5125 (9910 P18) Quick Start for IBM
®
Applications : 164201421 A
POWERWARE 5125 (9910 P18) QUICK START
FOR
IBM APPLICATIONS
NOTE The following procedure is for an IBM pSeries
Z
rack only. If you have another type of rack, contact your service
representative (see page 4).
Step 1. UPS Setup
Qty. Powerware Part Number Description
2 Mounting Handles
4 Mounting Handle Screws
2 Mounting Brackets
4 Mounting Bracket Screws
1 157604171-001 Left Fixed Mounting Rail Assembly
1 157604171-002 Right Fixed Mounting Rail Assembly
4 10-32 Clip Nuts
8 10-321/22 Pan-Head Screws
2 157604172-001 Rear Hold-Down Brackets
4 10-321/22 Flat-Head Screws
1 164201357
Powerware 4-Post Rail Kit User’s Guide
1 05147305
Powerware 5125 Two-in-One (1000–1500 VA) User’s Guide
1. Attach the supplied mounting handles to the
mounting brackets.
Align the mounting brackets with the screw holes on
the side of the UPS and secure with the supplied
screws.
NOTE The UPS and Extended Battery Modules MUST be
installed at the bottom of the rack. If placed in a rack with
existing equipment, the rack must be reconfigured to allow
the UPS installation at the bottom of the rack.
NOTE The EBMs must be installed below the UPS.
2. Install the clip nuts over the holes on the back of the
rack.
NOTE The clip nuts for the first set of rails go over the holes
in position 2 and 4. If you are installing additional rails, the
next set of clip nuts should be placed 4 and 6 holes above the
last installed clip nut.
Position 2
Position 4
Position 8
Position 10Position 10
Second Set of Clip Nuts
First Set of Clip Nuts
Powerware
®
5125 (9910 P18) Quick Start for IBM
®
Applications : 164201421 A
2
3. Secure both rails to the back of the rack with
pan-head screws. Insert the screws through the clip
nuts installed in Step 2.
4. Secure both rails to the front of the rack with
pan-head screws. Insert the screws through the
center holes of the rail.
NOTE Do not tighten the screws until the UPS or EBM is
installed.
5. Slide the UPS and any optional EBMs into the rack.
CAUTION
The UPS and EBM are heavy. A minimum of two people are
required to lift the UPS into the rack.
6. To secure the back of the UPS to the rack, loosen the
wing nut on the rear hold-down bracket and slide the
bracket over the rear of the UPS. Tighten the wing
nut.
7. Secure the front of the UPS to the rack using
flat-head screws.
Rear Hold-Down
Bracket
3
Powerware
®
5125 (9910 P18) Quick Start for IBM
®
Applications : 164201421 A
Step 2. Cord Connections
Qty. Powerware
Part Number
Description
2 60420055 IEC 320-C13 to C14, 10A Equipment Power Cords (6 ft/1.8m)
1 05147305
Powerware 5125 Two-in-One (1000–1500 VA) User’s Guide
1. If you are using a power distribution bus (PDB), plug
the equipment into the appropriate UPS output
receptacles using the interconnect cords supplied
with the IBM rack.
NOTE DO NOT protect laser printers with the UPS because
of the exceptionally high power requirements of the heating
elements.
If you are using two PDBs for redundancy, plug in
the equipment as shown.
2. Plug the output power cord (IEC 320-C13 to C-14)
into the output connector on the UPS rear panel.
3. Plug the other end of the output power cord into the
PDB.
NOTE If you are using more than one UPS in a rack, verify
that the UPS output power cords are plugged into separate
PDBs.
For additional P18 rack connection information, go to
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. To complete startup, refer to Powerware 5125
Two-in-One (1000–1500 VA) User’s Guide.
Powerware
®
5125 (9910 P18) Quick Start for IBM
®
Applications : 164201421 A
4
Step 3. Communication Options
Qty. Powerware Part
Number
Description
1 05146745-31 Powerware Software Suite CD
1 124102022-002 UPS to Server Communication Cables (DB-9 to DB-9, 6 ft/1.8m)
The following communication options are available with the
UPS:
: One server serially connected to the P18 UPS
: Network (WebServer) with the P18 UPS as a node
For additional information, go to
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Service and Support
In the United States and Canada, call 1-800-IBMSERV
(1-800-426-7378). In Europe, the Middle East, and Africa
(EMEA); Latin America; or Asia-Pacific, call the
IBM office
that services your account.
5
Guidededémarrage rapide Powerware
®
5125 (9910 P18) pour applications IBM
®
: 164201421 A
GUIDE DE DÉMARRAGE RAPIDE POWERWARE 5125 (9910 P18)
POUR APPLICATIONS IBM
REMARQUE La procédure suivante s’applique à une baie IBM pSeries
Z
uniquement. Pour tout autre type de baie, contactez
votre représentant du service (voir page 8).
Etape 1. Installation de l’onduleur
Qté Numéro de pièce
Powerware
Description
2 Poignées de montage
4 Vis de poignées de montage
2 Supports de fixation
4 Vis de supports de fixation
1 157604171-001 Ensemble de rails de montage fixes de gauche
1 157604171-002 Ensemble de rails de montage fixes de droite
4 Ecrous de clips 10-32
8 10-321/22 Vis à tête cylindrique large
2 157604172-001 Supports de fixation arrière
4 10-321/22 Vis à tête plate
1 164201357
Guidedel’utilisateur de l’ensemble de rails pour 4 postes Powerware
1 05147305
Guide de l’utilisateur Powerware 5125 deux en un (1000–1500 VA)
1. Fixez les poignées de montage fournies aux supports de
fixation.
Alignez les supports de fixation avec les trous pour
vis sur la face latérale de l’onduleur et fixez les
supports à l’aide des vis fournies.
REMARQUE Londuleur et tout Module de batterie étendu
(EBM) optionnels DOIVENT être installés dans le fond de la
baie. Si la baie contient déjà des appareils, elle doit être
réorganisée afin de permettre l’installation de l’onduleur au
fond de la baie.
REMARQUE Les EBM doivent être installés sous l’onduleur.
2. Posez les écrousdeclipssurlestrousàlarrièredela
baie.
REMARQUE Posez les écrous de clips du premier ensemble
de rails sur les trous des positions 2 et 4. Si vous installez
d’autres rails, le prochain ensemble d’écrous de clips doit
être placé 4 et 6 trous au-dessus du dernier écrou de clip
posé.
Position 2
Position 4
Position 8
Position 10Position 10
Second ensemble
d’écrous de clips
Premier ensemble
d’écrous de clips
6
Guidededémarrage rapide Powerware
®
5125 (9910 P18) pour applications IBM
®
: 164201421 A
3. Fixez les deux rails àlarrièredelabaieàlaidedevis
à tête cylindrique large. Insérez les vis dans les écrous
de clips posés à l’étape 2.
4. Fixez les deux rails à l’avant de la baie à l’aide de vis à
tête cylindrique large. Insérez les vis dans les trous
centraux du rail.
REMARQUE Ne serrez les vis que lorsque londuleur ou
l’EBM est installé.
5. Insérez l’onduleur et les EBM optionnels dans la baie.
ATTENTION
L’onduleur et l’EBM sont lourds. Deux personnes au minimum
sont requises pour soulever l’onduleur et le placer dans la
baie.
6. Pour fixer l’arrière de l’onduleur à la baie, desserrez
l’écrou papillon du support de fixation arrière et
faites glisser le support par-dessus l’arrière de
l’onduleur. Serrez l’écrou papillon.
7. Fixezlavantdelonduleuràlabaieàlaidedevi
tête plate.
Support de
fixation arrière
7
Guidededémarrage rapide Powerware
®
5125 (9910 P18) pour applications IBM
®
: 164201421 A
Etape 2. Connexion des cordons
Qté Numéro de pièce
Powerware
Description
2 60420055 Cordons d’alimentation pour appareils IEC 320-C13 vers C14, 10A (1,8m)
1 05147305
Guidedel’utilisateur Powerware 5125 deux en un (1000–1500 VA)
1. Si vous utilisez un bus de distribution d’alimentation
(PDB), raccordez vos appareils aux prises de sortie
correspondantes de l’onduleur UPS à l’aide des
cordons de raccordement fournis avec la baie IBM.
