajuste hasta
20 pulg.-lb (2,3 N-M)
Alinee las lengüetas de la cubierta
con las ranuras de los brazos
Arandela
Perno de 1/2”
Tuerca de 1/2”
Arandela
Arandela ranurada
Vista de cerca
Tornillo Phillips central y ajústelo
hasta 20 pulg.-lb (2.3 N-M)
Instrucciones de instalación – Prevail / USSL
11
Cooper Lighting Solutions IB500002EN Instructions d’installation
5. Instale la cubierta del brazo y ajuste los tornillos Philips
con un torque de 20 pulg.-lb. (2,3 Nm).
ota: N Asegúrese de que los terminales del lado de la
alimentación de la luminaria no queden “mordidos”
ente la cubierta y el brazo de montaje. (Figura 5.)
6. Coloque la tapa superior del poste luego de finalizar la
instalación y el cableado de la luminaria.
Herramientas necesarias
Tornillo cabeza Phillips n.° 2, llave de torsión.
ota: N Los accesorios y las herramientas para colocar la
placa de pared en la pared no están incluidos.
Montaje en pared (Figura 6.)
1. Tire de los cables de alimentación hacia afuera de la
caja de derivación (no incluida) y a través del orificio
amplio en el centro de la placa de pared.
2. Asegure la placa de sujeción a la pared utilizando cuatro
pernos (no incluidos)
3. Siga las instrucciones del paso 3 al 5 de la
configuración del brazo para montaje en poste.
Herramientas necesarias
Llave allen de 1/4", destornillador Phillips n.° 2, llave de
torsión, taladro y broca para taladro de 7/16".
Montaje en brazo del mástil (Figura 7. y Figura 8.)
1. Deslice la unidad de montaje para el brazo del mástil
sobre este último (asegurándose de no apretar
ninguno de los cables de alimentación). Asegúrese de
que el brazo del mástil esté totalmente apoyado en
el adaptador para el brazo del mástil, ya que debería
quedar contra el adaptador.
2. Asegure el adaptador del brazo mástil al brazo con
los (4) tornillos de sujeción de 3/8-16 x 3/8". Nivele
el adaptador del brazo del mástil mientras ajusta los
tornillos de sujeción. Ejerza torsión a 120 pulg./lb.
3. Perfore un orificio de 7/16" a través del brazo mástil
y coloque el perno de 3/8" y la tuerca. Tenga cuidado
cuando realice la perforación para no dañar ningún
cable dentro del brazo mástil. Ejerza torsión a
120 pulg./lb.
4. Abra la puerta de la luminaria aflojando los (4) tornillos
Phillips (o las tuercas mariposa si estuvieran incluidas)
de la puerta. (Figura 8.)
5. Quite la arandela aislante en la parte trasera para los
cables de la luminaria. (Figura 8.)
6. Pliegue los cables de las luminarias y los cables del
adaptador para brazo mástil para sacarlos del camino
y deslice la luminaria sobre el adaptador para el brazo
mástil. Ajuste los tres tornillos Phillips hasta 20 pulg.
libras (2.3 N-M) e instale el tapón de plástico sobre el
tornillo central. (Figura 7.)
Figura 6.
Figura 7.
Figura 8.
Placa para pared
Conducto de cables
(orificio central)
Tamaño de la placa 6 x 8
Poste del brazo mástil
(Brazo espiga de 2")
Superficie a
nivel
Perno de 3/8”
Arandela
aislante
para cables
Abra la puerta
de la luminaria
Tornillos de sujeción
(Ajuste hasta 120 pulg.-lb)
Ajuste hasta 20 pulg.-lb (2,3 N-M).
7,12
[180,85]
0,44 de
diámetro [11,20]
5,12
[130,05]
6,00
[152,40]
8,00
[203,20]
7. Conecte los cables en el interior de la luminaria.
Consulte el diagrama de cableado para conocer las
conexiones de la alimentación. Conecte los cables
de alimentación a los conectores adecuados de la
luminaria: (Figura 4.)
Instrucciones de instalación – Prevail / USSL
12
Cooper Lighting Solutions IB500002EN Instructions d’installation
Herramientas necesarias
Tornillo cabeza Phillips n.° 2 y pinzas.
Pantalla lateral del alojamiento (Figura 9. y Figura 10.)
1. Quite las tachuelas de plástico en el lado de la óptica.
(Figura 9.)
ota: N Las ópticas se fijan permanentemente a la luminaria.
NO intente quitar las ópticas. Las ópticas no se
pueden girar.
2. Instale la pantalla lateral del alojamiento con los tornillos
Phillips n.° 10 x 1/2". Ajuste hasta que la pantalla lateral
del alojamiento esté apretada. No la sobreajuste.
ota: N La pantalla lateral del alojamiento SOLO se debe
instalar en el lado trasero de la óptica, como se
muestra. NO instalar en el otro lado de la óptica.
(Figura 10.)
Pantalla lateral del alojamiento para las ópticas en
forma de rectángulo (Figura 11).
1. Retire los seis tornillos tipo Torx que se encuentran
alrededor de las ópticas.
emarque: R Las ópticas están fijas de manera permanente
a la luminaria. NO intente quitar las ópticas. Las ópti-
cas no son giratorias.
2. Coloque la pantalla lateral del alojamiento sobre las
ópticas. Los seis orificios para tornillos se alinearán con
la óptica si la pantalla lateral del alojamiento se instala
correctamente
emarque: R La luz brillará desde la parte redondeada de la
lente. La porción vertical afilada de la lente es el lado
de la lente orientado hacia el alojamiento.
3. Vuelva a instalar los seis tornillos Torx según la(s)
óptica(s) rectangular(es) en su luminaria. Apriete con
una fuerza de 10 a 15 pulg./lb (1,13 a 1,69 N·m).
Orientación del fotocontrol (si estuviera incluido)
(Figura 12.)
ota: N El procedimiento de orientación solo es
necesario para los fotocontroles que requieren,
específicamente, que la celda apunte hacia el
norte. De lo contrario, la orientación seleccionada
previamente en fábrica funcionará adecuadamente.
Cable de conexión a tierra del lado de la aliment
ación con el terminal verde de la luminaria.
Cable neutro del lado de la alimentación con el
terminal blanco de la luminaria.
Cable de tensión de línea del lado de la aliment
ación con el terminal negro de la luminaria.
5. Introduzca los cables en la luminaria y coloque la
puerta. Ajuste los (4) tornillos de la puerta de la
luminaria hasta 20 pulg.-lb (o ajuste los tornillos
mariposa de la puerta).
Figura 9.
Frente
de la
luminaria
Lado del
poste de la
luminaria
Óptica
Tachuelas
de
plástico
Figura 10.
Frente
de la
luminaria
Lado del
poste
de la
luminaria
Tornillos
n.° 10 x
1/2"
Pantalla de cuatro lados
13
Introduzca el destornillador de
cabeza plana y hágalo girar
Figura 12.
Afloje los
tornillos
Siga las instrucciones recomendadas por el
proveedor del fotocontrol respecto de su proximidad
a las fuentes de iluminación. La posición final del
fotocontrol puede verse afectada por señalizaciones
iluminadas, reflexiones en las superficies del edificio,
reflectores, ramas de árboles, etc.
1. Afloje los dos tornillos para poder girar el receptáculo.
2. Inserte el destornillador en la ranura central y gire el
receptáculo hasta que la flecha de indicación apunte
hacia el norte.
3. Vuelva a ajustar los tornillos.
4. Inserte el control fotoeléctrico (o el tapón de
cortocircuito) en el receptáculo y gírelo a la posición de
bloqueo.
ota: N El fotocontrol (no incluido) debe contener una junta
suave y elástica ajustada a la parte inferior de su
superficie para garantizar un apropiado sellado
hermético entre el control y el receptáculo.
ota: N Siempre utilice un fotocontrol apto para 120 V a
277 V. Las luminarias que solicite con conexión de
alimentación de 347 V o 480 V usarán un fotocontrol
de 120 V a 277 V. La luminaria se conecta al
fotocontrol después del transformador (347 V y 480 V
solamente).
Figure 11.
Tornillos
tipo Torx
Pantalla
lateral del
alojamiento
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2020 Cooper Lighting Solutions
All Rights Reserved
Publication No. IB500002EN
March 19, 2020
Cooper Lighting Solutions is a
registered trademark.
All trademarks are property
of their respective owners.
Cooper Lighting Solutions est une
marque de commerce déposée.
Toutes les autres marques de
commerce sont la propriété de leur
propriétaire respectif.
Cooper Lighting Solutions es una
marca comercial registrada. Todas las
marcas comerciales son propiedad de
sus respectivos propietarios.
Product availability, specifications,
and compliances are subject to
change without notice
La disponibilité du produit, les
spécifications et les conformités
peuvent être modifiées sans préavis
La disponibilidad de productos, las
especificaciones y los cumplimientos
están sujetos a cambio sin previo aviso
Warranties and Limitation of Liability
Please refer to www.cooperlighting.com/legal for our terms and conditions.
Garanties et limitation de responsabilité
Veuillez consulter le site www.cooperlighting.com/legal pour obtenir les conditions générales.
Garantías y Limitación de Responsabilidad
Visite www.cooperlighting.com/legal para conocer nuestros términos y condiciones.
FCC Statement
Note: This equipment has been tested and
found to comply with the limits for a Class
A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed
to provide reasonable protection against
harmful interference in a residential
installation. This equipment generates uses
and can radiate radio frequency energy
and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off an on, the user is
encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving
antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet
on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced
radio/TV technician for help.
Declaración de la FCC
Nota: El equipo ha sido probado y cumple
con los límites para un dispositivo digital de
Clase A, de conformidad con la parte 15 de
las Normas de la FCC. Estos límites están
diseñados para proporcionar una protección
razonable contra las interferencias dañinas
en una instalación residencial. Este equipo
genera usos y puede emitir energía de
radiofrecuencia y si no se instala y utiliza de
acuerdo con las instrucciones, puede causar
interferencia dañina en las comunicaciones de
radio. Sin embargo, no se puede garantizar
que dicha interferencia no ocurra en una
instalación determinada. Si este equipo causa
interferencia dañina en la recepción de radio
o televisión, lo que puede determinarse
apagando y encendiendo el equipo, se
recomienda al usuario que intente corregir
la interferencia mediante una o más de las
siguientes medidas:
Reorientar o reubicar la antena receptora.
Aumentar la separación entre el equipo y
el receptor.
Conectar el equipo a una toma de
corriente en un circuito diferente al que
está conectado el receptor
Consultar con el distribuidor o con un
técnico de radio/TV experimentado para
obtener ayuda.
Énoncé de la FCC
Remarque: Cet équipement a été mis à l’essai
et déclaré conforme aux limites établies
pour un dispositif numérique de catégorieA
en vertu de la section15 des règlements
de la FCC. Ces limites sont conçues pour
assurer une protection raisonnable contre
tout brouillage nuisible dans une installation
résidentielle. Cet équipement produit, utilise,
et peut émettre des ondes radioélectriques ;
s’il n’est pas installé et utilisé conformément
aux instructions, il peut créer des parasites
nuisibles aux communications radio.
Cependant, il n’existe aucune garantie que les
interférences ne se produiront pas avec une
installation particulière. Si ce matériel cause
des brouillages préjudiciables à la réception
de la radio ou de la télévision qui peuvent
être déterminés en mettant le matériel hors
tension et sous tension, l’utilisateur est
invité à essayer de corriger ce brouillage au
moyen de l’une ou de plusieurs des mesures
suivantes:
Réorientez ou déplacez l’antenne
réceptrice.
Augmentez la distance entre l’équipement
et le récepteur.
Branchez l’équipement sur une prise de
courant d’un circuit différent de celui
auquel le récepteur est branché.
Communiquez avec le détaillant ou un
technicien en radio/télé expérimenté pour
obtenir de l’aide.