REMARQUE NE PAS protéger les imprimantes laser avec
l’onduleur car les besoins en énergie des éléments
chauffants sont exceptionnellement élevés.
Si vous utilisez deux PDB pour la redondance,
raccordez-les aux appareils comme indiqué.
2. Branchez le cordon d’alimentation de sortie
(IEC 320-C13 vers C-14) sur le connecteur de sortie
du panneau arrière de l’onduleur UPS.
3. Branchez l’autre extrémité du cordon de sortie dans
le PDB.
REMARQUE Si vous utilisez plusieurs onduleurs dans une
baie, vérifiez que les cordons d’alimentation de sortie des
onduleurs sont raccordés à des PDB distincts.
Pour des informations supplémentaires sur le
raccordement de la baie au P18, consultez le site
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. Pour effectuer la mise en route, voir Guide de
l’utilisateur Powerware 5125 deux en un
(1000–1500 VA).
8
Guidededémarrage rapide Powerware
®
5125 (9910 P18) pour applications IBM
®
: 164201421 A
Etape 3. Options de communication
Qté Numéro de pièce
Powerware
Description
1 05146745-31 CD de la Suite logicielles Powerware
1 124102022-002 Câbles de communication Onduleur vers Serveur (DB-9 vers DB-9, 1,8m)
Options de communication disponibles avec l’onduleur :
: Un serveur branché en série à l’onduleur UPS P18
: Réseau (WebServer) avec onduleur P18 en guise de
noeud
Pour des informations supplémentaires, consultez le site
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Service après-vente et assistance technique
Aux Etats-Unis et au Canada, appelez le 1-800-IBMSERV
(1-800-426-7378). En Europe, au Moyen-Orient, en Afrique,
en Amérique latine ou en Asie-Pacifique, appelez le
centre
IBM
qui est responsable de votre compte.
9
Powerware
®
5125 (9910 P18) Schnelle Inbetriebnahme für IBM
®
-Anwendungen : 164201421 A
POWERWARE 5125 (9910 P18) SCHNELLE INBETRIEBNAHME
FÜR
IBM-ANWENDUNGEN
HINWEIS Das folgende Verfahren bezieht sich nur auf ein Gestell des Typs IBM pSeries
Z
Wenn Sie eine andere Art von
Gestell verwenden, wenden Sie sich an Ihren Kundendienstmitarbeiter (siehe Seite 12).
Schritt 1: Einrichten der USV
Menge Powerware Teilenummer Bezeichnung
2 Montagegriffe
4 Schrauben für Montagegriffe
2 Halterungen
4 Schrauben für Halterungen
1 157604171-001 Links montierter Befestigungsschienensatz
1 157604171-002 Rechts montierter Befestigungsschienensatz
4 10-32 Clipsmuttern
8 10-321/22 Flachkopfschrauben
2 157604172-001 Hintere Haltebügel
4 10-321/22 Senkkopfschrauben
1 164201357
Benutzerhandbuch für Powerware Schienensatz für 4 Stützpfosten
1 05147305
Benutzerhandbuch für Powerware 5125 Two-in-One (1000 – 1500 W)
1. Mitgelieferte Montagegriffe an den Halterungen
montieren.
Die Halterungen nach den Schraubenlöchern auf der
Seite der USV ausrichten und mit den mitgelieferten
Schrauben sichern.
HINWEIS Die USV und die optionale Erweiterte
Batteriemoduls (EBMs) MÜSSEN unten in das Gestell
eingebaut werden. Beim Einbau in ein Gestell mit
vorhandenen Geräten ist das Gestell so zu konfigurieren, daß
der Einbau der USV unten in das Gestell möglich ist.
HINWEIS Die EBMs müssen unter dem USV installiert
werden.
2. Bringen Sie die Clipsmuttern über den Bohrungen
auf der Rückseite des Gestells an.
HINWEIS Die Clipsmuttern für den ersten Schienensatz
gehören über die Bohrungen in Position 2 und 4. Sind weitere
Schienen zu installieren, muss der nächste Satz Clipsmuttern
4 und 6 Bohrungen über der letzen montierten Clipsmutter
platziert werden.
.
Position 2
Position 4
Position 8
Position 10Position 10
Zweiter Satz
Clipsmuttern
Erster Satz
Clipsmuttern
10
Powerware
®
5125 (9910 P18) Schnelle Inbetriebnahme für IBM
®
-Anwendungen : 164201421 A
3. Beide Schienen an der Rückseite des Gestells mit
Flachkopfschrauben befestigen. Die Schrauben durch
die in Schritt 2 installierten Clipsmuttern einfügen.
4. Beide Schienen an der Vorderseite des Gestells mit
Flachkopfschrauben befestigen. Die Schrauben durch
die mittleren Bohrungen der Schiene stecken.
HINWEIS Die Schrauben nicht anziehen, bevor die USV
bzw. das EBM montiert ist.
5. Die USV und etwaige optionale EBMs in das Gestell
schieben.
ACHTUNG
Die USV und das EBM sind schwer. Zum Hineinheben der
USV in das Gestell sind mindestens zwei Personen
erforderlich.
6. Zur Befestigung der Rückseite der USV im Gestell
Flügelmutter am hinteren Haltebügel lösen und den
Bügel über die Rückseite der USV schieben.
Flügelmutter anziehen.
7. Vorderseite der USV mit Senkkopfschrauben am
Gestell befestigen.
Hinterer
Haltebügel
11
Powerware
®
5125 (9910 P18) Schnelle Inbetriebnahme für IBM
®
-Anwendungen : 164201421 A
Schritt 2: Kabelanschlüsse
Menge Powerware
Teilenummer
Bezeichnung
2 60420055 Gerätestromkabel (1,8m) von IEC 320-C13 zu C14, 10A
1 05147305
Benutzerhandbuch für Powerware 5125 Two-in-One (1000 – 1500 W)
1. Wenn Sie einen Stromverteilungsbus (PDB)
verwenden, schließen Sie das Gerät am
entsprechenden Ausgangsanschluss der USV an,
indem Sie die mit dem IBM-Gestell gelieferten
Verbindungskabel verwenden.
HINWEIS Laserdrucker wegen des außerordentlich hohen
Leistungsbedarfs der Heizelemente NICHT mit der USV
schützen.
Wenn Sie aus Redundanzgründen zwei PDBs
verwenden, schließen Sie die Geräte gemäß der
Abbildung an.
2. Das Netzausgangskabel (IEC 320-C13 zu C-14) in
den Ausgangsanschluss auf der Rückwand der USV
stecken.
3. Das andere Ende des Netzausgangskabels in den PDB
stecken.
HINWEIS Wenn mehrere USVs in einem Gestell verwendet
werden, ist zu prüfen, dass die Netzausgangskabel der USVs
an separaten PDBs angeschlossen sind.
Weitere Informationen zum Anschluss von P18-Gestellen
finden Sie unter
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. Informationen zum Abschließen der Inbetriebnahme
finden Sie im Benutzerhandbuch für Powerware 5125
Two-in-One (1000 – 1500 W).
12
Powerware
®
5125 (9910 P18) Schnelle Inbetriebnahme für IBM
®
-Anwendungen : 164201421 A
Schritt 3: Kommunikationsoptionen
Menge Powerware
Teilenummer
Bezeichnung
1 05146745-31 CD mit der Powerware Software-Reihe
1 124102022-002 Datenübertragungskabel USV-Server (DB-9 zu DB-9, 1,8m)
Die folgenden Kommunikationsoptionen sind für die USV
verfügbar:
: Ein seriell am USV P18 angeschlossener Server
: Netzwerk-Server (Web-Server) mit USV P18 als Knoten
Weitere Informationen finden Sie unter
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Kundendienst und Unterstützung
Rufen Sie in den Vereinigten Staaten und in Kanada
1-800-IBMSERV (1-800-426-7378) an. In Europa, im Nahen
Osten und in Afrika (EMEA) sowie in Lateinamerika oder in
Asien/im Pazifikraum rufen Sie das
IBM-Büro an, das für Ihr
Konto zuständig ist.
13
Powerware
®
5125 (9910 P18) Guida rapida per le applicazioni IBM
®
: 164201421 A
POWERWARE 5125 (9910 P18)
GUIDA RAPIDA PER LE APPLICAZIONI IBM
NOTA La procedura descritta di seguito si riferisce solo ai rack IBM pSeries
Z
Per rack di tipo diverso, è necessario rivolgersi
al il vostro rappresentante per l’assistenza (vedere la pagina 16).
Passo 1. Installazione dell’UPS
Qtà Powerware
numero parte
Descrizione
2 Maniglie per il montaggio
4 Viti per le maniglie per il montaggio
2 Staffe il montaggio
4 Viti per le staffe il montaggio
1 157604171-001 Guida di montaggio fissa sinistra
1 157604171-002 Guida di montaggio fissa destra
4 Dadi di fermo 10-32
8 Viti con testa universale 10-321/22
2 157604172-001 Staffe di bloccaggio posteriori
4 Viti con testa piatta 10-321/22
1 164201357
Kit Powerware 4, manuale per l’utente
1 05147305
Powerware 5125 Due in uno (1000–1500 VA) Manuale dell’utente
1. Collegare le maniglie di montaggio fornite alle staffe di
montaggio.
Allineare le staffe di montaggio con i fori delle viti sul
lato dell’UPS e serrarle con le viti fornite in
dotazione.
NOTA L’UPS e i Moduli batteria di espansione opzionale
DEVONO essere installati nella sezione inferiore del rack. Se
il rack contiene già altre attrezzature, è necessario
riconfigurarlo in modo da consentire l’installazione dell’UPS
nella sezione inferiore del rack.
NOTA Gli EBM devono essere installati sotto l’UPS.
2. Inserireidatidifermoneiforisulretrodelrack.
NOTA I dadi di fermo per il primo gruppo di guide devono
essere inseriti nei fori corrispondenti alle posizioni 2 e 4. Se
si installano guide aggiuntive, installare i dadi di fermo
aggiuntivi nei fori corrispondenti alle posizioni 4 e 6, sopra
l’ultimo dado di fermo installato.
.
Posizione 2
Posizione 4
Posizione 8
Secondo gruppo di dadi
Primo gruppo di dadi
Posizione 10
14
Powerware
®
5125 (9910 P18) Guida rapida per le applicazioni IBM
®
: 164201421 A
3. Bloccare entrambe le guide sul retro del rack
utilizzando le viti a testa universale. Inserire le viti
nei dadi di fermo installati nel punto 2.
4. Bloccare entrambe le guide sul lato frontale del rack
utilizzando le viti a testa universale. Inserire le viti
nei fori centrali della guida.
NOTA Serrare le viti solo dopo aver installato l’UPS
o l’EBM.
5. Far scorrere l’UPS e tutti gli EBM opzionali nel rack.
ATTENZIONE
L’UPS e l’ EBM ssono pesanti. Per spostare l’UPS è richiesto
l’intervento di almeno due persone.
6. Per bloccare il retro dell’UPS sul rack, allentare il
dado ad alette sul retro della staffa di bloccaggio e far
scorrere la staffa sul retro dell’UPS. Serrare il dado ad
alette.
7. Bloccare il lato frontale dell’UPS sul rack utilizzando
le viti a testa piatta.
Staffa di
bloccaggio
posteriore
15
Powerware
®
5125 (9910 P18) Guida rapida per le applicazioni IBM
®
: 164201421 A
Passo 2. Connessione dei cavi
Qtà Powerware
numero parte
Descrizione
2 60420055 Cavi di alimentazione apparecchiatura da IEC 320/C13 a C14, 10E (1,8 metri)
1 05147305
Powerware 5125 Due in uno (1000–1500 VA) Manuale dell’utente
1. Se si utilizza un bus per la distribuzione
dell’alimentazione (PDB), è necessario collegare
l’attrezzatura alla presa di uscita dell’UPS appropriata
utilizzando i cavi di interconnessione forniti con il rack.
NOTA NON proteggere le stampanti laser con lUPS a causa
della potenza estremamente elevata richiesta dagli elementi
riscaldanti.
Se si utilizzano due PDB a scopo di ridondanza,
effettuare le connessioni come mostrato nella figura.
2. Collegare il cavo di alimentazione in uscita (da
IEC 320-C13 a C-14) al connettore in uscita sul
pannello posteriore dell’UPS.
3. Collegare l’altra estremità del cavo di alimentazione
in uscita nel PDB.
NOTA Se si utilizzano più UPS sul rack, verificare che i cavi
di alimentazione in uscita dell’UPS siano collegati a PDB
diversi.
Per ulteriori informazioni sulla connessione dei rack P18,
visitare il sito Web
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. Per completare l’installazione, consultare la
Powerware 5125 Due in uno (1000–1500 VA) Manuale
dell’utente.
16
Powerware
®
5125 (9910 P18) Guida rapida per le applicazioni IBM
®
: 164201421 A
Passo 3. Opzioni per le comunicazioni
Qtà Powerware
numero parte
Descrizione
1 05146745-31 CD contenente il pacchetto software Powerware
1 124102022-002 Cavi di comunicazione da UPS al server (DB-9/DB-9, 1,8 metri)
Per l’UPS sono disponibili le seguenti opzioni di
comunicazione:
: Un server collegato all’UPS P18 tramite linea seriale
: Rete (WebServer) con l’UPS P18 utilizzato come nodo
Per ulteriori informazioni, consultare il sito Web
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Assistenza e supporto
Per gli Stati Uniti e Canada, chiamare il numero
1-800-IBMSERV (1-800-426-7378). In Europa, Medio Oriente
e Africa (EMEA), America Latina, o Asia del Pacifico,
chiamare il numero
Ufficio IBM, per l’assistenza clienti.
17
Powerware
®
5125 (9910 P18) - Guia Rápido para Aplicações IBM
®
: 164201421 A
POWERWARE 5125 (9910 P18) - GUIA RÁPIDO
PARA
APLICAÇÕES IBM
OBSERVAÇÃO Os procedimentos a seguir se referem somente a chassi IBM pSeries
Z
Se você tiver outro tipo de chassi,
contate a assistência técnica de sua região (consulte a página 20).
Passo 1. Configuração do no-break
Qtde. Número de referência Powerware Descrição
2 Alças de montagem
4 Parafusos para alça de montagem
2 Suportes de montagem
4 Parafusos para suportes de montagem
1 157604171-001 Conjunto do trilho de montagem fixo à esquerda
1 157604171-002 Conjunto do trilho de montagem fixo à direita
4 Porcas autotravantes 10-32
8 Parafusos philips 10-321/22
2 157604172-001 Suportes de contenção traseiros
4 Parafusos de cabeça chata 10-321/22
1 164201357
Guia do Usuário do Kit de 4 Colunas de Trilhos Powerware
1 05147305
Guia do Usuário do Powerware 5125 Two-in-One (1000–1500 VA)
1. Fixe as alças de montagem fornecidas aos suportes de
montagem.
Alinhe os suportes de montagem com os orifícios
para parafusos na parte lateral do no-break e fixe-os
com os parafusos fornecidos.
OBSERVAÇÃO O no-break e os Módulos Estendidos de
Baterias (EBMs) opcionais DEVEM ser instalados na parte
inferior do chassi. Se forem instalados em um chassi que já
contém algum equipamento, o chassi deverá ser
reconfigurado para permitir a instalação do no-break na sua
parte inferior.
OBSERVAÇÃO Os EBMs devem ser instalados abaixo do
no-break.
2. Instale as porcas autotravantes nos orifícios da parte
de trás do chassi.
OBSERVAÇÃO As porcas autotravantes destinadas ao
primeiro conjunto de trilhos devem ser instaladas nos
orifícios nas posições 2 e 4. Se você estiver instalando trilhos
adicionais, o próximo conjunto de porcas autotravantes
deveráserinstalado4e6orifíciosacimadltimaporca
instalada.
.
Posição 2
Posição 4
Posição 8
Posição 10
Segundo conjunto de
porcas autotravantes
Primeiro conjunto de
porcas autotravantes
18
Powerware
®
5125 (9910 P18) - Guia Rápido para Aplicações IBM
®
: 164201421 A
3. Fixe ambos os trilhos no fundo do chassi com
parafusos philips. Rosqueie os parafusos através das
porcas autotravantes instaladas no passo 2.
4. Fixe ambos os trilhos na parte frontal do chassi com
parafusos philips. Rosqueie os parafusos através dos
orifícios centrais do trilho.