Transcripción de documentos

Brand Logo reversed out of black IB500002EN INS # Installation Instructions – Prevail / USSL Instructions d’installation – Prevail / USSL Instrucciones de instalación – Prevail / USSL WARNING Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved. Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at fuse or circuit breaker. Risk of Fire- Refer to product label for specific minimum supply conductor requirements. Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing. Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly. Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product. NOTICE: Green ground wire provided in proper location. Do not relocate. ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, complete with original packing must be retained. Safety: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and maintained according to the following recommendations. Regulatory Information: This equipment has been test and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Installation Instructions – Prevail / USSL INSTALLATION Split Washer This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation instructions specific to the catalog part that you ordered. Note: Care must be taken not to set lighting fixture down on optical lenses or lift the fixture by the lens. Washer 1/2” Bolt 1/2” Nut Tools Required Washer Ratchet, 3/4” socket, 3/4” wrench, #2 Phillips head screw driver and torque wrench. Pole Mount Arm (Figure 1. - Figure 5.) 1. Pole mounting arm is designed for a square or round pole. Round pole installation will require the mounting arm break away tabs to be removed. Grab break away tab with pliers and break-away the tab. (Figure 1.) 2. Mount the arm to the round or square pole using the provided 1/2” x 1-3/4” long bolts and nuts as shown. Torque bolts to 40 foot-lbs. (55 N-M). (Figure 2.) 3. Fold fixtures wires tightly towards fixture door when sliding fixture on to mounting arm. Tighten the center phillips head screw to 20 in-lbs. (2.3 N-M). (Figure 3.) 4. • Supply side neutral wire to white luminaire lead. • Supply side line voltage wire to black luminaire lead. Install arm cover and tighten phillips head screws to 20 in-lbs. (2.3 N-M). Note: Ensure the luminaire supply leads do not get pinched between cover and mounting arm. (Figure 5.) 6. Center Phillips Head Screw And Tighten to 20 in-lbs. (2.3N-M) Close-Up View Make wire connections inside the mounting arm. Refer to wire diagram for power connections. Connect the supply wires to appropriate luminaire leads: (Figure 4.) • Supply side ground wire to green luminaire lead. 5. Figure 2. Install pole cap after completion of luminaire installation and wiring. Figure 3. Line (Black) Black White Common (Black 480V) White (Black 480V) Green Ground Fixture Green Ground 9/16” (14.3mm) Diameter Hole and Slot Figure 4. 7/8” (22mm) 4-7/8” (124mm) Cover Plate Screws. Tighten to 20 in-lbs (2.3N-M) For Round Pole Installations, Break away Tabs Align Cover Tabs With Arm Slots Figure 1. 2 Cooper Lighting Solutions Figure 5. IB500002EN Installation instructions Installation Instructions – Prevail / USSL Tools required #2 Phillips head screw driver, torque wrench. Wall Plate Note: Hardware and tools to mount wall plate to wall not supplied. 6.00 ] [152.40 5.12 5] [130.0 7.12 8.00 [180.85] [203.20] Wall Mount (Figure 6.) 1. Pull the supply wires out of junction box (not supplied) and through the large hole in the center of the wall plate. 2. Secure attachment plate to the wall using four bolts (not included). 3. Follow instructions step 3 through 5 from pole mount arm configuration. .44 dia [11.20] 6x8 Plate Size Wireway (Center Hole) Figure 6. Tools required 1/4” Allen wrench, #2 Phillips head screw driver, torque wrench, drill and 7/16” drill bit. Mast Arm Mount (Figure 7. and Figure 8.) Mast Arm Pole 1. Slip the mast arm mounting assembly over the mast arm (making sure not to pinch any supply leads). Make sure the mast arm is fully seated into the mast arm adapter as it should bottom out against the adapter. 2. Secure the mast arm adapter to the mast arm with the (4) 3/8-16 x 3/8” set screws. Level the mast arm adapter while tightening the set screws. Torque to 120 in-lbs. 3. Drill a 7/16” hole through the mast arm and install the 3/8” bolt and nut. Use care when drilling this hole so as not to damage any wires within the mast arm. Torque to 120 in-lbs. 4. Open fixture door by loosening the (4) Phillips head screws (or thumb screws if supplied) on the door. (Figure 8.) 5. Remove wire grommet for fixture wires at the back of the fixture. (Figure 8.) 6. Fold fixtures wires and mast arm adapter wires out of the way and slide fixture on to the mast arm adapter. Tighten the three phillips head screws to 20 in-lbs. (2.3 N-M), and install the plastic plug over the center screw. (Figure 7.) 7. Make wire connections inside the fixture. Refer to wire diagram for power connections. Connect the supply wires to appropriate luminaire leads: (Figure 4.) (2” Tenon Arm) Level Surface Set Screws (Torque to 120 in-lbs.) 3/8” Bolt Figure 7. Wire Grommet • Supply side ground wire to green luminaire lead. Open Fixture Door • Supply side neutral wire to white luminaire lead. • Supply side line voltage wire to black luminaire lead. 8. Tighten to 20 in-lbs. Figure 8. Tuck wires into the fixture and install fixture door. Tighten the (4) fixture door screws to 20 in-lbs. (or tighten door thumb screws). Cooper Lighting Solutions IB500002EN Installation instructions 3 Installation Instructions – Prevail / USSL Tools required #2 Phillips head screw driver and pliers. House Side Shield (Figure 9. and Figure 10.) 1. Front of Fixture Optic Plastic Pins Remove plastic push pins on back side of optic. (Figure 9.) Pole Side of Fixture Note: The optics are permanently secured to the fixture. DO NOT try to remove the optics. The optics are not rotatable. 2. Install house side shield with provided #10 x 1/2” Phillips screws. Tighten until house side shield is snug. Do not over tighten. Figure 9. Note: House side shield must ONLY be installed on the back side of the optics as shown. DO NOT install on the other side of the optic. (Figure 10.) House Side Shield for rectangle shaped optics (Figure 11.) 