OBSERVAÇÃO Não aperte os parafusos até que o no-break
ou o EBM esteja instalado.
5. Deslize o no-break e quaisquer EBMs opcionais para
dentro do chassi.
PERIGO
O no-break e o EBM são pesados. São necessárias pelo
menos duas pessoas para colocar o no-break no chassi.
6. Para fixar a parte de trás do no-break no chassi,
afrouxe a porca borboleta no suporte traseiro e
deslize este suporte sobre a parte traseira do
no-break. Aperte a porca borboleta.
7. Fixe a parte frontal do no-break no chassi usando
parafusos de cabeça chata.
Suporte de
contenção
traseiro
19
Powerware
®
5125 (9910 P18) - Guia Rápido para Aplicações IBM
®
: 164201421 A
Passo 2. Conexões dos cabos
Qtde. Número de referência
Powerware
Descrição
2 60420055 Cabos de alimentação do equipamento IEC 320-C13 para C14, 10A, de 1,8 m
1 05147305
Guia do Usuário do Powerware 5125 Two-in-One (1000–1500 VA)
1. Se você estiver usando um barramento de distribuição
de energia (PDB - power distribution bus), conecte o
equipamento aos receptáculos de saída apropriados
usando os cabos de ligação fornecidos com o chassi
IBM.
OBSERVAÇÃO NÃO proteja impressoras laser com o
no-break devido às exigências de energia excepcionalmente
altas dos componentes de aquecimento.
Se você estiver usando dois PDBs para conexões
redundantes, conecte o equipamento conforme
ilustrado.
2. Conecte o cabo de alimentação de saída
(IEC 320-C13 a C-14) no conector de saída, que se
encontra no painel traseiro do no-break.
3. Conecte a outra extremidade do cabo de alimentação
de saída no PDB.
OBSERVAÇÃO Se você estiver usando mais do que um
no-break em um único chassi, certifique-se de que os cabos
de alimentação de saída estejam conectados em PDBs
separados.
Para obter informações adicionais sobre conexões em
chassi P18, visite
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. Para completar o procedimento de inicialização,
consulte o Guia do Usuário do Powerware 5125
Two-in-One (1000–1500 VA).
20
Powerware
®
5125 (9910 P18) - Guia Rápido para Aplicações IBM
®
: 164201421 A
Passo 3. Opções de comunicação
Qtde. Número de referência
Powerware
Descrição
1 05146745-31 CD-ROM do Pacote de Software Powerware
1 124102022-002 Cabos de comunicação entre no-break e servidor (DB-9 para DB-9, 1,8 m)
As seguintes opções de comunicação estão disponíveis com
o no-break:
: Um servidor conectado serialmente ao no-break P18
: Em rede (WebServer), com o no-break P18 como um
dos nós
Para obter informações adicionais, visite
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Assistência e suporte
Nos Estados Unidos e no Canadá, ligue para 1-800-IBMSERV
(1-800-426-7378). Na Europa, no Oriente Médio e na África
(EMEA), na América Latina ou Ásia-Pacífico, entre em
contato com o
escritório IBM que lhe fornece assistência.
21
Inicio rápido de Powerware
®
5125 (9910 P18) para aplicaciones de IBM
®
: 164201421 A
INICIO RÁPIDO DE POWERWARE 5125 (9910 P18)
PARA APLICACIONES DE IBM
NOTA El siguiente procedimiento es solamente para un estante IBM pSeries
Z
Si tiene otro tipo de estante comuníquese con
su representante de servicio (consulte la página 24).
Paso 1. Configuración del SIE
Cant. Número de parte
de Powerware
Descripción
2 Agarraderas de montaje
4 Tornillos para las agarraderas de montaje
2 Soportes de montaje
4 Tornillos para los soportes de montaje
1 157604171-001 Ensamblaje de rieles de montaje fijado a la izquierda
1 157604171-002 Ensamblaje de rieles de montaje fijado a la derecha
4 Tuercas sujetadoras 10-32
8 Tornillos de cabeza plana 10-321/22
2 157604172-001 Soporte de fijación posterior
4 Tornillo de cabeza fresada 10-321/22
1 164201357
Guía del usuario del juego de riel de 4 postes Powerware
1 05147305
Guía del usuario Powerware 5125 Dos en uno (1000–1500 VA)
1. Fije las agarraderas de montaje suministradas a los
soportes de montaje.
Alinee los soportes de montaje con los orificios de los
tornillos en la parte lateral del SIE y asegúrelos con
los tornillos que se proporcionan.
NOTA El SIE y los Módulos de batería extendida (EBMs)
opcional se TIENEN que instalar en la base del estante. Si se
colocan en un estante con equipo existente, el estante se
debe configurar de nuevo para permitir la instalación del SIE
en la base del mismo.
NOTA Los EBMs se deben instalar bajo el SIE.
2. Instale las tuercas sujetadoras sobre los orificios en la
parte posterior del estante.
NOTA Las tuercas sujetadoras para el primer conjunto de
rieles van sobre los orificios en la posición 2 y 4. Si instala
rieles adicionales, el siguiente conjunto de tuercas
sujetadoras debe colocarse en los orificios 4 y 6 sobre la
última tuerca sujetadora que se instaló.
.
Posición 2
Posición 4
Posición 8
Posición 10
Segundo conjunto de
tuercas sujetadoras
Primer conjunto de
tuercas sujetadoras
22
Inicio rápido de Powerware
®
5125 (9910 P18) para aplicaciones de IBM
®
: 164201421 A
3. Asegure ambos rieles a la parte posterior del estante
con los tornillos de cabeza plana. Inserte los tornillos
através de las tuercas sujetadoras instaladas en el
Paso 2.
4. Asegure ambos rieles a la parte delantera del estante
con los tornillos de cabeza plana. Inserte los tornillos
a través de los orificios del centro del riel.
NOTA No apriete los tornillos hasta que haya instalado el
SIE o el EBM.
5. Coloque el SIE y cualquier EBMs opcional en el
estante.
PRECAUCIÓN
El SIE y el EBM son pesados. Se necesita como mínimo dos
personas para colocar el SIE en el estante.
6. Para asegurar la parte posterior del SIE al estante,
afloje la tuerca de mariposa en el soporte de fijación
posterior y deslice el soporte sobre la parte posterior
del SIE. Apriete la tuerca de mariposa.
7. Asegure la parte delantera del SIE al estante con los
tornillos de cabeza fresada.
Soporte de
fijación
posterior
23
Inicio rápido de Powerware
®
5125 (9910 P18) para aplicaciones de IBM
®
: 164201421 A
Paso 2. Conexiones de los cables
Cant. Número de parte
de Powerware
Descripción
2 60420055 IEC 320-C13 a Cables de potencia del equipo C14, 10A (1.8 m)
1 05147305
Guía del usuario Powerware 5125 Dos en uno (1000–1500 VA)
1. Si utiliza un bus de distribución de energía (BDE), conecte
el equipo a los receptáculos de salida de SIE adecuados,
utilizando los cables de interconexión que se
proporcionan con el estante IBM.
NOTA NO proteja impresoras láser con el SIE pues tienen
requisitos de energía excepcionalmente altos para los
elementos de calentamiento.
Si utiliza dos BDE para redundancia, conecte el equipo
como se muestra.
2. Conecte el cable de potencia de salida (IEC 320-C13
a C14) en el conector de salida en el panel posterior
del SIE.
3. Conecte el otro extremo del cable de potencia de
salida en el BDE.
NOTA Si utiliza más de un SIE en un estante, verifique que
los cables de potencia de salida del SIE estén conectados en
BDE separados.
Para obtener información adicional sobre la conexión del
estante P18, visite
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
4. Para completar la puesta en marcha, consulte la
Guía del usuario Powerware 5125 Dos en uno
(1000–1500 VA).
24
Inicio rápido de Powerware
®
5125 (9910 P18) para aplicaciones de IBM
®
: 164201421 A
Paso 3. Opciones de comunicación
Cant. Número de parte
de Powerware
Descripción
1 05146745-31 CD de Suite de software Powerware
1 124102022-002 SIE a Cables de comunicación del servidor (DB-9 a DB-9, 1.8 m)
Las siguientes opciones de comunicación se encuentran
disponibles con el SIE:
: Un servidor conectado en forma serial al SIE P18
: Red (WebServer) con el SIE P18 como un nodo
Para obtener información adicional, visite
www.oem.powerware.com/ibm-ups/pdf/p18details.pdf.