1. House Side Shield Front of Fixture Remove the six torx type screws around the optics. Pole Side of Fixture Note: The optics are permanently secured to the fixture. DO NOT try to remove the optics. The optics are not rotatable. 2. Place House Side shield over the optics. All six screw holes will align with the optic if the House Side Shield is installed correctly. Figure 10. Note: The light will shine out of the rounded portion of the lens. The sharp vertical portion of the lens is the house side of the lens. 3. (6) Torx type screws Re-install all six torx screws per the rectangle optic(s) on your fixture. Torque to 10 to 15 in-lbs. Photocontrol Orientation (If Equipped) (Figure 12.) Note: The orientation procedure is only required for photocontrols which specifically require the cell to be aimed north. Otherwise pre-selected factory orientation will function properly. Follow the directions recommended by the photocontrol supplier for proximity to light sources. Lighted signs, building surface reflection, floodlights, tree branches, etc. may affect final position of the photocontrol. 1. Loosen the two screws to allow rotation of the receptacle. 2. Insert screwdriver into center slot and rotate receptacle until indicator arrow points north. 3. Retighten screws. 4. Insert the photoelectric control (or shorting cap) into receptacle and twist into locked position. Figure 11. Insert Flat Head and Rotate Note: The photocontrol (not included) must contain a soft, resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle. Note: Always use a photocontrol rated for 120V to 277V. Fixtures ordered with 347V or 480V power connection will use a 120V to 277V photocontrol. Fixture is wired with photocontrol after transformer (347V and 480V only). 4 Cooper Lighting Solutions IB500002EN Installation instructions Screws #10 x 1/2” Loosen Screws Figure 12. House Side Shield Instructions d’installation – Prevail / USSL AVERTISSEMENT Risque d’incendie, de décharge électrique, de coupure ou d’autres accidents de personne – L’installation et l’entretien de ce produit doivent être effectués par un électricien qualifié. Ce produit doit être installé conformément aux règles d’installation en vigueur par une personne familière avec la construction et le fonctionnement du produit, ainsi qu’avec les risques inhérents. Risque d’incendie et de décharge électrique – Assurez-vous que l’alimentation électrique est HORS TENSION avant de commencer l’installation ou de tenter d’en faire l’entretien. Mettez l’alimentation électrique hors tension depuis le fusible ou le disjoncteur. Risque d’incendie – Consultez l’étiquette du produit pour connaître les exigences minimums du conducteur d’alimentation. Risque de brûlure – Débranchez la source d’alimentation et laissez refroidir le luminaire avant de procéder à son entretien ou à sa manipulation. Risques de blessures – Le luminaire peut être endommagé et/ou instable s’il n’est pas installé correctement. La désobéissance aux instructions suivantes représente un risque de blessures graves ou mortelles et de dommages matériels. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit. AVIS : Le fil de mise à la terre vert se trouve au bon endroit. Ne le déplacez pas. ATTENTION Service de réception : Veuillez fournir une description réelle de tout manque ou de tout dommage constaté à la réception du luminaire. Les réclamations contre le transporteur (chargement partiel) doivent être déposées directement auprès dudit transporteur. Les réclamations d’avaries occultes doivent être faites dans les 15 jours suivant la réception. Tout matériel endommagé doit être entièrement conservé avec son emballage d’origine. Sécurité : Le câblage du luminaire doit être conforme au Code national de l’électricité, aux lois et ordonnances locales en vigueur. Une mise à la terre adéquate est requise afin d’assurer votre sécurité. Respectez soigneusement la procédure de mise à la terre du chapitre d’installation. APPLICATIONS : ce luminaire a été conçu pour l’éclairage extérieur et ne doit pas être utilisé dans un endroit peu ventilé ou dans des enceintes à haute température ambiante. Il doit être rangé dans un endroit sec en attendant son installation. N’exposez pas le luminaire à la pluie, à la poussière ou à d’autres conditions ambiantes avant l’installation et l’insertion de l’interrupteur photo-électrique ou de la fiche de mise en court-circuit (si équipés). Pour de meilleurs résultats, respectez les recommandations d’installation et d’entretien suivantes. Renseignements légaux : Cet équipement a été mis à l’essai et déclaré conforme aux limites établies pour un dispositif numérique de catégorie A en vertu de la section 15 des règlements de la FCC. Son fonctionnement est assujetti aux deux conditions suivantes : 1) cet appareil ne doit pas provoquer d’interférences nuisibles et 2) cet appareil doit accepter toutes les interférences reçues, même celles qui pourraient provoquer un fonctionnement indésirable. Cooper Lighting Solutions IB500002EN Instructions d’installation 5 Instructions d’installation – Prevail / USSL INSTALACIÓN Rondelle fendue Esta luminaria se ha enviado completa con una de las varias opciones de montaje. Siga las instrucciones de instalación específicas para la pieza que haya solicitado del catálogo. Rondelle Nota: Se deben tomar precauciones para no bajar la luminaria sobre las lentes ópticas ni levantarla en el área de la lente. Boulon de 1,27 cm (1/2 po) Rondelle Herramientas necesarias Écrou de 1,27 cm (1/2 po) Trinquete, portacasquillos de 3/4 pulgadas, llave de 3/4 pulgadas, destornillador cabeza Phillips n.° 2 y llave de torsión. Figura 2. Brazo para montaje en poste (Figura 1. - Figura 5.) 1. El brazo para montaje en postes está diseñado para un poste cuadrado o redondo. Para instalar la luminaria en un poste redondo se deberán retirar las lengüetas troqueladas del brazo de montaje. Sujete la lengüeta troquelada con unas pinzas y despréndala. (Figura 1.) 2. Monte el brazo sobre el poste redondo o cuadrado con los pernos de 1/2” x 1-3/4” y las tuercas incluidos como se indica. Ajuste los pernos con un torque de 40 pies-lb. (55 Nm). (Figura 2.) 3. Doble los cables de la luminaria hacia la puerta de la luminaria cuando deslice la luminaria hacia el brazo de montaje. Ajuste el tornillo Phillips central hasta 20 lb-pulg. (2,3 Nm). (Figura 3.) 4. Conecte los cables en el interior del brazo de montaje. Consulte el diagrama de cableado para conocer las conexiones de la alimentación. Conecte los cables de alimentación a los conectores adecuados de la luminaria: (Figura 4.) Tornillo Phillips central y ajústelo hasta 20 pulg.-lb (2.3 N-M) Vista de cerca Figura 3. Línea (Negro) • Cable de conexión a tierra del lado de la alimentación con el terminal verde de la luminaria. • Cable neutro del lado de la alimentación con el terminal blanco de la luminaria. • Cable de tensión de línea del lado de la alimentación con el terminal negro de la luminaria. Negro Blanco Común (Negro 480 V) Blanco (Negro 480 V) Verde Tierra Verde Tierra Luminaria 9/16” (14,3 mm) Ranura y orificio de Figura 4. 7/8” (22 mm) de diámetro Tornillos de la placa de la cubierta Ajuste hasta 20 pulg.-lb (2,3 N-M) 4-7/8” (124 mm) Para instalaciones en postes redondos, desprenda las lengüetas Alinee las lengüetas de la cubierta con las ranuras de los brazos Figura 1. 6 Cooper Lighting Solutions Figura 5. IB500002EN Instructions d’installation Instructions d’installation – Prevail / USSL 5. Instale la cubierta del brazo y ajuste los tornillos Philips con un torque de 20 pulg.-lb. (2,3 Nm). Nota: Asegúrese de que los terminales del lado de la alimentación de la luminaria no queden “mordidos” ente la cubierta y el brazo de montaje. (Figura 5.) 6. Coloque la tapa superior del poste luego de finalizar la instalación y el cableado de la luminaria. 7. Conecte los cables en el interior de la luminaria. Consulte el diagrama de cableado para conocer las conexiones de la alimentación. Conecte los cables de alimentación a los conectores adecuados de la luminaria: (Figura 4.) Placa para pared Herramientas necesarias 6,00 ] [152,40 5,12 5] [130,0 Tornillo cabeza Phillips n.° 2, llave de torsión. 0,44 de diámetro [11,20] 7,12 8,00 [180,85] [203,20] Nota: Los accesorios y las herramientas para colocar la placa de pared en la pared no están incluidos. Montaje en pared (Figura 6.) 1. Tire de los cables de alimentación hacia afuera de la caja de derivación (no incluida) y a través del orificio amplio en el centro de la placa de pared. Tamaño de la placa 6 x 8 2. Asegure la placa de sujeción a la pared utilizando cuatro pernos (no incluidos) 3. Siga las instrucciones del paso 3 al 5 de la configuración del brazo para montaje en poste. Conducto de cables (orificio central) Figura 6. Herramientas necesarias Llave allen de 1/4", destornillador Phillips n.° 2, llave de torsión, taladro y broca para taladro de 7/16". Poste del brazo mástil (Brazo espiga de 2") Montaje en brazo del mástil (Figura 7. y Figura 8.) 1. 2. Deslice la unidad de montaje para el brazo del mástil sobre este último (asegurándose de no apretar ninguno de los cables de alimentación). Asegúrese de que el brazo del mástil esté totalmente apoyado en el adaptador para el brazo del mástil, ya que debería quedar contra el adaptador. Asegure el adaptador del brazo mástil al brazo con los (4) tornillos de sujeción de 3/8-16 x 3/8". Nivele el adaptador del brazo del mástil mientras ajusta los tornillos de sujeción. Ejerza torsión a 120 pulg./lb. Superficie a nivel Tornillos de sujeción (Ajuste hasta 120 pulg.-lb) Ajuste hasta 20 pulg.-lb (2,3 N-M). Perno de 3/8” Figura 7. 3. Perfore un orificio de 7/16" a través del brazo mástil y coloque el perno de 3/8" y la tuerca. Tenga cuidado cuando realice la perforación para no dañar ningún cable dentro del brazo mástil. Ejerza torsión a 120 pulg./lb. 4. Abra la puerta de la luminaria aflojando los (4) tornillos Phillips (o las tuercas mariposa si estuvieran incluidas) de la puerta. (Figura 8.) 5. Quite la arandela aislante en la parte trasera para los cables de la luminaria. (Figura 8.) 6. Pliegue los cables de las luminarias y los cables del adaptador para brazo mástil para sacarlos del camino y deslice la luminaria sobre el adaptador para el brazo mástil. Ajuste los tres tornillos Phillips hasta 20 pulg. libras (2.3 N-M) e instale el tapón de plástico sobre el tornillo central. (Figura 7.) Arandela aislante para cables Abra la puerta de la luminaria Figura 8. Cooper Lighting Solutions IB500002EN Instructions d’installation 7 Instructions d’installation – Prevail / USSL • Le fil de mise en terre provenant de l’alimentation avec le fil vert du luminaire. • Le fil neutre provenant de l’alimentation avec le fil blanc du luminaire. • Le fil de tension provenant de l’alimentation avec le fil noir du luminaire. 5. Introduisez les fils dans le luminaire et installez la porte du luminaire. Serrez les (4) vis de la porte du luminaire à 2,3 Nm (20 po-lb) (ou serrez les vis à ailettes). 3. Resserrez les vis. 4. Insérez l'interrupteur photoélectrique (ou fiche de mise en court-circuit) dans le réceptacle et tournez-le pour le verrouiller en place. Remarque: La cellule photoélectrique (non fournie) doit être équipée d'un joint souple élastique situé sur la surface inférieure afin d'assurer l'étanchéité avec le connecteur. Remarque: Utilisez toujours une cellule photoélectrique d'une capacité de 120 V à 277 V. Les luminaires commandés avec une connexion électrique de 347 V ou de 480 Protecteur côté maison (Figure 9. et Figure 10.) V nécessiteront une cellule photoélectrique de 120 1. Retirez les barrettes à ressort en plastique qui se trouvent derrière V à 277 V. Le luminaire est câblé avec une cellule le dispositif optique. (Figure 9.) photoélectrique après le transformateur (347 V et 480 V seulement). Remarque: Les dispositifs optiques sont fixés de manière permanente au luminaire. N'essayez PAS de les retirer. Les Côté poteau du luminaire dispositifs optiques ne sont pas remplaçables. Dispositif Outillage nécessaire Tournevis cruciforme n° 2 et pince. 