Servicio y soporte técnico
En los Estados Unidos y Canadá, llame al 1-800-IBMSERV
(1-800-426-7378). En Europa, el Medio Oriente y África
(EMEA); Latinoamérica o Asia Pacífico, llame a las
oficinas
de IBM
, las cuales proporcionan servicio a su cuenta.

Transcripción de documentos

POWERWARE 5125 (9910 P18) QUICK START FOR IBM APPLICATIONS NOTE The following procedure is for an IBM9 pSeriesZ rack only. If you have another type of rack, contact your service representative (see page 4). Step 1. UPS Setup 1. Qty. Powerware Part Number Description 2 — Mounting Handles 4 — Mounting Handle Screws 2 — Mounting Brackets 4 — Mounting Bracket Screws 1 157604171-001 Left Fixed Mounting Rail Assembly 1 157604171-002 Right Fixed Mounting Rail Assembly 4 — 10-32 Clip Nuts 8 — 10-321/22 Pan-Head Screws 2 157604172-001 4 — 1 164201357 Powerware 4-Post Rail Kit User’s Guide 1 05147305 Powerware 5125 Two-in-One (1000–1500 VA) User’s Guide Rear Hold-Down Brackets 10-321/22 Flat-Head Screws Attach the supplied mounting handles to the mounting brackets. Align the mounting brackets with the screw holes on the side of the UPS and secure with the supplied screws. NOTE The UPS and Extended Battery Modules MUST be installed at the bottom of the rack. If placed in a rack with existing equipment, the rack must be reconfigured to allow the UPS installation at the bottom of the rack. NOTE The EBMs must be installed below the UPS. Position 10 Second Set of Clip Nuts 2. Install the clip nuts over the holes on the back of the rack. Position 8 NOTE The clip nuts for the first set of rails go over the holes in position 2 and 4. If you are installing additional rails, the next set of clip nuts should be placed 4 and 6 holes above the last installed clip nut. Position 4 Powerware® 5125 (9910 P18) Quick Start for IBM® Applications : 164201421 A First Set of Clip Nuts Position 2 1 3. Secure both rails to the back of the rack with pan-head screws. Insert the screws through the clip nuts installed in Step 2. 4. Secure both rails to the front of the rack with pan-head screws. Insert the screws through the center holes of the rail. NOTE Do not tighten the screws until the UPS or EBM is installed. 5. Slide the UPS and any optional EBMs into the rack. CAUTION The UPS and EBM are heavy. A minimum of two people are required to lift the UPS into the rack. 6. 7. 2 To secure the back of the UPS to the rack, loosen the wing nut on the rear hold-down bracket and slide the bracket over the rear of the UPS. Tighten the wing nut. Rear Hold-Down Bracket Secure the front of the UPS to the rack using flat-head screws. Powerware® 5125 (9910 P18) Quick Start for IBM® Applications : 164201421 A Step 2. Cord Connections 1. Qty. Powerware Part Number Description 2 60420055 IEC 320-C13 to C14, 10A Equipment Power Cords (6 ft/1.8m) 1 05147305 Powerware 5125 Two-in-One (1000–1500 VA) User’s Guide If you are using a power distribution bus (PDB), plug the equipment into the appropriate UPS output receptacles using the interconnect cords supplied with the IBM rack. NOTE DO NOT protect laser printers with the UPS because of the exceptionally high power requirements of the heating elements. If you are using two PDBs for redundancy, plug in the equipment as shown. 2. Plug the output power cord (IEC 320-C13 to C-14) into the output connector on the UPS rear panel. 3. Plug the other end of the output power cord into the PDB. NOTE If you are using more than one UPS in a rack, verify that the UPS output power cords are plugged into separate PDBs. For additional P18 rack connection information, go to www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. To complete startup, refer to Powerware 5125 Two-in-One (1000–1500 VA) User’s Guide. Powerware® 5125 (9910 P18) Quick Start for IBM® Applications : 164201421 A 3 Step 3. Communication Options Qty. Powerware Part Number 1 05146745-31 1 124102022-002 Description Powerware Software Suite CD UPS to Server Communication Cables (DB-9 to DB-9, 6 ft/1.8m) The following communication options are available with the UPS: : One server serially connected to the P18 UPS : Network (WebServer) with the P18 UPS as a node For additional information, go to www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Service and Support In the United States and Canada, call 1-800-IBMSERV (1-800-426-7378). In Europe, the Middle East, and Africa (EMEA); Latin America; or Asia-Pacific, call the IBM office that services your account. 4 Powerware® 5125 (9910 P18) Quick Start for IBM® Applications : 164201421 A GUIDE DE DÉMARRAGE RAPIDE POWERWARE 5125 (9910 P18) POUR APPLICATIONS IBM REMARQUE La procédure suivante s’applique à une baie IBM9 pSeriesZ uniquement. Pour tout autre type de baie, contactez votre représentant du service (voir page 8). Etape 1. Installation de l’onduleur 1. Qté Numéro de pièce Powerware Description 2 — Poignées de montage 4 — Vis de poignées de montage 2 — Supports de fixation 4 — Vis de supports de fixation 1 157604171-001 Ensemble de rails de montage fixes de gauche 1 157604171-002 Ensemble de rails de montage fixes de droite 4 — Ecrous de clips 10-32 8 — 10-321/22 Vis à tête cylindrique large 2 157604172-001 4 — 1 164201357 Guide de l’utilisateur de l’ensemble de rails pour 4 postes Powerware 1 05147305 Guide de l’utilisateur Powerware 5125 deux en un (1000–1500 VA) Supports de fixation arrière 10-321/22 Vis à tête plate Fixez les poignées de montage fournies aux supports de fixation. Alignez les supports de fixation avec les trous pour vis sur la face latérale de l’onduleur et fixez les supports à l’aide des vis fournies. REMARQUE L’onduleur et tout Module de batterie étendu (EBM) optionnels DOIVENT être installés dans le fond de la baie. Si la baie contient déjà des appareils, elle doit être réorganisée afin de permettre l’installation de l’onduleur au fond de la baie. REMARQUE Les EBM doivent être installés sous l’onduleur. 2. Posez les écrous de clips sur les trous à l’arrière de la baie. REMARQUE Posez les écrous de clips du premier ensemble de rails sur les trous des positions 2 et 4. Si vous installez d’autres rails, le prochain ensemble d’écrous de clips doit être placé 4 et 6 trous au-dessus du dernier écrou de clip posé. Guide de démarrage rapide Powerware® 5125 (9910 P18) pour applications IBM® : 164201421 A Position 10 Position 8 Position 4 Position 2 Second ensemble d’écrous de clips Premier ensemble d’écrous de clips 5 3. Fixez les deux rails à l’arrière de la baie à l’aide de vis à tête cylindrique large. Insérez les vis dans les écrous de clips posés à l’étape 2. 4. Fixez les deux rails à l’avant de la baie à l’aide de vis à tête cylindrique large. Insérez les vis dans les trous centraux du rail. REMARQUE Ne serrez les vis que lorsque l’onduleur ou l’EBM est installé. 5. Insérez l’onduleur et les EBM optionnels dans la baie. ATTENTION L’onduleur et l’EBM sont lourds. Deux personnes au minimum sont requises pour soulever l’onduleur et le placer dans la baie. 6. 7. 