2. Installez les protecteurs côté maison avec les vis à tête hexagonale #10 x 12,7 mm (1/2 po) fournies. Serrez jusqu'à ce que le protecteur côté maison soit bien fixé. Ne serrez pas trop. Remarque: Le protecteur côté maison doit UNIQUEMENT être installé à l'arrière du dispositif optique, tel qu'illustré. NE l'installez PAS sur l'autre côté du dispositif optique. (Figure 10.) Protecteur côté maison pour les dispositifs optiques rectangulaires (Figure 11) 1. Retirez les six vis de type Torx autour des dispositifs optiques Remarque: Les dispositifs optiques sont fixés de manière permanente au luminaire. N’essayez PAS de les retirer. Les dispositifs optiques ne peuvent pas être tournés. 2. Barrettes en plastique Devant du luminaire Figura 9. Vis n° 10 x 12,7 mm (1/2 po) Devant du luminaire Protecteur côté maison Figura 10. Vis de type Torx Réinstallez les six vis de type Torx par dispositif optique rectangulaire sur votre luminaire. Serrez à un couple de 10 à 15 lb/ po. Protecteur côté maison Orientation de la cellule photoélectrique (si le luminaire en est doté) (Figure 12) Remarque: Cette procédure ne vise que les cellules photoélectriques qui doivent absolument être orientées vers le nord. Dans les autres cas, les réglages définis en usine les rendront parfaitement fonctionnels. Respectez les instructions du fournisseur de la cellule photoélectrique lorsqu'elle se trouve à proximité de sources d'éclairage. La présence de panneaux lumineux, de projecteurs et de branches d'arbres, la réflexion lumineuse sur les surfaces d'immeubles, etc., peuvent influencer la position finale de la cellule photoélectrique. 1. Desserrez les deux vis pour permettre la rotation de la prise. 2. Insérez un tournevis dans la fente centrale pour faire tourner le connecteur jusqu'à ce que la flèche pointe vers le nord. 8 Côté poteau du luminaire Placez le protecteur côté maison sur les dispositifs optiques. Les six trous de vis s’aligneront avec le dispositif optique si le protecteur côté maison est correctement installé. Remarque: La lumière sortira de la partie arrondie de l’objectif. La partie verticale tranchante de la lentille correspond au côté maison de la lentille. 3. optique Cooper Lighting Solutions IB500002EN Instructions d’installation Figura 11. Insérez la vis à tête plate puis tournez Desserrez les vis Figura 12. Instrucciones de instalación – Prevail / USSL ADVERTENCIA Riesgo de incendio, descarga eléctrica, cortes u otros riesgos de accidentes: la instalación y el mantenimiento de este producto deben ser realizados por un electricista calificado. Una persona con conocimientos sobre la construcción y el funcionamiento del producto y los riesgos implicados debe instalar este producto de conformidad con el código de instalación aplicable. Riesgo de incendio y descarga eléctrica: asegúrese de que la alimentación eléctrica esté APAGADA antes de comenzar la instalación o intentar realizar cualquier tipo de mantenimiento. Desconecte la alimentación eléctrica en el fusible o cortacircuitos. Riesgo de incendio: consulte la etiqueta del producto para conocer los requisitos mínimos específicos del conductor de suministro. Riesgo de quemadura: desconecte la alimentación y permita que la luminaria se refresque antes de manipularla o repararla. Riesgo de lesiones personales: la luminaria puede dañarse o desestabilizarse de no instalarla correctamente. El incumplimiento de estas instrucciones puede provocar la muerte, lesiones corporales graves y daños materiales. RENUNCIA DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan derivarse de la instalación, manipulación o uso incorrecto, descuidado o negligente de este producto. AVISO: El tornillo de puesta a tierra verde ya está ubicado correctamente. No lo cambie de ubicación. ATENCIÓN Departamento de Recepción: Observe que la descripción real de la luminaria no carezca de piezas ni presente daños notorios al momento de su entrega. Presente el reclamo directamente al transportista de carga por envíos de carga ligera (LTL). Los reclamos por daños ocultos deben presentarse dentro de los 15 días posteriores a la entrega del producto. Se debe guardar todo el material dañado, junto con el embalaje original. Seguridad: Esta luminaria debe cablearse de acuerdo con el Código Eléctrico Nacional y los códigos y ordenanzas locales aplicables. Se requiere una conexión a tierra adecuada para garantizar la seguridad personal. Observe cuidadosamente el procedimiento de conexión a tierra en la sección de instalación. APLICACIONES: Este accesorio de iluminación está diseñado para servicios de iluminación al aire libre y no debe utilizarse en áreas de ventilación limitada o en lugares cerrados a alta temperatura ambiente. Debe almacenarse en un lugar seco antes de la instalación. No exponga el accesorio de iluminación a la lluvia, el polvo u otras condiciones ambientales antes de la instalación e inserción del control fotográfico o la tapa de cortocircuito (si está equipado). Los mejores resultados se obtendrán si se instala y se mantiene de acuerdo con las siguientes recomendaciones. Información reglamentaria: Este equipo ha sido probado y cumple con los límites de un dispositivo digital de Clase A, de conformidad con la parte 15 de las Normas de la FCC. La operación está sujeta a las siguientes dos condiciones: (1) Que este dispositivo no produzca interferencia dañina y (2) que este dispositivo debe aceptar cualquier interferencia recibida, incluida aquella que pueda provocar un funcionamiento no deseado. Cooper Lighting Solutions IB500002EN Instructions d’installation 9 Instrucciones de instalación – Prevail / USSL INSTALACIÓN Arandela ranurada Esta luminaria se ha enviado completa con una de las varias opciones de montaje. Siga las instrucciones de instalación específicas para la pieza que haya solicitado del catálogo. Nota: Se deben tomar precauciones para no bajar la luminaria sobre las lentes ópticas ni levantarla en el área de la lente. Arandela Perno de 1/2” Arandela Herramientas necesarias Tuerca de 1/2” Trinquete, portacasquillos de 3/4 pulgadas, llave de 3/4 pulgadas, destornillador cabeza Phillips n.° 2 y llave de torsión. Brazo para montaje en poste (Figura 1. - Figura 5.) 1. El brazo para montaje en postes está diseñado para un poste cuadrado o redondo. Para instalar la luminaria en un poste redondo se deberán retirar las lengüetas troqueladas del brazo de montaje. Sujete la lengüeta troquelada con unas pinzas y despréndala. (Figura 1.) 2. Monte el brazo sobre el poste redondo o cuadrado con los pernos de 1/2” x 1-3/4” y las tuercas incluidos como se indica. Ajuste los pernos con un torque de 40 pies-lb. (55 Nm). (Figura 2.) 3. Doble los cables de la luminaria hacia la puerta de la luminaria cuando deslice la luminaria hacia el brazo de montaje. Ajuste el tornillo Phillips central hasta 20 lb-pulg. (2,3 Nm). (Figura 3.) 4. Conecte los cables en el interior del brazo de montaje. Consulte el diagrama de cableado para conocer las conexiones de la alimentación. Conecte los cables de alimentación a los conectores adecuados de la luminaria: (Figura 4.) Figura 2. Tornillo Phillips central y ajústelo hasta 20 pulg.-lb (2.3 N-M) Vista de cerca Figura 3. Línea (Negro) • Cable de conexión a tierra del lado de la aliment ación con el terminal verde de la luminaria. • Cable neutro del lado de la alimentación con el terminal blanco de la luminaria. • Cable de tensión de línea del lado de la alimentación con el terminal negro de la luminaria. Negro Blanco Común (Negro 480 V) Blanco (Negro 480 V) Verde Tierra Verde Tierra Luminaria 9/16” (14,3 mm) Ranura y orificio de Figura 4. 7/8” (22 mm) de diámetro Tornillos de la placa de la cubierta Ajuste hasta 20 pulg.-lb (2,3 N-M) 4-7/8” (124 mm) Para instalaciones en postes redondos, desprenda las lengüetas Alinee las lengüetas de la cubierta con las ranuras de los brazos Figura 1. 10 Cooper Lighting Solutions Figura 5. IB500002EN Instructions d’installation Instrucciones de instalación – Prevail / USSL 5. Instale la cubierta del brazo y ajuste los tornillos Philips con un torque de 20 pulg.-lb. (2,3 Nm). Nota: Asegúrese de que los terminales del lado de la alimentación de la luminaria no queden “mordidos” ente la cubierta y el brazo de montaje. (Figura 5.) 6. Coloque la tapa superior del poste luego de finalizar la instalación y el cableado de la luminaria. 7. Conecte los cables en el interior de la luminaria. Consulte el diagrama de cableado para conocer las conexiones de la alimentación. Conecte los cables de alimentación a los conectores adecuados de la luminaria: (Figura 4.) Placa para pared Herramientas necesarias 6,00 ] [152,40 5,12 5] [130,0 Tornillo cabeza Phillips n.° 2, llave de torsión. 0,44 de diámetro [11,20] 7,12 8,00 [180,85] [203,20] Nota: Los accesorios y las herramientas para colocar la placa de pared en la pared no están incluidos. Montaje en pared (Figura 6.) 1. Tire de los cables de alimentación hacia afuera de la caja de derivación (no incluida) y a través del orificio amplio en el centro de la placa de pared. Tamaño de la placa 6 x 8 2. Asegure la placa de sujeción a la pared utilizando cuatro pernos (no incluidos) 3. Siga las instrucciones del paso 3 al 5 de la configuración del brazo para montaje en poste. Conducto de cables (orificio central) Figura 6. Herramientas necesarias Llave allen de 1/4", destornillador Phillips n.° 2, llave de torsión, taladro y broca para taladro de 7/16". Poste del brazo mástil (Brazo espiga de 2") Montaje en brazo del mástil (Figura 7. y Figura 8.) 1. 2. Deslice la unidad de montaje para el brazo del mástil sobre este último (asegurándose de no apretar ninguno de los cables de alimentación). Asegúrese de que el brazo del mástil esté totalmente apoyado en el adaptador para el brazo del mástil, ya que debería quedar contra el adaptador. Asegure el adaptador del brazo mástil al brazo con los (4) tornillos de sujeción de 3/8-16 x 3/8". Nivele el adaptador del brazo del mástil mientras ajusta los tornillos de sujeción. Ejerza torsión a 120 pulg./lb. Superficie a nivel Tornillos de sujeción (Ajuste hasta 120 pulg.-lb) Ajuste hasta 20 pulg.-lb (2,3 N-M). Perno de 3/8” Figura 7. 3. Perfore un orificio de 7/16" a través del brazo mástil y coloque el perno de 3/8" y la tuerca. Tenga cuidado cuando realice la perforación para no dañar ningún cable dentro del brazo mástil. Ejerza torsión a 120 pulg./lb. 4. Abra la puerta de la luminaria aflojando los (4) tornillos Phillips (o las tuercas mariposa si estuvieran incluidas) de la puerta. (Figura 8.) 5. Quite la arandela aislante en la parte trasera para los cables de la luminaria. (Figura 8.) 6. Pliegue los cables de las luminarias y los cables del adaptador para brazo mástil para sacarlos del camino y deslice la luminaria sobre el adaptador para el brazo mástil. Ajuste los tres tornillos Phillips hasta 20 pulg. libras (2.3 N-M) e instale el tapón de plástico sobre el tornillo central. (Figura 7.) Arandela aislante para cables Abra la puerta de la luminaria Figura 8. Cooper Lighting Solutions IB500002EN Instructions d’installation 11 Instrucciones de instalación – Prevail / USSL • Cable de conexión a tierra del lado de la aliment ación con el terminal verde de la luminaria. Óptica • Cable neutro del lado de la alimentación con el terminal blanco de la luminaria. • Cable de tensión de línea del lado de la aliment ación con el terminal negro de la luminaria. 5. Introduzca los cables en la luminaria y coloque la puerta. Ajuste los (4) tornillos de la puerta de la luminaria hasta 20 pulg.-lb (o ajuste los tornillos mariposa de la puerta). Herramientas necesarias Tachuelas de plástico Frente de la luminaria Lado del poste de la luminaria Figura 9. Tornillo cabeza Phillips n.° 2 y pinzas. Pantalla de cuatro lados Pantalla lateral del alojamiento (Figura 9. y Figura 10.) 1. Quite las tachuelas de plástico en el lado de la óptica. (Figura 9.) Nota: Las ópticas se fijan permanentemente a la luminaria. NO intente quitar las ópticas. Las ópticas no se pueden girar. 2. Instale la pantalla lateral del alojamiento con los tornillos Phillips n.° 10 x 1/2". Ajuste hasta que la pantalla lateral del alojamiento esté apretada. No la sobreajuste. Frente de la luminaria Figura 10. Nota: La pantalla lateral del alojamiento SOLO se debe instalar en el lado trasero de la óptica, como se muestra. NO instalar en el otro lado de la óptica. (Figura 10.) Pantalla lateral del alojamiento para las ópticas en forma de rectángulo (Figura 11). 1. Retire los seis tornillos tipo Torx que se encuentran alrededor de las ópticas. Remarque: Las ópticas están fijas de manera permanente a la luminaria. NO intente quitar las ópticas. Las ópticas no son giratorias. 