6 Pour fixer l’arrière de l’onduleur à la baie, desserrez l’écrou papillon du support de fixation arrière et faites glisser le support par-dessus l’arrière de l’onduleur. Serrez l’écrou papillon. Support de fixation arrière Fixez l’avant de l’onduleur à la baie à l’aide de vis à tête plate. Guide de démarrage rapide Powerware® 5125 (9910 P18) pour applications IBM® : 164201421 A Etape 2. Connexion des cordons 1. Qté Numéro de pièce Powerware Description 2 60420055 Cordons d’alimentation pour appareils IEC 320-C13 vers C14, 10A (1,8m) 1 05147305 Guide de l’utilisateur Powerware 5125 deux en un (1000–1500 VA) Si vous utilisez un bus de distribution d’alimentation (PDB), raccordez vos appareils aux prises de sortie correspondantes de l’onduleur UPS à l’aide des cordons de raccordement fournis avec la baie IBM. REMARQUE NE PAS protéger les imprimantes laser avec l’onduleur car les besoins en énergie des éléments chauffants sont exceptionnellement élevés. Si vous utilisez deux PDB pour la redondance, raccordez-les aux appareils comme indiqué. 2. Branchez le cordon d’alimentation de sortie (IEC 320-C13 vers C-14) sur le connecteur de sortie du panneau arrière de l’onduleur UPS. 3. Branchez l’autre extrémité du cordon de sortie dans le PDB. REMARQUE Si vous utilisez plusieurs onduleurs dans une baie, vérifiez que les cordons d’alimentation de sortie des onduleurs sont raccordés à des PDB distincts. Pour des informations supplémentaires sur le raccordement de la baie au P18, consultez le site www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. Pour effectuer la mise en route, voir Guide de l’utilisateur Powerware 5125 deux en un (1000–1500 VA). Guide de démarrage rapide Powerware® 5125 (9910 P18) pour applications IBM® : 164201421 A 7 Etape 3. Options de communication Qté Numéro de pièce Powerware 1 05146745-31 1 124102022-002 Description CD de la Suite logicielles Powerware Câbles de communication Onduleur vers Serveur (DB-9 vers DB-9, 1,8m) Options de communication disponibles avec l’onduleur : : Un serveur branché en série à l’onduleur UPS P18 : Réseau (WebServer) avec onduleur P18 en guise de noeud Pour des informations supplémentaires, consultez le site www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Service après-vente et assistance technique Aux Etats-Unis et au Canada, appelez le 1-800-IBMSERV (1-800-426-7378). En Europe, au Moyen-Orient, en Afrique, en Amérique latine ou en Asie-Pacifique, appelez le centre IBM qui est responsable de votre compte. 8 Guide de démarrage rapide Powerware® 5125 (9910 P18) pour applications IBM® : 164201421 A POWERWARE 5125 (9910 P18) SCHNELLE INBETRIEBNAHME FÜR IBM-ANWENDUNGEN HINWEIS Das folgende Verfahren bezieht sich nur auf ein Gestell des Typs IBM9 pSeriesZ . Wenn Sie eine andere Art von Gestell verwenden, wenden Sie sich an Ihren Kundendienstmitarbeiter (siehe Seite 12). Schritt 1: Einrichten der USV 1. Menge Powerware Teilenummer Bezeichnung 2 — Montagegriffe 4 — Schrauben für Montagegriffe 2 — Halterungen 4 — Schrauben für Halterungen 1 157604171-001 Links montierter Befestigungsschienensatz 1 157604171-002 Rechts montierter Befestigungsschienensatz 4 — 10-32 Clipsmuttern 8 — 10-321/22 Flachkopfschrauben 2 157604172-001 4 — 1 164201357 Benutzerhandbuch für Powerware Schienensatz für 4 Stützpfosten 1 05147305 Benutzerhandbuch für Powerware 5125 Two-in-One (1000 – 1500 W) Hintere Haltebügel 10-321/22 Senkkopfschrauben Mitgelieferte Montagegriffe an den Halterungen montieren. Die Halterungen nach den Schraubenlöchern auf der Seite der USV ausrichten und mit den mitgelieferten Schrauben sichern. HINWEIS Die USV und die optionale Erweiterte Batteriemoduls (EBMs) MÜSSEN unten in das Gestell eingebaut werden. Beim Einbau in ein Gestell mit vorhandenen Geräten ist das Gestell so zu konfigurieren, daß der Einbau der USV unten in das Gestell möglich ist. HINWEIS Die EBMs müssen unter dem USV installiert werden. 2. Bringen Sie die Clipsmuttern über den Bohrungen auf der Rückseite des Gestells an. HINWEIS Die Clipsmuttern für den ersten Schienensatz gehören über die Bohrungen in Position 2 und 4. Sind weitere Schienen zu installieren, muss der nächste Satz Clipsmuttern 4 und 6 Bohrungen über der letzen montierten Clipsmutter platziert werden. Powerware® 5125 (9910 P18) Schnelle Inbetriebnahme für IBM®-Anwendungen : 164201421 A Position 10 Position 8 Position 4 Position 2 Zweiter Satz Clipsmuttern Erster Satz Clipsmuttern 9 3. Beide Schienen an der Rückseite des Gestells mit Flachkopfschrauben befestigen. Die Schrauben durch die in Schritt 2 installierten Clipsmuttern einfügen. 4. Beide Schienen an der Vorderseite des Gestells mit Flachkopfschrauben befestigen. Die Schrauben durch die mittleren Bohrungen der Schiene stecken. HINWEIS Die Schrauben nicht anziehen, bevor die USV bzw. das EBM montiert ist. 5. Die USV und etwaige optionale EBMs in das Gestell schieben. ACHTUNG Die USV und das EBM sind schwer. Zum Hineinheben der USV in das Gestell sind mindestens zwei Personen erforderlich. 6. 7. 10 Zur Befestigung der Rückseite der USV im Gestell Flügelmutter am hinteren Haltebügel lösen und den Bügel über die Rückseite der USV schieben. Flügelmutter anziehen. Hinterer Haltebügel Vorderseite der USV mit Senkkopfschrauben am Gestell befestigen. Powerware® 5125 (9910 P18) Schnelle Inbetriebnahme für IBM®-Anwendungen : 164201421 A Schritt 2: Kabelanschlüsse 1. Menge Powerware Teilenummer Bezeichnung 2 60420055 Gerätestromkabel (1,8m) von IEC 320-C13 zu C14, 10A 1 05147305 Benutzerhandbuch für Powerware 5125 Two-in-One (1000 – 1500 W) Wenn Sie einen Stromverteilungsbus (PDB) verwenden, schließen Sie das Gerät am entsprechenden Ausgangsanschluss der USV an, indem Sie die mit dem IBM-Gestell gelieferten Verbindungskabel verwenden. HINWEIS Laserdrucker wegen des außerordentlich hohen Leistungsbedarfs der Heizelemente NICHT mit der USV schützen. Wenn Sie aus Redundanzgründen zwei PDBs verwenden, schließen Sie die Geräte gemäß der Abbildung an. 2. Das Netzausgangskabel (IEC 320-C13 zu C-14) in den Ausgangsanschluss auf der Rückwand der USV stecken. 3. Das andere Ende des Netzausgangskabels in den PDB stecken. HINWEIS Wenn mehrere USVs in einem Gestell verwendet werden, ist zu prüfen, dass die Netzausgangskabel der USVs an separaten PDBs angeschlossen sind. Weitere Informationen zum Anschluss von P18-Gestellen finden Sie unter www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. Informationen zum Abschließen der Inbetriebnahme finden Sie im Benutzerhandbuch für Powerware 5125 Two-in-One (1000 – 1500 W). Powerware® 5125 (9910 P18) Schnelle Inbetriebnahme für IBM®-Anwendungen : 164201421 A 11 Schritt 3: Kommunikationsoptionen Menge Powerware Teilenummer Bezeichnung 1 05146745-31 CD mit der Powerware Software-Reihe 1 124102022-002 Datenübertragungskabel USV-Server (DB-9 zu DB-9, 1,8m) Die folgenden Kommunikationsoptionen sind für die USV verfügbar: : Ein seriell am USV P18 angeschlossener Server : Netzwerk-Server (Web-Server) mit USV P18 als Knoten Weitere Informationen finden Sie unter www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Kundendienst und Unterstützung Rufen Sie in den Vereinigten Staaten und in Kanada 1-800-IBMSERV (1-800-426-7378) an. In Europa, im Nahen Osten und in Afrika (EMEA) sowie in Lateinamerika oder in Asien/im Pazifikraum rufen Sie das IBM-Büro an, das für Ihr Konto zuständig ist. 12 Powerware® 5125 (9910 P18) Schnelle Inbetriebnahme für IBM®-Anwendungen : 164201421 A POWERWARE 5125 (9910 P18) GUIDA RAPIDA PER LE APPLICAZIONI IBM NOTA La procedura descritta di seguito si riferisce solo ai rack IBM9 pSeriesZ . Per rack di tipo diverso, è necessario rivolgersi al il vostro rappresentante per l’assistenza (vedere la pagina 16). Passo 1. Installazione dell’UPS 1. Qtà Powerware numero parte Descrizione 2 — Maniglie per il montaggio 4 — Viti per le maniglie