2. Coloque la pantalla lateral del alojamiento sobre las ópticas. Los seis orificios para tornillos se alinearán con la óptica si la pantalla lateral del alojamiento se instala correctamente Remarque: La luz brillará desde la parte redondeada de la lente. La porción vertical afilada de la lente es el lado de la lente orientado hacia el alojamiento. 3. Vuelva a instalar los seis tornillos Torx según la(s) óptica(s) rectangular(es) en su luminaria. Apriete con una fuerza de 10 a 15 pulg./lb (1,13 a 1,69 N·m). Orientación del fotocontrol (si estuviera incluido) (Figura 12.) Nota: El procedimiento de orientación solo es necesario para los fotocontroles que requieren, específicamente, que la celda apunte hacia el norte. De lo contrario, la orientación seleccionada previamente en fábrica funcionará adecuadamente. 12 Cooper Lighting Solutions IB500002EN Instructions d’installation Tornillos n.° 10 x 1/2" Lado del poste de la luminaria Siga las instrucciones recomendadas por el proveedor del fotocontrol respecto de su proximidad a las fuentes de iluminación. La posición final del fotocontrol puede verse afectada por señalizaciones iluminadas, reflexiones en las superficies del edificio, reflectores, ramas de árboles, etc. 1. Afloje los dos tornillos para poder girar el receptáculo. 2. Inserte el destornillador en la ranura central y gire el receptáculo hasta que la flecha de indicación apunte hacia el norte. 3. Vuelva a ajustar los tornillos. 4. Inserte el control fotoeléctrico (o el tapón de cortocircuito) en el receptáculo y gírelo a la posición de bloqueo. Nota: El fotocontrol (no incluido) debe contener una junta suave y elástica ajustada a la parte inferior de su superficie para garantizar un apropiado sellado hermético entre el control y el receptáculo. Tornillos tipo Torx Pantalla lateral del alojamiento Figure 11. Introduzca el destornillador de cabeza plana y hágalo girar Nota: Siempre utilice un fotocontrol apto para 120 V a 277 V. Las luminarias que solicite con conexión de alimentación de 347 V o 480 V usarán un fotocontrol de 120 V a 277 V. La luminaria se conecta al fotocontrol después del transformador (347 V y 480 V solamente). Afloje los tornillos Figura 12. 13 FCC Statement Énoncé de la FCC Declaración de la FCC Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures: Remarque : Cet équipement a été mis à l’essai et déclaré conforme aux limites établies pour un dispositif numérique de catégorie A en vertu de la section 15 des règlements de la FCC. Ces limites sont conçues pour assurer une protection raisonnable contre tout brouillage nuisible dans une installation résidentielle. Cet équipement produit, utilise, et peut émettre des ondes radioélectriques ; s’il n’est pas installé et utilisé conformément aux instructions, il peut créer des parasites nuisibles aux communications radio. Cependant, il n’existe aucune garantie que les interférences ne se produiront pas avec une installation particulière. Si ce matériel cause des brouillages préjudiciables à la réception de la radio ou de la télévision qui peuvent être déterminés en mettant le matériel hors tension et sous tension, l’utilisateur est invité à essayer de corriger ce brouillage au moyen de l’une ou de plusieurs des mesures suivantes : Nota: El equipo ha sido probado y cumple con los límites para un dispositivo digital de Clase A, de conformidad con la parte 15 de las Normas de la FCC. Estos límites están diseñados para proporcionar una protección razonable contra las interferencias dañinas en una instalación residencial. Este equipo genera usos y puede emitir energía de radiofrecuencia y si no se instala y utiliza de acuerdo con las instrucciones, puede causar interferencia dañina en las comunicaciones de radio. Sin embargo, no se puede garantizar que dicha interferencia no ocurra en una instalación determinada. Si este equipo causa interferencia dañina en la recepción de radio o televisión, lo que puede determinarse apagando y encendiendo el equipo, se recomienda al usuario que intente corregir la interferencia mediante una o más de las siguientes medidas: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. • Réorientez ou déplacez l’antenne réceptrice. • Augmentez la distance entre l’équipement et le récepteur. • Branchez l’équipement sur une prise de courant d’un circuit différent de celui auquel le récepteur est branché. • Communiquez avec le détaillant ou un technicien en radio/télé expérimenté pour obtenir de l’aide. • Reorientar o reubicar la antena receptora. • Aumentar la separación entre el equipo y el receptor. • Conectar el equipo a una toma de corriente en un circuito diferente al que está conectado el receptor • Consultar con el distribuidor o con un técnico de radio/TV experimentado para obtener ayuda. Warranties and Limitation of Liability Please refer to www.cooperlighting.com/legal for our terms and conditions. Garanties et limitation de responsabilité Veuillez consulter le site www.cooperlighting.com/legal pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com/legal para conocer nuestros términos y condiciones. Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Canada Sales 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-501-3000 F: 905-501-3172 © 2020 Cooper Lighting Solutions All Rights Reserved Publication No. IB500002EN March 19, 2020 Cooper Lighting Solutions is a registered trademark. All trademarks are property of their respective owners. Cooper Lighting Solutions est une marque de commerce déposée. Toutes les autres marques de commerce sont la propriété de leur propriétaire respectif. Cooper Lighting Solutions es una marca comercial registrada. Todas las marcas comerciales son propiedad de sus respectivos propietarios. Product availability, specifications, and compliances are subject to change without notice La disponibilité du produit, les spécifications et les conformités peuvent être modifiées sans préavis La disponibilidad de productos, las especificaciones y los cumplimientos están sujetos a cambio sin previo aviso
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Cooper Lumark Prevail Installation Instructions Manual

Tipo
Installation Instructions Manual
Este manual también es adecuado para

en otros idiomas