per il montaggio 2 — Staffe il montaggio 4 — Viti per le staffe il montaggio 1 157604171-001 Guida di montaggio fissa sinistra 1 157604171-002 Guida di montaggio fissa destra 4 — Dadi di fermo 10-32 8 — Viti con testa universale 10-321/22 2 157604172-001 4 — 1 164201357 Kit Powerware 4, manuale per l’utente 1 05147305 Powerware 5125 Due in uno (1000–1500 VA) Manuale dell’utente Staffe di bloccaggio posteriori Viti con testa piatta 10-321/22 Collegare le maniglie di montaggio fornite alle staffe di montaggio. Allineare le staffe di montaggio con i fori delle viti sul lato dell’UPS e serrarle con le viti fornite in dotazione. NOTA L’UPS e i Moduli batteria di espansione opzionale DEVONO essere installati nella sezione inferiore del rack. Se il rack contiene già altre attrezzature, è necessario riconfigurarlo in modo da consentire l’installazione dell’UPS nella sezione inferiore del rack. NOTA Gli EBM devono essere installati sotto l’UPS. 2. Inserire i dati di fermo nei fori sul retro del rack. Posizione 10 Secondo gruppo di dadi Posizione 8 NOTA I dadi di fermo per il primo gruppo di guide devono essere inseriti nei fori corrispondenti alle posizioni 2 e 4. Se si installano guide aggiuntive, installare i dadi di fermo aggiuntivi nei fori corrispondenti alle posizioni 4 e 6, sopra l’ultimo dado di fermo installato. Powerware® 5125 (9910 P18) Guida rapida per le applicazioni IBM® : 164201421 A Posizione 4 Primo gruppo di dadi Posizione 2 13 3. Bloccare entrambe le guide sul retro del rack utilizzando le viti a testa universale. Inserire le viti nei dadi di fermo installati nel punto 2. 4. Bloccare entrambe le guide sul lato frontale del rack utilizzando le viti a testa universale. Inserire le viti nei fori centrali della guida. NOTA Serrare le viti solo dopo aver installato l’UPS o l’EBM. 5. Far scorrere l’UPS e tutti gli EBM opzionali nel rack. ATTENZIONE L’UPS e l’ EBM ssono pesanti. Per spostare l’UPS è richiesto l’intervento di almeno due persone. 6. 7. 14 Per bloccare il retro dell’UPS sul rack, allentare il dado ad alette sul retro della staffa di bloccaggio e far scorrere la staffa sul retro dell’UPS. Serrare il dado ad alette. Staffa di bloccaggio posteriore Bloccare il lato frontale dell’UPS sul rack utilizzando le viti a testa piatta. Powerware® 5125 (9910 P18) Guida rapida per le applicazioni IBM® : 164201421 A Passo 2. Connessione dei cavi 1. Qtà Powerware numero parte Descrizione 2 60420055 Cavi di alimentazione apparecchiatura da IEC 320/C13 a C14, 10E (1,8 metri) 1 05147305 Powerware 5125 Due in uno (1000–1500 VA) Manuale dell’utente Se si utilizza un bus per la distribuzione dell’alimentazione (PDB), è necessario collegare l’attrezzatura alla presa di uscita dell’UPS appropriata utilizzando i cavi di interconnessione forniti con il rack. NOTA NON proteggere le stampanti laser con l’UPS a causa della potenza estremamente elevata richiesta dagli elementi riscaldanti. Se si utilizzano due PDB a scopo di ridondanza, effettuare le connessioni come mostrato nella figura. 2. Collegare il cavo di alimentazione in uscita (da IEC 320-C13 a C-14) al connettore in uscita sul pannello posteriore dell’UPS. 3. Collegare l’altra estremità del cavo di alimentazione in uscita nel PDB. NOTA Se si utilizzano più UPS sul rack, verificare che i cavi di alimentazione in uscita dell’UPS siano collegati a PDB diversi. Per ulteriori informazioni sulla connessione dei rack P18, visitare il sito Web www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. Per completare l’installazione, consultare la Powerware 5125 Due in uno (1000–1500 VA) Manuale dell’utente. Powerware® 5125 (9910 P18) Guida rapida per le applicazioni IBM® : 164201421 A 15 Passo 3. Opzioni per le comunicazioni Qtà Powerware numero parte 1 05146745-31 1 124102022-002 Descrizione CD contenente il pacchetto software Powerware Cavi di comunicazione da UPS al server (DB-9/DB-9, 1,8 metri) Per l’UPS sono disponibili le seguenti opzioni di comunicazione: : Un server collegato all’UPS P18 tramite linea seriale : Rete (WebServer) con l’UPS P18 utilizzato come nodo Per ulteriori informazioni, consultare il sito Web www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Assistenza e supporto Per gli Stati Uniti e Canada, chiamare il numero 1-800-IBMSERV (1-800-426-7378). In Europa, Medio Oriente e Africa (EMEA), America Latina, o Asia del Pacifico, chiamare il numero Ufficio IBM, per l’assistenza clienti. 16 Powerware® 5125 (9910 P18) Guida rapida per le applicazioni IBM® : 164201421 A POWERWARE 5125 (9910 P18) - GUIA RÁPIDO PARA APLICAÇÕES IBM OBSERVAÇÃO Os procedimentos a seguir se referem somente a chassi IBM9 pSeriesZ . Se você tiver outro tipo de chassi, contate a assistência técnica de sua região (consulte a página 20). Passo 1. Configuração do no-break Qtde. Número de referência Powerware Descrição 1. 2 — Alças de montagem 4 — Parafusos para alça de montagem 2 — Suportes de montagem 4 — Parafusos para suportes de montagem 1 157604171-001 Conjunto do trilho de montagem fixo à esquerda 1 157604171-002 Conjunto do trilho de montagem fixo à direita 4 — Porcas autotravantes 10-32 8 — Parafusos philips 10-321/22 2 157604172-001 Suportes de contenção traseiros 4 — 1 164201357 Guia do Usuário do Kit de 4 Colunas de Trilhos Powerware 1 05147305 Guia do Usuário do Powerware 5125 Two-in-One (1000–1500 VA) Parafusos de cabeça chata 10-321/22 Fixe as alças de montagem fornecidas aos suportes de montagem. Alinhe os suportes de montagem com os orifícios para parafusos na parte lateral do no-break e fixe-os com os parafusos fornecidos. OBSERVAÇÃO O no-break e os Módulos Estendidos de Baterias (EBMs) opcionais DEVEM ser instalados na parte inferior do chassi. Se forem instalados em um chassi que já contém algum equipamento, o chassi deverá ser reconfigurado para permitir a instalação do no-break na sua parte inferior. OBSERVAÇÃO Os EBMs devem ser instalados abaixo do no-break. 2. Posição 10 Instale as porcas autotravantes nos orifícios da parte de trás do chassi. OBSERVAÇÃO As porcas autotravantes destinadas ao primeiro conjunto de trilhos devem ser instaladas nos orifícios nas posições 2 e 4. Se você estiver instalando trilhos adicionais, o próximo conjunto de porcas autotravantes deverá ser instalado 4 e 6 orifícios acima da última porca instalada. Powerware® 5125 (9910 P18) - Guia Rápido para Aplicações IBM® : 164201421 A Posição 8 Posição 4 Posição 2 Segundo conjunto de porcas autotravantes Primeiro conjunto de porcas autotravantes 17 3. Fixe ambos os trilhos no fundo do chassi com parafusos philips. Rosqueie os parafusos através das porcas autotravantes instaladas no passo 2. 4. Fixe ambos os trilhos na parte frontal do chassi com parafusos philips. Rosqueie os parafusos através dos orifícios centrais do trilho. OBSERVAÇÃO Não aperte os parafusos até que o no-break ou o EBM esteja instalado. 5. Deslize o no-break e quaisquer EBMs opcionais para dentro do chassi. PERIGO O no-break e o EBM são pesados. São necessárias pelo menos duas pessoas para colocar o no-break no chassi. 6. 7. 18 Para fixar a parte de trás do no-break no chassi, afrouxe a porca borboleta no suporte traseiro e deslize este suporte sobre a parte traseira do no-break. Aperte a porca borboleta. Suporte de contenção traseiro Fixe a parte frontal do no-break no chassi usando parafusos de cabeça chata. Powerware® 5125 (9910 P18) - Guia Rápido para Aplicações IBM® : 164201421 A Passo 2. Conexões dos cabos Qtde. 1. Número de referência Descrição Powerware 2 60420055 Cabos de alimentação do equipamento IEC 320-C13 para C14, 10A, de 1,8 m 1 05147305 Guia do Usuário do Powerware 5125 Two-in-One (1000–1500 VA) Se você estiver usando um barramento de distribuição de energia (PDB - power distribution bus), conecte o equipamento aos receptáculos de saída apropriados usando os cabos de ligação fornecidos com o chassi IBM. OBSERVAÇÃO NÃO proteja impressoras laser com o no-break devido às exigências de energia excepcionalmente altas dos componentes de aquecimento. Se você estiver usando dois PDBs para conexões redundantes, conecte o equipamento conforme ilustrado. 2. Conecte o cabo de alimentação de saída (IEC 320-C13 a C-14) no conector de saída, que se encontra no painel traseiro do no-break. 3. Conecte a outra extremidade do cabo de alimentação de saída no PDB. OBSERVAÇÃO Se você estiver usando mais do que um no-break em um único chassi, certifique-se de que os cabos de alimentação de saída estejam conectados em PDBs separados. Para obter informações adicionais sobre conexões em chassi P18, visite www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. Para completar o procedimento de inicialização, consulte o Guia do Usuário do Powerware 5125 Two-in-One (1000–1500 VA). Powerware® 5125 (9910 P18) - Guia Rápido para Aplicações IBM® : 164201421 A 19 Passo 3. Opções de comunicação Qtde. Número de referência Powerware 1 05146745-31 1 124102022-002 Descrição CD-ROM do Pacote de Software Powerware Cabos de comunicação entre no-break e servidor (DB-9 para DB-9, 1,8 m) As seguintes opções de comunicação estão disponíveis com o no-break: : Um servidor conectado serialmente ao no-break P18 : Em rede (WebServer), com o no-break P18 como um dos nós Para obter informações adicionais, visite www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Assistência e suporte Nos Estados Unidos e no Canadá, ligue para 1-800-IBMSERV (1-800-426-7378). Na Europa, no Oriente Médio e na África (EMEA), na América Latina ou Ásia-Pacífico, entre em contato com o escritório IBM que lhe fornece assistência. 20 Powerware® 5125 (9910 P18) - Guia Rápido para Aplicações IBM® : 164201421 A INICIO RÁPIDO DE POWERWARE 5125 (9910 P18) PARA APLICACIONES DE IBM NOTA El siguiente procedimiento es solamente para un estante IBM9 pSeriesZ . Si tiene otro tipo de estante comuníquese con su representante de servicio (consulte la página 24). Paso 1. Configuración del SIE 1. Cant. Número de parte de Powerware Descripción 2 — Agarraderas de montaje 4 — Tornillos para las agarraderas de montaje 2 — Soportes de montaje 4 — Tornillos para los soportes de montaje 1 157604171-001 Ensamblaje de rieles de montaje fijado a la izquierda 1 157604171-002 Ensamblaje de rieles de montaje fijado a la derecha 4 — Tuercas sujetadoras 10-32 8 — Tornillos de cabeza plana 10-321/22 2 157604172-001 4 — 1 164201357 Guía del usuario del juego de riel de 4 postes Powerware 1 05147305 Guía del usuario Powerware 5125 Dos en uno (1000–1500 VA) Soporte de fijación posterior Tornillo de cabeza fresada 10-321/22 Fije las agarraderas de montaje suministradas a los soportes de montaje. Alinee los soportes de montaje con los orificios de los tornillos en la parte lateral del SIE y asegúrelos con los tornillos que se proporcionan. NOTA El SIE y los Módulos de batería extendida (EBMs) opcional se TIENEN que instalar en la base del estante. Si se colocan en un estante con equipo existente, el estante se debe configurar de nuevo para permitir la instalación del SIE en la base del mismo. NOTA Los EBMs se deben instalar bajo el SIE. 2. Instale las tuercas sujetadoras sobre los orificios en la parte posterior del estante. NOTA Las tuercas sujetadoras para el primer conjunto de rieles van sobre los orificios en la posición 2 y 4. Si instala rieles adicionales, el siguiente conjunto de tuercas sujetadoras debe colocarse en los orificios 4 y 6 sobre la última tuerca sujetadora que se instaló. Inicio rápido de Powerware® 5125 (9910 P18) para aplicaciones de IBM® : 164201421 A Posición 10 Posición 8 Posición 4 Posición 2 Segundo conjunto de tuercas sujetadoras Primer conjunto de tuercas sujetadoras 21 3. Asegure ambos rieles a la parte posterior del estante con los tornillos de cabeza plana. Inserte los tornillos a través de las tuercas sujetadoras instaladas en el Paso 2. 4. Asegure ambos rieles a la parte delantera del estante con los tornillos de cabeza plana. Inserte los tornillos a través de los orificios del centro del riel. NOTA No apriete los tornillos hasta que haya instalado el SIE o el EBM. 5. Coloque el SIE y cualquier EBMs opcional en el estante. PRECAUCIÓN El SIE y el EBM son pesados. Se necesita como mínimo dos personas para colocar el SIE en el estante. 6. 7. 22 Para asegurar la parte posterior del SIE al estante, afloje la tuerca de mariposa en el soporte de fijación posterior y deslice el soporte sobre la parte posterior del SIE. Apriete la tuerca de mariposa. Soporte de fijación posterior Asegure la parte delantera del SIE al estante con los tornillos de cabeza fresada. Inicio rápido de Powerware® 5125 (9910 P18) para aplicaciones de IBM® : 164201421 A Paso 2. Conexiones de los cables 1. Cant. Número de parte de Powerware Descripción 2 60420055 IEC 320-C13 a Cables de potencia del equipo C14, 10A (1.8 m) 1 05147305 Guía del usuario Powerware 5125 Dos en uno (1000–1500 VA) Si utiliza un bus de distribución de energía (BDE), conecte el equipo a los receptáculos de salida de SIE adecuados, utilizando los cables de interconexión que se proporcionan con el estante IBM. NOTA NO proteja impresoras láser con el SIE pues tienen requisitos de energía excepcionalmente altos para los elementos de calentamiento. Si utiliza dos BDE para redundancia, conecte el equipo como se muestra. 2. Conecte el cable de potencia de salida (IEC 320-C13 a C14) en el conector de salida en el panel posterior del SIE. 3. Conecte el otro extremo del cable de potencia de salida en el BDE. NOTA Si utiliza más de un SIE en un estante, verifique que los cables de potencia de salida del SIE estén conectados en BDE separados. Para obtener información adicional sobre la conexión del estante P18, visite www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. 4. Para completar la puesta en marcha, consulte la Guía del usuario Powerware 5125 Dos en uno (1000–1500 VA). Inicio rápido de Powerware® 5125 (9910 P18) para aplicaciones de IBM® : 164201421 A 23 Paso 3. Opciones de comunicación Cant. Número de parte Descripción de Powerware 1 05146745-31 1 124102022-002 CD de Suite de software Powerware SIE a Cables de comunicación del servidor (DB-9 a DB-9, 1.8 m) Las siguientes opciones de comunicación se encuentran disponibles con el SIE: : Un servidor conectado en forma serial al SIE P18 : Red (WebServer) con el SIE P18 como un nodo Para obtener información adicional, visite www.oem.powerware.com/ibm-ups/pdf/p18details.pdf. Servicio y soporte técnico En los Estados Unidos y Canadá, llame al 1-800-IBMSERV (1-800-426-7378). En Europa, el Medio Oriente y África (EMEA); Latinoamérica o Asia Pacífico, llame a las oficinas de IBM, las cuales proporcionan servicio a su cuenta. 24 Inicio rápido de Powerware® 5125 (9910 P18) para aplicaciones de IBM® : 164201421 A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Powerware 5125 9910 P18 Guía de inicio rápido

Tipo
Guía de inicio rápido